BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
3230
Permit Number: 3230 Issued: 7/14/2004
Permit Type: GENERAL BUILDING PERMIT
Class of Work: 434-ADD/AL T RESIDENTIAL
Proposed Use: SINGLE FAMILY RESIDENTIAL
Sq. Feet: Est. Value:
Cost: Total Fees: 52.50
Amount Paid: 52.50 Date Paid: 7/14/2004
Address: 38522 PIEDMONT AVE
ZEPHYRHILLS, FL.
Township: Range:
Lot(s): Block: Section:
Book: Page:
Subdivision: ALPHA VILLAGE
Parcel Number:
Name: HOMEOWNER
Addr:
Phone: Lic:
Work Desc: 6- WINDOWS REPLACEMENT
GARY C OPER
38522 PIEDMONT AVE
ZEPHYRHILLS, FL. 33542
Phone:
EL T
PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED
LINTEL PRE-METER WATER FINAL MECHANICAL
FRAME MISC SEWER MISC
INSULATION WALL MISC MISC. MISC.
INSULATION CEILING MISC. MISC. MISC.
DRIVEWAY MISC. MISC. FIRE DEPT. FINAL
REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement. n
NO OCCUPANCY BEFORE C.O.
~.
S SIGNATURE PERMIT OFF I
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
.
~
Architectural Testing
15 April 2002
Mr. Marsh Fembaugh, Director of Testing
Alside, Window Company
3773 State Road
Akron, Ohio 44309-1365
RE: Masonry Installation of 0201 Double Hung Window, 3' 0" by 6' 0"
Dear Mr. Fembaugh:
At your request, I have performed an installation fastener analyses into masonry
block walls for Alside double hung windows, Model 0201. The testing of the actual
windows was done under AT! project 05-30324.02. The fastener analyses provides a 3'
0" wide by 6' 0" high window with an allowable installation design wind pressure (D.P.)
of +/- 55.0 psf.
To provide this D.P. in a masonry block wall requires 6 Tapcons, each 3/16" in
diameter. There should be 3 Tapcons through each window jamb frame, one near the top,
one at the midheight, and one near the bottom. The minimum penetration of the Tapcons
into solid masonry must be 1-1/4".
These results are appropriate for the size window stated in the first paragraph
above, and any size smaller. If there are any questions about this analyses, please advise
me.
\\]\'f\\ J\1..L
l\I'i?L'{ . '" o1NG
s\\f'J.-LCO ~~U\JU;~T
t>J...\.. WO~GCODES,Fi:crRlCCOD 'eEs
\'RE\l ~ 110NI'J..~, '\..5 ORD~N"
COOr...N ~p~ ILl--
clf'i Of
Sincerely yours,
ARCHITECTURAL TESTING, INC.
ANR:anr
cc: 01-41462
05-30137
t:2aw 71, /foe. ~. &.-_
Allen N. Reeves, P.E.
Director - Engineering Services
/'1- ,,/ VL,7 206:J-
. "H~!ttU"'1
.,.,' --. ".
,"" ... -...i. f,_~ ,';) to. Wit
}"::~';~~:'~;;~.;':':: ~,:':~'\,
~~_-"!.~~-;;~._,"!,,<-:~." fi:,:'J ~..-~--_ ~ '.,
~ .."....~~;.~"T;:~ -'.~._., -,?~'~.a "::tf, :--~
~ "'- .,'y' . ..J!!.' \'''cJ'~''l .. _.
"- I. .,.... or", o!If ~JI . ......
I.... :>.. .... :J ..'." -
-' : ':"')"J:, :, ; '~ ~::
- ----.-- i ~ :--~ ';. '" ~',":,.'I "-:-,,:': ._. .~ ::~ :;
. I") ..,C" J J.,""J J.t ~,;7 oJ ~_ _'.
.4~, ~;\ "~., .~... . -. - -J .;J '.(4. _....":;
',. '\ '.:I'" J ."', .....:'J"
, <.' <> ,--i) '1 ~ "'" . , ~ ">>
.'. ).1\ -It':') 'Yf'O ::P" -'" '" ,~
_ ~- 0 "3 .;).1~""".:\.."
~;,.. .l"l '",.<>".".." "'\~ ~L'
.'~o\J.~ vI#'r"~
. PJ ". .., N A L "'" '. r;.........
~ #(f.~ lra~ "',)!~ '.. ..~....)\
OA1E
eUI'_::'IN
130 Derry Court
York, PA 17402.9405
phone: 717.764.7700
fax: 717.764.4129
www.archtest.com
"lI
<:) lU
- ~
I
J~ n
o-f
~ !
