HomeMy WebLinkAbout06-5591 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL ~ 5591 Permit #:5591 Issued: 3/29/2006 Permit Type: GENERAL BUILDING PERMIT Class of Work: 105-NEW CONST/MUL TI 5+ UNIT Proposed Use: TOWN HOMES Sq, Feet: Est. Value: Cost: 83,150.00 Total Fees: 7,753.69 Amount Paid: 7,753.69 Date Paid: 3/29/2006 Name: US HOME CORPORATI N Addr: 600 N WESTSHORE BLVD, STE 600 TAM PA, FL 33609 Phone: 813854-4608 Lic: Phone: Work Desc: NEW TOWNHOMES-MODEL 3-SIESTA KEY Address: MAISIE LN - 3 MODEL ZEPHYRHILLS, FL. Township: Range: Lot{s): Block: Section: Book: Page: Subdivision: EILAND PARK TOWNHOMES Parcel Number: 03-26-21-62....~D.OOOOO-0030 US HOME CO PORA TION - LENNAR MAISIE LANE - 3 MODEL ~;)'55 ZEPHYRHILLS, FL. 33542 MECHANICAL FEE WATER CONNECTION RESIDENl FIRE INSPECTION FEES PUBLIC SAFETY 5% SCHOOL IMPACT FEE 1% 73.27 RADON 419.00 WATER METER RES 3/4" 13.50 FIRE IMPACT FEE 26.35 PARK FEES TOWNHOMES 15.55 TRAFFIC IMPACT FEE 99% 1 . 16.63 180.00 273.00 769.56 1,572.12 N EE SEWER CONNECTION RESIDENl FIRE PLAN REVIEW FEES POLICE IMPACT FEE SCHOOL IMPACT FEE/100% TRAFFIC IMPACT FEE 1% 10 . 1,616.00 62.18 254.00 1,555.00 15.88 vf\~ 11Hl-0<0~ ~v ~J oG- j I DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED LINTEL PRE-METER WATER SHEATHING FRAME MISC SEWER MISC INSULATION WALL MISC MISC. MISC. INSULATION CEILING MISC. MISC. MISC. DRIVEWAY MISC. MISC. REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." ~-~ RAC ORS IGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER OWNER'S N^"E liS lIcme ~?4J,t 19-/70# - (;G- Nt1I.M:. JOB ADDRESS M.A.t~ \ e..:, f2 /).. - '(lnode' "3 LEGAL DESCRIPTION: LOT I S I I ~ I 0 BLOCK ---1- SUBOIVISION G /aJ1d IJ it ~/I/;d1l1l PARCEL 10 Jt (f)~.2~" ;1~~'M\oO-6010-CrtLl1u OUJO) (OBTAIN FROM PROPERTY,TAX NOTICE) WORK PROPSED: ~EW CONSTRUCTION 0 ADDITION DALTERATION 0 REPAIR 0 INSTALL o SIGN 0 MOVE 0 DEMOLISH PROPOSED USE: DSGL FAMILY DWELLING 'bd~~ '-'.....1....... ""- --- ----..------ BUI;LDING DEPARTMENT 5335 8rn st, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECEIVED 3/,90 loCe? PHONE CONTACT FOR PERMITTIN/<?13 )f9t? -IJ?5 X /3.:JJ PHONE 81~ - 7(/;9-5177 o Jt OF UNITS o MOBILE HOM: o COMMERCIAL o INDUSTRIAL o SWIMMING POOL o OTHER c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK -/t)Lon homt'..5 BUILDING SIZE 1&>,5'"1)( ft,3.2f'/J SQUARE FOOTAGE ~ HEIGBT ,n.?;; I RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION, ~ BUILDING ~LECTRICAL ~LUMBING Gt"'MECHANICAL o GAS ~OFING PERMITS REQUESTED $.3.10~ 8!:1 00 VAL?ATION OF TOTAL CONSTRUCTION \~() tdrttt- OIJ,r AMP SERVICE Ji( Progress Energy 0 W,R.E.C, $J ~ il.5.otJ o SPECIALTY VALUATION OF'MECHANCIAL INSTALLATION o OTHER TYPE OF CONSTRUCTION:~ BLOCK FINISHED FLOOR ELEVATIONS o FRAME o STEEL o OTHER IS PROJECT IN FLOOD ZONE AREAD YES 0 NO BUILDER ". .' / /' ..." .' STATE CERT OR REGIST * {!;j(!. /~-)/~'/~ ****************************************************************** ~ COMPANyJI3(! t!Et;fe/(1~ oJ ];;~ SIGNATURE ELECTRICIAN A4 #: SIGNATURE / . ' STATE CERT OR REGIST # ~ /1o.tJ/ ~('~ ****************************************************************** SIGNATURE COMPANyA;::..f!Ju!l. $t!A/ema,{G STATE CERT OR REGIST # c;::(! ()C// 7~ ~~********************************* :t**************** ,0 /~ COMPANY. ~ STATE CERT OR REGIST # C/J ~ 05-oylO ~.4 PLUMBER,,";::>."" SIGNAT~'y--// . 7-- cY MECHANICAL SIGNATURE COMPAN ***************************************************************** OTHER STATE CERT OR REGIST # U.S. Homes Eiland Park Town Homes Siesta Key Model 3-Maise Rd MODEL SQ. FEET PRICE MAIN OR LIVING: 1,663 $ 50.00 OTHER AREA UNDER ROOF: $ 50.00 OTHER: $ - VALUATION $ 83,150.00 FEE SHEET $ 416.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 684.00 CREDIT: $ - BUILDING LESS CREDIT: $ 684.00 ELECTRICAL: $ 104.65 PLUMBING: $ 103.00 MECHANICAL: $ 73.27 SUB-TOTAL $ 964.92 RADON: $ 16.63 TOTAL $ 981.55 SEWER: $ 1,616.00 WATER: $ 419.00 IRRIGATION: $ - TOTAL: $ 2,035.00 WATER METER:I $ IRRIGATION METER $ 180~00 I FIRE DEPARTMENT FEES PLANS TOATL: $ 62.18 INSPECTION TOTAL: $ 13.50 PERMIT TOTAL TOTAL: $ 75.68 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,825.58 I 769.56 I PARK IMPACT FEESI $ SIF'S: $ 1,555.00 100.0% $ 1,555.00 1.0% $ 15.55 TOTAL: $ 1,570.55 T1F'S: $ 1,588.00 99% $ 1,572.12 1% $ 15.88 TOTAL: $ 7,753.69 , USHOME 1 Itl/lllu (om/HIII\ May 23, 2006 City of Zephyrhills 5335 8th Street Zephyrhills, FL.33542 Re: 15BO-52-Z001 To Whom It May Concern, Please revise the following permit per the engineered letter. Thank You. Permit # 5588,5589,5591,5592,5593,5594,5595, 5596,5597 and 5598 Elizaoeth Mullins Permit Coordinator US Home Corporation Tampa City Group Purchasing 600 N. Westshore Blvd., Suite 600, Tampa, FL 33609. Telephone: 813-769-5277. Fax: 813-769-5278. www.ushometampabay.com @- -- ,-...om DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 E-mail: dengine1@danscoengineering.com CA 25948 May 10,2006 Elissa Holleran US Home Central Florida Division 600 N. Westshore Blvd., Suite 500 Tampa, FL 33609 RE: City of Zephyrhills Revisions Eiland Park 10 Unit Townhomes 15130-52-Z001, Building 1 DE # 260253 Dear Mrs. Holleran: Pursuant to your request, we have revised the plans as listed below: . All elevation trim/banding to be cut/scored, decorative finish; please refer to the attached sheets 3 and 4 for updated information. . Added off ridge vents; please refer to the attached sheets 3 and 4 for updated information. Our review is limited to the items indicated in the above-referenced project. Further, it is the client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions change from the time of our review. As always, please feel free to contact us if you have any further questions or if you should need additional information. Sincerely, DANSCO ENGINEERING, LLC ~t?~ )./Y' ThUy H. Huynh, P.E. Fla. Reg. No. 60122 Th/md H:\Clerical Files\Documents\Letters\US Home\2005 Job Files\260253- Revisions.doc FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Builder: U-s.H~ ~ Permitting Office: ~ c)h '2ep~ . Permit Number: S5Q "\ Jurisdiction Number. lo' \ lJ:>OO I FORM 600A-2004 Project Name: Address: City, State: Owner: Climate Zone: Siesta Key (P7J35 0"1~ Rd , ~\'i<-j~~~ i ~L-- US Homes Central rnoc\.e \ ~ EnergyGauge@4.0 I. New construction or existing New 2. Single family or multi-family Single family 3. Number of units, if multi-family I 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (iF) 1583 iF 7. Glass type I and area: (Label reqd. by 13-104.4.5 ifnot defuult) a. U-fuctor: Description Area (or Single or Double DEFAULT) 7a. (Sngle Defuuh) 115.0 iF b, SHGC: (or Clear or Tint DEF AUL T) 8, Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Fnune, Wood,Exterior b. Concrete, Int Insul, Exterior c, N/A d. N/A e. N/A 10. Ceiling types a, Under Attic b. N/A c, N/A II. Ducts a. Sup: Con. Ret: Con, AH: Interior b. N/A 7b. (Clear) 115.0 fP R=O.O, 288.0(p) ft R=I LO, 1184.0 fP R~4.0, 1022.0 ft2 R=19.0, 1583.0 fP Sup. R=6.0, 55.0 ft 12. Cooling systems a. Central Unit Cap: 26.0 kBtu/hr SEER: 13.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 26.0 kBtu/hr HSPF: 7.50 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 b, N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fun, PT -Programmable Thermostat, MZ-C-MuJtizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.07 Total as-built points: 16408 Total base points: 20099 PASG I hereby certify that this building, as designed, is in compliance with the Florida 7gy Code~ OWNER/AGENT: t ". DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass 0 on pages 2&4. EnergyGauge@ (Version: FLRCSB v4,O) Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Stat s, BUILDIN OF ICIAL: DATE: '7; f} -- .. FORM 600A-2004 EnergyGauge@ 4.0 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: , , , 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS Exterior Windows & Doors Exterior & Adjacent Walls SECTION 606.1.ABC.1.1 606.1.ABC,1.2.1 Floors 606.1.ABC.1.2.2 Ceilings 606.1.ABC,1.2.3 Recessed Lighting Fixtures 606.1.ABC.,1.2.4 Multi-story Houses Additional Infiltration reqts 606.1.ABC.1.2.5 606.1.ABC.1.3 REQUIREMENTS FOR EACH PRACTICE Maximum:.3 cfmlsq.ft. window area; .5 cfmlsq.ft. door area. Caulk" gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & toplbottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous inftltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration bamer is installed that is sealed to the perimeter, penetrations and seams. Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Type tC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from conditioned space, tested. Air barrier on perimeter of floor cavity between floors. Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. CHECK COMPONENTS Water Heaters SECTION 612.1 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences,) Swimming Pools & Spas 612.1 Shower heads Air Distribution Systems 612,1 610.1 HVAC Controls Insulation 607.1 604.1,602.1 REQUIREMENTS CHECK Comply with effICiency requirements in Table 612.1.ABC.3.2, Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Spas & heated pools must have covers (except solar heated). N~mercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal effICiency of 78%, Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. Separate readily accessible manual or automatic thermostat for each system. Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeâ„¢ DCA Form 600A-2Q04 EnergyGauge@lFlaRES'2Q04 FLRCSB v4.0 '..,-, ~ FORM 60oA-2004 EnergyGauge@ 4.0 WATER HEATING & CODE COMPLIANCE STATUS . Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.0 As-Built Total: 4920.0 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 11518 3662 4920 20099 6875 4613 4920 16408 I PASS I EnergyGaugeâ„¢ DCA Form 6OOA-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 <~. ~, FORM 600A-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Winter Base Points: 5836.1 Winter As-Built Points: 9498,7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 26000 btuh ,EFF(7.5) Ducts:Con(S),Con(R),lnt(AH),R6.0 9498.7 1.000 (1.000 x 1.160 x 0.92) 0.455 1.000 4613.0 5836.1 0,6274 3661.5 9498.7 1.00 1.067 0,455 1.000 4613,0 EnergyGauge 1M DCA Form 6OOA-20Q4 EnergyGauge@lFlaRES'2004 FlRCSB v4.0 -.....--- 4' . FORM 600A-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1583.0 5.86 1669.7 Single, Clear W 1.0 1.0 59.0 13.25 1.08 848.0 Single, Clear S 1.0 1.0 21.0 9.90 1.84 382.2 Single, Clear E 1.0 1.0 35.0 12.37 1.16 503.6 As-Built Total: 115.0 1733.8 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 1184.0 2.00 2368.0 Exterior 2206.0 2.00 4412.0 Concrete, 1m Insul, Exterior 4.0 1022.0 3,35 3423.7 Base Total: 2206.0 4412,0 As-Built Total: 2206.0 5791.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 42.0 7.60 3192 Exterior 42,0 5,10 2142 Base Total: 42.0 214.2 As-Built Total: 42.0 319.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 829.0 0,64 530.6 Under Attic 19.0 1583.0 0,87 X 1.00 13n.2 Base Total: 829.0 530.6 As-Built Total: 1583.0 1377 .2 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 288.O(p) -1.9 -547.2 Slab-On-Grade Edge Insulation 0.0 288.O(p 2.50 720.0 Raised 0.0 0.00 0.0 Base Total: -647.2 As-Built Total: 288.0 720.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1583.0 -0.28 -4432 1583.0 -0.28 -4432 EnergyGauge@ DCA Form 6OOA-2004 EnergyGauge@lFIaRES'2004 FlRCSB v4.0 - FORM 600A-2004 EnergyGauge@ 4.0 SUMMER CALCULATIONS . Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Summer Base Points: 26998.9 Summer As-Built Points: 25321.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (OM x DSM x AHU) (sys 1: CenlJal Unit 26000 btuh ,SEERlEFF(13.0) Oucls:Con(S),Con(R),lnt(AH),R6.O(INS) 25322 1.00 (1.00 x 1.150 x 0.90) 0.262 1.000 6874.5 26998.9 0,4266 11517.7 25321,7 1,00 1,035 0,262 1.000 6874.5 EnergyGauge TM DCA Form 6OOA-2004 EnergyGauge@lFIaRES'2004FlRCSB v4,O -,,- ~ . , FORM 600A-2004 EnergyGauge@ 4.0 SUMMER CALCULATIONS . Residential Whole Building Performance Method A - Details I ADDRESS:, , , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1583.0 25.78 7345.8 Single, Clear W 1.0 1.0 59.0 57.68 0.54 1854.1 Single, Clear S 1.0 1.0 21.0 48.22 0.57 572.9 Single, Clear E 1.0 1.0 35.0 63.97 0.53 1186.7 As-Built Total: 115.0 3613.7 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 1184.0 1.90 2249.6 Exterior 2206.0 1.90 4191.4 Concrete. lot Insul. Exterior 4.0 1022.0 1.20 1226.4 Base Total: 2206.0 4191.4 As-Built Total: 2206.0 3476.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 42.0 7.20 302.4 Exterior 42.0 4.80 201.6 Base Total: 42.0 201.6 As-Built Total: 42.0 302.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 829.0 2.13 1765.8 Under Attic 19.0 1583.0 2.82 X 1.00 4464.1 Base Total: 829.0 1765.8 As-Built Total: 1583.0 4464.1 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 288.O(p) -31.8 -9158.4 Slab-On-Grade Edge Insulation 0.0 288.O(p -31.90 -9187.2 Raised 0.0 0.00 0.0 Base Total: -9158.4 As-Built Total: 288.0 -9187.2 INFIL TRA TION Area X BSPM = Points Area X SPM = Points 1583.0 14.31 22652.7 1583.0 14.31 22652.7 EnergyGauge@ DCA Form 6OOA-2004 EnergyGauge@lFIaRES'2004 FlRCSB v4.0 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMA TED ENERGY PERFORMANCE SCORE* = 87.4 The higher the score, the more efficient the home. US Homes, . . , I. New construction or existing New 2. Single family or multi-family Single family 3. Number of units, if multi-family 1 4. Number of Bedrooms 2 5, Is this a worst case? Yes 6, Conditioned floor area (W) 1583 W 7. Glass type 1 and area: (Label reqd. by 13-104.45 unot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a. (Sngle Default) 115.0 ft, b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Gmde Edge Insulation b, N/A c. N/A 9, Wall types a. Fmme, Wood, Exterior b. Concrete, Int Insul, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic 7b. (Clear) 115.0 W R=O.O, 2&8.