HomeMy WebLinkAbout04-2784
~
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
2784
Permit Number:
Permit Type:
Class of Work:
Proposed Use:
Square Feet:
Est. Value:
Improv. Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
2784
ADDITION/ALTERATION
434-ADD/AL T RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
Address: 5430 18TH ST
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number:
25,000.00
3/03/2004
869.32
869.32
3/03/2004 I Phone:
ADDING GARAGE ANl= FAMILY ROOM AND BEDROOM
Name: SEAN & HEATHER ZIRBEL
Address: 5430 18TH ST
ZEPHYRHILLS, FL. 33542
D U I
I PRE-SLAB 01 I CONSTRUCTION POLE 2ND ROUGH PLUMB JfffDUCTS INSULATED
LINTEL PRE-METER ! WATER . FINAL MECHANICAL
FRAME MISC SEWER ' MISC
INSULATION WALL lMISC I MISC. MISC.
INSULATION CEILING MISC. MISC. MISC.
DRIVEWAY.. .~ISC. . . I MISC. , FIRE DEPT. FINAL
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record-it notice of commencement may result in your paying twice for
I improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
I before recording your notice of commencement."
r.--- ----.. . Complete Plans, Specifications and Fee Must Accompany Application. _.
All work shqU, be performed in accordance with City Codes and Ordinances
,~~ ~ -- --- NOOCCUPANCYBEFOREC.O. ~ .
.. Ii ~_
CT SIG ~TURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
NOTICE OF COMMENCEMENT
_.
State of -.iJo ~I b A County of ?A?CO
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,
and in accordance with Chapter 713, Florida Statutes, the following information is provided in
this Notice of Commencement:
1. Description of Property: Parcel No. /I-';?/v-of/- OO/()- 11500-{)J76
5if.7() 18f-h 5T 2Ef?H~I2I-JJ U~
(Legal description of t e property and street address if available)
2. General Description of Improvement A6 /j} 7/~AJ -::. ~6~ / f/hsfr:=fi. f3-ecl1OJ~jif) I ~-' i)
1111111111111111I1111111111111111111111111111111111111111111
2004037437
/i:1o;d l/ If U(J/YJ
I
Owner Information: Name .5EAtJ ANi-::J J~ -rJ+F....A
2, J<BE. L
Address oL/Eb IBM S T
City&t'HY/<-rlJ LL5 State~L. 335t.j;).
Rcpt: 761124 Rec: 6.00
DS: 0.00 IT. 0 00
03/03/04 ___~ Dpty Clerk
JED PITTMANft PASCO COUNTY CLERK
03/03/04 1~:05am 1 of 1
OR BK 5749 PG 1113
City ,state
Interest in Property: 0'
Name of Fee Simple Titleholder: /V'IA
(If other than owner) ,
Address
4. Contractor: Name 5EI ~
Address 0" i? () /8' ..J. h .sT"'
City C<fh. vthi JI .5
/
State f!
5, Surety: Name
Address
City
State
Amount of Bond: $
6. Lender: Name
Address
City
State
7. Persons within the State of Florida designated by Owner upon whom notices or other
documents may be served as provided by Section 713.13 (1) (a) (7), Florida Statutes:
Name
Address
City
State
8. In addition to himself, Owner designates
of to receive a copy of the Lienor's Notice as
provided in Section 713.13(1) (b), Florida Statutes.
9. Expiration date of Notice of Commencement (the expiration date is 1 year from the date
of recording unless a d[:~r~ntdatei: speCIfie/~> f
SignatureofOwner:?<' /~&, ~ '
Sworn to and subscribed before me this 0~/ day of '-1Y\oJ\..Q..~ , 20 Cy--{ .
'-
Notary Publi '
....~r;.y.'}~ amY WILLIAMS
t.~' \;, MY COMMISSION # DO 058015
- . :-
'..
My Commission Expires:
PC93053048/ A
~ 2184
City of Zephyrhills Building Department
5335 Eighth Street
Zephyrhills, FL 33540
April 27, 2005
Dear Sirs and/or Madams,
It has come to our attention that we have missed the deadline for our inspection
that would have included framing, electrical, mechanical, and plumbing. I apologize for
the inconvenience this may cause the City Building Inspectors. I am a full time
hardworking husband and father of two. I have been working on this 1800 square foot
addition on my time off. Time off is hard to find; as I am sure you are all well aware of,
therefore this has been a weekend endeavor for the past year. My wife and I try very hard
to complete things on time, but we would appreciate your understanding in our inability
to make the deadline. It is our hopes that you will be able to extend the deadline; so as we
can complete what I know will be, not only an improvement for my family but our
Sean Zirbel
~vP
Gf' I d'
e.{ I ~)6
\)1M"
qa ..~/
IP (lJvJ1
neighborhood as well.
Zy
5430 Eighteenth Street
Zephyrhills, FL 33540
(813) 788-0185
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542
813-780-0020 FAX: 813-780-Q021
DATE RECEIVED
PHONE CONTACT FOR PERMITTING
OWNER'S NAME ~ Zlte.8E-L
JOB ADDRESS rH sr
LEGA.L DESCRIP. / ~ I ? -f- /9 BLOCK Iii}
PARCEL ID # I/-~(P-dl- On/()-IJ./ 5'00- ()/''7()
PHONE f3J 3-788- O/BS
SUBDIVISION
(OBTAIN FROM PROPER~X TAX NOTICE)
WORK PROPSED: ONEW CONSTRUCTION
OSIGN
. ADDITION
o MOVE
OALTERATION
D REPAIR
D INSTALL
o DEMOI,ISH
PROPOSED USE :){SGL FAMILY DWELLING
D COMMERCIAL
DMULTI - FAMILY
o INDUSTRIAL
D# OF UNITS
o SWIMMING POOL
D MOBILE HOME
D OTHER
DESCRIpTION OF WORK
D RESTAURANT & HEALTH DEPARTMENT APPROVAl,
1+6 tJ I III l-
~~
I1m/Lv,(!am .;- 8d~
/ ~ I &B
FOOTAGE I. 't) 7 ~ HEIGHT
BUILDING SIZE
SQUARE
RESIDENTIAL: ATTACH rJl1 PLOT PLANS & (~SETS OF BUILDING PLANS & ('9;1/ SET ENERGY FORMS.
