HomeMy WebLinkAbout04-3411
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
Permit Number: 3411
Permit Type: MECHANICAL
Class of Work: FIRE SUPPRESION SYS
Proposed Use: COMMERCIAL
Square Feet:
Est. Value:
Improv. Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
Address: 5709 6TH ST
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number:
1,250.00
9/29/2004
40.00
40.00
9/29/2004 Phone:
FIRE SUPPRESSION SYSTEM IN KITCHEN HOOD
Name: BEANS TOWN BEST
Address: 5709 6TH ST
ZEPHYRHILLS, FL. 33542
REINSPEcnON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each bip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
nWarning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances
NO OCCUPANCY BEFORE C.O.
~~
SIG A U PERMIT OFF I
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8TH St, Zephyrhi11s, FL 33542
813-780-0020 FAX: 813-780-0021
DATE RECE IVED
qlttl!pt!
,
PHONE CONTACT FOR PERMITTING ~J S -9/{c' ?t/c,CJ
JOB ADDRESS
~f1KTOWlJ ~~
~J~C1 \;~ f:;T
PHONE
OWNER'S NAME
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL ID #
(OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPSED: (JNEW CONSTRUCTION
(J ADDITION
(J ALTERAT ION
(J REPAIR
~ INSTALL
(J SIGN
(J MOVE
(J DEMOLISH
PROPOSED USE: (JSGL FAMILY DWELLING
(J COMMERCIAL
(JMULTI-FAMILY
(J INDUSTRIAL
(J# OF UNITS
(J SWIMMING POOL
(J MOBILE HOME
(J OTHER
c=J RESTAURANT & HEALTH DEPARTMENT APPROVAL
DESCRIPTION OF WORK J:,&-t ..,1 "'1'v' <;'1IW"9 &",1; "J _S\\~J..e!VI It-- r\) 1 ~ h ~
(J MECHANICAL
BUILDING SIZE SQUARE FOOTAGE HEIGHT
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) S~~~~~~~
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FO~S'. ' j ~~~ /
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. //t<oJtNf ~ /'
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTli ~-~o:~;::::.- '\
PERMITS REQUESTED ~/ () r-/ ~ /
JZ5:P, ~ VALDATION OF TOTAL CONSTRUCTION 4#0 / .
AMP SERVICE (J Progress Energy (J ~/
/' ~to~
VALUATION OF MECHANCIAL INSTALLATION ~'A/ ~ '
, d ~ _ '. ~ (),Uv.
,,' ~ ~/
(J BU,ILDING
$
(J ELECTRICAL
(J PLUMBING
$
(J GAS
o ROOFING
~SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE
BUILDER
COMPANY
SIGNATURE
STATE CERT
******************************************************
ELECTRICIAN
COMPANY
SIGNATURE
STATE CERT
****************************************************
PLUMBER
COMPANY
SIGNATURE
STATE CERT OR REG ST #
************************************************** ***************
MECHANICAL
COMPANY
OTHER
,~-r ~~,
~
COMPANY f;.v- h qh~ ~n e-
STATE CERT OR REGIST it crJJ3.$"O(O~n I )ql17
SIGNATURE
STATE CERT OR RE 1ST it
*****************************************************************
SIGNATURE
A. NOTI~E OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by iaw, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign po~tions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's ,Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or a?andoned,for ~a
period of six months after the time the work is commenced. One 90 d~y extens10n of t1me
may be allowed for the permit with fee charge of $15.00. The extens10n shall b~ requeste~
in writing to 'the Building Official. An approved inspection must be logged dur1ng each S1X
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
acknowledged
, 2~
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____day of
by
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _ day of
by
acknowledged
, 20_
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
C1ho is personally known to me, or
o who has produced
(type of identification)
and whoD did Ddid not take an oath.
Dwho has produced
(type of identification)
and who Ddid [)did not take an oath
Signature of person taking acknowledgment
Signature of person taking acknowledgement
Name typed, printed or stamped
Name typed, printed or stamped
BEANTOWN CAFE
5709 6th St.
