HomeMy WebLinkAbout03-2242
1-
, .
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
2242
Permit Number: 2242 Issued: 7/23/2003
Permit Type: GENERAL BUILDING PERMIT
Class of Work: SHED INSTALLATION
Proposed Use: NOT APPLICABLE
Sq. Feet: Est. Value:
Cost: 2,067.00 Total Fees: 67.501
Amount Paid: 67:50 Date Paid: 7/22/20031
Address: 5115 10TH ST
ZEPHYRHILLS, FL.
Township: Range:
Lot(s): Block: Section:
Book: Page:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number:
Name:
Addr:
Name: CASE TOM
Address: 5115 10TH ST
ZEPHYRHILLS, FL. 33542
Lie:
10 X 16 STORAGE SHED
Phone:
- J \~~
Yl V\ 1l?--"l\~
. 1 R UGH
PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED
LINTEL PRE-METER WATER FINAL MECHANICAL
FRAME , MISC SEWER ! MISC
INSULATION WALL ; MISC MISC. i MISC.
INSULATION CEILING : MISC. · MISC. i MISC.
DRIVEWAY I MISC. i MISC. i FIRE DEPT. FINAL
I L I
REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
I improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
befo~recording your notice of commencement."
NO OCCUPANCY BEFORE C.O.
4~-~- .~~
C ~RACTORS SIGNATURE .____u PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8th Street, Zephyrhills, FL 33542
813-780-0020 FAX:813-780-0021
/"1 - /Cl -2)~
DATE RECE IVED L ----6L
PLANS REVIEW FEE .
JOB ADDRESS
PH~ii~1~~
\LLS FL. 3354;;L-
OWNER'S NAME
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL ID #
J I ;;;J..(P;2...\ 00 [{) C).() bit:? (){)fJ 0 (OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPSED: ONEW CONSTRUCTION
o ADDITION
o ALTERAT ION
o REPAIR
o INSTALL
OSIGN
o MOVE
o DEMOLISH
o COMMERCIAL
o MOBILE HOME
YOTHER E
5'"10 K c:<.. G-
O RESTAURANT & HEALTH DEPARTMENT APPROVAL ,( fj
~Ns-f-o.~e Dr; li<Pa-dy Q:Jo..de ~\~e~~
/ () X/Co SQUARE FOOTAGE / (,0 HEIGHT ~ 6 q
::;I;to
& (1) SET ENERGY FORMS.
FORMS.
OMULTI-FAMILY
0# OF UNITS
PROPOSED USE: OSGL FAMILY DWELLING
o INDUSTRIAL
o SWIMMING POOL
DESCRIPTION OF WORK
BUILDING SIZE
RESIDENTIAL:
COMMERCIAL:
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
~ BUILDING
o ELECTRICAL
PERMITS REQUESTED
?J U G, 7 . 0 0 VALUATION OF TOTAL CONSTRUCTION
$
AMP SERVICE
o FLORIDA POWER
o W.R.E.C.
o PLUMBING
o MECHANICAL
$
VALUATION OF MECHANCIAL INSTALLATION
o GAS
o ROOFING
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
IS PROJECT IN FLOOD ZONE AREAO YES fi( NO
FINISHED FLOOR ELEVATIONS
l/)~
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
~
BUILDER
******************************************************************
ELECTRICIAN
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
**************************t***************************************
PLUMBER
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
******************************************************************
MECHANICAL
SIGNATURE
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
*****************************************************************
OTHER
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
*****************************************************************
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be. more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable.deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor SectionsU of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "ownerU prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A,etc.u, it is
understood that a drainage plan addressing a "compensating volumeu will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correc'tion of errors in plans, .construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _ day of
by
acknowledged
20_
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _day of
by
acknowledged
,20_
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
[1ho is personally known to me, or
Dwho has produced
(type
and whoD did 0 did not
of identification)
take an oath.
Dwho has produced
(type of identification)
and who Ddid DHd not take an oath
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped
r'
\.........l
MANUFACTURERS OF THE:
.U~BED
Date
~'
~
'"
Customer ORDER
......,~'
SOLD TO:
....".-'
:" .- .- ~-.
"~ ...;.:.-
-"':' ../,,~' "
, -
Office
-'-..-
Phone:
Other
Shipped To'
=
-.--
-;.:;.;. ...
-::;;:;)'
Phone:'
.~ - :" '; ~," ~~
Office:
Location
Sold By:
Phone:
-,;",y,.-1,...!.,!.,...
..... - -,--
.- ....
Delivery Date
Contact Person:
Terms:
<
-....'
:::r r.l
.--; ...
;J'-
Qty.
Size
Model
Base Color
Trim Color
Roof
:. ...........'
Unit Price
Amount
--..--.: ~ ~
Corners
I' -,-'
.'
Door Size " Style ,.
Door Size Style
Window(s) Size ~ ~
'7 --! " ...-'
Window(s) Size
Vent(s) Electric
Loading Instructions: ...,.J :I:;;
-,:;
~,... ~.
_..,,,,,,,,,,;:. J
,./ -
Hinge
Hinge
~,
~~, ::: .--#1
,. .'v',-'
-~ ,<
- .'
_. ~
-
Comments:
-
,
~
Sale Amount
Misc. Charges
Frei ht
Sales Tax
Total
Amt. Received
Balance Due
7".
.,..-,
,. - -' .,.
/
::..---;
." ..;' ~. .~. ';'''--;:-
-?-
~i) :::.,. .-:::"' .. '..:;:.,
Customer Signature .." .--"' , ''-
Terms & Conditions:
1 ) Price of building includes delivery.
