HomeMy WebLinkAbout04-2702
/.
I
CITY OF ZEPHYRHlllS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
2702
Permit Number: 2702 Issued: 2/03/2004 i
Permit Type: NEW SINGLE FAMILY DWELLING:
Class of Work: 101-NEW CONST/SFR I
Proposed Use: SINGLE FAMILY RESIDENTIAL
Sq, Feet: Est. Value: I
Cost: 97,100.00 Total Fees: 3,280.221
Amount Paid: 3,280.22 Date Paid: 2/03/2004
Address: 37508 LAUREL HAMMOCK DR
ZEPHYRHILLS, FL.
Township: Range:
lot(s): Block: Section:
Book: Page:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number:
Name: RYMAN CONSTRUCTION CO., INC.
Addr: 37325 SR 54 WEST
ZEPHYRHILLS, FL 33541
Phone: (813)782-0825 lic:
Work Desc: SINGLE FAMILY DWELLING
RYMAN CONSTRUCTION
37508 LAUREL HAMMOCK DR
ZEPHYRHILLS, FL. 33542
Phone:
U
WATER CONNECTION RESIDENl
RADON
1,
71.90 BUILDING FEE
I
180.00 I
t /,/10/01
'f~
I-1ST ROUG
I CONSTRUCTION POLE 2ND ROUGH PLUMB lDUCTS INSULATED
I PRE-METER i WATER FINAL MECHANICAL
o MISC I SEWER I MISC
INSULATION WALLVl{..q-otf .<!':fl MISC MISC. I MISC.
INSULATION CEILING I MISC. I MISC, , MISC.
DRIVEWAY MISC. I MISC, i FIRE DEPT, FINAL
-----~---=_L .
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
I'
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs~c~io s not mar~n
I inspection called (d) Work not ready for inspection when called , '
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible ..L ~ /0 _
lAo/IV
The payment o!!!1spection fees shall be made before any further permits will be issued to the person oWn' same .
"Warning to owner: Your failure to record a notice of commencement may result in your pa mg. r
i improvem~nts to your property. If you intend to obtain financing, consult with your lender ran y
~. before redording your notice of commencement. II , '___
/-i-----,-------- . -- - NO OCCUP~N_cy BEFORE C.O. ~
, RJ- .
~j Ut1u qA)~
(/ Jt~~!
SIGNATURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
APPLICATION FOR PEBMIT
CITY OF ZEPHYRHILLS
BUILDING DEPARTMENT
DATE RECEIVED
PLANS REVIEW FEE
OWNER'S NAME ~'ll4\.M ~NS\\L~\lC)N
JOB ADDRESS 3~ LA\k~ \-\-Pr\1\t-1l.~~\.'- ~\ll
, I
LEGAL DESCRIPTION: LOT (S) ~ l.o BLOCK
PARCE~ ID # 2>4 - 2.:s ~21-0\~-~ - al~
PHONE ,82... 08~
\ Z ~ 9 tt~ R.. \\\ILs.
SUBDIVISION ~~~
(OBTAIN FROM PROPERTY TAX NOTICE)
i ~EW CONSTRUCTION
WORK PROPSED: o ADDITION OALTERATION o REPAIR o INSTALL
Os I GN o MOVE 0 DEMOLISH
PRopdsED USE:~GL FAMILY DWELLING OMULTI-FAMILY 0# OF UNITS o MOBILE HOME
o COMMERCIAL o INDUSTRIAL o SWIMMING POOL o OTHER
~
BUILDING SIZE
c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL
CC)r{~~ ~<l:.\N .~"'~\) S\KJo~ ~~1
~ X ~ r SQUARE FOOTAGE \34-2.
