HomeMy WebLinkAbout04-3700
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
3700
Permit Number: 3700 Issued: 12/21/2004
Permit Type: NEW SINGLE FAMILY DWELLING
Class of Work: 101-NEW CONST/SFR
Proposed Use: SINGLE FAMILY RESIDENTIAL
Sq. Feet: Est. Value:
Cost: 136,350.00 Total Fees: 4,641.88
Amount Paid: 4,641.88 Date Paid: 12/21/200
Address: 6449 A HEVILLE DR
ZEPHYRHILLS, FL.
Township: Range:
Lot(s): Block: Section:
Book: Page:
Subdivision: SILVER OAKS VILLAGE
Parcel Number:
Name: VILLAGE SQUARE BUILDE
Addr: P.O. BOX 1536
ZEPHYRHILLS,FL. 33539
Phone: 813788-6257 Lic:
Work Desc: NEW SINGLE FAMILY DWELLING
VILLAGE SQUARE BUILDERS, INC
6449 ASHEVILLE DR
ZEPHYRHILLS, FL. 33542
Phone:
PLU
WATER CONNECTION RESIDENl
BUILDING FEE
RADON
419.00 IRRIGATION CONNECTION
946.50 WATER METER RES 3/4"
27.27 PARK FEES SF
I AL
175.00 MECHANICAL FEE
180.00 IRRIGATION METER
769.56
85.20
180.00
~Jrr
DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB
DUCTS INSULATED LINTEL PRE-METER WATER
SHEATHING FRAME MISC SEWER
MISC INSULATION WALL MISC MISC.
MISC. INSULATION CEILING MISC. MISC.
MISC. DRIVEWAY MISC. MISC.
REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
tt
NO OCCUPANCY BEFORE C.O.
CTORS :GNATURE PERM~
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
lo~~t I
APPLICATION FOR PERMIT
CITY OF ZEPHYRHILLS
BUILDING DEPARTMENT
DATE RECEIVED
PLANS REVIEW FEE
/1-30 -rJ,/
~ 'It I \~S{,~( 6v(I~A ( ~"-
OWNER'S NAME ~
JOB ADDRESS u4L-(1~1f, \Jr.
LEGAL DESCRIPTION: LOT(S) 1<; BLOCK t>
b)- J~<-d' - OoD!) -- (JOp;;,D{)" 0 t'j()
WORK PROPSED: ~NEW CONSTRUCTION 0 ADDITION DALTERATION
~~IGN 0 MOVE 0 DEMOLISH
PROPOSED USE: ~SGL FAMILY DWELLING oMULTI-FAMILY 0# OF UNITS
o COMMERCIAL 0 INDUSTRIAL 0 SWIMMING POOL
PHONE
"{ Ph-' (~7
SUBDIVISION<S~O.If\ PC)-
PARCEL ID #
(OBTAIN FROM PROPERTY TAX NOTICE)
o REPAIR
o INSTALL
o MOBILE HOME
o OTHER
DESCRIPTION OF WORK
c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL
pJe<0 r ~c;.1r -.(-h~
SQUARE FOOTAGE ~ d 7if 7 HEIGHT
BUILDING SIZE
RESIDENTIAL:
COMMERCIAL:
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
PERMITS REQUESTED
o BUILDING
$
VALUATION OF TOTAL CONSTRUCTION
o ELECTRICAL
AMP SERVICE
o FLORIDA POWER
o W.R.E.C.
o PLUMBING
o MECHANICAL
$
VALUATION OF MECHANCIAL INSTALLATION
o GAS
o ROOFING
o SPECIALTY
o OTHER
FINISHED FLOOR ELEVATIONS
P FRAME
o STEEL
o OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
IS PROJECT IN FLOOD ZONE AREAo YES
~NO
BUILDER
SIGNATURE
~
..........A-"'"
,-, --"-
.-
-_......~.
