Loading...
HomeMy WebLinkAbout06-5355 ., CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 5355 .. Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 5355 MISC 434-ADD/AL T RESIDENTIAL NOT APPLICABLE Address: 5246 16TH ST ZEPHYRHILLS, FL. Township: Range: Book: Lot{s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 11-26-21-0010-17900-0150 2,495.00 1/27/2006 67.50 67.50 1/27/2006 REPLACING 10 WINDOWS - GLASS Name: SHEPPARD,ARVE Address: 5246 16TH ST ZEPHYRHILLS, FL. 33542 Phone: 813 788-8614 / ('~~ \(l ~\~ ~ REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. -~P/ C2 ~~ / PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ... CI~Y OF ZEPHYRHILLS PERMIT APPLICATION ~r~~~ BUI'LDING DEPARTMENT 5335 8TH st, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 . I l' DATE RECEIVED --1Jd3_0ln PHONE CONTACT FOR PERMITTING OWNER'S NAME ,..,.: ( --.'], \) ~~'0 ,-" l { PHONE .'6 \ '.j . ~ -, \; 10 <-. -\;" ~ 3S Y c2. JOB ADDRESS 'SJ. LEGAL DESCRIPTION: LOT(S) BLOCK ,?--- SUBDIVISION PARCEL ID it II-JfD-J\- DOlO -I'l'ioo - C\<bO . (OBTAIN FROM PROPERTY.TAX NOTICE) WORK PROPSED: DNEW CONSTRUCTION DSIGN o ADDITION o ALTERATION [] REPAIR o INSTALL [] MOVE [] DEMOLISH PROPOSED USE: DSGL FAMILY DWELLING o COMMERCIAL DMULTI-FAMILY o INDUSTRIAL Dit OF UNITS o SWIMMING POOL o MOBILE HOMI o OTHER DESCRIPTION OF WORK D RESTAURANT t~ef'rl J 1(& & HEALTH DEPARTMENT APPROVAL /0 u n ~ ) ( Jo II' J -! (llcr'~s- BUILDING SIZE SQUARE FOOTAGE HEIGHT RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. [] BUILDING / C> / I $ ,:./ /:.:.::? --- PERMITS REQUESTED VAL~ATION OF TOTAL CONSTRUCTION o ELECTRICAL AMP SERVICE o Progress Energy [] W.R.E.C. o PLUMBING o MECHANICAL $ VALUATION OF MECHANCIAL INSTALLATION o GAS o ROOFING o SPECIALTY o OTHER TYPE OF CONSTRUCTION: ~. BLOCK o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES [] NO SIGNATURE ,r ~C7/ ~i . Lt~te ~ 1f!(lriY"L -f/ STATE CERT OR REGIST it ***********~***************************************************** BUILDER ELECTRICIAN COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** :::::RE_<Z::; ~/-~4 BI. :::::N:ERT OR REGIST f ****************************************************************** MECHANICAL COMPANY SIGNATURE STATE CERT OR REGIST # ***************************************************************** OTHER COMPANY SIGNATURE STATE CERT OR REGIST # A. NOTI~E OF DEED RESTRICTIONS Tha undersigned understands that this permit may be subject to ~deed restrictions" which may be more restrictive than city regulations. The undersigned assumes respons~bility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and Ibcal regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign po~tions of the ~Cohtractor Sections" of this ~pplication for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indica~ion that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law _ Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone ~A" or "A, etc.", it is understood that a drainage plan addressing a, "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. ~ A permit issued shall.be .construed to be a license to proceed with the work and not as authority to violate,cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for la period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to'the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS 'TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT". '. SIGNATURE: CONTRACTOR SIGNATURE: OWNER OR AGENT acknowledged , 2CL- STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _day of by STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _ day of by acknowledged " 20_ (name of person acknowledged) Owho is personally known to me,or (name of person acknowledged) C1ho is personally known to me, or []who has produced (type and whoO did 0 did not of identification) take an oath. o who has produced (type of identification) and who Ddid [}:iid not take an oath Signature of person taking acknowledgment Signature of person taking acknowledgement Name typed, printed or stamped Name typed, printed or stamped I . ~ Architectural Testing 