HomeMy WebLinkAbout04-3571
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
3571
Permit Number: 3571 Issued: 11/09/2004
Permit Type: GENERAL BUILDING PERMIT
Class of Work: 434-ADD/AL T RESIDENTIAL
Proposed Use: MOBILE HOME PARK
Sq. Feet: Est, Value:
Cost: 500.00 Total Fees:
Amount Paid: 90.00 Date Paid:
Address: 38633 GRANGER LN
ZEPHYRHILLS, FL.
Township: Range:
Lot(s): Block: Section:
Book: Page:
Subdivision: VILLAGE GROVE
Parcel Number:
Name: HOMEOWNE
Addr:
Phone: Lie: Phone:
Work Desc: REPLACE SKIN ON HOME AND ROOF OVER
ARDELLA NOVINGE
38633 GRANGER LN
ZEPHYRHILLS, FL. 33542
. ~j. I
(, ~ (2 !3jOY'
1
DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB
DUCTS INSULATED LINTEL PRE-METER WATER
SHEATHING FRAME MISC SEWER
MISC INSULATION WALL MISC MISC.
MISC. INSULATION CEILING MISC. MISC.
MISC. DRIVEWAY MISC. MISC.
REINSPEcnON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
NO OCCUPANCY BEFORE C.O.
1~'rJ~~ ..R-.
CONTRACTORS SIGNA'tURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Type
Placement
To
Fastener
Size
120 mph
Zone Zone
1 2 & 3
Wind Speed
135 mph
Zone
2 & 3
Zone
1
150 mph
Zone
2 & 3
Zone
1
Weco
Screw
5.8"' Thick #9 x 1.1/2" 30 23 30 13 28 15
,Dlywood
12 Ga. to 16 Ga. #12.14 x 1" 30 19 29 15 2.:i 12
TCP3
18 Ga. to 20 Ga, #1/4-14 x 7/8" 30 20 30 1 ~ 'i~ 13
TCP1 .0 Co]
22 Ga to 24 Ga, # 1/4,14 x 7/8" 30 20 30 lc r,.- 13
TCP1 ~J
26 Ga. # 1/4 -14 x 7! 8" 23 12 18 10 : ,J 8
TCP1
Metal
Screw
DATE
~~ ,~t .-, '>,,'....:1
c
";a,::C'I-"; 2"".. "'.~'",. , '~','-.
;";~:":"'" "''''
,~id~:
rE: T~,2 :as:ener 5:.2'::l:g in the trim area for 'Jilferent zon~s
-4.
Zone 2
a
~ +1 rt
:--- -------'\-------------------r+ a
~ - - - . - - - - - - - - - - - - -,r=- - R.!d.9: - - - - - . :. a
a
t - - - - - - - - - - - - - - -. - - - - - - - - - - -.. _;L..
:\ Zone 1 ,
j \ 1
' ' I
L _\_ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ ~ _ _ _ _ _ _ _ _ ,_
L Ea':e
G2tie
I
Ii
I;f
Hi
:1
11
:/t
'l,If
i \
\
II
"
II
1.
r
\1
Ii"
I',
II
Ii
II':
I, !
\
Zone 3
Note: DimenSion (a) 's defined as 10% of the minimum width at the building
or 4'Jo, cl (,le mear height 01 the root, whlche'Jer is smaller, however, (a)
cannot be less than either 4% of the minimum width of the building or 3 feet,
MAXIMUM AUOWABLE SPAN TABLES
I T!I<: )eCIJI)II pi"uperfJes urlhe' p~lIld, ",,'e ":tIcIlI~Il"U b:J.'<:d on AI.';! l0'j':i
,) The ~lil()"'abk Sp:lI1 C:\Jclll:lIjOIl is iJ'berl UIl palld 'l1"<:llglh 'lIld b.\(<:ne~\ Ctp;tCil: ill diU,"':::' "::.':':11", t.., [llIcc
Or !!IUr" 'pall condit.iu".,. The diU"i"<:1l1 :;lllht.I~l[eS ,hUllld be designed hv 'Jchns 10 ,can'. I.,,,ds ':::I)'""d "" {lic
p.\llels alld :;lllhll":lI<:.S,
j, The t:"lell<:r flllllulll:lIlCl rltrllov<:r load., ;u'e b:J.sed Ollll:;illg \>,ood sere',,', 1,:;<j_lij) ,,,1<' l;iii).!~ T':l, ''i)I).I<;)
:\lld 1#1~,14); Llf)(<:k.s (#1/4 x 14) uacashens.
4, L:,,, Oil Siuelaps #14 x 7/,")" L-tflll.'k.s :10" OC
:; The panel Inaxil1\lll1l 'flans h:1\'e heel\ reslJ;Cled (0 :10",
... ~
Installation Instructions for MasterRib"~
Stora:~e
If metal is not to be used immediately, store inside in a well ventilated..d1y10cation.Condensation or other moisture can form between the
sheets during storage causing water stains or white rust which detract from the appearance of the product and may affect the product's useful
life. TrapJled moisture between sheets of oainted metal can cause white rust to form underneath the oaint. This can cause the paint to
flake 0" the paneLimmediatelv or severai vears later. To prevent white rust and staining, break the shipping bands on the material. Store
the material on end or on an incline ofafleast8"withasupporting board underneath to prevent sagging. Fan the sheets slightly at the bottom
to allow for air circulation. Keep the sheets off of the ground with an insulator such as wood. Any outdoor storage is atthe customer's own
risk. If outdoor storage cannot be avoided, protect the metal using a canvas cover or waterproof paper. Never cover the metal with plastic as
this will cause condensation to form.
Some SafetvPrecautions
Always wear heavy gloves when working with steel panels to avoid cuts from sharp edges. When cutting or drilling steel panels, always wear
safety glasses and sweep off any metal shavings immediately to prevent eye injury from flying metal fragments.
If you must walk on a metalroof,take great care. Metal panels can become slippery, so always wear shoes with non-slip soles. Avoid working
on metal roofsduringwetconditions when the panels can become extremely slippery. Walking or standing on a metal roof which does not have
a plywood or other deck beneath iUs not recommended. However, if you must do so, always walk on the purlins, never between. Do not for
any reason walk on a roof made of material less thick than 29 gauge.
General Installation ,Information
Insure that the structure is square and true before beginning panel installation. If the structure is not square, the panels will not properly seal
at the side laps.
Green or damp lumber is not recommended. Moisture released from the damp lumber may damage the metal panels. Nails installed in green
or damp lumber may back out.
The prevention of steel debris staining is the responsibility of the installer. The recommended tools for on site cutting are profile shears, hand
shears, or electric nibblers. Friction saws and abrasive discs should not be used to cut panels.
Remove any loose metal shavings left on roof surface immediately to prevent corrosion. Afterinstalling roof, remove any debris such as leaves
or dirt to prevent moisture from getting trapped on panels. P J REVIEWED
Fastenin~ DATE
If you wish to predrill fastener holes, use a cover sheet to prevent hot shavings from sticking to ~~~~NG EPT APPROVE
Screws -Forbest results use a I -112" double washeredwood screw in the flat of the panel as shown in the illustration below. Fasteners shou e
applied at everypurlin. Drive the fastener so that the washer is compressed securely ,against the metal. Do not over drive the fastener
as this will forma dimple that can collect water and cause leakage. Do not leave any loose fasteners that have missed the purlin. Use
a #14 stitch screw or caulk to fill the hole.
Nails - Ifthe panels are nailed, use 1':3/4" ring-shanked neoprenewashered nails. Nail into the crown of the major ribs of the panel as
illustrated below, (See Figure #2 below). NOTE: If rigid insulation is used directly underthe panel, the fastener length needs
to
be increased to allow a minimum of 1" penetration into the wood. General installation instructions listed above for screws also
apply to nails. Do not apply nails into flat area of panel.
Fil:ure #l-FasteningPatterns for MasterRibilY
RECOMMENDED FASTENING PATTERN FOR 1-1/2" SCREWS
~-~~-~
SCREW FASTENERS -EAVE, RIDGE, & ENDLAPS
~ - -r^ ~ ~-------tA-
SCREW FASTENERS - INTERMEDIATE SUPPORTS
Fil:ure #2 - (Nails only)
UNDERDRIVEN CORRECT OVER DRIVEN
..t1'..r1'x ./]\.
Fieure #3
A-
FASTENING PATTERN FOR 1-3/4" NAILS
A__A_~A_
~~
7
T
3/4"
t
~ OVERSIZED
~ANTISIPHONING
CHANNEL
7
-
...
Metal Construction Association
MEMBER
~
-,
~ IU'LD'" ~
SPENCER
STEEL SUPPLY
ANDERSON
STEEL SUPPLY
IJI:FIRlJGAllEo:Jrl.1FAN'f
Fayetteville, NC
www.unioncorrugating.com
TIFTON ORANGE UNICO
STEEL PRODUCTS STEEL ROOFING METAL PRODUCTS
VICKSBURG
METAL PRODUCTS
DAYTON
METALS
:io _~
Installation Instructions for YIasterRibI~
Roofine
Slopes ofless than 3" in 12" are not recommended. For slopesof3" on12" or greater, end lap panels 6".