COMPANY
STATE CERT OR RE
CITY PROCESSING #
****************************************************************
SIGNATURE
COMPANY h:"f (Iq~
STATE CERT OR REGIST # (:;c.. -cC'~;!..,?o
CITY PROCESSING #
***************************************************
PLUMBER
COMPANY
STATE CERT OR R
CITY PROCESSING
SIGNATURE
SIGNATURE
****************************~***r1t/***~******1i
COMPANY IS ! c..- L-07:[;aM
STATE CERT OR REGIST # CA 05 57b
CITY PROCESSING #
MECHANICAL
***************************************************
OTHER
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
SIGNATURE
*****************************************************************
CONDITIONS OF PERMIT AFFIDAVIT
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictibns" which
may be more restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
l~cens~d as required by law, both the owner and contractor may be cited for a misdemeanor
v10Iat10n under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-788-6611.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which the
will be responsible. If you, as the owner signs as the contractor, you are indicating tha
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indication that he is not properly licensed and i
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR' S/OWNER' S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take t
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterlWastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each si
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSUL
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
acknowledged
1~
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____day of
by
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _ day of
by
acknowledged
19
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
C1ho is personally known to me, or
Dwho has produced
(type of identification)
and whoD did Ddid not take an oath.
o who has produced
(type of identification
and who Ddid [}:lid not take an oath
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped
Village Square Builders
6449 Ashville Dr.
SQ. FEET PRICE
MAIN OR LIVING: 2,727 $ 50.00
OTHER AREA UNDER ROOF: $ 50.00
OTHER: $ -
VALUATION $ 136,350.00
FEE SHEET $ 591.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 946.50
CREDIT: $ -
BUILDING LESS CREDIT: $ 946.50
ELECTRICAL: $ 136.85
PLUMBING: $ 106.50
MECHANICAL: $ 85.20
SUB-TOTAL $ 1,275.05
RADON: $ 27.27
TOTAL $ 1 ,302.32
.- '
SEWER: $ 1 ,616.00
WATER: $ 419.00
IRRIGATION: $ 175.00
TOTAL: $ 2,210.00
-
WATER METER: $ 180.00 /'
IRRIGATION METER $ 180.00
PARK IMPACT FEESI $ 769.561
SUB-TOTAL $ 4,641.881
SIF'S: $ 1,694.00
97.5% $ 1,651.65
2.5% $ 42.35
T IF'S 'I $
99% $
1% $
TOTAL: $ 6,335.88 1
~~;
::..:,\
~~~~~li'l~!~llllIllllIIlllIIlllIIlIIlIllIlllIrlllll
NOTICE OF COMMENCEMENT
Rcpt.: 830397
OS: 0. 00
11/10/04
Rec: 10.00
IT: 0 . 00
Dpty Clerk
STATE OF FLORIDA
COUNTY OF PASCO
The undersigned as Owner notifies all parties that improvements will be made to certain real property, and
in accordance w'ith Sectio~ 713.13, Florida Statutes, the following information is stated in the Notice of
Commencement:
DESCRIPTION OF PROPERTY:
Lot 15 Block B Silver Oaks Village - Phase Two, as per map or plat thereof
recorded in Plat Book 50, Pages 29 and 30, Public Records or Pasco County,
Florida.
GENERAL DESCRIPTION OF IMPROVEMENTS:
OWNER AND OWNER'S ADDRESS:
Residential Home
Village Square Builders, Inc.
6426 Huntington Drive
Zephyrhills, FL 33542
OWNER'S INTEREST IN THE PROPERTY DESCRIBED AS: Simple
CONTRACTOR AND CONTRACTOR'S ADDRESS:
Village Square Builser, Inc.
6426 Huntington Drive
Zephyrhills, FL 33542 JED PITTMAN PRSCO COUNTY CLERK
11/10/04 03:4~m 1 of , 1
OR BK 610:> PG 86,8
SURETY (if any) and SURETY ADDRESS: N/A
AMOUNT OF BOND: $ N/A
NAME AND ADDRESS OF LENDER, IF ANY, MAKING A LOAN FOR CONSTRUCTION OF THE
IMPROVEMENTS:
Community National Bank of Pasco County
Post Office Box 639
Zephyrhills, FL 33539
NAME OF PERSON WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM
NOTICES OR OTHER DOCUMENTS MAY BE SERVED:
Community National Bank of Pasco County
Post Office Box 639
Zephyrhills, FL 33539
IN ADDITION, OWNER DESIGNATED THE FOLLOWING PERSON(S) TO RECEIVE A COPY OF
THE LIENOR'S NOTICE AS PROVIDED IN SECTION 713.13, FLORIDA STATUTES:
Community National Bank
Of Pasco County
Post Office Box 639
Zephyr hills, FL 33539
EXPIRATION DATE: November 5, 2006
Larry Hersch
Attorney at Law
Post Office Box 1046
Dade City, FL 33526-1046
Village Square Builders, I
STATE OF FLORIDA
COUNTY OF PASCO
The foregoing instrument was acknowledged before me this 5th day of November 2004 by Lance A S 'th
Prisident of Village ~qua~e Bu~lders, Inc. who is personally known to me or who produc:d dAM';\Z~.# mO~~_
as identification, and did/did not take oath.
Witness my hand and official seal in the County and State last aforesaid this 5th day of November 2004.
NOTARY PUBLIC
~
STATE OF FLORIDA
COUNTY OF PASCO
THIS iS~T:O'~RTIFY THAT THE FOREGOING IS A
TRUE ANQ ~"&RRI;cij; c.OfY QP THE QOcCUMENT ON FILE
OlVQF::eUBLlC RECORD ,I~r lHISOFFICt WIT~ESS MY
t;lAN(r~No-O.EfJ~JAlSEACniIS ~AY OF
; <..J "tSM,'I~,,~"-k,-'.' ~
~, ,,:.;':~:: :'~);(Vu',V':: '. . l' ;; ~.
; Je(J(' "" l.ER~OF:clRtUIT COURT
'- ,~( '., ~ : ""
, '. DEPUTY CLERK
r ',<
, ,
t ( I
~ 1.1 '%' r r ~
\ ,) ~
~' \'.J '
\ ,-
FORM1600A-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
AUGUSTA MODEL Builder: YJLLAG3E SQUARE BU'""DE
Permitting Office:
ZEPHYRHfLLS, FL Permit Number:
Jurisdiction Number:
Project Name:
Address:
City, State:
Owner:
Climate Zone:
Central
1. New construction or existing
2. Single family or multi-family
3. Number of units, if multi-family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SHGC - single pane
li Tint/other SHGC - double pane
8. Floor types
a. SIa1>-On-Grade Edge Insu1ation
b. N/A
c. N/A
9. Wall types
a. Frame, Wood, Exterior
b, Frame, Wood, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a, Sup: Unc. Ret: Unc. AH: Attic
b, N/A
New
Single family
1
3
Yes
1482 ft2
0,0 ft2
215.0 ft2
0.0 ft2
0.0 ft2
R=O,O, 184.0(p) ft
R=II.O, BIl.O ft2
R=II.O, 90.0 ft2
R=30.0, 1482.0 ft2
Sup. R=6.0, 199.0 ft
12. Cooling systems
a. Central Unit
Cap: 34.6 kBtu!hr
SEER: 12.00
b. N/A
c, N/A
13. Heating systems
a. Electric Heat Pump
Cap: 34.6 kBtu!hr
HSPF: 7.60
b. N/A
c, N/A
14. Hot water systems
a. Electric Resistance
Cap: 4(}.0 gallons
EF: 0.88
b. N/A
c. Conservation credits
(HR-Heat retaveJy, SoIar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-MuItizone cooling,
MZ-H-MuItizone heating)
Glass/Floor Area: 0.15
Total as-built points: 22611
Total base points: 22666
PASS=-~
PREPARED
DATE:
I hereby certify that this buildin ,as des' ned, is in
compliance with the Florida Energy Code.
OWNER/AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGa~ (Version: FLReps v3.22)
F.ORM'sOOA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , ZEPHYRHILLS, FL,
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points
.18 1482.0 25.78 6877.1 Double, Clear W 1.0 6.0 60.0 47.65 0.97 2774.0
Double, Clear E 1.0 6.0 60.0 52.66 0.97 3065.8
Double, Clear E 1.0 6.0 20.0 52.66 0.97 1021.9
Double. Clear E 6.7 6.0 24.0 52.66 0.50 634.1
Double, Clear S 1.0 6.0 24.0 39.98 0.95 908.7
Double, Clear S 8.0 6.0 24.0 39.98 0.53 508.3
Double. Clear S 8.0 2.0 3.0 39.98 0.48 57.0
As-Built Total: 215.0 8969.'
