HomeMy WebLinkAbout08-7064 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813) 780-0020 FUEL TANK PERMIT 7064 Permit Number: 7064 Permit Type: FUEL TANKS Class of Work: FIRE PUMPS Proposed Use: NOT APPLICABLE Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Phone: Work Desc: FUELING FACILITY FOR CITY YARD-NO CHARGE Address: 39421 U H AV ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 12-26-21-0000-04900-0000 Name: CITY OF ZEPHYRHILLS Address: 39421 SOUTH AVE ZEPHYRHILLS, FL. 33542 ELLIS ENVIRONMENTAL GROUP LLC MECO OF NORTH FLORIDA INC ~~ tf~. 7'" /'1-- Chapter 633, Florida statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." (;j/~~ A ~~W- CONTRAcTaR SIGNATURE P IT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOnCE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 8',13-780-0020 City of Zephyrhills Permit Application Building Department Fax-813-780-0021 own~.r's Name Owner Phone Number Owner Phone Number I Owner Phone Number I Date Recleived :c:mn:: Fee Simple Titleholder Address JOB ADDRESS So0-~ ~~ ?f1 f;Ll LOT # SUBDIVISION I PARCELlD#1 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED Er' NEW CONSTR B ADD/ALT D SIGN D MOVE D DEMOLISH INSTALL REPAIR PROPOSED USE D SFR c:::B-"" COMM D OTHER TYPE OF CONSTRUCTION D BLOCK D FRAME 0 STEEL D OTHER I DESCRIPTION OF WORK I \...U \. tZ. \ If--- r 0 F- tV~ uJ -;=0-t.- L fJ~~f1S BUILDING SIZE I sa FOOTAGE I I HEIGHT I IIII.I,llr"111111111111111111111'IIIIIIIIIIIIIIIIIII'11111111111111"1111111111'1111"111'1'111"1111"1'111'1111111111'11111"111'1'111111111111 ~ELECTRICAL 1$ I 1$ I D PLUMBING 1$ I D MECHANICAL 1$ I D GAS 0 ROOFING D SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA DYES DNO IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII!IIIIIIIII11111111111111111111111111111111I11111111111111111111111111111111111111111111111111111111111 AMP SERVICE D PROGRESS ENERGY D WR.E.C. D BUILDING VALUATION OF TOTAL CONSTRUCTION VALUATION OF MECHANICAL INSTALLATION COMPANY REGISTERED BUILDER SIGNATURE Y/N FEE CURRENT Y/N ELECTRICIAN SIGNATURE , ~~ / <to ~ c.v !e-/Yl ~ CE Address License # Address License # pF~666/~t:J COMPANY REGISTERED PLUMBER SIGNATURE Y/N FEE CURRENT Y/N Address MECHANICAL I SIGNATURE Address I OTHER I SIGNATURE Address I License # 111I1111111111111111111111111111111111111111111111111111111111111111111111111I11111111111111111111111111111111111111I1111111111111111I1111111111I1 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsile, Construction Plans, Stormwater Plans wI Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsile, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. License # COMPANY REGiSTERED Y I N FEE CURRENT Y/N License # COMPANY REGISTERED YI N FEE CURRENT Y/N COMMERCIAL SIGN PERMIT Di~~~ti~~~':' . . . . , , , . , , . , . , . . , , , . . , . , . . , , , . . . . . . . . . . , . . . . , . . . , . . . . . , , . . . , , , . . . . . , , , , , . , , . . . . , , , , . . , , , . . . . . , . . , , , . , , . . . . , , , , . . . . . . . . . . . . , . , . . . . . , . . . Fill out application completely. Owner & Contractor sign back of application. notarized If over $2500, a Notice of Commencement Is required. (AlC upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plol/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I 'l ;Jht;-'W;~)j ~ NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restric,tions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with ,>'my applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor Dr contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If thE-' contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. Ifthe applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand ~hat a s.eparate perm~t. may ?e requir~d for elect~ica.1 work, plumbing, signs, wells, pools, air conditioning, gas, or other ~nstallatlons not speCifically In~luded. In the application. A permit issued shall be construed to be a license to proce?d With the work a~d not as authorlo/ !o vlol~t~, cancel, alter, or set aside any provisions of the technical codes, nor shallrssuance of a permit prevent the B~II.dlng OffICial from the~eaft~r requiring a correction of errors in plans, construction or violat~o~s o~ any codes. Everr ~ermlt Issued. shall become, invalid unless the work authorized by such permit is commenced Within SIX months of permit Issuance, or If work authOrized. by the permit is suspended or abandoned for a period of six (6) months after the time th~ work is commenced: An extension may be requested, in writing, from the Building Official for a period not t~ exceed mn~ty ~90) da~s and Will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, th~\Job IS conSidered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMM NCEMENT. FLORIDA JURAT (F.S. 117.03) n, c; _ CONTRACTOR I ~'-' ~.LL.-- OWNER OR AGENT Subscribed and swom to (or affirmed) before me this Subscribed and swo to ( r affirmed) ~Oje me' ::r, ./ by '1- 27.-;.;7 by tv fJ /T/, I c- Who is/are personally known to me or has/have produced Who is/9'rf personally known to e or has/have produced as Identification. HrC t~ as identification. Notary Public Notary Public Commission No. Name of Notary typed, printed or stamped Name of Notary , /lInce 800.385-7019 Project: The City of Zephyrhills l\\'i f< 111/ i':':."> "~ /1'):,/' . \II<::P;' l..:_/ _ _ - ,-,.,,;{ ..... -' " '.. ili "~.. .~ ~ Bid # 11-07-08 N~\)~~ ~1 ~~c;.()\1P~~.. '~~~.' / D1 tS ~~~ \o.eJ, {; (~ ~\\e~ ~\.~ 1 ~~ o~~ . . ~~ (;J ~~> General Contractor: All American Concrete 8770 Somerset Drive Largo, FL 33773 Subcontractor: MECD of North Florida, Inc. 3626 Phoenix Avenue Jacksonville, FL 32206 ",,/ -'\, ,_)J Submittals 2.01 Horizontal Dual Wall, Dual Compartment Aboveground Storage Tank 2.02 Accessories 2.02. H Gasboy ASTRA Commercial Single Product Twin 2.02.Hl OPW llAKP-0400 Automatic Nozzle 2.02.H2 OPW 7H-0400 1" Automatic Nozzle 2.02.H3 OPW 66V-1350 1" Breakaway 2.02.H4 OPW 241 TPS Hose Swivels 2.02.H5 Red Jacket Submersible Pumps 2.02.H6 OPW 10BF-5725 Emergency Shut Off Valve 2.02.1 Fuel Master 2500 Plus System 2.02.J Overfill Prevention 2.02.Jl 2.02.J2 2:02.J3 OPW 61fFStop-3050 Overfill Prevention Valve OPW 199AA V-2200 Anti-Siphon Valve Veeder Root Overfill Alarm with Acknowledgement Switch 2.02.K Leak Detection/Tank Gauge } 2.02.Kl Magnetostrictive Plus Probe Ecollom;c Firl'-/( l'!--.'isla 111 Dl's(~1l · Tested by Southwest Research Institute to SwRI 97-04 requirements for fire-resistant tank performance · Complies with NFPA 30A-2000, Code fire-resistant tank . requirements · Horizontal, vertical and rectangular designs available · Double-wall design offers integral secondary containment which can be tested for tightness on site throughout tank life · Diked design also available · Interstitial space can be monitored for leak detection · Support designs available for all seismic zones · Primary storage tank and secondary containment compatible with a wide range of fuels and chemicals · Built to nationally-recognized STI standards with strict third-party quality control inspection program · Customized compartments can be provided for cost effective multi-product storage · Capacity ranges up to 50,000 gallons · Available from a large network of STllicensed manufacturers Flameshielde Guideline Specification .Genend. 1. Provide FlameshielG- fire-resistant, doubk..waU abov~ound storage tanks. -'LatbelD11t- 1. Tanh shall bear the Steel Tank Institute Flan*hiel~ fire-resistant, double-wall idemifi~tion labeL und.tanks shall tleaJi". Southwest klstititte label forflre;.r6sistant tank.. :,~rodlt~D~on 1. TtmbBflldlbe maritifac~d in aeoordailee with Steel Tank Institute Flanl~shielde, Standard for Abo:veground Fire-Resistant Tanks. Aboveground tank primary and secondary containment (inner and oUter walls) are manufactured in accordance with Underwriters Laboratories UL 142, Standard for Steel Abo:veground Tanbfor Flammable and Combustible Liqttidi. Integral secondary. containment provides testability and aco~s for interstitial leal< deteetion monitoring. Ap.proV'ed supports are . used for aU horizontal double-wall tanks. 3. (If needed) Supports ate designed to meet choice of seismic zone 1'-4. DJ. :M:ftDufacmrer 1; ManufactUter sha.Ube a lice~~edmembercompany of the Stee'l Tank'Itl$utute 8ll'4subjet:t ~i~l Tank Institute'sQUali1:yAssurancep~. ) / Use the STI Technology Guide online for your next Flameshielde Specification! .1~4II."a., All you need in tanks! ---.,. ~ Steel ~ I n ~~~ute @ FLAIIE.HIEL~) T_"'_to~_ NFPAIOMOOO Fi.......-TIllk~ ~.a. 570 Oakwood Road Lake Zurich, IL 60047 Ph 847.438.8265 Fx 847.438.8766 Web www.steeltank.com 9/03-5M-ltem #150-50-0001 '\ I -'/ DIESEL a GASBOY Fleet Management · Commercial Dispensers . Liquid Transfer Pumps . Service and Support Gasboy-the world leader in fleet and commercial fueling Industry standard " '- Defined in more government and Industrial specs than any other supplier of fleet fueling equipment. Comprehensive product offering The broadest range of fleet management systems and commercial dispensers for most fueling applications, including gasoline, kerosene, diesel, aviation, E85/M85, and Biodiesel fuels. POS and fleet management Dispensers integrate with a complete line of Gasboy or third party fleet control systems. Atlas series offers increased durability Commercial grade construction for longer life Galvanized steel frame and painted or stainless lower panels offer superior corrosion resistance. Field proven flow-through meter Improves accuracy and performance in contaminated fuel environments. Fleet management integration TopKAr" the industry's only factory mounted integrated fleet system. CFN III PLUS- combination fleet management system and POS. Islander II card, key, or code activated island fleet manager system. Lower installation and service costs Footprints are more standardized with a single sized frame for consistent layout of low hose products. 12-month warranty standard Additional 12 months available. Service and support With over 500 Distributors and 750 Authorized Service Contractors, customers are assured of easy access to sales and service anywhere in the world. Superior graphic options Choose from factory applied paint or stainless lower doors with Tedlar@ or vinyl graphics for a uniform and longer lasting image. Quality makes the difference .- Interfaces with POS and Fleet System products. .- Factory-installed filter in convenient location. .- Improved flow-through meter increases reliability. .- Vane type pumping unit does not require special priming procedure. .- Heavy duty 13-gauge, galvanized frame and lower panels. .- Fully removable door for easier access and service with plenty of room to work. .- Removable side and top sheathing black or customer specified color, or stainless steel side and top panels. .- Brightly lit brand area and display. .