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
PERMITS REQUESTED
E XI.5- //# b-
AMP SERVICE
jJc;{6
~ FLORIDA POWER
~>~.\
I I
/
./
W.R.E.C.
~ BUILDING
}(ELECTRIC1\TJ
$__c2r5' K
VALUATION OF TOTAL CONSTRUCTION
D
14 PLUMBING
D MECHANICAL $
o GAS jZ(ROOFING 0 SPECIALTY
VALUATION OF MECHANCIAL INSTALLATION
D OTHER
TYPE OF CONSTRUCTION: D BLOCK
);( FRAME
o STEEL
D OTHER
FINISHED FLOOR ELEVATIONS
IS PRO.JECT IN FLOOD ZONE AHEAD YES M NO
f:'l; ...
~'.,':if';,:.iJ
- "-~~0_'._ ,:j;-,t"r;,:.,"
;1;~2S
tr> j,J r-.vf .t::::,.-/ ,- ;.
t:OMPANY '-'C f- -
1lE1l7J-t&( /It Z/~BEL
BUILDER
SIGNATURE
ELECTIlICIAN /, / ~. COM~;""Y SID?
SIGNATURE I~ STATE CERT OR REGIST #
OTHER
*********************************************
PLUMBl!lR
I( c.-
COMPANY JEi I-
SIGNATURE
STATE CERT OR REGIST #
*******************************************
COM~hNy 8Ei;:-
SIGNATURE
STATE CERT OR REGIST #
~~******************************************
\ ,
COMPANY
fiEf;:
SIGNATURE
STATE CERT OR REGIST #
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITtES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", T cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR' S/OWNER' S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A,ete.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter reqlliring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized bY such permit is commenced vd thi n
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _ day of
by
acknowledged
, 20_
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _day of
by
acknowledged
, 20
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
[lho is personally known to me, or
of identification)
take an oath.
Dwho has produced
(type of identification)
and who Ddid OEd not take an oath
Dwho has produced
(type
and wrioD did Ddid not
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped
Heather M. Zirbel
5430 - 18th St.
SQ. FEET PRICE
MAIN OR LIVING: 1,807 $ 50.00
OTHER AREA UNDER ROOF: $ 25.00
OTHER: - $ -
VALUATION $ 90,350.00
FEE SHEET $ 444.00
ADDRESS $ -
DRIVEWAY $ -
BUILDING: $ 666.00
CREDIT: $ -
BUILDING LESS CREDIT: $ 666.00
ELECTRICAL: $ 65.75
PLUMBING: $ 59.50
MECHANICAL: $ 60.00
RADON: $ 18.07
TOTAL $ 869.32
SEWER: $ -
WATER: $ -
IRRIGATION: $ -
TOTAL: $ -
WATER METER:I $
IRRIGATION METER $
SUB-TOTAL $
869.32 I
SIF'S:I $
97.5% $
2.5% $
T IF'S :1 $
99% $
1% $
TOTAL: $
869.32 I
C. ,RED DEUEL & ASSOCIATES, INC.
5151 GALL BLVD.
ZEPHYRHILLS, ,LORIDA 33541
PHONE: (613) 762-6717
,AX: (613) 762-5426
/Z '/z "1
(I 0
1-13' (.,0.00'
I . O'
t .. v
~!.;;.'rt
,:;;Tt-J AVE'
10/." C02
BLOCK
,41.
^' W COINF~
6l0cK 1<15
30'
""
~
'-
"'
~
I:l
~
~
~
C
o
l::l
~
~ 20
k~
~
\tj , l
~I)..
II)~
~
~ :. ~
()
~'9
AI
2Ul
IJo.o'
laJ ., ""'
t;::"'L.
S~A.
to
.,;
...
;-..
~
l\:)
~ .,II'~
(p ~
01';'
~,P.
~.
/-I' /. (J.
Q'
\: "
\;\~ .
?',!l'.r\;':o-.
~. '" <t
/9.7' ~ ~
~~
'10
/40.00' e~I'M)
20' A ~~E"" (VA//_PROVED)
(40 00
-I
30'
\.~.
~.\\\
I'
~o
LEGAL DESCRIPTION
Lots 17, 18 and 19, Block 145, CITY
OF ZEPHYRHILLS, as recorded in Plat
Book 1, Page 54, Public Records of
Pasco CountYi Florida.
FOR: SEAN ZIRBEL
SURVEY DATE: . OG~ 9, 1998
BOUNDARY SURVEY
ORDER #12323-ZH
k0
\
L ~~'
..:./ i
,;,1')",
1\1)00"
"Il fll
~. II
vL'-, II, Ivvr. c-\V ..J.,I,(I'I\.7.C-1 C. ~
Pasco County, Florida
'~
W .' ';'~~~. '\ '- P,
. ""/" .......",-
V
s
Scale: 1" =30'
" -""~
o 15' 30
~o
(/<tNl)
LOII9
1;1'
'I.' :"
.3 ~
gO '-
NOT VALID UNLESS
EMBOSSED WlTI-l A SEAL
THIS STAMP IS RED
Ce/l.T/r/EO '/0'-
. SUA/c.o.-u-r SCHOOL FG'.oER-4L CREDIT L/N/ON
SC/IVSTA7"E TITLE
r/Rsr -"f/l4c,cz/C"lN T/TL.E
SGAN Z/R8EL
~~'/4
- Not valid without the signature and
the original raised seal of a Florida
licensed surveyor arxl mapper.
SURVEYORS 1l0'l'ES:
LeQend
IR) Pe,1.egal Descnptlon .' p..t
ICJ Calculdled
1~11 Field MedsurecJ
FI. R. Found Iron Rod
FI.P Found Iron P,pe
rCM. Found Concrete Monument
CI..F Cha,n Unk Fence
\II.F. Wlte Fence
\VD.F. Wooocn Fence
PI' Power Pole
a.H.1.. Overhead Une
,"O.B. POInt of Ileg,nn,ng
C.f' Edge of Pavement
f~. I.. POint on Une
HR. Set liZ' 'ran Rod Capped with LB# I 07
r.O.B. Top a/Bank
TO S. Taeo/Slope
Il/W.l/ R'ghrofWay
ro. C 1'0,01 of Commenccm(.nl
ZHCCL Zephyrnills Colony Company
Lands. 1'8_. PG_
P.l~l Pcrmanen[ Reference
Monumen[
pc, P. PellTklnent Comrol Pa.nl
ll'D Proponioned Section
Ureal-Gown
1. No underqround installations or' Il1prov...nt.
hay. been lac.ted except as noted.
