Loading...
HomeMy WebLinkAbout04-2784 ~ CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 2784 Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 2784 ADDITION/ALTERATION 434-ADD/AL T RESIDENTIAL SINGLE FAMILY RESIDENTIAL Address: 5430 18TH ST ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 25,000.00 3/03/2004 869.32 869.32 3/03/2004 I Phone: ADDING GARAGE ANl= FAMILY ROOM AND BEDROOM Name: SEAN & HEATHER ZIRBEL Address: 5430 18TH ST ZEPHYRHILLS, FL. 33542 D U I I PRE-SLAB 01 I CONSTRUCTION POLE 2ND ROUGH PLUMB JfffDUCTS INSULATED LINTEL PRE-METER ! WATER . FINAL MECHANICAL FRAME MISC SEWER ' MISC INSULATION WALL lMISC I MISC. MISC. INSULATION CEILING MISC. MISC. MISC. DRIVEWAY.. .~ISC. . . I MISC. , FIRE DEPT. FINAL REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record-it notice of commencement may result in your paying twice for I improvements to your property. If you intend to obtain financing, consult with your lender or an attorney I before recording your notice of commencement." r.--- ----.. . Complete Plans, Specifications and Fee Must Accompany Application. _. All work shqU, be performed in accordance with City Codes and Ordinances ,~~ ~ -- --- NOOCCUPANCYBEFOREC.O. ~ . .. Ii ~_ CT SIG ~TURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER NOTICE OF COMMENCEMENT _. State of -.iJo ~I b A County of ?A?CO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel No. /I-';?/v-of/- OO/()- 11500-{)J76 5if.7() 18f-h 5T 2Ef?H~I2I-JJ U~ (Legal description of t e property and street address if available) 2. General Description of Improvement A6 /j} 7/~AJ -::. ~6~ / f/hsfr:=fi. f3-ecl1OJ~jif) I ~-' i) 1111111111111111I1111111111111111111111111111111111111111111 2004037437 /i:1o;d l/ If U(J/YJ I Owner Information: Name .5EAtJ ANi-::J J~ -rJ+F....A 2, J<BE. L Address oL/Eb IBM S T City&t'HY/<-rlJ LL5 State~L. 335t.j;). Rcpt: 761124 Rec: 6.00 DS: 0.00 IT. 0 00 03/03/04 ___~ Dpty Clerk JED PITTMANft PASCO COUNTY CLERK 03/03/04 1~:05am 1 of 1 OR BK 5749 PG 1113 City ,state Interest in Property: 0' Name of Fee Simple Titleholder: /V'IA (If other than owner) , Address 4. Contractor: Name 5EI ~ Address 0" i? () /8' ..J. h .sT"' City C<fh. vthi JI .5 / State f! 5, Surety: Name Address City State Amount of Bond: $ 6. Lender: Name Address City State 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) (7), Florida Statutes: Name Address City State 8. In addition to himself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. 9. Expiration date of Notice of Commencement (the expiration date is 1 year from the date of recording unless a d[:~r~ntdatei: speCIfie/~> f SignatureofOwner:?<' /~&, ~ ' Sworn to and subscribed before me this 0~/ day of '-1Y\oJ\..Q..~ , 20 Cy--{ . '- Notary Publi ' ....~r;.y.'}~ amY WILLIAMS t.~' \;, MY COMMISSION # DO 058015 - . :- '.. My Commission Expires: PC93053048/ A ~ 2184 City of Zephyrhills Building Department 5335 Eighth Street Zephyrhills, FL 33540 April 27, 2005 Dear Sirs and/or Madams, It has come to our attention that we have missed the deadline for our inspection that would have included framing, electrical, mechanical, and plumbing. I apologize for the inconvenience this may cause the City Building Inspectors. I am a full time hardworking husband and father of two. I have been working on this 1800 square foot addition on my time off. Time off is hard to find; as I am sure you are all well aware of, therefore this has been a weekend endeavor for the past year. My wife and I try very hard to complete things on time, but we would appreciate your understanding in our inability to make the deadline. It is our hopes that you will be able to extend the deadline; so as we can complete what I know will be, not only an improvement for my family but our Sean Zirbel ~vP Gf' I d' e.{ I ~)6 \)1M" qa ..~/ IP (lJvJ1 neighborhood as well. Zy 5430 Eighteenth Street Zephyrhills, FL 33540 (813) 788-0185 CITY OF ZEPHYRHILLS PERMIT APPLICATION BUILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-Q021 DATE RECEIVED PHONE CONTACT FOR PERMITTING OWNER'S NAME ~ Zlte.8E-L JOB ADDRESS rH sr LEGA.L DESCRIP. / ~ I ? -f- /9 BLOCK Iii} PARCEL ID # I/-~(P-dl- On/()-IJ./ 5'00- ()/''7() PHONE f3J 3-788- O/BS SUBDIVISION (OBTAIN FROM PROPER~X TAX NOTICE) WORK PROPSED: ONEW CONSTRUCTION OSIGN . ADDITION o MOVE OALTERATION D REPAIR D INSTALL o DEMOI,ISH PROPOSED USE :){SGL FAMILY DWELLING D COMMERCIAL DMULTI - FAMILY o INDUSTRIAL D# OF UNITS o SWIMMING POOL D MOBILE HOME D OTHER DESCRIpTION OF WORK D RESTAURANT & HEALTH DEPARTMENT APPROVAl, 1+6 tJ I III l- ~~ I1m/Lv,(!am .;- 8d~ / ~ I &B FOOTAGE I. 't) 7 ~ HEIGHT BUILDING SIZE SQUARE RESIDENTIAL: ATTACH rJl1 PLOT PLANS & (~SETS OF BUILDING PLANS & ('9;1/ SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REQUESTED E XI.5- //# b- AMP SERVICE jJc;{6 ~ FLORIDA POWER ~>~.