<l(p) ft R=ll.O, 1184.0 W R=4.0, 1022.0 ft, R=19.0, 1583.0 W b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A Sup. R""'6.0, 55,0 ft 12. Cooling systems a. Central Unit Cap: 26.0 kBtu/hr SEER: 13.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 26.0 kBtu/hr HSPF: 7.50 b, N/A c. N/A 14, Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HY AC credits (CF-Ceiling fan, CY-Cross ventilation, HF-Whole house fan, PT-Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certitY that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: CitylFL Zip: *NOTE: The homes estimated energy peiformance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP A/DOE EnergySta1f:l designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www-fsec.ucfedufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type. For actual glass type and areas, see SUJ1JII1eT & Winter Glass outpID on P.l!g,es 2&4. EnergyGauge@(Version: FLRC:sB v4.0) File name: . For: By: Job#: Wthr: Notes: RIGHT-J LOAD AND EQUIPMENT SUMMARY .11 /2 9/05 Danbury;rsr U.S. Homes Zone: Entire House Phone: A Stepping Stone P.O. Box 1795 Seffner Phone: 8 13 - 6 5 4 - 2 7 6 0 Siesta Key Fax: FL 33565 Fax: 813-759-6566 Tampa AP (S) FL WINTER DESIGN CONDmONS SUMMER DESIGN CONDmONS Outside db: 40 OF Outside db: 95 OF Inside db: 70 OF Inside db: 75 OF Design m: 30 OF Design m: 20 OF Daily Range M . ReI. Hum. : 50 % Grains Water 54 gr HEATING SUMMARY Bldg. Heat Loss Ventilation Air Vent Air Loss Design Heat Load Method Construction Quality Fireplaces Area (sq. ft.) Volume (cu.ft.) Air Changes/Hour Equivalent CFM SENSIBLE COOLING EQUIP LOAD SIZING 3 1 7 96 Btuh 23 CFM 749 Btuh 32546 Btuh Structure 20671 Btuh Ventilation 0 Btuh Design Temp. Swing 3.0 OF Use Mfg. Data n Rate/Swing Mult. 1. 00 Total Sens Equip Load 20671 Btuh INFILTRATION Simplified Average o LATENT COOLING EQUIP LOAD SIZING Internal Gains 920 Btuh Ventilation 0 Btuh Infiltration 0 Btuh Tot Latent Equip Load 920 Btuh Total Equip Load 21591 Btuh HEATING o o 1.2 o COOLING o o 0.5 o HEATING EQUIPMENT SUMMARY Make Trade Efficiency Heating Input Heating Output Heating Temp Rise Actual Heating Fan Htg Air Flow FaCtor Space Thermostat MANUAL J: 7th Ed. COOLING EQUIPMENT SUMMARY Make Trade 7.5 HSPF o Btuh o Btuh o OF 1105 CFM o . 035 CFM/Btuh Efficiency Sensible Cooling Latent Cooling Total Cooling Actual Cooling Fan Clg Air Flow Factor 12.0 EER o Btuh o Btuh o Btuh 1105 CFM o . 053 CFMlBtuh Load Sens Heat Ratio 96 Right-Suite: Ver 4. 1 . 27 SIN RSR21021 Printout certified by ACCA to meet all requirements of Manual Form J . ..",.... Danbury.rsr Job# r-:-r- MANUALJ: 7th Ed. I II Name of Room I 2 f' Running Ft Exposed Wall 3 Room Dimensi,ms, Ft. 41 Ceilngs, Ft Condit. Option TYPE OF EXPOSURE Gross Exposed Walls and Partitions 6 Windom; and Glass Doors Heating 7 Windom; and Glass Doors Cooling 8 Other doors 9 Net Exposed Walls and Partitions 10 Ceilings II Floors 12 Infiltration Siest<il Key Right-Suite if . 1 . 27 CST H1M NO. Htg Clg a 14A b 12C I: I' I f a 1C 34.6 .. r: I d e North NE/NW EJW SElSW South Horz alOE b 10E a 14A15.3 b 12C 2.7 cO.O dO.O eO.O f 0.0 a 160 1.6 b 0.0 cO.O a 22A 24.3 b 0.0 cO.O a 0.0 13 Subtot Btuh Loss=6+8.. + 11 + 12 14 Duct Btuh Loss 15 Total Btuh Loss = 13+ 14 16 17' 118 19 120 15.3 2.7 0.0 O.OJ 0.0 0.0 0.01 .. o . 0 .. 0.0 *. 0.0 ** 0.0 ** 8.7 8.7 300 4 1200 1 Area Length 8.3 2.1 0.0 0.01 0.0 0.0 31.0 0.0 89.0 0.0 0.0 0.0 6,8 6,8 8.3 2.1 0.0 0.0 0.0 0_0 2.3 0.0 0.0 0.0 0.0 0.0 0.0 Entire House 288.0 Ft 8.0 Btuh Htg CIg 1120 1184 o **** **"'* .*"'. **** "'*.. **** "''''*''' **** .... 3985 **.. ~I o "'*"'''' **** .... '~I o o o .... *.*. .... **** ***. SIN d Area Length 144 144 o o o o **** 0% 1. 00 .... RSR2102J First Floor 140.0 Ft. 0.0 x 0.0 ft 8.0 heat/cool Btuh Htg CIg 1120 o o o o o *.*. *... .*.* ...* .*.* **.. .... *.** *.*. .... 1940 .... ~ I :::: o **** o .... o ~.* 1625 o 318 o o o 183 183 8496 o o o o o o o o 3402 o o o ."'** 31796 ...* O~ 0 .... "'>II"'''' 317 9 6 .... .... 21344 .... 0% 0 .... "'*"'. 21344 **** **** 10452 .*.* o 'X: C."'.'" **.* 10452 ...* 115 o o o o o 111 .... o .."'. 4 ***. o **** o **** o **** 21 21 963 1184 o o o o 14734 3197 o o o o ."'.. , 0% 1. 00 I .... 1583 o o 288 o o 157 .... .... .... I **.* 1l05j 3454 o 318 o o o 183 183 8005 2515 o o o o 2517 o o 3692 o o 56 o o o o o 52 .*.* o .*.* 4 **.. o **."" o *.*. o ***. 21 21 1022 o o o o o 15637 o o o o o o 1200 11926 1192 ~, 6381 Printout certified by ACCA to meet all requirements of Manual J Form 6998 o o o 1200 1200 20671 o 20671 1105 o o o 140 o o 98 o 1 **.* .... .... .... I .... 7421 I .1 Area Length 144 144 -59 1184 o o o o o o o 1583 o o o o o o **** 00/1 1. 00 I .... 1 Second F10qr 148.0' Ft. 0.0 x 0.0 ft 8.0 heat/cool. Btuh Htg CIg o **** 118 4 .... o *."'. ~ I :::: o "'''''''>It 59 ~I o o o 5 9 *"''''. o **** o **** o "'."'* o **** o *"''''>11 o o 2517 CI CI 148 o o 3596 o (I 59 4 o **** **...* *... .... I .... 3631_ **** *.*. ."''** I .... .... .... 2044 () () () J .J .... .... ..*. **"'. *.*. o () -903 3197 o o CI CI o 11/29/05 1829 o o o o o o o -490 2515 o o o o 3692 o o o o o o 1200 o 8745 87 4 ~ I 4681 Length .... .*.* *... *... Area % % Ft. Btuh Htg CIg .... ***. Int. Gains: People @ Appl. @ Subtot RSH Gain=7+8..+ 12+16 Duct Btuh Gain Total RSH Gain=(1 7+ 18).PLF CFM Air Required *.*. .-.'" .... **** .... "'*"'. .... .*.. ."'.* .... *... .... .... ...* **** ...* **** **"'. .*.'" .... .... .... .... ..** .."'. *.*. .... ...* .... I .... I RIGHT-J CALCULA nON PROCEDURES A, B, C, D Job #: Siesta Key 'Zone: Entire House Procedure A - Winter Infiltration HTM Calculation* File name: 11/29/05 Danbury:rsr 1. . Winter Infiltration CFM 1 . 2 ACIHR x o Cu.Ft. x 0.0167 = o CFM 2. Winter Infiltration Btuh 1.1 x 0 CFMx 3 0 Winter TD = o Btuh 3. Winter Infiltration HIM o Btuh / 157 Total Window = and Door Area 0.0 HIM Procedure B - Summer Infiltration'HTM Calculation* 1. Summer Infiltration CFM o . 5 ACIHR x o Cu.Ft. x 0.0167 = o CFM 2. Summer Infiltration Btuh 1.1 x 0 CFM x 2 0 Summer TD = o Btuh ' 3. Summer Infiltration HIM o Btuh / 157 Total Window = and Door Area 0.0 HIM Procedure C - Latent Infiltration Gain 0.68 x 54 gr.diff. x o CFM = o Btuh Procedure D - Equipment Sizing Loads 1. Sensible Sizing Load Sensible Ventilation Load 1.1 x 0 Vent.CFM x Sensible Load for Structure (Line 19) Sum of Ventilation and Structure Loads Rating and Temperature Swing Multiplier Equipment Sizing Load - Sensible 20 Summer TD 0 Btuh + 20671 Btuh 20671 Btuh x 1. 00 RSM + 20671 Btuh 2. Latent Sizing Load Latent Ventilation Load 0.68 x 0 Vent.CFM x Internal Loads = 2 3 0 x Infiltration Load From Procedure C Equipment Sizing Load - Latent 5 4 gr.diff. 4 . No. People + + .0 Btuh 920 Btuh o Btuh 920 Btuh *Construction Quality is: a No. of Fireplaces is: o MANUALJ:. 7th Ed. Right-Suite: Ver 4. 1 .27 SIN RSR2102.1 Printout certified by ACCA tomeet all requirements of Manual Form J MANUAL J: . 7th Ed. Right-Suite: Ver 4.1.27 SIN RSR21021 RIGHT-J WINDOW DATA Job # Siesta Key , File name: Danbury.rsr . 11/29/05 . W 'S D W G L S S 0 N A S' 0 0 W C W S N K I A L 0 T H V G N .H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D' G Z L 0 X Y T M R R First Floor a n s a c n n n, y 1 90' 1.0 1.0 0.0 1.0 48.0 3 5 ..0 35.0 a n e a c n n n y 1 90 1.0 1.0 0.0 1.0 89.0 21.0 17.4 Second Floor a n s a C n n n y 1 90 1.0 1.0 0.0 1.0 48.0 24.0 24.0 a n n a c n n n y 1 90 1.0 1.0 0.0 1.0 31.0 35.0 0.0 -'.'--- # Fire Chief Robert Hartwig ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813) 780-0041 Fax (813) 780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No,: a -~ Business Name: f~, ~'L T~~Vt'\~\S BusinessAddress: ~\.\..6.\~ ~ 01 Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES ~SitePlan ~ Building Plans ~ Revision .06 sf 1J,5'cI/P STANDPIPE SYSTEM o Per Riser $25 SPRINKLER SYSTEMS 8 0 - 25 Heads $30 26 plus Heads $60 FIRE PUMP o Per Pump $100 FIRE ALARM SYSTEM 8 0 - 25 Devices $30 26 plus Devices $60 SUPPRESSION SYSTEMS ~ Wet $35 Dry $35 C02 $35 Other $35 INSPECTION FEES Annual N/C 1st Re-inspection $25 2nd Re-inspection $50 3rd Re-inspection $125 4th Re-inspection $250 5th Re-Inspection $500 Construction $15 Commercial $25 SPRINKLER SYSTEMS Hydro Undergrounds $45 Hydrostatic System $45 Wet Acceptance $30 Dry Acceptance $45 Hydrant Flow $25 Hood / Booth $30 Grease Duct $15 FIRE ALARM SYSTEM 8 System Acceptance $50 Recall Acceptance $50 OTHER Fire Wall/Smoke LP Gas Natural Gas Fuel Tanks Tent Billing Phone No.: Billing Fax No.: Contact: PERMIT FEE FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $25 5th Alarm $50 6th Alarm $75 7th Alarm $100 8th Alarm $150 9th Alarm $200 10th Alarm $250 Non Compliance $150 "Affidavit of Service/Repair" $25 $25 $15 SPRlloIKLER SYSTEMS o Automatic $15 FIRE PUMP o Fire Pump $15 FIRE ALARM SYSTEM o Detection $15 OTHER LP Gas Natural Gas Fire Works Fuel Tanks $45 $45 $25 $45 GREASENENTILATION GREASENENTILATION o Hood/Ducts $35 8 Hood/Ducts $15 ~ Kitchen Suppression $15 PLANS TOTAL ~ INSPECTION TOTA~~ PERMIT TOTAL! I Commeo~ iG~~~:}v'l~~g Li~~~~xI (11 FALSE ALARM I I TOTAL, , 7' ?~AA/ff , Date: Inspector: z!3!tJ? l~ e,,-- r 7 &r/V~// - rA- ,""\;:,:, ~ ~- (1 1'(') ~ () ("l ~ C' (~ C (') ~ (') PERFORMANCE BUSINESS PRODUCTS. INC. 813-719-aOO8 FAX 813-7111-70111 b'-'b-bS ~ CITY OF ZEPHYRHILLS ZEPHVRHILLS, FLORIDA WATER ACCT. NO, DATE 3/30/6b OWNER/ RENTER Lv5 ~ MAILING SERVICE ADDRESS (Pass SHUT OFF SERVICE 0 TURN ON SERVICE ~ INSTALL METER ~ READ METER D CHECK METER D OTHER D \'"))~ \-n - l'nod.eJ 3 - 13~ \ ~ WATER o SEWER D GARBAGE ~N CITY D OUT CITY ---1- No. OF UNIlS _ DEPOSIT AMOUNT 31,"","w~~ P.e..~- 55Q, _ AMOUNT LAST BIU _ DATE _ MISC. CHARGE WORK COMPLETED BY & DATE COMPLETED ORDER TAKEN BY '" Retain white form in office at all times. Send pink & yellow forms to Water Service Dept. Water Service Dept. to sign yellow form & return to office. 09/25/2006 12:27 FAX 813 674 0823 W~~ln"~ r~n~~lr.NU P'!~SCO COLJNTV 9' 'FLORrHA ~007/010 UMI~~ V7/~~'UO I~M~: ~U~U~ PAGE~ 1. OF 1 ISSUE OF'F:[ GE: : N RECEJ:F'T NUMBF~:: ()()9n=;489 OFFJ:C~Er. NEW F'OFi::T FUCHEY )Nn~ACT()R It:: 015:1.89 AME~_ STEVE RSMITH DDR: 15913 KING JAMES COURT /ST: ODESSA FL335565728 JRr. CHECK # ~170 CITY OF ZEPHYRHJ:LLS SOLID WASTE ~5591 ONTRACTOR~ 015189 6255 MAISIE RD LJNITU3 TOTAL AMOUNT: 13 _ 7~~ CC:NT COMPNY ACCOUNT CENTEF< AMOLJN1. DESCR:tF'TION/PERMT DATA 114 B4S0 - 363000 .w. 2 13M 73 iUt**** SOLID WASTE FEE I>R/CR 6() EC:EIVED BY ________:_..'_~_-_-------,--.~----.--.--. 09/21/2006 21:21 8139482710 IH SUN COAST HOMES PAGE 03/30 ~~~~'~~~l~11 1111111111 11I11 11'111"'1 filII 11111111 c iJ{cYnCE O:r COfMM~91C'E:M'E9{rr "cpt.: 1034111 OS: 0.00 09/19/06 ~ Ree: 10.00 IT: 0.00 --'---'___'_ Cpt)! CJe,.k Notice is hereby given that the undersigned will COmmence (recommence) to improve the following dc~cribed real property, situated in Pasco County, Florida. to-wit: sr::;c, I a) LOT# --1 JED flllT"AN PASCO COUNTYf CLfRK 0&/19/0& 11:53am 1 7065 OR BK 7186 PG Eiland Park 6255 Maisie Rd U.S. Home Corporation Central Florida Division 600 N. Westshore Blvd., Suite 600 Tampa, FL 33609 ZcohVThills. FL 33 54Q b) Said impTovements shall cemsisI of: Multi-Family R.esidence c) The name and address of tile owner of said real propeny is: d) The name and address of the contractor is: Same as above e) The namc and addTesl\ of the surety on the payment bond under Section 713,23 FS is: Not Applicablel Same as above Thc amount of such bond is $..___,__..Nlt\_____,_ f) The name and address of the person upon whom notices or other documents may be lIerved is: Not Applicable g) The name and address of the person designated in addition to the undersigned, to receiVE: a copy of the lienoTS notice as provided in Section 713.06 (2b) FS. is: h) notice. Commencement of said improvement ~haJJ be within thirty daYll from date of recording this Dated this 14th, day of SOtltember ,2006 u. Owner ~p~ ~~~ Prepared By: Kimberly Daugette US Home Corporation 600 N, WestshoTe Blvd. Suite 500 Tampa, FL 33(;09 ----..---.... ~ . Michae f ." t rnl\ Agent Who is personally known to me, Sworn lInd subscribed before me this 14 day of SeptembeT,2006 l) Notary Public: -1\.,~\tltuJ'f iliLlLL~L~ Authorized KIMBEflLY KAYDAUGETTE MY COMMISSION' DO 45&541 EXPIRES: SeplDmbar 10, 2009 ~antJII~ ".n. tlOW\, I'ut/1C U/lcll!rwrll.~ -~=~ Kimley-Horn and Associates, Inc. September 25,2006 . 5344 Ninth Street Zephyrllills, Florida 33542 Mr. Bill Burgess Building Official City of Zephyrhills 5335 8th Street Zephyrhills, Florida 33540 ~ 6~ - 5598' Sor-J~, Loca:te.cO \n 5'5W Re: Eiland Park Townhomes - Lots 1 - 10 Dear Mr. Burgess: I have reviewed the As-Built Surveys of the lot grading for the above subject lots and find them in substantial conformance with the Lot Grading Plan previously approved by the City. The project is located east of Massey Road and south of Eiland Boulevard. At this time the plat has not been recorded and addresses have not been assigned. If you have any questions, please do not hesitate to contact me at (813) 788-0400. Sincerely, KIMLEY-BORN AND ASSOCIATES, INC. ai . omelison, P.E. nior Project Manager CLC:bas Attachment cc: Lennar Homes, Inc. H:\049791 002 - Lennar Eiland Park\Lot Grade Letters - CQZ\092506 Lots l-lO.doc . TEL 813 788 0400 FAX 813 782 4978 ...... DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 E-mail: dengine1@danscoengineering.com CA 25948 October 18, 2006 Mr. Shawn Reed US Home Central Florida Division 600 N. Westshore Blvd., Suite 500 Tampa, FL 33609-1140 RE: Eiland Park 10 Unit Townhomes 15130-52-Z001, Building 1 Permit No.: 5588 to 5598 DE# 260253 Dear Mr. Reed: Pursuant to your request, we conducted a limited structural review of the above- referenced project. Specifically, we reviewed the Universal Forest Products truss layout. Our review was conducted using the Florida Building Code (2004 Edition). Please refer to the attached sheets: SK1 to SK4 for revised layouts and uplift schedule. Our review is limited to the items indicated in the above-referenced project. Further, it is the client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions change from the time of our review. As always, please feel free to contact us if you have any further questions or if you should need additional information. Sincerely, DANSCO ENGINEERING. LLC ()~; . ',All 1!.1iI,~ ll\J , In , ~mw./{;IIi-d/ , " . , Cassidy WillicH's Project Manager ~~~ Thuy H. Huynh, P.E. Fla. Reg. No. 60122 cw/thh/lm H:\Clerical Files\Documents\Letters\US Home\2006 Job Files\260253(BLDG 1) UFP layout.doc SUBJECT: US HOME, Eiland Park 10 UNIT DE#: DANSCO 15130-52-Z001, Bldg 1 260253 DE ENGINEERING, LLC Permit # 5588 to 5598 CA 25948 Designed by: Date: Checked by: Date: CW 10/18/06 SK 1/4 Problem: Engineering to revise truss layout from schematic to Universal Forest Products truss layouts. Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule, SK3 for roof framing plan and SK4 for uplift schedule, , , , , , , , ... -', , .- am - ..- a_ ~ , , ..., .., ..., .... .... .. I ... a .... ..., .... ." , .., -. I ~ . ,... am 1..- ..- ., ./ 'a' ..., 1- >0. I.... a_ J .... am 1- -- I... .- IlM:l ,to ..- -., I.no n_ , M' --a~ .... to 10 - '"" - 1,- .. " ..- t ~ -. - '11ft' i .- 1.- -- I.., '~~ - 111 It;1!'-I , I . FG211'- I "F U~]~ II FG2 L- L l . -~ -. ~ ..., - 1 ..... ... 1'- .... .... - - .... FUI ! - .JI -. dto to ., 71E IIGI ... -.. - ~... ~ .... I au - ... ~- I.... .- EM:! II. ... .- 1'- ... t E M:t I .. II. - 'La I.... ... .... - .- ~. - .. .- , - ".. fill .- I- F" I -. ~ .., - II. .... fW """ .., .- ,I I I.", -- rll-M ~ Ii I 1_. .., , I~ " II I~ -. M' ST. CROIX ST. CROIX MARTINIQUE MARTINIQUE SIESTA KEY MARTINIQUE MARTINIQUE SIESTA KEY ST. CROIX ST. CROIX FLOOR FRAMING PLAN (NTS) o SAMUEL A GREENBERG, P.E. # 34245 THUY H. HUYNH, P.E. # 60122 o IRWIN J. BENSON, P.E. # 49758 - PLFASEREFER 10 'DiE ORIGINAL SIGNID AND SEALED CO NSlRUCTION DOClJME'fIS FOR FURlHER INroRMATION NOT SHOWN -w mEBESTOFmEENGINmRS KNOWLEDGE AND BELIEF, 'DiESlRUCTIJRALPLANS AND SPI!CIFlCATIONS COMPLY WITH 'DiE FLORIDA RESIDENTIAL CODI!, SI!CTION roOI FOR 119.9 MPH 3 SI!C. GUSTEXPOSURE"B" ENCWSED WIND ZONE (2004 IDmON, INCLUDING 2005 SUPPLEMENl). . lHIS DRAWING AND DESIGN IS VALID FO R 12 MON:!!!.~ ~_'IHE.!,A1ESIG~_AND S~c__ - SIGNED AND SEALED FOR mESlRUCTIJRAL PARTOF1HIS DRAWING ONLY. ~~~L L OCT 1 8- 2006 P.O. Box 3400 Apollo Beach, Florida (813) 645-0166 Fax (813) 645-9698 . , SUBJECT: US HOME, Eiland Park 10 UNIT DE#: DANSCO 15130-52-Z001, Bldg 1 260253 DE ENGINEERING, LLC Permit # 5588 to 5598 CA 25948 Designed by: Date: Checked by: Date: CW 10/18/06 SK 2/4 Problem: Engineering to revise truss layout from schematic to Universal Forest Products truss layouts. Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule, SK3 for roof framing plan and SK4 for uplift schedule, TRUSS JOINT GRAVITY CONNECTION QTY CONN. FASTENERS'"'" -- TYPE LOCATION (LBS) CAPACITY PER CONN. 'THE FOLLOWING CONNECTIONS ARE FOR THE LEFT HAND UNITS, FOR RIGHT HAND UNITS, REVERSE :CONNECTIONS FROM LEFT TO RIGHT AND VICE VERSA - - LEFT 720 4 - 1Ed NAlLS i BM3 RIGHT 1379 HUSC410 1 1708 16-1 Dd , FRONT 448 HGUS46 1 2899 28-1Dd BM4 INTERIOR 2741 4 - 1Ed NAILS REAR 1497 WMI46 1 3380 2-10d K 1 1/2" 8. 2- 1 14" )( 1 3/4" TITEN SCREWS FG1 LEFT 905 4 - 1Ed NAILS RIGHT 574 HU210-2 1 2048 28-1Dd FG1A LEFT 888 HUC21D-2 1 2048 28- 1 Od RIGHT 825 HU21 0-2 1 2048 28-10d FG2 LEFT S86 HU21 0-2 1 2048 28-1Dd RIGHT B28 HUC210-2 1 2048 28-1Dd FG2A LEFT 926 HU21 0-2 1 2048 28-10d , RIGHT 1012 HUC210-2 1 2048 2B-1Dd f 2nd FLOOR FRAMING SIMPSON CONNEcrORS SCHEDULE i"Double connectors to placed diagonally to each other. i _ L::QQ.D.9tQr.L\'_~.I!~llsJb.!:QI:I.9ht~~lC!:!.?,~_~~i~1~_9.~.tb~P.I~P-Q?i1!'l~Q~..Q!!h.~.tr:Y~?YYhLqO_~9Yt~t.. ,force the plate off the truss. .'. : i....." Mounted verticall1'. 1! :! : ----: ,._._....._..._~._-_.__._-----_.---.--.----......"'....................--.----....--...--._...__R.__m....___._._._____:------..-m-..-.--.--.__..__..:......__...._..____.......__m..______..._..._.____.__._. 2nd FLOOR FRAMING SIMPSON CONNECTORS SCHEDULE D SAMUEL A GREENBERG, P.E. # 34245 ~ THUY H. HUYNH, P.E. # 60122 'D IRWIN J. BENSON, P.E. # 49758 . PLEASE REFER 10 "IHE 0 RIGINAL SIGNED AND SEALED CONS'lRUCTION DOCUMI!N1S FOR FURlHER INFORMATION NOT SHOWN *'10 lHEBESTOF"IHEl!NGINEERS KNOWLEDGE AND BELIEF, lHE S'lRUCnJRAL PLANS AND SPECIFlCATIONS COMPLY wrm "IHEFLORIDA RFSIDl!NTIAL CODE, SECTION IDOl FOR 119.9 MPH3 SEC. GUSTEXPOSURE"B" l!NCWSED WIND ZONE (2004 EDmON, INCLUDING 2005 SUPP * lHIS DRAWING AND DESIGN IS VALID FOR 12 ~Q~:!!!~A!'~:!!!E:.!?A~..s..!g~ ~~.!;UJiD-,-. . SIGNED AND SEALED FOR lHES'lRUCWRAL PARTOFlHIS DRAWING ONLY. ~e:,C OCT 1 B 2006 P.O. Box 3400 Apollo Beach, Florida (813) 645-0166 Fax (813) 645-9698 SUBJECT: US HOME, Eiland Park 10 UNIT DE#: DANSCO 15130-52-2001, Sldg 1 260253 DE ENGINEERING, LLC Permit # 5588 to 5598 CA 25948 Designed by: Date: Checked by: Date: CW 10/18/06 SK 3/4 Problem: Engineering to revise truss layout from schematic to Universal Forest Products truss layouts, Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule, SK3 for roof framing plan and SK4 for uplift schedule, II II II ..., W W, II II ~ ~~ I I I I, 1 ~ I 1 I I I I '. "- I I 51< 1 . \. ... , . , . -.. / l- '\. I ~1~ I / I- "- I I I I I </< / I '<1< I I / 40- "- I ~I~ I , .~ - ~ "- I I I I / -- '\.1 I I I IJ I / I , , , , , 1 1"\ / I I / I I I -~ ! ! '"\ I ~ - - - . !'\ . - - - - - - I I L I I ~D" I I, I I I / I ==..i\ ,":..=.i\ I ~ 1/ / I "- ;' I l'~""" '\ ' u;:'- ~ , "- ,..., I " I / f\ / f'\ I ~ ;- " 1 V , (, ~f'\ I I / I" It ~ ~ 1 / " V - " '\. , '\ , . 11>< K I / " - ti / .. GI - I . 1 21/ II~ !1m I ,:p , .~-p R1 ~ II\.. /11 I !!~...J L ...- ST. CROIX MARTINIQUE MARTINIQUE SIESTA KEY MARTINIQUE MARTINIQUE SIESTA KEY ST. CROIX ST. CROIX ST. CROIX ROOF FRAMING PLAN (NTS) D SAMUEL A GREENBERG, P.E. # 34245 -j?!1 THUY H. HUYNH, P.E. # 60122 (D IRWIN J. BENSON, P.E. # 49758 . PLEASERE1<ER TO 'IHE ORIGINAL SIGNID AND SFALEO CONS lRUCTIO N DOCUMliN1S FOR FURIHER INFORMATION NOT SHOWN '10 1HEBESTOF'IHEl!NGINEERS KNOWLEDGE AND BELIEF, lHESlRUCWRAL PLANS AND SPE'ClFICATIONS COMPLY wrm 'IHEFLORIDA ~f ?(.,L RESIDl!NTIALCOD:r, SE'CTION R301 FOR 119.9 MPH 3 SE'C. GUST EXPOSURE "B" l!NCWSED WIND WNE(2004 EDmON,lNCUJDING 2005 SUPPLEMEN'I). OCT r 8 2006 . 'IHlS DRAWING AND DESIGN IS VALID FO R 12 MQ~!HS_~~._~.P~~~!c:;_~~.s~-,__, . SIGNED AND SFALEO FOR 'IHESlRUClURAL PARTOF'IHIS DRAWING ONLY. P.O. Box 3400 Apollo Beach, Florida (813) 645-0166 Fax (813) 645-9698 SUBJECT: US HOME, Eiland Park 10 UNIT DE#: DANSCO 15130-52-Z001, Bldg 1 260253 DE ENGINEERING, LLC Permit # 5588 to 5598 CA 25948 Designed by: Date: Checked by: Date: - CW 10/18/06 SK 4/4 Problem: Engineering to revise truss layout from schematic to Universal Forest Products truss layouts, Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule, SK3 for roof framing plan and SK4 for uplift schedule, iUPLlFT SCHEDULE UPLIFT VALUES SHOWN ARE CALCULATED BASED ON CONSERVATIVE APPROACH AND CAN BE DIFFERENT FROM TRUSS MANUFACTURER'S VALUES TRUSS JOINT UPLIFT CONNECTION QTY CONN. FASTENERS- .__m...._..____.__._.. --___h_ ---0...-----.-- .----........-------.....-.-.__......_ __.....__....... ____.___..__.__ -.---........--.----.-.....__...._......_m...__... TYPE LOCATION (LBS) CAPACITY PER CONN. iTHE FOLLOWING CONNECTIONS A.RE FOR THE LEFT HAND UNITS, FOR RIGHT HAND UNITS, REVERSE iCDNNECTIONS FROM LEFT TO RIGHT AND VICE VERSA G1 FRONT 1206 HTS20 1 1450 24-1Od x 1112" REAR 1134 HHETA20 1 2235 1O-10d x 1 112' LEFT 2975 MGT (I) 1 3140 22-10d x 1112" &518" EMBED, INTO SIMPSON SET EPOXY RIGHT 2975 USP KLEG HANGER (SEE DETAIL NS2.2 ON ORIGINAL S&S FOR UPLIFT CONNECTION) E2A , !NOTE: ALL OTHER TRUSS BRG. CONNECTIONS ARE SIMPSON HHETA20 FOR JMASONRY; SIMPSON H10 FOR FRAME: & HUS26 FOR HUNG TRUSSES ON GIRDERS ! UNLESS OTHER WISE NOTED, ........---.........-.....______m._....______._____._......._.._____.__......_.____._..._.___.._____.....___________................._.._.._..__..._..._.._ fTHESETRUSS UPLIFT VALUES ARE LESS THAN CONNECTION CAPACITY ! MASONRY HHETA20 2235 10-10d x 1 112" . TIMBER H1D 850 16-Bd x 1 112" D SAMUEL A GREENBERG, P.E. # 34245 8' THUY H. HUYNH, P.E. # 60122 D IRWIN J. BENSON, P.E. # 49758 'PLEASE~ 10 'IHEORIGINALSIGNm AND SEALm CONSlRUCTION DOCUMENlS FOR FURlHER INFORMATION NOTSHOWN '10 'IHEBESTOFlHEENGINEF.RS KNOWLEDGE AND BELIEF, mE SlRUCTIJRAL PLANS AND SPECIFICATIONS COMPLY WrIH TIlEFLORIDA RESIDI!'N1IAL CODE:, SECTION roOt FOR 119.9 MPH 3 SEC, GUSTEXPOSURE "B" ENCWSED WIND WNE(Z004 EDmON, INCLUDING ZOOS SUPPLEMEN'I}. , TIllS DRAWING AND DESIGN IS VALID FOR 1Z ~Q}'I_~~-~:!!IE~A~_l'.!~~_~~~. , SIGNED AND SEALED FOR mESlRUCTIJRAL PARTOFTIlIS DRAWING ONLY. HUNG HUS26 1 1317 20-10d L~.Q9_LJ~~_~_on~f!~~JO RI@-q~fLdJ~gonf!UyJ.~~.@.fh_91f:!?Ij.,_.____,__L__.__________..__..._______..1 l~~~~~:~--== ~T:"~!-"t==~=':c====~ 'T..... Mounted vertically, . f ! ,(1) Connection at the exterior wall; ,; , ---'----------------------------.---OPLl Ff--SCHEOULE-----.---------------. REFER TO ORIGINAL S&S FOR INFO. NOT SHOWN -!J~fL oct 1.81 2006 P.O. Box 3400 Apollo Beach, Florida (813) 645-0166 Fax (813) 645-9698