2. No Ins~rullent.. of record reflectlnq ea.ements,
rlqhts of way,' and/or ownership were furnished
this surveyor except as shown.
J. This survey wa. prepared without the benefit
of a title sefrch.
LOr /8
)..""'
I\l~
" ~
" 0
":"-.." ~
{ Q ~
'--~~
:--.' .(:,
~ ~
~
LOrl7
~.
<"",,-
-S-o .
" ~
1\'l'I"
.11
r'l--v
Y' 20
t: Fred lJeue! and Assoc2ales, Inc.
ZephyrhlUa St. P~.nWurg
Cerlilicale of aulhorizalion number LB 107
'n1e property desc:r1bed hereon was sUIVeyed wJdc1" my direction
anj supervisia1, the sket.ch hereon is a I t..nJe and accurate
representation of the sarna and this sUIVey .""ts the /'Unimuon
Technical Standards set forth by the Floc idiJ 1Joard of Pro-
tess1mal Land SUrveyorS 1n Olapter 61G17-6 Florida Adninis-
tntive O:xle pursuant to Sec:t1oo 472.027, Florida Statutes,
JO/{M H. DENf/v10N$, JR, /? S.M.
~r.o'\
OWlY. tlY: ..~"'-._ Ckd. Ivy:
FORM 600A-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name:
Address:
City, State:
Owner:
Climate Zone:
Zirbel Addition
5430 18th street
Zephyrhills, FL 33542-
Sean & Heather Zirbel
Central
Builder:
Permitting Office:
Permit Number:
Jurisdiction Number:
1. New construction or existing
2. Single family or multi-family
3. Number of units, ifmulti-family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear glass, default U-factor
b. Default tint
c. Labeled U or SHGC
8. Floor types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Frame, Wood, Exterior
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Garage
b. N/A
Single Pane
0.0 ft'
0.0 ft2
0.0 ft2
Addition
Single family
1
2
No
1002.54 ft2
Double Pane
0.0 ft'
81.0 ft,
0.0 ft2
12. Cooling systems
a. Central Unit
Cap: 24.0 kBtuilrr
SEER: 11.00
h. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 24.0 kBtulhr
HSPF: 7.50
R=O.O, 151.0(p) ft
R=13.0, 1208.0 ft2
R=30.0, 1807.9 ft2
Sup. R=6.0, 250.0 ft
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 20.0 gallons
EF: 0.97
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HV AC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fan,
PT-Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.08
Total as-built points: 14403
Total base points: 15521
PASS
I hereby certify that the plans and specifications covered
by this calculation are in compliance with '7
Energy Code. .
PREPAREDBY~~
DATE: ;) ~ Iq. 0,-/ --
I hereby certify that this building, as designed, is in
compliance with the Florida Energy Code.
OWNE~AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING
DATE:
I=n..rn\lr.:.."n<>lS\ {\I..r"inn' 1=1 Rf'PR \/':1 ':In\
FORM 600A-2001
SUMMER CALCULATIONS
Residential Whole Buitdtng Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points
.18 1002.5 25.78 4652.2 Double, Tint N 8.0 5.5 16.2 20.63 0.67 225.0
Double, Tint W 1.0 7.5 16.2 40.60 0.99 648.6
Double, Tint W 1.0 13.5 16.2 40.60 1.00 654.6
Double, Tint E 1.0 16.0 16.2 45.16 1.00 728.5
Double, Tint E 1.0 12.0 16.2 45.16 1.00 727.6
As-Built Total: 81.0 2984.2
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.70 2053.6
Exterior 1208.0 1.90 2295.2
Base Total: 1208.0 2295.2 As-Built Total: 1208.0 2053.6
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 4.80 201.6
Exterior 42.0 4.80 201.6
Base Total: 42.0 201.6 As-Built Total: 42.0 201.6
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 1002.5 2.13 2135.4 Under Attic 30.0 1807.9 2.13 X 1.00 3850.8
Base Total: 1002.6 2136.4 As-Built Total: 1807.9 3860.8
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 151.0(p) -31.8 -4801.8 Slab-On-Grade Edge Insulation 0.0 151.0(p -31.90 -4816.9
Raised 0.0 0.00 0.0
Base Total: -4801.8 As-Built Total: 161.0 -4816.9
INFIL TRA TION Area X BSPM = Points Area X SPM = Points
1002.5 14.31 14346.3 1002.5 14.31 14346.3
~nOr"\I~~llnotli\ nr:4 ~nrrn RnnA_?M1
J:nQr"\I~~lInCllti'\ll=loQDC(~'?tY\1 1='1 ~f":PR '\~ ~
FORM600A-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
Summer Base Points: 18828.9 Summer As-Built Points: 18619.7
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(OM x OSM x AHU)
18619.7 1.000 (1.087 x 1.150 x 1.(0) 0.310 1.000 7215.4
18828.9 0.4266 8032.4 18619.7 1.00 1.250 0.310 1.000 7215.4
J:nort"l\~~II"'oTM n('/i. 1:",""" ~A_?I'Vl1
J:nArn\l~~lInclll'\/J:I~"'J:ctl?l'Vl1 1:1 "'''PR \A ~
FORM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point
.18 1002.5 5.86 1057.5 Double, Tint N 8.0 5.5 16.2 11.29 0.99 180.3
Double, Tint W 1.0 7.5 16.2 10.07 1.00 163.0
Double, Tint W 1.0 13.5 16.2 10.07 1.00 162.9
Double, Tint E 1.0 16.0 16.2 9.46 1.00 153.5
Double, Tint E 1.0 12.0 16.2 9.46 1.00 153.6
As-Built Total: 81.0 813.4
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.80 2174.4
Exterior 1208.0 2.00 2416.0
Base Total: 1208.0 2416.0 As-Built Total: 1208.0 2174.4
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 5.10 214.2
Exterior 42.0 5.10 214.2
Base Total: 42.0 214.2 As-Built Total: 42.0 214.2
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 1002.5 0.64 641.6 Under Attic 30.0 1807.9 0.64 X 1.00 1157.0
Base Total: 1002.5 641.6 As-Built Total: 1807.9 1157.0
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 151.O(p) -1.9 -286.9 Slab-On-Grade Edge Insulation 0.0 151.0(p 2.50 3n.5
Raised 0.0 0.00 0.0
Base Total: -286.9 As-Built Total: 151.0 377.6
INFIL TRA TION Area X BWPM = Points Area X WPM = Points
1002.5 -0.28 -280.7 1002.5 -0.28 -280.7
I=nArn\~QII"otR\ n,.. 6. I:'nrrn RnnA_?tV\1
I=nCllr"'\I~o::IllnGtS"l/-=I'l:Ig-=c::.1?t'V'\1 ~I J)r:PR \A. ~
FORM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