- Customizable graphic options on lower door. Atlas 9100K Features, Options, Specifications Flow rates Standard, High, and Super-High flow models that deliver from 15 to 40 GPM. Master, Satellite or Combo The Master/Satellite Combo saves installation expense and extra equipment costs while also saving forecourt space. The front is master, and back is satellite for adjacent master. Meter Four~piston, positive displacement flow- through CFT meter bolsters resistance to fuel contamination with self~cleaning central chamber. Solenoid valve Standardized 1" solenoid valve that may be cleaned or replaced without breaking down pipe work. Cabinet and finish Top and sides are black or stainless steel, with lower panels painted white or optional specified color or stainless steel. POS I Fleet Management Interface Pulsers converts register revolutions to electrical pulses for conn~ction to Gasboy Fleet Management Systems or pas. Select 1:1, 10:1, or 100:1 ratios. Electrical Keytrol™ pulser and mounting kits Includes necessary pulsers, top cabinet panels, and wiring for factory~installed Gasboy Electrical Keytrol. For gallons, specify 10: 1 kits, and for liters, specify 1: 1 kits. Satellite compatible piping Provides internal piping and union for connecting to a satellite dispenser. Available on remote dispenser models only. Lighted brand area and display Illuminates product and register areas for brighter day or night fueling. Mechanical display register Veeder-Root'" mechanical registers with power reset interlock. Displays on both sides include gallons or liters to 999.9 and price per gallon or liter to 9.999. Includes --'.,non-reseuable mechanical totalizer. Pump and motor Quiet, efficient rotary vane pump with an air eliminator and self~priming built into pump casting. Pumps include an improved check valve design and field replaceable shaft seal. Continuous duty motor. Refer to table for horsepower. Pressure regulator valve Prevents product from leaking from the air elimination vent in aboveground tank installations. Factory installed filter Ten~micron filter helps ensure product purity and helps protect critical components from contamination. External filter kits Standard and high flow kits include adapter, element, and pipe fittings. Specify standard or hydrosorb element. Ticket printers Print ticket with volume dispensed. Zero start and accumulative models. Not available with light or EK options. Hose Optional 3/4" or 1" hardwall hose, variable lengths available. Automatic nozzles Restrict flow when tank is full, 3/4" or 1". Internal hose retractor Helps keep hoses out of the fueling lane. ~. ......~"".,"~~;.- ". . .. !:Ht.c<.."",,, . to~ '!RaT and run-over damage. Hand crank Ideal for regions where power outages are likely. Allows dispensing by hand at a rate of .6 liters per stroke. Mechanical reset Where a hand crank is likely to be used. Vapor recovery Complete vapor recovery kit or special nozzle boot and hanger only. Field installation required. Voltage and frequency Standard: 115VACl60 Hz. For other applications &: international: 230VACl60Hz; 230VACl50Hz; 230VACl60Hz with 380VAC motor; 230VACl50Hz with 380VAC motor. Inlet connection Standard and High: 1-112" (3.8 cm) NPT. Super High 2" (5cm) NPT. Discharge I" NPT, adjustable to 3/4" Maximum working pressure 50 PSI Dimensions Units: 53~3/4"H x 28-112" W x 18-112"0. Packaging: 67"H x 38"W x 25"0 Approvals* UL and cUL; US Weights and Measures for the resale of fuel for applications involving the contracted periodic billing of the fuel dispensed (cardlocks); MC Certificate of Approval for Canada Weights and Measures; and NYCFD. *Pending or in process as of January 10, 2005. Notices Performance flow rates Flow rates shown are maximum test rates. Actual delivery rates will vary depending upon the installation conditions, product dispensed, added accessories and size of submersible pump. Tested and calibrated for accuracy at any speed or pressure. Safety Warning Failure to follow proper installation instructions may result in property damage, personal injury, or loss of life. Gasboy products must be installed by a qualified installer and used in conformance with all building, fire, and environmental codes and other safety requirements applicable to their installation and use, including, but not limited to, NFPA 30, NFPA 30A, and NFPA 70. This product is only part of a fuel dispensing system. Additional accessories or safety devices may be necessary to meet the applicable codes. Gasboy dispensers shall not be used for the direct fueling of aircraft without filters, separators, and other equipment necessary to ensure product purity. ATLAS 9200 SERIES COMMERCIAL SATELLITE DISPENSERS '>;'lf~~~lIiiiJ,,_,"-,-"-,- ,"~J",,~~J~~~~~~:~ _ 0" j . /" " High Flow (works with 9152K, 9153K, 9852KX, or 9853AX models) Satellite dispensers May be paired with standard or high-speed remote dispensers equipped with the satellite piping option. a GASBOV @2005 Gasboy . 7300 West Friendly Ave. I PO Box 22087 Greensboro NC . 27420-2087 USA Telephone: 1 8004445579. Fax: 336 547 5920 . www.gasboy:com . saleS@gasboy.com P-7054 Atlas 9100K Series 01055 Printed in USA IMPORTANT: OPW products should be used in compliance with applicable federal, state, provincial, and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ Il;:....r_ , 11A Automatic Nozzles (11A, 11AP) OPW 11A@ Series OPW 11A@ Series nozzles are designed with today's consumer in mind. Small, trim, lightweight, easy and convenient to use, the OPW 11 A@ is a rugged performer that offers long life and reliable service. Table of Contents: 1. Features & Benefits -})rdering Specs 3. Replacement Parts 4. Flow Rate Charts 5. Instruction Sheets 6. How to Use Nozzle Guide 7. Troubleshoot Nozzle 8. Notes & Warnings Features & Benefits · Two-piece spout - the OPW spout offers the highest flow rates in the industry. Replacement Kits available from OPW. · "Accu-Stop@" flow control - allows your customers to top off their tanks to the exact amount they want...easy to stop gasoline flow precisely. · Low-profile aluminum body - light-weight easier to handle, provides an attractive, image- enhancing appearance. · Unique Hand Insulators- OPW offers both a full hand insulator and a unique two-piece option. Protects both nozzle and vehicle, and insulates users' hand. · Hold open rack is available for full service applications - the one-hand control means easy setting to flow rate for customer convenience. Duratuff@ lever and lever guard - for additional durability to protect against rough handling. · Blocker on lever guard - to help prevent the nozzle from being jammed into open position with a foreign object. · Listed by Underwriters Laboratories, Inc. - for gasoline, 15% ethanol/methanol gasoline blends. UL and ULC Listed. Visit our web site at: www.opw-fc.com for specific listings. · Low reliable shut-off - specially designed to ensure proper shut-off as low as 3 gallons per minute · Exclusive two-stage lever assembly - provides a positive shut-off, even if held in wide-open position by user. · FlowLock™ - designed to shut-off automatically when the spout is tipped up, limiting spillage. · Design Working Pressure- OPW products are designed to work at 50 PSI (3.45 bar) maximum pressure. Materials """'Py: aluminum '-ever & Lever Guard: DuratufflB> Packing: Graphite with Teflon@ Disc: Viton@ Spout: aluminum Inlet Size: 3/4" NPT Weight: 2.73 Ibs. each, 43.1 Ibs/case of 15 1.25 kg. each, 19.9 kgJcase of 15 UL Listed @ .JLC Listed @ Available Colors Black, Blue, Bright Red, Gold, Green, Red, Silver, Yellow Ordering Specifications Green 11AP-0100 11A-0100 See PNET 2006 Silver 11 AP-0200 11 A-0200 11A-0300 " " ~ed 11AP-0300 ntl ~h' ~A'P..;f)400 'c" ~" :..;-:,.". . ....,.",..,. -,.' . .c. . 11 A-0400 "" '.fue11'AP-:0500 Yellow 11AP-0900 11A-0500 11 A-0900 ntl " " 8tight Red 11AP-0301 Gold 11AP-0750 11A-0301 11A-0750 n." " " Sare 11AP-0009 11 AKP- 0009 11A-0009 11AK- 0009 "" Green 11AP-0102 l1A-0102 See PNET 2006 ""'~d 11 AP-0302 11 A-0302 " " Black Blue 11Ap..04'62 11 AP-0502 111\..0412 11 A-0502 rin " " Notes For complete ordering description, use both the product number and the 4-digit code number shown above. Example, OPW 11 AP-0400 (black hand insulator, unleaded spout, with hold-open rack and trigger) Notes: 1) Unless specified, nozzles will be provided with black hand insulators. 2) OPW may add or delete colors without notice. "') Actual colors may vary slightlyfrom production run to production run. 4) For custom colors, price quotation and lead time, contact OPW. 5) For ordering specifications not listed in this catalog, contact OPW Customer Service at 1-800-422- 2525 or visit our web site at: www.opw-fc.com. Replacement Parts Two-Piece 5BI-2110 Spout Kit 15/16" 24 7" 178 .47 .22 11A- Leaded 21. r 11AP.. Unleaded 11A111AP Hold-Open 18KVA-1000 Kit (36 qty.) 2 position w/rivets .' ; 7'\,." ';;la~. .' . 1~~;",vpen 1:o~..31. Kit 11A111AP Bushing 28S-0350 3/4" M x 1" F (NPT) Step-Up 11A111AP Hand' JAstillator 1:1iN11 AP Spout Kits OPW 511 Leaded. 1118.8.t Kera.8.8 OPW 51P1 U.Ie.tIed ( Flow Rate Charts 25 2.S ~ 2.0 ;;20 ~ ~ ~ 15 tL t.S i 0 Q ~ 10 I 1.0 ; 5 ::) i .5 A. . t ---L 0 .t . t2 16 0 20 40 60 80 FLOW RAlEoOPM (GASOLINE) ROW AATU....tN.IGASOUNe} NOZZLE INSTRUCTION SHEETS Instruction Sheet - English/French Cony InstH15889PAF.pdf Instruction Sheet - English/Spanish H15889PAE.pdf ************************************************** SPOUT REPLACEMENT Two-Piece Spout Kit H08333PA.pdf 11A1118 Spout Replacement i 11A 118 Spout Repl.PDF ************************************************** HAND INSULATOR REPLACEMENT One-Piece Hand Insulator Kit H10652PApdf Two-Piece Hand Insulator Kit H_11337 _PAPDF ************************************************** RACK REPLACEMENT _uJ8KVA H_13156_M.PDF 18KR H10150PA.pdf ************************************************* RACK REMOVAL 11A Full Service Warning For Rack Removal H_1 01 01_PA.PDF ************************************************** How To Guide - English Version HowH15893PAE.pdf How To Guide - French Version H15893PAF.pdf How To Guide - Spanish Version H15893PAS.pdf 10/11/2007 10:50 19043532647 MEeD PAGE 01 r'.-"~ \ ..t'; Facsimile To: Ct +) ~ 1e,l~rk;f Ij Company: @Fax: 'b~)- 1~. COLA From: Tony Richardson Date: I ()..; r{,a1 Re: ,." :',,' ""..,,, ..~..,,,;'.; ,Pages: .' :':::'::~I:::-:. .j' ~,:,':':<'i' I....~:..~::>-f. The original of thi~ docume~~!,,~ .~'_~~~:~!: i:~, ~~:j" . . . ( ) Regular Mail ( ~c;~~S:rnl~~~H:-~~~~~:~I::,!f:;,~::rllS is the only form of delivery ~Ul ~ > tlt {t~ ^'(. "'a f:J~~~; ~ )~~w:1!;!:iir!t~. ~ re,i >"" fle. ~ /k (-, ~ - ;";:~~~~f,1~i~~~~~J~~1~ Qb<~ cJ.l k ;t -l4u. i)~$~i~j't~\, ,", t'" ~ . :~ '~;:. ~?~ . :.:' :? ":;. J ' including cover 11J\ - 1J.f 3626 Phoenix Avenue Jacksonville FL 32206 [904] 354-8789 Fax: [904] 353-2847 www.MECOAtlanta.com 10/11/2007 10:50 19043532647 MEGD PAGE 02 AC08P. CERTIFICATE OF LIABILITY INSURANCE FAX (770)447~83S3 Agency I D^ TE (MMIDDIVVVVI 10/09/2007 THIS CERTIFICATE IS ISSUl!D AS A MATTER OF INFORMATION ONLY AND CONFERS 11IO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ^LTER ,!!:!.~.g~~~~E~DED BVTHE POLICIES BELOW, ili!iilrl~~'Reco 'oniirth''FfoHdft, 3~26 Phoenix Ave. JDr;ks"nvill e, Fl. 32206 Inc. INSURERS AFFORDING COVERAGE NAIC , . iNS\;;~l~ j{-;- Mi ii=Con'i:i nent-- C8sua 1 ty '~c~any .... ..-----,... _... ~ .__u ;;"~~lli~i'R'ji-Na'ti onai"Trust-Insurafice Co. ....'... ~-..._---. --- ~..~,..,. ,......-........".." .....,.. .-,_. .-.....--....--...,...,., ''''SLJlt1,RC American Alternative Ins Corp ~~..'" .-. ,..--,-.--.--."....-,. .~.,..~...".__.__._- --.-...--....., ,. ~~I~.~II~.?~. _~~!=~...~_'!~. '!.'::'~~~~..~!'2!:'.~... _____ .__> __._. _.._..___. INsunl R f COVERA~~$ TJ~~ POLICIes Of IN~URANCE L1S"rEO BEI,OW HAVE BEeN ISSUED TO THE lNSUAlol) NAMED ABOVE fOR THE POLICY PE~100 It>lDICATED, NOTWITHSTANDING ANY REOUIREMENt, rF.RM OR CONDITION OF ANY CONTRACT OR OTHeR tJOCUMI;f'H WITH RESPfCT TO WHICH THIS CERTlfICATF. MAY BF. ISSUED OR M^Y f"Ef{ "'\IN, 1'H'= INSllMNCE AFFORDED BY THE POLICIES DESCRIBED HElU:lN IS SUBJECT TO ALL 'THE TERMS. EXCLUSION!; AND CONOITIONS OF SUC',H POl ICII~S AGGRE(~ATF t IMIT~ ~HOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS iNsii 1l~.J - ".--, '~;;".' 0' r' r'N;;URhNC" .~.. .... . ., --I'tlI.I~-Y M::'~:;"-R -- r-poTrCY-EiFEcTiiie CPOLICY iii'iiiMlimi -- --- - -".P ..." ",- _n_._... -,~, -,~..~-, ~TR. tl~rn .__.__..',.'~.......~.._,_._':... .L ",u"u", ....D1\1EJMMmQ/rfJ... LIMITS G!:NnRM UMIJ IT\' 04<iL679248 06/30/2007 06/30/2008 r,M:H OCCURRFNcr $ 1,000 I 00.9 "Xl r;OMloIFRC:'hl (lHJr.lllIl 11.~","OD L INSURED IF REQUIRED IlliMAtihl'o RC,Nffi5"'" "," '.h.... '100 :000 . _ n __:.I ~I lllfo\~ MAIlr L~I onC:\1Il BY WRITTEN CONTRACT.~3~;~~;.;;:~:;~~ i: . .___.!.~~I~dejj X ~~l1l1tion '~in_~n.._ $1,OOO,OOO/Z,OOO,OOO 06/30/Z007 06(3012008 ~~~~V~,~~~~._ _:.,._!.,~.OJl.IQQf , , . .___. ._. .. __ ___ WAIVER at SIJBROGATION ~~RI\l IIG(lR~Gl\lr: _,_,,_ ~_._b..<<1~,.9~~ '~:'l~t. M;~:~r;~Jl F ""111 ^~rl:'I'F.1S rEn INCLUDED ~.I,l~~.!:.~~.: E~Gr, _ ..!..,.--L OOo..'..~,o.(J ,_...,. .._ "_'H~:~}~f.i.,_[. toe ' , _.' _ hUTOMOlllllHlllnllm CA 0001716 4 06/30/Z007 06/l0/2008 COMnlNEO SrNGI.F.I.IM'" IE~_"",",1 ^ X IIN\" III l'tn 1\1.1 OWNrtl MI' n~: _...,_,.J-.'-~_! g,~~ B "r;Ilf.l)IJlEf)lIllr()~ X IIIRr,1) Au"'m: X NON,~WN1:lllll" oS 1l00fl,Y INJtlHY (r~r ~~Int\n) BOOll Y INJURy Irn'MMNlIJ f'I'lON. InY "^,MGI! (fln, necldonl) ChRhAI! lI^",llTY .__...1 ANY ~:~) ~Xct!SS/UMnllF.I.1 A I,IM"IITY ~X,I or.c:\.'n r"j,:'IIIMl-:MAI,r. ~ .- ---.-..... 60A2UB0002680-00 06/30/2007 06j30/Z008 '. ~~!"~~~_!..._.._w._... H' "^Me s --~ .-............-. ... .~....I.I... .._~_ AGG $ "ACH OCCIIRRr:NCl' S 4,000,000 ^;:;GRt-G^;~'" '...--.....-s-....... 4:00(r;OO~ _....___..... .._......,...u._... ... ,,,.., ,,_.., ..,., ... S .., --....--.....,-,...- -.-.--....--.--, S -.- OTHI1R mllN hl1TO ONLY c 'J Or;OlJc:rllll,r, t-- - ...:'X .I\E1ENTrON_ ..-.!...,~.~!.oJ(] WORKm9 CnM"F.N!IJl'nON I\N(I QMrLOYI'Il!' 1,,'II"flJTY D IINY PR\lr!'tll;,10rlIrIlRTNfRIr:.Xr CI JTIVr. (lrr-'Cr-Rn.Ir;Mnl':r~ 1:~r.llJnffl' m~lt'w~Vt~rO~s hnt"", -'"O"I~1I ~._....._..-...~ B ~qu'''llIP.nt Rented from pthers 010WC07A56Sg9 06/30/2007 06/30/2008 $ }. "b~ijirrPlNsC.J~~W: , ._.._._.._____...~. H EliCH /lCI:IU(;N'T $ 1 , Q.OO , ~~Q (~I:: 'o;seiiSF.: ':~';;~MPLo';;riii '$"" ,. . 1;.000 ~oog 7'~;ISr;;;:~;~~~.~;,;. s"'---'1';'oo'O;ooo $ 200.000 $ 1,000 deductible CPP0002662630 06/3017.007 06/30/2008 OE:SCRI~l1('1N Of /)PERI\11ONr.1 L n~ noNS / vtrH!CI,F.5/UClUSlONS IIDOl!IlIlY IiNIlORSEMF.NT / ~p"'Cll\l PROVISIONS ~'.. ~lEIAAT,e.H9.1..Q.e City of Zephyrhills Attn= Ru11d1ng Dept. ~335 8th St. Zephyrhi11s. FL 33S42 C LAlO SHOULD ANY OF TWE /laDVIl DESCR'''F.D rouelEI DE CIINCE~lF.D llEFDRE TWE CXPlRIITION DIITI! THEREOf'. TUl! ISSlJINO INSURF.II WLl ENDfIIVOIl TO ""/IlL _~.L DhVS WRITTEN NOTICE TO TIlE CF.IIT1I'1CIlTe HOI.OEII NIIMED TO Tile Llln, I1ur FIIJlUIU: TO "'II". 3UCH N(1tlr:r.. $liAl,I, IMI>O!lE NO OBl.'GJI"'ON OR I,'MII,IN ITS AGeNTS OR 11F.l'~I;SENTI\T1VQS. ACORD 2S {?0011l)1l) r:AX: (813) 780-0021 @ACORDCORPORATION 1908 10/11/2007 10:50 19043532647 MEGD PAGE 03 2007..2008 BUSINESS TAX RECEIPT CITY OF JACKSONVILLE/DUVAL COUNTY MIKE HOGAN, TAX COLLECTOR 231 E FORSYTH STREET ROOM 130 JACKSONVll.lE, FL 32202-3370 PHONE: (904) 630.2080 FAX; (904) 630-1432 WEBSITE: www.Goj.netltc Note - A penalty is imposed for failure to keep this receipt exhibited conspicuously at your establishment of place of business. This receipt is furnished pursuance of chapter 770-772 City ordinance codes. RICHARDSON, ANTHONY JAMES MECO OF NORTH FLORIDA, INC. 1800 CR 209B GREENCOVESPRINGS, FL 32043..9446 ACCOUNT NUMBER: LOCATION ADDRESS: 1374810000 3626 PHOENIX AV JACKSONVILLE FL 32206-2357 DESCRIPTION: QUALIFYING AGENT, CONTRACTORS COUNTY RECEIPT DESC: MUNICIPAL RECEIPT OESC: QUALIFYING AGENT, CONTRACTORS MC 772.325 COUNTY TAX: MUNICIPAL TAX: TOTAL TAX PAID: 0.00 100.00 100.00 VALID FROM September 1,2007 TO September 30,2008 ***A TTENTION*** THIS RECEIPT IS FOR BUSINESS TAX RECEIPT ONLY. CERTAIN BUSINESS MAY REQUIRE ADDITIONAL STATE LICENSING. This is a business tax receipt only. It does not permit the receiptholder to violate any existing regulatory or zoning laws of the County or City. Nor does it exempt the receiptholder from any other license or permit required by law. This is not a certification of the licensee's qualifications. /7fk ~J TAX COLLECTOR THIS BECOMES A RECEIPT AFTER VALIDATION. PAID-423104.0004-0004 M01 09/24/2007 100.00 OCT-09-2007 14:07 COMMERCIAL INSURACE 770 447 8353 P . 01/01 ACORQ.. CERTIFICATE OF LIABILITY INSURANCE I U"II: \MM/UUI1 Tf 'J 10/09/2007 PRODUCER (770)447-6547 FAX (770)447-8353 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION Commercial Insurance Agency ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR POB 2647 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Norcross, GA 30091 INSURERS AFFORDING COVERAGE NAIC# INSURED Meco of North Florida, Inc. INSURER "- Mid-Continent Casualty Company 3626 Phoenix Ave. INSURER B National Trust Insurance Co. Jacksonville, FL 32206 INSURER c: American Alternative Ins Corp INSURER D: FCCI Insurance Group INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, I~ ~~~~ TYPE Of INSURANCE POLICY NUMBER POlICY EFFECTlVE POLICY EXPlRA llON LIMITS GENERAL LIABILITY 04GL679248 06/30/2007 06/30/2008 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABiM)I) L INSURED IF REQUIRED ~~~g,~!O RENTED $ 100,000 1 CLAIMS MADE [!] OCCUR BY WRITTEN CONTRACT MED EXP (Anyone per50n) $ excluded A ~ Pollution Liab $1,000,000/2,000,000 06/10/2007 06/30/2008 PERSONAL & ADV INJURY $ 1,000,000 WAIVER OF SUBROGATION GENERAL AGGREGATE $ 2,000,000 - INCLUDED 2,000,000 GEN'l AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ "I POLICY IX] ~r~T n LOC AUTOMOBILE UABlLITY CA 0001716 4 06/30/2007 06/30/2008 COMBINED SINGLE LIMIT X ANY AUTO (Ea .cciclenl) $ l,OOO.OO(] - ALL OWNEO AUTOS BODilY INJURY - $ SCHEDULED AUTOS (Per person) B - ...!.. HIRED AUTOS BOOll Y INJURY $ X NON-OWNED AUTOS (Per .CCldenl) - -- PROPERTY DAMAGE $ (~er accldenl) GARAGE UABILITY AUTO ONLY. EA ACCIDENT S R ANY AuTO OTHER THAN EA ACC $ AUTO ONLY AGG S EXCESS/UMBRELLA UA81LITY 60A2UBOO02680-00 06/30/2007 06/30/2008 EACH OCCURRENCE $ 4,000,000 !JOCCUR 0 CLAIMS MADE AGGREGATE S 4.000,000 C $ ~ DEDUCTIBLE $ X RETENTION $ 10,000 $ WORKERS COMPENSATION AND 010WC07A56599 06/30/2007 06/30/2008 X I WC STATU- T ID.!,tl- EMPLOYERS' LIABILITY E,l. EACH ACCIDENT S 1,000,000 D ANY PROPRIETORlPARTNERlEXECUTlVE OFFICER/MEMBER EXCLUDED? EL. DISEASE - EA EMPLOYEE $ 1,000,000 If yes. describe under E.L. DISEASE - POLICY LIMIT $ 1,000,000 SPECIAL PROVISIONS below OTH~R CPPOO02662630 06/30/2007 06/30/2008 S 200,000 qUlpment Rented from B :>thers S 1,000 deductible DESCRIPTION OF OPERA llONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PROVISIONS SHOULD ~Y OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF. THE ISSUING INSURER WILL ENDEAVOR TO MAIL -.!L DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAil SUCH NOTICE SHALL IMPOSE NO OBLlGA nON OR LIABILITY ER,ITS AGENTS OR REPRESENTATlVES. City of Zephyrhills Attn: Building Dept. 5335 8th St. Zephyrhills, FL 33542 @ACORDCORPORATlON 1988 ACORD 25 (2001108) FAX: (813)780-0021 TOTAL P.Ol ~t ""--- .. '1 . "l 2007-08 ALALUlJA LUlJNTY LUl;AL IJlJSIN~SS TAX K.E~E,IPT ACCOUNT NO. MUST BE DISPLAYED IN A CONSPICUOUS PLACE 3317 RECEIPT EXPIRES 09/30/08 23321 00003513 mSINESS TYPE 233210 CONTRACTORlSUB-GONTRACTOR Tax Amount 131.25 :lUSINESS \DDRESS 414 SW 140TH TER NEWBERRY FL 32669-0000 ELLIS ENVIRONMENTAL GROUP RUSI B CHARNA 414 SW 140TH TER NEWBERRY FL 32669-5400 Base Amount Penalties Other Amt Paid 131.25 131.25 PAID-6027312.0001-0001 1608/02/2007131.25 VON FRASER, TAX COLLECTOR P.O. BOX 1439, GAINESVILLE, FL 32602 (352) 337-6227 nns LOCAL III'SI'l:SS T,\\ lu:n:lI"r 1l()E.~ '0'1' CO'HR\I THAT Rt:GIll.ATORY ZONI;IIG IU:QURI.:\n:;IITS IIA\'Io: IIt:I-:N \It:T. IT IS nlE OW't:R'S RESPO;\/SIBJI.ITY TO F.NSlIRI:: ('OMPI.IANl'F.. ---.--" /AI~' &~ /0" ~.;- /J5~ 09/28/2007 08:14 FAX 904 744 2446 RANDY FRIES r- ;:;. n. ;l '" n 6r ;;.< "' en ~ co ~ VI n: "" n :r. = 8': t1l ~ o n ::T e? ~ o t:: ;l P- o ... ::r (> P--j O::T "' -. u; ;r. -.c -r. ~ g t1l'1:l :1 c: -6 =. -0 ~' ;l ::T I>> n - ~;:;. g g ~ ~ 00- ::t>g o ~ 3 ::l ~ sa. '<'i ~3 0. -. .... - ;:r5" g en fi' o g o '" ... n (1; ~ -0 C\l 0- 9 .,. ~.~ - ~ [n o s ~'< '< C1I r:r ~. (D ~ ri S' .Q lJ:l C ... ~'CJ~ -=...c ;;,..:;;- '<0' -"" to: '< ~ c . ... N g 5' 1J'Cl E;" ~ '" o -, :;. <1> ~ J:'r n ~ a ;:;. yo o ... g. o' _V) ::l o ... -0 -0 -J '-~ S. ~ 3 =:- Cl: 0 Ilol g~:e o Co @ """,.c Q) == I:: gs:~r :T~c.n ~;:=r ..".. 0 en' l:: _'_ =~ r.;' (:;.-g g (') (") u: ::3 ::::.0 ~gs S' 0"' x~~ 0'A>9: .... =~ S-~i>> 01 -'< e? ':; a. ::i C n os..o cr-o~ !5; ~.=. =.~ a 5 c. 0 '" 0 c: ~'" Sl '" -00-< a~~ ir;;s- '" -. Cll o' Er-O :::Jn~ o n n -. 0 (1) ceo 0:::1_ p ~ r::r -a' S; 1'0: c:::-. g.'8' ~ p ::l ~ ~,S' ~.~ ... 0 o :T o~ 0.. ::l o 2? w~ ~ -... ifEr -"" r;-: Cll ;I .., '" '" <1> ::J "'r:r '" Cll ~o =-g r:ro I1l _ v' 0 5-Er 0'(""", !:1. ~. _r. o :e s-o Cll -, ::T (b - ... Z . >= nr.n ~~ 0- ==~ t::lZ >r.n Z~ n- ~rJ) "'!j ~~ ~~ >r.n ~= >~ n~ ::c", ~~ >~ r.n ("""}~ O~ ~ , 2-1 -1..., <0 ~~ ~O Z~ >t::l Z> nf:l:l tI:l..., ~> -..., .:..~ ~....:. ..., >~ f:I:l(":) ~~ Z"" ~l;!j ~~ t::l~ Ut ..... 2: ~ o ~ - ~ - o z o :z ~ 0< .. Xl ~ 3: o < ~ o ::0 ~ o ~ t::l = l:'!:l == - Z ~ = ~ ~ o ~ -= o f:I:l ~ - 2: ~ ~ - ("""} t2'j Z f:I:l l:'!:l "'C 1.:> . < Cl:lO Oz X'Tj z:;::o 'oN ;I> ~\OV) ~.. en t..JO~ ....' ;I> . YJ-'"'l ~Z;l> o-.~X 1..J < ~ !jr:O rr trJr-' .trJ ""Q rO :d~ 0- o 1..J ~ () ~ ;; e; ,..~ "'0 .;II") ~p :it .... !:l~ ~I= ;;~ :-t~ :;!i. ;;;~ ::!g j;jc: =>z ~S ~2 CI:':v. ipi :;~ ~-l ~~ ..~ ~.. 3~ d~ ~e "'.. ~~ ,.;~ S!i :;;r: ,.. >= :>i I"l l" ~ o g; '" QI CD .... '" o o o ... 8 ~ z...::um m.~E ~ca-en m:!:UJm ::u...oz ::o.~< -<0 - -4 ~ "T1:I:zO r""-4>Z [:::lm 5:, 8l::U 'P ~ ... 0> o l! '" ~ '" 8 CD - t.l ... j,) Ul :~~;rJ.~~':';'~~~ ~E~ ;1>0' oC: ov> ;;r:lz ~rn en en ~ c:: en Z tr7 V) iJl -l -< m '" ... ... IV i5 z~ ~~ !pen m=E ::0- ::0'" -<~ "T1:J: r""-4 - ~ iv U1 ... t.l ... N Ul t.l ... N UI ~002 I\) o o en . o ...... ~ r- s:> en V2:C -l~ ~> on t'"'wO n"tl<= [TlC-Z ~?<~ rnm~ t!'lClO ~....; "tlZn ;3>ri trlnC= C/)O"'= CZ> ~V2-..J v.J"'1::I'""' .e ....- 0 0(') -..JC::2 ~~ "'Ct"'" r-- >r'} (')~ tT12 rJ) tI'j '" t.l ~ ~ ~ ... ... c.>;> ~Ci .... Ci o Co Z -; Z o Owner'. ...m" TO: 7800021 L.r.rI1TKnIL~ lSUlLU11'L ~AA NO.lllj-ItW-UU.!1 .L,.tlY UI ~"''''"''''.Q . ~..".... ..,..,....-~..-.. . . . , ' Bulldlnll oepartrnl!lll ;'; , P.2 r. UUl "1D YI' . NOV-2-2007 09:S4A FROM: Ul;T/jU/LUUI/TUl! 1 u: ~j AM 813-;/80-11020 ' ..i', . . '. :""f. D"'''~~I;,{ci : , ' 'W{~.i' Phail!t l\1~b.r ' .,':: :,!',,: ,:-.Pil~N~l!e~l F.~.S~~~.l1~.h.ld.'N~.. .".... ': ~ ~. " ".. ,', ':.., . .. .'. .': ::-';--'7Z(7~,,~,,'C?;~~'<~~d ." .....l~~.,.~> SUBDIVISION.,. 1 ., , i, PARCIlL I" -' .lo.rAIlI!D"'OM~TAI;lNcm"I.. , ,> ." ,,' '~, .', 81, .GIII,:,..,' CJ '.... ,Me, V. i..,",r"""1.' ',," ..'ti~MOL. ' IS,,! waM~~p~~=:.:,",: ~..,}~~~~S1~~.EL.',~~T ~ "". .... ,~ t. ' PR,opci8IiDUS~ "'" D. ~F.tl " 0 COMM,' D.'D!"~ I ' TYPE OP CONSTRUCTION '0' BLOCK, D ' .,' FRAME . 0 steEL:' 0 ~~.:.... IAh~~ :9~.~.~:it4'" P..'j~' '. . BUlLDlNO'.wr. J. "," ,.... f... .Q;,O~AGE~':' 1 ',~: tlEIGtrr ~. q": Bll!~I~(r ' '.-l'. j2.';~~.c/.;~, '.1', .V,,~u"TloNa~.Tof~i:O.N8TRU~~'''', 0' .,~~~r~:.,.J, /~'~~~:".~D."'.. ,... I '. ~~E~CE. q:',.~~.ES~~~RG~.:.' ,,~,C1: ' VI.R.e.C. d, . ,PI.U~IIINQ" 't:'.: ' ,t "":',.' ' .1'. .... "" ' .'., ,'. , . '~:: ,.,,':. . ',..,',, . '0' MECl.fANtCAL." I" , '" :" .' I- ','VAl.UA110MQFMecHANIc;lL:INST~no'.' ': '0 "':GAS ;..:.,'..,::~I';.~:~~:::.,.. T::J".:.SP~c1A1:~EJ:~"'~~.:/.' '., ~:."'" ',~: ',. ,. 'FIN~S~EDF~~O~.E.i.EvATI.~~!l.L .'"'' ,". .:..'. ' .J. ',~~Z~~MeA,':: ~...:.~,,~s.q~,~,t .;: :'. :, ~ . . .' . . .... . . .. . .J "';1 artiER I uP ':...' '1,,' 1: '1 r -.J n.~ 'M&CHANlCAL 81GNATURE , ~d~... Add,... : "':' .1~/WI~/c,~,i;;i~i1~' I , . 1:1-.'" .1&l;C()~:V19' I .: COM~~ . M""t~ \~f\Gcel~~'ri\'t(!~~S~~"L ~~~{'t~ IlhIIlTl!RlD' I" I N h ."'~' ': EYltJ. , .1.... 'Lle.naet 1e:~"C'C()~J.f~~ I 'r " " . .. ". I I Y J N, I, 'PlBCURRIIIf1..' ~ , BUlLDIR liIG~TUR.." AcIc11'H. PLUMBER SIGNATURE ' , ' Add....: OTHER" " '\ ~IGNA~~ " \ ' Add.... ' , '. .... . .'. :.. . ',1 1 ..... ~ CUIllllNT M, .. ,,' J.' ';, ... RE81D~"'" ~ilaC:h(2)PlciIP~"'afluUdlnoPIIIll;(1)~~ElieiaYI'aml'~~P.ermllfar"ew,~\lIIO~.. ' .. " . : .-. '.' ," MlnImUlll.,,(10).' cla,...fler8llbm1llaIcl'Ie.,RaqIlImlan.lla,C_~lIflAens,S~"'P"nurlSlllFenlllllnalllltldl . ': .,Sll!1Il8IYP.c:lIIdt!l',;~laf.8IteWa,kPennllfa,.uW~pl'O/lICtI " .:, .. . '" " COMNI!RCIAL. AIlaDh(3)....afeuJdlnilPllrie:(')utafEIl8I1lY..aI'in..;R.g.'WPoirm.larnllWllDlII~. .' .,' ".,.. .. " M1nlm..m .... (1 0) ~ lIep .r MlMIIItaI dale. Req\llred and.. ConiIlnlclIIon Plena. 8lann__ ....' wi ~I'l t=o...llrallllllld. 8lInlllly FaclMd.. , 1 "'lIIIler. 8118 Wark p_1t far ,II ~ praJlICtI. All c:am/llllfdll ",-,"*'III mllll meet ODIIIpIII- ' SIGN P...,.IT AIIBaI1 (21.m al Ei~ p,.... '.. , .' . . .: . . . .' . '*"PROPI!R~SUR~~fDl:~IEW~1lan: \" ." ' .: ;" I OlreDtI_: . .'... , . . ': : .' . . Fill aul !lppllalllon c.am"l.~., . .! '. ' , 0wMt , Olnltllclanlpn beck vI 'Ppllc;l~, nolllllDd ' . " , """" I2lDO, . ~.. lit c.i"",!.IIll~~ .. tiI..u~"", I~....."... _r SIll... .. AiI..ritciru,;; ixmln!_lerPa-r of ~ (far lhiI alMMI.Wai.I_ samlllllll willi na~ I"""". -,~ ~_. 'OVER THE COUNTIIR PIiRMITTING ,jpratit 01 Apj.uc.1lan only) .': . . ' R8flIafs. '. ,.8_.' ~ervlce Uiio~' , ,A/C, . "...,.. (plpt/llUlVly/Fciallllel' D~.,..Nol aVer Coull....., On pUblIC !"dwIye.:,..:RQW .f City of Zephyrhills: Phone: (813)-780-0020 FAX: (813)-780-0021 Building Dept. -----------------------------------------------------------------, : TO: Roxanne FROM: Jackie : I I : FAX#:813-971-1567 FAX#: 813-780-0021 : I I : DATE: 10-30-07 # OF PAGES: 2 : I I I I I I ; I : MESSAGE: : I I : Attached with this cover page is the permit application which I would need for the : I I : electrician signature, name of company & state license # and address. : ! I : Fax back to # at the top of this form. : I I I I I I I I : Thanks Jackie : I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I : I I I I I I I I I I I I I I I I I ---------------------------------------------------______________4 Contractor/Homeowner: City of Zephyrhills BUILDING PLAN REVIEW COMMENTS ~ 1+{11Jmf""~ ~~ GA:S {t7 G~/-6)'i;'1~' . ~ 9-27-0 "1 Date Received: Site: Approved wino comments:D Approved withe below comments: ~~enied withe below comments: 0 h/J' · t Vir? tf .J ~ l1ecJ ::me l ,/M1r{/25 I I Permit Type: D ~~ I'\A~,)AL ---1 ~\J ~C.JL ~\li p:.tI'J , -- ar /)~,,- , J ' ~\~ ~~r'- ~ 1bis comment sheet shall be kept with the permit and/or plans. Bill Date LJdf~ ~ .~ ' . ContrRctor an or Homeo'WIler (Required when comments are present) ..________~. no. ~ , . City of Zephyr bills ; 'BtmnIN'G PLAN REVIEW COMMEN'TIS Site: /)// Am~'C4/l ~~-k~~. f()- CI- () 7 31</zJ S~ .~ ~ (f;.I.;!/L"j Tautiy (}dJ ContractorlHomeowner: Date Received: Permit Type: Approved wino comments:D Approved withe below comments: 0 . Denied withe below comments: 0 This comment sheet shall be kept with the pemiit and/or plans. Bill Contractor and/or.Homeovvner (Required when ccmnnents are present) Date '-~;- {. -~~!.,,; .,....,~,..',., _ _'-8114 ...., -": -..' ,"" '",", .(jU :'- '.... ~\.....,,:"""'-~ ;! .~...... ~.':::.: ~ '.R-l\'IE' ',\.~T -' _. ..J j lY j'l. - - ~ -'.' -. .-' .., ..._ ~ ;~:L, _ ,:: '... j ,- 23.:42 ~~.s 3 :'}Y72C-(C4 - ~L( ,3!': -3G_.JIJ~wJ. FIRE SERVICE USER FEES .....- Occupancy No.: Plan No.: Business Name: Business Address: Business Phone No.: Business Fax No.: Contact: Own.c J/,~~~ ~ Billing Address: :y- (. "";R'~ Billing Phone No.: 7#"7- ~1.4./ .1...,rr- 3'2.-~ Billing Fax No.: Contact: ctf7;;; ~/;ff PLAN REVIEW FEES B Site Plan N/C Multi-Family/Commercial .06 sf (Minimum Charge $25.00 o Plan Revisions DBL SPRINKLER SYSTEMS B 0 - 25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 FIRE PUMP o Per Pump $100 FIRE ALARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS ~ :~t :~ C02 ~ Othelr $50 KITCHEN EXHAUST o HoodlDucts OTHER l slallation per tank Fuel Tank Installation Natural Gas Installation Spray Booth Comments: INSPECTION FEES Annual N/C N/C $100 $250 $500 PERMIT FEE ~ $50 ~ $50 $15 ~ ~ ~ FALSE ALARM FEE 1st Alarm N1C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 ,/ ,/ FALSE ALARM TOTALL l ppres5lon S m Acceptance B Exhaust Hood/Duct Re-inspection (other than annual) o Inspection schedu and cancelled I than 24 hours Bconstruc' n Insp. N/C lti~l Emerg cy Vehicle Ace $50 PLANS TOTAL~ INS CTION TOTAL I m_J Hydro Undergrounds Hydrostatic System Wet Acceptance B GRAND TOTAL .L(D PERMIT TOTAL~ 10t>~ ~ Date: /O!?-~ !lIh 81 :3- i 80-0020 L;lty or Lepnyrnllls r-ellllll MjJjJllvdllUl1 Building Department '10 (/f Fee Simple Titleholder Name OWner Phone Number e /,3 - 780 - 0 () tf) 6 V.llLOwner Phone Number I OWner Phone Number I Date Recei"ed OWner's Nama OWner's Address JOB ADDRESS Fee Simple Titleholder Address I I 39'f2/ .souT/' I Ave Ze;Djyr~//1.r, /L I PARCEL 10#1 LOT# I SUBDIVISION WORK PROPOSED [8] NEW CONSTR D ADO/AL T 0 D INSTALL D REPAIR PROPOSED USE D SFR D COMM 0 TYPE OF CONSTRUCTION D BLOCK D FRAME D DESCRIPTION OF WORK I AI> aYe <] rou h oI-f(,(.e/'/)~ I'ac;'/;",J BUILDING SIZE I sa FOOTAGE I I HEIGHT I II I I I , , , I I III I , , I r , I P I I I I , I , I I I , . . I r 11 I I . I . . I I I II I I ~ , , I , I I' 111 II I , , I I . II I I , I I . I II . I I II , , II 111 f I II I I II , P , I III1 , I . III I , I II" I , , , II , , . r . I ,I I . I I , till I (OBTAINED FROM PROPERTY TAX NOTICE) SIGN D MOVE 0 DEMOLISH OTHER I STEEL D OTHER I D BUILDING 1$ , 3 2- 9. h LI'I. 77 . D ELECTRICAL 1$ /9 S'OO. (JO .) D PLUMBING 1$ D MECHANICAL 1$ 9; 6cJ2,cJ() , D GAS D ROOFING FINISHED FLOOR ELEVATIONS I VALUATION OF TOTAL CONSTRUCTION AMP SERVICE D PROGRESS ENERGY D W.R.E.C. VALUATION OF MECHANICAL INSTALLATION D I SPECIALTY 0 FLOOD ZONE AREA OTHER DYES DNO BUILDER SIGNATURE Address COMPANY IAI/ /!mer;'CCfI, COJlCI'e-f-E5 ~c... REGISTERED I IT2J N J FEE CURRENT I C'OI N I License # I CG C 05 If /9 C; <.~~~ ELECTRICIAN SIGNATURE COMPANY REGISTERED Y/N FEE CURRENT Y/N Address License # PLUMBER SIGNATURE COMPANY REGISTERED YI N FEE CURRENT Y/N OTHER SIGNATURE J;ci.UJ/l v/~ I License # ....... Address MECHANICAL SIGNATURE FEE CURRENT Address License # ,. W-loc:ro8Z..7- COMPANY REGISTERED Y/N FEE CURRENT Y I N Address License # 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111'1 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onslte, Construction Plans. Stormwater Plans wI Slit Fence Installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivlslonsllarge projects COMMERCIAL Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wI Slit Fence Installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ....PROPERTY SURVEY required for all NEW construction. DI~~~ti~~~': . . , , . . , . . , . . . . . . . . . . . , , . . . . . , , . . . . . , , . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . , . . , . . . . . . . . . ~ . , . , , , . . , . , . . . . . , . . . . . . . . . , . . . . . . . . . . . . , . . , . . . . . . . . , Fill out application completely. OWner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement Is required. (A/C upgrades over $5000) .. Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades Ale Fences (PloVSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrir;tions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance 'It th any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse. Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate. of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development reglJlations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to Identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of. Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitthlg which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand ~hat a s.eparate perm~t. may ~e requir~dfor elect~ica.1 work, plumbing, signs, wells, pools, air conditioning, gas, or other ~nstallatrons not speCifically 1n~luded. In the application. A permit issued shall be construed to be a license to proce?d With the work a~d not as authorl~y !o. vlolat~, cancel, alter, or set aside any provisions of the technical codes, nor shall Issuance of a permit prevent the B~II.dlng OffiCial from the~eaft~r requiring a correction of errors in plans, construction or violations of any codes. Every permit Issued. shall become. Invalid unless the work authorized by such permit is commenced within six months of permit issu~nce, or if work authorized. by the permit is suspended or abandoned for a period o~ six (6) mo~ths after the time th~ work IS commenced: An extension may be requested, in writing, from the Building OffiCial for a period not to exceed nln~ty ~90) da~s and Will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, th~ob IS conSidered abandoned. WARNING TO OWNER' YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR O~ICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) , OWNER OR AGENT Subscrtbed and sworn to (or affirmed) before me this by Who Is/are personally known to me or has/have produced as Identification. (). 'loP Oc- 1- Name of Notary typed, printed or stamped Name of Notary typed. printed or FL NoWy DIsCOUnt f\aO<;, Co, Notary Public Commission No. Troubleshooting Guide - English Version Tr ShH15891PAE.pdf Troubleshooting Guide - French Version H15891 PAF.pdf NOTES & WARNINGS NFPA 30-A Automotive and Marine Service Station Code (9-1.2.1) At any installation where the normal flow of product may be stopped other than by the hose nozzle valve, such as at pre-pay stations, the system shall include listed equipment with the feature that causes or requires the closing of the hose nozzle valve before product flow can be resumed, or before the nozzle valve can be replaced in its normal position in the dispenser; or the nozzle valve shall not be equipped with a latch-open device. WARNING Do not use OPW 11A nozzles with a hold-open device at installations (such as prepay) where the normal flow of product may be stopped or started by means other than with the hose nozzle valve. I Jse the OPW 11 B or the OPW 11 A without a hold-open device. Failure to comply is a violation of NFPA Code 30-A, and may create a hazardous condition. Use of foreign objects to hold-open automatic nozzles could result in failure to shut-off and personal injury. NOTE See OPW's Website at: www.opw-fc.com for product instruction sheets, trouble-shooting guides, how-to-use guide and to view the Do's and Don'ts at the Gas Pump video. RACK REMOVAL WARNING 11A Full Service Warning for Rack Removal H_1 01 01_PA.PDF ~MPORT ANT: OPW products should be used in compliance with applicable federal, state, provincial, I and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ a::.....)"_ '\ ~''"l'......tio ~NGsfe,(7H) ,. For Heavy-Duty, High-Flow Truck, Bus and Fleet Service If you operate a full-service truckstop, refuel your own fleet or manage a cardlock refueling location, the low cost, long life and durability of the OPW 7H@ high flow nozzle can help increase your productivity, sales and profits. . Table of Contents: 1. Features & Benefits rlow Charts ~' 3. Ordering Specifications and Replacement Parts " - 4. Instruction Sheets 5. How to Use Nozzle Guide 6. Troubleshoot Nozzle 7. Notes & Warnings Features & Benefits . Spout retaining ring - adds extra measure in securing nozzle spout in fill pipe. · Helps reduce spills - a unique two-stage lever design assures a positive shut-off, even if held wide open. · Design Working Pressure - OPW products are designed to work at 50 PSI maximum pressure. · Three-position hold-open device - one-finger control of hold-open mechanism means easy setting of flow rate. · Easily replaced spout - simply remove three screws. Replacement kits are readily available from OPW. · Dash-pot action - for smoother closing action and reduced line shock. · Dual poppets - easy to open nozzle against high pressure. · FlowLockTM - designed to shut-off automatically when the spout is tipped up, limiting spillage. · Low reliable shut-off - specially designed to ensure proper shut-off as low as 5 gallons per minute. · Even, smooth spray pattern - minimizes diesel foaming and false shut-offs. · Listed by Underwriters Laboratories, Inc. - UL Listed. Materials Body: aluminum Lever & Lever Guard: Duratuff@ Packing: Graphite with Teflon@ Disc: Viton@ Inlet Size: 1" NPT Weight: 3.35 Ibs. each, 52.05 Ibs./case of 15 1.51 kgs. each, 23.6 kgs./case of 115 UL Listed @ ULC Listed @) GPM fa ~ lOa II! I,. LPM 40 o o 10 20 30 . 10 10 70 R.OWRA.1&GPII (8TCDDARD SOLVENt) 2.5 2.0 1.5 1.0 .5 o o .. 80 120 180 2GO 240 280 Ordering Specifications Green 7H-0100 7H-5100 See PNET 2006 " '".(,,'," .,,",-' :..'c.: .""-'''_~''',''J:'''.' Yellow 7H-0900 7H-5900 See PNET 2006 Replacement Parts ~~ ~ !~< in. mm. in. mm. Ibs. kg. Ibs. Spout Kit 5BHB-0125 1 3/16" 30 12" 305 .90 .41 7H@ (w/o ring) Hand Insulator See Nozzle Accessories 7H@ *spout endwith anChorr.rt~fi.131/64" 0.0. **For ordering specifications not listed in this catolog, contact OPW Customer Service. OPW 5BH OPW 5BHB NOZZLE INSTRUCTION SHEET Instruction Sheet- English/Spanish H15889PAE.pdf Instruction Sheet- English/French Conv InstH15889PAF.pdf ************************************************** SPOUT REPLACEMENT 7H Aluminum Spout Kit W/O Adapter H08336PA.pdf ************************************************** HAND INSULATOR REPLACEMENT One-Piece Hand Insulator Kit H10652PA.pdf ************************************************** RACK REPLACEMENT 18KV A H_13156_M.PDF 18KR, /10150PA.pdf ************************************************** RACK REMOVAL 7H Full Service Warning For Rack Removal H_1 01 01_PA.PDF ************************************************** "- How to Guide - English HowH 15893P AE.pdf How to Guide - French H15893PAF.pdf How to Guide - Spanish H15893PAS.pdf Troubleshooting Guide - English Tr ShH15891PAE.pdf Troubleshooting Guide - French H15891PAF.pdf Troubleshooting Guide - Spanish H15891PAS.pdf NOTES & WARNINGS WARNING Do not use OPW 7H nozzles with a hold-open device on pre-pay self-service installations. Use the OPW 7HB or the 7H without a hold-open device. Failure to comply is a violation of NFPA Code 3D-A, and may create a hazardous condition. Use of foreign objects to hold-open automatic nozzles could result in failure to shut-off and personal injury. WARNING FOR RACK REMOVAL Full Service Warning For Rack Removal I'C101 D1_PA.PDF / IMPORTANT: OPW products should be used in compliance with applicable federal, state, provincial, and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C> PVV+ &>-,- ~ OPW 68 lIreekaways (8EAQ The OPW 66 is designed to be installed on fuel dispensing hoses, and will separate when subjected to a designated pull force. The dual valves seat automatically, stopping the flow of fuel and limiting any fuel spillage, while protecting the dispensing equipment. For proper operation, the OPW 66V-3/4" must always be installed with a "straightening" hose with a minimum length of 9", such as the OPW 66H. The 66V-1" must be installed with a minimum length of 12" hose. Table of Contents: 1. Features & Benefits 2. Flow Charts 3. Ordering Specifications 4. Additional Resources 'Jotes & Warnings Features & Benefits · Pull force - the 66V-0300 will break away with a pull force less than 300 Ibs. The 66V-1300 will break away with a pull force less than 300 Ibs. · Certainty of operation - designed to be replaced atter separation, instead of reassembled, to protect against reassembly errors. · Unique double-poppet design - features low pressure drop. · Low pressure drop - the integral check valve design allows for minimal pressure drop for faster, high-volume fill-ups. · Listed by Underwriters Laboratories. Inc. - Visit our website at: www.opw-fc.com for specific listings. · Design Working Pressure - OPW products are designed to work at 50 PSI (3.45 bar) maximum pressure. · 66V-0492 UL Listed for E85 & E100 fuel blends. Materials Body: aluminum Middle Coupling: die-cast zinc Disc and Seals: Viton@ Springs: zinc-plated steel Static Seals: Buna-N Dust Seal: neoprene UL Listed @ ULC Listed ~~ GPM 20 1- if It 15 i g 10 I m 5 It: a.. 0 o 10 20 30 40 50 60 FLOWRAT6GPM (STCDDARDSOLYENl) LPM 2.0 1..5 O.t o.s o o 40 80 120 110 200 240 1- ~ y " 314" i/ " .." / ./ "/ -- /" Ordering Specifications ~ in. mm. Ibs. kg. :31"~~ '~'~;~i_ffJ, . ..... 66V-0492 3/4" F x 3/4" F (NPT) 19 F x 19 F 0.60 tt~~~~1~' '" ,,,~~~~~~:!t~~,-:;. 0.45 Valve/300 lb. .'..,..:.':..' -,'.. '-.. ^ "<':.:.: .,.::,,':', '4.'"; '".s. ~;':i'i"~'::::,_ ,~ .~,~" 66-0075 3/4" F x 3/4" M (NPT) 19 F x 19 M 1.46 0.66 Valve wI 9" Hose/300 lb. - ..-.' -,' -.--,....', VS1_Y!11~' ' 66H-0075 3/4" M x 3/4" M(NPT) 19 M x 19 M 0.75 .~~~).t. 0.34 9" Straightening Hose ,j;,~" '-"~Q' 66S-0075 3/4" 19 0.20 0.10 Vinyl Scuffguard Cover For ordering specifications not listed in this catolog, contact Customer Service at 1-800-422-2525. 66V-0250 3/4" 66-00753/4" Installation Instructions 66-0075.PDF Installation Instructions 66V-0250.PDF Installation Instructions H10993PAC.pdf 66V Canada Installation Instructions H11043PA.pdf 66V - 1" Installation Instructions H11833PA.pdf 66V - 1" Installation Instructions H11505PA.pdf 66VL - 1" (150L) Installation Instructions H11015PA .pdf 665 (66V Cover) Notes See OPWs Website at: www.opw-fc.com for product instruction sheets, trouble-shooting guides, how-to-use guide and to view the Do's and Don'ts at the Gas Pump video. ?ORT ANT: OPW products should be used in compliance with applicable federal, state, provincial, and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ ..:>-1'- '\ Q9W241TP& Hose Swivels (241TPS) U1TP8-314" The OPW 241 TPS Provides Two-Plane Swiveling Rotation For Easy Nozzle Positioning and Reduced Hose Wear The OPW 241 TPS swivel is designed for applications where easy nozzle and hose handling is important for customer convenience. The OPW 241 TPS is installed between the nozzle and hose to reduce customer strain, provide flexibility and reduce premature hose wear. Table of Contents: 1. Features & Benefits 2. Flow Charts 3. Ordering Specifications 4. Notes & Warnings Features & Benefits . Customer convenience - provides customers with the flexibility to fuel their vehicles from virtually any direction. . Two-plan rotation - the first plane (at nozzle inlet) allows 360 degree swivel action for easy rotation of the nozzle away from dispenser. The second plane (at hose connection) provides 270 degree swivel action, for easy nozzle positioning in fillpipes. In addition to the customer convenience benefits, the unique two-plane rotation helps reduce hose kinking and premature hose wear. . Compact, attractive profile - provides a sleek, modern appearance, allowing hoses to hang straight down instead of at an angle. . Secure design - not repairable or rebuildable for certainty of operation. Every OPW 241TPS is factory assembled and tested. Dual seals - added protection vs. thermal and chemical degradation. . Design working pressure - OPW products are designed to work at 50 PSI (3.45 bar) maximum pressure. · Special swivel outlet design - the male adaptor is specially designed such that tightening of the threaded joint will not inhibit swivel rotation. . Listed by Underwriters Laboratories, Inc. - for gasoline, E85, E100, and M85 gasoline blends. See our web site at: www.opw-fc.com for specific listings. . 241TPS-0492 UL Listed for E85 & E100 fuel blends. Materials Body: aluminum Inlet Adaptor: zinc P11let Adaptor: zinc . als: Buna-N, Viton@ Bearing: nylon Weight: 3/4": .65 Ibs., .30 kgs. 1": 1.55 Ibs., .703 kgs. UL Listed @ ULC Listed 8 GPM 18 1. I :: I · i I i · 2 o ~ v / 1. / ~ / M't I -' " - } ,,/ ,,/ .;'" ...... 510162025..4045..80 FLOW RAT&GPM LPM '.1 1A 1.2 t .. .. A .2 . J , ~ 1. J ",;, " " - ,/ .... .,.,.. .......t" --- ~ 11 S7 5& 7S M 11S is! t11171 1.201227 Ordering Specifications A B ;c'i1i;:':h :""""",~:~Li'~~'ii;#.h;}";;'"",: ,c<.' ."..,, """~j 'j ,..., ,.. '. ' P'llJ"[l' 'Ix.'v~, '. tnL ,J' ~IU"I[Ull,l___ ...,.,..,., JJJU~JJU _"':'<P::i,,~';l\"J:~I~ ......--. 19 mm. x 19 mm. 124 mm. 56mm. . ..,.;<:...,,_._..,........_;...:,.'.',.-;: '_',".'m' . 25 mm. x 25 mm. 153 mm. 64mm. ..""..... .twI..,. .~,.i;..j;U!S ..~,). ~:-' ," .. . -~'::>:~:nlt~: ~N1;r:"-1~;:> .. ..""X!.:::.,.:_',," C';.":._,: ,~..i...._,."..".-'-.i_.-'.>,<,. . 19 mm. x 19 mm. 124 mm. 56mm. For ordering specifications not listed in this catalog, contact Customer Service at 1-800-422-2525. Dimensions A 'I B 1 NOTE: See OPWs Website at: www.opw-fc.com for product instruction sheets, trouble-shooting guides, how-to-use guide and to view the Do's and Don'ts at the Gas Pump video. Advanced environmental protection, serviceability, safety and flow .~', a VEEDER-ROOT Environmentally friendly features The Red jacket Submersible Turbine Pump has been specifically designed to eliminate spills that can occur during service, and to integrate with Veeder-Root industry leading leak detection systems. Service spill elimination Innovative Check Valve design The Check Valve on the Red jacket Submersible Turbine Pump has been designed so that it can be raised, providing a larger path to depressurize the line and return fuel to the tank. This feature eliminates the potential for fuel~ills. ..>J!dlqree extractable When the two nuls holding the extractable in place are backed off, the o-ring seals are automatically broken, releasing pressure in the pump and the non-isolated line, draining fuel back into the tank. This simple feature helps eliminate potential human error that could cause service spills, protecting the environment from fuel contamination, and site owners from related liability. Vacuum monitoring applications RedJacket Vacuum Sensor Siphon System The Red jacket Vacuum Sensor Siphon System is a monitoring-grade siphon system. It is designed specifically for use in vacuum monitoring applications, and to integrate with Veeder-Root vacuum sensors. The pump offers two siphon system ports. The Red jacket Vacuum Sensor Siphon System incor- porates a redesigned one-piece rubber Check Valve with an in-line filter screen that reduces the dogs and failures that can cause false alarms and downtime in vacuum monitoring applications. Line leak ~etection Veeder-RootJRedjacket industry leading pressurized line leak detection (PLLD) provides environmental compliance without the fuel flow restrictions of mechanical (MLLD) or electronic (ELLD) systems. Protect the environment. Check Valve pressure release RedJacket Vacuum Sensor Siphon System Specifications Designed for Hazardous Location: Class 1, Group D atmospheres Siphon Ports: 2 available, 1/4" NPT. Vacuums generated up to 25 in Hg. Quick-Set Adjustment Range: RJ 1 = 74.5" - 105"* RJ 2 = 104.4" - 165" RJ 3 = 164" - 225" * Assumes 1.5 HP Fuel Compatibility: Diesel 100% Gasoline 80% Gasoline with 20% TAME, ETBE, or MTBE 0-100% Ethanol 0-100% Methanol Agency Listing: UL cUL ATEX Certified Line Pressure Port: 1 Available. 1/4" NPT 4" Horsepowers Available: 3/4 Hp, 60 HZ, I-phase 1 1/2 Hp, 60 HZ, I-phase WltIIMr IT. ", .llIfL X3, 60 HZ~ase X4- 'i0 HZ, I-phase or 3-phase 50 HZ, I-phase Vent Port: 1 Available. 1/4" NPT Just part Of the solutions offered by the Flow Resource at Red Jacket We offer a range of solutions, including leading pump technologies for both new installations and upgrades, manifolded pumping systems for increased uptime and product availability, and the industry's leading tank monitoring and leak detection systems. All with the desired purpose of deliv- ering greater profitability and reliability to our customers. We are a valuable source of expertise and informationlo both site owners and our business partners. Consider us your Flow Resource. Call the Flow Resource today for more information on systems design and complete product specifications. 800-323-1799 For inside sales call 1-888-561-7942 a VEEDER-ROOT ~ 2004 Veeder-Root Company . 125 Powder Forest Drive . Simsbury. CT 06070 . USA Telephone: 860-651-2700 . Fax: 860-651-2719 . www.veeder.com PIN 0576047-083 Rev.B VRRS 212004 Printed in USA - 'PORT ANT: OPW products should be used in compliance with applicable federal, state, provincial, and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ a>_j_ OPW 10 Series Emergency Shut-Off Valves (i--r.10BFC 10BFP 10FCP 10SBFP 10SBFCP 10RF 10RFP10RFSP10BM10BMC10BHMP10BHMCP10SBHMP10RM10RMS10RMSP10RMP 10BU10BUC10BUP10BUCP10SBUP10SBUCP10RU10RUS10RUP10RUSP1OS477110RW- 4735) OPW 10 Series Em.ergency Shut-off Valves are installed on fuel supply lines beneath dispensers at grade level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks off at the integral shear groove, activating poppets and shutting off the flow of fuel. Single-Poppet models shut off supply flow, while ,r ,...ble-Poppet models shut off supply as well as prevent release of fuel from the dispenser's internal piping. The base of the Emergency Valve is securely anchored to the concrete dispenser island through a stabilizer bar system within the dispenser sump or pan to ensure proper shearing action. The valve base is secured to the stabilizer bar using a three-point boss mount system or U-Bolt Kit (not included); 10UBK-015 (1-1/2") and 10URK-0200 (sold separately.) Value inlet (bottom) connections are female pipe threads and outlet (top) connections are available with female threads, male threads or a union fitting. Other options include suction system models with a normally closed secondary poppet which maintains prime, and models with external threads on the inlet body which connect to secondary containment systems. Table of Contents: 1. Features 2. Photo 3. Ordering Specifications 4. Replacement Valve Tops 5. Dimensions 6. Additional Resources Features . High Flow Capacity - The primary poppet is held out of the flow stream while the secondary poppet is held normally open to minimize head loss across the valve and to protect the poppet seals from damage and erosion. True 1 1/2" (4 cm) and 2" (5 cm) body sizes ensure maximum flow. . Fire Protection - A fusible link trips the valve closed at 1650 F to shut off fuel supply to the dispenser. . Main Poppet Seat Integral to the Top Assembly - Having the main poppet seat as an integral part of the valve top assures a new, clean seating surface is installed each time the top is replaced. This design also ensures that the integrity of the seal between the valve top and bottom is verified during line testing and allows full inspection of the main poppet when the top is removed. . Duragard-Coat Finish - Provides superior corrosion resistance. . Reliable Shut-off - A stainless steel main spring, a feflon-coated brass packing nut, and a copper/nickel/chrome-plated brass stem are designed to prevent tar build-up and corrosion from interfering with poppet operation after long periods of normal service without activation. · Integral Test Port - A 3/8" (9.5 mm) Test Port allows the piping system to be air tested without breaking any piping connections. · Patented Thermal Relief Valve - Relieves excessive pressure build-up caused by thermal expansion of fuel in the dispenser piping system in the event of fire (double-poppet models only). · Low-Profile Tops - Female and Union-top double-poppet valves have a low-profile top to allow upgrading from OPW single-poppet valves without changing existing piping. · Multiple Mounting Options - Valves are boss-mounted to stabilizer bars in sumps and pans or mounted to bars embedded in the island with optional U-Bolt kits 10UBK-015 (not included). Versatile Combination Body (boss mountlU-Bolt mount) models are available to accommodate most mounting applications with one valve style. . Underwriters Laboratories - Listed for use with gasoline and 85% and 100% methanol. All OPW 10 Emergency Shut-Off Valves meet requirements of UL STANDARD 842. . Compatible with 85% ethanol (E85). Materials Top: cast iron Body: cast iron Disc: M-19 Carrier: zinc-plated steel Stem: copper-nickel-chrome plated brass Poppet spring: stainless steel Seal: M-19 O-ring Packing nut: brass, Teflon@ coated Inlet and outlet thread: 1 1/2" (4 cm) NPT (British threads available) *With black Duragard@ coating Notice: As per NFPA 30A, electrical supply to the submersible pump must always be disconnected before servicing meters, dispensers or emergency shut-off valves. Important Notice: When mounting the OPW 10 Series Emergency Shut-off Valves, the anchoring system employed must withstand a force greater than 650 ft. pounds per valve. NFPA Code 30A, Automotive and Marine Service Station Code, requires that the automatic closing feature of emergency shut-off valves be checked at least once per year by manually tripping the hold-open linkage. OPW recommends the use of PISCES@ Stabilizer Bar Support System for proper mounting of 10 Series Valves. UL Listed @ Photo ........l1lennIlf ......Y4Ihe AIr Jell Port ,... ... tlCful .....11 T~ ....... Female Threaded Top (Outlet) Connection Valves Ordering Specifications L With Containment ~ I -I[~~..,_~_l~filin,' T ~;~"*)i~<"'fj"o'''''''''''\k.A'f'1:l.III,,,; "",...<;11' ' ilmll".";.;.,",, ,,', 5725 1/2" t,tMr~ 10BFP. 5726 1 4 1/2" NPT Double Pressure Combination 10FTP-!: 10SBFP- 5726 1 4 NPT Double Suction Combination 10SFTP. 5711 1/2" 'RF- 2001 2" Single 1 ORFT-~ 5 NPT Pressure Combination ~~d..;I_ .~,.~ 1.~f iftil . Pt~r&'. .:' ":0""',";: ~_~__.I.'~,.-~<'i_:,_: Male Threaded-Top (Outlet) Connection Valves Ordering Specifications I..".. ~,;,' With Containment 10BM- 5825 1 4 1/2" NPT Single Combination Pressure 1 ORMT-! 10BHMP- 5830 1 4 NPT Double Pressure Combination 10RMTF 5851 1/2" /"QSBHMP- 1 4 NPT Double Suction Boss Mount 10SHMT '30 1.lt~ Z$lJ8 10RMP- 2004 1/2" 5811 P~$6Um C~inatiGf1 ~'l1dl~ 1ORMT- 2" NPT Double Pressure Combination 10RMTI 5852 5 Union-Top (Outlet) Connection Valves Ordering Specifications I ~" With Containment 1 OBU- 5925 1 4 1/2" NPT 10RUTC 5975 Single Pressure Combination 10BUP- 5926 1 4 1/2" NPT Double Pressure Combination 10UTCP 5901 SBUP- 5926 NPT Double Combination Suction 1 4 1/2" 10RUP- 2006 NPT Double Pressure Combination 2" 5 10SUTC 5911 10RUTC 5972 Note: All BSPP Thread Shear Valves must be ordered through Europe or China office. Ordering Specifications I in. ,t.t)RFT- ~50 10RFTP- 5751 1 1/2" 4 JSFTP- 5711 1 1/2" 4 cm. Threads Connection Configuration 4: NPT Double Pressure Female NPT Pt_S$11~' Female NPT Female Double Suction .~Mr..., . .sa'" 1 ORMTP- 5851 , t6SHM~; .1,1 . '....., 1 1/2" 4 NPT Double Pressure Male 10RUT - 5950 ,1l0Rtf <":~"~--,::::::':" ',: --'; -',.:'. ~9t5.... ) OUTP- 1 1/2" 4 NPT Single Pressure Union Base (less nut & tail) Low Profile 1 1/2" 4 NPT Double Pressure Union Base Low Profile ,.'01 j,OUTCP- $901 10RUTP- 5950 1 1/2.. 4 fitf3T 1 1/2" 4 NPT 10SUTP- 5911 1)OSUTCP~ ;59~1 1 ORFT- 5742 . cJRFTP.. 6152 1 ORMT- 5842 1 1/2" 4 NPT Double Double Q.~bf$ Double beqWe Single 90tfbJe . Single 10RUT - 5942 1,PRUTC- ,. :&962 .,. 10RUTP- 5952 :11ORUTCP.... tfPT ';y"-'.-.., 2" 4 NPT 2" 5 NPT 2" 5 NPT 2" 5 NPT Single :$tngle Double (less nut & tail) Pressure Complete Union Pressure Union Base (less nut & tail) R:fes$Ure~tnptete ~",jpn Suction LOJW Profile Union Base Low Profile (less nut & tail) Suction Complete (JAion Pressure Female Pressure Female Pressure Male ~(essute, .~le Pressure Union Base (less nut & tail) Pressure Complete Union Pressure Union Male Complete l_j~tofife \aniOn Other Replacement Parts I ~. H03955M Tetra Seal H07643RB Link Retaining Screw H05361 Safety Hub S/A-Fusible Link 1 OU BK-020 U-Bolt Kit for 2" 1 1/2" Dimensions 10SBFP 10SBHMP 10SBUP ~~:.: 184 .-.;, 195 7 1/4" 184 7 1/4" A 6 21/64" 161 621/64" 161 6 173 7 11/16" 13/16" ,~..'.,.".j1~.. 'Jut C 2 69 211/16" 69 11/16" 2 69 11/16" 211/16" 69 2 69 11/16" 2 11/16" 69 Key $$ /1 Dimensions .',._'_. 10RFS 10RMS 10RUS 10RFSP 10RMSP 10RUSP mtn" '-, I,":~~;~:~ 111m. A 83/8" 79 927/32" 79 9 13/32" 239 83/8" 213 927/32" 250 9 13/32" 239 ys' 1imli' - f9 ~o_~l'4~ " -~~. C 3 1/4" 83 3 1/4" 83 3 1/4" 83 3 1/4" 83 3 1/4" 83 3 1/4" 83 o 3:1:,16" ) 1n~" 9$- . \ 10 Series I nstruction Sheet H11374PA-instr.pdf 10 Series Main Office and Plant: 100 Four Points Way, Tallahassee, FL 32305 Tel: (850) 878-2558 , , For more information ema ma rketl ng@syntech-fuelmaster.co Benefits The best just keeps getting better! Fu.",."e;4 saves you money by eliminating manual tracking of fuel transactions and increasing accountability. The same reliable FuelMaster4 equipment that's been the fleet managers' choice for years has been upgraded to increase productivity and provide a quicker retum on investment... usually within the first year! FuelMaster4 engineers and technicians provide the best product support service in the industry. Toll-free support directly to your fuel island, as well as PC to PC training and assistance, saves you time and money. FuelMasterf/l doesn't stop there! Its flexibility permits numerous, diverse uses; e.g., a gate opener, car wash activator, or controlling access to chemicals, to name a few. Consider a FuelMaste,.e Fuel Management System ... and start saving money today! The FuelMaste,.e 2500 Plus series adds additional features that make it the most effective fuel management system on the market for many years to come. Flash memory has been added to permit updating the fuel island operating system without changing chips. The Plus system has increased memory and processor speed and the database has been upgraded to Access 2000. The Plus system also supports a network card to permit Intemet access. FuelMastef"J software now has more flexibility in the customization of reports. FuelMaste,.e also communicates directly with elec- tronic dispensers to permit interfaces with blended MPDs and the capability of remotely changing dispenser prices. Features Electronic ReadlWrite keys and cards are great for fleet operations or gas dub members. PROKEEfIIS are high strength, plastic composite keys containing nonvolatile, readlwrite memory chips, which can be encoded with confidential information to control access to dispensers and streamline product transaction data. FuelMastef"J's patented radio frequency tag system takes driver data entry out of the information collection equation. The odometer or chronometer data, along with other information is automatically collected by the island fuel management unit without driver effort. An AIM (auto- motive information module) unit is installed on the equip- ment and collects and stores information and sends it to the fuel management unit by RF during fueling operations. This system works concurrently with the use of PROKEEflls or smart cards so that the (AIM) units may be added to equip- ment currently using electronic readlwrite access devices. The FuelMaste,.e 2500 Plus' capabilities to support self- serve retail applications have also been increased. As well as being on an ever increasing number of credit card networks, prepaid smart cards and PROKEEflls can be i issued to customers. The system operator may also enter up to 300 credit card numbers of repeat customers with a specified discount for each. The Plus system also retums more credit card information and settle-up data to the PC software for easier tracking of fuel purchases. The ability to price fuel at multiple remote sites has been enhanced to ensure you're in control of your fuel. A real-time, on-site journal printer can provide hard copy backups of all transactions. A receipt printer is also available. FuelMasterf/l is a leader in the alternative fuels arena... from CNG to E85! FuelMaste'" can control and measure any liquid or gaseous fuel. Leaders in the alternative fuels field chose FuelMaster4 because of its reliability and ease of maintenance. Based on odometerlhour readings, the system calculates vehide efficiency and fuel consumption and alerts the driver and supervisor to maintenance requirements. The addition of a tank monitor interface kit permits automatic reconciliation of tank levels with FuelMaste""s declining balance. FuelMaste'" interfaces with most popu- lar tank monitors. The FuelMasterfII system may be expanded to control an almost limitless number of fueling sites. Each site consists of a master unit with up to eight satellites. FuelMaster4 is warranted for one year from date of instal- lation or fifteen months from date of shipment. Modular design and construction ensure reliability and ease of maintenance of your FuelMaste'" Fuel Manage- ment System. Site operators can quickly and easily change- out modular components, if necessary, with the assistance of FuelMastere technicians. The central controller (a PC operating on Windows 98 or higher) generates comprehensive transaction reports and invoices. Transaction data can be easily exported to most fleet main- tenance programs. If you are looking for reliability and flexibility, look no further. The purchase price is only part of what you pay for a ~-', fuel management system. Repairs and system downtime also cost you money, making reliability a key ingredient in achieving return on your investment. We encourage you to talk with FuelMastse,.e owners, particular1y those who have previously used other brands of fuel management. 'PORT ANT: OPW products should be used in compliance with applicable federal, state, provincial, .I and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ -:>_r- The OPW 61fSTOP (61'fSTOP1000 61fSTOP2000 61fSTOP305A) . 61fSTOP1 OOM 61fSTOP200M The OPW 61fSTOP AST Overfill Prevention Valve ("The Stopper") is designed to prevent overfilling of aboveground storage tanks by providing a positive shut-off during a pressurized-fill (pump-on fill) delivery. "The Stopper" threads into the fill opening and is an integral part of the fill tube. The OPW 61fSTOP is fully adjustable to allow for easy installation in new or existing aboveground tanks of various height and storage capacities. '---'13 Stopper is a single-action, complete shut-off valve. When the liquid level rises to your specific, pre-determined tank capacity, the valve mechanism is released and automatically closes with the flow of the product. Any excess product left between the valve and the fuel delivery coupler is drained into the tank through internal drain vents. The drain vents on the 61fSTOP act as an anti-siphon, by introducing air/vapor into the fill line, to help isolate the tank from a potential siphon due to a broken or leaking fill pipe. The 61fSTOP, available in either 2" or 3" full-flow models, maximizes flow rates and minimizes delivery times. The 2" 61fSTOP requires a 4" tank opening and minimum tank ullage (space from the top of the stored product to the inside top of the tank) of 8" on the 61fSTOP-1 000 Cylindrical Float model and minimum ullage of 4" on the 61fSTOP-2000 Float Arm model. The 61fSTOP-1000, with the cylindrical float, eliminates the need to position the valve to avoid tank walls or cross bracing. The 61fSTOP-2000, with the float arm allows for increased usable storage capacity in the tank and is well- suited for small capacity rectangular AST's. The 3" 61fSTOP requires a 6" tank opening and incorporates a cylindrical float requiring 8" of tank ullage space. The 3" Stopper is a high-flow unit It can accommodate flow rates over 400 gallons per minute (depending on pump capacity). The 61fSTOP-100M and -200M are anodized and compatible with 100% methanol or ethanol fuels. The OPW 61fSTOP-305A meets with the specifications of the Handbook of Aviation Fuels Properties for Aviation/Jet Fuel Compatibility (as developed by the Coordinating Research Council of the Society of Automotive Engineers). The 61fSTOP-305A is compatible with aviation fuels (including jet fuels), gasoline, gasoline-alcohol fuels, diesel, kerosene, mogas, fuel oil, motor oils (up to 60W), and anti-freeze. Table of Contents: 1. Features 2. Ordering Specifications and Dimensions 3. Replacement Parts 4_,~low Rate Charts ! OPW 61 FT Drop Tube 6. Additional Resources Features: · Simple. Easy and Quick Installation - The valve is adjusted to the proper shut-off level and threaded into the top of the tank. · Furnished Complete - A special crossbar tank-inlet adaptor is provided with each Stopper to provide for tight-fills and help prohibit open-fills. Mounting hardware, upper drop tube and 14" lower drop tube provided (longer-length drop tubes can be purchased or added). · Completely Automatic Operation - No pre-checks to perform, no resets, and no overrides to be broken or abused. · Direct or Remote-Fill Compatible - Fuel delivery couplers can be connected directly to the 61fSTOP, or steel pipe can be threaded into the top of the valve, piped to a remote location where the couplers are contained in a 211-RMOT Spill Container. · Integral Anti-Siphon Valve - Drain vents on the 61fSTOP act as an anti-siphon, by introducing air/vapor into the fill line after the valve actuates, to help isolate the tank from a potential siphon due to a broken or leaking remote-fill pipe. · 150 psi (10 bar) Pressure Rated* with Low Pressure Drop - To enable quick, safe delivery of fuel into the tank. · 25 GPM (95 Ipm) Minimum Flow Rate Required. · UL and ULC Listed - To satisfy Third Party accreditation requirements of many jurisdictions. · CARB Approved AST 01-01 *OPW does not recommend pumping pressures above 100 psi for Class 1 B fuels or remote applications and we make no warranties for products used in conjunction with the 61fSTOP. NOTE:: OPW recommends the use of the 61fSTOP with clean product only. Debris and other products such as contaminated waste oil may cause improper operation of the valve. UL Listed @ ULC Listed @ Materials: Valve body, adaptor and collar: cast aluminum Poppet: cast aluminum, hard-coated <Jsm: stainless steel Follower: brass Shaft: CRS zinc plated Bearing: sintered bronze Float: closed-cell Buna-N Nipple: 2" - 3" schedule 40 steel pipe Lower nipple: 2" - 3" schedule 40 steel pipe with Duragard@ coating ~ "'~\ Ordering Specifications and Dimensions in. em. in. em. in. em. in. em. in. 61JSTOP- 2" #000 61fSTOP- 2" Cyl. Float for 3" 7.6 10" 25.4 2" 100M Methanol . . tH'.""'m" '.v....OP.'..' ',.,,', " . -- - ',: . ;"'.', ~"', 'j: :::", ;\\ ~~-;.. -ti' . ~00 61fSTOP- 2" Float Arm for 3" 7.6 10" 200M Methanol em. in. em. 1.1 5.1 9" 22.4 31 10 nla nla 5/16" 3..& 5:4 1.... 25.4 1/2" 3.8 5- 22.4 13 5 18" 1/32" 6" 15.2 6lfstop- 3050 61fSTOP- 3" Cyl. Float for 3" 7.6 10 27 2" 5.1 8" 20.3 5 13 nla nla 305A"' Aviation or 5/8" 1/8" Methanol leeommended for E85 OPW61fStop-1000 r-" A I' .'t B L- - c , , ~ ~ TSchedule40 PIpe HIppIe '\... ltiNPT Internal 2'" Sc:hedut. 40 Pipe Nipple D I " ~ L OPW61fStop-2000 .- ~J.U1Nl'.~O ~ 0110 ~~ ii~.~ :.~ ~t) Replacement Parts 2" ~~. I ,'5,,): C04093M 4" retaining collar H12617M Floatfor 1000 (4 pieces required) Replacement Parts 3" ff ~J; ii~ ~r D02037M 6" retaining collar C04438M Float (4 pieces required for 3050) 61fStop-2" 12 ~ 10 . . a.. K . III . D: I 2 D. . . 61fStop-r Ii 71 15 IS 111: 113 1. 17$ flOW RATE.. GPII ....J.lf 10 Vi 8 Q. . i III a:: I I Q. . 4 2 o 200 I I , .JI 61 fStep-3" ." j / .J1I ~ ~ ~ ~ ~ , -' ",. --'" 251 3110 350 410 FlOW RATE .. GPM OPW 61 FT Drop Tube The OPW 61 FT Drop Tube is designed to install on the bottom of the 61fSTOP AST Overfill Prevention Valves when a lightweight, longer lower drop tube is required. Constructed of extruded aluminum, the OPW 61 FT is connected to the bottom of the 61fSTOP by a clevis and cotter pin assembly and allows for submerged filling of ASTs. Ordering Specifications and Dimensions 61 FT -0206 2" x 6' Drop Tube Kit I nstallation Instructions 61fStop 3050 & 305A.PDF I nstallation Instructions i 61fStop 1000 & 100M.PDF Installation Instructions i 61fStop 2000 & 200M.PDF ?ORT ANT: OPW products should be used in compliance with applicable federal, state, provincial, and local laws and regulations. Product selection should be based on physical specifications and limitations and compatibility with the environment and materials to be handled. OPW MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE. All illustrations and specifications in this literature are based on the latest product information available at the time of publication. OPW reserves the right to make changes at any time in prices, materials, specifications and models and to discontinue models without notice or obligation. C>PVV+ ..::....r_ OPW 199ASV Anti-Siphon Valve (199ASV-1075199ASV-2075 199ASV-3075 199ASV-4075 199ASV-1100 199ASV-2100 199ASV-3100 199ASV-4100 199ASV-1150 199ASV-2150 199ASV- 3150 199ASV-4150 199ASV-1200 199ASV-3200 199ASV-4200) The OPW 199ASV Anti-Siphon Valve is designed to help prevent siphoning of an aboveground storage tank should, a leak or break occur in the fuel supply line. The 199ASV installs on the top of an aboveground storage tank with a suction rod on the inlet and the fuel supply line (to a remote pump) on the outlet of the valve. A poppet in the valve remains normally closed, isolating the tank from c>i~honing. When the remote pump is activated, it overcomes a factory-adjusted spring set to a ~determined hydrostatic head pressure and allows flow of fuel out of the AST. An internal pressure relief valve helps absorb thermal expansion in the fuel supply line. The 199ASV is available in female NPT threads with four different factory-adjusted hydrostatic head pressure settings. Table of Contents: 1. Features 2. Ordering Specifications 3. Typical Installation 4. Additional Resources 5. Approximate Cracking Pressure Chart Features: · Factory-Adjusted Hydrostatic Head Pressure Settings- Allow for quick, safe, and easy installation on aboveground tanks. · Internal Pressure Relief Valve - Helps protect piping & fittings from damage due to thermal expansion. · Aluminum Bodies - Compatible with gasoline, diesel, kerosene, ethanol, methanol, fuel oil, and jet fuels. WARNING: Do Not Disassemble Do Not Field-Adjust Mat,rials: Aiy: hard-coated aluminum Bonnet: powder-coated aluminum Cap~ powder-coated aluminum Sprimg: stainless steel Poppet hard-coated aluminum Screw: hard-coated aluminum Poppet Seal: Buna-N (nitrile) UL Llsted @ Ordering Specifications .~~ I 199ASV-1075 3/4" .~~'$S1~I(ljlt; 199ASV-3075 3/4" 19 f. 't;rJ.f.I1..1. -~L_~,;\it - 0'-5' 19 10'-15' .. ....~...g...~,.... '.~...> "'7":'5' .' '.. .. ..'" .. -. .. '0'- .... '." <_, ...... ..... :,.,/",?'!:'>,-;;','}:,~:Y:,.<-"-- -~-- _,'~ ft.6i 199ASV-2100 1" )$~$;~~:1,~(1j. 199ASV-4100 1" 25 5'-10' e' 1.('JjJ"",'t~ 25 15'-20' 199ASV-1150 1 1/2" 38 0'-5' 1._#~1$'0 199ASV-3150 1 1/2" 38 10'-15' :tert~SV~12f)O . ~~ mUJ)fUl&~i.'~" 51 51 5'-10' A-q9ASV-4200 2" 51 15'-20' Dimensions ... 21_ Typical I nstallation 'IIO'I'E: "'~tor....... TGfulT" LoIII$t Polnt Of FUll""" Uftt Moll: ........ ..... -.y not 1lIW.... .....iGMf...... \11M ........,. ., '/ I nstaUation Instructions H13422PA-199ASV Instructions.doc Approximate Cracking Pressure Chart 0-5 1 .88 4.33 51 .96 3.85 6.20 5.35 5...1:0 3.68 8.48 101.76 7.53 12.12 10.47 10-15 5.60 12.92 155.04 1 1 .47 18.51 15.95 15--20 7.40 17.07 204.84 H5.16 24.40 21.07 I Not to Scale I SPECIFICATION I DETAIL OPTIONS A-overfill Alarm: Yes/No B-Body Connection: Male (M), Female (F) C-Float Device: Standard 2" Drop Tube Float (2") or No Float (NO) D-Face Plate: Standard (S), Metric (M), Floating Suction (I) E-Height: (Inches) F-Width: (Inches) G-Clock Diameter: (Inches) H-Shipping Weight: (Ibs) I-Body: Aluminum with 2" NPT or BSP (Metric) Connection Float: Stainless Steel; Cable: Stainless Steel The Morrison Fig. 818 Clock Gauge is used for mea- suring liquid level in aboveground storage tanks. Readout format is on a standard 12 hour clock face. Small hand represents feet and the large hand inches. Gauge can be read up to 20-30 ft. away to within 1/8". Maximum measurement capability is 12 feet. The gauge can be rotated 360. after mounting. The stan- dard float will pass through a 2" opening. Patent # 5144836 1.0. NUMBER ABC .y '.",iIP 818MEF01oo AG 818-0100 AG 818MET01oo AG 8181-0000 AG 818SS-Q100 AG 818MEB0100 AG ~-~ Face Plate Options: Standard Face Plate Floating Suction Face Plate Metric Face Plate ~ jMorrison Bros. Co. UEstablished 1855 p.o. Box 238 · Dubuque, Iowa 52004-0238 563.583.5701 (tel)' 800.553.4840' 563.583.5028 (fax) www.morbros.com Overfill Alarm & Acknowledgement Device o VEEDER-ROOT Page 1 of2 Contact Us I Site Map iSMfCH. ' Home Extranet Products Locate Distributor Locate Service FMSOnline Support Worldwide Company News & Events A TGITLS Monitoring Products ATGITLS Monitoring Consoles & Accessories Wireless Tank Gauging Tank Measurement Sump Monitoring Dispenser Pan Monitoring Double Wall Tank Monitoring Monitoring Wells Monitoring & Installation Accessories Ethernet Communications Card SlteFax Overfill Alann Direct Burial Cable Product Line Monitoring New Environmental Products Red Jacket Products Fuel Management Services Petroleum Measurement Product Brochures Overfill Alarm & Acknowledgement Device For use with TLS-350R, TLS-350, TLS-350J, TLS-300, TLS-300C, TLS-300i, TLS-300, ILS-350, and TLS-250 Systems I- Veeder-Root's TLS Overfill Alarm provides an early warning of potential tank bulk delivery overfills as required by the Federal regulations governing underground storage tanks. Wired to an alarm relay in a TLS- 350R, TLS-350, TLS-35OJ, TLS-300, TLS-300C, TLS-300i, TLS-300, ILS- 350, and TLS-250 or TLS-250i System, the alarm relay activates the TLS overfill alarm horn and light when a potential overfill is detected. All TLS systems have programmable overfill alarm limits that can be set for each tank at a location. An optional Alarm Acknowledgement Switch is also available for locations where driver Intervention is required by local codes. When the driver presses the acknowledgement button, the overfill alarm shuts off and the alarm acknowledgement light illuminates, This light will stay on until the TLS prints an inventory increase report. A built-in timer lets you adjust length of time that the audible alarm will stay on from 0 to 60 seconds, You can also adjust noise level from 78 to 103dB (at 10 feet), Features Enclosure: Painted Steel; NEMA 4; 1/2" conduit connector at bottom of alarm and at left side of acknowledgement switch Operating Temperature Range: -40 degrees to +150 degrees F Supply Voltage: 120 VAC, 50/60 Hz Alarm Unit Actuation: From TLS alarm contact Audible Alarm: Output: Adjustable "Time On" from 0 to 60 seconds Visual Alarm: Lamp Rating - 25 watt, 120 VAC; Lens - Red Polycarbonate; Flashing Rate - 75 per minute Dimensions: 11" long, 7" wide, 4" deep Alarm Acknowledgement Switch Function: Turns off alarm unit while actuating acknowledgement lamp Acknowledgement Lamp: 120 VAC, amber lens Dimensions: 7" long, 3" deep Standard Models Form No. Description 7""1.811" ., " ""- ...... ,tderrn ,. lt0095-001 Alarm Acknowledgement Switch Console Compatibility Console Series TLS-350R* 8482 TLS-350* 8470 TLS-350-] 8470 TLS-300 8485 http://www.veeder.comlpage/OverfillAlarm 9/21/2007 Overfill Alarm & Acknowledgement Device Page 2 of2 rLS- 300C '84.' TLS-250 7841 TLS-250i 8485 *Note: An I/O Combination Module (Form No. 329360-001) or a Four-Relay Output Module (Form No. 329359-001) is required for use of the Overfill Alarm and Alarm Acknowledgement Switch with the TLS-350 or TLS-350R system. Contact Us I Danaher Corp I Giibarco I Gasboy I Privacy I Legal I Site Map Copyright @ 2006 The Veeder-Root Company All rights reserved. Unauthorized duplication prohibited. http://www.veeder.comlpage/OverfillAlarm 9/21/2007 Third party certification exceeds EPA performance standards Certified performance for Inventory control and In-tank leak detection In gasolines, diesel and a wide variety of other approved fluids. ~ . Highly accurate Magnetostrictive measurement technology: · Fast, accurate leak tests. . MAG Plus Probe third-party certified to exceed US EPA performance stan- darcls for 0.1 GPH Volumetric. Tank Tightness Testing as well as 0.2 GPH monthly and continuous testing. . MAG Plus Probe is compatible with illl ILS consoles. (Software Version 11 or higher for TLS- 350/300) . Compatible with gasoline, diesel and other approved fluids, . 2:", 3" and 4" float kits available, . MAG Plus Probe is available in standard and custom lengths up to 12', Features . MAG Plus Probe provides higWy accurate trouble free performance in gasoline, diesel and a wide variety of approved fluids. . Magnetostrictive technology and five- point temperature sensing make it capable of extremely accurate inven- tory control and in-tank leak testing. Standard Models: ~....J>wsPlObe Form Nl)~ 846390-101 846390-102 846390-103 846390-104 846390-105 846390-106 846390-107 846390-108 846390-117 ..'..~ Probe Length Mag Plus Probe Fonn No. Probe Length 846390-110 10' 6" 846390-111 11 ' 846390-112 12' 846390-113 2,0 M 846390-114 2,5 M 846390-116 2,667 M 846390-115 3,OM 4' 5' 5' 4' 6' 7' 7' 6' 8' 9' 9' 6" * Float kits for the specific fuel application must be ordered separately. Kits are available for 4", 3" and 2" floats, See the Veeder-Root price list for availability, 10' Leak test performance With 4" Floats (Third Party Certified) PtObe't4tjt.1)pe P(I:)) MAG Plus 0,1 GPH 99% MAG Plus 0,2 GPH 99% MAG Plus with CSLD 0.2 GPH 99% P(FA) Test Tillie 1% 3 Hours <0.1% 2 Hours <0,1% Continuous Mag Plus Magnetostrictive probe console compatlbility** Ptube Tl.$-3$oA' TLS..aSOPlus' TLS-350. TLS450J TLS.30()i TLS.300C MAG Plus. . . . . . · = Standard Feature * A Four-Input Probe Interface Module is required for use of magnetostrictive probes with the TIS-350 or TIS-350R system. .. Software Version 11 or higher Prob.elmpl'C)veclSpeCs Standard MAG MAG Plus · With 4" floats Min. Temp. -200 C -40" C Max. Temp. +50" C +50" C Min. Fuel' 8" Min. Wat..... 0.750 0,630 3,1" For more information call o VEEDER-ROOT @ 2006 Veeder-Root Company' 125 Powder Forest Drive . Sirnsbury, CT 06070. USA Telephone: 860-651-2700 . Fax: 860-651-2719 . wwwveeder,com VR PIN 0576047-128 Rev, A VR 412006 Printed in USA