HomeMy WebLinkAbout06-6218
".
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
6218
Permit Number:
Permit Type:
Class of Work:
Proposed Use:
Square Feet:
Est. Value:
Improv. Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
6218
FIRE PROTECTION
FIRE ALARM SYSTEM
COMMERCIAL
Address: 5814 8TH ST
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number: 11-26-21-0010-02500-0200
.~
11/06/2006 Name: KIDS CORNER
125.00 Address: 5930 8TH ST
125.00 ZEPHYRHILLS, FL. 33542
11/06/2006 Phone: 813 782-3333
FIRE MONITORING PANEL-STROBES/SMOKE DET/PULL STATIONS
. ~,
/,;:\, ,1\
(~AN C\~ \
\ , ~
'-'r
REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
NO OCCUPANCY BEFORE C.O.
iJ1~~ ~.
CONTRACTOR SIGNATURE PERMIT OFFI
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020
City of Zephyrhills Permit Application
Building Department
t-aX-tlM-/tlU-UU;!l
DatB Received
Owner Phone Number
Owner Phone Number I
Owner Phone Number I
OWner's Name
JOB ADDRESS
Owner's Address
Fee Simple Titleholder Namel k, ~ I<~ ~
Fee Simple Titleholder Address I
I S-f-r '-(
I
~
51
~
sr
2 ~I'" 'r" J.., ({ s
I PARCEL ID#I
B
D
o
k
'$ sS- y "2-
lOTN
WORK PROPOSED
~
D
W-
NEW CONSTR
INSTALL
SFR
BLOCK
ADD/ALT
REPAIR
COMM
// _ ;). ~ ;?- (- DO l 0 - 0"2 s-c.c Cf2- CJ"-'
(OBTAINED FROM PROPERTY TAX NOTICE)
SIGN D MOVE 0
DEMOLISH
SUBDIVISION
PROPOSED USE
TYPE OF CONSTRUCTION
FRAME
o
D
o
OTHER I r-=: ll1..J#\"AI I ~~ ( -:J
STEEL D OTHER I
P -1vV c.1/... I
I
DESCRIPTION OF WORK I- \,.-c. V'-t, ~ , J"", . (/....... __I. ~ tyl--&) iI, ~ . ~ l~ ~ tJ .~"t P '" ( ( :> ~
BUILDING SIZE I I ~ "7 ISQ FOOTAGE I 3 ~6 0 -t- I HEIGHT I Z 0 PI: I
I . I I I . . I I ~ I t I I I I . . . ." , I I . . , I . . I . . . . : . . . I I I I . I . . . . , . . . I . . I . . . I . . I I I I . . . . . . I . . . . . . . , I . . . . . . . . . , , . I I . . . . , I . . . . I . . . . . . , . I . I . . I . I . I . . , I . . I . , I . I I . , . . . I . .
D BUILDING 1$ I VALUATION OF TOTAL CONSTRUCTION
D ELECTRICAL 1$ I AMP SERVICE D PROGRESS ENERGY
. Nee ./
D PLUMBING 1$ I F-l ~V'l - ( , I.
D MECHANICAL 1$ I VALUATION OF MECHANICAL INSTALLATION
D GAS 0 ROOFING 0 SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA DYES DNo
11111'f",II..IIII.I.",IIIIIII,..".,I..IIIIIIIIIIII'"111"1.""'1111111111111"'..."'111"...11111'1111,i","""""""IIIII'I"""'I""1
D
W.R.E.C.
BUILDER
SIGNATURE
JVL~~
COMPANY
REGISTERED
L1censB #
Y/N FEE CURRENT
License #
Y/N FEE CURRENT
License #
Y/N FEE CURRENT
License #
Y/ N FEE CURRENT
Y/N
Address
ELECTRICIAN
SIGNATURE
COMPANY
REGISTERED
Address
PLUMBER
SIGNATURE
COMPANY
REGISTERED
Y/N
Address
MECHANICAL
SIGNATURE
COMPANY
REGISTERED
Y/N
Address
OTHER
SIGNATURE
COMPANY
REGISTERED
Y/N
Address License #
i II i i 11111 i i III 1111111 i II , , 1111111111111111111111111111111 i i III i i i Iii i III i i i 1111111111 , 1111 ii' 11111111111111111111111111111 i 11111111111111111111 i
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for nBW construction,
Minimum ten (10) working days after submittal date. RequirBd onsite, Construction Plans, StDrmwater Plans w/ Silt Fence Installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projBCtS
COMMERCIAL Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W PBrmlt for new construction.
