HomeMy WebLinkAbout05-4695
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
4695
Permit Number: 4695
Permit Type: ADDITION/ALTERATION
Class of Work: 434-ADD/AL T RESIDENTIAL
Proposed Use: MOBILE HOME SUBDIVISION
Square Feet:
Est. Value:
Improv. Cost: 2,300.00
Date Issued: 7/14/2005
Total Fees: 67.50
Amount Paid: 67.50
Date Paid: 7/14/2005
Work Desc: 7 - NEW WINDOWS
Address: 37642 LANDIS AVE
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: GRAND HORIZONS
Parcel Number:
Name: ROBERT & PEGGY CAIN
Address: 37642 LANDIS AVE
ZEPHYRHILLS, FL. 33542
Phone:
IC H PL
DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB
DUCTS INSULATED LINTEL PRE-METER WATER
SHEATHING FRAME MISC SEWER
MISC INSULATION WALL MISC MISC.
MISC, INSULATION CEILING MISC. MISC.
MISC, DRIVEWAY MISC. MISC,
REINSPEcnON FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Thirty-Five Dollars ($35.00) shall be made for each trip for each trade:
(a) Wrong address (b) Condemned work resulting from faulty construction (c) Repairs or corrections not made when
inspection called (d) Work not ready for inspection when called
(e) Permit not posted on job site (f) Plans not at job site (g) Work not accessible
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances
NO OCCUPANCY BEFORE C.O.
'~ - ~.
CONTRACTOR SIGNA RE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
..
~
Architectural Testing
March 26, 2003
Marsh Fernbaugh, Dire~tor of Testing
Aiside Window Company
3773 State Road
Cuyahoga Falls, Ohio 44309-1365
.KE: Alside 0201 Vinyl Double Hung Wmdow (3' 0" wide by 6' 0" tall) Installed to
Wood Framing
Dear Mr. Fernbaugh.
I have performed an installation fastener analysis for your 0201 double hung window
installed to wood framing, The window size considered was 3' 0" wide by 6' 0" tall. The
design wind pressure for this window, as determined by the testing documented in ATI
Test Report 05-30324.05, is +/- 55.0 PSF.
My analysis assumed using #8 wood screws with a minimum penetration to the wood
framing of 1-1/4". The wood framing must be Spruce-Pine-Fir with a specific gravity of
G=0.42 or better. To safely resist the design wind pressure of the three sizes considered,
6 such screws are required. At installation, use three screws in each jamb: one near the
top corner, one near midspan and one near the bottom comer.
This installation detail is appropriate for smaller windows of this model subjected to the
same design wind pressure. If you have any questions regarding my analysis, please
contact me.
Sincerely,
ARCHITECTURAL TESTING, INC
JAR:jar
cc:
05-30324.05
.<~"~,,,,<_,.,.,,\~,,'."Ii":';, "/," ""
. . . ~ . :, ::-.....
:~'~.,.....: ".' .. '-~" '.
......./.' .....
" . ~
.. .......
, "
". . ,~.
,. ~ (:. .' . .--~.. -
-~ )":, : ..'f;":~
130 Derry Court
York, PA 17402-9405
phone: 717.764.7700
fax: 717.764,4129
www.archtest.com
:,". ~-,,'~,':S':' ~-,~';:;i;,~:>
If' ".. "', ", ',',
~e/~Y
V 3/Z7/d j ,
"'ll
.....ojg
........~
UJln
I ~-t [!~
W~Z
~(J'\P pOlP
f\) ~::!.g
,,0<
Ul'"
n ;S 'i
~ 0 ~
l.. (II
Z 1"1 "-
~ .-
n ~
-I
J> Z
r ]>
J::
(I) ~
.....
t::;t ~
J"'l 0
< t::;t
fT1
.... r
z
t::;t 0
0 f\) w
< C) I
.... W
"-
('l < ~
0 .....
3: Z
-0 t:j
J> 0
Z <
-<
....
z
(I)
-I
J> .
r CD
r I(
J>
-I ~
.....
D '"
Z ~
1"1
I(
r
f',' ..;..~
[P"
~
t::t
:0
;:! ~
~ :z
1:0 Cl
J"'l
:;;0
<
J>
r
r
....
z
(I)
-I
J>
r
r
l>
-I
.....
o
z
....,
J>
(I)
-I
f'Tl
Z
J"'l
:;;0
(/)
I r
J>
-I
CI Cl CI 0-<
UI UI
I I UI -I
W ~ I 10
CI W VI
W W Cl ri-
N N W
~ N :0
~ ~
0 0 10
N N 0 "tl
N 0
,
ri-
:II:
-
:I:::J:
~ CO
~ W ::I a.
