HomeMy WebLinkAbout06-5694
..
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
5694
Permit #: 5694 Issued: 4/20/2006
Permit Type: GENERAL BUILDING PERMIT
Class of Work: 1 05-NEW CONST/MUL TI 5+ UNIT
Proposed Use: TOWNHOMES
Sq. Feet: Est. Value:
Cost: 83,150.00 Total Fees: 7,753.69
Amount Paid: 7,753.69 Date Paid: 4/20/2006
Name: US HOME ORP RATION
Addr: 600 N WESTSHORE BLVD, STE 600
TAMPA, FL 33609
Phone: 813854-4608 Lic: Phone:
Work Desc: NEW TOWNHOME-SIESTA-BLDG 2-#3
Address: AARAL YN RD MODEL 3 BLD 2
3'153'-\ ZEPHYRHILLS, FL.
Township: Range:
Lot(s): Block: Section:
Book: Page:
Subdivision: EILAND PARK TOWNHOMES
Parcel Number: Q3-d.(rO\\ -0230-00000 - 0\30
IL
MECHANICAL FEE
WATER CONNECTION RESIDENl
FIRE IMPACT FEE
FIRE INSPECTION FEES
SCHOOL IMPACT FEE 1%
73.27 RADON
419.00 WATER METER RES 3/4"
273.00 PUBLIC SAFETY 5%
13.50 PARK FEES TOWNHOMES
15.55 TRAFFIC IMPACT FEE 99%
1 .
16.63 SEWER CONNECTION RESIDENl
180.00 POLICE IMPACT FEE
26.35 FIRE PLAN REVIEW FEES
769.56 SCHOOL IMPACT FEE/100%
1,572.12 TRAFFIC IMPACT FEE 1%
1 .
1,616.00
254.00
62.18
1,555.00
15.88
F E
DUCTS INSTALLED PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB
DUCTS INSULATED LINTEL PRE-METER WATER
SHEATHING FRAME MISC SEWER
MISC INSULATION WALL MISC MISC.
MISC. INSULATION CEILING MISC. MISC.
MISC. DRIVEWAY MISC. MISC.
REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work: resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
.. ~~
S NATURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
corer
· S resft
CI~Y OF ZEPHYRHILLS PERMIT APPLICATION
BUI1'LDING DEPARTMENT 5335 8TH st, Zephyrhills, FL 33542
~ 813-780-0020 FAX: 813-780-0021 d I. C
, I DATE RECEIVED ,- ~- (p
I PHONE CONTACT FOR PERMITTING (813) 610 -18 8S""
JOB ADDRESS
APreA k" n (2t')
PHONE 81 ~ - ? (.9 - 5".;)'7 '7
~(j6d; /I!r/B1JOl3-
OWNER'S NAME
uS' //ome
() /lilt "'2>
C, Ittt-70/l;f r/ Or! - Le= AI AlAfl..
.
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION E,,_i'1tVP ~/l'j:. -!;..lIVffOI11CC.5
PARCEL 10 # 03 ~)~-J.-I-~ -00006 -6130
(OBTAIN FROM PROPERTY , TAX NOTICE)
WORK PROPSED: JdNEW CONSTRUCTION
OSIGN
PROPOSED USE: OSGL FAMILY DWELLING
o COMMERCIAL
o ADDITION
o ALTERATION
o REPAIR
o INSTALL
o MOVE
. 'rid '\ow,'J>j o.-nE-S
PMUL'U PM1IL y.
o DEMOLISH
o INDUSTRIAL
0# OF UNITS
o SWIMMING POOL
o MOBILE HOM
o OTHER
c:J RESTAURANT & HEALTH DEPARTMENT AP~ROVAL
DESCRIPT~OF WORK -'0 (;.J,V!tomE!
BUI~~ SIZE / 3CJ~ 5' )( 03..3 r
SQUARE FOOTAGE
/ S; f"Zf (p
.
I
HEIGHT .;J /
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
PERMITS REQUESTED
&Cl BUILDING
o ELECTRICAL
o PLUMBING
o MECHANICAL
$ 310 7/ f'51f 00
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
~ Progress Energy 0
W.R.E.C.
o GAS
o ROOFING
o SPECIALTY
7Q7".yL- 4u- 10 VII/ITS
VALUATION OF'MECHANCIAL INSTALLATION
o OTHER
$ 361600
TYPE OF CONSTRUCTION: OJ BLOCK
o FRAME
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
IS PROJECT IN FLOOD ZONE AREAO YES 0 NO
BUILDER
COMPANY tt S 1/ ()m~ a,~ - LEAJ/V'" IL
STATE CERT OR REGIST # CB C 1;( 5 ~ <;;) Ie
******************************************************************
(
ELECTRICI~ ~ COMPANY .::T/3 C CU;=c-,,c/ G b I' /ri;Hj"'9
SIGNATURE .......:~.~.............::~::.~:::.::.::::::.:..~~.:~:: I B 8 b
PLUMBER
COMPANY Ili<,rl/ lilt. S'c.-II t...F P7~ ~
STATE CERT OR REGIST # {:-rC 0 i.J / ? ~ /
i
. \
SIGNATURE
f *~*********~*********::*******************************************
MECHANICAL <9"'-;'/:' / _ ~ COMPANY A S-rEjO;::'llV~ SrOU&
SIGNATURE ~~--t~~ STATE CERT OR REGIST # CI'1COSOt.//O
/' '
*****************************************************************
OTHER
r<oo~/~
SIGNATURE /.--:~. . .. .. . ·
p/'/
-
COMPANY C. S-ret<1-./N6- t '
STATE CERT' OR REGIST # CCC05199/
A. NOTI~E OF DEED R~~TK~~T~UN~
The undersigned understands that this permit may be subject to "deed restrictions" which
may be more restrictive than city regulatiohs. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contr~Ftors to undertake work, they may be requi~ed
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-780-0020.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign po~tions of the "Contractor Sections" of this ~pplication for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, .AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law _ Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs, If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the information in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development,
Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be performed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies inolude but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*Army Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer register~d in the State of Florida prior to permit
issuance.
A permit issued shall ,be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for ~a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee oharge of $15.00. The extension shall be requested
in writing to'the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER
$2,500 IN VAL} D ~T NEED TO RECORD AND POST A "NOTICE O~COMJ:1E,N:E~ENTII.
~ ~"~.'{4" ,// /}>.
/ '1(1 L------
. / t
SIG~TURE: CONTRACTOR
SIGNAT
,
acknowledgement
STATE OF FLORIDA
COUNTY OF lIiLL.511o l?.ou6;(
The foregoing instrument was acknowledged
Before me this /2:111 day of /!PJ2.IL. , 20 C>6
by . EL/S5-? 1'-1. 110 '-LG<I'/,J
(name of person acknowledged)
~ho is personally known to me, or
Owho has produced
(type of identification)
~n~ho Od1d ~id n:;J jake an oath
~~~/~-~
Signature of person taking acknowledgment
STATE OF FLORIDA
COUNTY OF . H/I-L.St3tDIZOc1Ctl
The foregoing instrument was acknowledged
Before me this Iz;rH day of "IfJ4.1 f- , 2~'
by cu$5/1 "'1. HCL.L/FtZ14'"'-.J
(name of person acknowledged)
~who is personally known to me, or
of identification)
t ke an oath.