'"
'"
n !
,...
...
~
n
o-f
1> ~
r
(;?
....
t:;j ~
M CJ
:< t:;j
M
.... r
z
t:;j c
CJ N
< <:)
-
n <
CJ ....
~ Z
""0 t:;j
1> CJ
Z <
-<
....
Z
(;?
-I
1>
r
r
1>
-I
....
CJ
Z
r:r",;
-tp
~ 'g"
II q"<
. II
r ~
o-f
f~ , 0 , ...
C(' -f
.
Co) B ~ ..
0
L Co). Co) ...
f IV IV IV lU
. . . "
b ~ fij 1
IV
3: ! ...
1> g .
(;?
CJ
Z
;:0
-<:
<
1>
r-
r-
;~
"(~
N'
~r
,\ \ \\\Uht'.f"
\". JJ . I,
"" ~. Q hc>.~ 'I,
" ....1",. c1 '/
~ ~;. o~f1:~.'. _4'\;( ~...
" :;..11 - ~;~.; ....... ".
~ c:;,. ..~. ....... <" ....
!::" ~;:.......... GO ~ ::\,..: '. .'-...~ ~ ~_.
.." .........., z: tt"'._ ....".~.
.... - c. '. ,-.... ~ ~ ,. c,,-:;,
. ~... ~ ('1 _). ? ~;. :'''.
. 1.,.., o.:r.:~ ... _,f- t.~. . ..." ( ~:.
. ;:~- ""::" m' 0 =\,: f-::
, ~_. { ct.., *-.; r- e.,
~-:hI: 0;. 0 b c.', f?.. __ ,:;.'
" j:~ ., ~ o. 1'" ,~ (>. .-~ ': ~':.":
c ~~ ~..., . '}.. "'I ...
N ~. @ 0,& ~.. ~) ..t:
" i'p ..... .' t:-.. '-. .
~;,.. 'Vt~~..f!H~r:'-'~ c.....~\ ',~.;.,
Jt.( . 4;; 01 ~ ,;) .\."
ht, .n. . . . ",,,,
, r((~ftrm.!' ,\
....
Z
(;?
-I
1>
r
r
1>
-I
....
CJ
Z
..,
1>
Ci?
-I
1""1
Z
M
;:0
(;?
. . ~ ;=1
~ . "2-
- - i~
)( x )(
..., g: ...,
..., IV
. - - ",8'
If!
:p~
+ + '10
+ el
..... ..... .....
I , I
~ 41> CII ."
g CII e!'
CI b
i i i ~
:It :'> 1>
<
I
I
....
III
!! I
1..
;'ll
~-f
tl
"1>
...p
i:
..
!.i
i~
~:
VI!
!:r
....
5'l
.....
l:
....
pO
5[<
"it
..
g:
0\
Ii
irl
...-,
~i
....
~.;;
.....
o.
"'n
..p
:1
~..
. 0
...
~~q~~t~J
. ..r:;: '0 .:-.~ 0: -: ....\i '.
. . ....~.. "0
...:~ . ..!"~;.:~. ;f..:~
..0... .' "." oar. ~."",..
\. ,.... . .. .
ii ,~. :......~.i~ ; ~..~..
. ... ... ..,
;;0
M
<
t::1
~
-I
M
~i5~
oSS:
'~I
-C"g
i~1
~~ t::1
i~ M
'"
n
;;0
......
-0
-l
......
CI
Z
td
-<
AAMAINWWDA 10111.8.2-97
TE8TREPORT8~Y
Rendered to:
AL8IDE WINDOW SYSTEMS
SERlESIMODEL: 0201
TYPE: PVC Double Hung Window
Results
Title of Test Test Specimen #1 Test Specimen #2 Test Specimen #3 Test Specimen #4
AAMA Ratin~ H-LC30 48 x 78 H-LC35 44 x 77 H.;LC45* 44 x 60 H-LC55* 36 x 72
Ooeratim!; Force 28 Ib max. N/A N/A N/A
Air Infiltration 0.16 cfm/~ N/A N/A N/A
Water Resistance Test Pressure 9.0 psf N/A N/A N/A
Uniform Load Deflection Test Pressure 30 psf 35 psf 45 psf 55 psf
Uniform Load Structural Test Pressure :1:45.0 psf :1:52.5 psf :1:67.5 psf :1:82.5 psf
De~.....~ Passed N/A N/A N/A
Forced Entry Resistance Passed N/A N/A N/A
Reference should be made to ATI Report No. 05-30324.05 for complete test specimen
description and data.