~"'-l
HEIGHT B1 WN-L-$
DESCRIPTION OF WORK
RESIDENTIAL:
COMMERCIAL:
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS,
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS,
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION,
i;t'BUILDING
~ ELECTRICAL
~ PLUMBING
~MECHANICAL
o GAS 9lROOFING
PERMITS REQUESTED
&J, ~, CO VALUATION OF TOTAL CONSTRUCTION
,
$
2CO
AMP SERVICE
~ FLORIDA POWER
o W,R,E.C,
$
2 &:a ~CX:J
\
VALUATION OF MECHANCIAL INSTALLATION
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: ~ BLOCK 0 FRAME
If
FINISHED FLOOR ELEVATIONS 8 ~~ ~~
~F~b
o STEEL
o OTHER
IS PROJECT IN FLOOD ZONE AREAO YES
~NO
BUILDER COMPANYRYMl\N eONaTRUeTIO~J, UIe
~ STATE CERT OR REGIST # C'BC'-035J 3L1
SIGNATURE- . CITY PROCESSING # 274
... ~ * * ****** ** * * * * * ** * ** ** * * ** * * **** * ***** * * *** ** * * * ***** ** *
ELEC$UCIAN
SIGNATUREq~
~~~~
,
COMPANY E~ST PASCO ELECTRIC
STATE CERT OR REGIST # ER-0014591
CITY PROCESSING #
******************************************************************
PLUMBER
;
SIGNATURE~ ~ ~
COMPANY DENNIS WILLIAMS
STATE CERT OR REGIST # RF-05260
CITY PROCESSING #
* ** * * * * * ***.* *** ******** * ** *** * * *** * ** * * *** * * * *** *** *** * * * ** *** * * **
MZCHAm~ ~ COMPANY 'R?flR~ G?S HID ~/C'
, STATE CERT OR REGIST # CAC-043498
SIGNATURE ' ,,-" c.....'4--..:....f-.; CITY PROCESSING #
-
*****************************************************************
O~
SIGNA
COMPANY RYMAN CONSTRUCTION. TNC_
STATE CERT OR REGIST # RC-0061648
CITY PROCESSING #
*******
********************************************************
S~~R OR AGENT
STATE OF FLORIDA
COUNTY OF
The foregoing inst
Befor e this
by 'eO
(~ame of person acknowledged)
~o is personally known to me, or
A, NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be
may be more restrictive than City regulations, The
compliance with any applicable deed restrictions,
B, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations, If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-788-6611,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which they
will be responsible, If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work, If the contractor wishes
you to sign as contractor that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills,
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D, CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs, If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement,
E, CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development,
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction, I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance, Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U,S, Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A,etc,", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance,
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00, The extension shall be requested
in writing to the Building Official, An approved inspection must be logged during each six
month period, or the' project will be considered abandoned,
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT",
C ~1;
S~T RE, ONTAACT~,
O~
subject to "deed restrictions" which
undersigned assumes responsibility for
acknowledged
~3
acknowledged _/
,~~
ame of person acknowledged)
is personally known to me, or
o who
~..' ~ Bob
Name typed, iIi;~~~r=3
~..,\.t:
o who has produced -
(type of identification)
JJKd no t~~
acknowledgment
Name typed,
'''''"-
Ryman Construction
lot #16 laurel Hammock Dr.
SQ, FEET PRICE
MAIN OR LIVING: 1,942 $ 50.00
OTHER AREA UNDER ROOF: - $ 25.00
OTHER: - $ -
VALUATION $ 97,100.00
FEE SHEET $ 472.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 768.00
CREDIT: $ -
BUILDING LESS CREDIT: $ 768.00
ELECTRICAL: $ 106.40
PLUMBING: $ 99.50
MECHANICAL: $ 71.90
RADON: $ 19.42
TOTAL $ 1,065.22
SEWER: $ 1,616.00
WATER: $ 419.00
IRRIGATION: $ -
TOTAL: $ 2,035,00
I
I
WATER METER:I $
IRRIGATION METER $
180~00 I
SUB-TOTAL $
3,280.22 I
SIF'S: $ 1,694.00
97.5% $ 1,651.65
2,5% $ 42,35
T IF'S: $ 1,588.00
99% $ 1,572.12
1% $ 15.88
TOTAL: $ 6,562.22 I
I
Uc t . L J. L U U L I L :) ~ ~ M C I I Y U r L t ~ H Y K H ! L L ~
ciTY Of' ZEPIII.R.lULLS BUILDING DBPARTHBHT
'l2.", n-AI{ ~t{St1L,~,(.\ \~ N
L~\" \\0 l ~~L. ~\1\'\1\~~ j)P-\~1 ~t.."ij.L~
PARCEL LD,' # 3>4.... 2..5-'2.\ - O\QC - ~ - OltoG
NO.Lb/U
r'. III
OWNER
JOB LOCATION
suow ALL BXISTInG & FROPOSKD STRUCTURES GIVING DIH8NSIOHS & SETBACKS.
15
l\- 4- I
}-
WESTr.?:>U.P-f li
I
\\S
\~
\0 '
UTILITY BUILDINGS
HUST SHOW SIZE &
FOUNDATION INFOR-
MATION.
STREE'r
,S
L~ w.~~~ ::D\U~
(NOTE EXAMPLES 1 ~ 2)
1. SBTBACKS FO~ Rl, R2 ZONING
60'
2. SETBACRS FOR R3 ~ONING
60'
10'
P E
R 11:
0 I
10' p s 10'
0 'I' 1 0'
S I
E N
D G
'20'
FROHr PROPERTY LINE
10'
10' EXISTING 10'
PROPOSED
20'SGL FAH 30'DUPLRX
1 0'
FRONT PROPERTY LINE
Ft9HM 600A-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Westbury 2
Project Name:
Address:
City, State:
OWner:
Climate Zone:
Lot #16
Central
1. New construction or existing
2. Single fiunily or multi-fiunily
3, Number of units, if multi-family
4. Number of Bedrooms
5, Is this a worst case?
6, Conditioned floor area (ft2)
7, Glass area & type
a, Clear glass, default U-factor
b, Default tint
c, Labeled U or SHGC
8, Floor types
a, Slab-On-Grade Edge Insulation
b, N/A
c, N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. N/A
c, N/A
d, N/A
e, N/A
10. Ceiling types
a. Under Attic
b, N/A
c. NlA
11. Ducts
a, Sup: Unc. Ret: Unc, AH: Garage
b. N/A
Single Pane
0.0 iF
117.8 f1'
0.0 ft2
New
Single family
1
3
No
1477 ft2
Double Pane
0.0 ft2
0.0 ft2
0,0 ft2
Builder: Ryman
Permitting Office:
Permit Number:
Jurisdiction Number:
12, Cooling systems
a, Central Unit
Cap: 30,0 kBtulhr
SEER: 11,00
R=O,O, 171.0(p) ft
R=5,5, 1368.0 ft2
R=30,O, 1942,0 ft2
Sup, R=6.0, 350,0 ft
b, N/A
c. N/A
13, Heating systems
a. Electric Heat Pump
Cap: 30,0 kBtulhr
HSPF: 7,50
b, N/A
c, N/A
14, Hot water systems
a, Electric Resistance
Cap: 30,0 gallons
EF: 0.97
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15, HVACcredits W@ rN /c2
(CF-Ceiling fan, CV-Cross ventilation, D \.::7 L5 D \}7 @
HF-Whole house fun,
PT-Programmable Thermostat, JA N 1 5 2004
MZ-C-Multizone cooling,
MZ-H-Multizone heating) l By
=---
Glass/Floor Area: 0.08
Total as-built points: 20659
Total base points: 22694
PASS
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code. -/
PREPARED BY: _ 9~ ~
DATE: I. IS' c/'-f
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908 ~ ~
Florida Statutes. OOl)Wf.~
BUILDING 4FFICIAL: -11~ ~ ..:'
DATE: JAil/If
~n'::>r""r::",,,,,oI&l (\lor,,;nn' ~I Rrp!:l ",< ,<n\
FORM 600A-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: · · ·
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points
.18 1477.0 25.78 6853.9 Single, Tint N 1.0 6.5 14,2 24.46 0.98 339,5
Single, Tint N 1.0 6.0 18.7 24.46 0.98 445.8
Single, Tint S 1,0 6,0 16,2 39,84 0.95 610,9
Single, Tint S 1,0 3,0 4.8 39.84 0,80 152.0
Single, Tint S 1.0 6,0 8.4 39.84 0,95 315.8
Single, Tint S 1.0 6,0 23.2 39,84 0.95 876,9
Single, Tint E 1,0 6.0 16,2 53.27 0.97 836,9
Single, Tint W 1.0 6.0 16.2 47.90 0.97 752.4
As-Built Total: 117.8 4330.1
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 0.0 0.00 0,0 Concrete, Int Insul, Exterior 5,5 1368,0 0,95 1299.6
Exterior 1368.0 1.90 2599,2
Base Total: 1368.0 2599.2 As-Built Total: 1368.0 1299.6
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Insulated 20,4 4,80 97.9
Exterior 20.4 4,80 97,9
Base Total: 20.4 97.9 As-Built Total: 20.4 97.9
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 1477.0 2.13 3146,0 Under Attic 30,0 1942,0 2.13X 1.00 4136.5
