Loading...
HomeMy WebLinkAbout04-3641 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 3641 Permit Number: 3641 Issued: 12 02/2004 Permit Type: NEW SINGLE FAMILY DWELLING Class of Work: 101:-NEW CONST/SFR Proposed Use: SINGLE FAMILY RESIDENTIAL Sq. Feet: Est. Value: Cost: 100,400.00 Total Fees: Amount Paid: 4,416.01 Date Paid: A dress: 6444 A HVILLE DRIVE ZEPHYRHILLS, FL. Township: Range: Lot(s): 5 Block: Section: Book: Page: Subdivision: SILVER OAKS VILLAGE Parcel Number: 03-26-21-02200-00BO-0500 Name: VILLAGE SQUARE BUlL E Addr: P.O. BOX 1536 ZEPHYRHILLS,FL. 33539 Phone: 813 788-6257 Lic: Work Desc: NEW SINGLE FAMILY DWELLING VILLAGE S U BUILDERS, INC. 6444 ASHVILLE DRIVE ZEPHYRHILLS, FL. 33542 Phone: PL E WATER CONNECTION RESIDENl BUILDING FEE IRRIGATION METER 419.00 IRRIGATION CONNECTION 784.50 RADON 180.00 PARK FEES SF 175.00 MECHANICAL FEE 20.08 WATER METER RES 3/4" 769.56 69.82 180.00 ER U DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED LINTEL PRE-METER WATER SHEATHING FRAME MISC SEWER MISC INSULATION WALL MISC MISC. MISC. INSULATION CEILING MISC. MISC. MISC. DRIVEWAY MISC. MISC. REINSPEcnON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. ~ ~ C ORS SIGNATURE PERMIT OFF I CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Village Square Builders 6444 Ashville Dr. SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 50.00 OTHER AREA UNDER ROOF: $ 50.00 OTHER: $ - VALUATION $ 100,400.00 FEE SHEET $ 483.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 784.50 CREDIT: $ - BUILDING LESS CREDIT: $ 784.50 ELECTRICAL: $ 106.05 PLUMBING: $ 96.00 MECHANICAL: $ 69.82 SUB-TOTAL $ 1,056.37 RADON: $ 20.08 TOTAL $ 1,076.45 SEWER: $ 1,616.00 WATER: $ 419.00 IRRIGATION: $ 175.00 TOTAL: $ 2,210.00 WATER METER: $ IRRIGATION METER $ 180.00 180.00 PARK IMPACT FEE:1 $ 769.56 t SUB-TOTAL $ 4,416.01 I SIF'S: $ 97.5% $ 2.5% $ (jJL/b rdJ e.o. TIF'S'I$ 99% $ 1% $ - I 6,110.01 I TOTAL: $ N .... 0 Q) .... "0 C 0 ""-' c 0 .... '-'- 0 Q) "0 en JL - l.C) lr 8 .." ell rn 0 ..d ~ ~ bD Q) E-< .S "'l:j cu 8 ~ ~ _.:: ;:l ..d ~ ~!:Q lJ:l p., Q 0 CXJ Q):: ~ oo:j< ~ Q)bD~ C":l~ ~ ~ C)~cc II ctS - 0 ell ~~ ;:l:> 550 ~~ C" -- C/) !J It:) ~ t\l ell....,==-= Q)ooell...., b.() - ....:I .... ctS ~ 8 ...... > J.o ...... - Q) ..... rn Po. > . C,) d - ---- ..-- - - - J.o Cl ...-. :> Q) J.o Po. -- ,.,-.,.~_"-,~A'~~-' _,__ ._......i \_lfi:-ii~i... . ;u.: v AlLL~G CCSL:;, FLORIDA BUlLDINC CODE, NA TlONAL ELECfRlC CODE ANI CITY OF ZEPHYRHlLLS ORDINANCES ~.IDfl <;. ~ ----- -I '&'1'9 __-- ,.;..-"- I I I ",y,) I ';J I ~ I 'I - r~ u, : );1 ~ ~ / I ~L~~ , L _~N' ,Q9 Lj ..-\ c;.r:";'Q'V .....,k -.l.__~ , Lll --.......... VOI~JO- 'A1NnO:J O:JSVd .::10 SO( 1 Vld NI 030t:l083~ SV ,. ONY vOI~Olj'A1NnOJ ( NOl183S NI 8NIA l (INV ve .::10 gg 38\1 d 'l >1008 1 SlllHClAHd3Z '98 C I , -/r--/ [~:~;; ~rl .J Mtl,~~.N ,6b'gZ~ ~ , {Ol gl ~, -, M. tl,I:I:.68N ,OO'9Z, (; M. -vl,I:I:.6BN ,00'9(';, II) r ,- 0 M.-vl,I:I:.6BN 0 ^ . "T\ . M.tl,I:I:.6BN .OO'9zr ~~! I Vi :::l Z Ci to> q: ~"JI' ~: O-i- 'l '-, :~ , 1m o ;1>- '0 '--.J. ;u o :r. --I I I 1 I I I I I lJ ( I I I 1 1 I I I I I I , : (1)1 : ~II 'I ~; OJ 'I : ~\ 1 .' . I ___ ~/r'- : L~!i'Jih I ' . I I : I I I H~~v Sld ) I I I ~ ~ -< 0' m o o )> :::l .~~~ , I rl I 9' z :gl , 0 -I {JJ IS 1 r I a~ 1 ~ ~l I ~1 ~'I I vii '" ~\ tn \ . I !J11 {J.!, 8.\ I I M.tl,I:I:.69N I .t.9'90, r; IN3'~3s\f3 t;, I )"1111Hl ,00'0, . IH '~ 00_1 ~"tn" ': ~ ,M"tl,H:.6BN " I ,69'(;6 I cj; I 6~ ;-J . I ~ 01 U1') ~O ,? / t() '~~:T:O(n1Lr- -: /' 3r~o 3SVlld 30Vllli\ -..j ",>- , "" _ / ---- S>lVO H3t\ liS j() - - ---....-.Dl10fil 1 / JNll ).,HVONn08 I 1N3Yi3SVJ" r- -..j 130VNIVHO ,00'9~~-::- .... I m; //q:~ ~I / '1 //::t:::: --:!-- I -7'---;:. --- _ - t:: -;:'r " 1N3t'l3SV3 H3.:J.:HI8 JdV::JSONVl ,OO'g 9~ IIn I ,0 I~. I~ I . ({) o O. M.vl,I:I:.6BN ::'I: ,(Jo'o,r \]oJ o o Cl tJ 0, v; 0' ,. :I;; H ;iJ N )0 N VI ~ <t . , ~ )>, '!. l# \f3(jY NOI1N3J.](j 9 ~gjo S'ld :-' U1 o. r ... o I.,::> IN31''OSV3 6 ,e> 30VNlv~a .OO'S; 1 O~V^31n08 ONVlI3, JO 3NIl ).,VM .:10 IHClIH 111110S --- ----- OM~L - ----- ------=:: - ~~ ___~ 'fll'PlYf ""'w \~NV1.~~J v''fltn_Y.:J~ TIE1Vl 31~1l - At] ,00'6 , -----:- Ob'!) ,~{rLjr ,qL', , ,filQ'69 30NY;l$IO .3~jo(;J:(;G\ 3.tt~I:s-:.6\ :l;;jit,tl:.t)\ M,;io:ZS:~;6' 3, u-vzS:I:.6i n01D,3M 3l0Vl 3Nil. - J[\ / I /{ /~ ( / Ll n ;u Pl () "0 c;o coo ~ tJ (f) " r ::uz~ ~"lJ:::U or ;0>0 CJ -t po. VJCOA oOUl .....q 0 -o^:::; > (" r- ~ 51'S: O-uCl 0>[11 o f~ 'U ~ In :1: --I 01'? .-< vi Ul . P1 ":i! 5;00 ;uoZ - C P'l' ~ ~. 0' '-, 3'SVl-1;d, o PLUMBING APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDI~GDEPARTME~T 1/./~J<'~' &~(/~C OWNER'S N1IME6 ffI f1 (~ P't ~ I --r:; c ("' <:.- JOB ADDRESS~i LEGAL DESCRIPTION: LOT(S) ~ BLOCK l) PARCEL IDft :3-6l.(.-c:l.I-DR~V~{)o6iJ- /J5"DO (OBT~rN l'l /,?~~)~ D:::"::'0":~ 1'1 I ! 1:1 PHONE ;> s-: ,11 'i 1 WORK PROPSED: P(NEW CONSTRUCTION DSIGN PROPOSED USE: [JSGLFAMILY DWELLING o COMMERCIAlJ [JADDITION [JALTERATION ! FROM PRO P fir i o REPAIR [J INS'rALL [JMOVE o DEMOLISH OMULTI-FAMIIJY o INDUS'rRIAL 0# OF UNI'l'S [J SWIMMING POOL o MOBILE o OTHER $'/r~~" '-"ill . ~ (..; DESCRIPT F WORK o RESTAURANT & HEALTH DEPARTMENT AJ;>PROVAL Y L, ~ ~ J I -r -t. 1<10...,., A",lf~ Uwc 011< If1 ?-oo.~ ~ SQUARE FOOTAGE HEl1GHT BUILDING SIZE RESIDENTIAL: COMMERCIAL: , I AT'rACH . (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & fjC( 1) SE'Ij ENERGY FORMS ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FOR : PROPERTY SURVEY REQU:::::~L~:~::::CTIO~ $ VALUATION OF TOTAL CONSTRUCTION. [] EJJECTRICAIJ AMP SERVICE o [] BUILDING FLORIDA POWER o ul. E.<C:~ ) INSTALLAT~~ [J MECHANICAL $ -- VALUATION OF MECHANCIAL o GAS [J ROOFING o SPECIALTY [] OTHER TYPE OF CONSTRUCTION: 0 BLOCK [] FRAME o STEEL IJ O'l'HER FINISHED FLOOR ELEVA'fIONS IS PROJECT IN FLOOD ZONE AREA 0 YES o NO BUILDER ELECTRICI SIGNATURE PLUMBER SIGNATURE MECHANICAl. SIGNA'rURE ~ COMPANY STATE CERT OR REGIS'l' CITY PROCESSING # *************** ************************************************ OTHER COMPANY ST1\.TE CERT OR REGIST # SIGNATURE CITY PROCESSING # ***************************************************************** I ._~~-~.:-- NOTICE OF DEED RESTRICTIONS ~he undersign~d understands that this permit may be subject to "deed restrictions" which 'f' ay be more restrictive than City regulations. 'rhe undersigned assumes responsibility for. i ompliance with any applicable deed restrictions. i,. UNLICENSED CONTRACTORS AND CONTRAC'rOR RESPONSIBILITIES of the ~wner tta~ hired a contractor or' contractors to und~rtake work, they may be required :~oo be llcensec!