HomeMy WebLinkAbout03-2130
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
2130
Permit Number: 2130
Permit Type: COMMERCIAL
Class of Work: COMMERCIAL HOOD
Proposed Use: COMMERCIAL
Square Feet:
Est. Value:
Improv. Cost~ 2,180.00
Date Issued: 6/03/2003
Total Fees: 45.00
Amount Paid: 45.00
Date Paid: 6/03/2003
Work Desc: installin
Address: 5740 7TH ST
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number:
Name: VASQUEZ,MANUEL
Address: 5740 7TH ST
ZEPHYRHILLS, FL. 33542
Phone:
FOOTER ROUGH ELECTRIC DUCTS INSTALLED
PRE-SLAB CONSTRUCTION POLE i DUCTS INSULATED
LINTEL PRE-METER I. FINAL MECHANICAL
FRAME MISC MISC
INSULATION WALL MISC MISC.
INSULATION CEILING MISC. MISC.
DRIVEWAY MISC. , MISC. FIRE DEPT. FINAL
REINSPEC1l0N FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice fOr~
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
... . Complete Plans, Specifications and Fee Must Accompany Application.
_____ ..____ All workshall be p~.!1ormed in accordance with City Codes and Ordinances
NO OCCUPANCY BEFORE C.O.
- ~ ~LL:AQQ . ~
-)<c2RACTciR~ATURE - - PERMIT OFFI
~~ FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
~OLL~,
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8~ Street, Zephyrhills, FL 33542
813-780-0020 FAX:813-780-0021
DATE RECEIVED ;;-- ,;LI-o_~
PLANS REVIEW FliJi:
OWNER'S NAME M':-H.E'I cH,lC1;t-n...e V.?>'9.H,"'~
PHONE
c::...----.
JOB ADDRESS )7'" () "7 Sf.
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL ID #
(OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPSED: ONEW CONSTRUCTION
o ADDITION
OALTERATION
o REPAIR
~NSTALL
o SIGN
o MOVE
o DEMOLISH
PROPOSED USE: OSGL FAMILY DWELLING
~OMMERCIAL
OMULTI-FAMILY
o INDUSTRIAL
0# OF UNITS
o SWIMMING POOL
o MOBILE HOME
o OTHER
c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL
DESCRI PTION OF WORK r IIrb II 8 \ rz"9' e It &01:1
BUILDING SIZE
SQUARE FOOTAGE
HEIGHT
RESIDENTIAL:
COMMERCIAL:
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ~-+-_
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. ~ ~ LV
PERMITS REQUESTE~~j ~~
VALUATION OF TOTAL CONSTRUCT~
$
o ELECTRICAL
AMP SERVICE
o
FLORIDA POWER
~~
.rr
o W.R;1;t/1&~~
INSTALLATION/1 0 tJ
'/ b
I
{
i
o BUILDING
o PLUMBING
~MECHANICAL
$
;U80~
.
VALUATION OF MECHANCIAL
o GAS
o ROOFING
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAO YES
o NO
BUILDER
SIGNATURE
COMPANY
STATE CERT OR ~EGIST #
CITY PROCESSING #
/
**********************************************7*******************
./
COMPANY /
STATE CERT pR REGIST #
CITY PROCESSING #
/
ELECTRICIAN
SIGNATURE
******************************************* **********************
COMPANY
STATE C
CITY P
#
PLUMBER
SIGNATURE
SIGNATURE
******************************************************************
~ . COMPANY c .+,.... t'''''<l<(-+Y r). c><.''f ~t'-I~{, I '1'" "
^- STATE CERT OR REGIST # CSCOo""'''ir
~ CITY PROCESSING #
'----rJ ~ ~ '5 to ~ 0 /-::-;-
************************************~*{***************2/7***~
~
MECHANICAL
OTHER
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
*****************************************************************
CONDITIONS OF PERMIT AFFIDAVIT
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" ~hich
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPON~IBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-788-6611.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VA DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
STATE OF FLORIP;::7~ ~
COUNTY OF \~ t2 .1
The foregoing instrument was
Before me this f, ay of
by
SIGNATURE:
CONTRACTOR
acknowledged
,20125
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was acknowle~ed
Before me this _day of ,_
by
(n e of person acknowledged) (name of person acknowledged)
Dwho is personally known to me, or C1ho is personally known to me, or
~~s produced;:=L 'l). L .8t,~O-7f'.?-1f- Dwho has produced ....
'[]~d~type of identificatio~~-U (type of 1dent1f1cat1on)
a~~o~~12~ and who Ddid [}iid not take an oath
Signature of person taking acknowledgement Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped
A Commercial Range Hood System
FOR
Manuel and Corrine Vasquez
5740 7th Street
Zephyrhills, FI 33576
/0 ')
: Ji .L "- u -CJ3
' /' ,:;1
d
5hi!
r 1;r
Hood to be 18 gauge galvanized or stainless steel, 24" H, and overhang
cooking equipment 6" on all open sides.
All joints to be continuous, liquid tight external weld.
Grease filters to be UL Listed and sized to facilitate airflow at a rate
consistent with listing requirements.
Filters shall be framed, and frame sealed to canopy in such manner as to
prevent grease from passing between collection area and plenum area.
Hood to be supported by material equal to that used for hood construction.
Exbaust duct to be 16 gauge galvanized steel with all joints either lapped or
butted and welded with continuous, liquid tight external weld. Hood-to-duct
joint may be welded internally with no grease traps formed.
Clearance. Hood and exhaust duct to be min. ] 8" clear of combustibles or
protect per NFPA-96 or Florida Mechanical Code.
Exhaust roof mounting curb to be 16 gauge, welded, sealed to exhaust duct,
and hinged to blower allowing access for cleaning and burglars.