Zephyrhills, FL
Fire Suppression System For Commercial Hood
Fire Fighter Inc.
P.O. Box 888
Land O'Lakes, FL 34639
813-996-6469
/ t/t3()o (l",,cJ/~ /;t/rP'd <?6 ,
- ;tr()JfJt (,/;/ tmf~1L ui5(/aJ /P!(//~
IJ-JJ;HcndJ 1tJt! 'f'~ r
- . // / ~c pj J)JI;tr cPiflc. / --- ~
_ }:;k()J1 -44 r{) (/r.urf f/# hlM'- hf'" -
Cylinders
Cylinders
Range Guard systems have available five different
cylinder sizes: RG-1.25G (1.25 gallon 14.7LII. RG-
2.5G (2.5 gallons 19.5LlI. RG-4GT 14 gallon tall U5
LII. RG-4GS (4 gallon short (15LlI and RG.6G 16
gallon 122.7LIl. !
Each cylinder Is pressurized with nitrogen or air to
175 pslg (1205 kPal. at 70"F 121"CI.
Note: II i. recommended that cylinders be stored
uprighL
m
I
RG-4GT
4 GallonTaJI
(15L)
RG-6G
6 Gallon
(22.7L)
RG-4GS
4 Gallon Short
(15L)
RG-2.5G
2.5 Gallon
(9.5L)
RG-1.25G
1.25 Gallon
(4.7L)
1"tgure2-1. c,uadel'
Table 2-1. c,uadel'SpecUlcation
Cylinder
Size
Part
No.
Charged
Weight
Lbs
Height to Center
Diameter of Discharge Port
Inches Inches
Ovel'llll
Height
Inches
Ovel'llll Height With Overall Height
Mech, Elec or Tandem With Pressure Op
Control Head Control Head
Inches Inches
B13XD1
28.5
14
15038
21
1~4
22-3otl
.3cm
~
1.7an
Sll2
1!I2.7an\
~5e
(93 an)
Brackets
Brackets
~A ---I
I
"!
.
.
9-
MOUNTING BRACKET
FIGURE 3c
. Tnl.2c
Plirt CyIIndw Dimension Dimension Dimension DIat8nce Between Dlstanc. Between
No. - A 8 C VertiC81 HoI.s H0rlzontaI HoI..
I7Gl 5 QuIll 1-311I' 3-114' l-M1
. 4.71..) Semi eml 14.1 ani
17263 2-1/2 GIllan 2-1/2" 3-112"~'"
.51.. /6.4 eml .9 em - 12 ani
17414 .. Gdan-l 2.1/2" 3-112"
(151..1 (6.4 eml .9eml
97415 " Z' 3-112"
(151..) (Sanl (8.9 eml ...: -
Cylinder and Valve Assembly
so .. 10 II " II 10 100 110 120
~ ~ ~ ~ ~ ~ ~ ~ ~ ~
Temperature of (Oe)
CYLINDER GAUGE PRESSURE
200
(1371 kPa)
-
ca 110
Do. (1309 kPa)
~
-
C) 110
in (1~ kPa)
Do. 170
! (1171 kPa)
=
II) 110
f (1102 kPal
Do.
150
(1033 kPa)
o
(-11)
11
(-12)
21
(-7)
Figure 2-2. Cylinder Pressure
If the ambient temperature Is not 70"- (21ee),
the pressure of the cyllnder wm vary In accordance
With Figure 2-2. For example. If' a cyI1nder was stored
In an ambient temperature ofcrF (-ISee), the pressure
SPRING RETAINER
SPRING
O-RING
VAlVE STEM
IONDED SEAL
Figure 2-3. Cylinder Valve Assembly
(PIN B120009j
gauge should read 150 pslg (l033 kPa,), which Is the
lower edge of the green zone on the gauge. Conversely,
at 12o-F (4!rC) ambient, the pressure gage should read
193 pslg (1330 kPa,), the upper edge of the green zone
on the gauge.
