Loading...
HomeMy WebLinkAbout07-6992 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 FIRE STANDPIPES PERMIT 6992 Permit Number: 6992 Permit Type: FIRE HOOD SUPPRESSION SYS Class of Work: FIRE-HOOD SUPPRESSION SYS Proposed Use: COMMERCIAL Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: Address: 37411 EILAND BLVD ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 03-26-21-0010-05300-0000 9/26/2007 80.00 80.00 9/26/2007 HOOD SUPPRESSION SYSTEM Phone: I FIRE PLAN REVIEW FEES h ()aJ.'l(~ rz.-I If ( cq I~ FIRE DEPT. FINAL Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned, Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." N U PERMIT EX IN 30 DAYS WITHOUT APPROVED INSPECTION CALL OR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 813-780-0020 City of Zephyrhills Permit Application Building Department Fax-813-780-0021 Date Received 'I I I Fee Simple Titleholder Address I I :8?1I//df~1~:~~l~~~.a'~p (OBTAINED FROM PROPERTY TAX NOnCE) D NEW CONSTR E3 ADD/AL T D SIGN D MOVE D D INSTALL REPAIR PROPOSED USE D SFR D COMM D OTHER TYPE OF CONSTRUCTION D BLOCK D FRAME D STEEL D I/N-57A/.? ~/Vsq~ ,.g ys~ I SO FOOTAGE I I HEIGHT I I I I I I D I "'~~'~:::::",~L. Owner Phone Number I ,o!~lmll Owner's Name N.-8t.. ...11 l'itlll1 1.:1 JOB ADDRESS SUBDIVISION WORK PROPOSED DEMOLISH OTHER I I I ~.~ SlPl'iPSS~Vr. DESCRIPTION OF WORK BUILDING SIZE D 1$ D ELECTRICAL 1$ D PLUMBING 1$ D MECHANICAL 1$ D GAS D FINISHED FLOOR ELEVATIONS I BUILDING VALUATION OF TOTAL CONSTRUCTION AMP SERVICE D PROGRESS ENERGY D WR.E.C. VALUATION OF MECHANICAL INSTALLATION ROOFING SPECIALTY D OTHER FLOOD ZONE AREA DYES DNO COMPANY REGISTERED ~ COMPANY REGISTERED ~ COMPANY REGISTERED ~ I I I I I I I I I FEE CURRENT ~ License # ~3~5QfjOOal/7d BUILDER SIGNATURE FEE CURRENT ~ Address License # ELECTRICIAN SIGNATURE FEE CURRENT ~ Address License # PLUMBER SIGNATURE FEE CURRENT ~ Address License # Add ress MECHANICAL SIGNATURE ~ FEE CURRENT ~ License # OTHER SIGNATURE COMPANY REGISTERED ~ Address M~~t.mnmmm0m~ RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Sanitary Facilities & 1 dumpster Attach (3) sets of Building Plans; (1) set of Energy Forms. Minimum ten (10) working days after submittal date. Required onsite. Construction Plans, Sanitary Facilities & 1 dumpster All commercial requirements must meet compliance. Attach (2) sets of Engineered Plans. '-'PROPERTY SURVEY required for ail NEW construction. COMMERCIAL SIGN PERMIT Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AlC upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades AlC Fences (PloUSurvey/Footage) Driveways-Not over Counter if on public roadwaysHneeds ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified. in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law---Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterlWastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU WITH YOUR LEN DE AN ATTORNEY BEFORE RECORDING YOU FLORIDA JURAT (F. 17.03 Islare r haslh ve produced as identification. ~~"'""' Commission No. Name of Notary tvped, orinted or stamped . ~.~:"': FRANCIS G. SPERLAZZA I ~ MY COMMISSION # DD347356 <I).~ ';;f'~ EXPIRES: November 26, 2008 1.80~~3.NOTARY Fl. Notary Discount Assoc. Co. Name of Notary typed, printed or stamped ~"""vPu~ FRANCIS G. SPERLAZZA ~~ MY COMMISSION # DD347356 ~ EXPIRES: November 26.2008 I-iC:3-NOTARY FI. Notary Discount Assoc. Co. Fire Chief Robert Hartwig ,-+~ q1 ty ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813) 780-0041 Fax (813) 780-0044 FIRE SERVICE USER FEES Occupancy No.: ~ vAla Plan No.: Of~ f. Billing Address: Business Name: ~)\J~ ~ BusinessAddress: VI k~ A. Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES ~ Site Plan N/C Building Plans .04 sf Revision .06 sf STANDPIPE SYSTEM o Per Riser $25 SPRINKLER SYSTEMS n 0 - 25 Heads $30 o 26 plus Heads $60 FIRE PUMP o Per Pump $100 FIRE ALARM SYSTEM o 0 - 25 Devices $30 o 26 plus Devices $60 rn. SUPPRESSION SYSTEMS et $35 Dry $35 C02 $35 Other $35 GREASENENTILATION o Hood/Ducts $35 It{; PLANS TOTAL rn INSPECTION FEES Annual N/C 1 st Re-inspection $25 2nd Re-inspection $50 3rd Re-inspection $125 4th Re-inspection $250 5th Re-Inspection $500 Construction $15 Commercial $25 SPRINKLER SYSTEMS Hydro Undergrounds $45 Hydrostatic System $45 Wet Acceptance $30 Dry Acceptance $45 Hydrant Flow $25 , Hood / Booth <:S> Grease Duct $15 FIRE ALARM SYSTEM o System Acceptance $50 o Recall Acceptance $50 OTHER Fire Wall/Smoke Wall $15 LP Gas $25 Natural Gas $25 Fuel Tanks $25 Tent $15 INSPECTION TOTA~ GRAND TOTAL Billing Phone No.: Billing Fax No.: Contact: 3'~2- ~-~S<: PERMIT FEE FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $25 5th Alarm $50 6th Alarm $75 7th Alarm $100 8th Alarm $150 9th Alarm $200 10th Alarm $250 Non Compliance $150 "Affidavit of Service/Repair" SPRINKLER SYSTEMS o Automatic $15 FIRE PUMP o Fire Pump $15 FIRE ALARM SYSTEM o Detection $15 OTHER ~ LP Gas Natural Gas Fire Works Fuel Tanks $45 $45 $25 $45 GREASENENTILATION ~OOd/DUcts ~ Itch en suppresSio~~ FALSE ALARM I PERMIT TOTAL TOTAL. DD~ Comments: 8/iff;.7 . FYY 6A//I/?#'/#f- Date: Inspector: HERNANDO FIRE & SAFETY EQUIPMENT CO., INC. 1109 Ponce De Leon Boulevard Brooksville, Florida 34601 Phone: 352-796-4433 Fax: 352-796-5679 1-800-330-6230 Ansul R~ 102 (UL300) liquid chemical fire suppression system. Installed per NFPA-17A, NFPA-96, state/local codes, and manufacturer's specifications. Gas valve, make-up air and any electrical sources under the hood are tied into the system for automatic shut down. Facility fire alarm (if installed) sounds with system activation. Remote manual pull station to be located per Florida Standard Mechanical Code, a minimum of 10ft. and maximum of 20 ft. from the cooking equipment unless an alternate location is specifically approved by the mechanical official. Piping limitations and nozzle placement to be in accordance with Ansul R -102 design and installation manual. Submitted By: Hernando Fire & Safety Eqpt. Co., Inc. 1109 Ponce De Leon Blvd. Brooksville, Fl. 34601 (800-330-6230) Florida State License # 43750500011988 Job Site: West Wind ALF 37411 Eiland Blvd. Zephyrhills, FL 33542 ~'\l ~\t\\ hal\ cort\V 'J ~ ,,\\\\U\\\~ ~\\cab\e ~od.~~d.bO('\' IDe aVV dent\01\ ... ~\\\,.;, . Yte". ~"jt!lJ. . r\otid.a ru:e Cl~ 0\ ~V ~J\. 8L me ,. .........., 1:--) ~,.,-" .:'... - @]AN~L~I Install Date: .undefined West Wind ALF 37411 Eiland Blvd. Zephyrhills, FL 33542 undefined undefined Hernando Fire & Safety Eqpt. Co. 11 09 Ponce De Leon Bid. Brooksville, Florida 34601 Kent Ferguson 352-796-4433 hernandofiresafe@bellsouth.net R.Uc.#437S0S00011988 Untitled System page 1 of 5 ~ANSUL~I Install Date.:.undefined West Wind ALF 37411 Eiland Blvd. Zephyrhills, FL 33542 undefined undefined Hernando Fire & Safety Eqpt. Co. 1109 Ponce De Leon Bid. Brooksville, Florida 34601 Kent Ferguson 352-796-4433 hernandofiresafe@bellsouth.net FI. Lie. #43750500011988 Untitled System Untitled Layout Flow Summary: Coverage Hood: Single Bank Duct: Square Range: 6 burners, obstruction Griddie, obstruction Fryer. 1 vat Total Flow Points ! Overall Dimensions Nozzle 146x54in. 1Nx2 2 20x12in. 2W 2 36 x 33 in. 290 x2 4 24 x 33 in. 1 N 1 15.5 x 29.3 in. 230 2 Flows : Nozzle Location .__._--_..__.._-~-_._--------~-----_.,---_.__._.-_. . 0-4 in. from filter face, center of height dimension, aimed down filter length. 2-8 in. into center of duct opening, aimed up 15 in.-20 in., 2290 nozzles, opposite sides, each 0-1.5 in. from edge and 0-2 35 in.-40 in., 0-2 in. inside perimeter, aimed at center 27 in.-47 in., alonglwithin perimeter, aimed at center ... See Note 1 11 page 2 of 5 ~ANSUL~I Install Date: undefined West Wind ALF 37411 Eiland Blvd. Zephyrhills, FL 33542 undefined undefined Hernando Fire & Safety Eqpt. Co. 11 09 Ponce De Leon Bid. Brooksville, Florida 34601 Kent Ferguson 352-796-4433 hernandofiresafe@bellsouth.net FI. Lie. #43750500011988 Notes Fusible Links: => To determine actual fusible link ratings, temperature readings must be taken during peak cooking time. Untitled Layout: Note 1 => Nozzle: 290 x2: (Range: 6 bUrners, obstruction) nozzle position: 1 5 in.-20 in., 2 290 nozzles, opposite sides, each 0- 1.5 in. from edge and 0-2 in. from longitudinal centerline, aimed with 450 angle at longitudinal centerline Note 2 => Griddle, obstruction: The nozzles must be positioned so that the discharge is not obstructed and will see all areas of the cooking surface. page 3 of 5