Loading...
HomeMy WebLinkAbout05-4149 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 4149 Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 4149 MECHANICAL FIRE SUPPRESION SYS COMMERCIAL Address: 5130 ALL BLVD ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 2,000.00 4/26/2005 40.00 40.00 4/26/2005 Phone: RECHARGE & REALIGN APPLIANCE NOZZLE COVERAGE Name: LUPTON Address: 5130 GALL BLVD ZEPHYRHILLS, FL. 33542 REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances NO OCCUPANCY BEFORE C.O. ~. CTOR SIGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF Z~!:'t1:t~n.J.~~u ...----- BUILDING DEPARTMENT 5335 8TH st, Zephyrhi11s, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECEIVED PHONE GONTACT FOR PERMITTING OWNER'S NAME L LA jJ I-~ /} JOB ADDRESS,S- / 30 6-4/( ISf (/J PHONE 2-ePAf-yj, Iff, F /. , ) J S-C/Cl LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION IOBTAIN FROM PROPERTY.TAX NOTICE) PARCEL ID # o SIGN o MOVE o ALTERATION o DEMOLISH ~EPAIR o INSTALL WORK PROPSED: ONEW CONSTRUCTION o ADDITION PROPOSED USE: OSGL FAMILY DWELLING o COMMERCIAL OMULTI-FAMILY o INDUSTRIAL 0# OF UNITS o SWIMMING POOL o MOBILE HOfll o OTHER c=J RESTAURANT & HEALTH DEPARTMENT AP~ROVAL DESCRIPTION OF WORK l<eci_Q..~ a~ f2e oJ;:!) i/'.. frlPlla'.tce /Vo'Z-Z: Ie ~CJver;]:ff'~ BUILDING SIZE SQUARE FOOTAGE HEIGHT RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. & (1) SET ENERGY FORMS. FORMS. c-p~n{! f<! -Q. V " V\. 7~ 7-6<g7- J~~S- o BUILDING $ VALUATION OF TOTAL CONSTRUCTION o GAS o ROOFING AMP SERVICE 0 Progress Energy 0 W.R.E,C. 11 GI (~1 $ VALUATION OF MECHANCIAL INSTALLATION o SPECIALTY 0 OTHER o ELECTRICAL o PLUMBING ~ECHANICAL TYPE OF CONSTRUCTION: 0 BLOCK o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAO YES 0 NO COMPANY BUILDER SIGNATURE STATE CERT OR REGIST # ****************************************************************** ELECTRICIAN COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** PLUMBER COMPANY SIGNATURE STATE CERT OR REGIST # ******************************************************;Z;********* MECHANICAL ~ / COMPANY F"r,e.. S y, Vl(S ,'^C-. SIGNATURE ~~ ~ ~/ . STATE CERT OR REGIST # ***************************************************************** OTHER COMPANY SIGNATURE STATE CERT OR REGIST # A. NOTI~E OF DEED RESTRICTIONS Th~ undersigned understands that this permit may be subject to ~deed restrictions" which may be more restrictive than city regulations. The undersigned assumes responsibility for compliance with any appiicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, 'they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may. be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhi11s Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign po~tions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, yOu are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indica~i6n that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C.. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, haye been provided with a copy.of ~Florida's Construction lien Law - Homeowner's ,Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction; zoning, and land development. Appliqation is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may appiy to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells; Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement :[ also certify that, .if fill material is to be used in Flood Zone "A" or "A, etc.';, it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall.be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the techni~al codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permi~ issued shall become invalid unless the work authorized by such permit is commenced w~thin six months of issuance, or if work authorized by the permit is suspended or abandoned,for!a period of six months after the time.the work is commenced. One 90 day extension of t~me may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to 'the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT .MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS 'TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCIN~, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCE~ENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT. SIGNATURE: CONTRACTOR SIGNATURE: OWNER OR AGENT acknowledged , 2CL- STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _day of by STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _ day of by acknowledged , 20_ (name. of person acknowledged) o who is personally known to me, . or (name of person acknowledged) [1ho is personally known to me, or o who has produced (type of identification) and wliod did Odid not take an oath. o who has produced (type of identification) and who Odid [}:lid not take an oath Signature of person taking acknowledgment Signature of person taking acknowledgement Name typed, printed or stamped Name typed, printed or stamped /Lj \.. ~ ~ '- ~ -- 1 Q )--. -- r\ x ... ~ --... ~ >.... ~ ~ s: \$ (J ~ ~ .~ ...... "- <X:> "- \-J) " ~ F ~ ~ J:: ~ \i~~ ~ ~ ~ <; ~ .~..... (f) 1-t3 .,. ~ 4- '^ D{i ~ J .:}..-.J ~~ x.~ "'- ::- \... ~ ~ ::r-- ..... - ~v ~- ~ )<."\$ ~ -( (~ \j ~ - ~ -~ qj ~ '- ~ '- - X. \.L I)- - '- ...)--.:: ~ .~::r-.~ '- -- \~ i ~ x ~x ~ x~x v ~ x\./ "'^' ~ -^-.,. ~ ~ '^3 ~ ~ ~'> ~== oS ..c:e 'i ~ ] E ~ ~::c Q.. e-'B 5 ~ o u .=~ U G) = -G)C =a ~ >.- ..c: .u ~ U U) :.= ~ G) etlO 8: ~ oS ~~~cfd :aoS.{!~ ~ .s ~ . fi: \J C{) o ~ '"' . t. ~....... " -~ i::.. 8~ 't ~ t1J ...J \t ~d~ VJ:C ~ ~" --~ ""'l Z?; ~ ~ o~ ,~ ~ t:\.c ~ \~ uUJ'-....... 'Z I"Y' N . ~ ~ - ~ \~ CI) ~ \~ ~ z - - , - ;~U- ~ oc; \1\- - (j)-==~ C .-$-L O~)- -+ l Q~cf 5 M v --1~N .", ~ <J -J- ~ - VJ -0 }XJ -J ~ f"-. cXJ ~ ~ I ~ M M I ~ ~ f'F\ M \J c:::- r......... - -- V) lI- ~ ~ ~ f'-. tl ~ ~ :J ~J-~ A (\ \J) ~~ V~~ L _ ,- <:0 --+- 1.l...... CL \f) ( <2) +'- J ~ <}.J+ -+-0 e \5 0_ l.. --1- <J C L ~ t- \j LL . jj', DESIGN ;". R-102 RESTAURANT': INSTALLJ)'fION .,. <;~~. FIRE SUPPRESSION RECHARGE ANE).\ ' SYSTEM MAINTENANCE (Standard UL 300 Listed) MANUAL . ""ii, , .. ANSUL@ . ~& ~ ,r.; I .1 i i, II 1 ":'J ,..-...... 4, 4ft .. ,.. .. ... - - - - _. - - - _. - ,- - - - - ~ JIll'" .:.. /' . '';';;'?i&t.> , ""-~, II'. o . . . ,. , , . -. :~~'I',.' .,;.', ,,:'~ ~.. . h. ',,_,'.~ .-~~~., . I' {. ; ....~ ' ':' 1'~" , t. , ,o.';,.i: '",:'.~~k.''(: 'l:_,"j,Fi.~;-~,...~: ::;:-"!(7~ . ...!J.:~~l< ~...~' ..~<';:i".~' , .., ....... .~. .~;.;..-~...l " ,.. J . _ ...... 0',':.. :;,", lL:'~ f-.. ;.(., _: . w~;,,'" ',. .~ .. ~.. " # -.. .... j. , 'i SECTION IV - SYSTEM DESIGN UL EX. 3470 11:1-94 Page 4-2 NOZZLE PLACEMENT REQUIREMENTS (Continued) Duct Protection (Continued) The 1W and 2W nozzles will protect the following: 3. Single Nozzle (2W) Duct Protection: One 2W nozzle will protect ducts with a maximum perim- eter of 75 in. (190.5 em) or a maximum diameter of 24 in. (61 em). The nozzle must be installed 2-8 in. (5-20 em) into the center of the duct opening and positioned as shown in Figure 4. i 2-8 IN. (5-20 emJ( FIGURE 4 4. Single Nozzle (2W) Transition Protection: One 2W nozzle will protect transitions at the point where the perimeter of 75. in. (190.5 em) or the diameter of 24 in. (61 em) or less begins within that transition. The nozzle must be placed in the center of the transition opening where the maximum perimeter or diameter begins as shown in Figures 5 and 6. MODULE PERIMETER NOT MORE THAN 15. IN. (190.5 em) FIGURE 5 MODULE DIAMETER NOT MORE THAN 24 IN. (61 em) FIGURE 6 5. Dual-Nozzle Duct Protection: Two 2W nozzles will protect ducts with a maximum perim- eter of 150 in. (381 em) or a maximum diameter of 48 in. (122 em). The nozzles must be installed 2-8 in. (5-20 em) into the duct opening and positioned as in Figure 7. FIGURE 7 NOTICE In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 em) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (20 em) in this way will not void the UL listing of the system. , ..~ 'r;' rll Sf;CTION IV - SYSTEM DESIGN UL EX. 3470 11-1-94 Page 4-8 .,0 1 " NOZZLE PLACEMENT REQUIREMENTS (Continued) Plenum Protection (Continued) ,;~,...I,.. ~> ~ . j i 11 ." i' I i ., i ' t : ~ ~ 'j !" NOZZLE TIP MUST BE WITHIN THIS AREA FIGURE 26 1 N NOZZLE - PART NO. 56930 One 1 N nozzle will protect 8 linear feet (2.4 m) of single filter bank plenum or two 1 N nozzles will protect 8 linear feet (2.4 cm) of "V" bank plenum. In either application, the nozzle(s) must be mounted in the plenum, 2to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The filter height must not exceed 20 in. (51 cm). See Figure 27. il r,! .' 8 FT. (2.4 m) MAXIMUM ~i 1~ ~i I :1 '1 I, 1:' ,j II ~ /1~> 2-4IN. (5-10 em) , I" ./ 2-4 IN. (5-10cm) I j FIGURE 27 Exception: When the plenum chamber containers filters that do not exceed 10 in. (25.4 cm) in height and the 1 N nozzle can be installed at the intersecting center lines of both filter banks and not exceed the 2-4 in. (5 to 10 cm) distance from either filters, a single 1 N nozzle can be used. See Figure 27a. 10 IN. (25.4 em) MAXIMUM FIGURE 27a NOTICE If 1 N nozzle coverage does not exceed 7 linear ft. (2.1 m), the nozzle can be mounted 2 to 6 in. (5-15 cm) from the face of the filter. For a plenum, either single or "V" bank, with a linear extension longer than 8 feet (2.4 m), each bank may be protected using one 1 N nozzle every 8 ft. (2.4 m) or less depending on the overall length of the plenum. See Figure 28. The nozzles may point in the opposite directions as long as the entire plenum area is pro- . tected, and the 8 ft. (2.4 m) limitation is not exceeded. See Figure 29. The nozzle positioning shown in Figure 30 is not an accept- able method of protection because the plenum area directly. under the tee is not within the discharge pattern of either nozzle. FIGURE 28' .J)ECTION IV - SYSTEM DESIGN UL EX. '3470 3-15-95 Page 4-10.2 ~ NOZZLE PLACEMENT REQUIREMENTS (Continued) Multiple Nozzle Fryer Protection - 2-Flow High Proximityl 2-Flow Low Proximity (Continued) FRYERS WITH DRIP BOARDS (Continued) To properly protect this hazard with multiple nozzles, divide the surface area into modules not exceeding 294 sq. in. (1897 sq. cm) (cooking area plus drip board area) and 210 sq. in. (1355 sq. cm) of fry pot only. When dividing into modules, the longest side of each module must not exceed 21 in. (53 cm). See Figure 33b. THIS IS TOTAL MODULE AREA WITHOUT DRIP BOARD 21 IN. (53 eml MAXIMUM DIMENSION (COOKING AREA NOT TO EXCEED 210 so. IN. (1355 sq. em) MAXIMUM THIS IS TOTAL MODULE AREA WITH DRIP BOARD 21 IN. (53 em) MAXIMUM DIMENSION INCLUDING DRIP BOARD (COOKING AREA INCLUDING DRIP BOARD NOT TO EXCEED 294 SO. IN. (1897 sq. em) MAXIMUM FIGURE 33b The R-102 system uses two different style nozzles for this protection. 1. High Proximity Applications: 27 to 47 in. (69 to 120 cm) above the top surface of fryer. See Figure 33c. The 230 Nozzle (Part No. 418117) is used for high prox- imity applications. The nozzle tip is stamped with 230, indicating that this is a two-flow nozzle and must be counted as two flow numbers. When using this nozzle for fryer protection, the nozzle tip must be positioned anywhere along or within the perimeter of the area it is protecting and aimed at the mid point of the respective modular area. 2. Low Proximity Applications: 20 to 27 in. (51 to 69 em) (above top surface of fryer. See Figure 33c. The 245 Nozzle (Part No. 418118) is used for low proximity applications. The nozzle tip is stamped with 245, indicating that this is a two-flow nozzle and must be counted as two flow numbers. To protect each area, the nozzle tip must be located within the perimeter of the area it is protecting and aimed at the mid point of the respective modular area. See Figure 33c. ~ ~ POSITION NOULE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE AREA IT IS PROTECTING AND AIM AT MIDPOINT OF THAT MODULAR AREA. .