Loading...
HomeMy WebLinkAbout08-7094 CITY OFZEPHYRHILLS 5335- 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 7094 Permit #: 7094 Issued: 11/13/2007 Permit Type: NEW SINGLE FAMILY DWELLING Class of Work: 101-NEW CONST/SFR Proposed Use: SINGLE FAMILY RESIDENTIAL Sq. Feet: Est. Value: Cost: 168,636.00 Total Fees: 8,895.63 Amount Paid: '1,661.79 Date Paid: 11/13/200 Name: WINDWARD HOMES Addr: 5439 BEAUMONT CTR BLVD #1050 TAMPA, FL 33634 Phone: 813885-7744 Lie: Work Desc: NEW SINGLE FAMILY RESIDENTIAL Address: 36024 SHADY BLU ZEPHYRHILLS, FL. .~ 18 Township: Range: Lot{s): Block: Section: Book: Page: Subdivision: SILVERADO 36 ,~ Parcel Number: 04-26-21-0060-00300-0 0 Name: WINDWARD HOMES Address: 5439 BEAUMONT CTR BLVD #1050 TAMPA, FL 33634 Phone: 1794 sa FT PLYMOUTH MODEL EE MECHANICAL FEE FIRE IMPACT FEE SCHOOL IMPACT FEE-sfr/100% TRAFFIC IMPACT FEE 1% 76 . 72.14 RADON 273.00 PUBLIC SAFETY 5% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 15.88 POLICE IMPACT FEE PARK FEES SF TRAFFIC IMPACT FEE 99% 1 . 254.00 769.56 1,572.12 ~~oS :Jj - 0. '\ \Y" \l-4.~ ~::;::~ R MI C I FOOTER BOND SEWER MISC. ROUGH ELECTRIC MISC MISC. 1ST ROUGH PLUMB INSULATION WALL MISC. DUCTS INSTALLED MISC DRIVEWAY PRE-SLAB MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording our notice of commencement." ~ PERMIT OFFI NTHS WITHOUT APPROVED INSPECTIO Contractor/Homeowner: Date Received: Site: Permit Type: Approved wino comments:O City of Zephyrhills BUILDING PLAN REVIEW COMMENTS h.J,,,Au..Jou...cJ;l - S~II 0-9--\.a.d. 0 . ID{rO(07 '30 &h{)~ Irciuf'.(l."4 .- W- ~ 3{tJC>~Y s~e .... Approved withe below comments: , Denied withe below comments: 0 >fE - Il (r 14- c It 6-0 S flEeT Date Contractor and/or Homeo (Required when comments Windward Homes - Shady Bluff Lp - 36024 - Lot 18 - The Plymouth Model SQ. FEET PRICE MAIN OR LIVING: 1,794 $ 94.00 OTHER AREA UNDER ROOF: - $ 94.00 OTHER: - $ - VALUATION $ 168,636.00 FEE SHEET $ 687,00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 760.74 ELECTRICAL: $ 154,58 PLUMBING: $ 103,05 MECHANICAL: $ 72.14 SUB-TOTAL $ 1,090.50 RADON: $ 17.94 TOTAL $ 1,108.44 SEWER: $ - WATER: $ - IRRIGATION: $ - TOTAL: $ - N/A - County Jurisdiction N/A - County Jurisdiction N/A - County Jurisdiction WATER METER:I $ IRRIGATION METER $ I N/A - County Jurisdiction N/A - County Jurisdiction FIRE DEPARTMENT FEES PLANS TOTAL: $ - INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - Not Applicable Not Applicable Not Applicable Not Applicable PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273,00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 1,661,791 PARK IMPACT FEESI $ 769.56 I SIF'S: $ 4,828,00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 $ 1,588.00 $ 1,572.12 $ 15.88 TOTAL: $ 8,895.63 I ~\ \:3-~ City of Zephyrhllls Pennlt Application BuIldIng Oepcutmn Fax-813-7SG-0021 Date Received Owner's Name Owner's Address 5439 RIiun~ Fee Simple Tltleholder~' 'l Owner,P~ Hum,-, ", 0wn0r__1 , 33634 I Owner Phone Hum'-, JOB ADDRESS LOT' lIB Old)-OO~6t90 (08TAlNID !"ROM PROPIftTY TAX N011CE) SIGN 0 MOVE 0 DEMOLISH OTHER I STEEL 0 OTHER I I CiJ NEWCONSTR E3 ADDIAL.T 0 D INSTALL REPAIR PROPOSED USE . C&l 8m 0 COMM 0 TYPE OF CONSTRlIC'nON CJ BLOCK 0 FRAMe CJ DESCRIPT10H OF - I ~ Single rt, Resi&!nce BUILDING SIZE I~)l~ SQI'OOr...... n ~ <<U SUBDIVISION WORK PROPOSED o HEIGHT' BUILDING ~ 071~6 b526 kt(o 17 ,. 5+60 o GAS '0 FINISHED FLOOR ELEVAnONSI 110 . )() , I I I o I AMP SERVICE o PROGRESS ENERGY '0 ~S>- R-O-10 L ~DC WRE.C, o o o VALUAnON OF TOTAL CONSTRUCTION ELECTRiCAl PLUMBING MECHANiCAl VALUAnON OF MECHANICAL INSTALLAnON ROOFING SPECIAL. TV CJ FLOOD ZONE AREA OTHER DYES ~o ~ Addr... 3634 I A~' "I' ~p BUILDER SIGNATURE Ween..., ELECTRICIAN SIGNATURE' Addr... S & S Electric Co. ' I Q' J N j '0 CUMl!NT Lloen.., I_Ill. .a I B (2C:tj~;U')G PLUMBER SIGNATURE Addr... V1ECHANICAL SIGNATURE Addr... Address! tESIDENTlAL Weens. , COMPANY MGItT8ID VI N I Ween.. , [ )THER ;IGNATURE ~ (2) Plot ....... (2) .... of Building Pllln.: (1) aet of Inergy fIonns ' ~ tin (10) ~ da~ .,..,. eubmlttlll ct-. "equtred on...., ConettuClllon Plans, Sanlblry lIacJlltI.. & 1 dumpster AtaIoh (8) .. of IIuIdInG .....1 (1) Ht Of.'*DY rworm.. MInInun fIIn (10) wartdno day8 """1Ubrn1tt81 date. fItequ/Nd ontItIt, Construction Plane, Sanitary lIacJlltJ.. & 1 dumpster AI OOftlftIeICltII "*"*-"'__ In'" meet compliance. AtaIoh (2) .... of """'Id PI8na, u..~ i V aulWaY NCIU/I'Id for III NIW 00ftItru0ll0n. Irection.: : ~ Fill out appllcdM complUlly. Owner & ~ alan NClk of IPP/klItJon, nofMzecJ If over $2SOO, a NotIoe oIC~nt.. NqU!Nd. (Ale u..... over $8000) Agent (for the oontracliar) or Poww of Attorney (tor the 0WMt) would be eomeone with notlirlzed letter from owner aulhorJzJno ..me VER THE COUNTI!R ......In._ (Front of Application Only) Reroofs s.ww. 8erv/ce Upgrades Ale :OMMERClAL IGN PERMIT - Drlveway&-Not over Cotner If on public roadwaYS..needa ROW JIenoee (P/ofISurvey!Footllge) NOTICE OF DEED REstRICTIONS: The underalgned understands that this permit may be 8Ubjeot to ~dHcf' rwtrIctions" wh Ich may be more reatrlctlve than County regullltlone, The un~."'lgned assum.. ....ponelb.1ty for oompfJanoe WIth a applicable deed restrictions. . ny UNLICENSED CONTRACTORS AND CONTRACTOR RE8PON8I8ILITIES: If the owner he8 hnd a donnctor or contractors. to undertake work. they may be required to be IIoenMd In ~rdanoe with... and 1o?iii regulation., If the contractor IS not noenMd _ required by law. both the owner and oontractor mey be oIted for a mIIKIem.