[FLANGE PLATE
NUT [ADAPTER
.......1..... o-RING
~~...Q.. r SHIPPING
ANTI-RECOIl I?(, .r CAP
CAP "
BOLT ,/'
1111-11 X 1.00 LG --.."
CYUNDER-AND.
~ VALVE ASSEMBLY
Figure 2-4, Discharge Adapter Kit
Installation (PIN 844908)
Piping Requirements
Equivalent Length
Equivalent feet is defined u the actual measured length of
discharge line plus the equivalent length for each fining In the
line as obtained from the data given in Table 9d or table lad.
. T.ble 9d Pipe Fitting EquiVIIlent Length
EquivIIInt LIngItI
PIpe FIttIngs
. T.ble 1 Dd Tubing Fitting Equiv.lent Length
Equivalent lAngth
3110 . 5/10 I 7/10 I ,.
1.0 c:m) 1(1.1 c:m) (2.2 c:m)! (2.5 em)
1.5 fl I 2.5 fl 4.0 fl I 4.5 It.
(.41 m) k.78 m) 1.22 m)f1.37 m)
O.Sfl 1.0fl 1.0fl I 1.0 It.
(.15 m) .30 m) (.30 m) (.30 m)
0.8 fl 1.3 fl 2.0 ft. 2.3 fl
.24 m) .40 m) .61 m) .70 ml
0.5 fl 0.5 fl 0.5 fl 0.5 It.
.15m) .15m .15m) .15m)
1.5 fl U fl I 4.0 fl 4.5 fl
(.46 m) .76 m) k1.2 m) 1.37 m)
o.sfl~O.5fl 1.0fl 1.0ft.
(.15 m) (5 m) .30 m) (.30 m)
".. / 3/1. I 1120 I 314. ,.
(.I CIIl) (1J1_~1.3 CIIl) (1.1_~ (2.5 em)
Tube FItIings
90. Elbow
..so ElboW
T.. (Cullet)
T.. (Run)
EquiqIent feet Is ..........trarn the cylinder
(1he ...... ~ in. manifold) to the most
..-note nozzle. Equivalent feet II aIIo mea.
and betwMn 1M two maG ~ nozzIea.
EquivIIIent feet Is IMMUM only along that
branch with the most equivalent fMt. Table
1 1d Iiats the maximum equivalent IengIhs for
MCh cylinder size.
. T.ble 11 d
Cylinder
...
I!quMIem FL
from
Cylinder to Moat
Rem0t8 Name
10'" Elbow
10'" Bend
450 Elbow
450 Bend
T.. (Outlet)
Tee (Run)
. EumpIe ,
"
~
/
10" a1.
Equivalent FL
Between
Moat Remote
NozzI..
"The rnaximuma listed in Table 11d app/y to manifold systems as welles
lingle cylinder 8ptems.
'2"
.3m
'I
~
10" a1.
1Jr Pipe
(1.3 em)
Figured 49d
Eauiv81ent Feet
(from Table 9d)
goo 112" Bbow: 1.5 eq. ft.
go" 112" Bbow; 1.5 eq. ft.
1.0 It of 1/2. PiDe
4.0 eq. tt. TOTAL
Vent Plug
All systems must have . vent plug in the discharge piping.
The vent plug should be dose to the cylinder to get maximum
pressure on system IICtUatJon. "must also face up or out.
Facing it down will make the vent inoperative.
. Example 1
VENT PWG
11984
FIGURE 57d
SUPPLY
PIPE
. Eumple 2
UNION
FIGURE 58d
SUPPLY
PIPE
1d
VENT PWG
11984
Fusible links and Detection
Detector
'The detector consists of aplateclsteelbradcet, '.314" (29.8
em) long, a lis1ec1 fusible link. 2 cable crimps ancl2 "S" Hooks
to connect the fusible link to the det8CbOn system cable.
14
11-31."
.... ....,
~I
1r EMT
CONNECTOR .
LOCKNUT '\ A (NOT SUPPLIED)
...; ~ "';~L"'_.,
.... .., ;=:..,.. ...............