Minimum ten (10) working days after submittal date. Required onslte, Construction Plans, Stormwater Plans w/ Silt FencB Installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projBCtS. All commBrcial requirements must meBt compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
....PROPERTY SURVEY required for ail NEW construction.
II)III! 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 111111111111 1111111111111111111I111111111111111
Directions:
Fill out application complBtely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (Ale upgrades over $5000)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs SBwers Service Upgrades AlC Fences (Plot/Survey/Footage)
Driveways-Not over Counter If on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliancl'! with any
applicable deed restrictions. . .
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed In accordance With state and local regulations. if the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violatioh
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the oWner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the constrUction of neW buiidings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance huinber 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportatioh Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid priorto permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction lien LaW-Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to ineet standards. of all laWs regUlating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended Work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, VVetland Areas and Environmentally SensitiVe
Lands, WaterlWastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads; Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida. .
If the fill material is to be used in Flood Zone "N in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem Wall.
If fill material is to be used in any area, I certify that use of such fill will hot adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less thah one (1)
acre which are elevated by fill, an engineered drainage plan is required. .
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical wor~,
plumbing, signs, wells, pools, air conditioning, gas; or other installations hot specifically included in the applicatiorl. A
permit issued shall be construed to be a license to proceed with the work a~d not as authori~y !o violat~, cancel, alter, or
set aside any provisions of the technical codes, n?r shall.lss~ance of a permit prevent the B~II.dlng OffiCial from the~eaft~r
requiring a correction of errors in plans, construction or vlolat~o~s o! any codes., Every ~ermlt Issued. shall become. Invah~
unless the work authorized by such permit is commenced Within SIX months of permit Issuance, or If work authorized. by
the permit is suspended or abandoned for a period of six (6) months after the time th~ work is commenced: An extension
may be requested, in writing, from the Building Official for a period not t~ exceed n1n~ty ~90) da~s and Will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the Job IS conSidered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCiNG, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT (F.S. 117.03)
CONTRACTOR
Subscribed and swom to (or affirmed) before me this
by .
Who Is/are personally known to me or has/have produced
as Identification.
OWNER OR AGENT
Subscribed and swom to (or affirmed) before me this
by
Who Is/are personally known to me or haslhave produced
as identification.
Notary Public
Notary Public
Commission No.
Commission No.
Name of Notary typed. printed or stamped
Name of Notary typed. printed Dr stamped
Fire Chief Robert Hartwig
ZEPHYRHILLS FIRE DEPARTMENT
6907 Dairy Road, Zephyrhills, FL 33542
Bus (813) 780-0041 Fax (813) 780-0044
Occupancy No.:
Plan No.:
Business Name:
BusinessAddress:
Business Phone No.:
Business Fax No.:
Contact:
PLAN REVIEW FEES
~ Site Plan N/C
Building Plans .04 sf
Revision .06 sf
FIRE SERVICE USER FEES
STANDPIPE SYSTEM
D Per Riser $25
SPRINKLER SYSTEMS
QO-25Heads ~
~26 plus Heads ~
FIRE PUMP
D Per Pump $100
FIRE ALARM SYSTEM
D 0 - 25 Devices $30
D 26 plus Devices $60
SUPPRESSION SYSTEMS
~ Wet $35
Dry $35
C02 $35
Other $35
GREASENENTILATION
D Hood/Ducts $35
INSPECTION FEES
Annual N/C
1 st Re-inspection $25
2nd Re-inspection $50
3rd Re-inspection $125
4th Re-inspection $250
5th Re-Inspection $500
Construction $15
Commercial $25
SPRINKLER SYSTEMS
Hydro Undergrounds $45
Hydrostatic System $45
Wet Acceptance $30
Dry Acceptance $45
Hydrant Flow $25
Hood / Booth $30
Grease Duct $15
FIRE ALARM S~
~ System Acceptance ~
o Recall Acceptance $50
OTHER
Fire Wall/Smoke Wall $15
LP Gas $25
Natural Gas $25
Fuel Tanks $25
Tent $15
~lll@t.