~ violation under state law. If the owner or Intended oontrIIOtoi' ... unoertllln .. to what Iloenelng requIren'Iente nwy apply for the Intended work, they are 8dv1aed to contact the puoo County Sulldlng InepeotIon DlvI8Ion-Lloenelng &eoaon lit 727-847- 8009. Furthermore, If the owner has hired a oontraotor or.oontractora. he Is advlHd to have the wOI.~.) sign portions of the .oontnlotar SIook" of thl. appllodon for WhIoh they will be rwponelble, If you, - the owner el;n a. the contractor, that may be an Indloatton that he Is not property licensed and Is not entitled to J*"YllttJng privileges In Pasco County, TRANSPORTATION IMPACTIUTlLmeS IMPACT AND R880URCa fUlCOvaRY P_: The undereIIiIneCI unCit.,..tands that Transportation Impact F....nd Reoou,..e ReooYerY P... m.y apply to the oonetruoUon of MW bulc;tJnge change of use in existing buildings. or expanelon of exleting buUdlnge.... .peolfleci'ln Paeoo County ordinance number' 89-07 and 90-07, as amended, The underalgned ".0 under8tancl8, that .uoh fen. .. may be due, wal be k:lenUfted lit the time of permitting. It Is further uncteratood that Tran.portatlon Impact F... and ReaauJ'C8 Recovery F... m.... be palel prior to receiving a "certificate of oocupanoy" or 110111 power ....... If the project does not Involv. a ~ of oooupancy or final power release, the feea must be paid prior to pennJt Iau8nce. Furthennore, If Paeoo.Qoun\y w.tM1Sewer Impact fees are due, they must be paid prior to pennlt IHuarICle In aooordanoe with applicable Paaoo County ORIlnancea, CONSTRUCTION UEN LAW (Chapter 713, FlorIda 8tatutM," amended): If valuation of work Ie $2,&00,00 or more, I certify that I, the 'applloant, have been provlcled with . oopy of the "Florida Conetruotlon LIen Law-Homeowner's Protection Guide" prepared by the FlorIcIa Department of AgrIQulture and Consumer AffUa. If the appIloant Is someone other than the "owner". I certify that I have obtained. oopy of the above deeoribed dOClUment and prom," In good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the Infonnatlon In this applloaUon Ie aoourate and that all work will be done in compliance with all applloable law. regulating oon.truallon, zoning and land cIeVeIopment, Application is hereby made to obtain a permit to do work and lnatalJation a. Indloatecl. I oertIfy that no work or InstIIIlaUon has commenced prior to Issuance of a pennlt and that all work will be perfonned to meet standards of a1118W8 regulating construction, County and City codes, zoning regulatlone. and land development regulationa In the Jurisdiction. I also certify that I understand that the regulations of other ~ent agencies may apply to the.lntended work, and that it is my responsibility to Identify what actions I must take to be In oompllance. Such agenolea InoJUcIe but... not limited to: Department of Environmental ProteotIon-Cypreaa Sayheads, Wetland Areas and EnvJronment8lly Sensitive Lands, WaterlWastewater Treatment. Southwest Florida Water Management District-Wells. Cypre.s Bayheadl, WeUanc;t Area8, Altering Watercou...... Army Corps of Englneera-Seawalls, Oock&, Navigable Waterways. Department of Health & Rehabilitative SelvloeslEnvlronmentel Health Unit-Welle. Wastewater Treatment, Septic Tanks. US Environmental protection Agency-Asbestos abatement. Federal Aviation Authortty-Runways. I understand that the following restrictions apply to the u.. of 1111: Use of flllla not allowed In Flood Zone "y- unless expressly pennltted. If the fill matertal I. to be uaecl In Flood Zone "A", It II und....tood that a drainage plan addressing a "compensatlng'volume" will be submitted at time of pennlttlng which Is preparecl by . profMalonal engineer licensed by the State of Florida, . If the fill ~ Is to be used in Flood Zone "/1(' In connection with a permitted bulding using stem wall construction. , certify that fill wBl be uaed only to fill the area within the stem wall. If fill material Is to be used In any area. I certify that use of such fill wUl not adver8eIy affect adjacent propertiea. If use of fill Is found to advenI8Iy affect adjaoent properties. the owner may be clted for violating the conditions of the building permit liaUed under the attached pennlt application, for lots le88 than one (1) acre which .. elevated by fill. an engineered drainage plan Is required, If I am the AGENT FOR THE OWNER. I promise in good faith to Inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I underlt8nd that a separate pennlt may be required for electrical work, plumbing, signs. wells. pools, air conditioning. gal, or other InataJlatIon8 not speclftcaUy Included In the application. A permit issued shall be conatNed to be a IIoense to prooeed with the work and not as authority to violate. cancel. alter, or set aside any provlalon8 of the technical codes, nor ahaIllIIuarlCe of a pennlt prevent the BuIldIng 0fftGlIII from the~eaft~r requiring a correction of errors In plans, conavuction or violations of any codes, Every permit lnued .hIIl' beCOme. invalid unless the work authorized by auch permit Is commenced within six months of permit 1asUan08. or "worK authonzed .by the permit is suspended or abandOned for a period of six (8) months after the time the work Is commenoed. An extensIon may be requested. In writing, from the Building 0fftcIaI for a period not to exceed ninety (90) day8 and wll demonstrate justifiable cause for the extension. If work 'ceases for nlnety (90) consecutive days. the job Is conaldered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CO....ENCEIIENT MAY RESULT IN YOUR PAYING lWlCE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN flilANClNG, CONSULT