Loading...
HomeMy WebLinkAbout08-7104 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 7104 Permit #:7104 Issued: Permit Type: NEW SINGLE FAMILY DWELLING Class of Work: 1 05-NEW CONST/MUL TI 5+ UNIT Proposed Use: TOWNHOMES Sq. Feet: Est. Value: Cost: 156,322.00 Total Fees: Amount Paid: 6,138.22 Date Paid: Address: 6327 MAISIE RD #20 L ZEPHYRHILLS, FL. Township: Range: Lot(s): Block: Section: Book: Page: Subdivision: EILAND PARK TOWNHOMES Parcel Number: 03-26-21-0230-00000-1960 Name: LENNAR HOM INC Addr: 600 N. WESTSHORE BLVD STE 600 TAMPA, FL 33609 Phone: 813 769-5277 Lic: Work Desc: NEW TOWNHOME - MARTINQUE - LENNAR HOMES INC. 600 N. WESTSHORE BLVD TAMPA, FL E MECHANICAL FEE WATER CONNECTION RESIDENl FIRE IMPACT FEE SCHOOL IMPACT FEE-sfr/100% TRAFFIC IMPACT FEE 1% 68.36 RADON 641.00 WATER METER RES 3/4" 273.00 PUBLIC SAFETY 5% 1,740.00 SCHOOL IMPACT FEE-sfr/1% -9.73 FIRE PLAN REVIEW FEES FEE 16.63 SEWER CONNECTION RESIDENl 220,00 POLICE IMPACT FEE 26.35 PARK FEES TOWNHOMES 17.40 TRAFFIC IMPACT FEE 99% 93.28 FIRE INSPECTION FEES 2.010.00 254.00 769.56 -963.28 13.50 ~ 1/- I FOOTER BOND DUCTS INSULATED SEWER MISC, ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC, MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida statute 553.80 (2)(c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to yo p. perty. If you intend to obtain financing, consult with your lender or an attorney before recording yo I f commencement." ~ NATURE PERMIT OFFI IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 ( 1 City of Zephyrhills Permit Application Building Department Fax-813-780-0021 Date Received Owner's Name Owner's Address Fee Simple Titleholder Namel WEsrsNoIZE :1~I/() -t# ~aD '1/1",,/11/ JOB ADDRESS Fee Simple Titleholder Address I (p~'7 I Ell. 19 NO //4""k.. ~ PROPOSED USE 0 TYPE OF CONSTRUCTION 1&1 DESCRIPTIONOFWORK I NEw CoIVS-rtevC.17 DN - -rO(,(JNlloA'7ES BUILDING SIZE SQ FOOTAGE I '~5.3 I I HEIGHT I Dl JTt1~!:f I I J I.. r r T 111111111111'11"".'.." 11'111111111111111' II'''''' r,.,., "111"11." T' "" 1'1'111'" I r 111111111"'" T'" "'" r I' r, t., I r 1'1"111111111111111 o BUILDING 1$ ~/) / <"'..t"'I . .;/ UI.Jf,J VALUATION OF TOTAL CONSTRUCTION o ELECTRICAL 1$ .3'-1 t./ 0 AMP SERVICE ~ PROGRESS ENERGY D PLUMBING 1$ Lf 3.:(5 D MECHANICAL 1$ ~;J.~S- D GAS 0 ROOFING FINISHED FLOOR ELEVATIONS I 90 I / S' NEWCONSTR INSTALL SFR BLOCK I B D D B L"Db- 2-D RrJ/ll:> / -Z~,t1~Y~J/It.U ~ .&t..73S~ I LOT # 119ft, PARCELID#lo3-"?b-.2/-I):230- 00000-19' 0 (OBTAINED FROM PROPERTY TAX NOnCE) SIGN D MOVE 0 .tfII" /oS / E SUBDIVISION WORK PROPOSED ADDIALT REPAIR COMM FRAME o o o DEMOLISH OTHER I STEEL D OTHER I D W.R.E.C. VALUATION OF MECHANICAL INSTALLATION D I SPECIALTY 0 FLOOD ZONE AREA OTHER DYES DNO BUILDER COMPANY LE/II~ 'lit? NoN/E..s SIGNATURE REGISTERED 1(f)N I FEE CURRENT ,@N I Address LIcense # I CBC 1~1S'S7S I ELECTRICIAN ..I Be ci. ECTrt:.1 c:..... SIGNATURE IN)N I FEE CURRENT V'Y)N I Address LIcense # It:'CI:300/8S'=' PLUMBER COMPANY 1..4~vte SUllGMIf,.,J ~VRr 8/1'1? SIGNATURE REGISTERED N I FEE CURRENT I (]7:N I Address --r I'U'1If tn/I rt. LIcense # I Cpt:., o'l/?2 I MECHANICAL N6- / 9' '" C. SIGNATURE N Address License # I C /Ie 059 o(P 2. . OTHER COMPANY C. Sr~eL-IN" ~\JAI-t~ '€oo t:.. u~~ :I'Vc', SIGNATURE REGISTERED / N FEE CURRENT N Address '1211 S'J/IJ BJ.III!J -S'I*-IN6-lIIu. rt. 3'1~()'7 License # I CC-C o "5?99 / I 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach (2) Plot Plan~; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite. Construction Plans, Stormwater Plans wI Slit Fence installed. Sanitary Facilities & 1 dumpster; Site Work Permit for subdivislonsllarge projects COMMERCIAL. Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W Permit for new construction. .'~ Minimum ten (10) wOrking days after submittal date. Required onslte, Construction Plans. Storlnwater Plans w/ Slit Fence installed. Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. H**PROPERTY SURVEY required for all NEW construction. 11..11...11111111.1111111...1.111111111111111..1111..........1..1111............1111111...11111...111..1111.11......111.....111.....111........... Directions: ' Fill out application completely. Owner & Contractor sign back of application. notarized If over $2500, a Notice of Commencement Is required. (AlC upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs SeW.tl1~........,..".serylce Upgrades AlC -,_....,....,._..<..,~"'..,...."",:,..." ..~...~..~Jll><..:"- Driveways-Not ov~}~a;~Ht~;'lt oi{pi.ibn6'rbiidWl!iy~~:hEl~sROW ; ,'; ", o' '. r' ',r";:,; '\ii~;.: , . (<' .::.;-.::;~ . ~., Fences (Plol/Survey/Footage) 1 '~. . 'v ,..... '" .f.., ,_, r4.',',' ,..;,.,,~',.' ""'...........'w!>to,...~_,....."...O:N.,,,~,/j~r~...~...,;....W'l'!'l. ...~.J.~,..;.." 'C' ,:},~i~: :^,c,:1 : ~:il., ~~,;:~~:::i\;.:~(~.~~~~~_ : ,\"'..C.:'.,.i' ,., I 1',,,,,,,,'1<;\..0' ~~ \S~;j' , .'.~. ~".