HomeMy WebLinkAbout03-2486
,--
CITY OF ZEPHYRHlllS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
2486
Permit Number:
Permit Type:
Class of Work:
Proposed Use:
Square Feet:
Est. Value:
Improv. Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
2486
ADDITION/ALTERATION
434-ADD/AL T RESIDENTIAL
NOT APPLICABLE
7,000,00
11/06/2003
257,70
257.70
11/05/2003
FAMILY ROOM AND PATIO
Address: 37651 NEWPORT DR
ZEPHYRHILLS, FL.
Township: Range: Book:
I lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
I Name: ROBERT MCILROY
Address: 37651 NEWPORT DR
ZEPHYRHILLS, FL. 33542
Phone:
35:00 I RADON
I
4.20
L ~ ,jl GJ-//r/IJY
V--I (\- ~o
iff 0tt
I A LED
D I CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED
PRE-METER WATER FINAL MECHANICAL
J1J~ MISC SEWER MISC
I MISC MISC. I MISC.
MISC. MISC. i MISC.
DRIVEW~Y . .. MISC. _ MISC. _ ~RE DE_PT. FINAL .
REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
Ihe paYI!l_~':1t of inspection fees s~~lLbe mad~~ before any ~rther permits will be iS~l:led to the .Q€rson owning same _
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for-
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
____u~__________~~ Complete Plans, Specifications and Fee Must Accompany Application, -~-----------
.. ___,1\11 Vlfork sh~U_ be perform_~ in accordance with City Codes a_nd Ordina~~es
NO OCCUPANCY BEFORE C.O.
"---- ---- ----~-----.,-----_....
~._~~ ~
-CONTRACTOR ~~t~~': 1~;ECTlON _ 8 HOUR NOn~E REQ~~E~T OFFI
PROTECT CARD FROM WEATHER.
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8th Street, Zephyrhills, FL 33542
813-780-0020 FAX:813-780-0021 ~~. lo~
DATE RECE IVED lJ.---=-. --:::..
PLANS REVIEW FEE
OWNER'S NAME ROBERT f()C\l-ROy C~L\L\AN) PHONE 8\3-~~O.~\(J88
JOB ADDRESS 37 coSt NEk.)Fn~ '2:>R, Z.E.-PHYRH )LLS ~L 33 <04-2..
LEGAL DESCRIPTION: LOT(S) 0780 BLOCK SUBDIVISION 0 \3.6
PARCEL ID # 03- 2 Co, - 2\- O\:So- oOClOO-Oi80 (OBTAIN FROM PROPERTY TAX NOTICEl
WORK PROPSED: oNEW CONSTRUCTION ~DDITION oALTERATION o REPAIR o INSTALL
o SIGN o MOVE 0 DEMOLISH
PROPOSED USE: ~GL FAMILY DWELLING oMULTI-FAMILY 0# OF UNITS ~OBILE HOME
o COMMERC IAL o INDUSTRIAL o SWIMMING POOL o OTHER
c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL
DESCRIPTION OF WORK p..;;pD "F~""') L ~ 'R60<"\ ~ ?AI\ 0
BUILDING SIZE \ 4-1 ~ 20 I SQUARE FOOTAGE 2~o
HEIGHT CbFT.
RESIDENTIAL:
COMMERCIAL:
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS,
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION,
PERMITS REQUESTED
lit'~UILDING
~LECTRICAL
o PLUfvJB I NG
-V' fvIEC HAN I CAL
$ 7) 000
VALUATION OF TOTAL CONSTRUCTION
l~ AMP SERVICE
p-,)(\STtN~
o FLORIDA POWER
0' W,R,E,C.
$
30a
VALUATION OF MECHANCIAL INSTALLATION
o GAS
o ROOFING
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAo YES
[E( NO
COMPANY O/fTJ! d'1.
STATE CERT OR REGIST #
CITY PROCESSING #
BUILDER ~
-~ ~~YJ.
SIGNATURE i . -~----- . ) .
