HomeMy WebLinkAbout06-5504 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT t () !. l ("1/)\.,..., I), 5504 Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 5504 COMMERCIAL FIRE ALARM SYSTEM NOT APPLICABLE Address: 6936 MEDICAL VIEW LN ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHllLS Parcel Number: 02-26-21-0290-00000-0070 9,847.31 3/02/2006 290.00 290.00 3/02/2006 FIRE ALARM SYSTEM INSTALLATION Name: NORTH WIND PROPERTY MANAGEMEN Address: 6936 MEDICAL VIEW IN ZEPHYRHILLS, FL. 33542 Phone: FIRE PERMIT FEES 210.00 /, ~~~~ x0 ~\~~~\~ REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. ~t~GNATURE ~M~ CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS PERMIT APPLICATION BUILDING DEPARTMENT 5335 8m St, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECEIVED 3'" / - Db PHONE CONTACT FOR PERMITTING "7 J;l '7 - 7 ~;2 - /9'7 :3 JJd- PHONE g 13 $I 3.1 9.3 0 i rL. 33~ i/::J. OWNER'S NAME n. ll"lI^ /.i~YJ1\ + iAPUr\yL JOB ADDRESS 6 '13 7 'df edtc El L ~ e VI/' L lit: e LEGAL DESCRIPTION: LOT(S) BLOCK PARCEL 10 # Q2.126121/()~tlOIDooot::YOQ6() , " I WORK PROPSED: _NEW CONSTRUCTION 0 ADDITION DALTERATION 2. e"pJ, V rA I 'l k I SUBDIVISION (ORTAIN FROM PROPF.RTY TAX NOTTeF.) o REPAIR o INSTALL DSIGN PROPOSED USE: DSGL FAMILY DWELLING o COMMERCIAL o MOVE o DEMOLISH DMULTI - FAMIL Y o INDUSTRIAL 0# OF UNITS o SWIMMING POOL o MOBILE HOME o OTHER c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK 7/elu f', r(" /X/~ r:4!J ~ V Sf" i-1'J f/i S 1JrJ (/lIth II / SQUARE FOOTAGE ~ 5 00 HEIGHT BUILDING SIZE RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. & (1) SET ENERGY FORMS. n FORMS. ,... _ ~ C;I-- ~~l~ c- <::-;r-- '" PERMITS REQUESTED J~./ Cj.) c- ~ VALUATION OF TOTAL CONSTRq,CTION . /111 ~ ~~.e 15/'/ ,< ( ~;;:;; '~/..I o Progress Ene~~ 0 W.R.E.C. o BUILDING o ELECTRICAL o PLUMBING o MECHANICAL $ '1.81./ 7 II 31 , AMP SERVICE $ VALUATION OF MECHANCIAL INSTALLATION o GAS o ROOFING o SPECIALTY o OTHER TYPE OF CONSTRUCTION: 0 BLOCK o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAO YES 0 NO BUILDER COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** SIGNATURE COMPANY ~-rD~ SoL-vi/un 11JC.. STATE CERT OR REGIST # ~ FOO(}() ~'11 ********************************************************** PLUMBER COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** MECHANICAL COMPANY SIGNATURE STATE CERT OR REGIST # ***************************************************************** OTHER COMPANY SIGNATURE STATE CERT OR REGIST # "~I'.L'y 'V'I ,~v;t"1 '1.1.1 ,I II,II~ Building :Oepartment ,'5335 ~8th,Street .zephyrhllls, :Florida 33542' 81'3':780':0020 ~Fax:Cover'Sheet TO: Guy I Total Solutions .Fax: 727 -943-59~ 9 FROM: DATE: SUBJ: Ef>S 10/"(O.d Sean 3/2106 Fire'Marshall Inspection sheet ''''';:;;j~Hmim::::: i: ;~; ~ :~: XO :U.ON/:[dX.I. 616SEt6LZL18 lU^I:[;):[l{ W~ 1z:ao nH~/900Z/Z0/H~W ~HOd~H NOI~~VSNVH~ ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813) 780-0041 Fax (813) 780-0044 Fire Chief Robert Hartwig FIRE SERVICE USER FEES A ~ . c' _ \, ~ Owner: I ~\ , ~ I~CJ"'- )~c Billing Address: ~ ~3 l ~'-,<..~ .' 1~~h5f'~( ) \="\ 3L(~ 7-;;'7 -7'1;,2.- /993 Occupancy No.: Plan No.: 0 ~ - Business Name: Business Address: Business Phone No,: Business Fax No.: Contact: CJO 2/ V-2 ' 731 /PJct~ 1/r1'W~ Billing Phone No.: Billing Fax No,: Contact: SPRINKLER SYSTEMS D Automatic $15 FALSE ALARM FEE 1st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $25 5th Alarm $50 6th Alarm $75 7th Alarm $100 8th Alarm $150 9th Alarm $200 10th Alarm $250 Non Compliance $150 "Affidavit of Service/Repair" PLAN REVIEW FEES INSPECTION FEES PERMIT FEE ~ Site PI," N/C Annual N/C I Building Plans ,04 sf 1 st Re-inspection $25 RevIsion .06 sf 2nd Re-inspection $50 3rd Re-inspection $125 STANDPIPE SYSTEM 4th Re-inspection $250 [I Per Riser $25 5th Re-Inspection $500 Construction $15 Commercial $25 GREASENENTILATION D Hood/Ducts $15 Kitchen Suppression $15 PLANS TOTAL 12b ~ INSPECTION TOTA~ PERMIT TOTAL! ;;J./ {) r~ FALSE AT~::L I comm,"~~.e.t ..;, ~ f"~ ~ l.dAN't'~~AL &-.<.-l ;;; ~1 0 oI1-e r C-4-'~S uJ l 0 OL f-e.("~..~ I . SPRINKLER SYSTEMS SPRINKLER SYSTEMS ~ 0 - 25 Heads ~ Hydro Undergrounds $45 26 plus Heads Hydrostatic System $45 Wet Acceptance $30 Dry Acceptance $45 Hydrant Flow $25 Hood / Booth $30 FIRE PUMP Grease Duct $15 [] Per Pump $100 FIRE ALARM SYSTEM FIRE ALARM SYSTEM El 0 - 25 Devices $30 ~ System Acceptance ~ 26 plus Devices $60 Recall Acceptance $50 SUPPRESSION SYSTEMS OTHER t Wet $35 Fire Wall/Smoke Wall $15 Dry $35 LP Gas $25 CO2 $35 Natural Gas $25 Other $35 Fuel Tanks $25 Tent $15 GREASENENTILATION [] Hood/Ducts $35 FIRE PUMP D Fire Pump $15 FIRE ALARM SYSTEM 1Cl Detection ($15\ '1> tJ -.II" \ e. -fc..c... 'I. 7 dl^- 't5 F ~ ~o y, OTHER t LP Gas Natural Gas Fire Works Fuel Tanks $45 $45 $25 $45 Date: "3Jlf O~ ~r'y &rv::-II - ffl Inspector: 'a ii m A TOTAL SOLUTION FIRE PROTECTION GROUP BOSCH STATE FIRE SPRINKLER LICENSE #92353800012002 STATE FIRE ALARM LICENSE #EFOOO0441 www.atotalsolution.com Certified Security Dealer Power of Attorney August 30, 2005 To Whom It May Concern: This will serve as a power of attorney for John S. Robinson, Guy T. Baker or Nathan Going to act on my behalf for signing any documents pertaining to work on fire alarm systems involving the following company: A Total Solution, Inc. Security and Fire Protection 3531 Keystone Road Tarpon Springs, FL 34688 License #EF0001139 The people named above are authorized to pick up papers, drawings, permits, etc. pertaining to this activity and this letter supercecJes all previous correspondence. Please remove all other names from your records. Sincerely, ~\~& Charles F. Ragghianti Branch Manager On this .30 day of~, 2005, before me personally appeared d..ha.rle..s r. ~hian+" to me known to be the same person and described in and who executed the foregoing instruments and acknowledged that he executed the same. ","'" ~ JudiIh E JalMn . ~ . My Commission 00269878 '\;010,..;1 Expires December 07 2007 ~;T' E ~...DJ. *" g~S- otary Pub'ic Sig ture and Date Stamp 3531 Keystone Road, Tarpon Springs, Florida 34688-7815 Local (727) 942-1993 Central Florida 1-888-ATS-FIRE Fax (727) 943-5919 Parcel Information for: 02-26-21-0290-00000-0060 Card: 001 Page 1 of 1 Search AQain ~t]Qw Map Building Schematic Unavailable Estimate Taxes See TaxJ;olle~9LilltQrmation_:._Current/Delinquent Taxes Frequently Asked Questions PareellD 02-26-21-0290-00000-0060 (Card: 001 of 001) Classification 10 - Vacant Conmercial Mailing Address Assessment (totals) RYMAN KEVIN L & TAMMY L & Ag Land $0 RYMAN NaSON L&DOTTIEA Land $96,652 37325 STATE ROAD 54 Building $0 ZEPHYRHILLS, FL 335426960 Extra Features $0 Physical Address 6937 MEDICAL VIEW LN Total Assessment $96,652 ZEPHYRHILLS, FL 33542-6648 Save Our Homes $0 Legal Description (Fnt4lines) $96,652 DAUGHTERY ROAD PROFESSIONAL Taxable Value CENTER III PB 53 PG 024 LOT 6 OR 5532 PG osn Land Detail (Card: 001 of 001) Line Use DescriDtion Zoning Units Type Price Cond Value 1 1000 COMMERCIAL OOOP 12,000.00 SF 5.17 1.00 $62,040 2 1000 COMMERCIAL OOOP 12,102.00 SF 2.86 1.00 $34,612 Additional land Infonnation Aeres I 0.55 I Tax Area I 30ZH I Fema Code I - I Comm Code I PDRP1AA Building Infonnation Unimproved Parcel 0 Extra Features (Card: 001 of 001) Line I DescriPtion I Year I Units I Value Sales History Previous OWner N1A Year Month Book I Page Type Amount 2003 09 5532/0577 WD $0 Search AQain Show Map Building Schematic Unavailable Estimate Taxes See Tax Collector Information - Current/Delinquent Taxes Frequently Asked Questions http://appraiser.pascogov.com/search/offline _tca.asp?Sec=02&Twn=26&Rng=21&Sbb=0290&Blk=0000... 2/21/2006 1111111111111111I11111111111111I1111111111111111111111111111 2006041050 NOTICE OF COMlVlENCEMENT Permit No. Parcel I.D. No. 02_26_21-0290-00000-0060 Rcpt: 974151 DS: 0.00 03/01/06 Rec: 10.00 IT: 0.00 ---------- Dpty Clerk State of Florida County of: Pasco i~~~~~~MA1Nri'1P3ASCO COUNTY CLERK I. . pm 1 of 1 OR BK 6861 PG 1388 THE UNDERSIGNED hereby give notice that the improvem.ent will be made to certain real property in accordance with Chapter 713. Florida Statutes, the following information is provided in this notice of commencement. 1. Description of property (Legal description of property and address if available): Daughtery Road Professional Center _ Lot 6 _ 6937 Medical View Lane, ZepbyrbiUs, FI 33542 Pareel #02_26-21-0290-00000-0060 2. General description of improvements: INSTALLATION OF A FIRE ALARM SYSTEM 3. Owner information A) Name and address: Kevin & Tammy Ryman and Nelson & Dottie Ryman - 37325 State Road 54, ZephyrbUls, Fl 33541 B) Interest in property; Owners C) NaIIJe and address of fee simple titleholder (if other than owner) R 4. Contractor: A Total Solution, Ine, - 3531 Keystcne R.d, Ta!'pon Sprtngs~ Fl34688 5. Surety a) Name and address b) Amount of bond 6. Lender (:name and ad~ess) 7. Person within the State of Florida designated by ownernpon who notices or other documents maybe served as provided by Section 713.13(10(11)(7), Florida Statutes. Name and address: 8. In addition to him or herself, o'WD.er designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statues. 