Loading...
HomeMy WebLinkAbout04-2852 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 2852 Permit Number: 2852 Issued: 3/22/2004 Permit Type: GENERAL BUILDING PERMIT Class of Work: SLAB Proposed Use: MEDICAL Sq. Feet: Est. Value: Cost: 20,000.00 Total Fees: Amount .paid: 200.00 Date Paid: Address: 7050 GALL BLVD ZEPHYRHILLS, FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: Name: DOSTER CONST. CO. INC Addr: 2619 COMMERCE BLVD BIRMINGHAM,AL. 35210-1211 Phone: Lic: --Work Desc: FOUNbA TION ONLY Name: EAST PASCO MEDICAL CENTER Address: 7050 GALL BLVD ZEPHYRHILLS, FL. 33542 Phone: ._._--~----~~-------_.__._._-._- s -- ,hot ~ ?<<.cls I i 6-3o~ WJb 1 I U 2ND ROUGH PLUMB DUCTS INSULATED WATER FINAL MECHANICAL FRAME i MISC SEWER MISC INSULATION WALL I MISC i MISC. MISC. INSULATION CEILING MISC. I MISC, I . MISC. DRIVEWAY I MISC. i MISC. FIRE DEPT. FINAL . -_.________m___m_____...___=__L~._.____..___...__._...-.....-.-----.l-.--_________.~..L___...____.______m__.. REINSPEcnON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible .1_Ibej)~Y_'!1~~t.E~_ir1~~iOrl fee~ _~all__~e m~de~~forei'l_~Y ~urtt1.~r~~mits.~L~~ isslJed to_ th~J>~rson owni!1.9~arn~______ _ "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for I improvements to your property. If you intend to obtain financing, consult with your lender or an attorney I?~!c>>_re r~ord~l1g Y..!-llir n()tice_()f comm~ncel1'len~=___________________________ rJ. NO OCCUPANCY BEFORE C.O. ------- --~----- -- _J I NATURE PERM IT OFF! LL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS PERMIT APPLICATION BUILDING DEPARTMENT 5335 aD St, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECE IVED PHONE CONTACT FOR PERMITTING &, -3 q - 7 ~ 3 tf PA..Ut.. L()tJ~6~()P-'1 PHONE 7'8~ ~ 04// OWNER'S NAME l;;:4St /)A-':::>W JilQ\,C-4L-C J;::iJl~ 70S- D ;';4-LL ~ li/1., JOB ADDRESS LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION PARCEL ID # WORK PROPSED: [JNEW CONSTRUCTION [J SIGN XADDI T ION [J MOVE (OBTAIN FROM PROPERTY TAX NOTICE) [JALTERATION o DEMOLISH o REPAIR [J INSTALL PROPOSED USE: [JSGL FAMILY DWELLING [J COMMERCIAL [JMULTI-FAMILY [J INDUSTRIAL [J# OF UNITS o SWIMMING POOL [J MOBILE HOME ~THER DESCRIPTION OF WORK c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL A'tV3ti7f)~ V- ~-,..v;llmnN 1JF l-kx~r17k- .- .fotJ"iNJ-ntYN~ lJIJ!/- BUILDING SIZE SQUARE FOOTAGE HEIGHT RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. AMP SERVICE & (1) SET ENERGY FORMS. FORMS. Eu=ie-nLJT I~ A;\\O l)l~Y~~. 5 ~.. Ll. r _ ~O YN PERMITS REQUESTED btl-- <3f.It~lU l pJj,lL~ITT0 C~rLn7~ VALUATION OF TOTAL CONSTRUCTION [rStJ""-1L -ro 'TIt") MZ [J FLORIDA POWER [J W.R.E.C. ~'L~~. ~ SulP".lIVll) plW1.MT t> "f ~ \.."1 Y\.1-lJ} d!:- VALUATION OF MECHANCIAL INSTALLATION flpfL1ui1i....'" rl:f.\. f (l.JU4I1 J T . ----- ~J 8'S ~ ~BUILDING [J ELECTRICAL $ ~. DrJO [J PLUMBING [J MECHANICAL $ [JGAS [J ROOFING o SPECIALTY o OTHER TYPE OF CONSTRUCTION: [J BLOCK [J FRAME [J STEEL [J OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREA[J YES [J NO BUILDER iiJ um SIGNATURE **:*!....H'...**HH**H*...:~~~:*~:~~*~~*:~~:~*:*:~~~~ 117/ CONTM,CTOa."SECTION COMPANY Do5lq2 CIJ #;f: C-o~ L-LC:r ELECTRICIAN COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** PLUMBER COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** MECHANICAL COMPANY SIGNATURE STATE CERT OR REGIST # ***************************************************************** OTHER COMPANY SIGNATURE STATE CERT OR REGIST # A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed restrictionsH which may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign po~tions of the "Contractor SectionsH of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indica~ion that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "ownerH, I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone "AH or "A,etc.H, it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned fora period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT". SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR acknowledged ,20_ STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____day of by STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____ day of by acknowledged , 20 (name of person acknowledged) Dwho is personally known to me, or (name of person acknowledged) C1ho is personally known to me, or of identification) take an oath. Dwho has produced (type of identification) and who Ddid Odid not take an oath Dwho has produced (type and whoD did 0 did not Signature of person taking acknowledgement Signature of person taking acknowledgment Name typed, printed or stamped Name typed, printed or stamped MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com December 7, 2004 City of Zephyrhills Building Department 5335 8th. Street Zephyrhills, FI. 33542 Attn: William Burgess Certified Building Inspector Re: Threshold Inspection Reports Permit # 2852 East Pasco Hospital Sir, Attached please find our threshold inspection reports number #3 through #10 for the above referenced project. These reports cover inspections made from October 22,2004 to December 7,2004. If you require additional information, please do not hesitate to contact our office. Respectfully submitted Cc: East Pasco Hospital [(1 )-Field Copy & (1) office copy] RBK Architects File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: October 22,2004 1214.167 0.003 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: [J Inspection of retaining wall foundation along gridline 0, between 5 and 8. Spread footing foundation at location 0/12. Reinforcing quantity and type is in accordance with the contract documents and is ok to pour concrete on the projected day of October 23,2004. Pending Issues: None at this writing Respectfully submitted 1lJjU Robert L. Bell, E.I. ~~/~;;fty ~ { Armando A Castellon, P.E. FI. Reg. # 43,453 SI # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: November 03,2004 1214.167 0.004 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: II Inspection of elevator foundation along gridline 7, between E and G. Reinforcing quantity and type is in accordance with the contract documents and is ok to pour concrete on the projected day of November 04, 2004. Pending Issues: None at this writing Respectfully submitted 1/.1 /&11 Robert L. Bell, E.1. ~/?/?)r Armando A Castellon, P.E. FI. Reg. # 43,453 81 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: November 10,2004 1214.167 0.005 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: rJ Inspection of elevator pit wall reinforcing at main bank of elevators. C Inspection of spread footing reinforcing at locations 6-E, 5-E,and 4-E. [j Inspection of wall foundation steel along gridline 2 from C to D. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, 12/1 &If Robert L. Bell, E.1. ~ IZfP<( ./Armando A Castellon, P.E. . FI. Reg. # 43,453 SI # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 www.mcengineers.com Report Photographs - November 03, 2004 MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: November 17,2004 1214.167 0.006 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.I. Items Inspected: rJ Inspection of foundations along gridline 12 at E and F. / (1-8) / (11/12-E) / (E-11 & 12), 11 Inspection offoundation along gridline 10 at H. lJ Inspection of foundation along gridline 8 at I. [] Inspection of foundation along grid line E at 10 and 11. [J Inspection of wall foundation steel along gridline D from 6 to 10. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, ~IM ~../. ~'1 Armand<> A Castellon, p-zj Fl. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: November 22,,2004 1214.167 0.007 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: D Inspection offoundations along gridline 12 at E and F. / (1-8) / (11/12-E) / (E-11 & 12), [] Inspection of foundations along gridline G1 and 3-4-5. LJ Inspection of foundation at single elevator pit (1/7). Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, 121 J &f1 Robert L. Bell, E.1. -L'~~ /Z/~'f Armando A Castellon, P.E. FI. Reg. # 43,453 81 # 0931 Cc: ZephyrhiUs Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Arch itect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: November 30,2004 1214.167 0.008 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: [] Inspection of miscellanies foundations adjacent to cafeteria along gridline 11.5. D Inspection of foundation along gridline G and 11. n Inspection of concrete walls at single elevator pit (1/7). Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, ~1&11 Robert L. Bell, E.1. ~~~ /Z/ry Armando A Castellon, P.E. FI. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 6, 2004 1214.167 0.009 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: f] Inspection of mat foundation at gridline H/10. IJ Inspection of foundation along gridline G/10, E.1/3 and E.1/1. [J Inspection of concrete transfer beam along gridline E from 8 to 10. fJ Inspection of mat foundation at gridline A from 9 to 11. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, 11 i zd( Robert L. Bell, E.1. ~ /zP/Y Armando A Castellon, P.E. Fl. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 7,2004 1214.167 0.010 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: [] Inspection of step foundation along gridline 12 from B.3 to A. [J Inspection of retaining wall reinforcing from D to A. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, YJt~ Robert L. Bell, E.1. ~~ /~~ Armando A Castellon, P.E. FI. Reg. # 43.453 81 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com January 6, 2005 City of Zephyrhills Building Department 5335 8th. Street Zephyrhills, FI. 33542 Attn: William Burgess Certified Building Inspector Re: Threshold Inspection Reports Permit # 2852 East Pasco Hospital Sir, Attached please find our threshold inspection reports number #11 through #16 for the above referenced project. These reports cover inspections made from December 9, 2004 through December 30, 2004. If you require additional information, please do not hesitate to contact our office. Respectfully submitted ~ . rfp,f A mando A. Castellon, P.E. Florida P.E. #43.453 Special Inspector #0931 Cc: East Pasco Hospital [(1)-Field Copy & (1) office copy] RBK Architects File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 09, 2004 1214.167 0.011 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: [] Inspection of cast in place retaining wall reinforcing at gridline D from 10 to 12. [::: Inspection of cast in place retaining wall reinforcing at gridline 12 from D to A. n Inspection of spread footings J-5, J-6, J-7, and H-6. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, j} 1 ~Jr ~.L. Bell E.1. ./ - I(~ Armando A Castellon, P.E. Ft. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 14, 2004 1214.167 0.012 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: I] Inspection of spread footings 1-4, J-3, J-5.5, and pier C-8. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing iT~~' Robert L. Bell, E.1. ~ 1/61/ Armando A Castellon, P.E. FI. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1)-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 17, 2004 1214.167 0.013 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: II Inspection of cast-in-place retaining wall reinforcing along grid line D from 2 to 6. Piers C-2.5, and B.4-11. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing ]J{;i~d Robert L. Bell. E.I. Armando A Castellon, P.E. FI. Reg. # 43,453 81 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 20, 2004 1214.167 0.014 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: n Inspection of spread footings at J-10, J-10.5, 1-10, 1-10.5, B.1-7, B.1-8, and pier B1-J. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing i07~m~ed' Robert L. Bell, E.1. ~d~fIo( Armando A Castellon, P.E. f FI. Reg. # 43,453 51 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, I nc [( 1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 22, 2004 1214.167 0.015 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: [I Inspection of transfer beam located at 1-10 to 1-11. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing Respectfully submitted, 111 gJ{8 Robert L Bell, E.1. ~d e-6/~y Armando A Castellon, P.E. 1 FI. Reg. # 43,453 81 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1 )-Field Copy & (1) office copy] File MASTER CONSULTING ENGINEERS, INC. 2907 Bay to Bay Blvd., Suite 201 Tampa, Florida 33629 Phone 813-835-4885 Fax 813-835-5226 e-mail: MCE@mcengineers.com THRESHOLD INSPECTION REPORT Architect: Project Name: Location: Contractor: RBK Architects, Inc. East Pasco Medical Center Zephyrhills, Florida Doster Construction, Inc. Date: Job No.: Report No.: Permit No: December 30, 2004 1214.167 0.016 2852 Engineer: Inspection By: Master Consulting Engineers, Inc. Robert L. Bell, E.1. Items Inspected: Inspection of spread footings C-4, C-5, and C-6. Reinforcing quantity and type is in accordance with the contract documents and is acceptable for placement of concrete in the inspected areas. Pending Issues: None at this writing R1Jti:iled, Robert L. Bell, E.1. Armando A Castellon, P.E. FI. Reg. # 43,453 81 # 0931 Cc: Zephyrhills Building Department RBK Architects Doster Construction, Inc [(1)-Field Copy & (1) office copy] File