WALL TYPES Area X BSPM = Paints Type R-Value Area X SPM = Points
Adjacent 90.0 0.70 63.0 Frame, Wood, Exterior 11.0 1311.0 1.90 2490.9
Exterior 1311.0 1.90 2490.9 Frame, Wood, Adjacent 11.0 90.0 0.70 63.0
Base Total: 1401.0 2553.' As-Built Total: 1401.0 2$53.9
DOOR TYPES Area X BSPM = Paints Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior IIl8UIated 40.0 4.80 192.0
Exterior 40.0 4.80 192.0
Base Total: 40.0 112.0 As-Built Total: 40.0 192.0
CEILING TYPES Area X BSPM = Pojnts Type R-Value Area X SPM X SCM = Paints
Under Attic 1482.0 2.13 3156.7 Under Attic 30.0 1482.0 2.13 X 1.00 3156.7
Ba.. Total: 1482.0 3156.7 As-Built Total: 1482.0 3156.7
FLOOR TYPES Area X BSPM = Paints Type R-Value Area X SPM = Paints
Slab 184.O(p) -31.8 -5851.2 Slab-On-Grade Edge InsuIatlon 0.0 184.0(p -31.90 -5869.6
Raised 0.0 0.00 0.0
Base Total: -5851.2 As-Built Total: 184.0 -5889.8
INFIL TRATlON Area X BSPM = Points Area X SPM = Points
1482.0 14.31 21207.4 1482.0 14.31 21207.4
EnergyGaugeGD DcA Form 600A-2001
EnergyGaugee/FIaRES'2001 FLRCPB v3.22
F.ORM SOOA-2001
SUMMER CALCULA liONS
Residential Whole Building Performance Method A - Details
t ADDRESS: , ZEPHYRHIUS, FL,
PERMIT #:
BASE AS-BUlL T
Summer Base Points: 28135.9 Summer As-Built Points: 30210.3
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(OM x DSM x AHU)
30210.3 1.000 (1.087x1.150x1.10) 0.284 1.000 11804.5
28135.9 0.4266 12002.8 30210.3 1.00 1.375 0.284 1.000 11804.5
EnergyGauge.... DCA Form 6OOA-2001
EnergyGaugeelFlaRES'2001 FLRCPB v3.22
F.:ORM .600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
J ADDRESS: , ZEPHYRHILLS, FL,
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BWPM = Paints Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point
.18 1482.0 5.86 1563.2 Double. Clear W 1.0 6.0 60.0 5.16 1.00 310.1
Double, Clear E 1.0 6.0 60.0 4.52 1.01 273.5
Double, Clear E ' 1.0 6.0 20.0 4.52 1.01 912
Double, Clear E 6.7 6.0 24.0 4.52 1.18 128.4
Double, Clear S 1.0 6.0 24.0 2.65 1.01 64.0
Double. Clear S 8.0 6.0 24.0 2.65 2.05 129.9
Double. Clear S 8.0 2.0 3.0 2.65 2.29 182
As-Built T 0181: 215.0 1015.2
WALL TYPES Area X BWPM = Paints Type R-Value Area X WPM = Paints
Adjacent 90.0 1.80 162.0 Frame, Wood, Exterior 11.0 1311.0 2.00 2622.0
Exterior 1311.0 2.00 2622.0 Frame, Wood, Adjacent 11.0 90.0 1.80 162.0
Base ToIaI: 1401.0 2784.0 As-Built Total: 1401.0 2784.0
DOOR TYPES Area X BWPM = Paints Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Exterior Insulated 40.0 5.10 204.0
Exterior 40.0 5.10 204.0
Base ToIaI: 40.0 204.0 As-Built Total: 40.0 204.0
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 1482.0 0.64 948.5 Under Attic 30.0 1482.0 0.64 X 1.00 948.5
Base Total: 1482.0 948.5 As-Built Total: 1482.0 948.5
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 184.O(p) -1.9 -349.6 Slab-On-Grade Edge Insulation 0.0 184.O(p 2.50 460.0
Raised 0.0 0.00 0.0
Base Total: -349.6 As-Built Total: 184.0 460.0
INFIL TRA liON Area X BWPM = Points Area X WPM = Paints
1482.0 -0.28 -415.0 1482.0 -0.28 -415.0
EnergyGauge4P DCA Form 600A-2001
EnergyGaugee/FIaRES'2001 FLRCPB v3.22
E-:>RM ,600A-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
J ADDRESS: , ZEPHYRHILLS, FL, PERMIT #:
BASE AS-BUll T
Winter Base Points: 4735.1 Winter As-Built Points: 4996.7
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Paints Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(OM x DSM x AHU)
4996.7 1.000 (1.078 x 1.160 x 1.11) 0.449 1.000 3114.6
4735.1 0.6274 2970.8 4996.7 1.00 1.388 0.449 1.000 3114.6
EnergyGauge TU DCA Form 6OOA-2001 EnergyGaugeelFJaRES'2001 FLRCPB v3.22
F.ORM .600A-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , ZEPHYRHILLS, FL,
PERMIT #:
BASE AS-BUlL T
WATER HEAnNG
