HomeMy WebLinkAbout08-6951
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
BUILDING PERMIT
6951
Permit Number:
Permit Type:
Class of Work:
Proposed Use:
Square Feet:
Est. Value:
Improv. Cost:
Date Issued:
Total Fees:
Amount Paid:
Date Paid:
Work Desc:
6951
FIRE SPRINKLER SYSTEM
FIRE SPRINKLER
COMMERCIAL
Address: 5217 GALL BLVD
ZEPHYRHILLS, FL.
Township: Range: Book:
Lot(s): Block: Section:
Subdivision: CITY OF ZEPHYRHILLS
Parcel Number: 11-26-21-0010..16600-0010
1,460.00
95.00
95.00
8/22/2007
INSTALL FIRE ALARM SPRINKLERS
E L FAMILY CORP IN
PO BOX 1058
ZEPHYRHILLS, FL. 33542
Phone: 813 782-2989
FIRE PERMIT FEES
15.00
F~' () o..,lu cY
2-5--D<i?
\~
T
FIRE SPRINKLER ACCEPTANCE
FIRE LINE PRESSURE TEST
FIRE DEPT. FINAL
REINSPEcnON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
LSrfcT~/
CO NT CTOR SIGNATURE PERMIT OFF I
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Fire Chief Robert Hartwig
ZEPHYRHILLS FIRE DEPARTMENT
6907 Dairy Road, Zephyrhills, FL 33542
Bus (813) 780-0041 Fax (813) 780-0044
FIRE SERVICE USER FEES ~
~:dr~ ~ ~
"~~ Billing Address: '4<'2 ,_ ~ _ _~
- ~-f fJI-p't! ~~
1f'Z--17 6A-- 'I Billing phone-NO,; " ! diP}'"!':.@7
Billing Fax No.:
Contact:
Occupancy No.:
Plan No.: e; 7 -
Business Name:
BusinessAddress:
Business Phone No.:
Business Fax No.:
Contact:
PLAN REVIEW FEES
8 Site Plan N/C
Building Plans .04 sf
Revision .06 sf
STANDPIPE SYSTEM
D Per Riser $25
SPRINKLER SYSTEMS
o 0 - 25 Heads $30
D 26 plus Heads $60
FIRE PUMP
D Per Pump $100
15: FIRE ALARM SYSTEM
o - 25 Devices $30
26 plus Devices $60
SUPPRESSION SYSTEMS
~ Wet $35
Dry $35
C02 $35
Other $35
GREASENENTlLATlON
D Hood/Ducts $35
PLANS TOTAL ~
Comments:
INSPECTION FEES
Annual N/C
1st Re-inspection $25
2nd Re-inspection $50
3rd Re-inspection $125
4th Re-inspection $250
5th Re-Inspection $500
Construction $15
Commercial $25
SPRINKLER SYSTEMS
Hydro Undergrounds $45
Hydrostatic System $45
Wet Acceptance $30
Dry Acceptance $45
Hydrant Flow $25
Hood / Booth $30
Grease Duct $15
FIRE ALARM SYSTEM
&1'" System Acceptance $50
D Recall Acceptance $50
OTHER
Fire Wall/Smoke Wall $15
LP Gas $25
Natural Gas $25
Fuel Tanks $25
Tent $15
INSPECTION TOTA~
GRAND TOTAL
PERMIT FEE
SPRINKLER SYSTEMS
o Automatic $15
FIRE PUMP
o Fire Pump $15
or-: FIRE ALARM SYSTEM
~ Detection $15
OTHER
~ LP Gas
Natural Gas
Fire Works
Fuel Tanks
$45
$45
$25
$45
FALSE ALARM FEE
1st Alarm N/C
2nd Alarm N/C
3rd Alarm N/C
4th Alarm $25
5th Alarm $50
6th Alarm $75
7th Alarm $100
8th Alarm $150
9th Alarm $200
10th Alarm $250
Non Compliance $150
"Affidavit of Service/Repair"
FALSE ALARM I
TOTAL
GREASENENTILATION
o Hood/Ducts $15
o Kitchen Suppression $15
-
PERMIT TOTAL I /$ I
."
95'
1 /s;/~ 7
~t<o/ ef~ - .rio/
Date:
Inspector:
Zephyrhills Fire Rescue
6907 Dairy Road, Zephyrhills, FL 33542
Fire Chief
Keith Williams
Bus (813) 780-0041
Fax (813) 780-0044
August 15,2007
I have reviewed and approved the plans for the fire alarm to monitor the sprinkler system
located at 5217 Gall Blvd (Hynes Aluminum). I have attached the comments for the plan
approval. If there are any questions please contact my office at 813-780-0041.
1. Install Knox box at front door on either side at a height of 6 feet. Application
provided.
Inspections Required
1. Acceptance test.
Parcel Information for: 11-26-21-0010-16600-0010 Card: 001
Page 1 of2
Search. Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked
Questions
Other Parcel Cards: 1 I .2
See Tax Collector Information - CurrenUDelinquent Taxes
The online search system is currently unavailable. Information displayed below is from a weekly archive. SOH and Taxable amounts
may not reflect current values.
ParcellD
Classification
Mailing Address
PEEPLES FAMILY CORPORATION
INC THE
PO BOX 1058
ZEPHYRHILLS, FL 335391058
Physical Address
5217 GALL BLVD
ZEPHYRHILLS33542
11-26-21-0010-16600-0010 (Card: 001 of 002)
11 - Retail Stores, One Story, All Types
Assessment (totals)
Ag Land
Land
Building
Extra Features
Total Assessment
Save Our Homes
$0
$56,000
$93,710
$4,794
$154,504
$0
Line
1
Legal Description (First 4 Lines)
TOWN OF ZEPHYRHILLS PB 1 PG
54 LOTS 1 & 2 BLOCK 166
OR 3227 PG 1011
Land Detail (Card: 001 of 002)
Description ing Units
STORE 1 FL 2 7,000.00
Taxable Value
$154,504
Cond Value
1
Acres
0.16
Additional Land Information
Tax Area Fema Code
Building Information - Year Built 1950 USE 11 - Retail Stores (One Story) (Card: 001 of 002)
Ext Wall 1 Concrete Block Stucco Ext Wall 2 None
Roof Str Flat Roof Cov Built-Up Tar and Gravel
Int Wall 1 Masonary or Minimum Int Wall 2 Plywood Panel
Flooring 1 Carpet Flooring 2 None
Fuel Gas Heat Forced Air - Not Ducted
AC Central Baths 2.00
Line
1
2
3
4
Description
UST
SPA
SDA
CAN
Sq. Feet
526
2,650
3,000
350
Extra Features (Card: 001 of 002)
cription Units
RNKFP 4,512
Sales History
Repl. Cost New
$17,672
$189,590
$252,450
$8,836
Line
1
Value
$4794
Previous Owner
Year I Month
1993 I 12
PEEPLES LOGAN C
Book/Page ~:
3227/1011 ~
Amount
$0
http://appraiser.pascogov.com/search/offline.asp?Sec= 11 &Twn=26&Rng=21 &Sbb=OO 10... 7/30/2007
....'--~
e FlreLlTEr ALarms
www.f1relite.com
GENERAL
The Fire-Lite MS-5012 is a 12-volt, five-zone fire alarm
control panel with built-in communicator. The integral com-
municator transmits event information (alarms, troubles,
supervisories, faults, etc.) to a central station. The MS-
5012 may be used in a variety of cost-effective applica-
tions, including: local fire alarm control panel (communi-
cator disabled), fire alarm control panel/communicator,
stand-alone sprinkler supervisory communicator or slave
communicator to a UL listed host fire alarm panel (requires
N.O. dry contacts to trigger five channels). Selectable trans-
mitting formats allow the MS-5012 to communicate to vir-
tually all central stations.
