Loading...
HomeMy WebLinkAbout03-2057 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 2057 57 ssued: 5/071 Permit Type: GENERAL BUILDING PERMIT Class of Work: 434-ADD/AL T RESIDENTIAL Proposed Use: NOT APPLICABLE Sq. Feet: Est. Value: Cost: 1,360.87 Total Fees: Amount Paid: 40.00 Date Paid: I I 40.00! 5/07/2003 ress: 38706 ZEPHYRHILLS, FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 35-25-21-0010-1260-0140 Name: A TO Z ALUMINUM PRODUCT Addr: P.O. BOX 192 ZEPHYRHILLS, FL 33539 Phone: (813)715-7523 Lic: Work Desc: SCREEN ROOM A IA 38706 DAUGHTERY RD ZEPHYRHILLS, FL. 33541 Phone: ,J IJ3-10 .c,vt ,Ur..rH I S fL L1 H EL 1 N PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED LINTEL PRE-METER WATER FINAL MECHANICAL FRAME MISC SEWER MISC INSULATION WALL MISC MISC. MISC. INSULATION CEILING . MISC. MISC. MISC. DRIVEWAY J MISC. .. MISC. I FIRE DEPT. FINAL REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible _The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for- improvements to your property. If ou intend to obtain financing, consult with your lender or an attorney before recording our notice of co en cement. " --------~~~---~--_._.,_._-"_.._-- NO OCCUPANCY BEFORE C.O. .. ~ ---- TORS GNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS PERMIT APPLICATION BUILDING DBPARTMENT 5335 8~ STRBBT ZBPHYRHILLS, FL 33540 Phone:813-780-0020 Fax:813-780-0021 DATE RECEIVED 6' - '2 - () 3 PLANS REVIEW FBB PuJ Ui. '~1 ~cg 70,", S 7_ t\; {- L1 tIt~t '1J At,X-. H T (.:- rrt... (..{ fl... () OWNER I S NAME PHONE CONTACT '6( 3 -186 Z 77 ~ L-tJ t- M. (L( JOB SITE ADDRESS LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION PARCEL ID # '3 S- - 2- S- - z.. ( - 00 10 - I Z-G, 0 -0 N,:>( OBTAIN FROM PROPERTY TAX NOTICE) WORK PROPSED: [JNEW CONSTRUCTION [JSIGN ..ti:! ADDITION [JMOVE [JALTERATION [JREPAIR [J INSTALL [J DEMOLISH PROPOSED USE: [JSGL FAMILY DWELLING [JMULTI-FAMILY [J # OF UNITS [J MOBILE HOME ~THER [J COMMERCIAL [J INDUSTRIAL [J SWIMMING POOL CJ RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK I 5<:-./J2.. -e.-e.n ~ 3D HEIGHT / ,- 7-8' BUILDING SIZE 5 Xl&; SQUARE FOOTAGE RESIDENTIAL: COMMERCIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. [J BUILDING PERMITS REQUESTED 8' -, / 3 C. CJ, - VALUATION OF TOTAL CONSTRUCTION $ [J ELECTRICAL AMP SERVICE o FLORIDA POWER o W.R.E.C. [J PLUMBING o MECHANICAL $ VALUATION OF MECHANCIAL INSTALLATION o GAS [J ROOFING [J SPECIALTY [J OTHER TYPE OF CONSTRUCTION: [J BLOCK [J FRAME [J STEEL [J OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAO YES 0 NO BUILDBR L~ - COMPANY ~ h ;z. ~~;/1Vh'1 STATE CERT OR REG 1ST # C C- 12-:r cJ K" z.~ CITY PROCESSING # SIGNATURE ****************************************************************** BLBCTRICIAN COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ****************************************************************** PLUMBBR COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE MECHANICAL ****************************************************************** COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** OTHER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to ~deed restrictions". which may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-788-6611. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the ~Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhi1ls. C. TRANSPORTATION IMPACT FEES.AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of ~Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the ~owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the ~owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has comm~nced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone ~A" or ~A,etc.", it is understood that a drainage plan addressing a ~compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A ~NOTICE OF COMMENCEMENT". SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _ day of by acknowledged 1!L- STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _day of by acknowledged 19 (name of person acknowledged) Dwho is personally known to me, or (name of person acknowledged) [1ho is personally known to me, or o who has produced (type and whoD did Ddid not of identification) take an oath. o who has produced (type of identification) and who Ddid Diid not take an oath Signature of person taking acknowledgement Signature of person taking acknowledgment Name typed, printed or stamped Name typed, printed or stamped SITE !'loAN (RESIDENTIAL USE ONLY) PARCEL I.D. 3) SEC 25- TWP Zl RNG OOlD SUBD t~c BLOCK C! ('-(0 DATE: LOT Y;/l?/!,J I All drawings shall be drawn to scale or fully dimensioned for all parcels. ( 1 'I-v 11 ~ rJ\~(/ t;." (;, ~~ 0 j1" ~1Y /J D .v ( I { -- Aop :5'-.12 t-t: f\ I!-tn:~........ \ <g 11..1 II pJ2iUATE r<.(J- SHOW ALL EXISTING AND PROPOSED STRUCTURES GIVING DIMENSIONS AND SETBACKS. ALSO, INDICATE ANY BODIES OF WATER. TREES (INCLUDING SIZE, DIAMETER, TYPE), AND ROADWAYS (INCLUDING NAMES) ADJACENT TO THE PROPERTY. INDICATE THE SIZE, YEAR, AND NAME OF MOBILE; SUCH AS 12' X 60 I. 1981. FLEETWOOD. ALL "EASEMENTS", "PROPERTY LINES", "HIGIIT-OF-WAY", and "JURISDICTIONAL LINES" must be shown on all site plans. DO NOT ENCROACH INTO ANY EASEMENT WITH A STRUCTURE. HOUSE CONSTRUCTION rear (60') PRO POSE D ADDITION NoelLE HOlliE SET-UP re ar (80') rear (150' ) ~ '0 150' 40' (, ~ 8 II) a ~ II) 'Oe 25' ~ ~ ~ e::: - .