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2564.00 7692.0 40.0 0.88 3 1.00 2564.00 1.00 7692.0
As-Built Total: 1692.0
CODE COMPLIANCE STATUS
BASE AS-BUIL T
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points Points Points Points Points Points
12003 2971 7692 22666 11805 3115 7692 22611
I
PASS
I
EnergyGaugeTM DCA Form 600A-2001
EnergyGau~FIaRES'2oo1 FLRCPB v3.22
FORM 500A-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
J ADDRESS: , ZEPHYRHILLS, FL,
6A-21INRL TRATION REDUCTION COMPLIANCE CHECKLIST
PERMIT #:
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACnCE CHECK
Exterior Wrndows & 0001$ 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area' .5 cfmIsq.ft. door area.
Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windowsIdoors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & topJbottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is instaHed that extends
from, and is sealed to the foundation to the toD Dlate.
Floors 606.1.ABC.12.2 Penetrations/openings >118" sealed unless backed by truss or joint members.
EXCEPTION: Frame fIool$ where a continuous infiltration barrier is instaUed that is sealed
to the perimeter, penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys. cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is seated at the Derimeter at Denetrations and seams.
Recessed Ughting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
sealed box with 1 fZ' clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned $Oace tested.
MuIti-story Houses 606. 1.ABC. 1.2.5 Air barrier on Derimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors. dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requiremems in Table 6-12. Switch or clearly marked circuit
breaker (electric) or cutoff (gas) must be provided. External or built-in heattraD reauired.
Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial poo/s
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons Der minute at 80 PSlG.
Air Distribution Systems 610.1 All ducts. fittings. mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls 607.1 Separate readilv accessible manual or automatic thermostat for each SYStem.
Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 600A-2001
EnergyGauge4DlFlaRES'2001 FLRCPB v3.22
ENERGY PERFORMANCE LEVEL (EPL)
DISPLA Y CARD
ESTIMATED ENERGY PERFORMANCE SCORE. = 83.1
The bigher tbe score, tbe more efficient tbe bome.
1, New construction or existing
2. Single family or multi-family
3. Number of units, if multi..family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft')
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SHGC - single pane
d. Tint/other SHGC - double pane
8. Floor types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Frame, Wood, Exterior
b. Frame, Wood, Adjacent
c. N/A
d. N/A
e. N/A
10, Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Attic
b. N/A
I , ZEPHYRHILLS, FL,
New
Single family
1
3
Yes
1482 ft2
0.0 ft2
215.0 ft2
0.0 ft2
0.0 ft2
R=O.O, 184.O(p) ft
R=l1.0, 1311.0 ft2
R=11.0, 90.0 ft2
R=30.0, 1482.0 ft2
Sup. R=6.0, 199.0 ft
12. Cooling systems
a. Central Unit
Cap: 34.6 kBtuIhr
SEER: 12.00
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 34.6 kBtu/hr
HSPF: 7.60
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 40.0 gallons
EF: 0.88
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Who1e house fan,
PI' -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*N01E: The home's estimated energy performance score is only available through the FLAlRES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EP A1DOE EnergySfa?M designation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site atwww.fsec.ucf.edufor
iriformation and a list of certified Raters. For iriformation about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 850/487-1824.
