Loading...
HomeMy WebLinkAbout06-6218 ". CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 6218 Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 6218 FIRE PROTECTION FIRE ALARM SYSTEM COMMERCIAL Address: 5814 8TH ST ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 11-26-21-0010-02500-0200 .~ 11/06/2006 Name: KIDS CORNER 125.00 Address: 5930 8TH ST 125.00 ZEPHYRHILLS, FL. 33542 11/06/2006 Phone: 813 782-3333 FIRE MONITORING PANEL-STROBES/SMOKE DET/PULL STATIONS . ~, /,;:\, ,1\ (~AN C\~ \ \ , ~ '-'r REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NO OCCUPANCY BEFORE C.O. iJ1~~ ~. CONTRACTOR SIGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Building Department t-aX-tlM-/tlU-UU;!l DatB Received Owner Phone Number Owner Phone Number I Owner Phone Number I OWner's Name JOB ADDRESS Owner's Address Fee Simple Titleholder Namel k, ~ I<~ ~ Fee Simple Titleholder Address I I S-f-r '-( I ~ 51 ~ sr 2 ~I'" 'r" J.., ({ s I PARCEL ID#I B D o k '$ sS- y "2- lOTN WORK PROPOSED ~ D W- NEW CONSTR INSTALL SFR BLOCK ADD/ALT REPAIR COMM // _ ;). ~ ;?- (- DO l 0 - 0"2 s-c.c Cf2- CJ"-' (OBTAINED FROM PROPERTY TAX NOTICE) SIGN D MOVE 0 DEMOLISH SUBDIVISION PROPOSED USE TYPE OF CONSTRUCTION FRAME o D o OTHER I r-=: ll1..J#\"AI I ~~ ( -:J STEEL D OTHER I P -1vV c.1/... I I DESCRIPTION OF WORK I- \,.-c. V'-t, ~ , J"", . (/....... __I. ~ tyl--&) iI, ~ . ~ l~ ~ tJ .~"t P '" ( ( :> ~ BUILDING SIZE I I ~ "7 ISQ FOOTAGE I 3 ~6 0 -t- I HEIGHT I Z 0 PI: I I . I I I . . I I ~ I t I I I I . . . ." , I I . . , I . . I . . . . : . . . I I I I . I . . . . , . . . I . . I . . . I . . I I I I . . . . . . I . . . . . . . , I . . . . . . . . . , , . I I . . . . , I . . . . I . . . . . . , . I . I . . I . I . I . . , I . . I . , I . I I . , . . . I . . D BUILDING 1$ I VALUATION OF TOTAL CONSTRUCTION D ELECTRICAL 1$ I AMP SERVICE D PROGRESS ENERGY . Nee ./ D PLUMBING 1$ I F-l ~V'l - ( , I. D MECHANICAL 1$ I VALUATION OF MECHANICAL INSTALLATION D GAS 0 ROOFING 0 SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA DYES DNo 11111'f",II..IIII.I.",IIIIIII,..".,I..IIIIIIIIIIII'"111"1.""'1111111111111"'..."'111"...11111'1111,i","""""""IIIII'I"""'I""1 D W.R.E.C. BUILDER SIGNATURE JVL~~ COMPANY REGISTERED L1censB # Y/N FEE CURRENT License # Y/N FEE CURRENT License # Y/N FEE CURRENT License # Y/ N FEE CURRENT Y/N Address ELECTRICIAN SIGNATURE COMPANY REGISTERED Address PLUMBER SIGNATURE COMPANY REGISTERED Y/N Address MECHANICAL SIGNATURE COMPANY REGISTERED Y/N Address OTHER SIGNATURE COMPANY REGISTERED Y/N Address License # i II i i 11111 i i III 1111111 i II , , 1111111111111111111111111111111 i i III i i i Iii i III i i i 1111111111 , 1111 ii' 11111111111111111111111111111 i 11111111111111111111 i RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for nBW construction, Minimum ten (10) working days after submittal date. RequirBd onsite, Construction Plans, StDrmwater Plans w/ Silt Fence Installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projBCtS COMMERCIAL Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W PBrmlt for new construction. Minimum ten (10) working days after submittal date. Required onslte, Construction Plans, Stormwater Plans w/ Silt FencB Installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projBCtS. All commBrcial requirements must meBt compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ....PROPERTY SURVEY required for ail NEW construction. II)III! 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 111111111111 1111111111111111111I111111111111111 Directions: Fill out application complBtely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (Ale upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs SBwers Service Upgrades AlC Fences (Plot/Survey/Footage) Driveways-Not over Counter If on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliancl'! with any applicable deed restrictions. . . UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or contractors to undertake work, they may be required to be licensed In accordance With state and local regulations. if the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violatioh under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the oWner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the constrUction of neW buiidings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance huinber 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportatioh Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid priorto permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction lien LaW-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to ineet standards. of all laWs regUlating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended Work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, VVetland Areas and Environmentally SensitiVe Lands, WaterlWastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads; Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. . If the fill material is to be used in Flood Zone "N in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem Wall. If fill material is to be used in any area, I certify that use of such fill will hot adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less thah one (1) acre which are elevated by fill, an engineered drainage plan is required. . If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical wor~, plumbing, signs, wells, pools, air conditioning, gas; or other installations hot specifically included in the applicatiorl. A permit issued shall be construed to be a license to proceed with the work a~d not as authori~y !o violat~, cancel, alter, or set aside any provisions of the technical codes, n?r shall.lss~ance of a permit prevent the B~II.dlng OffiCial from the~eaft~r requiring a correction of errors in plans, construction or vlolat~o~s o! any codes., Every ~ermlt Issued. shall become. Invah~ unless the work authorized by such permit is commenced Within SIX months of permit Issuance, or If work authorized. by the permit is suspended or abandoned for a period of six (6) months after the time th~ work is commenced: An extension may be requested, in writing, from the Building Official for a period not t~ exceed n1n~ty ~90) da~s and Will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the Job IS conSidered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCiNG, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) CONTRACTOR Subscribed and swom to (or affirmed) before me this by . Who Is/are personally known to me or has/have produced as Identification. OWNER OR AGENT Subscribed and swom to (or affirmed) before me this by Who Is/are personally known to me or haslhave produced as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed. printed or stamped Name of Notary typed. printed Dr stamped Fire Chief Robert Hartwig ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813) 780-0041 Fax (813) 780-0044 Occupancy No.: Plan No.: Business Name: BusinessAddress: Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES ~ Site Plan N/C Building Plans .04 sf Revision .06 sf FIRE SERVICE USER FEES STANDPIPE SYSTEM D Per Riser $25 SPRINKLER SYSTEMS QO-25Heads ~ ~26 plus Heads ~ FIRE PUMP D Per Pump $100 FIRE ALARM SYSTEM D 0 - 25 Devices $30 D 26 plus Devices $60 SUPPRESSION SYSTEMS ~ Wet $35 Dry $35 C02 $35 Other $35 GREASENENTILATION D Hood/Ducts $35 INSPECTION FEES Annual N/C 1 st Re-inspection $25 2nd Re-inspection $50 3rd Re-inspection $125 4th Re-inspection $250 5th Re-Inspection $500 Construction $15 Commercial $25 SPRINKLER SYSTEMS Hydro Undergrounds $45 Hydrostatic System $45 Wet Acceptance $30 Dry Acceptance $45 Hydrant Flow $25 Hood / Booth $30 Grease Duct $15 FIRE ALARM S~ ~ System Acceptance ~ o Recall Acceptance $50 OTHER Fire Wall/Smoke Wall $15 LP Gas $25 Natural Gas $25 Fuel Tanks $25 Tent $15 ~lll@t. ~ Billing Phone No.: ~.- Billing Fax No.: Contact: A-1 ~- PERMIT FEE FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $25 5th Alarm $50 6th Alarm $75 7th Alarm $100 8th Alarm $150 9th Alarm $200 10th Alarm $250 Non Compliance $150 "Affidavit of Service/Repair" SPRINKLER SYSTEMS D Automatic $15 FIRE PUMP D Fire Pump $15 td1 FIRE ALARM SYSTEM Lf'J. Detection @ OTHER ~ LP Gas Natural Gas Fire Works Fuel Tanks $45 $45 $25 $45 GREASENENTILATION D HoodlDucts $15 t)O D KltChensuppr~eSSlon $15 / FALSE ALARM PLANS TOTAL I fdJ r INSPECTION TOTAd PERMIT TOTAL TOTAL I I /j..~ ~~~ ~ 11 Comm,"ts. uu, :k ~.;-- ~_- _' ~: _ -_ ;~_ . . <f--=-.s.. Date: 1//rJ;r g"71tnt/d~ .nee Inspector: NOTICE OF COMMENCEMENT State of r-./ ""'" ,"'..... Co unty 0 f PI}:, C<) THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel No. II. 2. (. . ~ ( - Do [0- 0 "l...S' 00' ";a.. dO (Legal description of the property and street address if available) 2. General Description of Improvement 3. Owner Information: Name C ~fr..(y rv, /)L..:.~ Address S~/'1 ~/C1. Sr City 2- ~4 h,.-t.., [(c. Interest in Property: O<:......J.v ~.""1 State~L $'$ .s-y~ Name of Fee Simple Titleholder: (If other than owner) Address 4. Contractor: Name -.Sl\/IJ' ~)j_ ~ CL~('-I 4 Address33'so UL...I'1-1Y-<2-rv.-J fl-A s~',r 17 City CL~~~ City State 5. Surety: Name State {'::L 3 ~/{ (.. Address City Slate Amount of Bond: $ 6. Lender: Name Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (l ) (a) (7), Florida Statutes: City State Name City State Address 8. In addition to himself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes. I. Expiration date of Notice of Commencement (the expiration date is I year from the date of recording unless a different date is specified.) ignature of Owner: L O-H:/{'iU"}tCi , Vf! ()( 0 LIUJ worn to and subscribed before me this ~ day of 1"\.) () " ~ ~ _, 20~. otary Publi . HotIwy Public - si... d Fbfdt an . 0 Calnmiaaion , DO 511506 ........, ~ ~ AIM. :930530481 A 1 YEAR OLD CLASSROOM ~ F -~ -,,~ [J LAV ~ ~ 2 YEAR OLD CLASSROOM F' ~ 3 YEAR OLD CLASSROOM F ~ F Ir--- I~ I \ F ~ t-----------------I RECEPTION COUNTER ---.------- OFFICE KEYED NOTE,S 0) NEW FIRE ALARM CONTROl PANEL 'MTH (2) UNE DIALER. PROVIDE DEDICATED 20 AMP CIRCUIT fROM AVAILABLE BREAKER IN PANEl. COORDINATE PHONE SERVICE 'MTH OWNER. CD VERIFY REQUIRED LOCA TlON OF FIRE ALARM REMOTE ANNUNCIATOR 'MTH THE AUTHORITY HAVING JURISDICTlON. o HIGH TEMP. FIXED HEAT DETECTOR IN ATTlC SPACE. F ~ { r" r L, ~ I ',,- I . L ::~ L:V 8 LAV IJ {1 LAV c----~ {1 LAV c-=: ~) F ~-- ---------- F l::=__ MRS. CATHY'S OFFICE ~- F \- \",~-- ~: ~ ~ KITCHEN '1D4 ~ NOTE: THERE IS NO COOKING EQUIPMENT IN THIS KITCHEN. SCHOOL AGE ROOM / ~ F CORRIDOR ~ ~ ~ 4 YEAR OLD CLASSROOM COMMONS AREA ID4 ~ ~--- Building shall comply with the applicable codes of Florida Fire Prevention Handbook NFPA & the City of Zephyrhills FLOOR PLAN - FIRE ALARM SYSTEM SCALE: 1/4" :::: 1'-0" APPROVED by Fire Marshal of Zephyrhills with comme7~.ts v7~i~ ~~ ##'~ /1 /f(t~ '~1l. . U"'~'llI"~ INSPECTION(S) REQUIRED BY ZEPHYRHILLS ED. ~ ~/lt /k~;ldfU-J6f , _J // k~')'2'/dCV/''''U-J ,,;7/ .'i- ~/II~#J. S/~.Ut 7 , &PKL. l' ~ t./,/y,cd.f ~'l~v I? c) /1 ;/~. f{" f/It/lc--~cl, ;r(tV/P! ~ ~ jf U/ll,f?.d1,"C6f if} fY<;~ Ii> Cf'C./<,-&(1< 2'\')-~O GENERAL NOTES 1. BUILDING IS NOT PROTECTED BY A FULLY SUPERVISED FIRE SPRINKLER SYSTEM. 2. ALARM SEQUENCE: UPON ACTlVATlON OF ANY FIRE ALARM INITlATlON DEVICE THE FIRE ALARM CONTROL PANEL SHALL IMMEDIATELY GO INTO GENERAL ALARM CAUSING THE FOLLOWING TO HAPPEN: A. ALL AUDIBLE AND VISUAL NOTlFlCA TlON APPLIANCES SHALL ACTlVATE. B. DACT SHALL NOTlFY OFF PREMISE MONITORING STATION OF THE GENERAL ALARM. 3. ALL COMPONENTS AND WORKMANSHIP SHALL MEET OR EXCEED THE FOLLOWING: A. NfPA 70 - NATlONAL ELECTRICAL CODE. B. NfPA 72- NATlONAL FIRE ALARM CODE. C. ANSI A1171.1-AMERICAN NATlONAL STANDARD fOR BUILDING AND FACIUTlES PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE. D. NFPA 101-UfE SAFETY CODE. E. NEC ARTlCLE 760-FIRE PROTECTIVE SIGNALING SYSTEMS. F. AMERICANS 'MTH DISABIUTlES ACT OF 1990. G. FLORIDA ACCESSIBIUTY CODE FOR BUILDING CONSTRUCTION. H. flORIDA FIRE PREVENTlON CODE. I. SYSTEM: UL LISTED. J. CONFORM TO REQUIREMENTS OF NFPA 101. K. UL USTED-UL 1076. 4. ALL FIRE ALARM HORNS SHALL HAVE A MINIMUM DB OF 87 AT 10 fEET AND SHALL NOT EXCEED 120 DB. 5. ALL FIRE ALARM STROBES SHALL HAVE A flASH RATE OF AT LEAST 1 HZ BUT NOT EXCEED 2 HZ. 6. FACP SHALL HAVE BATTERY BACK-UP FOR 24 HOURS 'MTH 5 MINUTES OF ALARM CAPABIUTIES (PER NFPA 72). 7. FIRE ALARM INITlATlON CIRCUIT CABLES SHALL BE 18GA 2 CONDUCTOR RISER RATED FIRE WIRE "HONEYWELL" FlP-R. CABLE SHALL BE USTED 'MTH UL, FPLR/CL2,C(UL) AND FT4. 8. FIRE ALARM NOTlFlCA TlON APPUANCE CIRCUIT CABLES SHALL BE 16GA 2 CONDUCTOR RISER RATED FIRE WIRE "HONEYWELL" FLP-R. CABLE SHALL BE USTED 'MTH UL, FPLR/CL2,C(UL) AND FT4. .. ... I . Ie.) 8.5 U 0 ~ x Z 13 '.6 ~lV ~ 1:1 ~ en 01O .., Ol <C> C ~I ""~ ..... 'C 1O['- ';I t1) M 8 Q) ~~ .., C .:J .- ~~ E-4~ ~~ ~ffi ~c.o '0 0 ~~ NO ~C\/ ~~ Q~ "(0 ~g .., r- ~.. .._ \1') ~~ ~ '~ sas t': C\~ -.... ~E ~. ~~ ~en ~(;) 'rl ~~ O~ ~ H -j.j , 1O. ~Z (lj~rl Zu ~&; '0 0 ;Sc.;g ~ -.;i" tw.. ~ -.., ~ I~ ~n .., ~ 0.9.~ . f;; t~ ~ ~..o Z -l:a 'rl <l);i': r- 0 HZ, ~ f!~ Q) ,~ Q) ~ C' ~ ~ 'rl ~.~ -<ll b.O~ ."" r:. ~ C'l S 0 ~U5~ ~ ~ U S H , / F F / , TYPICAL SIGNAL CIRCUIT FOR 8LOG'S. 3/4" C. TO TELEPHONE SERVICE COMM. WITH FARA F FACP FIRE ALARM RISER DIAOnAM NOT TO SCALE ~ CD PROVIDE CABLING AND ALL OTHER REQUIRED COMPONENTS AND ACCESSORIES FOR A COMPLETE INSTALLATlON. o PROVIDE CABLING AND ALL OTtiER REQUIRED COMPONENTS AND ACCESSORIES FOR A COMPLETE INSTALLA TlON. .' - FIRE ALARM LEGEND SYMBOL DESCRIPTlON MOUNTlNG AND NOTES 0 FIRE ALARM MANUAL PULL STATlON. 48. AfF TO TOP, U.O.N. ~ fiRE ALARM HORN/fLASHING STROBE LIGHT. 80. AfF TO BOTTOM ~ FIRE ALARM WITH fLASHING STROBE LIGHT. 80. AFF TO BOTTOM FACP fiRE ALARM CONTROL PANEL WlTH 2 LINE DIALER. MATCH EXISTlNG HEIGHT c:::J FARA fiRE ALARM REMOTE ANNUNCIATOR PANEL. M.H. 60. MIN. TO TOP c:::J ~ FIRE ALARM PHOTOELECTRIC S~lOKE DETECTOR. 0 fiRE ALARM HEAT DETECTOR (RATE OF RISE DETECTlON UNLESS NOTED OTHERWISE). o ~ a:oo "I f2 ~ ;3 z> (W) SmlU~ <{I>~~ ~~(/)O ti~j!:~ ~ ~ ~ (/) e ~ lO II) ( ^I 1 (O"I < ~ ~~ ~~~ <8 ~m~~3w o~ffi~~~ g~~;~~ z"'=o ~::J o(/)Il) ;> ~ (/) ~ ~< ~... o(/) REVISIONS JOB NO.: 06-0790 DATE: 10/30/06 SCALE: NOTED DRAWN: BWN CHECKED: MSH SHEET NO. E-1