-- ___ ___ 1'- "- "- rC I "- I '....... I " .-- I I"""'y"" I : I I k I I It I I I I I I I I I I I I 230 NOZZLE - 27 IN. TO 47 IN. (69 TO 120 em) ABOVE TOP SURFACE OF FRYER 245 NOZZLE - 20 IN. TO 27 IN. (51 TO 69 em) ABOVE TOP SURFACE OF FRYER . . . . . . See Figure 33d for two examples of modularizing larger drip board fryers. EACH MODULE MUST NOT EXCEED 294 so. IN. (1897 sq. em) I 21 IN. L FIGURE 33c 28 IN. (71em)i 14 IN. (35.6 em) I -. I AIM NOZZLE I AIM NOZZLE AT MIDPOINT AT MIDPOINT OF MODULE I OF MODULE + I +- I I . DRIP BOARD I DRIP BOARD I' 15 IN. ~~=J EXAMPLE ONLY 30 IN. EACH MODULE P (76 em) I MUST NOT EXCEED 15 IN. ~8~i~q.I~;.,) (38 em) -, f 1 (35.6 em) --1 19518 IN. (49 em) L ~ I I MIDPOINT I MIDPOINT + I + I . I DRIP BOARD I DRIP BOARD EXAMPLE ONLY FIGURE 33d SECTION IV. - SYSTEM DESIGN UL EX. 3470 3-15-95 Page 4-10.4 ~ NOZZLE PLACEMENT REQUIREMENTS (Continued) ~ Single Nozzle Fryer Protection - 3-Flow High Proximityl 2-Flow Low Proximity If the fryer does not have a drip board, the maximum hazard size is 19 1/2 in. x 19 in. (50 x 48 cm), or the fryer can have a maximum area of 370 1/2 sq. in. (2390 sq. cm) with the lon- gest side not to exceed 19 1/2 in. (48 cm). If the fryer has a drip board, the maximum hazard size is 25 3/8 in. x 19 1/2 in. (65 x 50 cm) or the fryer can have a maximum area of 495 sq. In. (3194 sq. em) with the longest side not to exceed 25 3/8 in. (65 em). The nozzle must be aimed at the midpoint of the hazard area. The R-102 system uses two different style nozzles for the pro- tection of fryers. 1. High Proximity Applications: 21 in. to 34 in. (53 x 86 cm) (34 in. (86 em) maximum diagonal) above the top surface of fryer. See Figure 33h and Figure 33i. The 3N nozzle, Part No. 76782, is used for high proximity applications. The nozzle tip is stamped with 3N, indicating that this is a three-flow nozzle and must be counted as three flow numbers. When using this nozzle for fryer protection, the nozzle tip must be positioned anywhere along or within the perimeter of the maximum hazard area and aimed at the midpoint. See Figure .33h and 33i. The maximum distance from the midpoint of the fryer to the nozzle tip is 34 in. (86 em). See Figure 33h and 33i. 3N NOZZLE TIP 34 IN. (B6 em) POSITIONED MAXIMUM DISTANCE TO MIDPOINT ANYWHERE ALONG OR OF HAZARD AREA WITHIN PERIMETER~ OF COOKING SURFACE AND AIMED AT THE MIDPOINT ~~~L____......_ .::;-- I -_-......: "./..:: I ~/--~: I.................. ......., ........-1- /T......;>t.""'~"'<::" I '">--.....-"""'... 1/_/ ~ ...... -~- ~ I< - T ~'t' __ I -- - I i;' I ---1---~ roV I ~ I ~. Int I MAXIMUM COOKING AREA. INCLUDING DRIP BOARD, MUST NOT EXCEED 495 SO. IN. (3194 sq. em) 25 318 IN. (65 em) MAXIMUM LONGEST SIDE 34 IN. (86 em) MAXIMUM 1 21 IN. (53 em) MINIMUM L 34 IN. (B6 em) MAXIMUM DISTANCE TO MIDPOINT OF HAZARD -.J FRYER WITH DRIP BOARD rrr,1 IRF 1111 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED AT THE MIDPOINT 34 IN. (B6 em) MAXIMUM -t 21 IN. (53 em) MINIMUM L FRYER WITHOUT DRIP BOARD .., ~ MAXIMUM COOKING AREA MUST NOT EXCEED 370 1/2 SO. IN. (2390 sq. em) 19 1/2 IN. (50 ern) MAXIMUM LONGEST SIDE 34 IN. (86 em) MAXIMUM DISTANCE W "]'" '" "~"' FIGURE 33i I Ii Ii . ~\ I , 1\ 'I I 1< I -: I; I] . . . . . . . ~ l ,.. ~ ,. ~ . . .. NOZZLE PLACEMENT REQUIREMENTS (Continued) Multiple Nozzle Fryer Protection - 3-Flow High Proximityl 2-Flow Low Proximity (Continued) FRYERS WITHOUT DRIP BOARDS (Continued) 2. Low Proximity Application: 13 to 16 in. (33 to 41 cm) above top surface of fryer. See Figure 33t. The 290 Nozzle, Part No. 418120, is used for low proximity applications. The nozzle tip is stamped with 290, indicating that this is a two-flow nozzle and must be counted as two flow numbers. When using this nozzle for fryer protection, the nozzle tip must be positioned over the midpoint of the respective modular area + 1- 3 in. from the midpoint along the lon- gest side of the module and + 1- 1 in. from the midpoint along the shortest side of the module and aimed at the mid- point. See Figure 331. 290 NOZZLE TIP MUST BE POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR AREA ;f; 3 IN. (7.6 em) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE MODULAR AND ;f; I IN. (7.5 em) FROM THE MIDPOINT ALONG THE -"'~.~ o~~~ ~;~~~'m' ""~" F'" -~:: -"" I I .......P< :.--:::- I ~ I - k _ _,'-,- I ' , k - '-, I I" I_~ I I r . . 1 . 16 IN. (41 em) MAXIMUM I MIDPOINT OF MODULE II FRYER WITHOUT DRIP BOARD FIGURE 33t II .. Range Protection The R-l02 system uses three different nozzles for the protec- tion of ranges. 1. High Proximity Application: 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. The high proximity application uses the 245 nozzle, Part No. 418118. The nozzle tip is stamped with 245 indicating this is a two- flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a cooking area of 672 sq. in. (4335 sq. em) with maximum dimensions of 28 in. x 24 in. (71 cm x 61 em). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 34 and 35. I I I I , I I SECTION IV - SYSTEM DESIGN UL EX. 3470 3-15-95 Page 4-11 REV. 1 28 IN. (71 em) T' 24 IN. (61 em) M~UM.......... _1""............MA~~~t 1_,.--- I '-,_, ;<.: I .........'>j I .............. I -..... I I ......'( I I, I I, I I I I I I I I I I I I I I I I I ~ 245 NOZZLE TIP LOCATION ., CENTER LINE OF COOKING SURFACE I [/1 f I I I t-11 I I 50 IN. (127 em) I MAXIMUM HEIGHT I OF 245 NOZZLE TIP I I 40 IN. (102 em) I I MINIMUM i I HEIGHT I OF 245 I I I NOZZLE TIP I I I I I I I FIGURE 34 ~ ~ ~ NOZZLE PLACEMENT REQUIREMENTS (Continued) ~ Griddle Protection The R-1 02 system uses four different nozzles for the protection of griddles. One of the applications requires a one-flow nozzle and three of the applications require a two-flow nozzle. One-Flow Griddle Protection 1. High Proximity Application: 35 in. to 40 in. (89 to 102 cm) above the cooking surface. This high proximity application uses the 1 N nozzle, Part No. 56930. The nozzle tip is stamped with 1 N indicating this is a one- flow nozzle and must be counted as one flow number. One 1 N nozzle will protect a cooking area of 1080 sq. in. (6968 sq. cm) with the maximum longest side of 36 in. (91 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the cooking surface. See Figure 40a and 40b. II I I I I I NOTICE When using this type of griddle protection, only 5 flow numbers are allowed on a 1.5 gallon system and only 11 flow numbers are allowed on a 3 gallon system. I I r . SECTION IV - SYSTEM DESIGN UL EX. 3470 3-15-95 Page 4-14.1 30 IN. l' (76 em) 36 IN. (91 em) r= MAXIMUM "'-"', ~ _.-"- I .............. r<:: I "....., 'I , i '.....,1 />j 1 r- , I I I I I I I I I I I I r 1 I 1 I 1 I NOZZLE LOCATION h : l ~NSIl;EI~E~II~E~~~) )[' I I I OF COOKING SURFACE I It II -1 r 1'~ll. 40 IN. (102 em) I I MAXIMUM EDGE OF I I I 1 HEIGHT OF COOKING I I / I I 260 NOZZLE TIP SURFACE I I / I I 35 IN. (89 em) "'II I I MINIMUM I 1 I I HEIGHT OF II I ~~~ I I I I TIP II I I FIGURE 40a [ ~-r MIDPO:;~F---' I COOKING SURFACE --t I 1/ I I .- I I-- : L----__~_iJ IN NOZZLE LOCATED ALONG ANY SIDE OF GRIDDLE SURFACE WITHIN 0 - 2 IN. (0 - 5 em) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE COOKING SURFACE EDGE FIGURE 40b i'