EnergyGauge@ (Version: FLRCPB v3.22)
-..
~~
~~
t'
~~ t
~
~
~
~ ~1~ ~
~ ,
~\\D r
"
f
.l
I
,
)
~
-.
~
~
'\~ ~
"'~-
'_ t
~~
~
'::'t..
?-
'n
I b
~-
I
-)
~ I fii (}j c:: I m ;:::0. JJ '-' ~
J: m )> );! :D C )> m:;E
\..>J m a 0 z -I JJ F
"'~ :D " r < Zz ~
~ r 0 0 Z -im m
o~. -2' ~ m ~ z "TI 0 mJJ JJ I
m -I "TI G)
~" m m [J) m JJ...... )>
-I -I m [J)
ma m :D m ~ m )> () !
aO :0 :D ~ a ()
o~ ~ () a :-l
~" --. m ()
"hi m JJ Z
r-l m p
mm (J) )
iT! 0 (J)
OOJ ~ ril
-<
:D
~ 0 0 0 ~ ~O ~
~ ~ J
z
0 (')
m
N=i III
I c
~ ~ m-< (f) )
~O z
) m
~ ~." 1'J
1l
3:N :D
~ 0
rm 0 )
~ In.,, c
(')
;,:r: ji!
N ~ r-< Z
o \ 0 ~. 0:0 r
(g~ :D ~:r: (II J
0 ~r= c:.i
~~ m
:D r- j
c;) );! ~ '"
\ CJ) 10
<: " 8
m ~ m
z z (II ')
21"<::: OJ I I I I I I ~ 0 ~ 0 0 a ~
-< ~ -C
(II
0 ~ [J) ~ m J c:.i 0
\~ c a m .:,
-I :D ~ '-t ;;; OJ
!I: c ~ c z a =i ~ m m .:, ')~
(ij ~ !I: m p =i -< :D :D ~ ~
p C 'V -< c;) '"
c: 0 0 m
0 z en "TI ~ ~
% -I ~ c:
~ ~ ~ z :)
:D ~ ~
CO) !I:
m 0
III c: 0'
z
j: -I
,)
.-~--~--"~'---'----- ~ ----~_..._-
-
Q a :D Z -I [J) (J) ~ JJO ~
J: m [J) c: J: m
J: m )> );! :D C )> m:;E
"'~ m a 0 z -I JJ F Zz ~
:D " ~ F 0 < m
0 Z -im
O:D ~ ~ m ~ z "TI 0 mJJ JJ I
~" m iT! m [J) "TI m G)
-I :D -I m [J) JJ...... )>
ma m m ~ m )> ()
aO :D :D ~ a ()
O~ () a :-l
~" m ()
"hi m JJ Z
-. m
r-l - p
mm (J) ')
iT! 0 \ (J)
OOJ
-< ril
~\ 0 :D
0 0 0 0 0 "TI
g
. ~ )
~ I Z
0 (')
m
N=i III
C
m-< (f)
~O Z
m
K ~." 1'J
1l
" n. 3:N II
~ 0
rm 0 )
/:? In.,, c
~ ()
~ -:r: _iiI
~ f!-< z
0 ~ 0 0:0 r
:D :D ~:r:
0 0 ~ t (II ')
m ~ m c_ c:.i
:D :D >r- j \-._-
c;) \ );! r- '"
~ " CJ) 10
~ m 8
z z (II ')
~21 ~ OJ I I I I I I ~ 0 ~ 0 0 ~ ~
-< f- a .s.
~ (II
~ 0 z ~ [J) m ( c:.i
c a m ~ j 0
-I :D ~ OJ
!I: c ~ c z a =i OJ m m '" -)~
(ij ~ !I: m p =i -< i!) :0 :D -::> ~ 0
p 0 'V -<
c: 0 0 m '"
0 z en "TI -:)
~ -I ~ c:
S ~ z th f]
:D ~
CO) !I:
m -I 0 ,'t \J\
c:
III Z
j: -I ~ "\-'
85/25/2005 17:09
9725424139
:;IMF''::U~ ENGINEERH1G
PAGE 01
Strong-Tie
SIMPSON
TO!