Side laps should face away fromthe prevailing wind. Lay the first sheet along the eave at the down-wind side ofthe roof, farthest away from
the direction of the prevailing winds. (See Figure #4). Install sheets in the sequence shown in Figure #4.
Fi~re #4
Prevailing Wind
2x4's
-
2'
CENTERS
Maximumpurlin spacing for
roof 2' on center
Install Metal Directly
To Wood Frame
-Use Maximum 2' PurlinSpacing
-Install Metal
*DO NOT USE THIS OPTION
FOR HEATED SPACES
Install Metal
On Solid Deck
-Lay Plywood Deck
.Apply 30tb. felt paper
-lnstallMetal
Install Metal
Over Existing Shingles
-Apply 30 Ib felt paper
.InstallMetal
*Proper ventilation and vapor barrier protection recommended for heated spaces.
Allow an overhang of2" at the eave to provide for a drip edge. Use inside closure at eave to prevent insect or bird infestation at openings.
To protect against uplifting winds and to provide a finished appearance, apply rake trim or other standard gable trim. Apply fasteners every
6-10".
14" ridge roll or ridge cap is recommended to prevent leakage. Seal off ridge and panel using outside closure strip.
....-.....,..,......-..- .
- ,.. .
Use of3/8" side lap tape is recommended. Apply the tape as shown in Figure #6 along the "top of all lap ribs. Do not block the siphon channel
with the tape. For best results, apply a 7/8" lap tek screw into the crown of the ribto secure the side lap.
Fieure #6-Proper Application of Side Lap Tape
Sidine
For best results, start siding at a door, window or other opening in the wall. Use comer trim, base molding, eave trim, and other trim to
improve ~e weather-tightness and appearance of the structure.
ALLOWABLE UNIFORM LOADS .PERSQUARE FOOT
Maximum purlin spacing for roof2' on center and maximum girt spacing for sidewall 3' on center.
Place fasteners in the pan of panelfor best results.
(Three Spans or More)
LIVE LOADING WIND UPLIFT LOADING
Span (inches) 18" 24" 30" 36" 48" 60" 72" 18" 24" 3D" 36" 48" 54" 72"
29 Gauge 200 112 72 50 28 18 14 281 158 101 70 40 25 18
26 Gauge 268 151 97 67 38 24 24 368 207 132 92 52 33 23
NOTES:
The panel weight has been deducted from the allowable stress values.
The wind uplift stress values have been increased by 33-1/3%.
The properties and load tables are for the panel alone.
The panel section properties have been calculated in accordance with,the 1996 AIS1Specification.
Steel panel material conforms to ASTM A446-85.
MasterRibGilUL Ratings: UL2218 Impact Resistance Class 4 - UL 790 Fire Resistance Class A
26 Ga MasterRib~ Metro-Dade County, FL Approval NOA #02-0726.06, Florida Code Approval #FL 72
and ASCE 7-98 Compliant (meets FL Bldg Code); 29 Ga MasterRib~ Florida Code Approval #FL2287
It is the users responsibility to verify aU applicable code requirements for the area, check aU measurements, and determine suitability of product for job. IMPLIED
WARRANTIES OF MERCHANTmILITY AND FITNESS FOR PARTICULAR PURPOSE ARE DISCLAIMED. Copyright i!;:) 1998 by Union Corrugating Company.
All rights reserved. No part of this document may be reproduced or distributed in any form whatsoever without prior writteri authorization. Rev 5/04
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542
813-780-0020 FAX: 813-780-0021
OWNER'S NAME
PHONE CONTACT FOR
JOB ADDRESS
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
WORK PROPSED: 0 NEW CONSTRUCTION
o ADDITION
(OBTAIN FROM
DALTERATION A REPAIR
o DEMOLISH
o INSTALL
PARCEL 10 #
o SIGN
PROPOSED USE: DSGL FAMILY DWELLING
o COMMERC IAL
o MOVE
DMULTI - FAMILY
o INDUSTRIAL
0# OF UNITS
o SWIMMING POOL
~OBILE HOME
o OTHER
~~TAURANT & HEALTH DEPARTMENT A"PPROVAL
DESCRIPTION OF WORK . S{(\ N <Sr\ I:), fJ.f<..q thm€- T
BUILDING SIZE d ~ x. 53 SQUARE FOOTAGE )2. 7'7--
!foe ~ 0 \/eJ-.