Winter Base Points: 3761.7 Winter As-Built Points: 4455.9
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(OM x OSM x AHU)
4455.9 1.000 (1.078 x 1.160 x 1.00) 0.455 1.000 2535.6
3761.7 0.6274 2360.1 4455.9 1.00 1.250 0.455 1.000 2535.6
I:nArl'l\~~II"a TM nr- A ~n""" RtYl6_?t'V'l1
I:n,c,rn\l~~llnAl1i'lJt=I'l:lII=)I:c:.'?M1 ~I J:)('PR,~ ~
FORM .600A-2001
.'WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2564.00 5128.0 20.0 0.97 2 1.00 2326.10 1.00 4652.2
As-Built Total: 4652.2
CODE COMPLIANCE STATUS
BASE AS-BUlL T
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points Points Points Points Points Points
8032 2360 5128 15521 7215 2536 4652 14403
I
PASS
I
I=nArl"l\tn!l:lllnQTM nr:A ~nrrn RIYlA_?M1
~nAr"\J~~llnGtfi'\/~kilj:)S:~1')M1 1=1 I:)("DR \~ ~
FORM 600A-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
PERMIT #:
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmlsa.ft. window area' .5 cfmlsa.ft. door area.
Exterior & Adjacent Walls 606.1 .ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sale or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & toplbottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the too olate.
Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the oerimeter. oenetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the oerimeter at oenetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
sealed box with 1/'2:' clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned soace tested.
Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavitY between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES fmust be met or exceeded bv all residences.l
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with effICiency requirements in Table 6-12. Switch or clearly marked circuit
breaker (electric) or cutoff (aas) must be DrovicJecl. External or built-in heat traD reauired.
Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). NOlKXlmmercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiencv of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG.
Air Distri>ution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls 607.1 Seoarate readilY accessible manual or automatic thermostat for each sYStem.
Insulation 604.1 , 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
I:'nOrt"l\.ln~111"'lQ 1M n,... A I:'nnn RtYl4._ ')(V'\1
I:'nCllr""/~~llnlClt&\/a::I'2I=)i=~1?tV\1 ~J ~""CR \A ~
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3
The higher the score, the more efficient the home.
Sean & Heather Zirbel, 5430 18th street, Zephyrhills, FL, 33542-
1. New construction or existing
2. Single family or multi-family
3. Number of units, if multi-family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SHGC - single pane
d. Tint/other SHGC - double pane
8. Floor types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
9 . Wall types
a. Frame, Wood, Exterior
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Garage
b. N/A
Single Pane
0.0 ft2
0.0 ft2
0.0 ft2
Addition
Single family
1
2
No
1002.54 ft2
Double Pane
0.0 ft2
81.0 ft2
0.0 ft2
12. Cooling systems
a. Central Unit
Cap: 24.0 kBtulhr
SEER: 11.00
R=O.O, I 51.0(p) ft
R=13.0, 1208.0 ft2
R=30.0, 1807.9 ft2
Sup. R=6.0, 250.0 ft
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 24.0 kBtulhr
HSPF: 7.50
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 20.0 gallons
EF: 0.97
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HV AC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86for a US EPA/DOE EnergyStJ~ designation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contactthe Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site atwww.fsec.ucfedufor
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 850/487-1824.
EnergyGauge@ (Version: FLRCPB v3.30)
Residential System Sizing Calculation
Summary
Project Title:
Zirbel Addition
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
Code Only
Professional Version
Climate: Central
Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M)
Humidit data: Interior RH 50% Outdoor wet bulb 6 Humidit difference 44 r.
Winter design temperature 38 F Summer design temperature
Winter setpoint 70 F Summer setpoint
Winter tern erature difference 32 F Summer tern rature difference
Total heatin load calculation 14603 Btuh Total coolin load calculation
Submitted heating capacity % of calc Btuh Submitted cooling capacity
Total (Electric Heat Pump) 164.4 24000 Sensible (SHR = 0.5)
Heat Pump + Auxiliary(O.OkW) Latent
Total Electric Heat Pum
93 F
75 F
18 F
13476 Btuh
% of calc Btuh
111 .1 12000
448.9 12000
WINTER CALCULATIONS
Winter Heatin Load
Load com nent
Window total
Wall total
Door total
Ceiling total
Floor total
Infiltration
Subtotal
Duct loss
TOTAL HEAT LOSS
81 sqft
1208 sqft
42 sqft
1808 sqft
151 ft
67 cfm
Load
1878
3141
632
1989
3911
2357
13907
695
14603
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Doors(4%)
SUMMER CALCULATIONS
Summer Coolina Load (for 1003 soft
Load comDonent Load
Window total 81 sqft 1166 Btuh
Wall total 1208 sqft 2102 Btuh
Door total 42 sqft 426 Btuh
Ceiling total 1808 sqft 2567 Btuh
Floor total 0 Btuh
Infiltration 59 cfm 1160 Btuh
Internal gain 2400 Btuh
Subtotal(sensible) 9821 Btuh
Duct gain 982 Btuh
Totall sensible gain 10803 Btuh
Latenl gain(infiltration) 1753 Btuh
Latenl gain(internal) 920 Btuh
Totali latent gain 2673 Btuh
TOTAL HEAT GAIN 13476 Btuh
Int.Gain(16%)
Infil.(9%)
EnergyGaugecfi> System Sizing..
