Loading...
HomeMy WebLinkAbout07-6126 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 6126 Permit #:61 6 Issued: Permit Type!: GENERAL BUILDING PERMIT Class ofWqrk: 101-NEW CONST/SFR Proposed Use: SINGLE FAMILY RESIDENTIAL Sq. Feet: Est. Value: Cost: 19,152.00 Total Fees: 3,538.55 Amount Pai : Date Paid: Address: 6750 BASSW CIR LOT 37 ZEPHYRHILLS. FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: DRIFTWOOD Parcel Number: 02-26-21-0010-02800-0370 IL MECHANICAL FEJ WATER CONNEC ION RESIDENl FIRE IMPACT FE 1 . 56.70 RADON 419.00 FIRE PLAN REVIEW FEES 273.00 POLICE IMPACT FEE 1 . 13.54 SEWER CONNECTION RESIDENl 54.16 FIRE INSPECTION FEES 254.00 PUBLIC SAFETY 5% 1,616.00 12.50 26.35 S/2D/O'7-(ll~'7 - . ~ n~ ACil u ~ ~ / p<'^.ACX:C~, L 'Ilc f"'~S p..' Q ~ ~ leu\~~.- L~- ~ ,g 5u.-bn~ (1Q....u..:::. p IO/Y\.D t/:.J re..u\ e.e:::, '01.~He5. . DUCTS INSTALLE PRE-SLAB CONSTRUCTION POLE 2ND ROUGH PLUMB DUCTS INSULATE LINTEL PRE-METER WATER SHEATHING FRAME MISC SEWER MISC INSULATION WALL MISC MISC. MISC. INSULATION CEILING MISC. MISC. MISC. DRIVEWAY MISC. MISC. REINSPECTI N FEES: Reinspection fees will comply with Florida statute 553.80 (2)( c) when extra inspection trips are n~sary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty struction c) repairs or corrections not made when inspections called d) work not ready for inspection wh n called e) permit not posted on job site f) plans not at jOb site g) work not accessible. NOTICE: In addtion to the requirements of this permit, there may be additional restrictions applicable to this property that may be found i the public records of this county, and there may be additional permits required from other governmental entities such as. ater management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to 0 ner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recordi g your notice of commencement." &~ TORS SIGNATURE PERMIT OFFI CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 Date Received OWner's Name Owner's Address Fee SImple Tltlehc:llder Name I SUBDIVISION WORK PROPOSEq PROPOSED USE i TYPE OF CONSTRpCTlON DESCRIPTION OF rrORK BUILDING SIZE I ~ ~ ~ ~ City of Zephyrhills Permit Application Building Department Fax-813-780-0021 Owner Phone Number Owner Phone Number I Owner Phone Number I Ej o ~ I~ 1 B D D ()u~ PARCELIDt 1 02 Fee SImple Tltleh~lder Address I JOB ADDRESS. I (d150 R)O. ^,{'\ LUcccQ. lD,,; +.J.wODd Pkc..se JC NEW CONSTR INSTALL SFR BLOCK ADD/ALT REPAIR COMM FRAME u.",: .i \OI.V^ t-\v"1eJ SQFOOTAGE I K 12 ~ 1$ 1$ 1$ 1$ D GAS JtJ FINISHED FLOOR ~LEVATIONS I BUILDIN , ELECTRlpAL PLUMBI~ MECHAN!CAL BUILDER SIGNATURE Address ELECTRICIAN SIGNATURE Address PLUMBER SIGNATURE Address MECHANICAL SIGNATURE Address OTHER SIGNATURE Address RESIDENTIAL COMMERCIAL SIGN PERMIT I I I I D 1 AMP SERVICE VALUATION OF TOTAL CONSTRUCTION PROGRESS ENERGY o o o LOT' 1317 ~ 2.~ .. ~ I ~ 00 I 0- 0:2. g 00 - {Jot 0 (OBTAlNm FROII PROPERTY TAX NOnCE) SIGN 0 MOVE 0 DEMOLISH OTHER STEEL OTHER I ~ o W.R.E.C. ~G_ ~a.~ _ e.~ec\. '3u.b ~~\ CQ.\CS VALUATION OF MECHANICAL INSTALLATION ~ ROOFING SPECIALTY 0 OTHER FLOOD ZONE AREA DYES ~NO i..!i.