(~(.'::,':_;;~~'.:~,1i?~:,y.:}:::(~~,' . "'1.V~."'\; .... -~ ~'.. "'-', .,:".., ":.c'_ ~'IOI'.>"i""'.,';-,~~ ...,' ..,...~, .~,~ ,".,.o.,j'.' """,.. - NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed." restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work. they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be Identified at the time of permitting. It Is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of w9fk is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permiland that all work will be performed to meet standards of all laws regulating construction 1 County and City codes 1 zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterlWastewater Treatment. Southwest Florida Water Management District-Wells. Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to. violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the jot? is considered abandoned, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPRO TO YOUR PROPERTY. IF YOU INTEND TO 0 TAIN FINANCING, CONSULT WITH YOUR LEN ER OR Y BEFORE RECORDING YOUR NOTICE CEM NT. FLORIDA JURAT (F.S. 117,03) OWNER OR AGENT Subscribed and sworn to (or a rm /&>-rN , Zt>o'1 by ::r 0 H ~ 'I Who is/are personally known to me has/have produced as Identification. 4~~ ,-/ Commission No. /) t:> ~ 2 " Sf) 7 CONTRACTOR Subscribed and sworn to (or ffI II rll, U>D1 by .;r_ Who is/are personally known to Notary Public ~d Notary Public Commission No. l>l>.:12 '" 5"07 NameofN 'I. ~.11.. ~ Elissa~. Holleran ~ .= CommiSSIon # 00326507 -~ ~ Expires June 6, 2008 . ,$r,~' 8andtdt...,........... __ ,-1CIlI Name of Notary ty ,,,ri - ;..;.,"....... "p ~~~11I~~, Elissa M. Holleran if :W~~E Commission # 00326507 'Wf!fI.L~ Expires June 6. 2008 , -~ffln\t"'''''T..,I'''''.''''''''''1M ......"1. t MORGAN ELECTRIC LAKELAND, LLC 1120 E. OLEANDER STREET LAKELAND, FL 33801 863-688-0040 FAX: 863-683-3851 November 30h, 2007 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 To Whom It May Concern: This is to verify that Morgan Electric Company, Inc will take over the following electrical responsibilities from JBC Electric under US Home authorization and request. Permit # 7104 6327 Maisie Road Lot 196 Bldg 20 If you have any questions, please feel free to contract our office at (863) 688- 0040. Thank you for your cooperation. Sincerely, ~t \~ ~---r Tim I Morgan President, Morgan Electric Sworn to and subscribed before me thi~ay O~{~tA.D. 2007. The above is personally known to me. ~~~i'\~ o ry Public State of Florida at Larg~ 't>~.l...\l\ Q..\D My Commission Expires ~-~-DC\ ~".YPil~ SHEREE A MYERS ~ v: '" MY COMMISSION # 00471910 ~~Off\..,$ EX~IRES: Sept. 14.2009 (407} 390~15;;l 1;IOt;,:Ia Notary Service. com ................-......,.-.'". .~....._"......", ..._-~.-.~-....-. -,~.~_...... November 29,2007 City of Zephyrhills 5335 8th Street Zephyrhills, FL.33542 To Whom It May Concern, This is to verify that Morgan Electric Company, Inc will take over the following electrical responsibilities from mc Electric under US Home authorization and request. Permit# 7104 6327 Maisie Road Lot: 196 Bldg 20 If you have any questions please contact the office at (813) 890-1885, Thank you for your cooperation, Sincerely, ~ Steve R. Smith Lennar Tampa North Director of Construction Who is personally known to me. Sworn and subscribed before me this 21t'1I ,2007. ~Vlll~ Elissa M. Holleran ~f.W~ ..i Commission # 00326507 ~~~ Expires June 6, 2008 ,sr.~~ T"",," .I~_""".... "'7018 600 N. Westshore Boulevard, Suite 600, Tampa, FL 33609 · Phone: 813-769-5277 . Fox: 813-769-5278 LENNAR.CDM G2 ...."""" 111111111111111111111111111111111111111111111111111111111111 2007180247 Repl: 11388~0 Rae: 10.00 DS: 0.00 IT: 0.00 10/30/07 Dpty Clerk NOTICE OF COMMENCEMENT JED PITTMAN~ PASCO COUNTY CLERK 10/30/07 1l1:: : 2~m 1 of 1 OR BK 767'1 PG 1664 Permit No. . Property Identification No.:O.3- ~t. -.< 1- O~.30 - (!)oOo 0 - /9h 0 THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property, aJ1din ~p(:l)rdance with Section 713.13 of the Florida Statutes, the following information is provided in.this NOTICE OF COMMEN€EMENT. ,. ..., ' . . l.Descriptionofproperty(legaldescriptJon:) Lor /9fp '. ~/'-I9/11D ~f(.k 7OfAJlJI'IOMIS. Pd.&.o Pr.;I(/)~ a) Street Address: 63-'. 'J '''''lljS/i!! RDIIO ~ ", . . 2.General description of improvements: 31/11tJi-1i rAItlf/'-'j J(.~J/D~"'CC / ~O'- /Self!.,.AJ .lFNe'-~u~~ 3.0wner Information a) Name and address: Le1J/II1'11C Cbtq:'otC",.,()~# ~oo.IV. ,""cS1'"JNfJICE 8L./ll>.I-rIlMjlII.'&t. 3:11.0'1 b) Name and address of fee simple titleholder (ifother than owner) . ,. c) Interest in property 4.Contractor Information a) Name and address: J'TE.VE S'1'n 11'"/1- (,00 /l/. t4~s-r.s 110/2.6 81.1/0 S'T~ 'co I 7ANlJilI'f4 EJ. .33~oCf b) Telephone No.: (~/3) 7"9-$2.77' . Fax No. (Opt.) . ~ , . f 5.Surety Information ' , . a) Name and address: .