\ I I / ./ W.R.E.C. ~ BUILDING }(ELECTRIC1\TJ $__c2r5' K VALUATION OF TOTAL CONSTRUCTION D 14 PLUMBING D MECHANICAL $ o GAS jZ(ROOFING 0 SPECIALTY VALUATION OF MECHANCIAL INSTALLATION D OTHER TYPE OF CONSTRUCTION: D BLOCK );( FRAME o STEEL D OTHER FINISHED FLOOR ELEVATIONS IS PRO.JECT IN FLOOD ZONE AHEAD YES M NO f:'l; ... ~'.,':if';,:.iJ - "-~~0_'._ ,:j;-,t"r;,:.," ;1;~2S tr> j,J r-.vf .t::::,.-/ ,- ;. t:OMPANY '-'C f- - 1lE1l7J-t&( /It Z/~BEL BUILDER SIGNATURE ELECTIlICIAN /, / ~. COM~;""Y SID? SIGNATURE I~ STATE CERT OR REGIST # OTHER ********************************************* PLUMBl!lR I( c.- COMPANY JEi I- SIGNATURE STATE CERT OR REGIST # ******************************************* COM~hNy 8Ei;:- SIGNATURE STATE CERT OR REGIST # ~~****************************************** \ , COMPANY fiEf;: SIGNATURE STATE CERT OR REGIST # A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed restrictions" which may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITtES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indica~ion that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", T cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR' S/OWNER' S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone "A" or "A,ete.", it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter reqlliring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized bY such permit is commenced vd thi n six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT". SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _ day of by acknowledged , 20_ STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _day of by acknowledged , 20 (name of person acknowledged) Dwho is personally known to me, or (name of person acknowledged) [lho is personally known to me, or of identification) take an oath. Dwho has produced (type of identification) and who Ddid OEd not take an oath Dwho has produced (type and wrioD did Ddid not Signature of person taking acknowledgement Signature of person taking acknowledgment Name typed, printed or stamped Name typed, printed or stamped Heather M. Zirbel 5430 - 18th St. SQ. FEET PRICE MAIN OR LIVING: 1,807 $ 50.00 OTHER AREA UNDER ROOF: $ 25.00 OTHER: - $ - VALUATION $ 90,350.00 FEE SHEET $ 444.00 ADDRESS $ - DRIVEWAY $ - BUILDING: $ 666.00 CREDIT: $ - BUILDING LESS CREDIT: $ 666.00 ELECTRICAL: $ 65.75 PLUMBING: $ 59.50 MECHANICAL: $ 60.00 RADON: $ 18.07 TOTAL $ 869.32 SEWER: $ - WATER: $ - IRRIGATION: $ - TOTAL: $ - WATER METER:I $ IRRIGATION METER $ SUB-TOTAL $ 869.32 I SIF'S:I $ 97.5% $ 2.5% $ T IF'S :1 $ 99% $ 1% $ TOTAL: $ 869.32 I C. ,RED DEUEL & ASSOCIATES, INC. 5151 GALL BLVD. ZEPHYRHILLS, ,LORIDA 33541 PHONE: (613) 762-6717 ,AX: (613) 762-5426 /Z '/z "1 (I 0 1-13' (.,0.00' I . O' t .. v ~!.;;.'rt ,:;;Tt-J AVE' 10/." C02 BLOCK ,41. ^' W COINF~ 6l0cK 1<15 30' "" ~ '- "' ~ I:l ~ ~ ~ C o l::l ~ ~ 20 k~ ~ \tj , l ~I).. II)~ ~ ~ :. ~ () ~'9 AI 2Ul IJo.o' laJ ., ""' t;::"'L. S~A. to .,; ... ;-.. ~ l\:) ~ .,II'~ (p ~ 01';' ~,P. ~. /-I' /. (J. Q' \: " \;\~ . ?',!l'.r\;':o-. ~. '" <t /9.7' ~ ~ ~~ '10 /40.00' e~I'M) 20' A ~~E"" (VA//_PROVED) (40 00 -I 30' \.~. ~.\\\ I' ~o LEGAL DESCRIPTION Lots 17, 18 and 19, Block 145, CITY OF ZEPHYRHILLS, as recorded in Plat Book 1, Page 54, Public Records of Pasco CountYi Florida. FOR: SEAN ZIRBEL SURVEY DATE: . OG~ 9, 1998 BOUNDARY SURVEY ORDER #12323-ZH k0 \ L ~~' ..:./ i ,;,1')", 1\1)00" "Il fll ~. II vL'-, II, Ivvr. c-\V ..J.,I,(I'I\.7.C-1 C. ~ Pasco County, Florida '~ W .' ';'~~~. '\ '- P, . ""/" .......",- V s Scale: 1" =30' " -""~ o 15' 30 ~o (/<tNl) LOII9 1;1' 'I.' :" .3 ~ gO '- NOT VALID UNLESS EMBOSSED WlTI-l A SEAL THIS STAMP IS RED Ce/l.T/r/EO '/0'- . SUA/c.o.-u-r SCHOOL FG'.oER-4L CREDIT L/N/ON SC/IVSTA7"E TITLE r/Rsr -"f/l4c,cz/C"lN T/TL.E SGAN Z/R8EL ~~'/4 - Not valid without the signature and the original raised seal of a Florida licensed surveyor arxl mapper. SURVEYORS 1l0'l'ES: LeQend IR) Pe,1.egal Descnptlon .' p..t ICJ Calculdled 1~11 Field MedsurecJ FI. R. Found Iron Rod FI.P Found Iron P,pe rCM. Found Concrete Monument CI..F Cha,n Unk Fence \II.F. Wlte Fence \VD.F. Wooocn Fence PI' Power Pole a.H.1.. Overhead Une ,"O.B. POInt of Ileg,nn,ng C.f' Edge of Pavement f~. I.. POint on Une HR. Set liZ' 'ran Rod Capped with LB# I 07 r.O.B. Top a/Bank TO S. Taeo/Slope Il/W.l/ R'ghrofWay ro. C 1'0,01 of Commenccm(.nl ZHCCL Zephyrnills Colony Company Lands. 1'8_. PG_ P.l~l Pcrmanen[ Reference Monumen[ pc, P. PellTklnent Comrol Pa.nl ll'D Proponioned Section Ureal-Gown 1. No underqround installations or' Il1prov...nt. hay. been lac.ted except as noted. 2. No Ins~rullent.. of record reflectlnq ea.ements, rlqhts of way,' and/or ownership were furnished this surveyor except as shown. J. This survey wa. prepared without the benefit of a title sefrch. LOr /8 )..""' I\l~ " ~ " 0 ":"-.." ~ { Q ~ '--~~ :--.' .