~ ~ U)!!.
. Q\ 10
.
X X X !;;~
" Q\ a.s P
" Cl " 0 0"
. . N lIEt;I iQ
.
sag lIE
NO" ;+
10- ::T
10
P
"tl
"tl
,
- 0
"tl
,
"'OJ> j)
,- ri-
+ 100 10
...... + + VII!
I ...... ...... VIP ....
I I CO" P
& ,- no
.jo. UI 1010 ri-I!
0 UI SJI 0
0 "t::t 'P
Cl t;l1O
"tl "tl "tl . VI VI,
III VI "'0- 010
:'> VI v~
:'> :'> ....n
-= VIP
p"tl
5' ....p
I a. 100"
~iQ
I 0
!.~
ri-ri-
::TIO
~Il!
p
::1-1
~i
U)....
ri-P
::Tin
1Ori-
10
1!::1
-10
:::l,
a. III
"tllll
'::T
100
In lIE
~:::l
,-
1O:::l
Inri-
-::T
::110
ri-1Il
::TIO
ri-
ri-~
<
if
I!
In
"
Q\
-I
o
ri-
g.
-0
10
,
I!
:;-
a.
i~
!~
P'lt
"
N
~ . .:,~~"~~,\~k~:\fHiqi}" <
~~~<'?"tj:P \:\ d,,' .h~'t'''~~~'''i!
. '''',.." rL~...;;G.."."'" ^ 'AIJ~~:.,"/...
,~''''?.. .,'f' ' -"~". x'''-'
eo ...~. '"'~'~~'" ~.
.' ~i~t ~",:?~~~~.
~ ..;?,,, ".-,.'. ,..,,~. ~,,-.
....... ~:r ::.: '~' ~~: ';;~;
I'\) -1~' 1'''' ",v''' c:l:? ,,,,t'" -- ~--,
~ -~; , ;:;o~5 ~l }$:J ,f'i:,;,:
o "..r ' " '; y -' ;:g.:t"
f\) ~V..r.'\", " f~..~'A'':
"'. ....~. '''", ~~g,.,:;:::.? ,;:
"" /;1. """,-,,,..:" <"I' ii"
,,,/'-:f.":i-=- ,-,:.~ .,.., ~ "). ,:,">'
JJ~ "..... ...... f1 ":.l" < ~~,~.,.,.
, ~ ;' ~ " 0,( '~- ~ ;,.-;. ~ ~,;;' \ \ .
....
q~~i!i
-<Z-I
~~:%:e
]>:O]>lJ\
r]> ..
...,-1% ..
~Zt::f
...~i
~J::~
001"1
...,:0
-i
....-1(
~~8
!d~t::t
...,~'"
:0 ~
~ ~
Cl
~
r
<
t
J
r
I(
Z
t::t
o
I(
;:l
3:
III
1"1
;0
...,
;0
]>
i!i
z
I:l
'"
c
....
g
'"
:I:
X
!i3
III
....
C
n
ZS
z
I:l
AAMA/NWWDA 10I/1.S.2-97
TEST REPORT SUMMARY
Rendered to:
ALSIDE WINDOW SYSTEMS
SERIES~ODEL: 0201
~E:PVCDoobreHmgWmd~
Results
Title of Test Test Specimen #1 Test Specimen #1- Test Specimen #3 Test Specimen #4
AAMA Ratins: H-LC30 48 x 78 H-LC3S 44 x 77 H..;LC4S* 44 x 60 ' H-LCSS. 36 x 72
- Force 28 lb max. N/A N/A N/A
Air Infiltration 0.16 cfmift2 N/A N/A " N/A
Water Resistance Test Pressure 9.0 Dsf N/A N/A N/A
Uniform Load Deflection Test Pressure 30 Dsf 35 risf 45 Dsf 55 Dsf
Uniform Load Structural Test PressUre :1:45.0 Dsf :1:52.5 Dsf :1:67.5 Dsf :t82.5 'Psf
De~lazin~ Passed N/A N/A N/A
Forced Entry Resistance Passed N/A N/A N/A
Reference should be made to AT! Report No. 05-30324.05 for complete test specimen
description and data.
.