-r: ..H_'-- .,"'... ~
1ft." CA8~ TO
ANCmtEJl DErECTOR
OR REMan
MANUAL CONmOL
\=-
CONNECTOR
DETECTOR 97024
FIGURE 11c
7,.. (2.2 em)
R.tlng
Part
No.
Maximum
Ambient
Tempermure
.00- (204") 57643 375" F (191" C)
soo- (260") 57644 475" F (246. C)
a.o.d rating of both IinIca il2SOI (113.4 kg).
GLASS BULB
(QUAR1Z0ID) LINk
FIGURE 1Zc
DATE-(SHOWN AS .XX.
300" F (14r C) maximum -.nblent tempel'8ture.
Mln 3 lb.. (1.4 kg) - Max. 45 lb.. (20.4 kg) r8ted
3600 (18" C) FUSIBLE UNK 96903
FIGURE 13c
Mechanical Gas Valve
Mechanical Gas Valves
Mechanical (spring loaded) gas valves can be closed upon
system actuation by using either a 1/16- (.2 ern) diameter cable
anached to the predrilled hole on the discharge lever of the
Mechanical Control Box (see example 1) or a 1116- (.2 an)
diameter cable attached to a pneumatic release installed on a
12- (30.5 em) riser, anywhere on the discharge pipe line (see
example 2). The maximum lICtUation cable length is 50 feet
(15.2 m), with . maximum of 25 comer pulleys if a mechanical
control box is UHCI or 16 comer pulleys if an A+ control box is
used to actuate the gas valve.
. Example 2
PNEUIIAlIC REL!ASE
IDIII'ED HORIZON1'AU.Y
..-
1
,.. JlIIE NI'PLE
(.I ClIlI
t=
12" MAX
NIB
(as CIII/
!
.....
(10__10_1
JUNCTICIN BOX
........-0 BY
cmtBlS)
~ILOCIC
.&,
1--'CU anJ
t
lDIUT
~kOl'l
VI" lilT (1.1e.!
CONaUIT
. Example 1
CMIP ""
CONNECTOR
Z" X C. JUNCTION
(I an X 1D ml
lOX. SUPPUED
BY 011IEM
wc- (1.1 CIII)
PI JAIl
NUT
FIGURE 55d
FIGURE SId
Remote Pull Station
Remote Manual Controls
There are two types of Surf8ced Mounted Remote Manual
Controlaavailabl.. End-of-line(FlgUre 14c) and In-Un. (Figure
Ix). Each is used as . means to actuatettte system manually
from . remote location. lbis is KCOrnpIished by removing the
pull pin. releasing the tension in the detection cable. .Iowing
the Control H..d to aclivate1he cylinder.
If an End-of-Une Remole Manual Control is nol applicable.
II can be converI1td to an In-Une Remole Manua' Conlrol by
usmg an In-Line Kit. Refer to page 1-3 of IhlS manual. An In-
I.i'le Kit uses a BFPI approved Tee Pulley and Comer Pulley
Beanng (see Figure Ix) to modify Ihe End-ol-une Remole
Manual Control.
Refer to page 1-3 of this manual for installallon IImltallons.
i i
. -....
:,- : ~-....... -a IA.-
4IUILIT _
--
--
e
.. CAlI
CII' PI"
IW&L ...
.... CI&Il
---
....-.-
.
.\J.--<<
..
~-
y...-r
-
SUrface Mounted End-of-LJne Remobt ......1 Control. 97463
FIGURE 14C
"/1".-
-.r_
"'c.a.~'"
."'-
...~-
,r DT call IC'fDtI
PIN 97464
SURFACE MOUNTED REMOTE MANUAL CONTROL IN-UNE CONFIGURATION
IN-UNE KIT, 97464
FIGURE 15c
-
-c.a.--
-~-
&au_._
~..
"lr__
r
"'
r
Placement in Duct
"
\..
Duct Protection
The ADP nozzle. PIN B 1200 II. Is used for protec-
tion of the exhaust ductwork.