PREPARED BY:
DATE: ::2.
EneravGauae<R> FLRCPB v3.30
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
System Sizing Calculations - Winter
Residential Load - Component Details
Project Title:
Zirbel Addition
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F
2/18/04
Window PaneslSHGC/Frame/U Orientation Area X HTM= Load
1 2, Tint, Metal, DEF E 16.2 23.2 376 Btuh
2 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh
3 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh
4 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh
5 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh
Window Total 81 1878 Btuh
Walls Type R-Value Area X HTM= Load
1 Frame - Exterior 13.0 1208 2.6 3141 Btuh
Wall Total 1208 3141 Btuh
Doors Type Area X HTM= Load
1 Insulated - Exter 42 15.0 632 Btuh
Door Total 42 632Btuh
Ceilings Type R-Value Area X HTM= Load
1 Under Attic 30.0 1808 1.1 1989 Btuh
Ceilina Total 1808 1989Btuh
Floors Type R-Value Size X HTM= Load
1 Slab-On-Grade Edge Insul 0 151.0 ft(p) 25.9 3911 Btuh
Floor Total 151 3911 Btuh
Infiltration Type ACHX Building Volume CFM= Load
Natural 0.40 10025(sqft) 67 2357 Btuh
Mechanical 0 o Btuh
Infiltration Total 67 2357 Btuh
Subtotal 13907 Btuh
Totals for Heating Duct Loss(using duct multiplier of 0.05 695 Btuh
Total Btuh Loss 14603 Btuh
Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint)
(Frame types - metal, wood or insulated metal)
(U - Window U-Factor or 'OEP for default)
(HTM - ManualJ Heat Transfer Multiplier)
Key: Floor size (perimeter(p) for s1ab-on-grade or area for all other floor types )
EneravGauae@ FLRCPB v3.30
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
System Sizing Calculations - Summer
Residential Load - Component Details
Project Title:
Zirbel Addition
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults) Summer Temperature Difference: 18.0 F
2/18/04
Type Overhang Window Area(sqfl) HTM Load
Window PaneslSHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded
1 2, Tint, DEF, B, N E 8 5.5 16.2 16.2 0.0 12 35 194 Btuh
2 2, Tint, DEF, B, N N 1 7.5 16.2 0.0 16.2 12 12 194 Btuh
3 2, Tint, DEF, B, N N 1 13.5 16.2 0.0 16.2 12 12 194 Btuh
4 2, Tint, DEF, B, N S 1 16 16.2 0.0 16.2 12 18 291 Btuh
5 2, Tint, DEF, B, N S 1 12 16.2 0.0 16.2 12 18 291 Btuh
Window Total 81 1166 Btuh
Walls Type R-Value Area HTM Load
1 Frame - Exterior 13.0 1208.0 1.7 2102 Btuh
Wall Total 1208.0 2102 Btuh
Doors Type Area HTM Load
1 Insulated - Exter 42.0 10.1 426 Btuh
Door Total 42.0 426 Btuh
Ceilings Type/Color R-Value Area HTM Load
1 Under Attic/Dark 30.0 1807.9 1.4 2567 Btuh
Ceilino Total 1807.9 2567 Btuh
Floors Type R-Value Size HTM Load
1 Slab-On-Grade Edge Insulation 0.0 151.0 ft(p) 0.0 0 Btuh
Floor Total 151.0 0 Btuh
Infiltration Type ACH Volume CFM= Load
Natural 0.35 10025 58.6 1160 Btuh
Mechanical 0 o Btuh
Infiltration Total 59 1160 Btuh
Occupants
4
Btuh/occupant
X 300 +
Appliance
1200
Load
2400 Btuh
Subtotal 9821 Btuh
Duct gain(using duct multiplier of 0.10) 982 Btuh
Total sensible gain 10803 Btuh
Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 1753 Btuh
Latent occupant gain (4 people @ 230 Btuh per person) 920 Btuh
Latent other gain 0 Btuh
TOTAL GAIN 13476 Btuh
Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint)
(U - Window U-Factor or 'DEF' for default)
(InSh - Interior shading device: none(N), BlindslDaperies(B) or Roller Shades(R))
(ExSh - Exterior shading device: none(N) or numerical value)
(Omt - compass orientation)
EnerovGauae<ll) FLRCPB v3.30
FORM 600A-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name:
Address:
City, State:
Owner:
Climate Zone:
Zirbel Addition
5430 18th street
Zephyrhills, FL 33542-
Sean & Heather Zirbel
Central
Builder:
Pennitting Office:
Permit Number:
Jurisdiction Number:
1. New construction or existing
2. Single family or multi-family
3. Number of units, ifmulti-family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (Ii>)
7. Glass area & type
a. Clear glass, detault U-factor
b. Default tint
c. Labeled U or SHGC
8. Floor types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Frame, Wood, Exterior
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Garage
b. N/A
Sing.lePane
0.0 ftZ
0.0 ft2
0.0 ftZ
Addition
SinglelamiIy
I
2
No
1002.54 ft2
Double Pane
0.0 ftZ
81.0 ft2
0.0 ft2
R=O.O, 151.0(p) ft
R=13.0. 1208.0 ft2
R=300. 1807.9 ft2
Sup. R=6.0. 250.0 ft
I 12. Cooling systems
a. Central Unit
Cap: 24.0 kBtulhr
SEER: 11.00
b. N/A
. c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 24.0 kBtu!hr
HSPF: 7.50
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 20.0 gallons
EF: 0.97
b. N/A
c. Conservation credits
(HR-Heat recovery. Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan. CV-Cross ventilation.
HF-Whole house Ian.
PT-Programmable Thermostat
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.08
Total as-built points: 14403
Total base points: 15521
PASS
I hereby certify that the plans and specifications covered
by this calculation are in.. compo Iiance with the FlofYrida
Energy Code. . , __ 4
PREPAREDBY~~~~
DATE: :)./q.o~ --
I hereby certify that this building, as designed, is in
compliance with the Florida Energy Code.
OWNER/AGENT:
DATE:
~n'>r"\I~"""cIli\ (\/or.,,,,n. J:'I RrOl:l ,,':I ':In\
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFI
DATE:
FORM 600A-2001
SUMMER CALCULATIONS
Residential Whole BuHding Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points
.18 1002.5 25.78 4652.2 Double, Tint N 8.0 5.5 16.2 20.63 0.67 225.0
. .