~
Architectural Testing
~A 101/1.S.2-97 TEST REPORT
Rendered to:
ALSlDE WINDOW SYSTEMS
3773 State Road
Akron, Ohio 44309-1365
Report No: 05-30324.05
Test Dates: 01/10/02
And: 01/23/02
Report Date: 02118/03
Expiration Date: 01/23/06
Project Summary: .Architectural Testing, Inc. (AT!) was contracted to perform tests on four
8eriesIModel DH6WW/SLOPE, PVC double hung windows at the Veka, lnc. facility in Fombell,
pennsylvania. The samples tested successfully met the perfomiance requirements for the
following ratings: Test Specimen #1: H-LC30 48 x 78; Test Specimen #2: H-LC35 44 x 77;
Test Specimen #3: H-LC45* 44 x 60, and Test Specimen #4: H-LC55* 36 x 72. Test specimen
descriptions and results are reported herein.
General Note: An asterisk (*) next to the performance grade indicates that the size tested for
optional performance was smaller than the minimum test size for the product type and class.
Test Specification: The test specimen was evaluated in accordance with AAMAINWWDA
101/18.2-97, Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood, Windows and Glass
Doors.
Test Specimen Description:
SerieslModel: 0201
Type: Poly Vinyl Chloride (PVC) Double Hung Window
Test Suecimen #1: H-LC30 48 x 78
Overall Size: 4' 0" wide by 6' 6" high
Top Sash Size: 3' 8-5/8" wide by 3' 1-3/8" high
Bottom Sash Size: 3' 9-5/8" wide by 3' 2-3/8"high
Screen Size: 3' 8-5/16" wide by 3' 2-11/16" high
130 Deny Court
York, PA 17402.9405
pl:1one: 717.764.7700
fax: 717.764.4129
www.archtest.com
05-30324.05
Page 20f8
Test Specimen Description: (Continued)
Test Soecimen #2: H-LC35 44 x 77
Overall Size: 3' 8" wide by 6' 5" high
Top Sash Size: 3'4-5/8" wide by 3' 0-7/8" high
Bottom Sash Size: 3' 5-5/8" wide by 3' 1-7/8" high
Test Soecimen #3: H-LC45* 44 x 60
Overall Size: 3' 8" wide by 5' 0" high
"I
Top Sash Size: 3' 4-5/8" wide by 2' 4-1/4" high
Bottom Sash Size: 3' 5-5/8" wide by 2' 5-5/16" high
Test Soecimen #4: H-LC55* 36 x 72
OverJdl Size: 3' 0" wide by 6' 0" high
Top Sash Size: 2' 8-3/4" wide by 2' 10-3/8" high
Bottom Sash Size: 2' 9-3/4":wide by 2' 11-3/8" high
The following descriptions apply to all specimens. ,
Finish: All vinyl was white.
Glazing Detalls: The sash were exterior glazed with 13/16" thick sealed insulating glass
fabricated from two sheets of 1/8" clear annealed glass and a metal spacer system. The
insulating glass was set onto a double-sided adhesive tape and secured with rigid vinyl
glazing beads.
Frame Construction: The PVC frame was constructed using mitered and welded comer
construction. A rigid PVC adapter was applied to the head.
Sash Construction: The PVC sash were assembled using mitered and welded' comer
construction.
Screen Construction: The screen was constructed from extruded aluminum. The comers
were miter cut and secured with comer keys. Fiberglass mesh screen cloth was
held-in-place with a flexible spline.
Test Specimen Description: (Continued)
Weatherstripping:
Descrintion
0.187" backed by 0.200"
high pile with center fin
0.187" backed by 0.260"
high pile with center fin
0.187" backed by 0.260"
high pile with center fin
\
0.18711 backed by 0.350"
high pile with center fin
0.18711 backed by 0.550" high
vinyl jacket/foam filled bulb
0.18711 backed by 0.300"
diameter, offset vinyl
jacket/foam filled bulb .
l" by 1/2" x 0.250" high .
adhesive backed pile pad
Hardware:
DescriDtion
Metal cam lock
and keeper
Constant force balance system
with locking tilt shoe
Plastic spring-loaded
tilt latch
Die cast sash tilt pin
PVC sash stop
Ouantitv
lRow
1 Row
2 Rows
lRow
lRow
1 Row
4
Quantity
2
4
4
4
4
Location
Lock rail
Head insert, sill, top rail
..
Sash stiles
05-30324.05
Page 3 of8
Exterior meeting rail (exterior)
Exterior meeting rail (interior)
Bottom rail
Meeting rails, one at each end
Location
Lock rail, 8-1/2" from each end
Two per jamb
Top comers of sash
Bottom comers of sash
Jambs, one at each end
Test Specimen Description: (Continued)
Drainage:
Description
Ouanti~
7/811 wide by 3/16"
high weepslot
2
3/4" wide by 3/1611
high weepslot
2
-',
1-1/4" wide by 1/2"
deep weepslot
2
3/8" wide by 1/811
deep weepslot
4
05-30324.05
Page 4 of8
Location
One 2-114" from each .end of the
exterior sill face (with flaps), one at
each end of the center sill wall
Sill screen track, one at each end
..
Sill, one at each end of the interior
jamb track
Bottom sash rail and exterior
meeting rail, one at each end
Reinforcement: The lock rail contained a rectangular shaped, formed steel reinforcement
measuring 0.649" x 0.461" x 0.047" (reference draWing #2707). The exterior meeting rail
and sash stiles contained a "U' shaped steel reinforcement measuring 0.781" x 0.40011
X 0.04711 (reference drawing # 2709).
Installation: The unit was installed in a. wood buck constructed of Spruce-Pine-Fir
construction lumber and sealed at the exterior perimeter with a silicone sealant. A 3/4" x
3/4" wood stop was applied to the interior and . exterior perimeter and secured with 2"
drywall screws spaced approximately 16" on center.
05-30324.05
Page 5 of8
Test Results:
The results are tabulated as follows:
Paralmlllh
Title of Test - Test Method
Results
Allowed
Test SDecimen #1: H-LC30 48 x 78
2.2.1.6.1
2.1.2
Operating Force 28 1bs
Air Infiltration per ASTM E 283
@ 1.57 psf(25 mph) 0.16 cfmltr
35 lbs max.
0.3 cfmltr max.
Note #1: The tested specimen meets the performance levels specified. in AAMAJNWWDA
1 01/L8.2-97 for air infiltration.
,
2.1.3
Water Resistance per ASTM E 547-00
(with and without screen)
WTP = 3.75 psf No leakage
No leakage
2.1.4.2
Uniform Load Structural per ASTM E 330-97 .
(Measurements reported were taken on the exterior meeting rail)
@37.5 psf(positive) 0.03" 0.179" max.
@37.5psf(negative) 0.03" 0.179I1max.
2.2.1.6.2 Deglazing Test per ASTM E 987
Top Sash
In operating direction at 70 lbs
Lift Rail 0.060"/12% 0.500"/100%
Meeting Rail 0.060"/12% 0.500"/100%
In remaining direction at 50 lbs
Left Stile 0.060"/12% 0.500"/100%
Right Stile 0.030"/6% 0.500"/100%
Bottom Sash
In operating direction at 70 lbs
Lift Rail 0.060"/12% 0.500"1100%
Meeting Rail 0.060"/12% 0.500"/100%
In remaining direction at 50 lbs
Left Stile 0.030."/6% 0.500"/100%
Right Stile 0.0.30."/6% 0..500."1100%
05-30324.05
Page 6 of8
Test Results:
Para2raoh
Title of Test - Test Method
Results
Allowed
Test SDecimen #1: H-LC30 48 x 78 (Continued)
2.1.7
Welded Comer Test
Meets as stated
Meets as stated
2.1.8
Forced Entry Resistance per AAMA 1302.5-76
Tests A through G No entry .
No entry
Qptional performance
4.3
Water Resistance per ASTM E 547-00
(with and without screen)
WTP = 9.0 psf No leakage
No leakage
,
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting. rail)
@45.0psf(positive) 0.04" 0.179" max.
@45.0psf(negative) 0.06" 0.179" max.
Test Snecimen #2: H-LC35 44 x 77
optional Performance:
4.4.1 Uniform Load Deflection per ASTM E 330-97
(Measurements reported were taken on, the exterior meeting rail)
@ 35.0 psf(positive) 0.44" See Note #2
@35.0psf(negative) 0.46" See Note #2
. Note #2: The Uniform Load Deflection test is not an .AA.MAJNWWDA 101n.S.2-97
requirement for: this product designation. The data in this report is for information only.
4.4.2 Uniform Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@.52.5 psf(positive) 0.03" 0.163" max.
@ 52.5 psf(negative) 0.03" 0.163" max.
05-30324.05
Page 7 of8
Test Results: (Continued)
Title of Test - Test Method
Results
Allowed
. Paralmlllh
Test SDecimen #3: H-LC45* 44 x 60
Ol;>tional Performance:
4.4.1 Uniform Load Deflection per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 45.0 psf (positive) 0.60" . See Note #2
@45.0psf(negative) 0.53". See Note #2
4.4.2 . Uniform-Load Structural per ASTM E 330-97
(Measurements reported were taken on the exterior meeting rail)
@ 67.5 psf(positive) 0.02" 0.163" max.
@ 67.5 psf(negative) 0.04" 0.163" max.
Test Snecimen #4: H-LC55* 36 x 72
pptional Performance:
4.4.1 . Uniform Load Deflection per ASTM E 330-97
(MeaSurements reported were taken on the exterior meeting rail)
@ 55.0 psf(positive) 0.40" See Note #2
@55.0psf(negative) 0.27" See Note #2
4.4.2 Uniform Load Structural perAS™ E 330-97
(Measure~ents reported were taken on the exterior meeting rail)
@ 82.5 psf(positive) 0.06" 0.131" max.
@ 82.5 psf(negative) 0.02" 0.131" max.
U:>-:';U:';l4.U:>
Page lS of lS
This report is reissued in the name of Alside Window Systems through written authorization of
Veka, lnc. to whom the original report was rendered. The original Veka, Inc. Report No. is
05-30324.01.
Detailed drawings, representative samples of the test specimen, and a copy of this report \\rill be
retained by A TI for a period of four years. The above results were secured by using the
designated test methods and they indicate compliance with the performance requirements of the
above referenced specification. This report does not constitute certification of this product,
which may only be granted by the certification program administrator. This report may not be
reproduce except in full without the approval of .A.Ic:hitectural Testing.
For ARCHITECTURAL TESTING, INC:
tR~~
j/ v7 ()/ ;
1?1./f~ L d
Steven M. Urich, P.E.
Seni,9r P;oject Engineer
2/18 If) :r
Digitally signed by Lynn George
Lynn George
Proj ect Manager
LG:baw
05-30324.05
CITY OF ZEPHYRHILLS PERMIT APPLICATION
BUILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542
813-780-0020 FAX: 813-780-0021
.~
DATE RECE IVED
'7/S /OS
PHONE CONTACT FOR PERMITTING
OWNER'S NAME ih-CrAT' -S tn J?~ ~~ PHONE 51/3 -71l.:z -Db 9 'I
JOB ADDRESS 576r,/;( f~ ~. [/;t"f'.Ly...tL&f//, 53,~/
LEGAL DESCRIPTION: LOT (S) 7 J BLOCK SUBDIVISION.tf~ ;./ ~
PARCEL 10 # (OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPSED: 0 NEW CONSTRUCTION
o ADDITION
DALTERATION
o REPAIR
~ INSTALL
o SIGN
PROPOSED USE:~SGL FAMILY DWELLING
o COMMERCIAL
o MOVE
o DEMOLISH
DMULTI-FAMILY
o INDUSTRIAL
0# OF UNITS
o SWIMMING POOL
o MOBILE HOME
o OTHER
DESCRIPTION OF WORK
D RESTAU~NT & HEALTH D~P~MENT APPROVAL
Jl~w~ ( 7)
BUILDING SIZE
SQUARE FOOTAGE
IbO{)
HEIGHT
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
& (1) SET ENERGY FORMS.
F~rtS .
J;> &'7 ,5Q
/ PERMITS REQUESTED
~ILDING $ bJ..300 VALUATION OF TOTAL CONSTRUCTION
(
0 ELECTRICAL AMP SERVICE 0 Progress Energy 0 W.R.E.C.
0 PLUMBING
o MECHANICAL $ VALUATION OF MECHANCIAL INSTALLATION
o GAS o ROOFING o SPECIALTY 0 OTHER
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAD YES
o NO
BUILDER
SIGNATURE
)<?2~L/ fn,.~
COMPANY
STATE CERT OR REGIST #
******************************************************************
ELECTRICIAN
COMPANY
SIGNATURE
STATE CERT OR REGIST #
******************************************************************
PLUMBER
COMPANY
SIGNATURE
STATE CERT OR REGIST #
******************************************************************
MECHANICAL
COMPANY
SIGNATURE
STATE CERT OR REGIST #
*****************************************************************
OTHER
COMPANY
SIGNATURE
STATE CERT OR REGIST #
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than City regulations. The unde!signed assumes responsibil.ity for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with stat& and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020~
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign po~tions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indica~ion that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR' S/OWNER' S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be aone in compliance with all applicable laws regulating construction, zoning, and land
development.
Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not. limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for 'a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT".
SIGNATURE: OWNER OR AGENT
SIGNATURE: CONTRACTOR
acknowledged
, 2~
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____day of
by
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this _____ day of
by
acknowledged
20
(name of person acknowledged)
Dwho is personally known to me, or
(name of person acknowledged)
C1ho is personally known to me, or
of identification)
take an oath.
Dwho has produced
(type of identification)
and who Ddid [}:lid not take an oath
Signature of person taking acknowledgement
Signature of person taking acknowledgment
Name typed, printed or stamped
Name typed, printed or stamped