Base Totlill: 1477 .0 3146.0 As-Built Total: 1942.0 4138.5
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 171.0(p) -31.8 -5437.8 Slab-On-Grade Edge Insulation 0.0 171.0(p -31.90 -5454.9
Raised 0,0 0,00 0.0
Base Total: -5437.8 As-Built Total: 171.0 -6464.9
INFILTRATION Area X BSPM = Points Area X SPM = Points
1477,0 14.31 21135.9 1477,0 14,31 21135.9
I=nOr.t"l\""'~llnot6'\ nr:A I=nrn"'l ~4_"""'1
I=norn\l~211,.,Q/'il)/1=12J:)1=~'?I'Vl1 1=1 J:)r:P~ \~ ~n
, FORM 600A-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUlL T
Summer Base Points: 28395.1 Summer As-Built Points: 25545.1
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
25545,1 1.000 (1.087 x 1,150 x 1.(0) 0.310 1.000 9899.1
28395.1 0.4266 12113.3 25545.1 1.00 1.250 0.310 1.000 9899.1
~na.rl'l\/f':1~llnQTM nrA ~nrt'n '::;;noA_"nn1
J::"Ar,.n~~lIn.alR)/J:I~J:)1::c::.1.,nn1 1=1 QrCI=f: \I'=t ~
FGRM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: II I
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WaF = Point
.18 1477 .0 6.86 1667.9 Single, Tint N 1.0 6.5 14.2 15.38 1 ,()() 217.3
Single, Tint N 1,0 6.0 18.7 15.38 1.00 286.7
Single, Tint S 1.0 6.0 16.2 10,88 1,01 177.5
Single, Tint S 1,0 3.0 4.8 10.88 1.12 58,1
Single, Tint S 1,0 6,0 8.4 10.88 1.01 91.8
Single, Tint S 1.0 6,0 23.2 10.88 1.01 254.8
Single, Tint E 1,0 6.0 16.2 13,04 1,01 212.8
Single, Tint W 1,0 6.0 16,2 13.80 1.00 223.9
As-Built Total: 117.8 1622.8
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 5,5 1368.0 2,75 3762.0
Exterior 1368,0 2,00 2736,0
Base Total: 1368.0 2736.0 As-Built Total: 1368.0 3762.0
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 O. ()() 0.0 Exterior Insulated 20.4 5,10 104.0
Exterior 20,4 5,10 104,0
Base Total: 20.4 104.0 As-Built Total: 20.4 104.0
CEILING TYPESArea X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 1477.0 0.64 945.3 Under Attic 30.0 1942.0 0,64 X 1,()() 1242.9
Base Total: 1477.0 946.3 As-Built Total: 1942.0 1242.9
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 171.0(p) -1.9 -324,9 Slab-On-Grade Edge Insulation 0.0 171.0(p 2.50 427,5
Raised 0.0 0.00 0,0
Base Total: -324.9 As-Built Total: 171.0 427.6
INFILTRATION Area X BWPM = Points Area X WPM = Points
1477.0 -0,28 -413.6 1477.0 -0.28 -413.6
~nCor"\I~AllnAt'R\ nr A ~nnn ~lL?tVl1
a::nCllrn\l~'l:Illnalfi\11:'121:ita::~',)fV\1 1:1 1:::>('01:1 \I~ 'Ul
FGRM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUlL T
Winter Base Points: 4604.8 Winter As-Built Points: 6645.7
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
6645,7 1,000 (1,078 x 1.160 x 1,(0) 0,455 1,000 3781.7
4604.8 0.6274 2889.1 6645.7 1.00 1.250 0.455 1.000 3781.7
CnAr""~2Itno.TM nf'A ~nrrn ~A_")f\()1
J=nQ.rn\t~..:u InatR'\/~I!:IRJ:~'?nn1 1=1 Dr"PI=I: \t"=t ~
FORM 600A-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS:" ,
PERMIT #:
BASE AS-BUlL T
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2564.00 7692,0 30,0 0.97 3 1,00 2326.10 1,00 6978.3
As-Built Total: 6918.3
CODE COMPLIANCE STATUS
BASE AS-BUlL T
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points Points Points Points Points Points
12113 2889 7692 22694 9899 3782 6978 20659
I
PASS
I
I:n.Qrn\l~":2II".oTM nl'A ~nrrn ~nnA_~nn1