FEATURES
. NEW LARGER ENCLOSURE.
. Five programmable Initiating Device Circuits (zones).
Zones may be programmed for:
./ Two-wire smoke detectors (Zones 2 & 3).
./ N.O. contact devices (pulls, heats).
./ Four-wire smoke detectors.
./ Waterflow operation (Zone 3 only). . \\1.
./ Supervisory operation (Zone 4 onIY}.,~~ .~~
One Style Y (Class B) Notificatio~ A;W~\'~~ltkir- ~.
cuit (NAC). '\fl.b ~{\'O: ~e CO e: 6."000.
1.0 Amp of Notificati~~~a~c~~. ~\\..Q\\ \\~. ~~\\\~
Relay driver outputs for ~~).\t&~,,~,,'ePfJ'~~
communication failure.. 1(\Se (< \~,~ 0'> .J
. Dual-line rotary- or ~~n~<B\\Ii{!l1 'El~CT interfaces
to public telephone ~e~~~ed phone lines are not
required). .
. 12-Volt operation.
. Built-in voltmeter measures:
./ Primary AC line voltage.
./ Battery voltage.
./ Zone voltage.
. Surface Mount Technology.
. Programmable via built-in keypad (no costly external
programmers necessary).
Complies with NFPA 72 (Local, Central Station and
Remote Station [DACT only - not polarity reversal) Fire
Alarm Systems}.
Reports in several major communication formats (see
reverse).
. Fuseless, power-limited technology meets UL power-
limiting requirements.
. Smoke detector alarm verification (Zones ~& 3).
. Single-person walk test.
. Programmable Auto Silence timer and Silence Inhibit
timer.
July 12, 2004
DF-51186 . A3-1 00
MS-5012
Fire Alarm Control Panel with
built-in DACT
Section: Control/Communication
@
LISTED
S624
MEA
118-93-E
California
State Fire
Marshal
7165-0075:154
FCC
1W6USA-74525-AL-E
..--..
<IJ
'-'
CJ'.l c:::
~---t ~
--
.- c::;l..
~-s
..c:: . -
c::;l..~
~~
'- "0
0';;:
i ~\
~ 1\\
ti: 0
;;.-.U
..0-5
"Ei
~
t
~.
,
. 16-Event history buffer.
. Accurate real-time clock.
. Extensive built-in transient protection.
. Electronics and operational controls fully enclosed in a
lockable cabinet capable of housing up to 7 AH batter-
ies.
OPTIONAL IIMOTE ANNUNCIATOR
The RZA-5F is a five-zone Remote Annunciator for use
with the FireWatch 5000 Series control/communicators.
They mount to a single-gang box and offer slide-in zone
identification labels. The RZA-5F provides the following:
. Zone 1 LED (red)
. Zone 2 LED (red)
. Zone 3 LED (red)
. Zone 4 LED (red)
. Zone 5 LED (red)
. System Trouble LED
. Local Piezo Sounder
. Silence Switch
NOTE: RZA-5F requires use of AOM-12 driver module. All LEOs
are individually supervised.
Fire.Lite@ Alarms is a Honeywell company.
This document is not intended to be used for installation purposes. We try to keep our product
information up-to-date and accurate. We cannot cover all specific applications or anticipate all
requirements. All specifications are subject to change without notice.
For more information, contact Fire'Lite Alarms, One Fire-lite Place, Northford, Connecticut 06472.
Phone: (800) 627-3473, Toll-Free FAX; (877) 699-4105.
ISO 9001
.... =-:.. -. =-. =- _)I
E.NE~ I MMII'K1IIII11
QuaLln SYSTEMS
@ Flre.UTe" AlarmS
June 22, 1998
2412 and 2424
4-Wire Photoelectric Smoke Detectors
with Optional Horn & Thermal Sensors
F-545
Section: Conventional Initiating Devices
GENERAL
The System Sensor 2400 Series photoelectric detector is
specifically designed to meet the stringent performance re-
quirements of industrial and municipal fire detection and
alarm systems. The design of these detectors emphasizes
ease of installation and field maintenance.
FEATURES
· 12 or 24 VDC operation
· Unique optical sensing chamber:
- Superior signal-to-noise ratio.
- Built-in signal processing.
- 3.0% nominal sensitivity.
. Removable cover for field cleaning.
· Visible LED "blinks" in standby, latches on in alarm.
· Sealed against dirt, insects, and back pressure.
· Optional built-in 1350F (570C) thermal.
. Three-year limited warranty.
· Field metering of detector sensitivity.
· Built-in test capability.
· Low standby current.
. Twist-on mounting bracket with tamper option.
. Designed for direct surface or electrical box mounting.
· Models available with built-in 85 dBA piezoelectric horn.
· Insect-resistant screening with 0.020" (0.508 mm) open-
ings.
· Isolated or integrated operation of thermal available (cer-
tain models).
. SEMS screws for easy wiring.
· Meets performance criteria designated by UL 268.
· Built to withstand air velocities up to 3,000 feet (914.4
meters) per minute without triggering a false alarm.
APPLICATIONS
Use to contribute to life safety, fire protection, and property
conservation. Photoelectric detectors are recommended
in areas where smoldering fires are likely to ignite. In ar-
eas where small combustion particles are usually present
from forklift trucks, cooking stoves, etc., they are less likely
than ionization detectors to produce false alarms.
For further information, see System Sensor manual 156-
407-03, "Applications Manual for System Smoke Detec-
tors, "which provides detailed information on detector spac-
ing, placement, zoning, wiring, and special applications.