#//1 b) Amount of Bond: N //1 . . c) Telephone No.: Fax No. (Opt.) 6.Lender a) Name and address: .AI/II Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices' or other documentS .i11a.y'beserv~d: a) Name and address: J'7el/t!SMlr)j - ,"co AI. Al43""JII(J~~ 81.111). Jr6 /.00, -rA"'~'" < #1..:/3"OC-; b) Telephone No.: ('013) 7~t:t-521'7 , . . Fax No. (Opt.) .... .,.'...> '.. 8.In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice. as proVided in Section 713.13(1)(b), Florida Statutes: a) Name and address: N /11 ,b) Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unleslIadiffetent date is specified): . WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION ,()F '.r:IiJ.lS NqTICE OF COMMENCEM~NT ARE CONSIDERED IMPROPER PA YMENTSUNI>ER CHAPTER 713, PAR'fl~:~~~WI:~713;13, FLORIDA STATUTES,-AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS T()'f~~;PJ,<>l'ERTY. A NOTICE OF CO. MM, , ENCEMENT MU. ST BE RECORDED, AND., POST.ED ON THE, JOB SITE BEE. ..'.Q.':.',.._...:,:'...'.'....T..'....:. i.. -'F.'..".'I.B..,/..,.S, T INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOuR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEM]i:NT. -) STATE OF FLORIDA COUNTY OF PASCO eror Owner's Authorized OfficerlDirectorlPll11JierlManager A(,c.).j",t!~ K. S""'eA~A/$ Print Name The foregoing instrument was acknowledged before me this /trll day of tl ,-;-()(j~;e. .20 (J7 . by. M {III'IEt. k. .:5'iEllIiNS as .MAIVAt;E t'Z. (type ofau~ority, e.g. officer, trUstee, attorney in fact) for LENN1'1te. ~ O,.e.,aOIVI/""'/ON (name of party on behalfofwh~nt was executed). PernonalIy Known ,/ OR Produced Identification _ Notary SigoaturC/~ ~c',,( ~ - Type of Identification Produced Name (print) E 1-,/ SSIl1 AI: ;..t(..(. €" 1<11r./': Verification pursuant to Section 92.525, Florida Statutes. Under penalties of perjury, I declare that I have read the foregoinglUld that the faeci stated in it are troeto the best of my knowledge e",theIIe, . ~_ . Signaturc:l of , erson.Signing Above fORM6/NOC1lVlclZQQ7 ~~.. EII_ M. Holleran :~.: ~i Commlsai.n. 00328501 · <..~fi Expires JUr?e' <VlI\a' , ,. .' , ,cuuo )r,. .......... '''''''' .,nlllt_,. --'7819 . 1 Lennar - 6327 Maisie Rd - Unit 196 SQ. FEET PRICE MAIN OR LIVING: 1,663 $ 94.00 OTHER AREA UNDER ROOF: - $ 94.00 OTHER: - $ - VALUATION $ 156,322.00 FEE SHEET $ 651.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 724.02 ELECTRICAL: $ 146.48 PLUMBING: $ 97.65 MECHANICAL: $ 68.36 SUB-TOTAL $ 1.036.50 RADON: $ 16.63 TOTAL $ 1,053.13 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER:I $ IRRIGATION METER $ 220:00 I FIRE DEPARTMENT FEES PLANS TOTAL: $ 93.28 INSPECTION TOTAL: $ 13.50 PERMIT TOTAL TOTAL: $ 106.78 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,584.261 PARK IMPACT FEESI $ 769.56 I SIF'S: $ 1,740.00 I 100.0% $ 1.740.00 1.0% $ 17.40 TOTAL: $ 1.757.40 TI F'S: $ 99% $ 1% $ (973.00 Credit due to Overcharge (963.27 Credit due to Overcharge (9.73) Credit due to Overcharge TOTAL: $ 6,138.22 I CITY 'OF ,ZEPHYRHlllS nCity of "Pure Water" Building Department 5335 Eighth Street'.Zephyrhills, Florida 33542-4312 (813) 780-0020'. Fax (813) 780-0021 W. A. "Bill" Burgess ctober 17, 2007 Director of Building Licensing & Zoning ennar Homes 00 N. Westshore Blvd, Ste 600 ampa, FI 33609 e were presented a question on whether our Transportation Impact Fee would be increased as result of Pasco County's increase which went into affect October 1, 2007. In our research it was iscovered the City has a separate charge for Townhomes in the amount of $973.00jper unit. This as inacted in 2003. The fee used for the previous buildings was $l,588.00jper unit based as a ingle family residence. Your company has been overcharged in Transportation Impacts, please ee the breakdown below. Paid Correct Fee Difference uilding 1 (5588-5598) $ 15,880.00 $ 9,730.00 $ 6,150.00 uilding 2 (5692-5701) $ 15,880.00 $ 9,730.00 $ 6,150.00 uilding 3 (5987-5996) $ 15,880.00 $ 9,730.00 $ 6,150.00 uilding 21 (Paid Impacts) $ 15,880.00 $ 9,730.00 $ 6,150.00* uilding 23 (6007-6016) $ 15,880.00 $ 9,730.00 $ 6,150.00 uilding 24 (5997-6006) $ 15,880.00 $ 9,730.00 $ 6,150.00 uilding 25 (5702-5711) $ 15,880.00 $ 9,730.00 $ 6,150.00 Totals $111,160.00 $68,110.00 $43,050.00 ue to the overcharge we will not be charging future Transportation Impacts Fees for any new own homes until the credit amount has been spent. lease be advised we are in the process of reviewing our Transportation Impact Fees and will otify you when and if any increase occurs. uilding 21 permits were transferred to Building 23. The impacts which were paid remained with uilding 21 and new impacts were paid for Building 23. When our new Transportation Impacts ees are authorized we will adjust what was paid $15,880.00 minus the correction plus the ncrease to correct the impact for this building. incerely, ,(x~ ill Burgess ulldlng Official SQ. FEET PRICE MAIN OR LIVING: i 1,(1" 0- 1,531 $ 94.00 OTHER AREA UNDER ROOF: - $ 94.00 OTHER: - $ - VALUATION $ 143,914.00 /' FEE SHEET $ 612.00 / / ADDRESS $ 30.00 / / DRIVEWAY $ 30.00 / / BUILDING: $ 684.24 ELECTRICAL: $ 137}O PLUMBING: $ 9)'.80 MECHANICAL: $ ;64.26 SUB-TOTAL $ / 978.00 RADON: $ / 15.31 TOTAL $ / 993.31 / SEWER: $ / 2,010,00 WATER: $/ 641.00 IRRIGATION: % - TOTAL: $ 2,651.00 / I WATER MET/lR: $ 220.00 I I IRRIGATION MEttER $ - I / FIRE DEPAIfTMENT FEES PLAN$ TOTAL: INSPECTIOJ.J TOTAL: PERJOIIT TOTAL / TOTAL: $ - / PUBLI~SAFETYIMPACTFEES / POLICE $ 254,00 / FIRE $ 273.00 / 5% $ 26.35 / TOTAL: $ 553.35 / / SUB-TOTAL $ 4,417.66 / I / PARK IMPACT FEESI $ 769.56 I / / SIF'S: $ 4.828.00 I 100.0% $ 4,828.00 "" 1.0% $ 48.28 TOTAL: $ 4,876.28 TI F'S: $ 1,588.00 99% $ 1.572.12 1% $ 15.88 TOTAL: $ 11,651.50 I .'- . I ) \ ' , I ! ') 0 ~ () I) n (') (} n 0 ~ 0 PERFORMANCE BUSINESS PRODUCTS, INC. 813-71N008 FAX 813-719-71l19 CITY OF ZEPHYRHILLS ZEPHYRHJLLS, FLORIDA WATER ACCT. NO, DATE i D(Z.4 len - " OWNER I RENTER LPV'\~ ~ ~ inDO ~, W~h(\<:i.Q 61(~ ~Co~ \~) ~ "3"?>l46~ SERVICE ADDREssIo3a'7 me): I')~ Rrt - 1!p^ _ On'i1- \C1lo ~WATER MAIUNG SHUT OFF SERVICE o TURN ON SERVICE uY []V" o SEWER INSTALL METER o GARBAGE READ METER o o o [g"" IN CITY CHECK METER o OUT CITY OTHER ---1- No. OF UNITS 7~- IlbY. 3/4"W,~ _ DEPOSIT AMOUNT - AMOUNT LAST BILL _ DATE _ MISC. CHARGE WORK COMPLETED BY & DATE COMPLETED ORDER TAKEN BY Retain white form in office at all times, Send pink & yellow forms to Water Service Dept. Water Service Dept. to sign yellow form & return to office. - -- i=ire Chief Keith Williams ZEPHYRHILLS FiRE DEPARTMENT 6907 Dairy Roaa. Zepnyrhills, F1- 33542 Bus (313)780-004.; Fax (3~3)780-G044 Occupancy No.: Plan No.: :1:i1 ' Business Name: . Cf nA - Business Address:. Business Phone No.: Business FaX No.: Contact: FIRE SERVICE USER FEES eemm; ~ ~ BillingAdd~ - ~~_ /-<J Billing Phone No.: 7 Billing Fax No.: Contact: ,pR-UT~~ PLAN REVIEW FEES ~Site Plan N/C ~' Multi-Family/Commercial .06 sf (Minimum Charge $25.00 o Plan Revisions DBl SPRINKLER SYSTEMS B 0 - 25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 FIRE PUMP o Per Pump FIRE ALARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS B~i, :: BOther $50 KITCHEN EXHAUST o Hood/Ducts OTHER B LP Installation per tank Fuel Tank Installation (Per Tank) o Natural Gas Installation (Per System) D Spray Booth Comments: INSPECTION FEES N/C N/C $100 $250 $500 $100 Annual 1 st Re-inspection 2nd Re-inspection 3rd Re-inspection 4th Re-Inspection (Business closed until violations corrected) SPRINKLER SYSTEMS ~ Hydro Undergrounds $45 Hydrostatic Test $65 Acceptance Test $45 ,Hydrant Flow $75 per system per system FIRE AlARM SYSTEM B System Acceptance $50 Recall Acceptance $50 OTHER ~ Fire WallISmoke Wall lP Gas . Natural Gas ~~ perwall $25 per tank $25 persyslBm $50 $50 $50 $50 $15 $45 $30 per tent $30 DBl PERMIT FEE $50 $50 $50 $50 $50 $50 $50 $50 $100 $500 $25 $100 $50 $50 $25 $50 $50 $100 150 Sprinkler Standpipes Fire Pump Hoods Fire Alarm lP Gas Natural Gas Fuel Tanks- pertank Sparklers Fire Works Camp Fire Controlled Bum Hood/Duct Place of Assembly Fire Protection Flammable Application Waste Tire Storage Generator < I<JN Generator >30 I<JN Bic-Hazard Waste Fumigation Tenting Torch PoUApplied Haz. Materials B PERMIT TOTAL~ !/~ ~~ .~ $100 Annual $50 $50 $100 Annual FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 Annual Annual Annual FALSE ALARM TOTAL I $50 ~ Tent 1 O'x1 0' or greater Fire Pump Fire Suppression System Acceptance B Exhaust Hood/Duct Re-inspection (other than annual) $50 0 Inspection scheduled DBl and cancelled less than 24 hours ""T3.0~ B Construction Insp, N/C 3f).1)1. i-=-", ~ . fo~ Emergency Vehicle ACl $50 IJ() '3.~8"", ,. PlANS TOTAL~ INSPECTION TOTAL~ q8.~ 7f, 1?'.5D~~... &4}- ~ """"" TOTAL I Om.: 1J~ff; InslJllClor. . yryI5wIl/J-P1. FbRM 600A-2004R , EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A US1531M- MARTINIQUE -1531 S.F. LIVING AREABuilder: U.s. HOMES ~32, mo..is', e Rd 1!'ZD, On;\- \'1<., Permitting Office: Q.i~ cf &P~rh, Us 'z..r.p~ rh. Us... , Fi- Permit Number: 1\0'+ j....e nno..t"" ~ Jurisdiction Number: (0 l \~O Central Project Name: Address: Cityl State: Owner: Climate Zone: ] , New construction or existing New 2. Single family or multi-family Multi-family 3. Number of units, if multi-family 4 4. Number of Bedrooms 2 5. ]s this a worst case? Yes 6. Conditioned floor area (fF) ]531 ft2 7. Glass type] and area: (Label reqd. by ] 3-] 04.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) ]27.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Grade Edge Insulation b. Raised Wood, Post or Pier c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A ] I. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft b. N/A 7b. (Clear) 127.0 ft2 R=O.O, 134.0(p) ft R=] 1.0, ]24.0ft2 R=4.I, 789.0 ft2 R=4.], ]400.0 ft2 R=30.0, 878.0 ft2 _ I ]2, Cooling systems a. Central Unit Cap: 28.8 kBtulhr SEER: 13.