~4t'\ Lol'lsf.,. TI1 C r Y / N I FEE CURR~NT I Y I N License , I So ~ "l-e", 1"\ LD"J'\ tor f I Y/ N I FEE CURRENT I Y/N license' I COMPANY l.J.fI/'l'\ c::I.l'\ f!.eo1.'",~ REGISTERED r Y I N I FEE CURRENt Y I N License , I ~ltach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Fonns r-'!inlmum ten (10) working days after submittal date. Required onsile, Construction Plans, Sanitary Fadlllies & 1 dumpster fA.ltach (3) sets of Building Plans; (1) set of Energy Fonns. inimum ten (10) working days after submittal date. Required onslle, Construction Plans, Sanitary Fadlllies & 1 dumpster " commerda' requirements must meet compliance. ttach (2) sets of Engineered Plans. "PROPERTY SURVEY reqUired for all NEW construction. DIrectIons: Fill out appllcalio completely. Owner & Conlra or sign back of application, notarized If over $2500, a otic. of Commencement Is requIred. (AlC upgrades over $5000) Agent (for the co trador) or Power of Atlomey (for the owner) would be someone with notarized letter from owner authorizing same, OVER THE COUNTE PERMITTING (Front of Application Only) Reroofs ewers Service Upgrades AlC Fences (PloIISurveylFoolage) Driveways-Not 0 er Counter if on public roadways..needs ROW Ryman Canst-Basswood Cr-6750 Lot 37 SQ. FEET PRICE MAIN OR LIVING: 1,354 $ 88.00 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 119,152.00 FEE SHEET $ 540.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 610.80 ELECTRICAL: $ 121.50 PLUMBING: $ 81.00 MECHANICAL: $ 56.70 SUB-TOTAL $ 870.00 RADON: $ 13.54 TOTAL $ 883.54 SEWER: $ 1,616.00 WATER: $ 419.00 IRRIGATION: $ - TOTAL: $ 2,035.00 WATER METER:I $ IRRIGATION METER $ I Master Meter-n/a FIRE DEPARTMENT FEES PLANS TOTAL: $ 54.16 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL: $ 66.66 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,538.55 I PARK IMPACT FEES I $ 769.56 I SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - Exempt Exempt TIF'S: $ 1,588.00 99% $ 1,572.12 1% $ 15.88 TOTAL: $ 5,896.11 I I , FORM 600A-2004 3 EnergyGauge@ 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A .~.. DRIFTWOOD TOWN HOMES . BR TRIPLEX MID Builder: RYMAN CONST. -Mle8'& (0'150 i'O~cc&.. 6 (" tJ-37 Permitting Office: PASCO CO. Z-HILLS, FL Permit Number: (0120 RYMAN CONST. Jurisdiction Number: 611~OO Central Project Name: Address: City, State: Owner: Climate Zone: I. New constnlcti n or existing New 2. Single family multi-family Single family 3. Numberofuni, ifmulti-family I 4. NumberofB ms 2 5. Is this a worst e? Yes 6. Conditioned fl r area (ft') 1364 ft, 7. Glass typel an area: (Label reqd by 13-104.4.5 ifnot default) a. U - factor: Description Area (or Single or Dl>uble DEFAULT) 7a(Sngle Default) 62.0 ft, b. SHGC: (or Clear or T~t DEFAULT) 8. Floor types a. Slab-On-Grade kdge Insulation b. N/ A r c. N/A 9. Wall types a. Frame, Wood, t.acent b. Concrete, Int Ins , Exterior c. Concrete, Int Ins , Adjacent d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: 4nc. AH(Sealed):Garage Sup. R=6.0, 100.0 ft b. N/A Th. (Clear) 62.0 ft, R=O.O, 158.0(p) ft . R=11.0, 160.0 ft, R=7.5, 240.0 ft, R=11.0, 864.0 ft2 R=30.0, 1364.0 ft, 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heatingsystems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR.-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CY-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Cap: 36.0 kBtu/hr SEER: 13.00 Cap: 33.0 kBtu/hr COP: 1.00 Cap: 40.0 gallons EF: 0.94 Gla~s/Floor Area: 0.05 I I Total as-built points: 16258 Total base points: 18452 PASS Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed I this building will be inspected for compliance with Section 553.99Q. I Florida Statutes. f-/- ! BUILDING O!'0'rL: J J J I DATE: Cl 0 'ic I . For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGaug~ (Version: FLRCSB v4.0) I hereby certify that he plans and specifications covered by this calculation are i compliance with the Florida Energy Code. I "', PREPARED BY~ t\A\i:, \.-:J-..f<. vtAr-,"--'.... DATE: i Co du...-\ 0 I hereby certify that t is building, as designed, is in compliance with the Florida Ene y C~ \ OWNERlAGEN : ~<:...-Q~ ,. ~ --,"'--_ DATE: L- :r u--\. 1 Predominant glass ty I , FORM 600A-2004 EnergyGauge@ 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details , ADDRESS:! PASCO CO., Z-HILLS, FL, PERMIT #: BASE AS-BUlL T GLASS TYPE! .18 X Conditi. ned X BSPM = Points Overhang Floor A ea Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1360 .0 25.78 6329.5 Single, Clear E 1.5 2.0 62.0 63.97 0.61 2403.3 As-Bullt Total: 62.0 2403.3 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 1024.0 0.70 716.8 Frame, Wood, Adjacent 11.0 160.0 0.70 112.0 Exterior 240.0 1.90 456.0 Concrete, Int Insul, Exterior 7.5 240.0 0.75 180.0 Concrete, Int Insul. Adjacent 11.0 864.0 0.30 259.2 Base Total: 1264.0 1172.8 Aa-Built Total: 1264.0 551.2 DOOR TYPES I Area X BSPM = Points Type Area X SPM = Points Adjacent ! 21.0 1.60 33.6 Exterior Wood 48.0 7.20 345.6 Exterior 69.0 4.80 331.2 Adjacent Wood 21.0 2.40 50.4 Exterior Wood 21.0 7.20 151.2 Base Total: 90.0 364.8 Aa-Bullt Total: 90.0 547.2 CEILING TYPE~ Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1364.0 2.13 2905.3 Under Attic 30.0 1364.0 2.13X 1.00 2905.3 Base Total: ! 1364.0 2905.3 As-Bullt Total: 1364.0 2905.3 ! FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 1 8.0(p) -31.8 -5024.4 Slab-On-Grade Edge Insulation 0.0 158.0(p -31.90 -5040.2 Raised 0.0 0.00 0.0 Base Total: -6024.4 As-Built Total: 158.0 -5040.2 INFILTRATION Area X BSPM = Points Area X SPM = Points ! 1364.0 14.31 19518.8 1364.0 14.31 19518.8 Summer BasE Points: 25266.9 Summer As-Built Points: 20885.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier MUltiplier Points (System - Points) (OM x OSM x AHU) (sys 1: Central Unit 36000 btuh ,SEERlEFF{13.0) DucIs:Unc(S),Unc(R),Gar(AH),R6.0{INS) 20886 1.00 (1.09 x 1.150 x 0.95) 0.262 1.000 6506.0 25266.9 0.4266 10778.8 20885.7 1.00 1.188 0.262 1.000 6506.0 EnergyGauge l10t DCA Form 600A-20Q4 I . FORM 600A-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Re~idential Whole Building Performance Method A - Details ADDRESS: I PASCO co., Z-HILLS, FL, PERMIT #: BASE AS-BUlL T GLASS TYPE! .18 X Conditi( ned X BWPM = Points Overhang Floor A ea Type/SC Omt Len Hgt Area X WPM X WOF = Poinu .18 13&l.0 5.86 1438.7 Single, Clear E 1.5 2.0 62.0 12.37 1.11 854.7 As-Built Total: 62.0 854.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 1024.0 1.80 1843.2 Frame, Wood, Adjacent 11.0 160.0 1.80 288.0 Exterior 240.0 2.00 480.0 Concrete, Int Insul, Exterior 7.5 240.0 2.20 528.0 Concrete, Int Insul, Adjacent 11.0 864.0 1.10 950.4 Base Total: 1264.0 2323.2 As-Built Total: 1264.0 1766.4 DOOR TYPES I Area X BWPM = Points Type Area X WPM = Points Adjacent r 21.0 4.00 84.0 Exterior Wood 48.0 7.60 364.8 Exterior 69.0 5.10 351.9 Adjacent Wood 21.0 5.90 123.9 Exterior Wood 21.0 7.60 159.6 Base Total: 90.0 435.9 As-Built Total: 90.0 648.