Loading...
HomeMy WebLinkAbout06-5598 " CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 5598 Permit #:5598 Issued: 3/29/2006 Permit Type: GENERAL BUILDING PERMIT Class of Work: 1 05-NEW CONST/MUL TI 5+ UNIT Proposed Use: TOWNHOMES Sq. Feet: Est. Value: Cost: 69,600.00 Total Fees: 7,661.93 Amount Paid: 7,661.93 Date Paid: 3/29/2006 Name: US HOME RATION Addr: 600 N WESTSHORE BLVD. STE 600 TAMPA. FL 33609 Phone: 813854-4608 Lic: Phone: Work Desc: NEW TOWNHOMES-MODEL 10-ST CROIX Address: MAISIE LN - 10 MODEL ZEPHYRHILLS. FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: EILAND PARK TOWNHOMES Parcel Number: 03-26-21-5555-00100-0100 US HOME CORPORATION - LENNAR MAISIE LANE -10 MODEL ZEPHYRHILLS, FL. 33542 IL IN F E MECHANICAL FEE WATER CONNECTION RESIDENl FIRE INSPECTION FEES PUBLIC SAFETY 5% SCHOOL IMPACT FEE 1 % 69.27 RADON 419.00 WATER METER RES 3/4" 13.50 FIRE IMPACT FEE 26.35 PARK FEES TOWNHOMES 15.55 TRAFFIC IMPACT FEE 99% 13.92 SEWER CONNECTION RESIDENl 180.00 FIRE PLAN REVIEW FEES 273.00 POLICE IMPACT FEE 769.56 SCHOOL IMPACT FEE/100% 1,572.12 TRAFFIC IMPACT FEE 1% 1,616.00 62.18 254.00 1,555.00 15.88 ~-D'/ ~,cp J ,,~C) ~ J ~JL I Dfl;U~ rt F T R U DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED LINTEL PRE-METER WATER SHEATHING FRAME MISC SEWER MISC INSULATION WALL MISC MISC. MISC. INSULATION CEILING MISC. MISC. MISC. DRIVEWAY MISC. MISC. REINSPECllON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)( c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording ice of commencement." - ~. C ORS IGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOnCE REQUIRED PROTECT CARD FROM WEATHER '-'.&oj...... .....,- --- ----------- BUliLDING DEPARTMENT 5335 8TH at, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECEIVED 3/,90 IC)fL~ PHoNE CONTACT FOR PERMITTIN/<f13 )~qtJ -IYf'5 . - X/3JI OWNER'S NAME tI.f' !/:me ~.t'...AJJt/917tJ/ll- t6N;I~ PHONE 81~ -7ft/l-j)77 JOB ADDRESS ftl4i~ \ e.. 12 ().. Dnod.e \ \ 0 . LEGAL DESCRI PTION : LOT I S I I ~ I 0 BLOCK -L SUBDIVI SION h/and IJ it 7flu;11/Jd1l1t PARCEL 10 # (I)~.212.:.2l" $~$~'OO\oO.60}O (rue) 01(0) (OBTAIN FROM PROPERTY.TAX NOTICE) WORK PROPSED: ~EW CONSTRUCTION 0 ADDITION o ALTERATION 0 REPAIR 0 INSTALL o SIGN 0 MOVE 0 DEMOLISH PROPOSED USE: OSGL FAMILY DWELLING 'bd~~~ 0# OF UNITS o MOBILE HOM: o COMMERCIAL o INDUSTRIAL o SWIMMING POOL o OTHER c:J RESTAURANT & HEALTH DEPARTMENT APpROVAL DESCRIPTION OF WORK -/ c)lV/'J hom ~ 5 BUILDING SIZE , ~.S 'fA))( ftJ3:2f'/.J SQUARE FOOTAGE J 5" ~W0 ( RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERM~T ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. HEIGHT ~-7S I 9Q BUILDING ~LECTR1CAL ~LUMBING uf'MECHANI CAL o GAS ~OFING PERMITS REQUESTED $.310~ 8K'! 00 VAL?ATION OF TOTAL CONSTRUCTION l~O t*t.. OIJ,r AMP SERVICE ~ Progress Energy 0 W.R.E.C. $-' ~ il.5. 06 o SPECIALTY VALUATION OF'MECHANCIAL INSTALLATION o OTHER TYPE OF CONSTRUCTION:~ BLOCK FINISHED FLOOR ELEVATIONS o FRAME o STEEL o OTHER IS PROJECT IN FLOOD ZONE AREAO YES 0 NO BUILDER COMPANY SIGNATURE , / ..' STATE CERT OR REGIST * (!.rJ(. 1,;;.:)/,/'/4.- I ****************************************************************** ~ COMPANyJ 13~ EI ct;-/;eI(7~ ()!];i~ / ELECTRICIAN k ~ SIGNATURE / .'. ' STATE CERT OR REGIST # ~ j10b/ ~~h ****************************************************************** OTHER COMPANY A,eiIJuR. 01!A/ e mO-.fG STATE CERT OR REG1ST # er:e. ()c..j/7:2/ ********************************* *t**************** .