2) Customer is responsible for any necessary permits for
installation of building.
3) Smithbilt Industries is not responsible for removal of
fences, trees, existing sheds, etc.
4) Smithbilt Industries is not responsible for damage to
underground utilities.
5) All electrical connections should be made by a licensed
electrician and completed per existing National Electrical
Code and local Code Requirements.
/;~,:",;f
~-----
9
il ~
Avt
~ ~.(-
2 ~_
~
~ If
lV1
#
(
!'Iv
a
()
\)
~
~
r-
r-
n,
-<
--
\<.:... r:.:!.
~ ....
-
.'''''- ~~
.,-..
-...
a
0') ......
a :::r-
Oo
~ U)
::tll
~ [11'
rr,
""""-I
L \ - ~~ ;., I .~~;,C \ ":;. .~ ~ ~;,ol. :; <~:
Leg.al Description
Lots 5, 6, and the North 1'/2 of Lot 7, Block 205, CITY
OF ZEPHYRHILLS, according to the Plat thereof as
recorded in Plat Book ..1, Page 54, of the Public
Records of Pasco County, Florida.
"~ ,:l - ~ "~
Commullity Number: 120235 Pallel: 0005
SuffIX: C F.LR.M. Date: 12/17/91 Flood Zone: X
Field Work: 1/4/01 Completed: 1/9/01
Certified To:
Thomas W Case; Selma Ann Case; Suns tate Title
Insurance Agency; First American Title Insurance
Company; CTX Mor~gage Company, its successors
and/or assigns.
20..0.'
SHALLCOMPL yW111lALL
1. WORK '"'ES FLORlDAs\AJPE)G "205"
REvAlUNGCOv, C~
ODE. NATIONAL aECflU ....,.. ~CES3
, l{YRHILLSORDu"lJ"\1'
30.0.'
BLK "205"
4
FD.
3/4" IP
140.0.0.' P. 139.98' M.
FD.
3/4" IP
90'56'02" M.
'"
...
<;;
'"
'"
...
'"
q
BLK "205"
5
s:::
CO V.
47.3'
20.87'
'-J
ry,
Cl
Cl
l:::J
'-J
(J)
Cl
c.. Cl
~1l a
'~ :<:: \:)
...
'"
q ~
Cl
'-J
'-J ~ BLK "205"
6 0, 6
~ ~ / b' 7) ~ . I ~ / ~4'1
~ 89 US '5" tlLK lt1j05- POR- ON OF
/0.0' BLK "205" 0.3 140.0.0.' P 140..53' M.
2, 7 REMAINDER OF
20.0'
...
~
"
'"
'" -
. '"
" 6
....90.29.12" M. C.
o. '
89'30'47" M.
.0' Ft:!.
PK
NAIL
~ c;
g ~
'Cl
C)
lJ
FD.
5/8" fR.
BLK "205 n
8
C)
en
Cl
Cl
FD. d"x4" s:::
SECOR OF LOT 10~'NJ3LK "205 30.0'
200.'
SMITHBIL T INDUSTRIES, INC.
PORTABLE BUILDING ANCHORS
BUILDING ANCHOR SCHEDULE
NO. OF ANCH. @ NO. OF ANCH. @ TOTAL ANCH.
BUILDING SIZE EA. END OF BLDG. EA. SIDE OF BLDG PER BLDG.
8',10',12'&14' WIDE TO 24' LONG 2 4
48' 2 1 6
50' 2 2 8
20',22'&24' WIDE TO 24' LONG 4 8
48' 4 10
50' 4 2 12
BUILDING ANCHOR DATA
MODEL BAR EYE HELIX
NUMBER LENGTH DIAMETER DIAMETER DIAMETER
36SHE34 30" 1/2" 1 1 /2" 4"
UPLIFT CAPACITY
IN NORMAL SOIL
2500 Ibs.
PLAt ~S REVIEWED
DATE '7, ~~ - D5
BUll OING DEPT APPROVED
BOL T THRU ANL:H. & 2x6
SKID OR HEADER BEAM
w/ 3/8"0 x 4" LAG BOLT
jSKID (TYP.) w/ 3/32"x2"0 WASHER
g~ty WIDE .[ -1- - - - rSIDE - AN~H_ -- - - -l. BAR
~:i-u_u_u_----_. -I:
NOTE:
THESE ANCHORS MEET THE WIND REQUIREMENTS OF
THE FLORIDA 2001 BUILDING CODE AND THE AMERICAN
SOCIETY OF CIVIL ENGINEERS STANDARD CODE ASCE 7-98.
WIND LOAD: 150 M.P.H.
o
..
~.L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~.
. .
ANCH.
ANCHOR SPACING PLAN
HELIX ---
END
SCALE NONE
DRAWN BY 1M
CHECKED BY W.J.M.
CHECKED BY
DATE
1 B OJ
1 B OJ
LOCA nON or JOB
ANYWHERE. FL
M
PRO~CT NO.
020JO
McCARTHY ENGINEERING. INC.
STRUCTURAL CONSUL TA.NTS LAK[lANO, fLORID"
2225 EAST [{)C{WOOO 0Rl~ SUIT[ 4 - LAKElANO, n. JJeOJ
""Of<[ (eliJ) 667-1769' fAX (ell)) 651-1790
C(RMCATE CJ" AUTHORlZA'J'IC:W No. 6J94
WlJliom J lrkCorltly P.E_ 24S5J
TYPICAL PORT ABLE BUILDING ANCHORS
SMITHBIL T INDUSTRIES. INC.
1061 U.S. HWY. 92 WEST
AUBURNDALE FLORIDA
WG. NO .0.-1