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1364.0 0.64 873.0 Under Attic 30.0 1364.0 0.64 X 1.00 873.0 Base Total: i 1364.0 873.0 As-Built Total: 1364.0 873.0 FLOOR TYPES I Area X BWPM = Points Type R-Value Area X WPM = Points Slab 1~8.0(p) -1.9 -300.2 Slab-On-Grade Edge Insulation 0.0 158.0(p 2.50 395.0 Raised 0.0 0.00 0.0 Base Total: -300.2 As-Built Total: 158.0 395.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1364.0 -0.28 -381.9 1364.0 -0.28 -381.9 Winter Base f ~ints: 4388.7 Winter As-Built Points: 4155.4 Total Winter X ystem = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (OM x DSM x AHU) (sys 1: Electric Strip 33000 btuh ,EFF(1.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0 4155.4 1.000 (1.078 x 1.160 x 0.95) 1.000 1.000 4936.5 4388.7 0.&274 2753.5 4155.4 1.00 1.188 1.000 1.000 493&.5 EnergyGauge TM DCA I=orm 600A-2004 I . FORM 600A-2004 WAfER HEATING & CODE COMPLIANCE STATUS Re$idential Whole Building Performance Method A - Details EnergyGauge@ 4.0 ADDRESS: iPASCO co., Z-HILLS, FL, PERMIT #: BASE AS-BUlL T WATER HEATI NG Number of ;k Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms I Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.94 2 1.00 2407.66 1.00 4815.3 i As-Bullt Total: 4815.3 I CODE COMPLIANCE STATUS I I BASE AS-BUlL T Cooling + I Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points i Points Points Points Points Points Points Points 10779 2753 4920 18452 6506 4936 4815 16258 I PASS I EnergyGauge no DCA Form 600A-2004 I . FORM 600A-2004 EnergyGauge@ 4.0 Code Compliance Checklist Residential Whole Building Performance Method A - Details ! , ADDRESS:: PASCO CO., Z-HILLS, FL, 6A-21 INFIL TAA TION REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows 1& Doors 606. 1.ABC. 1. 1 Maximum:.3 cfm/sq.ft. window area; .5 cfmIsq.ft. door area. Exterior & Adjace ltWalls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; jOints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606. 1.ABC. 1 .2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is Recessed lighting Fixtures installed that is sealed at the perimeter, at penetrations and seams. 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi-story Houses ! 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additionallnfiltratio~ reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER I ~RESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir Swimming Pools & $pas breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pOOls must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Syst~ms 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached. sealed. insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 CeilingS-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGauge 1M DCA ~orm 600A-2004 EnergyGauge4lllFlaRES'2004 FLRCSB v4.0 ENERGY PERFORMANCE LEVEL (EPL) DISPLA Y CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 86.2 The higher the score, the more efficient the home. RYMAN CONST., PASCO CO., Z-HlllS, Fl, I. New