Name
tYP.~:1~lltuDr.i.nt~deQ;J; .itM\ped
~9.:~-i;."'f~ cllzaD Itn MUllinS
~~.~J:1 Co~mission # 00527014
"'~""'~ Expires March 9, 2010
, ,Waf.' Bonde<! Troy Fa,n .,n.o,*neo, 'ne 800,385.7019
Name
t~au~ n.rJ.nt~d ot. stamped
,,~l\':...~ -t:llzaDetfi Mullins
g:[ :&'i~ 'Commission # 00527014
~~if.""'~': Expires March 9, 2010
,If.f,\ Bondod Troy Fo'" ,'nsurance, Inc 800-385,7019
u.s. Homes
Eiland Park Town Homes
Siesta Key Model Bldg 2 #3 #5694
SQ. FEET PRICE
MAIN OR LIVING: 1,663 $ 50.00
OTHER AREA UNDER ROOF: $ 50.00
OTHER: $ -
VALUATION $ 83,150.00
FEE SHEET $ 416.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 684.00
CREDIT: $ -
BUILDING LESS CREDIT: $ 684.00
ELECTRICAL: $ 104.65
PLUMBING: $ 103.00
MECHANICAL: $ 73.27
SUB-TOTAL $ 964.92
RADON: $ 16.63
TOTAL $ 981.55
SEWER: $ 1,616.00
WATER: $ 419.00
IRRIGATION: $ -
TOTAL: $ 2,035.00
WATER METER:I $
IRRIGATION METER $
180~00 I
FIRE DEPARTMENT FEES
PLANS TOATL: $ 62.18
INSPECTION TOTAL: $ 13.50
PERMIT TOTAL
TOTAL: $ 75.68
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $
3,825.58 I
769.56 ~
PARK IMPACT FEESI $
SIF'S: $ 1,555.00
100.0% $ 1,555.00
1.0% $ 15.55
TOTAL: $ 1,570.55
TI F'S: $ 1,588.00
99% $ 1,572.12
1% $ 15.88
TOTAL: $
7,753.69 I
---~~----_.~----
'1
USHOME
\ I eli/illY (()mlJ(tll~
May 23,2006
City of Zephyrhills
5335 8th Street
Zephyrhills, FL.33542
Re: 15l30-52-Z002
To Whom It May Concern,
Please revise the following permit per the engineered letter.
Thank You.
Permit # 5692,5693,5694,5695,5696,5697,5698,5699,5700 and 5701
Elizabeth Mullins
Permit Coordinator
US Home Corporation
Tampa City Group purchasing
-
-
600 N. Westshore Blvd., Suite 600, Tampa, FL 33609. Telephone: 813-769-5277 . Fax: 813-769-5278. www.ushometampabay.com
.....--
"""""""
DE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
E-mail: dengine1@danscoengineering.com
CA 25948
May 10, 2006
Elissa Holleran
US Home Central Florida Division
600 N. Westshore Blvd., Suite 500
Tampa, FL 33609
RE: City of Zephyrhills Revisions
Eiland Park 10 Unit Townhomes
15130-52-Z002, Building 2
DE # 260250
Dear Mrs. Holleran:
Pursuant to your request, we have revised the plans as listed below:
. All elevation trim/banding to be cut/scored, decorative finish; please refer to the attached
sheets 3 and 4 for updated information.
. Added off ridge vents; please refer to the attached sheets 3 and 4 for updated
information.
Our review is limited to the items indicated in the above-referenced project. Further, it is the
client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions change
from the time of our review.
As always, please feel free to contact us if you have any further questions or if you should
need additional information.
Sincerely,
DANSCQ ENGINEERING, LLC
~.SS CZ/L
Thuy H. Huynh, P.E.
Fla. Reg. No. 60122
Th/md
H:\Clerical Files\Documents\Letters\US Home\2005 Job Files\260250- Revisions.doc
r~
o
o
~
(]
()
(1
(1
o
(i
.{j
E3
II
PERFORMANCE BUSINESS PRODUCTS, INC. 813-71G-8008 FAX 813-71l1-7Il111
CITY OF ZEPHYRHILLS
ZEPHYRHILLS, FLORIDA
6- j I ') ~
WATER ACCl. NO.