9. Expiratr..m date of notice of connnencement of recording unless a different date is specified). (The expiration date: is one year from. the date STATE OF FLOP.lDA COUNTY PASCO A_Signa-'~~VO Tltlc,~er Please Print: f{e 0 (v\.., Q~~ Title: ~e.r . ,r T~Y'ollo:ving ~ment was acknowledged befor.e me this. . Js,. day of ffi ('~~ ~ u l "'-- ~ \ 'M..c~ who is peJ:~!l.1lJh: ,tglg:vvn to me or who produced as identification. -' 2006, by After recording, return to: Name: A Total Solution, Inc. Address: 3531 Keystone Road City: Tarpon Springs, 1"1 34688 Notary signaturr;; Name (print) Title or rank Serial number, if any i"'Y "~c. . 't;,~ r; ~~,; '> o. ,,0 Notary Public State of ~'orida Bobble J Knight ~y Commission DD416222 c:xplres 03/31/2008 10110 391i'd NOIlnlOS lli'lOl Ii' 5!5SEP5LGL 80:G! 900G/!0/E0 A TOTAL SOLUTION, INC 3531 KEYSTONE RD TARPON SPRINGS, FL 34688 FIRE ALARM LICENSE: EF0000441 LICENSE HOLDER: JOHN S. ROBINSON PHONE NUMBER: (727) 942-1993 PROJECT: DAUGHTERY ROAD PROFESSIONAL CENTER 6937 MEDICAL VIEW LANE ZEPHYRHILLS, FL. DESCRIPTION OF WORK: NEW FIRE/SECURITY ALARM SYSTEM V.\/~" ~uuo .L...~.L ...&.. -.......... ...... --.-- _._-~. ~').~ m M Jeff GIlleSpie 18711 CIUNIlle Roed Lutz, FIOI'Id8 335M A TOTAL SOLUTION~ INC. , TotIlSy-.s&Il~....~~.Deti&IlIDd~ FJIC AJarDllPile .s,r~ I~BY*iIII' Seadly.AJIna IAI:rIts CGIIDol/ CC1'V (daM circt* TV) I Name c.a _1IBrCCm S. File Spk'....1..iea8 f:923S3800012OO2 S. PireAImR Ua 11,11 ,1E1'OOOO441 WWW.~COII1 "'ONE CALL DOES IT AU: Quote No: Date: Page: 8117 1127t2006 1of3 AttentiOn: A Total Solution. Inc. is pI....d toolfet ..foIcMInQ....... ayst8minStaltatian proposel8t the locaBon,DaIghIery Road PltAeuloneI Cent*' BUild. 8 'All equipment inStalled by ATS meets the NFPA 101 (2O(3), NFPA 72(2002) standardS and the AuthOrItY HaYing Jurtscldlon The propo88IlS as fOllOWS; ou.tItv 1 2 2 2 2 2 3 4 8 5 13 2 9 1 1 1 3 1 EauiDm8ld:. . . Securtly QOhbol peneI~. bt8d ror ftNand IS 'menuf8CbJr8dby the Bosch G Bo8Ch keypad 12fN Circuit ProteQOl' PhOne LIne S&qt'Protector Photo EleetJtc Smoke. Detector Smoke DetectOr.s.e Relay - plug in Fi~ Pull StatiOn DoUble ActIon MultI-c&nde18 AudIble Vleu81 Device Visual Device MullICan 8tn)be GIae8 bnNIk ~.., VIIUe pp magnet contact Bosch, dull tech .rtIC)tJOn. detecIor SecuriIy swItdI. ntc ATW urace mount indoOr siren Auclble VI.... DeviCe Outdoors OdD Popit 8 ZOne ' GlasS br88Ic. flC:CO\8Ic Auclble Vi.... WIIlerprDOf Box Black The cost for this installation wiD be . $9."'7.31 ; This price includes "I perta (including cable. bOxes, end htrdW8fe). labOr, ~mtta and sI8te sal88laxlf applicable. 351IUI$,lQeJilOlU)'f~~ ~~7t1$ I.OCAL('7'17)96I_CDI11W.~I~' PAX(7.l7)",""" S' iI m A TOTAL SOLUTION, INC. ToIal s.-~.itiaD,"J~ ~ DesiaD -1IIIspectioDs FIR AIIna,FiIe ~ I FiR: By.kIII f.SclCdy AJIrm JA<<:ess CODtroll CCTV (... c:inU TY)'/N1ne c.a _18IaCCm St8teFite'.~iIIiIra.~.m3S3800012002 '5_ Pile AJlmaLk _1.1I!'FOOOO441 """"'.lIatUaIaIiaD.oom "ONE CALL DOES rr ALL" Quote No: Date: Page: 6117 112712006 2of3 Jeff GUI8SPie 18711 Ct8ille R08d Lutz. Florida 33558 The customer Is responsible for provicIng a 120 volt dedIaded cirCI.it for the fife atarm system and necessary eleclriC81 boXeS iMtalfed. Tn8 fire alarm system win have a oneyearW8l18nty on parts and 1IIbor. The W8I18nty will be voided if theeystemis fotMto be milU8ld CI abused and/Or an act of nature occurs. PIeae allow 4 to 8 weeks for ,:>&rBlllino. (if required) PermIt feel are subject to change. ThIs proposal is for the installation of .. approved flr8I8ecuritycoubol system for your new Business Occupeney. The security and fire ...-m devices.ll bemenuf8Ct1nd:by .... Boech Group. The fire..... system (Per COde) wt~be consist of.. ,... st8tion.. audible vi8uaI devices end smoke d8teClors ewer the fire control"" and .....ncIator. The security aystem wiI have .,..... ccwerege a.t wilt COR8i$l qf windOW switches. door ewltch88 8nd 91'" bnNIk detection. Two IYM)tiOn ctM8ctors will. be inllalled In critical .... The customer is responeibIe for providing (1) 110 volt dediQated ciraIit for the securitrlfire ..ann system. 3Dl Dtt'IQiiIlSIOM> rM.fC*~ R.GaM""'7115 LOCAI.(1'I7)"'I. CSN'I'IW.R.OmDA.~ FAX(J2'7)PG4P" UA'~"~UWW .,.~. ". -. .------- m D m A TOTAL SOLUTION, INC. T_s,-.~ "~~~.SIaIrI, ~1Dd~ fire AIM'IIl/Fue SprW.1er I rile ~, ~ AIItDl/A<<ess COQU'Ol/ cctV (cIaRd cirC1Iit TV)/NaneCIII ... ~ s.. &eSprWder J ~m353800011002 S.. FnAlllmlJcaM moooo441 ",",.IItIaIaIIobioD.eGIl -oNe CAll DOeS IT ALl" Quote No: Date: Page: 5117 112712006 Sof3 Jeff Gillespie 18711 ChaVtlle R08d Lutz. Florida 3S558 lnaatlation Pavm8N SdMMiulf: 10% Upon 8ccept11K:e of COI"IIl'8Cl 4Q4J(a When aH eleclrlCIII pre ~re hesbeen completed. 4CJIKt When'" syetein deYiCee and herdw8re..... inatelled and tesI8d. . 101J6 Once the system is completed and signed Oft by the CU8tomer. This proposal is valid for 30 days. If you should h8Ye any questi0n8. ple..gtve me a ell, Sincerely, ~ f..JA , Ch8rfie RJ'~ Director of Sales AcoeptMce: ~.~:s ~hQ..9~ I ,I. . ?~~d. fa.1job J I'-? /~ ". -- DIlle q<tlj7 ~ J,W Conbad Amcu'It $9,847.31 3"1~.._ROAD TAIIPOt(I.PIDN08, ~MAl-71U J.OCAL(727)HJ.Itt3 CDI'I'&M.JII.C:IaM 1.-..uw.RU PAX ('m)!Il\G.,,- 49 Sec:urtty Systems Battery Calculation Worksheet InstrudIoIu: ftIIln # ..... Qulmtity data fIeWa BOSCH DAUGHIERY ROAD PROFESSIONAL CENTER (rwnnt VlII_ wUl be m:,..-ed In mAl DnIre FIRFlSECURITY PANEL UL USTED REMOTE NAC POWER SUPPLY PHOTO SMOKE DETECTOR. 01260 KEYPAD o o #N/A o o o o o o o o o o o o o o o ....., -.A. ..... DnIre 200 ISO 20 104 o o 0.1 o o o o o o o o o o o o o o o Alarm IlIA Per Dnke soo SSO 3S 100 o o O.S o o o o o o o o o o o o o o o TataI Dmce SCluld mA 200 3.SS 60 208 o o 3.2 o o o o o o o o o o o o o o o 475.t5 TataI DevIce AIann mA SOD 8S0 10S 206 o o 3.2 o o o o o o o o o o o o o o o 166U ,L.~ - /- "I. tl, Z~~6 #//8P"Z Prod. 10 09412G-B . Components The D9412G-B is a Fire/Burglar package that includes: . one D9412G board . one D1640 Transformer . one D8109 Fire Enclosure with D 1 01 F Lock and Key Set . one D122 Dual Battery Harness . one D928 Dual Phone Line Switcher . two D161 7 ft. (2.1 m) Dual Modular Phone Cords Prod.ID D9412G-C . Components The D9412G-C is a standard Commercial Burglar package that includes: . one D9412G board . one D1640 Transformer . one D8103 Enclosure with Dl01 Lock and Key Set The D9412G Control Panel provides an integrated solution for Access Control, Security, and Fire Alarm system applications. The control panel can monitor alarm points for intruder alarms or fire alarms while operating user command centers and other outputs. The control panel includes a built-in communicator that reports events to selected PSTN or IP network destinations through four programmable route groups. The D9412G Control Panel provides eight on-board detection points and up to 238 off-board detection points. It provides 128 relays, and up to eight access control doors. Grant access from a Wiegand style card reader connected to: a 09210B Access Control Module, a request-to-enter or request-to-exit input, or a command center. . Control Features . Eight on-board detection points and up to 238 off-board detection points . 128 relays . Eight access control do.ors . 8 programmable areas with perimeter/interior partitioning . Real-time clock and test timer . Up to 1000-eventlog (including event modifiers), including time, date and event with area, point and user number . Battery charging circuit, AC power and voltage supervision . Automatic reset circuit breakers . Lightning and EMI suppression . Power limited external circuits . Communicator Features . Built-in digital communicator with phone line monitor (loop or ground start) . Multiple telephone numbers, primary and duplicate paths with main and alternate destinations . All reports within each of four route groups are programmable . Optional dual phone line switcher monitors two phone lines . Optional network interface module for bi-directional communication over Ethemet networks . Automatic test and status reports . Time windows for arming and open/close report suppression . Programmable answering machine work-around for remote programming on shared phone lines . Functionality Programmable outputs . 2 A alarm power @ 12 VOC . 1.4 A auxiliary power @ 12 VOC . Four alarm output patterns . Automatic bell test . Programmable bell shut-off timer The 09412G Control Panel provides up to 246 individually identified addresses. Each address accommodates normally open and/or normally closed devices with end-of-line resistor supervision. Each point is programmable for fire, fire supervisory, or burglary applications. System response . 31 custom point indexes, including fire supervisory . Selectable point response time . Cross point compatibility . Fire alarm verification . Fire inspector's local test . Watch mode . Scheduled events (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door access and more User interface . Supervises up to eight command centers (up to 32 non- supervised command centers can be used) . Custom command center text . Full function command menu including custom functions . Each user has authority by area and 16-character name . Fourteen custom authority levels control user's authority to change, add, delete passcodes or access control tokens/cards, disarm, bypass points, and initiate system tests . Adjustable brightness/volume for command center display/ sounder Note: At least one command center per system is recommended, Area configurations Area programming offers a wide selection of different system configurations. Each area has an account number to define annunciation, control, and reporting functions, Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master/associate). Security you can rely on BOSCH U~erpassCodes Each passcode individually programs with three to six digits in length and no fixed digits. Each user is assigned one of fourteen customized authority levels in each area. You can program passcodes to operate only during certain times. Each user can have a 16-character custom name. You can view, print, and report the user's name to a central station in Modem IIIa2 Communications format; you can retrieve a user's name with Remote Account Manager (RAM IV) software. Security and fire detection The D9412G Control Panel provides eight on-board detection points, and up to 238 additional off-board points (depending on model and expansion interfaces). You can program individual points to monitor devices such as burglar alarm devices, fire alarm devices, and supervision devices. Event log storage, viewing and printing All local and transmitted events (up to 1000 total events) are stored in a log. The event log includes time, date and event, with area, point and user number. Users can view the event log from Alpha Command Centers. The Remote Account Manager (RAM IV) software can retrieve events from remote sites. With the correct printer interface module installed, the D9412G Control Panel can use up to three on-site parallel printers. The Event Log and a local printer can provide a record of openings and closings without extra communications costs. RAM IV operators can retrieve events periodically using one phone call, rather than receiving several calls each day. When the control panel's event log reaches the storage limit, it can send a report to a receiver. This report reminds the central station to retrieve events from the control panel's event log. You can store, view, or print access events such as: . Access granted . No entry . Request To Enter . Request To Exit Access Control . Custom door strike, point shunt and auto disarming response by area . Logging options for: Access Granted, No Entry, Request to Exit, and Request to Enter . Fourteen panel-wide access levels with both manual and scheduled control Scheduled events (Skeds) The D9412G Control Panel's' internal clock and calendar help the panel(s) operate individually scheduled events (Skeds). Skeds perform a specific function such as arm/disarm, relay control, or point bypassing. The D9412G Control Panel offers: . 64 scheduled events with up to 26 different functions . Day-of-week or date-of-year schedules . Four holiday schedules of 366 days each (leap year) Fire test When a user activates Fire Test Mode, the control panel suppresses reports to the central station. Fire Test Mode activates with a passcode at the command center. All testing data is visible on the command center and annunciator during testing, An automatic sensor reset feature saves you time; you do not need to reset the sensors manually. At the end of test, the command center shows the number of untested points, Programming, diagnostics and controls Users can program all system functions on-site through a D5200 Programmer, or remotely through Remote Account Manager (RAM IV) software. A programmable system passcode prevents unauthorized remote programming. The control panel accommodates up to four separate telephone numbers for primary, alternate and backup receivers for automatic test reports. A name and number identifies any user who resets alarms or any user who arms or disarms a system. III Approvals UL Standards UL365, Police Station Burglar Alarm Units and Systems UL609, Local Burglar Alarm Units and Systems UL864, Control Units for Fire-Protective Signaling Systems UL985, Household Fire Warning System Units UL1023, Household Burglar-Alarm System Units UL1076, Proprietary Burglar Alarm Units and Systems UL1610, Central-Station Burglar-Alarm Units UL 1635. Digital Alarm Communicator System Units Approvals FCC: AJ9MLU-46532-AL-E Factory Mutual CSFM: . 7165-0801 :123, Control Units - Non-High Rise . 7170-0801 :175, Control Units - High Rise . .Specifications . Hardware Accessories Back box and polished brass faceplate, Used with: D279A, D720, D1255, D1256, 01257, 2 TelCo lines D928 Dual Phone Line module required for two phOlte lines D8103 Universal D8108A Attack Resistant D8109 Fire Back box and stainless steel faceplate Used with: D279A, D720, 01255, 01256, 01257, Back box and polished brass faceplate used with D1260 Alpha V command center, 246(8 on-board, up to 238 off- board) Back box and stainless steel faceplate used with D1260 Alpha V command center, I 249, plus 1 service passcode Portable desk stand in smoke colored Plexiglas. Used with D279A/AW, D720/W/R, D1255/WI R, D1256, D1257, D1260, ",-,.\fiL ~. ~-- - 2A@12VDC 1.4 A @ 10.2VDC to 13:9 VDC White surface mount box for installations requiring conduit to a command center, Command centers mount on conduit box, Dimensions (H x W x OJ: 12 cm x 21 cm x 3 cm (4,56 in, x 8,25 in, x 1,05 in,) 12 VDC 16.5 VAC 40 VA two plug-in transformer (D 1640) Up to two 12 VDC, 7 Ah sealed lead acid rechargeable batteries Up to two 12 VDC, le Ah sealed lead acid rechargeable batteries Red surface mount box for installations requiring conduit to a command center, Command centers mount on conduit box, Dimensions (H x W x 0): 12 cm x 21 cm x 3 cm (4.56 in, x 8,25 in, x 1,05 in,) - Self-contained independent point control allows individual points to be armed and disarmed separately from the rest of the system. Includes one user-programmable pass code and built-in panic button. A single zone can be branched into one instant loop and one delayed loop. Can initiate opening and closing reports from a single control panel point. Includes built-in form C relay, entry delay buzzer, one delay loop LED, one instant loop LED and one armed LED. Available in off-white, Self-contained independent point control allows individual points to be armed and disarmed separately from the rest of the system. Includes one user-programmable pass code and built-in panic button. A single zone can be branched into one instant loop and one delayed loop. Can initiate opening and closing reports from a single control panel point. Includes built-in form C relay, entry delay buzzer, one delay loop LED, one instant loop LED and one armed LED. Available in white. Low profile digital command center with backlit keypad, Annunciates system status with indicator LEOs and piezoelectric sounder. Individual point- status LEOs indicate condition of up to 8 points including fault, alarm memory and bypass. Includes 3 programmable one-touch function keys, and a four-wire connection. The 0720 is off- white, Low profile digital command center with backlit keypad. Annunciates system status with indicator LEOs and piezoelectric sounder. Individual point- status LEOs indicate condition of up to 8 points including fault, alarm memory and bypass. Includes three programmable one-touch function keys, and a four-wire connection. The D720W is white, Low profile digital command center with backlit keypad. Annunciates system status with indicator LEOs and piezoelectric sounder. Individual point-status LEOs indicate condition of up to 8 points including fault, alarm memory and bypass. Includes three programmable one-touch function keys, and a four-wire connection. The D720R is red, Digital arming station that illuminates when keys are pressed. Provides a 16-character vacuum' fluorescent English-language display, and a built- in speaker with distinct warning tones, Permits remote control of relays and real-time clock display, as well as for adding, deleting, changing pass codes, and system tests, The 01255 is off- white, Digital arming station that illuminates when keys are pressed, Provides a 16-character vacuum- fluorescent English-language display, and a built. in speaker with distinct warning tones. Permits remote control of relays and real-time clock display, as well as for adding, deleting, changing pass codes, and system tests, The D1255W is white, Digital arming station that illuminates when keys are pressed, Provides a 16-character vacuum- fluorescent English-language display, and a built- in speaker with distinct warning tones. Permits remote control of relays and real.time clock display, as well as for adding, deleting, changing pass codes, and system lests, The D1255R is red, Digital fire alarm control station with 16-character vacuum-fluorescent. alphanumeric display, Provides system control over fire areas, housed in red plastic, annunciator programmable text identifying specific alarm, trouble and supervisory conditions. . Housed in red plastic, display 16-character customizable English text identifying devices and point of alarm. Housed in red plastic, annunciator programmable text identifying specific alarm, trouble and supervisory conditions. For use in public places, Does not provide system control. Digital arming station illuminates when keys are pressed. Provides a four-line by 20-character LCD English-language display and a built-in speaker with distinct warning tones, Features eight soft keys, Resembles an ATM-style user interface, Permits remote control of relays and real-time clock display, Allows users to perform system tests and add, delete or change passcodes. Portable hand-held local programmer. Operates on four C cell batteries (included). Expanded storage capability allows additional handlers and records to be stored. Portable laptop programmer used for on-site programming and contains all hardware necessary to program the system. . Provides five A-rated contacts for switching auxiliary voltages and currents. Provides two form C dry outputs, polarized relay coil operates on 12 VOC or 24 VOC. . Accessory relay for control panels and modules, Maximum rating is 1 A @ 24 VOC or 2 A @ 12 VOC. Available individually (0136) or in a package of 25 (0136-25). - Provides phone line supervision and five alarm zones plus on control output. Compatible with OCX systems. Includes mounting bracket for 08103, 08108A, or 08109 Enclosures. The 0161 and 0162 Modular Phone Cords are required, The 08121 A is not Ul Listed. - Provides phone line supervision and five alarm zones plus on control output. Compatible with OCX systems. Includes mounting bracket for 08103, 08108A, or 08109 Enclosures. The 0161 and 0162 Modular Phone Cords are required. The 08122 has the following Ul Listings: Ul365, Ul464, Ul1610 and Ul1635, Ul1076, and Ul864. ." - '~..! .