- Jon accordance with state and local regulatlons. If the contractor is not 1.. icensed as required by law, both the owner and contractor may b~ cited for a misdemeanor : iolation under state law. If the owner or intended contractor are uncertain as to what iRicensing requirements may apply for the intended work, they are advised to contact the !~ity of Zephyrhills Building Department, 813-788-661l. !jFurthermore, if the owner has hired a contractor or contractors, he is advised to have the ,pontractor (s) I sign portions of the "Contractor Sections" of this application for which they i~illbe responsible. If you, as the owner signs as the contractor, you are indicating that !~' au, rather than the contraqtor, are responsible for the work. If the contractor wishes iOU to sign as contractor th,at may be an indication that he is not properly licensed and is ,ot entitled to permitting privileges in the City of Zephyrhills. 1. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES I' . , . I. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) .. certify tha* I, the applicant, have been provided with a copy of "Florida's Construction i lien Law - HOlheowner's Protection Guide" prepared by the E'loridaDepartment of Agricul ture ,I . . land Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I 'I' ave obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. IE. CONTRACTOR' S/OWNER' S AFFIDAVIT iI certify that all the information in this application is accurate and that all work will ibe done in compliance with all applicable laws regulating construction, zoning, and land [development. I pplication is hereby made to obtain a permit to do work and. installation as indicated. I i certify that fio work or installation has commenced proior to issuance of a permit and that i all work will II be p.erformed to meet standards of all laws regulating construction, City !eodes, zoning regulations, and land development regulations in the jurisdiction. I also [certify that':if: understand that the regulations of other governmental agencies may apply to ithe intended ~ork, and that it is my responsibility to identify what actions I must take to Ibe in compliapce. Such agencies include but are not limited to: *Department of [Environmentall Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment i*SouthV'/'est c'lprida Water Management District-Wells, Cypress Bayheads, Wetland Areas, lA1teri~g Wate~courses !*Army Corps oiE Engineers-Seawalls, Docks, Navigable Waterways I*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, iWastewater Tr~atment, Septic Tanks [*U. S. Environmental protection A.geney-Asbestos abatement II also certif~ that, if fill material is to be used in Flood, Zone "A" or "A,etc.", it is . [understood that a drainage plan addressing a "compensating volume" will be submitted which I lis prepared by a professional engineer registered in the State of Florida prior to permit I issuance. . , fA permit issued shall be construed to be a license to proceed with the work and not as i authority to violate, cancel, alter, or set aside any provisions of the technical codes, j nor shall issuance of a permit prevent the Building Official from thereafter requiring.a icorrection of] er)::~rs in