.
~
Architectural Testing
MMAlNWWDA 101/1.S.2-97 TEST REPORT
Rendered to:
ALSIDE WINDOW SYSTEMS
3773 State Road
Akron, Ohio 44309-1365
Report No: 05-30324.05
Test Dates: 01/10102
And: 01/23/02
Report Date: 02/18/03
Expiration Date: 01/23/06
Project Summary: Architectural Testing, Inc. (AT!) was contracted to perform tests on four
Series/Model DH6WW/SLOPE, PVC double hung windows at the Veka, me. facility in Fombell,
Pennsylvania. The samples tested successfully met the performance requirements for the
following ratings: Test Specimen #1: H-LC30 48 x 78; Test Specimen #2: H-LC35 44 x 77;
Test Specimen #3: H-LC45* 44 x 60, and Test Specimen #4: H-LC55* 36 x 72. Test specimen
descriptions and results are reported herein.
General Note: An asterisk (*) next to the performance grade indicates that the size tested for
optional performance was smaller than the minimum test size for the product type and class.
Test Specification: The test specimen was evaluated in accordance with AAMAINWWDA
101/I.S.2-97, Voluntary Specifications for Aluminum, Vinyl (pVC) and Wood. Windows and Glass
Doors.
Test Specimen Description:
Series/ModeI: 0201
Type: Poly Vinyl Chloride (PVC) Double Hung Window
Test Specimen #1: H-LC30 48 x 78
Overall Size: 4' 0" wide by 6' 6" high
Top Sash Size: 3' 8-5/8" wide by 3' 1-3/8" high
Bottom Sash Size: 3' 9-5/8" wide by 3' 2-3/8" high
Screen Size: 3' 8-5/16" wide by 3' 2-11/16" high
130 Derry Court
York. PA 17402-9405
phone: 717.764,7700
fax: 717.764.4129
www.archtest.com
05-30324.05
Page 2 of8
Test Specimen Description: (Continued)
Test SDecimen #2: H-LC35 44 x 77
Overall Size: 3' 8" wide by 6' 5" high
Top Sash Size: 3' 4-5/8" wide by 3' 0-7/8" high
Bottom Sash Size: 3' 5-5/8" wide by 3' 1-7/8" high
Test SDecimen #3: H-LC45* 44 x 60
Overall Size: 3' 8" wide by 5' 0" high
Top Sash Size: 3' 4-5/8" wide by 2' 4-1/4" high
Bottom Sash Size: 3' 5-5/8" wide by 2' 5-5/16" high
Test SDecimen #4: H-LC55* 36 x 72
Overall Size: 3' 0" wide by 6' 0" high
Top Sash Size: 2' 8-314" wide by 2' 10-3/8" high
Bottom Sash Size: 2' 9-3/4"wide by 2' 11-3/8" high
The foUowing descriptions apply to all specimens.
Finish: All vinyl was white.
Glazing Details: The sash were exterior glazed with 13/16" thick sealed insulating glass
fabricated from two sheets of 1/8" clear annealed glass and a metal spacer system. The
insulating glass was set onto a double-sided adhesive tape and secured with rigid vinyl
glazing beads.
Frame Construction: The PVC frame was constructed using mitered and welded comer
construction. A rigid PVC adapter was applied to the head.
Sash Construction: The PVC sash were assembled using mitered and welded comer
construction.
Screen Construction: The screen was constructed from extruded aluminum. The comers
were miter cut and secured with comer keys. Fiberglass mesh screen cloth was
held-in-place with a flexible spline.
Test Specimen Description: (Continued)
Weatherstripping:
Description
0.187" backed by 0.200"
high pile with center fin
0.187" backed by 0.260"
high pile with center fin
0.187" backed by 0.260"
high pile with center fin
0.187" backed by 0.350"
high pile with center fin
0.187" backed by 0.550" high
vinyl jacket/foam filled bulb
0.187" backed by 0.300"
diameter, offset vinyl
jacket/foam filled bulb .