May 25, 2005
Village Square Builders, Inc.
Attn: Lance Smith
6212 Abbot Station Drive
ZephyrhiHs~ FL 33541
By Fax: 813-782-3321
RE: Multiple Connectors
Dear Mr. Smith:
This letter is written in response to Our phone conversation today and your fax sent today
to Sam Hensen.
A licensed engineer has recommended that a Simpson Strong- Tic FGTR and MGT be
combined to provide the required uplift resistance on a rooftruss. Simpson Strong-Tie
has not evaluated this combination of products, so we cannot offer a recommendation on
whether this is sufficient or not.
However, if the engineer has evaluated the connection and detennincd that this is
adequate, it i,s acceptable to Simpson Strong- T;e that he makes that detcnninatlon. The
engineer will have to take full responsibility for the connection, though.
If 1 can be of fllrther assistance, please feel free to contact me at 1-800-999u5099.
Sincerely,
/2~'L~.U~l~J
Simpson Strong-Tie Company
Randall Shaekelford~ P.E.
';1
(l~ ~~
cc: J. Gilstrap
R. Gaines
Simpson Slrnllll-Tje (;umpaIlV. II1G. 2221 Country Lane McKinney, TX 75069 Phone 972542,03213 Fa)(: 972,5425379 www.strongtl8.com
/~
AfiiCfc:A 'Y. ENG INEEfiiC ING INO.
STRUCTURAL ENGNEERS
May 23, 2005
Randy Watson Designs, Inc.
13821 U.S. Highway 98 By-Pass
Dade City, Florida 33525
Attention: Randy Watson
Re: Santana Residence - Silver Oaks Village
Arkay Engineering, Inc. Job # 8415
Dear Randy:
This letter is a written confirmation of our telephone conversation
regarding some field revisions to the above referenced project.
I have reviewed the photographs of the
the front and rear porches. Both of
structurally acceptable, as constructed,
past the posts. If desired, the posts
materials.
"cantilevered" roof beams on
these porch conditions are
with the beams cantilevering
can be padded out with 2 by
Further, the beam to post connection can consist of one Simpson "AC4"
connector and one Simpson "HTS16 II twist strap or one Simpson "LSTA24"
strap tie at each post.
Also, the 40'-8" 3 ply girder truss can be anchored to the block with
a one Simpson "FGTR" Face Mount Girder Tiedown - Retrofit connector
and one Simpson "MGT" Heavy Girder Tiedown at each bearing location.
If you need any further assistance with these items, please give me a
call at the office.
5600 US HWY. Cl6 NORTH - SUITE #5 LAKELAND, FLORIDA 3360Q
PHONE: 663-653-2711 FAX: 663-616-2116
STATE OF- FLORIDA CERTIFICATE OF AUTHORIZATION # EB6347
RICHARD L. KIDDEY, P.E. - FLORIDA LICENSE # 372Cl6
CONTRACTOR H~ 999999
j\I{lf>1E:: VII:.I...AGE SW.JM~E BUILl)FR~;
ADDR~ 6449 ASHEVILLE DR
C/S1= ZEPHYRHILLS~ FL
L~NTRAL PERMITTING
PASCO COUN1Y~ FLORIDA
DATE~ 06/30/05 TIME: 15~33
PtlGE :: 1. OF :I.
ISSUE OFFICE:: D
RECEIPT NUMBR: 00833254
OFFICE: DADE CITY
FOF~::
CONTRACTOR: 999999
TOTAl... AMOUNT:
(..CCNT COMPNY ACCOUNT CENTEF~
114 B450 - 363000 - 2
CHEU:: # 19~56
CITY OF Z"-HH..L.S fL:;/OO
29_42
AMOUNT DESCRIPTION/PERMT DATA DR/CR
29.42 ****** SOLID WASTE FEE 60
RECEIVED BY
-M~:,:.'c:::.......___.._....__...._....._.................... ....__...._.