~nor"\I~-=-llnot1S'l/~b~I=c::."")(l(l1 ~I J::trPR \~ ~
FORM 600A-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
I ADDRESS: · · ·
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
PERMIT #:
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows & Doors 606.1.ABC,1,1 Maximum:,3 cfm/sa.ft. window area' ,5 cfmlsa.ft. door area,
Exterior & Adjacent Walls 606.1.ABC,1.2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the too olate.
Floors 606.1,ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the oerimeter oenetrations and seams,
Ceilings 606.1.ABC ,1 .2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the oerimeter at oenetrations and seams,
Recessed Lighting Fixtures 606.1 ,ABC,1 ,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
conditioned soace tested,
Multi-storv Houses 606.1,ABC.1.2.5 Air barrier on oerimeter of floor cavitv between floors.
Additional Infiltration reqts 606.1.ABC.1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences,)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit
breaker (electric) or cutoff (cas) must be orovided. External or built-in heat trao reauired,
Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiencv of 78%.
Shower heads 612,1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG.
Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min, insulation,
HVAC Controls 607,1 Seoarate readilv accessible manual or automatic thermostat for each sYStem,
Insulation 604,1, 602.1 Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides,
Common ceiling & floors R-11.
I:norn,,f'':!-Allna™ nr4 I=nrrn ~4_?fV\1
t:n.o.r",/~'!:III"atfi\/I:'I'!:II:)t:C:I~tv\1 ~I QrOI:l ,,t::l ~n
-ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE" = 84.9
The higher the score, the more efficient the home,
1, New construction or existing
2, Single family or multi-family
3, Number of units, if multi-family
4, Number of Bedrooms
5, Is this a worst case?
6, Conditioned floor area (ft')
7, Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tinllother SHGC - single pane
d. Tinllother SHGC - double pane
8, Floor types
a, Slab-On-Grade Edge Insulation
b. N/A
c, N/A
9, Wall types
a. Concrete, Int Insul, Exterior
b, N/A
c, N/A
d, N/A
e. N/A
10. Ceiling types
a, Under Attic
b, N/A
c, N/A
11, Ducts
a. Sup: Unc. Ret: Unc, AH: Garage
b. N/A
Single Pane
0.0 ft2
117.8 ft2
0.0 ft2
New
Single fumily
1
3
No
1477 fF
Double Pane
0,0 ft2
0.0 ft2
0.0 ft2
Lot #16, , , ,
12. Cooling systems
a, Central Unit
Cap: 30,0 kBtulhr
SEER: 11.00
R=O.O, 171.0(p) ft
R~5.5, 1368,0 ft2
R~30.0, 1942,0 ft2
Sup. R=6,O, 350.0 ft
b, N/A
c. NlA
13. Heating systems
a. Electric Heat Pump
Cap: 30.0 kBtulhr
HSPF: 7,50
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 30.0 gallons
EF: 0.97
b. N/A
c, Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HV AC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fun,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certifY that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on install~ T:I~ant features.
Builder Signatur~: ~ \Lt\l \~ ~'1't1\I\r{ Date: l/2-o/04
Address of New Home: ~e5L ~M\tlL ~~~~
*NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program.