Double, Tint W 1.0 7.5 16.2 40.60 0.99 648.6
Double, Tint W 1.0 13.5 16.2 40.60 1.00 654.6
Double, Tint E 1.0 16.0 16.2 45.16 1.00 728.5
Double, Tint E 1.0 12.0 16.2 45.16 1.00 727.6
As-Suilt Total: 81.0 2984.2
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.70 2053.6
Exterior 1208.0 1.90 2295.2
Base Total: 1208.0 2295.2 As-Suilt Total: 1208.0 2053.6
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 4.80 201.6
Exterior 42.0 4.80 201.6
Base Total: 42.C 201.6 As-Built Total: 42.0 201.6
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 1002.5 2.13 2135.4 Under Attic 30.0 1807.9 2.13 X 100 3850.8
Base Total: 1002.5 2135.4 As-Suilt Total: 1807.9 3850.8
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 1510(p) -318 -4801.8 Slab-On-Grade Edge Insulation 0.0 151.0(p -31.90 -4816.9
Raised 0.0 0.00 0.0
Base Total: -4801.8 As-Suilt Total: 151.0 -4816.9
INFILTRATION Area X BSPM = Points Area X SPM = Points
1002.5 14.31 14346.3 1002.5 14.31 14346.3
~nAr""~~II"AI1ft nr ~ J:nrrn ~nA_ ..,nn1
!:"Ar""~':::llIIf"uw1i"j:'I~D-=~'..,nn1 ~I Q("C!:l \1'11.n
FORM 600A-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
Summer Base Points: 18828.9 Summer As-Built Points: 18619.7
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(OM x OSM x AHU)
18619.7 ,1.000 (1.087 x 1.150 x 1.00) 0.310 1.000 7215.4
18828.9 0.4266 8032.4 18619.7 1.00 1.250 0.310 1.000 7215.4
t:n,Qr"'''(-::~II'''AfM n,...~ ~nrn"t '::(YHL,)1Y\1
!::ru:lor"'~21Inalii\/I:'I~I;t-=c:::'..,nn1 1:'1 P("'OI:): \/~ ~n
FORM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point
.18 1002.5 5.86 1057.5 Double, Tint N 8.0 5.5 16.2 11.29 0.99 180.3
Double, Tint W 1.0 7.5 16.2 10.07 1.00 163.0
Double, Tint W 1.0 13.5 162 10.07 1.00 162.9
.
Double, Tint E 1.0 16.0 16.2 9.46 1.00 153.5
Double, Tint E 1.0 12.0 16.2 9.46 1.00 153.6
As-Suilt Total: 81.0 813.4
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.80 2174.4
Exterior 1208.0 2.00 2416.0
Base Total: 1208.0 2416.0 As-Suilt Total: 1208.0 2174.4
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Extenor Insulated 42.0 5.10 214.2
Exterior 42.0 5.10 214.2
Base Total: 42.0 - 214.2 As-Suilt Total: 42.0 214.2
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 1002.5 0.64 641.6 Under Attic 30.0 18079 0.64 X 1.00 1157.0
Base Total: 1002.5 641.6 As-Built Total: 1807.9 1157.0
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 1S1.0(p) -1.9 -286.9 Slab-On-Grade Edge Insulation 0.0 151.0(p 2.50 3n.S
Raised 0.0 0.00 0.0
Base Total: -286.9 As..auilt Total: 151.0 3n.5
INFIL TRA TION Area X BWPM = Points Area X WPM = Points
1002.5 -0.28 -280.7 1002.5 -0.28 -280.7
!:"Orn\,r.:~II"afIi'\ nf"A 1:''''........ ~4_")('V11
!:"Ar"\I~~II,..GIIt1i'\/!:'I'2IQ-=~1">f"V\1 1:'1 I;t("OR \I~ ~
FORM 600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
Winter Base Points: 3761.7 Winter As-Built Points: 4455.9
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
4455 9 1.000 (1.078 x 1.160 x 1.(0) 0.455 1.000 2535.6
3761.7 0.6274 2360.1 4455.9 1.00 1.250 0.455 1.000 2535.6
t::nQrrn,~:=aII"'QrM nr~ ~n,..,..., ~.6_-:f'V'\1
!::f""~I"'''\I~:aII"ai1i\I-=I~j:)~~'..,nn1 C'I orPR Ill. ':If'
FORM 600A-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
PERMIT #:
BASE AS-BUlL T
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2564.00 5128.0 20.0 0.97 2 1.00 2326.10 100 4652.2
As-Built- otal: 4652.2
CODE COMPLIANCE STATUS
BASE AS-BUlL T
Cooling + Heating + Hot Water = Tot~ ; Cooling + Heating + Hot Water = Total
Points Points Points Pair '5 Points Points Points Points
8032 2360 5128 155~ 1 7215 2536 4652 14403
u\SS
I
i=n.Qr"\lr::~II".aTM n,...~ ~,...."'" ~A_"M1
~"or""/~::IlI"otii\JC'I~g~~''''(VH ~I O('OQ u-:t ~n
FORM 600A-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
PERMIT #:
ADDRESS: 5430 18th street, Zephyrhills, FL, 33542-
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
6A-2 OTHER PRESCRIPTIVE MEASURES must b~ met or exceeded b all residences.
COMPONENTS SECTION REQUIREMENT:
Water Heaters 612.1 Comply with effic'. .ncy requirements in Table 6-12. Switch or cleanv marked circuit
breaker electric. r cutoff as must be rovided. External or bullt-,n heat tra r U1red.
Spas & heated p<ois must have covers (except solar heated). NOrKOmmercial pools
must have a pum' timer. Gas spa & pool heaters must have a minimum thermal
effiCiency of 78~
Water flow must e restricted to no more than 2.5 allons r minute at 80 PSIG.
All ducts, fittings -nechanical equipment and plenum chambers shait be mechanically
attacned, sealeo, ,1SUlated, and installed in accordance with the cmeria of Section 610.
Ducts in uncondlkmed attics: R-6 min. insulation.