~ . . 25' oM: Eai.'in. . .'! " " ~z " .. .. "; .. 8"." .. kl ~ C z: o ct o II: 50' ROAD NANE ROAD NANE ROAD NA NE PL PROPERTY LINE R/W = RlGIIT-OF-WAY o = TREES APPROVED SITE PLAN MUST BE POSTKD AT JOB LOCATI<It. NOTICE 01' DKKD RESTlUCTI(lII THIS PKRKIT may be subject to ''Deed Reatrictiorw" which are .,re reatrictive than County regulations. The permit holder as.u.ea reaporulibility for c~liancea with any applicable deed restrictions. site05:ce PC95035005/ A ! -S~ ~~ ~ \:--~ '-" - ~ ~ / / ~ ~ ~ ~ "::::.L~ ----I.. ~ ~ ~ l, y \.1) ~ ~\.J d)-:'(... '1 p~ x ~ UJ <'- ~ ~ ~ ~- 0 ~-.f) %'0 ~ ~ l~ ~ ~ ~ ~ ~~ '- -~ '" A~t7' ~~ .r.-;- :F' 1 fJ ~\ --- ~~ '-S\ " ::::::.z.. ~ SCREEN, VINYL, GLASS & MODULAR ROOMS INTERIOR BEAM TABLE 3.1.4 OR 3.1.5 ALUMINUM ROOF SYSTEM PER SECTION 7 SECTION 3 HOST STRUCTURE OR FOURTH WALL FRAME If' H .. ~ PANS OR PANELS CARRIER BEAM POST TYPICAL SLOPED SOLID ROOF ENCLOSURE SCALE: N.T.S. ALUMINUM ROOF SYSTEM PER SECTION 7 RIDGE BEAM (SEE TABLE 3.1.6 FOR SCREEN ROOMS OR TABLE 3.1.7 FOR GLASS ROOMS) HOST STRUCTURE OR FOURTH WALL FRAME .~r= r USE BEAM TO WALL DETAIL TYPICAL GABLE SOLID ROOF ENCLOSURE SCALE: NTS. Lawrence E. Bennett, P.E. CIVIL ENGINEER - DEVELOPMEfolT CONSUL T ANT P.O. BOX 4368, soum DAYTONA. FL32'21 TELEPHONE (386) 767-4774 FAX (386) 767-6556 SEAL @ COPYRIGHT 2002 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOllT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, PE PAGE 3-1 SCREEN, VINYL, GLASS & MODULAR ROOMS ROOF, COMPOSITE PANEL OR HOST STRUCTURAL FRAMING (4) #8 x 1/2" S.M.S. EACH SIDE OF POST 1 x 2 TOP RAIL FOR SIDE WALLS ONLY OR MIN. FRONT WALL 2 x 2 ATTACHED TO POST WI 1" x 1" x 2" ANGLE CLIPS EACH SIDE OF POST GIRT OR CHAIR RAIL AND KICK PLATE 2" x 2" x 0.032" MIN. HOLLOW RAIL ANCHOR 1 x 2 PLATE TO CONCRETE WITH 1/4" x 2-1/2" CONCRETE ANCHORS WITHIN 6" OF EACH SIDE OF EACH POST AT 24" O.C. MAX. OR THROUGH ANGLE AT 24" O.C. MAX. MIN. 3-1/2" SLAB 2500 PSI CONC. 6 x 6 - 10 x 10 WW.M. OR FIBER MESH / I SECTION 3 1" x 2" TOP RAILS FOR SIDE WALLS WITH MAX. 3.5' LOAD WIDTH SHALL HAVE A MAXIMUM UPRIGHT SPACING AS FOLLOWS WIND ZONE MAX. UPRIGHT SPACING 102 7'-0" 110 6'-7" 120 6'-3" 123 6~1" 130 5'-8" 140 5'-1" 150 4'-11" INTERNAL ORJiXTERNAl 'L' CLIP OR 'U' CHANNEL CHAIR RAIL ATTACHED TO POST WI MIN. (4) #10 S.M.S. 1 x 2 ORax 2 ATTACHED TO BOTTOM WI 1" x 1" x 2" x 1/16" 0.045" ANGLE CLIPS EACH SID AND MIN. (4) #10 x 1/2" S.M.S. 1" x 2" x 0.032" MIN. OPEN BAC EXTRUSION 1-1/8" MIN. IN CONCRETE VAPOR BARRIER UNDER CONCRETE POST TO BASE, GIRT AND POST TO BEAM DETAIL SCALE: 3" = 1 '-0" Lawrence E. Bennett, P.E. CML ENGINEER. DEVELOPMEMT CONSUL rANT PO BOX 4368. SOUTH DAYTONA. FL 32121 TELEPHONE (386) 767-4774 FAX (386) 767-6556 SEAL PAGE @ COPYRIGHT 2002 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOVT Tl-iE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. PE 3-11 SECTION 3 SCREEN. VINYL, GLASS & MODULAR ROOMS Table 3.1.1-110 Allowable Edge Beam Spans - Hollow Extrusions For Screen or Vinyl Rooms I Open or Partially Enclosed Structures For 3 second wind gust at 110 MPH velocity; using design load of 19 #/SF (32 #/SF for Max. Cantilever) Aluminum AHOY 6063 T-6 2" x 2" x 0.0""" ~.2"'If,O. 05lli" .-; Load Max. Span 1.'1 (bendlna"l)' or defl_ctlon 'd1 Load Max. SDan 'L' Ilbendlng 'b' or deflection 'cr) Width (ft.) 1 & 2 Span 3 Span 4 Span Max. Width (ft.) 1 &2 Span 3 Span 4 Span Max. Cantilever Cantilever 5 4'-4" d 5'-4" b 5'-2" b 1'.1" d 5 4'.r d 5'-8" d s'-r b 1'.2' d 6 4'.1" d 4'-10" b 4'-8" b 1'.{)" d 6 4'-4" d 5'-3" b 5'.1" b 1'-1" d 7 3'-10" d 4'-6" b 4'-4" b 0'-11" d 7 4'.1" d 4'-11" b 4'.9" b 1'.{)" d 8 3'-8" d 4'.2" b 4'.1" b 0'-11" d 8 3'-11" d 4'-'- b 4'-5" b 0'.11" d 9 3'-6" b 3'-11" b 3'-10" b 0'-11" d 9 3'.9" ;j 4'-4" b 4'-2" b 0'-11" d 10 3'-4" b 3'.9" b 3'-8" b 0'-10" d 10 3'-r d 4'-1" b 3'-11" b 0'-11" d 11 3'.2" b 3'-r b 3'-5" b 0'-10" d 11 3'-6" b 3'-11" b 3'-9" b 0'-10" d 12 3'-1" b 3'-5" b 3'-4" b 0'-10" d 12 3'-4" b 3'-g- b 3'-r b 0'.10" d 3" x 2" x 0.045" 3" x 2" x 0.070" Load Max. Span 1.' I (bending "I)' or deflection 'd1 Load Max. Span 'L'I (bending 'b' or deflection 'cr) Width (ft.) 1 & 2 Span 3 Span 4 Span Max. Width (ft.) 1 & 2 Span 3 Span 4 Span Max. Cantilever Cantilever 5 4'-9" d 5'-10" d 5'-11" b 1'-2" d 5 5'-8" d 6'-11" d 7'-1" d 1'-5" d 6 4'-6" d 5'-6" d 5'-5" b 1'-1" d 6 5'-4" d 6'-r d 6'-8" d 1'-4" d 7 4'-3" d 5'-2" b 5' .{)" b 1'-1" d 7 5'-1" d 6'-3" d 6'-4" d 1'-3" d 8 4'-1" d 4'-10" b 4'-8" b 1'.{)" d 8 4'-10" d 5'-11" d 6'-1" b 1'-2" d 9 3'-11" d 4'.r b 4'-5" b 0'-11" d 9 4'-8" d 5'-9" d 5'-8" b 1'-2" d 10 3'.9" d 4'-4" b 4'-2" b 0'-11" d 10 4'-6" d 5'-6" d 5'-5" b 1'-1" d 11 3'-8" d 4'.2" b 3'-11" b 0'-11" d 11 .4'-4" d 5'-4" b 5'-2" b 1'-1" d 12 3'-r b 3'-11" b 3'-10" b 0'-11" d 12 4'-3" d 5'-1" b 4'-11" b 1'-1" d 2" x 3" x 0.045" Load Max. Span 1.' I (bending "I)' or deflection 'd1 Load Max. Span 1.'/ (bending 'b' or deflection 'en Width (ft.) 1 &2Span 3 Span 4 Span Max. Width (ft.) 1 &2Span 3 Span 4 Span Max. Cantilever CantJlever 5 5'-11" d 6'.11" b 6'-9" b 1'-6" d 5 8'-1" d 9'-r b 9'-3" b 2'.{)" d 6 5'-r d 6'-5" b 6'-2" b 1'-5" d . 7'-r d 8'-9" b 8'-5" b 1'-11" d 7 5'-3" b 5'-11" b 5'-9" b 1'-4" d 7 7'-3" d 8'-1" b 7'-10" b 1'.10" d 8 4'-11" b 5'-6" b 5'-4" b 1'-3" d 8 6'-9" b 7'-r b 7'-4" b 1'-9" d 9 4'-8" b 5'-3" b 5' .{)" b 1'-3" d II 6'-5" b 7'-2" b .6'-11" b 1'-8" d 10 4'-5" b 4'-11" b 4'-9" b 1'-2" d 10 6'-1" b 6'-g" b 6'-r b 1'-r d 11 4'-3" b 4'.9" b 4'-r b 1'-2" d 11 5' -g" b 6'-5" b 6'-3" b 1'-7" d 12 4'.{)" b 4'-6" b 4'-4" b 1'-1" d 12 5'-6" b 6'-2" b 5'-11" b 1'-6" d Note: 1. Above spans do not Include length of knee brace. Add.horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 2. Spans may be Interpolated. Lawrence E. Bennett, P.E. CML ENGINEER. DEVELOPMENT CONSUL rANT P.O. BOX 4368. SOUlli DAYTONA. Fl32121 TELEPHONE (386) 767~774 FAX (386) 767~556 SEAL PAGE 3-26 @ COPYRIGHT 2002 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOlJT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. . . SECTION 5 ROOF OVER SYSTEMS I ~ L f I ! ~ - I 1 12. 1 12" x VARIOUS HEIGHT 5 RIB RISER ROOF PANEL SCALE: 3. = 1'-0" I Table 5.2.1 Allowable Spans for Pans for Roof Overs Metals USA, Building Products Southeast, Inc. Manufacturer'. Proprietary Sections: Aluminum Alloy 6105 H-28 I 1.1/4" x 12" x 0.026- 2 or 5 Rib Riser Panels 1-1/4" x 12. x 0.032" 2 or 5 Rib RIser Panels Wind Maximum Allowable Span Wind Maximum Allowable Span I Region 1 & 2 3 .. Max Region 1&2 3 4 Max i Span Span Span Cantilever Span Span Span Cantflever I 100 M.P.H. 4'.2. 5'.2- 5'.3- 2'-0- 100 M.P.H. 4'-r 5'-8- 5'-10" 2'-3" 110 M.P.H. 3'-11' 4'-10" 4 '-11" 1'-11" 110 M.P.H. 4'-4" 5''''" 5'.5" 2'-1" I 120 M.P.H. 3'-8' 4'-6" 4'-8" 1'.9" 120 M.P.H. 4'-1" 5'-0" 5'-2" 1'-11" I I 123 M.P.H. 3'.7" 4'-6" 4'-r 1'-9- 123 M.P.H. 4'-0" 4'-11" 5'-1" 1 '-11" I 130 M.P.H. 3'-6' 4'-4" 4'-S" 1'-8" 130 M.P.H. 3'-10" "'.g" 4'-10" 1 '-11" 1 040 M.P.H. 3'-4' 4'-1" 4'-2"' 1'.r 1040 M.P.H. 3'-8" 4'-r 4'.8" 1'-9" 150 M.P.H. 3'.2" 3'.11" 3'-11" 1'.0- 150 M.P.H. 3...,se 4'-4" 4'-5" 1'-8" 3. x 12" x 0.026" 2 or 5 Rib Riser Panels 3- x 12- x 0.032- 2 or 5 Rib RI.er Panels Wind Maximum Allowable Span Wind Maximum Allowable Span Region 1 & 2 3 4 Max Region 1&2 3 4 Max Span Span Span Cantilever Span Span Span Cantilever 100 M.P.H. 9'-10" 13'-3" 13'-6" 4'-0" 100 M.P.H. 10'-8" 10'-1" 15'-r 4'-0" 110 M.P.H. 9'.3' 12'-5" 12'-8" 4'-0" f10 M.P.H. 9'-11" g'-6" 14'.2"' 4'-0" 120 M.P.H. 8'.9' 10'-9" 10'-11" 4'-0" 120 M.P.H. 9'-5" 8'-11" 13'-5" 4'-0" 123 M.P.H. a'-7" 