(:, ~ ~ ~ LOrl7 ~. <"",,- -S-o . " ~ 1\'l'I" .11 r'l--v Y' 20 t: Fred lJeue! and Assoc2ales, Inc. ZephyrhlUa St. P~.nWurg Cerlilicale of aulhorizalion number LB 107 'n1e property desc:r1bed hereon was sUIVeyed wJdc1" my direction anj supervisia1, the sket.ch hereon is a I t..nJe and accurate representation of the sarna and this sUIVey .""ts the /'Unimuon Technical Standards set forth by the Floc idiJ 1Joard of Pro- tess1mal Land SUrveyorS 1n Olapter 61G17-6 Florida Adninis- tntive O:xle pursuant to Sec:t1oo 472.027, Florida Statutes, JO/{M H. DENf/v10N$, JR, /? S.M. ~r.o'\ OWlY. tlY: ..~"'-._ Ckd. Ivy: FORM 600A-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Address: City, State: Owner: Climate Zone: Zirbel Addition 5430 18th street Zephyrhills, FL 33542- Sean & Heather Zirbel Central Builder: Permitting Office: Permit Number: Jurisdiction Number: 1. New construction or existing 2. Single family or multi-family 3. Number of units, ifmulti-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear glass, default U-factor b. Default tint c. Labeled U or SHGC 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Garage b. N/A Single Pane 0.0 ft' 0.0 ft2 0.0 ft2 Addition Single family 1 2 No 1002.54 ft2 Double Pane 0.0 ft' 81.0 ft, 0.0 ft2 12. Cooling systems a. Central Unit Cap: 24.0 kBtuilrr SEER: 11.00 h. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 24.0 kBtulhr HSPF: 7.50 R=O.O, 151.0(p) ft R=13.0, 1208.0 ft2 R=30.0, 1807.9 ft2 Sup. R=6.0, 250.0 ft b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 20.0 gallons EF: 0.97 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT-Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.08 Total as-built points: 14403 Total base points: 15521 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with '7 Energy Code. . PREPAREDBY~~ DATE: ;) ~ Iq. 0,-/ -- I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNE~AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING DATE: I=n..rn\lr.:.."n<>lS\ {\I..r"inn' 1=1 Rf'PR \/':1 ':In\ FORM 600A-2001 SUMMER CALCULATIONS Residential Whole Buitdtng Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1002.5 25.78 4652.2 Double, Tint N 8.0 5.5 16.2 20.63 0.67 225.0 Double, Tint W 1.0 7.5 16.2 40.60 0.99 648.6 Double, Tint W 1.0 13.5 16.2 40.60 1.00 654.6 Double, Tint E 1.0 16.0 16.2 45.16 1.00 728.5 Double, Tint E 1.0 12.0 16.2 45.16 1.00 727.6 As-Built Total: 81.0 2984.2 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.70 2053.6 Exterior 1208.0 1.90 2295.2 Base Total: 1208.0 2295.2 As-Built Total: 1208.0 2053.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 4.80 201.6 Exterior 42.0 4.80 201.6 Base Total: 42.0 201.6 As-Built Total: 42.0 201.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1002.5 2.13 2135.4 Under Attic 30.0 1807.9 2.13 X 1.00 3850.8 Base Total: 1002.6 2136.4 As-Built Total: 1807.9 3860.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 151.0(p) -31.8 -4801.8 Slab-On-Grade Edge Insulation 0.0 151.0(p -31.90 -4816.9 Raised 0.0 0.00 0.0 Base Total: -4801.8 As-Built Total: 161.0 -4816.9 INFIL TRA TION Area X BSPM = Points Area X SPM = Points 1002.5 14.31 14346.3 1002.5 14.31 14346.3 ~nOr"\I~~llnotli\ nr:4 ~nrrn RnnA_?M1 J:nQr"\I~~lInCllti'\ll=loQDC(~'?tY\1 1='1 ~f":PR '\~ ~ FORM600A-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T Summer Base Points: 18828.9 Summer As-Built Points: 18619.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x OSM x AHU) 18619.7 1.000 (1.087 x 1.150 x 1.(0) 0.310 1.000 7215.4 18828.9 0.4266 8032.4 18619.7 1.00 1.250 0.310 1.000 7215.4 J:nort"l\~~II"'oTM n('/i. 1:",""" ~A_?I'Vl1 J:nArn\l~~lInclll'\/J:I~"'J:ctl?l'Vl1 1:1 "'''PR \A ~ FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1002.5 5.86 1057.5 Double, Tint N 8.0 5.5 16.2 11.29 0.99 180.3 Double, Tint W 1.0 7.5 16.2 10.07 1.00 163.0 Double, Tint W 1.0 13.5 16.2 10.07 1.00 162.9 Double, Tint E 1.0 16.0 16.2 9.46 1.00 153.5 Double, Tint E 1.0 12.0 16.2 9.46 1.00 153.6 As-Built Total: 81.0 813.4 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.80 2174.4 Exterior 1208.0 2.00 2416.0 Base Total: 1208.0 2416.0 As-Built Total: 1208.0 2174.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 5.10 214.2 Exterior 42.0 5.10 214.2 Base Total: 42.0 214.2 As-Built Total: 42.0 214.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1002.5 0.64 641.6 Under Attic 30.0 1807.9 0.64 X 1.00 1157.0 Base Total: 1002.5 641.6 As-Built Total: 1807.9 1157.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 151.O(p) -1.9 -286.9 Slab-On-Grade Edge Insulation 0.0 151.0(p 2.50 3n.5 Raised 0.0 0.00 0.0 Base Total: -286.9 As-Built Total: 151.0 377.6 INFIL TRA TION Area X BWPM = Points Area X WPM = Points 1002.5 -0.28 -280.7 1002.5 -0.28 -280.7 I=nArn\~QII"otR\ n,.. 6. I:'nrrn RnnA_?tV\1 I=nCllr"'\I~o::IllnGtS"l/-=I'l:Ig-=c::.1?t'V'\1 ~I J)r:PR \A. ~ FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T Winter Base Points: 3761.7 Winter As-Built Points: 4455.