1<o&..'el (X) C, l....:iGc"--l
********************************************************~k******~**
SIGNATURE V
,,?,--_/i
'-
, -c::,~
COMPANY (/U Lo?1..v5 -'
STATE CERT O~REGIST #
CITY PROCESSING #
ELECTRICIAN
******************************************************************
PLUMBER
COMPANY
STATE CERT OR RE~JSl'-"'lr
CITY PROCES,.SI#G'-#
'-----~---..--.~.- ..--."--"-..,
/ ,
********************************************f***#*). ***************
MECHANICAL COMPANY \ L-'J J-""j/1..v1
(.~. ., ._:----/-. STATE CERT 'OR REGIST #
SIGNATURE L,/ ....- - . . L- CITY PROCESSING #
* * * * * * * * * * * * * * * * * * * * * * * * * * * * 1 * * * * * * * * * * * * *f-.".*-*.* * * * * * * * * * * * * * * * * k *
JIll
.
SIGNATURE
OTHER " ~ RoOF
~-,-=~<~. ~-\~ r-
SIGNATURE .....~). -.-~~I
\
COMPANY( ~/ ~. L/J ./
STATE CER"- OR REGIST r--
CITY PROCESSING #
*****************************************************************
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions,
B, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law, If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work, If the contractor wislles
you to sign as contractor that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhi1Is.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D, CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guideu prepared by the Florida Department of Agriculture
and Consumer Affairs, If the ~ppIicant is someone other that the "ownerU, I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "Owneru prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development,
Application is hereby made to obtain a permit to do work and installation as indicated, I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance, Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U,S, Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "AU or "A,etc,U, it is
understood that a drainage plan addressing a "compensating volumeu will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance,
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code, Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced, One 90 day extension of time
may be allowed for the permit with fee charge of $15,00, The extension shall be requested
in wrj.ting to the Building Official, An approved inspection must be logged during each six
month period, or the project will be considered abandoned,
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT ~]AY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENTu,
~~'~
SIGNATURE: OWNER OR AGENT
SIGNATURE:
CONTRACTOR
~> \
STATE OF FLORIDA ~ 50
COUNTY OF
The foregoing ~ume. nt was ackn<;>wledged"2
Be fort=< me ttjis V dy of A.)()I}ewber, 2QQ..:?
by oher i C' 1/..12.0
(name of person acknowledged)
Dwho is personally known to me, or
~ho
STATE OF FLORIDA rJ2
COUNTY OF YCZ $CO
The foregoing ins ument wa7 ackkledged ,
Before this day of/1 {1W''''--_'r::., 20 D3
by l' ( L-ro
(name of person acknowledged)
Qho is personally known to me, or
~~o has produced 'P L <
(type of identification)
[}:iid not take an oath
Name typed,
,\"1/,, Suzanne Bahr
-,;"tY'-.YPIJe.", . . #991~+1~1
~~, ". ,\;~ CUlllIt\l551011
~:~'~~E~,Iir&~?2006
-'5,' "1)..;<_ fll Th
-:-.....~J.;.Oi:f~O~...:: ~onded. ru
11/111\\\\ Atlantlc Bondmg Co., Ine
Signature of lerson taking acknowledgment
,\,"1/1, Suzanne Bahr
.......'~~y.PJ.l&'<, . J.
~..?~~~'_ COIIIIIIISSIOII #DD157131
Name typ~, 'lf~~'itef.'~ov'~,nml~6'
-,..~". '0"'-'- Bonded Thru
J"'II~~t\~\\' Atlantic Bonding Co., Inc.
Robert Mcilroy
37651 Newport Dr.
SQ. FEET
MAIN OR LIVING: 280
OTHER AREA UNDER ROOF: 140
OTHER: -
V ALUA TION #REF!
FEE SHEET $ 120,00
ADDRESS $ -
DRIVEWAY $ -
BUILDING: $ 180.00
CREDIT: $ -
BUILDING LESS CREDIT: $ 180.00
ELECTRICAL: $ 38.50
PLUMBING:
MECHANICAL: $ 35,00
RADON: $ 4,20
TOTAL $ 257.70
SEWER: $ -
WATER: $ -
IRRIGATION: $ -
TOTAL: $ -
WATER METERI $
IRRIGATION METER $
~ I
SUB-TOTAL $
257.70 I
SIF'S:I $
97.5% $
2.5% $
- I
- I
T IF'S :1 $
99% $
1% $
TOTAL: $
257.70 I
NEED
NOTICE OF COMMENCEMENT
&.
OWNERS AFFIDAVIT
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600C-97 Residential Limited Applications Prescriptive Method C CENTRAL 4 5 6
Small Additions, Renovations & Building Systems Department of Community Affairs
Compliance with Method C of Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the use of Form 6OOC-97 for additions of 600 square feet or less, site. installed components
of manufactured homes, and renovations to single and multifamily residences. Altemative methods are provided for additions by use of Form 6ooB.97 or 600A-97.