10'-r 10'-10" 3'-11" 123 M.P.H. 9' -J" 8'-9" 13'.2" 4'-0" 130 M.P.H. 8'-3" 10'-J" 10'-5" 3'-10" 130 M.P.H. 8'.11" 8'-6" 12' -g" 4'-0" 1040 M.P.H. 7'.10" 9'-9" 9'-11" 3'-8" 140 M.P.H. 8...,se 8'-1" 12'-5" 3'-11" 150 M.P.H. 7'.2" 9'-3" g'-6" 3'-6" 150 M.P.H. 8'-1" 11'-10" 11'-10" 3'-9" Note: Spans may be interpolated. Lawrence E. Bennett. P.E. EffiETAlS USA™ CML ENGINEER. DEVELOPMENT CONSUL TANT Building Products southeast, Inc. PO BOX 436/3, SOUTH DAYTONA. FL32121 1107 NORTH THOMAS RO., LEESBURG, FL 34748 7ElEPHONE (386) 767-4774 TEL: (352) 787-7766 FAX: (352) 787-4517 FAX (386) 767-6556 FLORIDA 1-800-342-9077 NATIONAL 1-800-874-0002 SEAL PAGE @ COPYRIGHT 2002 ! 5"20 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOVT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. SECTION 2 ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS TOP OF GRADE COMPACTED BACK FILL - "t" IS THICKNESS OF REQUIRED POST 3~ x 3~ POST (SEE TABLE) (2) 2~ x 2" x "t" ANGLE OR (1) U CHANNEL x "t" 3/S" x 3-112" BOLT SO LB. 2500 PSI CONCRETE PRE-MIX 3" EXTRUDED ALUMINUM BAS ALUMINUM POST AND BURIED FOOTING CONNECTION SCALE: 1-112" = 1'-0" POST IN CONCRETE #40 BAR 12" LONG POURED CONCRETE (REFER TO TABLE 2.4) ( o ~ ~ ~ > ~"" 3" x 3" POST TURN BOLTED" T ANCHOR RISER 2-3/4" x 2-3/4" x 2-1/2" LONG x 1/S" TUBING WELDED CONNECTION FAS.TEN (SEE SECTION 9) 12" x 12" x 1/4" PLATE 3-1/2" CONC. SLAB .. POST MAY BE FILLET WELDED DIRECTlY TO BASE PLATE ISOLATED FOOTING SCALE: 3" = 1'-0" BASE ANCHOR CONNECTOR FOR POST TO SLAB CONNECTION SCALE: 3" = 1'-0" Lawrence E. Bennett, P.E. CML aI!;/NEER - DEVELOPMENr CONSut. TANT P.O. BOX 4368, SOUTH DAYTONA,. FL 32121 TElEPHONE (386) 7ffT~n4 FAX (386) 7ffT~ SEAL PAGE @ COPYRIGHT 2002 2-22 NOT TO BE REPRODUCED IN WHOlE OR IN PART WITHOUT THE WRI1TEN PERMISSION OF LAWRENCE E. BENNETT. P.E. . ATTACHED & FREE-5TANDING COVERS AND UTILITY SHEDS SECTION 2 Table 2.3 Schedule of Post to Beam Size and Number of Thru-Bolts Required Aluminum Alloy 6063 T.(j Beam Minimum I # Thru-Bolts ti! L-D+V." Minimum M.inlmum # Size Post Size 1/4- . I 318- . Knee Brace" Knee Brace Screws Hollow Sections 2" x 3" x 0.050- Hollow Tlltl3" x 3"x 0.060" Scalloped I 2 I - 2" x 3" x 0.050" I (3)#8 1~'.,4".