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x OSM x AHU) 4455.9 1.000 (1.078 x 1.160 x 1.00) 0.455 1.000 2535.6 3761.7 0.6274 2360.1 4455.9 1.00 1.250 0.455 1.000 2535.6 I:nArl'l\~~II"a TM nr- A ~n""" RtYl6_?t'V'l1 I:n,c,rn\l~~llnAl1i'lJt=I'l:lII=)I:c:.'?M1 ~I J:)('PR,~ ~ FORM .600A-2001 .'WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2564.00 5128.0 20.0 0.97 2 1.00 2326.10 1.00 4652.2 As-Built Total: 4652.2 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 8032 2360 5128 15521 7215 2536 4652 14403 I PASS I I=nArl"l\tn!l:lllnQTM nr:A ~nrrn RIYlA_?M1 ~nAr"\J~~llnGtfi'\/~kilj:)S:~1')M1 1=1 I:)("DR \~ ~ FORM 600A-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmlsa.ft. window area' .5 cfmlsa.ft. door area. Exterior & Adjacent Walls 606.1 .ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sale or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & toplbottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the too olate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the oerimeter. oenetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the oerimeter at oenetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/'2:' clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned soace tested. Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavitY between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES fmust be met or exceeded bv all residences.l COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with effICiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (aas) must be DrovicJecl. External or built-in heat traD reauired. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). NOlKXlmmercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiencv of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG. Air Distri>ution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Seoarate readilY accessible manual or automatic thermostat for each sYStem. Insulation 604.1 , 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. I:'nOrt"l\.ln~111"'lQ 1M n,... A I:'nnn RtYl4._ ')(V'\1 I:'nCllr""/~~llnlClt&\/a::I'2I=)i=~1?tV\1 ~J ~""CR \A ~ ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score, the more efficient the home. Sean & Heather Zirbel, 5430 18th street, Zephyrhills, FL, 33542- 1. New construction or existing 2. Single family or multi-family 3. Number of units, if multi-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SHGC - single pane d. Tint/other SHGC - double pane 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9 . Wall types a. Frame, Wood, Exterior b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Garage b. N/A Single Pane 0.0 ft2 0.0 ft2 0.0 ft2 Addition Single family 1 2 No 1002.54 ft2 Double Pane 0.0 ft2 81.0 ft2 0.0 ft2 12. Cooling systems a. Central Unit Cap: 24.0 kBtulhr SEER: 11.00 R=O.O, I 51.0(p) ft R=13.0, 1208.0 ft2 R=30.0, 1807.9 ft2 Sup. R=6.0, 250.0 ft b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 24.0 kBtulhr HSPF: 7.50 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 20.0 gallons EF: 0.97 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86for a US EPA/DOE EnergyStJ~ designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contactthe Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site atwww.fsec.ucfedufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge@ (Version: FLRCPB v3.30) Residential System Sizing Calculation Summary Project Title: Zirbel Addition Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- Code Only Professional Version Climate: Central Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet bulb 6 Humidit difference 44 r. Winter design temperature 38 F Summer design temperature Winter setpoint 70 F Summer setpoint Winter tern erature difference 32 F Summer tern rature difference Total heatin load calculation 14603 Btuh Total coolin load calculation Submitted heating capacity % of calc Btuh Submitted cooling capacity Total (Electric Heat Pump) 164.4 24000 Sensible (SHR = 0.5) Heat Pump + Auxiliary(O.OkW) Latent Total Electric Heat Pum 93 F 75 F 18 F 13476 Btuh % of calc Btuh 111 .1 12000 448.9 12000 WINTER CALCULATIONS Winter Heatin Load Load com nent Window total Wall total Door total Ceiling total Floor total Infiltration Subtotal Duct loss TOTAL HEAT LOSS 81 sqft 1208 sqft 42 sqft 1808 sqft 151 ft 67 cfm Load 1878 3141 632 1989 3911 2357 13907 695 14603 Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Doors(4%) SUMMER CALCULATIONS Summer Coolina Load (for 1003 soft Load comDonent Load Window total 81 sqft 1166 Btuh Wall total 1208 sqft 2102 Btuh Door total 42 sqft 426 Btuh Ceiling total 1808 sqft 2567 Btuh Floor total 0 Btuh Infiltration 59 cfm 1160 Btuh Internal gain 2400 Btuh Subtotal(sensible) 9821 Btuh Duct gain 982 Btuh Totall sensible gain 10803 Btuh Latenl gain(infiltration) 1753 Btuh Latenl gain(internal) 920 Btuh Totali latent gain 2673 Btuh TOTAL HEAT GAIN 13476 Btuh Int.Gain(16%) Infil.