PROJECT NAME: BUILDER: ~OBEer'{Y)C\\.....R.O'Y OWNbe
AND ADDRESS: PERMITTING CLIMATE D D
4-"2 OFFICE: ZONE: 4 D 5 6
OWNER: PERMITNO.~ JURISDICTION NO.: ITIITTI
SMALL ADDITIONS TO EXISTING RESIDENCES (600 Square feet or less of conditioned area). Prescriptive requirements in Tables 6C-1, 6C-2 and 6C-3 apply only to the
components of the addition, not to the existing building. Space heating, cooling, and water heating equipment efficiency levels must be met only when equipment is installed
specifically to serve the addition or is being installed in conjunction with the addition construction. Components separating unconditioned spaces from conditioned spaces must
meet the prescribed minimum insulation levels. RENOVATIONS (Residential buildings undergoing renovations costing more than 30% of the assessed value of the building).
Prescriptive requirements in Tables 6C-1 and 6C-2 apply only to the components and equipment being renovated or replaced. MANUFACTURED HOMES AND BUILDINGS. Only site-
installed components and features are covered by this form. BUILDING SYSTEMS Comply when complete new system is installed. Please Print C K
1. Renovation, Addition, New System or Manufactured Home
2, Single family detached or Multifamily attached
3, If Multifamily-No. of units covered by this submission
4. Conditioned floor area (sq. ft.)
5. Predominant eave overhang (ft.)
6. Glass area and type:
a, Clear glass
b. Tint, film or solar screen
7. Percentage of glass to floor area
8. Floor type and insulation:
a. Slab-on-grade (R-value)
b, Wood, raised (R-value)
c. Wood, common (R-value)
d, Concrete, raised (R-value)
e. Concrete, common (R-value)
9. Wall type and insulation:
a. Exterior:
1. Masonry (Insulation R-value)
2, Wood frame (Insulation R-value)
b, Adjacent:
1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
c. Marriage Walls of Multiple Units* (Yes/No)
10, Ceiling type and insulation:
a. Under attic (Insulation R-value)
b, Single assembly (Insulation R-value)
11. Cooling system*
(Types: central, room unit, package terminal A.C., gas, existing, none)
12. Heating system*: (Types: heat pump, elec. strip, natural gas, L.P. gas,
gas h_p., room or PTAC, existing, none)
13. Air Distribution System*:
a. Backflow damper or single package systems* (Yes/No)
b. Ducts on marriage walls adequately sealed* (Yes/No)
14. Hot water system:
(Types: elec., natural gas, other, existing, none)
* Pertains to manufactured homes with site installed components.
1,
2,
3.
4.
5.
ADC\'1'\ON
S\NGl-f
Double Pane
sq, ft.
sq. ft.
lin. ft.
sq, ft.
sq. ft.
sq. ft.
sq. ft.
sq. ft.
4&0 sq. ft.
sq, ft.
140 sq, ft.
sq. ft.
-000 sq. ft.
Type: p~e:
SEERlEER: \ 0
Type: t.L.E:.c..-. STRIP
HSPF/COP/AFUE:
Type: \ \...:t::..e.Te\t"
EF:
2. ~O c::.~
l -'1'
6a.
6b.
7,
Single Pane
~G sq, ft.
sq. ft.
,I), %
8a.
8b,
8c,
8d,
8e,
R= ~
R=
R=
R=
R=
Review of plans and specifications covered by this calculation indicates compliance
With the Florida Energy Code. Before construction is completed, this building will be
inspected for compliance in accordance with Section 553.908, F_S.
BUilDING OFFICIAL:
DATE:
9a-1 R=
9a-2 R= \<;2)
9b-1 R=
9b-2 R= l~
9c
10a. R=
10b. R= "'30
11.
12.
13a.
13b.
14.
'/E..S
Revised 1998
Climate Zones 4 5 6
TABLE 6C.l : PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDmONS (600 Sq, A. and less), RENOVATIONS TO EXISTING BUILDINGS AND SITE-INSTALLED COMPONENTS OF MANUFACTURED HOMES.