construct on or existing New 2. Single family r multi-family Single family 3. Nwnberofuni, if multi-family I 4. NwnberofB 2 5. Is this a worst ase? Yes 6. Conditioned fl r area (ft2) 1364 ft2 7. Glass type I an area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: j Description Area (or Single or Ljouble DEFAULT) 78(Sngle Default) 62.0 ft2 b. SHGC: ' (or Clear or T~t DEFAULT) 8. Floor types ! a. Slab-On-Grade!Edge Insulation b. N/A . c. N/A 9. Wall types a. Frame, Wood,~djacent b. Concrete, lot ul, Exterior c. Concrete, lot lo ul, Adjacent d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A II. Ducts . a. Sup: Unc. Ret: ~nc. AH(SeaJed):Garage Sup. R=6.0, 100.0 ft b. N/A Th. (Clear) 62.0 ft2 R=O.O, I 58.0(p) ft R=II.O, 160.0 ft2 R=7.5, 240.0 ft2 R=11.0, 864.0 ft2 R=30.0, 1364.0 ft2 12. Cooling systems a. Central Unit Cap: 36.0 kBtu/hr SEER: 13.00 b. N/A c. N/A 13. Heating systems a. Electric Strip Cap: 33.0 kBtu/hr COP: 1.00 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.94 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pwnp) 15. HVAC credits (CF-Ceiling fan. CY-Cross ventilation, HF-Whole house fan. PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that thiS~ h e has complied with the Florida Energy Efficiency Code For Building Construction throu the above energy saving features which will be installed (or exceeded) in this home befo final inspection. Otherwise, a new EPL Display Card will be completed based on installed ode compliant features. Builder Signature: I Date: i Address of New H9me: City/FL Zip: *NOTE: The home' estimated energy performance score is only available through the FLA/RES computer program. This is not a BuiLdi g Energy Rating. If your score is 80 or greater (or 86 for a us EPAlDOE EnergyStar1Mdesignation), your home may qu ifY for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy auge Hotline at 321/638-1492 or see the Energy Gauge web site at wwwfiec.ucfedufor information and a I t of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, conta t the Department of Community Affairs at 850/487-]824. I Predominant glass For actual glass type and are~ see Summer & Winter Glass outtlut on.J!..ages 2&4. cnergyGauge@(Version: FLRC:SH v4.0) Residential System Sizing Calculation Summary Project Title: DRIFTWOOD TOWN HOMES ~ BR TRIPLEX MID '1 RYMAN CO~ST. ZEPHYRHILLS, FL Code Only Professional Version Climate: Central Location for eather data: Tampa - Defaults: Latitude(28) Temp Range(M) Humidi da : Interior RH 50% Outdoor wet bulb 77F Humid. difference 54 r. Winter desig temperature 40 F Summer design temperature Winter setpoi t 70 F Summer setpoint Winter tem ture difference 30 F Summer tern erature difference Total heatln load calculation 22196 Btuh Total coolin load calculation Submitted he ting capacity % of calc Btuh Submitted cooling capacity Total (Electri Heat Pump) 162.2 36000 Sensible (SHR = 0.75) Heat Pump + uxiliary(O.OkW) 162.2 36000 Latent Total Electric Heat Pum Winter Heatin Load Load com on nt Window total Wall total Door total Ceiling total Floor total Infiltration Subtotal Duct loss TOTAL HEAT 62 sqft 1264 sqft 84 sqft 1364 sqft 158 ft 291 cfm 91 F 75 F 16 F 26478 Btuh % of calc Btuh 185.9 27000 75.3 9000 136.0 36000 WINTER CALCULATIONS Load 2151 3115 1063 1364 3839 9607 21139 1057 22196 Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh 0.-8(5%) SUMMER CALCULATIONS for 1364 s ft Summer Cooli Load Load com one t Window total Wall total Door total Ceiling total Floor total Infiltration Internal gain Subtotal(sensi Ie) Duct gain Total sensible ain Latent gain(infilt tion) Latent gain(inter al) Total latent gai TOTAL HEAT G IN 62 sqft 1264 sqft 84 sqft 1364 sqft 280 cfm Load 1736 Btuh 958 Btuh 761 Btuh 1828 Btuh o Btuh 4923 Btuh 3000 Btuh 13206 Btuh 1321 Btuh 14526 Btuh 10272 Btuh 1680 Btuh EnergyGaugd s~ Sjzjn~ b~n ACCA Manual J. 11952 Btuh PREPARED BY: t ,,-. ~__ L LvL-=-. DATE' 6 "'TG-l 0 J 26478 Btuh . U( In EnergyGauge@ FLRCPB v3.4 L_InftI~) RYMAN CONIsT. System Sizing Calculations - Winter Residential Load - Component Details Project Title: DRIFTWOOD TOWN HOMES 2 BR TRIPLEX MID Code Only Professional Version Climate: Central ZEPHYRHILLIS, FL Reference Cit : Tampa (Defaults) Winter Temperature Difference: 30.0 F 7/6/2006 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 1, Clear, Metal, DEF N 10.0 34.7 347 Btuh 2 1, Clear, Metal, DEF S 10.0 34.7 347 Btuh 3 1, Clear, Metal, DEF S 42.0 34.7 1457 Btuh Window Total 62 2151 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete - Adjacent 7.5 864 2.3 1987 Btuh 2 Concrete - Exterior 7.5 240 3.5 840 Btuh 3 Frame - Adjacent 11.0 160 1.8 288 Btuh Wall Total 1264 3115 Btuh Doors Type Area X HTM= Load 1 Wood - Exter 21 13.8 290 Btuh 2 Wood - Adjac 21 9.2 193 Btuh 3 Wood - Exter 42 13.8 580 Btuh Door Total 84 1063Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 1364 1.0 1364 Btuh Ceilina Total 1364 1364Btuh Floors Type R-Value Size X HTM= Load 1 Slab-On-Grade Edge Insul 0 158.0 ft(p) 24.3 3839 Btuh Floor Total 158 3839 Btuh Infiltration Type ACHX Building Volume CFM= Load Natural 0.40 13640(sqft) 91 3007 Btuh Mechanical 200 6600 Btuh Infiltration Total 291 9607 Btuh I ! TO~IS for Heating Subtotal 21139 Btuh Duct Loss(using duct multiplier of 0.05) 1057 Btuh Total Btuh Loss Key: Window types ( )HGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (>=rame types - metal, wood or insulated metal) (LJ - Window U-Factor or 'DEF' for default) ( 'ITM - ManualJ Heat Transfer Multiplier) Key: Floor size (perin eter(p) for slab-on-grade or area for all other floor types) 22196 Btuh EnergyGauge@ FLRCPB v3.4 System Sizing Calculations - Summer Residential Load - Component Details Project Title: DRIFTWOOD TOWN HOMES 2 BR TRIPLEX MID RYMAN CON~T. ZEPHYRHILLS, FL Reference Cit : Tampa (Defaults) Summer Temperature Difference: 16.0 F Window 1 2 3 Walls 1 2 3 Doors 1 2 3 Type PElneslSHGC/UllnSh/ExSh Omt 1 Clear, DEF, N, N N 1, Clear, DEF, N, N S 1, Clear, DEF, N, N S I \jl. indow Total T pe C ncrete - Adjacent Cl ncrete - Exterior Fr me - Adjacent I '^ all Total T)pe W ad - Exter We od - Adjac We 100 - Exter Deor Total Ceilings Ty e/Color 1 Unc er Attic/Dark Floors 1 Overhang Len Hat 1.5 2 1.5 2 1.5 2 Window Area(sqft) Gross Shaded Unshaded 10.0 0.0 10.0 10.0 10.0 0.0 42.0 42.0 0.0 Shaded 28 28 28 62 R-Value 7.5 7.5 11.0 Area 864.0 240.0 160.0 1264.0 Area 21.0 21.0 42.0 R-Value 30.0 84.0 Area 1364.0 Ce linQ Total TYI e Sla -On-Grade Edge Insulation Flo)r Total Infiltration Ty~ e Natl al Mec anical lntil ration Total Internal aain Total. 101 Cooling I R-Value 0.0 1364.0 Size 158.0 ft(p) ACH 0.35 158.0 Volume 13640 Occupants 6 Btuh/occupant X 300 + HTM Unshaded 28 45 45 HTM 0.5 1.4 1.0 HTM 9.1 9.1 9.1 HTM 1.3 HTM 0.0 CFM= 79.7 200 280 Appliance 1200 Subtotal Duct gain(using duct multiplier of 0.10) Total sensible gain Latent infiltration gain (for 54 gr. humidity difference) Latent occupant gain (6 people@230 Btuh per person) Latent other gain TOTAL GAIN Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U Window U-Factor or 'DEF' for default) (In ~h - Interior shading device: none(N), BlindslDaperies(B) or Roller Shades(R)) (8 Sh - Exterior sh~ding. device: non~6.w~8Qi11~~PB 34 10;,t - comDass onentatlon) v . Code Only Professional Version Climate: Central 7/6/2006 Load 280 Btuh 280 Btuh 1176 Btuh 1736 Btuh Load 459 Btuh 342 Btuh 157 Btuh 958 Btuh Load 190 Btuh 190 Btuh 381 Btuh 761 Btuh Load 1828 Btuh 1828 Btuh Load o Btuh o Btuh Load 1403 Btuh 3520 Btuh 4923 Btuh Load 3000 Btuh 13206 Btuh 1321 Btuh 14526 Btuh 10272 Btuh 1380 Btuh 300 Btuh 26478 Btuh BUILDING INPUT SUMMARY REPORT TItle: DRIFTWOOD TOWN HOMES 2 Bllmily Type: Single Address Type: Street Address ... Owner: RYMAN CONST. New/Existing: New Lot.: NJA 0 . of Unit!!: 1 Bedrooms: 3 Subdivision: NJA W ., Builder Nlame: RYMAN CONST. Conditioned Area: 1364 Platbook: N/A 0 Climate: Central Total Stories: 1 Street: (blank) 0::: a. Penn it 01 lice: PASCO CO. Worst Case: Yes County: PASCO Jurisdlcti I>n': (blank) Rotate Angle: (blank) City, St, Zip: ZEPHYRHILLS, FL, rn 1# Floor l' pe \u.a"~1 R-Val ArealPerimeter Units # Door Type Orientation Area Units rn 0:::1 Slab-On-G rade Edge Insulation 0.0 158.0(p) It 1 0::: 1 Wood Exterior 21.0 It" 1 0 0 2 Wood Adjacent 21.0 It" 1 0 0 3 Wood Exterior 42.0 It" 1 ~ C U- rn # Ceiling ~pe R-Val Area Base Area Units C) # System Type Efflclency Capacity C) 1 Under Attic 30.0 1364.0 It" 1364.0 It" 1 Z 1 Central Unit SEER: 13.00 36.0 kBtulhr Z ::i ::i 0 W 0 0 Credit MulUpD IrS: None 0 Credit Mulllpllers: None i# Wall Type Location R-Val Area Units # System Type Efflclency Capacity 1 Concrete B ~ - Int Insul Adjacent 7.5 864.0 It" 1 C) 1 Electric Heat Pump COP: 8.40 36.0 kBtulhr rn Z ~ 2 Concre1e B Pel< - Int 'nsul Exterior 7.5 240.0 It" 1 i= ~ 3 Frame - Wlloo Adjacent 11.0 180.0 It" 1 ~. c( w I J: Credit Multipliers: None Unlb # S:n Return AIr Handler Su8f.Y supc:x 1# Panes Tint Omt Area OH Length OH Hght L Location Location R- I Len Single Clear N rn 1 Unc:ond. Uncond. Garage 6.0 100.0 It 1 10.0 It" 1.5 It 2.0 It 1 ... 2 Single Clear S 10.0 It" 1.5 It 2.0ft 1 0 3 Single Clear S 42.0 It" 1.5 It 2.0 It 1 ::::) C Credit MulUpllers: AHU seaJed 0::: # Syatem Type EF Cap. Conservation Type Con.EF W 1 Electric Resistance 0.92 40.0 None 0.00 ... ~ rn # Use Def8ult? Annual Operating eo.t Electric Rate ~ a:: 1 Yes NJA NJA 0 U- C W Z 0::: i I Rater Name CocIeOnlyPro Class .: 3 Pool Size: 0 0 Rater Certitl i:atlon #: CocIeOnlyPro Duct Leekage Type: NJA Pump Size: 0.00 hp rn Area Under luorescent: 0.0 Visible Duct Disconnects: NJA Dryer Type: Electric i Area Under ~candescent: 1364.0 Leek F.... Duct System Propoeed: No Stove Type: Electric NOTE: Not i ,I RatIng info shown HRVIERV System Present?: No Avg Ceil Hgt:10 , EnergYGaugeCIP (Version: FLRCPB v3.4)