@ @ ,i.~ ~~:~:~I~~
LISTED ~,,~~ 7257-1209:103
S911 CS308 7257-1209:134
<8> 1~~~
OQ6A 1 .AY (2424AIT, 2424A T)
1346-88-SA
(2412B, 2412THB,
2424, 2424TH)
MEA
427-91-E Vol. III
(2412AT, 2424, 2424AIT,
2424A T, 2424TH)
.
,
CONSTRUCTION AND OPERATION
All 2400 Series photoelectric smoke detectors contain a
unique optical sensing chamber designed to sense the
presence of smoke particles produced by a wide range of
combustion sources. A custom integrated circuit incorpo-
rates signal processing to reduce false alarms and sample/
hold circuitry to provide easy field metering of sensitivity.
The optional built-in piezo horn produces an interrupted
85 dBA tone at 10 feet (3.048 m). The horn operates upon
polarity reversal of the supply voltage, when the unit senses
smoke, or when the thermal reaches its alarm point (inte-
gral thermal models only).
This document is not intended to be used for installation purposes. We try fo keep our producf
information up.to-date and accurate. We cannot cover all specific applications or anticipate all
requirements. All specifications are subject to change without notice. For more information,
contact Flre.Ute Alarms, One Fire.Lite Place, Northford, Connecticut 06472. Phone: (800) 627-
3473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299
WEB: www.firelite.com
ISO 9001
CERTIFIED
.....,--
DF-50529 - Page 1 of 3
@> Flre.L1Te" ALarms
www.firelite.com
July 14, 2004
DF-52004 F-050
BG-12 Series
Manual Fire Alarm Pull Stations
Section: Conventional Initiating Devices
GENERAL
The FireoLite Alarms BG-12 Series is a cost-effective, fea-
ture-packed, non-coded series of manual fire alarm pull
stations. It was designed to meet multiple applications
with the installer and end-user in mind. The BG-12 Series
features a variety of models including single- and dual-
action versions.
The BG-12 Series provides Fire'Lite Fire Alarm Control
Panels (FACPs), as well as other manufacturers' controls,
with a manual alarm initiating input signal. Its innovative
design, durable construction, and multiple mounting op-
tions make the BG-12 Series simple to install, maintain,
and operate.
FEATURES
. Aesthetically pleasing, highly visible design/color.
. Attractive contoured shape with light textured finish.
. Meets ADA 5 lb. maximum pUll-force.
. Meets UL 38, Standard for Manually Actuated Signaling
Boxes.
. Easily operated (single- or dual-action), yet designed to
prevent false alarms when bumped, shaken, or jarred.
. PUSH IN/PULL DOWN handle latches in the down po-
sition to clearly indicate the station has been operated.
. The word "ACTIVATED" appea rs on the top of the handle
in bright yellow, further indicating operation of the sta-
tion.
. Operation handle features white arrows showing basic
operation direction, for non-English-speaking persons.
. Braille text included in finger-hold area of operation
handle and across top of handle.
. Multiple hex- and key-lock models available.
. U.S. patent-pending hex-lock needs only a quarter-turn
to lock/unlock.
. Station can be opened for inspection and maintenance
without initiating an alarm.
. Product ID label viewable by simply opening the cover;
label is made of a durable long-life material.
. The words "NORMAL" and "ACTIVATED" are molded
into the plastic adjacent to the alarm switch (located in-
side).
. Four-position terminal strip molded into backplate.
. Terminal strip includes Phillips combination-head cap-
tive 8/32 screws for easy connection to Initiating Device
Circuit (IDC).
. Terminal screws backed-out at factory and shipped ready
to accept field wiring (up to 12 AWG/3.25 mm2).
c@us
LISTED
~
APPROVED
California
'~ State Fire
Marshal
') 7150-0075:184
MEA
67 -02-E
. Terminal numbers are molded into the backplate, elimi-
nating the need for labels.
. Switch contacts are normally open.
. Can be surface (with SB-I/O or SB-10) or semi-flush
mounted. Semi-flush mount to a standard single-gang,
double-gang, or 4" (10.16 cm) square electrical box.
. Backplate is large enough to overlap a single-gang
backbox cutout by up to 1/2" (12.7 mm).
. Optional trim ring (BG-TR).
. Spanish version (FUEGO) available (BG-12LSP).
. Designed to replace the Fire.Lite Legacy BG-1 0 Series.
. Models packaged in attractive, clear plastic (PVC),
clamshell-style, Point-of-Purchase packages. Packag-
ing includes a cutaway dust/paint cover in shape of pull
station.
Fire.Lite@ Alarms is a Honeywell company.
This document is not intended to be used for installation purposes. We try to keep
our product information up-to-date and accurate. We cannot cover all specific
applications or anticipate all requirements. All specifications are subject to
change without notice.
For more information, contact Fire'Lite Alarms, One Fire-Lite Place, Northford,
Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105.
ISO 9001
III
CERTIFIED
~I-
GIllin SYSTEMS
DF-52004. 07/14/04 - Page 1 of 2
CONSTRUCTION
. Cover, backplate and operation handle are all molded
of durable polycarbonate material.
. Cover features white lettering and trim.
. Red color matches System Sensor's popular
SpectrAlerFM horn/strobe series.
OPERATION
The BG-12 manual pull stations provide a textured finger-
hold area that includes Braille text. In addition to PUSH
IN and PULL DOWN text, there are arrows indicating how
to operate the station, provided for non-English-speaking
persons.
Pushing in and then pulling down on the handle activates
the normally-open alarm switch. Once latched in the down
position, the word "ACTIVATED" appears at the top in
bright yellow, with a portion of the handle protruding at
the bottom as a visible flag. Resetting the station is simple:
insert the key or hex (model dependent), twist one quar-
ter-turn, then open the station's front cover, causing the
spring-loaded operation handle to return to its original
position. The alarm switch can then be reset to its normal
(non-alarm) position manually (by hand) or by closing the
station's front cover, which automatically resets the switch.
SPECI FICA TIONS
Physical Specifications:
1I1111DDD111 1I11-Q') 1111-10 1111-10 111111
IIl1111l1l1 5.5 IIIIIlD 5.601 IIIIIlD 5.5 IIIITlD 6.0 IIIDJD 425 IIIDJD
(13.97 [I] ) (1423 [1]) (13.97 [I] ) (15.24 [I] ) (10.79 [1])
Ilmm: 4.1211IIDJD 4.222 IIIDJD 4.J211lIDJD 4.69 IIIDJD 425 IIIDJD
(] 0.47 [1]) (10.72 [1]) (10.47 [I] ) (11.91 Ill) (10.79 Ill)
Illllm: 139 IIIIIlD 1.439 IIIDJD 1375 IIIDJD 2.0 lIIDJD 1.75 IIIIIlD
(3.53 [1]) (3.66 [I] ) (3.49 [1]) (5.08 [1]) (4.445 [I] )
5200411.tbl
Electrical Specifications:
Switch contact ratings: gold-plated; rating 0.25 A @ 30
VAC orVDC.
ENGINEERS' & ARCHITECTS'
SPECIFICATIONS
Manual Fire Alarm Stations shall be non-code, with a key-
or hex-operated reset lock in order that they may be tested,
and so designed that after actual Emergency Operation,
they cannot be restored to normal except by use of a key or
hex. An operated station shall automatically condition it-
self so as to be visually detected as activated. Manual
stations shall be constructed of red colored LEXAN@ (or
polycarbonate equivalent) with clearly visible operating in-
structions provided on the cover. The word FIRE shall ap-
pear on the front of the stations in white letters, 1.00 inches
(25.4 mm) or larger.* Stations shall be suitable for sur-
face mounting on matching backbox SB-lO; or semi-flush
mounting on a standard single-gang, double-gang, or 4"
(10.16 cm) square electrical box, and shall be installed
within the limits defined by the Americans with Disabili-
Page 2 of 2 - DF-52004. 07/14/04
ties Act (ADA) or per national/local requirements. Manual
Stations shall be Underwriters Laboratories listed.
*NOTE: The words "FIRE/FUEGO" on the BG-12LSP shall ap-
pear on the front of the station in white letters, approximately 31
4"high.
PRODUCT LINE INFORMATION
Model
BG-125
BG-125L
BG-12
BG-12L
BG-12L5P
BG-12LOB
BG-12LO
Description
Single-action pull station with pigtail connec-
tions, hex lock.
Same as BG-12S with key lock.
Dual-action pull station with SPST N/O
switch, screw terminal connections, hex lock.
Same as BG-12 with key lock.
Same as BG-12L with English/Spanish
(FIRE/FUEGO) labeling.
Same as BG-12L with "outdoor use" listing.
Includes outdoor listed backbox, and seal-
ing gasket.
Same as BG-12L with "outdoor use" listing.
Does not include back box.
BG-12LA Same as BG-12L with auxiliary contacts.
BG-12LP5 Same as BG-12L with presignal feature.
BG-12LP5P Same as BG-12LPS with English/Spanish
(FIRE/FUEGO) labeling.
Indoor/outdoor backbox.
5B-I/0
5B-10
WP-10
WBB
17003
17007
Indoor use backbox.
Outdoor use backbox.
Outdoor use backbox.
Key lock.
Hex lock.
~J
I-(~
(mm)
5.500"
"I
--------
--------.
@) Flre.UTe" ALarms
March 30, 2000
G-250
SpectrAlert ™ Series
Horns, Strobes, and Horn/Strobes
GENERAL
Section: AudioNisual Devices
System Sensor SpectrAlert Series strobes, horns, and combina-
tion horn/strobes are UL listed for primary signaling in life safety
systems and meet ADA public mode visible signaling requirements.
SpectrAlert products can be connected to the alarm indicating cir-
cuit of a fire alarm control panel and are compatible with DC line
supervision. The SpectrAlert product line mounts to standard
backboxes using a universal mounting plate included with each unit.
An optional small footprint mounting plate fits to a single-gang box.
An accessory backbox skirt gives a cosmetic finish to a 4" x 4" x
1-1/2" or a 2" x 4" x 1-7/8" surface-mounted backbox. All strobe
and horn/strobe mounting options require only one screw attach-
ment of product to plate.
These products are designed for 12 and 24 VDC and full-wave rec-
tified unfiltered power. Full-wave rectified operation requires more
current than DC operation. For detailed current draw information,
consult the Current Draw Tables (page 2). The horn/strobe com-
bination products are factory-assembled with jumper wires for in-
tandem operation. For independent wiring of horn and strobe, re-
move jumper wires. When wired for independent operation, the
strobe will continue to run while the horn can be silenced. How-
ever, the strobe must be running for horn to operate.
Horns - The SpectrAlert Series horns and horn/strobes pro-
vide two different field-selectable/reversible tones, a high-low field-
selectable/reversible sound output setting (low selling on 24-volt
models only) and a field-selectable/reversible temp 3 pattern or
non-temporal continuous pattern. These field-selectable features
are accomplished using pins and jumpers located on the back of
each SpectrAlert horn and horn/strobe. An accessory module is
not needed to make these field selections. The horn on horn/strobe
models will operate on a coded power supply. Those horn-only
models with "He" in their part numbers will also operate on a
coded power supply. The horn and horn/strobe series includes
weatherproof models.
Strobes - The ADA-compliant SpectrAlert strobes are elec-
tronic visible warning signals that flash at 1 Hz over their operating
voltage range. These products are available in 24-volt models at
15, 15/75, 75 and 110 candela intensities and in 12-volt models at
15 and 15/75 candela intensities. The strobe series includes weath-
erproof models. SpectrAlert products feature dramatic reductions
in current requirements.
Sync-Circuit Module (MDL) - The SynceCircuit Mod-
ule is available for synchronization of strobes and horns and can
synchronize two Style Y (class B) circuits or one Style Z (class A)
circuit. The module can also generate a synchronized temp 3 tone
for System Sensor's Multi-Alert™ and PA400 horn products.' The
synchronization module allows the SpectrAlert horns on combina-
tion horn/strobes to be silenced on two-wire systems. SpectrAlert's
SynceCircuit Module can be daisy-chained for multiple zone syn-
chronization. The module does not operate on a coded power sup-
ply.
'For Multi-Alert and PA400: Strobes must be wired to a continuous
source of power (non-coded power supply).
@L"'S4011&S5512(P1215'P121575'P2415'
(ii) P241575, P2475, P24110). 55512 (81215,
8121575,82415,8241575,82475,824110).
LISTED S4011 (HC12/24).
@C...CS549(P2415A,P241575A,P2475A,P24110A,
II 82415A, 8241575A, 82475A, 824110A).
C CS548 (H12/24A, HC12/24A).
OB8A4.AY(P1215,P121575, ~ ~
P2415,P241575,P2475,P24110, ~
81215,8121575,82415,8241575,
82475,824110, H12/24). OD4A7.AV (HC12/24).
(~....~). ...
In
~.G, :'s,.~l i'..
~.
Itv~
_..=Jl
California
State Fire
Marshal
7135-1209:173 (P1215, P121575, P2415,
P241575, P2475, P24110).
7125-1209:174 (81215, 8121575,
82415,8241575,82475,824110).
7135-1209:143 (H12/24, HC12/24).
MEA ... 319-96-E (P1215, P121575,
P2415, P241575. P2475,
P24110,81215,8121575,
82415,8241575,82475,
824110, H12/24, HC12/24).
Cl
.~
c.
'"
o
~
'"
SpectrAlert™, Sync-Circult™, and Multl-Alert™ are trade-
marks of System Sensor, a division of Pillway Corporation.
This document is not intended to be used for installation purposes. We try to keep our product
information up-ta-date and accurate. We cannot cover all specific applications or anticipate all
requirements. All specifications are subject to change without notice. For more information.
contact FireoLite Alarms, One Rre-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-
3473. Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299
WEB: www.firelite.com
ISO 9001
CERTIFIED
"'_1-
DF-51609 - Page 1 of 6
FEATURES
. 24-volt strobe models: 15, 15/75, 75 and 110 candela.
· 12-volt strobe models: 15 and 15/75 candela.
. Horn models operate on 12 and 24 volts.
. Low current draw: reductions as high as 45%.
. Two field-selectable/reversible horn tones:
- 3000 Hz interrupted - electromechanical
. Field-selectable/reversible high-low dBA output on horn
(low output on 24-volt models only):
- 101 peak dBA @ 10ft. high output."
- 96 peak dBA @ 10 ft. low output."
. Field-selectable/reversible temp 3 pattern or non-temp 3 con-
tinuous pattern on horn.
. Horn/strobe can be wired either in tandem or independently.
. Weatherproof strobes, horns, and horn/strobes available.
. Horns for use with coded power supply available.
. Universal mounting plate included with each unit.
. One-screw mounting of strobe and horn/strobe to mounting
plate.
. SpectrAlert strobe and horn/strobe take up no room in the
backbox.
CURRENT DRAW TABLES
Strobe Only
. Single-gang mounting without the use of a mounting plate
(horn model only).
. Self-contained screw covers.
. Aesthetically pleasing design.
. Synchronize horn and strobe with Sync.CircuiFM module
(MDL).
. Silence horn on horn/strobe over a single pair of wires using
a Sync.Circuit module (MDL).
'Sound output varies with tone and output options selected; sound
levels based upon anechoic room measurements.
SPECIFICATIONS
Input terminals: 12 to 18 AWG (3.25 mm2 to 0.51 mm2).
Dimensions: see diagrams page 3.
Weight, horn only: 7.2 oz. (204 g).
Weight, strobe and horn/strobe: 8.8 oz. (250 g).
Mounting: see diagrams page 4.
Operating temperature: 320F to 1200F (OOC to 490C).
Operating voltage range:"" 12 V: 10.5 - 17 V. 24 V: 20 - 30
V.
.. These products should be operated within their rated voltage
range. UL does, however, test functional integrity to -20% and
+10% of manufacturer's stated ranges.
,_. ~~BlASE CURRENT (mAl PEAK CURRENT (_) IN RUSH CURRENT (':l_
~ ...,.......
lQ.5V 12V 17V 2IIV 24V - 10.sv 12V 17V 20V 24V 30V lD.5V 12V 17V 20V 24V -
ea_ DC FWR DC "'" DC "'" DC OWR DC "'" DC - DC "'" DC "'" DC 1- DC_ DC FWIl ll& FWIl DC "'" DC ..... ll& ..... DC FWR DC "'" DC .....
15 133 159 114 157 81 1211 59 120 53 80 48 7ll 480 480 450 480 420 I"", 'SO 210 ISO 270 140 1251 80108 92124 140 190 170 230 220 280 270 '70
15/75 1118 '82 142 171 1Nl 150 78 Il2 fl6 93 !l8132 - 520 - 520 480 48D 170 270 170 270 180 1271 78 104 88126 180 185 170 230 210 270 270 380
75 NA NA NA NA NA NA 145 170 123 159 102 141 NA NA NA NA NA NA 350 440 340 48D 330 48D NA NA NA NA NA NA 180 240 230 280 280 380
110 NA NA NA NA NA NA 1119 220 140 181 115 174 NA NA NA NA NA NA 480 580 450 570 .c1O Il20 NA NA NA NA NA NA 190 230 220 280 280 370
Horn Only
AVERAGE CURRENT (mAl
12UIllIIIIll ~
HIII_ T..... 10.5V 12V 17V 20V 24V -
Tone Volume /Nan DC "'n DC FWn DC AIIn DC FWI1 DC FWn DC "'"
Eleclro- High TernD 10 11 10 10 14 1 19 21 25 18 29
mech. Non 10 18 10 19 14 '" 17 29 23 34- 3lI
lDw T....... NA NA NA NA NA NA 11 12 13 13 17 1
Non NA NA NA NA NA NA 12 18 14 19 17
3000 Hz High Ternn 11 13 11 11 18 1 24 28 28 23 37
Inl8rrupt. Non 11 17 11 21 14 19 34- 27 39 35
lDw Ternn NA NA NA NA NA NA 14 14 17 15 21 1
Non NA NA NA NA NA NA 13 18 18 21 22
Horn/Strobe - 15 cd
AVERAGE CURRENT (mAl
12V_ 24V II......
1IgIlI.... T..... lD.5V 12V 17V 20V 24V 30V
T_ Valume /Nan DC ..... DC FWIl DC - DC FWR DC - DC "'"
Electro- High T"",,, 143 170 124 187 95 '''' 78 101 78 98 7S 141
mIlCh. Non 143 170 124 187 95 '''' 89 88 78100 78138
t.aw Term NA NA NA NA NA NA 70 82 88 93 63 1
Non NA NA NA NA NA NA 71 92 87 93 631
3000 Hz High Term 144 172 125 111I 97 1.. 83108 81 100 83 1
Interrupt. Non 144 173 125 186 1I!5W 78 102 80108 81 1
t.aw T"",,, NA NA NA NA NA NA 73 94 70 95 87 1
Non NA NA NA NA NA NA 72 92 89 94 881
Horn/Strobe - 15/75 cd
AVERAGE CURRENT (m.\)
12V_ 24VIIDdeJ
Hg"'.... TtlIIlp 10.sv 12V 17V 20V 24V :JOV
TaM __ /Nan DC FWR DC FWR DC - DC "'" DC .... DC "'"
Electro- High Tornn 178 193 152 181 113 ".. 85 11. 91 111 87 1
mIlCh. Nnn 178 193 152 181 113 ,.... 93 '10 89 113 88 1
Law Torno NA NA NA NA NA NA 87104 79106 751
Non NA NA NA NA NA NA 88104 80108 75 1
3000 Hz High Ternn 179 195 152 183 115 Ill. 100 118 94 118 95 1
Intentlpl. Non 179 198 152 183 11. I'" 95 114- 9..1 119 93 1.
t.aw Ternn NA NA NA NA NA NA 80106 93 106 791
Non NA NA NA NA NA NA ll9104 82 107 80 1
Page 2 of 6 - DF-51609
Horn/Strobe - 75 cd
AVERAGE CURRENT (mAl
12V....... 24V'_
Hgh/~ T...... 1D.5V 12V 17V 20V 24V 30V
TaM Valume /Nan DC own DC fWI1 DC FWIl DC FWIl DC AIIT1 DC 'Wn
Electro- High Temo NA NA NA NA NA NA 1114 191 148 187 131 187
mech. Non NA Not, NA NA NA NA 183 188 148 189 132 189
Law Temp NA Not, NA NA NA NA 158 182 138 182 119 158
Non NA NA NA NA NA NA 157 182 137 182 119 157
3000 Hz High TernD NA Not, NA NA NA NA 1119 198 151 172 139 174
Interrupt. Non NA Not, NA NA NA NA 1114 192 ISO 175 137 In
Law TemD NA NA NA NA NA NA 159 1114 140 1114 123 180
Non NA NA NA NA NA NA 158 188 139 163 124 182
Horn/Strobe - 110 cd
AVERAGE CURRENT (mA)
12V - 24V _.as
Itgh/.... Temp 1D.5V 12V 17V 2IIV 24V 30V
Tane Valume /Nan DC "'R DC "'" DC .... DC .... DC FWR DC .....
Electro- High TernD NA NA NA NA NA NA 188 241 186 209 144 200
mech. Non NA Not, NA NA NA NA 188 238 183 211 1045 202
Law TelTlp NA NA NA NA NA NA 180 282 153 204 132 189
Non NA NA NA NA NA NA 181 232 154 204 132 190
3000 Hz High TemD NA NA NA NA NA NA 193 2MJ 188 214 152 20
Intemlpt. Non NA NA NA NA NA NA 188 242 187 217 ISO 210
Law Temp NA NA NA NA NA NA 183 234 157 208 138 193
Non NA NA NA NA NA NA 182 282 158 205 137 I""
Table A-2: Regulated Load in Alarm @12VDC
Device Type # of Devices Current Total Current
(Amps) (Amps)
Main Circuit Board 1 X 0.170 = 0.170
ADM-12 (1 max.) X 0.0321 =
RZA-5F (1 max.) X 0.0301 =
4-wire Smoke Detector [ I ] X [. ?lll = c 01) ~ 9'
~
",f)..
2
Power Supervision [ ] X 0.025 =
Relay
Auxiliary Outputs:
TB3-4 Alarm (1 max.) X 0.040 =
TB3-5 Trouble (1 max.) X 0.040 =
TB3-6 Supervisory (1 max.) X 0 =
TB3-7 Comm. Fail (1 max.) X 0 =
Notification Appliances [ 1 ] X I 5" J... = I tt,' ~
.. .'
Notification Appliances [ ] X =
-
Additional Current
Draw from TB-3 (alarm =
current)
..
Sum Column for Alarm Load = .351 Amps
Note:
1. Current shown is with all LEOs illuminated.
2. Use compatible listed power supervision relay only.
15465 Rev F 5/2/97 PIN 15465:F
61
The MS-5012 provides regulated power for operating the fire alarm control panel, operating external devices, and
operating the standby battery. The power for operating external devices is limited. Use Table A-1 (standby or
nonalarm) and Table A-2 (alarm) to determine if external loading is within the capabilities of the power supply.
Table A-1: Regulated Load in Standby @12VDC
Device Type # of Devices Current Total Current
(Amps) (Amps)
Main Circuit Board 1 X 0.074 = 0.074
ADM-12 (1 max.) X 0.012 =
RZA-5F (1 max.) X 0.012 =
2-wire Detector Heads [ ] X [ ] =
4-wire Detector Heads [ l ] X [ ] = , I(JO .l. .;-.
Power Supervision 2 [ ] X 0.025 =
Relays
Auxiliary Outputs:
TB3-4 Alarm (1 max.) X 0 =
TB3-5 Trouble (1 max.) X o.04d =
TB3-6 Supervisory (1 max.) X 0 =
TB3-7 Comm. Fail (1 max.) X 0 =
Additional Current
Draw from TB-3 =
(non alarm)
Sum Column for Standby Load = . ()7 5" Amps
Note:
1. Current draw only if End-of-Line relay is installed between TB3-3 and TB3-5. Current shown is maximum
available from TB3 Terminal 5.
2. Use compatible listed power supervision relay only.
3. Refer to Device Compatibility Document for 2-wire smoke detector standby current.
60
15465 Rev F 512197 PIN 15465:F
Appendix A: Power Calculations
Use the Total Standby and Alarm Load Currents calculated in Tables A-1 and A-2 for the following battery
calculation.
Standby Load Current
(Amps)
[.'" 'S']
x
Required Standby lime in Hours (24 or 60
Hours)
[:!. ll]
=
}. S'
,
Alarm Load Current (Amps)
[.3 ... 31
x
Required Alarm Time in Hours (Le. 5 min. =
0.084 hours)
[ ]
=
6~~
,
Add Standby and Alarm Load for Required Ampere Hour Battery
=
), g~9
J. ,J 9-
7AH
Multiply by the Derating Factor of 1.2
=
Total Ampere Hours (AH) Required
=
Select a battery with a greater amp/hour rating.
Notes: * NFPA 72-1993 Central Station, Local and Proprietary Protected Premises systems require 24 hours of standby.
* NFPA 72.1993 Auxiliary and Remote Station systems require 60 hours of standby.
15465 Rev F 512197 PIN 15465: F
59
.~
~
c
~
~
\
::r:.
~ f:).
f::.r i
0 ~ \
I' Cj) ,
"
';.t
0
iN
It
'"
n:-, )-) \
\
0- f)
,... ~
""
o
1-
rt; ""1
r~
Q j
r- v
~
r
813-780-0020
City of Zephyrhills Permit Application Fax-813-780-0021
Building Department <::) r ~.... _ _ /,........
~f~~ 7e>l-")0 ~ / fYI,..
<. 'I' l)'d/t...s
Owner Phone Number
Owner Phone ~umber I 81'3.
Owner Phone N'umber L
7'PA
9 ~ "...?
Date Received
01
Owner's Name
Owner's Address I "7 ~ t; J
Fee Simple Titleholder Namel
Fee Simple Titleholder Address I
j::> t!- ~ )112 If- S
J ~
.,-
~; /.
PROPOSED USE
TYPE OF CONSTRUCTION
NEW CONSTR
INSTALL
SFR
BLOCK
6/t II
I
B
CJ
CJ
IS /1/ ~
,
PARCEL ID# I
~
JOB ADDRESS
{' ':)./)
LOT #
SUBDIVISION
(OBTAINED FROM PROPERTY TAX NOTICE)
SIGN D MOVE 0
DEMOLISH
BUILDING SIZE
IM.IJ~ 1 i' ," t.
I
I II I I I I ~ . I , , I I I , , I I I I , I I I I I , , I II I I I I I , , I I , . I III I , , I I I . . II r II I . . II , . I I , , I I II , II I , . II . I III I I , I . I I I , II 11 . I I , I III , I I I , I I , II I r I I , , 111 I 11 II I I I I , II I , 1111
~
1
D
B
o
o
I /IV<)
ADD/ALT
REPAIR
COMM
FRAME
o
[3'
o
OTHER I F I/ll-' A / flU" )o't1
STEEL D OTHER I
WORK PROPOSED
r 191/ rf It tr /f /l'9hJl17
I SQ FOOTAGE I
s: P !>1",,/t'L 1-......
,
HEIGHT I
DESCRIPTION OF WORK
VALUATION OF TOTAL CONSTRUCTION
AMP SERVICE
CJ
PROGRESS ENERGY
W.R.E.C.
VALUATION OF MECHANICAL INSTALLATION
COMPANY
REGISTERED
BUILDER
SIGNATURE
Y / N
FEE CURRENT
YfN
Address
ELECTRICIAN I
SIGNATURE .
Address I
PLUMBER I
SIGNATURE
I
License #
COMPANY
REGISTERED
Y / N
FEE CURRENT
Y/N
License #
COMPANY
REGISTERED
YfN
FEE CURRENT
Y/N
Address
MECHANICAL I
SIGNATURE
License #
COMPANY
REGISTERED
Y / N
FEE CURRENT
Y/N
Address
License #
OTHER COMPANY D t~ 0. ~ (),U (." ~ Q fl.1
~1'~~;';:;~II'1I11 ~ II ~, : 1111111111 : III ; 11111111111111111111111111111 ~:~:::L 1111111 ~,~ 11111 ~:;;; ;,~~ ~ ,7. ~~~ ~ II: I ~II~ II)
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (3) sets of Building Plans; (1) set of Energy Forms. R-Q-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
....PROPERTY SURVEY required for all NEW construction.
DI~~~i:i~~~':' , , . . , , , . . . , , , . . , , , . . . , , , . . . , , , , . . , , , , , , , , , . , . . , , . , . , . . , , , , . . . , , . , . . , , . . . , . . . , . . . . ~ ' . . , . . . . . , , . , , , . . . , , , I , , , . , , , I I , , I . , , , I , , I I I I . I I I . I ,
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (AlC upgrades over $5000)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs Sewers Service Upgrades NC Fences (PloUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proce?d with the work a~d not as authori~y !o viol~t~. cancel, alter, or
set aside any provisions of the technical codes, nor shall Issuance of a permit prevent the B~II.dlng OffiCial from the~eaft~r
requiring a correction of errors in plans, construction or violations of any codes. Every permit Issued shall become. invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authOrized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced: An extension
may be requested, in writing, from the Building Official for a period not t~ exceed nin~ty ~90) da~s and Will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the,Job IS conSidered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT (F.S. 117.03)
OWNER OR AGENT
Subscribed and sworn (or affirmed) before me this
vii ~~t' ...07 by N I... l.I ) I ~ Ir n-o ~ Jt../
o s/are personally known to me or has/have produced
as Identification.
CONTRACTOR
Subscribed and sworn to (or affirmed) before me this
by
Who Is/are personally known to me or has/have produced
as identification.
Notary Public
Notary Public
C . issl I:ll~"ti
~ JACQUELINE BOGES
~*: ':*~ Commi~-:t'3
Name of W ." ,!!!fi8 ,2010
I ,f.",,' ndedThfuTroYFajnl"",,~800-385-7019
Commission No.
Name of Notary typed. printed or stamped
PRODUCER
MURPHY & JORDAN, LLC.
32 OLD SLIP. 8TH FLOOR
NEW YORK. NY 10005
DATE {MMIDDNVj
07/26/2007
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFO~MATION
ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
HOLDER, THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
COMPANIES AFFORDING COVERAGE
,COMPANV LEXINGTON INSURANCE
I A
ili
INSURED
OEVCON SECURITY SERVICES CORP,
3880 NORTH 28TH TERRRACe
HOlL VWOOD, FlORIDA 33020
COMPANY
B
us FIRE iNSURANCE COMPANY
COMPANY
C
SCOTTSDALE INSURANCE COMPANY
COMPANY
D
COMMERCE & INDUSTRY INSURANCE COMPANY
co I
LTR,
I GENERAL LIABILITY 899098-02
A :. )("1 COMMERCiAl GENERAL LIABILITY
~ ClAIMS.... MADe 1]J OCCuR OED: $5.000 (E&O)
OWIIIERS ,. COHi'RACTOR'5 PROT
L>5. !;~-,:~g~s ~OMISSIONS
IX CONTRACTUAL
~TO"OBILE UABILITY
B l2U ANY Auro
i I ALL OWNED AUTOS
S SCHEDULEO AUTOS
HIRIiO AUTOS
NON.OWNED AUTOS
I I
n
THIS IS TO CERTIFY THAT THE POl..ICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FO~ THE POLICY PERIOD
INOICATED, NOTWITKST ANDING ANY REOUIREMI:NT, TERM OR CONDITION OF Nf't' CONTRACT OR OTHER DOCUMeNT WITH RI:SPI:CT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PER1'AIN. THE INSURANCE AFFORDED B Y THE POUCIES DESCRIBED HEREIN IS SUBJECT ro ALL THE TERMS.
EXCLUSIONS AND CONDITIONS OF SUCH ~LICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
I POUcy eF~e I PQUCY EXPIRATION I
TYPE OF INSURANce POLICY NUMBER i DATE IMMlOOIYYI DAT!! IMMIDOIYY)
GENERAl AGGJ;lEGA TE
LIMITS
2128/07
2/28/08
;$
2.000,000
1.000,000
1.000,000
1,000,000
100,000
5.000
PROOUCTS. COMPIOP "00 i S
PERSONAL & AOIIINJURV $
EACH OCCUAflEI'ICE S
FIRE DAMAGE (Anyone ~rel $
lAeoE.lCP (A.nyCII'IC~) $
1337228883
2128107
2/28/08
COMBINED 51NGI.E LIMIT
$
1,000.000
800lt V lNJUR\'
(1'..-_)
s
BODILY INJURY
(Per accident)
~--
PROPERTY ClAMAGE
GARAGE LIABILITY
ANY AUTO
~CESS UABILITY
C IX-I UMBRELLA FORM
n OTHER THAN UMBRELLA FORM
f WOltKER'S COMPENSATION AND
D I EIAPLOYEItS' UA8lI..ITY
I TME I'I'IClPRETORt
PARlNER$lEXE(;UTNE
OFFICERS-ARE:
X INCL
AUTO ONLY. eA. ACCIDENT 1$
OTHI;R THAN AUTO ONLY!
EACHA~~.N!"ls
AGGREGATE S
UMSOO20928 2f28/07 2f28/08 EACH OCCURRENCE Is
AGGREGATE Is 10,000.000
1$
WC5J11882 2128/07 2128108 X WCSTATu. FJ'" I
TORY UIOITS
El EACH ACCIDENT 1$ 1,000,000
----_.,..,._~
El. OIGEASE - I"(lLlCV LIMIT $ 1.000,000
El DISEASE - EA EMPLOYEE S .. , 1,000;000'"
EXCL
OTHER
D~~11"'T1ON OF OPEM11ONSlLOCAl1ONSIYIlHICLESlSPectAL ITEMS
::<1 '., " '. " ., ' , . ,. (;',>. "t:'
CITY OF ZEPHYRHILlS
5335 A STREET
ZEPHYRHILlS, FLORIDA 33542
$MOULD ANY 01' THE A8~ DC5CRIIIED I"OUClE5 DE CANCI!LLI!C1 DIliFOItl! THl!
EXPIRATION DAn; TlEREOF, TIE ISSUING COMPANY WILL EHOEAVOR TO ~
30 DAYS WRrlTEH NOlICl; TO 1HE CERllFlCATE HOLlIER HAlED 10 'I'HI! LI!N.
SUT FAJl.Ull:l! TO MAIl. SUCH NOncE SHlU.1.tMl"OSE NO OBuOAllON o~ 1.IA8IUl'Y
0" ANY kINO Ul'QN THI! COMPANY, ITS AGENB O~ ~EI"RESENTAT1W5,
C:\FMPROIceRTPRO".. FPli
f:
.....
()
m
z
tF.^
lI,
rl1
!~
rtu
OC
0",
~~
0",
Z'"
o
wOc")
~~c")
6 g c")
gog
m
C."'tl
(X) )::.
~cj
~~,
8li
0>",
[01
6.
00>
01<00-0
O"->m:r:
Z~<r=
-'Or
--fata-
l> ~Z ~
~8~~
~2So<
Zj.. C.5
ffi~~--f
'T1 ;,.:<
r("),c6
~ """. nT
.... ;;0
w <
01 _
o
m
(J)
o
o
;;0
-0
;;0 m
m ><
Z "
m ;0
~ m
r en
CD
,
'" W
~:I: 0
0:..:: N
~~ 0
Ml;;j~ ~
~ "
~ ??
6 (5
~.g B
o
~~ ~
88
CD
f\.)
o
o
en
,
f\.)
o
'iJO
Cl....,
co
gI
I/> _
Or
" r
~ C/)
il OJ
Z 0
m;;o
o 0
C
G)
~:r:
20
1/>0
C
Z
-i
-<
o
o 0
o
c
Ul -0
~ }>
Ul::;l
o
Z
}>
r
C
o 0
m
z
mC/)
;::m
5?< -i
r:i
m
I/>
->.
o
;;0
m
()
m
-0
-i
----,
r-co
Oc::
[;0
":::!~
OC/)
~C/)
'~
<:)
0)
~
1!8
fl"
i#::z::
"'-
Iilr-
ff;
jCO
~~
o 0
c
~Fi
o
~()
o
c
~
::<
o 8
()
'" C
~;g
(;/:::J
o
~
r-
r-
o 0
!!) :1
<. J
rn C/)
~rn
i~
[g><
::0
Fq
!!J
""0
-f
()
o
~OJ
;jc:
.:b..f!!
()~
0'"
~'"
:b~
!h;n
~
C/)
(4
;:r{
~
,3:
~)>
:"
J~
&~
f "
Jt~ ~
.. n~
'Om
(I'I'
I'm
m~
no
~..
o
;0
t
fi-
I
~
....
o
'':..
I
i
~~
177 "
~$
.)i ,."
,... CIJ
(()
~
<:>
N
<:>
<:>
'I
'"
, r
.. g'
C ::l
e:~
~U1
to ~
::l "0
o ::;.
-fo!o (l)
;!; ;:!,
=0.
~ ::l,
o -
a<g.
c: _......
<g.g'
o-s
o Cl>
c: 3
~g-
QZ,
8,Q
::l ::l"
l:l) ,
::l "
g E!!,
lOr:
Cfm
..........
. 0
0.
00'
'2.
l:l)
'<
l:l)
<
~
c:
CD
::l
..
~.
0-
3
S'
~
n
[
~
lD
::l
<
lD
5'
~
lD
DIE"I=<{f}> 1--.1
SECURITY SERVICES CORP.
,
LEITER OF AUTHORIZATION
FOR THE CITY OF ZEPHERHlLLS , FL
I, David T Phillips. licensed qualifier for Devcon Security Services Corp. do certify that the below referenced
person(s) listed on this form is/are employed by me directly or through an employee leasing arrangement; or,
is an officer of the corporation; or, partner as defined in Florida Statutes Chapter 468, and the said person(s)
is/are under my direct supervision and control and is/are authorized to purchase permits, call for inspections,
and sign on my behalf.
Printffype Name of Person Authorized
Authorized Person's Signature
p!:lt.-i""ia Clu. y '-".:>
Paul Lopezs
Dean Allen
Leo Then
Jim Wiseman
Tom Sinclare
I, the license holder, realize that I am responsible for all permits purchased, and all work done under
my license and fully responsible for compliance with aU Florida Statutes, Cod~ and Local
Ordinances.
~07
~r/~
LICENSE HOWE~ ;IGNA . - --
EF20000338
STATE LIC. NO.
If at any time the person(s) you have authorized is/are no longer emplovee(s). or officer(s). you must notifY
this department in writing of the changes and submit a new letter of authorization form which will suoersede
all previous lists.
NOTARY INFORMATION:
STATEOF:t=\oQ..\d C-c- CA.UNTYOF:~(.~
The above license holder, whose name is \ Vi' ' --t\\ .-\ \ \ .
before me and is known by ~or has produced identification (
on this ';1.2> day of \ '-r" ' 20~.
personally appeared
\-C~(,
~-~oJ)/
OTARY'S IG ATURE
d" I / 7 M 0(()07
MY CO~SSION EXPIRES / el: .
~\""I,,1. Tim Lee M :vm.
:!>~~''- ., "'"D-
$..... ~'~"a OY'"mlC~.". 'UIiNfIoN
:: . . .' =~: Seo. 17, ?JJ1I
~ .n $ AarOD ftotaIJ
3880 NORTH 28TH TERRACE' HOLLYWOOD, FLORIDA 330~,,~,,\,~ 1-800-350-5161
PHONE: 954-926-5200 . TOLL FREE: 800-~09-4911 . FAX: 954-926-1809 . E-MAIL: Info@devcon-securily.com . EF20000338