plal',1s, construction, or violations of any code. gvery permit i iissued shall pecoIlle invalid' unless the work: authorized by such permit is commenced within [six: monthsofl issuance, or if work authorized by the permit is suspended or abandoned for a I period of sixl months after. the time the work is commenced. One 90 day extension of.time I may be allowep for thep~rmlt with fee charge of $15.00. The extension shall be requested lin writing to! the Building Official. An approved inspec1:ion must be logged during each six I month period,1 or the project will be considered abandoned. [WARNING 'l'O OW~ER: YOUR FAILURE TO RECORD A NOTICE Olf COMMENCEMENT MAY RESULT IN YOUR ! PAYING 'l'WICE IFOR IMPROVEMEWl'S TO YOUR PROPER'l'Y. IF YOU INTEND '1'0 OBTAIN lfINANCING, CONSUL'l' I WrrH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO'rrCE OF COMMENCEMENT. JOBS' UNDER ,. i : $2,500 IN VALUE DO NOT NEED TO RECORD AND POS'I' A "NOTICE OF COMMENCEMENT". ! SIGNATURE: OWNER' OR AGEN'l' SIGNATURE: CONTRACTOR STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _day of by acknowledged 19 (name of person acknowledged) Dfho is personally known to me, or of identification) take an oath. o who has produced (type of identification) and who Ddid O:iid not take an oath I I Signature of jperson takingacknowleclgement Signature of person taking acknowledgment I Name typed, prj.nted or stamped I Name typed, printed or stamped l0'd It:1101 I I. r' ,. SSSS - 8TH StnIot ZeptlY'f'lls. FL 33642 City of ZephyrhiHs Bui~din~1 !).~partment .'Fax ~. ..,-{ Bobbie ~t1and ).- ...- Fax.cove( only ~# ~ Judy :faIa 727~15-7000 ....... h_ 1011912004 Ita: Address Request cc: [J U.....* 0 If'or RevIew tJ PI_ eo........ X P..... R8IIb' 0..1.... Recycle I would like to retluest ........... for the foll_... (4)..... fMIIIr tlWelli!ialla: (11.........-~~~I..._.....t,...IJII-,~ (3) ~........ wUl'lw; VICTORIAN WAY Parcell.D. N3-2..21_1 #~&.ot 20 (, II 1/ r (3) F...._. will... VICTORIAN WAY Parcel I~D. toJ....21oG21O ~IO Lat 11 " II ,r (.) Fran.....wld lie VlCTOIlWIWAV ......I.D.towNi.Q2ICI ,.aSllitIO Lo'''. "'1Jr H -'t ........~ "'.113-710-0020 or'" 113007-..21. ~"? ,....... o:IudWI" '. " OCT-19-2004 113:55 813 '(ae 0e21 P.01 lB/m'd BB01. Sl8 l.G1. M3I~3~ ~3a ^lNno) O)St:1d l.G:Sl v00G-l.G-l)O FORM 600A-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A LAUREL OAK MODEL Builder: VILLAGE SQUARE Permitting Office: ZEPHYRH'LLS, FL Permit Number: Jurisdiction Number: Project Name: Address: City. State: Owner: Climate Zone: Central 1. New construction or existing 2. Single family or multi.family 3. Nwnber of units, if multi.family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type a. Clear - single pane b. Clear. double pane e. Tint/other SHGC . single pane d. Tint/other SHGC - double pane 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A e. N/A 9. Wall types a. Frame, Wood, Exterior b. Frame. Wood, Adjacent e. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A e. N/A ll. Ducts a. Sup: Unc. Ret: Une. AH: Attic b. N/A New Single family I 3 No 1393 ft' 159.0 ft' 0.0 ft' 0.0 ft' 0.0 ft' R=O.O, 189.0(p) ft R= 11.0, 1341.0 ft' R=I!.O, 189.0 ft' R=30.0, 1393.0 ft' Sup. R=6.0, 223.0 ft 12. Cooling systems a. Central Unit Cap: 28.6 kBtu/hr SEER: 12.00 b. N/A e. N/A 13. Heating systems a. Electric Heat Pwnp Cap: 28.8 kBtu/hr HSPF: 7.60 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 50.0 gallons EF: 0.86 b. N/A e. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-MuItizone heating) Glass/Floor Area: 0.11 PASS Total as-built points: 21667 Total base points: 21984 I hereby certify that the pia by this calculation are i Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge@ (Version: FLRCPB v3.22) FORM 600A-2001 . . SUMMER CALCULA liONS Residential Whole Building Performance Method A - Details I ADDRESS: . ZEPHYRHILLS, FL, PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1393.0 25.78 6464.1 Single, Clear NW 1.0 7.0 36.0 37.74 0.98 1337.4 Single, Clear NW 6.0 7.0 36.0 37.74 0.67 912.3 Single, Clear SW 1.0 3.0 6.0 52.82 0.82 259.0 Single, Clear SW 1.0 6.0 15.0 52.82 0.96 764.6 Single, Clear SW 1.0 5.0 8.0 52.82 0.94 396.2 Single, Clear SE 1.0 3.0 6.0 56.64 0.81 275.6 Single, Clear NE 1.0 3.0 16.0 43.65 0.86 603.8 Single, Clear NW 10.0 6.0 15.0 37.74 0.58 325.6 Single, Clear NE 6.0 2.0 3.0 43.65 0.45 58.3 Single, Clear SE 10.0 6.0 15.0 56.64 0.44 374.9 Single, Clear NW 6.0 3.0 3.0 37.74 0.56 63.4 As-Built Total: 159.0 5371.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 189.0 0.70 132.3 Frame, Wood, Exterior 11.0 1341.0 1.90 2547.9 Exterior 1341.0 1.90 2547.9 Frame, Wood, Adjacent 11.0 189.0 0.70 132.3 Base Total: 1530.0 2180.2 As-Built Total: 1530.0 2180.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.0 1.60 28.8 Exterior Wood 42.0 7.20 302.4 Exterior 42.0 4.80 201.6 Adjacent Wood 18.0 2.40 43.2 Base Total: 60.0 230.4 As-Built Total: 60.0 345.6 CElUNG TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1393.0 2.13 2967.1 Under Attic 30.0 1393.0 2,13X1.00 2967.1 Base Total: 1393.0 2967.1 As-Built Total: 1393.0 2967.1 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 189.0(p) -31.8 -6010.2 SIab-On-Grade Edge Insulation 0.0 189.0(p -31.90 -6029.1 Raised 0.0 0.00 0.0 Base Total: -6010.2 As-BuiItTotal: 189.0 -6021.1 INFIL TRAnON Area X BSPM = Points Area X SPM = Points 1393.0 14.31 19933.8 1393.0 14.31 19933.8 EnergyGaugd DCA Fonn 6OOA-2D01 EnergyGaugeelFlaRES'2001 FLRCPB v3.22 FORM 600A-2091 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details t ADDRESS: ,ZEPHYRHlLLS, FL, PERMIT #: BASE AS-BUlL T Summer Base Points: 26265.4 Summer As-Built Points: 25268.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x OSM x AHU) 25268.7 1.000 (1.087 x 1.150 x 1.10) 0.284 1.000 9873.6 26265.4 0.4266 11204.8 25268.7 1.00 1.375 0.284 1.000 9873.6 EnergyGauge TM DCA Form 6OOA-2001 EnergyGaug~laRES'2001 FLRCPB v3.22 FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , ZEPHYRHILLS, FL, PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Paints Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Pointl .18 1393.0 5.86 14&9.3 Single, Clear NW 1.0 7.0 36.0 12.23 1.00 439.5 Single, Clear NW 6.0 7.0 36.0 12.23 0.99 437.1 Single, Clear SW 1.0 3.0 6.0 9.22 1.06 58.7 Single, Clear SW 1.0 6.0 15.0 9.22 1.01 139.7 Single, Clear SW 1.0 5.0 8.0 9.22 1.02 75.1 Single, Clear SE 1.0 3.0 6.0 8.34 1.09 54.5 Single, Clear NE 1.0 3.0 16.0 12.00 1.00 192.1 Single, Clear NW 10.0 6.0 15.0 12.23 0.99 181,6 Single, Clear NE 6.0 2.0 3.0 12.00 1.00 36.0 Single, Clear SE 10.0 6.0 15.0 8.34 1.76 220.3 Single, Clear NW 6.0 3.0 3.0 12.23 0.99 36.3 As~uilt Total: 159.0 1870.9 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 189.0 1.80 340.2 Frame, Wood, Exterior 11.0 1341.0 2.00 2682.0 Exterior 1341.0 2.00 2682.0 Frame, Wood, Adjacent 11.0 189.0 1.80 340.2 Base Total: 1530.0 3022.2 As~uilt Total: 1530.0 3022.