HomeMy WebLinkAbout07-7165
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
FIRE ALARM SYSTEM PERMIT
7165
Permit Number: 7165
Permit Type: FIRE ALARM SYSTEM
Class of Work: FIRE ALARM SYSTEM
Proposed Use: COMMERCIAL
Square Feet:
Est. Value:
Improv, Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
Address: 5048 AIRPORT RD
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number: 12-26-21-0000-04900-0010
11/02/2007
150.00
150.00
11/02/2007
FIRE ALARM SYSTEM ADDITION
Name: ZEPHYR DEVELOPMENT LLC
Address: 1414 W. SWANN
TAMPA, FL
Phone: 813 579-2011
50.00
~~~
M. (3J~
1\-14-07
Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities such as inspections, plan review, administrative fees, and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All
work shall be performed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECO DING YOUR NQ E OF COMMENCEMENT."
CONTRACTOR SIGNA TEl
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED
ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041
813-780-0020
City of Zephyrhills Permit Application
Building Department
Date Received
Owner's Name
Owner Phone Number
Owner Phone Number I
Owner Phone Number I
Owner's Address
Fee Simple Titleholder Name
Fee Simple Titleholder Address
AI A-/J~A-r /td
I PARCELlD#1
D NEW CONSTR c=J ADD/AL T D
D INSTALL CJ REPAIR
PROPOSED USE D SFR D COMM D
TYPE OF CONSTRUCTION D BLOCK D FRAME D
DESCRIPTION OF WORK I A ~ 4P\. 5Y 5k /Yl .4d~ h j, <l/
I
BUILDING SIZE I sa FOOTAGE I I HEIGHT I
II 1111111 II 11111111 11111 1 ' I 1111 11111 III I 111111 11111 11111 1111 III I I I 1 , ' 1 , 1 1 1 . I ' 1 1 ' 111111 III II I 1 II 1111 II II ' , 1111 II I 11111 III 11111 ' II 11111111111111111 I
50 l/ f3
LOT #
JOB ADDRESS
SUBDIVISION
WORK PROPOSED
(OBTAINED FROM PROPERTY TAX NOTICE)
SIGN D MOVE D
DEMOLISH
OTHER
STEEL
I
D
OTHER I
1$ I
1$ I
1$ I
1$ I
o GAS D ROOFING D SPECIALTY D OTHER
FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA DYES DNO
111I11111111111111I1111111111111111111111111111I1111I1111111111111111111111111I11111111I1111111I1I1111111111I1111111111111111111111111111111111111
0 BUILDING
0 ELECTRICAL
0 PLUMBING
0 MECHANICAL
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
D
PROGRESS ENERGY
D
W.R.E.C.
VALUATION OF MECHANICAL INSTALLATION
I
I
I
I
I
I
I
I
COMPANY I 5/l-c/c..If.~ Ek.c~l4-/C 5Y5~sl
REGISTERED ~ 1 N r FEE CURRENT _ Y / N I I
371/1' iI~~J.~'t.- ,i//4L+ .DAd....J/~y License # Icrc::Joo/CJr?
111111111111111111111111111111111111111I11111111I1111111111111111111111111111111111111111111111111111111I1111111111111111111111111
Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
Attach (2) sets of EngIneered Plans.
....PROPERTY SURVEY required for all NEW construction.
BUILDER
SIGNATURE
COMPANY
REGISTERED
Y/N
FEE CURRENT
Y/N
Address
License #
ELECTRICIAN
SIGNATURE
COMPANY
REGISTERED
Y 1 N
FEE CURRENT
Y/N
Address
License #
PLUMBER
SIGNATURE
COMPANY
REGISTERED
Y/N
FEE CURRENT
Y/N
Address
License #
MECHANICAL
SIGNATURE
COMPANY
REGISTERED
Y/ N
FEE CURRENT
Y/N
Address
License #
OTHER
SIGNATURE
;t{ ~~~J
Address
111111111111111
RESIDENTIAL
COMMERCIAL
SIGN PERMIT
DI~~~tj~~~':' , , , , , , , , , , , . . . , . , . , , , , , , . , , , , , , , . , , , , . , , , , , , , , , . , , , . . , . , . . , , , , , . , , , , , , , , , , , , , , , , , , , , . , , , , , , , . , , , , , , . . , , . , , , . , , . , . . , , , , , , , , , , , , , , , , , , , ,
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (AlC upgrades over $5000)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs Sewers Service Upgrades NC Fences (PloUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to. violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Offici a! for a period not t~ exceed nin~ty ~90) da~s and will demonstrate
justifiable cause for the extension. If work ceases for mnety (90) consecutive days, the\!ob IS conSidered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM ENCEMENT.