The duct cross secllon can be any shape (t.e..
round. square. or rectangular) and the duct Itself can
be of unllmlted length. In accordance with NFPA 96.
the exhaust fan should be left running at the Ume of
system discharge. A damper. if present. should be left
open at system discharge. However. If the damper Is
closed. the system designer must Insure that the duct
nozzle discharge ts not impeded by the closed damper.
~
Protection of Ducts 0 to 50 inches
perimeter
One ADP nozzle. PIN BI2001l. Is required for
protection of a duct with a perimeter up to 50 Inches.
(See Figure AD-41. Length of duct Is unlimited.
The nozzle Is located at the geometric center of the
cross-sectional area that It Is protecUng. and Is located
In the duct within six Inches of the entrance.
Note: All Range Guard systems are listed by UL for
use with the exheust fen either on or off when
the system is discharged.
" .
. .
DUCT
~
110OO
DUCT PERIMETER UP TO AND INCLUDING 50 INCHES
11.78 inches maxilTlll1l diagonal
12.~tE
MAX. I
...:i.....
SQUARE DUCT
~
c.
: r- AOP NOZZLE
:1 I ..!
i ~2mm)
DUCT ENTRANCE
t'~~j
rn
I+- -S"-+I
T rn 11.78 inches maximum lflll!lOl18l
"A"
..:!...
RECTANGULAR DUCT
2 "A' + 2 "B"" &SIN
ROUND DUCT
Cl OF VERTICAL DUCT
J
~ AIM POINT
tit;
I
I .
AOP NOZZLE " .
-. ~ I Cl OF HORIZONTAL DUCT
I
VERTICAUHORIZONTAL DUCT
2 to 4 inches
Nozzle tip 10 duct hip
"-
~
Placement in Plenum
Designing for Plenum Protection
A aingle AOP nazzIe wiI protect a lingle filter bank planum with
the following maximum dimensions:
. Faat (1.1 m)
. Feat (1.2 m)
. (1.8 m) FHt Long -
ZD Inctlel (51 em) Wide
Aaingla ADP nozmwill proIad aVr"'r bank planum wilh the
following dimenSionS:
Plenum ~ngIh
Plenum Width
FIlter Area
3 FHt (.9 m)
.. Feet (1.2 ml
3 Feat (.9 m) Lcmg -
.to InctIea (102 em) WIde
~~1hen::::===:'V'lIIIer
Plenum lAngIh 1D FHt (3.0 m)
Plenum WIdlh .. Feat (1.2 m)
FlWr Area 10 Feet (3.0 m) Long -
40 InchH (102 em) WicIa
PIerun LAngttI
Plenum Width
FIlter Area
NOTE: 40- (102 em) WIDE FILTER AREA IS MADE UP
OF TWO FILTERS WHICH 80TH HAVE AN EXPOSED
FILTER SURFACE OF 20- (51 an). ntts DOES NOT
INCWDE 'THE FLTER PRAllE.
-..-.~-
When no filters are presenl. the nozzle proteding the
plenum is UAd to discharge Katbaloye on the underSide at
the hood. 'n this cae. the hood may not exceed alenglh oC
61L (1.1 m) for 1he ADP nozzle and 10 ft. (3.0 m) tor the
plenum nozzle. The hood shall not exceed a widltl crt 6 fL (1.8
m) for eilhar nozzle.
A lingle "'r bank planum with a length of 61l (1.8 m) or
... may be praI8C;1ed by one ADP nozzle. A 'V' fiIIIr bank
planum with . IlIngth of 3 ft. (.9 m) or lea may .. be
.,A~ by one ADP nozzle. A plenum with either a single
_bank or 'V liter bank and a length of lOll (3.0m)or...
may be proteclMt by one plenum nozzle. Either nozzle shall
bemcm.d at_and aflhe plenum. Langer~ maybe
IIimiIMy praIK1R wiIIl a aingie loOP nozzle being ...a tar
-=h3or61L (.9 or 1.8m) of plenum length (dependingonlhe
tp af ftbr a.nk) Md uch '0 Il (3.0 m) of pienum IangIh
for....... nozzles.