15 April 2002 Mr. Marsh Fembaugh, Director of Testing Alside, Window Company 3773 State Road Akron, Ohio 44309-1365 RE: Masonry Installation of 0201 Double Hung Window, 3' 0" by 6' 0" Dear Mr. Fembaugh: At your request, I have performed an installation fastener analyses into masonry block walls for Alside double hung windows, Model 0201. The testing of the actual wmdows was done under ATI project 05-30324.02. The fastener analyses provides a 3' 0" wide by 6' 0" high window with an allowable installation design wind pressure (D.P.) of +/- 55.0 psf. To provide this D.P. in a masonry block wall requires 6 Tapcons,each 3/16" in diameter. There should be 3 Tapcons through each window jamb frame, one near the top, one at the midheight, and one near the bottom. The minimum penetration of the Tapcons into solid masonry must be 1-1/4". These results are appropriate for the size window stated in the first paragraph above, and any size smaller, If there are any questions about this analyses, please advise me, Sincerely yours, ARCHITECTURAL TESTING, INe. 130 Derry Court York. PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com ~17( ~ Allen N. Reeves, P .E. Director - Engineering Services~."'!"'" "'., /~ vi", / Z 0 ~ J .......~..~~i~,.i~'Li?, :"..~. o ..... l-'\i,....c.,.':.v _ .,:~'bl~, '~ ,"v i4"<1i. "v QV........I.V"'..6:t..ov "::~~:' C '-i ~'" .\':\I'i6....~... ff# '''(- ~. .~...,. ,')(;:},'" "'-,~J.>"" "" ':.--. ..:'4:'" ~. ~'.'~ _~- ~....flt _~ VQi: ..,:~ ',....., 'CS .:;' 1)..11 J;t, \.1,~~~~, 4.r ~ ...... ~ ~ ~ :~':~ ~ .... jt ..l@ t '.".,,<', ~ ::. ~ <0; 1:,; Hi;, n~ ~h' ~~>~.(j~~. A,"'J.-." _, v,. _~,~ .....,~ "".'I,:i:iJl'~~~..... ..~~ :-~fb"o~Uvu.....~' ~'Cl:-O'; Yl"~~'..~M .' .. ';1.,-' . ~~ail.l'" . " .,~~.., '[J.+~>i ~?Ii\j~;p~~ -... '~~',,-~ ~ ~..("'~~. 8;~_~ - . ANR: am cc: 01-41462 05-30137 .,~~\~;r'" .tj!'~;!;,~t't _. , '<:,. . ..".,l>Q~e.,) .,":A:"""" . _ (',.,..'. .,;c~. . '" . T"~'~~~ '., ,."..J', - '0 "'(~ti;(.. .' ;::;:.~., ~~: :i\< '. . ~... "p.' ~ ,\, . ..,,; ~~.~., .1J;-~~;(~ '/J' :.. ~ ~.:~ ",-.,ic , 'r,; S ,; ~.,..",~'~ ~:~/ ;;,-:) ... /~r; .. , ,,.. .'.::~~~:<. . ~,J~"-{ . ...."~)-\ ,. 1;: t't r,^,:~i}_;.I("' ",'- r : (( I~~,":(~~\.;\ l! P fTi ~ ~ r'1 n -i $ :J: J:1 J> r (/) I-< t::J 1'1 3: o t:l 1'1 r ~ I-< Z t::J 0 o f'\) ~ 0 ....- n o 3: \J J> Z -< r "I r,,~ L r l:;:j $ ~ (/) ~ ~ Cl ;;u -< ~ J> r r ;~ "~ ".I' ~r ...... z (/) -I J> r r J> -I ...... CJ Z ." J> (/) -I fTl Z fTl ;;u (/) =(':)" c::-t'!l _-1~ r:-'<..;;l COt'!l 2'!!J~ ~~C O~~ ~:C~ ff ,~ B\JiLDING SHALL COMPLY W ALL APPLICABLE BUILDING ELECTRICAL, PLUMBING ANn MECHANICAL CODES. .z ~ ;to Q :T<+- ~ III III ;t~ ;'-1 Q,:T ;,11l 10.., <+-p :Till 11l:t OlE :J 3"~ l2.1Il "011I ':T ~~ ~;, ~3" Ill<+- 3"~ g:~ IV<+- ;t~ 2:< 11l;v !.~ <+- :T~ P-I "00 "O<+- , P -8- 2"0 pill <+-' IV. ..,:;- ~g. ct~ ~P , 0'" "'n IIlP p"O ..,p IVlT .z~ . 0 .., [;!"; g~g- ~ q- ~ B\J\LDWG swJ..L COWL '1 wTfl\ ALL ,>J'rLlC,o&U\ crt" Of z$l'~ ol<PwN'lCf. ~ z3:~ ag... :s:~~ >3:l:;:j '" ... i!il~ -<j-f ~~!;j ;:g ~~ g~~ >~ =;! ~> AAMAINWWDA 101/1.S.2-97 TESTREPORTS~Y Rendered to: ALSIDE WINDOW SYSTEMS SERIESIMODEL: 0201 TYPE: PVC Double Hung Window Results Title of Test Test Specimen #1 Test Specimen #2 Test Specimen #3 Test Specimen #4 AAMA Rating H-LC30 48 x 78 H-LC35 44 x 77 H~LC45* 44 x 60 H-LC55* 36 x 72 Operating Force 28 lb max. N/A N/A N/A Air Infiltration 0.16 cfm/ttl N/A N/A N/A Water Resistance Test Pressure 9.0 psf N/A N/A N/A Uniform Load Deflection Test Pressure 30 psf 35 psf 45 psf 55 psf Uniform Load Structural Test Pressure :t45.0 psf :t52.5 psf :t67.5 psf :t82.5 psf Deglazing Passed N/A N/A N/A Forced Entry Resistance Passed N/A N/A N/A Reference should be made to AT! Report No. 05-30324.05 for complete test specunen description and data. .. ~ Architectural Testing AAMAlNWWDA 101/1.S.2-97 TEST REPORT Rendered to: ALSIDE WINDOW SYSTEMS 3773 State Road Akron, Ohio 44309-1365 Report No: 05-30324.05 Test Dates: 01/10/02 And: 01/23/02 Report Date: 02/18/03 Expiration Date: 01/23/06 Project Summary: Architectural Testing, Inc. (AT!) was contracted to perform tests on four SeriesIModel DH6WW/SLOPE, PVC double hung windows at the Veka, me. facility in Fombell, Pennsylvania. The samples tested successfully met the performance requirements for the following ratings: Test Specimen #1: H-LC30 48 x 78; Test Specimen #2: H-LC35 44 x 77; Test Specimen #3: H-LC45* 44 x 60, and Test Specimen #4: H-LC55* 36 x 72. Test specimen descriptions and results are reported herein. General Note: An asterisk (*) next to the performance grade indicates that the size tested for optional performance was smaller than the minimum test size for the product type and class. Test Specification: The test specimen was evaluated in accordance with AAMA!NWWDA IOl/I.S.2-97, Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood. Windows and Glass Doors. Test Specimen Description: SeriesIModel: 0201 Type: Poly Vinyl Chloride (PVC) Double Hung Window Test Specimen #1: H-LC30 48 x 78 Overall Size: 4' 0" wide by 6' 6" high Top Sash Size: 3' 8-5/8" wide by 3' 1-3/8" high Bottom Sash Size: 3' 9-5/8" wide by 3' 2-3/8" high Screen Size: 3' 8-5/16" wide by 3' 2-11/16" high 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com 05-30324.05 Page 2 of8 Test Specimen Description: (Continued) Test Specimen #2: H-LC35 44 x 77 Overall Size: 3' 8" wide by 6' 5" high Top Sash Size: 3' 4-5/8" wide by 3' 0-7/8" high Bottom Sash Size: 3' 5-5/8" wide by 3' 1-7/8" high Test Specimen #3: H-LC45* 44 x 60 Overall Size: 3' 8" wide by 5' 0" high Top Sash Size: 3' 4-5/8" wide by 2' 4-114" high Bottom Sash Size: 3' 5-5/8" wide by 2' 5-5/16" high Test Specimen #4: H-LC55* 36 x 72 Overall Size: 3' 0" wide by 6' 0" high Top Sash Size: 2' 8-3/4" wide by 2' 10-3/8" high Bottom Sash Size: 2' 9-3/4"wide by 2' 11-3/8" high The following descriptions apply to all specimens. Finish: All vinyl was white. Glazing Details: The sash were exterior glazed with 13/16" thick sealed insulating glass fabricated from two sheets of 1/8" clear annealed glass and a metal spacer system. The msulating glass was set onto a double-sided adhesive tape and secured with rigid vinyl glazing beads. Frame Construction: The PVC frame was constructed using mitered and welded comer construction. A rigid PVC adapter was applied to the head. Sash Construction: The PVC sash were assembled using mitered and welded comer construction. Screen Construction: The screen was constructed from extruded alwninwn. The comers were miter cut and secured with comer keys. Fiberglass mesh screen cloth was held-in-place with a flexible spline. Test Specimen Description: (Continued) Weatherstripping: Description 0.187" backed by 0.200" high pile with center fin 0.187" backed by 0.260" high pile with center fin 0,187" backed by 0.260" high pile with center fin 0.187" backed by 0.350" high pile with center fin 0.187" backed by 0.550" high vinyl j acketlfoam filled bulb 0.187" backed by 0.300" diameter, offset vinyl jacket/foam filled bulb 1" by 1/2" x 0.250" high adhesi ve backed pile pad Hardware: Description Metal earn lock and keeper Constant force balance system with locking tilt shoe Plastic spring-loaded tilt latch Die cast sash tilt pin PVC sash stop Quantity I Row 1 Row 2 Rows 1 Row 1 Row 1 Row 4 Quantity 2 4 4 4 4 05-30324.05 Page 3 of8 Location Lock rail Head insert, sill, top rail Sash stiles Exterior meeting rail (exterior) Exterior meeting rail (interior) Bottom rail Meeting rails, one at each end Location Lock rail, 8-1/2" from each end Two per jamb Top comers of sash Bottom comers of sash Jambs, one at each end 05-30324.05 Page 4 of 8 Test Specimen Description: (Continued) Drainage: Description Quantity Location 7/8" wide by 3/16" high weepslot 2 One 2-1/4" from each end of the exterior sill face (with flaps), one at each end of the center sill wall 3/4" wide by 3/16" high weepslot 2 Sill screen track, one at each end 1-1/4" wide by 1/2" deep weepslot 2 Sill, one at each end of the interior jamb track 3/8" wide by 1/8" deep weepslot 4 Bottom sash rail and exterior meeting rail, one at each end Reinforcement: The lock rail contained a rectangular shaped, formed steel reinforcement measuring 0.649" x 0.461" x 0.047" (reference drawing #2707). The exterior meeting rail and sash stiles contained a "U" shaped steel reinforcement measuring 0.781" x 0.400" x 0.047" (reference drawing # 2709). Installation: The unit was installed in a wood buck constructed of Spruce-Pine-Fir construction lumber and sealed at the exterior perimeter with a silicone sealant. A 3/4" x 3/4" wood stop was applied to the interior and exterior perimeter and secured with 2" drywall screws spaced approximately 16" on center. 05-30324.05 Page 5 of8 Test Results: The results are tabulated as follows: Title of Test - Test Method Results Allowed Paragraph Test Specimen #1: H-LC30 48 x 78 2.2.1.6.1 Operating Force 28 Ibs Air Infiltration per ASTM E 283 @ 1.57 psf(25 mph) 0.16 cfrnlfl? 35 Ibs max. 2,1.2 0.3 cfrnlft2 max. Note #1: The tested specimen meets the performance levels specified in AAMAlNWWDA 101/1.8.2-97 for air infiltration. 2,1.3 Water Resistance per ASTM E 547-00 (with and without screen) WTP = 3.75 psf No leakage No leakage' 2.1.4.2 Uniform Load Structural per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 37.5 psf (positive) 0.03" 0.179" max, @ 37.5 psf(negative) 0.03" 0.179" max. 2.2.1.6.2 Deglazing Test per ASTM E 987 Top Sash In operating direction at 70 lbs Lift Rail 0.060"/12% 0.500"/1 00% Meeting Rail 0.060"/12% 0.500"/100% In remaining direction at 50 Ibs Left Stile 0.060"/12% 0.500"/1 00% Right Stile 0.030"/6% 0.500"/100% Bottom Sash In operating direction at 70 lbs Lift Rail 0.060"/12% 0.500"/100% Meeting Rail 0.060"/12% 0.500"/100% In remaining direction at 50 lbs Left Stile 0.030"/6% 0.500"/100% Right Stile 0,030"/6% 0.500"/100% 05-30324.05 Page6of8 Test Results: Paragraph Title of Test - Test Method Results Allowed Test Specimen #1: H-LC30 48 x 78 (Continued) 2.1.7 Welded Comer Test Meets as stated Meets as stated 2.1.8 Forced Entry Resistance per AAMA 1302.5-76 Tests A through G No entry No entry Optional Performance 4.3 Water Resistance per ASTM E 547-00 (with and without screen) WTP = 9.0 psf No leakage No leakage 4.4.2 Uniform Load Structural per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 45.0 psf (positive) 0.04" 0.179" max. @45.0psf(negative) 0.06" 0.179"max. Test Specimen #2: H-LC35 44 x 77 Optional Performance: 4.4.1 Uniform Load Deflection per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 35.0 psf (positive) 0.44" See Note #2 @ 35.0 psf(negative) 0.46" See Note #2 Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 requirement for this product designation. The data in this report is for information only. 4.4.2 Uniform Load Structural per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 52.5 psf(positive) 0.03" 0.163" max. @ 52.5 psf(negative) 0.03" 0.163" max. 05-30324.05 Page 7 of8 Test Results: (Continued) Paragraph Title of Test - Test Method Results Allowed Test Specimen #3: H-LC45* 44 x 60 Optional Performance: 4.4.1 Uniform Load Deflection per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 45.0 psf(positive) 0.60" See Note #2 @ 45.0 psf(negative) 0.53" See Note #2 4.4.2 Uniform Load Structural per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 67.5 psf(positive) 0.02" 0.163" max. @ 67.5 psf(negative) 0.04" 0.163" max. Test Specimen #4: H-LC55* 36 x 72 Optional Performance: 4.4.1 Uniform Load Deflection per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 55.0 psf (positive) 0.40" See Note #2 @ 55.0 psf(negative) 0.27" See Note #2 4.4.2 Uniform Load Structural per ASTM E 330-97 (Measurements reported were taken on the exterior meeting rail) @ 82.5 psf(positive) 0.06" 0.131" max. @ 82.5 psf(negative) 0.02" 0.131" max. 05-30324.05 Page 80f8 This report is reissued in the name of Alside Window Systems through written authorization of Veka, mc. to whom the original report was rendered. The original Veka, mc. Report No. is 05-30324.01. Detailed drawings, representative samples of the test specimen, and a copy of this report will be retained by A TI for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the perfonnance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator. This report may not be reproduce except in full without the approval of Architectural Testing. For ARCHITECTURAL TESTING, INC: i?~~ ))22/ Steven M. Urich, P.E. SenY>r Ifoject Engineer Z!18/() '3 Digitally signed by Lynn George Lynn George Proj ect Manager LG:baw 05-30324.05 04/15/2004 10:b5 ~,:lI::J'::l:':::'::~:':::'::l::J I ~ AL~!V~ ~~iN~~lNb t-'A\:ot:. l:ll;:j Archttectural T.,ttn. March 22, 2004 Marsh Fembaugh, Director of Testing AIside: Window Company 3713 State Road Cuyahoga Falls, Ohio 44309-1365 RE: Masonry InItallation afOSO! Double Huna Windows. Dear Mr. Fembaugh: I have performed an installation fastener analysis for your 0501 Double Hung Windows installed to masonry walls. The windows CODSUtered were 1UI follows: Size 4' 4" x 7' 0" )'8" x6' S" 3' 8" X 6' 0" 3' 0" x 6' 0" 3' 0" x Sf 0" 4' 411 X 5' I" 4' 4" X 5' }" DP 2S psf 40 psf 45 psf 4S psf 60 psf 35 psf 4S psf Teat R~rt No. An OS-30388.01 An 05-30388.01 An OS-30388.01 AT! 05-30388.01 An 05-30388.01 An 05-30419.01 An 05-30419.01 My analysis assumed using 3/16" diameter Tapcon anchors With a minimum embedment of 1.114". To safely resist the design wind preasures above~ 8 such anchors are required to fasten the window to the masonry frame. At installation, use three anchors in each jamb 6't frOtn each corner and one at the mid-height, and two in the head 6" from each corner. If you have any questions regarding my analysist please contact me. Sincerely, ARCHITECTIJRAL TESTING, INC JAR:jar cc: 01.50106.01 130 Derry Court York. PA 1740~-9405 phon~; 717.7154.7700 t.x; 717.764.41251 www..rchtest.com "~' i ;'~~~2::~:\;~:" . ..!" .......,.\P..C..>. ';" .... . ,,-,,~ .~ . >to.~ ..~ .,~..,., ('" . .:'..., ........ ~.r..I!. ". . ,. ..".. ...~jlIi...t.;.o/i'~...~ . , "'.:", . ..~ .,. , ~: \:. ':~)-:::i~'~~~"~'..." . ,.~. ...... ~ C l~tl'",' _.. , :z:~ 1/' / 7~2~1 ~4/15/2004 10:55 3309222220 fi.~1 I 9-4 ~~J ~ ."::~"II~ '" .. ... 1"'''.4, ... to, ." I ;~ J"/-:""~:.-\ 4' ~"':',~ t """t. ....:~ .. ';'/"~:'~' I ,;..\"t'. ~ "~.:I::l.': (J).. ~,'t~~..:~. ; ';' ~',~.<' ,~: .. -. .t.... ~ .. z 8 f") 9 8 c: m r- /'TI ALSIDE E~~INEERING SECTlON - AA Cl'J ; C') 11 z i )> PI-'\GE rH .. I . ~ :. .;.:.~',~~ . ".~,,'. "", i f,':j..:..l~ :.,.~:'..~.,~..J. 'I' ..(':. ..~\ ,~.~ f: . :\..': ." ': .~ #I~',,: I~::' . . ~ ~.':. t:'::; .-..{ \ .~":, il'~ ~I!I. ~"i !~: CD ~ .. . f,> ~~~~~,~~ ! ~!Iilii! ~; Ii ~la~JiS I I g99gggg-l ... I i~ 1''1w I I: ~~&:&1tt~j i (ihj~ ,.. I-! ~!;:d , X)(XXX)(X !Z~g~!~:~ i I' I~;IJ z ~ 1+H-t+H-I+H-....~ I i lIiUI ~ ~/lI!1l~~$iill i o Q Q Q coo a 1iI~ IIi 111111! , p ~ ." ',~ ; I ".~ I ~.' , \J 'j' ~. :::f ~ ~~gt J~J~ ~~!Jl , ' CD -< AAMAlNWWDA 10I/1.S.2-97 TEST REPORT Rendered to: ALSIDE WINDOW COMPANY . SERIESIMODEL: 0501 TYPE: PVC Double Hung Windows Summary of Results Title of Test Test Test Test Test Test Specimen #1 Specimen #2 Specimen #3 Specimen #4 Specimen #5 AAMA Rating H-LC25 52 x 84 H-LC40 44 x 77 H-LC45* H-LC45* H-LC60'" 44 x 60 36 x 72 36 x 60 Uniform Load Deflection Test Pressure :1:25 psf :1:40 osf +45/-50 psf :1:45 psf +60/-65 psf Operating Force 33 lb max. N/A N/A N/A N/A Air Infiltration 0.09 cfm/tt2 N/A N/A N/A N/A Water Resistance Test Pressure 9.0 psf N/A N/A N/A N/A Uniform Load Structural Test Pressure :87.5 psf :1:60.0 psf +67.5/-75 psf :1:67.5 psf +90/-97.5 psf Deglazing Passed N/A N/A N/A N/A Forced Entry Resistance Grade 10 N/A N/A N/A N/A Reference should be made to ATI Report No. 05-30388.01 for complete test specimen description and data I . ~ Architectural Testing AAMAfNWWDA 10I/1.S.2-97 TEST REPORT Rendered to: ALSIDE WINDOW COMPANY 3773 State Road Cuyahoga Falls, Ohio 44223 Report No: 05-30388.01 Test Dates: 06/19/02 ~d: 06/20/02 Report Date: 07/08/02 Expiration Date: 06/20/06 Project Summary: Architectural Testing, Inc. (AT!) was contracted by Alside Window Company to perform tests on five SerieslModel 0501, PVC double hung windows at their facility located in Cuyahoga Falls, Ohio. The samples tested successfully met the performance requirements for the following ratings: Test