~
Billing Phone No.: ~.-
Billing Fax No.:
Contact: A-1 ~-
PERMIT FEE
FALSE ALARM FEE
1 st Alarm N/C
2nd Alarm N/C
3rd Alarm N/C
4th Alarm $25
5th Alarm $50
6th Alarm $75
7th Alarm $100
8th Alarm $150
9th Alarm $200
10th Alarm $250
Non Compliance $150
"Affidavit of Service/Repair"
SPRINKLER SYSTEMS
D Automatic $15
FIRE PUMP
D Fire Pump $15
td1 FIRE ALARM SYSTEM
Lf'J. Detection @
OTHER
~ LP Gas
Natural Gas
Fire Works
Fuel Tanks
$45
$45
$25
$45
GREASENENTILATION
D HoodlDucts $15
t)O D KltChensuppr~eSSlon $15
/ FALSE ALARM
PLANS TOTAL I fdJ r INSPECTION TOTAd PERMIT TOTAL TOTAL I I
/j..~ ~~~ ~ 11
Comm,"ts. uu, :k ~.;-- ~_- _' ~: _ -_ ;~_ . . <f--=-.s..
Date:
1//rJ;r
g"71tnt/d~ .nee
Inspector:
NOTICE OF COMMENCEMENT
State of r-./ ""'" ,"'..... Co unty 0 f PI}:, C<)
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,
and in accordance with Chapter 713, Florida Statutes, the following information is provided in
this Notice of Commencement:
1. Description of Property: Parcel No. II. 2. (. . ~ ( - Do [0- 0 "l...S' 00' ";a.. dO
(Legal description of the property and street address if available)
2. General Description of Improvement
3. Owner Information: Name C ~fr..(y rv, /)L..:.~
Address S~/'1 ~/C1. Sr City 2- ~4 h,.-t.., [(c.
Interest in Property: O<:......J.v ~.""1
State~L $'$ .s-y~
Name of Fee Simple Titleholder:
(If other than owner)
Address
4. Contractor: Name -.Sl\/IJ' ~)j_ ~ CL~('-I 4
Address33'so UL...I'1-1Y-<2-rv.-J fl-A s~',r 17 City CL~~~
City
State
5. Surety: Name
State {'::L 3 ~/{ (..
Address
City
Slate
Amount of Bond: $
6. Lender: Name
Address
7. Persons within the State of Florida designated by Owner upon whom notices or other
documents may be served as provided by Section 713.13 (l ) (a) (7), Florida Statutes:
City
State
Name
City
State
Address
8. In addition to himself, Owner designates
of to receive a copy of the Lienor's Notice as
provided in Section 713.13 (1) (b), Florida Statutes.
I. Expiration date of Notice of Commencement (the expiration date is I year from the date
of recording unless a different date is specified.)
ignature of Owner: L O-H:/{'iU"}tCi , Vf! ()( 0 LIUJ
worn to and subscribed before me this ~ day of 1"\.) () " ~ ~ _, 20~.
otary Publi .
HotIwy Public - si... d Fbfdt
an . 0
Calnmiaaion , DO 511506
........, ~ ~ AIM.
:930530481 A
1 YEAR OLD
CLASSROOM
~
F
-~
-,,~
[J
LAV
~
~
2 YEAR OLD
CLASSROOM
F'
~
3 YEAR OLD
CLASSROOM
F
~
F
Ir---
I~
I \
F
~
t-----------------I
RECEPTION COUNTER
---.-------
OFFICE
KEYED NOTE,S
0) NEW FIRE ALARM CONTROl PANEL 'MTH (2) UNE DIALER.