Seoarate readily c!:~cessible manual or automatic thermostat for eacn stem.
Ceilings-Min. R- 'i Common walls-Frame R-11 or CBS R-3 both SiOes
Common ceiling <:. rloors R-11 .
COM NENTS
Exterior Windows & Doors
Exterior & Adjacent Walls
SECTION
i 606.1.ABC.1.1
i 606.1.ABC.1.2.1
I
Floors
1606.1.ABC.1.2.2
Ceilings
606.1.ABC.1.2.3
Recessed Lighting Fixtures
!606.1.ABC.1.2.4
Multi-sto Houses
Additional Infiltration reqts
606.1.ABC.1.2.5
606.1.ABC.1 .3
Swimming Pools & Spas
612.1
Shower heads
Air Distribution Systems
612.1
: 610.1
HVAC Controls
607.1
604.1, 602.1
Insulation
=I"'IQr"''''~-:lII'''QTM nrl\. i=nrn"l ~nnA_"f"\('\1
I REQUIREMENTS FOR EACH PRACTICE
! Maximum:.3 cff!1l .ft. window area. .5 cfml .ft. door area.
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
i EXCEPTION: Frame walls where a continuous infiltration barrier is Installed that extends
I
: from, and is sealed to the foundation to the to late.
I Penetrations/openings >1/8" sealed unless backed by truss or joint members.
: EXCEPTION: F 'ame tIoor$ where a continuous infiltration barrier's installed that is sealed
to the rimeter ::>enetrations and seams.
Between walls & ceilings; penetrations of ceiling plane of top floor. around shafts, chases,
soffits, chimneys. cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
, attic access. EYCEPTION: Frame ceilings where a continuous infiltration barrier is
, installed that is;ealed at the rimeter at netrations and seams.
Type IC rated With no penetrations, sealed; or Type IC or non-IC rated, Installed inside a
sealed box with 2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
I conditioned s ", tested.
Air barrier on r---,eter of floor cavi between floors.
Exhaust fans veil, ~ to outdoors, dampers; combustion space hearers comply with NFPA.
; have combustion.lr.
CHECK
CHECK
;:nar"\I~c:JII,.,Clliin/~I-=-g~C:::""'f'Vl1 1:'1 i::)rCR \/~ <n
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMA TED ENERGY PERFORMANCE SCORE* = 84.3
The higher the score. the more efficient the home.
Sean & Heather Zirbel, 5430 18th street, Zephyrhills, FL, 33542-
I. New construction or existing
2. Single fiunily or multi-fiunily
3. Number of units, if multi-tamily
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SHGC - single pane
d. Tint/other SHGC - double pane
8. Floor types
a. SlalrOn-Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Frame. Wood. E:-..'terior
b. N/A
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N;A
I I . Ducts
a. Sup: Vnc. Ret: Vnc. AH: Garage
b. N/A
Addition
Single fiunily
I
Single Pane
0.0 ft2
0.0 ft2
0.0 ft2
No
1002.54 ft2
Double Pane
0.0 ft2
81.0 ft2
0.0 ft2
12. Cooling systems
a. Central Unit
Cap: 24.0 kBtulhr
SEER: 11.00
R=O.O. 151.01p) ft
R=13.0. 1208.0 ft2
.R=30.0. 1807.9 ft2
Sup. R=DO. 250.0 ft
2
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 24.0 kBtulhr
HSPF: 7.50
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 20.0 gallons
EF: 0.97
b. N/A
c. Conservation credits
(HR-Heat recoveTV. Solar
DHP-Dedicated heat pump)
15. HV AC credits
(CF-Ceiling tan. CV-Cross ventiIauon..
!-IF-Whole house tan.
PT-Programmable Thermostat.
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
r certifY that this home has complied \\lIh [he Florida Energ' Efficiency Code For Building
Construction through the above energy sa\ing features whid, will be installed (or exceeded)
in this home before final inspection. Otherwi.se. :1 new EPL .'isplay Card will be completed
based on installed Code compliant tearures.
Builder Signature:
Address of New Home:
)ate:
.:::ity/FL Zip:
*NOTF;: The home's eSTImated energy performance score is on(v available through the FLtRES c'OI7WUler program.
This is 1'1!2! a Building Fnergy Raling. J\our score IS 80 or sreater (or 86 jor a (,5' EP. l.DOE Ener<::. ,,'toff deSignatIOn;,
,\lOUr home may qualifY/or energv ejJiClencv mortgage I EEA1) incentives if you obtain a FlOrida Ene",:,,:, Gauge Racing.
(.'antact the Aller~ Gauge Hotline at _;::.. t538-i ../92 or see the Energy (rauge web sile al www.l,~ec. :",.'.edu flJr
mfhrmation and (I list o(certijied Raters. ,C;-or inf()rmalion aboul l'1orllla's Energy EjJiciencv CJue i;'r Building ( 'on.wnlclion.
':ontact the Department olCommuml1'. Ufmrs af "5U.J87-182~.
EnergvGauge''w (Version: FLRCPB \3.30)
Residential System Sizing Calculation
Summary
Project Title:
Zirbel Addition
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
Code Only
Professional Version
Climate: Central
Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M)
Humidit data: Interior RH 50% Outdoor wet buib 76 Humidit difference 44 r.
Winter design temperature 38 F Summer design temperature
Winter setpoint 70 F Summer setpoint
Winter tem erature difference 32 F Summer tem erature difference
Total heatin load calculation 14603 Btuh Total coolin load calculation
Submitted heating capacity % of calc Btuh Submitted cooling capacity
Total (Electric Heat Pump) 164.4 24000 Sensible (SHR = 0.5)
Heat Pump + Auxiliary(O.OkW) Latent
Total Electric Heat Pum
Winter Heatin Load
Load com onent
Window total
Wall total
Door total
Ceiling total
Floor total
Infiltration
Subtotal
Duct loss
TOTAL HEAT LOSS
Summer Coolin Load
Load com onent
Window total
Wall total
Door total
Ceiling total
Floor total
Infiltration
Internal gain
Subtotal(sensible)
Duct gain
Toted sensible gain
Latent gain(infiltration)
Latent gain(internal)
Total latent gain
TOTAL HEAT GAIN
93 F
75 F
18 F
13476 Btuh
% of calc Btuh
111.1 12000
448.9 12000
. -WINTER CALCULATIONS
ft
Ducts(5%)
Load ~ ''-lindowst13%)
\ i ~',
81 sqft 1878 BtLh !nnl (16%) /'/ \,; """"_-.