This is nat a Building Energy Rating. lfyour score is 80 or greater (or 86 for a us EPA/DOE EnergyStcfJ:! designation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site atwww.ftec.ucfedufor
informati'pn and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department afCommunity Affairs at 850/487-1824.
Ener~auge@ (Version: FLRCPB v3.30)
Residential System Sizing Calculation
Summary
Project Title:
Westbury 2
Lot #16
Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M)
Humidit data: Interior RH 50% Outdoor wet bulb 6F Humidit difference 44 r.
Winter design temperature 38 F Summer design temperature
Winter setpoint 70 F Summer setpoint
Winter tern rature difference 32 F Summer tern erature difference
Total heatin load calculation 21140 Btuh Total coolin load calculation
Submitted heating capacity % of calc Btuh Submitted cooling capacity
Total (Electric Heat Pump) 141,9 30000 Sensible (SHR = 0.5)
Heat Pump + Auxiliary(O.OkW) Latent
Total lectric Heat Pum
Winter Heatin Load
Load com nent
Window total
Wall total
Door total
Ceiling total
Floor total
Infiltration
Subtotal
Duct loss
TOTAL HEAT lOSS
Summer Coolin Load
Load com onent
Window total
Wall total
Door total
Ceiling total
Floor total
Infiltration
Internal gain
Subtotal(sensible)
Duct gain
Total sensible gain
Latent gain(infiltration)
Latent igain(internal)
Total atent gain
TOTA HEAT GAIN
WINTER CALCULATIONS
118 sqft
1368 sqft
20 sqft
1942 sqft
171 ft
99 cfm
Load
3770
6019
307
2136
4429
3473
20134
1007
21140
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Code Only
Professional Version
Climate: Central
93 F
75 F
18 F
18806 Btuh
% of calc Btuh
101.1 15000
378.5 15000
DUDr8(1 %)
SUMMER CALCULATIONS
ft
118 sqft
1368 sqft
20 sqft
1942 sqft
86 cfm
Load
3157 Btuh
2663 Btuh
207 Btuh
2758 Btuh
o Btuh
1709 Btuh
3000 Btuh
13493 Btuh
1349 Btuh
14843 Btuh
2583 Btuh
1380 Btuh
3963 Btuh
18806 Btuh
EneravGauoe<ro FLRCPB v3,3Q
Infil.(9%)
EnergyGauge@ System Sizing qased on A
PREPARED BY: ~
DATE: 1-15- 0'-/
Cetlings(15%)
"
Lot #16
System Sizing Calculations - Winter
Residential Load - Component Details
Project Title:
Westbury 2
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F
1/14/04
Window Panes/SHGC/Frame/U Orientation Area X HTM= Load
1 1, Tint, Metal, 1.00 N 14.2 32.0 453 Btuh
2 1, Tint, Metal, 1.00 N 18.7 32.0 598 Btuh
3 1, Tint, Metal, 1.00 S 16.2 32.0 518 Btuh
4 1, Tint, Metal, 1.00 S 4.8 32.0 153 Btuh
5 1, Tint, Metal, 1.00 S 8.4 32,0 268 Btuh
6 1, Tint, Metal, 1.00 S 23.2 32.0 744 Btuh
7 1, Tint, Metal, 1.00 E 16.2 32.0 518 Btuh
8 1, Tint, Metal, 1.00 W 16.2 32.0 518 Btuh
Window Total 118 3770 Btuh
Walls Type R-Value Area X HTM= Load
1 Concrete - Exterior 5.5 1368 4.4 6019 Btuh
Wall Total 1368 6019 Btuh
Doors Type Area X HTM= Load
1 Insulated - Exter 20 15.0 307 Btuh
Door Total 20 307Btuh
Ceilings Type R-Value Area X HTM= Load
1 Under Attic 30.0 1942 1.1 2136 Btuh
Ceilina Total 1942 2136Btuh
Floors Type R-Value Size X HTM= Load
1 Slab-On-Grade Edge Insul 0 171.0 ft(p) 25.9 4429 Btuh
Floor Total 171 4429 Btuh
Infiltration Type ACHX Building Volume CFM= Load
Natural 0.40 14770(sqft) 99 3473 Btuh
Mechanical 0 o Btuh
Infiltration Total 99 3473 Btuh
Subtotal 20134 Btuh
Totals for Heating Duct Loss(using duct multiplier of 0.05 1007 Btuh
Total Btuh Loss 21140 Btuh
Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint)
(Frame types - metal, wood or insulated metal)
(U - Window U-Factor or 'OEF' for default)
(HTM - ManualJ Heat Transfer Multiplier)
Key: Floor size (perimeter(p) for slab-an-grade or area for all other floor types )
EneravGauae<!i> FLRCPB v330
"
Lot #16
System Sizing Calculations - Summer
Residential Load - Component Details
Project Title:
Westbury 2
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults) Summer Temperature Difference: 18.0 F
1/14/04
Type Overhang Window Area(sqft) HTM Load
Window Panes/SHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded
1 " Tint, 1.00, B, N N 1 6.5 14.2 0.0 14.2 18 18 255 Btuh
2 1, Tint, 1.00, B, N N 1 6 18,7 0.0 18.7 18 18 336 Btuh
3 1, Tint, 1,00, B, N S 1 6 16.2 16.2 0.0 18 27 291 Btuh
4 1, Tint, 1.00, B, N S 1 3 4.8 4.8 0,0 18 27 86 Btuh
5 1, Tint, 1,00, B, N S 1 6 8.4 8.4 0.0 18 27 151 Btuh
6 1, Tint, 1,00, B, N S 1 6 23,2 23.2 0,0 18 27 418 Btuh
7 1, Tint, 1.00, B, N E 1 6 16.2 0.0 16.2 18 50 810 Btuh
6 1, Tint, 1.00, B, N W 1 6 16.2 0,0 16,2 18 50 810 Btuh
Window Total 118 3157 Btuh
Walls Type R-Value Area HTM Load
1 Concrete - Exterior 5,5 1368,0 1.9 2663 Btuh
Wall Total 1368.0 2663 Btuh
Doors Type Area HTM Load
1 Insulated - Exter 20.4 10.1 207 Btuh
Door Total 20.4 207 Btuh
Ceilings Type/Color R-Value Area HTM Load
1 Under Attic/Dark 30.0 1942,0 1.4 2758 Btuh
Ceilino Total 1942.0 2758 Btuh
Floors Type R-Value Size HTM Load
1 Slab-an-Grade Edge Insulation 0.0 171,0 ft(p) 0,0 0 Btuh
Floor Total 171.0 0 Btuh
Infiltration Type ACH Volume CFM= Load
Natural 0.35 14770 86,3 1709 Btuh
Mechanical 0 0 Btuh
Infiltration Total 86 1709 Btuh
Occupants
6
Btuh/occupant
X 300 +
Appliance
1200
Load
3000 Btuh
Subtotal 13493 Btuh
Duct gain(using duct multiplier of 0,10) 1349 Btuh
Total sensible gain 14843 Btuh
Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 2583 Btuh
Latent occupant gain (6 people @ 230 Btuh per person) 1380 Btuh
Latent other gain 0 Btuh
TOTAL GAIN 18806 Btuh
Key: Win(low types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint)
(U - Window U-Factor or 'OEF' for default)
(InSh - Interior shading device: none(NlirQ!i~Iil_'teRaigP8*~6hades(R))
, CITY OF
ZEPHYRHILLS
IINOTICE"
OF ADD.ITION OR CORRECTION
BUILDING
DEPARTMENT
DO NOT REMOVE
I ADDRESS DATE PERMIT -# I
3'75"08 ~II~ ~~ CUt - 'H-ell.j d'JOL
THIS JOB HAS NOT BEEN COMPLETED The following additiqns or corrections shall be made before the job
' will be accepted,
*<r~. ~t lb- k. ~j qJ.. tk..c.1,~A- ..1u::bt....J. J
~O..h~~~7~~QfU~_
:i-:~.m. ~ eLl. a-..~ '^h=n:;q)lJo1 ~ ~. ~. 1~/.3 ~.~ 1),5 CJJ, ~
*~~~~~~~~~{~llC1~~:bl
*1~4~~Jl~~,
It is unlawful for any Carpenter, Contractor, Builder, or other persons, to
cover or cause to be covered, any part of the wor1< with flooring, lath, earth
or other material, until the proper inspector has had ample time to approve
the installation,
AFTER CORRECTIONS ARE MADE CALL
780-0020 FOR RE-INSPECTION
INSPECTOR ~ ~ p.;::r-C
OFFICE HOURS 7:30 AM - 5 PM MON.-FRI.