FLORIDAJURAT(F.S.117.0:~ '- ,~
OWNER OR AGENT '~7 Y\ ~ CONTRACTOR
Subscribed and swom.t9,(or affirm~d)~re me this S~bscribed and swom t~ Jpr affirmect) be~ore me this
In-3tJ-07 by &V/~ VAl C- LO-<3b-01 by '~'IJv Zk"c..
Who los/are personally known to me or has/have produced Who Is/are personally known to me or has/have produced
Lu.,.5L as Identification. U u"'- SJZ.-. as identificatIon.
Notary Public
Notary Public
- --,:::...... -
-.,......... ---" -'>
Z~-,= :--:~: '_~~- ~L~.,.~ ,= .~=.-= : ~..= .~~~'TJJiE.i~.,-;-
......... - ..-
-~ ......,
_ "'____-..:..0..
- ......---.---
-=L:S.;d _ ::..".~
*,:i...-"~,,"--
FIRE SERVICE USER FEES
Occupancy No.: ~
Plan No,; \}l
Business Name: C;~ .. - <-
Business Address: <"6 !~ ~'Y?Tl- al
Business Phone No.:
Business Fax No.:
Contact:
PLAN REVIEW FEES
B Site Plan NlC
Muili-FamilviCommerciai .06 sf
(Minimum Charge $25.00
o Plan Revisions DBl
SPRINKLER SYSTEMS
B 0 - 25 Heads $50
26 plus Heads $100
STANDPIPE SYSTEM
o Per Riser $50
FIRE PUMP
o Per Pump $100
. FIRE ALARM SYSTEM Cl
~ 0 - 25 Devices ~
U 26 plus Devices $100
SUPPRESSION SYSTEMS
~ Wet $50
Dry $50
C02 $50
Other $50
KITCHEN EXHAUST
o Hood/Ducts
OTHER
B LP Installation per tank
Fuel Tank Installation
(Per Tank)
o Natural Gas Installation
(Per System)
o Spray Booth
Comments:
INSPECTION FEES
N/C
Annual
1 st Re-inspection
2nd Re-inspection
3rd Re-inspection
4th Re-Inspection
(Business closed until
violations corrected)
SPRINKLER SYSTEMS
~ Hydro Undergrounds $45
Hydrostatic Test $65
Acceptance Test $45
Hydrant Flow $75
N/C
$100
$250
$500
per system
per system
Contractor.
Billing Address:
Billing Phone No.:
Billing Fax No.:
Contact:
'-
PERMIT FEE
$50
$50
$50
$50
~
Sprinkler
Standpipes
Fire Pump
Hoods
Fire Alarm
LP Gas
Natural Gas
Fuel Tanks- pertank
Sparklers
Rre Works
Camp Rre
Controlled Bum
Hood/Duct
Place of Assembly
Fire Protection
Flammable Application
Waste TIre Storage
Generator < f<MJ
Generator >30 KW
Bia-Hazard Waste
Fumigation Tenting
Torch Pot/Applied
Haz. Materials
B
$50
$50
$100
$500
$25
$100
$50
$50
$25
$50
$50
$100
150
$100
$50
$50
$100 Annual
~
PERMIT TOTAL!~
{S-V- I
FALSE ALARM FEE
1 st Alarm NlC
2nd Alarm N/C
3rd Alarm N/C
4th Alarm $100
5th Alarm $150
6th Alarm $200
NON COMPLIANCE $150
Annual
Annual
Annual
Annual
FALSE ALARM
TOTALI
$50 ~ Tent 1 0'x1 O' or greater
Rre Pump
Fire Suppression
System Accepiance
B Exhaust Hood/Duct
Re-inspection
(other than annual)
$50 0 Inspection scheduled DBl
and cancelled less than
24 hours
B Construction Insp. NlC
/-\ / Emergency Vehicle ACt ~ /
PLANS TOTAL I;l,. ) J INSPECTION TOTAL L59.
e- FIRE ALARM SYSCi
System Acceptance ~/
Recall A~nce 0
OTHER
~ Rre Wall/Smoke Wall
LP Gas
Natural Gas
$15
$25
$25
per wall
per tank
per system
$50
$50
$50
$50
$15
$45
$30
per tent
$30
DBL
GRAND TOTAL
Date:
lel3' Ie!
/4.;r/"w'1 &v~Aiir
Ins~ctor:
~'-
Zephyrhills Fire Rescue
6907 Dairy Road, Zephyrhills, FL 33542
Fire Marshal
Kerry Barnett
Bus (813) 780-0041
Fax (813) 780-0044
..~'_"_H_'~_~~~<__~>__~_.~_._~__C~_'___~.~~~_________._________~_~__.~~__~~~._.~.___"__,.,_...~_~~
Plan Review Comments
I have reviewed the plans for the alarm installation at 5048 Airport Road in Zephyrhills
and my comments have been placed below. Please contact me ifthere are any questions
with regards to my comments.
1. Calc sheets need on system for the addition of devices. Can be given on final.
Inspections required:
1. Acceptance Test
NOTE: Plans will need to be submitted for alarm installations. Hand sketches will no
longer be accepted.
-.----.t--.-;;;;---- ----T------ ---~. ---,. i"'--" - -. "-.---"~..-l N
----- - -- --- - ----- 1IJ \/ I I (, I (\
[ ,~-~ 1 I J? il f-p ~1-
/ I. ,."
/' i I
I /}___I___/'\______
-.<~
~
~~'cT
,..:r "'-<: I ,
~5 ~I>
~ 1"'0 ,-.
~ ~ . ~
,-. ~ ~ ~.'"
Vl ell ; _ ..:.0_
""l=' ~ __ -..-:...,...~~___ "'"
.., ---- "'
<::> : .
";::;:: ,< 0, <
~.... 1_.,.....,
-~~
....... 0
-"0.. tr.1
--c;;- ~ -g. P-l
~ e:a. '-'
~E~ S
~ Vl
:;s
..-
Vl
'--"
\,
''''''
~J: I
~c
~
~ ~
~. 1\
''1 ""
'" 1\
~ '"' ----
............ I'..
~
'j
"
)-
r-
~
'I !'\
~
"'\
"'-
t:::::~ \Jj
~.
~ ,'\
~... .
"'- I
"'l,\
I r\ "
\ i -",
, 1'\
i .1
I f ::\
i I
I ~
I \\
v.
i
v
~
V ''4' ,
'~",. '
. ....
-----......~-
"
\') ~
n I)
"' ~,s.
~ ~,~
~..
~ ~
~ 1'.
~ ~
'~ ~
~ ~,
~ ...
~ f\
~
~~
~
~'t
~
~.
" 'v\
-.S '\'
V\'~
)- 'K.'
C N
~
1'\
G1
I;
-\
t
~
1'.
""\)
, i
~~.
~
,
~
c:'
'^
("',
::f-
"'0
3:-
~
\I)
~
')-..
r.
'"
( .~"
f
Ii
The FMM-l00 Series is a family of versatile, high-quality,
metal fire alarm manual stations. Single-action or dual-
action models are available. All models come with a key
lock and contain gold-plated contacts to resist
corrosion.
Operation
Single-action
When the bar on the front of the manual station is pulled,
it latches open and is easily visible from 50 ft (15 m).
Reset the activation bar by opening the manual station
with the key and placing the activation bar in its normal
upright position. An optional scored acrylic break rod is
available.
Dual-action
With the dual-action configuration the upper bar on the
front of the manual station rotates inward allowing the
activation bar to be grasped and operated by a single
hand.
~/.""
; i l--'r'~
\B(r=~,
\r&:
-.....__../
BOS,CH
Invented for life
t'
~ f'~'>
.
'l.t"
:t,
_II
Listings and
Approvals:
UL UNIU: Boxes. Non-coded (UL38)
UL UNIU7: Boxes. Non-coded Certified for Canada (CAN!
ULCS528M91)
CSFM 7150-1615: 224
NYC!MEA (382-94-E. Vol. 3)
Compatibility Information
Compatible with all Bosch Security Systems Fire Alarm
Control Panels.
Mounting Considerations
The FMM Series manual stations can be surface
mounted on either the FMM-l00BB-R Surface-mount
Back Box or the FMM-l0QWPBB-R Weatherproof Back
Box. They can also be flush mounted on a standard
single-gang back box.
Note When properly mounted on the
FMM-l0QWPBB-R Weatherproof Back Box,
these manual stations meet UL
requirements for outdoor use.
To comply with ADA standards, the manual station must
be less than 48 in. (1.2 m) above the floor for front
www.boschsecurity.com
wheelchair access and less than 54 in. (1.3 m) above the
floor for side wheelchair access.
Quant.
1
1
1
1
1
Component
Manual station
D102 Key (1358 key)
FMM-100GR Acrylic Break Rod
Hardware pack
Literature pack
Americas:
Bosch Security Systems
130 Perinton Parkway
Fairport, New 'fork. 14450, USA
Phone: + 1 585 223 4060
Fax: +1 800 289 0096
security.sales@Us.bosch.com
www.bo$chs~rity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
56"00 JS- Eindhoyeii. The Netherlands
Phone: +31 402783955
Fax: +31 40 27 B6668
emea.securitysystems@lbosch.com
www.boschsecunty.com
CI Bosch Security Systems 2006/ Data subject to change without notice
F2263916171I CUr: en-US. V5. 26 Jan 2006
Relative Humidity:
Temperature (operating):
90% at +100oF (+380C)
-40oF to + 1500F (-400C to +660C)
Color:
Dimensions (H x W x D):
Material:
Red
4.75in_ x3.25 in_x 1.1 in. (12 cmx8.3cmx2.8cm)
die-cast metal
Switch Rating:
1 Aat30VDCor 125 VAC
FMM-100SA TK Single-action Manual Station (red) FMM-1 OOSA TK
FMM-100SA TK-NYC Single-action Manual Station for FMM-100SA TK -NYC
New York City
FMM-l00DA TK Dual-action Manual Station (red) FMM-100DA TK
Hardware Accessories
D102 Replacement Key
FMM-100BB-R Surface-mount Back Box (red)
FMM-100WPBB-R Weatherproof Back Box (red)
FMM-100GR Scored Acrylic Breakrods
D102
FMM-100BB-R
FMM-100WPBB-R
FMM-100GR
Asia-Pacific:
Bosch Security Systems Pte Ltd
38C Jalan Pemimpin
Singapore 577180
Phone: +65 6319 3450
Fax: +65 6319 3499
apr.securitysystems@lbosch.com
WWW.boschst!curlty.l:om
Represented by
. '~:SlElVl
Il
Selectable Output
Horns, Strobes, and
Horn/Strobes
SpectrAlerr" Advance selectable-output horns, strobes,
and horn/strobes are rich with features guaranteed to
cut installarion times and maximize profits.
The SpectrAlert Advance series of notficaticn appliances is
designed to simplify' installations, vlith features such as plug in
desig,ls, instant feedback messages to ensure correct installation of
indivi,jual devices, an~ 11 field-selectable candela sett:ngs for wall
and c'iling strobes and horn/strobes.
\i\ihen installing Advance products, tht attach a universal mOclnting
plate to a four-inch square, four-lIlch octagon or double-gang
junction bo),. The two-vvire mounting plate attaches to a single-gang
junction box.
r~ext. connect the notification appliance circuit 'Niring to the SEMS
terminals on the mounting plate.
Finally, attach the horn, strobe or horn/strobe to the mounting plate
by inserting the product's tabs in the mounting plate's grooves. The
device will rotate into position, locking the product's pins into the
mounting plate's terminals. The de'./ice will temporarily hold in place
with a catch until it is secured with a captured mounting screw.
The SpectrAlert Advance series includes outdoor nocfication
appliances. Outdoor strobes and horn/strobes (two wire and four
wire) are available for wall or ceiling. Outdoor horns are available for
wall only. A.II System Sensor outdoor products are rated between
minus 40 de::jrees Fahrenheit and 151 degrees Fahrenheit in 'Net or
dry applications
SPECT~
A...a....x...A..~.Ji~.'i
Features
. EleCTrically compatible With existing SpectrAlen products
. Automatic selection of 12- or 24-volt operation at 15 and 15/75
candela
. Plug-in design
. Field selectable candela settings on wall and ceiling units: 1 S, 15/75,
30, 75,95, 110, 115, 135, 150. 177, 185
. Same mounting plate for wall- and ceiling-mount units
. Shorting spring on mounting plate for continuitv check before
installation
. Tamper resistant construction
. Outdoor wall and ceiling products rated from -40QF to 151 OF
. Design allows minimal intrusion into the back box
. Hem rated at 38+ dbA at 16 I/olts
. Rotary switch for horn tone and three volume selections
. Outdoor products UL listed to UL 1638 (strobe) and UL 464 ('lorn)
outdoor requirements
. Outdoor products rainproof per UL 50 (NEMA 3R)
. Compatible with MDL sync module
Agency Listings
S11111AU11&
@
LISTED
<8>
APPROVED
MEA
approved
I ;:::,:i:&~~
. "~/'-.15~-::;~..(
SpectrAlert Advance Specifications
rn~1rrmJi1r~iW,f1?~iJl!JItl... .1.... ....._.........~..lrIlttll'!'~IIRI_M~....~~~j
(:;- .,~-':.~(
SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x ]'/'-inch back box, 4-inch octagon back box or double-gang back
box. Two-wire products shall also mount to a single-gang 2 x 4 x 1 '/.-inch back box. A universal mounting plate shall be used for mounting ceiling and wall
products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products. when used with the
Sync-Circuit'" Module accessory, shall be powered from a non.coded notific3tion appliance cirCUit output dnd shall operate on a nominal 12 or 24 volts. Whe"
used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification
appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit
from a regulated DC or full-wave rectified, unliltered power supply. Strobes and horn/strobes shall have held.selectable candela setlings including 1), 1 'on), Jt),
75,95, 110, 11 5, 135, 150, 177, 185,
The strobe shall be a System Sensor SpecuAlert Advance Model_listed to UI. 1971 and shall be approved for fire protective service. The strobe shall be
wired as a primary-signaling notiilcatlon appliance and comply with the Americans With Disabilities Act requirements lor visible si'~nallnq applidrlles, flashing al
1 H7 over th" sw.be's entire operating voltage range. The strobe light shall consist ofaxenon flash tube ;Jnel assoCiated ipn'/rpf1ector system
,1 . -, i ~" I '''"_
The horn/strobe shall be a System Sensor SpectrAlert A.dvance Model _listed to UI. 1971 and UL 464 and shall be approved for fire protective serVTe
The horn/s1:tobe shall be wired as a primary-signaling notification appliance and comply with the Amencans With Drsabilities Act reqUirements for visible
signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage lange. The strobe light shall consist of a xenon flash tube and associated
lens/reflector system.; he hom shall have three audibility options and itfl OplOfltO SWitch betweefl a ternporalthree-pallern and a norHempordl (cofltiIlUOllS)
panern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder The hom em
horn/strobe models shall operate on a coded or non-coded power suppiy
SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by lIL and shall operate between minus 40 degrees and 151
degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths Inch cOflduit
entries.
The module shall be a System Sensor Sync-Circuit model MOL listed to lIL 464 and shall be approved for fire protective service. The module shall synchronize
SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the homs on horn/strobe models oller a
single pair of wires. The module shall mount to a 4"/'6 x 4"/'6 x 2'/.-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z
[class A) circuit. The module shallsvnchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they
control. The module shall not operate on a coded power supply.
~~~~.,Jj,"._U.I.I__II.__!l".!~~~~
:I""1"I'IOI,,,,"inl;Tfl.'Ptld1dl' 320Fto 1200F [0.Ct0490C)
V, S>:r;€:, ();)?~'?:t '-,q TCn11Y'::?;;itIJ' - _4QoF to 1510F (-4QoC to 660C)
~{i.-;i-':""i:rji1y n-J~'~-;
;.'::,:1:; (""-~f1~'~',l- ";~';:~-~'i''''~. ~,~I ~-..,:- ;"~'ri{ ~"'n~' ~i~-l:"".~";~~"'C-
~.'i, r:;;~~.
10 to 93% non-condensing (indoor products)
1 Rash per second
Regulated 12DC/FWR or regulated 24DC/FWR'
8 to 17.5 \I (12\1 nominal) or 16 to 33 V (24 nominal)
12to 18AWG
6.8- diameter x 2.5 - high (173 mm diameter x 64 mm high)
5.6-L x4.7'W x 2SD (142 mm Lx 119 mmW x 64 mm D)
5.6"L x 4.7'\'11 x 1.3-0 (142 mill Lx 119 mmWx 33 mm D)
59'L x 5.0'W x 2.2-0 (1 5 I mm Lx] 28 mm W x S6 mm D)
/"1- diameter x L25"'high (180 rmn diameter x)l rmn high)
5rl. x 51"Wx 2.0'D (145 mm Lx 130 mmW x 51 mm D)
71"' diameter x 20" high (180 mm diameter x S 1 mm high)
~<~rn!>" F!;~':;~ f~,T\'~
\,",1. _',;;"
C"""?~'0t~~\<~ \f~';1~}, '..:;"" P~n~c--
t'~r~:d -~,~'~nv:';-""
,'jt,.
( ~'t!;~~~~ T",H)\!r',t r '-~-~":'ns;n~;.:.: (>ncjljd;nl:~ t-:-n:'
-en'- -I>"
: :; i ,~:,) i i . _ i ; , ~ <~
~,i'--"l dF~'~~'.~":~"(l;~
i~,...! _'-''I0,\r1 h:::r!.' :~~,.. ~~,,;~~ ,,--.I':',~r"~~:-'.,-~'-p
r r';"n,'"!-!~h~'I,t:'lt tt;1(!<: [.10.. (,yl' ~ r!u-p;nn:::rrw"
(_Pi!l"\ l:--.q"'.!i (f . ';J,n;,p: ~" :~nf i 1,~r. ~~. ; !!"- '{!111--" !-,.;C' I. . ;1::,. i,'i,fp:n
'.1'"
1. Full Wave Rectified (FWR) voltage is a non.regulated, time varying power source that IS used on some power supply and panel cut puts.
2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd
l.'J~,-039~,-QG3
SpectrAlert Advance Dimensions
5.98-
5.05-=1
1\ "- ..... ~ .I -' J
2.5"
1
1'.';...!! -<',.;:>1 h"H J ';'C:"~! t.;",
SpectrAlert Advance Ordering Information
~~~\i~\fiW\'-_it~URi(~
t>~~
oWo
'00 ocJ
@
l;<'f._~~! h;-..-';" ~"'''''~
'-;;.:Yif\': L:_\/:J' ~"r'v ,;:t_;,~
P2R*.
P2RH'
tV~~:t 1,.1..-" .~i"'~?f,.h,.',
P2RK'
P2RHK'
P2W'
P2WH*
P4R*
P4RH'
P4RK
P4RHK
P4W'
P4WH*
2.wire HOin/Strobe, Standard cd', Red
2-wire Horn/Strobe, High cd, Red
2-wire Horn/Strobe, Standard cd. Red, OutdoOi
2-wire Horn/Strobe, High cd, Red, Outdoor
2-wire Horn/Strobe, Standard cd, White
2-wire Horn/Strobe, High cd, White
4.wire Horn/Strobe, Standard cd, Red
4-wire Horn/Strobe, High cd, Red
4-wire Horn/Strobe, Standard cd, Red, OutdoOi
4-wire Horn/Strobe, High cd, Red, Outdoor
4.wire Horn/Strobe, Standard cd, White
4-wire Horn/Strobe, High cd, White
r....~";;\~~Jiiiiali;m~~....
lj,;;~ '. .. . _ ... __"." . ..'." .c,..._,.. . .'~ . . ..~._ .._......""'"
,",,-,;l;,- .... ~jn;~', '';;'~~!.h,,,,- ~'-r,,":'!~
PC2W'.
PC2WH*'
PC4R
PC4RH
PC4RK
PC4RHK
PC4W
PC4WH
2-wire Horn/Strobe, Standard cd, White
2-wire Horn/Strobe, High cd. White
4-wire Horn/Strobe, Standard cd, Red
4-wire Horn/Strobe, High cd. Red
4-wire Horn/Strobe, Standard cd. Red, Outdoor
4-wire Horn/Strobe, High cd, Red. Outdoor
4-wire Horn/Strobe, Standard cd, White
4-wire Horn/Strobe, High cd, White
(~ r~!
SCR"
SCRH*
SCRK
SCRHK
SCW"
SCWW'
'; ....' -, :: ~: ".. f" ~.,.-..
SR"
SRW'
SRK
SRHK
SW'
SWH*
Strobe, Standard cd, Red
Strobe, High cd, Red
Strobe. Standard cd, Red, Outdoor
Strobe, High cd. Red, Outdoor
Strobe, Standard cd, White
Strobe. High cd, White
Strobe. Standard cd. Red
Strobe, High cd, Red
Strobe, Standard cd, Red. Outdoor
Strobe, High cd, Red. Outdoor
Strobe, Standard cd, White
Strobe. High cd, White
HR
HRK
HW
Horn, Red
Horn. Red, Outdoor
Horn. White
'.~.; ,
PC2R'
PC2RH*
PC2RK
PC2RHK
2-wire Horn/Strobe, Standard cd. Red
2-wire Horn/Strobe. High cd. Red
2.wire Horn/Strobe, Standard cd. Red. Outdoor
2-wire Horn/Strobe, High cd, Red, Outdoor
BBS-2
BBSW-2
BBSC.2
BBSCW-2
,~.,t ,', '."
Back Box Skirt, Wall, Red
Back Box Skirt, Wall, White
Back Box Skirt, Ceiling, Red
Back Box Skirt, Ceiling, White
, Add "-P"to model number fOi plain housing (no "FIRE' marking on cover), eg, P2R.P
t Add ".SP"to model number for "FUEGO" marking on cover. e.g, P2R-SP
:10 "Standard cd: refers to strobes that include 15. 15/75,30.75,95, 110, and 115 candela settings. "High cd;' 'elers to strobes that include 135, 150, 177. and i 85
candela settings.
All outdOOi units ending in "K"include a weatherproof back box.
(~:;::.~::
~",,",,"'i.'
~C""lil\.,?'.~~:.:;t "~'" ~'-'... ~ ,r.;:
...." '':;:' D' !l;::e ~ I'
fI.:';,r:"f!Il:.cfiC; f"10
~~ ~,"'. 1'\"'"""'-# ~.'.t ~,
3825 Ohio Avenue. St. Charles, IL 60174
Phone: 800-SENSOR2 . Fax 630-377.6495
~2~J06 :';ysterr Ser:;o'
Pr:Jdud SL<oofil..3\IQ' S suL'I~:.:t Ie U1ilnge wil'~,ul notlLt> '.~:;lt svs'en''''''5or. :c,n 'Of
C.I"erl. C'odJL' irfO',ratior. irll.Jdirg th," idte:.'. ....:'sit:r ofths dil'.d ~h:!:<
f.~5-0~95-'J'J3 . l:1f!)f:. '1676
UL Current Draw Data
~111D~ MD!i~;~~."
.;~; __S '1/ni\",
\.; - ~3 \/nH",
\",ci ( h..l t~ (::I
~\;:. r~
:::'dUi:d "'"dt'.:;:(li
L) l~
75
f\i.iii
J :.5 ':/d!',
j~ _,_. ;.:,d'
f","'\/h
i. ~\ \_
I, 'J I,
15' 123 128 66 71
15175' 142 148 n 81
30' NA NA 94 96
75' NA NA 158 153
95' NA NA 181 176
110 NA NA 202 195
115 NA NA 210 205
135 NA NA 228 207
':'""'1" 150 NA NA 246 220
177 NA NA 281 251
185 NA NA 286 258
~~~'~~.!l.,ltJJffu~1IlItl
'.~ l ...,:' 'I ; :\:.:~ ;
Temporal
Temporal
Temporal
Non-temporal
Non-temporal
Non-tempolal
Coded
Coded
Coded
High
Medium
Low
High
Medium
Low
High
Medium
Low
57
44
38
57
42
41
57
44
40
55
49
44
56
50
44
55
51
46
69
58
44
69
60
69
48
75
69
50
so
69
56
52
?5
69
50
; n.. >_)~,,,"dC".
i;':'"l'; (-. ;,."
Temporal High 137 147 79 90 107 176 194 212 218
Temporal Medium 132 144 69 80 97 157 182 201 210
Temporal Low 132 143 66 77 93 154 179 198 207
Non-lemporal High 141 152 91 100 116 176 201 221 229
Non-temporal Medium 133 145 75 85 102 163 187 207 216
Non-ternpolal Low 131 144 68 79 96 1u 182 201 210
~O
; :'1-' ~,,.
Temporal High 136 155 88 97 112 168 190 210 218
Temporal Medium 129 152 78 88 103 160 184 202 206
Temporal Low 129 151 76 86 101 160 184 194 201
Non-tempolalHigh 142 161 103 112 126 181 203 221 229
Non-temporal Medium 134 155 85 95 110 166 189 208 216
Non-temporal Low 132 154 80 90 105 161 184 202 211
'''''':''''~..l''..~~~:%c':i\lI'~-"'m:"",!~~_~~~~~,,"~~~~1I~1-~,;;~.i't4:!l',"'~-"JjI;~~)"M~1ii\;i':1l.~1
IW'jl;f,!.>\~i~W.HJ,;_~,~~~!I~Ji~~:millt<,w.tl;o;:r;,';;l".lE:JJ.--";~l~t;t!,;:J,Wli5tS.i;';!ii'i.!o3:"'j<J,~.Ii~~~~
Lh H\)..qi~ ;.":'.;./ ,\--/-: j.-', :~-"
Temporal High 245 259 290 297 Temporal High 215 231 258 265
Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258
Temporal Low 232 251 282 292 Temporal Low 207 221 248 256
Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 2131
Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267
Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262
Candela Derating
For K series products lIsed allow temperatures, listed candela
ratings must be reduced in accordance with this table,
~..
A ~ ,(~_~" ~@F':'~~;,~""':$..lii.i~,4;"".,t...l.:i-~ ".31o*t!'~~~
l b((':(ll ~'.n(i(.~:~, l...3-il;iela t(;:tF~'~! ;:-.t --Q'4IFf
15
15/75 Do not use below 320F
30
75 44
95 70
110 110
115 115
135 135
150 150
177 177
185 185
.. \f;'j',
\:. -:'~~r~::,p ,.
1 Temporal High 78 78 84 84 88 88 99 98
2 Temporal Medium 74 74 80 80 86 86 96 96
3 Temporal Low 71 73 76 76 133 80 94 89
4 Non-temporal High 82 82 88 88 93 92 100 100
5 Non-temporal Medium 78 78 85 85 90 90 98 98
6 Non-temporal Low 75 75 81 81 88 84 96 92
7 Coded High 82 82 88 88 93 92 Wi 101
8 Coded Medium 78 78 85 85 90 90 97 98
9 Coded Low 75 75 81 81 88 85 96 92
'5ettings 7, 8. and 9 are not available on 2-wire horn/strobe.