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 27.8 kBtulhr HSPF: 8.00 b. N/A c. N/A ]4. Hot water systems a. Electric Resistance Cap: 40,Ogallons EF: 0.92 b, N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) ]5. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) PT, Glass/Floor Area: 0.08 PASS Total as-built points: 15740 Total base points: 17780 1 Predominant glass type, For actu I glass t pe and areas. see Summer & Winter Glass output on pages 2&4, EnergyGauge@ (Version: FLRCSB v4,5,2) I hereby certify that the plans and specifications covered by this calculation are in compliance wit . a Energy Code. PREPARED BY: DATE: I hereby certify that this building, with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: 10- (\ -'0) Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553,908 Florida Statutes. FbR~ 600A-2004R EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A US1531M- MARTINIQUE -1531 S.F. LIVING AREABuilder: U.s. HOMES Permitting Office: Permit Number: Jurisdiction Number: Project Name: Address: City, State: Owner: Climate Zone: Central 1. New construction or existing New 2. Single family or multi-family Multi-family 3, Number of units, if multi-family 4 4. Number of Bedrooms 2 5, Is this a worst case? Yes 6, Conditioned floor area (fF) 1531 ft2 7. Glass type 1 and area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a, Slab-On-Grade Edge Insulation b. Raised Wood, Post or Pier c, N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e, N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft b. N/A 7b, (Clear) 127.0 ft2 R=O.O, 134.0(p) ft R= 11.0, 124.0ft2 R=4.I, 789.0 ft2 R=4.l, 1400.0 ft2 R=30.0, 878.0 ft2 12, Cooling systems a. Central Unit Cap: 28.8 kBtu/hr SEER: 13.00 b. N/A c, N/A 13. Heating systems a, Electric Heat Pump Cap: 27.8 kBtu/hr HSPF: 8.00 b, N/A c. N/A 14, Hot water systems a, Electric Resistance Cap: 40.0 gallons EF: 0.92 b, N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15, HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT-Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) PT, _ Glass/Floor Area: 0.08 PASS Total as-built points: 15740 Total base points: 17780 I hereby certify that the plans and specifications covered by this calculation are in compliance wit t . nergy Code. PREPARED BY: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes, BUILDING OFFICIAL: L ~ATE: IO-/Jr- -0- and areas, see Summer & Winter Glass output on pages 2&4, EnergyGauge@ (Version: FLRCSB v4,5.2) I hereby certify that this building, with the Florida Energy Code, OWNER/AGENT: DATE: FORM 600A-2004R EnergyGauge@ 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1531.0 24.35 6710.0 1.Single, Clear W 1.3 6,0 16,0 57.68 0,94 863.0 2.Single, Clear W 6.0 4,0 7.0 57,68 0.46 187.0 3.Single, Clear E 6.0 9.0 40,0 63,97 0,64 1642.0 4.Single, Clear W 1,3 6.0 16,0 57,68 0.94 863.0 5.Single. Clear W 1.3 10,0 16.0 57,68 0,99 912,0 6,Single, Clear E 1.3 6.0 32.0 63.97 0,94 1917.0 As-Built Total: 127.0 6384.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 1400.0 0.70 980,0 1. Concrete, Int Insul, Exterior 4.1 789,0 1.18 931,0 Exterior 789.0 1,90 1499,1 2. Concrete, Int Insul. Adjacent 4.1 1400,0 0.65 903.0 Base Total: 2189.0 2479.1 As-Built Total: 2189.0 1834.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0,0 0.00 0.0 1 ,Exterior Wood 20.0 7,20 144.0 Exterior 20.0 4,80 96,0 Base Total: 20.0 96.0 As-Built Total: 20.0 144.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 878.0 2,13 1870,1 1. Under Attic 30,0 878,0 2,13X 1.00 1870,1 Base Total: 878.0 1870.1 As-Built Total: 878.0 1870.1 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 134,O(p) -31,8 -4261,2 1. Slab-On-Grade Edge Insulation 0,0 134.0(p -31,90 -4274,6 Raised 124,0 -3,43 -425,3 2. Raised Wood, Post or Pier 11,0 124,0 1,83 226,3 Base Total: -4686.5 As-Built Total: 258.0 -4048.3 INFILTRATION Area X BSPM = Points Area X SPM = Points 1531,0 14,31 21908.6 1531.0 14,31 21908.6 EnergyGauge@ DCA Form 600A-2004R EnergyGauge@/FlaRES'2004R FLRCSB v4,5.2 FORM 600A-2004R EnergyGauge@ 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUILT Summer Base Points: 28377.3 Summer As-Built Points: 28092.5 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) , (sys 1: Central Unit 28800btuh ,SEERlEFF(13,O) Ducts:Unc(S),Con(R),lnt(AH),R6,O(INS) 28092 1.00 (1,08 x 1.150 x 0,85) 0.260 0,950 7361,6 28377.3 0.3250 9222.6 28092.5 1.00 1.061 0.260 0.950 7361.6 EnergyGauge TM DCA Form 600A-?004R EnergyGauge@/FlaRES'2004R FLRCSB v4,5,2 FORM 600A-2004R EnergyGauge@ 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1531.0 9.11 2511.0 1 ,Single. Clear W 1,3 6,0 16.0 13.25 1.01 213.0 2,Single, Clear W 6.0 4,0 7,0 13,25 1,10 102,0 3,Single, Clear E 6,0 9,0 40.0 12.37 1,10 542.0 4.Single. Clear W 1.3 6.0 16.0 13,25 1.01 213.0 5.Single, Clear W 1,3 10,0 16.0 13,25 1,00 211.0 6.Single, Clear E 1.3 6.0 32,0 12.37 1,01 401,0 As-Built Total: 127.0 1682.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 1400.0 1.80 2520.0 1, Concrete, Int Insul, Exterior 4,1 789.0 3.31 2607,6 Exterior 789.0 2.00 1578.0 2. Concrete, Int Insul, Adjacent 4,1 1400.0 2,08 2912.0 Base Total: 2189.0 4098.0 As-Built Total: 2189.0 5519.6 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0,0 0,00 0.0 1 . Exterior Wood 20,0 7.60 152.0 Exterior 20.0 5,10 102.0 Base Total: 20.0 102.0 As-Built Total: 20.0 152.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 878,0 0,64 561.9 1. Under Attic 30,0 878.0 0,64 X 1,00 561,9 Base Total: 878.0 561.9 As-Built Total: 878.0 561.9 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 134,O(p) -1,9 -254.6 1, Slab-On-Grade Edge Insulation 0.0 134.0(p 2.50 335,0 Raised 124.0 -0.20 -24.8 2. Raised Wood, Post or Pier 11.0 124,0 0.47 58.4 Base Total: -279.4 As-Built Total: 258.0 393.4 INFILTRATION Area X BWPM = Points Area X WPM = Points 1531,0 -0.28 -428,7 1531.0 -0.28 -428.7 EnergyGauge@ DCA Form 600A-2004R EnergyGauge@/FlaRES'2004R FLRCSB v4,5.2 FORM 600A-2004R , " EnergyGauge@ 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T Winter Base Points: 6564.8 Winter As-Built Points: 7880.3 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 27800 btuh ,EFF(8,O) Ducts:Unc(S).Con(R),lnt(AH),R6,O 7880,3 1,000 (1,068 x 1.160 x 0.87)0.427 0,950 3458,2 6564.8 0.5540 3636.9 7880.3 1.00 1.083 0.427 0.950 3458.2 EnergyGauge™ DCA Form 600A-2004R EnergyGauge@/FlaRES'2004R FLRCSB v4.5.2 FOR~, 600A-2004R EnergyGauge@ 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460,00 4920,0 40,0 0,92 2 1,00 2460.00 1.00 4920.0 As-Built Total: 4920.0 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 9223 3637 4920 17780 7362 3458 4920 15740 I PASS I EnergyGauge TM DCA Form 600A-2004R EnergyGauge@/FlaRES'2004R FLRCSB v4,5.2 FORM 600A-2004R EnergyGauge@ 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: , , , 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606,1,ABC.1,1 Maximum:,3 cfm/sa.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1 ,ABC.1 ,2,1 Caulk. gasket. weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & toplbottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from. and is sealed to, the foundation to the tOD Dlate, Floors 606.1 ,ABC, 1 ,2,2 Penetrations/openings >1~8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed f---.--, to the Derimeter, penetrations and seams, Ceilings 606,1 ,ABC,1 ,2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at oenetrations and seams, Recessed Lighting Fixtures 606,1,ABC,1.2.4 Type IC rated with no penetrations. sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from ----~-~ -, conditioned sDace" tested. .--- Multi-storv Houses 606.1.ABC,1,2,5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors. dampers; combustion space heaters comply with NFPA. have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612,1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker (electric) or cutoff (aas) must be Drovided. External or built-in heat traD reauired, Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pOOls must have a pump timer, Gas spa & pool heaters must have a minimum thermal efficiencv of 78%. Shower heads 612,1 Water flow must be restricted to no more than 2,5 aallons Der minute at 80 PSIG. Air Distribution Systems 610,1 All ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610, Ducts in unconditioned attics: R-6 min, insulation. HVAC Controls 607,1 SeDarate readilv accessible manual or automatic thermostat for each system, Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGauge TM DCA Form 600A-2004R EnergyGauge@/FlaRES'2004R FLRCSB v4.5,2 'ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 88.0 The higher the score, the more efficient the home. 1. New construction or existing New 2. Single family or multi-family Multi-family 3, Number of units, if multi-family 4 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft') 1531 IF 7. Glass type 1 and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 127,0 IF b. SHGC: (or Clear or Tint DEFAULT) 8. Floor types a. Slab-On-Grade Edge Insulation b. Raised Wood, Post or Pier c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d, N/A e. N/A 10. Ceiling types a. Under Attic b, N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft b. N/A 7b. (Clear) 127.0 ft2 R=O.O, I34.0(p) ft R=II.O, I24.0ft' R=4,1, 789,0 ft, R=4,I, 1400,0 ft2 R=30.0, 878.0 ft, 12, Cooling systems a, Central Unit Cap: 28.8 kBtu/hr SEER: 13.00 b, N/A c. N/A 13. Heating systems a, Electric Heat Pump Cap: 27.8 kBtu/hr HSPF: 8.00 b. N/A c. N/A 14, Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0,92 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15, HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-MuItizone heating) PT, I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above ene features which will be installed (or exceeded) in this home before fmal inspec . a new EPL Display card,wm"e IP1eted based on installed Code co . t Builder Signature: Date: f (J U L Address of New Home: CitylFL Zip: *NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP AlDOE EnergyStar™designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at wwwfsec.ucfedufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type, For actual glass type and areas, see Summer & Winter Glass outl!!lt on.,pages 2&4. EnergyGauge@(Version: FLKCStl v4.5.2) 'MAR-l~,-2007 11:25 SIMPSON MECHANICAL . -+- .Wrlghtsoft' 1118""'" .... Load Short Form Entire House SIMPSON MECHANICAL 813 558 8578 P.16 , Jiib:;. MARTINIQUE -1531 S.... ' . ~~: 11/22f.200s ~y~' t' TRH For: U.S. HOMES Design Information Htg Outside db (OF) 40 Inside db (OF) 70 Design TO (OF) 30 Dally range Inside humidity (%) Moisture difference (gr/lb) Clg 92 75 17 L 50 52 Method Construction quality Fireplaces Infiltratton:.: ' Simplified Average o , , , ROOM NAME Area Htg load Clg load HtgAVF~: :: Clg AVF (fP) (Btuh) (Btuh) (cfm) , ! (cfm) , . FOYER 68 2777 1975 11ZZ . 101 KITCHEN - NOOK 100 1834 1n2 IW 91 DINING 160 1622 378 11 ' 19 POWDER - STAIRS 131 1269 296 56, 15 LIVING 297 7432 5111 32$ 262 STAIRS - HALL 102 446 375 20 19 MASTER B.R. 239 3206 4478 141 230 MASTER BATH 58 195 173 ,9: ' 9 FLEX ROOM 146 686 571 30 29 HALL BATH 58 195 173 '9.' 9 HEATING EQUIPMENT Make Carrier Trade Base 13 Puron HP Model 25HBA330A30 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.3 HSPF 31800 Btuh @ 4rF 29 of 1000 cfm 0.044 cfmlBtuh 0.00 in H20 B.R.#2 174 COOLlN~ EQ~f~T ') : Make Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Carrier Base 13 Puron HP 25HBA330A30 FY4ANF030 13 ~SEER ,2157.0 Btuh '. :-7.630 Btuh '~92;00 Btuh '1fJO(J cfm '0.0.51 cfmlBtuh . 0100 in H20 .. :0.'84 3025 4160 133 ' 215 Bol(/l/ttlllr: V11luN Aave bOfNJ menuefly overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. A vvnghtsoft RI"h~iI8 Ruldenliel G,O.loo ~SR43813 Z:\Tommy l1VJ\eUJS1531M./e.r!1> calc"" MJe 0l'Ien1811on. W , I' 2007-Mar-1Q 12:07;24 Peat 1 : ~ ' , , , I.. ',f,' ,I :' :,r~.: MAR-19-2007 11:25 SIMPSON MECHANICAL 813 558 8578 P.17 .. Enwre House 1531 22686 19482 . 1000,' 1000 Other equip loads 1059 614 r , Equip. @ 0.97 RSM 19573 ., LatentcoolillQ 3824 : " TOTALS 1531 23745 23397 100'0 1000 ", .' .:,,1., I'" : . ". Brlldllr.JJc V11luu have "-r ITI/Inu.IJy overrlddtm Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ~, vvngh'tsoft RighI-Solie FleeIClelltlale.O.100 RSR43Bl~ ~ 2::\TonwnY""'AC\uS1!31MJ8.rrp elle= MJe OI1enlBlJon" W 2007.Mar.19 12:07;2<1 page 2 111111111111111111111I11111111111111I1111111111 "I~ 111/ 1111 210718824'7 Rept; 1138851 Ree: 18.81 DS: 0.00 IT: 1.00 18/38/07 Dpty Cl....k NOTICE OFCOMMENCE:ME~ -m93;~~~""'2 : gsco fOUN'Z, CLERK DR BK 7674 PO 16f54 PennitNo. . Property Identification No~'Q3.2t.. - .:l,'. 9i:l~ -dk)QoO-flfh 0 THE UNDERSIGNED hereby give informs you that the lmprovcment will bc made to C:e1rtaiD real prop~. ,lqI,d:bi~FC~l11c:e .with Scctlon713.13 of the Florida Statutes, the following Infol'D\ation,is providect ~ ,this NOTICE 0," COMMB~. . l.Desc:riptioDofproperty(le,alducr~'lDn:) LDr 196;'.' EU''''''D lilf..k ~"'MIS '. p8&OP4:/D:2 , a) Slrect Address: ~3.:l?' H" I$II!. 1tt>l10 . ',', , '. . 2.General description of improvements: :J'N~ ~A"""I.'t ic.6~'b~"'U: / AJoc.. / Jt:IfUIAJ ",..vn..Wdul., 3 .Owner InformatiOD . , . . a) Name Bad addreSs: L:t!A/,,,,,,,t. to""'OIt""Jo,.) - ~ 00 AI;. W4t;rJII.tt.E BUD _ "T";,M)/I". ,t:Li1~"o" b) Name and address offee simple titleho1cler (lfothetthan owner) c) Interest in property , 4.Contractor Infonnatiou ' ' . ' .'. ' , ' , a)Nameod8ddrcss: J'rE.'IES',."rll-, ~OO AI. W,eS.,..sWDtU BI."DJ'rlF'''D/"1if~'''l #'1. ,ZiS.t.tlt:1 b) 'I'elephoneNo.: (S 13) '7(;. 9-$277 ,Fax No. (Opt.) , ", , 5.S\D'Co/ Information a) Name audaddrcss: b) AmOUl1t of Bond-: .c:) Telephone No,: 6.Lendcr a) Name end addrllss: #/A, NIA Fa No. (~t.) .AI / /I Phone No. . . . 7. Identity of person within the State of Florida desipated by owner upon whom 1l000c:esor other dOCU1Jie1l18~'h,,':.ed:' a) Name and address: .J'r~"ES"", rH - ";cD .v. 1cI/!~""J"_It~ 84/1D. ".,.e ~DD _ ri4"":#fIt. Ire. ,;a!H.i!jq b) TelcphoDll No.: (813\ 7"'-"52'" " Fax No. (Opt.)" " ,':', ",' . 8.In: addition to, himselt ownerdesigDlies the following pccsoa'to receive a copy of the Lienor's NOtice, ,as proVitJ.ea'mSCletiQll 713.13(l)(b), Florida Statutes: a) NllltIe and address; N /11 ., 'b) telephone No.: ,Pa No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one'year from the date ofreQOJ'din. un1ws a.differci1t date is specified): ' ' . . . ,. , . WARN:ING TO OWNER: Am:" PAYMENTS MADE BY 11m OWNERAFl'ER TIQl: EXPIRA~~:' COMMENCE~ ARE CONSIDERED IMPROPER PAYMENTSlJNI)ER CBAfTEk 713, PAIl't;t: .', FLOlUD-A STATUTES,'AND CAN RESULT IN YOUR PAYING TWICE FOR JMJlROvEMENTS ',' A NonCE OF COMMENCEMENT MUST BE RECORDED,AND POSTED ON Tim JOB SlI'E . INSPECTION,IF yOU INTENn TO OBTAIN FINANCING, CONSULT YOUR. LENDER OR.AN /i;.;. COMMENCING WO~ OR RECORDING YOUR NOnCE OF COMMENCEMENT.' ~o= -.JJ~f2.0_~___ ',4.(,C/f"~ I. K. ..r--rGA I'e 1I/oS PrInt Name Th~ foregoing'instTumentwas lc;knOwl~dgcd bef'otemetlW /Zf'N daY9ftl(""'rJ4~1L . 20~ by' IoI,t.N"u /c- . oS '1'EII~ III$. as' . M# HA &6 H.. (type of ~ty, e,t..aftiIier, trultee, attorney fnfac::t)for '-ENNfUC. ~O~Dte"""'DN (nameofParty,onbeha1fOf~.hom' ,eDtwaslllUl',cttted )," Personally Known V OR Produced Identification _ Notary Signature ~ ,.. . . 'Type of Identification ProduCed Name (priDt) .(; z..1 SS19 .Iv. k-,,'E'.;e..;'V". V erifi~onpursuant to Section '92.525,' Florida Statutes. Under penalties of.peJjUJy, I declare that I have madthe~iDgand that .................-.............f""'___. 'A~-' . ....... . Sipdl'" f1t , ..onSIPDtI Above ~\\IV'~~.... Eti... M. "otleriln i:l1:trI. ~ Comml..,. DD326501 ,\"!,,.. Expires June C. 2ClCe' 1'I1~""',",,""''''''' __*: '. 1'tl~ItIOC,MG2OO1 ..". ..... , " , "'t t 1 I... ...~ C '" ,.r. ~ , ... ~ '...... O,..rn-~ACT(W~ ~ n Co :1. 7:f. 0:::; I~~l',ll::'.. JI:'1 ,._':~I,''''!' F)'I""r::'F:'PF']"cT'-' n',If" '00, "1:..11,# .-...1.... \.....1'....., ..,-~ I .oJ... ~.~ .._, .. .... DDR: 1591~ KING JAMES COURT ./ST: ODESSA FL 53556 PASCD COU~.lT'( ',' F"l,J)i:;;lDf.'~ AJ ,-, I I.., ~ ._, .,..... l ~.... \..' l \:' J' '.f. I' it:, iC .I. toJ Ii ~:. :"1 Pt4C7E:1 :1. elF :I. I~~~-3UE OrT':rCr::: ~ N F~ECI::::rF'T i'!UMHI::; l; O:\.ijc')~',:::.~$'~~,: OFFICE:: N~::\I,I r~ma Fi:ICI'!;:~Y Of~:: SUL:m jJJA~:),l'T~: CHEC~:: ~ :I. ~:;o.tn ONTHI~CT()H II OJ, 'l'lO;:'j '\"OTAL (.'MOL/i'n:: COMPNY ACCOllNT C~NTER B4~O - 363000 - 2 j=;'::O H ;,~ () f.JlT :l 96 t.;CNT :l t .f~ ..'::i:l. ,.~M()UNT J)E~:;(~;F: IPTI()N/PI~:!~:!1'r Df~) rl~ ,,51 ****** SOLID WASTE r~E J)R/C~:: (!)O ECEnJr:~]) '-'0 '''t { ~/ I _ BY ...."........-..-............. ........ ....n...... _._.. .__. . ..............~............ ........_. ............. ...._._....... ,.I j . ~=~ Kimley-Horn and Associates, Inc. April 9, 2008 Mr. Bill Burgess Building Official City of Zephyrhills 5335 8th Street Zephyrhills, Florida 33540 Re: Eiland Park Townhomes - Lots 191-200 Building 20 Dear Mr. Burgess: I have reviewed the As-Built Surveys of the lot grading for the above subject lots and find them in general conformance with the approved Paving, Grading & Drainage Plan. The project is located east of Massey Road and south of Eiland Boulevard. At this time the plat has not been recorded and addresses have not been assigned. If you have any questions, please do not hesitate to contact me at (813) 788-0400. Sincerely, ~01iiifIA~S'INC. WilliamJ. Ma ~r, P.E. Senior Project L.. WJM: bas Attachment ee: Lennar Homes, IDe, H:1049791oo3 - Lamar Eiland Parle Bids GradeslAgencies\CitylCorrespondoncelLot Grade Lett... - C0ZlO40908 Lots 191-2oo.dOc . TEL 813 788 0400 FAX 813 782 4978 . 5344 Ninth Street Zephyrhills, Flortda 33542 t:O ~ ~ ~t-J :::::-t;j ? ~ t; to ~ CD o ,~.. I) I I ZEPHYRHILLS COLONY CO~P ANY LANDS TRACT 77 ." " '" " <:""'d.- TRACT "C-6" WI~ON AREA n;;j i!> con !f--: >n ~I >~ '" '" 3 E (P&M) 141.00' '" roo.. '" "', "..r.J FlR 5/S" D.C. JOHNSON ., p~ ,"' i~ .q ~~ 5.2' S ,~ ,~ :9 ~ S S j:ii I~ 1':1 I~ ~ ., ~::!l 1:;'" ~~ ~.j ~ ..,f. 5.2' coZ ()1CO O<D O' ,""' CO --=0 -~ ~..., s:: " ~::;: '" ~..... ~ -. (PAW PARKING AREA) -~ S 00'21'46" W (P&~) 141.00' 18~. TRACT "C- S. .COl.l~ AREA 132.10' ~ fr~ I~ -i f'Tl :::0 :::0 )> o f'Tl It- MAISIE ROAD (24'RjW) 14-1.00' c;\.' ,i: ~~ con ~..; ~1 ~ >~ ~ D> '" o 0, Vl n ClUl MOC~ ~~~~ ~~~~ ~~~rT1 ~ "'... ~il~ oc'" "n", "'::II CD~o j; >~ "'ZI 00"' !Jl " "'"' ">0 g-<z Z <> 0>" > ,,"' ::1-<0 oc", .Z"'U;:2 o~~ " 0 ." " ;:: 1) I I I I I I " ~~ I ~~ 7 ..-/ I I ;j 8 T\ n l~ N '" ." I ;;'i I := ;;j~ >0 o~ ...0 Z :j-< o o '" ." > Z -< .... > Z o '" \'J '" ~ ~ ~. V' I ~Z SCALE: ',,, = 30' ",n z'" 9~ ~!: ",z " Z "'0 .,,> ~~ Z "'''' .,," ",0 ~~ o "'I 0", "ill -<0 pZ ;;;CD Z> ...'" '", o n"'O""'Oo ~^,)>f'Tl )>01"1(;')(.11 zCl'T'ln (;')~ ::2 ~~z~ 6~~~ '- >Z ~~M9 ~~V\""J s'" !i! 6~~~ ~O-l~ Z - '" Vl;!!;2 ~~~ ~-~ n"'o ..; ^ bZ~ o Z ZO go "'z "'0 .....; >", ^o "'> ;gf;; ~;; ",,,, ~~ "'z .... o ~ Z '" 6 Z '" > Z o ",cc IZZ 000 ~~~ '"", 00 cc' zz 00 c ..." Eg ::I..; "'''' "'.'" > '" "'", ziTi 0;:: ... .... ~~ iTir- o ~~ ul'l,"'" l>rOz U1l>-ll> OZU1, Oo~ Ou::;~ Ol>IC C::ONZ Z;>;:OO -l Ol> .-< b ::0 ...,,:;: -< ,Z U1 OI C ::90 ::0 oS: < l>1'l I'l . U1 -< rTl::::l3:-1 >-c~;!; ~M-<Vl '" '" f'TlUlOJc ~~~~ :l>2Vi-< 5" 5Vi ~~8~ .....omA ~IJ)-<("') oc ..; ..;CD> o/'Ti...,(j Zoc Vl-l,:> ~d:~ ~~a~ 8o:p"~ ;c>gUl ~~~~ ..;..; '" Z lD 0 '" U1 '" > I'l :I! '" z () g '" 18 .... lD -< > lD !ll g !Jl z 0 >- '" -< ,... -l Z ::E ..', u ,... I'~ 8 '" 0 0 lD '" !J1 z '" '" ::0 D> Z '" I: i..l ~ .... '" f"Tl