HomeMy WebLinkAbout05-4417 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 4417 Permit Number: 4417 Issued: 6/10/2005 Permit Type: NEW SINGLE FAMILY DWELLING Class of Work: 1 01-NEW CONST/SFR Proposed Use: SINGLE FAMILY RESIDENTIAL Sq. Feet: Est. Value: Cost: 103,800,00 Total Fees: 7,929.95 Amount Paid: 7,929.95 Date Paid: 6/10/2005 Name: US HOME CORPORATI N Addr: 600 N WESTSHORE BLVD, STE 600 TAMPA, FL 33609 Phone: 813 854-4608 Lic: Work Desc: NEW SINGLE FAMILY DWELLING Address: 7616 WEEHAWKEN DR ZEPHYRHILLS, FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: CRESTVIEW HILLS Parcel Number: 35-25-21-0120-0000-0900 US HO ES CORP.lLENNAR 7616 WEEHAWKEN DR ZEPHYRHILLS, FL. 33542 Phone: WATER CONNECTION RESIDENl SCHOOL IMPACT FEE - 97,5% BUILDING FEE FIRE IMPACT FEE WATER METER RES 3/4" 419,00 MECHANICAL FEE 1.651,65 TRAFFIC IMPACT FEE 1% 798,00 RADON 273.00 POLICE IMPACT FEE 180,00 73,85 SCHOOL IMPACT FEE 2,5% 15.88 TRAFFIC IMPACT FEE 99% 20,76 PARK FEES SF 254,00 PUBLIC SAFETY 5% 11 . 42.35 1,572,12 769,56 26,35 .v6 / (,...L./ (( \ (\ \ \ 011 \ 1Y \~ ~ ./ ~ --0- L B DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED LINTEL PRE-METER WATER SHEATHING FRAME MISC SEWER MISC INSULATION WALL MISC MISC, MISC, INSULATION CEILING MISC, MISC, MISC, DRIVEWAY MISC. MISC, REINSPECTlON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade: (a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when inspection called (d) Work not ready for inspection when called (e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. ~RSSIGNATURE PERM. CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER MAR/31/2005/THU 11:40 AM ZEPHYRHILLS BUILDING FAX No. 813-780-0021 p, 002 CITY OF ZEPBYRHILLS PERMIT APPLICATION BUILDING DEPARTMENT 5335 8"0 St, Z..,phyrhi.11.s, FL 33542 813-780-0020 FAX: 813-780-0021 DATE Rli:CE IVED Le..A^OI..1 LJr 9;3 - 7{Pf} -5;1.77 e"fJ./l43$ <[,*3 -~ 7&1- 5J..-n Ii'HONE CONTACT FOR Ii'EPHITTJ:NG owNER'S NAME 1)5 tlolV\t.. CotfG~~lI.,-. JOB 1\DDRESS '7u/~ ~Ghffh/~~P? PHONE N BLOCK SUBDIVISION 1/; II $ PARCEL ID it LEGAL DESCRIPTIO~: WORK PROPSEO: PROPOSED CONSTRUCTION o ADDITION o ALTERAT IoN o DEMOLISH o REPAIR o INSTALL OSIGN USE~GL. FAM1LY o COMMERCIAL o MOVE DMULTI-FAMILY o INo..USTRIAL o It OF UNITS o SWIMMING POOL o MOBILE HOME DOTHER DWELLING c=J RESTAURANT & HEALTH DEPARTMEN: ~PROV~ ~ New sf(( j L1/1qole/: ~kk.f? ~#C; Z003 SQUARE FOOTAGE z,CJ 76 HEIGHT BUILDING SIZE DESCRI~XON OF WORK RESIDENTIAL:. ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING pLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1.) SET ENERGY FORMS. IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL .NEW CONSTRUCTION. M BUILDING o ELECTRICAL o PLUMBING o MECHANICAL PERMITS REQUESTED $ /09> 2/0 /' ~ 0 AMP SERVICE VALUATION OF TOTAL CONSTRUCTION W' o W.R.E.C, Progress Energy $ VALUATION OF MECHANCIAL INSTALLATION o OTHER o GAS 0 ROOFING D SPECIALTY TYPE OF CONSTRUCTION~BLOCK FINISHED FLoo~ ELEVATIONS BUILDER . SrGNA;O~ ELECTRIC:r.AN SIGNATURE 1i'L0000R SIGNATURE Ml!:CHANICAL SIGNATURE o FRAME o STEEL D OTHER IS PROJECT IN FLOOD ZONE AREAD YES ~O STATE CERT OR REGIST # ..******* *.***.**.****.******~..*...****.**.***.~ ~-"'.+ COMPANY ~~ P<l\~Lc ~e.J;i(: e RoO 1 LfSOl' ~ <./ **************************************.*.*************~*'k*****.*** STATE CERT OR REGIST . COM_ANY \)" \11-.( Lov~ pj"M~l,,~ STATE CERT OR REGIST ~ e F'c l4 ~ (.;).'1 ***.*****************~*:****1b***.**r.**.* COMPANY. f' "1 S 012 A <.... . STATE CERT OR REGIST .. C-A<-OS"O If! (:) OTHER ~r".~'~W"4""" ..... .~::.:;:,:. 'C: ;'F;;L:~ ~...... ... SIGNATURE V"~ - STATE CERT OR REGIST t CC -CoS799 / u.s. Homes Walden Grande 2003 Lot #90 SQ. FEET PRICE MAIN OR LIVING: 2,076 $ 50,00 OTHER AREA UNDER ROOF: $ 50.00 OTHER: $ - VALUATION $ 103,800,00 FEE SHEET $ 492,00 ADDRESS $ 30.00 DRIVEWAY $ 30,00 BUILDING: $ 798,00 CREDIT: $ - BUILDING LESS CREDIT: $ 798,00 ELECTRICAL: $ 117,93 PLUMBING: $ 99,50 MECHANICAL: $ 73.85 SUB-TOTAL $ 1,089.28 RADON: $ 20,76 TOTAL $ 1,110.04 SEWER: $ 1,616,00 WATER: $ 419,00 IRRIGATION: $ - TOTAL: $ 2,035.00 WATER METER:I $ IRRIGATION METER $ 180~00 I SUB-TOTAL $ 3,325.04 I 769,561 PARK IMPACT FEESI $ PUBLIC SAFETY IMPACT FEES POLICE $ 254,00 FIRE $ 273,00 5% $ 26.35 SIF'S: $ 1,694,00 97,5% $ 1,651,65 2,5% $ 42,35 T IF'S: $ 1 ,588,00 99% $ 1,572,12 1% $ 15,88 TOTAL: $ 7,929.95 , Florida Design Solutions, Inc. Structural Engineers 951 S. Orange Blossom Trail Apopka, FL 32703 Telephone 407-814-2125 Facsimile 407-880-2309 December 2, 2005 City of Zephyrhills County of Pasco Ref: Model: Lot # Address: Subdivision: US Home - Tampa Walden Grande 2003 82 7616 Weehawken Drive Crestview Hills US Home job # MKDA job# FDS# Permit# 15117 -52-0090 05-1459 200508899 4417 Dear Elissa, Based upon a telephone conversation with John Greene of US Home on 12/1/2005, we have reviewed the above referenced plans due to an as-built condition. The contractor installed a (2) 2XlO wi !12" flitch header between the foyer and bath #2 in lieu of the (2) 2X12 header called for in the plans, Based upon our structural review, we certify that this as-built condition is adequate and acceptable for the design loads of this project, If you have any further questions, please do not hesitate to call, Sincerely, , ,) {1V II--- \" ~^ M /l-..--- p,.- arl A. Brown, P ,E, FL. # 56126 12/212005 Michael J, Burden, P,E, FL. # 61628 12/2/2005 ... Florida Design Solutions, Inc. Structural Engineers 951 S. Orange Blossom Trail Apopka, FL 32703 Telephone 407-814-2125 Facsimile 407-880-2309 December 2, 2005 City of Zephyrhills County of Pasco Ref: Model: Lot # Address: Subdivision: US Home - Tampa Walden Grande 2003 82 7616 Weehawken Drive Crestview Hills US Home job # MKDA job# FDS# Permit# 15117-52-0090 05-1459 200508899 4417 Dear Elissa, Based upon a telephone conversation with John Greene