1" by 1/2" x 0.250" high
adhesive backed pile pad
Hardware:
Description
Metal cam lock
and keeper
Constant force balance system
with locking tilt shoe
Plastic spring-loaded
tilt latch
Die cast sash tilt pin
PVC sash stop
Ouantity
1 Row
1 Row
2 Rows
1 Row
tRow
lRow
4
Ouantity
2"
4
4
4
4
05-30324.05
Page 3 of8
Location
Lock rail
Head insert, sill, top rail
Sash stiles
Exterior meeting rail (exterior)
Exterior meeting rail (interior)
Bottom rail
Meeting rails, one at each end
Location
Lock rail, 8-1/2" from each end
Two per jamb
Top comers of sash
Bottom comers of sash
Jambs, one at each end
05-30324.05
Page 4 of8
Test Specimen Description: (Continued)
Drainage:
Description
Ouantity
Location
7/8" wide by 3/16"
high weepslot
2
One 2-1/4" from each end of the
exterior sill face (with flaps), one at
each end of the center sill wall
3/4" wide by 3/16"
high weepslot
2
Sill screen track, one at each end
1-1/4" wide by 1/2"
deep weepslot
2
Sill, one at each end of the interior
jamb track
3/8" wide by 1/8"
deep weepslot
4
Bottom sash rail and exterior
meeting rail, one at each end
Reinforcement: The lock rail contained a rectangular shaped, formed steel reinforcement
measuring 0.649" x 0.461" x 0.047" (reference drawing #2707). The exterior meeting rail
and sash stiles contained a "U" shaped steel reinforcement measuring 0.781" x 0.400"
x 0.047" (reference drawing # 2709).
Installation: The unit was installed in a wood buck constructed of Spruce-Pine-Fir
construction lumber and sealed at the exterior perimeter with a silicone sealant. A 3/4" x
3/4" wood stop was applied to the interior and exterior perimeter and secured with 2"
drywall screws spaced approximately 16" on center.
05-30324.05
Page 5 of8
Test Results:
The results are tabulated as follows:
Paragraph
Title of Test - Test Method
Results
Allowed
Test Specimen #1: H-LC30 48 x 78
2.2.1.6.1
2.1.2
Operating Force 28lbs
Air Infiltration per ASTM E 283
@ 1.57 psf(25 mph) 0.16 cfinlW
35 lbs max.
0.3 cfinlW max.
Note #1: The tested specimen meets the performance levels specified ~in AAMAINWWDA
lOl/lS.2-97 for air infiltration.
2.1.3
2.1.4.2
2.2.1.6.2
Water Resistance per ASTM E 547-00
(with and without screen)
WTP = 3.75 psf No leakage
No leakage
Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 37.5 psf(positive) 0.03" 0.179" max.
@ 37.5 psf(negative) 0.03" 0.179" max.
Deglazing Test per ASTM E 987
Top Sash .
ill operating direction at 70 Ibs
Lift Rail
Meeting Rail
0.060"/12%
0.060"/12%
0.500"/100%
0.500"1100%
ill remaining direction at 50 Ibs
Left Stile
Right Stile
0.060"/12%
0.030"/6%
0.500"/100%
0.500"1100%
Bottom Sash
ill operating direction at 70 Ibs
Lift Rail
Meeting Rail
ill remaining direction at 50 lbs
0.060"/12%
0.060"/12%
0.500"/100%
0.500"/100%
Left Stile
Right Stile
0.030"/6%
0.030"/6%
0.500"/1 00%
0.500"/100%
05-30324.05
Page 60f8
Test Results:
Paragraph
Title of Test - Test Method
Results
Allowed
Test Specimen #1: H-LC30 48 x 78 (Continued)
2.1.7
Welded Comer Test
Meets as stated
Meets as stated
2.1.8
Forced Entry Resistance per AAMA 1302.5-76
Tests A through G No entry
No entry
Optional Performance
4.3
Water Resistance per ASTM E 547-00
(with and without screen)
WTP = 9.0 psf No leakage
No leakage
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 45.0 psf (positive) 0.04" 0.179" max.
@45.0psf(negative) 0.06" 0.179"max.
Test Specimen #2: H-LC35 44 x 77
Optional Performance:
4.4.1 Uniform Load Deflection per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 35.0 psf(positive) 0.44" See Note #2
@ 35.0 psf(negative) 0.46" See Note #2
. Note #2: The Uniform Load Deflection test is not an AAMAINWWDA lOln.S.2-97
requirement for this product designation. The data in this report is for information only.
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 52.5 psf(positive) 0.03" 0.163" max.
@ 52.5 psf(negative) 0.03" 0.163" max.
05-30324.05
Page 7 of8
Test Results: (Continued)
Paragraph
Title of Test - Test Method
Results
Allowed
Test Snecimen #3: H-LC45* 44 x 60
Optional Performance:
4.4.1 Uniform Load Deflection per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 45.0 psf (positive) 0.60" See Note #2
@45.0psf(negative) 0.53"" See Note #2
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 67.5 psf(positive) 0.02" 0.163" max.
@67.5 psf(negative) 0.04" 0.163" max.
Test Snecimen #4: H-LC55* 36 x 72
Optional Performance:
4.4.1 Uniform Load Deflection per ASTM E 330-97
(MeaSurements reported were taken on the exterior meeting rail)
@ 55.0 psf(positive) 0.40" See Note #2
@ 55.0 psf(negative) 0.27" See Note #2
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 82.5 psf(positive) 0.06" 0.131" max.
@ 82.5 psf(negative) 0.02" 0.131" max.
05-30324.05
Page 8 of8
This report is reissued in the name of Alside Window Systems through written authorization of
Veka, Inc. to whom the original report was rendered. The original Veka, Inc. Report No. is
05-30324.01.
Detailed drawings, representative samples of the test specimen, and a copy of this report will be
retained by A TI for a period of four years. The above results were secured by using the
designated test methods and they indicate compliance with the performance requirements of the
above referenced specification. This report does not constitute certification of this product,
which may only be granted by the certification program administrator. This report may not be
reproduce except in full without the approval of Architectural Testing.
For ARCHITECTURAL TESTING, INC:
~~~
))22/
Steven M. Urich, P.E.
Seni;>r If"oject Engineer
2./18/" :1
Digitally signed by Lynn George
Lynn George
Project Manager
LG:baw
05-30324.05
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542
813-780-0020 FAX: 813-780-0021
DATE RECEIVED
1A~v
, .'
PHONE CONTACT FOR PERMITTING
.-..,
OWNER'S NAME GIJrR.'f COOf?BZ
JOB ADDRESS '] k {' j. ;2- (?I E j) /J1 0 Ai r /1 (/ tF
PHONE. 1/5, /,b V I'
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL ID #
WORK PROPSED: ONEW CONSTRUCTION
Os I GN
PROPOSED USE: OSGL FAMILY DWELLING
o COMMERC IAL
(OBTAIN FROM PROPERTY TAX NOTICE)
o ADDITION
o ALTERAT ION
[J REPAIR
o INSTALL
o MOVE
o DEMOLISH
OMULTI - FAMILY
o INDUSTRIAL
0# OF UNITS
OSWIMMING POOL
o MOBILE HOME
o OTHER
DESCRIPTION OF WORK
CJ RESTAURANT & HEALTH DEPARTMENT APPROVAL
t tv/tV D 0 u.J S c /~1?-1t.I r;: ~ () G( 0
BUILDING SIZE
SQUARE FOOTAGE
HEIGHT
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY !PRMS.
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. ~. ~~
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.. :5"2, fJ-.J) C:::..
PERMITS REQUESTED
o BUILDING
o ELECTRICAL
$
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
o FLORIDA POWER
o W.R.E.C.
o PLUMBING
b MECHANICAL
$
VALUATION OF MECHANCIAL INSTALlATION
o GAS
o ROOFING
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAO YES 0 NO
BUIWER ~ ~
SIGNATURE ~ ~ STATE CERT OR REGIST #
********** ~******************************************************
CONTRACTOR..... SECTION
o w-y\R.,(
COMPANY
ELECTRICIAN
COMPANY
SIGNATURE
STATE CERT OR REGIST #
******************************************************************
PLUMBER
COMPANY
SIGNATURE
STATE CERT OR REGIST #
MECHANICAL
******************************************************************
COMPANY
SIGNATURE
STATE CERT OR REGIST #
*****************************************************************
OTHER
COMPANY
SIGNATURE
STATE CERT OR REGIST #
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictionsN wh
may be more restrictive than City regulations. The undersigned assumes responsibility
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be requireL
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor SectionsN of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "E'lorida's Construction
lien Law - Homeowner's Protection GuideN prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "ownerN, I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "ownerN prior to commencement.
E. CONTRACTOR' S/OWNER' S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Enviromnentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.8. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "AN or "A,etc.N, it is
understood that a drainage plan addressing a "compensating volumeN will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENTN.
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _ day of
by
acknowledged
, 20_
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _day of
by
acknowledged
, 20_
(name of person acknowledged)
Owho is personally known to me, or
(name of person acknowledged)
[1ho is personally known to me, or
Owho has produced
(type
and whoO did Odid not
of identification)
take an oath.
Owho has produced
(type of identification)
and who Odid DUd not take an oath
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped