HomeMy WebLinkAbout06-5592
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
/
5592
Permit #: 5592 Issued: 3/29/2006
Permit Type: GENERAL BUILDING PERMIT
Class of Work: 1 05-NEW CONST/MUL TI 5+ UNIT
Proposed Use: TOWNHOMES
Sq, Feet: Est. Value:
Cost: 83,150.00 Total Fees:
Amount Paid: 7,756.14 Date Paid:
Address: MAl IE LN - 4 MODEL
ZEPHYRHILLS, FL.
Township: Range:
Lot{s): Block: Section:
Book: Page:
Subdivision: EILAND PARK TOWNHOMES
Parcel Number: 03-26-21-oz.zo-oo000-0040
MECHANICAL FEE
WATER CONNECTION RESIDENl
FIRE INSPECTION FEES
PUBLIC SAFETY 5%
SCHOOL IMPACT FEE 1%
6 .
73.27 RADON
419.00 WATER METER RES 3/4"
13.50 FIRE IMPACT FEE
26.35 PARK FEES TOWNHOMES
15.55 TRAFFIC IMPACT FEE 99%
N
16.63 SEWER CONNECTION RESIDENl
180.00 FIRE PLAN REVIEW FEES
273.00 POLICE IMPACT FEE
769.56 SCHOOL IMPACT FEE/100%
1,572.12 TRAFFIC IMPACT FEE 1%
1,616.00
62.18
254.00
1,555.00
15.88
~Y';lX!Cp
l2w~~ IO/~
~f)-+ U
()v
R
DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB
DUCTS INSULATED LINTEL PRE-METER WATER
SHEATHING FRAME MISC SEWER
MISC INSULATION WALL MISC MISC.
MISC. INSULATION CEILING MISC. MISC.
MISC. DRIVEWAY MISC. MISC.
REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)( c) when extra inspection
trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
. ~~
SIG ATURE PERMIT OFFI
LL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
./
'-'..&..1"'"'... ......... --- ----"'------
~UIiLDING DEPARTMENT 5335 8ra at, Zephyrhills, FL 33542
813-780-0020 FAX: 813-780-0021 DATE RECEIVED 3l~y.o lo~;.
PHONE CONTACT FOR PERHITTIN'~/3 )f91J - /JJ?5
. - X/3~1
OWNER'S NAME tiS lime ~LPJ()Jt/ft7tJAJ - tGAJ;1/.~ PHONE 8'~ -'7&9-5177
MA.i~ \ e:, {(;J.. ~od~ \ y.
LEGAL DESCRIPTION: LOT(S) 1"'10 BLOCK--L- SUBDIVISIONtilOJ1dIJrlc. 7f}p)/}/;{}1T/(
PARCEL ID it (!)~'2~.. $~~~.()()\oO.6010 (rue) elOO) (OBTAIN FROM PROPERTY.TAX NOTICE)
WORK PROPSED: i)4TEW CONSTRUCTION 0 ADDITION o ALTERATION 0 REPAIR 0 INSTALL
DSIGN 0 MOVE 0 DEMOLISH
PROPOSED USE: DSGL FAMILY DWELLING 'W~~
JOB ADDRESS
Oft OF UNITS
o MOBILE HOM:
o COMMERCIAL
o INDUSTRIAL
o SWIMMING POOL
o OTHER
c:J RESTAURANT & HEALTH DEPARTMENT AP~ROVAL
DESCRIPTION OF WORK -jC)LUJ1 h0I11t'..5
BUILDING SIZE I ~.!'"I)( ft,3:zf'/j SQUARE FOOTAGE ~ HEIGHT ,n.?;; I
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS,
IF SIGN PERM~T ONLY (2) SETS OF ENGINEERED PLANS REQUIRED,
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION,
'~ BUILDING
~LECTRICAL
~LUM8ING
r;(MECHANICAL
o GAS ~OFING
PERMITS REQUESTED
$.3....W~ 81:/ 00 VAL~ATION OF TOTAL CONSTRUCTION
\ {"Q Mrt.. tJlJI r AMP SERVICE ~ Progress Energy 0
W.R.E.C.
$J ~ il.5:ot)
o SPECIALTY
VALUATION OF'MECHANCIAL INSTALLATION
o OTHER
TYPE OF CONSTRUCTION:~ BLOCK
FINISHED FLOOR ELEVATIONS
o FRAME
o STEEL
o OTHER
IS PROJECT IN FLOOD ZONE AREAD YES 0 NO
BUILDER
SIGNATURE
/." .' ... STATE CERT OR REGIST * {!,6(. /d.)/'I'I~
****************************************************************** ~
COMPANyJI3~ [?Eef;e;(1~ oj la/l7fK<-
'"
/"
/
ELECTRICIAN ~ ~
SIGNATURE /. - . .
STATE CERT OR REGIST # ~ /'jO~/ ~f1h
******************************************************************
::=~~ :::::N:~:~~~~IS~~r:~702/
********************************* *~**************** ~
MECHANICAL COMPANY ~
SIGNATURE STATE CERT OR REGIST # tit e. 05uY/O
SIGNATURE
********************************************~****~***************
OTHER
u.s. Homes
Eiland Park Town Homes
Martinque Model 4 - Maise Rd MODEL
SQ. FEET PRICE
MAIN OR LIVING: 1,663 $ 50.00
OTHER AREA UNDER ROOF: $ 50.00
OTHER: $ -
VALUATION $ 83,150.00
FEE SHEET $ 416.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 684.00
CREDIT: $ -
BUILDING LESS CREDIT: $ 684.00
ELECTRICAL: $ 107.10
PLUMBING: $ 103.00
MECHANICAL: $ 73.27
SUB-TOTAL $ 967.37
RADON: $ 16.63
TOTAL $ 984.00
SEWER: $ 1,616.00
WATER: $ 419.00
IRRIGATION: $ -
TOTAL: $ 2,035.00
WATER METER:I $
IRRIGATION METER $
180~00 I
FIRE DEPARTMENT FEES
PLANS TOA TL: $ 62.18
INSPECTION TOTAL: $ 13.50
PERMIT TOTAL
TOTAL: $ 75.68
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $
3,828.03 ,
769.56 ~
PARK IMPACT FEES I $
SIF'S: $ 1,555.00
100.0% $ 1,555.00
1.0% $ 15.55
TOTAL: $ 1,570.55
TlF'S: $ 1,588.00
99% $ 1,572.12
1% $ 15.88
TOTAL: $
7,756.14 I
USHOME
~ I f,/I/ill (Olll/Jilt/\
May 23, 2006
City of Zephyrhills
5335 8th Street
Zephyrhills, FL.33542
Re: 15130-52-Z001
To Whom It May Concern,
Please revise the following permit per the engineered letter.
Thank You.
Permit # 5588,5589,5591,5592,5593,5594,5595,5596,5597 and 5598
Elizaoeth Mullins
Permit Coordinator
US Home Corporation
Tampa City Group Purchasing
600 N. Westshore Blvd., Suite 600, Tampa, FL 33609 . Telephone: 813-769-5277. Fax: 813-769-5278- www.ushometampabay.com
~
........-
,-
DE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
E-mail: dengine1@danscoengineering.com
CA 25948
May 10,2006
Elissa Holleran
US Home Central Florida Division
600 N. Westshore Blvd., Suite 500
Tampa, FL 33609
RE: City of Zephyrhills Revisions
Eiland Park 10 Unit Townhomes
15130-52-Z001, Building 1
DE # 260253
Dear Mrs. Holleran:
Pursuant to your request, we have revised the plans as listed below:
. All elevation trim/banding to be cut/scored, decorative finish; please refer to the attached
sheets 3 and 4 for updated information.
. Added off ridge vents; please refer to the attached sheets 3 and 4 for updated
information.
Our review is limited to the items indicated in the above-referenced project. Further, it is the
client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions change
from the time of our review.
As always, please feel free to contact us if you have any further questions or if you should
need additional information.
Sincerely,
DANSCO ENGINEERING, LLC
~ I'/~
).~
TI1UY H. Huynh, P.E.
Fla. Reg. No. 60122
Th/md
H:\Clerical Files\Documents\Letters\US Home\2005 Job Files\260253- Revisions.doc
FORM 600A-2004
EnergyGauge@ 4.0
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
US1531M- MARTINIQUE -1531 S.F. L1VINGAREABuilder: u.s. HOMES
LP2.53 m~ (20. - yiY"'\O(~ ~ Perm~tting Offic.e: Qtt~-Lc..h Y-f~
, "2<_p~h.G_L_!) ~l...-- Permit Number. S5~
lA S -\-\:~ Jurisdiction Number: Loll wc>'0
Central
Project Name:
Address:
City, State:
Owner:
Climate Zone:
New construction or existing New
Single family or multi-family Multi-family
Number of units, if multi-family 4
Number of Bedrooms 2
Is this a worst case? Yes
Conditioned floor area (fF) 1531 ft2
Glass type 1 and area: (Label reqd. by 13-104.4.5 ifnot default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2
b. SHGC:
(or Clear or Tint DEFAULT)
8. Floor types
a. Slab-On-Grade Edge Insulation
b. Raised Wood, Post or Pier
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft
b. N/A
1.
2.
3.
4.
5.
6.
7.
7b.
(Clear) 127.0 ft2
R=O.O, 134.0(p) ft
R=1l.0,124.0ft2
R=4.1, 789.0 ft2
R=4.1, 1400.0 ft2
R=19.0, 878.0 ft2
12. Cooling systems
a. Central Unit
Cap: 28.0 kBtulhr
SEER: 12.00
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 30.0 kBtulhr
HSPF: 7.80
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 40.0 gallonS
EF: 0.92
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fan,
PT-Programrnable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone beating)
Glass/Floor Area: 0.08
PASS
Total as-builtpoints: 17404
Total base points: 20751
I hereby certify that the plans and specifications covered by
this calculation are in campI" ce the Florid nergy
Code.
PREPARED BY:
DATE: /r- 2-2.. -
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
comPliance, with Section 553.908~
Florida Statutes. .
BUILDING 0 CI: . tJ
DATE:
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output 0
EnergyGauge@ (Version: FLRCSB v4.0)
FORM 600A-2004
EnergyGauge@4.0
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
US1531M- MARTINIQUE -1531 S.F. LIVING AREABuilder: U.s. HOMES
Permitting Office:
Permit Number:
Jurisdiction Number.
Project Name:
Address:
City, State:
Owner:
Climate Zone:
Central
l
!
I
1. New construction or existing New
2. Single family or multi-family Multi-family
3. Number of un,its, if multi-family 4
4. Number of Bedrooms 2
5. Is this a worst case? Yes
6. Conditioned floor area (ft') 1531 ft,
7. Glass type I and area: (Label reqd. by 13-104.4.5 ifnot default)
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft,
b. SHGC:
(or Clear or Tint D EF A UL T)
8. Floor types
a. Slab-Dn-Grade Edge Insulation
b. Raised Wood, Post or Pier
c. N/A
9. Wall types
a. Concrete, lnt Insul, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft
b. N/A
7b.
(Clear) 127.0 ft,
R=O.O, 134.0(p) ft
R= 11.0, 124.0ft'
R=4.1, 789.0 ft,
R=4.1, 1400.0 ft,
R=19.0, 878.0 ft'
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(lfR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF- Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Cap: 28.0 kBtulhr
SEER: 12.00
Cap: 30.0 kBtu/hr
HSPF: 7.80
Cap: 40.0 gallons
EF: 0.92
Glass/Floor Area: 0.08
Total as-builtpoints: 17404
Total base points: 20751
PASS~
I hereby certify that the plans and specifications covered by
this calculation are in compl" ce the Florid nergy
Code.
PREPARED BY:
DATE: //- 2--2- -
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge@ (Version: FLRCSB v4.0)
I
FORM 600A-2004
EnergyGauge@ 4.0
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , .
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points
.18 1531.0 25.78 7104.5 Single, Clear W 1.3 6.0 16.0 57.68 0.94 863.8
Single, Clear W 6.0 4.0 7.0 57.68 0.46 187.6
Single, Clear E 6.0 9.0 40.0 63.97 0.64 1642.1
"
Single, Clear W 1.3 6.0 16.0 57.68 0.94 863.8
Single, Clear W 1.3 10.0 16.0 57.68 0.99 912.3
Single, Clear E 1.3 6.0 32.0 63.97 0.94 1917.7
As-Built Total: 127.0 6387.2
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 1400.0 0.70 980.0 Concrete, Intlnsul, Exterior 4.1 789.0 1.18 931.0
Exterior 789.0 1.90 1499.1 Concrete, Intlnsul, Adjacent 4.1 1400.0 0.65 903.0
Base Total: 2189.0 2479.1 As-Built Total: 2189.0 1834.0
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.20 144.0
Exterior 20.0 4.80 96.0
Base Total: 20.0 96.0 As-Built Total: 20.0 144.0
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 878.0 2.13 1870.1 Under Attic 19.0 878.0 2.82 X 1.00 2476.0
Base Total: 878.0 1870.1 As-Built Total: 878.0 2476.0
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
.
Slab 134.0(p) -31.8 -4261.2 Slab-On-Grade Edge Insulation 0.0 134.0(p -31.90 -4274.6
Raised 124.0 -3.43 -425.3 Raised Wood, Post or Pier 11.0 124.0 1.83 226.3
Base Total: -4686.5 As-Built Total: 258.0 -4048.3
INFIL TRA TION Area X BSPM = Points Area X SPM = Points
1531 .0 14.31 21908.6 1531.0 14.31 21908.6
EnergyGauge@ DCA Form 600A-2004
EnergyGauge@/FlaRES'2004 FLRCSB v4.0
FORM 600A-2004
EnergyGauge@ 4.0
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUlL T
Summer Base Points: 28771.8 Summer As-Built Points: 28701.5
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (OM x DSM x AHU)
(sys 1: Central Unit 28000 tituh ,SEERlEFF(12.0) Ducts:Unc(S),Con(R),lnt(AH),R6.0(INS)
28702 1.00 (1.08x 1.150 x 0.85) 0.284 1.000 8652.9
28771.8 0.4266 12274.0 28701.5 1.00 1.061 0.284 1.000 8652.9
r-
EnergyGauge 1M DCA Form 600A-2004
.EnergyGauge@/FlaRES'2004 FLRCSB v4.0
'''',-.-\..,.
..,..",
FO~M 600A-2004
EnergyGauge@ 4.0
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUlL T
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point
.18 1531.0 5.86 1614.9 Single, Clear W 1.3 6.0 16.0 13.25 1.01 213.6
Single, Clear W 6.0 4.0 7.0 13.25 1.10 102.2
Single, Clear E 6.0 9.0 40.0 12.37 1.10 542.9
Single, Clear W 1.3 6.0 16.0 13.25 1.01 213.6
Single, Clear W 1.3 10.0 16.0 13.25 1.00 211.9
Single, Clear E 1.3 6.0 32.0 12.37 1.01 401.6
As-Built Total: . 127.0 1685;8
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 1400.0 1.80 2520.0 Concrete, Int Insul, Exterior 4.1 789.0 3.31 2607.6
Exterior 789.0 2.00 1578.0 Concrete, Int Insul, Adjacent 4.1 1400.0 2.08 2912.0
Base Total: 2189.0 4098.0 As-Built Total: 2189.0 5519.6
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
-.
Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.60 152.0
Exterior 20.0 5.10 102.0
Base Total: 20.0 102.0 As-Built Total: 20.0 152.0
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 878.0 0.64 561.9 Under Attic 19.0 878.0 0.87 X 1.00 763.9
Base Total: 878.0 561.9 As-Built Total: 878.0 763.9
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 134.0(p) -1.9 -254.6 Slab-On-Grade Edge Insulation 0.0 134.0(p 2.50 335.0
Raised 124.0 -0.20 -24.8 Raised Wood, Post or Pier 11.0 124.0 0.47 58.4
Base Total: -279.4 As-Built Total: 258.0 393.4
INFIL TRA TION Area X BWPM = Points Area X WPM = Points
1531.0 -0.28 -428.7 1531.0 -0.28 -428.7
EnergyGauge@ DCA Form 600A-2004
EnergyGauge@/FlaRES'2004 FLRCSB v4.0
...-.,..~
. "~.."
FORM 600A-2004
EnergyGauge@ 4.0
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUlL T
.
Winter Base Points: 5668.7 Winter As-Built Points: 8086.0
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (OM x DSM x AHU)
(sys 1: Electric Heat Pump 30000 btuh ,EFF(7.8) Ducts:Unc(S),Con(R),lnt(AH),R6.0
8086.0 1.000 (1.068 x 1.160 x 0.87) 0.438 1.000 3831.0
5668.7 0.6274 3556.6 8086.0 1.00 1.083 0.438 1.000 3831.0
EnergyGauge ™ DCA Form 600A-2004
EnergyGauge@/FlaRES'2004 FLRCSB v4.0
..',"'"
.-,.(..,-".
FORM 600A-2004
EnergyGauge@4.0
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , ,
PERMIT #:
BASE AS-BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.0
As-Built Total: 4920.0
CODE COMPLIANCE STATUS
BASE AS-BUlL T
Cooling, + Heating + Hot Water = Total Cooling + Heating. + Hot Water = Total
Points Points Points Points Points Points Points Points
12274 3557 4920 20751 8653 3831 4920 17404
I
PASS
I
EnergyGauge TM DCA Form 600A-2004
EnergyGauge@/FlaRES'2004 FLRCSB v4.0
FORM 600A-2004
EnergyGauge@4.0
Code Compliance Checklist
Residential Whole Building p.erformance Method A - Details
I ADDRESS: , , ,
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
Exterior Windows & Doors
Exterior & Adjacent Walls
SECTION
606.1.ABC.1.1
606.1.ABC.1.2.1
Floors
606.1.ABC.1.2.2
Ceilings
606.1.ABC.1.2.3
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Multi-story Houses
Additional Infiltration reqts
606.1.ABC.1.2.5
606.1.ABC.1.3
PERMIT #:
REQUIREMENTS FOR EACH PRACTICE CHECK
Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area.
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Air barrier on perimeter of floor cavity between floors.
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
COMPONENTS
Water Heaters
SECTION
612.1
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
Swimming Pools & Spas
612.1
Shower heads
Air Distribution Systems
612.1
610.1
HVAC Controls
Insulation
607.1
604.1, 602.1
REQUIREMENTS CHECK
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required.
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
Separate readily accessible manual or automatic thermostat for each system.
Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGauge TM DCA Form 600A-2004
EnergyGauge<ID/FlaRES'2004 FLRCSB v4.0
..
RIGHT -J SHORT FORM
Entire House
SIMPSON MECHANICAL
Job: MARTINIQUE -1531 S.F.
LIVING AREA 11/22/2005
12302 N. NEBRASKA AVE., TAMPA, FL. 33612 Phone: (813)558-0858 Fax: (813)558-8578
Project Information
For: U.S. HOMES
Design Information
Htg
Outside db (OF) 40
Inside db (OF) 70
Design TD (OF) 30
Daily range
Inside humidity (%)
Moisture difference (gr/lb)
Clg
95
75
20
M
50
47
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
o
HEATING EQUIPMENT
Make Carrier
Trade WeatherMate 38EYG
38EYG03030/31
COOLING EQUIPMENT
Efficiency
Heating input
Heating output
Heating temperature rise
Actual heating fan
Heating air flow factor
Space thermostat
7.8 HSPF
30000
27
1000
0.042
Btuh @ 4rF
of
cfm
cfm/Btuh
Make Carrier
Trade WeatherMate 38EYG
38EYG03030/31
FX4BNF030 - 5 K.W.
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual cooling fan
Cooling air flow factor
12.0 SEER
22300
5700
28000
1000
0.051
Btuh
Btuh
Btuh
cfm
cfm/Btuh
Load sensible heat ratio 80 %
Area Htg load Clg load Htg A VF ClgAVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
68 3578 1869 150 96
100 1566 2199 66 113
160 1052 908 44 46
131 823 194 35 10
297 7038 4895 296 251
102 444 411 19 21
239 4172 3890 175 199
58 206 207 9 11
146 674 942 28 48
58 206 207 9 11
174 4030 3811 169 195
ROOM NAME
FOYER
KITCHEN - NOOK
DINING
POWDER - STAIRS
LIVING
STAIRS - HALL
MASTER S.R.
MASTER SA TH
FLEX ROOM
HALL SA TH
B.R. # 2
Bold/itallc values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
~ vvrlghtsoft Right-Suite ResidenlialTM 5.0.60 RSR29818
ACCr-.. \\Simpsonfileservlshareddocs\Tommy\My Documents\Wrightsoft HVAC\US1531 M.rsr
2005-Nov-22 12:36:32
Page 1
. _.~.,.'3'CI
..."':."
Erftire House dl 1531 I 23788 19534 1000 I 1000
Ventilation air 0 0
Equip. @ 1.00 RSM 19534
Latent cooling 5020
TOTALS 1531 23788 24554 1000 1000
BolcI/Jtalic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
;S:. \Nrlght~c>ft Right-Su~e Residenlial™ 5.0.60 RSR29818
~ \\Simpsonfileservlshareddocs\TommylMy Documents\Wrighlsoft HVAC\US1531 M.rsr
2005-Nov-22 12:36:32
Page 2
. r~~.. \.-...
....oL.:
~ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 86.5
The higher the score, the more efficient the home.
1. New construction or existing New
2. Single family or multi-family Multi-family
3. Number of units, if multi-family 4
4. Number of Bedrooms 2
5. Is this a worst case? Yes
6. Conditioned floor area (fF) 1531 ft2
7. Glass type1 and area: (Label reqd. by 13-104.4.5 ifnot default)
a. V-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2
b. SHGC:
(or Clear or Tint DEFAULT)
8. Floor types
a. Slab-On-Grade Edge Insulation
b. Raised Wood, Post or Pier
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft
b. N/A
7b.
(Clear) 127.0 ft2
R=O.O, 134.0(p) ft
R=11.0, 124.0ft2
R=4.I, 789.0 ft2
R=4.1, 1400.0 ft2
R=19.0, 878.0 ft2
12. Cooling systems
a. Central Unit
Cap: 28.0 kBtulhr
SEER: 12.00
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
Cap: 30.0 kBtulhr
HSPF: 7.80
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 40.0 gallons
EF: 0.92
b. N/A
c. Conservation credits
(HR.-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV-Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has ~omplied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before fmal inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLAlRES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP A/DOE EnergyStar1Mdesignation),
your home may qualifY for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see th,e Energy Gauge web site at www.fsec.ucfedufor
information and a list of certified Raters. For information about Florida's EnergyEfficiency Code For Building
Construction, contact the Department of Community Affairs at 850/487-1824.
I Predominant glass type. For actual glass type and are~ see Summer & Winter Glass oiJtput on...mtges 2&4.
r.nergyGauge@ (Version: FLRCSH v4.0)
'-"'..~
,..J,....
..
> .
Fire Chief Robert Hartwig
ZEPHYRHILLS FIRE DEPARTMENT
6907 Dairy Road, Zephyrhills, FL 33542
Bus (813) 780-0041 Fax (813) 780-0044
FIRE SERVICE USER FEES
Occupancy No.:
Plan No.: a -~
Business Name: f~, ~"- ~\-x\'l'l~S
BusinessAddress: ~\.6..\~ ~ DJ
Business Phone No.:
Business Fax No.:
Contact:
PLAN REVIEW FEES
~SitePlan ~
Building Plans ~
Revision .06 sf
/(S'z4b
STANDPIPE SYSTEM
o Per Riser $25
SPRINKLER SYSTEMS
8 0 - 25 Heads $30
26 plus Heads $60
FIRE PUMP
o Per Pump $100
FIRE ALARM SYSTEM
B 0 - 25 Devices $30
26 plus Devices $60
SUPPRESSION SYSTEMS
~ Wet $35
. Dry $35
C02 $35
Other $35
INSPECTION FEES
Annual N/C
1 st Re-inspection $25
2nd Re-inspection $50
3rd Re-inspection $125
4th Re-inspection $250
5th Re-Inspection $500
Construction $15
Commercial $25
SPRINKLER SYSTEMS
Hydro Undergrounds $45
Hydrostatic System $45
Wet Acceptance $30
Dry Acceptance $45
Hydrant Flow $25
Hood / Booth $30
Grease Duct $15
FIRE ALARM SYSTEM
B System Acceptance $50
Recall Acceptance $50
OTHER
Fire Wall/Smoke
LP Gas
Natural Gas
Fuel Tanks
Tent
Billing Phone No.:
Billing Fax No.:
Contact:
PERMIT FEE
FALSE ALARM FEE
1 st Alarm N/C
2nd Alarm N/C
3rd Alarm N/C
4th Alarm $25
5th Alarm $50
6th Alarm $75
7th Alarm $100
8th Alarm $150
9th Alarm $200
10th Alarm $250
Non Compliance $150
"Affidavit of Service/Repair"
$25
$25
$15
SPRIWKLER SYSTEMS
o Automatic $15
FIRE PUMP
o Fire Pump $15
FIRE ALARM SYSTEM
o Detection $15
OTHER
LP Gas
Natural Gas
Fire Works
Fuel Tanks
$45
$45
$25
$45
GREASENENTILATION GREASENENTILATION
o HoodlDucts $35 8 Hood/Ducts $15
~ Kitchen Suppression $15
PLANS TOTAL ~ INSPECTION TOTA~~ PERMIT TOTAL! I
~,~.~C:- 13 Sc!
Commeo', ,G ~&h,~0~~~ .l~~~k..r /71
FALSE ALARM I I
TOTAL. .
7' ?e.P<-A/5
r
Date:
Inspector:
z/3/&?
'1f~7
~,v~1/
r~
o
()
~
o
('\
o
('\
o
o
('\
(1
o
PERFORMANCE BUSINESS PRODUCTS. INC. 813-719-8008 FAX 813-719-7919
CITY OF ZEPHYRHILLS
ZEPHYRHILLS, FLORIDA
Jo- 06S 3
WATER ACCT. NO.
DATE
3/30Jo~
,
OWNER/
RENTER
lk-S
.\--\ CrY-n.I2-
MAILING
~-
~
SERVICE ADDRESS to~53 ~l^~O
SHUT OFF SERVICE 0
..\';.,,, ~ TURN ON SERVICE 9""
INSTALL METER @"'"
READ METER 0
CHECK METER 0
OTHER 0
l-n - tncrt-e1 4 - 16ld~ \
19'" WATER
o SEWER
o GARBAGE
/id" IN CITY
o OUT CITY
--1- No. OF UNITS
_ DEPOSIT AMOUNT
3/4" W~ ~
P.e\" rn..a:- - 5 sg ~
_ AMOUNT LAST BILL
_ DATE
_ MISC. CHARGE
WORK COMPLETED BY
& DATE COMPLETED
ORDER TAKEN BY
Retain white form in office at all times.
Send pink & yellow forms to Water Service Dept.
Water Service Dept. to sign yellow form & return to office.
.J
08/25/2008 12:27 FAX 813 874 0823
CENTRAL. PE.'F"~M:rtTINEr''..,
PABCO COUNTY., F'-r61b.ri~
~004/010
DATE~ 09/22/06 TIME:: :I.0r.:t.7
'PAGEe: j. OF :L
ISSUE: OFFICE::. N
.- RI::CtlPT NUfl'lHR:: 00973~:jt2
OFFICE:: NEW PORT FUCHI::;V
lNTRACTOR #= 015189
~ME :: STEVE R ~)M 1: TH
)DR:: 159j.;.:': 1:::r.NG ,TAMES COURT
/ST :: ODES~IA FL 335545728
'R~ CHECK
CITY OF ZEPHYI~Hr.LLS
Sf.lLID WASTE #5592
:ITRACTClR:: 015:J.i:J9 6253 MAISIE RD UNITtt4
TOT AlM AMOUNT: 13.,"13
:NT COMF'NY Ar:CO~NT C:l::NTER AMOLlNT .
. 4 B450 - 36:.'''X)OO - 2 1,3.. -73
.. 5 :1.:70
DESCRIPF~ON/PERMT DATA
tt****')f SOl.:. iD WASTE' FEE:
DR/CF~
60
.,'
"
.;~ r VEl> BY
. - P\.~.. , ' :
..._-----------~....._-._---_:.....__......__.. .
,.
...:
09/21/2006 21:21
d)
8139482710
IH SUNCOAST HOMES
PAGE 04/30
111111I11111 II//lIIII' ""III1l1 1IIII 1111I11111111" mlllll
2006190759
r
Rcpt: 1034111
DS: 0.00
09/19/06
Rec: 10.00
IT: 0.00
_...__.._.___ Dpty Clerk
..
9{OTICE O:F COMM'E?{CEM'E9(r
~
Notice is hereby given that thc unden;igned will COmmcnce (recommence) to
improve the following described real property, situated in Pasco
County, Florida, to-wit:
155012
a)
JED PItT"AN1 PASCO COUNTY CLERK
09/19/06 1 :538'" I of 1
OR BK 7186 PG 766
LOT# --1
Eiland Park
~53 Maisie Rd
~~!; ~ ~
;:;~'" >- ~
zo[l ~ (,.)
g~ir1 ~ 5
~~~~
~ge:~~II~
... 0 r:r:
!;( :J: ""..... _
c( 0 :r.::~,:%:,....l
O "'0"'" 0<1;
()~>-2W
a:CI)~~c;~
o ~ ffic..:>a: 0<1;
...J c..:>t;8
u. u.. Oww .0::
u..O~~?:~
O -0-
>-Cf.)t,:l::ic
UJI-.:i:c~:Z
I-Z""'~a..
....:::l .....
....0 "-'02
~Q ~~ ~ ~
Zeohvrhills. FL 335~Q
b)
Said improvements shall consist of: Multi-Family Residence
c)
The name and address of the owncr of said real pl"opetty is:
U.S. Home Corporation Central Florida Division
600 N. Westshore Blvd., Suite 600
Tampa, FL 33609
The name and address of the contractor is:
Same as above
e) The name and address of the surety on (he payment bond undeT Section 713.23 FS is:
Not Applicablel Same as above
The am(lunt of such bond i$ $ N/A
.t) The name and address of the person upon whom notices or other documents may be served is:
g)
h)
notice.
Not Applicable
The name and address of the person designated in addition to the undersigned, 10 receive a copy of
the Hcnors notice as provided in Section 713.06 (2b) FS. is;
Commencement of said im1,'lrovement shall be within thirty days from date of recording this
Dated this 14th
Prepared By: Kimberly Daugclte
US Home Corporation
600 N. Westshore Blvd.
Suite 500
Tampa, FL 33609
fI1;::..
, .....
'. ~
day of ---.S_e.p.tm!~!'__, 2006
Owner
l Authorized
Michael K. ~ Agent
Who is personally known to me,
Sworn and subscribed before me this 14 day of
September.2006 j ) r
1\ [ '. ~ ~.
Notary Public: (... llll . Lu.D{ L!lV-( lr1fi
!~.~~.."..
.1t~I'!f,t:.
t~~J
'".,p.:..r.\\'~
KlhABERL Y KAY DAUGeTrE
MV COMMISSION' DO 458541
EXPIRES: SeplEfllber 10. 2009
!lantlcod TII'" NOIlllyPe v.~_w~",
~=~
Kimley-Horn
and Associates, Inc.
September 25, 2006
.
5344 Ninth Street
Zephyrhills, Florida
33542
Mr. Bill Burgess
Building Official
City of Zephyrhills
5335 8th Street
Zephyrhills, Florida 33540
~ 6~ - 5598"
So f-J ~ Loc-a::iQ.cO
1(') ~
Re: Eiland Park Townhomes - Lots 1- 10
Dear Mr. Burgess:
I have reviewed the As-Built Surveys of the lot grading for the above subject lots
and find them in substantial conformance with the Lot Grading Plan previously
approved by the City.
The project is located east of Massey Road and south of Eiland Boulevard. At
this time the plat has not been recorded and addresses have not been assigned.
If you have any questions, please do not hesitate to contact me at (813) 788-0400.
Sincerely,
KIMLEY-HORN AND ASSOCIATES, INC.
ai . omelison, P .E.
nior Project Manager
CLC:bas
Attachment
cc: Lennar Homes, Inc.
H:\049791002 - Lennar Eiland Park\Lot Grade Letters - COZ\092506 Lots l-lO.doc
.
TEL 813 788 0400
FAX 813 782 4978
DE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
E-mail: dengine1@danscoengineering.com
CA 25948
October 18, 2006
Mr. Shawn Reed
US Home Central Florida Division
600 N. Westshore Blvd., Suite 500
Tampa, FL 33609-1140
RE: Eiland Park 10 Unit Townhomes
15130-52-Z001, Building 1
Permit No.: 5588 to 5598
DE# 260253
Dear Mr. Reed:
Pursuant to your request, we conducted a limited structural review of the above-
referenced project. Specifically, we reviewed the Universal Forest Products truss
layout.
Our review was conducted using the Florida Building Code (2004 Edition). Please refer
to the attached sheets: SK1 to SK4 for revised layouts and uplift schedule.
Our review is limited to the items indicated in the above-referenced project. Further, it is
the client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions
change from the time of our review.
As always, please feel free to contact us if you have any further questions or if you
should need additional information.
Sincerely,
DANSCO ENGINEERING, LLC
~~
Cassidy Williar,s
Project Manager
~t(~
Thuy H. Huynh, P.E.
Fla. Reg. No. 60122
cw/thh/lm
H:\Clerical Files\Documents\Letters\US Home\2006 Job Files\260253(BLDG 1) UFP layout.doc
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130.52-Z001, Bldg 1 260253
DE ENGINEERING, LLC Permit # 5588 to 5598
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 1/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
.., ! , , i_ , , , I.... , , ..,
-, , , T ... : .~ I- i ..- ,.... ". , , , ..,
-, : ,. ."
,." I .... .." ... , ". ..,
... I ... , ..,
I .. ..,
~. .... -~ -- ".
....
T .... -~ .- n. IlM:I
-...;tl:l .... - ., , .-
.., Q!: tl:l ~ ..~
.... -~ 1.- i-T'"'''_ "'t-"- r- I !E
_u 1.- -~ ". .-
-- '.Iflll' FC2A TI:2A -
~1IIiIf:::::: t!- '-11"- FG
~~~ I
. FG211~ I '~F~RIIIFG2]~ II
~ '1.:... ...
... ..., I!:ii ..... ~
IU' - , ..... I'" T
.... - i - ..... .UI ! ! - .1 ..
n1tl:l -- tl:l
.." .... -
-.;I ,IE ,.... .- ..... !E
,~" .... , "'" .... I"" .....
, L....I!IlM3 r- ... .... .... ... 'LaT Il~ oj,
.-- >1M PIa ,... I'\IIJ .....
~ .... FWII .... .... ...
! ... ...
... , .... .... F" .- F.. I , ..
... .., ,- ... PIa FUI FCII ~ -,
.., I , 1..- -. -- .... ~ I I .
. ! !...
... II III I I ..
, ,
ST. CROIX
ST. CROIX
MARTThUQm MARTIMQm
SIESTA KEY MARTINIQm MARTINIQm SIESTA KEY ST. CROIX
ST. CROIX
FLOOR FRAMING PLAN
(NTS)
o SAMUELA GREENBERG, P.E. #34245
THUY H. HUYNH, P.E. # 60122
o IRWIN J. BENSON, P.E. # 49758
"PLEASEREFER'lO lHEORIGINALSIGNED AND
SFALED CONSlRUCTION DOClJMEIl1S FOR
FURlHER INFO RMATION NOTSHOWN
"10 lHEBESTOFlHEI!NGINEERS KNOWLEDGE
AND BELIEF, lHE SlRUClURAL PLANS AND
SPECIF1CATIONS COMPLY wrm lHEFLORIDA
RESIDI!N1IAL CODE, SECTION R30I FOR 119.9
MPH 3 SEC. GUSTIiXPOSURE "B" ENCLOSED
WIND ZONE(2004 EDmON, INCLUDING 2005
SUPPLEMl!:Nl).
" 1HIS DRAWING AND DESIGN IS VALID FOR 12
~ON:!!!~_A~_1HE.!>A~ SIG!!~LAND SFALED.__
"SIGNED AND SEALED FOR 1HESlRUClURAL
PARTOF1HIS DRAWING ONLY.
~~~L C-
OCT 1 f 2006
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813) 645-9698
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130-52-2001, Bldg 1 260253
DE ENGINEERING, LLC Permit # 5588 to 5598
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 2/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
.,
TRUSS JOINT GRAVITY CONNECTION QTY CONN. FASTENERS-
-
TYPE LOCA TJON (LBS) CAPACITY PER CONN.
THE FOLLOWING CONNECTIONS ARE FOR THE LEFT HAND UNITS. FOR RIGHT HAND UNITS, REVERSE
:CONNECTIONS FROM LEFT TO RIGHT AND VICE VERSA
BM3 LEFT 720 4 - 161:1 NAILS
- RIGHT 1379 HUSC410 1 1708 15-10d
FRONT 448 HGU845 1 2899 28-101:1
BM4 INTERIOR 2741 4 - 18d NAILS
REAR 1497 WMI46 1 3380 2-10d x 1 112" & 2- 1/4" x 1 3/4"
TlTEN SCREWS
:
, FG1 LEFT 905 4 - 161:1 NAILS
RIGHT 574 HU210-2 1 2048 28-10d
FG1A LEFT 888 HUC210-2 1 2048 28- 10d
RIGHT 825 HU210-2 1 2048 28-1 Dd
FG2 LEFT 986 HU21D-2 1 2048 28-1 Dd
RIGHT B28 HUC210-2 1 2048 28- 10d
FG2A LEFT 926 HU21D-2 1 2048 28-lOd
RIGHT 1012 HUC21D-2 1 2048 28-lOd
, , , i
2nd FLOOR FRAMING SIMPSON CONNECTORS SCHEDULE
-----..-
"'Double connectors to placed diagonally to each other. ! _
!~~gQ._QQt_Qr.:!Y~I!~llS.-'D.cQ~.9ht~~.rr':!S..~J?l~~.Q'ltQ~QgQQ?!!~?19.~.qf.!b~_.!r_L!??.If.Y!!if.b~9L!J~L..
Lorce the plate off the truss _ ,- '. -
:........ Mounted vertic;all\/. I I . I :
,.-..-.....-.....-----...---..---.---.._._L_......"'~.__.__.-.--~._...._-...____..___._......_....__.----'---____--'_.~_._._~.......m...._....___._.:_._....._..___......~.____________
2nd FLOOR FRAMING SIMPSON CONNECTORS SCHEDULE
D SAMUEL A GREENBERG, P.E. # 34245
THUY H. HUYNH, P.E. # 60122
<D IRWIN J. BENSON, P.E. # 49758
. PLFASEREl'ER m lHEORIGINAL SIGNED AND
SFALED CONSlRUCTION DOCVMI!N'IS FUR
FURlHER INFORMATION NOT SHOWN
.10 lHEBESTOFlHEENGINFmS KNOWLEDGE
AND BELIEF, lHE SlRUCllJRAL PLANS AND
SPB::IFlCATIONS COMPLY WITH lHEFLORIDA
RESIDE'lTIAL CODE, SECTION roOI FUR 119.9
MPH 3 SB::. GUST EXPO SVRE "B" E'lCLOSED
WIND ZONE (2004 EDmON, INCLUDING 2005
SUPP
. lHlS DRAWING AND DESIGN IS VALID FU R 12
~Q~!I!S ~.~Q~~_~.!9~~ SFALED.:..__
. SIGNED AND SEALED FUR 'llIESlRUCTIJRAL
PARTOFlHIS DRAWING ONLY.
!jf ~_ L-
ocr 1 B 2006
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813) 645-9698
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130-52-Z001, Bldg 1 260253
DE ENGINEERING, LLC Permit # 5588 to 5598
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 3/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
R R ..n. r 11
, ~ I I I I I l~ l
I , , I , I):=-- i
I I <!< I
~._.. , , , , , ~.. /
i-- " I I ~l~ I I 7" I-
" I I , , <1< 7
I '</< I 7
.I- "" I !:l'Ej , , r.: ~ -
J...I "I I / w...
" I I I ,/
I I I
'" , , , , / ,
I " I I /
, :,...v "- I
-~ I I ! I
~ - - - , , , "- - - -
,
/' I , , , '"
/ P I I ,
, ==~ , ;r~.., , , ""
-;; }., I I~''''' ~ oAr='W&IT ~, ""
, ,
.,...., 1/ "- I 1/ I -
oF " ,/ ill "- 7 ..;;;
, I I
" I f Il 7"
" 17
I-- / " 1\ /, -
., 7 .. 1 Gl B~ /
.
r ~ .~ 1 ,rr IT Iii :::t1 ~ i
, 71~ f1-lI- '
/11
!~.:Tf ....... r
."H.
ST. CROIX MARTINIQUE MARTINIQUE
SIESTA KEY MARTINlQUE MARTINIQUE SIESTA KEY ST. CROIX
ST. CROIX ST. CROIX
ROOF FRAMING PLAN
(NTS)
o SAMUEL A GREENBERG, P.E. # 34245
''if!:} THUY H. HUYNH, P.E. # 60122
(0 IRWIN J. BENSON, P.E. # 49758
. PLEASE~ TO TIlE ORIGINAL SIGNFll AND
SEAUD CONSlRUCTIONDOCUM>>rn; FOR
FURtHER INFORMATION NOTSHOWN
.ID 1HEBESTOFTIlEENGINEERs KNOWLEDGE
AND BELIEF, 1HESlRUCTIlRALPLANS AND
SPECIFICATIONS COMPLY WITII TIlE FLORIDA ~gzL
RESIDENlIALCODE, SECTION R301 FOR 119.9
MPH 3 SEC. GUST EXPO SURE "B" ENCLOSED
WIND ZONE (2004 EDmON, INCLUDING 2005
SUPPLEMFN1). OCT 1~ 8 2006
. 1HIS DRAWING AND DESIGN IS VALID FOR 12
M~TIlS~~_~.Q.~!J:!:~!~~~p.s~"__
. SIGNED AND SFALED FOR mESlRUClURAL
PARTOF1HIS DRAWING ONLY.
P.o. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813) 645-9698
SUBJECT: US HOME, Eiland Park 10 UNrT DE#:
DANSCO 15130-52-2001, Bldg 1 260253
DE ENGINEERING, LLC Permit # 5588 to 5598
CA 25948 Designed by: Date: Checked by: Date:
- CW 10/18/06 SK 4/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
: UPLIFT SCHEDULE
UPLIFT VALUES SHOWN ARE CALCULATED BASED ON CONSERVATIVE APPROACH AND CAN BE
DIFFERENT FROM TRUSS MANUFACTURER'S VALUES
TRUSS JOINT UPLIFT CONNECTION QTfI CONN. FASTENERS-
-.-......-...-.--.--.- --------.-- ...---...---.-- .-.---......----.-.----.--....-........ --..--..--- ------- -.-.--......--..------..----...--....-....--........--...
TfPE LOCATION (LBS) CAPACITY PER CONN.
THE FOLLOWING CONNECTIONS ,ARE FOR THE LEFT HAND UNITS. FOR RIGHT HAND UNITS, REVERSE
!CONNECTIONS FROM LEFT TO RIGHT AND VICE VERSA
~-.. -- -N_ ~"'__.'.'A-__~__
E2A
FRONT
REAR
1206
1134
HTS20
HHETA20
1450
2235
24-1Dd x 1112"
1Q-1Od x 1 112"
1 3140 22-10dx1112"&51B"EMBED.
INTO SIMPSON SET EPOXY
USP KLEG HANGER (SEE DETAIL A1S2.2 ON ORIGINAL S&S FOR
UPLIFT CONNECTION)
T
!NOTE: ALL OTHER TRUSS BRG. CONNECTIONS ARE SIMPSON HHETA20 FOR
I MASONRY; SIMPSON H10 FOR FRAME; &. HUS26 FOR HUNG TRUSSES ON GIRDERS
)lJH~~~~_.QIfiER V\nSE !'JQIs12:-____.._________________________________.._________..._
'THESETRUSS UPLIFT VALUES ARE LESS THAN CONNECTION CAPACITY
LEFT
2975
MGT(I)
G1
RIGHT
2975
: MASONRY
HHETA2D
2235
1O-1Dd x 1 112"
TIMBER
H10
850
16-Bd x 1 112"
D SAMUEL A GREENBERG, P.E. # 34245
i!9> THUY H. HUYNH, P.E. # 60122
D IRWIN J. BENSON, P.E. # 49758
" PLFASE REliER 10 'DIE ORIGINAL SIGNED AND
SEALED CO NSlRUCno N DOCl1MENlS FOR
FURlHlR INFO RMAno N NOT SHOWN
"10 'DIEBFSTOFTIlEENGINEImS KNOWLEDGE
AND BELIEF, 'DIESlRUClURALPLANS AND
SPECIFlCAnONS COMPLY WIlH TIlEFLORlDA
RFSIDENllAL CODE, SECnON RJO] FOR 119.9
MPH 3 SEC. GUSTEKPOSURE"B" ENCLOSED
WIND WNE(2004 EDmON, INCLUDING 2005
SuPPLEMENl).
"TIlIS DRAWING AND DESIGN IS VALID FOR 12
~9.}'I}!!S_~ 'DIEl!,'I,~.,!!.!~~ ~ S~~
" SIGNED AND SEALED FOR "UlESlRUClURAL
PARTOFTIlIS DRAWING ONLY.
HUNG HUS26 1 1317 20-10d
LQ9y.Q~~Qn~-~torsJQp..I'!~~ctgjElgonaUyJQ_~~fb._9th~L_1._._______________________._____.
fr~~~~~~=_=_~=J==r~~=r=if=,~_=__===!
!..tt Mounted vertically. ., . i .
,(1) Connection at the exterior wall- _ i ,
----.-.-----------.-.-------------UPLIFT-SC"HEOUCE----.-..--------..-.---.
REFER TO ORIGINAL S&S FOR INFO. NOT SHOWN
~jJ K,L
OCr 1.8 2006
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166