WITH YOUR LENnI!R OR AN ATTORNEY BRPORI! R~ORDING YOUR NOTICE OF ~. FLORIDA JURAT (F,S,117.03) . CONTRACTOR ' SUbIOftbed IInd sworn to (or ifIlnMd) bMln me.... by . WhO"'~ knOWn to me or.... pRICIuDId .. ...It\IIaIIICr.. OWNER OR AGENT . Subscribed and slNOfO to (or ifIrmed) before me this by Who is/are personally IcnOWn tD.... or hMIhaVe j)roduoecI ..ldenIIloatlon. PLOT PLAN LOT 18, BLOCK 3 SILVERADO - PHASE 1A PASCO COUNTY, FLORIDA. SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 04 ,TWP. 26 S, RNG. 21E. BEARING BASIS: SOUTHERLY LOT LINE OF LOT 18 BEING S 60'25'04" W N THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITlE SEARCH. ALSO SUBJECT TO SETBACKS. EASEMENTS AND RESTRICTIONS OF RECORD. PRELIMINARY DRAWING: THIS PLAN IS FOR PERMITllNG PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. o '" UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. LEGEND: _______ = PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE E-OO.OO = EXISTING GRADE W ....J <( U Ul. DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. TRACT 90 ZHCCL. PB 1, PAGE 55(P) '\ ~-{ '\1 ~\.,~~~ '" C00~ ",,' 0- '0 ,&. y ..:::: DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON ENGINEERING PLANS PROVIDED BY CLIENT. STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. NOTES: LOT GRADING TYPE = A PROPOSED PAD ELEVATION = 109,S' FRONT SET BACK = 20' SIDE SET BACK = 7.5' REAR SETBACK = 15' . = 10' UTILITY EASEMENT ./ LOT 19 BLOCK 3 LOT 17 BLOCK 3 TOTAL lOT AREA TOTAL SOD AREA TOTAL CONC AREA HOUSE LOT OCCUPIED =_~~Q.._SO. FT. :: -~(f42---S0. FT. --794--S0. FT. :-~g-_____SO. FT. -------_% ~ ~~ .y .' ./' OR (107.93') . " ~~ 0 ~~;-(. <=x \; O~\) ,'''\ 'l.'l.""....\\.\ -1--' 0,. \", V ,?",\ \ "- ~,~~\ ~ "1./' V 'l.'O~' \)\r~ ~~. /G~%~\)'\, ~~'f;.O\)~I'Il\ ~V S'<' <ov' V \."JO NOTE: CONC AREA NOT UNDER ROOF PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 110.10' GARAGE AREA: ELEVA TIONS REFERENCED TO NA TIONAL GEODETIC VERTICAL DATUM OF 1929. MEAN SEA LEVEL= 00.00 FT. DESCRIPTION: LOT 18, BLOCK 3, MAP OR PLAT ENTITLED "SILVERADO - PHASE lAn, AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75. OF THE PUBLIC RECORDS OF PASCO COUNI1', FLORIDA. APPARENT FLOOD HAZARD ZONE: ''X'' COMMUNITY PANEL NO, 120230 0455 D EFFECTIVE DATE: 9/30/92 LEGEND: (C)= CALCULATED DATA, (0)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, I!.= CENTERLINE, A/C= AIR CONDITIONER. B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD. CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F /C= FENC~ CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE. F1R= FOUND IRON ROD, FN&tJ= FCUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS,= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CON mOL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&C= SET NAIL & DISK, TCM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE R = RADIAL 1~ WAY 'f'( JOHN R. BEACH & ASSOCIATES, INC. SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE OLDSMAR, FLORIDA 34677 (813) 854-1276 FAX (813) 855-8370 Drown By: SMS Square Feet: 5600.00 :f: WINDWARD Checked By: JRB Scale: (~ ~ a()_ NOT VALID WITHOUT THE SIGNATURE AND Dote: PLOT PLAN 9 25 07 JBS THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER Revisions: PLOT PLAN LOT 18, BLOCK 3 SILVERADO - PHASE 1A PASCO COUNTY, FLORIDA. SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 04 ,TWP. 26 S, RNG. 21E. BEARING BASIS: SOUTHERL Y LOT LINE OF LOT 18 BEING S 60.25'04" W PRELIMINARY DRAWING: THIS PLAN IS FOR PERMITTlNG PURPOSES ONL Y, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ""0 I') THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, EASEMENTS AND RESTRICTIONS OF RECORD. UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. N LEGEND: ________ = PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE E-OO.OO = EXISTING GRADE w -' <<: u (f), DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. TRACT 90 ZHCCL, P.B. 1, PAGE 55(P) '\ ~-{ '" ~\.,~~l>' ") COU'." ",-' 0- Irj '8' Y ..:::: DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON ENGINEERING PLANS PROVIDED BY CLIENT. STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. NOTES: LOT GRADING TYPE = A PROPOSED PAD ELEVATION 109.a' mONT SET BACK = 20' SIDE SET BACK = 7.5' REAR SETBACK = 15' . = 10' UTILITY EASEMENT ./ LOT 19 BLOCK 3 LOT 17 BLOCK 3 TOTAL LOT AREA TOTAL SOD AREA TOTAL CONC AREA HOUSE LOT OCCUPIED NOTE: CONC AREA NOT UNDER ROOF = 6600.00 SO. FT. = 4~-- T _ 1042--50. F . :1m---50. ~T _ -49----50. T. ------" %~ / . . " ,/" 00<( (107.93') , ~~ \; ('"\ ~'O-(. <:~ O~'v ,,. 1-1-'" -1-' 0..\..:'0 ,?",\ \ "-~~, ,.'l '\,/" 'V 1-'O~' \),r~ ~$" /G~~ ~\)--{ '-~G~ ~~I~' ~V sY' <o\Y (JO,-<oo DESCRIPTION: LOT 18, BLOCK 3, MAP OR PLAT ENTITLED "SILVERADO - PHASE 1 A", AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 110.10' GARAGE AREA: ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL DA TUM OF 1929, MEAN SEA LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: ''X'' COMMUNITY PANEL NO, 120230 0455 D EFFECTIVE DATE: 9/30/92 LEGEND: (C)= CALCULATED DATA, (0)= DEED DATA, (1.1)= MEASURED DATA, (P)= PLAT DATA, It= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= 'CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= C ovt:R ED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F IC= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE. FIR= FOUND IRON ROD. FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE. LFE= L.OWEST FLOOR EL.EVATION, MAS.= M/\SONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R-o RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISI\, TBM= TEMPORARY BENCHMARK, U P- UTILITY POLE W F- WOOD FENCE R - RADIAL 1~ WAY )'( JOHN R. BEACH & ASSOCIATES, INC. SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE OLDSMAR, FLORIDA 34677 (813) 854-1276 FAX (813) 855-8370 Drown By: 5MS Square Feet. 5600.00 :I: WINDWARD Checked By: JRB Scale: NOT VALID WITHOUT THE SIGNATURE AND Dote: PLOT PLAN 9 25 07 JBS THE ORIGINAL RAISED SEAL. OF A FLORIDA LICENSED SURVEYOR AND MAPPER Revisions: Rece~ved: 10/ 3/07 8:35AM; OCT-~~-2007 09:24 r-U('lvt OUUA-LUU41'< SIMPSON MECHANICAL 813 558 8578 Page 2 -> WINDWARD HOMES; 813 558 8578 P.02 EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CO'DE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A prOjectNaFl1J~':...~ WW~..'''' .PLY'OU~i"i .Fi~-Builder: - WJND.WAR.O..HOMES A~dress: ~j :;>-H .. ,. \ . .. . Perm~tng Office: ~ C)~ 6e.r\'U.j ("" City, State: PermIt Number: i'Jo'i4- Owner: NE Y SMART HOME Jurisdiction Number: (p , \ (,p 0 c) Climate Zone: Central I. New construction or existing New 2. Single family Qr multi.family Single family 3. Numb.... ofunit$, ifmulti.family I 4. NumborofBcdrooms 3 5. ls this 8 wOrst case? Y ~ 6. Conditioned floor area (ft>) 1271 fiJ 7. Glass typel awl area: (Label reqd. by 13-104.4.5 if not default) I. U.factor: Description Area (or Single or Double DEFAULT) 78.(SngJe, U=I.3) 176.0 ft2 b. SHGC: (01 Clear or Tint DEFAULT) 8. Floor typeS 8. Slab.On.Qrade Edge lmulation b. N/A c. N/A 9. Wall types a. Concrc;lc. lnt Insul, El(tcrior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types L Under Allie b. Under Attic e. N/A II. Ducts a. Sup: Unc. Ret: Uoc. A.H(Sealed):<3arage Sup. R=6.0, ISo.o ft b. N/A ~.:/~~oor Are.; 0: 14 7b. (Tint) 176.0 fl' R"'O.O, I 42.0(p) ft R=4.I, 808.0 ft2 R=I1.0, 194.0 fiJ R=3B.0, 1271.0 fl' R=19.0, 99.0 fi2 12. Cooling systems a. Central Unit Cap: 28.6 kBtulhr SEER: 15.00 b. N/A c. N/A 13. Hellting systems a. Electric Heat Pump Cap; 27.8 kBtuIhr HSPF: 8.50 h. N/A c. N/A 14. Hot water sYSlems a. Electric Resistance Cap: 40.0 gallons EF: 0.92 b. N/A c. ConSc:tVation credits (HR..Heal recovery, Solar DHP.Dedicated heat pump) 15. If V AC credits (CF-Ceiling fan, CV-Cross ventilation, HF. Wholc house fan, PT.Programmlble Thermostat, MZ-C-Multizone cooling. MZ-H.Multizone healing) PT. _ OJ Total as-built points: 16702 Total base points: 17541 PASS Review of the plans and specifications eovered by this calculation indicates compliance with the Florida Energy Code. f ,~, Before construction is completed thi$ building will be inspected for compliance with Section 553.908 Florida Statutes. . I ( BUILDING OFFICIAL: '0/t DATE: V.- Receive,j: 10/ 3/07 8:36AM; 813 558 8578 -> WINDWARD HOMES; Page 3 OCT~~3-2007 09:24 I ,_" UWI v VVn.-L V V" 1"\ SIMPSON MECHANICAL 813 558 8578 P.03 EnergyGauge@ 4.5.2 SUMMER CALCULA liONS Residential Whole Building Performance Method A .. Details [!.OORESS: . . . PERMIT #: J BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM ::: Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1271.0 24,35 5571.0 1.Single,U=1.27,Tinl NW 6.0 7.7 7.0 33.43 0.69 161.0 2.Slngle, U;;1.27, Tint NE 1.0 6.0 55.0 38.88 0.97 2076.0 3.Slngle, U=1.27, Tint SE 0.5 12.7 40.0 50.79 1,00 2031.0 . 4.Single,U'"1.27, Tinl SE 0.5 13.0 16.0 50.79 1.00 812.0 5.Single,U=1.27,Tinl SE O.S 11.5 16.0 50.79 1.00 812,0 6.Single,U=1.27.Tint SE 0.5 8.7 3.0 50.79 1.00 152.0 7.Single,U;;1.27,Tlnl SW 1.0 4.0 7.0 47.30 0.89 295.0 8.Single,U=1.27.Tint SW 1.0 6.0 32.0 47.30 0,96 1467.0 " Aa-Built Total: 176,0 ~7"'~ WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacenl 194.0 0.70 135.8 1. Concrele, Int Insul, exterior 4.1 808.0 1.18 953.4 exterior 808.0 1.90 1535.2 2. Frame, Wood, Adjacent 11.0 194.0 0.70 135.8 B... Total; 1002.0 1871.0 As-Bullt Total: 1002.0 1088.2, .' . : : DOOR TYPES Area X BSPM = Points Type Ares X SPM ;::: Points Adjacent 18.0 1.60 28.8 1.Exterlor Insulated 20.0 4.80 96.0 E><<erior 20.0 4.80 96.0 2.Adjacenl Wood 18.0 2.40 43.2 Ba.. Total: 38.0 124.8 As.BuIIt Total: 38.0 138.2 CEILING TYPES Area X BSPM ::: Points Type R-Value Area X SPM X SeM :;; Points Under Attic 1271.0 2.13 2707.2 ,. Ul'lder Attic 38.0 1271.0 1.84 X 1,00 2338.6 2. Under Attic 19.0 99.0 2.82'X 1.00 279.2 Ba8e Total: 1271.0 2707.2 A8-Bullt Toeal: 1170.0 281.7.8 FLOOR TYPES Area X BSPM :: Points Type R-Value Area X SPM = Points, ' Slab 142.0(p) .31.8 -4515.6 ,. Slab-On-Grade Edge Insulation 0.0 142.0(p .31.90 -4529.8 Raised 0.0 0.00 0.0 B... Total: -4515.8 As-Bullt Total: 142.0 -4829;a INFILTRATION Area X BSPM = Points Area X SPM ;;;: Points 1271,0 14.31 18188.0 1271,0 14.31 18188.0 ., ' Ene'gyGaugeGll DCA Form aOOA-2004R EnergyGallgeQll/FlaRES'2004R FLRCS6 v4,5.2 Received: 10/ 3/07 8:36AM; 813 558 8578 -> WINDWARD HOMES; Page 4 OCT-03-2007 09:25 FO"RM 600A-2004R SIMPSON MECHANICAL 813 558 8578 P.04 EnergyGauge@ 4.5.2 SUMMER CALCULA liON'S Residential Whole Building Performance Method A - Details I ADDRESS: J , , PERMIT #: BASE AS-BUILT , Summer Base Points: 23746.4 Summer As-Built Points: 25300.5\ Total Summer X System :::: Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio MUltiplier Multiplier Multiplier Points (System . Points) (OM x DSM x AHU) (SVl 1; CiI\lI'il Ul'lit 28eOObtuh ,s~eRJeFF('S.O) DucI8:Unc(S),Une(R),Gar(AH),R6.0(INS) 25300 1.00 (1.09 x 1.150 x o.es) 0.227 0.950 6488.8 23748.4 0.3250 7717.8 25300.5 1.00 1.188 0.227 0.950 8488:8 " . ~, , : '. .. EnergyGaugeTU DCA Form 600A.2004R EnergyGauge(!)/FlaRES'2004R FI.RCSa v4.5.2 Received: 10/ 3/07 8:36AM; 813 558 8578 -> WINDWARD HOMES; Page 5 OCT-03-2007 09:25 I-OHM 600A-2004R SIMPSON MECHANICAL 813 558 8578 P.05 EnergyGauge<B> 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS;" , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1271.0 9.11 2084.0 '.Singll,U"'.27,Tint NW 6.0 7.7 7.0 15.04 0.99 104.0 2.Single. U= 1.27. Tint NE 1.0 6.0 55.0 14.B1 1.00 814.0 3.SingJe,U"'.27,Tint SE 0.5 12.7 40.0 11.25 1.00 451.0 4.Single.U;; 1.27, Tint SE 0,5 13.0 16.0 11.25 1.00 180.0 S.Single,U"1.27,Tint SE 0.5 11.5 16.0 11.25 1.00 180.0 . 8.Slngle.U=1.27,Tint se 0.5 S.7 3.0 11.ZS 1.00 33.0 7.Single,U=1.27,Tint SW 1.0 4.0 7.0 12.11 1.03 87.0 8,Single,U"1.27,Tint SW 1.0 8.0 32.0 12.11 1.01 391.0 " As-Bl.lllt Total; 176.0 2240.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Poln~ Adjacent 194.0 1.S0 349.2 1. Concrete, Int Insul, Exterior 4.1 808.0 3.31 2670.4 Exterior 808.0 2.00 1616.0 2. Frame, Wood. Adjacent 11.0 194.0 1.60 349.2 Bue Total: 1002.0 1956.2 As-Bullt Total: 1002.0 301U DOOR TYPES Area X BWPM = Points Type Area X WPM = Points : Adjacent 18.0 4.00 72.0 1.Exterior Insullllted 20.0 5.10 102.0 . Exterior 20.0 5.10 102.0 2.Adjacent Wood 18.0 5.90 106.2 BM. Total: 38.0 174.0 As.Bullt Total: 38.0 201.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1271.0 0.64 813.4 1. Under Attic 38.0 1271.0 0.55 X 1.00 699.0, 2. Under Attic 19.0 99.0 0.87 X 1.00 86.1 Base Total: 1271.0 813A As-Bullt Total: 1.370.0 78'.2 " FLOOR TYpeS Area X BWPM = Points Type R-Value Area X WPM = Pojn~., '. Slab 142.0(p) -t.9 -289.8 1. Slab-On-Grade Edge Insulation 0.0 142.0(p 2.50 355.0 Raised 0.0 0.00 0.0 " Base Total: -268.' As-Built Total: 142.0 355.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1271.0 -0.28 -355.9 1271.0 .0.28 -355.9 , ' EnergyGaug8<4> DCA Form 600A-2004R EnergyGaug~FlaRES'2004R FLRCSB v4.5.2 Received: 10/ 3/07 8:36AM; 813 558 8578 -> WINDWARD HOMES; Page 6 OCT -03-2007 09: 25 5 I MPSON MEeHAN I CAL 813 558 8578 P. 06 FORM S'OOA-2004R EnergyGauge~ 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A . Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Winter Baae Points: 4411.0 Winter As-Built Points: 6252,1' . Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Polnt$) (OM x OSM x AHU) (sys 1: Electric Heat Pump 27800 btuh .EFF(8.5) Duc:ts:Unc(S),Unc(R),Gar(AH),R8.0 6252.1 1.000 (1,078)( 1.180)( 0.95)0.402 0.950 2833.2 4411.0 0.5540 2443.7 6252.1 1.00 1.188 0.402 0.950 2833.2 EnergyGaugeT>l DCA Form 600A-20Q4R EnergyGIlIugeelFlaRES'2004R FLRCSB v4.5.2 Received: 10/ 3/07 8:36AM; 813 558 8578 -> WINDWARD HOMES; Page 7 OCT-133-213137 139: 25 SIMPSON MECHANICAL 813 558 8578 P.137 fORM 600A-2004R EnergyGauge@ 4,5.2 WATER HEATING & CODE COMPLIA.NCE 'STATUS Residential Whole Building Performance Method A - Details I ADDRESS: J . I PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2480.00 1.00 7380.0 As-Built Total: 7310,0. CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 7718 2444 7380 17541 6489 2833 7380 16702 I PASS I EnergyGiluge..... DCA Form 600A-2004R EnergyGauge~/FlaRES'2004R FLRCSB v4.5.2 Received: 10/ 3/07 8:37AM; 813 558 8578 -> WINDWARD HOMES; Page 8 OCT-03-2007 09:25 ,- '-''"'IV' UliJUI"\-"'UU6t~ SIMPSON MECHANICAL 813 558 8578 P.08 ~nergYl;augeQS1 4.0.;l Code Compliance Checklis't Residential Whole Building Performance Method A - Details I ADDRESS: J , J 6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: J o. ._ .-. . , . - - ,-- g.OM~9~ENTS SECTION --...... .~~QU1REMENl:~.F9.~ ~CI:I~~~TIC~..____ _ . h ".. .If.... , c~~~ .sP~ljo~ y'vi!!~ows & Doors 606.1,AElC.1.1 M@~!mum;.3 cff!V~q:ft. window area; .5 efm/SQ.ft. door area. .. ... ...~.._- .... ,..... I........ Exterior & Adjacent Walls 60S.1 ,ABC, 1.2.1 Clulk. gasket. weatherstrip or se.1 betw.en: windowa/doors & frames, surrounding wall: foundation & wall sole or sill plate; joints between exterior Will panels at corners; utility penetrations; between wall panels & toplbottom plates; between walla and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends .. ,. ... from and Is sealed to tile f9undBti~~.. ~~ the too olate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unl8$S backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltrl1tion barrier is installeclthat is sealed .-.-.,. ... ...- to the perimeter, D.netretions and seaJ"s, ..........~.._---- Ceilings 606.1.A8C.1.2.3 B.lweel'l walls & ceilings; penetrations of ceiling plane of top floor; around shafts. ChM", soffits, c:himneys, cabinets sealed to continUOUI aIr barrier; gape Il'l gyp board & top plate: attic access. EXCEPTION: Frame 08illng. where a continuous infiltnltion barrier is - ,.., _ n_. installed that ~ ~~~Ied.!I~ t!l..!!'p'!!!meter at DAnetrations and ..ams. Recessed Lighting Fixtures eOS.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC Or non-IC rated, installed inside a sealed box with 1/2~ clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from .--- conditioned sDace tested. -- -..--- ~Q!Y..,I19.!l~.!._. 606.1.ABC.1.2.5 Air berrier on ~~rime.te~ of. f1!l.C?i .cavity between floors. .-- ...., .... Additionallnfillration ,.qts Soe,1.ASC.1.3 Exhaust fans vented to outdoors, dampel'$; combustion space heaters comply with NFPA, have combustion aIr. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residenCH,) COMPONENTS ... " ,~~CTlON REQUIREMENTS .- .. . . - - eHECf<, ' Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3,2. Swttch or clearly marked eir ,. --...- ... brea.~~~.<eJectric) or cutoff (lias) ml.lst be Drovided. Exter;n!lL oll!.~jIHr;t.lIfJ!J.t.lr.l!P ~U!~:.... Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-eommerc;Ja1 pools must have a pump timer, Ga. spa & pool heaters must h/lve a minimum thermal '--n. - Affll'!lAnev.~f.7~~:... ,,,,'-... ,.'....._- Shower heads ~.~2.1 .-..... Water now must be restrlctedJ~ n!:l n,ore.tI).ar:! 2./5 aallons Der minuta at 80 PSIG. AIr Distribution Systems 610.1 All dl.lcts, fittings, mechanical equipment and plenum chambttS shen be mechanically attached, sealed, insulatad, and Installed in accordance with the criteria ofSecUon 610. --. - -. . " .~.. Ducts in unconditioned attics: B~ mil'!. insulation. ... ...__.. .- HVAC Controls .. , 69?- L SeDarate readilY a~i~le man'!!I! p! automatic thermostat for each sVAtem. Insulation 604.1, 602.1 Ceiling$-Min, R.19. Common walls-Frame R-11 or CBS ~-3 both sidea. Common ceiling'" noors R-l1. . . EF'lergyOauge™ DCA Form 600A-2004R EnergyGaugeQll/FlaRES'2004R FLRCSB '14.5,2 Received: 10/ 3/07 8:37AM; OCT-03-2007 09:25 SIMPSON MECHANICAL 813 558 8578 -> WINDWARD HOMES; Page 9 P.09 813 558 8578 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* ;; 86.9 The higher the seore, the more emelent the home. ENERGY SMART HOME, I , , Th. (Tinr) 176.0 ft: 12. Cooling systems II. Central Unit Cap; 28.6 kBtvlhr SEER: IS.00 1. Ncw construction or existing New 2. Single family or multi-fomily Single family 3. Number of units., ifmulti.farnily I 4. Number of Bedrooms 3 S. Is this. worst case? Yes 6. Conditioned tlOOf area (ft') 1271 ft' 7. Olass typel and area: (Label reqd. by 13-104,4.5 Ifnot default) a. U.factor: Deacription Area (or Single or Double DEFAULT) 7a.(SlliIe. U=1.3) 176.0 ftl b. SIiGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Gradc Edge Insulation b. N/A c. N/A 9. Wall types 8. CoRCr"ele. Jnt Ins\ll, Exterior b. l"rame, Wood, Adjacent c. N/A d. N/A e, N/A 10. Ceilinc types a. Under Attic b. Under Attic c;;. N/A II. Ducts a. Sup: Une. Ret: Une. AH(Sealed):Garage Sup. R=6.0, 150.0 ft b. N/A R=O.O, 142.0(p) f\. R=4.I, 808.0 fl' R=I1.0, 194.0 ft, R=3S.0, 1271.0 ft2 R=19.0, 99.0 ftl b. N/A c. N/A 13. Hcadng systems a. Elcctric Hcat Pump Cap: 27.8lcBtuIbr HSPF: 8.50 b. N/A c. N/A 14. Hot water systems a. Blectric;; Resistance Cap: 40.0 gallon.'l EF: 0.92 -.- b. N/A e. Conservation credits (HR.-Heat recoVCQ', Solar DlIP-Dedicated heat pump) 15, HV^C credits (CF.Ceiling fan, CV.Cross vlIltilation, HF.Wbolc bouse fan, PT -Programmable Thcnnottat, MZ.C.Multizone cooling, MZ-H-Multizonc belting) PT. I certify that this home has complied with the Florida Energy Efficiency Code For Building ConstnJctioD through the above energy saving features which will be installed (OT exceeded) in this home before final jnspection. Otherwise, a new EPL Display Card will be completed based on install de 1 t. . I I -J 1?J7 Builder Signature: - Date: ~cr LV / . . Address of New Homo: 3 ~ ~ CityIFLZip: , . W 'WI~ 'worE: The home's estimated energy performance sc r is only (Nailable through the FLA/RES C '"purer program. This is Mt a Building Energy Rating. '(your score is r greater (or 86101' a US EPAlDOE EnergyStar'IMdesignationj, your h~~ may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 32JI638~J492 or see the Energy Gauge web site atwwwfsec.ucfedufor information and a list of certified Ratel's. For injol'matioh about Florida's Energy Efficiency Code For Building Construction, cOntact the Department ufCummunity Affairs at 850/487./824. I Predominant glass type. FQr actUal gla.qs type and areas, see Summer &. Winter Qla.'5 OU'I!UI on.,pages 2&4. EnergyGauge~ (VersIon: FI.:RCSB \'4.5.2) Receive,d: 10/ 3/07 8: 37AM; OCT -'133-213137 139: 26 SIMPSON MECHANICAL 813 558 8578 -> WINDWARD HOMES; Page 10 P.1t3 -ttr W~~ Load Short Form Entire House SIMPSON MECHANICAL 813 558 8578 JOb: 'PLYMOUTH'.1271 S.F.... D8bt: 81312001 By: Project Information For: WINDWARD HOMES 5402 BEAUMONT CENTER BLVD. #108, TAMPA. FL Phone: (813)885-7744 Design Information Htg Outside db (OF) 40 Inside db (OF) 70 Design TO (OF) 30 Daily range Inside humidity (0/0) 50 Moisture difference (grllb) 26 CiS 92 75 17 L 50 52 Infiltration Method Constructiol"l quality Fireplaces Simplified Average o ROOM NAME Area Htg load Clg load Htg AVF CIg AVF (fP) (Btuh) (Btuh) (cfm) (cfm) FOYER 54 2708 1370 115 " FAMILY 254 3164 3325 134 154 DINING 143 2250 2314 95 101 KITCHEN 168 4470 5352 189 248 MASTER B.R. 216 3133 3799 133 118 MASTER BATH 78 2533 1234 107 57 B.R.#3 144 2209 1841 93 85 B.R.#2 167 3117 2234 132 1lU HEATING EQUIPMENT Make Lennox Trade 14HPX Series Model 14HPX-030-230* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 27800 Btuh @ 470F 25 OF 1000 efm 0.042 efmlBtuh 0.00 in H20 2 STAGE HEA HALL BATH 47 COOLING EQUIPMENT Lennox 14HPX Series 14HPX-030-230. CBX27UH-030. Make Trade Cond Coil Efficiency Sensible cooling Latent COOling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 15 SEER 22308 Btuh 6292 Btuh 28600 Btuh 100tJ cfm 0.046 cfmlBtuh 0.00 in H20 0.84 51 88 2 4 Boldll""r: V8lul$ ha"i'e bHn manUallY ttre",ClClIIl Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ~. vvngh1:Soft Rlghl-sullll RI81danllal 8.0,107 RSR29010 ~ Z;\Tvmmy ~'M6.C\WW1271PJB15,trp Cale. W8 OrIlnladon. NW 2007-0et~ 00:08:19 Palle 1 Received: 10/ 3/07 8:37AM; 813 558 8578 -> WINDWARD HOMES; Page 11 OCT -~l3-21211217 1219: 26 SIMPSON MECHANICAL 813 558 8578 P.ll Entire House 1271 23635 21557 1000 1000 Other e<:1uip loads 1110 644 Equip. @ 0.97 RSM 21623 Latent cooling 4212 TOTALS 1271 24744 25836 1000 1000 Bo/d/IUIllc Villi" h.ve ben m.nlUllly ovemddttl Printout certified by ACCA to meet all requirements of Manual J 8th Ed. &. ,^,ngt1t:soft Rlghlo$uile RCI~dCln\i., $,0.101 RSR2S918 II\.iU\ Z:\Tommy HVAC\VVW1271 PJ91S.rrp Calc. MJ8 OrlenllllCll = "lW 2007.0d-0309:08:19 P.ge 2 -rn"'T"^1 .-....... PERMIT APPLICATION DRIVEWAY PERMIT APPLICATION CONSTRUCTION WITHIN PUBUC RIGHT-Of-WAY All information ~ be filled-in completely City of Zephyrhills 5335 8th Street, Zephyrhills, FL 33542 Telephone 813.780.0000 Fax 813.780.0005 CONTRACTOR: Company: Wi nrlwrlrn HI"lI'T1I=>l"l Name: Thomas L S:pencer Contractor's License #: C8C1253910 Phone:813-885- 77 44 Cell: E-Mail: m5i'1W1gp@wi nrlwrlrnhl"ll'T1l=>l"l . I"Y'lIT1 Fax: R11-RRt;_7411 ARCHITECT IENGINEER: Name: Pearman/Berger /Carotti Address: 7.004 t;1rn nVl:>nllP "F.cst State License #: 44099/64003/64764 ,~ Firm Name: Whpt-l"lt-nnp Engi nppri nlJ g. Testil1lJ Citv:Bradenton State: FL Zip: 14?01 Phoneg41-727_1 BR Cell: Fax: . , ~IJ Desaiption of PrQject ~"'~NGTH OF DRIVEWAY [I.';!:WIDTH OF DRIVEWAY BJtW.. EXCAVATION _DEPTH _UNEAR FEET TYPE OF DRIVEWAY ---X-RESIDENTIAL DRIVEWAY _COMMERaAL DRIVEWAY _PUBUC ACCESS DRIVEWAY CONSTRUCTION MATERIAL _ASPHALT ~CONCRETE HEADWALL REOUIRED' _YES _NO CURB CUT REQUIRED _YES _NO CULVERTS NEEDED ( ) REINFORCED CONCRETE ( ) CORRUGATED MATERIAL ( ) BOX CULVERT ( ) OTHER (EXPLAIN) NOllCE TO APPLICANT: If actual work exceeds scope of this description, additional permits or drawings will be required, UTILITY LOCATIONS REQUIRED: CALL BEFORE YOU DIG: 1.800,432.4770 Page 1 of 3 PERMIT APPUCATION UTILmES LOCATE CONFIRMATION NUMBER: PROVIDE SKETCH IN THIS AREA, IF ADDITIONAL SPACE IS REQUIRED, ATTACH TO THIS APPLICATION, AFFIDAVIT: Application is hereby made to obtain a permit to do work and installations as indicated. I certify that all foregoing information is accurate and that all work will comply with all applicable codes. I understand these codes shall take precedence over all approved construction documents, and issuance of this permit is verification that I will notify the property owner of Aorida Lien Law req.,. F.S. 713. The issuance of this permit does not ensure compliance with deed restrictions and I understand that additional deed restrictions may apply to this property. All work shall comply with the current: Florida Building Code, Public Works Design Manual and FOOT Design Standards (if applicable). (Public Works Design Manual online link: www.d.zephyrhills.f1.usjpublic_works.asp) APPUCATION IS VOID UNLESS SIGNED WITH PROPER IDENTIFICATION AND WITNESSED BY A PERMIT TECHNICIAN OR NOTARY PUBUC. NOTE: The city of Zephyrhills is not responsible for maintenance or repairs of driveways. Driveways shall not alter I interfere with existing stDrmwater treatment and I or conveyance. PROPERTY OWNERS: By signing this application: I . ify that I have read and understand the owner/builder disclosure statemin~. ( I . (~ease initial) ~(~~ rcJ ~(}(rJ Applicant Print Name Applicant ~~ Permit Technician Signature (or) Notary Signature ;0110(0, Date Applicant is ( ) personally known to me or produced as identification. (type of identification) Page 2 of 3 PERMIT APPLICATION OFFICE USE ONLY '''''' . "."..-.-."--..,...,..,-,......,....,....",,.,-....--,........,........., "".. ...,.,..."_..."."...."...,,,. ...., .,. .....ip,pB111C+1l0.K$j;IlISEf.~L;y,. .. ' Concrete (min. 6") N Asphalt Base (min. 6'') Y N Asphalt (min. 1112") Y N Length (min. 19') N Width (10' min - 20' max) Existing sidewalk. New sidewalk. ADA compliant. Expansion material required. Contiguous parking pad. Triangular flare (3'W x 7'L) Visibility triangle o.k.? Side set back (3' min. R.O.W.) Plan Review Fee i( 'I ~~~;~.~~,~~"'=-""~_~Q'iIZ'f~rf1fWW:J!~'F'Wi':1m%~~-,......,-~~~-~~;,"7~~~~=>m"F"""'v~W~_~~ ~~ v~ Permit application approved by: Date: Page 3 of 3 PLOT PLAN LOT 18. Bt~OCK 3 SllVERADO - PHASE lA PASCO COUNTY. fLORIDA. SKETCH ONLY NOT A BOUNDARY SURVEY SEC~. TWP.~S, RNG.~E. BEARING BASiS: SOUTHERLY LOT LINE OF LOT 18 BEING S 80"25'O~" W . PRELIMINARY ORA WING: THIS PLAN IS FOR PERMlmNG PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. LEGEND: __ ~ PROPDSED DRIIINAGE FLOW (DO.OO) = PROPOSED GRADE E -DD.DD = EXISTlNG GRADE NOTES: LDT GRADING nPE - A PROPDSED PAD ELEVATION - 109.8' FRONT SET BACK = 20' SIDE SET BACK ~ 7.5' REAR SETBACK - 15' \. ~~"'Qt-~-\ 0':-, Ci:J-l ~. 0 .. "," V .....0 ...- -:::: TRACT 90 meeL. P.B. 1, PAGE 55(P) N THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSD SUBJECT TD SETBACKS. EASEMENTS AND RESTRICTIDNS OF RECDRO. UNDERGROUND FOOTER. STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LDCATED OR SHOWN. OD NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. DESCRIPTION NOT CONTAINING PLAT BDDK AND PAGE INDICATES THAT PLAT IS IN PRELlMINA.RY STAGE AND IS SUBJECT TO CHANGE AND/OR REVlSION. CERTAIN DATA SHOWN HEREON BASED ON ENGINEERING PLANS PROVlD.ED BY CLIENT. STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. b n ~ ~ .., (J <n. .. = 10' UTILITY EA.SEMENT = ~~g~'OO SQ. FT. :~SQ. FT. =~SQ. FT. :~~Q. FT. TOTAL LOT AREA TOTAL SOD AREA TOTAL CONC AREA HDUSE LOT OCCUPIED NOTE: CONC AREA NOT UNDER ROOF DESCRIPTION: LOT 18, BLOCK 3, MAP OR PLAT ENTITLED "SILVERADO - PHASE lA", AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75, OF THE PUBLIC RECORDS OF PASCO COUNTY. FLORIDA. PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 110.10' GARAGE AREA: ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL DATUM OF 1929. MEAN SEA LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: 'X' COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 9/30/92 LEGEND: (C)- CALCULATE[' DATA. (0)- DEED DATA, (M)- MEASURED DATA, (P)- PLAT DATA, .- CENTERLINE, A/C- AIR CONDITIONER, B/C- BACK OF CURB, C/S- CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING. CLF= CHAIN LINK FENCE. CONC= CONCRETE, COV.= COVERED, E/P- EDGE OF PAVEMENT, ESM'T= EASEMENT, F /C= FENCE CORNER, FCM- FOUND CONCRETE MONUMENT, F1P= FOUND IRON PIPE, F1R= FOUND IRON ROO, FN&O= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE. LFE= LOWEST FLOOR ELEVAT10N, MAS.= MASONRY. OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT. PRM= PERMANENT REFERENCE MONUMENT. R/W= RIGHT OF WAY, R= RADIUS. SIR-SET 1/2" IRON ROO & CAP No. ~~93, SN&O= SET N,\I1. & DISK. 18"'- TEMPORARY BENCHMARK, U P- UTILITY PO W - WOOD FENC R.... RADIAL !~ WAY)'( JOHN R. BEACH & ASSOCIATES, INC. SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE OLOSMAR, FLORIDA 3~677 (813) 85~-1276 FAX (B13) 855-8370 Drown y. Square Fee t: SMS Checked By. JRB 6600.00 % WINDWARD NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER Scale: Revisions: ,I: ~ .-:,;' !:,.i' I',f:!' ) , , .. .'J: 'f :::':i;.' ,-i ('l/L ::1.';, , , i", 1".1 r'l; ~ . i j j :,1 '1" I, '.,:1'- I /'~. ~' ! ~. '\ ~ \ ''\1-'_c:.:-/ -':;; ':,1 ,<:; ~) / ,/.t,,~ " \ / ..../ (}t, -'I ii..!; .:i' q .. ",:: ~:.:,i 0(', C i : ~" .1.,.' ,.;. :11 J)l '. '~:'ll.' .)(, :,.(. it" ')( -)(. ;.~. .'.,'0'.'_'" l: .... 1 '! llo9Y T !,':(', I' j.. ("0.... u (Y') -...j , -, 0 ~2:.' ....... u LC) -.j' 0 , ) 1.0 N oM 01 t"- C>> - I Z = ~ .. ~ ... Q.. = .Cil u = III III = ~ C'l.+> E -.:t'tIS -< 100 rtJ M M ..... tIS ..... ~ -,-4 .... "" ..= 0 - ~ ~ rJi - =lO ..= ..el ~. ""= C4 >>= ..el' Q.) !:l..~ C>> l-- N N-. ~,_._- . M ~ ....CO Cp.c C>>.... C>> 0 '"' .... 00 ~ ..el .... ~ t -,-4 .... 0 r-:l 10 ~ ~ .10 0 I () ri - ~ -., '""i ''-J ......... ~ " i A.J C !:' ~ ',-" V.... ~ \ k ~ "-' =It: Cl - III III C>> "" "Cl ~ < .... = C>> ! III C>> III III < 'ClIl "" = C>> 'E: ..cl ~ 0 II ...... ...... - CIS C,l .... III >. ..cl r:;L.. 1'\./ ........ , ~. '-l. f' ,., ......~ t...->"""! \ .J .-....... 1\ . i...__, ,.. ... \ -{ "'....J - ........: ',,"" ' ;-...... ""-... ....' C"-- " . ',. -:,;...-,-,.} v' ".. ~~~-. "- '0 ... '.S 0 f\...c-' =- .... ':::i- N """" oS , 0 .... '\ ..- Z CIS .4(~ .... .... 00 C>> C>> ;.; ~ C>> "" .... .... .... Z 00 0 v =~ 0 '~.8- ''0 Q) ] ~ .~ Q) E G -us ,.a ~ ~ Q) .... ~.; ~1 "'Cl lS €~ .~ l: :S ~ ~! ~.. .5 is: :S 5-t .~ ~ .~~ ~ii ~8 "'Cl =' : ~ =' .... "'Cl Q) Q) ~ ;~ ",0> -='0 ~~ rn Q) ~:i ::I.. - '" <'tl .. ~ ril.s ~.5 ~ Sl Z.I:l .. INNOVATIONS FOR L1YINGN This home has been professionally insulated with Advanced ThermaCube Plus@ Loosefill Insulation Nome L J}, 6Ji)t:J A\\- i Address %O)'{ i}1A Dif City -z, t7 Pf/ <-[0 1'-1 t(~,J (Job Site Address) LL~/8 I-l~/PF' Stote Zip Advanced ThermaCube Plus Loosefilllnsulation Stated R-Value is provided by installing the required number of bags per 1,000 sq. ft. at a thickness not less than the label minimum thickness. Installation of the required num- ber of bags may yield more than the specified minimum thickness and minimum sq. ft. weight. Failure by the installer to provide both the required number of bags and at least the minimum thickness will result in lower insulation R-Value. Specification for 0 NE'w Construction Retrofrt Number of bags used Estimated R-value of prE,vious insulation Area of coverage (sq. ft.) Othertype(s) of insulation in attic Thickness of insulation Depth of previous insulation ...--- /S t 'This product shows negligible settling. Unisol Vatu-Matic II machine was used to determine the cover- age information above. The machine was set up in 4th gear, with a 75% open gate and 3" hose, blOWing wool out in a 10' arc. Blanket Insulation Blanket and batt fiber glass insulation, when installed according to the manufacturers recommendations, will provide the stated R-Value. R.VALUE To obtain an insulation resistance (R) of: R-38 R-38C R-30 R-30C R-25 R-22 R-21 R-19 MINIMUM THICKNESS Installed insulation should be: 12" 10.25" 9.S" 8.25" 8,0" 6.75" 5.5" 6,25"t Nominal net weight of insulation is 351bs. Maximum Minimum Initial Minimum Settled Minimum Bags Coverage per Minimum Weight Installed Thick- Thickness in R-Value* per. 1.000 sq, ft. Bag in sq. ft. In Ibs.lsq. ft. ness in Inches' inches ' To obtain an No. of bags per Contents of each Weightih lb. per Installed insulation lnstalled.insulation insulation 1,000 sq. ft. of het bag should not sq. ft. of installed should not be jess should not be less resistance (R) of: area shall not be cover more than: insulation should than: than: less than: hot be less than: 49 25.0 40 0.878 1950 19.50 44 222 45 0.786 17.75 17.75 38 19.2 52 0.676 15.50 15.50 30 15.2 66 0.531 12.25 12.25 26 13.2 76 0.459 10.75 10.75 22 11.1 90 0.388 9.25 9.25 19 9.5 105 0.334 8.00 8.00 13 6.5 153 0,288 5,50 5.50 Do not store this product outside as the bag is not weather proof and is not UV protected from direct sun light. Looseflll insulations vary in thermal performance due to factors such as aging, mean temperature, settlement, convection. moisture absorption and installation variation. Convection in glass loosefjfllnsulation installed in open attics can reduce its thermal performance in extreme winter tem- peratures during the heating season. "'The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values. R-15 R-13 R-II 3.S" 3.5" 3.5" tR-J8 in a 5.5" cavity THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED AS SPECIFIED ABOVE: kraft unfaced foil F5-25 R-Value Thickness No.pkgs, Coverage Area Ceili",gs Floors Walls Basement Crawlspace Contractor Compony Address Phone o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o (JJgnoture) Dote Address Phone OWENS CORNING WORLD HEADQUARTERS ONE OWENS CORNING PARKWAY TOLEDO, OHIO 43659 1-800-GET-PINK