HomeMy WebLinkAbout06-6208
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
6208
Permit Number:
Permit Type:
Class of Work:
Proposed Use:
Square Feet:
Est. Value:
Improv. Cost: 2,275.00
Date Issued: 11/02/2006
Total Fees: 102.50
Amount Paid: 102.50
Date Paid: 11/02/2006
Work Desc: INSTALL MONUMENT SIGN
208
SIGN
FREE STANDING SIGN
COMMERCIAL
Address: 6900 GALL BLVD
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot{s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number: 02-26-21-0010-00900-0011
BORRELL ELECTRIC CO
(: ()c~Lc.d
L\-lo--0"7
t~
REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
NO OCCUPANCY BEFORE C.O.
~Ic /~ ~~
CONT CTOR SIGNATURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020
City of Zephyrhills Permit Application
Building Department
Fax-813-780-0021
31 - ''l-rS PA\J 0
7f'3-b7~\.
I
I
I
8/Ld. I LOU I I
I PARCELlDtI OZ. 2"- 21'" OOID-00900-a?J~
D ADD/ALT ~2;~:TAll::;"~EMOL1SH 0 t,D $ \ 6:1'
D REPAIR ,~ IJ)
PROPOSED USE D COMM D OTHER I I
TYPE OF CONSTRUCTlON D BLOCK D FRAME D STEEL D OTHER c= I
DESCRIPTION OF WORK II N Sl1r u.... IY\ D f\J V tvLEN"\ '9.l6 N I
I sa FOOTAGE I ~ S I HEIGHT lJJ ~ 0 ' I
1$ 27-75;00 I
D ELECTRICAL 1$ I
D PLUMBING 1$ I
D MECHANICAL 1$ I
D GAS D ROOFING D
FINISHED FLOOR ELEVATIONS I I
DlIt. Received
Own.r Phone Number g l3
Own.r Phon. Number I
Own.r Phon. Number I
Own....N.me MQV\\At,.1 Rose
Own.... Add..... I ~ q 00 c;, cd l B\"~.
Fee Slmpl. TltI.holclar Nama I
JOB ADDRESS
Fee Simple Tltleholclar Add.... I
1lt>'100 €Jq 1/
I
SUBDIVISION
WORK PROPOSED
BUILDING SIZE
D
BUILDING
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
D
PROGRESS ENERGY
D
WREC
VALUATION OF MECHANICAL INSTALLATION
SPECIALTY D
FLOOD ZONE AREA
OTHER
DYES
DNO
Add.....
PLUMBER
SIGNATURE
COMPANY
REGISTERED
~(~ ::~~Tcot~I\~G7.5~
License # ~A\\ g\ 2- I
~fIi't/~~"'~ I ~ "c.
License # lEe /3 Of) ~ 9 7 tP I ~ -'
I
I
I
I
I
I
Y/ N
FEE CURRENT
~
BUlL-CEil
SIGNATURE
ELECTRICIAN
SIGNATURE
Add.....
Add.....
MECHANICAL I
SIGNATURE
Add..... I
~~N~~RE I
Add..... I
License #
COMPANV
REGISTERED
V/ N
FEE CURRENT
~
License #
COMPANV
REGISTERED
V/ N
FEE CURRENT
~
License #
RESIDENTIAL
Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Sanitary Facilities & 1 dumpster
Attach (3) sets of Building Plans; (1) set of Energy Forms.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Sanrtary Facilrties & 1 dumpster
All commercial requirements must meet compliance.
Attach (2) sets of Engineerad Plans.
---PROPERTY SURVEY required for all NEW construction
COMMERCIAL
SIGN PERMIT
DIrections:
Fill out application completely
Owner & Contractor sign back of application, notarized
If over $2500, . Notlc. of Commencement I. required. (AlC upgrades over $5000)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTlNG (Front of Application Only)
Reroofs Sewers Service Upgrades NC Fences (Plot/Survey/Footage)
Drlv.way.-Not over Counter If on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNUCENSED CONTRACTORS AND CONTRACTOR RESPONSIBIUTlES: If the owner has hired a contractor or
contractors to undertake worn, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended worn, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not proper1y licensed and is not entitled to permitting privileges in Pasco
County .
TRANSPORTATION IMPACTIUTlLITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION UEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of worn is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law--Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all worn
will be done in compliance with all applicable laws regulating construction, zoning and land development Application is
hereby made to obtain a permit to do worn and installation as indicated. I certify that no worn or installation has
commenced prior to issuance of a permit and that all worn will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended worn, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterlWastewater Treatment
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use offill is not allowed in Flood Zone 'Y' unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical worn,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the worn and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the worn authorized by such permit is commenced within six months of permit issuance, or if worn authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the worn is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If worn ceases for ninety (90) consecutive days, the job is considered abandoned.
CONTRACTOR ~ '. -+-.-..-.-----'"
/ b~u~~~t(3:0"f!"~0 ~mtg; befor ~t'7iJ-tE~
Who is/are personally known to me or haslhave produced
C~j)~#lttafOO"'-~
Commission No I ;L -'8 ~ 07
~ 'Mv\~ lUl Lt.-JEll
Name of Notary typed, printed or stamped
Notary Public
OWNER OR AGENT
( ~bSCribe2:;'nd sw or a "med) efor~ me this
O~ ~- () by Mn-
Whe;? is/are personally known to me or haslhave produced
~
~t~~ ~~, __,~"
Commission No. / d- - G r t) 7 .
K'~~~. \JJIL-LfT/
Name of Notary typed, printed or stamped
,,~:~ R. Mark Willett
~'f'Ji"1 A MY COMMISSION # DD262312 EXPIRES
~.~~~ December 8, 2007
"~O'r.''oi.~'' BONDED THRU TROY FAIN INSURANC~ INC.
'ft..'"
,,';.':r:~'N:ItJ, R. Mark Willett
{f' .,~: MY COMMISSION # DD262312 EXPIRES
~" . 1 December 8, 2007
.,,~ .... BONDED THRU TROYFAIN INSURANC~ INC.
""1111
...._,,_...;,;;.~..;,.;;.;..-""-'-'------..;;..,;.;:;..~~..~--
Permit A Ii' .
B' . P.P cation Review C
y. Bill Burgess omments
Date:
Address:
Type:
.
I
{ff/e S'ffI i ~
~ No Commen!s
1/-j-tJ(P
h 9gD GII-II g; ID
JA sh! / /JI1.. .
11 ~fY1e^f
S)ffn
-.
LETTER OF PERMISSION TO INSTALL SIGN
DATE \ \) \ C) li \C)U)
ADDRESS \.Q~~' G~u b~\)d Zr~'-'{'b\\\s .\L r5~~ \
AS OWNER(S) OF THE PROPERTY LISTED ABOVE, WE GRANT APPLE
SIGN & AWNING LLC PERMISSION TO INSTALL SIGN. PAUL LIMA OF
APPLE SIGN & AWNING TO ACT AS OWNERS AGENT TO OBTAIN SIGN PERMIT
OWNERS NAME MCt1\~l ~~
ADDRESS \i)C\OD Gc-u b\ud
cITYLe ~~V{\~\\\~ STATE \=-L
TEL. ~\. ~ - I~ ~-1o~6l.Q
ZIP .~ ~Sy 1_
OWNERS SIGNATURE
~~~
NrYrARY/?;~~~
DATE -- -. 4?
SEAL
,~lo.'l'~'~ Mary Judith Liner
'~t;'''.:,.(i...!, 969
€'!(/;;,.w-: Commission # 00517
;,.,.\ArI: : Expires {'/larch 6, 2010
-~ ..... .315-7019
,tf.l.1F ffi -nded Troy Fam . Insurance, Inc. SOO
'nn' -
COMP~NY: Apple Sign
tpROJECT: Rose Radiology
MEAN SIGN HEIGHT (HB)
CHECK FOOTING
Pallow = S * b
2.37 * d
Pallow = 2.5 * 3
2.37 * 4
-0
0'
,en
~
v
Architectural Services & Engineering, fnc
24710 State Road 54 EBO 7882
Lutz, FI 33559
Robert W. Wall, PE
Fla 46021
9
N
Sample Calculations
Wind Load = WL
WL = CI . WIND ksl
WL = 1.2 . 2.08
Force = .02500' 72
Force = 1.8004 kips
8' - 0"
Area 1
Zreq = Moment' 12
III . NC
Area 2
fll ,= 21.0 ksi lor Steel pipe
fh ,= 27.6 ksi for Steel pipe
III ,= 19.0 ksi for Alulllinulll
LOF = 1
Zreq = 8.102' 12
24 . 1 .
Zreq = 4.051 in3
"x .28 " ASTM A53-S/B Pipe
in3 > Zreq = 6.05 in3
Concrete approx. 1.33 cu. yds
Concrete is 3000 psi at 28 days
Wind loads - FBC 2004, ASCE 7-02
Steel - AISC-ASD Ninth Edition
SOil hearing capacity 2000 psI (2 ksf)
3 ' - 0 ..
I- -d
x 3' - ..
~I
WIND - ASCE - Exposure B
Cf WI
( sf)
FORCE
(ki s)
1.80
0.40
2.20
MOMENT
(k - ft)
8.10
12.10
Z REO
(in3)
4.05
6.05
y
(ft)
6.50
1.00
1.00
2.00
TOTALS
1.20
1.20
20.84
20.84
72.00
16.00
88.00
MOMENT AT GROUND
TOTAL FORCE
12.10 k-ft
2.200 kips
5.5 ft
* d ^ 2
+ 2.64 * HB
* 4 ^2
+ 2.64 * 5.5
b = width of footer (ft)
d = height of footer (ft)
= 5 (kips) > 2.20 (kips) is O.K.
. FcoT MDNUM-err" SlbN
lll.llM IJJATED)
I<
( II
Z-O
Apple Sign & Awning
1635 N. Dale Mabry.7
LU~7 FL 33548
>l
lI-
t-
.. _~ 1 ~_-7 ~-6736
~~:rMRI lI~o"~
. J.RAY · ULTRASOUND · __ · DEIA · CT '
~ClA~
taft
1-
"
" STea,. PI PE-
ALL SIGNS ARE BUILT TO UL SPECS
ALL SIGNS WILL BEAR UL LABEL
ALL SIGNS COMPLY TO UL 2161
@ All WIRING MUST BE IN f!J
UL fUll COMPLIANCE, WITH n c
f) N.E.C. SECTIONS 250 & 600,
f-- ~,"--{
~( tl II
"3" )(. 3" )(.. +8 DeEP
CfJr4qzere ~
" fii:'L. . Underwriters
~~~~~!!IOrllllnu
. . ELEC1RIC SIGN
N~ B[f~554915
'. 1';1\"
~
rq~JrJq
. ;-c,'~r- :-/: