Loading...
HomeMy WebLinkAbout06-5685 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 5685 ./ Permit Number: 5685 Permit Type: ADDITION/ALTERATION Class of Work: 434-ADD/AL T RESIDENTIAL Proposed Use: SINGLE FAMILY RESIDENTIAL Square Feet: Est. Value: Improv. Cost: 25,000.00 Date Issued: 5/04/2006 Total Fees: 450.00 Amount Paid: 450.00 Date Paid: 5/04/2006 Work Desc: RENOVATIONS-GENERAL Address: 39302 6TH AVE ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 12-26-21-0040-00100-0080 Name: FELIX, SUSANA & PENA, RAFAEL Address: 39302 6TH AVE ZEPHYRHILLS, FL. 33542 Phone: DA . REESE ELEC. WILLIAMS DENNIS (INDIVIDUAL) SONNY'S DISCOUNT APPLIANCE, INC. PLUMBING FEE 35.00 40.10 MECHANICAL FEE /LJ / CL L, l 0 . oLl f {7'\I~1 l> l (9V" NO 1 T R DUCTS INSTALLED CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATED PRE-METER WATER SHEATHING MISC SEWER MISC MISC MISC. MISC. MISC. MISC. MISC. DRIVEWAY MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)( c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. . ~-~ IGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CI~Y OF ZEPHYRHILLS PERMLT A~~~~~A~~U~ BUIILDING DEPARTMENT 5335 8TH St, Zephyrhills, FL 33542 813-780-0020 FAX:B13-780-0021 PHONE CONTACT . yll3 (dp DATE RECEIVED ~~ FOR PE'RMITTING~-,')714.if'2. 71 OWNER'S NAME 5"v,-/f# fi-~J(C i !?:rrA-,t;t.-!1::-AlFI- PHONE{$13) 7iS-... 6ttJtj' JOB ADDRESS .?q?t)~ 6 -filAr;!?: ~/fI(/iYll'a-~Fi. 3-3?~Z- LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION PARCEL ID 4/: ('Z- - tfR -1 {- oO'fo -00/00 -oogo (OBTAIN FROM PROPERTY TAX NOTICEl WORK PROPSED: 0 NEW CONSTRUCTION 0 ADDITION &AI:TERATION 0 REPAIR 0 INSTALL DSIGN o MOVE 0 DEMOLISH PROPOSED USE: ITJ:9'~L FAMILY DWELLING DMULTI-FAMILY D4/: OF UNITS o MOBILE HO~ o COMMERCIAL o INDUSTRIAL o SWIMMING POOL o OTHER c:J RESTAURANT & HEALTH DEPARTMENT APrROVAL DESCRIPTION OF WORK (9clUG'P.A-f... ?e-N'ov/fr/M}S ~g"VZ~ ' BUILDING SIZE /" "" SQUARE FOOTAGE /~-f~ , HEIGHT ~/ ~UILDING ~LECTRICAL ~ ~MBING ~MECHANICAL o GAS ~OFING 0 SPECIALTY TYPE OF CONSTRUCTION: ~LOCK RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERM~T ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTR~CTIOtE:.-- J'o.,J I r-=::::.. \~ '.. ' --~~ ~~)j~b PERMITS REQUESTED-~ r..lig::rr~ -rr.."., ~1"' I t.k!~Ll':" WI\..-\.. ~~~~~-'. .('\ .-' ~~:r;-~ \. ~ ~ L ~!4iU VALUATION OF TOTAL CO~fl-- -------- S""q-, 'i 1.2-- 14r< J) 11 c sv-p it Wi ('11) L ~ :4-1). AMP SERVICE 0 Progress Energy 0 W.R.E.C. ~a.~ - hPk~&. / No€-- ~ $ Z~c>~o. /~c> c>P - "0 $ .3; ~t9o.. - VALUATION OF'MECHANCIAL INSTALLATION o OTHER o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES [g-NO BUILDER SIGNATURE STATE CERT OR REGIST # t! a..e. ~6o 3/ **************************************************** ELECTRICIAN SIGNATURE ~1i-~\L.~ s-e,7G COMPANY_()e...eS~ trl.e~'t\l':-~"'\ r.M:'. . 1 STATE CERT OR REGIST # [Z~\~oa\~~~ ~ MECHANICAL ******************************************** 3 5"..'d:> COMPANY c s;;- N' ~ I.J @ COMPANY ~~~~...'S \~~\"-~<, ,~~~ STATE CERT OR REGIST #0 ~ ~'-- \ ({ ;;). ~~~ @ I1-M' (JJ)F~c'1 ****************************************************************** PLUMBER ~:..