(9%) EnergyGaugecfi> System Sizing.. PREPARED BY: DATE: ::2. EneravGauae<R> FLRCPB v3.30 Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- System Sizing Calculations - Winter Residential Load - Component Details Project Title: Zirbel Addition Code Only Professional Version Climate: Central Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F 2/18/04 Window PaneslSHGC/Frame/U Orientation Area X HTM= Load 1 2, Tint, Metal, DEF E 16.2 23.2 376 Btuh 2 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh 3 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh 4 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh 5 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh Window Total 81 1878 Btuh Walls Type R-Value Area X HTM= Load 1 Frame - Exterior 13.0 1208 2.6 3141 Btuh Wall Total 1208 3141 Btuh Doors Type Area X HTM= Load 1 Insulated - Exter 42 15.0 632 Btuh Door Total 42 632Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 1808 1.1 1989 Btuh Ceilina Total 1808 1989Btuh Floors Type R-Value Size X HTM= Load 1 Slab-On-Grade Edge Insul 0 151.0 ft(p) 25.9 3911 Btuh Floor Total 151 3911 Btuh Infiltration Type ACHX Building Volume CFM= Load Natural 0.40 10025(sqft) 67 2357 Btuh Mechanical 0 o Btuh Infiltration Total 67 2357 Btuh Subtotal 13907 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05 695 Btuh Total Btuh Loss 14603 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U-Factor or 'OEP for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for s1ab-on-grade or area for all other floor types ) EneravGauae@ FLRCPB v3.30 Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- System Sizing Calculations - Summer Residential Load - Component Details Project Title: Zirbel Addition Code Only Professional Version Climate: Central Reference City: Orlando (Defaults) Summer Temperature Difference: 18.0 F 2/18/04 Type Overhang Window Area(sqfl) HTM Load Window PaneslSHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded 1 2, Tint, DEF, B, N E 8 5.5 16.2 16.2 0.0 12 35 194 Btuh 2 2, Tint, DEF, B, N N 1 7.5 16.2 0.0 16.2 12 12 194 Btuh 3 2, Tint, DEF, B, N N 1 13.5 16.2 0.0 16.2 12 12 194 Btuh 4 2, Tint, DEF, B, N S 1 16 16.2 0.0 16.2 12 18 291 Btuh 5 2, Tint, DEF, B, N S 1 12 16.2 0.0 16.2 12 18 291 Btuh Window Total 81 1166 Btuh Walls Type R-Value Area HTM Load 1 Frame - Exterior 13.0 1208.0 1.7 2102 Btuh Wall Total 1208.0 2102 Btuh Doors Type Area HTM Load 1 Insulated - Exter 42.0 10.1 426 Btuh Door Total 42.0 426 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark 30.0 1807.9 1.4 2567 Btuh Ceilino Total 1807.9 2567 Btuh Floors Type R-Value Size HTM Load 1 Slab-On-Grade Edge Insulation 0.0 151.0 ft(p) 0.0 0 Btuh Floor Total 151.0 0 Btuh Infiltration Type ACH Volume CFM= Load Natural 0.35 10025 58.6 1160 Btuh Mechanical 0 o Btuh Infiltration Total 59 1160 Btuh Occupants 4 Btuh/occupant X 300 + Appliance 1200 Load 2400 Btuh Subtotal 9821 Btuh Duct gain(using duct multiplier of 0.10) 982 Btuh Total sensible gain 10803 Btuh Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 1753 Btuh Latent occupant gain (4 people @ 230 Btuh per person) 920 Btuh Latent other gain 0 Btuh TOTAL GAIN 13476 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - Window U-Factor or 'DEF' for default) (InSh - Interior shading device: none(N), BlindslDaperies(B) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (Omt - compass orientation) EnerovGauae<ll) FLRCPB v3.30 FORM 600A-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Address: City, State: Owner: Climate Zone: Zirbel Addition 5430 18th street Zephyrhills, FL 33542- Sean & Heather Zirbel Central Builder: Pennitting Office: Permit Number: Jurisdiction Number: 1. New construction or existing 2. Single family or multi-family 3. Number of units, ifmulti-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (Ii>) 7. Glass area & type a. Clear glass, detault U-factor b. Default tint c. Labeled U or SHGC 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Garage b. N/A Sing.lePane 0.0 ftZ 0.0 ft2 0.0 ftZ Addition SinglelamiIy I 2 No 1002.54 ft2 Double Pane 0.0 ftZ 81.0 ft2 0.0 ft2 R=O.O, 151.0(p) ft R=13.0. 1208.0 ft2 R=300. 1807.9 ft2 Sup. R=6.0. 250.0 ft I 12. Cooling systems a. Central Unit Cap: 24.0 kBtulhr SEER: 11.00 b. N/A . c. N/A 13. Heating systems a. Electric Heat Pump Cap: 24.0 kBtu!hr HSPF: 7.50 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 20.0 gallons EF: 0.97 b. N/A c. Conservation credits (HR-Heat recovery. Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan. CV-Cross ventilation. HF-Whole house Ian. PT-Programmable Thermostat MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.08 Total as-built points: 14403 Total base points: 15521 PASS I hereby certify that the plans and specifications covered by this calculation are in.. compo Iiance with the FlofYrida Energy Code. . , __ 4 PREPAREDBY~~~~ DATE: :)./q.o~ -- I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: ~n'>r"\I~"""cIli\ (\/or.,,,,n. J:'I RrOl:l ,,':I ':In\ Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFI DATE: FORM 600A-2001 SUMMER CALCULATIONS Residential Whole BuHding Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1002.5 25.78 4652.2 Double, Tint N 8.0 5.5 16.2 20.63 0.67 225.0 . . Double, Tint W 1.0 7.5 16.2 40.60 0.99 648.6 Double, Tint W 1.0 13.5 16.2 40.60 1.00 654.6 Double, Tint E 1.0 16.0 16.2 45.16 1.00 728.5 Double, Tint E 1.0 12.0 16.2 45.16 1.00 727.6 As-Suilt Total: 81.0 2984.2 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.70 2053.6 Exterior 1208.0 1.90 2295.2 Base Total: 1208.0 2295.2 As-Suilt Total: 1208.0 2053.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 42.0 4.80 201.6 Exterior 42.0 4.80 201.6 Base Total: 42.C 201.6 As-Built Total: 42.0 201.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1002.5 2.13 2135.4 Under Attic 30.0 1807.9 2.13 X 100 3850.8 Base Total: 1002.5 2135.4 As-Suilt Total: 1807.9 3850.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 1510(p) -318 -4801.8 Slab-On-Grade Edge Insulation 0.0 151.0(p -31.90 -4816.9 Raised 0.0 0.00 0.0 Base Total: -4801.8 As-Suilt Total: 151.0 -4816.9 INFILTRATION Area X BSPM = Points Area X SPM = Points 1002.5 14.31 14346.3 1002.5 14.31 14346.3 ~nAr""~~II"AI1ft nr ~ J:nrrn ~nA_ ..,nn1 !:"Ar""~':::llIIf"uw1i"j:'I~D-=~'..,nn1 ~I Q("C!:l \1'11.n FORM 600A-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T Summer Base Points: 18828.9 Summer As-Built Points: 18619.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x OSM x AHU) 18619.7 ,1.000 (1.087 x 1.150 x 1.00) 0.310 1.000 7215.4 18828.9 0.4266 8032.4 18619.7 1.00 1.250 0.310 1.000 7215.4 t:n,Qr"'''(-::~II'''AfM n,...~ ~nrn"t '::(YHL,)1Y\1 !::ru:lor"'~21Inalii\/I:'I~I;t-=c:::'..,nn1 1:'1 P("'OI:): \/~ ~n FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1002.5 5.86 1057.5 Double, Tint N 8.0 5.5 16.2 11.29 0.99 180.3 Double, Tint W 1.0 7.5 16.2 10.07 1.00 163.0 Double, Tint W 1.0 13.5 162 10.07 1.00 162.9 . Double, Tint E 1.0 16.0 16.2 9.46 1.00 153.5 Double, Tint E 1.0 12.0 16.2 9.46 1.00 153.6 As-Suilt Total: 81.0 813.4 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 13.0 1208.0 1.80 2174.4 Exterior 1208.0 2.00 2416.0 Base Total: 1208.0 2416.0 As-Suilt Total: 1208.0 2174.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Extenor Insulated 42.0 5.10 214.2 Exterior 42.0 5.10 214.2 Base Total: 42.0 - 214.2 As-Suilt Total: 42.0 214.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1002.5 0.64 641.6 Under Attic 30.0 18079 0.64 X 1.00 1157.0 Base Total: 1002.5 641.6 As-Built Total: 1807.9 1157.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 1S1.0(p) -1.9 -286.9 Slab-On-Grade Edge Insulation 0.0 151.0(p 2.50 3n.S Raised 0.0 0.00 0.0 Base Total: -286.9 As..auilt Total: 151.0 3n.5 INFIL TRA TION Area X BWPM = Points Area X WPM = Points 1002.5 -0.28 -280.7 1002.5 -0.28 -280.7 !:"Orn\,r.:~II"afIi'\ nf"A 1:''''........ ~4_")('V11 !:"Ar"\I~~II,..GIIt1i'\/!:'I'2IQ-=~1">f"V\1 1:'1 I;t("OR \I~ ~ FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T Winter Base Points: 3761.7 Winter As-Built Points: 4455.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 4455 9 1.000 (1.078 x 1.160 x 1.(0) 0.455 1.000 2535.6 3761.7 0.6274 2360.1 4455.9 1.00 1.250 0.455 1.000 2535.6 t::nQrrn,~:=aII"'QrM nr~ ~n,..,..., ~.6_-:f'V'\1 !::f""~I"'''\I~:aII"ai1i\I-=I~j:)~~'..,nn1 C'I orPR Ill. ':If' FORM 600A-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2564.00 5128.0 20.0 0.97 2 1.00 2326.10 100 4652.2 As-Built- otal: 4652.2 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Tot~ ; Cooling + Heating + Hot Water = Total Points Points Points Pair '5 Points Points Points Points 8032 2360 5128 155~ 1 7215 2536 4652 14403 u\SS I i=n.Qr"\lr::~II".aTM n,...~ ~,...."'" ~A_"M1 ~"or""/~::IlI"otii\JC'I~g~~''''(VH ~I O('OQ u-:t ~n FORM 600A-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details PERMIT #: ADDRESS: 5430 18th street, Zephyrhills, FL, 33542- 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST 6A-2 OTHER PRESCRIPTIVE MEASURES must b~ met or exceeded b all residences. COMPONENTS SECTION REQUIREMENT: Water Heaters 612.1 Comply with effic'. .ncy requirements in Table 6-12. Switch or cleanv marked circuit breaker electric. r cutoff as must be rovided. External or bullt-,n heat tra r U1red. Spas & heated p<ois must have covers (except solar heated). NOrKOmmercial pools must have a pum' timer. Gas spa & pool heaters must have a minimum thermal effiCiency of 78~ Water flow must e restricted to no more than 2.5 allons r minute at 80 PSIG. All ducts, fittings -nechanical equipment and plenum chambers shait be mechanically attacned, sealeo, ,1SUlated, and installed in accordance with the cmeria of Section 610. Ducts in uncondlkmed attics: R-6 min. insulation. Seoarate readily c!:~cessible manual or automatic thermostat for eacn stem. Ceilings-Min. R- 'i Common walls-Frame R-11 or CBS R-3 both SiOes Common ceiling <:. rloors R-11 . COM NENTS Exterior Windows & Doors Exterior & Adjacent Walls SECTION i 606.1.ABC.1.1 i 606.1.ABC.1.2.1 I Floors 1606.1.ABC.1.2.2 Ceilings 606.1.ABC.1.2.3 Recessed Lighting Fixtures !606.1.ABC.1.2.4 Multi-sto Houses Additional Infiltration reqts 606.1.ABC.1.2.5 606.1.ABC.1 .3 Swimming Pools & Spas 612.1 Shower heads Air Distribution Systems 612.1 : 610.1 HVAC Controls 607.1 604.1, 602.1 Insulation =I"'IQr"''''~-:lII'''QTM nrl\. i=nrn"l ~nnA_"f"\('\1 I REQUIREMENTS FOR EACH PRACTICE ! Maximum:.3 cff!1l .ft. window area. .5 cfml .ft. door area. Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. i EXCEPTION: Frame walls where a continuous infiltration barrier is Installed that extends I : from, and is sealed to the foundation to the to late. I Penetrations/openings >1/8" sealed unless backed by truss or joint members. : EXCEPTION: F 'ame tIoor$ where a continuous infiltration barrier's installed that is sealed to the rimeter ::>enetrations and seams. Between walls & ceilings; penetrations of ceiling plane of top floor. around shafts, chases, soffits, chimneys. cabinets sealed to continuous air barrier; gaps in gyp board & top plate; , attic access. EYCEPTION: Frame ceilings where a continuous infiltration barrier is , installed that is;ealed at the rimeter at netrations and seams. Type IC rated With no penetrations, sealed; or Type IC or non-IC rated, Installed inside a sealed box with 2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from I conditioned s ", tested. Air barrier on r---,eter of floor cavi between floors. Exhaust fans veil, ~ to outdoors, dampers; combustion space hearers comply with NFPA. ; have combustion.lr. CHECK CHECK ;:nar"\I~c:JII,.,Clliin/~I-=-g~C:::""'f'Vl1 1:'1 i::)rCR \/~ <n ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMA TED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score. the more efficient the home. Sean & Heather Zirbel, 5430 18th street, Zephyrhills, FL, 33542- I. New construction or existing 2. Single fiunily or multi-fiunily 3. Number of units, if multi-tamily 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SHGC - single pane d. Tint/other SHGC - double pane 8. Floor types a. SlalrOn-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame. Wood. E:-..'terior b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N;A I I . Ducts a. Sup: Vnc. Ret: Vnc. AH: Garage b. N/A Addition Single fiunily I Single Pane 0.0 ft2 0.0 ft2 0.0 ft2 No 1002.54 ft2 Double Pane 0.0 ft2 81.0 ft2 0.0 ft2 12. Cooling systems a. Central Unit Cap: 24.0 kBtulhr SEER: 11.00 R=O.O. 151.01p) ft R=13.0. 1208.0 ft2 .R=30.0. 1807.9 ft2 Sup. R=DO. 250.0 ft 2 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 24.0 kBtulhr HSPF: 7.50 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 20.0 gallons EF: 0.97 b. N/A c. Conservation credits (HR-Heat recoveTV. Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceiling tan. CV-Cross ventiIauon.. !-IF-Whole house tan. PT-Programmable Thermostat. MZ-C-Multizone cooling, MZ-H-Multizone heating) r certifY that this home has complied \\lIh [he Florida Energ' Efficiency Code For Building Construction through the above energy sa\ing features whid, will be installed (or exceeded) in this home before final inspection. Otherwi.se. :1 new EPL .'isplay Card will be completed based on installed Code compliant tearures. Builder Signature: Address of New Home: )ate: .:::ity/FL Zip: *NOTF;: The home's eSTImated energy performance score is on(v available through the FLtRES c'OI7WUler program. This is 1'1!2! a Building Fnergy Raling. J\our score IS 80 or sreater (or 86 jor a (,5' EP. l.DOE Ener<::. ,,'toff deSignatIOn;, ,\lOUr home may qualifY/or energv ejJiClencv mortgage I EEA1) incentives if you obtain a FlOrida Ene",:,,:, Gauge Racing. (.'antact the Aller~ Gauge Hotline at _;::.. t538-i ../92 or see the Energy (rauge web sile al www.l,~ec. :",.'.edu flJr mfhrmation and (I list o(certijied Raters. ,C;-or inf()rmalion aboul l'1orllla's Energy EjJiciencv CJue i;'r Building ( 'on.wnlclion. ':ontact the Department olCommuml1'. Ufmrs af "5U.J87-182~. EnergvGauge''w (Version: FLRCPB \3.30) Residential System Sizing Calculation Summary Project Title: Zirbel Addition Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- Code Only Professional Version Climate: Central Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet buib 76 Humidit difference 44 r. Winter design temperature 38 F Summer design temperature Winter setpoint 70 F Summer setpoint Winter tem erature difference 32 F Summer tem erature difference Total heatin load calculation 14603 Btuh Total coolin load calculation Submitted heating capacity % of calc Btuh Submitted cooling capacity Total (Electric Heat Pump) 164.4 24000 Sensible (SHR = 0.5) Heat Pump + Auxiliary(O.OkW) Latent Total Electric Heat Pum Winter Heatin Load Load com onent Window total Wall total Door total Ceiling total Floor total Infiltration Subtotal Duct loss TOTAL HEAT LOSS Summer Coolin Load Load com onent Window total Wall total Door total Ceiling total Floor total Infiltration Internal gain Subtotal(sensible) Duct gain Toted sensible gain Latent gain(infiltration) Latent gain(internal) Total latent gain TOTAL HEAT GAIN 93 F 75 F 18 F 13476 Btuh % of calc Btuh 111.1 12000 448.9 12000 . -WINTER CALCULATIONS ft Ducts(5%) Load ~ ''-lindowst13%) \ i ~', 81 sqft 1878 BtLh !nnl (16%) /'/ \,; """"_-. \ I ' ~ I \ i ~\ 1208 sqft 3141 Bttn / \ : ' . C~Ij;ncS -~7?) / \ I 42 sqft 632 BtLl .. ; I ,_______ \ i 1808 sqft 1989 BtL."1 :JoorS(4%I, ___-------]/. I '. --------, 151 ft 3911 Btt '1 \ , 67 cfm 2357 BtLl " J , 13907 Btl.. fl I // '-'Valls(22%) Floors(27%) "- " 695 BtLn, , ~-~~ 14603 BtL!!J 81 sqft 1208 sqft 42 sqft 1808 sqft 59 cfm SUMMER <;ALCULATIONS ft Load '~ ~~~~ ::~~ 426 Bh:n 2567 BtDn o Btu h 1160 Btun 2400 Stuh 9821 Btuh 982 Stuh 10803 Btuh 1753 Btuh I 920 Stuh 2673 Btuh 13476 Btuh EnerovGauoeOO FLRCPB v3 30 Latent ln1emal(1~~~.It"dOW'S19%) '\ i '. \, (--~:~----- -- , ' '\ :'ll.l:'~lOfl0":':,) I" Lilterrt rnfil (13%).... / l' ,..thn~<;l .~ -"':, 'I " \ , , , W~IIS(lh",,*' , ! Ducts(7%) "'.i.. -,/ nlil (9%) 'onrs(3"hl Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- System Sizing Calculations - Winter Residential Load - Component Details Project Title: Zirbel Addition Code Only Professional Version Climate: Central Reference City: Orlando (Defaults) Winter Temperature Difference: 32.0 F 2/18/04 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 2, Tint, Metal, DEF E 16.2 23.2 376 Btuh 2 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh 3 2, Tint, Metal, DEF N 16.2 23.2 376 Btuh 4 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh 5 2, Tint, Metal, DEF S 16.2 23.2 376 Btuh Window Total 81 1878 Btuh Walls Type R-Value Area X HTM= Load 1 Frame - Exterior 13.0 1208 2.6 3141 Btuh Wall Total 1208 3141 Btuh Doors Type Area X HTM= L~ad 1 Insulated - Exter 42 15.0 632 Btuh Door Total 42 632Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 1808 1.1 1989 Btuh Ceilina Total 1808 1989Btuh Floors Type R- Value Size X HTM= Load 1 Slab-On-Grade Edge Insul 0 151.0 ft(p) 25.9 3911 Btuh Floor Total 151 3911 Btuh Infiltration Type ACHX Building Volume CFM= Load Natural 0.40 10025(sqft) 67 2357 Btuh Mechanical 0 o Btuh Infiltration Total 67 2357 Btuh Subtotal 13907 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05 695 Btuh Total Btuh Loss 14603 Btuh Key: Window types (SHGC - Shading coeffiCIent of glass as SHGC numerical value or as clear or tint) (Frame types - metal. wood or insulated metal) (U - Window U-Factor or 'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab-on-grade or area for all other floor types) EneravGauoeOO FLRCPA v3 30 Sean & Heather Zirbel 5430 18th street Zephyrhills, FL 33542- System Sizing Calculations - Summer Residential Load - Component Details Project Title: Zirbel Addition Code Only Professional Version Climate: Central Reference City: Orlando (Defaults) Summer Temperature Difference: 18.0 F 2/18/04 Type Overhang Window Area(sqft) HTM Load Window PanesJSHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded 1 2, Tint, DEF. S, N E 8 5.5 16.2 162 0.0 12 35 194 Btuh 2 2. Tint. DEF. S, N N 1 7.5 '6.2 0.0 16.2 12 12 194 Btuh 3 2, Tint, DEF, S, N N 1 13.5 '6.2 0.0 16.2 12 12 194 Btuh 4 2, Tint, DEF. S, N S 1 16 '6.2 0.0 16.2 12 18 291 Btuh 5 2, Tint, DEF, S, N S 1 12 16.2 0.0 16.2 12 18 291 Btuh Window Total 81 1166 Btuh Walls Type R-Value Area HTM Load 1 Frame - Exterior 13.0 1208.0 1.7 2102 Btuh Wall Total 1208.0 2102 Btuh Doors Type Area HTM Load 1 Insulated - Exler 42.0 10.1 426 3tuh Door Total 42.0 426 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under A!tici Dark 30.0 1807.9 1.4 2567 3tuh Ceilina Total 1807.9 2567 Btuh Floors Type R-Value Size HTM Load 1 Slab-On-Grade Edge Insulation 0.0 151.0/t(p) 00 J Btuh Floor Total 151.0 . 0 Btuh . Infiltration Type ACH Volume CFM= Load Natural 0.35 10025 58.6 1160 3tuh Mechanical 0 ] 8tuh Infiltration Total 59 1160 Btuh Occupants 4 Btuh/occupant X 300 + Appliance 1200 Load 2400 Btuh Subtotal 9821 Btuh Duct gain(using duct multiplier of 0.10) 982 Btuh Total sensible gain 10803 Btuh Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 1753 Btuh Latent occupant gain (4 people @ 230 Btuh per person) 920 Btuh Latent other gain 0 Btuh TOTAL GAIN 13476 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numencal value or as clear or tint) ,U - Window U-Factor or 'DEF' for defauit) i.lnSh - ,nterior shading device: none(N), BlindslDaperies(B) or Roller Shades(R\) I ExSh . Exterior shading device: none(N) or numerical value) (Omt - ~ompass onentation) EnernvGauaeOO FLRCPB v3 30