PROVIDE DEDICATED 20 AMP CIRCUIT fROM AVAILABLE
BREAKER IN PANEl. COORDINATE PHONE SERVICE 'MTH
OWNER.
CD VERIFY REQUIRED LOCA TlON OF FIRE ALARM REMOTE
ANNUNCIATOR 'MTH THE AUTHORITY HAVING JURISDICTlON.
o HIGH TEMP. FIXED HEAT DETECTOR IN ATTlC SPACE.
F
~
{
r" r L, ~
I ',,-
I .
L
::~ L:V 8 LAV IJ {1 LAV c----~ {1 LAV c-=:
~)
F ~-- ---------- F
l::=__
MRS. CATHY'S
OFFICE
~-
F
\-
\",~--
~:
~
~
KITCHEN
'1D4
~
NOTE:
THERE IS NO COOKING
EQUIPMENT IN THIS
KITCHEN.
SCHOOL AGE
ROOM
/
~
F
CORRIDOR
~
~
~
4 YEAR OLD
CLASSROOM
COMMONS AREA
ID4
~
~---
Building shall comply with
the applicable codes of
Florida Fire Prevention Handbook
NFPA & the City of Zephyrhills
FLOOR PLAN - FIRE ALARM SYSTEM
SCALE: 1/4" :::: 1'-0"
APPROVED
by Fire Marshal of Zephyrhills
with comme7~.ts v7~i~ ~~
##'~ /1 /f(t~
'~1l. . U"'~'llI"~
INSPECTION(S) REQUIRED
BY ZEPHYRHILLS ED.
~ ~/lt /k~;ldfU-J6f
, _J // k~')'2'/dCV/''''U-J ,,;7/
.'i- ~/II~#J. S/~.Ut 7 , &PKL.
l' ~ t./,/y,cd.f ~'l~v I? c) /1
;/~. f{" f/It/lc--~cl,
;r(tV/P! ~
~
jf U/ll,f?.d1,"C6f
if} fY<;~
Ii> Cf'C./<,-&(1<
2'\')-~O
GENERAL NOTES
1. BUILDING IS NOT PROTECTED BY A FULLY SUPERVISED FIRE
SPRINKLER SYSTEM.
2. ALARM SEQUENCE: UPON ACTlVATlON OF ANY FIRE ALARM
INITlATlON DEVICE THE FIRE ALARM CONTROL PANEL SHALL
IMMEDIATELY GO INTO GENERAL ALARM CAUSING THE
FOLLOWING TO HAPPEN:
A. ALL AUDIBLE AND VISUAL NOTlFlCA TlON APPLIANCES
SHALL ACTlVATE.
B. DACT SHALL NOTlFY OFF PREMISE MONITORING
STATION OF THE GENERAL ALARM.
3. ALL COMPONENTS AND WORKMANSHIP SHALL MEET OR EXCEED
THE FOLLOWING:
A. NfPA 70 - NATlONAL ELECTRICAL CODE.
B. NfPA 72- NATlONAL FIRE ALARM CODE.
C. ANSI A1171.1-AMERICAN NATlONAL STANDARD
fOR BUILDING AND FACIUTlES PROVIDING
ACCESSIBILITY AND USABILITY FOR PHYSICALLY
HANDICAPPED PEOPLE.
D. NFPA 101-UfE SAFETY CODE.
E. NEC ARTlCLE 760-FIRE PROTECTIVE SIGNALING
SYSTEMS.
F. AMERICANS 'MTH DISABIUTlES ACT OF 1990.
G. FLORIDA ACCESSIBIUTY CODE FOR BUILDING
CONSTRUCTION.
H. flORIDA FIRE PREVENTlON CODE.
I. SYSTEM: UL LISTED.
J. CONFORM TO REQUIREMENTS OF NFPA 101.
K. UL USTED-UL 1076.
4. ALL FIRE ALARM HORNS SHALL HAVE A MINIMUM DB OF 87 AT
10 fEET AND SHALL NOT EXCEED 120 DB.
5. ALL FIRE ALARM STROBES SHALL HAVE A flASH RATE OF AT
LEAST 1 HZ BUT NOT EXCEED 2 HZ.
6. FACP SHALL HAVE BATTERY BACK-UP FOR 24 HOURS 'MTH 5
MINUTES OF ALARM CAPABIUTIES (PER NFPA 72).
7. FIRE ALARM INITlATlON CIRCUIT CABLES SHALL BE 18GA 2
CONDUCTOR RISER RATED FIRE WIRE "HONEYWELL" FlP-R.
CABLE SHALL BE USTED 'MTH UL, FPLR/CL2,C(UL) AND FT4.
8. FIRE ALARM NOTlFlCA TlON APPUANCE CIRCUIT CABLES SHALL
BE 16GA 2 CONDUCTOR RISER RATED FIRE WIRE "HONEYWELL"
FLP-R. CABLE SHALL BE USTED 'MTH UL, FPLR/CL2,C(UL) AND
FT4.
..
...
I . Ie.)
8.5
U 0
~ x
Z 13 '.6
~lV
~ 1:1 ~
en 01O .., Ol
<C> C
~I ""~ ..... 'C
1O['- ';I t1)
M 8 Q)
~~ .., C
.:J .-
~~
E-4~ ~~
~ffi ~c.o
'0 0
~~ NO
~C\/
~~ Q~ "(0
~g ..,
r-
~..
.._ \1')
~~ ~ '~
sas t': C\~
-....
~E ~. ~~
~en ~(;) 'rl
~~ O~ ~ H
-j.j ,
1O. ~Z (lj~rl
Zu ~&; '0 0 ;Sc.;g
~ -.;i" tw.. ~ -..,
~ I~ ~n
.., ~ 0.9.~ .
f;; t~ ~ ~..o
Z -l:a 'rl <l);i':
r- 0 HZ,
~ f!~ Q) ,~
Q) ~ C'
~ ~
'rl ~.~
-<ll b.O~ .""
r:. ~ C'l S
0 ~U5~
~
~
U
S H
, /
F F
/ ,
TYPICAL SIGNAL CIRCUIT
FOR 8LOG'S.
3/4" C. TO TELEPHONE SERVICE
COMM. WITH FARA
F
FACP
FIRE ALARM RISER DIAOnAM
NOT TO SCALE
~
CD PROVIDE CABLING AND ALL OTHER REQUIRED COMPONENTS AND ACCESSORIES FOR A COMPLETE
INSTALLATlON.
o PROVIDE CABLING AND ALL OTtiER REQUIRED COMPONENTS AND ACCESSORIES FOR A COMPLETE
INSTALLA TlON.
.' -
FIRE ALARM LEGEND
SYMBOL DESCRIPTlON MOUNTlNG AND NOTES
0 FIRE ALARM MANUAL PULL STATlON. 48. AfF TO TOP, U.O.N.
~ fiRE ALARM HORN/fLASHING STROBE LIGHT. 80. AfF TO BOTTOM
~ FIRE ALARM WITH fLASHING STROBE LIGHT. 80. AFF TO BOTTOM
FACP fiRE ALARM CONTROL PANEL WlTH 2 LINE DIALER. MATCH EXISTlNG HEIGHT
c:::J
FARA fiRE ALARM REMOTE ANNUNCIATOR PANEL. M.H. 60. MIN. TO TOP
c:::J
~ FIRE ALARM PHOTOELECTRIC S~lOKE DETECTOR.
0 fiRE ALARM HEAT DETECTOR (RATE OF RISE DETECTlON UNLESS NOTED
OTHERWISE).
o
~
a:oo "I
f2 ~ ;3
z> (W)
SmlU~
<{I>~~
~~(/)O
ti~j!:~
~ ~ ~
(/)
e
~
lO
II)
( ^I 1
(O"I
< ~ ~~
~~~ <8
~m~~3w
o~ffi~~~
g~~;~~
z"'=o ~::J
o(/)Il) ;> ~
(/) ~ ~<
~...
o(/)
REVISIONS
JOB NO.: 06-0790
DATE: 10/30/06
SCALE: NOTED
DRAWN: BWN
CHECKED: MSH
SHEET NO.
E-1