MINIMUM INSTALLED
EQUIPMENT EFFICIENCY EFFICIENCY
Central AlC - Split SEER = 10.0 SEER = -
C)
z -Single Pkg. SEER = 9.7 SEER =
::::; -
0 Room unit or PT AC EER 8.5* EER
0 = = -
u
Electric Resistance ANY
C) Heat pump - Split HSPF = 6.8 HSPF = -
z - Single Pkg. HSPF 6_6 HSPF
~ = = -
I Room unit or PTH P COP = 2.7* HSPFI = -
w COP
~
"- Gas, natural or propane AFUE = .78 AFUE =
en -
Fuel Oil AFUE = .78 AFUE = -
a: Electric Resistance EF = _88 EF = -~
I- W
o!;;: Gas; Natural or L.P. EF = .54 EF =
I;s: -
Fuel Oil EF = .54 EF =
* See Table 6-3,6-7
MINIMUM INSULATION
COMPONENT INSULATION INSTALLED
Concrete Block R-5
en Frame, 2' x 4' R-ll R-tl
...J Frame, 2' x 6' R-19
...J
<( Common, Frame R-ll
3: Common, Masonry R-3
Under Attic R-30
en Single Assembly; Enclosed
C!J Frame R-19
z
:J Metal Pans R-13 a.-t~
w Single Assembly; Open R-l0
() Common, Frame R-ll
en Slab-on-grade No Minimum --
II: Raised Wood R-ll
0
0 Raised Concrete R-5
...J Common, Frame R-ll
u.
I- In unconditioned space R-6 g,(o
()
:::> In conditioned space No minimum -
0
TABLE 6C-2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY
Maximum percentage glass to floor area allowed is selected by type, overhang length, and shading coefficient. Maximum%- Installed %- /.7
GLASS TYPE, OVERHANG, AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED
UP TO 20% UP TO 30% UP TO 40% UP TO 50%
Single Double Single Double Single Double Single Double
OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC
1'-1.0 0'- .90 2'-1.0 1'- .90 3' -1.0 2'-.90 4' -1.0 3'- .90
0'- .86 1'- .86 0'- .70 2'- .86 1'- .70 3'- .86 2'-.70
0'- .65 1'- .65 0'- .50 2'- .65 1'- .50
0' -.45 l' -.45 0'- .40
0'- .35
SHGC or SC may be obtained from the manufacturer. Single clear SC = 1.0, double clear SC = .90, and single tint SC = .86. SHGC .;- .87=SC
TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES
COMPONENTS SECTION REQUIREMENTS CHECK
Exterior Joints & Cracks 606.1 To be caulked, aasketed, weather-stripped or otherwise sealed. t./
Exterior Windows & Doors 606.1 Max. 0.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. V
Sole & Top Plates 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. .........
Recessed Lighting 606.1 Type IC rated with no penetrations (two alternatives allowed). -
Multi-story Houses 606.1 Air barrier on perimeter of floor cavity between floors. --
Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion
devices with integral exhaust ductwork. _.
Combustion 606.1 Combustion space and water heating systems must be provided with outside combustion air,
HeatinQ except for direct vent aooliances. --
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) --
or cutoff (aasl must be orovided. External or built-in heat trao reauired.
Swim"rning 612.1 Spas & heated pools must have covers (except solar heated). Non-cornmercial pools must have a -
Pools & Spas purnp timer. Gas spa & pool heaters must have minirnum therrnal efficiency of 78%.
Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units). -
Shower Heads 612,1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. -
HV AC Duct 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
Construction, sealed, insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be V
Insulation & Installation insulated to a minimum of R-6.
HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. --
GENERAL DIRECTIONS:
1. On Table 6C-1 indicate the R:value of the insulation being added to each component and the efficiency levels of the equipment being installed. All R-values and efficiencies installed must meet or exceed the minimum values
listed. Components and equipment neither being added nor renovated may be left blank.
2. ADDITIONS ONLY. Detennine the percentage of new glass to conditioned floor area in the addition as follows. Total the areas of all glass windows, sliding glass doors and glass door panels. Double the area of all non-
vertical roof glass and add it to the previous total. When glass in existing exterior walls is being removed or enclosed by the addition, an amount equal to the total area of this glass may be subtracted from the total glass area.
Divide the adjusted glass area total by the conditioned floor area of the addition. Multiply by 100 to get the percent. Rnd the largest glass percentage under which your calculated percentage falls on Table 6C-2. Prescriptives
are given by the type of glass (Single or Double pane) and the overhang (OH) paired with a shading coefficient (SC). For a given glass type and overhang, the minimum shading coefficient allowed is specified. Actual glass
windows and doors previously in the extenor walls of the house and being reinstalled in the addition do not have to comply with the overhang and shading coefficient requirements on Table 6C-2. All new glass in the addition
must meet the requirement for one of the options in the glass percentage category you indicated. The overhang (OH) distance is measured perpendiculany trom the face of the glass to a point directly under the outennost edge
of the overhang.