~~'''''''.........l3" ,,'It" xOJKiO"~ I 2 I - I 2" x 3" x 0.050" I (3) #8 Self Mating Beams 2" x 4" x 0.038- X 0.100 3" x 3"x 0.060" Scalloped 2 - 2" x 3" x 0.050" 3#8 r x 5" x 0.050" X 0.100 3" x 3"x 0.060" Scalloped 2 - 2" x 3" x 0.050" 3#8 r x 6" x 0.050- X 0.120 3" x 3"x 0.060" Scalloped 2 - 2" x 3" x 0.050" 3 #10 2- x 7- x 0.055- x 0.120- 3' x 3" x 0.093" 3 2 2" x 4" x 0.050" 3 #10 2" x 8" x o.on- x 0.224" 3" x 3" x 0.093" 3 2 2" x 4" x 0.050" 3 #12 2" x 9" x o.on" x 0.224- 3" x 3" x 0.12S" 4 3 2" x 4" x 0.050" 3 #14 r x 9" x 0.082- x 0.306- 3" x 3" x 0.12S" 4 3 2" x 4" x 0.050" 3 #14 2- x 10- x 0.092- x 0.369" 4"x4"xO.125" 6 4 2" x 4" x 0.050" 4)#14 The minimum number of thru bolts Is (2) " Minimum post/beam may be used .. minimum kn.. brace Table 2.4.1 Footings. Maximum Roof Area for Attached Carport Posts Wind Zone. 100 MPH 110 MPH 120 MPH 123 MPH 130 MPH 140 MPH 150 MPH Attached Cover Ualift . " 20 tUSF 24 tUSF 29 tUSF 30.5 tUSF 34 tUSF 39 tUSF 45 tUSF Free-5tandlna Cover Uallft . 10 tUSF 11 tUSF 13 tUSF 13.3 tUSF 17 tIISF 20 tUSF 23 tIISF ExlstJng Slab an Grade wtth unknown 20 18 15 14 13 11 10 reinforcement Isolated Footing Uplift Maximum Attributable Roof Area In Square Feet Dimensions- Rating (Ibs.) 1'.()" x 1'.()- x 1'.()" , 520 26 21 18 17 15 13 11 1'-4" x 1'-4- x 1'-4" 1000 50 41 34 33 29 26 22 1'.(j" x 1'.(j" x 1'.(j- 1320 66 55 45 43 39 34 29 1'-8" x 1'-8" x 2'.()" 2040 102 85 70 67 60 52 45 1'-8" x 1'-8" x 2'.(j" 2540 127 106 88 84 75 65 57 2'.()" x 2'.()" x 2'.()" 2640 132 110 91 87 78 68 59 2'.()" x 2'.()" x 2'.(j- 3300 165 138 114 108 97 85 73 2'.(j" x 2'.(j" x 2'.(j- 4000 230 191 158 151 135 118 102 2'.(j" x 2'.(j" x 3'.()" 4800 276 230 190 181 162 141 123 Notes : 1. Isolated Footing is a poured concrete rectangular solid (length x Width x Depth). 2. Slab on grade must be new or in good condition. 3. For free-standing covers multiply the above roof areas by 2.0. Pre-Cast Block Footing Pre-east footing block ( 16" x 16" x 4") at 24" below grade with 80 , baa pre-mlx concrete and backfilled to grade. Maximum Attributable Roof Area In Square Feet 100 MPH 110 MPH 120 MPH 123 MPH 130 MPH 140 MPH 150 MPH Dimensions Uplift Rating flbs.l 20 tIISF 24 tIISF 29 tIISF 30.5 t#lSF 34 t#lSF 39 tUSF 45 tUSF 1 x 80# Baa 1,734 87 72 60 57 51 44 38 2 x 80# Bag 1,819 91 76 63 59 54 46 40 3 x 80# Bag 1,904 95 79 66 62 56 49 42 Note: Maximum uplift on post is detennined by multipying maxlmum attributable roof area x applied load. Example: Post tributary roof area = 77', Applied load for 110 MPH wind zone = 24#1Sq. Fl, Uplift on post = 77 x 24 = 1,540# " Roof areas are based on attached cover uplift loads. Lawrence E. Bennett, P. E. CML ENGINEER - DEVELOPMENT CONSUL TANT P.O. BOX 4368. SOUTH DAYTONA. FL 32121 TELEPHONE (386) 757-4774 FAX (386) 767-6556 SEAL PAGE @ COPYRIGHT 2002 2-41 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOVT THE WRfTTEN PERMISSION OF LAWRENCE E BENNETT, P.E.