, CITY'OF II N aT ICE' , BUILDING
ZEPHYRHILLS DEPARTMENT
OF ADDITION OR CORRECTION
I ADDRESS DATE PERMIT "" ]
W:<08:' ~J.~~ 4. N-I>.'t 2701- .
THIS JOB HAS NOT BEEN COMPLETED The following additiqns or corrections shall be made before the job
' will be accepted,
,
~ \ ..L
D-'L _
~d~~
~UJ< ~ f-~ ~ ~ In'''f- .J.U- /Y\Ah~
.~3~~/",-_ _ u
~~~~,:~!1!I~~eJ
DO NOT REMOVE
It is unlawful for any Carpenter, Contractor, Builder, or other persons, to
cover or cause to be covered, any part of the work with flooring, lath, earth
or other material, until the proper inspector has had ample time to approve
the installation,
AFTER CORRECTIONS ARE MADE CALL
780-0020 FOR RE-INSPECTION
INSPECTORc60 Id--r tJ
OFFICE HOURS 7:30 AM - 5 PM MON.-FRI.
.
.
~;ji;N.d.
.
.
.
.
.
.
.
.
.
WATER ACCT. NO.
OWNER/
RENTER
,;\
'1'<'-'1 ~V\
,
?ERFORMANCE BUSINESS PRe Due,s. NC. d13-719-8008 FAX 813-719-7919
("" ':).., af'.(") c-7'!
'" ~---, I ~ r
\,
CITY OF ZEPHYRHILLS
ZEPHYRHlllS. FLORIDA
DATE
e~,
,"0
L~p
~,,,, -,- /~-
, ./ - ;' ) t ,r
~ -
17 //, ..t f
Jhr...'-" 4! fl7~n)lri/.Cllc('. L~l.r.
~ATER
C SEWER
.L.J-r:
16
MAIUNG
/" -
0e..(,<.o
o
[[!//
Qr'/'
o GARBAGE
SERVICE ADDRESS
SHUT OFF SERVICE
TURN ON SERVICE
iNSTAll METER
READ METER
CHECK METER
OTHER
....,
-") I
,j
/1
I
/ .' .- ~
< :-....f
r
,
j !. \.,/-;;1/
f.,\J' \" .'
o
Q--/ iN CiTY
o
o OUT CITY
o
I
~ No. OF UNITS
_ DEPOSIT AMOUNT
-I
..-r-
lj1~ lor
- AMOUNT LAST BILL
_ DATE
_ MISC. CHARGE
I ~_;~E:;NBY r /
I f',' j ~RDER GIVEN B~,,' ~
i(12~~
Retain white form in office at all times, J
Send pink & yellow forms to Water Service Dept. '" /
Water Service Dept. to sign yellow form & return to office. --'
WORK COMPLETED BY
& DATE COMPLETED
~"~,~,,~j--,,
,.-.-,.-~.-...-,~~.,~,:,~,:;;.~"~,~~.~,,,--":_~-:.-..._,.-,,",-,.-..'-'-"-,,,--,,-,- _.-
\
)1-'1 {-l:"~
.; ".! (- ~ i-"-'~ i
l...!f',!l
'"i . i :~ - i
'Ii"
i I'"~
"': :,
:: (y \ .~:" ;
t :
J,
L l., q
;,; ('11'/:,; ;";~;J;
,j i
-'.J
i'
,::,pi' ,1,,:,.1
f.}' b
'i; !.J
',:1
\
" .:
".:.' .. (,I'
!j:
l
,+:,',':':
" I, !; I~:
, ,i
"j J :..ih "l.:'i: .<:
:'i
t.l../()
"'\' :;.
,.___ ___... ,,____ _.. .'___ .____, ."._. _,....1