of US Home on 12/1/2005, we have reviewed the above referenced plans due to an as-built condition, The contractor installed a (2) 2XlO w/ Yz" flitch header between the foyer and bath #2 in lieu of the (2) 2X12 header called for in the plans, Based upon our structural review, we certify that this as-built condition is adequate and acceptable for the design loads of this project, If you have any further questions, please do not hesitate to call. Sincerely, ,~1 ,1,) ~)" f#? ~ (7~ r- Car! A. Brown, P.E. FL. # 56126 12/2/2005 Michael J, Burden, P.E, FL. # 61628 12/2/2005 1,;'; .- ~ ..' _,I :1 !! ,., I , " \",1 , !'i iol:' ("T'/-I'fP^' j';';';'j 1 ! i ; , ~: !; ! ~ , ") '~'.:-:-'I::'~..( ot. oyo'Y' T"-'.... --- --'.-- --,--, '~'- --'~'-'-'--.- ;. ! r" 1" \ , , I r ~.. , i ~_ (t"'" JRN-26-2006 12:40 P.01 Architectu1'al Services a~d Engineering, .Inc. ..--- ' r-Ioridct '/4no S/llte RO:.ltJ !w L-utz. Flmida 335W 1-8'/3-94/3-2812 FAX; 1_S13_PAIJ4:iOltJ Floridn ~rrgin5Cring l/CIm.i~ CA 78/fJ rexS !: JUOO .'1Il(IfJ flood, ;;uitP. 1:374 Houston, Tex~3 770b6 ,_713-953-884Q FAX; 1_71396J-!lEl4D T"X(1.~ enj:i,u:eril'lg IIC'en.~e 95.,1 05 E-Mrul: offioB@ManJ~c:o/'f1 De:ii!:flcr~ and p.ngine~rS $i,,~e /96S JaJluary 26, 2006 USH .- Central Florida Division 600 N. West shore Hlvd Ste. GOO Tampa, Flurida 33609 Rcferenc~: (;restview Bills 7fi16 Weehawken Drive 7.cphyrhil1s, Florida p(:IIJ)it#4417 Our projt':l't# 0&-0011 PUJl.u<\ut to your reqm:st we perfonncd a lirnitell structural review of the above ;rcterence.d StrUclU1e JanUary 25, 2006. More spedticl111Yl OUI task was to perfonn visual inslleclion of tht': driveway apron. It is uor opinion that the driveway apron will mecl 01' suct:.t".O'is the nece....sluy criteria I*f FlotiUa Duilding Curle.2U(l1. This GOnoludes O1lr investigation a:o; we undersland it: our condwiom ate b...."cd on: time of lhe inspection. If couditions cbanw- from observati"n, noted above or you ,houk! have 30Y fw the! question3 or neeu llny fUrther e}(planatioIlS please do not hesitate to contaCt IL'\. ' ............ ~?t': W~ ~~ ~ ........ ~ ~O..~\C~N$iJ..f(~ l. w.o \. . 0 I : No. . 1 : .. .' . . - . . = . . .. /l!; I .~.. . .: .::~ ",' ,~ft.# .,,-1' SincerelY, Architectural Services and Engineering Keith Sams -7~~/,( 4- ~=~ Kimley"Horn and Associates, Inc, January 27, 2006 . 5344 Ninth Street Zephyrhills, Florida 33542 Mr. Bill Burgess Building Official City of Zephyrhills 5335 8th Street Zephyrhills, Florida 33540 Re: Crestview Hills Lot 90 Dear Mr. Burgess: I have reviewed the As-Built Survey of the lot grading for the subject lot and find it in substantial conformance with the Lot Grading Plan previously approved by the City. If you have any questions, please do not hesitate to contact me at (813) 788-0400. Sincerely, KIMLEY -HORN AND ASSOCIATES, INC. ~rt~ Stuart M. Rogers, P .E. Senior Project Manager SMR:bas Attachments cc: u.s. Home H:\049791001 - Crestview Lot Grades\USHOME Lot Grades\012706 Lot 90 USH.doc . TEL 813 788 0400 FAX 813 782 4978 FINAL BOUNDARY SURVEY LOT 90 CRESTVIEW HILLS PASCO COUNTY, FLORIDA, SEC. 35 , TWF'. 25 S, RNG, 21 E. BEARING BASIS: NORTHERLY LOT LINE OF LOT 90 BEING S 89'36'03" W N o ,.., '.- PREPARED FOR & CERTIFIED TO: NORTH AMERICAN TITLE CO. NORTH AMERICAN TI'ILE INS. CO. CRAIG & ELLEN GESELL ~ ..J <<: (.) Ul. ~y REVIEWED p JIJv - - LOT 91 II 25.00'. '" ...J <( ~ I FIR 5/8" ;8 NO 10 ~~' . ~ ~ ....'~"'. N 89'36'03" E ~ P&M 106.83' 3." : b ** " b: ....J..,~7..:) -1- - - :~- --.-gi;~;}c- - -~r -l I 44.3'~) l' 1:',,1. CONC I WALL * , 20.6' w >1 0::: o i' ~ z~ ~'i' w~ ~ ~ ~ ~ <.> 3: ~ ~ <( :r: w w 3: 6.0' . o a o l!) I ....~5..0'.L 'i- l~46.5') I 3'~~," 25.i)-, I PATIO 1 STORY MASONRY RESIDENCE #7616 LOT 90 b 0; ... .; ,'.,' .<.>~" .. b, b "5 cr I '. to d SJ~. ~ N - . . .r.... O.'.U1 .. ~~..~ ~ .. o' a z I en ( I ....,,,1. 58.4' 1<17.<1' ....3J~~.5;.~:~- - - - - -*-:- - - -~-'-- (146.,)J N . 6.0" 25.00' fl (1<1~ v.,) . FIR 5/8' r"" S 89'36'03" W (P&M) 106.79' LOT 89 .'" .~ 6 '-.PC(P) DESCRIPTION: LOT 90 MAP OR PLAT ENTITLED "CRESTVIEW HILLS", AS RECORDED IN PLAT BOOK 53, PAGES 124 THROUGH 129, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO, 120230 0295 D THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, EASEMENTS AND RESTRICTIONS OF RECORO. UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON ENGINEERING PLANS PROVIDED BY CLIENT. STRUCTURE TIES SHOWN HEREON ARE DERIVED DURING CONSTRUCTION AND MAY VARY UPON COMPLETION. (FORM BOARDS, FOUNDATION, OR STEM WALLS) · = 10' DRAINAGE & UTILITY EASEMENT .. ,= 5' DRAINAGE EASEMENT ... = 10' DRAINAGE EASEMENT 7." FIR 5/8' D.C. JOHNSON o a o l!) S' ..... ~ :: E:, * w Co !" N b a Ul NOT INCLUDED(P) 7." FIR 5/8" D.C. ,JOHNSON PLAT ,BOUNDARY ~RM(P) LOWEST FLOOR ELEVATIONS: LIVING AREA: 147,72' GARAGE AREA: 147,24' ELEVATIONS REFERENCED TO NA TIONAL GEODETIC VERTICA DATUM OF 1929, MEAN SEA LEVEL= 00,00 FT, EFFECTIVE DATE: 9/30/92 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, ~ = CENTERLINE, A/C= AIR CONDITIONER, S/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD. CHB= CHORD BEARING. CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD. FNBD= FOUND NAIL a DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION. MAS.= MASONRY. OR= OFFICIAL RECORD BOOK. PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD a CAP No. 4493, SNaD= SET NAIL a DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL O!~ WAY I ( JOHN R. BEACH Be ASSOCIATES, INC. SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE OLDSMAR, FLORIDA 34677 (813) 854-1276 FAX (813) 855-8370 Drawn By: Square ,'eet: SMS Checked By: Scale: JRB 1"=30' NOT V All 0 WITHOUT THE SIGNA TURE AND Date of Survey: THE ORIGINAL RAISEO SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER Revisions: FORM BOARD TIE-IN 6/24/05 WWW FINAL 1/24/06 DJB 6408.81 :!: US HOME "' <1X ~ ro.o. 2984