Specimen #1: H-LC25 52 x 84; Test Specimen #2: H-LC40 44 x 77; Test Specimen #3: H-LC45* 44 x 60; Test Specimen #4: H-LC45* 36 x 72; Test Specimen #5: H-LC40 36"x 60. Test specimen descriptions and results are reported herein. General Note: An asterisk (*) next to the performance grade indicates that the size tested for optional performance was smaller than the minimum test size for the product type and class. Test Specification: The test specimens were evaluated in accordance with AAMNNWWDA 10111.S.2-97, Voluntary Specificationsfor Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. Test Specimen Description: SerieslModel: 0501 Type: Poly Vinyl CWoride (PVC) Double Hung Window Test Soecimen #1: H-LC25 52 x 84 Overall Size: 4' 4" wide by 7" 0" high Top Sash Size: 3' 11-13/16" wide by 3' 3-5/8" high Bottom Sash Size: 4' 0-13/16" wide by 3' 4-5/8" high Screen Size: 3' 11-7/16" wide by 3' 4-112" high 130 Derry Court I. York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 .[ 05-30388.01 Page 2 of8 Test Specimen Description: (Continued) Test Specimen #2: H-LC40 44 x 77 Overall Size: 3' 8" wide by 6" 5" high Top Sash Size: 3' 3-13/16" wide by 3' 0-1/8" high Bottom Sash Size: 3' 4-13/16" wide by 3' 1-1/8" high Test Specimen #3: H-LC45* 44 x 60 Overall Size: 3' 8" wide by 6" 5" high Top Sash Size: 3' 3-3/4" wide by 2' 3-5/8" high Bottom Sash Size: 3' 4-3/4" wide by 2' 4-5/8" high Test Specimen #4: H-LC45* 36 x 72 Overall Size: 3' 0" wide by 6" 0" high Top Sash Size: 2' 7-13/16" wide by 2' 9-5/8" high Bottom Sash Size: 2' 8-3/4" wide by 2' 10-5/8" high Test Specimen #5: H-LC60* 36 x 60 Overall Size: 3' 0" wide by 5" 0" high Top Sash Size: 2' 7-3/4" wide by 2' 3-5/8" high Bottom Sash Size: 2' 8-3/4" wide by 2' 4-5/8" high The following descriptions apply to all specimens. Finish: All vinyl;was white. Glazing Details: The sash were interior glazed with 13/16" thick, sealed insulating glass fabricated from two sheets of 1/8" clear, annealed glass and a steel spacer system. The glass was set onto a double-sided adhesive tape and secured with rigid vinyl glazing beads. Frame Construction: The PVC frame was constructed using mitered and welded comer construction. Rigid PVC snap-in adapters were located at head and sill. 05-30388.01 Page 3 of8 Test Specimen Description: (Continued) Sash Construction: The PVC sash were assembled utilizing mitered and welded comer construction. Screen Construction: The screen was constructed from extruded aluminum. The comers were miter cut and secured with corner keys. Fiberglass mesh screen cloth was held-in-place with a flexible spline. Hardware: Description Quantity Location Metal carn lock and keeper 2 Interior meeting rail, one 8-1/2" in from each end, mating keepers at the exterior meeting rail Plastic tilt latch 4 Interior meeting rail, and top rail one at each end Constant force balance system with locking pivot shoes 4 Interior and exterior j arnb tracks Metal pivot bar 4 Bottom rail and exterior meeting rail, one at each end Drainage: Description Ouantity Location I" wide by 5/16" high weeps lot 2 One 5-1/4" from each end of the exterior sill face draining the hollow I" wide by 1/4" high weepslot with foam baffles 4 Intermediate sill leg draining the interior track, and exterior sill track one at each end 1-114" wide by'1I2" high weephole 2 Sill adapter at interior jamb track, one at each end 3/8" wide by 3/16" deep weepslot 4 Bottom sash rail, and exterior meeting rail, one at each end 05-30388.01 Page 4 of 8 Test Specimen Description: (Continued) Weatherstripping: Description Quantity Location 0.187" backed by 0.240" high pile with center fin 1 Row Head and sill adapters, bottom rail 0.187" 'backed by 0.240" high pile with center fin 2 Rows Bottom sash stiles, 0.187" backed by 0.240" high pile with center fin 3 Rows Top sash top rail and stiles 0.187" backed by 0.350" high pile with center fm 1 Row Bottom sash stiles, top sash meeting rail (exterior) 0.187" backed by 0.150" high pile with center fm 1 Row Bottom s~h meeting rail, and top sash meeting rail 0.187" backed by 0.375" diameter, offset, vinyl j acket/hollow/foam- filled bulb 1 Row Bottom sash bottom rail Contour fit adhesive backed closed cell foam pads 2 Sill adapter at exterior jamb tracks Reinforcement: The exterior meeting rail and top sash stiles contained a fonned steel reinforcement measuring 0.635" x 0.265" x 0.050" (reference drawing # UY007812). The interior meeting rail contained a formed steel reinforcement measuring 0.715" x 0.680" x 0.050" (reference drawing # UY008812). The bottom sash stiles contained a formed steel reinforcement measuring 0.450" x 0.655" x 0.050" (reference drawing #UY007812). Installation: The unit was installed in a wood buck constructed from Spruce-Pine-Fir construction lumber and sealed at the interior and exterior perimeter with a silicone caulking, with the' exception of an approximate 6" long void at each interior sill comer. The unit was secured to the buck using four #8 x 2-112" long screws, one at the top and bottom of each jamb. 05-30388.01 Page 5 of8 Test Results: The results are tabulated as follows: Paragraph Title of Test - Test Method Results Allowed Test Specimen #1: H-LC25 52 x 84 2.2.1.6.1 Operating Force 331bs 35 lbs max 2.1.2 Air Infiltration (ASTM E 283-91) @ 1.57 psf (25 mph) 0.09 cfin/ft2 0.3 cfin/ft2 max. Note #1: The tested specimen meets (or exceeds) the performance levels specified in AAMAINWWDA 101/18. 2-97 for air infiltration. 2.1.3 Water Resistance (ASTM E 547-00) WTP = 3.75psf No leakage No leakage 2.1.4.2 Uniform Load Structural (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @37.5psf(positive) 0.05" 0.191"max. @37.5 psf(negative) 0.04" 0.191" max. 2.2.1.6.2 Deglazing Test (ASTM E 987-98) Top Sash In operating direction at 70 Ibs Top Rail 0.100"/20% 0.500"/100% Meeting Rail 0.100"/20% 0.500"/100% In remaining direction at 50 Ibs Left Stile 0.060"/12% 0.500"/100% Right Stile 0.060"/12% 0.500"/100% Bottom Sash In operating direction at 70 Ibs Bottom Rail 0.125"/25% 0.500"/1 00% Meeting Rail 0.100"/20% 0.500"/100% In remaining direction at 50 Ibs Left Stile 0.060"/12% 0.500"/100% Right Stile 0.060"/12% 0.500"/100% 05-30388.01 Page 6 of8 Test Results: (Continued) Paragraph Title of Test - Test Method Results Allowed Test Specimen #1: H-LC25 52 x 84 (Continued) 2.1.7 2.1.8 Welded Comer Test Passed <100% of Weld Line Forced Entry Resistance (ASTM F 588-97) Type: A Grade: 10 Lock Manipulation Test Tests Al through A7 Lock Manipulation Test Optional Performance No entry No entry No entry No entry No entry No entry 4.3 Water Resistance (ASTM E 547-00) (with and without screen) WTP = 9.0 psf No leakage No leakage 4.4.1 Uniform Load Deflection (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 25.0 psf (positive) 0.52" See Note #2 @ 25.0 psf(negative 0.53" See Note #2 Note #2: The Uniform Load Deflection test is not an AAMA/NWWDA 101/18.2-97 requirement for this product designation. The data is recorded in this report for information only. Test Specimen #2: H-LC40 44 x 77 Optional Performance 4.4.1 Uniform Load Deflection (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 40.0 psf(positive) 0.51" See Note #2 @ 40.0 psf (negative 0.44" See Note #2 Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 requirement for this product designation. The data is recorded in this report for infonnation only. , 4.4.2 Uniform Load Structural (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 60.0 psf (positive) 0.08" 0.159" max. @ 60.0 psf(negative) 0.05" 0.159" max. 05-30388.01 Page 7 of8 . Test Results: (Continued) Paragraph Title of Test - Test Method Results Allowed Test Specimen #3: H-LC45* 44 x 60 Optional Performance Uniform Load Deflection (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 45.0 psf (positive) 0.57" See Note #2 @ 50.0 psf (negative) 0.57".. See Note #2 Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 requirement for this product designation. The data is recorded in this report for information only. 4.4.1 4.4.2 Uniform Load Structural (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 67.5 psf(positive) 0.04" 0.159" max. @ 75.0 psf(negative) 0.04" 0.159" max. Test Specimen #4: H-LC45* 36 x 72 Optional Performance 4.4.1 Uniform Load Deflection (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 45.0 psf (positive) 0.35" See Note #2 @ 45.0 psf(negative) 0.22" See Note #2 Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 requirement for this product designation. The data is recorded in this report for information only. 4.4.2 Uniform Load Structural (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 67.5 psf(positive) 0.03" 0.127" max. @ 67.5 psf(negative) 0.02" 0.127" max. 05-30388.01 Page 8 of8 Test Results: (Continued) Paragraph Title of Test - Test Method Results Allowed Test Specimen #5: H-LC60* 36 x 60 Optional Performance Uniform Load Deflection (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 60.0 psf(positive) 0.37" See Note #2 @ 65.0 psf(negative) 0.32" See Note #2 Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 requirement for this product designation. The data is recorded in this report for information only. 4.4.1 4.4.2 Uniform Load Structural (ASTM E 330-97) (Measurements reported were taken on the exterior meeting rail) @ 90.0 psf(positive) 0.04" 0.127" max. @ 97.5 psf(negative) 0.03" 0.127" max. Detailed drawings, representative samples of the test specimen, and a copy of this report will be retained by A TI for a period. of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator. This report may not be reproduced except in full without the approval of Architectural Testing. For ARCHITECTURAL TESTING, INC: tR~~ Digitally signed by Lynn George Lynn George Proj ect Manager LG:nlb 05-30388.01 ~. DISCLOSURE STATEMENT FOR OWNER CI.TY OF ZEPHYRHILLS BUILDING DEPARTMENT I, A'{"\Je . Shear0....d . have read and fully understand and agree to the provisibns of th1s 1nstrument. The undersigned states and affirms that he or she is desirous of constructing, renovating, adding to or reroofing his or her own domicile" that he or she actually occupies, or will occupy by said domicile, and same is not for rent, lease or sale. That he or she shall comply with the following conditions: L That the owner and he or she alone shall act as the builder for all phases of construction. That the owner will comply with all provisions of the City of Zephyrhills ordinances and codes pertinent to -the building. That in the event various phases of construction are subcontracted, he will engage only properly licensed subcontractors and will personally supervise such work.. That in the event the Building Inspector shall require corrections to be made, the owner will assume full responsibility to insure they are made, and upon completion will call for a reinspection before proceeding with the building. That the owner shall assume full responsibility for the construction and will not expect supervision of his work from the City of Zephyrhills Building Department. That prior to final inspection any additional fees, including reinspection fees, must be paid in full. A written request from this office shall constitute an official notice_to pay additional fees. That the owner shall comply with all City, State and Federal laws in regard to social security, workman's compensation, lien laws, etc., where applicable. That the owner shall comply with all the safety codes issued by the Florida Industrial Commission. Sta~ la~re~res.~ons~~ction to ~e done by licensed contractors. You have r~1ed for a perm1 un er an exemption to that law. The ex-;mption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct onsite supervision of the construction yourself. You may build or impr~ea one-family or two-family residence or a far.m outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building pr residence must be for your own use or occupancy. It may not be built or substantially improved for sale or lease. If you sell ;or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved if for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. =~~ S'GNA:nuy /;:t~ ~~~ . l?HONB y~'~? t ~_. _.:.. __I ~ _ . 2. 3. 4. s. 6. 7. 8. 9. DATE / _..- :J-(- bC WITNESS l?ERM:IT #: