HomeMy WebLinkAboutVECTOR SECURITY . VECTOR SECURITY National Accounts Division, 10642 Wakeman Court, Manassas, Virginia 20110 · (703) 369-1444 · FAX: (703) 369-6079 . FIRE SYSTEM LOWE'S #1854 7921 Gall Blvd. Zephyrhills, FL 33541 t> 4-f.m.,-i- ~ ~ ~u COMMERCIAL FIRE & COMMUNICATIONS INC. P.o. Box 1350 LARGO, FL 33779 (727) 530-4521 FAX (727) 531.0596 License #EF0000785 [18LFLF8~ @~ LF~[m~~DLFLF&[1 DATE TO ~tt-c,\ 0-+ -2-epVtlurh7H \ RE: o Shop drawings o Copy of letter o Prints o Change order o Plans o Samples the fOllowing items: o Specifications WE ARE SENDING YOU > o Attached o Under separate cover via o DATE COPIES NO. DESCRIPTION 3 \ , THESE ARE TRANSMITTED as checked below: o For approval o For your use o Approved as submitted o Approved as noted o Resubmit copies for approval copies for distribution o Submit o As requested o Returned for corrections C Return corrected prints > C For review and comment o o FOR BIDS DUE D PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: /" iJ J.. K {{)(' ~'h.ti~~ If enclosures are not as noted, kindly noti~ ~ Radionics. Lowe's #1854 Zephyrhills, FL D9412 Battery Calculation Worksheet (current values will be expressed in mAl Calculations for 12 VDC Devices only Instructions: fill in shaded data fields 11/15/2004 350 500 350 500 106 206 0 0 2.4 30 2.4 30 48 48 48 48 20 320 20 320 26 50 78 150 1 70 0 0 0 50 0 0 22 147 0 0 22.34 23.39 0 0 12 45 0 0 Module 120 350 0 0 106 206 212 424 106 206 0 0 20 75 0 0 50 50 0 0 5 54 10 108 0.5 0.8 31 49.6 22 36 0 0 100 120 0 0 14 45 14 45 0 0 0 0 0 0 0 0 0 0 0 0 0 0 765.4 1674.6 0 0.06 0 0 5 35 25 25 0 0 0 0 30 60.06 Calculation TOTAL BACKUP BATTERY PROVIDED: 28AH BOSCH 07038 POWER SUPPLY BATTERY CALCULATIONS Project: T'-'" ""_U'- "._, , .~~-:~;! Date: Prepared By: i'F ..')~ Rev. 5-4-04 BOSCH 07038 POWER SUPPLY BATTERY CALCULATIONS Project: ' Date: Prepared By: .--.,. IIOOlllllBllrlliiU ~'l<^ ""', Rev. 5-4-04 CIRCUIT CONFIGURATION Project: ,." Oate:- ,..",' J --li.I~_I._ Prepared By:-&----. -"'-IIJII.IIII'111ll1l; RAOlONICS 07038 PANEL Bosch DAS24-VARC-SWR Multi @ 75cd Wall Ham/Strobe Bosch DS-VARC-SWR - Multi @ 75cd Wall Strobe CIRCUIT CONFIGURATION Project: !'f,-.'" .,-,:.:~. --..'i,.~' lit. Date: Prepared By: II _.".'c~_.~. ~ti~ RADIONICS D7038 PANEL Bosch RSS-24MCC-FR - Multi @ 95cd Ceiling Strobe Bosch DAS24-VARC-SCR - Multi @ 95cd Ceiling Horn/Strobe CIRCUIT CONFIGURATION Project:" " D t '. r - 'i~1lIltIIIII a e.J<,._,L;._. <' <. <.<<. . <<~ < Prepared By: -< >_'''~A_.<-.tJlI'~ RADIONICS D7038 PANEL Bosch RSS-24MCC-FR - Multi @ 95cd Ceiling Strobe Bosch DAS24-VARC-SCR - Multi @ 95cd Ceiling Hom/Strobe Bosch RSS-24MCC-FR - Multi @ 95cd Ceiling Strobe Bosch DAS24-VARC-SCR - Multi @ 95cd Ceiling Horn/Strobe CIRCUIT CONFIGURATION Project: ,T /'" Date: 't g Prepared By: II~"'" . . -. ',.,' '" '-' ' .':&;:~~ RADIONICS D7038 PANEL CIRCUIT CONFIGURATION Project:" - "",11', Date: Prepared By: -~<-, -- --_...:~~_~ RADIONICS D7038 PANEL CIRCUIT CONFIGURATION Project: . Date: Prepared By:IITe_'-_....~'~..~\.:~ RADIONICS D7038 PANEL Bosch RSS-24MCC-FR - Multi @ 95cd Ceiling Strobe Bosch DAS24-VARC-SCR - Multi @ 95cd Ceiling Horn/Strobe CIRCUIT CONFIGURATION Project: ,"'> , Date: ,'I ~~'-i,i!"W.l'K-""-'-"'-j 11 ~~l.I~;",R!iIIiy~ Prepared By:-n"'.'..__.'"-;~~~ RADIONICS D7038 PANEL Bosch RSS-24MCC-FR - Multi @ 95cd Ceiling Strobe Bosch DAS24-VARC-SCR - Multi @ 95cd Ceiling Ham/Strobe CIRCUIT CONFIGURATION Project: D t .~~~::;;~/.~~l'l a e. ~,,,,~,,",~.~ ,,_ < In= Pre ared B :Tr'~-- ~'-----~1'i~~l~ P Y ., ,<<.;"l:Z',<,~ RADIONICS D7038 PANEL D9412G/D7412G Control/Communicators Specifications Control Features . Eight programmable areas, each with perimeterlinterior partitioning. Regular, master, associate, or shared option by area . Real-time clock and test timer . Up to 1000-event log, including time, date and event with area, point and user number . Battery charging circuit; AC power, voltage and ground fault supervision . Automatic reset circuit protectors . On-board CPU watchdog waming buzzer and diagnostic LEOs . Lightning and EMI protection . Power limited external circuits Communicator . Built-in digital communicator with phone line monitor (loop or ground start) . Multiple telephone numbers, primary and duplicate paths with main and alternate destinations . All reports within each 4 route groups are programmable . Optional dual phone line switcher monitors 2 phone lines . Automatic test and status reports . Time windows for arming and open/close report suppression . Programmable answering machine work-around for remote programming on shared phone line Programmable Outputs . 2-amp alarm power @ 12 VDC . 1.4-amp aux power @ 12 VDC . 4 alarm output patterns . Automatic bell test . Programmable bell shut-off timer . D7412G: 67 programmable outputs . D9412G: 131 programmable outputs System Response . D7412G: 75 points, 8 on-board, up to 67 off-board . D9412G: 246 points, 8 on-board, up to 238 off- board . 31 custom point indexes, including fire supervisory . Selectable point response time . Fire alarm verification . Fire inspector's local test . Watch mode . Scheduled events (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door access and more User Interface . Supervises up to 8 command centers (up to 32 non-supervised command centers can be used) . Custom command center text . D7412G: 4 custom functions . D9412G: 16 custom functions . Full function command menu including custom functions . D7412G: 99 Users . D9412G: 249 Users . Each user has authority by area and 16-character name . 14 custom authority levels control user's authority to change, add, delete passcodes or access control tokens/cards, disarm, bypass points, initiate system tests, and more . Adjustable brightnesslloudness for command center displayl sounder . D7412G: 1 parallel printer . D9412G: 3 parallel printers Access Control . D7412G: 2 access control doors and 396 tokens/cards . D9412G: 8 access control doors and 996 tokens/cards . Custom door strike, point shunt and auto disarming response by area . Logging options for: Access Granted, No Entry, Request to Exit and Request to Enter . 14-panel wide access levels with both manual and scheduled control $ radlonics A member of the Bosch Group D9412G/D7412G System Description D~9412GID7 412G Control/Communicators provide an integrated solution to Access Control, Security, and Fire Alarm System applications. Control/Communicators are capable of monitoring alarm points for intruder or fire alarms while operating user command centers, (access readers, door locks- D7412G1 D9412G), and other outputs. Includes a built- in digital communicator, which reports events to selected destinations via 4 programmable route groups. Programming and accessory modules offer flexibility and beneficial features rarely found in other security control systems. Area Conftgurations D9412G1D7412G area programming offers you a wide selection of different system configurations. Each area is; assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master/associate). User Interface D9412G1D7412G command centers provide on- premises point and system status annunciation. A fully selectable user interface can customize command center displays and simplify operation by creating menu items and functions, appropriate only to that command center. Function Lists can help a user become familiar with the clperation of the control panel. Custom functions allow users to perform complex functions with a few keystrokes. Each may be programmed and identified by 16 characters of custom text and contain up to 32 keystrokes. D1255 Command Center, D1256 Fire Alarm Command Genter and D1257 Fire Alarm Annunciator use a 16- character English language display to show system status, area status (custom text), and point status (custom text). D720 8-point LED area command center provides command functions and annunciation for up to B points in a single area. Any combination of these <:ommand centers may be used within the same area. Easy to remember commands like Command 1, Command 2, and Command 8 make an easy transition for seasoned Radionics users. User Passcodes D9412G1D7412G can accommodate: I. D7412G: 99 user passcodes D9412G: 249 user passcodes. (Each passcode individually programs with 3 to 6 digits in length and no fixed digits). lEach user is assigned one of 14 customized authority Ilevels in each area. You may restrict passcodes to operate only during certain times. Each user may have a 16-character customized name that may be viewed, printed, reported to a central station in Radionics' Modem IIli Communications format or retrieved with Remote Account Manager (RAM). Security and Fire Detection D9412G/D7412G provide eight .on-board" detection points, and up to 238 additional off-board points (depending on Model and expansion interfaces). Points may be individually programmed and used to monitor all types of burglar alarm, fire alarm, and supervision devices. Communications D9412G/D7412G have four route groups, sort reports by priority and are capable of transmitting reports to up to four locations. Each group has a programmable primary and backup destination. Compatible with D6600 NetCom Communications System using a D9133TTL-E Ethemet Interface Module. Radionics' Modem II1a2 Communications Format, available with Radionics' receiver, adds these reporting capabilities. To name just a few: . Individual point numbers and text . Opening/Closing reports by area number . Remote programming attempts . Diagnostic reports . Access control events with user name Event Log Storage, Viewing and Printing D9412GID7412G event log automatically stores up to 1 000 events. All local and transmitted events are stored (some access events are selectable). Event log includes time, date and event, with area, point and user number. Users may view event log from Alpha Command Centers. Events may be retrieved remotely using RAM. Events are printed as they are stored in event log. D9131A Parallel Printer Interfaces can be installed to record events locally on one, two, or three printers (depending on model). Each can print opening and closing, access, alarm, Skeds, or any combination of events. Each can print information from any combination of areas. Each can supervise various printer status conditions. Event log and local printer are ideally suited for customers who like to have a record of openings and closings without having extra communications costs. Logger and RAM, can suppress reports and then retrieve events periodically using one phone call, rather than receiving several calls each day. When the panel's event log reaches its programmed threshold of stored events, it can send a report to a receiver to remind central station to retrieve events from the panel's event log with RAM. D9412G1D7412G Specifications Page 2 47487B @ 2001 Radionics D9412G/D7412G Scheduled Events (Skeds) D9412G1D7412G internal clock and calendar help the panel operate individual scheduled events (Skeds). Skeds perform a specific function (such as arm/disarm, relay control. point bypassing, etc.). Each Sked is programmed for a time and day-of-week schedule or a date-of-year schedule. Users may change Sked Time if programmed for local time editing. Holiday schedules can enable or disable individual Skeds during holiday periods. . 64 scheduled events with up to 26 different functions . Day-of-week or date-of-year schedules . Four holiday schedules of 366 days each (leap year) Fire Test D9412G/D7412G Fire Test Mode suppresses reports to the central station receiver so you can test initiating and indicating devices without transmitting alarms. Initiating Fire Test Mode, sends "Fire Walk Start" to central station indicating start ottest. Test events become "local only.. Command center shows how many points are to be tested. Each time a device initiates an alarm, programmed point text displays at command center and the fire bell rings for 2 seconds. Automatic sensor reset feature allows continued testing of devices without time consuming trips to manually reset sensors. At the end of test, command center displays the number of untested points. You can also view point text for each untested point. Ending Fire Test Mode, sends "Fire Walk End" to the central station receiver indicating end of test. Combining Access Control with Security and Fire Detection (D7412G/D9412G) D9412G1D7412G combined systems can help prevent false alarms making it easy to use one system that controls access, security, and fire functions. Access control features of D7412G/D9412G can deny access during armed periods, grant access only to certain authorized users depending whether an area is master armed, perimeter armed or disarmed. Alarm system can automatically disarm when designated authorized users are granted access. . D7412G: Two (2) access doors; 75 detection points; 396 T okenlUsers . D9412G: Eight (8) access doors; 246 detection points; 996 T okenlUsers 092108 Access Control Interface Module Access is granted from Wiegand format readers or Request to Enter/Exit devices when connected to the D9210B. Also provided are connections for door point. strike, buzzer and enclosure tamper. (One D9210B required per door). . Each access door can be configured independently . Door point controls access door and is part of alarm system (door does not need double contacts) . Door contact can reset strike time when opened . Door contact can terminate entry buzzer (if used) . Door contact is shunted when valid access is granted . Optional buzzer can trigger prior to end of door shunt period, warning user a "door left open" condition is about to occur . Door point can be configured to generate alarm or trouble (or have no response) when door is left open beyond shunt period . In addition to granting access, cards control whether system will disarm along with granting access . Door strike can release automatically during disarmed periods, then automatically re-Iock when area is armed . Door can generate an alarm, trouble, (or have no response) depending on area's armed condition when door is opened outside authorized access period . REQUEST TO ENTER and REQUEST TO EXIT can be programmed to shunt door without activating strike . An option determines whether access granted, no entry, request to enter, or request to exit messages are sent to event log RAM IV and RAM IV Lite These account management and panel-programming utilities allow computers equipped with the Microsoft"" Windows4!l operating system and a modem to act as a remote programming, record storage, remote control and troubleshooting tool for the D9412GID7412G ControVCommunicators. To enhance the down/upload capabilities RAM can be used in a TCPIIP and Dynamic Host Communication Protocol (DHCP) configuration. D9412G1D7412G Specifications Page 3 e 2001 Radionics 47487B D9412G/D7412G Specifications General Gontractor shall fumish and install, where indicated on plans, a Radionics D9412GJD7412G Gontrol/Communicator. Panel shall be listed by Underwriters Laboratories for NFPA 72 Applications. D9412G1D7412G shall support initiating and indicating modules and Radionics Command Centers. Power supply shall provide 1.4-amp @12 VDC for all processing functions and auxiliary requirements. Software D9412GJD7412G programming of all system functions shall be accomplished on site using Radionics' Hand- held D5200 Programmer or remotely using a RAM software package. A programmable system passcode shall be used to prevent unauthorized remote programming. Panel shall accommodate up to four separate telephone numbers for primary, a1temate and backup receivers, automatic test reports, selective relay activation, and c:ustom text on associated command centers and annunciators. When resetting alarms, arming or disarming a c:ombination firelburglary and/or access control system, lhe user shall be identified by name and number. D72121D7412G: Up to 99 users D91121D9412G: Up to 249 users Panel's intemal clock shall support Skeels (scheduled events) feature. User shall have option to alter Sked ,:activation times using a programmable passcode. Up to 64 programmable, scheduled event functions shall be available for controlling relays, enabling passcodes, windows, and supporting service alert feature. Other programmable functions shall include fire alarm Ireset commands, and day/dateltime adjustments. Event Logger/Clock D9412GJD7412G event log shall store up to 1 000 events. All system events shall include time, date and event with area, point and user number. Access events (optional) stored shall include: Access granted, No Entry, Request To Enter, and Request To Exit. Logger records certain functions entered at command centers. Stored events in Logger shall be retrievable with a RAM software package. Remote Diagnostics and Controls D9412GJD7412G shall be able to be remote controlled through use of RAM software. Features shall include: reset of audible signals, activation/deactivation of D8129 relays, interrogation of battery, point and armed status, enabling or disabling reporting functions, and shunting of reporting points during servicing. Command Centers D9412GID7412G command centers shall be Radionics D1255 Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator. Each shall D9412G/D7412G Specifications Page 4 @2001 Radionics be equipped with a 16-character alphanumeric display, distinct fire and burglary tones, and backlighted multi- key touchpad. D1255, D1256, and D1257 shall have the ability to display for each detection point: alarm, trouble, supervisory, or faulted, and custom text. In addition, expanded, addressable point displays shall include missing and extra point information. System-wide displays shall include: local system test, sensor reset, fire test mode, and user programming prompts. Fire Test D9412GJD7412G Fire Test Mode shall support single- person operation. All reports to central station shall be suppressed while fire test is being conducted. Fire Test Mode shall be activated by entering a user passcode at a command center. All testing data shall be visible on command center and annunciator displays during testing. Hardware D9412G1D7412G shall provide up to 246 individually identified addresses, (75 with D7412G). Each shall accommodate normally open and/or normally closed devices with end-of-line resistor supervision. Each point shall be programmable for fire, fire supervisory or burglary applications. Point output shall be silent or audible. Audible output shall be steady, pulsed, CA standard, or temporal code 3. External Hardware D9412GID7412G shall allow use of up to three on-site parallel printers (one with D7412G), using Radionics D9131A Printer Interface Modules. Events shall print time, date, and event description with area, account, point, and user number, including text for points and users. Installation, Warranty, and Training D9412G/D7412G System Installation, wiring of initiating devices and signaling circuits, shall be the responsibility of installing company. Warranty on all components shall be two years, subject to manufacturer's limitations. Training on complete system operation shall be furnished by installing company upon completion of installation. 47487B D9412G/D7412G Accessories/Ordering Information '" ' "' , ", ">~~;~~~~..~- ~ ' x ..,,~~ ",' 11'~'M''''\ v ,~~~,-;r'::'~1':~:;J "' " -" ,.--- "._.~ ~ ~ D1255 Command Center D1256 Fire Alarm Command Center D1257 Fire Alarm Annunciator D720 8 Point LED Area Command Center D268 Independent Point Control Module D269 Independent Point Control Keypad -~~~--- _u_ ~~.__.- -~-_..~.._"-_._..,.,"._..,,.- -- --------- D279 Independent Point Control D548 Command Center Flush Mount Kit, Brass D54C Command Center Flush Mount Kit, Stainless D55 Command Center Desk Stand D56 Command Center Surface Mnt. Conduit Box ~'C " . ~ ,- T~'"'_ ~ q ~':"'~: .".::::_ D8125 D9127UIT D8128C D940 D8129 D127 D136 D8121A D8122 D9131A D92108 POPEX Module POPIT Module, U=No Tamper 1 T= Tamper OctoPOPIT Module Super Loop Module OctoRelay Module - -"^-~----_._----- Reversing Relay Plug-in Relay Derived Channel S.T.U. Non UL Derived Channel S.T.U. UL Listed Parallel Printer Interface Module Access Control Interface Module ZX835 r ~~'" _,..~c~~"',,"~"""'_ -~ <.~ .:'",~ I-J ::.. ~~ ZX970 ZX935Z ZX776Z ZX794 ZX938Z D278S D298M D298S PIR/Microwave Detector, 35 x 35 ft. (10.7 x 10.7 m) PIRlMicrowave Detector, 60 x 60 ft. (18.3 x 18.3 m) PIR Detector, 35x 35ft. (10.7x 10.7 m) PIR Detector, 50 x 50 ft. (15 x 15 m) PIR Detector, 90 x 90 ft. (27 x 27 m) PIR Detector, Ceiling Mount, 360. x 60 ft. (18m) Smoke Detector Base 12 VDC Smoke Detector Base, Master, 24 VDC Smoke Detector Base, 24 VDC ",., ' . " . ''''i'',' ',,,,",,""'" >, 1'~~"~1l!""''''''<'-''''''#'f,\~,'''''''''''ID>~ k. . - ?~" ~ .".'~a" ." ,+ ~;fi~~v~:>$~:~~5}~,j~'~~~~~~r1?~i~~~. . , ,. " , ,. -' .' ' " '~d!l"~~"" " "".j."'fI ~ ,'{~~~ .~,~~~~~,~~ >."0 ~'=.: ~~~.~..L~~~ D125B D129 D130 D184 D185 D192C I, D192D D928 D8130 Dual Class B Powered Loop Interface Module Dual Class A Initiation Circuit Module Auxiliary Relay Module, 12/24 VDC Auxiliary Local Energy Interface Kit Reverse Polarity Interface Module NAC. Module, Class B, 12/24 VDC, 1.8-amp --"----_._-~--~ ------------..----- NAC. Module, Class NB, 12/24 VDC, 3-amp Dual Phone Line Switcher Release Module ". ~' .' '<" "'''F " " .'" .~.., . - .~- 'C'i'lf<Y"'. ;f~ .~, " ,/,,_.~,'Ij":~ t ~ 0)$ ,~~ ~ _~,~.f ~~\,~,,':.:,,"4, .,--1'~';<:;~;1if~',e:p'l~fii!i! ~: ~ .L_~ " _~_i_..E..~~l..i~~~~~~~~~~~~'>;.{~<~ D9142F D8132 D1640 D113 D122/L D126 D1218 Auxiliary Power Supply, 24 VDC, 4-amp Battery Charger Module, 12 VDC 16.5 VAC 40 VA Transformer Battery Lead Supervision Module Dual Battery Harness/Long Leads Battery, 12 V, 7.5 Ah Battery, 12 V, 17.2 Ah D8103 D8109 D8108A D8004 D137 D101 D1611162 Universal Enclosure Fire Endosure Attack Resistant Enclosure Transformer Enclosure Module Mounting Bracket Lock and Key for D81 03 Dual Mod. Telephone Phone Cord, 7 ft. (2.1 m) 12 ft. (61 cm) D5200 D5500- ####* D5500- ####*- LTE Hand-held Programmer Remote Account Manager, RAM IV RAM IV Lite * #### represents the version number of the software. Order Processing has the latest revision information. 474878 D9412~7412GSpedficauons Page 5 @ 2001 Radionics D9412G/D7412G Listings and Approvals Fire . UL: Central Station, Local, Auxiliary, Remote Station, and Household Fire Warning. . CSFM: Approved for highrise and non-highrise. Burglary . UL: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household . DaD: Approved for installations in Sensitive Compartmented Information Facilities (SCIF). Access . UL: Access Control Systems. D9412G1D7412G Specifications Page 6 @2001 Radionics 47487B .!!2 '" .9 0 ~ L... <2 ~ .5 c: g 0 ~ U '" .." '" (/)>-. .. IS '" .9 f Q.)~ .~ -;:: -i:: -a. Ii '" Q.) ::l .. u :3 ~ Cf) U ~ <.9~ e f = 8 li: Vl :I: U en o m :z: u en o m . 5l i ;r; '" ~ lJ i ~ lil i fof> 8:.- . ! N "! <Il~z~~~ .ch"~$ ~~!bl 1...; ~ <Il~ :i:; r 11': m ~I ~ :n.3. e- .." .- ~ ...... >- '" !::-g6.g~l:! "'ll:! .. ....01>" :l .2 06~,,-tj ~ ;1,a=""oS,Z " is:l~S~60J! t; ~ ~ :!J \oJ..2 ~ . je~~~]t:.g " ,,~:> &. g jj ~.Il ,g ~ ~t3 = ." a II J "~u 8,g .~ -g 8 ~ ~ 't: ~"'8 ~!: "" 1j .i: .Il~'go""81la l! " <l5 e ~.5 'E 0 .. oS~ !;!"~ii1i ~ Ii ~.~ ~.s ~ 'Ci ~ ii ft = ti: t:: t:: .:::! "iJ a & >-. e-'- .0 .~ ..8 t :::I '0 8'- 0 ~ :l U - 0 - :s ~'2 ~ '15 n ~ " t .!1 t:: :s '" .....R. c:: ~ 1; 1! e = oS :.!! .21'.9 i ~.." ~ =.." g;~..E ,: J:;'~ 8.a a oS 51 Ii b ! Iii u I .F j ~s 1 il ~~1Il j j :t.'i.5 'i I I !il s! II s! .s gg ~H .s ~~ ~U ;:!! 0>0' ~ >> e. ~ .l! o>v ... -'i- ! 0>0> :t~ .... ;q- ~ 1~ .~ ::!~ I~i i~ e I~ i ::!::! IU ~~l 2 gss '" 2 uSs "f 0> ~~ Ii' ~:h 0> Ii' ~gg i g >gg 0 ~~ i5~.I:i '6 -... :;; '6 '" ~~ ~ O!> ~ 0- g~ .>> .Ip ~"'~ 0 ~"l"fgH . Ill! 0 ~ ~ ~ ~ g 11 " l! -eN..... c cr~ I SOo 1l !t cr~ ~ s__ ~~ ~~~ ~ 1""'~> ~ ~ gUO!N;j!j j g."o>N.c ~ ~+ im ~ ~+ >tf.;~<i ~.!~ ;:s g> N ~f:=! jr-- ;:s ......".11 ~OC;:; "!l lo~ ... go Ii sugi " b "!l is~ .~ g~ sugi ~~~ i "'N ; >....~~g~>1 i E ~;~~g~> I ~... ::!... ">~N ~~ ~... ; -:;;g < " + g. o.I~N -~ ;Ii " + ;tlia~::!;j! ~ *"'" "Ii 1II0U~ -12 ~~ f ..~ ~r ." 0 0... ]_\H'" gj1 '" B t~ ]:'~s~ ~ .. :;; :l:w ~ E'j '>s- 0 i! ; NAlr'~o.u ~I 0 l<'! ~:. l~~o.g !!c: I I J => "f · -=> g => "'"I r=>> 'j'+o,e Ii 0. I l","","N :E~ i- 0. h!l~-~~~ till u $_Lg~~~ :f! u => ." jH => "E '" .Il . '" Ii ~ g h ~ nHJU~ 0 nl!JJj~ '" <5 :;; d <5 (/) U1~ u 0 "'.. 0 i& .~ ~ I! ~ . 1 i la ! i i& I t! ~ i ~ - . 0 . .... c U ~ U ~ ss 1 i td ~ i .... ~ ~ B i ~ i ~ i '" ~ 1 ! e ~ I ~u ! ] ... ... Su ... If. 1 " c , u . (/) .. "g E 8 u . . c . (/) " i i j " ! ! ~ 5 Ii I ~ - . . ,51 I ~ ! " ~ '2 i 5 i ! J II E * v;- I (/) 5 ... o '" ~~ :E ] i!!' Jl .0';:: II e-" .:!l 01 .. '0 e :a ~ c ~ !: 'C .;:: ~ 0 c c ?:-~...r '" ~ .S !: .. ~ ~ e 1lll:l .j! .j! l;itae] .iStll~c.?~u"c8"~ 'C g C r4 ~ tU ~ ~ U 1;; ::; ~ 'e 19 ~';;;8 J:: g a-!I)~-S ~; u.~.5 a . ..gell" !l0~-t-"~ '-ll ~~l~1~}~g=~;~!~i 1l - .. "0 e ~ II i= ..c 0 -;,.,,'l! e if 19-E.aa"'.a~ .~~l~~ii"~ ~ ~ 0 J:." "'0 R ',,= 0 ." .5 "'0 '" .~ co] v ~~;~ g~l ='3.5 ~ 5 i G =::1 g ~ n ;s.::q ~ ~ E l!:3 ~ ~ :1~~~a~Jlc~~Ji~a" ~i~1l80~~ill.:!l8"~~' !0Igl~!~~tlg~~81' i~~C~E]o~~~Ce~~w~ ~~..8~..,..e_~~8~~.s~C JD. o L.. ..... C o U ~ "C ::s u Q.) (/) (/') Q.) "C Q.) (/) 19 c ~5~ co '~9 o.!l w"!':!s 80 'C ~,/':l ~ = v 8,.' ." ~ ~ ~ -a.g Il g. t ~ .s ~ ! [; t ti > V) ~ y c ~ t-..= . l5 '~ll]~]ea~o]o'tl~ ': e ~ to -!1 .5 e c:L. i &: OR .5 .8 ~ ... tlS6b~u"'on 4.1.,,"';.:::1 g ~~5C~Y'cS!=ci3~ c o5...!.a....~...o....:s>- 8 a'" ~ )l.5 ~ 0'~'~ ~ ~.~ 1 b 8~e~&..."S.sll"'ilua .~ .~ ~ ~ i':! E .~ ~ ~.g ~ l! g .j! ~ ~~.~.~~~g81le~>"~ s wt-....;::i!!',,&'Eyi:'t~-l;l .. .!l ~ eo- ~<a g :6bli li ~ l!i a i E Jl ..; .c: ~ .g ~ t:a 0 ll:<a ~.j! ::l~01l]g ~ g7J'i~ ~~] ~ I ~J! u ""'80,- ~-g~ u"'g fl C s:: ~a1I-~.s 001...0 l;..lS 8.s (!. i u 1 " ~ ~ g u ID " ID U1 " I U1 f U1 '" o '" ~tHh ~~1 ~iitli fl ~ ~ ~i!! tilDl e Ii i ~! ~i -II (f) .S! .. ~ fl1ij: tt;n "0 tl "e .. !!ti~ . ~ ~:<'. g.~ ! l~pi .b e ~ .1> ~ oS ~ ..!.l "'ll. l~ 111111 c r>. ""] ~'I ~.~ "" ~ ~ !11 S .II (,it ~ :E'~ ~ E e- ..!.l'" .E ~tn 0 " n.g '8 !l;;; = 1 ~:!l ft ".eJ!;~ It lit u ~;;'.., g e-j""l~ 81 ~~UJj~~ ~ .B'IIe. ~ .5~'&.e-.~"1i "'43111 "1.1 loB >)~'"t J II it ~E...g~!~~="i~:I: Iii _*!~i co~u'Uo- ~'-"'1 "~ "'-;5:ot~8~ ~'~::l 1-:;!1111 ~ Ii lilt :J ].~!l~.s :;:~z ~!i5 ...~h~;t~ U "- ~ 11 Ii e 8..~ ~ g ~ g z ~ 0 '5 ~ ... S -I '" ~ I ~ f;; i ; (Qt"lliE Q) ~ ~ ~ y :? ~ :?~ 0 ? ~ ~ N"'pg F (f) Ci.!!:d B Ciu.~JH o lh~ ,S$! 1l ~ G' U ;,~ :::: '01 ~ ~ -l:! .: ... Q) .... ~~ g 8 0 E t3 !! >- .., e- :::: E = g,'" 0 v .- ... :-= 1r 0\ ! 0 ~ u .~ E .Doc iJa-s... ..!! g,1:~e- U . ~ '" '" l188;;; .......] ~" :s~ i ~1l e ~"" I (f) q::= 95gB.. It.'ill ~ g "" )1: :g~ii~ Q) lj e ." ~ .~ I 8 ~ .~ .s ~ ... . ~ i:l g .~ t:! 1: ~ fl'E'~ '" '" e Q) 109 il1l8 I (f) -]g~l ~ ~ ~~ r~ {i l? i ~ .i ~~ 1 .- "'g a ... ~ 5 CI 8I5g.s~ ...::,?",y~~~ CI >- ~ g~ l~ .....2 ~ E .~ ~ v 'g 5 s- o l: o",!!3 ~ ~" ..~ z ';1 '1i ~ ~ ~ u o 0 \"S ~ '8 ;;) ; :; ~ U).....+=~ ~~~~g...R Jlll!< "",,,,- ;e;;;""."_ 8=:::::!E] .gbD~ 8"lt"W'l tit co ate1=::: :E5B~s~ ~ 8 ti l5 E-o ~ C3 ; "0 .- ~"'- ....:ll<'l-5I:="" lli1] ~]~]8!] '5v"t'IS ......J_uEo&: z.rJ5~~~:>ag"~~ il~'2 o~o].g-a.~.t! fl ~(;l iH:?;~::d ~ ~ ~8 ~ ~ = ~ :J .~ B; 8:1l = '" i:l c:a:;~8...._:3u~....~-5a. " .l<l -a-5F: ~gg~g~ 9. iii :1~~~ r>.~gf g.g is..:J ". _:> 11.I u ... 5'- 0 vi ,,~"". o. t::ol:~oo8~1ll = 8.~ .... c ~ .... tlD." ~ ~ ,,~ ~ 0 fj'" 0 - ,_ evo:3~""~i.~M; ~~j>~~1~~e1~ e"'B:se';-E:;o~]~ l.Hjr>.g~l1QE';';;1S. ....~."vco"o-8cII.IO B ~ ; ~ q: C ~." co ~ .:a 'c ::2 ~ ::2 g t ~ M l ~ co !oou-gv._co~c~;€j ~.s e';;~~l ~i~~ Iii II a l1 ~ ;E ~.g . ~ ~ VI '0 .Il :1 fl 5 ~ :a -l:! ] 0 -s j I: ~ 8 'C & ....5.1> ~ li. " C > "'0 ~ ." .5 :::e 0 "'0 c:o:::l 8o;t;l.5;~~;tji '" .s 0 t:: e ~ = 1i: ".- 1-0 " :3 ~a t g'f.e g.';l-o I! [ Vtc"'$--;e ~~ijt:g.g l! " e ll.- = .=t&::."li" .!e~;~ ~ c ~~." ~ 11.I ::) 11.I E" ..:; as 5"'9.'~ '5 ~ .!l! ~ ts I: l'i' i ~.~ ~ u .5 lIle-Mg-l:!~ qI't:: ." ~ '> .~ tj .5 i3 e... e = e iJ!:ES-~g~ ~ ~ ~ .g -i .e:~ o.&t;;.5-l:!Jj& ] t 8:g fl"" ] .~ (;loS .s~ g~ g.& 'i a E ~ .g~ e ~ ._ e " 0 ~ v ~i ~ e o " ..."" ..!.l ::l g~]~-l:!] >-:g :,; ~ ::l ... ~ E'" o =:; :J 11.I U :J m 0 ~ 'g ~ ~.5 ~ ~:a !l ~;]B.g~Jjoe '" .;: "" g 'fl 6 ~ c e- c ~ ;> e u 5 I.i:o t:: ';::::: 0 ';r!":6~!e.~~='€ li::l8o"..I11!=~" ....] n ~:o ~ .~ .tj ~ ~ !Z' t:o ~ 'C '" il i ; -S ... :!~2cX~e"81gg~ I is. ~ (;l ." Go ill ~ ':i '2 .5 o;auPotQ8l':1oo IS. ~ -s .E .l:: r>."" >- = r>. '5 ::. \'J 1a .. '0 'S il "" ~ 1 ~ .5 li! = E '0 0 c Iii 11 ""'~uut:Pu'-" l!O'3~"'t:e~lOl!:a Vt 0 ~ a.. ~ a.. 8 u ~.~ .S (f) c o ".j:i :J "0 (f) "0 C co (f) Q) .~ o (f) (f) Q) U U <( (f) Q) .~ Q) (f) l? .~ 18'~ ~ 4'l ] -a. = ~,; ~ j ~ ~'3 ~ - ~ i.~ i !j j i 1 1.:1 U E "" .5 ~ 15 ...; 5.!C = ~." ~ ~ 'tj ~ ~ " :E l-i..,g~~ E] c!,g t ~~ "'..r:! ~.~ 1~~-5~'~Lgg "" e ,g,~ e,5 ~1 t!.st!~~1~1 . . . . ~ ~'ii] li .~ 5 """ '8 .0 ~ e 1 ~ "'~-S1l~-S-s'::o8 :!.o -S.. ... 5 e.8.'" tl ell_"' 'i5.5!:~'S."5:;11l H :a Ii Y. 'i , 'ij'~ = 0 El ~~ llvlil~'''e'6~l:l ~ ;:::JtlS:.E:; .sa.c!! ,,~':iF=lIi.>-u8o II ~~O' ee",,~>- e..g..cB.s;a-a. .0 ~ E.~ t;;..].2 e ~] l! : * <3 $ l'f~"ij 6 ~ ,i ':! i'E!!l~'i g{~~ S~i ~J~~j~!tg~t '51~i "]~;",;"'1l5""'e ~1 e' ""C 'C is.'r>. l! l'f II ": " "" e ;l = r>. It'I>'' . ! ~e,:,;~~8~'l.!S ~5 '" ." i u - o u . Vl .. e ~ is u . . Vl " ! Vl f Vl '" o w ~ ]", !l .g "di ;l:.a c "tJ .~ g] ~~ .5 ~." .. 3 B ~ ~ ~ ~~ c ~'il ~ e; ::; .S! El Cl. S a 0 g~;lliS'~ r~ ~~ ~.~ ~1!l1"~~~ .5 ~ Q Ei -" 0 8.'~~t]""~ !~J;!8.i.s ",00><:1'" .~ 'E e; oJ - 'E ;a !! 11) ... ~ 0 .s ~ is ~.&.5 00 ~ - "~.~ . ...s~"''''~ 'E 8 ] ~ ~.g ~ ~ u g E .5 .~.. VI c: u v C ~ ""0 of: l:t ~ oS .g 1ll II !t -i;l'i3"c a]~-5goS: ;cbea.~~B of:! '2 ~ g ",.5 - r" s -.<: c '" 0 . ~._Cl..u~;5 e; g '! '" 00 ." . -5 e; l:;'E'~ 2~ jp~8~J!~l;; VI to to a ~O: .5 1l~"8 ;l 0.5 . e; 8"l:;~'~.a-il" .t~ellIli~~~ l1 _ 6 '" g ~ .. ~ ~ ~ ~'R 'g t:.~.D"~ to] ~g e8!"3o(;c~~ ...g....~~ 0 ~ ~ ~~ .a ::ot:....ao..c .~ oco.50"'),! ::ao~.g~&~~a. c..i\1Gw5'wS.." .- '"' -a v '"' u E! "'0 ~la'~~~i>. '5!t" .~ g] c ~o e! 'S 0 ~ . .. " "0 '" c ! '" ~ e:sl e; '" ~"c 13 0 ~ .~ ~ u ~ ": i a.9 u .~ ~ 5-1':e'0 ~~ e~ 2,9 i.g l~ ~~ ~] ~ g \a ~ ~ l1" = .Ef'~ ~ ,,'g !t 11 'i!" Ii 8.'3 t:g;;;'2.8 J! 8i!~i![.g~g~~g .g] c e ~ .~ ~ ~ .g a c ,,'fi'e; II .il e tl ~ .- ~ 1Il '" c - il g.5 :" ~ .9 <E ~'c E! e ; e 5~tOfjS..g2'S "'"-8$.,,ooow 'S 5 .~ ~ go ~ ;ij ~ . >'8.l5..",.lIl"c,,~ E 0;t:~e'3E "8~; ';:Saj "'J;! if'" !.!!~~-8.iE~~-] o..g:.a ~ ~.t::"; II) C U e; .5 -0 c .5] E ::> E e; ; J;! 8..1Il c ~ :'"s <<I ~ tJ ~ ~ ESe .5 '0 c e's :: e; ~ ~ gee .=:<Cl.tl...J!cc...e", ..... 0.. 0 to co :::s 0 ~ 0.. 'E If 13 l:! !l~ ... Cl. o Cl. " '" 00- c 0 ~ 5e ~ .5c i3 1 .S- ~.g c '[ ~ i -: ] -'~ ~ o 0 ~ e 0 ~'E 0 .~ ~ ~ ~ -E oS.~ g U) g 'g ~.~ e~ a~g ~.~~.~ ~uia~ ~1~ ~~1 ~1~1=]~~~8 !i ClJ.... bb c ~ 0 toO co ClJ ~ ClJ ~ CI) ;.:: t; ~"8 ~ ,g ~.g )1 :l E ~.s 8 ~ i3 'j) ij !! E 8wv~eo~wvoee'cve~o~ ~81]~~7~~~7~~~~~~~ ~ ~~ 'E ~ ~ g .2P-g ~ ..:illg.~:'" !l'E! C.;; ~ ~-e :s 0 '" .- ~ ~ .. ~-g~~eo.~ ~ co co ~ 5 d :: ~~~f'$~;~ o'il'e~-i..c~ . l:>o~1:~~ou 8 -i ~ v - .5 ~ a .!D ~ ~.fj e'E ~ :; 8 ; i:g 0 &.8 ~.~ K. .:I..!:! :: "0 :i W'~ ~ l> J! .1Il ~! E Ii 'e ." ~w'~o:""~=~ =]<l\iS..~Jl'oJ! tl ~ Jo:" 5 .5 'i3 S '0 is tl ib~ ..a E ~ 9 ~ ~~ rl oS sl ;;: S ~ ~ etC~e~B ~il<;5e.~~ !l ~ g. il ..:: 'g "i! :3 e e.s ~ e .~ '" ~ ~'+:j c G ~ 0 " N _ -" _ ".~.;; "'S Cl.<J . - E " .t'''"':~B~'''; J!'S"8~E-~il", co ~..c..c _ .. $ J;! ... 'C tl " " 50 is.. a ~ Jo: e:sl !1- e .5 'S 'l"e~E~"'- : 1! ~ g.1I g] ~ i-o lI':I >.:.a u :s ~ " ~ it 1< ~ cb ~ ~ ~~ .~ ::> ~~ ~f3~ ~ 2- ~e g-E.~ ~ :r:] u 6~ .g tJ .g N '" ~ eN] .!Dse: ~0i ;~l:t~~ :e~ 8ce cc~~Cie:I: ~~ 9 c 0 e .g.2 f!>li: ~ ~ j! Q.~ ca .g'c u::: co i! :s ~ 0 -1 CC3 a~3 r.i5<.1')l:Qa)-t~:= ~ ~'<J '" -'<J ~ - ;g '" ~ 0 ~ co'E b] 8 g b] 0 S.8.!! z-~ IlLEe; ",ce 5ClllE...~u l!'~ e; ~ a e <>: a 5 ~ 0 i1i ~ 3 ~ y . . . y . . . ~ ~ ~6~ yj' u g -g ;; 'g.1! c ~ 0 .... 13.5 !l g yj' 0 0 "0 e"tJ '" ~ -i-g~e. ~~5~ :g'~ 5 1l "tJ !t e .!! ~.5 ':"8] o II '" 1: e; 11 Ii '! 0'- " J:~~~~S! i ~ ~.;; \!.~ ",_~.5c_ os:g~fJS ~:3"g~t~ "e-.. ... !l ~ ~ ~ "'0....2 8~~illll.f,g ~~e-]~~g i:;-~~.):~.g9 il Cl. if ~ ll.~ g. ~.~o~ ",eQ.';; :8",E<SSg..): l!.lil e'" "'.!!...... ,...c,,~-8.Q8i1 u e oS '" '): :"I!Ei filo ..~:l~<~'i3" ICI):=.s~~s.g .; c '5 0 .8 '" e ~ . ,",.2..w~t cb x:1G;:e\l~=.s.s'"ij ill:.1! ;l c ill'S .5 ." '5 g; <.!! 8 ~ ... ~ e-5 l ~ g 9 'i ~ ~ ~ ~ w "0] C !f>; 'i3 ':9~J';;; gg.13 .~1l .... ~ >.. ~ co ~-EfJ'!f>~l ." e ~." " .. =~"'t:;S::: 'C e- 0 f'$ 2 ~ ~ Cl.'!: l1 - Cl. .... ~ .~ s: &! " \!.g c tl ,,::> C =.~ .0 E';; i ~ II 'i3 g...!! Iq li ~ .5 uftlg...3u~ of:!'g..cl;cb.E! l:! 1: '" u... 5';; 0 gll ~.~]-'i'~-g ~ ".~ '" c II c '" . 0 <J'C..,!!", > ~ j:l.. ftI 1:..0 UOJZ.S 1871 - Control Units, System Page 1 of riQI Online Certifications Directory UOJZ.S1871 Control Units, System !)age Bott~~ Questions? Control Units, System Guide Information BOSCH SECURITY SYSTEMS INC SUITE 106 20 RAGSDALE DR MONTEREY, CA 93940 USA S1871 I Type Type Type Service Signaling Model CSi(RU), RS(RU)++ A, M, WF, SS C, DAC D6500# CS(RU), A, M, WF, SS DAC D6600# L A, M, WF, SS - D9124 CS(pPU), RS (PPU) A, M, WF, SS DAC D9124# A A,M,WF DAC D9124# CS(pPU), RS A, M, WF, SS DAC D2071A, D2071AC L, A, CS(PPU), RS(PPU) A, M, WF, SS NC, DAC D9024 DlO024, DI0024D L A,M,WF,SS C,NC D7024 CS (PPU) A,M,WF,SS DAC D7024 RS (PPU) A,M,WF ,SS Dac, Rev. Pol D7024 A A,M,WF NC D7024 CS (PPU) A, M, WF, SS DAC D 1 0024, D 1 0024D L, CS(PPU), RS(PPU) A, M, WF, SS NC, DAC D8024 CS(RU) A,M,WF,SS RF SC-9000#,SC-9001# http://database.u1.comlcgi-binlXYV/template/LISEXT/IFRAME/showpage.html?name=UOJZ.S 1871 &ccnsh<.. 2/6/0 UOJZ.S1871 - Control Units, System Page 2 of CS(PPU) WF,SS RF SC4000, SC-4000F# C L, CS(PPU), RS, A A, M, WF, SS DAC D7412G, D9112B1, D9412G L, CS(PPU), RS(PPU) A, M, WF, SS NC, DAC 7022# Rev. Pol. ++ _ Remo1ce station series only when used with UOJZ Listed Radionics VIP Series automation systems. # _ Must bt:: used with specific devices as indicated in installation instructions and wiring diagrams to provide indicated servIce. Subassemblies and enclosures for use with Radionics products where referenced in the control unit installation instructions: D4103, D4103R, D8103, D8109, D8109G, D8109H, D8109L, enclosure; D8108A, orD8108AH, enclosure part control stations; D125B powered loop interface; D127 reversing relay assembly; D129 dual Class A interface; D132B reversing relay module, ~ dual phone line switcher; D192C, D192D, D192G bell circuit supervision modules; D-I05-FL end ofline resistor assemblies; D8129 octo-relay, D8130 release module; D8122 derived channel S.T.U., D8132 booster power supply; D8131, D9131, D9131A printer/CRT interfaces. Zonex subsystem, consisting ofD8125 Zone expansion module; D9127T, D9127U POPIT modules; D8128A, D8128 Eight zone: point modules. 1 1~ls D268, D269, D279 Independent zone controls. Models D 130, D7025 Relay modules. Model D184 Master box tie-in. Model D7039 Mux expansion module. Model D7042 Eight input module. Model D7034 4- Zone Expander. Model D7035 Expanded Relay. Model D7014 Class A Adapter. Model D7039 MUX Expander. Model D7042 Eight Input Remote Module. Page TOI~ Notice of Disclaimer Questions? UL Recognized Components Products Certified for -,-..~~----- Canada UL ...Asted and Classified Products http://dat:abase.u1.com/cgi-binlXYV/template/LISEXT/1FRAME/showpage.html?name=UOJZ.S 1871 &ccnshc. 2/6/0 UOJZ.S1871 - Control Units, System Page 3 of This page and all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ Tl- llpearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured 1.: UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up ..Jervice. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright @ 2004 Underwriters Laboratories Inc.@" http://daltabase.u1.comlcgi-bin/XYV/template/LISEXT/IFRAME/showpage.html?name=UOJZ.S 1871 &ccnsh(.. 2/6/0 01256/01257 Fire Command Center/Fire Annunciator Specifications Features . Compatible with the D9124, D9112, D9412, D7212 and D7412 . Attractive low profile fire annunciators . D1256 provides system control with easy to use function keys . D1257 can be remotely installed in public access areas . Built-in multi-tone sounder . Easy to read vacuum fluorescent display . Displays complete system status in English format . Programmable custom text for each point · Local system test display . Molded red ABS plastic construction Description Radionics' D1256 Fire Command Center and D1257 Fire Alarm Annunciator are four-wire serial devices used with the Radionics' D9124 Addressable 24 VDC Fire Alarm Control/ Communicator and the D9112, D9412, D7212 and D7412 ControVCommunicators. One D1256 is included with the D9124 panel, which can be accessed through the slide door on the front of the enclosure. Both annunciators provide English text displays of system events with highly visible blue vacuum fluorescent displays. A built-in sounder alerts building personnel to system alarms and troubles and guides responding agencies to the annunciator location. Both units are molded in durable red plastic and have low profile enclosures. The wording "Fire Alarm Annunciator" is clearly printed on the faceplate of the D1257. This allows inspectors, service technicians and responding fire agencies to identify the annunciator. The D1256 Fire Command Center is a full-function system controller and annunciator. Four special one-touch function keys provide user-friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display and reset system detectors. Four additional navigational keys allow access to other programmed system functions. The D1257 Fire Alarm Annunciator provides remote annunciation capabilities without system control. Similar in appearance to a D1256 Fire Command Center, yet the D1257 Fire Alarm Annunciator lacks function keys. This makes system control functions inaccessible to unauthorized persons. Thus, the D1257 can be placed in locations where the publiC may have access to it. Two navigational keys allow the user to step forward or backward through a list of system events. Fire Command Center and Fire Annunciator Application The D1256 can be mounted in secure areas for use as both a system controller and annunciator. The D1257 Remote Fire Annunciator is typically installed in building entrances and areas with unrestricted access. Near exterior doors in hotel or business lobbies are ideal locations. This allows a responding agency, or persons evacuating the building to quickly identify the type and location of the emergency from outside the building without being in danger. Both devices have a built-in sounder that allows them to be installed in locations not in general view. Audible tones alert personnel to fire system events and assist fire fighters in locating the annunciator. Installation The D1256 and D1257 system annunciators connect to the fire control/communicator through standard four-wire cable. Shielded cable may sometimes be required where excessive EMI is a problem. The field wiring connects to a four-wire harness supplied with the unit. This hamess plugs into a four-pin connector on the circuit board through the back of the D1256 or D1257. Each unit has three mounting holes in the base that allow secure, correct positioning during installation. Do not install the D1256 or D1257 in direct sunlight. This damages the module components and makes the display less visible. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. ~ Radonics. Operational Data The D1256 and D1257 operate through the Serial Device Interface buss of the controVcommunicators. The D1256 and D1257 receive serial data and power through a four-wire cable. Both devices continually show the status of the fire alarm system. Changes in the normal panel condition such as alarm or trouble events are displayed in alphanumeric English text and the appropriate sounder response tone emitted. Resetting the display and sounder can only be accomplished at the D1256 Fire Command Center by authorized persons. Specifications ,H :C'~' '~-- "I ~ ,-' , " f --.''''1''',,, ~l-~.'.' ~l!).f,:;~;'cl'-:;\ " -,;. . ~l.;~ > 4 '_.....:;; _, " __ _ ~' , .. ~: ~~ ~;~:~:: :,~~~ :~i:fJ$~~ Operating Vo.age Nominal 12 VDC (supplied by controVcommunicator) Operating Current 104 mA min.; 206 mA max. Wiring Four conductors supply: Serial data. +12 VDC and panel common Display 16-Character vacuum fluorescent Operating Temperature +32OF to 122"F (OOC to +5O"C) Non-condensing Relative Humidhy 5% to 85% at 860F (3QoC) Base Dimensions (L x W x D) 8.3 in. x 4.5 in. 0.8 in. (21 em x 11.4 em x 2 em) Wire Information ":'ll'"4-''''":''~~'m!i''''il'1''''J,,",j'~',~''_~ ~~~ "~: h ~~ ~~'~~='_~_'~_H':~'~~~>~_lCi~I<~f1i~ 12 VDC 12 VDC (Red) Data-Out Data-In (Yelow) Data-In Data-Out (Green) Common Common (Black) Listings and Approvals · UL Listed · CSFM Listed · FM Approved Ordering Information 01256 Fire Command Center 01257 Remote FIR! AIann Annunciator D54B Brass Faceplate D54C Stainless Steel Faceplate D55 Desk Stand D56 Conduh Backbox Specifications The contractor shall furnish and install, where indicated on the plans, Radionics D1256 Fire Command Center and D1257 Remote Fire Alarm Annunciator. Each device shall have a 16 character vacuum fluorescent display and show all fire system events. Alarms shall be prioritized ahead of other system events and displayed in sequence. The D1257 shall have no on board system control function keys. A built-in sounder shall indicate events with distinct tones for fire alarm and system trouble. The D1256 and D1257 shall connect to the fire controVcommunicator through a four-wire cable. The D1256 and 1257 shall be constructed of high impact red plastic. The D1257 shall have the text "Fire Alarm Annunciator" clearly printed in bold letters to the right of the event display. The D9124, with the D9112LTB, D9112B1 and D7212B1, have a 500 event non-volatile event memory log. The D9124 with the D9112L TB-EX or D9412GL TB, 9000/7000 Series panels have a 1000 event non-volatile memory log. All system events are displayed on system annunciators, printed locally or retrieved from oft premises via the Remote Account Manager (RAM) software package. .o~o CERllFICATE NO. A5137 @ 2001 Radionics, a division of Detection Systems, Inc. @ The Radionics logo is a registered trademark of Radionics, PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 75-06926-000-B Specifications L643 01/01 D1256/D1257 Page 2 of 2 08132 Battery Charger Module Specifications Features . Provides additional standby Amp hours for control/communicators . 1200mA battery recharging circuit . Suitable for 12 VDC, 7 and 18 Amp-hour batteries . Suitable as a stand alone 12 VDC, 1 Amp power supply Description The D8132 Battery Charger Module is an accessory device for Radionics D6112, D7112, D8112, D8124, and 9000 Series control/communicator panels. The D8132 uses a 16.5 VAC, 40 VA plug-in transformer to supply 1200mA of battery charging current. An on-board, green LED remains lit to indicate the presence of AC voltage. The D8132 can be used to increase the standby battery time of a panel when instaUed with external batteries in an adjacent approved enclosure. The D8132 is not to be used as the sole means of standby power for a panel. One or two 12 VDC, 7 Amp-hour batteries must still be provided for the panel. The D8132 can also be used as a stand-alone power supply in non-UL applications. You can connect one or two 12 VDC, 7 Amp-hour batteries or one or two 12 VDC, 18 Amp-hour batteries to the D8132 in either application. In addition to providing increased standby time and auxiliary power, batteries connected to the D8132 also filter the AC power supply. The amount of ripple that appears on the panel outputs is dependent on .the charge state of the batteries. Radionics does not recommend using the D8132 to power devices that are sensitive to excessive ripple. Application The 08132 Battery Charger Module is suitable for systems requiring extended battery standby time. The D8132 is UL listed for use in Central Station. Household and Local Fire and Burglary Alarm applications, Police Connected, Remote Station, and Electrically Actuated Transmitter applications. The D8132 is not UL listed for use with the D6112. Provided with the D8132 are two cables, and two sets of lockwashers, nuts, screws, and terminal lugs. The cables connect the D8132 to the D1640 transformer, one or two batteries, and the control/communicator. Additional hardware is provided for connecting the battery cable to 12 VDC 18 Amp-hour batteries. This $ radlonics hardware is not required when connecting 12 VDC, 7 Amp-hour batteries. Installation The D8132 Battery Charger Module and additional batteries are typically mounted inside a separate approved enclosure such as the Radionics D8103, D8108A, or D8109. The enclosure is instaUed adjacent to the control/communicator enclosure. The plug-in AC transformer is installed on the same AC branch circuit as the control/communicator transformer. No other devices may be connected to the transformer. A 4-wire harness is used to connect one or two batteries to the 08132. An additional 4-wire hamess connects to the AC transformer (2 wires) and the battery terminals of the control/communicator. The D8132 installs in the enclosure using three plated screws supplied with the unit Radionics enclosures provide module mounting locations with knockouts. Use a Radionics D137 Mounting Bracket when installing the D8132 in a non-Radionics enclosure. The D8132 should be mounted towards the top of the enclosure away from the batteries to avoid overheating. The Radionics 08103, D8108A, and D8109 enclosures provide a rectangular knockout on the door that allows the green AC power LED on the D8132 to be easily viewed. A memller of the Bosch Group Operational Data When using the D8132 to increase your controVcommunicator panel standby battery Amp hours, refer to the appropriate calculation chart contained in the 08132 Operation and InstaDation Manual (74- 04777-000). These charts detail the Amp-hour requirements, controVcommunicator AuxUiary current load, and the D8132 battery recharge time. The D8132 can also be used as a stand-alone, 12 VDC 1 Amp power supply. For stand-alone applications the D8132 does not provide battery supervision or load shed capability and is not recommended for critical loads. The D8132 is not UL listed for stand-alone applications. A form of battery supervision can be provided to a D8132 in stand-alone configurations when connected to the same AC branch circuit as the panel. AC power l'ailures and restorals, which would also affect the 1)8132 module, can be reported by the panel to a remote receiver. This supervision relies on the ;:issumption that AC power to both devices has been affected. The Amp-hour rating of batteries on the 108132 should be greater than batteries connected to the panel. This ensures that devices connected to the 108132 are powered at least as long as those on the control/communicator. The stand-alone D8132 and the panel must share a common ground. Specifications Operating Voltage 16-18 VAC supplied by plug- in transformer Operating Current 1200mA of rectified AC Float Voltage 13.9 VDC maximum current Dimensions 5 in. x 3 in. x .8 in. (H x W x D) (12.7 cm. x 7.6 cm. x 2 cm.) The contractor shall furnish and install Radionics model D8132 Battery Charger Module where indicated on the plans. The D8132 shall provide increased standby Amp-hours for the specified Radionics control/communicator panel. The module shall be equipped with a 16.5 VAC, 40 VA plug-in transformer, two sets of connecting cables and all hardware required for proper installation. The D8132 shall have an on- board, green LED for indicating the presence of AC power. @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012, USA (800) 538-5807 The D8132 shall be capable of supplying recharging current for one or two 12 VDC, 7 Amp-hour or 18 Amp- hour batteries. The module shall be mounted in the recommended Radionics enclosure or other approved enclosure. Installation shall be subject to the requirements of the authority having jurisdiction. Listings and Approvals . Underwriters Laboratories . CSFM . BSA Ordering Information D126 D137 D1218 D8132 12 VOC 7.0 Amp-hour Battery Mounting Bracket 12 VOC 18 Amp-hour Battery Battery Charger Module 1S09002 0 CERTIFICATE NO. A5137 75-06430-000-C 8/01 Specmcations D8132 L515 Page 2 of2 08130 Release Module Specifications Features . Two Form C, 5 Amp rated contacts . Supervised disable switch for system testing . Easy to install . Remote control of fire system devices . Instant or delayed relay activation and restoral . Compatible with D8112, 08112E & G Series, 09112, D9112B1, D7212, D7212B1, D7412, and D9412 control/ communicators . Relay closure follows indicating circuit duration Description The D8130 Release Module is an accessory for Radionics Rre Alarm Control/Communicators. The 08130 is suitable for release applications commonly found in NFPA 72 Local Fire Alarm Installations. Two independent Form C dry contacts, each rated at 5 Amps, connect low voltage circuits to magnetic door holders, pilot relays, or contractor units, for release function control. Contact activation on alarm is jumper selectable to be either instant or delayed by ten seconds. If the delay option is selected, a ten second delay also occurs upon restoral. The control/communicator indicating output activates the contacts of the D8130. A red" ALARM INPUT' LEO is provided on the 08130 module to indicate contact activation. The duration of the contact activation follows the programmed indicating circuit time. If the user silences the alarm output, the 08130 contacts are deactivated. Latching features must be provided for pilot relays or contractor units requiring release control beyond the programmed indicating device time or after manual silencing of the indicating circuits. Disable Switch To facilitate fire alarm installation testing, the 08130 Module contains a supervised disable switch that prevents release operation. An amber "OISABLE" LEO is provided on the D8130 to indicate when the switch is in the OISABLE position. The D8130 is connected to any unused protective zone or point of the control/communicator to supervise module disabling. A trouble is indicated on the controVcommunicator when the 08130 switch is in the DISABLE position, and a restoral is sent when the switch is retumed to the NORMAL position. When the contacts are activated with the switch in the NORMAL position, no trouble indications are sent to the control/communicator. D8130 Release Module Release Contact Outputs A normally open (NO) terminal, a normally closed (NC) terminal, and a common (COM) terminal are provided for each 08130 release contact. Silk screened markings on the edge of the circuit board clearly identify each terminal. In the inactive state of the contact, the NC terminal has continuity with the COM terminal. In the active state of the contact, the NO terminal has continuity with the COM terminal. Application The D8130 Release Module is used as a control/ communicator accessory to provide system control functions commonly required in NFP A 72 fire alarm installations. Typical applications are releasing fire doors, emergency exit doors, stairwell doors, elevator recall, smoke exhaust functions, and HV AC control. Installation The 08130 Release Module mounts in the control/ communicator enclosure or in a separate approved enclosure. Up to four modules can be installed using the mounting locations provided. A D138 Mounting Bracket is required to mount the D8130 in the D9124. Install, test and maintain this device according to the Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. Wiring to Control/Communicator Four wires from the D8130 module common (1 COM), altemate alarm output(2 ALT ALRM), +12 VDC (3 AUX PWR), and protective point (4 SWITCH SUPERVISION POINT) terminals connect to the controVcommunicator. These wires connect to the terminal block on the D8130. ~ Radonics. Specifications Operating Voltage Operating Current Wiring Relay Rating Nominal 12 VOC supplied by the control/communicator 16 to 22 AWG between 08130 and control/communicator idle: 7 mA Contacts disabled: 17 mA Alarm: 60 mA Use standard voltage drop calculations to determine correcl contact wire size Dry form C contacts: 5.0 Amp rating at 30 VDC 5.0 Amp rating at 40 VAC Dimensions 5 in. x 3 in. x .75 in. (12.7 cm x 7.6 em x1.9 em) (HxWxD) ControVCommunicator Inputs 11,13,14,16.17,19,20,or22 (connect to positive side ot supervision loop) Listings and Approvals · UL listed . NYC-MEA approved . CSFM listing: approved Ordering Information 08130 0137 0138 Release Control Connections @ o O 12.15,18,or21 ~ (connect to panel common) Radionies model D105F end-ot-line resistor required if no D192C module attached Additional 08130 Modules ---~ ---(i) @- ControV Communicator Earth Ground Release Module Accessory Mounting Bracket Accesso D192C Module ~~~Msion @COM D8130 Wiring Connections ISO lIOO2 0 CER11F1CATE NQ A51:fT e 2001 Radionics, a division of Detection Systems, Inc. <Ii) The Radionics logo is a registered trademark of Radionics, PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 PIN: 75-06348-000-C Specification Sheet 03/01 D8130 Page 2 of 2 08129 Octo-Relay Module Specifications Features . Programmable relay functions . Provides 8 Form C relays 1 Amp at 12 VDC relay contact rating . Operates with the D8112 (serial bus) and 9000 series (zonex bus) communicator panels . Slide switch configuration . Allows remote control of relays . Screw terminal connections Description The D8129 Octo-Relay Module is an accessory for Radionics Fire or Security Alarm ControVCommunicator panels. The D8129 provides eight programmable Form C relays. Each relay provides dry contact switching rated for 1.0 Amp at 12 VDC. The relays are accessed through on board screw terminal connections. The Octo-Relay Module uses information from the controll communicator serial data output to activate the relays. On- board switches are used to configure the Octo-Relay Module for different operating modes, or to specify relay output numbers. These switches, along with panel programming options, determine the D8129's response to the serial data. Programming within the panel can activate specific relays or set of relays in response to system conditions. For the 9000 Series (D9412, D9112, D9112B1, D7212, D7212B1, D8112, D8112E Series, D8112G Series, and D7412, slide switches are configured for specific relay output numbers, which are activated according to their programming. The D8129 Octo-Relay Module uses five slide switches with multiple setting options to configure its mode of operation. The D8129 receives serial data from the control! communicator and activates relays in response to panel conditions and slide switch settings. Relays can be programmed for remote control from a panel command center. Each relay has continuity between the common terminal and the normally closed terminal while in the inactive state and between the common terminal and the normally open terminal in the active state. 08129 Octo-Relay Module Application The D8129 is suitable for applications requiring Form C relay to operate auxiliary systems or to display fire system status at remote annunciators. Building components such as HVAC, door lock releases, and stairwell pressurization can be interfaced with the D8129 for complete system control and monitoring. Industrial, commercial, and institutional facilities are typical installations for the D8129 module. The eight on board relays can be programmed to activate on system alarm, system trouble, individual zone or point faults, and through remote control by authorized users. Installation Up to four D8129 Octo-Relay Modules can be mounted in a Radionics control/communicator enclosure. For additional modules, or for mounting the D8129 in non Radionics enclosures, use the D137 Mounting Bracket. The D8129 connects to a panel using the 12 VDC Auxiliary output, Serial Data Output, and common terminals. Radionics recommends a minimum of 22 AWG (0.8 mm) wire for all connections. The D8129 Operation and Installation Manual (74-04562-000) provides detailed installation and module configuration instructions. Install, test and maintain this device according to the Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. $ radionics A mem:Jer of the 30sch Group Specifications 'llll,il!,:ll'!:~~ ~~:' Operating Volta e Operating Current Wiring 12 VDC supplied by the control communicator Min. 20 mA Max. 220 mA all rela ener ized 16 to 22 AWG (1.5 to 0.8 mm.) from controVcommunicator to D8129 Form C dry contact (1.0 Amp at 12 VDC). During pulsed output, relay maintains closure for about 1 second 5 in. x 3 in. x .8 in. 12.7 cm. x 7.6 cm. x 2 cm. 08129 Typical Form C Relay (8 Sets) tI%I ~ Slide B Switch B '19 .,. <:: )( } To Control/Communicator Listings and Approvals . Underwriters Laboratories . MEA . CSFM Ordering Information D8129 D137 D138 08112, 08112G & E Series } 09112,09412, 07412,07212, 09112B1,0721261 08129 D8129 Wiring Connections ISO SOO2 0 CEqTfRCATE NO. A5137 @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 75-06347 -OOO-D Specifications L1135 8/01 D8129 Page 2 of 2 ~ Radionics'. Features . Provides point identification of initiating devices . Supervises wiring to devices for circuit integrity . Compatible with 07212, 07412, 08112, 09112, 09412,and 09124 ControVCommunicators . Expands the number of points of protection in the system · Compact size . Terminal connections for reliability · Multiplex technology · Low installation costs Description Thl~ 08125 and 09127UfT expansion modules are a proven multiplex technology combining zone/point supervision with individual device addressing on one pair of wires. The controVcommunicators use the 08125 to provide for expansion beyond the standard number of zones up to a total of 240 points of protection. Each 08125 module can fully supervise 120 09127UfT (Untampered andTampered) POPITs(Pointof Protection Input Transponders). The 09127 is a compact, addressable device. Future system expansion is very economical as they can be splliced in anywhere along the two wire data expansion loop from the 08125 module. Four screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Application The 08125 and 09127UfT Modules are used when there is a need to expand the appropriate controVcommunicators beyond their standard number of on-board initiating zones or points. Listings and Approvals · UL listed · NYC-MEA approved · CSFM listing no. for 08125 and 09127: '7167-801 : 104 (household) 7165-801 :102 (non-high rise) 08125 and 09127 Addressable Expansion Modules Specification Sheet I t:~ ~ ~ Installation The 07212 and 07412 controVcommunicator uses one 08125 expansion module to provide a maximum of 40 additional points of protection. Up to two model 08125 expansion modules can be used with the 08112, 08124, 09112, 09412, and 09124 control/communicators. The 09124 Control/ Communicator basic system comes with an integral 08125 module and can accept one additional module. Each 08125 installs in the control panel enclosure or in an adjacent approved enclosure. You can supervise up to 120 09127 POPITs with each 08125 module. The 09127UfT POPIT modules are suitable for applications where specifications call for point identification from each initiating device or series of devices. The units are small, and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. CONTROL COMMUNICATOR ZONE EXPANSION LOOP ! D9127UIT POPIT MODULE TO OTH POPIT MODULE 08125 ZONEX MODULE 33 k END-OF-L1NE RESISTOR POPIT SENSOR ~P (MONITORS NORMALLY OPEN AND/OR NORMALLY CLOSED DETECTION DEVICES) 75-07506-000-B 3196 @ 1995-1996 Radionics Ordering Information Model Description 08125 07212,08112,09112,09412, 09124 Expansion Module 09127Urr Point of Protection Transponder Electrical Specifications Operating Nominal12 VOC supplied by Voltaae controVcommunicator Operating 50 mA per 08125 module plus Current 0.5 mA per 09127Urr module Operational Data Each 08125 expansion module monitors the 09127 POP ITs over a two-conductor supervised data expansion loop. Off- normal sensor loops (open or shorted), missing, and extra POP ITs are quickly identified by device address and the information relayed to the controVcommunicator. Each 09127 provides one supervised point of protection. Normally open and/or normally closed contacts may be connected on the same sensor loop. A 33k.Q EOl resistor is provided to be installed at the furthest point on the loop for proper supervision. wiring Information (i) ....II1_LOOP <<l._o~- G> . ...111.-n:H ILOCK 1UIIIINAL COIIIlECTOIl8 . AUX POWEll - __A" ANALD_our -~I e e _il_~l'l mmmm-=- =:--- Specifications The contractor shall furnish and install the 09127 POPIT expansion modules as indicated on the plans. Each POPIT shall provide a supervised sensor loop for initiating devices and identify the device status in off-nonnal conditions. Each POPlT shall be assigned a device address as indicated on the plans and annunciate at the specified locations. The POP ITs shall connect to a 2-wire data expansion loop from a 08125 installed in the controV communicator enclosure. The 08125 module shall be used for 09124, 09112, 09412 or 08112 controVcommunicators and provide supervision for up to 63 or 120 09127 POP ITs on each of up to two modules. The 08125 module shall be used for 07212 controV communicators and provide supervision for up to 40 09127 POP ITs. Specified Radionics control/communicators shall be capable of providing device point identification to a remote Radionics 06500 receiver using the Modem II reporting format. All wiring shall be in accordance with the manufacturer's instructions and follow all applicable codes. Dimensions 08125/08125X: 5" l x 3" W X 3/4" 0 09127urr: 3 3/16" l x 1 1/2" W x 7/8" 0 a> a> ™ The Radionics logo is a registered trademark of Radionics, Salinas, CA, U.S.A. @ 1995.1996 Radionics, Salinas, CA, U.S.A. All rights reserved. Radionics, 1800 Abbott Street, Salinas, CA, 93901 U.S.A. ~ Radionics.' Notification Appliance Circuit Supervision Module Specifications D192C Features . Supervises 12 or 24 V DC Notification Appliance Circuits . Supervised signal silencing switch . Notification appliance circuit rated at 1.8 Amps . Multiple module configurations . Mounts in panel enclosure Description The D192C Circuit Supervision Module is an accessory module for use with Radionics Fire Alarm Control Panels (FACPs) and Controll Communicators. The D192C supervises the wiring to remote Notification Appliances in compliance with UL 864 and NFPA 72. The D192C powers Notification Appliances either from an FACP or from an auxiliary power supply, which allows the use of 12 or 24 V DC Notification Appliances with the appropriate power supply. The D192C supervises the wiring to Notification Appliances for open circuit, short circuit, or grounded circuit faults. It responds to these conditions by causing a shorted trouble condition on the FACP supervisory zone or point. The panel then provides audible and visual waming at the command center(s). Panel programming may provide Notification Appliance supervision reports to a remote receiver. In an alarm condition the panel output voltage triggers the D192C to supply power to the Notification Appliances. The D192C module also filters and stabilizes the output voltage to the Notification Appliances in the event the battery power is interrupted. Several D192C modules can be connected to the same supervisory zone or point of the FACP or control/communicator. The D192C module has a silence switch to disconnect power to the Notification Appliances during system testing. When this toggle switch is in the Silence (OFF) position, the D192C shorts the supervisory zone or point of the panel, causing a trouble condition. Notification Appliances used with the D192C module must comply with the following: . Must be polarized (DC) equipment . Must match the voltage rating of the alarm power supply . Must not exceed the current rating of the alarm power supply . Combined device current must not exceed 1.8 Amps per D192C module Application The D192C Module provides a supervised connection point between a Notification Appliance circuit and the FACP. It supervises the Notification Appliance circuit for open, short, and ground condition, any of which the F ACP will report as a trouble condition. In an alarm situation, the FACP signals the D192C to power the Notification Appliance circuit, either from the F ACP battery or from an auxiliary power supply. I.. mem:Jer of the 30sch Gr~u:J $ radlonics Installation The D192C mounts inside the FACP enclosure. Depending on the configuration of the panel, it may attach using existing mounting holes or with a 0137 or 0138 mounting bracket. Using a Class B, Style W, 2-wire circuit, wire the D192C to the FACP according to the Installation Instructions supplied with the module. The D192C requires the following: . 12 V DC auxiliary power . Supervisory zone or point input . Alarm power input of 12 or 24 V DC . Panel common For UL applications, a listed (UTRZ) regulated power supply may be used to power Notification Appliances through the D192C To comply with NFPA standards: . The FACP and the power supply must be supervised or installed in the same room not more than 20 feet from the D192C as specified by NFPA . Wiring between the FACP and the power supply must be in conduit . Power supply fault conditions must be supervised by a UL-listed relay. Install according to the Radionics Installation Instructions. Test and maintain equipment according to the Instruction manual, NFPA 72, Local Codes, and the Authority Having Jurisdiction. Failure to follow these instructions may result in a failure to initiate an alarm condition. Radionics is not responsible for improperly installed, tested, or maintained products. @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012, USA (800) 538-5807 Specifications _III"""'''' ~ . . ,', . '1.""-1$ '~~jo ,~>"' < j-)/"'V:: ~ ".~ J"~'*f . ., . ,,'''4 - Operating Voltage 12 V DC supplied by FACP Auxiliary PONer and/or external power supply 12 V DC supplied by FACP alarm power supply, 12 or 24 V DC supplied by external power supply. Module is rated at 1.8 A @ 12 or 24 V DC 20mA 10mA 1.8A Alarm Output Voltage Idle Current Alarm Current Maximum Rating Dimensions (H x W x D) 5 in. x 3 in. x 1.5 in. (12.7 an. x 7.6 em. x 3.8 em.) Listings and Approvals . Underwriters Laboratories . CSFM . FM . MEA Ordering Information . ''k'" 'i;l' ~'~"<'" W~ ' -, ~ ~~:: ~ >-<;;-~~,<,::j:,~~ ':",,, '~1';l:'. ',', ~~~ ,_00;;, ...,,~ I~,'<I. ,c . ~.. ~ , ' . ". ~ - D192C Notification Appliance Circuit Supervision Module D9142F 24 V DC Auxiliary PONer Supply D137 Mounting Bracket D138 Mounting Bracket (for D9124) ~'JnO CE:UIFICATE N~. A5137 75-07081-000-D 8/01 Specifications D192C L522A Page 2 of 2 0928 Dual Phone Line Switcher Specifications Features . Dual Phone Une Switcher . Automatic switching to alternate phone line . D9124, D9412, D9412G, D9112, D7412, D7412G, D7212 CPU (Central Processing Unit) supervision . CPU failure annunciation . AC Status LED . Primary and alternate phone trouble LEDs . Communication fail LED Description Radionics' D9124, D9412, D9412G, D9112, D7412, D7412G, D7212 Control/Communicator panels use the D928 Dual Phone Une Switcher to transmit over an alternate phone line when the primary phone line is faulted. The D928 monitors the altemate line and the panel monitors the primary line. If a signal is generated and the panel senses that the primary phone line is bad, then it will attempt to use the alternate phone line to send the message. If trouble is detected, the panel keeps the faulty phone line in memory. If the primary line is found to be electrically faulty, the D928 switches to the alternate phone line and reports the fault The D928 uses the primary or alternate phone line to dial a primary, backup or duplicate phone number. When using Modem 11Ia2, the panel sends a phone line failure message to the D6500 or D6600 Receiver, indicating which phone line is in trouble. The panel sends two distinct messages for trouble on the primary or altemate phone line. The D928 also has a circuit that monitors the panel's CPU for proper operation. If the CPU fails, a buzzer on the D928 sounds as does a sounder in the panel. This sounder cannot be reset while the CPU is failed. Four LEDs mounted on the front edge of the D928 serve as status LEDs by displaying primary and altemate phone line failure, failure to communicate and AC power status. 0928 Dual Phone Une Swltcher Application All reporting fire alarm systems are required to have a primary and alternate means of transmitting reports to a receiver. Typical 0928 applications are schools, factories and care facilities where the ability of the system to relay information off-premises is especially critical for safeguarding life and property. Installation The D928 Dual Phone Line Switcher mounts inside the Control/Communicator enclosure. Mount the module to the inside of the enclosure as instructed in the appropriate Operation and Installation Manual. The D928 connects to the control/communicator through the interconnect wire provided. The ribbon cable attaches to the panel's accessory connector. The D928 is programmed at the control panel using the appropriate Program Entry Guide. Install, test and maintain this device according to its Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested or maintained. $ radionics A member of the Bosch Group Specifications Idle Current 18 mA@13.8 VDC Maximum Current 100 mA@ 13.8 VDC Operating Voltage 10.2 to 13.9 VDC supplied by the control/communicator Status Indicators LEDs indicate primary phone line fail, alternate phone line fail, failure to communicate and AC power status. Buzzer annunciates CPU failure. Wiring Connections Standard Modular Connections Dimensions (H x W x D) 5 in. x 3 in. x 3.8 in. (13 cm. x 8 cm. x 2 cm.) Weight 3.3 oz. (93.5 g) @ 2002 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012, USA (800) 538-5807 Listings and Approvals . Underwriters Laboratories . FM . NYC-MEA . CSFM Ordering Information D161 Dual Modular Phone Cord (7 ft. /2.1 m) Dual Modular Phone Cords (2 ft. / 6.1 m) Dual Phone Une Switcher D162 D928 mo~2 cg CERTIFICATE NO. A5137 75-07163-000-0 2/02 Specifications D928 L 1095 Page 2 of 2 08004 Transformer Enclosure Installation Instructions Description The D8004 Transformer Enclosure protects the AC plug-in transformer and ensures that it remains securely fixed to the AC wall outlet. The 08004 Transformer Enclosure may be required for certain applications, the most common being fire alarm. Consult your local Authority Having Jurisdiction (AHJ) for installation requirements. The D8004 is a direct replacement for the AE-TR16 Installation Instructions . Remove AC power and lock out the circuit breakers prior to installation. VOLTAGE 1- Mount the gang box to the wall or supporting structure. 2- Insert a gang box partition into the gang box. The partition will divide the gang box into two sections. The large section will contain the high voltage wiring; the small section will contain the low voltage wiring. 3- Punch out a conduit knockout in the high voltage side of the gang box. Bring the 110 V AC wiring through the knockout hole and into the gang box as required by the local Authority Having Jurisdiction, NFPA and the NEC. 4- Gonnect the isolated 110 V AC wiring to the duplex outlet. 5- Mount the duplex outlet to the cover plate using the #6 machine screws, nuts and lockwashers provided. Mount the cover plate to the gang box with the #10 screws provided with the gang box. 6- Energize the power to the circuit(s) and, using a volt meter, test the duplex outlet for proper voltage. 7 - Punch out a conduit knockout in the low voltage side of the gang box. Bring the low voltage wiring through the knockout hole and into the gang box as required by the local Authority Having Jurisdiction, NFPA and the NEC. 3- Connect the low voltage wiring to the transformer. 9- Plug the transformer into the bottom outlet of the duplex outlet. Secure the transformer to the duplex outlet using the screw provided. 10- Attach the cover to the cover plate with the four #6 self-tapping screws provided. G:m~ Box Du:>lex Outlet Cover ::Jlate --- --- o o o o o i- o~ ~- -- - Transbrmer Cover -- - - l!fI-' (t- o~ PIN 36564B AMCX.S1871 - Central Station Alarm Units Page 1 of rail Online Certifications Directory AMCX.S1871 Central Station Alarm Units Page Bottom Questions? Central Station Alarm Units Guide Information BOSCH SECURITY SYSTEMS INC SUITE 106 20 RAGSDALE DR MONTEREY, CA 93940 USA S1871 :r"1 o~, D8109, D8109G, D8109H or D8109L, enclosure; D8108A, or D8108AH, enclosure accessory; Q.,8004 L >rmer enclosure; D1252A control station; D125B powered loop interface; D127 relay module; D811 arm status relay modlule (covered under file BP8925) ; D268 zone control module with D269 arming/status module; Model D192C, D192G bell supervision modules, D-105-BL end ofline resistor assembly; D8114 quad serial interface; D8129 octo-relay; D8130 release module; D8131 printer/CRT interface; D8132 booster power supply; D8122 derived channel S.T.U.; Model D8125 expander module; D9127T, D9127UPOPIT Modules; D8128A eight zone protection transponder. Digital alarm communicator receivers, Models D6500, D6600. Digital alarm communicator receiver subassemblies: Models D6610 CPU Card, D6615 CPU Terminator Card, D6640 Line Card, D6641 Line Card, D6645 Telco Terminator Card for use with Model D6600. Model D636A control station with zone expander; Model D640 zone expander module. Central Station Burglar Alarm Use when used in conjunction with the P AL-200C. Models D9124, D9412G, D7412G, D7212G Control Units suitable for Central Station Applications, for use with Liste modules, separately Listed devices, accessories as described in the manufacturer's operations and installation manual to form a combination central station alarm unit. Suitable for Grade C Applications. Also suitable for Grade B when installed in conjucton with a Listed local sounding device, Grade AA when installed in conjuction with the Model D8122 dc;:rived channel subscriber terminal unit and for Grade AA Service when installed in conjunction with either the Model D9133TTL-E Network Interface Module or the Model C900TTL-E Dialer Capture Module communicating to the D66010 Digital Alarm Communicator Receiver. Suitable for use with Models D1256, D1257, Command Centers. ~ ~~1 D8125 MUX Expansion Module. - Combination control units, Models D2212B, D2212BE, D2412U, D2412UE, D2812, D28L12U, may be followed by suffix "LT" intended for use with other separately Listed devices as indicated in the instructions, wiring diagram to http://database.u1.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=AMCX.S 1871 &ccnsl.. 2/6/0 AMCX.S1l871 - Central Station Alarm Units Page 2 of form a Grade C, B or AA system. C~...trol unit subassemblies, Models D2212B, D2212BE, D2412U, D2412UE, D2812, D2812P and D28L12U, Ned by suffix "LC". Control unit accessories, keypads, Models D202A, D220A, D205, D222A, D223A; Models D621(*S), D621W(*S), D623(*S), D623W(*S), D625(*S), D625W(*S) for use with control panels indicated in the installation instructions. Models D720 and D1255, may be followed by suffixes R, TD, or W, for use with control panels indicated in the installation instructions (Covered under File S5579). Control unit accessories, relay modules, Models D 113 and D 134. Control unit accessories, zone expansion module, Model D208. Control unit subassemblies, zone expansion, Models D208LC, D8128C, D8128D. Control unit accessories for use with Access control modules, Models D9210B, D9210BC and D9210BLD (covered under file S5579). Control unit subassemblies, Model D8128C OctoPoPIT Module (covered under file S5579). Control unit accessories, printer interface, Models D9131, D9131A. For use with Radionics products where referenced in the installation instructions. '01 unit accessory, Network Interface Module, Model D9133TTL-E(covered under File S5579). Control unit accessories, Dialer Capture Module, Model C900TTL-E(covered under File S5579). Models D4412(*S) , D6412(*S), D6412LT Control units suitable for Central Station Applications, for use with Listed modules, separately Listed devices, accessories as described in the manufacturer's operations and installation manual to form a combination central station alarm unit. Suitable for Grade C Applications. Also suitable for Grade B when installed in conjuction with a Listed local sounding device, Grade AA when installed in conjuction with the Model D8122 derived channel subscriber terminal unit. Suitable for use with Models D621(*S), D621 W(*S), D623(*S), D623W(*S), D625(*S), D625W(*S) Command Centers. Control II nit accessory, RF Receiver, Models RF3224, RF3222. Suitable for use with transmitters indicated in the installation instructions. Controlllnit subassemblies, Models D6412LC, D6412M, D9529. (*S)Optional- Denotes compliance with ANSI/SIA CP-01-2000, "Control Panel Standard - Features for False Alarm Reduction" . Page To)> Notice of Disclaimer Questions? UL Recognized Components Products Certified for ~---~~~- Canada 'sted and Classified Products http://database.u1.comlcgi-bin/XYV/templateILISEXTIlFRAME/showpage.html?name=AMCX.S 1871 &ccnsl.. 2/6/0 AMCX.S 1871 - Central Station Alarm Units Page 3 of This page and all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ TIv.-~ Il.ppearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured l UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Ui' ..Jervice. Always look for the Mark on the product. UL permits lhe reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright @ 2004 Underw.riters Laboratories Inc.@" http://database.u1.comlcgi-bin/XYV/templateILISEXT/IFRAME/showpage.html?name=AMCX.S 1871 &ccnsI.. 2/6/0 0461 Manual Fire Alarm Box Specifications Features . Rugged die cast housing . 14 gauge Plated steel back plate · Single gang mounting . Corrosion resistant construction . 10 Amp 120 V AC contacts · Key locked reset · Screw terminal connections · Optional break glass rod · Latching pull down lever Description The Radionics' D461 Manual Fire Alarm Box is a single action, UL listed fire alarm initiating device. It has one set of normally open contacts rated for 10 Amps at 120 V AC. The D461 has an easily identifiable pull down lever and contains an integral break glass rod carrier. The 0461 is compatible with the following accessory devices: · D463 · D465 · D466 The unit is a high quality manual fire alarm box constructed entirely of non-toxic materials with a low profile and rounded edges to fit most design applications. All components are prepainted or have plated surfaces to inhibit corrosion. Non- corroding screw terminals are provided for wire connections to the D461. The D461 is manufactured in conformance with the standards set forth in the Americans with Disabilities Act. The D461 has a white pull down lever in its center. Pulling down the lever latches it into place. The D461's normally open contact switch is shorted causing an alarm on the fire initiating loop. The pull down lever can not be reset unless the correct key is inserted into the manual fire alarm box lock and the unit is opened. The latching lever can then be restored to its normal position. When the D461 is being reset and has a glass break rod installed, all debris must be removed priorto installing another rod to ensure the unit will close and lock securely. 0461 Manual Fire Alarm Box Application The D461 Manual Fire Alarm Box is an accessory device for Radionics control/communicators and is typically used in fire alarm applications. Manual fire alarm boxes are generally installed near building fire exits such as lobbies or stairways. Persons evacuating the building during an emergency are able to initiate an alarm by pulling down a lever. This alerts others who may still be inside. Schools, factories, offices, and health care facilities are typical applications. The snap lock feature of the D461 prevents the unit from being reset without a key so the origin of the alarm can be more easily determined. The 10 Amp. 120 V AC contact rating allows the D461 to handle larger current loads. This makes the unit an ideal choice for both new installations and retrofits. Installation The Radionics' 0461 Manual Fire Alarm Box is a UL listed fire alarm initiating device. The D461 is installed alone or with other approved mechanical devices on Radionics control/communicators. Manual fire alarm boxes must be installed according to codes set by the authority having jurisdiction. The D461 mounts to a standard flush or surface mounted single gang switch box or plaster ring. Slotted screw holes allow for correct positioning during installation. Two corrosion resistant screw terminals are provided for wire connections. All wiring and installation is subject to the authority having jurisdiction. Install, test and maintain this device according to the Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. ~ Radonics. Specifications 0461 Specifications Contact current rating 10 Amps at 120 VAC Dimensions 4.75 in. x 3.1875 in. x .875 in. (H x W x D) (12 em x 8 em x 2.2 em) To Fire Alar~ Control/Communicator Zone or Point EOL Resistor Listings and Approvals · UL listed . CSFM: approved Ordering Information Model Description D461 Manual Fire Alarm Box D463 Double-Action Cover D465 Glass Replacement Rod D466 Backbox, Red o ) 2 3 o ( ) D461 Wiring Connections o o ISO 9002 0 CERTJFlCATE NO. A5137 @ 2001 Radionics, a division of Detection Systems, Inc. @ The Radionics logo is a registered trademark of Radionics, PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 PIN: 75-06561-000-C Specification Sheet 03/01 D461 Page 2 of 2 0467 Weatherproof Manual Pull Station Specifications Features . Weatherproof Manual Pull Station . 10 A, 120 VAC contacts . Rugged die-cast aluminum housing . Neoprene sealing gasket . Corrosion-resistant construction . Hex reset . Latching pull-down lever . Screw terminal connections Description Radionics' D467 Weatherproof Manual Pull Station is a UL Listed fire alarm initiating device suitable for applications requiring outdoor mounting of the manual fire alarm pull station. The D467 is appropriate for applications where the manual pull station may be subject to wet conditions. The D467 consists of a die-cast aluminum back box, Neoprene sealing gasket and a special manual fire alarm box. The unit is a high quality pull station constructed entirely of nontoxic materials with a low profile and rounded edges to fit most design requirements. All components are pre-painted, or have plated surfaces to inhibit corrosion. The latching pull-down lever on the D467 requires a hex key to reset it. This allows only authorized personnel to reset the manual pull station so that the origin of the alarm can be determined easily. The D467 has one set of Normally Open contacts rated for 10 A @ 120 VAC, making the device suitable for installations involving large current loads. The D467 conforms with the Americans with Disabilities Act (ADA). 0467 Weatherproof Manual Pull Station Application Radionics' D467 Weatherproof Manual Pull Station is an accessory device for Radionics' control/communicators. Its weatherproof design allows outdoor fire alarm applications. The 0467 can be installed along with other approved devices on all Radionics fire alarm control/communicators. Manual fire alarm pull stations are generally installed near building fire exits such as lobbies or stairways. Upon evacuating the building during an emergency, a person can initiate an alarm by pulling down the lever. This action alerts others who may still be inside. Installation The 0467 is installed alone or with other approved mechanical devices on Radionics' control/communicators. Manual fire alarm pull stations must be installed according to codes set by the Authority Having Jurisdiction (AHJ). The 0467 mounts to the supplied back box. Insert two saews through the slotted holes and tighten down securely. Two corrosion-resistant screw terminals are provided for wire connections. All wiring and installation is subject to the AHJ. Install, test and maintain this device according to its Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested or maintained. $ radlonics A mem ber of the Bosch Group Specifications LContact Current Rating ! 10 A @ 120 VAC I ~_,~___..______.._.._.________L____~______l To Fire Alarm Control/Communicator zone or point Switch Listings and Approvals . Underwriters Laboratories . CSFM Ordering Information D467 Weatherproof Manual Pull Station D463 Double-Action Cover D465 Glass Replacement Rods ( 10 pack) 0467 Manual Station o o @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (BOO) 538-5807 ~ o ~ o 0467 Wire Connections 75-07162-OOO-C Specifications L1106 8101 0467 Page 20f2 UNIU.S5172 - Boxes, Non-coded Page 1 of raI Online Certifications Directory UNIU.S5172 Boxes, Non-coded Page Bottom Questions? Boxes, Non-coded Guide Information BOSCH SECURITY SYSTEMS INC SUITE 106 20 RAGSDALE DR MONTEREY, CA 93940 USA S5172 l"dels D325, D461, D461B, D461G, D461Y, D462, D467. - - Mooel D325A for use with D8024, D9024, D 1 0024 control panels. Model D462 for use with D7112, D7212, D8112, D8124, D9112, D9124, D7412 or D9412 control panels. Model D7045 for use with D7024 control panel. Page Top Notice of Disclaimer Questions? UL Recognized Components --.-.-- Products Certified for Canada UL Listed and Classified Products This page and all contents are Copyright ~ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listilngs (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The state:ment "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adiacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright ~ , - Tnderwriters Laboratories Inc.@" http://database. u1.comlcgi -binlXYV Itemplate/LISEXT II FRAMEIshowpage.html?name=UNIU .S5172&ccnsht, 2/9/0 07038 Remote NAC Power Supply Specifications Features . Remote NAC Power Supply with 6 A of notification power . Outputs can be configured for NAC output or constant auxiliary power . 4 Class S, Style Y Circuits · Multiple output patterns · Ground fault indication · Over voltage indication . Regulated 24 V output (nominal) · Over current protection · Charger control monitor · Supervision of AC, battery and circuit expander . Fully supervised outputs · Compatible with the following Radionics controls: D7022 FACP, D7024 Fire Alarm Control/Communicator and the D8024, D9024 and 010024 Analog FACPs Descri ption The Radionics D7038 Remote Notification Appliance Circuit (RNAC) Power Supply is UL Listed to be used in commercial fire alarm applications. This regulated power supply provides up to six amps of power that are used to recharge batteries and operate both continuous and intermittent alarm loads. This six amps of power can be distributed through the four Class B, Style Y circuits that are part of the D7038. It is also compatible with any UL Listed control unit utilizing reverse polarity supervised notification outputs using 24 VDC regulated outputs. The D7038 is provided in a red enclosure that houses the power supply board and standby batteries. Ample room is provided inside the enclosure to make AC power connections and route field wiring to connection points on the power supply board. All wiring is connected to the power supply board via screw terminals that can accept up to #12 AWG (2.3 mm) wire. The D7038 can be connected to the D7024 via the four wire connection to the Option Bus. This connection provides individual control of each output by the D7024, and complete supervision of the power supply. The following options can be set with the DIP switches: Option Bus Address, NAC Input Variable and AC Failure Time Delay. The NAC Input Variable option allows for split functioning of the D7038's inputs. Input 1 can either be set to drive all four NAC outputs, or NAC Outputs 1 and 2. If the latter option is chosen, then Input 2 will drive NAC Outputs 3 and 4. There are seven local status display LEDs on the 07038 board that monitor the following conditions: High Voltage, AC OK, Low Battery, Loop Trouble, Ground fault, Output Active and NAC Short. 07038 Remote NAC Power Su Application The D7038 is designed to add four additional notification appliance circuits (NfPA 72, Class B, Style Y) to a fire alarm control panel. The D7038 can be used with other fire alarm control panels. Supervision and control is provided through a supervised, polarity reversal output (depending on the panel that is in use). For the D8024, 09024 and D10024 analog panels, the 07038 connects through a NAC circuit. No serial bus connection is necessary. The D7038 can also be used as a power supply for fire- protective signaling systems. Installation The D7038 power supply board and enclosure are shipped in one box. The D7038's enclosure should be mounted in a convenient location for servicing and maintenance. The power supply board must be mounted in the enclosure using the provided hardware. Primary power (120 VAC) from an unswitched dedicated branch circuit is routed to the power supply enclosure and connections are made inside. field wiring to control modules or continuously powered devices are routed into the enclosure via knockouts provided on the enclosure. When all circuits are determined to be free of earth grounds and wire-to-wire shorts, connect the primary power to the supply and then install the batteries in the locations provided in the enclosure. $ radionics A member of the Bosch Group Specifications Operating Temperature +320F to +120oF (OOC to +490C) 120 VAC, 60 Hz, 2.5 A 24 VDC, nominal (20.2 to 28.0 VDC) Input Power Battery Voltage Max. Battery Capacity Output Voltage (AC Operation) Output Voltage (DC Operation Total Ouput Current Ripple Voltage 38Ah 27.4 +/- 0.1 VDC @ 250C (77"F) 24.1 +/- 0.6 VDC @ 250C (770F) 6A :S; 250 mVpp 14.8 in. W x 20.4 in. H x 4.1 in. D (38 em W x 52 em H x 10.4 em D) Enclosure Dimensions (w/o door) Input Voltage 9 to 30 VDCNRMS Input to Output Response Time :S; 50 ms EOL Resistor User supplied Standby Voltage -5.0 VDC EOL Resistor 2.2K ohms +/- 5% Output Voltage Rated Output Current (per output) x 4 24.1 or 27.4 VDC) 1.5A Max. Output per Circuit Max. Output for All Circuits 2.5A 6.0 A Local Status Display LEDs Max. Output Current 850 mA Contact Rating 1.5 A @ 32 VDC Listings and Approvals . UL 864 Listed Control Unit Accessory · UL1481 Listed Power Supply for Fire-Protective Signaling Systems · CSFM · NYC-MEA Ordering Information 0126 12 V, 7 Ah Battery 12 V, 24 Ah Battery 12 V, 38 Ah Battery 01224 01238 07038 Remote NAC Power Supply AC Power Tel1Tlinals Red 07038 Remote NAC Power Supply Board 1809002 m CERTIFICATE NO. A5137 @ 2003 Bosch Security Systems 130 Perinton Pkwy Fairport, New York 14450 Customer Service: (888) 538-5807; Technical Support (888) 886-6189 PIN: 38788E Specifications L960 05103 D7038 Page 2 of 2 UTRZ.s5603 - Power Supply Units Page I ofl BI o n line Ce rtifications 0 i rectory Page Bottom UTRZ.S5603 Power Supply Units Questions? Power Supply Units Guide Information BOSCH SECURITY SYSTEMS INC SUITE l06 20 RAGSDALE DR MONTEREY, CA 93940 USA S5603 Non regulated, power limited power supply-battery chargers, Models D703~, D9142F. R"'edlated, power limited power supply-battery charger, Model D9079. *Model D7038 is covered under File S5579. Page Top Notice of Disclaimer Questions? UL Listed and Classified Products UL Recognized . Components Products Certified for Canada This page and all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service:. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statc~ment "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright @ 2004 Unde:rwriters Laboratories Inc.@" http://database. u1.com/cgi -binlXYV /template/LISEXT /1 FRAME/showpage.html?name=UTRZ.S5603 &ccnshor 4/2/04 0411,0412 Synchronization Modules Specifications Features · Synchronization modules for Class A and Class B alarm circuits · Compatible with Radionics D500 Series Horn/Strobes · Independent control of audible alarm while maintaining visual alarm on two-wire or four-wire Notification Appliance Circuit (NAC) · Operates on 12 or 24 VDC · Converts two independent inputs, strobe and audible, into a single notification appliance output · Conforms with ADA synchronization guidelines for strobes and audible Temporal Code 3 output · Supervision of Synchronization Module(s) by the Fire Alarm Control Panel (FACP) Description Radionics' D411 is a 12/24 VDC module that synchronizes notification appliances on Class B alarm circuits. Radionics' 0412 is a 12/24 VDC module that synchronizes notification appliances on a single Class A or two Class B circuits. These devices provide an effective means of synchronizing both audible and strobe circuits. Audible devices controlled by these modules provide a synchronized Temporal Code 3 output. This means that the Code 3 pattern produced by all horns on that circuit is synchronized and the temporal pattern effect mandated by NFPA 72 (July, 1996) is clearly recognizable. Synchronizing strobes can eliminate possible restrictions on the number of strobes in the field of view. This is an easy way to comply with ADA recommendations concerning persons with photosensitive epilepsy. Both the two-wire and four-wire modules offer the ability to provide independent operation of audible notification appliances while maintaining the visual alarm condition, a required feature in some jurisdictions. The D412s may be interconnected to provide temporal (Code 3) horn and strobe synchronization with multiple circuits. By using existing wiring, these modules also provide an economical method of upgrading existing two- or four-wire circuits to comply with new regulations. Front View of Synchronization Module Application Radionics' D411 and D412 Synchronization Modules are used in Notification Appliance Circuits to control synchronization of audible and visual devices. They bring visual strobes into synchronization with an output of one flash per second and audible devices into compliance with NFPA 72, temporal sound pattern (Code 3). They provide a cost effective means to upgrade existing circuits to ADA compliance. The 0411 and 0412 Synchronization Modules operate on notification appliance circuits with continuously applied voltage. Installation The D411 flush or surface mounts to a 4 in. x 2 -1/8 in. back box; the D412 flush or surface mounts to a 4-11/16 in. x 2-1/8 in. back box. Notification appliance outputs from the control panel connect to the modules and outputs from the modules connect to the notification appliance circuit. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. $ radionics A member of the Bosch Group "' Specifications Electrical Specifications 0412 Current Requirements Circuit Class 6, 2-wire Class A or Class 6, Configuration 4-wire 10.5 VDC 15mA 3mA 112mA 3mA 299 mA 53mA Rated Input 10.5 to 31.0 VOC 12.0 VDC 16mA 4mA 117mA 4mA 352 mA 65mA Voltage 24.0 VDC 30mA 8mA 130 mA 8mA 662 mA 118mA 12 VDC 14mA 20mA Operating Current 31.0 VOC 40mA 10mA 138mA 10mA 831 mA 152 mA 24 VDC 10.5 VRMS 25mA 10mA 158mA 10mA 416mA 68mA Operating Current 25mA 38mA 12.0 VRMS 27mA 11 mA 158mA 11 mA 479 mA 83mA Output Current 3A 3 A1circuit 24.0 VRMS 44mA 22mA 194mA 22mA 838 mA 138 mA Temperature +320F to + 1200F (OOC to +49OC) 31.0 VRMS 54mA 28mA 218mA 28mA 1.111 A 213mA Range @ 85% RH Dimensions 1.4 x 4.3 x 4.3 in. 1.4 x 5 x 5 in. Listings and Approvals (HxWxO) (3.6 x 11 x 11 cm) (3.6 x 12.7 x 12.7 cm) . UL 0411 Current Requirements · CSFM · NYC-MEA Ordering Information ~~ 10.5 VDC 8mA 4mA 32mA 4mA 32mA 4mA 12.0 VDC 9mA 5mA 36 mA 5mA 34 mA 5mA 24.0 VDC 15mA 10mA 74 mA 10mA 62mA 10mA 31.0 VDC 18mA 12mA 90mA 12mA 78mA 12mA 10.5 VRMS 14mA 6mA 66mA 6mA 58mA 6mA 12.0 VRMS 15mA 7mA 72mA 7mA 66mA 7mA 24.0 VRMS 30mA 13mA 108 mA 13mA 78mA 13mA 31.0 VRMS 40mA 17mA 122 mA 17mA 86mA 17mA D411 Single Circuit Class B Sync Module D412 Dual Circuit Class A Sync Module D558S 24 VDC, 75 cd, Mini-Horn/Sync Strobe D559S 24 VDC, 15/75 cd, Mini-Horn/Sync Strobe D560S 12 VOC, 15 cd, Mini-Horn/Sync Strobe 0561 S 24 VDC, 15 cd, Mini-Horn/Sync Strobe D562S 12 VDC, 15/75 cd, Mini-Horn/Sync Strobe D571S 24 VDC, 15/75 cd Horn/Strobe D572S 24 VDC, 110 cd Horn/Strobe D573S 24 VDC, 30 cd Hom/Strobe 0574S 24 VDC, 75 cd Horn/Strobe 0575S 12 VDC, 15 cd Horn/Strobe D576S 12 VOC, 15/75 cd Horn/Strobe 0579S 24 VOC, 15 cd Horn/Strobe, Ceiling, White 0580S 24 VOC, 30 cd Hom/Strobe, Ceiling, White 0581S 24 VOC, 75 cd Hom/Strobe, Ceiling, White 0582S 24 VDC, 100 cd Horn/Strobe, Ceiling, White @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 349030 Specifications L845 5/01 Synchronization Modules Page 2 of 2 These multi-candela strobes provide intensities of 15 cd, 30 cd, 75 cel, 95 cd (ceiling-mount) and 110 cd (wall-mount). They can be synchronized when used in conjunction with Bosch Secul'ity Systems' D411 (2-wire) and D412 (4-wire) Synchronization Modules or compatible control panel. Synchronized strobes can eliminate possible restrictions on the lumber of strobes in the field of view. When synchronized, these strobl3s comply with ADA requirements concerning photosensitive epilepsy and meet the requirements of N FPA 72. . Series Features . 24 VDC with new UL Regulated voltage range of 16 VDC to 3::1 VDC using filtered DC or unfiltered FWR voltage . Strobes available in 15 cd, 30 cd, 75 cd, 95 cd (cI3iling-mount), or 110 cd (wall-mount) . Strobes produce 1 flash per second over the regulated voltage range . ADAlNFPAlANSI compliant . Zero inrush above peak . Compatible with Bosch Security Systems' D411 and D412 Synchronization Modules . Fast installation with In/Out screw terminals using #18 AWG to #12 AWG (1.2 mm to 2.3 mm) diameter wire . Series Listings, Certifications, and Approvals Listings and Approvals UUKC: Signaling Appliances and Equipment for Hearing Impaired (UL 1971) Complies with: ADA ANSI 117.1 FCC Part 15, Class B OSHA 29 Part 1910.165 NFPA 72 UFC Trademarks Lexan@ is a registered trademark of General Electric Corporation, USA in the United States and/or other countries. . Series Application Information Compatible Control Panels For synchronization, these strobe appliances are compatible with the D7024 FACP or other Bosch panels using a D411 or D412 Synchronization Module. Mounting Considerations These strobe appliances employ an integral strobe mounting plate for mounting to the indicated back boxes for the indicated applications: Conduit Surface Flush Applications Mounted Mounted Single-gang . Double-gan9 . . 4-in. square . 100-mm European . 0403 (BB-R) . . SHBB-R . All models have an attractive cover plate for a clean, finished appearance. Wiring Note: These strobe units are not recommended for use in coded or pulsed signaling circuits. The input terminals accept wires with diameters between #18 AWG and #12 AWG (1.2 mm and 2.3 mm). BOSCH . Series Technical Specifications . Series Hardware Accessories Standard steel back box with knockouts for interior surface mounting, concealed conduit mountin9, or semi-flush applications. Measures 4 in. (10.2 cm) square by 1.5 in. (3.8 cm) deep. . Used in Notification Appliance Circuits to control synchronization of audible and visual devices. 0411 is a 12/24 VOC module that synchronizes notification appliances on Class 8 alarm circuits and brings visual strobes into synchronization with an output of one flash per second and audible devices into compliance with NFPA 72, temporal sound pattern (Code 3). . ~ ~:: ;'o:~..f:.;',~~~~ ,:~. i<'~ ~~:~::4;~_~'~~~.~.-~~'.'~~:,:;:;J ~i- J;>:~,;;-"t:r~~~ . Used in Notification Appliance Circuits to control synchronization of audible and visual devices. 0412 is a 12/24 VOC module that synchronizes notification appliances on a sin91e Class A or two Class 8 circuits and brings visual strobes into synchronization with an output of one flash per second and audible devices into compliance with NFPA 72, temporal sound pattern (Code 3). Red, metal back box that measures 5 in. (12.7 em) square by 1.56 in. (4 em) deep. ;;:~c :-,~,._" E:~D",7,>7-~} Prod. 10 OS24-VARC-SWR This square, red, wall-mount, multi-candela strobe provides four light output intensities (15 cd, 30 cd, 75 cd, or 110 cd) in one unit. . Listings, Certifications, and Approvals Listin9s and Approvals: CSFM: 7125-0801 :180 . Technical Specifications 15 cd, 30 cd, 75 cd, or 110 cd 15 cd = 67 mA; 30 cd = 108mA; 75 cd = 209 mA; 110 cd = 275 mA 15 cd = 47 mA; 30 cd= 81 mA; 75 cd = 12~ mA; 110 cd = 166 mA 15cd = 40 mA; 30 cd = 62 mA; 75 cd = 92 mA; 110 cd = 128 mA ,; ::}_; "~'" $ _ :~.'< _', ";'~ ~:.~.~:,',,', '.=': ?z.~-:., f::-',:",~H ~."~ '.~ ~r_",K;::-'''''''''::~;, "'"' ...~. ,~i(..lf~':4t$;~"~ ~,J"t\/"~ r ;~f":H' 1,< ~ ,(t/i":11" ,:1''"" ~ ",~.: ' "~~~I~~ v ) ,i;e"; '~~~~f~l \~ .~~' "~!l t~\.,~~,:. :~ J';o~~".- t" t, ,,~~~~i \~:~ ,~ ::: :"'-/~/~: ~~-:-,:""::".._~~,~~~,." ~1':: ''''~.?,~':, ~:'>1'<I.}~.