~o , ~ ..., " PLUMBER.....' SIGNA TU~e:.. .' /,/' /..' Q;/'" MECHANICAL COMPANY STATE CERT OR REG1ST # C/J (!. 05ty-/IO ********************************************~****~*************** U.S. Homes Eiland Park Town Homes St. Croix Model 1 O-Maise MODEL Back SQ. FEET PRICE MAIN OR LIVING: 1,392 $ 50.00 OTHER AREA UNDER ROOF: $ 50.00 OTHER: $ - VALUATION $ 69,600.00 FEE SHEET $ 360.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 600.00 CREDIT: $ - BUILDING LESS CREDIT: $ 600.00 ELECTRICAL: $ 103.60 PLUMBING: $ 103.00 MECHANICAL: $ 69.27 SUB-TOTAL $ 875.87 RADON: $ 13.92 TOTAL $ 889.79 SEWER: $ 1,616.00 WATER: $ 419.00 IRRIGATION: $ - TOTAL: $ 2,035.00 WATER METER:I $ IRRIGATION METER $ 180~00 I FIRE DEPARTMENT FEES PLANS TOA TL: $ 62.18 INSPECTION TOTAL: $ 13.50 PERMIT TOTAL TOTAL: $ 75.68 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,733.82 1 769.56 ~ PARK IMPACT FEESI $ SIF'S: $ 1,555.00 100.0% $ 1,555.00 1.0% $ 15.55 TOTAL: $ 1,570.55 TIF'S: $ 1,588.00 99% $ 1,572.12 1% $ 15.88 TOTAL: $ 7,661.931 US HOME" ,\ lUII/(/I CWll{111Il\ May 23, 2006 City of Zephyrhills 5335 8th Street Zephyrhills, FL.33542 Re: I5130-52-Z00l To Whom It May Concern, Please revise the following permit per the engineered letter. Thank You. Permit # 5588, 5589, 5591, 5592, 5593,5594,5595,5596,5597 and 5598 Elizaoeth Mullins Permit Coordinator US Home Corporation Tampa City Group Purchasing 600 N. Westshore Blvd., Suite 600, Tampa, FL 33609 . Telephone: 813-769-5277 . Fax: 813-769-5278. www.ushometampabay.com @- -..... ,........... DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 E-mail: dengine1@danscoengineering.com CA 25948 May 10, 2006 Elissa Holleran US Home Central Florida Division 600 N. Westshore Blvd., Suite 500 Tampa, FL 33609 RE: City of Zephyrhills Revisions Eiland Park 10 Unit Townhomes 15130-52-Z001, Building 1 DE # 260253 Dear Mrs. Holleran: Pursuant to your request, we have revised the plans as listed below: . All elevation trim/banding to be cut/scored, decorative finish; please refer to the attached sheets 3 and 4 for updated information. . Added off ridge vents; please refer to the attached sheets 3 and 4 for updated information. Our review is limited to the items indicated in the above-referenced project. Further, it is the client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions change from the time of our review. As always, please feel free to contact us if you have any further questions or if you should need additional information. Sincerely, DANSCO ENGINEERING, LLC ~t'/~ )./Y' Tnuy H. Huynh, P.E. Fla. Reg. No. 60122 Th/md H:\Clerical Files\Documents\Letters\US Home\2005 Job Files\260253- Revisions.doc $$ FORM e.rJOA-2004 EnergyGauge@4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A US1353SC- ST; CROIX -1353 S.F. LIVING AREA Builder: U.S. HOMES ~:l\. 3 (Yl ~ Rd - fY'lcde l \ b Perm~tting Offic.e: ~_ cJf) ?-4J-f h.....-t ~I , .c;..e-{J h....K' \,,0.J....b) S-- Permit Number. ,") -J9~ LA. s I-\-c'^~ Jurisdiction Number: lo II (000 Central Project Name: Address: City, State: Owner: Climate Zone: I. New construction or existing New 2. Single family or multi-family Multi-family 3. Number of units, if multi-family 4 4. Number of Bedrooms 3 5. Is this a worst case? Yes 6. Conditioned floor area (ft>) 1353 ft2 7. Glass type 1 and area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A II. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft b. N/A 7b. (Clear) 185.0 ft2 R=O.O, 103.0(p) ft R=4.1, 691.0 ft2 R=4.1, 744.0 ft2 R=19.0, 692.0 ft2 12. Cooling systt;ms a. Central Unit Cap: 28.0 kBtu/hr SEER: 12.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 30.0 kBtu/hr HSPF: 7.80 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 b. N/A c. Conservation credits (HR.-Heat recovery, Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceilingfan, CV-Cross ventilation, HF- Whole house fan, PT -ProgralIUl1able Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.14 Total as-built points: 19573 Total base points: 20957 PASS~ I hereby certify that the plans and specifications covered by this calculation are in comg . ce . h the Flor' Energy Code. PREPARED BY: /'" DATE: ft- :Z.2--~LPS- I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.90 Florida Statutes. BUILDINq~ FI A: DATE: 2,,2.. <1 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@ (Version: FLRCSB v4.0) ._".-..,.... ,. ..l.~.. FORM 6UQA-2004 EnergyGauge@ 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A US1353SC- ST. CROIX - 1353 S.F. LIVING AREA Builder: U.S. HOMES Permitting Office: Permit Number: Jurisdiction Number: Project Name: Address: City, State: Owner: Climate Zone: Central New construction or existing New Single family or multi-family Multi-family Number of units, if multi-family 4 Number of Bedrooms 3 Is this a worst case? Yes Conditioned floor area (iF) 1353 ft2 Glass type I and area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic I. 2. 3. 4. 5. 6. 7, 7b. (Clear) 185.0 ft2 R=O.O, 103.0(p) ft R=4.I, 691.0 ft2 R=4.I, 744.0 ft2 R=19.0, 692.0 ft2 b. N/A c. N/A II. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):lnterior Sup. R=6.0, 150.0 ft b. N/A 12. Cooling systems a. Central Unit b.. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceilingfan, CV-Cross ventilation, HF- Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Cap: 28.0 kBtu/hr SEER: 12.00 Cap: 30.0 kBtu/hr HSPF: 7.80 Cap: 40.0 gallons EF:.0.92 Glass/Floor Area: 0.14 Total as-built points: 19573 Total base points: 20957 PASS~ I hereby certify that this building, as designed. is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@ (Version: FLRCSB v4.0) --.",.... . ,0(".'_ , FORM 600A-2004 EnergyGauge@4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1353.0 25.78 6278.5 Single, Clear SE 1.3 15.0 32.0 61.07 1.00 1953.3 Single, Clear SE 1,3 15.0 32.0 61.07 1.00 1953.3 Single, Clear SW 1.3 15.0 32.0 56.99 1.00 1820.0 Single, Clear SW 1.3 17.0 9.0 56.99 1.00 512.0 Single, Clear SW 1.3 9.0 16.0 56.99 0.98 896.7 Single, Clear SW 1.3 9.0 16.0 56.99 0.98 896.7 Single, Clear SE 1.3 6.0 16.0 61.07 0.92 897~3 Single, Clear SE 1.3 6.0 32.0 61.07 0.92 1794.5 As-Built Total: 185.0 10723.9 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 744.0 0.70 520.8 Concrete, Int Insul, Exterior 4.1 691.0 1.18 815.4 Exterior 691.0 1.90 1312.9 Concrete, Int Insul, Adjacent 4.1 744.0 0.65 479.9 Base Total: 1435.0 1833.7 As-Built Total: 1435.0 1295.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.20 144.0 Exterior 20.0 4.80 96.0 Base Total: 20.0 96.0 As-Built Total: 20.0 144.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 692.0 2.13 1474.0 Under Attic 19.0 692.0 2.82 X 1.00 1951.4 Base Total: 692.0 1474.0 As-Built Total: 692.0 1951.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 103.0(p) -31.8 -3275.4 Slab-On-Grade Edge Insulation 0.0 103.0(p -31.90 -3285.7 Raised 0.0 0.00 0.0 Base Total: -3275.4 As-Built Total: 103.0 -3285.7 INFILTRATION Area X BSPM = Points Area X SPM = Points 1353.0 14.31 19361.4 1353.0 14.31 19361.4 EnergyGauge@ DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 . FORM 6(lOA-2004 EnergyGauge@ 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Summer Base Points: 25768.2 Summer As-Built Points: 30190.3 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (OM x DSM x AHU) (sys 1: Central Unit 28000 btuh ,SEERlEFF(12.0) Ducts:Unc(S),Con(R),lnt(AH),R6,0(INS) 30190 1.00 (1.08 x 1.150 x 0,85) 0.284 1.000 9101.8 25768.2 0.4266 10992.7 30190.3 1.00 1.061 0.284 1.000 9101.8 EnergyGauge ™ DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 ......,...... -.."-0-. FORM 600A-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS-BUILT , GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1353.0 5.86 1427.1 Single, Clear SE 1.3 15.0 32.0 10.59 1.01 341.3 Single, Clear SE 1.3 15.0 32.0 10.59 1.01 341.3 Single, Clear SW 1.3 15.0 32.0 11.59 1.00 371.5 Single, Clear SW 1.3 17.0 9.0 11.59 1.00 104.5 Single, Clear SW 1.3 9.0 16.0 11.59 1.01 186.5 Single, Clear SW 1.3 9.0 16.0 11.59 1.01 186.5 Single, Clear SE 1.3 6.0 16.0 10.59 1.04 176.1 Single, Clear SE 1.3 6.0 32.0 10.59 1.04 352.1 As-Built Total: 185.0 2059.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 744.0 1.80 1339.2 Concrete, Int Insul, Exterior 4.1 691.0 3.31 2283.8 Exterior 691.0 2.00 1382.0 Concrete, Int Insul, Adjacent 4.1 744.0 2.08 1547.5 Base Total: 1435.0 2721.2 As-Built Total: 1435.0 3831.3 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.0 7.60 152.0 Exterior 20.0 5.10 102.0 Base Total: 20.0 102.0 As-Built Total: 20.0 152.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 692.0 0.64 442.9 Under Attic 19.0 692.0 0.87 X 1.00 602.0 Base Total: 692.0 442.9 As-Built Total: 692.0 602.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 103.0(p) -1.9 -195.7 Slab-On-Grade Edge Insulation 0.0 103.0(p 2.50 257.5 Raised 0.0 0.00 0.0 Base Total: -195.7 As-Built Total: 103.0 257.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 1353.0 -0.28 -378.8 1353.0 -0.28 -378,8 EnergyGauge@ DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 .~~~"~ ...""";-. FORM 6DOA-2004 EnergyGauge@4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Winter Base Points: 4118.7 Winter As-Built Points: 6523.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 30000 btuh ,EFF(7.8) Ducts:Unc(S),Con(R),lnt(AH),R6.0 6523.7 1.000 (1.068 x 1.160 x 0.87) 0.438 1.000 3090.8 4118.7 0.6274 2584.1 6523.7 1.00 1.083 0.438 1.000 3090.8 EnergyGauge™ DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 .~~...- .......'. . FORM 6!)OA-2004 EnergyGauge@ 4.0 l WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: I . BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier . 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 7380.0 As-Built Total: 7380.0 CODE COMPLIANCE STATUS ! BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 10993 2584 7380 20957 9102 3091 7380 19573 I PASS I EnergyGauge TM DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 ..-.,..~ .. ~/. FORM 600A-2004 EnergyGauge@4.0 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: , , , 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS Exterior Windows & Doors Exterior & Adjacent Walls SECTION 606.1.ABC.1.1 606.1.ABC.1.2.1 Floors 606.1.ABC.1.2.2 Ceilings 606.1.ABC.1.2.3 Recessed Lighting Fixtures 606.1.ABC.1.2.4 Multi-story Houses' Additional Infiltration reqts 606.1.ABC.1.2.5 606.1.ABC,1.3 PERMIT #: REQUIREMENTS FOR EACH PRACTICE CHECK Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation tothe top plate. Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0cfm from conditioned space, tested. Air barrier on perimeter of floor cavity between floors. Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. COMPONENTS Water Heaters SECTION 612.1 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) Swimming Pools & Spas 612.1 Shower heads Air Distribution Systems 612.1 610.1 HV AC Controls Insulation 607.1 604.1, 602.1 REQUIREMENTS CHECK Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker (electric) or cutoff (gas) mustbe provided. External or built-in heat trap required. Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. Separate readily accessible manual or automatic thermostat for each system. Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGauge™ DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 . ~ .. RIGHT-J SHORT FORM Entire House SIMPSON MECHANICAL 12302 N. NEBRASKA AVE., TAMPA, FL 33612 Phone: {613} 556-0656 Job: ST. CROIX - 1353 S.F. LIVING AREA 11/22/2005 Project Information For: U.S. HOMES Design Information Htg Outside db (OF) 40 Inside db ("F) 70 Design TD (OF) 30 Daily range Inside humidity (%) Moisture difference (gr/lb) Clg 95 75 20 M 50 47 Method Construction quality Fireplaces Infiltration Simplified Average o HEATING EQUIPMENT Make Carrier Trade WeatherMate 38EYG 38EYG03030/31 COOLING EQUIPMENT Make Carrier Trade WeatherMate 38EYG 38EYG03030/31 FX4BNF030 - 5 K.W. Efficiency Sensible cooling Latent cooling Total cooling Actual cooling fan Cooling air flow factor Efficiency Heating input Heating output Heating temperature rise Actual heating fan Heating air flow factor Space thermostat 7.8 HSPF 30000 27 1000 0.048 Btuh @ 47"F of cfm cfm/Btuh 2 STAGE HEA Load sensible heat ratio ROOM NAME Area Htg load Clg load (ft2) (Btuh) (Btuh) 342 4661 3599 163 5415 4772 120 1863 2275 33 240 59 42 611 151 43 207 252 160 1751 2135 160 2862 3172 195 2898 3267 52 246 300 44 73 113 LIVING DINING KITCHEN POWDER STAIRS HALL B.R.#2 B.R. # 3 MASTER B.R. MASTER BATH HALL BATH 12.0 SEER 22300 5700 28000 1000 0.050 Btuh Btuh Btuh cfm cfm/Btuh 83 % HtgAVF l ClgAVF (cfm) (cfm) 224 179 260 237 89 113 12 3 29. 8 10 13 84 106 137 158 139 163 12 15 4 6 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ..ss ,^,rlght:soft Right-Suite Residential'" 5.0.60 RSR29616 ~ \\Simpsonfileservlshareddocs\Tommy\My Documents\Wrightsofl HVAC\US1353SC.rsr 2005-Nov-22 10:39:03 Page 1 '-', ,~1"Il .. ""'... , .. Entire House dl 1353 I 20828 20095 100~ 1000 Ventilation air 0 0 100~ Equip. @ 1.00 RSM 20095 Latent cooling 4246 TOTALS 1353 20828 24341 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. A:::. vvnght:soft Right-Suite Residential'" 5,0.60 RSR29B1B )(;(),. \\Simpsonfileservlshareddocs\TommylMy Documents\Wrightsoft HVAC\US1353SC.rsr 2005-Nov-22 10:39:03 Page 2 . "-"-1-- __..t.... ". ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.4 The higher the score, the more efficient the home. 1. New construction or existing New 2. Single family or multi-family Multi-family 3. Number of units, if multi-family 4 4. Number of Bedrooms 3 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1353 ft2 7. Glass type I and area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic 7b. (Clear) 185.0 ft2 R=0.0,103.0(p)ft R=4.l, 691.0 ft2 R=4.l, 744.0 ft2 R=19.0, 692.0 ft2 b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft b. N/A 12. Cooling systems a. Central Unit Cap: 28.0 kBtu/hr SEER: 12.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 30.0 kBtu/hr HSPF: 7.80 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before [mal inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Horne: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP AlDOE EnergyStar1Mdesignation), your home may qualifY for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site atwww.fsec.ucfedufor iriformation and a list of certified Raters. For iriformation about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type. For actual glass type and are~ see Summer & Winter Glass output on~ges 2&4. . cnergyGauge@ (Version: FLRCSH v4.0) . -"t.-.,w ~ ..,.,,'. . - Fire Chief Robert Hartwig ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813) 780-0041 Fax (813) 780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: a -~ Business Name: 'b~, ~"- ~\nc\'l'l~ BusinessAddress: ~;. \.6..\~ ~ DJ Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES ~SitePlan ~ Building Plans ~ Revision .06 sf /t;5'1/,b STANDPIPE SYSTEM D Per Riser $25 SPRINKLER SYSTEMS D 0 - 25 Heads $30 D 26 plus Heads $60 FIRE PUMP D Per Pump $100 FIRE ALARM SYSTEM o 0 - 25 Devices $30 D 26 plus Devices $60 SUPPRESSION SYSTEMS ~ Wet $35 Dry $35 C02 $35 Other $35 INSPECTION FEES Annual N/C 1 st Re-inspection $25 2nd Re-inspection $50 3rd Re-inspection $125 4th Re-inspection $250 5th Re-Inspection $500 Construction $15 Commercial $25 SPRINKLER SYSTEMS Hydro Undergrounds $45 Hydrostatic System $45 Wet Acceptance $30 Dry Acceptance $45 Hydrant Flow $25 Hood / Booth $30 Grease Duct $15 FIRE ALARM SYSTEM D System Acceptance $50 D Recall Acceptance $50 OTHER Fire Wall/Smoke LP Gas Natural Gas Fuel Tanks Tent Billing Phone No.: Billing Fax No.: Contact: PERMIT FEE FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $25 5th Alarm $50 6th Alarm $75 7th Alarm $100 8th Alarm $150 9th Alarm $200 10th Alarm $250 Non Compliance $150 "Affidavit of Service/Repair" $25 $25 $15 SPRlhlKLER SYSTEMS D Automatic $15 FIRE PUMP o Fire Pump $15 FIRE ALARM SYSTEM o Detection $15 OTHER LP Gas Natural Gas Fire Works Fuel Tanks $45 $45 $25 $45 GREASENENTILATION GREASENENTILATION D Hood/Ducts $35 B Hood/Ducts $15 ~ Kitchen Suppression $15 PLANS TOTAL ~ INSPECTION TOTA~~ PERMIT TOTAL! I Comme~ k ~~F3v'J~'i~g ~~~kKl 01 FALSE ALARM I I TOTAL. 7' ?e. P<-A/L> , Date: Inspector: 2-/3/&? {~Y7 &r /Ve-I/ rA- ;(\ {'\ -=- (I ('I PERFORMANCE BUSINESS PRODUCTS. INC. 813-719-8008 FAX 813-719-7919 WATER ACCT. NO. ('I o (I o (i (i (1 CITY OF ZEPHYRHILLS ZEPHVRHILlS, FLORIDA ~ -(9 5s 7 DATE '3/30/6<0 . OWNER/ RENTER LA5~ MAILING "" '--- SERVICE ADDRESS (oQY3 SHUT OFF SERVICE 0 .,0..::,.. ~ TURN ON SERVICE ~ INSTALL METER ~ READ METER 0 CHECK METER 0 OTHER 0 mode-( yY)()-1. ~ 1-1'\- 10 I9""'~ATER t3~ o SEWER o GARBAGE G:YI"'N CITY o OUT CITY -L No. OF UNITS _ DEPOSIT AMOUNT 3/411 W~ ~ P.e(""~ - S5~%" WORK COMPLETED BY & DATE COMPLETED __ AMOUNT LAST Bill __ DATE _ MISC. CHARGE ORDER TAKEN BY Retain white form in office at all times. Send pink & yellow forms to Water Service Water Service Depl. to sign yellow form & return to office. .-1 09/25/2006 12:27 FAX 813 674 0823 F;'A'~;(~'O' 'CO'UN'l.'Y': . FL:.ihUA"" III 002/010 un........ v~;........,'V",... .......,:..." .c..V';';LO [)N"F~ACTOR th 0:J.EiHI9 AME:: STEVE R SMITH (mf~:: 15915 KING J'AMES COUHT /ST ;; OI)E~f.)SA Fl.. 3;555(.157~!8 PAGE:: 1 OF :t. ISSUE: OFF='J:CE::: N REcr::::r F'T NUMBR:: 0097;S~'i:!9 OFFICE:: NEW PORT RICHEY DR:: CHECK ~ 5170 CITY OF ZEPHYRHILLS SOLID WASTE ~5598 ONTRACTOR:: 015189 6243 MAISIE RD UNIT"10 TOTAL AMOUNT: 13~73 CeNT COMPNY ACC:dLlNT CENTEF~ AMOUNT ))ESCRIF'TION/PERI'tT nATA DFVCR 114 If.q~)() ~ 36::-:;O()0 ..:.-~ 13 ~ 73 *ifi(O*'~* SOLID WASTE FEE~ 60 ECEIVED BY _____.__~-_---__--_-------.---. 09/21/2005 21:21 8139482710 IH SUNCOAST HOMES PAGE 10/30 ~~~~~~!~JW' 1111111111 11I/111111111I1 IJlllllllllll 9{OI1C~ O:F COM!!v{tE9{CTM'Eg.{T -.......-:;;;""" . Rcpt: 1034111 DS: 0.00 09/19/0& Rec: 10.00 IT: 0.00 "_n n. .._,_. D~ty Clel"k Notice is hereby given that thc undersigned will commence (recommence) to 5::) 9 <6 improve the following described real propcrty, situated in ~asco County, Florida, to-wit: JED PITTMAN PASCO COUNTY CL.ERK 09/19/06 1!:53am 1 70f721 a) l-OT# ..~ OR BK 7186 PO Eiland Park 6243 Maisie Rd u.s. Home Corporation Central Florida Division 600 N. We~tshorc Blvd., Suite 600 Tampa, FL 33609 ~~~ ~ ~ S!2 ~ -- LLr I~~~,"~ Ii: d ........ :::l a:: ::i - . CJ :=Bc ~ ~ge:14 :5 ::""!O~ ~ :li=~.... N <O....152::~ OU1::....c:w -Cf)-fL.-CI) OO:<(:;;OQ....I Q.,w<">l.'I:c( -' ct;8 LL~~~~tt u.. !!? CC' u 0 O~ ~8~ ~zj;~ir< _ ::> < u.. i=:o ~o= CJ)() l=~~ ZeDhvrhi lJ,~"......1:,L_..33S40 b) c) Said improvements shall consist of: Multi.Family Residence The name and address of the owner of said real property is: d) Thc name: and address ofthe contractor is: Same as above e) The name and address of the surety on the payment bond under Section 713.23 FS is: Not Applicable/ Same as above The amount of such bond is $ N/ A f) The name and address of!:bc person upon whom notice~ or other documents may be served is: Not Applicable: g) The name and addn:!'ls of the: person de~ignated in addition to the undersigned, to rcceive a copy of the lienors notice as provided in Section 713.06 (2b) FS. is: h) notice:. Commencement of said improvement shall bc within thirty days from date of recording this Dated tllis 14th day of Seotember ,2006 r:--:::0 L: u}.J ~"'''':-:'J'''^ " . ., -l :. Prepared By: Kimberly Dauge:tte US Home Corporation 600 N. We!!ltshore Blvd. Suite 500 Tampa, FL 33609 - 1l..S.1lt. · Michael K. Steams Age:nt Who is personally known to me, Swom and subscribed before me this ]4 day of Septe:mber,2006 Notary Public: 1<llll LUJ.1.'1 Owner Authorized t-..C)(lU :iif1;! ..~'.. . - ijl'~;:'~'i~;.~. KIMBERLY KAV DAUGEl1'E ~/;'~~'7~ OJ,VCOM~ISS1ONlIDD45B541 ~ -.... ,- Yo,,!! EXPIRES. Seplember 10, 200ll ::1 ':'{~;':-f;;~<:'~" ~tof'.dc:dThfUNnl~Pubtlclltldorwrit... :;...~..;:~~~., . ~=~ Kimley-Horn and Associates, Inc. September 25, 2006 . 5344 Ninth Street Zephyrhills, Florida 33542 Mr. Bill Burgess Building Official City of Zephyrhills 5335 8th Street Zephyrhills, Florida 33540 ti 6~-5S~ SOf,j~. Loc~d) If") 5"15W Re: Eiland Park Townhomes - Lots 1-10 Dear Mr. Burgess: I have reviewed the As-Built Surveys of the lot grading for the above subject lots and find them in substantial conformance with the Lot Grading Plan previously approved by the City. The project is located east of Massey Road and south of Eiland Boulevard. At this time the plat has not been recorded and addresses have not been assigned. If you have any questions, please do not hesitate to contact me at (813) 788-0400. Sincerely, KIMLEY-HORN AND ASSOCIATES, INC. ai . omelison, P.E. nior Project Manager CLC:bas Attachment cc: Lennar Homes, Inc. H:\049791002 - Lennar Eiland Park\Lot Grade Letters - COZ\092506 Lots 1-IO.doc . TEL 813 788 0400 FAX 813 782 4978