\ I ' ~
I \ i ~\
1208 sqft 3141 Bttn / \ : ' . C~Ij;ncS -~7?)
/ \ I
42 sqft 632 BtLl .. ; I
,_______ \ i
1808 sqft 1989 BtL."1 :JoorS(4%I, ___-------]/.
I '. --------,
151 ft 3911 Btt '1 \
,
67 cfm 2357 BtLl "
J ,
13907 Btl.. fl I // '-'Valls(22%)
Floors(27%) "- "
695 BtLn, , ~-~~
14603 BtL!!J
81 sqft
1208 sqft
42 sqft
1808 sqft
59 cfm
SUMMER <;ALCULATIONS
ft
Load '~
~~~~ ::~~
426 Bh:n
2567 BtDn
o Btu h
1160 Btun
2400 Stuh
9821 Btuh
982 Stuh
10803 Btuh
1753 Btuh I
920 Stuh
2673 Btuh
13476 Btuh
EnerovGauoeOO FLRCPB v3 30
Latent ln1emal(1~~~.It"dOW'S19%)
'\ i '.
\,
(--~:~----- --
, ' '\
:'ll.l:'~lOfl0":':,) I"
Lilterrt rnfil (13%)....
/
l' ,..thn~<;l .~ -"':, 'I
" \
, ,
, W~IIS(lh",,*'
,
!
Ducts(7%) "'.i..
-,/
nlil (9%)
'onrs(3"hl
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
System Sizing Calculations - Winter
Residential Load - Component Details
Project Title:
Zirbel Addition
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F
2/18/04
Window Panes/SHGC/Frame/U Orientation Area X HTM= Load
1 2, Tint, Metal, DEF E 16.2 23.2 376 Btuh
2 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh
3 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh
4 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh
5 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh
Window Total 81 1878 Btuh
Walls Type R-Value Area X HTM= Load
1 Frame - Exterior 13.0 1208 2.6 3141 Btuh
Wall Total 1208 3141 Btuh
Doors Type Area X HTM= L~ad
1 Insulated - Exter 42 15.0 632 Btuh
Door Total 42 632Btuh
Ceilings Type R-Value Area X HTM= Load
1 Under Attic 30.0 1808 1.1 1989 Btuh
Ceilina Total 1808 1989Btuh
Floors Type R- Value Size X HTM= Load
1 Slab-On-Grade Edge Insul 0 151.0 ft(p) 25.9 3911 Btuh
Floor Total 151 3911 Btuh
Infiltration Type ACHX Building Volume CFM= Load
Natural 0.40 10025(sqft) 67 2357 Btuh
Mechanical 0 o Btuh
Infiltration Total 67 2357 Btuh
Subtotal 13907 Btuh
Totals for Heating Duct Loss(using duct multiplier of 0.05 695 Btuh
Total Btuh Loss 14603 Btuh
Key: Window types (SHGC - Shading coeffiCIent of glass as SHGC numerical value or as clear or tint)
(Frame types - metal. wood or insulated metal)
(U - Window U-Factor or 'DEF' for default)
(HTM - ManualJ Heat Transfer Multiplier)
Key: Floor size (perimeter(p) for slab-on-grade or area for all other floor types)
EneravGauoeOO FLRCPA v3 30
Sean & Heather Zirbel
5430 18th street
Zephyrhills, FL 33542-
System Sizing Calculations - Summer
Residential Load - Component Details
Project Title:
Zirbel Addition
Code Only
Professional Version
Climate: Central
Reference City: Orlando (Defaults)
Summer Temperature Difference: 18.0 F
2/18/04
Type Overhang Window Area(sqft) HTM Load
Window PanesJSHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded
1 2, Tint, DEF. S, N E 8 5.5 16.2 162 0.0 12 35 194 Btuh
2 2. Tint. DEF. S, N N 1 7.5 '6.2 0.0 16.2 12 12 194 Btuh
3 2, Tint, DEF, S, N N 1 13.5 '6.2 0.0 16.2 12 12 194 Btuh
4 2, Tint, DEF. S, N S 1 16 '6.2 0.0 16.2 12 18 291 Btuh
5 2, Tint, DEF, S, N S 1 12 16.2 0.0 16.2 12 18 291 Btuh
Window Total 81 1166 Btuh
Walls Type R-Value Area HTM Load
1 Frame - Exterior 13.0 1208.0 1.7 2102 Btuh
Wall Total 1208.0 2102 Btuh
Doors Type Area HTM Load
1 Insulated - Exler 42.0 10.1 426 3tuh
Door Total 42.0 426 Btuh
Ceilings Type/Color R-Value Area HTM Load
1 Under A!tici Dark 30.0 1807.9 1.4 2567 3tuh
Ceilina Total 1807.9 2567 Btuh
Floors Type R-Value Size HTM Load
1 Slab-On-Grade Edge Insulation 0.0 151.0/t(p) 00 J Btuh
Floor Total 151.0 . 0 Btuh
.
Infiltration Type ACH Volume CFM= Load
Natural 0.35 10025 58.6 1160 3tuh
Mechanical 0 ] 8tuh
Infiltration Total 59 1160 Btuh
Occupants
4
Btuh/occupant
X 300 +
Appliance
1200
Load
2400 Btuh
Subtotal 9821 Btuh
Duct gain(using duct multiplier of 0.10) 982 Btuh
Total sensible gain 10803 Btuh
Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 1753 Btuh
Latent occupant gain (4 people @ 230 Btuh per person) 920 Btuh
Latent other gain 0 Btuh
TOTAL GAIN 13476 Btuh
Key: Window types (SHGC - Shading coefficient of glass as SHGC numencal value or as clear or tint)
,U - Window U-Factor or 'DEF' for defauit)
i.lnSh - ,nterior shading device: none(N), BlindslDaperies(B) or Roller Shades(R\)
I ExSh . Exterior shading device: none(N) or numerical value)
(Omt - ~ompass onentation)
EnernvGauaeOO FLRCPB v3 30