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.0 4.00 72.0 Exterior Wood 42.0 7.60 319.2 Exterior 42.0 5.10 214.2 Adjacent Wood 18.0 5.90 106.2 Base Total: 60.0 286.2 As-Built Total: 60.0 425.4 CElUNG TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1393.0 0.64 891.5 Under Attic 30.0 1393.0 0.64 X 1.00 891.5 Base Total: 1393.0 891.5 As-Built Total: 1393.0 891.5 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 189.O(p) -1.9 -359.1 S1ab-On-Grade Edge Insulation 0.0 189.0(p 2.50 472.5 Raised 0.0 0.00 0.0 Base Total: -359.1 As-8uilt Total: 189.0 472.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 1393.0 -0.28 -390.0 1393.0 -028 -390.0 EnergyGaugef> DCA Form 6OOA-2001 EnergyGaugee/FlaRES'2oo1 FLRCPB v3.22 FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details J ADDRESS: , ZEPHYRH1LLS, FL, PERMIT #: BASE AS-BUlL T Winter Base Points: 4920.1 Winter As-Built Points: 6292.5 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 6292.5 1.000 (1.078 x 1.160 x 1.11) 0.449 1.000 3922.3 4920.1 0.6274 3086.9 6292.5 1.00 1.388 0.449 1.000 3922.3 EnergyGauge'N DCA Form 6OOA-2001 EnergyGauge4M9aRES'2001 FLRCPB v3.22 FORM 600A-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , ZEPHYRHlLLS, FL, PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 50.0 0.86 3 1.00 2623.63 1.00 7870.9 As-Built Total: 1870.9 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 11205 3087 7692 21984 9874 3922 7871 21667 I PASS I EnergyGaugeâ„¢ DCA Form 600A-2001 EnergyGauge4DlFIaRES'2001 FLRCPB v3.22 FO~M 600A-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: , ZEPHYRHILLS, FL, 6A-21 INFIL TRA noN REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS SECTION REQUIREMENTS FOR EACH PRACncE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sa.ft. window area: .5 cfmlsa.ft. door area. Exterior & Adjacent WaDs 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & toplbottom plates; between walls and floor. EXCEPTION: Frame waDs where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the too olate. Floors 606.1 ABC.1.2.2 Penetrations/openings >1/8" sealed unless baeked by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter oenetrations and seams. Ceilings 606.1 ABC.1 .2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltratjon barrier is installed that is sealed at the Derimeter at oenetrations and seams. Recessed Lighting Fixtures 606.1ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned soace, tested. MuIti-storv Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavitv between floors. Additionallnfillration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES 'must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (aas) must be Drovided. External or built-in heat traD reauired. Swimming Pools & Spas 612.1 Spas & heated poo/s must have covers (exceptso/ar heated). NOI'K:Ommercial poo/s must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 callons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 SeDarate readilY accessible manual or automatic thermostat for each sYStem. Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugel\l DCA Form 600A-2001 EnergyGauge<<llFlaRES'2001 FLRCPB v3.22 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 83,6 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi-family 3. Number of units, if multi-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (fF) 7. Glass area & type a. Clear - single pane b. Clear. double pane c. Tint/other SHOC - single pane d. Tint/other SHGC - double pane 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A II. Ducts a. Sup: Unc. Ret: Unc. AH: Attic b. N/A , , ZEPHYRHILLS, FL, New Single family 1 3 No 1393 ft2 159.0 ft2 0.0 ft2 0.0 ft2 0.0 ft2 R=O.O, 189.0(p) ft R= 11.0, 1341.0 ft2 R=11.0,189.0ft2 R=30.0, 1393.0 ft2 Sup. R=6.0, 223.0 ft 12. Cooling systems a. Central Unit Cap: 28.6 kBtuIhr SEER: 12.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 28.8 kBtuIhr HSPF: 7.60 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 50.0 gallons EF: 0.86 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *NOTE: The homes estimated energy peiformance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP A/DOE EnergyStarâ„¢ designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec,ucfedufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge@ (Version: FLRCPB v3.22) Page 1 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J 10/2012004 Report Prepared By: Chris' AlC Company For: LAUREL OAKlVILLAGE SQUARE ZEPHYRHILLS, FL Design Conditions: Tampa Indoor: Summer temperature: 75 Winter temperature: 72 Relative humidity: 50 Outdoor: Summer temperature: 95 Winter temperature: 34 Summer grains of moisture: 116 Daily temperature range:Medium Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) 24,271 3,120 27,391 24,682 24,273 3,121 27,394 24,683 3,700 420 4,120 4,036 164 0 164 341 1,107 32 1,139 742 4,893 871 5,764 6,342 2,621 230 2,851 985 2,345 681 3,026 2,545 2,430 325 2,755 1,994 2,094 137 2,231 2,200 1,459 32 1,491 1,833 204 0 204 397 3,256 393 3,649 3,268 24,271 3,120 27,391 24,682 Building Component Whole House First Floor BED2 WIC2 HALL SA TH Living Room Kitchen Dining Room BED3 Laundry M1BA TH MIWIC MASTER Whole House HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. Load calculations are ~ only, actual loads may vat}' due to......... and consIruc:lion dill'8l8nces. 888736-1101 @ ,A,,,,,,-t-t .. .a Ib~ " '~r1 11':0./(," ~ 'l .. ,,,,td:! ~~ J..-,tI. :.11 .. I~Y' "~ t '" , " ~ 10/4/" ~ ~A- U~e./ (fY"K" ,(JuJ CONTRACTOR #= 999999 NAME= VILLAGE SQUARE BUILDERS ADDI:~:: 644.<t ASHV I Ll..E N~ C/ST= ZEPHYRHILLS, FL 33541 CENTRAL PERMITTING P(:\SCO CCJl.Jrrry" FI...OF,: I D(~ ~6'T"~~::1 06/3<)/03 '?':!:~l~:~ :r.5~3:r. Pf~iHF :: :I. OF :/. I :::; SUE ()FF J l.::r:: D 1:~i:::CE:I: PT l\!lJj'.j BR :: C )n:;.~;~!; ~:.!~:.;i:;:.! DFFITE::: Df~):OE CITY Fcm:: CHECK ** :L (1~.'j6 CITY OF Z-HII...I...S N3641 CONTRACTOR= 999999 TOT AI... AMOUNT:: ACCNT COMPNY ACCOUNT CENTER 114 B450 - 363000 - 2 2<'" n i'~:2 {.iMOUNT DESCRIPTION/PEF~MT DFITf~ DFUCR 29"42 ****** SOLID WASTE FEE 60 I:~ECE I VED BY .....~(t~~1L..........................................................................................