ADP and plenum nozzles mBY be used in IIfV cantina-
Iians (see FIgure , 9d). Multiples may be instaIed In pan at
the midpoint of 1he plenum with their dlscharg8s dncIed 11
the ends of the plenum or installed . each end of 1he pIerUn
wiIh 1he disdwgM dnctIId . the midpoint.
ADP 8nd plenum rmzt.s must be cenIrdy IcaIId in lie
pIIIun (.... figtn 32d) wIIh IhBir diIcharge direcIed aIaIlg
1he Itrigth at the plenum. In no case. however. shill ..
horizolltal CWIler Ine of the nozzles be (ocated morw ttIM 15
(38 em) incMa from the inside filler surface.
...,. -..... --
~ 1....7~.IB
B ~"I'(1~.1 ~
t> =-..
~ ~ ~"1r(UJ ~
t> ...c::I 12' (3J IlII
n-p,'" r e>1
13'
r
~
4 tl'(UIII)
"""'.........-.\ ..
l'n.(u~"I~
~ <t> I ,8'(lIIl) . E
~ <11III fI""'1L'....'.I.. ~
EXMoA.ES OF TYPICAL NOZZLE P\.ACEMENl'S USED TO PROTECT PLENUMS OF VARIOUS LENGTHS ,
;:~_\~ A::: ~~-7~;:_:-
~13I_1 NO~~WlTHINPLENUM ~ Mca_,
-~ ~ --......
_La......~ _Il FIGURE 2Dd -v- ~L""" ...NIl
~
<>
~
J
Placement Over Range
IWiGE
One 'R' nozzle wi8 protect one four burner range with a maximum hazard area of 2S" x 2S- (71 em x 71 cml.
The nozzle is to be Iocaled direcdy over the midpoint of Ihe hazard area and anywhere within fhe area of a circle generated
by a g- (23 em) radius about the midpoint. The noZZle shall not be more than 42"(107 em) nor less than 20"(51 cml from
the midpoInt of the hazard area. aimed at the midpoint. (See figure 27d) NOTE: SHAPE OF BURNER NOT IMPORTANT
1r DIA. (. CIlII
-1U"~1
A.... NlJZZLE MAY at
ux:A1ED AIIYWItIJlI WI11IN
111I IIIAIIID MEA.
POUR BURNER RANGE
FIGURE 27d
TWO BURNER AIM POINT
CENTER OF HAZARD
FIGURE 29d
. .
..
1.- EIIA.C'" em)
1U"~cm)1
A .... NOZZLE MAY n
LOCATeD ANYWHERE
WITHIN TME SHAOI!EI AM&.
SlNGLI!: BURNeI RANGE
Speci8I care is to be.... when .nning the 'R' nozzle over a single bumer range. The aiming point is to be located r (1S em)
from the c:enI8r GIllie burner. The nozzle plKement shall fall within a cylindrical area generated by a 9" (23 em) radiuS about
the Uning point. The nozzI8 must be pIKad no more than 42" (107 ern) nor less than 20- (51 ern) above the haZard areL
(See figure 3Dd)
. ....
.. ..
1""...___
11111I_ CIIIlIIUIE
SINGLE BURNER RANGE
FIGURE 30d
" ,
Placement Over Griddle
GRIDDLE - FLAT COOKING SURFACE
One AOP nozzle will prolect one griddle I.with or without
raISed ribs) with a maximum hazard area 0130. )( 42" (76
cm x 107 cm). The nozzle is located at 8ft\' point on the
perimeter of the appliance and amad at. pamr 3" (7.6
em) from the midpomt of the hazard area. It shall not be
more Ihan 48" (122 cm) nor less than 13"(33 em) above Ihe
edge of the appliance perimeter. PosiIionina 'he nozzle
directlv over the aDDliance is no' accl!Dlable (See figure
ad.)
IWl. (t22 em)
~..-......
F~""::~'"
--
'SO_CD_
_".rv". --...