~,fl P"'-~"":.:/-:' -::',---~' .'" "-~',' -: '" ",- " : ,.,:,' :~:::'-' (, ~,' ,. Prod. 10 RS$-24MCC-FW Prod. 10 RSS-24MCCR-FW This square, white, ceiling-mount, multi-candela strobe provides four light output intensities (15 cd, 30 cd, 75 cd, or 95 cd) in one unit. This round, white, ceiling-mount, multi-candela strobe provides four light output intensities (15 cd, 30 cd, 75 cd, or 95 cd) in one unit. . Technical Specifications . Technical Specifications 15 cd, 30 cd, 75 cd, or 95 cd .."r."~;-""""--~~: _,...~_~_.. L ~" -- \- 15 cd = 6S mA; 30 cd = 112 mA; 75 cd = 211 mA; 95 cd = 292 mA 15 cd = 68 mA; 30 cd = 112 mA; 75 cd = 211 mA; 95 cd = 292 mA 15 cd = 45 mA;30 cd = 72 mA; 75 cd = 128 mA; 95 cd = 171 mA 15 cd = 45 mA; 30 cd = 72 mA; 75 cd = 128 mA; 95 cd= 171 mA 15 cd = $5 mA; 30 cd = 52 mA; 75 cd = 89 mA; 95 cd= 118 mA 15 cd = 35 mA; 30 cd = 52 mA; 75 cd = 89 mA; 95 cd = 118 mA Jsch Security Systems 130 Pe,rinton Parkway Fairport NY 14450-9199 Phone: (800) 289-0096 Fax: (585) 223-9180 www.boschsecurity.us Specifications are subject to change without notice 46838D DAS24-VARC Series Multi-Candela Audible Strobes Specifications Features . 24 VDC Wall-mount Multi-Candela Audible Strobes . Field-selectable candela settings (15, 30, 75 or 110 cd) . Selectable Continuous Horn or Temporal (Code 3) . Three selectable dBA settings in both tones . ADA, NFPA, ANSI compliant . Compatible with Radionics' D411 and D412 Synchronization Modules . Cost-efficient two-wire operation . Low average current draw . Zero inrush current . Easy wiring via screw terminals . Low profile design Description Radionics' DAS24-VARC Series of Multi-Candela Audible Strobes offers four field-selectable candela settings (15, 3D, 75 or 110 cd) and a selectable choice of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable settings for dBA levels to choose from. These notification appliances can be synchronized when used in conjunction with Radionics' D411 (two-wire) and D412 (four- wire) Synchronization Modules. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Radionics' synchronized strobes comply with ADA requirements concerning photosensitive epilepsy. The audible may also be silenced while maintaining strobe activation. The DAS24-VARC Series is designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UL 1971, UL 464 as well as meeting ADA recommendations concerning photosensitive epilepsy. DAS24-V ARC-SWR Multi-Candela Audible Strobe --~. . ..-:..:._ :__ _ '._4":';._.w,...:~:-- ..... ~-":'-:-",~.."" -- . - -- - -. ~"~~_. .---- Multi-Candela Indicator (bottom of strobe lens) Application Radionics' DAS24-VARC Series of Multi-Candela Audible Strobes will satisfy virtually all requirements for indoor, wall- mount applications. The option to silence the audible allows emergency personnel to communicate while maintaining the visual alarm condition, a requirement in some jurisdictions. These audbile strobes provide a way to alert hearing impaired persons of an alarm condition, and are well-suited for areas of public gathering such as stores, schools, hospitals, nursing homes and offices. Installation All inputs are supervised and employ IN/OUT screw terminals for quick installation using #12 AWG (2.3 mm) to #18 AWG (1.2 mm) wire. The low profile design of these audible strobes incorporates a universal mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic one-screw grille cover. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. $ radionics A member of the Bosch Group Specifications Electrical Specifications DAS24-VARC dBA Ratings Regulated Input Voltage 16.0 to 33.0 Range (VDC/FWR) Strobe Candela (cd) 15,30,75,110 Mounting Wall Color Red White Shape Square DAS24-VARC Series Current Ratings. (Amps) 16 0.081 0.128 0.225 0.296 0.068 0.105 0.157 0.207 24 33 0.068 0.090 0.119 0.157 Rated Average Curre,nt wI LOi.V~~~I"g , .....--.. . -.....-.. .,........ .. ....,...." _.,-,;,'" }-...,.....,..,.,.-,.'..,....'"....'.. 16 0.077 0.119 0.222 0.294 24 0.060 0.090 0.142 0.200 33 0.055 0.081 0.109 0.147 Continuous Horn High 91 99 Medium 88 95 Low 83 90 High 87 99 Medium 84 95 Low 79 90 Code 3 Horn Listings and Approvals . UL Ordering Information OAS24-V ARC-SW- R OAS24-V ARC-SW- W 24 VDC Multi-candela Audible Strobe, Wall-mount, Red 24 VDC Multi-candela Audible Strobe, Wall-mount, White 0411 Two-wire Synchronization Module 0412 Four-wire Synchronization Module * Average Current per actual production testing @ 24 VDC D XX ~ ~ XX-XXXX-~ ~ ~ 1st letter is always UD:=j" I ~COlor W: White R: Red Letter/Letter Combo A: Hom Mountina S: Strobe W: Wall V: Speaker C: Ceiling C: Chime 0: Outside MA: Mini-ham Shaoe B: . Bell. S: Square MT. Multi-tone R: Round RS: Retrofit Strobe Letter (ootional) S: Strobe Number (ootional) 4: Four-wire Voltage (DC)/Wattage Understanding the Model Number Code @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 Candela ratina VARC: Variable candela 46836C Specifications Sheet L1 098 8/01 DAS24-VARC Page20f2 DAS24-75-S0R Weatherproof Audible Strobe Specifications Features . 24 VDC Weatherproof Audible Strobe . Selectable Continuous Horn or Temporal (Code 3) . Two-wire connection . ADA, NFPA. ANSI compliant . Compatible with Radionics' D411 and D412 Synchronization Modules . UL Listed for Outdoor Use (Temperature range -310F to +150oF, -350C to +660C) . Compatible with WPBBR-HS Weatherproof Back Box . Low average current draw . Zero inrush current Description Radionics' DAS24-75-S0R Weatherproof Audible Strobe is a two-wire notification appliance that offers a field-selectable choice of continuous horn or temporal pattern (Code 3) when constant voltage from the Fire Alarm Control Panel (FACP) is applied. The option to silence the audible allows emergency personnel to communicate while maintaining the visual alarm condition, a requirement in some jurisdictions. The extended temperature range ratings of -310F to +150oF (-350C to +660C) will satisfy all severe-weather outdoor applications. The strobe uses a Xenon f1ashtube enclosed in a rugged Lexan@ lens to provide maximum reliability for effective visual signaling. The DAS24-75-S0R can be synchronized when used in conjunction with Radionics' D411 (two-wire) and D412 (four- wire) Synchronization Modules. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Radionics' synchronized strobes comply with ADA requirements concerning photosensitive epilepsy. This audible strobe is compatible with the WPBBR-HS Weatherproof Back Box. WPBBR-HS Weatherproof Back Box DAS24-7S-50R mounted to WPBBR.HS Application Radionics' DAS24-75-S0R provides high audio output with clear audibility, and is designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. This notification appliance provides a way to alert hearing impaired persons of an alarm condition, and is well-suited for areas of public gathering such as stores, schools, hospitals. nursing homes and offices as well as outdoor applications. It is designed for maximum performance, reliability and cost- effectiveness while meeting or exceeding the latest of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), UL Standard 1638 (Standard for Outdoor Signaling Devices) and UL 464 (Audible Signaling Devices). Installation All inputs are supervised and employ IN/OUT screw terminals for quick installation using #12 AWG (2.3 mm) to #18 AWG (1.2 mm) wire. The design of this notification appliance incorporates a built- in universal mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic one-screw grille cover. Install, test and maintain this device according to its Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. $ radionics A member of the Bosch Group Specifications General Specifications Operating Voltage 24 VDC Strobe Candela (cd) 75 VDC Regulated Input 16.0 to 33.0 Voltage Range VDC/FWR Area of Usage Indoor (per UL 1971)/ Outdoor (per UL 1638) Operating Temperature -310F to +150oF (-350C to +66OC) Maximum Humidity 95% Mounting Wall Shape Square Color Red Average Current (Amps) for Audible Strobe* 16.0 24.0 . Voltage (VElC) 33.0 0.145 0.104 0.098 . Average Current per actual production testing at listed VDC. See installation instructions for rated average and Peak current across the UL Listed voltage range for both filtered DC and unfiltered FWR. dBA Ratings for Audible Strobe Continuous Hom High 91 99 Medium 88 95 Low 82 90 High 85 99 Medium 82 95.5 Low 75 90 Code 3 Horn Listings and Approvals . UL Ordering Information OAS24-75-S0R 24 VOC, 75 cd Weatherproof,Two- wire, Audible Strobe, Wall-mount, Red WPBBR-HS Weatherproof Back Box, Red 0411 Two-wire Synchronization Module 0412 Four-wire Synchronization Module 1 st letter is always "0" ...~ I Letter/Letter combo.---J A: Horn S: Strobe V: Speaker C: Chime MA: Mini-horn B: Bell MT: Multi-tone RS: Retrofit Strobe Q XX ~ ~ XX-XXXX.~ ~ ~ I L. ~Ior W: White R: Red MountinQ W: Wall C: Ceiling 0: Outside Shaoe Square Round Letter (ootional) S: Strobe Number (ootional) 4: Four-wire Voltage (OC)/Wattage Understanding the Model Number Code S: R: Candela ratinQ VARC: Variable candela @ 2001 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 47095C Specifications Sheet 8/01 DAS24-75-S0R Page 2 of2 These motor bells (D440, D441 , D442, and D443) use a high- quali1y, micro-motor operating mechanism. This provides long-term reliability, low starting voltage, and extremely low current conslJmption. These features enable the use of more bells per circuiit and greater alarm signal distribution than conventional bells. The low starting voltage provides a stronger signal on larginal circuits. These motor bells eliminate the coils and contacts found in convl~ntional vibratory bells. They contain a highly-efficient DC motor drive system to produce high sound pressure levels at lower current requirements. As a result, they reduce EMI generation problems. The operating mechanism is enclosed in a die-cast aluminum housling, making the bells suitable for both interior and exterior applications. The steel gong and striker last longer and produce a 10udElr sound output. . Series Features . High sound output for improved alerting capabilities . High ~fficiency, low current motor . Low starting voltage . Fully enclosed mechanism . Durable keyed steel gong and striker . Polarized for use on supervised circuits . Both 6 in. (15.2 cm) and 10 in. (25.4 cm) shell sizes in 12 VDC or 24 VDG.models . Integral EMI suppression . Mounting options include surface, flush, semi-flush, and exterior . Operates on filtered or unfiltered DC . Series Listings, Certifications, and Approvals Listings and Approvals: ULSZ: Audible Signaling Appliances (UL484) CSFM: 7135-0801: 119 NYC/MEA: 291-94-E Complies with: Factory Mutual Research NFPA 72 . Series Application Information Current Rating The peak current of all Bosch Security Systems' Motor Bells is approximately four times the rated current. This peak current surge exists for approximately 6 ms and must be supplied by the system power supply to ensure start-up of all devices. If the system power supply does not have sufficient surge capability (generally provided by large filter capacitors), loading of the supply should be based on the DC bell peak requirements rather than their rated current. Mounting Considerations Outdoor or Severe Environment Applications For an outdoor application or a severe environment (N EMA 3R) application, these motor bells in combination with a WBB-R Weather-Resistant Back Box must be mounted on a flat wall such that the wall covers the entire rear surface of the back box. The back box must have its drain holes pointed toward the ground. The knockouts in the rear surface of the back box must remain intact. The knockout hole on top of the back box is sized for a O.5-in. conduit and matching connector. A proper watertight conduit fitting must be used. BOlCH".'. .' " " '. . . .' ". - . ". .~ .... ..... .,' ." '... Y' ...........' .... ..... " ...... . .,. . . Indoc,r Applications These motor bells can also be used for inside applications by moun1ling them directly to the indicated back boxes for the indicated applications: Conduit Surface Flush Applications Mounted Mounted 4-in. square . 4-in. square, deep . 100-rnm European . BB-R . . WBB-R . . Use CIS Combination Appliance Where combination appliances are required, these Motor Bells can be used with the D556S (15/75 cd) Strobe Retrofit Plate that is designed to meet or exceed the latest requirements of NFPA 72, ANSI 117.0 and UL 1971. The bells and retrofit strobe are also compatible with the SBL2-R Retrofit Device Back Box. Wiring All Bosch Security Systems' Motor Bells are polarized for use on supervised Notification Appliance Circuits (NAC). All units are provided with four 6 in. (15.2 cm), #18 AWG (1.2 mm) color- coded leads to meet UL requirements and ensure correct polarity of NAC wiring connections. . Series Technical Specifications 92 dB at 10 ft. (3 m) . Series Hardware Accessories Standard steel back box with knockouts for interior surface mounting, concealed conduit mounting, or semi-flush applications. Measures 4 in. (10.2 cm) square by 1.5 in. (3.8 cm) deep. - -~ - - -".' . ,'-' ... ~. " I . , ~ A 15/75 cd strobe plate for retrofit applications. :-: -;. -. - '. - ~ -" - ~ ":-:' <:: :' ~-'~ :- ': - " - A red back box with dimensions (HxWxO) 10.9 in. x 6.1 in. x 1.7 in. (27.8 cm x 15.5 cm x 4.3 cm) for retrofit use with the 0556S Strobe Plate. ;~~':"':_''''''' """'__-~,..~_~~~..._ ~~"-;'_~:,,"'_ :~J"~.~"":"_'" ~ .'~""'" -, 'I ~ " ' >" " ,...~ " -" { Required for outdoor or severe environment applications. Measures 4.125 in. (10.5 cm) square by 2 in. (5.1 cm) deep. " _" '_;".\' ~,: 7-:','~.;,~ ~'1r," ,':,.."'..~::.'_.~'.:' ~"""'. ~,:",:,.;:\<t;~:o.~(rj; Prod. 10 0440 . Specifications \-:::'.~:.......-~--,....-'~~ ~ >' - ..., ~ 12 VDC nominal; 9 VDC to 15.6 VDC operating range ": : :.::l.,l/{:>c~~.~.=:~"'~., :;.~::~:~~;;/:.~'" :-::>,.~:~~: ::,:~~:':"I~'~,:;:::~. Prod, 10 0441 . Specifications 24 VOC nominal; 18 VOC to 31 VDC operating range ~_:~;:,~..~ ~~r.. ~ ~~1..,. r~::~ ~~~~:~,~::::~(,-.t::~_.~~ ' "'_ ',~, I. ~ '". Prod. 10 0442 . Specifications 12 VOC nominal; 9 VOC to 15.6 VOC operating range ~ >~'(':' 7): :.~~ T~'. />T:-":"..1~;.-::~~- _~:.:..~~ ?,~;:' "";'2'::':,;- Prod. 10 0443 . Specifications .... ~ _ ,.,.. />-. J ~ ~ . _....,... ,",'" .... ~ - ~- - - ~. 24 VOC nominal; 18 VOC to 31 VDC operating range ;ch Security Systems J Pe,rinton Parkway Fairport NY 14450-9199 Phone: (800) 289-0096 Fax: (585) 223-9180 www.boschsecurity.us Specifications are subject to change without notice 75-06432-000-D ULSZ.S3391 - Audible Signal Appliances Page 1 of2 -- Online Certifications Directory Page Bottom ULSZ.S3391 Audible Signal Appliances Questions? Audible Signal Appliances Guide Information BOSCH SECURITY SYSTEMS INC SUITE 106 20 RAGSDALE DR MONTEREY, CA 93940 USA S3391 Accessories, Models 407, D400, D401, D402, D403, D404, D406. Ac",~ssories, Models D411, D412 for use with horn/strobes. - Audible/multi-candela strobe, Model ~ followed by 75 or V ARC, followed by ~, ~ or SWW. For wall mount, indoor use. Chimes: For private mode only (a), Models DCS24- V ARC-SWR, DCS24-V ARC-SWW. Horns, Models D448, D448W, D449, D449W, DMAI2, DMA24 followed by SWR or SWW, . For indoor use only. Horns, Models D539S , D541S, D542S, D543S. Horn/multi-candela strobe, Model DMAS24 or DMAS424 followed by V ARC, followed by SWR or SWW. For wall mount, indoor use. Horn/strobes, Models D558S, D559S, D560S, D562S, D570S, D571S,D574S,D576S, D579S, D580S, D58lS, D582S, DAS24-75-S0R. Motor bells, Models D440, D441, D442, D443. Suitable for outdoor use with WBB back box. Multi-tone horns, Models D457. p. . ~ horns, Models D424A, ,. Intended for indoor use and nonsleeping areas. Strobe horns for the hearing impaired, Models DMTS24-75-S0R. http://database.u1.comlcgi -binlXYV Itemplate/LISEXT II FRAME/showpage.html?name=ULSZ.S3391 &ccnsht.. 4/2/04 ULSZ.S3391 - Audible Signal Appliances Page 2 of2 (a)-These~ units must be set at max volume for Fire Alarm Service, Private Mode per NFPA 72G. ~e Top Notice of Disclaimer Questions? UL Listed and Classified Products UL Recognized Components Products Certified for Canada This page and all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright @ 2004 Underwriters Laboratories Inc.@" http://database. u1.com/cgi-binlXYV /template/LISEXT /lFRAME/showpage.html?name=ULSZ.S3391 &ccnsht.. 4/2/04 Models Available Two-Wire Models 2WTA-B 2WTR-B 2-wire with thermal and sounder 2-wire with thermal and Form C relay Four.Wire Models 4WTA-B 4WTR-B 4WTAR-B 4WITAR-B 4-wire with thermal and sounder 4-wire with thermal and Form C relay 4-wire with thermal, sounder, and Form C relay 4-wire with isolated thermal, sounder, and Form C relay Accessories RRS.MOD 2W-MOD2 SENS-RDR RT A 77-AB2 Product Overview Reversing relay/synchronization module 2-wire loop test/maintenance module Sensitivity reader Removal/replacement tool Retrofit adapter bracket Full line of options including: - 85 dB sounder - I:orm C relay - Isolated thermal sensor Maintains the i3 feature set including: Plug-in design Mounting base included In-line terminals Mounts to octagonal, single- gang and 4-square back b(,xes, or direct to the ceiling St:op-Drop 'N Lock TM attachment to the base Rl~movable cover and chamber Romote maintenance signaling DI'ift compensation and sn~oothing algorithms Simplified sensitivity measurement Dual color LEDs E~~ Walk loop testing @ LISTED System Sensor's i3- sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and Instant Inspection in a series of specialty conventional devices. Installation ease. Throughout the i3 series, installation is simple with its installer- friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options, and provides ample space for pre-wiring the installation. To complete the installation, the i3 detector plugs into its base with a simple Stop Drop 'N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms such as RF interference and dust accumulation. When connected to the 2W-MOD2Ioop test /maintenance module or an i3 ReadyTM panel, 2-wire i3 detectors can generate a remote maintenance signal when they are in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent per foot obscura- tion, within seconds. Instant inspection. The i3 line's red and green LEDs simplify local status indication dur- ing power-up, standby, alarm, maintenance and freeze trouble conditions. When in alarm, i3 sounder models generate an 85dB temporal tone. If connected to the RRS- MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. Additionally, the RRS-MOD synchronizes the output of all i3 sounders, to ensure a clear audible signal. Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detect- ed, and a general alarm when the thermal sensor is activated. Architect/Engineer Specifications Smoke detector shall be a System Sensor i3 Series model number , listed to Underwriters Laboratories UL 268 for Fire 'otection Signaling Systems. The detector .tall be a combination photoelectridther- mal equipped with a sounder (model 2WfA-B, 4WfA-B), a Form C relay (model 2WTR-JB), a combination sounder/relay (model 4WfAR-B) or an isolated thermaL'sounder/relay (model 4WITAR-B). The detector shall include a mounting base for mounting to 3if-inch and 4-inch octago- nal, sin~~e gang, and 4-inch square back Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized 2-wire: 8.5 V - 35 V 4-wire: 10 V . 35 V Maximum Ripple Voltage 30% of applied voltage (peak to peak) LED Modes boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre- wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5% per foot nomi- nal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power Standby Current 2-wire: 50 fJA maximum average 4-wire: 50 fJA maximum average Peak Standby Current 2-wire: 100 fJA 4-wire: n/a Maximum Alarm Current 2.wire: 130 mA limited by control panel 4-wire: 4WTA-B, 4WTR-B : 35 mA 4WTAR-B, 4WITAR-B: 50 mA up, normal standby, out of sensitivity, alarm, and freeze trouble conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. When used in con- junction with the RRS-MOD module, all i3 sounder models on a loop shall sound when one alarms, all shall be synchronized, and all sounders may be silenced from the panel. o Alarm Contact Ratings 2-wire: n/a 4-wire: 0.5 A @ 30V AC/DC Form C Contact Ratings 2A@ 30V AC/DC Power Up Sequence for LED Indication Red LED Blink every 10 seconds off Blink every 5 seconds Blink every 10 seconds Solid Duration 80 seconds Physical Specifications Operating Temperature Range 320F-100oF (OOC-37.80C) Operating Humidity Range o to 95% RH non-condensing Thermal Sensor 1350F (57'.20C) fixed Freeze Trouble 410F (50C) Ordering Information Condition I nitial LED status indication Sensitivity 2.5%/ft. nominal Input Terminals 14-22 AWG Dimensions (including base) 5.3 inches (134 mm) diameter 2.0 inches (51 mm) height Approximate Weight 7.1 oz. (200 grams) Model Thermal Wiring Alarm Current 2WTA-B Yes 2,wire 130 mA max. limited by control panel 2WTR-B Yes 2-wire 130 mA max. limited by control panel 4WTA,B Yes 4-wire 35 mA 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4,wire 50 mA 4WITAR.B Yes 4,wire 50 mA System Sensor Sales and Service Model RRS-MOD 2W-MOD2 SENS-RDR RT A 77-AB2 ) Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA,B, 4WTAR-B, and 4WITAR-B only) Mounting 3lf-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Description Reversing relay/synchronization module 2-wire loop test / maintenance module Sensitivity reader Removal/replacement tool Retrofit adapter bracket System Sensor - Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Headquarters 3825 Ohio Avenue ')t CharIE's, IL 60174 OO-SENSOR2 30/377,6495 Documents on Demand 800/736-7672 x3 www.syst.~msensor.com System Sensor - Europe Ph: 44.1403.276500 Fx: 44.1403.276501 LED Mode Power up Normal (standby) n"t of sensitivity ze trouble .m Green LED Blink every 10 seconds Blink every 5 seconds off off off System Sensor - China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor - Singapore Ph: 65.273.2230 Fx: 65.273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 .J @ 2002 System Sensor. The company reserves the right to change product specifications without notice. System Sensor - India Ph: 91.11.558.2119 Fx: 91.11.527.6815 AO~034&OOO'11/02,#g88 CONVENTIONAL DETECTION . (.- ;3.) Series Reversing Relay/ \ b Synchronization Module Model RRS-MOD Reversing relay jsynchronization module for j3 series sounder models Product Overview ~~ SYSTEM C~ SENSOR Compatible with 2- and 4-wlre i3 detec- tors equipped with a sounder Activates all i3 sounders on a loop when one alarms Synchronizes all i3 sounders on the loop for III clear alarm signal Can be used with bell/alarm, alarm relay, or NAC outputs Includes a field-selectable switch to accommodate both coded and continu- ous alarm signals Allows 13 detector silencing from the panEtl or keypad Operates on 12- and 24-volt systems lulck-connect harness and color coded Nires facilitate connections @ LISTED System Sensor's RRS-MOD reversing relay/synchronization module enhances the operation of 2- and 4- wire i3 series detectors equipped with a sounder. Installation ease. The RRS-MOD includes a Velcro :ittachment for easy installa- tion into the fire alarm control panel cabinet. A quick-connect harness and color-coded wires simplify connections. Intelligence. The RRS-MOD's design is flexible to accommodate virtually any application. The RRS-MOD is compatible with both 2- and 4-wire i3 series detectors operating over 12V and 24V systems. The module can be used with either bell/alarm, alarm relay, or NAC outputs, and its field-selectable switch accommodates both coded and continuous alarm signals. Instant inspection. To meet fire alarm requirements, the RRS-MOD activates all i3 sounders on a loop when one alarms. Additionally, the RRS-MOD synchro- nizes the output of the i3 sounders, regardless of whether the panel's alarm sig- nal is continuous or coded, to ensure a clear alarm signal. Architect/Engineer Specifications Reversing relay/synchronization module shall be a System Sensor i3 Series model number RRS-MOD, listed to Underwriters lboratories as a smoke detector accessory. de module shall allow all 2-wire and 4- wire i3 Series detectors equipped with a sounder on a loop to sound when one alarms. The module shall provide a switch to toggle between coded mode and continu- ous mode. When in coded mode, the mod- ule shall synchronize the i3 sounders on the loop to mirror the input signal. When in continuous mode, the module shall syn- chronize the i3 sounders on the loop to the ANSI S3.41 temporal coded pattern. In either coded or continuous modes, the RRS-MOD module shall permit sounders to be silenced at the panel. The RRS-MOD module shall operate between 8.5 and 35 VDC, and shall provide 18 AWG stranded, tinned conductors connected to a quick- connect harness, o Electrical Specifications Operating Voltage Nominal: Min.: Max.: Avg. Operating Current 25mA 12 1 24 V 8.5 V 35 V Physical Specifications Operating Temperature Range 320F-1310F (OOC-550C) Relay Contact Rating 2 A @ 35 VDC Operating Humidity Range 5% to 85% non-condensing Wire Connections 18 AWG stranded, tinned, 16" long Dimensions Height: 2.5 inches (63 mm) Width: 2.5 inches (63 mm) Depth: 1 inch (25 mm) UL LISTED AlARM CONTROL PANEl BElli AlARM CIRCUIT (positive signal In aJarrnstate) 2-WIRE + INITIATING DEVICE CIRCUIT AUX POWER UL LISTED ALARM CONTROL PANEL ALARM RELAY (NO Contact) 2-WIRE + IhllllATING DEVICE CIRCUIT + AUX POWER 2-Wlre System Triggered from Alarm/Bell Circuit: PURPLE T. YEll.OW ,... BROWN OUT. ORANGE IN- WHITE OUT REO PWR. BLACK PWR OPTIONAL REMOTE ANNUNCIATOR (RMOnZ) EOl ) NOTE: These diagrams represent two common wiring methods. Refer to the RRS-MOD installation manual for addi- tional wiring configurations. OPTIONAL REMOTE ANNUNCIATOR (RA400Z) SOIOI-OO 2-Wlre System Triggered from Alarm Relay Contact: YELLOW 'N. BROWN OUT. ORANGE IN- WHITE OUT- REO PWR. Model RRS-MOD Orderln,g Information BLACK PWA- OPTIONAL REMOTE ANNUNCIATOR (RA400Z) EOL OPTIONAL REMOTE ANNUNCIATOR (RA400Z) 50103-00 Description Reversing relay Isynchronization module for j3 series smoke detectors System Sensor Sales and Service System Stlnsor Headquarters 3825 Ohio Avenue <;1. Charles, IL 60174 10/SENSOR2 ,0/2:77-6495 Documents-an-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor In China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 @2002 System Sensor. The company reserves the right to change product specifications without notice. A05-035Q-000 '11/ 02 '#990 UROX.S911 - Smoke-Automatic Fire Detectors Page 1 of raI Online Certifications Directory UROX.S911 Smoke-Automatic Fire Detectors Page Bottom Questions? Smoke-Automatic Fire Detectors Guide Information SYSTElV[ SENSOR, UNINCORPORATED DIV OF HONE~LLINTERNATIONALINC 3825 OH][O AVE ST CHARLES, IL 60174 USA S911 I Control Unit Velocity Range-fpm Detector Compatibility Model Type Restriction Min Max Application 88]l I ** 0 300 ++OAP 882 p ** 0 300 ++OAP 3251 lIP ** 0 1000 OAPID(I) 2451, JTY-GD-2451 P ** 0 3000 +OAP/D(I) 2400, 2400TH(h), P ** 0 3000 OAP 2551 T(h)(T), JTY-GD-2400 2451 TH(h) P ** 0 3000 OAP/RS 2551(T),2551HR(T), P ** 0 3000 OAPID(I) 2551 TH(h), JTY-GD-ZM2551(T) 5808LST(h) P ** 0 300 OAP/RF 21 OORF ADT(h) P ** 0 300 OAP/RF 2151 p ** 0 3000 OAPID(I) http://database.u1.comlcgi-binlXYV Itemplate/LISEXT II FRAME/showpage.html?name=UROX.S911&ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 2 of @ 2251, 2251 T(h) P ** 0 4000 OAP/D(I) 2251B, 2251 TB(h) P **** ***** 0 4000 OAP , 2251 TM(h) P ** 0 4000 OAP 2251TMB(h) P **** ***** 0 4000 OAP , FfX-Pl Filtrex P ** 0 4000 OAP/D(I) SD300, SD300T(h) P ** 0 3000 OAP 2100(T), 2100S P ** 0 3000 GAP 2100TS(h) P ** 0 3000 GAP 2100AT(a,h) P * 0 300 OAP 2100TR(h) P * 0 300 OAP 2112ATL(a,h) P * 0 3000 GAP 2112/24S P * 0 3000 GAP 21 12/24TD, 2112/24TS(h) P * 0 3000 OAP 2112/24TR(h) P * 0 300 OAP 21 12/24ATR, 2112/24AT(a,h) P * 0 300 OAP 2112/24AITR(a,h,i) P * 0 300 OAP 2112/24R P * 0 300 OAP 2424A T( a,h), P * 0 3000 OAP 2424AIT( a,h,i) 2412, 2424 with or P ** 0 3000 OAP/RS without suffix TH(h) 2\V-B, 2WT-B, 4W-B, 4WT-B P ** 0 1000 OAP 4VlITAR-B (a,h), P ** 0 1000 OAP/RS 4\VTAR-B (a,h), 4\VTR-B (h), 4\VTA-B (a,h), 2VlTA-B (a,h), 2\\rTR-B (h) 1451DH I ** 0 1200 OAP 1451DHHT(et) I ** 0 1200 OAP 1400, I ** 0 1200 OAP http://database. u1.comlcgi-bin/XYV /template/LISEXT /IFRAME/showpage.html?name=UROX.S911 &ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 3 of JTY -LZ-1400 1412, 1424, I * 0 1200 OAP/RS JTY-LZ-1412, JTY-LZ-1424 1251 I * 0 500 OAP 1251B I **** ***** 0 1200 OAP , JTY-LZ-ZMI551 I ** 0 1500 OAP 1151, 1151EIS, 1451 I ** 0 500 +OAPIRS/D(I) 1100(T) I ** 0 1200 OAP 1112/24(T), I * 0 1200 OAP 1112/24B(T) 1451 I ** 0 1200 +OAPIRS/D(I) 72511SA L None 0 300 GAP DUCT DETECTORS Pressure Differential Between Sampling Tube Velocity (in of Compatible (fpm) W6x16 Detector Control Model Principle Application Max Min Max Min Unit DH500ACDC(T) I D/ST 4000 500 1.0 0.05 ** with 1551 head with 2551 head P D/ST 4000 500 1.0 0.05 ** DH500(T) I D/ST 4000 500 1.0 0.05 ** with 1551 head with 2551 head P D/ST 4000 500 1.0 0.05 ** DH400(T) I D/ST 4000 500 1.0 0.05 ** with 1451DH head with 2451 head P D/ST 4000 500 1.0 0.05 ** DH400ACDC(T) I D/ST 4000 500 1.0 0.05 * with 1451DH head I I I I I I http://database.u1.comlcgi-binlXYV /templatelLISEXT /IFRAME/showpage.html?name=UROX.S911 &ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 4 of with 2451 head P D/ST 4000 500 1.0 0.05 * DH400ACDClliT( et) I D/ST 4000 500 1.0 0.05 * with 1451DHHT head DHI00P(S), P D/ST 4000 500 1.4 0.03 ** DH200P(S), EDH200P(S) DH200RP(S), DH100LP P D/ST 4000 100 1.2 0.0015 ** EDH100LP P D/ST 4000 100 1.2 0.0015 ** EDH1 00LP470, EDHI00LPI000, DH100ACDCLP, P D/ST 4000 100 1.2 0.0015 * DHI00ACDCLPX DHI00ACDCLWP P D/ST,N4,W 4000 100 1.2 0.0015 * EDHI00ACDCLP P D/ST 4000 100 1.2 0.0015 * EDH200RP(S) DHI00ACDCP(S) P D/ST 4000 500 1.4 0.03 * DH100ACDCI(T) I D/ST 4000 500 1.4 0.03 * P270-1000I(T) I D/ST 4000 300 1.0 0.05 * with 1451DH head P270-1000P(T) P D/ST 4000 300 1.0 0.05 * with 2451 head DH200PL P D/ST 4000 100 1.4 0.03 ** DH200RPL P D/ST 4000 100 1.4 0.03 ** Base Control Unit Model No. Related Detector Compatibility Restriction B401, B401B, B401BH, 1451,2451, ** B401BR, 2451TH,J1lr-CJD-2451 B401R, DZ-B401, DZ-B401B B401, B110LP, B11ORLP, 1151, 1151EIS, 2151 ** Bl12LP, B114LP(RS), http://database.u1.comlcgi-binlXYV/template/LISEXT II FRAMEIshowpage.html?name=UROX.S911 &ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 5 of B116LP(RS), B401BH B402B(RS) 1451,2451,2451 TH, ** ITY -GD-2451 B404B(RS) 1451, 2451, 2451TH, * ITY -GD-2451 B404BT 1451,2451 * B406B(RS), 1451, 2451, 2451TH, ** B501, B501B, B501BH, 1551,2551 ** B501BHT B1l4LPBT 1151,2151 B501, B210LP, B501BH, 1251, 1251B,2251,3251, 7251, ** 3251, 7251 ** 22:51 B, 2251 TB, 2251 TMB, DZ-B501, DZ-B501B, B224BI, B224RB(RS) B501B-FTX FTX-P1 Filtrex ** B801 881 ** RMK400 1251, 1251B, 1451,2151,2251, - 2251B, 2251 TB, 2251TMB, JTY-GD-2451, JTY-LZ-1451, 2451, 5451, 5451EIS, 5551, 5551R, JtW-BD-ZM5551, ITW -BD-ZM5451, CPX-551, FDX-551, FDX-551R, SDX-551, SDX - 7 51, TC804C Series, TC804D Series, TC805C Series, TC806A Series, TC806B Series, TC807 A Series, TC808A Series, (Heat Detectors) http://database.u1.comlcgi-binlXYV/temp1ate/LISEXT II FRAME/showpage.htm1?name=UROX.S911 &ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 6 of I..- Recessed mounting base RMK400 is only to be used with bases B401, B501, and detector Models 1451, 2151, 2251, ? 5451, 5451EIS, 5551, 5551R, CPX-551, FDX-551, FDX-551R, JTY-GD-2451, SDX-551, TC804C Series, '1 ,",,,J4D Series, TC805C Series, TC806A Series, TC807A Series, TC808A Series, TC806B Series. Projected beam smoke detector, Model BEAM200S, BEAM200. For connection to Listed control units with which compatibility was determined by test. Compatible models indicated on installation wiring diagram for control unit. Suitable for use in ambient temperatures of -30 C to 55 C (-22 to 131 F) with a max distance of 18 in. below the ceiling. Models 6424, BEAMI224S, BEAMI224. For connection to any manufacturer's Listed compatible control unit. Suitable for use in ambient temperatures of -30 C to 55 C (-22 to 131 F) with a max distance of 18 in. below the ceiling. N4 - NEMA 4 rated watertight housing. (a)-Includes integral audible signal. (h)-Employs auxiliary 135 F rated heat sensor. (i)-Heat slensor is electrically isolated. (et)-Suitable for elevated temperatures up to 70 C. ('T') C'llitable for use in ambient temperatures of 0-49 C (32-120 F). (S)-Suitable for use in ambient temperatures of 0-55 C (23-131 F). (R)-Suitable for use in ambient temperatures of 0-50 C (32-122 F). RF-Employs integral RF transmitter. W - To b(: installed in moderate climates where the ambient air temperature will not fall outside the range of320F to 1310F (OOC to 550C) . +-Suitablc~ for duct application, installation inside duct, only when used with Model B404B, B404BT or B114LP base and Mode:l R TC remote test kit. ++ Model is not to be sold or distributed in the United States of America. *-For connection to any manufacturer's Listed compatible control unit. **-For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit. ***-For use with the following Listed Control panels, Models Commander 2000, Ultraguard, Caretaker 4000 with al supervision requirements in compliance with NFPA74 and DS7400X when used with keypad Model DS7447 anoli:ldio receiver 60-731 (RF434ITI, RF435ITI). When used with the Caretaker Plus or custom versions with software version 3.0 or earlier and Commander 2000 or custom versions with software version 4.0 or earlier panels, the detector http://database.ul.comlcgi-binlXYV /template/LISEXT /IFRAME/showpage.html?name=UROX.S911 &ccnshc.. 2/9/0 UROX.S911 - Smoke-Automatic Fire Detectors Page 7 of must be installed by a professional installer. ****-For connection to Listed Control Unit, Model ZXa manufactured by Morely with which compatibility was t. mined by test or a review of circuit parameters. Interconnection and compatible models are indicated on installation wiring diagram for Detectors and/or control units. *****-For connection to Listed Control Unit, Shark Series 10-056 manufactured by Fike Protection with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models are indicated on installation wiring diagram for Detectors and/or control units. Code: I-Ionization L- Laser P- Photoelectric lIP-Combination Ionization and Photoelectric OAP-Op(m Area Protection RS-Releasing Service ~ <\-Special Application D/" 1'- Duct Detector, Sampling Tubes D(I)-Duct Detector-Installation Inside Duct N/A-Not Applicable Page Top Notice of Disclaimer Questions? UL List(~d and Classified Products UL Recognized Components Products Certified for Canada This page and all contents are Copyright ~ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Fol1ow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits. the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listiings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The state:ment "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the fol1owing format: "Copyright ~ 7- . T Tnderwriters Laboratories Inc.@" http://database.u1.comlcgi-bin/XYV/templateILISEXT/IFRAME/showpage.html?name=UROX.S911 &ccnshc.. 2/9/0 Innovair~ UlIN-FIaN Ouct Smoke DetacIlan TlldTdo!rI 4-Wire Low-Flow Duct Smoke Detector Model ClHl00ACDCLP 4-Wire Photoelectric Duct Smoke Detector with Low-Flow Technology Product Overview @ I4TED The System Sensor Innovair'" DH100ACDCLP is a 4-wire photoelectric air duct smoke detector capable of sensing smoke in air velocities from 100 to 4,000 feet per minute (0.5 to 20.32 m/sec). This Innovair features Low-Flow technology that enables duct smoke detection throughout a broad range of air- flow environments. Many difficult to solve HVAC applications occur in low air- flow duct applications where reliable smoke detection is critical. Innovair with Low-Flow technology can detect smoke at air speed velocities of 100 feet per minute or greater, while continuing the same reliable performance to 4,000 feet per minute. The two available form C relay contacts provide reliable performance for the management of fans, blowers and air conditioning systems. These HVAC devices can be configured to prevent the spread of toxic smoke and fire gasses through a protected area The Innovair family is designed for simplified installation and easy mainte- nance. The modular construction allows for easy cleaning and uncomplicated field replacement of the UL recognized power and sensor boards. The patented cover missing feature insures the cover is securely tightened following routine cleaning and maintenance. The patented interconnectability feature allows mul- tiple Innovairs to communicate with each other. In the event smoke is detected, the Innovair will signal the remaining interconnected detectors to initiate their relays for smoke control. Duct smoke detectors have specific limitations. NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information about the proper application of duct smoke detectors. Archltectural/En&lneerln& Specifications The air duct smoke detector shall be a System Sensor Model DH100ACDCLP Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air veloci- ties of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 m/sec.). The unit shall be capable of controlling up to ten 1[10) air handling systems when interconnected with other detectors. The detector shall be capable of providing a trou- ble !.Ignal in the event that the front cover Is removed. It shall be capable of local testing via magnetic switch or remote testing using the SSK451 Multi-Signaling Accessory or the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or remote test station. The duct smoke detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily Installed by passing through the duct housing after the housing is mounted to the duct. The unit shall provide a spacial separation of no less than ~w (6.4 mm) and/or a physical barrier between the high and low voltage terminals. The enclosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. WIring Guide ~WER INPUTS ACCEPT ~::~~HZ.~HZ. 2201240 VIoC _ HZ. CONNECT POWER SOURCE TO APPROPRIATE TERMINAlS OF EACH DETECTOR. AUX CONTACT RATINGS lOA. 30 VDC RESISTIVE lOA. _ VIoC l00mAMlNIMUM. 5 VDC NOT INTENDED FOR CONNeCTION TO CONTROl. PIINELS. -rROUBLE CONTACT RATlNG :lOA 0 3OVDC_lIve A~RM 7 ~OON~ Ul USTED 4-W1RE CONTROL PANEL Specifications AVAIlABlE POWER INPUTS 8 10 ABC ~.~ ~!.J VAC A~RM AUXILIARY CONTACTS FOR FAN SHUTDOWN. ETC. 'ill W' ,- - - ~1J~~R~~- - -- 8 10 ABC ~.~ ~!J VAC A~RM AUXILIARY CONTACTS FOR FAN SHUTDOWN. ETC. 'ill m' ALARM AUXILIARY CONTACTS SHOWN IN STANDBY. CONTACTS TRANSFER DURING AlARM AS INDICA TED BY THE ARROWS. A~RM AUXilIARY CONTACTS SHOWN IN STANDBY. CONTACTS TRANSFER DURING AlARM AS INDICATED BY THE ARROWS. SUPERVISORY TROUBLE CONTIoCTS SUPERVISORY TROUBLE CONTACTS TROUBLE CONTACTS CLOSED IN ALAFN AND STANCB.Y I OCJNTACTSOPEN WHILE OETECTORPCB OR POWER 18 REMOVEDOR WHEN TAMPER FEATURE TIMES OUT. OPEN CONTACTS SIGNAL TROUBlE OONDlTION TO PANEL AlARM INITIATION CONTACTS AlARM INmATION CONTACTS CONTACTS SHOWN OPEN IN STANDBY. CONTACTS CLOSE IN AlARM. I ' '-_____________1 FIRST DETECTOR IN THE lOOP DH100ACDC I ' '--------______1 ~ST DETECTOR IN THE lOOP DH100ACDC 320 to 1310 F (00 to 550 C) 14~1l" (37 cm.) Length 5~'" (14 cm.) Width 23/4'. (7 cm.) Depth CONNECT POWER SOURCE TO APPROPRIATE TERMINAlS OF EACH DETECTOR. SEE SPECIFICATIONS FOR AODmONAl POWER SUPPLY INFORMAOON. FOR WIRING OF AUXILIARY DEVlCI1S, REFER TO MANUFACTURER'S INSTAl~TION INSTRUCTIONS OR CONTIoCT MANUFIoCTURER. NOTE: THE SUPERVISORY RE~Y NOW PROVIDES A 'FOIN C' CONTACT FOR CUSTOMIZED APPUCATIONS. FOR STANDARD APPUCATIONS, ONLY THE "NO" CONTACT 18 USED 1--' EO!. RESISTOR SPECIFIED BY PANEL MANUFACTURER 30/. Ibs. (1.7 kg.) 10% to 93% relative humidity non-condensing 100 to 4000 ft./min. (0.5 to 20.32 m/sec.) Electrical Ratings - DH100ACDCLP (Includes Detector) Power supply voltage: Input capacitance: R.~set voltage: R.~set time (with RTS451): R.~set time (by power down): Power up time: Alarm response time: SEmsitivity Test: 20-29 VDC 270 I1F max. 3.0 VDC min. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 24 VAC 5Q-6O-Hz 270 pF max. 2.0 VAC min. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 120 VAC 50-60 Hz N/A 10 VAC min. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 220/240 VAC 5Q-60 Hz N/A 20 VAC min. .03 to 0.3 sec. 0.6 sec. max. 34 sec. max. 2 to 17 sec. See detector label 24 VAC 50-60 Hz 2200'240 VAC 50- eo Hz Power Supply Voltage 20 . 29 VDC CURRENT REQUIREMENTS (USING NO ACCESSORIES) Max.1landby CUITeI'Il IS mA Max. alann CUITllnl 70 mA CONTACT RATINGS 35 RIA RMS 125mA RMS Alann initiation con1Bcts (SPST) 2.0A 0 30 VACIOC (0.6 power factor) Alann awdllary contacts (OPOl) lOA 030VDC lOA 0 250 VAC Ncte: Alann aulCiliary contacts must switoh l00mA nininum at 5VDC. A1ann awciIiary contacts shall not be oonnectad to inititaing circuils of cootrol panels. Uae the alarm initialon con1Bct for this purpose. Trouble conlacts (SPOT) 2.OA 0 30 VDC (resistive) 120 VAC 50- eo Hz 25 mA RMS. 35 mA RMS' 1SmAAMS" 25 mA AMS" ACCESSORY CURRENT LOADS AT 24 VOC DEVICE STANDBY TROUBlE AlARM APA45t 12.SmA Max. nla 30mA Max. PA400 OmA nla lSmA Max. RA400Z OmA n/a 10mA Max RTS4511RTS451KEY 12mA' n/a 7.SmA Max. SSK4S1 SmA Max. QrnAMax. 30mA Max .NOTE: When e unitio powered el the 120VAC or 22OI240VAC input, any combination of occeuoriea may be uoed such hi the ~ -.ory loads ar.: 60 mA or 10.. in the 8\an<l>y stale: 110 RIA or... in the oIenn ...... Important Interconnect Not.. · When using the interconnect feature. all interconnected units must be powered with the same, independent supply. · Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit 1 to terminal 12 on unit 2 and so on. Similarly, connect terminal 1 on unit 1 to terminal 1 on unit 2 and so on. DH100ACDCLP Alarm Signal 15 APA451 2 Alarm Sup. N. O. Aux.Power+ Sup. COM AU)(. Power- 1 Common NOTE: Wiring diagram shown is for DH100ACDCLP 4-wire duct smoke detec10r system equipped withou1 a control panel. NOTE: A trouble condition is indicated when the green LED is not illuminated. FIELD INSTALLED JUMPER FOR TEMPORAL PAlTERN COMMON.-@) TEMPORAL SELECTa..o@ AlARM SIGNAL I :,UPERVISORY SIGNAl 4 RESET 7 TEST 8 POWER (-) 6 POWER (+) 5 SSK451 SUPERVISORY CONTACT RESET TEST AUX. POWER (-) 9 AUX. POWER (+) 2 INTERCONNECT + I INTERCONNECT - DH100ACDCLP UNIT 1 FIELD INSTALLED JUMPER 2 INTERCONNECT + I INTERCONNECT- DHl00ACDCLP UNIT 2 DH10DACDCLP Alarm Signal I Aux. Power + I I Sup. N. O. I I Sup. COM - - -- Aux.Power- Interconnect - Interconnect + Unit 1 12 DH100ACDCLP UNIT 2 Interconnect - Interconnect + RTS451/RTS451 KEY (Red LED) Alarm ,* (Green LED) Power I I I I _I 'NOTE: For RTS451 KEY only without a Control Panel. Ordering Information DH100ACDCLP A5069 A5064 4-wlre photoelectric duct detector with low-flow technology Replacement photoelectric detector board Replacement 4-wlre power boerd ST-1.!) ST-3 ST-5 ST-10 T8D-71-00 P 48-6,5-00 SSK451 RTS4!51KEY RTS4!51 APA451 Metal sampling tube duct widths 1'-2' (0.3-0.6 10) Metal sampling tube duct widths 2'-4' (0.6-1.2 10) Metal sampling tube duct widths 4'-8' (1.2-2.4 10) Metal sampling tube duct widths 8'-12' (2.4-3.710) Replacement telescoping sempllng tube Replacement end cap for T8D-71-OO MultI-Signaling accessory Remote test station with key lock (see below) Remote test station Remote annunciator with plezo alarm M0D400R RA400Z F36-09-11 M02-04-00 P48-21-00 S08-39-01 PA400W PS24LOW P S12/ 24SLENSW Sensitivity test module Remote annunciator alarm LED (see below) Replacement air filters (two per package) Test magnet End cap for metal sampling tubes Photo replacement screen Mini-Alert sounder M Inl-A lert add-on strobe Wall-mount "SMOKE" lens Accessories System Sensor provides system flexibility with a variety of accessories, inclUlding two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct smoke detector accessories are UL listed. o ~ AIA.:..Il 1 . ~. ('S) ~ Plezo Annunciator (UL S4011) Remote Test Station with Key (UL S2522) @ @ 0000000000 ~- 0000000000 o .... 0000000000 0000000000 0... 0000000000 0000000000 ~ 0000000000 0000000000 0000000000 00000,20000 @ @ System Sensor Sales and Service Mini-Alert Sounder (UL S3593) shown with PS24LOW add- on strobe (PS12/24SLENSW smoke lens option available) ('S) ""'. ] . @ J RESET ('S) (]) I BElli (1) Remote Test Station (UL S2522) Remote Annunciator (UL S2522) - @ - S >-- 00 ~- o. M 00 o .... 00 o. 00 0""" 0 00 00 00 ~ 00 00 00 K 00 00 00 00 00 - g >-- @ Multi-Signaling Accessory (UL 268A) Multi-Signaling Accessory (UL 268A) shown with PS24LOW add-on strobe (PS12/24SLENSW smoke lens option available) Syst.m Sellllor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph:800/SENSOR2 Fx: 6aO/377-6495 Docurnents-on-Demand 800/736-7672 x3 WWw.llystemsensor.com System SellllOr Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sellllor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sellllor In China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System S-or In Slncapore Ph: 65.273.2230 Fx: 65.273.2610 C 2001) System Sensor. The company reserves the right to change product specifications without notice. System Sellllor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sellllor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sellllor - India Ph: 91.11.558.2119 Fx: 91.11.567.6815 A05-1044-000.12/00'#685 UROX2.S911 - Smoke-automatic Fire Detectors - Component Page 1 of tal Online Certifications Directory UROX2.S911 Smoke-automatic Fire Detectors - Component Page Bottom Questions? Smoke-automatic Fire Detectors - Component Guide Information SYSTEM SENSOR, UNINCORPORATED DIV OF HONEYWELL INTERNATIONAL INC 3825 OHIO AVE ST CHARLES, IL 60174 USA S911 Ionization type, Model 1551 for use with DH500 and DH500ACDC duct housings. Suitable for use inside air ducts , maximum air velocity of 1500 FPM. Photoelectric spot type, Model DOR-2400. For use with Listed doorho1der closer equipment and for connection to any manufacturer's Listed compatible control unit. Suitable for open area protection in above applications if the unit is mounted not more than 28 in. below the ceiling. The area to be protected shall not exceed 352 sq ft with a max 10ft ceiling height. Models SSDPHOTO, SSDPHOTOTB. For use in Listed doorholder closer equipment Dorma Series 140, Series 170, LCN -4040SE, -4310/441 OME Series, Sargent 2400 or 2500 Series and for connection to any manufacturer's Listed compatible control unit. Model SSDPHOTO(LOA). For use in Listed doorholder closer equipment Dorma Series 140, Series 170, LCN- 4310/4410ME Series, Sargent 2400 or 2500 Series and for connection to any manufacturer's Listed compatible control unit. Suita.ble for open area protection in above applications ifthe unit is mounted not more than 28 in. below the ceiling. The area to be protected shall not exceed 352 sq ft with a max 9 ft ceiling height. Piezo horn, Part No. A1278-01. Replaceable photoelectric sensor boards, Part No. B60-528-000. For use as a component in Listed duct detector Models DHIOOACDCP, DHIOOP. Part No. B60-580-00. For use as a component in Listed duct detector Model DH200P. ... ceable ionization sensor board, Part No. B60-529-000. For use as a component in Listed duct detector Model DHIOOACDCI. http://database.u1.comlcgi -bin/XYV /template/LISEXT /lFRAME/showpage.html?name=UR0X2.S911 &ccnsl:.. 2/9/0 UROX2.S911 - Smoke-automatic Fire Detectors - Component Page 2 of Replaceable power boards, Part No. B60-537-00. For use as a component in Listed duct detector Models DHl OOACDCP, DHI00ACDCI. I ~o. B60-541-00. For use as a component in Listed duct detector Model DHlOOP. Part No. 560-581-00. For use as a component in Listed duct detector Model DH200P. Part No. B60-582-00. For use as a component in a Listed duct detector Model DH200RP; Model DDF-351RP; Model TC806D1018. Velocity Compatibility Range (fpm) Application Type Restriction Min Max Model OAP P ** 0 300 2100ARF, 21 OOARFT, 2100ARFTITI, 2100RF , 2100RFT OAP B,P * 0 300 2300RF , 2300RFT . UAP-Upen Area Protection. Co,-", P- Photoel(~ctric. B- Battery operated. *-Intended for use with RF transmitters and control units. Suitability of these to be evaluated by test. **For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit. Marking: Company name and model designation. Page Top ----- Notice of Disclaimer Questions? UL Recognized Components -~--- Products Certified for Canada UL Listed and Classified Products This page al1id all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ .I. earance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's }'ollow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. http://datahase. ul.com/cgi-bin/XYV Itemplate/LISEXT II FRAMElshowpage.html?name=UR0X2.S911 &ccnst.. 2/9/0 UROX2,S911 - Smoke-automatic Fire Detectors - Component Page 3 of UL pennits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Infonnation, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with pennission from Underwriters Laboratories Inc." must appear ~ . 'nt to the extracted material. In addition, the reprinted material must include a copyright notice in the following fonnat: "Copyright @ :/., Jnderwriters Laboratories Inc.@" http://database.u1.comlcgi -binlXYV /template/LISEXT /lFRAME/showpage.html?name=UR0X2.S911 &ccnsl:.. 2/9/0 Rechargeable Sealed Lead-Acid Battery PS-1270 12 Volt 7.0 Amp. Hrs. Features: . Absorbent Glass Mat (AGM) technology for superior performance. . Valve regulated. spill proof construction allows safe operation in any position. . Power/volume ratio yielding unrivaled energy density. . Rugged plastic case and cover . Approved for transport by air. D.O.T., lATA, F.A.A. and C.A.B. certified. . U.L. recognized under file numberMH 20845. .<i PERFORMANCE SPECIFICATIONS Nomiraal..VQt__ ...... .... ................... ....................... ....... ................ .......... ..... ......... ....................... .............. ............... 12 volts (6 cells In..-) NOllllnal Capacity 20 hour rate (350mA to 10.50 volts) ...................................................................................................................................... 7,0 A.H. 10 hour rate (650mA to 10.50 volts) ...................................................................................................................................... 6:IA,ft, 5 hour rate (1.2A to 10.20 volts) .......................................................................................................................................... $',I)':A:H, 1 hQur rate (4.5A to 9,00 volts) ...........................................................................................................................................4.$4,..1> 15 min rate (14A to 9.00 volts) ............................................................................................................................................. 3-.'.<<;H, App~xlma" W.ight.................................................................................................................................................... 5. 70 p(JUnd$(~~~ En..rgy D.ns.lty (20 hour rat.).............................................................................................. 1.43 Watt.hourslcobic inch (87.3 W.~) $paelfteEn"rgy (20 hour rat.)................................................................................................. 14.7 Watt.hourslpoun~ (3~M wa~l I.nternai R..astance (Fully Charg.d Battery)................................................................................................... 22milliohm$ (app~ MlXbPumPi~harg. Current ( ~ 7 Min.).................................................................................................................................... 2t.~ ....xlmum Short-Duration Dlscharg. Current ( ~ 10 S.c.)...................................................................................................... 70<~ lilfminal configurations ................................................Quick disconnect tabs, "F1": 0.187" x 0.032", mate with AMP. INC. FASTGfI/, "1fJl'" Quick disconnect tabs, "F2": 0.250" x 0.032", mate with AMP. INC. FASTQN"~ Shelf Life - % of nominal capacity at 680 F (20" C) 1 Month..... ....... ....... .......... ......... ...... ...... ........ ........... ......... ........... ..... .................. ...... .... .... ....... ......... ...... .............. ....... ................ 97% 3 Months............... ......... ...... ... ..... ...... ... .... ........ ... ........ ....................... ........ ................... ........ ..... ....... ............. ... ........................... 9t% 6 Months................................................................................................................................................. ...................................... 881lI. Clp"ratlng T.mp.ratur. Rang. Charg.... .......... ................ ............... ............. .......... ....... ......... ..... ..... ................... ......... ............... ........... ........ ........ -4OF (-2QOC) to 122"F(~) D..ehal'g.... ..... ...... ...... ......... ........ ........... ........ ............ ....... ............. ......... .......... ............. ... .............. ..................... -48f HlO9C) to 14Q11F/(~' C:.................................................................................................................................................................................................... AB$']II'_ PS.1270 TECHNICAL DATA: Shelf Life and Storage Discharge Characteristics (V) 14.0 1QO l I I t u 13.. &12.0 - j ~1U 110;0 'i ~ 9.0 8.0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) . 12 J4 ..1 2 mIn.~"'" D.... nme 1.2 2.4 Life Characteristics in Stand-By Use AmblentTemperature 20'C (68'F) Discharge Time vs. Discharge Current 20 15 10 ! 100 I : I~ o ----- --- Float Ch"1Im VoItlIge 2.25 - 2.30 VlC." 5 i 2 I t 1 ~ .5 I e 30 lJ 4 3 1 2 Yea,. ~!~~... .b.,._~~;~JIi~.mlM, Life Characteristics in Cyclic Use 120 10 l100 I: I : 5 0.35 0.7 1.4 3.5 7 14 Dlacharge C'-trent (A) "lii,);:m,"~._ J 1. Dlscb'llIe Current 0.2C (Final VOltag81.7VlCell) 2. Cb.rge Cutl'8ftt: 0.1 C 3. Ambient Temperature: 2O"C to 2$"C (680F to 71"F) Physical Dimensions: in. (mm) Terminals "F1" FASTON O.1BraO.D32" ~ .....- .- III .11 1 r !-' ~ ~ i 1 1 o o 200 400 600 aoo 1000 1200 Number of Cye... .~~,,,". _ _,...".",.....~~~Qll1IIIIIllfit1! ~~. "F2" FASTON ~ O.25O"ltO.Q32" .....- -. CHARGING Cycle Applications: Limit initial current to 2.1 A. Charge until battery voltage (under charge) reaches 14.40 to 14.70 volts at 680F (20oC). Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self-discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6-9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. 1+-~5.95 (151) iF --f ~- 8&.180 Rectl.rae.bM- ""- ~~~ MODEL PS-1270 F1 12VoIt 1_0 Amp. H.. t~\ ~'\~ ",_.:;.ou :e: ___...c.......,.. --- Toleran""e are +1. 0.04 In. (+1- 1mm) and +1- 0.08 In. (+1- 2mm) for height dimenelontl. All data eubject to change without notice. _ PIlIUIRI4fI.IIJ11',. SALES & MARKETING 3106 Spring Street Redwood City, CA 94063 USA Tel: 650-364-5001 Fax: 650.366-3662 natlonal-sa/es@power-sonlc.com o CUSTOMER SERVICE 9163 Siempre Viva Road San Diego, CA 92154 USA Tel: 619-661-2030 Fax: 619-661.3648 customer-servlce@power-sonlc.com 1m3 1.5I.l 1809001-2000 FM39170 www.power-sonlc.com PRINTED IN U.SA BAZR2.MH14328 - Batteries, Standby - Component Page 1 of rail Online Certifications Directory Page Bottom BAZR2.MH14328 Batteries, Standby - Component Questions? Batteries, Standby - Component Guide Information HAWKER ENERGY PRODUCTS INC, DBA POWER SAFE MEXICO P ARQUE INDUSTRIAL PACIFICO BLVD PACIFICO 14553 22490 TLJUANA P-i\JA CALIFORNIA, MEXICO MH14328 Batteries~, sealed cell lead acid, Cat. Nos. PS470, PS605, PS612, PS630, PS632, PS650, PS665, PS670, PS670H, PS695,PS1208,PS1212,PS1220,PS1229,PS1230,PS1250,PS1252,PS1265,PS1270,PS1270H,PS1295,PS6100, PS6100H, PS6120, PS6160, PS6360, PS12120, PS12180, PS12260, PS12280, PS12330, PS12400, TC465, TC612, TC626, TC640, TC665, TC670, TC670H, TC695, TC1212, TC1219, TC1226, TC1265, TC1270, TC1270H, TC1295, TC6100, TC6100H, TC6120, TC6160, TC6360, TC12120, TC12330 with pressure release vents. Cat. Nos. PS-12300, -12500, -12550, -12600, -12750, -12800, -121000. Cat. No. PS-12120-L. Cat. Nos. PS-1242. Cat. Nos. PS-260, -445, -490, -610, -640, -682, -6200. Cat. No. PS-605. Cat. No. HR.12-280. Cat. Nos. 12GA18, 12GA27, 12GA30, 12GA33, 12GA55, 12GA75, 12GA90, 12GAX65, 12GAX100, 12GAX105, 12GAX125. ( .os. NP18-12, NP24-12, optionally followed by "B", or "FR."; Cat. No. NPX-100 followed by "B", or "R."; Cat. No;:,. 1-.fP33-12, NP55-12, NP75-12, NP100-12, optionally followed by "FR.". "12GEL" or alternate designation NP- GEL followed by capacity 30, 50, 70, or 90, optionally followed by "FR.". http://database.u1.com/cgi-bin/XYV/temp1ate/LISEXT/1FRAME/showpage.html?name=BAZR2.MH14328&c.. 2/9/0 BAZR2.MH14328 - Batteries, Standby - Component Page 2 of Marking: Company name or trademark "POWER SONIC" and battery designation on battery case or cover. Questions? .. _ .~_To~ Notice of Disclaimer UL Recognized Components Products Certified for Canada UL Listed and Classified Products This page and all contents are Copyright ~ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright ~ 2004 Underwriters Laboratories Inc.@" http://database.u1.comlcgi-binlXYV/temp1ate/LISEXT/1FRAME/showpage.html?name=BAZR2.MH14328&(.. 2/9/0 Coleman Cable - Security, Fire Alarm & Sound Wire & Cable - Type FPLR, Multi-Condu.. Page 1 of2 . COLEMANCABLE Fire Atarm Multi-Conductor Cable... Unshielded Type FPLR Conductors: Insulation: Jacket: SIGNAL: Approvals: Bare Copper Foam Polypropylene PVC with Sun Resistance, Ripcord and Sequential Footage Marking Cabled 600C 300V 16 Power limited fire alarm and communications cable for riser or non-riser applications. Fire Alarm, Smoke Detectors, Signaling, Fire Protective Circuits UL Type FPLR NEC Article 760 CUL Type CMP/FT4 California State Fire Marshal Construction: Temperature Rating: Operating Voltage: Color Code: Applications: @ c@ To view an Adobe Acrobat PDF specification, click on the PDF symbol ('II )beside the part number, CUck here to download a copy of Adobe Acrobat. ----- Nom Max Nom Part Number of Copper Insulation Jacket Nom Cap. Wt. per Number AWG Conductors Stranding Thickness Thickness O.D. fP/ft. 1000' 22 A WG Solid ~ 98204 * 22 4 Solid .006 .014 .117 20 12 11 98206 22 6 Solid .006 .019 .148 20 20 .. 98208 22 8 Solid .006 .019 .164 20 27 .. 98210 22 10 Solid .006 .019 .185 20 31 18 AWG Solid 11 98820 18 2 Solid .006 .014 .132 26 16 II 98803 18 3 Solid .006 .014 .140 25 21 .. 98804 18 4 Solid .006 .014 .154 25 27 I) 98844* 18 4 Solid .006 .014 .154 25 27 ,. , .. 98805 18 5 Solid .006 .019 .180 25 33 ". 98806 18 6 Solid .006 .019 .194 25 40 11 98808 18 8 Solid .006 .019 .210 25 52 . 98810 18 10 Solid .006 .019 .246 25 67 16 AWG Solid 11 98620 16 2 Solid .007 .014 .158 27 22 .. 98604 16 4 Solid .007 .014 .185 26 40 14 AWG Solid hlip:/ /www.colemancable.comfcatalog/Securityll0.htm 4/22/02 Coleman Cable - Security, Fire Alarm & Sound Wire & Cable - Type FPLR, Multi-Condu.. Page 2 of2 'II 98420 2 14 Solid .010 .017 .202 25 35 11 98404 4 14 Solid .010 .017 .237 25 66 12 AWG Solid 11 98200 2 12 Solid .010 .017 .236 29 53 "Not cabled [Stat!~age] L~()re()!8te] [C~~al~ID I~~....,~~()~~cts] [Technical] [t-J~....,~ [EmploYI!'.~I1~] lc;()I1~~~_':!.~l . 1586 South Lakselde Drive Waukegan.. Il 60085 Tel .1l(JD-323-9355 Fax: 847--889-1192 http://www.colemancable.com/catalog/Securityll0.htm 4/22/02 HNIR.E65391 - Power Limited Fire Alarm Cable Page 1 of BOIl Online Certifications Directory HNIR.E65391 Power Limited Fire Alarm Cable Page Bottom Questions? Power Limited Fire Alarm Cable Guide Information COLEMAN CABLE SYSTEMS INC 1586 S LAKESIDE DR W AUKEGAN, IL 60085 USA E65391 Types FPL , FPLP , FPLR , Power limited fire-protective signaling cable, Type FPLP cable also Classified for use as Fire Alann Cable in New York City. Page ToU) Notice of Disclaimer Questions? UL List{~d and Classified Products UL Recognized Components Products Certified for Canada This page and all contents are Copyright @ 2004 by Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained on UL's Website subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The stat~:ment "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright @ 2004 Underwriters Laboratories Inc.@" http://database. u1.com/cgi -binlXYV Itemplate/LISEXT II FRAME/showpage.html?name=HNIR.E65391 &ccnsJ.. 2/9/0