Airflow:
( exhaust to be min. ] 00 CFM PSF hood opening on hoods with 2 or three
Sides open, as required for others.)
. Hood opening :2 I . &0/ /0{
· Total exhaust required :2 I q...,
· Duct size I -:3 " X / ~ "
· Duct velocity '7 D:l. FPM @ .. 3
· Exhaust blower:
Model Cock /6 ~-v > 8
RPM q2,.)"
Elect. Req. I J S- V I d7
· Make-up air approximately equal to exhaust and provided by:
Model :led., SC.q~7 P:....,th;, L'~e..fd..J'
Elect. Req. I' S- V I q,
Discharge through ce ; Ij ,., f cJ. " f.f1.4 sey
Airflow test and adjustments to be accomplished upon start-up.
Sq.Ft.
CFM
" SP
UL Listed for grease removal
~:!J
,(')
i=
r.~
is ". 13 Q1
..... NI ?'3
a.€ -3
i r ~ f
f'I m
" C/)
0'2. ~
. f'I" 2
o 0
9 ...
ere.
1::" -~
l!l ~ "'Cll
~, ?'
g: _ ~ 'r.v.s)o.
.. f'I "...
a " .....~
.. :;a ~ ~
;Q. SHili I
~~. ~ln f~ I it
D 2'1-:;: i~
1 ~Jl i.
Po l~
~ ~ ~~.:
~:b ~ ~ .':~ .::.
'-~ (~ ~:r:
'l.... ........ -
~ sS';:';
. ~ ~~
, ~ E
~ ~, -"
" ~
~ ~ ~
~ ~
~
~
......
'"
"'"
~
,
~
..
.
i
0.-
~
~
of
1li
",-=
ag-=[)l
~ S"
:-Sl':-3J>> ~
...~3 ill
(I ~.i3 ~
t rl
~
I
~
(I
~
~
...
... -.aof'-- ...,
. I .... -+-~,
':t
"
~
-
J:
~
~
-
Ii:
SF
, -! - .,
, .
. I
.~ -'
-
r
,...
I
,
E ",el V;t"""
,
10 r
r
;1.0.1"
E.FI
7~'
"'DoJ fr_e
J.r,#w~11
pr," r&t ft!r JJF,,4..(t
s e6 ,(',~s,<!,.:,f
~
16
Ii ~.f~1 u..,/1 S4i81e1
hoppl-1' - f/pCJ"
A Commercial Range Hood System
FOR
Manuel and Corrine Vasquez
5740 7th Street
Zephyrhills, FI 33576
O.#J Ilj .J~
J) ~- )I
5/1,1J
p.l D
-t..r.
Hood to be 18 gauge galvanized or stainless steel, 24" H, and overhang
cooking equipment 6" on all open sides.
All joints to be continuous, liquid tight external weld.
Grease filters to be UL Listed and sized to facilitate airflow at a rate
consistent with listing requirements.
Filters shaH be framed, and frame sealed to canopy in such manner as to
prevent grease from passing between collection area and plenum area.
Hood to be supported by material equal to that used for hood construction.
Exbaust duct to be 16 gauge galvanized steel with all joints either lapped or
butted and welded with continuous, liquid tight external weld. Hood-to-duct
joint may be welded internally with no grease traps formed.
Clearance. Hood and exhaust duct to be min. ] 8" clear of combustibles or
protect per NFPA-96 or Florida Mechanical Code.
Exhaust roof mounting curb to be 16 gauge, welded, sealed to exhaust duct,
and hinged to blower allowing access for cleaning and burglars.
Airflow:
( exhaust to be min. 100 CFM PSF hood opening on hoods with 2 or three
Sides open, as required for others.)
· Hood opening :2 I . 011-{
· Total exhaust required :2 J '" '"
· Duct size f J " X I l-#
· Duct velocity '7 Dol FPM @ .. 3
· Exhaust blower:
Model Cock 16 j-Y ~ 8
RPM '12)'
Elect. Req. tiS- V I tP
· Make-up air approximately equal to exhaust and provided by:
Model le;2. SC'167 t>;>''fth;.L,..e.f'~''f
Elect. Req. J' ') V I cP
Discharge through ce ; (p, 9 d.. f.f1.4 sev-
Airflow test and adjustments to be accomplished upon start-up.
Sq.Ft.
CFM
"
" SP
UL Listed for grease removal
~~
'n
ft=
'E~
p .,. -wCi1
-,.. :SO 3
e.€ ....3
/I
~l:' 51
a a m
." (J)
Oji' ~
. '" ~
o 0
e ...
ere.
j:: /I -Oo,j
~ ~ 10>111
_' ;S'
~ _~ y:s)o.
! R ~ <9~~
~ Ii S ~.J)l a I r
~~. ~~n i~ I *t
D at::: 311
i " i1i~
/I ~J- i. - -
Po t~ i~ i
.....
..,
~ -a+r--- toI
. I .&, -+-~
~
"
~
-
~
~ f\JtJ
~ ~
ft ~
Ii:
A:
to'
~~~
~,
~~\1~
~~ ~~~2:?
~ t\' :<
.. :::c'
~~.....-
K ~e.~
~~ '=' ::::
~} ;v
, ,."
?o.. ~~?
\ ~,R
" .;-+
~
\ ~
~
..
:-
.;
.
~
...
0.-
..
~
.l
~
SF
,./-~
, :
. I
"- ..
r .,
---10 1-
,...
I '
,
E ~c1 V;~,."
-~
J.11"
E.FI
78"
v,Jtltl; Fr_e
J. ~ '1 "'.III
pr,+ rd /f!r JJF,,4-ft
s f!6 , i'," sl, "'~(-
-~
16
Ii ~"'.&I w.:-/l sl,.it)lp
I "',,~ "f~ - (/"0;-