I'
HEIGHT J ("',
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
& (l),.JET ENERGY FORMS.
FORMS~
'C(O. .:-~ f/P-M) T
PERMITS REQUESTED
J:1 BUILDING
o ELECTRICAL
5aa~
$" ()
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
o Progress Energy 0
W.R.E.C.
o PLUMBING
o MECHANICAL
$
VALUATION OF MECHANCIAL INSTALLATION
o GAS
o ROOFING
o SPECIALTY
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAD YES 0 NO
SIGNATURE
~~71~~
COMPANY
BUILDER
STATE CERT OR REGIST #
;******************************************************************
ELECTRICIAN
COMPANY
SIGNATURE
STATE CERT OR REGIST #
******************************************************************
PLUMBER
COMPANY
STATE CERT OR REGIST #
SIGNATURE
******************************************************************
MECHANICAL
COMPANY
SIGNATURE
STATE CERT OR REGIST #
*****************************************************************
OTHER
COMPANY
SIGNATURE
STATE CERT OR REGIST #
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign po~tions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A,etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for 'a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
yaf~jP'4- '7ft~ ~
SIGNATURE: OWNER OR AGE~ SIGNATURE: CONTRACTOR
acknowledged
,20_
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____day of
by
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____ day of
by
acknowledged
20
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
C1ho is personally known to me, or
Dwho has produced
(type
and whoD did D did not
of identification)
take an oath.
Dwho has produced
(type of identification)
and who D did O:lid not take an oath
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped
DISCLOSURE STATEMENT FOR OWNER
CITY OF ZEPHYRHILLS BUILDING DEPARTMENT
I,
agree to the provisions of this instrument.
have read and fully understand and
The undersigned states and affirms that he or she is desirous of constructing,
renovating, adding to or reroofing his or her own domicile, that he or she
actually occupies, or will occupy by said domicile, and same is not for
rent, lease or sale. That he or she shall comply with the following conditions:
1. That the owner and he or she alone shall act as the builder for all phases of
construction.
2. That the owner will comply with all provisions of the City of Zephyrhills
ordinances and codes pertinent to the building.
3. That in the event various phases of construction are subcontracted, he will
engage only properly licensed subcontractors and will personally supervise
such work.
4. That in the event the Building Inspector shall require corrections to be made,
the owner will assume full responsibility to insure they are made, and upon
completion will call for a reinspection before proceeding with the building.
5. That the owner shall assume full responsibility for the construction and will
not expect supervision of his work from the City of Zephyrhills Building
Department.
6. That prior to final inspection any additional fees, including reinspection
fees, must be paid in full. A written request from this office shall
constitute an official notice to pay additional fees.
7. That the owner shall comply with all City, State and Federal laws in regard to
social security, workman's compensation, lien laws, etc., where applicable.
8. That the owner shall comply with all the safety codes issued by the Florida
Industrial Commission.
9. State law requires construction to be done by licensed contractors. You have
applied for a permit under an exemption to that law. The exemption allows
you, as the owner of your property, to act as your own contractor with certain
restrictions even though you do not have a license. You must provide direct
onsite supervision of the construction yourself. You may build or improve a
one-family or two-family residence or a farm outbuilding. You may also build
or improve a commercial building, provided your costs do not exceed $25,000.
The building or residence must be for your own use or occupancy. It may not
be built or substantially improved for sale or lease. If you sell or lease a
building you have built or substantially improved yourself within 1 year after
the construction is complete, the law will presume that you built or
substantially improved if for sale or lease, which is a violation of this
exemption. You may not hire an unlicensed person to act as your contractor or
to supervise people working on your building. It is your responsibility to
make sure that people employed by you have licenses required by state law and
by county or municipal licensing ordinances. You may not delegate the
responsibility for supervising work to a licensed contractor who is not
licensed to perform the work being done. Any person working on your building
who is not licensed must work under your direct supervision and must be
employed by you, whi~h means that you must deduct F.I.C.A. and withholding tax
and provide workers' compensation for that employee, all as prescribed by law.
Your construction must comply with all applicable laws, ordinances, building
codes, and zoning regulations. .r
OWNER'S SIGNATUR~. ~~~?k~ . DATE II/cf/lodt{
ADDRESS ~~ _ _ -.:. __L_ . _~/!J 1133 ')~'i--
PHONE ~-'---~
WITNESS
PERMIT #