(6" #0 SIGNATURE SIGNATURE STATE CERT OR REGIST * ********************************************~****~*************** OTHER COMPANY SIGNATURE STATE CERT OR REGIST * A. NOTI~E OF DEED RESTRICTIONS Th~ undersigned understands that this permit may be subject to "deed restrictions" which may be more restrictive than City regulations. The undersigned assumes responsibility for .'co~lia.nce tiith any appiicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contr~~tors to undertake work, 'they may be required to pe licensed in accordance with state and local regulations. If the contractor is not llcensed as required by law, both the owner and contractor maybe cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign po~tions of the "Contractor Sections" of this ~pplication for which they will be responsible. If you, .as the owqer~igns ~s ~h~ contractor, you are indicating that you, rather than the contractor, are responsible for the work: If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C.' TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, haye been provided with a copy 'of "Florida's Construction lien Law _ Homeowner's ,Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuahce of a permit and that all work wiil be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I ,understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies inolude but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetiand Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certity that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is understood that a drainage plan addressing a;:'compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit . ,. J.ssuance. A permit issued shall.be .construed to be a license to proceed with the work and not as authority to violate, ,cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for \a period of six months after the time,the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to'the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAY! ICE FOR IMPROVEMENTS 'TO. YOUR PROPERTY., IE'~... N. TEND TO, OBTAIN FINANCING, CONSULT W H YOUR LENDER OR AN ATTO BEFORE RECORDING Y tlRNO~ICE OF COMMENCEMENT. JOBS UNDER 2,500 I VALUE DO OT N RECORD AND POST A NOTICE/OF COMMENCEMENT". ~ / acknowledged , 20-- STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____day of by STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____ day of by . acknowledged l 20_ (name of persor acknowledged) [1ho is personally known to me, or (name' of person acknowledged) o who is personally known to me, . or o who has produced (type and wnoO did 0 did not of identification) take an oath. o who has produced (type of identification) and who Odid DHd not take an oath Signature of person taking acknowledgment Signature of person taking acknowledgement Name typed, printed or stamped Name typed, printed or stamped [!] .;F:~' PHILIPPI ASSOCIA TES P.A. Member of the American Institute of Architects 3637 Fourth Street North, Suite 230, St. Petersburg, FL 33704 727-822-7526 (fax): 727-822-5263 (e-mail): rcphilippi@ao1.com (url): www.Philippiarch.com April 10, 2006 03-0300 VIA FAXSIMILE 352-523-2802 (Contractor) 813-780-0021 (Bldg. Dept) 727-834-3450 (Pasco Cty Com. Dev.) City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, FL 33542 Attn: Mr. Bill Burgess, Head Inspector Building Inspector Re: Renovations to the residence of Susan Felix and Rafael Pena 39302 6th Avenue Zephyrhills, Florida 33542 Dear Sir: We are the consulting architects for the Pasco County Community Development Department and the replacement of the roof and related renovations at the above referenced site. Last week I wrote you concerning matters related to the existing construction of the above referenced home. It is my understanding that you have asked that I confirm the capability of the exterior wall system to support the superimposed new roof structure proposed for the home. The foundation of the home has been exposed to reveal a stem wall with reinforced concrete footings properly below the surface and approximately 20" wide x 12" deep. There is no visual evidence of any cracking or settlement of the outside walls at this time. Steel reinforcing in the masonry exterior walls has been confirmed as previously explained in my last letter. Based on this new information I confirm that the exterior walls have the structural capacity to support the additional roof structure. No subsurface investigations have been taken so the nature of below grade materials and their effect on the structure can not been evaluated. Please do not hesitate to call this office at 727-822-7526 regarding any questions you may have concerning the work at this residence. Very truly yours, d~~ ~~iPPi, AlA, NCARB FIReg.0008813 /~\\1 \\Bank\documents\PHILlPPI\PHILlPPI\PASCO COMMUNITY DEVELOPMENT\03-0300\Letters PI,.. "17 I.AWll ... "113 BRMINOUl POIIM4111 NOTICE OF COMI\IENCEMENT 11'_&.. IN .-u.-Utl .YI.. 8role of ..tluldart) } C,)unty Qr r 'I'r$ c,o \ Tha undl!lralgnud lutrobv inform. all GrlnD.rn" th.t ImpralHUY.llr ID VIlli. III! n ad with sectlo... 71 ~1. 13 of lh. &llurld. 9t1dt,ae.. iha followind infnrMS 'Ian 10 8'ltlt~d ;:. ttr11 ,lIl1rNI.o,nT1rUd' pmp8r1'. Qnd In QlIuordancf . III CE 0 F CcJMMBNCl!MINT. Oaacrlptfpn o'prupuny _ .I.'!::.:.'?~~.?:I.-::.t?f?'f:?:-: OO{OO - 04>~O . . ~ . ......_........ .........................a...................................................... . . . . . . . . . . ~~~~~~~I~!W'lllllllllllllll 1111I 1111111111111I111I . ...................... ............. ..-........... ...~................. .............. ........ ............. .f.........- B f.tf~!(It1/P.t!.;? ! tfo.qF ';;;'. ~i.~l@..~.. :....... '. ..... ...... . . . .. . . . . . 5 · -;/ ~ P (-! -.-........-.- Ownllr .... .t!~(t#1f.61f~.f.\-!t6fFh.._If."I."'".. ...... ........--.. ..-' ......... ........... ............ .-....-...- AddroslI . 3 ?? t?~. .. (t;. . . .It.t(~.. . Z. ~t(r!l!t.'k~6... ? ~~?( ~ Rcpl : 991123 DS: 0.00 Rec: 10.00 04/24/06 IT: 0.00 Dpty Clerk ..' ~ ........ ... _.. ....~........._....._................. ,'0'. Owner's inter.sIIn.lta Df dUllmptoWlhl8llt ... . . . . . . . . . . . . . . . . . .. . . . Fl;Is SImple Thll. hold., or othur titan awOll" .,............. Nama ..,...........,......... - . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~592~}~~M~~~~ASC01COUNTY CLERK -.......... OR BK 6949 PGoi455 At(drssa ............................................................ ....................... - . . . . c......_ylfrl. If). W ,.~IjN5.~N.lfI.~I.W!fi!:... .. ...................... _..:: ::::.:.::::.:. :::: :::::: Add,s.. . .rf"~.~ .t:P~'C.ti/N~f<M/).. .ll~~ 4/"0;:::b: .~.J.$.?--5.........................._....... R Surltty (il allY) .................................................. - - . .' ........ - .. . . . - . . . . . . . - . . . . . . . . . . . . . . . . . . ., . . . . . . . . .. . . . . . AddrOBIJo . ..... _. . . . . . . . . . . . . . . . . . .. . .. .... . .. . . . . . . - . - . . ., . . . . . .' ., . - . . . . . . . . . . - . . . . - . . . . . . . AIUftum of bond II . . . . . . . . . . - . . . . Any person malting" loan tor lhBllollall1lDllon of the ImprovumollGc Nairne .............. .'. .. . . . . . . ..., ., ........ .. . , ..... ... . .... . . ..... . .. .. . . . .. .. .. .. .. .. . .... .. . .. . .. ,. . . , . .. . . . . . ... .... . . .. , .... . . . . . . .. .. .. .. .. . .. .. .. . . Address .."" ,.........,....... . . . . . . . . - . . . . . . . . . . . .' . . . . . . . . . . . . - .......................................................... Per!lDn within 'tho SIIIIII of Florida dll8lgn..d by owne, upon Whl m ..oiiauu or alher dOl,lumonlB mav bo 'Drvad: Nal11tt .Pij?t?CPr)~tf_.CJ?!m.(":J.o.J!././.iyV8f/J:3.UJ.e1AEAJr...... -........ --." ...... .., ... .....,.. Addrallli . . . . . . . . . . . . - . . . . . . - . . . . . . . . . . . . . . . . . . .. .' - . . . . . . . . . . . . . . . . . ., . . . . . . . . . . . . . . . . . . - - . . . . . . . . . . . . . . . . tl'\ l!L1lUtll'l~ 'I~ 'l~i~I~~I;~ ~~~r delitunllto thll fallallllna pareo.. to re ,siva . oupy of the UtlIID"9 NotllDl au provided In SoC1~O 713.13 (11 lh). "aridll Slstutes. ..UI (II ..l ownu....s opti...J. NSlno . . . . ... . . , . . . . . ~ . . - - , . ..u. ..' ..-~-.- -. . .. . . . -.. . . . . . . . - . .. .......... -' .. . . . . . . . . . . . . . . .. . . . . . . - . . ., . . . . . . . . . ., . . - . . , STAT::~~~~~;~~~.;~~~~~~~~~~~~~~.'.. -,. ..-.. f. //:J3:/if.... '~~~... . . ...... ..... -' ..... ........ COUNTY OF PASCO ;L:.~ to 81 d lIubBoribRd bata... roo this. . .., .,. .... ..... . .. . THIS IS TO CERTIFY THAT THE FOREGOING IS A . t. - 6 2"" 10 ~~U~:~~8~?~~~~1~g~~ ~~i~~~~g~~~1~:SF~~ ......9..1:..... .dRV Qt .,. .t-.\. . (~.<: ~. . - . . . . .' . . . .. . . . . .. .18_.... HAND ANO OFFICIAL SEAL THIS~ DAY OF ?... ~_. If PIC ~ . .. .. . t/~.. ... "'o~;;. P~;~I~~' . .. ... . . . . . JED ~rrMAN,/~L~R~OFCIRCUITCOURT IJ {) .1 p.f (}1,Jtri L.~...-..t.. .it O<3'I/b" BY ,,(/JJ,fiL1/A. Jliili~ DEPUTY CLERK /)rGJ"V. r....~. ro f-_v II'. J I rJ t1'1'L' H Ci.aD -11()- .3'6. ~J.f. - 0 {)(~tI';lA.(; t"'" J..... , _...:::;;..~..~,~ CRAiG SMITH ~'. ,,"'f~ MY COMMISSION # 00494741 ~'. EXPIRES: November 29, 2009 '. Bcnded'T1vU NoIBrY PublIc \lnd8IWIhl8 CUM TOTAL INTERIOR , SPEC# WORK AND DESCRIPTION LOCA TION 18/19 ALL FLOORING COVERING/CARPET Remove existing flooring and pad, dispose off the premises. Install new carpet over padding. (Included are all closets opening into rooms to be carpeted). BEDROOM #1 BEDROOM #2 24 BASE AND SHOE MOULDING Remove base moulding as required to install new flooring. Install new wood base on all walls. Moulding to match existing in the home. BEDROOM #1 BEDROOM #2 57/62 INTERIOR WALL FINISH _ PLASTER/DRYWALL REPAIR Wnere wall AlC has been removed, repair wall to match existing adjacent walls. Include new insulation as required. FLORIDA ROOM 62 CERAMIC TILE (THIN SET) Remove existing masonite board on walls. Furnish and install new wall board surround at the tub. Install new ceramic tile full height to ceiling. (Color selection by owner.) BATH 63 FIXTURE SET Reinstall existing fixture set as required. BATH 64/65 INTERIOR CEILING FINISH _ PLASTER/DRYWALL REPAIR Ceiling has been water stained and/or damaged. Repair ceiling finishes to match adjacent Sound ceiling finishes. ALL DAMAGED CEILINGS 72 INTERIOR DOORS Install owner supplied doors at Bedroom #2 clothes closet. BEDROOM #2 82 ELECTRICAL WORK Add two new wall outlets. FLORIDA ROOM Convert three outlets to GFCI. (1)BATH (2)K/TCHEN Add one new GFCI counter height. KITCHEN PAGE TOTAL Felix-PenawwRevised122BOS CUM TOTAL December 28. 2005 SPEC# 82 83 86 91 INTERIOR WORK AND DESCRIPTION ELECTRICAL WORK CONT Install three new hard wired smoke detectors. Install arc-fault circuit interrupters, one required at each bedroom. Install a new bath exhaust fan (ducted). Include a new switch. Check all existing wiring, switches, outlets for shorts or malfunction. Check and replace as required all electrical components per provisions of paragraph 82k. ENTIRE HOUSE H.V.A.C. Remove the existing AJC unit. Install a new 2.5T central heating and air conditioning system complete with all controls and electrical. (Minimum SEER required - 13.0) 10KW heat strip. Standard air cooled condensing unit set on a concrete pad. (Heat pump not required) Modify all existing ductwork and registers to code as required for new system) Check ductwork for leaks and damage. Include new duct work and register for the Florida Room. ENTIRE HOUSE MAJOR APPLIANCES Furnish and install a new 18 cu. ft. refrigerator/freezer. Remove the existing and connect the new. KITCHEN PAINTING - GENERAL SPECIFICATIONS Paint the entire Kitchen, Dining Area, and Bedrooms. This includes doors, ceilings, walls and trim. KITCHEN DINING AREA BEDROOMS Paint all areas where ceilings and walls have been repaired. Paint areas to match existing adjacent areas. Ceiling areas that have texture. match to existing. ENTIRE HOUSE PERMITS AND FEES $ CLEAN UP $ PAGE TOTAL $ TOTAL RENOVATION $ Fefix-PenawwRevlsed 122805 December 28, 2005 $ $ SPEC# 91 92 EXTERIOR WORK AND DESCRIPTION PAINTING - GENERAL SPECIFICATIONS Pressure clean and paint the entire exterior of the house including all wood, stucco and trim. Do not paint any items that are pre-finished. LANDSCAPING Trim all tree branches and vegetation within six feet of the roof and as required to facilitate proper painting of all exterior surfaces to be painted and to allow for new roof. F ellx-PenawwRevised 122805 CUM TOTAL LOCA nON ENTIRE HOUSE ENTIRE HOUSE fA 6E ""-01"1IL- (..U^I -r tJ'O'f-i- PAGE TOTAL $ CUM TOTAL $ December 28. 2005 CUM TOTAL EXTERIOR SPEC# WORK AND DESCRIPTION LOCATION 48 GUTTERS, DOWNSPOUTS Replace all existing gutters and downspouts with new. New gutters to be of the seamress type. ENTIRE HOUSE 49/50 ROOFING - GENERAL SPECIFICATIONS ROOFING - FIBERGLASS SHINGLES Install a new Class "A. fiberglass dimensional shingle roof per all requirements of the specifications and applicable codes. Drip edge to be installed over edge of fascia board. Color of drip edge white. ROOF 55 CEILING INSULATION New insulation as required to achieve R-30. ENTIRE HOUSE 70 ATTIC ACCESS Install a ceiling access panel to minimum clearing opening of 22" x 36". Provide cover and trim opening. GARAGE 82 ELECTRICAL WORK Install a new 150 Amp. exterior entrance service and panel. Remove all existing electrical and conduit as required. LAUNDRY! EXTERIOR Install a new exterior light with a new interior switch. FLORIDA ROOM Install new exterior, waterproof GFCI outlet at the AlC condenser. EXTERIOR Convert outlet at existing washer location to a GFCI. GARAGE 83 H.V.A.C. See Interior Spec. #83. INFO ONLY 89 PEST EXTERMINATION Inspect house for tennite and/or other insect infestation. If active infestation. tent or treat as required guarantee destruction of pests. (Std. Housing Code 307.5) ENTIRE HOUSE PAGE TOTAL CUM TOTAL F elix-PenawwRevlsed 122805 December 28, 2005 RENOVATIONS TO THE EXISTING RESIDENCE EXTERIOR SPEC# WORK AND DESCRIPTION LOCATION 11/25 CARPENTRY - GENERAL SPECIFICATIONSI WALL FRAMING Remove wall AlC' and frame close opening. Finish Exterior to match existing adjacent walls. (All Interior work under the Interior portion of this write-up.) FLORIDA ROOM ROOF FRAMING - GENERAL SPECIFICATIONS The entire house to have a new truss framed roof installed over the existing roof. Remove eaves as required. Refer to roof Faming plan, section, and details. Cut hole in sheathing as required for pitched roof over the covered entry area. MAIN ROOF 27 Roof framing and sheathing. All roof framing tied to walls with hurricane clips per 2005 Florida Building Code. Furnish drawings signed and sealed by a licensed engineer in the state of Florida when using truss framing. Include new 6"xS" P.T. posts and 3-2"x12" beams. Remove existing metal posts. New foundation as required for new posts. ROOF OVER COVERE ENTRY AREA 28 ROOF SHEATHING Install new roof sheathing as required to meet local codes and for the installation of new roof covering materials. ENTIRE HOUSE 29 GABLED ENDS Install at all gable ends new louvers and gable end vents. Screening required. Size:2/0 x 2/0 (min.) Include new horizontal vinyl siding per manufacture specifications. ALL GABLE ENOS 30 ATTIC VENTILATION Install at ridges new 10' long ridge vents. (Four total) ROOF 43 SOFFIT AND FASCIA - ALUMINUM Remove all areas of rotted, decayed fascia and soffit. Replace all rotted wood removed with new sound wood sufficient for nailing new aluminum fascia and vented soffit. ALL SOFFITS Enclose all soffit with vented aluminum or vinyl soffit and enclose all fascia boards with new aluminum baked finish. Soffit and fascia to be white. ENTIRE HOUSE PAGE TOTAL CUM TOTAL F elix-PenawwRevised 122805 December 28, 2005 47' -11 " t i I 2 7 :1/ I N · .~ 'II "'~ ;1d1! 1;11 _. ,~ U -5": &~ "a 'a g.g. i& e Ii ..,; g .0 ('oj ~5! 0" W::I ~a ~~~~ .P"")Lf)N t.g~? ~.~~~ -~~ 3 ~~~ ~~CC .c~lDt) ~~]E ~ 0. i-n U)..J1io "lU1>-u.. 10'-6" ~ \ 2\ \ ~~ LIVING AREA --~ t .- I <.0 N GARAGE I I / / -<Y / I \ \ -<> DINING AREA I / I / -<v/ 13' -11" Itl~ l,g~ 1 t .8 i~ j3'i1'i1 Jii rl~ I KITCHEN - ---~ en I . ~ ~ 20' -8 1/2" G WASH DRYER ~ o o FLORIDA ROOM c: o '(ii '5O Q) a:: b .- I '0 ..- ci z Dote 09-07-05 Drown By: EP Checked By: RCP BUILDING SHALL COM.PL Y WITH ALL APPliCABLE BUILDING, ELECTRICAL, PLUMBING AND MECHANlCAL CODES. r- --I : WAL4 I A/CI L_ __..J E eg l~ ; C ~iJJl:I ~ C l:I 'V .. =' Ill:.c 'I: 9 a g.1 iO~ ~ Il.~~i 1 D.~!~:F :I ]s i;: 12'-1 1/2" 21'-9 1/2" 14'-0" REVIEW DATE:~O'>- ClTY OF ZEPHYRHJLL~ iKt. BUILDING OFFICIALldL~)/"'J, EXISTING FLOOR PLAN C9 . ommlssion I 03- 0300 Drawing A1 ~i\bOms. ~ \ BED~t~~lil#2\ \ Rt:MO~ EXlSTlNG Ale UNIT AND INSTALL .l. NEW 2.5 TON SYSTEM, ALL NEW CONTROLS AND 'MRING AS REQUIRED! a-iECK ALL DUCTS FOR LEAKS AND DAMAGE. I BEDROOM #1 // NEW CARPET -<)-/ CUT ROOF SHEA IHIN AS REQUIRED TO ALLOW FOR ~NT1LA TION. 2X8 RIDGE (CONVENTIONAL FRAM NG) OUTRIGGERS R TIES ~N>> ~~o &t~SSES, NEW 7 ROOF FRAMING FOR FLORIDA FROM I I \ \ -<r DINING AREA N~~f~~~ I FLORIDA ROOM ~,it~NO ~~~TO CEJUNG. COLOR SELECTION BY O'M'lER. LIVING AREA 9&*'~~T KITCHEN I / / I -<Y SEW ~_~&~D [it- .~ 'II ii1;. ~a _8 ~~ q 8" """:..c &.~ ~~ i& ~ . .:.:~ ~ ~.:J N I a: .!~W::l ~~~~ "'lLl'lN .rIof'-LI'l ~:gc!.c!. Z.2~~ iil.J.....Rr:::- " t;;J')NN ~~~ :5~~~ .;;,g.~ i' a.. 0. rn "'l "" ~~;!~ ~~ INSTAId- Nk~ --, Wtl:. t~'i, I " 1 ~8'v1flfu.POOINf' I GARAGE -.-J il~~~:~ ------4 !If!t~ i~ 1~ I ,1lr- .Ii !hl" GWAS Ql -0 Cl c: o 'iji .:> Ql C!: d z Date 09-07-05 Drawn By. EP Checked 8 y. RCP ~ g ~ j &'t a t ~ ~i~t" ~ ::s l CiC .t: 'i "'15 c3 0 ~ iirl: ~ !lON"ICt 0& .?5 ~.1 L~;!~l . ~. i ! ~ S~ : c a om mission I NORTH RENOVA TED FLOOR PLAN C9 03-0300 Drawing A 2 2"Xf' QUTRIGGER'" @ 2 -0 a.c. ~ DROPPED GABLE END TRUSS. EACH GABLE. . I" <0 N I I I I I I I I I I I I : ; I I I I /~ I I I I /1'1 I I . - I" a - - -- -- o W' cr:: v W N ~ @ 13 C/) z w WC/) IC/) w ~ g: ~ OU TR~GGERS @ 16 O.C. -- -- -- -- -- -- -------- u o 3-2"X12" BEAMS,! GABLE END TRUSSE~ / MA TCH EXISTING OVERHANG, 101( ~ , ~v / - --- . ,. ., ". . , " .'" .. '". -. ..:. ~-----'----' ---'----::- ..l~_4 ~ ~~5s~twl~E~~~O fIT:-- f- -~._=:: K/ ~ . I' I .' ..:~: ~ I. I.; ~... " ~~ L -.' f- -~ _ I ~r~.. I """'" // I~( I I I I I I I I I I I I I I I I I [ -0. ~ ~ -2- NEW EN F OT LC \lG RI GE V NTS, J u u 0 0 a 0 w' w . cr:: v a::: '<t w N W N W @ W @ Z z 13 C/) (3 C/) Z w z w w C/) w C/) I C/) I C/) W ~ w ::) cr:: g: a::: g: no CL - -- -- -- -- 12'-1 1/2" -- -- -- -- -- --1- -- -_1-- '--- f-- f-- f-- '-- '-- I- I I I I I I I I I I L_____________J SEE SHEET A- 2 14'-0. I I I I- I I I I I EXISTING EXTERIOR WALL LINE. (TYPICAL) ROOF FRAMING PLAN SCALE: 3/16" =,. - 0" -p, T. 6"X6" POST REMOVE EXISTiNG METAL POSTS. t~lE~~~O~.ALL ~~~6~~fGTtS et~q~/r?~. N · ,~ l4a 3~ NO .8 ~:t !!i!l~ B.IJ~il JI,Ij:r-&~ J;g: h~ ~@ -5-5 ia II c.0- e$ ~ o ~l' ;:J ~~ G'ltl.t..J:::::> ~o Jl"''''''''' .~~~ ~-8~~ O'CNN ~~~ : a.~ ~ ~ 5CC ~i.,u ....~c= -tq;,gE ~~~.~ (Q..... a>> 0 I"'lVlf-u. <l> '0 Cl c o '(ii 'j; Q) Cl:: ci Z Dote 09-07-05 Drawn By: EP Checked By: RCP e 2 g ~ It ~ ~i].lo ~ ~ e& ~ ~ <3 i'2i~ j ~J~~i ff .e l:;! st{ to. 1c j ~ jJ N ommiss;on I 03-0300 AW2-2 SEE TY?ICAL SEC110N DRAWING A-4 SEE SECTION DRAWING 3, A-4. ;I- .~ ,. 3~ Mu _8 -.:1 GABLE END TRUSS. BUILDING ELEVATION @ GABLE END ftl~l,g,!l 1- lh. :t .8 Q-- jlt l'iL Ji!r- f SCALE: 3/15.=1'-0. NEW PRE-ENGINEERED ROOF TRUSSES @ 2'-0. D.C. SHOP DRAWINGS REQUIRED .,..---........... " " / \ I ( \ \ \ "- "- ~SEE TY?ICAL ...- ~_ SEC110N DRAWING " A-4 ,/ "- / "\ \ \ I / / ,/ w '0 a c: o '(ij '5 Ql a:: / / ,/ ......- XlSTING ROOF SLOPE 1/12. \ \ "- "- ci z Date 09-07-05 Drawn By: EP Checked By: RCP GRADE e eo Ii ~ ~ ~iJlQ 1 C O-"CII . ::I "',,:"C [i] 0> ~." _ Q U 0 c l6G: "CII ;10<<.5 lJ&JS~! c lLl.-: ~t 0> Is !] TYPICAL SECTION THROUGH THE BUILDING SCALE: 3/15.=1'-0. Drawing A3 U "5-5 i.2 ~~ :[if ~ Ii .:..:~ g .S N =f5! ~"It-u.J::;:) 3RIO~ V1::i~~ E.g~? ~.~~~ _ G: ;e.~ 3 ~~~ ~~Ct:, J:f:'!.... ~~~E f'. a.. 0. ai ~...;.;g ..,V1>-1.l.. ~ I: ~ "- ~ 03-0300 2"X4" UPPER CHORD @ 4/12 PITCH. SCISSORS TRUS 2"X4" LOWER CHORD 2/12 PITCH NEW CLASS "A., 30 YEAR FIBERGlASS DIMENSIONAL SHINGLES. NOTES: IT IS ASSUMED THAT THE EXISTING ROOF JOISTS ARE llED DOWN TO THE BEARING WALLS. IF NOT, llE DOWNS AS REQUIRED BY CODE W1LL BE A CHANGE ORDER TO THE CONTRACT. ;t.uj ~. ~. 1iI(t: ;1~ "0 =S ,.:1 H ~-fi t.~ .2-.9- ~~ o.Cl. ~ . ""~ g '0 N =fci! G..rW:::' "0 ~~~:6 . """ N .&:.of"1O 'G:gJ.J, ~~~~ ~ ~~~ ~~CC :S;~~ ~ .. i .s r:;Cl.g.~ co"":liio I"lVl....l.i.. 1 51 ROOFING FEI. T. 4 PL Y, 1/2" PLYWOOD. ROOF SHEAn-l\NG, EXT. GRADE. NAILED TO RAFTERS e. D.C. (USE 'H' CliPS AT EDGES 18 GA. STRAP TO PLATE I) EACH TRUSS. 2.x2" SQUARE WASHERS TAP CON WEDGE ANCHORS 1/2" DIAMETER ROO 32" D.C. S" EMBEDMENT CAPACHY AT EACH ANCHOR 12,OS4 LBS. 1/2" PI. YWOOO CLOSURE PIECE TO SEAL OFF EXISTING COF JOISTS. NEW 6" BLANKET INSULATION. (R-19) EXISTING ROOF' COI;tRING AND SHEA THING TO REMAIN. ALUM. COI;tRING OVER NEW FASCIA EXISTING CEILING TO REMAIN. 1"xe. P.T. FASClA WITH ALUM. COI;tRING INSULA TION BAFFLE !!~I~il"~ t .s - 1~:J'I;1 1I.1~ r'i6! ~sQll1i.ii EXISTING ROOF STRUCT\.JRE 1/12 PITCH. (ASSUME 2"X ? @ 16" D.C.) SECTION HUGHES HC10 W/ 9- 10d fTD BOTH BRACE &: TRUSS SIMPSON A34 EACH SIDE 2801 LOAD EACH 2"X4" OUTRIGGERS tMOVE EXIST. OVERHANG AS REQUIRED. "XS" TRIM EXISTING WALL (6) PARTIAL WALL N.T.S. ~I~~D T~~BSs~~rtCff B~UST A PROFESSIONAL ENGINEER, BE 2-16d COMMON I) 1e" O.C. 2x4 WOo BLOCKING 1'-4" 2x4 HOR. BRACING @ 48" O.C. MAX. B o Cl c o 'fii '5 OIl a:: d z Dote 09-07-05 Drown By: EP Checked By: RCP CLASS" A", 30 YEAR FIBERGLASS DIMENSIONAL 3/+" GALVANIZED FASTENERS WITH 3/8" HEAD. 4 FASTtNERS PER STRIP. - PRE-FAB ROOF TRUSS @ 24' O.G. (\ 5 FELT APPLIED WITH A 1 g" THEN COVER WITH A 36" LAYER, THEN CONTINUE OVERLAPPING LAYERS 19" TO RIDGE. GA8LE END TRUSS. E ~ g ~ I:. Sf ~ij~~ 1 c: ~....." :I .c 'C. <3 5'~;S~ v. I]~~j J L;$!~t jl ! IMPSON A34 EACH SIDE 2801 LOAD EACH ON 1/2' EXTERIOR GRADE 4 PLY, PLYWOOD FASTENED TO RAfTERS WI]i 8d NAILS 6 O.C. AT EDGE::; AND AT INTERMEDIATE SUPPORTS. ~ BLOCKING FOR SHEATHING 2x4 0 48" O.C. NAILING AS REQUIRED. ATTACHED TO BOTTOM CHORD OF TRUSS. 03- 0300 REMOVE EXISllNG~ OVERHANG. @ TYPICAL ROOF COVERING A4 ~GABLE & CONST. END BRACNI.~? Drawing A4 N.T.S. EXISTING BLDG. END WALL