3. RENOVATIONS ONLY. Replacement glass needs to meet the following requirements. Any glass type and shading coefficient may be used for glass areas which are under at least a two foot overhang and whose lowest
edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single-pane tinted, double-pane clear or double-pane tinted.
4. BUILDING SYSTEMS. Comply when new system is installed for system installed.
5. Complete the infonnation requested on the top half of page 1.
6. Read "Minimum Requirements for Small Additions and Renovations", Table 6C-3, and check all applicable items.
7. Read, sign and date the "Owner/Agenr' certification statement on page 1.
-2-
~
I ,r-
B
-f---
, It
10Lo
-t-
20~{)"
(~
-t--
. ~
--~---'---'-"-'_.-
...-._-_._.-~-----_.-
------
-......--..
. .....-_...._--~--""".._- - ..~_...- -
- -
- ..." --- ~
-_.....--...-.
I
i
I :
\
",- ...- - '
-~
------
----~~--.-
~"-'-' ---..
~"""' ==-----
-.,------~---------=== ---~
1
---- -----l
' (8'
\<?,)I. L ~
.
r
1
\
1 )I. il
2'y4 STL~D 16 DC
fp,:t-f'\ \ L '.; P_ C)O ~ \i
131-111
~ .=~
r__......-..~....~~.....~
~'c t
A I "
{4--0
QlTfJ2\ at<. we
gD'~G
T\1f;k\'f;AL. 8PQQIE
,._-----.............--.---""""~~---........._-_.
-----------
-_._~
LJ E ..sr___EL-~~~:.t.101'--.J
J=~4Q&lB._~~~_\t~-::D~
LIVING \-<()c')~"n
.
,
T .. . .----- ---
_h.
I :
i
, ,
I
, ,
0 I
;
I ,
P
--
~ _..:.~__._ _...._ .4_""_"_' .,1..,____ ~
- ., .." .- ..
RETljeN AIK C;'21lL
..-_.-.-.... -- A/C'^;1JH1.1' REG\~ \ERS
-~
.. :1 .... ~ '---- .
Fir---': --@ I.
-,
-..........-.---
.~
. ... , ,
."'.
~
D
~i
-'\
. f_~~J~
()
s
E
T
I \
CECTI6N C-(~
,.::)... , ,-'---.......-._......-'---'_..-:::=::::
601 _ 0"
..
I 5 ~ 011
'3l'-1OtD \ N <S Nc
&:D gdC3Vl
F"AN)\L'I RO~
Q,O ~ o.
FA.110
ta~o
._-----------~...........-
," ~1J'WL
~\;Y~ l"Jl6'1 vt 'v (\lvl'
t) . ~r . /Jl,~\\-i
IJU;f r7 fI ~ () \
I "r f{
l..yf
CJ'
1
\
I
~)(I<ST ING UJA.LL
, ..
8-.0
I "
40-0
( "
S~r(a~ ,,~-=-_~___,
Sr1OWIN3 ~~~~~
-# 1\
~' 12.\ L P LA:11:. S -;. \ U.J
=:c_eEWS
b<\S"lING ~LOOe J{)\S\
II
22>'- 0 -
T
~t---'-----'--"'
2i-o"
9'-04
--,-~ --- --
51 II
j I
/
II
'2.~x41\ PI SllitJWALL ,~ a.c.
(
\
(J
\
.'.....,
~)(iER\oe ?~ S\D\I'G
3D PEQ - G '?j...rSi2 TH' B2(fl ~L f3j.."-J2 '(:( \ ER
'"
_ \-\ ~~cAN 1:: t>-NC.MC~QS "n~
.- II if ((I A.r-t t.:l.t=".u~n.\ 12];l2:. SP,EC
)8 + ~t/-b
I
SECTl 0 ~_C.~L::__D_
I I(
I~ OR'iWA-LL
----
\<NEe 0t\LL
LoN c.Q.ETE TO ~ EEl R.L:Q \DI\ ('.6r'i\=
INSTAlLED gy c~,trRAcrOR
\=\eERGLA~
\
V4('l('~/' ecc15 oR-T..BCL"T's \N",o
c-~02E-re SLAg. A"T '24l' ON C.EtHl:\<
tu I TH \/~Il)<. \ 1/2'1 UJA.SH-EE$;
( II
~-o +
~ ,
"
"
---J
~, . t? "r~ ~ 0
'~"'IO
~ ~ . (
D ";I C
."&
. - ------------
C\')~ ~ r"" --ill
I '.
,___, ~g~TI _Qt::L6 =.t~,-_
~o
SIDEWALk
'l>
~
"
\ N\'<.. ~ ~ f\ \..... ? ~ \<.. '\ \'0 N
(?~
--+-
14!-o'
-- I
c:rrV<J.>.J~ E:.
t 5 ( - 0(1
2.4-0"
<3'<3/-0/1
- -4-
__L~
=-==F I
-r
-------: ,
,.9
;:::.0
.-:r-
~
,../)
"
()
AIK' CON.TI \T((~N \\'~6
E)(\s'r\l':~~G. 'Sl)PPl..:1 Cd \Lt,.. 13E 'TEl:::.)
I.!,) \Tt\ ('2)1 Dt R IN 5ULAlED 0 UCT 8-
.'":'")/ 'N _.~o 2 -. I ? II y...cf! ~G\S\T.;-r::s;, \l.,.j
I'\. I-l I .. \ ----
. , .' ~--: \ \\ .. .." \ r /', ._\ I::: -L",
'.,<NEE LJ..J~L,L .'-~":': "., ~_. '-...,,-, -..-- ,..\
t;:"--:- ,(. I c~ ! l>- ',r:..; i=? F-' ,.."
~_.. t'. --.J \ ~ .......... "._- , --, ..
":~:jl.."j::.T" ~.~ \ : \.. ~',._
2..C~ T"'-:E:-~~ U,) - 'n-',
: ...~\Ii" . .., /,.... -\.' ("__)_' i-",
I, n ~.J, (.., I l,eLl,,-'! \ t:: L...I
112 Ii n
i "'';( "(,,,\,,.:::r ;;:::;' I, \ t.' (- Q0;'" [) ReID Rt---l A 11,
l....J ---J \_ ~,\....~._'~ . ........"'"'-1
GK1LL As I f..J '"D tCATED
ELEC~\CI>'\\", 'h' i C 1\2C0 \-r CA.) li"-\ ~Vt='"N
~P.:lLt:.. cu.5T Lt;;:..,S, 2 OlJ"\-L t::Ys:.
c.C\t-...\iRoLLEt.J FRDfl'\ SUj \Tc..~4 - 20ANlP NQ12
lU IRE..
I,.
SITE PLAN
;:)/, I( ;.t /1
'-)" = \ - 0
.1
I
r- '2-0-,..
~J""'\1\~5 1U
~f'\' """'<T ~ -
r~ c \Ob 7
-
FJJI
I(
,~--o
~ oo~ OIl
I .
_~ -L
~~
-;
. ~<ti\
,.),~ ~~~
);.> 'J\Q~".
\\\ \
LEGEND
...;>'
tH E. P Vc 5\ DI H(~ (J,J I LL \3.E:. ';:<,,~..~~tnc) (JEO
\'::00"-0. ~\- \'f:- "l-Ir'\-Y-YT\ ( \ ^'\ L \\ 'C' \'i"'."- ..-,......
~- N \' I \ t- c. I '\~..,}",_ \ '\"'\ .)_If-''.L.. "'-I,:::.:l ..J.) l':::_ 11"" \\ ~,
r:-: il .', I " ". " ct fJi .... ,.. ,. .__, "'\"' .
r,.,\< \\1, "I i<O(j\~ q.. \\.t'1"':tl-(..,I=::',L.) DJ \ \ H
Di<_Y lD/'>.,Lj~, I kY\LL a ~rot=- Co N-,c:;\kbCTl (~t'.~
-:,-D ~f\EJ:-'\- 1\ I.J, kJ~LEV/+.(T r-:. (\k!n,"~;'
rClDES
PA"KLtL U:). 03 -26-2\- 0 \3l)~. t.JOOc) ,-'c>-7~;j..:)
........<>-.....---..-
T~oo~,n f~L~L' \""\-lON "ro Nlo91LE
HO~H:.:@ 37GS\ NEGjPo,~'T' DR
7.EF..)\--\YR~-\'\LLS FLORIDA
DRN BY:...... Rt'<)c \
~..o'
0ATt=: ~ "' \0/'2.8/03
~"'"--..,~---------.....-