......--
Ilr YAX
(tD7 eml
GRIDDLE - FLAT COOKING SURFACE
AGURE lei
A PL!NUllIICIZZLE MY. LOCATED
ANYWHERE.".1llE GRm
"1m em)
IIAX
DUGONAL MEASUREMENT
IlROII AlII POINT
.. (114 cm)
IIAX
All POINT:
.:JPOINT OF HAZARD AREA
CENTtRED ON DMDER
Oft" BOARD
~
1." MAl
(36cml
SPUTVAT DEEP FAT FRYER
FIGURE 9d
Placement Over Fryer
~
One 'R' nozzle will protect one four bumer range wilh a maximum hazard area 0128. x 28" (71 em x 71 em).
The noZZle IS 10 be located directly over the midpoinl of the hazard area and anywhere wilhin the area of a eircle generaled
by a g" (23 em) rIIdius about the midpoinl The noZZle shall not be more lha" 42" (107 eml nor less than 20. (51 eml from
the midpoint of the hazard ant., aimed at the midpoint. (See ligure 27dl NOTE: SHAPE OF BURNER NOT IMPORTANT
.... .....
.... ....
..... ....
... ....
..... .. ..
A.... NOZZLE IlAV BE
LClCA '\'ED AHYWttERE WlTMIN
1ME IIWlP AAEA.
..
.. .
(
SPLIT VAT DEEP FAT FRYER
One: F nozzle: or Plenum Dozzle: wtll protect a Split
Vat Deep Fat Fryer wtth a split vat hazard area maxi-
mum of 14" x IS" (36 em x 38 em) wtthout drip board
and 14" x 21" (36 em x 53 em) wtth a drip board. The
nozzle is located at an angle of 45 degrces or more
from the horizontal. It shall not be more than 45"
(114 em) nor less than 2T (69 em) from the top of the
appliance and aimed at the midpoint of the hazard
area. The nozzle can be outside the perimeter of the
appliance. (Hazard Area 14" x IS" (36 em x 38 em) -
See figure 3-9)
AN F OR PLENUM NOZZLE MAY BE LOCATED
ANYWHERE WITHIN THE GRID
DIAGONAl. FROM
AIM POINT
..s"
(114 em)
MAX-
AIM POINT:
MIDPOINT OF HAZARD
CENTERED ON DMDER
~ 21M (114 em)
INTERIOR
OVERAll
\
14~~) ~I
Figure 3-9. SplitVat Deep Fat Fryer
Nozzle Summary
Table AD-1. Nozzle Summary
Perimeter Diameter Nozzle /
Hazard Max. Max. length Row No.
length Width Nozzle /
Hazard Max. Max. Filters Row No.
Duel
Duel
Plenum
so- (165.1 em)
100- (254 em) .
10' (3.0 m)
15.91- (39cm)
23.S- (IO.5cm)
4' (1.2 m)
Unlimited.
Unlimited
ADP /1
Z-ADP/2
.V- Bank or
Single
ADP /1
Hazard Size Nozzle Height Notes NoZZlel
Hazard Inche~cm Inche~cm Inche~cm Row
Four-BumerRlnge
All Cooking Surface -Griddle
Single Val Deep Fal Fryer (Drip Boards 1 tI 6 (2.5 1018))
Single Vat Deep Fat Fryer (Drip Boards < 1" l2.5D
SpIil Val Deep Fat Fryer
Split Vat Deep Fat Fryer (Low PIOIinity)
Woks
Upright Bn:iIeIl (Salamanders)
Closed Top OIain BroiIeIl
Open Top ChIin Broilers
Pwnice Rock (lava. Ceramic) Q\arbraiIer
NalurIlIMesquft 0Iarc0aI CharbroIer
BeClric Clwbllliler (Open Grid)
Gas Radiant OIaIbroiler
Mesquile Charbroiler(Chips. Wood. Logs)
NaturaJ/Mesqlite 0IIn:0aI ChIrbnliIer
1iII Skillel and Bflising Pan
28 X28 (71 171)
.t2 X 30 (107 I 76)
18X 18 ("6 x 46)
24 12" (61 161)
14 I 15(36138)
14 x 15 (361 38)
14f028(3610 71)Dia.