q /2510<0
;-.JZ';. i
DATE " ",!l \( .,
OWNERI
RENTER l.A 5 \-tr-/'V'V"""\o ~
MAILING
;r--......,--_
SERVICE ADDRESS 3'7 J:;~'i AA-r~, 'l'"""\ Rc& - t3lriq a - tt:r3
D [iJ/"WATER
SHUT OFF SERVICE
~ D SEWER
. '\:\.. '-: TURN ON SERVICE
g-- D GARBAGE
INSTALL. METER
D U3'1N CITY
READ METER
D D OUT CITY
CHECK METER
-L No. OF UNITS
OTHER D
_ DEPOSIT AMOUNT
3/4 W. ~
_ AMOUNT LAST BILL
?~~+ ~9y
_ DATE
_ MISC. CHARGE
WORK COMPLETED BY
& DATE COMPlETED
ORDER TAKEN BY
Retain white form in offICe at all times.
Send pink & yellow forms to Water Service Dept.
Water Service Dept. to sign yellow form & retum to office.
.. .
~=~
Kimley-Horn
and Associates, Inc.
September 25, 2006
.
5344 Ninth Street
Zephyrhills, Florida
33542
Mr. Bill Burgess
Building Official
City of Zephyrhills
5335 8th Street
Zephyrhills, Florida 33540
Re: Eiland Park Townhomes - Lots 11- 20
6LDb~
6eoC{ a - 5'701
sC>l[~ LOC.<=rlz2&
1('1 5loq~
Dear Mr. Burgess:
I have reviewed the As-Built Surveys ofthe lot grading for the above subject lots
and find them in substantial conformance with the Lot Grading Plan previously
approved by the City.
The project is located east of Massey Road and south of Eiland Boulevard. At
this time the plat has not been recorded and addresses have not been assigned.
If you have any questions, please do not hesitate to contact me at (813) 788-0400.
Sincerely,
KIMLEY-HORN AND ASSOCIATES, INe.
CLC:bas
Attachment
cc: Lennar Homes, Inc.
H:\049791002 - Lennar Eiland Park\Lot Grade Letters - COZ\092506 Lots 11-20.doc
.
TEL 813 788 0400
FAX 813 782 4978
i.',
i !.,.,:,'
"-\.Jl
\\,';i
, ", J \ .. I I I .. I: "
i i I
:.C-ti....;j. \") "'r
r', .
(.'.:
'r;J'f{:\;
1 'd._ -;: :;[..1fF!"
';;, ,I
",') :.:.:! <> _." 11:.
f"'j::.~.IT':;'^'
.,) i
.,r ;;:. "j
i"')" iC.;:..J(')
.!.'.:
'\1: .
I:'
"'Y" "" ,", .....
, ~ i-~'I 'J' !
o 'Z ' (\
~~i'ij!1i
1 I,ll'
I ; ii'
( C [) C;'
- -- -.-- - --.- - --.-. - - ---
'!,: "
);'. ';, _!!
)"
\ ".!'
_,1\..
.j.
i'
.,[ d
: :1 ( j
:>~: ,:;: ;.;
i.'.i (\' ',' \.
) ~ i~
\",
I'. <
:'1
Jih' l, i-<
9\[anc~ O!F COMM~9\[C~M~9tI
Notice is hereby given that the undersigned will commence (recommence) to
~~:~~ ;~~rr~~I,Ot:~~t~eScribed real property, situated in Pasco 1111I11111111111I11111111I11111111111I111I111I11111111111111
2006205791
a)
LOT# -----D.
Eiland Park
}al~'~
Rcpl:1040194
DS: 0.00
10/10/06 --
JED PITTMAN, PASCO COUNTY CLERK
10/10/06 02: 471!:' 1 it. \.
OR BK 7210 PG I'll
Rec: 10.00
IT: 0.00
__Dpty Clerk
Zephyrhills, FL 33540
b) Said improvements shall consist of: Multi-Family Residence
c) The name and address of the owner of said real property is:
U.S. Home Corporation Central Florida Division
600 N. Westshore Blvd., Suite 600
Tampa, FL 33609
d) The name and address of the contractor is:
Same as above
e) The name and address of the surety on the payment bond under Section 713.23 FS is:
Not Applicable/ Same as above
The amount of such bond is $ N/ A
f) The name and address of the person upon whom notices or other documents may be served is:
Not Applicable
g)
The name and address of the person designated in addition to the undersigned, to receive a copy of
the lienors notice as provided in Section 713.06 (2b) FS. is:
h)
notice.
Commencement of said improvement shall be within thirty days from date of recording this
Dated this 4th
day of October
,2006
Prepared By: Kimberly Daugette
US Home Corporation
R 600 N. Westshore Blvd.
Suite 500
Tampa, FL 33609
Owner
Authorized
Mich I earns Agent
Who is personally known to me,
Sworn and subscribed before me this 4 day of
October,2006
4-<1 tJtl OJ 11 Y1 1fJtL1&tI
Notary Public:
..011'../';""1
.:'~A"""l:~,
:..:' .~.:.
: . . :
~~... "'JJ
~""". -.~.."
.,.f"cff.:w........
KIMBERLY KAY DAUGElTE
MY COMMISSION # DO 458541
EXPIRES: September 10, 2009
BonaM Thru Notary Public Underwmers
DE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
E-mail: dengine1@danscoengineering.com
CA 25948
October 18, 2006
Mr. Shawn Reed
US Home Central Florida Division
600 N. Westshore Blvd., Suite 500
Tampa, FL 33609-1140
RE: Eiland Park 10 Unit Townhomes
15130-52-Z025, Building 25
Permit No.: 5692 to 5701
DE# 260251
Dear Mr. Reed:
Pursuant to your request, we conducted a limited structural review of the above-
referenced project. Specifically, we reviewed the Universal Forest Products truss
layout.
Our review was conducted using the Florida Building Code (2004 Edition). Please refer
to the attached sheets: SK1 to SK4 for revised layouts and uplift schedule.
Our review is limited to the items indicated in the above-referenced project. Further, it is
the client's responsibility to contact DANSCO Engineering, LLC, if as-built conditions
change from the time of our review.
As always, please feel free to contact us if you have any further questions or if you
should need additional information.
Sincerely,
DANSCO ENGINEERING, LLC
~d!fW
Cassidy Williams
Project Manager
J)~ ~ L
Thuy H. Huynh, P.E.
Fla. Reg. No. 60122
cw/thh/lm
H:\Clerical Files\Documents\Letters\US Home\2006 Job Files\260251 (BLDG 25) UFP layout.doc
SUBJECT: US HOME, Eiland Park 10 UNIT DE#.
DANSCO 15130-52-Z025, Bldg 25 260251
DE ENGINEERING, LLC Permit # 5692 to 5701
CA 25948 Designed by: Date: Checked by.- Date:
CW 10/18/06 SK 1/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
-, , . , , , , , _M
-, , , a_ u , , .-,
.., ..,
I - .... -.. ..- ". ,
I~ ... .... ".. ., .. ~,
I
.... -- a_ a. a. _. 1
.- "M .... "..
IW .... -- -... -. -.. _. I .
-...= ,
.... .,m ..- .... , ROW 1- ..
a~ - ~ 10
-. - "
.,.. _'-4 r- I... '-I '., ... I .... II
I - _M I... a.
I -. Fr~r~ _N
Gl - tt-'!!7. 1/'1'-'1"'-1 FGI
I IT'
~ u. r I :Di~ ~ t"1III-"1h "i'
., FG2 [If FG2
L. I
.... ... I 1 .... .-' ! ...
u, II - .... RJI - II
.- .... ... t -
-i""i/ = = "")
.....~ -- ... 'IG .- ~
~. I .... 'IG ~ ~. ...
.. .. BIW ~.. , ... Fa .- .- ....r BMS .-l
~.. "" ... 'LA ..... ..n
.. .... - .- -. .-
... .... IUI fill PLII ,
.., "" - fll' 'l2 .- I .., ..
.., I I .. .... -.. . ." .,. Ii I I
" . _.
.., 1111
ST. CROIX
ST. CROIX
MARTIMQm MARTllaQm
SIESTA KEY MARTINIQm MARTINIQm SIESTA KEY ST. CROIX
ST. CROIX
FLOOR FRAMING PLAN
(NTS)
D SAMUEL A GREENBERG, P.E. # 34245
'Q:>THUY H. HUYNH, P.E. # 60122
D IRWIN J. BENSON, P.E. # 49758
. PLEASE REFER TO lHE ORIGINAL SIGNED AND
SEALED CONSlRUCTION DOCUMJ!lIfIS FOR
FUR.'IHER INFORMATION NOTSHOWN
*10 lHEBESTOFIBEENGINEJ;XS KNOWLEDGE
AND BELIEF, lHE SlRUC'IURAL PLANS AND
SPE:::IF1CA'DONS COMPLY wrm lHEFLORIDA
RESIDENTIAL CODE, SE:::TION R301 FOR 119.9
MPH 3 SEC. GUST EXPOSURE "B" ENCWSFD
WIND ZONE(2004 FDI'DON, INCLUDING 200S
SUPPLEMFN1).
* IBIS DRAWING AND DESIGN IS VALID FOR 12
~Q~~ A~ ~!'~~~.!~.!'!:ID AND_~EALED-,--
* SIGNED AND SEALED FOR lHESlRUClURAL
PARTOFlHIS DRAWING ONLY.
~< tLL
OCT i 8 200E
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813) 645-9698
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130-52-Z025, Bldg 25 260251
DE ENGINEERING, LLC Permit # 5792 to 5701
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 2/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
-_v__,.._____~ ~,__~~,_.~~.._~#A
2nd FLOOR FRAMING SIMPSON CONNECfORS SCHEDULE
TRUSS JOINT GRAVITY CONNECTION STY CONN. FASTENERS~=--
~.
TYPE I LOCATION (LBS) CAPACITY PER CONN.
'THE FOLLOWING CONNECTIONS ARE FOR THE LEFT HAND UNITS. FOR RIGHT HAND UNITS, REVERSE
: CONNECTIONS FROM LEFT TO RIGHT AND VICE VERSA
8M3 LEFT 720 4. 15d NAILS
RIGHT 1379 HUSC410 1 1708 16-1Dd
FRONT 448 HGUS46 1 2899 28-10d
BM4 INTERIOR 2741 4 - 16d NAILS
I REAR 1497 WMI46 1 33BO 2-10d x 1 1/2" &2-114" J(' 3/4"
T1TEN SCREWS
- FG1 LEFT 905 4 - 16d NAILS
, . RIGHT 57.11 HU21 0-2 1 20.118 2B-1Dd
;
. LEFT 8SB HUC21D-2 1 2048 28-lOd
FG1A RIGHT B25 HU21O-2 1 2048 28-lOd
FG2 LEFT 986 HU21 0-2 1 2048 2B-10d
RIGHT 828 HUC210-2 1 2048 28-lOd
;
FG2A LEFT 926 HU21O-2 1 2D48 28-lOd
. RIGHT 1012 HUC21 0-2 , 2048 28-lOd
: , ;
i"Double connectors to placed diagonally to each other.
!.::QQ..Q9.t.gr;y.~-lJ..~1I.~.!.b!:9_l:I9b..!b..E?J~!l~rs.J~!~~-9Q-tb~.QPP9.~jt~_s.i9E?.9tJtl~.!r~~~u~blf.b..~9..l.llg___. .......m........_.._..
iforce the plate off the tru~s. i : ..L_' ___,.__:
...... Mounted verticall~. I I . I. .
'..M..__..__._..____._....._.._._____...__.. _M..____...._.___._____._._...._._____.._..........__________....__.........___._..__....._~.____._..._......__.____...__......._...___._...._..
2nd FLOOR FRAMING SIMPSON CONNECTORS SCHEDULE
o SAMUEL A GREENBERG, P.E. # 34245
!SbTHUY H. HUYNH, P.E. # 60122
tJ IRWIN J. BENSON, P.E. # 49758
'PLEASEREF.ER'IO 'IHEORIGINALSIGNED AND
SFALED CONSlRUCTION DOCUMlNlS FOR
FURUIERINFORMATION NOTSHOWJIi
'10 lHEBESTOFlHEENGINEERS KNOWLEDGE
AND BELIEF, lHESlRUCTIlRALPLANS AND
SPECIFICATIONS COMPLYWllH 'IHEFLORlDA -!::X!a.,L
RESIDEN'IIAL CODE:, SECTION R301 FOR 119.9
MPH 3 SEC. GUSTEKPOSURE "B" FNCWSED
WIND ZONE (2004 EDmON, INCLUDING 2005 i) .
SUPP~. OCT .18 2006
. lHIS DRAWING AND DESIGN IS VALID FOR 12
M.Q~:J:!!~~ ~DA'lESI~~ ~ S~.~:._...
, SIGNED AND SEALED FOR 'IHESlRUCTIlRAL
PARTOFlHIS DRAWING ONLY.
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813) 645-9698
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130-52-Z025, Bldg 25 260251
DE ENGINEERING, LLC Permit # 5692 to 5701
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 3/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
I o' II n
~ ~ I l!~ ~ ~
, , I
I I I u
".. , , , . w..
- " I I f;!1 I / -
, , I I , , ;I
I :cIa I I I /
" &1. I , .
" I I I I 7
'-, I , /
I I I
I\.., , , . ,
I I I I
, / I
-~ ! r'\ !
- - - v , " - - - - -
I I
/' , , "
/ I I r-.:
I =r~=I~ I =~~ I :r.l'C.i\ "
/' 1",:1'''w )c 1'\ I I~ "'ll!'..... i'\ ""
I I ,
r'\ I "- I ~
, ~I\.., I "- , ,/
t l !J I ,/ r-
, Ir
" , \ /
If)( K G~ r-
..... ~ ~ III ......,/ ,
.
f 7T1 ~ I II 711 ~ J
~
:~~..I i ~=t:I.tJ ~ ...._t T
....".
ST. CROIX ~TImQ~ ~TImQ~
SIESTA KEY ~TImQ~ ~TImQ~ SIESTA KEY ST. CROIX
ST. CROIX ST. CROIX
ROOF FRAMING PLAN
(NTS)
o SAMUELA GREENBERG, P.E. # 34245
'liI' THUY H. HUYNH, P.E. # 60122
I '0 IRWIN J. BENSON, P.E. # 49758
"PLFASEREF.ER TO lHEORlGINALSIGNl!D AND
SFALID CONSlRUCnONDOCUMENlS FOR
FURlHER INFORMAnON NOT SHOWN
"TO lHEBESTOFlHEENGINEERS KNOWLEDGE
AND BELIEF, lHE SlRUC'IURAL PLANS AND ~tLL
SPECIFlCAnONS COMPLYWrm nIEFLORIDA
IUSIDFN'llALCODE, SECnON roO! FOR 119.9
MPH 3 SEC. GUST EXPOSURE "B" ENCLOSED
WIND ZONE(2004 EDmON, INCLUDING 2005
SUPPLIiMEN1). OCT 1 8 2006
" nns DRAWING AND DESIGN IS VALID FO R 12
~ON1BS ~_JHEDA1ESIGNED AND SFALED. --
"SIGNED AND SFALED FOR lHESlRUC'IURAL
PARTOFlHIS DRAWING ONLY.
P.O. Box 3400
Apollo Beach, Florida
(813) 645-0166
Fax (813)-645-9698
SUBJECT: US HOME, Eiland Park 10 UNIT DE#:
DANSCO 15130-52-2025, Bldg 25 260251
DE ENGINEERING, LLC Permit # 5692 to 5701
CA 25948 Designed by: Date: Checked by: Date:
CW 10/18/06 SK 4/4
Problem: Engineering to revise truss layout from schematic to Universal Forest
Products truss layouts.
Solution: See sheet SK1 for floor framing plan, SK2 for floor connection schedule,
SK3 for roof framing plan and SK4 for uplift schedule.
-~",.... r__ ---.-....- ---. -~~- _.-.~. -..-.- --- ---.
i UPLIFT SCHEDULE
UPLIFT VALUES SHOWN ARE CALCULATED BASED ON CONSERVATIVE APPROACH AND CAN BE
DIFFERENT FROM TRUSS MANUFACTURER'S VALUES
TRUSS JOINT UPLIFT CONNECTION QTY CONN. F ASTENERS*"
..........-....-....-.-- _....._..0...__....______ --..........---.... .....--.....--.--.....--..-........... --..---..-....- -..----..----.....-----.-.............-......
TYPE LOCATION (LBS) CAPACITY PER CONN.
THE FOLLOWING CONNECTIONS ARE FOR THE LEFT HAND UNITS. FOR RIGHT HAND UNITS, REVERSE
iCONNECTIONS FROM LEFT TO RIGHT AND VICE VERSA
i E2A FRONT 120S HTS20 1 1450 24-1Dd x 1 112"
REAR 1134 HHETA2D 1 2235 1D-1Dd x 1112"
LEFT 2975 MGT(l) 1 3140 22-1Od x 1 112" & 518" EMBED.
INTO SIMPSON SET EPOXY
G1 USP KLEG HANGER (SEE DETAlLAlS2.2 ON ORIGINAL S&S FOR
RIGHT 2975 UPLIFT CONNECTION)
I
[NOTE: ALL OTHER TRUSS BRG. CONNECTIONS ARE SIMPSON HHETA20 FOR
'MASONRY; SIMPSON H10 FOR FRAME; & HUS26 FOR HUNG TRUSSES ON GIRDERS
:Jdt\{~1=j)S OTti~8.JNlSE ~QJEQ:-----__m_____'m____m_..__.______________________,__
'THESE TRUSS UPLIFT VALUES ARE LESS THAN CONNECTION CAP A CITY.
MASONRY HHETA2D 1 2235 1O-10dx1 112"
,
.. TIMBER H10 1 B5D 1S-8d )( 1 112"
,
, HUNG HUS26 1 1317 2D-1Od
i:Qp-L1.Q!~sg.Dn~f!PI~JQ1lJE!~~st9.iElg9n~_tQ_~acb9Jb~LL___________._____.___._____.____ ...-..-.-....-..----
~~~~~~==1=i~=~+===~~==~=~-=-~
i(1) Connecti on_~.!f:i.~ exteci or w~L_________. UPLTFTSCHEDULE ----...-.---,
a SAMUEL A GREENBERG, P.E # 34245 REFER TO ORIGINAL S&S FOR INFO. NOT SHOWN
Z!/J THUY H. HUYNH, P.E # 60122
La IRWIN J. BENSON, P.E # 49758
o PLFASEREF.ER 10 TIlEORIGINALSIGNIID AND
SEALED CO NS1RUCTION DOCUMIiN1S FOR
FUR1HERINFORMATION NOT SHOWN
ow 'lHEBFSTOF1HEliNGlNEERS KNOWUDGE
AND BELIEF, TIlESlRUCTIlRALPLANS AND ~),J ((_ ~
SPECIFICATIONS COMPLY WITH 1HEFLORIDA
RESlDliNTIALCODF, SECTION R301 FOR 119,9
MPB 3 SEC. GUSTJOO>OSURE "B" liNCWSED DC? I 8 2006
WIND ZONE (2004 EDmON, INCLUDING 2005
SUPP~.
o 1HIS DRAWING AND DFSIGN IS VALID FOR 12
MO~S A!1ER ~!J!.~ AND.-s.~,-_._
o SIGNED AND SEALED FOR 1HES1RUCTIlRAL
PARTOF1HIS DRAWING ONLY.
P.O. Box 3400
Apollo Beach, Florida
(81 3) 645-0166
Fax (813) 645-9698