~_. ,titi! Provides a multiplexed data backbone for point expansion. Used with 09127T or 09127U POPITs or addressable detectors with built-in POPITs, Dimensions (HxW): 76 mm x 127 mm (3 in. x 5 in.), Eight POPITs built into one OctoPOPIT. Can be used in conjunction with POPEX and POPIT, but does not require POPEX (08125). OctoPOPIT may not be suitable for fire supervisory devices or fire initiating unless interfaced with 01258 or 0129 modules, Use with G Series Control Panels on ZONEX 1 (or ZONEX 2 on 09412G Control Panel only). .. .... Contains eight dry-contact relay outputs, each relay is Form C rated at 1 A at 12 VOC, relays can be operated manually either through the command center, or remotely from the central station using RAM IV. Relay response can be programmed for automatic operations using various pre-programmed parameters within the panel. A 38 mm x 76 mm (1.5 in, x 3 in,) hardwired module that provides individual annunciation of alarms, troubles. restorals and missing conditions relating to a unique detection device, POPITs are wired in parallel on the 08125 data backbone, Each detector loop is supervised with a 33 kilohm EOl resistor, Up to 238 POPITs can be connected to a 09412G, up to 67 for 07412G system, Requires the 08125 POPEX Point Expander, Includes a magnetic tamper switch, A 38 mm x 76 mm (1,5 in, x 3 in,) module that provides individual annunciation of alarms, troubles. restorals and missing conditions relating to a unique detection device, POPITs are wired in parallel on the 08125 data backbone, Each detector loop is supervised with a 33 kilohm EOl resistor. Up to 238 POPITs can be connected to a 09412G, up to 67 for 07412G system, Requires the 08125 POPEX Point Expander. Does not include a tamper switch, e Module A four-wire parallel printer interface that can be mounted up to 305 m (1000 ft.) from the control panel. Prints 80-character, single-line information including: date, time, event, account number, area number, user 10 with text, point # with text and access events, Connects to a standard parallel printer via a standard parallel cable. Serial Device Interface (SOl) bus device used for bi-directional serial communications, Communicates at 300, 1200, 2400, 4800, and 9600 baud, (n---~! v~ ,. ,:$ Optional lock and key set for use with the 02203 standard enclosure and the 08103 optional enclosure. ~~wll -- Screw-on tamper switch that will fit all enclosures. Shipped in packages of two, Used to mount accessory modules in 08103, 08108A, 08109, and 08109L enclosures. Used to mount accessory modules in a 09101 enclosure. 0161: 2.1 m (7 ft,) 0162: 61 cm (2 ft.) Steel enclosure measuring (H x W x D) 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3,5 in.). 1,2 mm (18-gauge) grey, cold-rolled steel enclosure measuring (H x W x 0) 41 cm x 41 em x 9 cm (16 in, x 16 in. x 3.5 in,). UL Listed for Central Station Fire, Local Fire, and Remote Station Fire applications, Lock and key set included, Requires use of 02402 Mounting Plate. Mounts inside 08103, 08108A, and 08109 enclosures. Can accept up to six standard 7.62 cm x 12,7 cm (3 in. x 5 in.) cards, The 05500C-XXXX Remote Account Manager Windows<l!) (RAM IV) Software Package allows computers equipped with a Microsoft"') Windows@ operating system and a modem to program, store records. control, and troubleshoot control panels, The package supports the following control panels 07212, 07212Bl, 09112,0911281, 09412G, 07412G, 07212G, 08112E, 08112E1, 08112G, 08112G1, 08112G2. 08112A, 04412,06412,02012,02112, 02212, 07024, OS9400, OS7240, and OS7220. Check with Customer Service for a current list of supported products, The package includes the software on CO, the license disk. and the 05370 RAM Security Block. The 05500C.XXXX.LTE Remote Account Manager for Windows"'" Lite (RAM IV Lite) Software Package allows computers equipped with a Microsoftilll Windowsilll operating system to manage accounts and locally or remotely program control panels. The package supports the following control panels: 07212, 07412, 09112,09412, 08112E1, 08112G2, 0911281, 0721281, 06412, and 04412. Check with Customer Service for a current list of supported products. The package includes the software on CO, the license disk, and the 05371 RAM Security Block, The 081280 OctoPOPIT (Point of Protection Input Transponder) module combines the functions of the 08125 POPEX (Point of Protection Expander) module and the 08127109127 POPIT modules to provide 8 off-board points in a single module. The 081280 OctoPOPIT and 08125 POPEX modules can be wired in parallel to the ZONEX Bus terminals on the same panel. System Overview The module can be installed inside the enclosure of the control panel, or the module can be installed in a separate enclosure and connected to the panel. Features . Provides point identification of initiating devices . Expands the number of points in the system . Oipswitch programmable Basic Functions Address switches There is a set of dipswitches to set point assignments and line termination. Switches 1 to 4 assign the sensor loops to point numbers on a compatible control panel. Switch 5 sets the line termination. Point dipswitches Activate or deactivate each point connected to the module by turning its respective dipswitch to the closed or open position. The point dipswitch can be used to deactivate conflicting points. 165 Certifications and Approvals I;i{- U L Standards UL1610, Central-Station Burglar-Alarm Units UL 1635, Oigital Alarm Communicator System Units UL464, Audible Signal Appliances UL609, Local Burglar Alarm Units and Systems UL 1023, Household Burglar-Alarm System Units UL985, Household Fire Warning System Units UL 1076, Proprietary Burglar Alarm Units and Systems UL864, Control Units for Fire-Protective Signaling Systems Planning If the module is installed in a separate enclosure, it can be placed up to 200 ft. (61 m) from the control/communicator. The module can be wired to the control/communicator using the module's terminal strip or using Molex connectors, The Molex connectors are useful when multiple 081280 modules are in use. The terminal strip is easier to use in cases when the module is connected directly to the control/communicator. Each module uses 51 mA (worst case), which can affect the number of units that can be connected on a single wire run. Apply the wiring considerations provided in Technical Specifications. Technical Specifications 07212Bl, 07212, 07412, 07412G, 0911281, 09112, 09412,D9412G For modules installed 200ft. (61 ~)'irom the controll communicator: Standard4-conductor 22 AWG (0.8 mm) shielded wire 10.2 to 13.8 VDC, supplied by panel (. " 07038 Remote HAC Power Supply Specifications Features . Remote NAC Power Supply will 6 A of notification power . Outputs can be configured for NAC output or constant auxiliary power . 4 Class B, Style Y Circuits . Multiple output patterns . Ground fault indcation . Regulated 24 Volt output (nominal) . Over current protection . Charger control monitor . Supervision of AC, battery and circuit expander . Fully supervised outputs . Compatib/e with 1he following Radionic$ con1rols: 07022 FAcp, 07024 FIf8 Alarm Con1rollComnulicator and the D8024, 09024 and 010024 Analog FACPs Description The Radionics 07038 Remote Notification Appliance Circuit (RNAC) Power Supply is UL Usted to be used in commercial fire alarm applications. This regulated power supply provides up to six amps of power that are used to recharge batteries and operate boll continuous and intermittent alarm loads. This six amps of power can be distributed through 1he four Class B, Style Y circuits that are part of the 07038. It is also compatible with any UL Listed control unit utilizing reverse polarity supervised notification outputs using 24 we regulated ouIpuIs. The 07038 is provided in a red enclosure that houses the power supply board and standby batteries. Ample room is provided inside the enclosure to make AC power connections and route field wiring to comection points on the power supply board. All wiring is connected to the power supply board via sa8W terminals that can accept up to #12 AWG (2.3 rom) wire. The 01038 can be connected to 1he 07024 via the four wire connection to the Option Bus. This connection provides individual control of each output by the 07024, and complete supervision of !he power supply. The following options can be set with !he DIP switches: Option Bus Address, NAC Input Variable and AC Faikn Tune Delay. The NAC Input Variable option allows for split functioning of the 01038's inpuls. Input 1 can either be set to drMt all folr' NAC outputs, or NAC Outputs 1 and 2. If the latter option is chosen, then Input 2 will drive NAC Outputs 3 and 4. There are seven local status display LEOs on the 07038 board that monitor the following conditions: High Voltage, AC OK, Low Battery, Loop Trouble,. Ground Fault, 0uIput Active and NAC Short. 07038 Remote NAC Power Su Application The 01038 is designed to add four additional notification appliance circuits (NFPA 72, Class B, Style Y) to a fire alarm control panel. The 07038 can be used with other fire alarm control panels. Supervision and control is provided through a supervised, polarity reversal output (depending on the panel that is in use). For the D8024, 09024 and 010024 analog panels, Ile 01038 connects through a NAC circuit. No serial bus connection is necessary. The 07038 can also be used as a power supply for fire- protective signaling systems. Installation The 07038 power supply board and enclosure are shipped in one box. The 01038'8 enclosure should be mounted in a convenient location for servicing and maintenance. The power supply board must be mounted in the enclosure using the provided hardware. Primary power (120 V AC)from an unswitched decIcated branch circuit is routed to !he power supply enclosure and connections are made inside. Field wiring to control modules or continuously powered devices are routed into the endosure via knockouts provided on !he enclosure. When all circuiIs are determined to be free of earth grounds and wire-to-wire shorts, connect the primary power to the supply and then install the batteries in the locations provided in the enclosure. $ radionics A member of the Bosch Group Specifications ..........'...... . ..........> ,.....,.>>")..:.5 ..': 0penIIlng TemperalIn +32"F b +12O"F (O"C b +49"C) Input Power 120 V/IC. eo Hz. 25 I< BaIlery VoIage 24 VDC, ___ (20.2 b 28.0 VDC) Max, BalIery Capaclty 38M 0Ulput VoIIage (AC 0penIIl0n) 27.4 +1- 0.1 VDC @25"C (77"F) OLdput VoIIage (DC 0peraIian 24.1 +1- 0.6 VDC @ 25"C (77"F) Total 0Upul Cl.nenl 6A RWe VoII&ge s250mV... Enclosure Dimensions (wIo doer) 14.8 In, Wx20.41n. Hx4.11n.0 (38anWx52an H x 10.4 an 0) Input VoII&ge Input to 0ulpuI Response TIII18 EOl Resisklr 9ID 30 VDCNRMS s 50ms User suppled . . h:.,. .... Standby VaIlage -5.0 VOC EOL ResislDr 2.2K oIlms +1- 5% OUIpUI VoIIiIgB 24.1 or 'Z1 A VOC) Rated Oulput Cunent (per oulpla) x 4 1.5 A Max. 0uIpul per Cln:uIl 2.51< Max. 0uIpul b' All Cln:uI!s 6.01< t I -7-~~rj~ 850 1M "1J: ' 24.1 or 27 A VDC 1 I ==~r~ ..; .1(' ,'. Fonn "C" 1,5A@32VOC Listings and Approvals · UL 864 Listed Control Unit Accessory . UL 1481 Listed Power Supply for Fire-Protective Signaling Systems . CSFM . NYc-MEA Ordering Information .~iIIJ" " , 0126 12 V, 7 Ah Battery 12 V, 24 Ah Battery 12 V, 38 Ah Battery Rsrnole NAC Power Supply 01224 01238 07038 Red 07038 Remote NAC Power Supply Board @ 2001 Radionics, a division eN Detection Systems, 100. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5801 80_& ceRrflCAlE NO. AIl1;J7 PIN: 381880 Specifications L960 8J01 01038 Page2of2 DSMs-sAWK DSMS-SATK DSMs-DAWK DSMs-GR Single Action, Leeds, Key Single Action, Terminals, Key Dual Action. Leeds, Key Dual Action, Termin8IS. Key Note: AI modElIs aN shipped with one SCOI8d aayIIc brelIkRld and one key THe DSMS is a high quality, die-cast metal Fire Alann Pull Station available in either single or dual action configurations with SPST gold contacls, key resets, and either Wire lead or tenninal strip connectionS. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the Americans with Disabilities Act (ADA). . Features · Singte or Dual Action · Key Reset · Wwe Leads or Terminal Connectors · Gold Plated SPST Contacts . Mounts on Slandard Single Gang Box . Surface and Weather-proof Backboxes Available · High Gloss Red Enamel Finish . Scored Acrylic Breakrod · ADA Compliant · UL Usted, CSFM Approved . Basic Function Operation . The DSMS Series is operated by pulling the handle on the front of the station as far down as it will go, at which point the handle locks into place and is easily visible from up to 50 ft. (15 m). The handle is reset by opening the station with the key, placing the handle in the normal upright position and re-Iocking the station. On the action models, the push bar rotates inward allowing the Pull handle to be grasped in a one handed motion. . Certifications UL 1.is&1g S6650 CSFM 7150-1062:124 ~l detection systems A Member of the Bosch Group . Wiring . Optional Accessories l! ll~ 1loo-!! ! ~: o III .. . .. ~ I ~ et "- :ell. .:g u." ,28 i !i -00] i io:: o IU .- . ..J 'D ~ .! ~ U :J ~~ . Technical Specifications AI models mount on a standard single gang baCIcbox, model DSMS-8B interior surface meI8I b8cIdloK, or DSMS-WBB weeIher proof bacIcbox 1 Amp . 30 VDC or 120 VAC 4.75 In. H x 3.25 In. Wx 1.1 in. D (12 em H x 8.3 em Wx 2.8 em D) 4.75 in. H x 3.25 in. W x 2.25 in. D (12 em H x 8.3 em W x 5.7 em 0) Body: Red wiIh raiSecI while letters. PuR Bar: White wiIh red taised lelfIers. PIN 457910 DetectIon Systems. Inc. 130 PerinIon PaJkway, Fairport, New YOItt 1~9199 (585) 223-4060 . Cusl Service (888) 289-0096 Fax: (585) 223-9180 . Faxb8ck: (800) 315-0470 11 Fire I F220 Photoelectric Smoke Detectors F220 Photoelectric Smoke Detectors ~ S~cur!:; S,s:er^'s Fe8tun. . Two- or four-wire bases . Use with 12 VDC or 24 VDC systems . Optional CO-sensor, heat-sensor enhanced detection chamber . Oean chamber without removal or disassembly . QeanMe - signaling capability . Sensitivity rmdout on detector . Detector chamber compensates for dust build-up . Tamper protection . Dual-color LED 8MIc FundioI. Compatible Bases Configurethedetectorsintotwo-wireorfour-wire~s by selecting the appropriate DlOlDltmg base. These detectors are compatible with any of the F220-B6 bases: . F220-B6 Two-Wll"e Mounting Base . F220-B6R Standard Four- Wue Mounting Base . F220-B6C Four- Wue Mounting Base with Auxiliary Relay . F22O-B6E Power Supervision Mounting Base The F220 photoeIecIric smoke detectors are UL Listed, open-area photoeleclric smoke detectors designed for use with commercial fire protectiYe sig1aIing systems and household fire warning systems (see NFPA 72, the National Fire Alarm Code). These smoke detectors scatter IVrt umg a pulsed i1fmred source operatW1g with a gated, hVt-sPeed, photodiode i1fmred sensor. The syrnmeby of the optical chamber allows 3600 U'liform smoke entry, but mininizes extemallVrt entry. By using low CU'l'el'lt electronic circuitry, you can connect the detectors to a wide range of power source ci'cuits. Monitoring the Detection Chamber These detectors ~ several features that work together to maximize the pc tou.uance of the optical chamber: . Compensation: The detector monitors the chamber for the effects of dust build-up within the chamber and automatically compensates for these effects. If the chamber becomes contaminated beyond compensation, the green LED flashes every 4 see to indicate trouble. . Chamber Oleck- Self-diagnostics: The detector automatically indicates visually if the cah'bration is out of the tactory-listed range. This meets NFPA guidelines for sensitivity testing, because you can visually inspect the detector and check the flash rate of the LED. If the cahbration is out ofrange, the green LED on the detector flashes once every 4 sec. This indicates that the detector must be cleaned per the instructions provided with the detector. . OeanMe Mode: Indicates if the cahbration is out of the factory-listed range by sending a trouble signal to the OeanMe-companble control panel, if so programmed. BOSCH 21 F220 Photoelectric Smoke Detectors . Chamber MaicJIM: The detector has a unique. patent- pending cleaning mechanism. Use the valve on the back of the detector to insert the nozzle of a can of dean. dry compressed air. Clean the chamber with a short (1 to 2 see) blast of air. . Heat and Carbon Monoxide Enhancements The detectors areavaiJablewitb anoptionalfixed-k:Jll)'Q..:ture heat sensor or a combination of heat and CO sensors. These optional sensors enhance the operation of the smoke detector by reducing false alarms. . Carbon Monoxide: Without the presence of CO. a normal byproduct of combustion, the detection chamber is half as sensitive to smoke as a standard commercial photoelectric smoke chamber. This reduces false alanns. When the sensor detects CO. the detection chamber's sensitivity to smoke increases so it equals or exceeds that of a standard commercial photoelectric smoke chamber. . Heat: When the heat sensor detects a temperature rise. the photoelectric chamber becomes more smoke sensitive. The heat sensor initiates an alarm if the ambient temperature exceeds + 13S0P (+S70C). Dual-color LED A dual-color LED indicamrflashes green every 8 see when the detector has power and the smoke sampling circuitry is working. If CleanMe is enabled. the green LED double &shes (two flashes a half second apart) every 8 see to indicate normal operation. The LED turns red if an alarm is sent. After the alarm condition clears, reset the detector by interrupting its power. If the chamber becomes contaminated beyond compensation. the green LED flashes every 4 see to indicate trouble. Test Functions The F220 Photoelectric Smoke Detectors feature a unique magnet operation and sensitivity test fimction. Test the detector's operation by placing the magnet next to the detector's LED for three consecutive flashes. This causes the detector to send an alarm. Placing a magnet next to the detector's LED for at least one red flash but less than three flashes activates the detector's sensitivity mode. Tamper Deta:tion When detector heads are properly installed in any of the F220- B6 bases. tamper detection is provided by the wiring of the positive power line. The control panel initiates a trouble signal if a detector is removed from its base. A mechanical1amper lock comes with each base to prevent unauthorized head removal. Certlflc8tlons and Approvals Ustings and AppnMIIs: UROX: SmoIre - Automatic Fire Detectors (UL268) UlC-S529--02 Planning Compatible Control Panels . Two-wire: Refer to Technical Service Note (PIN: 4998148185). Note: Bosch Security Systems makes no claim written, oral. or implied that the F220 Photoelectric Smoke Detectors worlc with any two-wire control panels except those specified in the Control Panel CompatIbility chart in the Technical Service Note (PIN: 4998148185). . Four-wire: Compab.ble with all UL Listed four-wire control panels. Refer to the manufacturer's installation instructions for proper EOL resistor selection. Mounting the Bases Note: Consult NFPA 72 for proper detector placement. Depending on local regulations, the bases can be sur&ce mounted directly to four-inch square or octagonal electrical boxes and single-gang switch boxes. Warning: The volume of any electrical box used should be large enough to accommodate the number and size of conductors as specified by the National Electrical Code or any local Authorities Having Jurisdiction (AHJ). Loop Supervision Loop supervision require; one EOUOO or F220-B6E per loop when using F220-B6R1B6C1B6RC bases and is supervised by the control panel Wuing the Bases Note: Refer to the F220 Series InsudJation Instruaions (PIN: 4998138694) for detailed instructions. Screw Terminal Connections: Do not twist the wires or loop the wires around terminals. The wires fur terminal connection must be cut, stripped, and inserted as individual ends. Photoelectric detector head with heat and CO sensors only; requires base. Note: The CO sensor is not a separate detectoJ:. It enhances the operation of the smoke detector. Photoelectric detector head only; requires base. Photoelectric detector head with heat sensor only; requires base. Hardware Ac:cetlOries ..II:IIlllI_."liIJ )';'k . ." '0 ,.,".... . ..' ... .,1 ,1"".,1"1",...",, Order Number DRA-5 :,\;fl~;,Li\;,~W ,;;~),;>~:/ ;,;;,>,>,',.'.:-:-.;,: ;,j Provides remote annunciation of aIanns fur fire detectors. Voltage is 5 VOC. Current chaw is 10 mA at 5 VOC. Dimensions (H x W x D) are 4.8 in. x 3.1 in. x 025 in. (123 an x 7.8 em x 0.63 em). Order Number [Jf-2 ." Use the Uf-2 to remove. replace, or test the detector head by attaching the appropriate length ofhalf-inch diameter conduit (not supplied). Test magnet supplied. ~~~U~.I,l~~""; . Order Number EOL200 rlII Used with fOur-wire 12 VDC or 24 VOC systems fur power supervision. Uses a 22 ill EDL resistor. F220 Photoelecbic Smoke Detectors 13 'lIf~I..~ 'Iii ,If 'c....:.. .1:: : "'"''!i..''' .c.",c'~"','...:'7":'. ,,,.)k..l.,",.,,,....,. .... , .l.. . Order Number P.l2O-B8 "''>-,/:'::>''f Use the F220-B6 MOWlting Base with two- wire (12 VOC or 24 VDC system) applications. It is UL Listed when used in combination with the UL Listed. F220 detectors. Technical Spec:;itIadions F220.B6 Two.wire Mounting Base Power Requirements Cunmt (alarm): Limited to 20 RIA mininum at 8.5 VDC; 35 RIA maxi'num at 32 VDC. Cummt (standby): nominally 90 IIA at 12 VDC, 100 IIA at 24 VDC, and 120 IIA maximum at 32 VDC .. ,.,1 11I....;F~;l~:b_'~'-'h;i.:: , ' "'.'" . ,I ',', ". ". .f, H.' .'. ..... ,'. "," """ ,:., .Iy,.,..' Order Number F22o-B6R The F220-B6R MOWlting Base is the standard base fOr fOur-wire (12 VOC or 24 VDe) detector systems. It is UL Listed when used in combination with the UL Listed F220 detectors. Technical SpecifIcatIons F220-B6R Standard Four'wire Mounting Base outputs Alarm relay type: normaHy open (NO) and cIosea on alarm Relay rating: 0.5 A at 100 VDC Power Requinlments Current (aIann): 13.5 RIA at 12 VDC, 16.5 mA at 24 VDC, and 19 RIA maximum at 30 VDC Cunent (standby): nomineDy 90 IIA at 12 VDC, 100 I'A at 24 VDe, and 120 IIA maximum at 32 VDC Order Number F22o-B6C The F22O-B6C Mounting Base has a normally-open (NO) alann loop relay and a set of auxiliary contacts. It is UL Listed when used in combination with the UL Listed F220 detectors. 41 F220 Photoeleclric Smoke DeIec::Iors Technical Spedfic:atlons F220-B6C Four-wire Mounting Base with Auxiliary Relay Outputs AuxiIary contacIs: One set of normaIy-open (NO), common (C), normaIy closed (NC) COIilBCls Contact rating: 0.5 A at 125 VAC, 1.0 A at 30 VDC for resistive loads Power Requirements Current (alarm): 31 mA at 12 VDC, 35 mA at 24 VDC. and 40 mA maximum at 30 VDC Cunent (standby): nominaIy 90 .,... ar 12 VDC, 100 "^ at 24 VOC, and 120 "^ maximum at 32 VDC .. . I... ;. "'If01 "ill q Uv jl~~ . ,.'B"",:", "'/'"'^ ,,,~;,"~-,",,,L~~";, ,,~I+U~ll,';,:~,; . Order Number F22o-B6E ............"........'.'..'.......;>........... '"".; \'. .. ~'>-';'i~; ',.' .' -q" " ~ The F220-B6E Power Supervision Base has a normally open (NO) alarm relay and an EOL power supervision relay. The EOL relay eliminates the need for separate power supervision devices.. It is UL Listed when used in combination with the UL listed F220 detectors. Note: Use only one F22O-B6E base per zone run as the last base on the run in a style B circuit. Technical SpecifIcations F220.B6E Power SuperVISion Mounting Base Outputs AIann relay type: normaIy open (NO), '*- on alarm Relay rating: 0.5 A at 100 VDC for resistive loads Power~ Current (alarm): 25 mA at 12 VDC, 30 mA at 24 VDC, and 34 mA maximum at 30 VDC Cunent (standby): 16 mA maximum at 30 VOC EIoech SecIdy Systems For _ itfoml8lioll pIease_ -~ __1_147ll81iC1 Technical Spedfk:ations F220 Photoelectnc Smoke Detectors Detector/S- DesIgn C%r: Dimensions (diameterxD): White 6.75 in. x 2.25 in. (17.1 em x 6.4 em) EnvinInmenlal Considendlons Relative Humidity: 0Clb to 95% noncondensing (15% to 95% noncondensi'lg for CO sensing models) +32"F to + 10o-F (O"C to +38"C) Temperature (nonnaI operation): Power RequIrements Current (alarm); (detector '-I only) Current (start-up): MaDnum RMS Ripple: Powe--up Tme: Voltage (standby): 20 mA mmum ar 8.5 VDC; 35 mA maximum at 32 VDe 0.12 mA maxinum at 32 VDC 25C!b of DC input 22 ~8 maximum Two-wi'e: 8.5 VDC to 32.0 VDC Four-wire: 10.0 VOC to 30.0 VDC Trademarks Chamber Check. is a registered trademark of Bosch Security Systems in the United States. Chamber MaicfD" is a trademark of Bosch Security Systems in the United States. OeanMe. is a trademark ofGE Interlogix. BOSCH FG': 1608 Glassbreak Detector with ValueGap@ Magnetic Contact .Bass.----:o~~------ View- C~:---- ~URGLAR ALARMS ,I ,,<f( ~ Search I '~ Questions? .. ,. Click here to leave .....,1.' us a mesSdge. ~:. ~ Live chat by LivePerson Links My Account Sea rch Home Sitemap Contact Us Link To Us Returns !B Privacy !B Terms !B Shipping Policies Access Control Alarm Monitoring Anti-Theft Devices Burglar Alarm System Packages Burglar Alarm Systems CClV Video Surveillance Central Station Equipment Entertainment Systems Fiber Optics Rre Alarm Systems Garrett Metal Detectors Home Automation Intercom Systems Marine Alarms On-Q Home Other Stuff Power Supplies Sensors and Detectors !B Door & Window Sensors !B Rre & Smoke Alarms !B Gas Detectors EI Glass Break Sensors !B Moisture~ & Flood Detection !B Motion Detectors !B Optex America !B Outdoor Detectors !B Panic & HOldup Alarms Contact Us Sitemap Order Status (Choose Category] Sensors and Detectors> Glass Break Sensors Glass Break Sensors -.--" Magnetic sensors may not detect a break-in if the thief simply smashe~ window or a glass door. Our acoustic glass breakage detectors respond to actual cracking of the glass the moment someone tries to break in. The ala will sound while the thief is still outside -- not after he is already walk around inside the home. Note: While glass break sensors are an excellent enhancement to a perimeter security system, they are not a substitute for magnetic dool window sensors. The optimal design will incorporate magnetic sensors to det opening and acoustic glass detectors to detect breakage. Where possible 1 motion detectors as a backup. FG-1608 Glassbreak Detector with ValueGap@ Magnetic Contact FG-1608 Glassbreak Detector with ValueGap@ Magnetic Contact IntelliSense The fG-1608 is a combination glassbreak detector and magnetic contact that gives you t\ sensors in one for maximum versatility, performance and value. Features . FlexCoreâ„¢ Signal Processor The flexCore Signal Processor is an Application-Specific Integrated Circuit (ASIC), whi processes sound data in parallel rather than sequentially; for faster, more accura detection decisions. The combination of proven flexGuard@ performance with the speed of flexCo processing provides unmatched false alarm immunity without compromising detection. . Glassbreak Plus Forced Entry Detection Glassbreak detection is enhanced by a built-in ValueGap@ magnetic contact to monit the opening of doors and windows. The result is double protection from one sensor. . Selectable Sensitivity The sensitivity of the FG-1608 may be set to match the acoustics of the room. T\ different sensitivity levels are available; low or high. The range can then be verifi remotely with the flexGuard fG-701 Glassbreak Simulator. FG~ 1608 Glassbreak Detector with ValueGap@ Magnetic Contact ttl Photoelectric Detectors ttl Pool Alarms ~ Specialty Sensors & Detectors ~ Winland Environmental Sensors Structured Wiring Telephone Systems Wire & Catlle Proclucts by Manufacturer . Mount the Detector Anywhere The FG-1608 mounts on any wall, in the window frame, or on the ceiling, with minimum range and a maximum range of 8' (2.4 m) to the glass. . Covers All Glass Types The FG-1608 works on all glass types, including plate, tempered, laminated, wired, filr coated, and sealed insulating glass. ~ -~ . Multiple Domain Signal Analysis The FG-1608 performs Multiple Domain Signal Analysis in which time, frequency a amplitude characteristics are evaluated for signal qualification. This enables the detect to accurately discriminate false alarms from true glassbreak events. Warrantees . Two Sensors in One... ValueGap@ Contact A built-in reed switch and separate actuator magnet provide forced entry protection addition to glassbreak detection. . Indicator LED Denotes detection of sound events and alarm condition. . Alarm Memory Alarm LED can be set to latch upon alarm; helps identify which FG-1608 alarmed multiple detector applications. . Enclosed PCB The PCB is protected from potential damage during installation. . Remote Test Mode Enable and Disable Test mode can be activated remotely with the FG-701 Glassbreak Simulator. . Test Mode Time Out Automatically resets from test mode in five minutes. . Easy Installation and Set-up Mount within 8' (2.4 m) of the glass to be protected. there is no minimum range. Sele either low or high sensitivity. A TW Security Product Page page 1 ot 1 Home Site MaJ 800-8585-A TV\ ......n ... I..... - . an ..... In........ ...... Benefits & Features . Dual tone siren - steady and warble . Compact design . Indoor surface mount . Quick and easy installation Specifications Operating voltage: 6 - 14 VDC Sound output: 103 dB@ 12 VDC Current draw: 400 mA @ 12 VDC Dimensions: 4.3" x 4.3" x 2.2" Color: White Material: ASS plastic Wiring: Red-warble, Yellow-steady, B1ack- common SIRENS Hear it: Steady Warble DT-24 Dual Tone 15 Watt Surface Mount Siren For i !frilll oul cfiti'1I !Ian .... .TW'. -.... @Copyright 2004 ATW Security. All Rights Reserved 5 Cornmonweallh Avenue, Wobum MA 01801 USA Visit our other siles Mascon OEM and Mascon PCB http://www.atwbrand.com/sirensldt24.htm 2/8/2006 DTK-120S15A Series SURGE PROTECTION The DTK-120S15A &Critical Load' surge protector from DITEK is a true multi-stage series hybrid design which provides the best filtering and lowest clamp levels in its class. Available in both 120Vand 120/240V versions for circuits up to 20 Amps, it meets both government and military specs for fire panel applications. A user replaceable fuse means less down time and longer service life. FEATURES BENEFITS Series Design Fastest response time available; Tighter clamp than paralle' device Hybrid Protection Circuitry Four stages of protection insures maximum performance User replaceable fusing Less "post event" downtime Screw Lug Termination Speedy connect/disconnect of power wiring; Neat appearance, no wire nuts needed Low profile design Uses less space, fits wide variety of cabinet depths Multiple diagnostic indicators Monitor protection status, ground presence, ground fault and fuse status .';'."- .. ONE DITEK CENTER 1720 Starkey Road, largo, FL 33771 1-800-753-2345 www.ditekcorp.com General Specifications - 120S15A Agency Approvals: Ul1449, Wyle labs Service Voltage: 110-120 VAC or 120/240 VAC MCOV: 130 VAC or 130/260 VAC Continuous Current: 15 or 20 Amps (Specify) Max. Surge Current: 39,000 Amps EMIIRFI Noise Filtering: >56db 100KHz -100MHz Protection Modes: L - L. L - N. L - G. N - G Suppressed Voltage Rating: 330V Warranty: limited lifetime Warranty Diminsions: 6.00" x 3.58" x 2.32" Weight: .55 'bs. Housing: ABS .. 2X 0.19" "I ,':' . t_f ,4f. ~ fa" I · '~I IE...'_~.'. i~ i, : ,-3!i1'--i ! ;o.m"' ~.!ill' I ~r t" ..J IBI I' I8l .J ! ,. 2..94' L I~ I i -L ITI . I I 1- , I 2.32" i I . !"i15" -f ! :zx a9' i I I 1- 1 ,-::.!t. i...- --: I ~ J.:A>- -6.ocr- M-1981S15A Rev 3I23ro3 Description: Series AS Audible Strobe & Series AH Audible Appliances are id(~al for 2 wire applications with 3 selectable dBA settings (90,95, (9) and wall or ceiling mounting, wheeJock INC. Helping People Take ActionSM Strobe Options: Single Candela Wall: 1575 cd Multi Candela Field Selectable Wall: 15/30/75/110 cd or 1 35/185 cd Ceiling: 15/30/75/95 cd or 115/177 cd Features: · Selectable Continuous Horn or Temporal (Code 3) . 3 Selectable dBA settings of90, 95 and 99 dBA in both tones Series AH . Patented Universal Mounting Plate . Wall and ceiling mount Series AS · Synchronize strobe and audible with Wheelock SM DSM Sync Modules or PS-12/24-8CP ond PS-12/24-8MP Power Supplies with built-in sync protocol Specification and Ordering Information Model -- Order Strobe 24 12 Wall Ceiling Model Agency Approvals Madel Number Color Color Mounting Options# Code Candela VDC VDC Mount Mount Red White UL MEA CSFM FM BFP AS-24MCW-FR 9024 15130175/110 X X X B.D.E,F,G,H,J,N,O,R,X X X X X X AS-24MCW-FW 9025 15130175/110 X X X B.D .E,F.G,H,J ,N,O,R,X X X X X X AS-24MCWH-FR 3468 135/185 X X X B,D,E,F,G,H,J,N,O,R.X X .. X * * AS-24MCWH-FW 3469 135/185 X X X B,D.E,F,G,H,J,N.O,R.X X * X * AS-241575W-FR 7405 15 (75 on Axis) X X X B,D,E,F,G,H,J,N,O,R,X X X X X AS-121575W-FR 7410 15 (75 on Axis) X X X B.D,E,F,G,H,J.N,O,R,X X X X X AS-24MCC-FR 3161 15130175/95 X X X B,D,E,F,G,H,J,N,O,R,X X X X * * AS-24MCC-FW 3162 15/30175/95 X X X B,D,E,F,G,H,J.N,O,R,X X X X * AS-24MCCH-FW 3467 115/177 X X X B,D,E,F,G,H,J,N,O,R,X X * X * * ASWP-2475W-FR 9012 180@77"F X X X I (Outdoor) X X X X X 75@-31"F AH-24-R 7892 X X X X B,D,E,F,G,H.J,N,O,R,X X X X X X AH-24-W 7893 X X X X B,D.E.F,G,H,J,N,O,R,X X X X X X AH-12-R 7891 X X X X B,D,E.F,G,H,J,N,O,R,X X X X X X AH-12-W 7894 X X X X B.D,E,F,G,H,J,N,O,R,X X X X X X AH-24WP-R 7416 X X X X K (Outdoor) X X X * X AH-12WP-R 7415 X X X X K (Outdoor) X X X * X Average RMS Current #See mounting options pull out guide in the last section of this binder. X = Approved . = Pending Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS.241575W AS-24MCW AS-24MCWH ASWP-2475W** AS-24MCC AS-24MCCH 1575ed 15cd 30ed 75cd 110cd 135ed 185cd 15cd 30cd 75ed 95ed 115ed 177cd 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0,320 0.128 0.088 0.114 0.165 0.205 0.250 0.320 High (99) dBA ULmax" 0.080 0.121 0,088 0,125 0,200 0,267 0.355 0.480 0,168 0,095 0,138 0.221 0,285 0.355 0.480 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0,305 0,105 0.066 0.092 0.145 0.186 0.230 0.305 Med (95) dBA ULmax" 0,043 0.107 0.074 0,110 0.190 0,253 0,340 0.465 0,155 0,080 0,122 0,201 0,269 0.340 0.465 24 vdc 0.017 0.072 0,052 0.076 0.121 0.158 0.220 0.295 0.098 0.056 0.082 0.132 0.173 0.220 0.295 Low (90) dBA ULmax" 0,021 0,100 0,068 0.105 0,182 0.245 0,335 0,460 0.150 0.074 0.113 0.198 0,263 0,335 0.460 Audible Wall Mount Audible " RMS current ratings are per UL average RMS method. UL max cur AH-12 Strobe AS-121575W rating is the maximum RMS current within the listed voltage range 12 VDC Models Low Med Low 33v for 24v units). For strobes the UL max current is usually at High (99) High (99) dBA Med (95) dBA (90) dBA (95) (90) minimum listed voltage (16v for 24v units), For audibles the max cu DBA dBA DBA is usually at the maximum listed voltage (33v for 24v units), For untilt 12 \Ide 0,163 0.076 0,039 0,260 0,195 0.175 FWR ratings, see installation instructions. ULmax" 0,192 0,108 0.058 0,320 0.275 0,265 ""Audible and Visual Combined. rent (16- the rrent ered Description: Wheelock Series RSS Strobes provide a wide range of intensities and mounting options fOr wall or ceiling applications, Series RSSP Single & Multi-Candela Strobe Plates are designed fOr retrofitting existing audible notification appliances to strobe applications, Strobe Options: Single Candela: 1575 cd (wal!), 75 cd (weatherproo6 Multi Candela Field Selectable Wall: 15/30/75/110 cd or 1 35/1 85 cd Ceiling: 1 5/30/75/95 cd or 115/177 cd wheeJock INC. . Helping People Take ActionSM Features: Series RSS . Patented Universal Mounting Plate . Low current draw to reduce power consumption and wiring costs . Strobes produce 1 ftash per second over the regulated voltage range Series RSSP . Synchronize with Wheelock's SM DSM Sync Modules or PS-12/24-8CP and PS-12/24-8MP Power Supplies with built-in sync protocol Specification and Ordering Information I :odel Num~er Order Wall Ceiling Strobe 24 12 Model Model Square or Agency Approvals Color Color Mounting Optlons# I Code Mount Mount Candela VDC VDC Red White Round UL MEA CSFM FM BFP I RSS-24MCW-FR 9400 X 15/30rr5/110 X X B,D,E,F,G,H,J,N,O,P,R,X Square X X X X X - RSS-24MCW-FW 9401 X 15/30rr5/110 X X B,D,E,F,G,H,J,N,O,P,R,X Square X X X X X RSS-241575W-FR 7471 X 15 (75 on Axis) X X B,D,E,F,G,H,J,N,O,P,R,X Square X X X X X RSS-241575W-FW 7788 X 15 (75 on Axis) X X B,D ,E,F,G,H,J,N,O,P,R,X Square X X X X X RSS-121575W-FR 7476 X 15 (75 on Axis) X X B,D,E,F,G,H,J,N,Q,P,R,X Square X X X X X RSS-121575W-FW 7468 X 15 (75 on Axis) X X B ,D ,E,F,G,H,J ,N,O,P,R,X Square X X X X X RSS-24MCC-FW 3158 X 15/30rr5/95 X X B,D ,E,F,G,H,J,N,O,P,R,X Square X X X X * RSS-24MCCR-FW 3160 X 15130rr5195 X X B,D,E,F,G,H,J,N,O'p,R,X Round X X X X * RSS-24MCCH-FW 3461 X 115/177 X X B,D,E,F,G,H,J,N,O,P,R,X Square X X X * * RSS-24MCCHR-FW 3463 X 115/177 X X B,D ,E,F,G,H,J,N,O,P,R,X Round X X X * * RSS-24MCWH-FR 3465 X 135/185 X X B,D ,E,F,G,H,J,N,Q,P,R,X Square X X X * * RSSWP-2475W-FR 9013 X 180 @ 7rF X X B,D ,E,F,G,H,J ,N,O,P,R,X Square X X X X 75@-31OF RSSWP-2475W-FW 3034 X 180 @77OF X X T (Outdoor) Square X X X X * 75@-31OF RSSP-121575W-FR 7798 X 15 (75 on Axis) X X E,Z Square X X X X X RSSP-24MCW-FR 9402 X 15130rr5/110 X X E,Z Square X X X X X RSSP-241575W-FR 7793 X 15 (75 on Axis) X E,Z Square X X X X X I ~SSP-24MCWH-FR 9482 X 135/185 X X B,D,E,F,G,H,J,N,O,P,R,X Square X X X * * #See mounting options pull out guide in the last section of this binder, Average RMS Current x = Approved . = Pending RSSIRSSP RSSIRSSP - Wall Mount RSS - Ceiling Mount 24VDC 241575W 24MCW 24MCWH 24MCC 24MCCH Models 15cd 30cd 135cd 185cd 30cd 95cd 1575cd 75cd 110cd 15cd 75cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max' 0,090 0,060 0,092 0.165 0.220 0.300 0,420 0,065 0.105 0,189 0.249 0,300 0.420 RSSIRSSP RSSIRSSP . RMS current ratings are per UL average RMS method. UL max current rating is the maximum 24VDC Wall Mount RMS current within the listed voltage range (16-33v for 24v units), For strobes the UL max Models 121575W current is usually at the minimum listed voltage (16v for 24v units), For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR 12 vdc 0.152 ratings, see installation instructions, UL max' 0.255 Description: Series MT & MT Strobe Multitone Electronic Appliances are ideal for designs that require a choice of8 selectable alerting sounds for various ambient and wall conditions and 2 selectable sound output levels, wheeJock INC. ,lielpii\g People Take ActionSM Strobe Options: Single Candela: Outdoor (UL 1638): 115 VAC (UL 1638): 1 575 cd (Mn 1 80 cd (MTWP) 1 5 cd (MT4) Features: Series MT . Choice of eight (8) alerting sounds: Hom, Bell, March l1me Hom, Code- 3 Tone, Code-3 Hom, Slow Whoop, Siren, or Hi/Lo . Audible and strobe can operate trom a single NAC circuit with any of the eight Cludible sounds . MT and MTWP strobes can be Synchronized with Wheelock SM, DSM Sync Modules or PS-12/24-8CP and PS-12/24-8MP Power Supplies with built-in sync protocol Specification and Ordering Information Series MT without strobe I Agency App I Model Number Order Code Input Voltage Rated Candela Mounting Options# UL MEA CSFM MT-12124-R 5023 12124 D,E,F,L,M,O,P,R X X x I MT-12124-W 5024 12124 D,E,F,L,M,O,P,R X X x I MT-241575W-FR 8422 24 15 (75 on AXIS) D,E.F.L,M,O,P,R X X X I MT-241575W-FW 9460 24 15 (75 on AXIS) D,E,F,L.M,O,P.R X X X I MT-24MCW-FR 3301 24 15130175/110 D,E,F,L,M,O,P,R X * X [ * I MT-24MCW-FW 3303 24 15130175/110 D,E,F,L,M,O,P,R X X Mr-121575W-FR 8421 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X Ml:121575W-NW 9747 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X I MlWP-2475W-FR 8420 24 180@77"F M (Outdoor) X X X 75 @-31"F I M1WP-2475W-NW 9744 24 180 @ 77"F M (OlJdoor) X X X 75@-31'F MT4-115-R 6223 115VAC D, E, J, K, N, 0, R X X ><- - MT4- 1'5-5 6142 115VAC D, E, J, K, N, 0, R X X X MT4-115-WHNFR 6224 115VAC 15 D, E, J, K, N, 0, R X X X I MT4-12124-R 5308 12124 D, E. J, K, N, 0, R X * * ~4-1 2124-S 7997 12124 D, E, J, K, N, 0, R X * * rovals FM BFP X X X X * #See mounting options pull out guide in the last section of this binder, X = Approved . = Pending X * X X X X ~._- ._.,'-_.~-- X X X X * dBA and Current Ratings for Multitone Audible Portion ---"- n. RMS Current (amps) -,._._.~---.._-- --, 24 VDC 12VDC 120 VAC -'-'--- --- HI Output SID output HI output SID Output HIOutP~ISID ~ @ 24 VDC ULmal<" @ 24 VDC UL mal<" @ 12 VDC UL max* @ 12 VDC UL max* UL max" UL rrtax* ---,--- ~-- Hom 0.074 0.108 0.033 0,044 0,145 0.176 0,023 0,034 0,050 0.042 , -- -~ Bell 0,040 0,053 0,018 0,024 0.077 0,095 0,014 0,020 0,041 0.039 8 -. ----- -, March Time Ham 0,067 0,104 0_033 0.038 0.109 0.142 0,023 0,034 0,050 0.040 B ---.'. --- - Cod,>-3 Hom 0,069 0,091 0,026 0.Q35 0,100 0,142 0,023 0,034 0.050 0.042 B ---- -- Codl!-3 Tone 0,061 0.075 0.026 0.Q35 0,088 0,105 0_015 0,021 0,042 0,040 8 ----- -- -- Slow Whoop 0.069 0,098 0,028 0,037 0,100 0,142 0,025 0.035 0,050 I 0.042 t Siren 0,080 0,104 0,027 0_036 0.122 0,152 0,021 0,030 0,045 I 0,041 8 HVLO 0.044 0,057 0,020 0,026 0,089 0,114 0.018 0.026 0,042 i 0.039 8 CMp ---~_.. dBA@ 10ft(UL dBA@10ft dBA@ 10ft (UL Reverberant) (anechoic) Reverberant) 24 VDC 12VDC 12 and 24 VDC 120 VAC Hi SID HI SID HI SID HI SID ut Output OUput Output Output Output Output Output --, - J2 87 90 77 99 93 88 82 6 80 85 69 92 87 82 75 9 84 89 74 99 93 85 79 -- .- 8 83 88 73 99 93 85 75 ~_. .- 5 80 84 70 95 90 79 75 -- 10 89 89 75 99 94 88 82 9 84 89 75 98 i 93 85 82 6 81 86 71 93 88 82 79 ---- --- Strobe Current Ratings (AMPS) Model MT-121575 MT-241575 MlWP-2475 MT-24MCW Candela 1575cd 1575cd 180cd 15cd 30cd 75cd 110cd @24VDC 0,152 0.060 0,094 0,041 0.063 0,109 0.140 UL max' 0,255 0.090 0,138 0,060 0.092 0_165 0,220 . RMS current ratings are per UL average RMS method, UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units), For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions, 06/05 GENERAL NOTES: INSTALLATION OF MULTIPLEXED FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 1 (2003) NFPA 101 (2003) AND NFPA 72 (2002) FIRE ALARM CONTROL PANEL TO BE LOCATED AS MARKED ON PLANS. ALL STROBE cd RATINGS TO BE AS MARKED ON PLANS, IN ACCORDANCE WITH NFPA 1 (2003) NFPA 101 (2003) AND NFPA 72 (2002) INSTALLATION OF FIRE ALARM SYSTEM, WIRING, RACEWAYS, AND DEVICES WILL BE IN ACCORDANCE WITH ALL APPLICABLE NFPA CODES AND UNIFORM RULE 4A-48, RULES AND REGULATIONS OF THE STATE FIRE MARSHAL'S OFFICE, FLORIDA STATUE 633. FIRE ALARM SYSTEM INSTAL LA TION EXAM 3 or- ,,08' '- ~ ~( ~............ .n rnl ~_.~ (2\ U ~ 5/75cd I:C r~ -1A,1B,1F ,i ~B I' EXAM 2 -1A,1B -- ,-- I[~][] ~-,-~---~..- ---'- ---",,.----- -~-- --.~--~--.------ '1 rn~ '&8 '- -L) ~ EXAM 1 ~8 -fl r -1A OFFICE 15/75 15/75 15/75 .OoOmA ,OoOmA ,012mA ~ 15/75 ,OoOmA 30ed .076mA TOTAL .4 72mA 15/75 15/75 15/75 75ed 110ed 30ed 15/75 ,OoOmA .OI2mA ,012mA ,0121 mA .158mA .076mA ,OI2mA 15/75 TOTAL .0oOmA .691mA FIRE/SEC. ALARM SYSTEM RISER -~->~l-\.. , () ((;8) I r-- Ii .......... TO FIR I/SEC. .I. / PANEL 10 y /~O~D8~8 ( H,C, ~ 1" J REST RM, ~. ^ T~5/75Cd J @) ~ ~ ~= ..n ~ f~ '110 _J'1 h _. ~, 8 ~O'kO TO FIRf I/SEC. N / --PANEL rl = ( He \ REST RM. @) ~ 1o/l5cd ~ AIR HANDLER 88 & ~ AIR HANDLER [B ,~ EXAM 4 EXAM 4 10- on fO []JlEJJ 1 1A,1B,1F 1A~ ~] 1 FCPsHsFCp' I -u~ 1A,18,1F r II 1A.1JB.1 F 1-1 ~ I 1G r~ECORDS EXAM 5 EXAM 5 - I I C;v I ~C: ~ r~ "--\ 18~]1 .-::;:/' rnl n 711081 1 15/75cd ~J ~30Cd I ~ 1881 ~-- , \B ~ 0 RECEPTiONIST ~ \--I 15/75cd .!:\ EXAM 6 EXAM 6 r CJ 39 I \. ) 18 TO FIRE/SEC, PANEL t 1~ ~>-15/75Cd 0('01 0=-:"'--:;0 15/75cd -<:-1 / ~ I ~~ /-~ /- ( RE~FRM \ ~ ( ~ J@8~ J @ T-r -- -- - ~ -~ WATING AREA G8 @ UP1 [ \l~1 d LJI~ h ~~ h _ ~ ~ -.41 tr==~--L-> ~ 110ed '"== =-/1 B~ ,( T __n (: o ~r ?5: 75ed TO FIRE/SEC. PANEL GB 1\ Il~ ~ ~.lA'1B'lF- ---.. --.J -n -- ~. FIRE/SEC. ALARM SYSTEM WIRE SYMBOL A B C D E F G CIRCUIT TYPE SIGNAL LINE CIRCUIT NOTIFICATION APPLIANCE CIRCUIT CONTROL CIRCUIT BURG. WIRE BURG. WIRE ANNUNCIATOR CIRCUIT BURG. WIRE DESCRIPTION 2 - #18 AWG FPLR 2 - #16 AWG FPLR 2 - #18 AWG FPLR 4 - 22 AWG 2 - #22 AWG 4 - #18 AWG FPLR 2 - #18 AWG FIRE/SEC. ALARM SYSTEM SYMBOLS ISFCP! SECURITY /FIRE CONTROL PANEL IFCPS! FIELD CHARGER POWER SUPPLY I KEY I SECURITY/FIRE KEY PAD @ GLASS BREAK @ MOTION DETECTOR @ SMOKE DETECTOR [EJ PULL STATION ~ INDOOR SIREN [gJ<] HORN STROBE -9- STROBE LIGHT QJ JUNCTION BOX -..:l DOOR SWITCH -NVV'- END OF LINE DEVICE l EXAM 3 e :;/ EXAM 2 G~ '/ 10- ~ ~ I~ 1[881 1 GB' 7: --tkY)tJ1Cik-5> yv _ fk,. tI v<-'<'- Z!' ,;- ;MJ (/ ~ ~ @ EXAM 1 10- Building shall comply with the applicable code,s of Florida Fire Prevention Handbook NFPA & the City of Zephyrhills GB' ;/ OFFICE ~ APPROVED by Fire Marshal of Zephyrhills : CO~;V~~lall(S) @- !}~~=.n --..--.-.. - ...........~-- ---- -~ ~ INSPf~C'f10N( S )"R EQUll{ED"~~ BY ?IPH1RH-!,LLS I?- .--- !p.itlIJk~itA~7/- .~-~--_..~~,~----- ~ ~ > o cr.:: D- D- ~ W cr.:: :::) I- U W l- I U cr.:: ~ ~ ~ w if) cr.:: w W 2 C) 2 W 'l) ~~~ ~ ~ ,.. ~ ~ ~ ~ " ., ) ~ ."- '( "-1l <D o ~ cilN W 1-1- 02 2 - cr.:: C)D- 2--.J 3:~ ~I- cr.:: - 02 N ~ o N D- C) 2 3: ~ er:: o Cr:: w co co co ~ <D :::) cq u -.q- 2 f-: 2 1'0 W C) - --.J if) ~OLL 2 :>-: 6 Cr:: ~ W co- if) U I- W C) if) 2 :::) 2 2 --.J 3:--.JOcr.:: ~Ol-D- er::if)if)if) O--.J>- ~W2 if)1-~0 ZO~D- ~1-1'0cr.:: --.J LD~ D- ~ 1'0 I- U --.J ~ Z o if) if)w Wz LL~ ~--.J D-3: o w . ~>--.J o LL cr.:: ~ if)~ >-U--.J cr.::0=:! ~w:r: :r:~cr.:: C) >- .. r----.:r: co:::) 1'0 D- o~enw -::l Cl <D N 1'0 en en ~ 1 N -.q- en -----.. r----. z:~ .. 0 '-" Cr::if) W z: cr.:: 0- W --.J co co ~~OO:::?: Cr::-.q-:r:cr.:::::) ::Jow . z ~gif)if)w oZ:z:Z w w :r: 0 Cr::LLUOI LL W --.J -::l D- ~ ~ II -.q- ............ CJ (' I 1- , I l/l C -L:. ~ LL o o I ~ ~ 1E 4'1Aj, 1 rp \--IV1 T ~To-fjRf),~ fC. Kf'J .1" PANEL 1F- i I ~/75c~ ~ ~SJ > / L 1E~1 ~W~ ~1-. TO 1 ~IRE/SEC., lr [)[~ p PAN L 15/75ed \ 'lI "1~1[QQ 15/75cd K - -~ 1m ~ I J_ 1 A, 1 F !PH KEY I t.T ~J ~=~ ~ ~ cr.:: W co ~ :::) 2 I- W W :r: if) W --.J ~ U if)