3 to 8 (8 fo 20) Deep
30.25 X 3.t (77 I 86)
28 X 29 (711 74)
28X29(71x7")
22X 23 (56 158)
24X 24 (6h 61)
24X21 (61 153)
24 X 21(611 53)
30 X 24 (761 61)
3D X 24 (761 61)
24 I 2.. (61 161)
within 9(23) rad.
afmid point.
3(7.6)OfIsel
45" 10 90"
wilhin perimeter
45"1090"
lIIiIhi'Iperimeler
within 2(5)
afnidpoint. GRW 11
lop" (10)0Ibroaercomp. ADP/1
See 3-12 ADP I I
See 3-12. 2 Noules ADP 11 ...
45"10 SO";
21.1yers 01 rock Ff2
45"1090"; ADP/1
II (16) Charcoal depth
45" to 90" GRW 11
45"1090" GRW I I
45"1090";
10 (25) Fuel depth OM I 3
45"1090";
10(25) Fueldeplh OM 13
27.5 II (7D em) 10 46 in (117 em)
wiIhi1perin111r
201042(5210107)
13to.t8 (3310122)
271045(691011")
27.5 (7D) to 46" (117)
27 (69) 10 45(117)
1 (41)t027(69)
351056 (89 10 142)
See 3-12
..3-12
24(61)1041(122)
24(61)1041(122)
24 (61) \o.t8 (122)
24(61)\041(122)
24(61)1048(122)
24(61)1o.t8(122)
RI1
ADP/1
F12
Ff2
F12
ADP/,
F/2
Nozzle Nozzle Part
Identification No. Flow No.
ADP (Appliance-Duet-Plenum)
F (Fryer)
GRW (Gas Racr.."t-Wok)
R (Range)
DM (Mesquite)
8120011
8120012
8120013
8120014
8120015
1
2
1
1
3
~
o
I-t
UJ
UJ
~
~
~
~
b
UJ
~
~
I-t
~
~ 0\
U M
\0
C . ~
~ t-4 -C M 0\ l'-..
e ~ a: 00 ~~ \0 0\
~ 00 ~ ......
.... i..: wOOCU~\O c
ell rI:1n -8 I- ><.5 rI:1n..Q C
- C
~:E u %oo..cuO\ c;
\:5 ~ ~~<~O\
~ 0\ !>, ..:: '"
s::: t-40o~ --- lY)
0...1:: c3 M ......
~ 0.. II. M n ...... C
cu Wp..;MO 00
i3 N - '-"
s::: a: ~-C
~ 'l=I:
1:: t-4 C U
..... II. j ~
~
;::s CQ
.s
""
~
'0
o
o
::I:
00
Cl)
~
:>
'"
C':l
C)
-r-------D
I
I
I
I
I
I
I
I
I
I
I
I-<
~
~
......
I
I
I
I
~
I
I
I
~
I
I
Cl)
:g
'1=:
C)
\0
("l
N
N
...~
'll.l'
:::~. ...
Zi
......~.
..~.
i
.::It:.
....-<'
.~
.~ O""l.
.- ........~....-=.wo.5
,,/ i~i
.~...~....... Atid
.~.. == ->:z:....-=.:..
~.i;.........:e.~. g;
.... ... _... l'"l.~..
e =-!03= ..;l.@
~ ~ . ,g........ ....~.Q. 8.........
~ - ~ ->-~>
1iio41oo1i,.;ll.l~
ell .... Aloo.::!=.-c
.... QO ;.:Il WOll.lCli......ll.l
~c!l~...A"Cl~t;
.~.II~~i.l..~.
C'I'.~ .ll.l'.'S.'.=L=..o{~
1i'<~:g5~.;;S:
O;=ll.l\:ii~~I.~..
~~~I~~l~
'=.Iiio4. ..... -.:l.T_'..........~... ..
.~... ......~. .....,.......""-<.rn
de . e . e ed e. e.