Loading...
HomeMy WebLinkAbout08-7532 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 FIRE SPRINKLER SYSTEM PERMIT 7532 Permit Number: Permit Type: Class of Work: Proposed Use: Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 732 FIRE SPRINKLER SYSTEM FIRE-SPRINKLER SYS COMMERCIAL Address: 38135 MARK T SQUA ZEPHYRHILLS, FL. Township: Range: Book: Lot{s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 02-26-21-0010-03900-0030 2,450.00 LORIDA MED CLINIC 210.00 38135 MARKET SQUARE 210.00 ZEPHYRHILLS, FL. 33540 2/22/2008 Phone: 813 780-8440 MODIFY EXISTING FIRE SPRINKLER SYSTEM H/lJ 2-~ -u8 . fet Frfl ~~~ FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." (\)~Dfn.,~ ) ONTRACTOR SIG ATURE I PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 c~~7~~;' Fire Chief Keith Williams t t .ZEPHYRHIULS FIREDEPARTMEN'[r~' 6907 Dairy Road, .Zephyrhills, FL 33542 . Bus (813)780..!0041 .FIRESERVlCEUSER FEES Fax (813)780-0044 ~I:U:CYNO':~ Business Name: . Je _ Business Address: " -: -.. """'J4? .~ Business Phone 'No.: Business Fax No.: Contact: Contractor: Billing Address: Billing Phone 'No.:' 'Billing Fax 'No.: Contact: $50 ~ Tent 10'x10' or greater RrePump Fire Supple&Sion System Acceptance B Exhaust Hood/Duct. $30 R~pection DBL (ather than annual) $50 0 Inspection scheduled DBL and cancelled less than 24 hours ~ B=:':;'''''I ~o- PLANS TOTALL).lJ INSPECTION TOTAL PLAN REVIEW FEES B Site Plan N1C MuJli-FamilylCommercial .06 sf (Minimum Charge .$25.00 o Plan Revisions DBL ~ SPRINKLER SYSTEMS 0-.25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 RRE PUMP o Per Pump $100 FIRE ALARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS B~~ :: Bother $50 KITCHEN EXHAUST o HoodIDucts OTHER B LP InsIa1Iation pertank Fuel Tank Installation (Per Tank) o Natural Gas InsIalIation (Per System) o Spray Booth Comments: PERMIT FEE $50 $50 $50 $50 $50 $50 $50 $50 $100 $500 $25 $100 $50 $50 $25 $50 $50 $100 150 INSPECTION FEES N1C N1C $100 $250 $500 prinkler Standpipes Fire Pump Hoods Fire Alarm LP Gas Natural Gas F~ Tanks- perlank $100 Annual $50 $50 $100 Annual PERMITTOTAL~ FALSE ALARM FEE 1 st Alarm N1C 2nd Alarm NlC 3rd Alarm NlC 4th Alarm $100 5th Alarm $150 6th Alarm '$200 NON COMPUANCE .$150 Annual Annual Annual FALSE ALARM TOTALc=J a (J6~'b InSijffictor: I'( y Date: Annual 1st Re-inspection 2nd Re-inspedion 3rd Re-inspection 4thRe-Inspection (Business closed until violations corrected) SPRINKLER SYSTEMS Hydro Undergrounds $45 Hydroslatic Test $65 Test $45 Hydrant FIoIN $75 FIRE AlARM SYSTEM B System Acceptance $50 Recall Acceptance $50 OTHER ~. Fire Walll5mo1ce Wall LP Gas Natural Gas Flammable AppIicaIion Waste Tire storage Generator < t<JN Generator>30 t<JN BKHiazard Waste Fumigation Tenting Torch Pot/Applied Haz. Materials $15 per~1 $25 per1ank $25 per sysII!Im $50 $50 $50 $50 $15 $45 $30 per1lont B GRAND TOTAL J ~Jl> - ~(,J~ fi1 {f1.6:?~ CITY OF ZEPHYRHILLS PERMIT APPLICATION BUILDING DEPARTMENT 5335 8TH st, Zephyrhills, FL 33542 813-780-0020 FAX: 813-780-0021 DATE RECEIVED PHONE BI""::, 180 &2-&& JOB ADDRESS 3e,l3.S fY\.PdLK.e;T :::::::s.,vfH2..€ LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION PARCEL 10 # WORK PROPSED: DNEW CONSTRUCTION o SIGN PROPOSED USE: 0 SGL FAMILY DWELLING JZfCOMMERCIAL (OBTAIN FROM PROPERTY TAX NOTICE\ o MOVE ~ALTERATION o DEMOLISH o REPAIR o INSTALL o ADDITION DMULTI-FAMILY o INDUSTRIAL 0# OF UNITS o SWIMMING POOL o MOBILE HOME o OTHER o RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK (r\0t::>/ Fl,I e:x 1~71l)b F-}~ Sfte-lnrJn.- 'S..,,~fl::}v) BUILDING SIZE SQUARE FOOTAGE HEIGHT RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. IF SIGN PERMIT ONLY (2) SETS OF ENGINEERED PLANS REQUIRED. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. o BUILDING $ 21 zf 1)"1) . DO VALUATION OF 1\ . dWJl k\fJt~ fP,p ~~v'" t. U}d- Crur- TOTAL CONSTRUCTION ~ PERMITS REQUESTED o ELECTRICAL o PLUMBING o MECHANICAL AMP SERVICE W.R.E.C. ~ ~ \f) Cl~_OCO " .." 1/7- VALUATION OF MECHANCIAL INSTALLATION v IZl' OTHER F' R ~ ~p(2., n ICl-/E'/Z. o Progress Energy o $ o GAS o ROOFING o SPECIALTY TYPE OF CONSTRUCTION: 0 BLOCK o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES 0 NO BUILDER COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** ELECTRICIAN COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** PLUMBER COMPANY SIGNATURE STATE CERT OR REGIST # ****************************************************************** MECHANICAL COMPANY SIGNATURE STATE CERT OR REGIST # ***************************************************************** FIJ'l€ SP~ll'\lu..~ OTHER -::5Z-/fl..rV{ [- 6?>MU2.-aW COMPANY -=ROl::>M F>/Z..&' SPe-Jf\1CU:::Jl.s. ) 1f'>C- SIGNATURE STATE CERT OR REGIST # <.flaeN b:JZ-ODDllSc;~ A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed restrictions" which may be more restrictive than City regulations. The undersigned assumes re~ponsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-780-0020. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign po~tions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is som~one other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Appli~ation is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for ~a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF CO NCE SIGNATURE: OWNER OR AGENT acknowledged , 20_ STATE OF FLORIDA COUNTY OF thu..c, ~i-I The foregoing instrument was acknowqedged Before me this (,f1-. day of r::t:BfWIVL, 20~ by ~l{ T' ~c......;J .....,/ (name of person acknowledged) ~ho is personally known to me, or STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _ day of by (name of person acknowledged) Dwho is personally known to me, or Dwho has produced (type and wrioD did D did not of identification) take an oath. D who has produced (type of identification) and who Ddid Oiid not take an oath -=k~~ Signature of person taking acknowledgment .f" . Signature of person taking acknowledgement Name typed, printed or stamped Name ty ~ KATHALEEN BENKE . 'nt~IRESFAuP~~ l!llIId8d Thru Notary Public UndelWriters Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 February 20, 2008 I have reviewed and approved the plans for a sprinkler system modification located at 38109 Market Sq. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Installation/modification shall compliant with the Florida Fire Prevention Code and NFP A 13, 2007 Edition. 2. Sprinkler system shall be recertified once complete. 3. FOC for this system shall be placarded so it is easily located in darkness, Reflective lettering with 4. Sprinkler cales required showing no additional demand on the existing system. Cales can be provided at sprinkler pressure test. 5. If system is not specific to this unit, if possible, flow switch shall be installed in system for this unit and wired into fire alarm to indicate that this unit has a water flow. Inspections Required 1. System shall be isolated and pressure tested. Pressure test shall be witnessed by the Fire Marshal. 2. Acceptance TestlFinal. (may be done in conjunction with fire alarm final) HILLSBOROUGH COUNTY BUSINESS TAX RENEWAL INSTRUCTIONS Chapter 205.0535 (5) Florida Statutes requires one of the following: FEDERAL EMPLOYER IDENTIFICATION NUMBER .s?-m~K6f OR SOCIAL SECURITY NUMBER 1. SIGIQ and r~urn entire fonn in enclosed envelope. Your validated Business Tax receipt will be returned to you. 2, Business Tax receipts expire midnight, September 30th. Failure to display a valid Business Tax receipt after September 30th is a violation of Hillsborough County Ordinance 95-4, as amended by 02-5. MAKE CHECK PAYABLE TO: DOUG BELDEN, TAX COLLECTOR POBox 172920 TAMPA, FL 33672-0920 2007-2008 HILLSBOROUGH COUNTY BUSINESS TAX RECEIPT EXPIRES 9-30-2008 FOLIO NO. I FACILITIES OR MACHINES 0 II ROOMS 01 I SEATS o I 1 EMPLOYEES 3111 933 oce, CODE 090,000 BUSINESS TYPE CONTRACTOR-FIRE SPRINKLERS H. WASTE TAX SURCHARGE 40.00 72,00 BUSINESS LOCA TION 2501: N 70TH SI::::::-:,:' TAM FW33619 Dee Lie Hazard Was~e Doug Beldent Hlllsbarough ~ounty lax ~oll Batch I: 1.~232 881 Vasqueztl Trans I: 2 Receipt .: 818143 Acct: 888933 Pay Code: 4286 88/87/2887 DTATCASH88 2888 $112.88 ijJS2 SUl'charge $48.8e 8351 OccupatIonal License $72.88 Ch NAME MAILING ADDRESS . ',",' ",'- .... .' ..... .... .....- ", ... ,- .--..". .. .' ", ',',' '-'- ", '-' ." ... .... -." - . . . , . . - . . . , <:. '.:.' :.", ,"-' .... ,.- .'. .-","." ",',' .... -.... ',"," '.. ... .". .. ... ........ ., .. .,.. ".' BARfWWJ~RRf THOMA$.Oa.A ~PQANf!Rt 250'1 N 70tH ST> ..,. ....... ..,.. , TAMPA FL 33619-2926 BUSINESS TAX DOUG BELDEN, TAX COLLECTOR 813-635-5200 THIS BECOMES A TAX RECEIPT WHEN VALIDA TED. HAS HEREBY PAID A PRIVILEGE TAX TO ENGAGE IN BUSINESS. PROFESSION, OR OCCUPATION SPECIFIED HEREON 4206 00093300002 000072009 000040006 STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF STATE FIRE MARSHAL TALLAHASSEE, FLORIDA CERTIFICATE OF COMPETENCY TIDS CERTIFIES THAT: JERRY T BARROW 2501 N.70TH ST. TAMPA, FL 33619- BUSINESS ORGANIZATION: RODAN FIRE SPRINKLERS, INC, CONTRACTOR I INCLUDES THE EXECUTION OF CONTRACTS REQUIRING THE ABILITY, EXPERIENCE, KNOWLEDGE, SCIENCE, AND SKILL TO INTELLIGENTL Y LAYOUT, FABRICATE, INSTALL, INSPECT, ALTER, REPAIR, OR SERVICE ALL TYPES OF FIRE PROTECTION SYSTEMS, EXCLUDING PRE-ENGINEERED SYSTEMS. Chief Financial Officer ~~ 07 01 2006 07 15 HiIlsborough Issue Date Type Class County 46848200011999 7613670001 150,00 06 30 2008 LicenselPermit Number Application # Taxes & Fees Expire Date _...nrl d.1 INC. E SPiUJ"I-- f .OOAN FIR _1 N. 70TH ST. TAMPA, FL 33619 ACOR~" CERTIFICATE OF LIABILITY INSURANCE I DATE (MM/DDIYYYY) 02/28/07 PRODUCER 1-813-229-8021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION M. E. W.iflson cOr Inc. ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 300 W. Platt St. ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Ste 200 Tampa, FL 33606 INSURERS AFFORDING COVERAGE NAIC# INSURED INSURER A: Travelers Prop Cas Ins Co 36161 Rodan Fire Sprinklers, Inc. INSURER B: Bridgefield Employers Ins Co 10701 2501 N. 70th Street INSURER C: I Tampa, FL 33619 INSURER 0: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, INSR ~~~~ P~NCY EFFECTIVE POLICY EXPIRATION TR POLICY NUMBER LIMITS A ~NERAL LIABILITY DTC00300L66AIND07 03/02/07 03/02/08 EACH OCCURRENCE $1,000,000 X OMMERCIAL GENERAL LIABILITY PREMISES lEa occureneel $ 300,000 - CLAIMS MADE 0 OCCUR f---- MED EXP (Anyone person) $5,000 '-- PERSONAL & ADV INJURY $1,000,000 - GENERAL AGGREGATE $ 2,000,000 n'LAGGREME LIMIT APnS PER: PRODUCTS - COMP/OP AGG $2,000,000 POLICY X ~~g: LOC A ~TOMOBILE LIABILITY DT8100300L66ATIL07 03/02/07 03/02/08 COMBINED SINGLE LIMIT $1,000,000 X ANY AUTO (Ea accident) - - ALL OWNED AUTOS BODILY INJURY (Per person) $ - SCHEDULED AUTOS X HIRED AUTOS - BODILY INJURY $ X NON-OWNED AUTOS (per accident) - PROPERTY DAMAGE $ (Per accident) I~RAGE LIABILITY AUTO ONLY. EA ACCIDENT $ ANY AUTO OTHER THAN EAACC $ AUTO ONLY: AGG $ A EXCESS/UMBRELLA LIABILITY DTSMCUP0300L66ATIL07 03/02/07 03/02/08 EACH OCCURRENCE $ 2,000,000 ~ OCCUR D CLAIMS MADE AGGREGATE $2,000,000 $ I~ DEDUCTIBLE $ X RETENTION $ 10,000 $ B 83030080 04/01/07 04/01/08 I WCSTATU. I !OTH- WORKERS COMPENSATION AND X TORY LIMITS ER EMPLOYERS' LIABILITY $500,000 ANY PROPRIETOR/PARTNER/EXECUTIVE X EL EACH ACCIDENT OFFICER/MEMBER EXCLUDED? E,L. DISEASE - EA EMPLOYEE $500,000 If yes, describe under $500,000 SPECIAL PROVISIONS below E,L. DISEASE. POLICY LIMIT OTHER DESCRIPTION OF OPERATIONS' LOCATIONS 'VEHICLES' EXCLUSIONS ADDED BY ENDORSEMENT' SPECIAL PROVISIONS CERTIFICATE HOLDER CANCELLATION 5335 8th Street IZePhyrhil1S, FL 33540 ACORD 25 (2001/08) adickey 5734025 USA SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL ~ DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES, AUTHORIZED REPRESENTATIVE a ~"'-~ @ACORDCORPORATION 1988 City of Zephyrhills Building Department IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER The Certificate of Insurance on the reverse side of this form does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. ACORO 25 (2001/08) Recei t # 2 0 0 8 0 04 1 7 7 Control No, 058655 f For Period Commencing JULY 1ST, 2007 and ending September 30, 2008 Total: $328.33 Dated 07/13/2007 A lication No. This Business Tax Receipt does not permit the holder to operate in violation of any City Law or Ordinance including, but not limited to, Zonina and other land use re(#Jlations, If in doubt, the holder should verify that he or she has the appropriate zoning by calling the Office of Land Development Coordination at 274-8405, This Business Tax Receipt must be conspicuously posted in place of business, Classification Description Amount 38241 993000 FIRE PROTECTION CONT I ADMIN HANDLING FEE 318.33 10.00 2008 CITY OF TAMPA TAX RECEIPT BUSINESS :~~' L '~!J~~::' ;,~ QJ.VJ:~}9~i( ....i' ~._-!-. :~:cr ~ ""i"! .r~;2~3" ~:.::~; i ",' -.."':' ';" _ - .~~ ~.~ I~ :r ~_~ .~_. S:...S t'V<;C:~:; i_ !,_ :'.':'_ i... ...-....... '-'... -.;',,, ::'"::',,-,: ;', By: CW Business Name and Address Business Name and Location RODAN FIRE SPRINKLERS INC 2501 N 70TH ST TAMPA FL 33619-2933 JERRY T BARROW 2501 N 70TH ST TAMPA FL 33619-2933 FEBRUARY 5, 2008 CITY OF ZEPHYRHILLS BUILDING DEPARTMENT 5335 8TH STREET ZEPHYRHILLS, FL 33540 RE: PERMITS Gentlemen: The following persons are authorized to secure permits for RoDan Fire sprinklers, Inc.: CRYSTAL V BARROW B600-118-83-871-0 ROBERT A. HOLCOMBE JR. H425-761-56-211-0 DUANE LECORNU L265-064-60-430-0 Enclosed is a copy of State certificate for Jerry T. Barrow and certificate of Insurance. sincerely yours, RODan Fir~~nklers, ~c. Jerry T. Barrow vice Presldent of sales JTB/jc STATE OF FLORIDA COUNTY OF HILLSBOROUGH THE FOREGOING INSTRUMENT FEBRUARY 2008, WHO IS ;~ ",,~vrU"', ' JEW!tCC:CAVAS t.~>>~,.% MY COMMISSION>> DO 500763 :.. .i,= EXPIRES: FQbruary 3,2010 ~k'f.,~ ' Bonded Thru NoIllr; Publio Undarwriter WAS ACKNOWLEDGED BEFORE ME THIS SONALLY KNOWN TO ~E. / ("" ~~ public, JEWEL C. CAVAS F RUARY 3 2010 Y commission Expires (DD500763) 5TH DAY Home Office 2501 N, 70th Street Tampa, Flonda 33619 (813) 621-1357 (813) 628-0143 Fax FED JD =It 59-1716869 E-mail: rodanfire@aol.com Sales . Design Installation . Repairs . Service Brancll Office 6650 E, Rogers Circle Boca Ratoll, Florida 33487 (561) 241-9411 Fax (561) 241-2972 E-mail: rodanfireboca@aol.com Prepared by: RoDan Fire Sprinklers, Inc, 250 I N. 70111 Street Tampa, FL 33619 P: 813-621-1357 F: 813-628-0143 Project: ROD SHELTON 38135 MARKET SQUARE ZEPHYRHILLS, FLORIDA 33540 . . . . . . . APPROVED " t ..~. Ma~"llal of Zephy. rhil1s ]V t<lrc l.J . \ vvith"comments ~i d with planes) ;PlY RODAN FIRE SPRINKlER ....................... · -tqc:o / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 .~ [ENTRAL --- Customer Service/Sales: Tel: (215) 362-0700/ (800) 523-6512 Fax: (215) 362-5385 Series TY-FRS - 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TV-FRS, 2,8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TV-FRS Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable. are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNINGn that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TV-FRS Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices, The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131. TY1231 . TY2131 . TY2231 - TY3131 - Upright 2.8K, 1/2"NPT Pendent 2.8K, 1I2"NPT Upright 4.2K,1/2"NPT Pendent 4.2K, 1/2"NPT Upright 5.6K, 1/2"NPT .JULY, 2004 .,,~~~ ~~:if"-'\2'l:~. .' . ,. ~_~_l~!:'''~iJ,'~~ .."...."-. 'll..',. . _.:'C' ..,,-:.,.. 1/ "<: ! TY3231 - TY4131 - TY4231 - Pendent 5,6K, 1/2" NPT Upright 8,OK,3/4"NPT Pendent 8.0K,3/4"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/pSP/2 (40.3 LPMlbar1/2) K = 4.2 GPM/psi1/2 (60.5 LPMlbar1/2) K = 5.6 GPM/pSP/2 (80.6 LPM/bar1/2) K = 8.0 GPM/pSP/2 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A and S TFP171 Page 2 of 8 , TFP171 . ESCUTCHEON PLATE SEATING SURFACE 7/16' (11,1 mm) NOMINAL MAKE-IN ~ STYLE 10 or 20 RECESSED ESCUTCHEON SSU* DEFLECTOR / 2-1/4' (57,2 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN J I 2-3/16' --1 (55,6 mm) 1~'NPT~ SSP DEFLECTOR * PENDENT WRENCH FLATS 2-7/8' (73,0 mm) DIA --J RECESSED PENDENT CROSS SECTION UPRIGHT 1 - Frame 2 - Button 3 - Sealing Assembly 4- Bulb 5 - Compression Screw 6 - Deflector 7 - Bushing * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) 1/2' ** NOMINAL NPT MAKE-IN ,~ STYLE 10 or 20 RECESSED ESCUTCHEON SSU* DEFLECTOR I 7/16" (11,1 mm) NOMINAL MAKE-IN J I 2-3/16" --1 (55,6 mm) 1~'NPT~ 2-3116' (55,6 mm) SSP DEFLECTOR * PENDENT WRENCH FLATS 2-7/8" (73,0 mm) DIA --J RECESSED PENDENT CROSS SECTION UPRIGHT 1 - Frame 2 - Button 3 - Sealing Assembly 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame, **Pipe thread connections per ISO 7/1 can be provided on special request, 4 - Bulb 5 - Compression Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Bulb. . . . . . . . . Compression Screw Deflector. . . . . Bushing (K=2.8) . . . .. Glass . . . . . Bronze Copper/Bronze . . . . . Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Physical Characteristics Frame. . . . . . . . . . . . . Bronze Button. . . . . . . .. Brass/Copper Sealing Assembly . . . . . . . . . . . . . ,. Beryllium Nickel wfTeflont 6 5 4 2 3 7 6* 5 4 2 3 -"" :;; E Q) '0 ~ I- '0 Q) Q; iii '0, Q) cr: E o a. ::J o +- TFP171 ESCUTCHEON PLATE SEATING SURFACE 7/16' (11,1 mm) 1/2" ** NOMINAL NPT MAKE-IN ~ STYLE 10 or 20 RECESSED ESCUTCHEON 2-3116" (55,6 mm) SSP DEFLECTOR * PENDENT WRENCH FLATS 2-7/8' (73,0 mm) DIA. j RECESSED PENDENT 1 - Frame 2 - Bullon 3 - Sealing Assembly 6 - Deflector 4 - Bulb 5 - Compression Screw Page 3 of 8 SSU* DEFLECTOR 6* 5 7/16' (11,1 mm) NOMINAL MAKE-IN , I 2.3116" ---.i (55,6 mm) '''NPT~ 4 2 3 UPRIGHT CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 1/2' (12,7 mm) 3/4" ** NOMINAL NPT MAKE-IN ~ STYLE 30 or 40 RECESSED ESCUTCHEON 2-5/16" (58,7 mm) SSP DEFLECTOR * PENDENT WRENCH FLATS 2-7/8" (73,0 mm) DIA. J RECESSED PENDENT 1 - Frame 2 - Bullon 3 - Sealing Assembly 6 - Deflector 4 - Bulb 5 - Compression Screw SSU* DEFLECTOR 6* 5 4 2 3 CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Design Criteria The Series TY-FRS Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Installation The Series TY-FRS Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler Page 4 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP, BULB NATURAL I CHROME II WHITE'" LIQUID BRASS PLATED POLYESTER 135DF/57OC Orange PENDENT 155OF/68DC Red (TY1231) 1,2,3,5 and 175OFn9OC Yellow UPRIGHT 200oF/93OC Green 2.8 (TY1131) 286OF/141OC Blue 1/2' NPT 135DF/57OC Orange RECESSED 155OF/68DC Red PENDENT (TY1231)* 175OFn9DC Yellow Figure 5 200DF/93OC Green 1,2,5 135OF/57OC Orange RECESSED 155DF/68OC Red PENDENT (TY1231)- 175OFn9OC Yellow Figure 6 200oF/93OC Green 135OF/57OC Orange PENDENT 155OF/68OC Red (TY2231 ) and 175OFn9OC Yellow UPRIGHT 200oF/93OC Green 4.2 (TY2131) 286OF/141OC Blue 1/2' 1,2 NPT 135OF/57OC Orange RECESSED 155OF/68OC Red PENDENT (TY2231 )* 175OFn9OC Yellow Figure 7 200oF/93OC Green 135OF/57OC Orange RECESSED 155OF/68OC Red PENDENT (TY2231)- 175OFn9OC Yellow Figure 8 200oF/93OC Green NOTES: 1, Listed by Underwriters Laboratories. Inc, (UL) as Quick Response Sprinklers. 2, Listed by Underwriters Laboratories, Inc, for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers, 5, Approved by the City of New York under MEA 354-01-E. 7, Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2* NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. .. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. ... Frame and Deflector only. Listings and approvals apply to color (Special Order), N/A: Not Available TABLE A LABORA TORY LISTINGS AND APPROVALS 2.8 AND 4,2 K-FACTOR SPRINKLERS held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1.6 mm) for the 1350F/57"C to 3/32 inch (2,4 mm) for the 2860F/1410C temperature ratings, A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9.5 to 19,0 Nm). A maxi- mum of 21 ft. Ibs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 TFP17,1 inch NPT sprinkler joint should'be ob- tained with a torque of 10 to 20 ft.lbs, (13,4 to 26,8 Nm). A maximum of 30 fUbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit, The Series TV -FRS Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W- Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W- Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TV-FRS Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step S. Tighten the sprinkler into the sprinkler fitting using only the W- Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TV-FRS Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling, TFP.171 Page 5 of 8 . SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME II WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135OF/57OC Orange PENDENT 155OF/68OC Red (TY3231) 1, 2, 3, 4, 5, 6, 7 1,2,3,5 and 175OF179OC Yellow UPRIGHT 200oF/93OC Green 5,6 (TY3131) 286OF/141OC Blue 1/2' NPT 135OF/57OC Orange RECESSED 155OF/68OC Red PENDENT 1,2,4,5 N/A (TY3231)* 175OF179OC Yellow Figure 9 200oF/93OC Green 135OF/57"C Orange RECESSED 155OF/68OC Red PENDENT 1, 2, 3, 4, 5 1,2,4,5 N/A (TY3231)" 175OF179OC Yellow Figure 10 200oF/93OC Green 135OF/57OC Orange PENDENT 155OF/68OC Red (TY4231) 1,2,5 and 175OF179OC Yellow 1,2,3,4,5,6,7 UPRIGHT 200oF/93OC Green 8,0 (TY4131) 286OF/141OC Blue 314' NPT 135OF/57OC Green RECESSED 155OF/68OC Orange PENDENT 1,2,4,5 N/A (TY4231)* 175OF179OC Red Figure 11 200oF/93OC Yellow 135OF/57OC Orange RECESSED 155OF/68OC Red PENDENT 1,2,3,4,5 N/A (TY4231)** 175OF179OC Yellow Figure 12 200oF/93OC Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4, Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref, No, 094a/06) as Quick Response Sprinklers. 8, Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2' NPT) or Style 30 (314' NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. ..* Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 5/Sz1/4' (15,9:t6,4 mm) 2-7/S" OIA, ;1 (73,0 mm) 2-1/4" OIA. ---l (57,2mm) / I . TFP17..1 2-7/S" OIA ;I (73,0 mm) 2-1/4' OIA ---l (57,2mm) / I CLOSURE SERIES TV-FRS 314" 19,1 mm) 1/4" (6,4 mm) 1/2z1/S" (12,h3,2 mm) -I 1-5/16" 33,3 mm) 13/16" (20,6 mm) CLOSURE SERIES TV-FRS 1-5/16' 33,3 mm) 1-1/16' (27,0 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 5/Sz1/4' (15,9:t6,4 mm) 2-7/S" OIA, ;1 (73,0 mm) 2-1/4' OIA ---l (57,2 mm) / I 314' (19,1 mm) 1/4' (6,4 mm) 1/2z1/S' (12,h3,2 mm) 2-7/S' OIA, ;1 (73,0 mm) 2-1/4" D1A, ---l (57,2 mm) / I 112" 12,7 mm) 1/4' (6,4 mm) CLOSURE 1 CLOSURE SERIES TV-FRS FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TV-FRS Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush, Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFP171 Page 7 of 8 5/601:1/4' (15,901:6,4 mm) 2-7/8" OIA. ;l (73,0 mm) 314' (19,1 mm) 2-1/4' OIA. -j 1/4' (6,4 mm) (57,2 mm) r I 11201:1/6' (12,701:3,2 mm) 2-7/8' DIA. ;l (73,0 mm) 2-1/4' DIA, -j (57,2 mm) r I 112" (12,7 mm) 114" (6,4 mm) MOUNTING PLATE CLOSURE -, 1-1/4" (31,6 mm) 314" (19,1 mm) SERIES TV-FRB 1-1/4' (31,6 mm) 1" (25,4 mm) CLOSURE FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT -t 5/801:1/4" (15,901:6,4 mm) 2-7/6' DIA'=;l (73,0 mm) 3/4' (19,1 mm) 2-1/4' DIA, ----j 1/4" (6,4 mm) (57,2 mm) .J I 1/201:1/8' (12,701:3,2 mm) 112" (12,7 mm) 1/4' (6,4 mm) MOUNTING PLATE CLOSURE SERIES TV-FRB 1-5116' (33,3 mm) 13116" (20,6 mm) 1-5/16' (33,3 mm) 1-1/16' (27,0 mm) CLOSURE SERIES TV-FRB FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS ~D WRENCH RECESS (END '8' USED FOR 3/4' NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 13 W- TYPE 6 SPRINKLER WRENCH local requirements and/or national codes. FIGURE 14 W- TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 PIN 57 - XXX - X - XXX I I I MODEUSIN 330 2,8K UPRIGHT (1/2'NPT) TY1131 331 2,8K PENDENT (1/2'NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2'NPT) TY3231 390 8.0K UPRIGHT (314'NPT) TY4131 391 8,OK PENDENT (314'NPT) TY 4231 TEMPERATURE RATING SPRINKLER 135 135OF/57OC NATURAL BRASS 155 155OF/68OC WHITE POLYESTER 175 175OFn9OC WHITE (RAL9010)' 200 200oF/93OC CHROME PLATED 286 2860F/141 oC 4 3 9 7 LEAD COATED 'TFP17:t , Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, andlor the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option, Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- E!2SE... Ordering Procedure (,\)MtlSrM:iylJlan local distributor for avail- ablIl!V.indicate the full product name, Aefer to the Price List for complete listing of Part Numbers, Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), PIN (specify). 1/2' (15 mm) Style 10 Chrome Plated, . . . , , , , . . .. PIN 56-701-9-010 While Coated. . . ' , . , , , , , " PIN 56-701-4-010 White AAl9010'., ,.. ", , ,. PIN 56-701-3-010 Brass Plated,.,.. ..",. ,., PIN 56-701-2-010 1/2' (15 mm) Style 20 Chrome Plated..,...,...., PIN 56-705.9-010 White Coaled . . . , , . , . . . , ,. PIN 56-705-4-010 White AAl9010....,.".... PIN 56-705-3-010 Brass Plated.,...,..,..... PIN 56-705-2.010 3/4' (20 mm) Style 30 Chrome Plated, . . . . , . . . , ,. PIN 56-705-9-011 White Coated. . . . . , . . . . ' ., PIN 56-705-4-011 White AAl9010' " ' , ,...,.. PIN 56-705-3-011 Brass Plated. , . , , . . ' , , , , .. PIN 56-705-2-011 3/4' (20 mm) Style 40 Chrome Plated...,....,.., PIN 56-700-9-010 While Coaled . , . . . . , . . . , " PIN 56-700-4-010 White AAl9010.,....,..", PIN 56-700-3-010 Brass Plated... ,. .. ",. ". PIN 56-700-2-010 . Eastern Hemisphere sales only, Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 . "tqeD / Fire & Building / Products Technical SeNices: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description rfiY'D) ~ See Fire Protection ~ VdS Submittal Sheet for Pressure Rating and fU:\ ili.r\C Listing/Approval \:!.Y~~ Information ~ The grooved fittings provide an economical and efficient method of changing direction. adding an outlet. reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: Figure 5108 and 5198 fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings, Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 5108 and 5198 fittings, Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction, Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions, Technical Data Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing / Approval information, Page 1 of 6 Material: Cast Figures: 201,210.219.250,260,501,510, 519, 51 ODE, 501S, 510S and 519S- Ductile iron conforming to ASTM A-536, Grade 65-45-12 Fabricated Steel: Figures 391, 392, 393, 312, 313,321,327,341 and 350 - Carbon Steel, (Sizes 1 W - 6" are Schedule 40); (Sizes 8" - 12" are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: . Non-lead orange paint . Fire brigade red (optional) non-lead paint · Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name, Please specify the quantity, figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U,S" Canada. and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards ofthe National Fire Protection Association (e,g., NFPA 25), in addition to the standards of any authority having jurisdiction, The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Rre Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with T yco Fire Products orfor products and components which have been subject to misuse, improper installation. corrosion, orwhich have not been installed. maintained, modified or repaired in accordance with applicable Standards of the National Rre Protection Association (NFPA). and/orthe standards of any other Authorities Having Jurisdiction. Materials found by Tyco Rre Products to be defective shall be either repaired or replaced, at Tyco Rre Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. T yco Fire Products shall notbe responsible forsprinkJersystem design errors orinaccurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL 1YCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT. STRICT L1ABILl1Y OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAG ES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCO RREPRODUCTSWftS INFORMED ABOUT THE POSSIBILl1Y OF SUCH DAMAGES, AND IN NO EVENT SHALL 1YCO FIRE PRODUCTS' L1ABILl1Y EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TFP1810 Page 2 of 6 TFP1810 Figures 201, 210, 219, and 260 ~to-t )/ /I C to E i L ' Q,-'.-.-' ! r ! C to E :- C to E --==f-1 Figure 201 Figure 210 !-CtoE1 -$D ! I -'-'--r-'-'-' 1 ! Figure 260 Figure 219 Friction Resistance' (Exoressed as Eauivalent Straioht Pioe) Elbow Tee Size 90. 450 Branch Run Inches Feet Feet Feet Feet mm Meters Meters Meters Meters lV. 1.9 1.0 4.8 1.9 42.4 0.6 0.3 1.5 0,6 1'12 2,3 1.2 5.8 2.3 48.3 0.7 0.4 1.8 0.7 2 3.2 1.6 8.0 3,2 60.3 1.0 0.5 2.5 1.0 2'12 3.9 2.0 9.8 3,9 73.0 1,2 0,6 3.0 1,2 76.10000 4,1 2.1 10,3 4.1 1.2 0,6 3,1 1,2 3 4,9 2.4 12.2 4,9 88,9 1,5 0.7 3.7 1.5 108.00000 6.5 3.3 16,3 6.5 2.0 1.0 5.0 2.0 4 6.5 3.3 16.3 6.5 114,3 2.0 1.0 5.0 2.0 133.00000 8.0 4,0 20.0 8.0 2.4 1,2 6,1 2.4 139,70000 8,0 4.1 20,0 8.0 2.4 1.3 6,1 2,4 5 8.2 4,1 20.5 8.2 141,3 2,5 1.3 6.3 2,5 159.00000 9.5 4.8 23.8 9,5 2.9 1.4 7.2 2.9 165,10000 9.5 4,8 23.8 9.5 2.9 1.4 7.2 2.9 6 9,9 5.0 24.8 9.9 168,3 3.0 1.5 7.6 3,0 216,30000 13.1 6,6 32.8 13.1 4.0 2,0 10.0 4.0 8 13.1 6.6 32.8 13.1 219.1 4,0 2.0 10,0 4.0 10 16,5 8.3 41,3 16.5 273,0 5.0 2,5 12.6 5,0 12 19.9 9,9 49.7 19,9 323.4 6,1 3,0 15,1 6.1 For reducing tees and branches, use the value thai is corrosponding to the branch size. Example: lor 8" x 8" x 2~ tee, the branch value 2" is 8.0 feel. Friction resistance for all elbows and tees except Figures 51 OS and519S, Figure 201 Figure 210 Figure 219 Figure 260* 450 Elbow 900 Elbow Tee End Cap Nominal Cto E Appx, WI. Cta E Appx. WI. Cta E Appx, WI. Eta E Appx, WI. Size Inches Lbs, Inches Lbs. Inches Lbs. Inches Lbs, mm Ka, mm K(J. mm Ka. mm K(J. 1'/." 1.75 0,9 2.75 1.0 2.75 1.4 0.88 0.4 44,5 0.4 69.9 0.5 69,9 0.6 22.4 0,2 1'/2" 1,75 1,1 2.75 1.2 2.75 1,8 0.88 0.6 44,5 0,5 69.9 0,5 69.9 0.8 22.4 0,3 2" 2.00 1.8 3,25 2.0 3.25 2.7 0.88 0,9 50,8 0.8 82.6 0.9 82.6 1,2 22.4 0.4 2'/2' 2.25 2,2 3.75 3.0 3.75 5.8 0.88 0,9 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 76.1 mm 2.25 2,2 3.75 3.0 3.75 5.8 0.94 1.1 57,2 1.0 95,3 1.4 95.3 2.6 23.9 0.5 3" 2.50 3.5 4.25 4.5 4.25 7.0 0,88 1,1 63,5 1.6 108,0 2,0 108.0 3,2 22.4 0.5 108,Omm 2.88 5,5 4,75 8,5 4.75 11.5 73.0 2,5 120.7 3,9 120.7 5.2 . - 4" 3.00 5.2 5.00 8,5 5.00 11.8 1.00 2,6 76,2 2.4 127,0 3,9 127.0 5.4 25.4 1.2 133,Omm 3.25 7.7 5.25 11.3 5.25 10.6 82.6 3.5 133.4 5.1 133.4 4.8 - 139.7mm 3.25 7.7 5.50 11.3 5.50 15,3 0,92 4,7 82.6 3.5 139.7 5.1 139.7 6,9 23.4 2,1 5" 3.25 8,5 5,50 13,5 5,50 17.0 1.00 5,0 82.6 3.9 139.7 6,1 139.7 7.7 25.4 2.3 159.0mm 3.50 12.0 6.00 14,6 6.00 13.9 88.9 5.4 152.4 6.6 152.4 6.3 - 165.1mm 3.50 12,0 6,50 18.5 6.50 26.0 1,00 7.5 88.9 5.4 165.1 8.4 165.1 11,8 25.4 3.4 6" 3.50 12.0 6,50 18,5 6.50 26.0 1.00 7,5 88.9 5.4 165,1 8.4 165,1 11.8 25.4 3.4 216,3mm 4,25 23.0 7,75 36.5 7,75 45.0 - 108.0 10.4 196.9 16,6 196.9 20.4 . 8" 4,25 23.0 7.75 36.5 7,75 45,0 1.19 12,8 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5,8 10" 4,75 31.0 9.00 60.0 9.00 72.1 1,25 20,0 120.7 14.1 228.6 27.2 228,6 32.7 31.8 9,1 12" 5,25 40,0 10.00 67.0 10,00 92,5 1.25 36.0 133.4 18,1 254.0 30.4 254,0 42.0 31.8 16,3 ~ . Available with tapped plugs, contact Tyco Fire & Building Products, Page 3 of 6 Figures 501, 510, 519 and 510DE ~r ~toE :-CtOE~ Figure 510 Figure 519 Figure 510DE !-CtoE--! -.-.. T Cta E A-:-CtoE~ -, Figure 501 Figure 501 Figure 510 Figure 519 Figure 510DE 450 Elbow 900 Elbow Tee 900 Drain Elbow Nominal Cto E Appx. WI. CtoE Appx, WI. Cto E Appx, WI. Cto E A B Appx, WI. Size Inches Lbs, Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. mm Ka. mm KQ. mm KQ. mm mm mm Ka. 1'/" 1.75 0.9 2.75 1.0 2.75 1.4 44.5 0.4 69.9 0,5 69.9 0.6 - - - - 1'12" 1,75 1.1 2.75 1.2 2.75 1,8 44,5 0.5 69,9 0,5 69.9 0,8 - - - - 2" 2.00 1,8 3.25 2,0 3.25 2.7 50.8 0.8 82,6 0.9 82.6 1,2 - - - - 2'/2 2.25 2.2 3.75 3.0 3,75 5.8 3,75 2.00 2.75 2.7 57,2 1,0 95,3 1.4 95.3 2,6 95.3 50,8 69.9 1.2 3" 2,50 3.5 4.25 4,5 4.25 7.0 4.25 2.34 2,75 3.7 63.5 1.6 108,0 2,0 108.0 3,2 108.0 59.4 69.9 1.7 4" 3.00 5.2 5.00 8,5 5.00 11.8 5,00 2.85 2,75 7,0 76,2 2.4 127.0 3,9 127,0 5.4 127.0 72.4 69,9 3.2 5" 3.25 8.5 5.50 13,5 5.50 17.0 5,50 3.38 2.75 13,0 82,6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 5.9 6" 3.50 12,0 6.50 18.5 6,50 26,0 6,50 3.92 2.75 13.4 88.9 5.4 165,1 8.4 165,1 11,8 165.1 99.6 69,9 6.1 8' 4.25 23.0 7,75 36,5 7,75 45.0 7.75 4.95 2.75 26.3 108.0 10.4 196.9 16,6 196,9 20.4 196.9 125.7 69,9 11.9 Figures 5015, 5105 and 5195 ~I brJtoE :-CtoE~ ~tot / I' t ,( C to E i L ' !-CtOE--! -r Figure 501 S Figure 510S' Figure 519S' Friction Resistance 501 S, 510S & 519S (Expressed as Equivalent Straiqht Pipe) Elbow Tee Size 900 450 Branch Run Inches Feet Feet Feet Feet mm Meters Meters Meters Meters 2 3.2 1.6 8,0 3.2 60,3 1.0 0,5 2.5 1.0 2'12 3.9 2,0 9.8 3.9 73.0 1,2 0.6 3.0 1,2 76.1 mm 4.1 2.1 10.3 4,1 1.2 0,6 3.1 1.2 3 4.9 2.4 12,2 4.9 88.9 1.5 0.7 3.7 1,5 4 6,5 3,3 16.3 6,5 114.3 2.0 1.0 5,0 2,0 139.7mm 8,0 4,1 20,0 8.0 2.4 1.3 6.1 2.4 5 8,2 4.1 20.5 8,2 141.3 2,5 1,3 6.3 2.5 165.1mm 9.5 4,8 23,8 9,5 2.9 1.4 7.2 2,9 6 9,9 5.0 24.8 9,9 168.3 3.0 1.5 7.6 3.0 8 13.1 6.6 32.8 13,1 219,1 4.0 2.0 10.0 4,0 Figure 501 S Figure 510S Figure 519S 450 Elbow 900 Elbow Tee Nominal Cto E Appx WI. CtoE Appx. WI. CtoE Appx. WI. Size Inches Lbs, Inches Lbs. Inches Lbs. mm Kg, mm Kg. mm Kg, 2" 2.00 1.8 2.75 1.5 2.75 2.1 50.8 0.8 69,9 0.7 69.9 1.0 2'/2 2.25 2.2 3,00 2.2 3.00 3,0 57.2 1,0 76.2 1.0 76.2 1.4 76,1mm 2.25 2,2 3,00 2.3 3.00 3,1 57,2 1,0 76,2 1,0 76,2 1.4 3" 2.50 3.5 3.38 3.0 3.38 4.1 63.5 1.6 85.9 1.3 85,9 1.9 4" 3,00 5.2 4.00 5.6 4.00 7.7 76.2 2.4 101.6 2.6 101,6 3.5 139,7mm 3.25 7,7 4.88 8.6 4.88 12.0 82.6 3,5 124.0 3,9 124.0 5.4 5" 3,25 8,5 4.88 8.8 4.88 12.0 82.6 3,9 124,0 3.9 124,0 5.4 165,1mm 3.50 12,0 5,50 11,00 5.50 15.0 88.9 5.4 139.7 5,0 139.7 6.8 6" 3,50 12,0 5.50 11.2 5.50 15.2 88.9 5.4 139.7 5.1 139.7 6,9 8" 4.25 23.0 6.88 23.4 6,88 31.2 108.0 10.4 174.8 10,6 174,8 14.2 , , , , .Note: Figure 5105 and 5195 ""lOgS are specIal short radIUS 1IIIIngs wllb smaller center to end dimensions than standard grooved fittings. Depending on Ibe size and coupling used, there may be inlerferences at Ibe boll pads which requires reposilioning of the coupling orientation, The use olllange adapters is not recommended with Figures 5105 and 5195 fittings, Contact Tyco Fire Products for details. TFP1810 Page 4 of 6 r-E to Ej {[ill- Figure 250 Cast r-EtOE1 {]RID- Figure 350 Fabricated Sizes 3" to 6" r-EtOEj -p- Figure 350 Fabricated Sizes 8" to 12" TFP1810 Figures 250 and 350 Fiqures 250 and 350 Concentric Reducer - Groove x Groove Nominal Eto E Appx. WI. Nominal Eto E Appx. WI. Nominal Eto E Appx, WI. Size Inches Lbs, Size Inches Lbs. Size Inches Lbs, Inches mm Kg, Inches mm Kg, Inches mm Kg, *2 x 1 V. 2,50 1,0 *139,7mm x 3 3,50 4,2 *6 x 5 4,00 5,8 63,5 0.5 88.9 1,9 101,6 2,6 *2 x 1 '12 2,50 1,3 *139,7mm x 4 3,50 4.4 8x2 5.00 12.2 63,5 0,6 88,9 2.0 127.0 5.5 *2'12 x 2 2.50 1,2 5x1'12 3.50 4,6 8 x 2'12 5,00 12.1 63,5 0,5 88,9 2.1 127.0 5.5 *76.1mm x 1 '12 2.50 1.5 5x2 3,50 4,6 8x3 5.00 12.0 63.5 0.7 88,9 2.1 127.0 5,5 *76,1mm x 2 2,50 1,6 5 x 2'12 3.50 4,5 8x4 5,00 11,9 63.5 0,8 88.9 2,0 127,0 5.4 3x1'1. 2.50 1.3 5x3 3.50 4.4 8x5 5.00 11,3 63.5 0.6 88.9 2,0 127.0 5.1 3x1'12 2.50 1,3 *5 x 4 3.50 4.5 8x6 5,00 10,8 63.5 0.6 88.9 2,0 127,0 4,9 *3 x 2 2.50 1,3 *165,1mm x 3 4,00 5,5 10 x 4 6.00 21,9 63,5 0,6 101,6 2.5 152.4 10.0 *3 x 2'12 3.00 1,5 *165.1mmx4 4,00 6.0 10 x 5 6.00 21,6 76,2 0.7 101,6 2.7 152.4 9,8 *3x76,1mm 3.00 2,0 4.00 5,6 10 x 6 6.00 21.1 76.2 0.9 '165.1"", x 139,7"", 101,6 2.5 152.4 9.6 4x1'1. 3,00 2.2 *6 x 2 4,00 6.0 10 x 8 6,00 19.5 76.2 1.0 101.6 2.7 152.4 8.9 4x1'12 3.00 2,3 6 x 2'12 4,00 6,0 12 x 4 7,00 28,0 76.2 1.0 101,6 2.7 177.8 12.7 *4 x 2 3,00 2.3 *6 x 76.1mm 4.00 6.0 12 x 6 7,00 30,0 76.2 1.0 101,6 2.7 117.8 13.6 *4 x 2'12 3.00 2.3 6x3 4.00 6.0 12 x 8 7.00 28,0 76.2 1.0 101,6 2.7 177.8 12.7 *4x76.1mm 3,00 3,2 *6 x 4 4.00 5.9 12x10 7.00 33.0 76.2 1,5 101.6 2.7 177.8 15,0 4x3 3.00 2.6 *6 x 139.7mm 4.00 6.3 76.2 1,2 101,6 2.9 Note: Sizes marked with an asterisk n are only available in Figure 250 Cast. Sizes without an asterisk are only available in Figure 350 Fabricated. ADA CApID Patented ro~ r A - L PiJe Nominal Dimensions 0.0, Takeout Center to End Net Size Outlet A B C D WI. Inches NPT* Inches Inches Inches Inches Lbs, Inches mm mm mm mm Kg, '/2 1,25 1,75 1.89 0.77 31,8 44.5 48.0 0,3 1'/2 3/. 1,900 1.25 1,75 1.89 0.77 48,3 31.8 44.5 48,0 0.3 1 1.37 2.00 2.02 0,88 34,8 50,8 51.3 0.4 '12 1.25 1.75 1.89 0.92 31.8 44.5 48.0 0.4 2 3/. 2,375 1,25 1,75 1.89 0,92 60,3 31.8 44.5 48,0 0.4 1 1.37 2,00 2,02 1,06 34.8 50,8 51.3 0,5 '12 1.47 1,97 1.89 1,28 37.3 50,0 48,0 0,6 2'12 3/. 2,875 1.47 1,97 1,89 1,28 73,0 37.3 50,0 48.0 0,6 1 1,37 2,00 2.02 1,50 34,8 50,8 51,3 0.7 =T1 _._._._LJ . ISO.7 threaded outlets are available upon request. Page 5 of 6 g. B --t. CIO~' 7 . C 10 E TFP1810 Figures 391, 392, 393, 312 and 313 Figure 391 Figure 392 a Figure 393 Figure 312 Figure 313 Figures 391, Figure 312 Figure 313 392 and 393 22'120 Elbow 11'/.0 Elbow Adaoler Niooles Nominal E to E Appx, WI. C to E Appx. WI. Clo E Appx. WI. Inches Lbs, Inches Lbs. Inches Lbs, Size mm KQ, mm Kg. mm Kg, 1'/." 4,00 0,8 1,75 0.4 1.38 0.4 101.6 0.4 44.5 0,2 35,1 0,2 1'12" 4,00 0,9 1,75 0.5 1.38 0,5 101,6 0.4 44,5 0.2 35,1 0.2 2" 4,00 1.2 1.88 0.6 1,38 0.6 101,6 0.5 47.8 0,3 35.1 0,3 2'12' 4.00 1.9 2.00 0.7 1.50 1,1 101,6 0.9 50.8 0,3 38,1 0.5 3" 4.00 2.5 2.25 1.4 1,50 1,2 101.6 1,1 57.2 0,6 38,1 0,5 4' 6,00 5.5 2.63 2.4 1,75 2,2 152.4 2.5 66.8 1,1 44.5 1.0 5' 6.00 7.4 2.88 4,1 2.00 3.3 152.4 3.4 73.2 1,9 50.8 1.5 6' 6,00 9,5 3.13 5.6 2.00 4.6 152.4 4.3 79,5 2,5 50,8 2,1 8" 6,00 14.2 3,88 11,1 2,00 8,7 152.4 6.4 98,6 5.0 50.8 3,9 10" B.OO 27,0 4,38 14.0 2.13 9.1 203,2 12,2 11,3 6.4 54.1 4.1 12" 8,00 33,0 4,88 22.0 2,25 16,7 203,2 15.0 124,0 10,0 57.2 7.6 Figures 327 and 341 J~C.' l I i ! .- r C 10 E L Figure 327 , !' r E to E ~ Figure 341 Figure 327 Figure 341 Cross 150 Ibs. Flanae Adaoter Nominal C to E Appx. WI. E to E Appx, WI. nches Lbs, Inches Lbs, Size mm kQ. mm kQ, 1'/'- 2,75 2.0 4.00 2.8 69.6 0.9 101.6 1,3 1'12' 2.75 2,2 4.00 3.2 69,9 2,0 101.6 1.5 2' 3.25 2.7 4.0 5,2 82,6 1,2 101,6 2.4 2'12" 3.75 5,0 4.00 8,0 95.3 2.3 101.6 3,6 3' 4.25 7.1 4.00 10,2 108,0 3,2 101,6 4.6 4' 5.00 11.9 6.00 17,2 127.0 5.4 152.4 7.8 5' 5.50 17.1 6.00 21.4 139.7 7,8 152.4 9.7 6' 6,50 27,5 6,00 26,0 165.1 12.5 152.4 11,8 8" 7.75 47,0 6.00 38.4 196,9 21.3 152.4 11.4 10" 9.00 68.0 8.00 65.0 228,6 30,8 203,2 29,5 12" 10.00 107.0 8.00 91,0 254.0 48,5 203,2 41,3 Page 6 of 6 TFP1810 Figure 321 ~ C to E---! I -----1----- -1 c to E I Figure 321 Reducing Tee Nominal CtoE Appx, Wt. Nominal CtoE Appx, WI. Size Inches Lbs, Size Inches Lbs, Inches mm Ka, Inches mm Kg, 1'12 X 1'hx 1'.4 3.25 2,0 6x6x4 6,50 26,6 82,6 0,9 165,1 12,1 2x2x1'h 3,25 2,7 6x6x5 6,50 27,0 82.6 1,2 165,1 12,2 2'/2 x 2'h x 1'.4 3,75 4,2 8x8x2 7.75 36,2 95,3 1.9 196,9 16.4 2'h x 2'h x 1'12 3.75 4,2 8x8x3 7.75 36,5 95,3 1,9 196.9 16,6 2'h x 2'h x 2 3.75 4,3 8x8x4 7.75 36,6 95,3 2.0 196,9 16.6 3x3x1'h 4,25 5.3 8x8x5 7.75 36,8 108,0 2.4 196,9 16.7 3x3x2 4,25 5,5 8x8x6 7,75 37,0 108.0 2,5 196.9 16,8 3 x 3 X 2'12 4,25 5,8 10x10x2 9,00 57,1 108,0 2.6 228.6 25,9 4x4x 1';' 5,00 9,8 10x10x3 9,00 57.4 127.0 4.4 228.6 26,0 4x4x1'h 5.00 9,9 10x10x4 9.00 57,6 127.0 4,5 228.6 26,1 4x4x2 5,00 10.1 10x10x5 9.00 57,8 127,0 4.6 228,6 26,2 4x4x2'h 5.00 10.3 10x10x6 9.00 58,0 127,0 4.7 228.6 26,3 4x4x3 5,00 10,5 10x10x8 9.00 58.4 127.0 4,8 228.6 26.5 5x5x2 5,50 14.5 12x12x3 10.00 80.2 139.7 6,6 254,0 36.4 5x5x2'h 5,50 14,8 12x12x4 10.00 80.5 139.7 6.7 254,0 36.5 5x5x3 5.50 15,2 12x12x5 10,00 80,7 139.7 6.9 254.0 36.6 5x5x4 5.50 15.8 12x12x6 10,00 80.9 139.7 7.2 254.0 36.7 6x6x2 6,50 26,5 12x12x8 10,00 91.4 165.1 11,9 254.0 41.5 6x6x2'h 6,50 26,5 12x12x10 10.00 91.8 165,1 12,0 254,0 41,6 6x6x3 6.50 26.5 165.1 12,0 Figure 321 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-1000), Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system, Material and gasket selection should be verified to be compatible for the specific application, TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Certified Company Printed U,S.A, . tl/CD / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 705 Flexible Coupling General Description [LPC8] [VdS) I"fiL' ~ See Fire Protection \!.Y~~ Submittal Sheet for ~ Pressure Rating and Listing/Approvallnformation The Figure 705 Flexible Coupling is capable of pressures up to 300 psig (2068 kPa) depending on pipe size and wall thickness when used in fire protection services, It provides a dependable method of joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended lor dry pipe and freezer applications. WARNING The Figure 705 Aexible Coupling described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance 01 this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Figure: 705 Sizes: 1W' -12" Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing / Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Page 1 of 2 Protective Coatings: · Non-lead orange paint . Fire brigade red (optional) non-lead paint . Hot dipped galvanized conforming to ASTM A-153 BolVNuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) . Grade "An EPDMA violet color code ambientto + 1500F (+660C) for fire protection systems, Not recommended for hot water systems, · Tri-seal (Grade "E" EPDM), greencolorcode. . Prelubricated (Grade "An EPDMA) (See Data Sheet TFP1S9S for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name, Please specify the quantity, figurenumber, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "En EPDM Tri-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards ofthe National Fire Protection Association (e,g" NFPA 25), in addition to the standards of any authority having jurisdiction, The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. July 2004 It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyeo Rre Products are warranted solely to the original Buyer for ten '(1 O) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (1 O) years from date of shipment by Tyco Rre Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with T yeo Rre Products orfor products and components which have been subject to misuse, improperinstaJlation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Rre Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shaff be either repaired or replaced, at Tyco Rre Products' sole option. Tyco Rre Products neither assumes, nor authorizes any person to assumeforit,anyotherobligation in connection with the sale of products or parts of products. Tyco Rre Products shall notbe responsibleforsprinkfersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT. STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDINGBlJfNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCOAREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES AND IN NO EVENT SHALL TYCO FIRE PRODUCTS: LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN liEU OF ANY AND AU O77IER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUlAR PURPOSE. TFP1820 Page 2 of 2 TFP1820 Figure 705 Grooved Coupling B Pipe Max. *:t: Max.t Max.t Nominal Dimensions Deflection :t: Bolt Net 0.0. End Gap Pressure End load A B C oPer Inches/ Size" Wt. Size Inches Inches psi Lbs, Inches Inche s Inches Coupling Foot Dia, x Lg, Lbs. mm mm kPa N mm mm mm mm/m Kg, 1 v." 1.660 0.13 300 649 2,56 4,19 1.81 40 - 19' 0.90 3/8" x 2'/4" 1.5 42.4 3.3 2,068 2,887 65.0 106.4 46.0 75.0 M10x57 0.7 1 'Iz" 1.900 0.13 300 850 2.75 4.44 1,81 30 - 46' 0.79 3/6" x 2'/4" 1,6 48.3 3.3 2,068 3,781 69.9 112.8 46.0 65.8 M10x57 0.7 2" 2,375 0.13 300 1,328 3.25 4,88 1.88 30 - l' 0,63 3/6" x 21/4" 1.7 60.3 3,3 2,068 5,907 82,6 124.0 47.8 52.5 M10 x 57 0.8 2'1z" 2,875 0.13 300 1 ,947 3.69 5.50 1,88 20 - 29' 0.52 3/6" x 21/4" 2,0 73.0 3.3 2,068 8,660 93.7 139.7 47.8 43.3 M10x57 0.9 3,000 0.13 300 2,120 4.00 5.75 1.88 20 - 23' 0.50 M12 x 76 3.1 76.1 mm 76,1 3.3 2,068 9,430 101.6 146.1 47.8 41.7 1.4 3" 3,500 0.13 300 2,885 4,38 6.50 1.88 20 - 3' 0.43 '12" x 3" 3,0 88.9 3.3 2,068 12,832 111.3 165.1 47.8 35.8 M12 x 76 1.4 108.0mm 4.250 0,25 300 4,256 5.50 7.50 2,06 30 - 22' 0.70 M12 x 76 4,2 108.0 6.4 2,068 18,931 139.7 190.5 52.3 58.3 1.9 4" 4.500 0.25 300 4,769 5,69 7,75 2.06 30 - ii' 0,67 112" x 3" 4,0 114.3 6.4 2,068 21,213 144.5 196.9 52.3 55.8 M12 x 76 1,8 133.0mm 5,250 0.25 300 6,494 6,56 9.50 2,06 20 - 44' 0.56 M16 x 83 7.2 133.0 6.4 2,068 28,885 166.6 241.3 52.3 46.7 3.3 139,7mm 5,500 0.25 300 7,127 6.81 9.75 2.06 20 - 36' 0.56 M16 x 83 7,2 139.7 6.4 2,068 31,701 173.0 247.7 52.3 46.7 3.3 5" 5,563 0,25 300 7,288 6.88 9.75 2,06 20 - 35' 0.54 5/8" x 31/4" 7,0 141.3 6.4 2,068 32,417 174.8 247.7 52.3 45.0 M16 x 83 3,2 159,Omm 6,250 0,25 300 9,204 7,56 10.31 2.06 20 - 17' 0,48 M16 x 83 7.4 159.0 6.4 2,068 40,939 192.0 261.9 52.3 40.0 3.4 165.1mm 6,500 0.25 300 9,950 7.75 10.69 2,06 20 - 12' 0.46 M16 x 83 7.1 165.1 6.4 2,068 44,258 196.9 271.5 52.3 38.3 3.2 6" 6.625 0.25 300 10,336 7,94 10,69 2.06 20 - 10' 0.45 5/8" x 3'/4" 7.1 168.3 6.4 2,068 45,975 201.7 271,5 52.3 37.5 M16 x 83 3,2 216.3mm 8.500 0,25 300 17,024 10,07 13,50 2,31 1 0 - 40' 0.35 M20 x 121 12.4 216.3 6.4 2,068 75,723 255.8 342.9 58.7 29.2 5.6 8" 8,625 0.25 300 17,519 10,19 13.56 2.50 1 0 - 40' 0.35 3/4" x 43/4" 14.5 219.1 6.4 2,068 77,925 258,8 344.4 63.5 29.2 M20 x 121 6.6 10" 10.750 0,25 250 22,679 12,69 16.38 2,63 1 0 - 20' 0,28 1"x6'12" 28,0 273.0 6.4 1,724 100,876 322,3 416.1 66,8 23.3 M24 x 165 12.7 12" 12.750 0,25 250 31,903 14.94 18,88 2.63 10-7' 0.23 1" x 6'12" 36.5 323.9 6.4 1,724 141,905 379.5 479.6 66.8 19.2 M24 x 165 16.6 . Maximum available gap between pipe ends, Minimum gap = o. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings, .. Gold color coded metric bolt sizes are available upon request. :j: Max End Gap and Deflection is for cut grooved standard weight pipe, Values for roll grooved pipe will be '/2 that of cut grooved. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded, Always read and understand the installation instructions (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system, Material and gasket selection should be verified to be compatible for the specific application, TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Certified Company Printed U,SA tqCD / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 577 Rigid Coupling - Patented General Description (LPCB) [VdS) , ~ See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approval Information The Figure 577 Rigid Coupling pro- vides a rigid joint by firmly gripping along the circumference of the pipe grooves. Rigid couplings are preferred for dry pipe and freezer applications, Figure 577 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading, or using flanges. It is capable of pressures up to 300 psig (2069 kPa) depending on pipe size and wall thickness when used in fire protection services, Rigid Couplings are recommended for dry pipe and freezer applica- tions, WARNING The Figure 577 Rigid Coupling de- scribed herein must be installed and maintained in compliance with this document, in addition to the standards of any other authorities having jurisdic- tion, Failure to do so may impair the integrity of this device. The owner is responsible for maintain- ing their system and devices in proper operating condition. The installing contractor or manufacturer should be contacted with any questions. Page 1 of 2 Technical Data Figure: 577 Sizes: 1-1/4" - 8" Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing/Approval in- formation. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12. Protective Coatings: . Non-lead orange paint. . Fire brigade red (optional) non-lead paint. · Hot dipped galvanized conforming to ASTM A-153. Bolts/Nuts: Track Head Bolts - con- forming to ASTM A-183, Zinc Plated, (Min, Tensile;::: 110,000 psi/758,422 kPa). Metric - conforming to ASTM F568M. Gasket: . Prelubricated Grade "An EPDMA violet color code ambient to + 1500 F (+660C) for fire protection systems. Not recommended for hot water sys- tems. · Tri-seal (Grade "En EPDM), green color code for use in dry pipe or freezer system. (See Data Sheet TFP1865 for aid in selecting proper gasket.) Ordering Information When placing an order, indicate the full product name, Please specify the quantity, figure number, type of gas- ket, Grade "An EPDMA, Prelubricated (Grade "An EPDMA) or Grade "En EPDM Tri-Seal, and size. Grinnell Grooved Piping Products, valves, accessories, and other prod- ucts are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. JULY, 2005 Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes, Limited Warranty Products manufactured by Tyco Fire & Building Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire & Building Products. No warranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire & Building Products or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applica- ble Standards of the the standards of any other Authorities Having Jurisdic- tion, Materials found by Tyco Fire & Building Products to be defective shall be either repaired or replaced, at Tyco Fire & Building Products' sole option. Tyco Fire & Building Products neither TFP1854 Page 2 of 2 assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire & Building Products shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS BE LIABLE, Figure 577 Grooved Coupling IN CONTRACT, TORT, STRICT LI- ABILITY OR UNDER ANY OTHER LE- GAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE & BUILDING PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT -lcl TFP1854 SHALL TYCO FIRE & BUILDINC? PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- EQSE.. Pipe Max! + Max. t Max, t Nominal Dimensions Bolt Net 0.0, End Gap Pressure End Load A B C Size" Weight Size Inches Inches psi Lbs. Inches Inches Inches Dia, x Lg, Lbs. mm mm kPa N mm mm mm Kg 1 1/4" 1.660 0.06 300 649 2.68 4.21 1.65 3/8" x 2 1/4" 1.3 42.4 1.5 2,068 2,888 68 107 42 M10x57 0.6 1 1/2" 1. 900 0,06 300 851 2.91 4,45 1.65 3/8" x 2 1/4" 1.5 48.3 1.5 2,068 3,783 74 113 42 M10 x 57 0.7 2" 2.375 0.06 300 1329 3,39 5,00 1.69 3/8" x 2 1/4" 1.8 60.3 1,5 2,068 5,912 86 127 43 M10x57 0.8 21/2" 2.875 0.06 300 1947 3,90 5.43 1,77 3/8" x 21/4" 2.0 73,0 1.5 2,068 8,663 99 138 45 M10 x 57 0.9 76.1 mm 3.000 0.06 300 2121 3.98 5,59 1.77 3/8" x 21/4" 2,0 76.1 1.5 2,068 9,433 101 142 45 M10 x 57 0.9 3" 3.500 0.06 300 2886 4.49 6,14 1,77 3/8" x 2 1/4" 3.3 88,9 1.5 2,068 12,839 114 156 45 M10x57 1,5 4" 4.500 0.19 300 4771 5,71 7.52 1.85 3/8" x 2 1/4" 3.3 114.3 4,8 2,068 21,223 145 191 47 M10x57 1.5 139,7 mm 5,500 0,19 300 7127 6.81 8,74 1,93 1/2" x 3" 5,3 139.7 4.8 2,068 31,704 173 222 49 M12 x 76 2.4 5" 5.563 0.19 300 7291 6,85 8,82 1.93 1/2" x 3" 5.3 141.3 4,8 2,068 32,434 174 224 49 M12 x 76 2.4 165,1 mm 6,500 0,19 300 9955 7.80 9,76 1.93 1/2" x 3" 5,7 165.1 4,8 2,068 44,280 198 248 49 M12 x 76 2.6 6" 6,625 0,19 300 10341 7.91 9.88 1.93 1/2" x 3" 5.9 168.3 4,8 2,068 46,000 201 251 49 M12 x 76 2.7 8" 8,625 0.19 300 17527 10.24 12.80 2.40 5/8" x 3 1/4" 11,7 219,1 4,8 2,068 77,966 260 325 61 M16x83 5.3 . Maximum available gap between pipe ends. Minimum gap = 0, t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness, Contact Tyco Fire & Building Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. .. Gold color coded metric bolt sizes are available upon request. + Max, End Gap is for cut grooved standard weight pipe, Valves for roll grooved pipe will be 1/2 that of cut grooved, Figure 577 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the coupling keys. which make the Figure 577 perfectly suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded, Always read and understand the installation instructions (IH-l000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system, Material and gasket selection should be verified to be compatible for the specific application, Certified Company TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 . -tileD / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 730 Mechanical Tees · Threaded / Grooved General Description ~@iC) See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approvallnformation The Figure 730 Mechanical Tees may be used for any tee connection where a threaded or grooved outlet is needed. They may be converted into a cross when necessary, WARNING The Figure 730 Mechanical Tee described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition, The installing contractor or sprinkler manufacturer should be contacted with any Questions, Technical Data Figure: 730 Outlet: Threaded or Grooved Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing / Approval information, Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Page 1 of 4 Protective Coatings: . Non-lead orange paint · Fire brigade red (optional) non-lead paint . Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) · Grade "En EPDM, green color code (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name, Please specify the Quantity, figure number, type of gasket, Grade "En EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S" Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e,g" NFPA 25), in addition to the standards of any authority having jurisdiction, The installing contractor or product manufacturer should be contacted relative to any questions, Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service, September 2004 Limited Warranty Products manufactured by Tyco Rre Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by T yco Rre Products, No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Rre Products or for products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), andlorthe standards of any other Authorities Having Jurisdiction, Materials found by T yco Rre Products to be defective shall be either repaired or replaced, at Tyco Rre Products' sole option, Tyco Rre Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Rre Products shall not be responsible forsprinklersystem design errorsorinaccurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDINGBUTNOT LIMITED TO lABOR CHARGES, REGARDLESS OF WHETHERTYCORREPRODUCTSWftSlNFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL TYCO ARE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY fS MADE IN UfU OF ANY AND AU OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTlCIRAR PURPOSE, TFP1860 Page 2 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Threaded) " B Figure 730 Mechanical Outlet Tee (Threaded) Figure 730 Mechanical Outlet Cross (Threaded) Nom, Size Hole Dia,* Nominal Dimensions Tee Cross Hole Max, A B C D E Bolt NetWt. NetWt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Size" Lbs, Lbs. mm mm mm mm mm mm mm Dia, x Lg. Kg. Kg, 2" X 112", 3/4", 1" 1.50 1.63 2,62 4.88 3,07 2,12 1,59 3/8" x 2'1.' 2,2 2.6 38,1 41,3 66.5 124.0 78.0 53,8 40.4 M10 x 57 1,0 1.2 2" x 1'1." 1.75 1.88 2,78 4.88 3.32 1.93 1,59 3/e" X 2'1.' 2.5 3.3 44.5 47.6 10.6 124.0 84.3 49,0 40.4 M10 x 51 1,1 1,5 2" x 1'12' 1.75 1.88 2,75 4,88 3.32 1.93 1.59 3/e' X 2'1.' 2,5 3,7 44.5 47.6 69.9 124,0 84,3 49.0 40.4 M10 x 57 1,1 1.7 2'1>" x '/2', 3/.", 1" 1,50 1.63 2.88 5.25 3.07 2.38 1.81 3/8" x 2'1. 2,7 3.1 38.1 41.3 13,2 133.4 18.0 60.5 46.0 Ml0 x 51 1.2 1.4 2'/2' x 1'1. 2.00 2.13 3,00 5,25 3,56 2.19 1,81 3/e" X 2'1. 3.1 3,9 50.8 54,0 16.2 133.4 90.4 55.6 46,0 M10 x 51 1.4 1.8 2'12" x 1'/2' 2,00 2.13 3.07 5.25 3,59 2,17 1.81 3/8" x 2'1. 3,3 4.3 50.8 54,0 18,0 133.4 91.2 55.1 46,0 M10 x 57 1,5 1.9 2'1>' x 2" 2.00 2.13 3,19 5,25 4,00 2.44 1,81 3/e" X 2'1." 3,5 4.4 50,8 54.0 81.0 133.4 101.6 62,0 46,0 Ml0 x 57 1.6 2.0 76.1mm x '/2',3/.,1" 1.50 1.63 2,94 5,62 3,07 2.44 1.87 2.7 3.1 38,1 41,3 74,5 142.7 18.0 62.0 47,5 M10 x 57 1.2 104 76,1 mm x 1'/0" 2.00 2.13 3.06 5.62 3,56 2.25 1,87 3,1 3,9 50,8 54,0 71.1 142.7 90.4 57.2 47.5 M10 x 57 1.4 1.8 76.1mm x 1'1>" 2,00 2,13 3,13 5,62 3.56 2,25 1,87 3.3 5.1 50,8 54.0 79,5 142.7 90.4 57,2 47.5 M10 x 57 1.5 2.3 76,1mm x 2' 2,50 2.63 3,25 5.62 4.00 2.50 1,87 4,1 5,9 63.5 66.7 82,6 142.7 101.6 63.5 47,5 M10 x 57 1.9 2.7 311 x 112") 3/411,111 1.50 1.63 3.19 6,13 3,07 2.56 2,21 '12" x 3" 3,7 4.5 38.1 41,3 81,0 155.7 18.0 65,0 56,1 M12 x 16 1.7 2,0 3" x 1'1.' 1.75' 1,88 3,34 6.13 3,32 2,50 2.21 '/2" x 3" 3.9 4.9 44,5 41.6 84.8 155.7 84,3 63,5 56.1 M12 x 76 1.8 2.2 3" x 1'12" 2,00 2,13 3.38 6,13 3.56 2.48 2,21 '12' x 3' 4.2 5.5 50,8 54.0 85,9 155.7 9004 63.0 56.1 M12 x 76 1.9 2.5 3'1 x 211 2.50 2.63 3,50 6,13 4.09 2.75 2.21 'I>' x 3" 4,7 6,5 63.5 66.7 88,9 155.7 103.9 69.9 56.1 M12 x 16 2.1 2.9 411 x '12M, 3/4\ 111 1.50 1.63 3,69 7.13 3.07 3,06 2.78 '/2" x 3" 5,5 7,1 38.1 41.3 93.7 181.1 78,0 71.1 70,6 M12 x 76 2,5 3,2 4" x 1'1.' 1,75' 1.88 3.92 7.13 3.32 3.00 2.78 '/2" x 3" 5.5 7.1 44,5 41.6 99.6 181,1 84,3 76.2 70.6 M12 x 76 2,5 3.2 4' x 1'12" 2.00 2.13 4,00 7,13 3.56 2.98 2,78 .112" x 3" 5,5 7,1 50.8 54.0 101,6 181.1 90.4 75.7 70,6 M12 x 76 2.5 3.2 4" x 2" 2.50 2.63 4,00 7.13 4.06 3.25 2.78 '12" x 3" 6,0 8,1 63.5 66.7 101.6 181.1 103.1 82,6 70,6 M12 x 76 2.7 3.7 4" x 2'12" 2,75 2,88 4,00 7.13 4,38 3,12 2,78 '/2' x 3" 6.0 8,1 69,9 73,0 101.6 181,1 111.3 79.2 70,6 M12 x 76 2.7 3.7 4'x76.1mm 2.75 2.88 4,00 7,13 4,38 3.12 2.78 6,0 8,1 69,9 73,0 101.6 181,1 111,3 79,2 70,6 M12x76 2.7 3.7 4' x 3' 3,50 3.63 4,13 7,13 5.13 3.31 2.78 '/2' x 3" 7,0 13,5 88.9 92.1 104,9 181.1 130,3 84.1 70,6 M12 x 76 3,2 6,1 +- Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/8" of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating 01 the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe. such as dry pendants, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyeo Fire Products. ~. Gold color coded metric bolt sizes are available upon request Nole: Outlet threads conforming to ISO 7.1 are available, contact Tyco Fire Products for details. Page 3 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Threaded) B Figure 730 Mechanical Outlet Tee (Threaded) Figure 730 Mechanical Outlet Cross (Threaded) Nom, Size Hole Dia.:j: Nominal Dimensions Bolt Tee Cross Hole Max. A B C D E Size" NetWt. NetWt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Dia. x Lg, Lbs, Lbs. mm mm mm mm mm mm mm Kg. Kg, 2.00 2.13 4.63 8,13 3.56 4.00 3.37 5/0" x 43/." 6.5 7.7 5' x 1'/2" 50,8 54,0 111.6 206.5 90.4 101,6 85,6 M16 x 121 2.9 3.5 2,50 2.63 4.63 8,13 4.06 3,88 3,37 5/0' x 43/.' 7.1 8.1 5" x 2' 63.5 66.7 117,6 206.5 103,1 98,6 85.6 M16 x 121 3.2 3.7 2,75 2.88 4.75 8.13 4.38 3,88 3.37 5/0" x 43/'- 7.3 8.7 5" x 2'/2" 69.9 73,0 120.7 206,5 111.3 98,6 85.6 M16 x 121 3.3 3.9 2,75 2.88 4.75 8,13 4.38 3,88 3,37 M16 x 121 7.3 8,7 5' x 76.1mm 69.9 73.0 120.7 206,5 111,3 98.6 85.6 3.3 3,9 3,50 3.63 5.00 8.13 5.13 4,06 3.37 5/0' x 43/." 7.6 14.7 5" x 3" 88.9 92.1 127,0 206.5 130,3 103.1 85.6 M16 x 121 3.4 6.7 2.00 2,13 5.13 9.25 3.56 4.25 3,90 M16x121 6,9 7,9 165,1mm x 1'/'- 50,8 54,0 130.3 235,0 90,4 108.0 99.1 3.1 3,6 2.00 2.13 5,13 9.25 3.56 4,04 3,90 M16x121 7.4 8.9 165.1mm x 1'12' 50.8 54.0 130.3 235,0 90.4 102.6 99.1 3.4 4.0 2.50 2.63 5.13 9.25 4.06 4.31 3,90 M16 x 121 7.5 8.9 165.1mm x 2" 63,5 66.7 130.3 235.0 103.1 109.5 99.1 3A 4.0 2.75 2.88 5.13 9.25 4.38 4,18 3.90 M16x121 7,5 11.1 165,1 mm x 2'12' 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 M16 x 121 7.5 11,1 165,1mm x 76,1mm 69,9 73,0 130.3 235,0 111.3 106.2 99.1 3.4 5,0 3.50 3.63 5.50 9.25 5.13 4.37 3,90 M16 x 121 9,5 14.1 165.1mmx3' 88.9 92,1 139.7 235.0 130.3 1/1.0 99,1 4.3 6.4 4.50 4.63 5.38 9,25 6,13 4,56 3,90 M16x121 10.0 20.1 165,1mmx4" 114.3 1/7.5 136.7 235.0 155.7 115.8 99.1 4.5 9.1 2.00 2.13 5.13 9.25 3.56 4.25 3.90 5/0" x 43/'- 6.9 7.9 6" x 1'/'" 50.8 54.0 130,3 235.0 90.4 108,0 99,1 M16 x 121 3.1 3.6 2.00 2.13 5.13 9.25 3.56 4.04 3,90 5/0" x 43/." 7.4 8.9 6" x 1'/2' 50.8 54,0 130.3 235.0 90A 102.6 99,1 M16 x 121 3.4 4,0 2,50 2.63 5.13 9,25 4,06 4.31 3.90 5/0" x 43/'" 7.5 8.9 6" x 2' 63.5 66.7 130.3 235.0 103.1 109.5 99.1 M16x 121 3.4 4.0 2.75 2.88 5.13 9,25 4.38 4.18 3.90 5/0" x 43/." 7,5 11.1 6" x 2'12' 69.9 73.0 130,3 235.0 111.3 106,2 99.1 MI6 x 121 3.4 5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 M16 x 121 7.5 11.1 6' x 76,1mm 69,9 73.0 130.3 235.0 111,3 106.2 99.1 3A 5.0 3,50 3.63 5,50 9,25 5.13 4.37 3.90 5/0" x 43/'- 9.5 14.1 6' x 3" 88.9 92,1 139.7 235.0 130.3 111,0 99.1 M16 x 121 4.3 6.4 4.50 4.63 5,38 9.25 6.13 4.56 3.90 5/0" x 43/." 10.0 20,1 6" x 4" 114.3 117.5 136.7 235.0 155.7 115.8 99.1 M16 x 121 4,5 9,1 2.75 2.88 6.25 12.50 4.38 5,12 4.90 3/.' x 43/4' 10,2 12.1 8" x 2'12" 69,9 73.0 158.8 317.5 111,3 130.0 124.5 M20 x 121 4,6 5,5 2,75 2,88 6.25 12,50 4,38 5,12 4.90 M20 x 121 10.2 12,1 8" x 76,1 mm 69,9 73,0 158.8 317.5 111.3 130.0 124.5 4,6 5.5 3,50 3.63 6.50 12.50 5.13 5.37 4,90 3/'" x 43/'- 12.5 15.1 8" x 3" 88.9 92.1 165.1 311.5 130.3 136.4 124,5 M20 x 121 5.7 6,8 4.50 4,63 6.38 12,50 6,13 5,56 4.90 3/." x 43/." 12.5 21.1 8" x 4" 114.3 117,5 162,1 311.5 155.7 14/,2 124,5 M20 x 121 5.7 9,6 ~ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 'I," of the hole to be certain it is free from conditions that would affect proper gasket sealing, Remove any sharp or rough edges from the hole or upper housing contact area. that might affect assembty. proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service, For crosses. ensure double outlet holes are aligned on opposite sides of the pipe, The use of threaded products other than steel pipe, such as dry pendents. etc, may not be compatible with the temale threaded outlet on the Mechanical Tee, Always confirm compatibility by contacting Tyco Fire Products, ~. Gold color coded metric bolt sizes are available upon request. Note, Outlet threads conforming 10 ISO 7.1 are available. contact Tyco Fire Products tor details. Page 4 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Grooved) , Figure 730 Mechanical Outlet Grooved Tee Nominal Hole Dia,; Nominal Dimensions Bolt Tee Cross Size Hole Max, A B C E NetW I. NetWI. Run x Inches Inches Inches Inches Inches Inches Size .. Lbs. Lbs, Branch mm mm mm mm mm mm Dia, x Lg, Kg, Kg. 2'x1W 1.75 1.88 2,78 4,88 3,32 1.59 'fe'x2'1, 2,5 3,3 44.5 47.6 70.,6 124,0. 84,3 40..4 Mlo.x57 1,1 1,5 2'x 1'h' 1.75 1.88 2,62 4,88 3,32 1.59 3/. x 2'1, 2,5 3.7 44,5 47.6 66.5 124.0. 84,3 4aA Mlax57 1.1 1.7 2'h'x1W 2,00 2,13 3,00 5,25 3,56 1.81 'fa'x2'1, 3,1 3,9 50..8 54,0. 76.2 133.4 90.4 46,0. Mlax57 1.4 1,8 2'I,x1'f,' 2,00 2.13 3,0.7 5,25 3,59 1.81 3/,'x2W 3,3 4,3 50.,8 54,0. 78,0. 133.4 91,2 46,0. M1Dx57 1,5 1,9 2'12'x2' 2,00 2,13 3,19 5.25 4.00 1.81 'I,' x 2'1, 3,5 4,4 50..8 54.0. 81,0. 133.4 10.1,6 46,0. Mlo.x57 1.6 2,0. 76,1"",x 1'14 2,00 2,13 3,06 5,62 3,56 1.87 M10 x 57 3.1 3,9 50.8 54,0. 77.7 142] 90.4 47.5 1.4 1.8 76,1"""x1W 2,00 2,13 3,13 5,62 3,56 1.87 M10 x 57 3,3 5,1 50.,8 54,0. 79,5 142] 90.4 47.5 1.5 2,3 76,1.. x 2' 2,50 2.63 3,25 5,62 4,00 1.87 M10 x 57 4.1 5,9 63,5 66] 82.6 142] 10.1,6 47.5 1.9 2.7 3'x1W 1.75' 1.88 3,34 6,13 3,32 2.21 '/z'x3' 3,9 4,9 44,5 47.6 84.8 155] 84,3 56.1 M12x76 1,8 2,2 3'x 1'h' 2,00 2.13 3,38 6,13 3,56 221 'It' x 3' 4,2 5,5 50..8 54.0. 85,9 155] 90.4 56,1 M12x76 1,9 2,5 3'x2" 2,50 2,63 3.50 6,13 4,09 2,21 'l,x3' 4.7 6,5 63,5 66] 88,9 155] 103.9 56,1 M12x76 2.1 2,9 4"x 1'1, 1.75' 1,88 3,92 7,13 3,32 2,78 'lz'x3' 5,5 7,1 44,5 47.6 99,6 181.1 84.3 70.6 M12 x 76 2.5 3.2 4' x 1'1, 2.00 2,13 4,00 7,13 3,56 2.78 'lz'x3' 5,5 7,1 50.8 54,0. 10.1,6 181,1 90.4 70..6 M12x76 2,5 3.2 4"x 2' 2,50 2,63 4,00 7,13 4,06 2.78 '/z'x3' 6,0 8,1 63,5 66.7 10.1,6 181,1 10.3.1 70.,6 M12x76 2] 3] 4'x2'1z' 2,75 2.88 4,00 7,13 4,38 2.78 'h'x3' 6,0 8,1 69,9 73,0. 10.1,6 181,1 111.3 70.6 M12x76 2.7 3] 4" x 76,10.. 2.75 2,88 4,00 7,13 4,38 2,78 M12 x 76 6,0 8,1 69.9 73,0. 10.1.6 181,1 11/,3 70.6 2.7 3.7 4"x3" 3,50 3,63 4,13 7,13 5,13 2.78 'h'x3' 7.0 13,5 889 92,1 104,9 181,1 130.,3 70.,6 M12x76 3.2 6,1 5'x 1'1, 2,00 2,13 4,63 8,13 3,56 3.37 'fa' x 4'14 6,5 7.7 50.,8 54,0. 117.6 206.5 90..4 85,6 M16x 121 2,9 3,5 5"x2" 2,50 2,63 4,63 8,13 4,06 3,37 'fa'x43/, 7,1 8,1 63,5 66.7 1116 20.6.5 103.1 85.6 M16x 121 3.2 3.7 5'x2'Ii 2.75 2,88 4,75 8,13 4,38 3,37 'I. x 4'/4 7,3 8.7 69.9 73.0. 120..7 206,5 111,3 85,6 M16x121 3.3 3.9 Figure 730 Mechanical Outlet Grooved Cross Nominal Hole Dia,; Nominal Dimensions Boll Tee Cross Size Hole Max. A B C E Size" Net WI. Net WI, Runx Inches Inches Inches Inches Inches Inches Lbs, Lbs, Branch mm mm mm mm mm mm Dia, x Lg, Kg. Kg. 5' x 76,1.. 2,75 2,88 4.75 8,13 4,38 3,37 M16x121 7,3 8.7 69,9 73,0. 120.] 206,5 111.3 85,6 3.3 3,9 5'x 3' 3.50 3,63 500 8,13 5,13 3,37 'ls"x43t.' 7,6 14.7 88,9 92,1 127.0. 206,5 130.,3 85,6 M16x 121 3.4 6] 165,1"",x1W 2.00 2,13 5,13 9.25 3,56 3,90 M16x121 6.9 7,9 50..8 54,0. 130.,3 235.0. 90.4 99,1 3,1 3,6 165,1"""x1'h' 2,00 2,13 5,13 9.25 3.56 3,90 M16 x 121 7.4 8,9 50.8 54,0. 130..3 235.0. 90.4 99,1 3.4 4,0. 165.1mmx2' 2.50 2,63 5,13 9.25 4.06 3,90 M16 x 121 7,5 8.9 63.5 66] 130..3 235,0. 10.3,1 99.1 3.4 4,0. 165,1"" x 2'12' 2.75 2,88 5,13 9.25 4.38 3,90 M16x121 7,5 11.1 69.9 73,0. 130.3 235,0. 111.3 99,1 3.4 5.0. 165,1~.x76,lh. 2.75 2,88 5.13 9,25 4.38 3,90 M16x121 7,5 11,1 69,9 73,0. 130..3 235.0. 111.3 99,1 3.4 5.0. 165,1"",x3' 3.50 3,63 5,50 9,25 5,13 3,90 M16x121 9,5 14,1 88,9 92,1 139.7 235.0. 130..3 99.1 4,3 6.4 165,1"" x4' 4.50 4,63 5,38 9,25 6,13 3,90 M16x121 10,0 20,1 114.3 117,5 136] 235,0. 155] 99,1 4,5 9,1 6'x1'1<' 2.00 2,13 5,13 9.25 3,56 3,90 la'x43f<' 6.9 7,9 50.,8 54,0. 130.3 235.0. 90.4 99.1 M16x 121 3.1 3,6 6' x 1'h' 2.00 2,13 5,13 9,25 3,56 3,90 la'x43f<' 7,4 8,9 50.8 54,0. 130..3 235,0. 90.4 99.1 M16x121 3.4 4,0. 6'x2' 2,50 2,63 5,13 9,25 4,06 3.90 'I,' x 41, 7,5 8.9 63.5 66] 130.3 235.0. 103,1 99.1 M16x 121 3.4 4,0. 6'x2'/2' 2.75 2,88 5,13 9.25 4,38 3,90 la'x431/ 7,5 11.1 69,9 73,0. 130..3 235,0. 111,3 99,1 M16x 121 3.4 5,0. 6'x76,1"" 2.75 2,88 5,13 9,25 4,38 3,90 M16x121 7,5 11.1 69.9 73,0. 130.,3 235.0. 111.3 99,1 3.4 5,0. 6'x3' 3,50 3,63 5,50 9,25 5,13 3,90 '/a'x41, 9,5 14,1 88.9 92,1 139.7 235,0. 130.,3 99,1 M16x121 4,3 6,4 6'x4' 4.50 4,63 5,38 9.25 6,13 3,90 'fa'x431/ 10,0 20,1 114,3 117.5 136.7 235.0. 155] 99,1 M16x 121 4,5 9,1 8'x2'1, 2.75 2,88 6,25 12,50 4,38 4.90 3/, x 43// 10.2 12,1 69,9 73,0. 158.8 317.5 111.3 124.5 M2o.x121 4,6 5,5 lr x 76,1mm 2,75 2,88 6,25 12,50 4,38 4,90 M20 x 121 10,2 12,1 69.9 73,0. 158,8 317.5 111.3 124,5 4,6 5,5 lr x 3' 3.50 3,63 6,50 12.50 5.13 4,90 '1/ x 43/, 12.5 15,1 88,9 92,1 165.1 317.5 130.,3 124.5 M2o.x 121 5.7 6,8 8'x4' 4,50 4,63 6,38 12.50 6,13 4,90 31/x431/ 12,5 21,1 114,3 117.5 162.1 317.5 155.7 124.5 M2Dx 121 5.7 9,6 ~ Proper hole preparation is required for effective sealing and performance. Cheek the pipe seal surface within 'Ia' of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly. proper seating of fhe locating collar or ffow Irom the outlel. Check gasket grade to be certain it is suitable for the service, For crosses, ensure doubte outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe. such as dry pendents. etc. may not be compatible with the female threaded outlet on the Mechanical Tee, Always confirm compatibility by contacting Tyeo Fire Products, a. Gold color coded metric bolt sizes are available upon request. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded, Always read and understand the installation instructions (IH.1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system, Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Certified Company Printed U,S,A, ".._.,._"~"".._~~c_-._"",_~~."~,.,,,,, -""'",-~'"--~>"~_-'<____'~'_<'_~_'~"'_"'~___"~"~~'_'._._.,...",._.~....__._-,.~", . tqco / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 71 Flange Adapter General Description [lPCB) [VdS] ~ See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approval Information The 71 Flange Adapter allows a direct transition from flanged components into a grooved piping system. Flange bolt patterns conform to ANSI Class 125 and 150 standards and PN16 as indicated. WARNING The Figure 11 Flange Adapter described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device, The owner is responsible for maintaining their fire protection system and devices in proper. operating condition, The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Figure: 71 Sizes: 2" - 12' Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing / Approval information, Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: · Non-lead orange paint . Fire brigade red (optional) non-lead paint . Hot dipped galvanized conforming to ASTM A-153 Gasket: (specify when ordering) . Grade "E" EPDM, green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e,g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected, It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service, September 2004 Limited Warranty Products manufactured by Tyco Rre Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Rre Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwith Tyco Rre Productsorfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Rre Protection Association (NFPA), ancl/orthe standards of any other Authorities Having Jurisdiction. Materials found by T yco Rre Products to be defective shall be either repaired or replaced, at T yco Rre Products' sole option. T yea Rre Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. T yco Rre Products shall not be responsibleforsprinklersystem designerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyer'S representatives, IN NO EVENT SHALL TYCO fIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES,INCLUDINGBUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCOFlREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TFP1880 Page 2 of 2 TFP1880 Figure 71 Flange Adapter Gir r'fF BED L~- A Figure 71 ANSI Calss 125 and 150 Pipe Max t Max t Nominal Dimensions Bolts + Net Nominal 0,0, Pressure End Load A B C *0 *E F WI. Size Inches psi Lbs, Inches Inches Inches Inches Inches Inches Size Oty, Ibs. Inches mm kPa N mm mm mm mm mm mm Oia. x Lg. kg 2.375 250 1,107 6.38 4,75 0,75 2,38 3.41 7.25 3.0 2 60.3 1,724 4,924 162.1 120,7 19,1 60.5 86,6 184.2 5/e' X 3' 4 1.4 2.875 250 1,622 7.00 5,50 0.88 2,88 3.91 7,88 5.0 2'/2 73.0 1,724 7,215 178.0 140.0 22.0 73,0 99.0 200,0 5/e' X 3" 4 2.3 3,500 250 2,404 7,50 6.00 0,94 3.50 4,53 9.88 5.6 3 88.9 1,724 10,693 190.5 152.4 23.9 88.9 115.1 251.0 5/e' X 3" 4 2.5 4,500 250 3,974 9.00 7,50 0,94 4,50 5,53 9.90 7.0 4 114.3 1,724 17,676 228.6 190,5 23.9 114.3 140,5 251.5 5/8" x 3" 8 3.2 5.563 250 6,073 10.00 8,50 1,00 5.56 6,72 11,38 9.2 5 141.3 1,724 27,013 254,0 215.9 25.4 141.2 170.7 289,1 3/4' x 3'/2' 8 4.2 6,625 250 8,614 11.00 9,50 1.00 6.62 7.78 11,88 10,0 6 168.3 1,724 38,315 279.4 241.3 25.4 168,1 197.6 301.8 3/.' x 3'/2' 8 4.5 8.625 250 14,599 13.50 11,75 1.13 8.62 9.94 14.38 16.6 8 219,1 1,724 64,936 342.9 298.5 28.7 218,9 252,5 365.3 3/4" x 3'/2' 8 7.5 10,750 250 22,679 16.00 14.25 1.19 10,75 12.31 16.88 21.8 10 273.0 1,724 100,876 406.4 362.0 30.2 273.1 312.7 428,8 1/e' X 4' 12 9.9 12.750 250 31,903 19,00 17.00 1.25 12.75 14,31 20.00 24.2 12 323.9 1,724 141,905 482.6 431.8 31.8 323.9 363.5 508,0 1/e' X 4" 12 11.0 Figure 71 PN16 Pipe Maxt Maxt Nominal Dimensions Bolts + Net Nom.Size Pressure End Load A B C *0 *E F WI. Inches 0.0, Lbs. Inches Inches Inches Inches Inches Inches Size Oty. Ibs. mm mm Bar N mm mm mm mm mm mm Dia. x Lg. kg 2" 1,028 6,38 4,92 0.75 2.38 3.41 7.25 3,0 50 60,3 16 4,573 162,1 125.0 19.1 60.5 86.6 184.2 M16 x 76 4 1.4 2'/2" 1,640 7,28 5.71 0,88 3,00 4.03 8,09 5,6 65 76.1 16 7,295 184,9 145.0 22.4 76,1 102.4 205.5 M16 x 76 4 2,5 3" 2,232 7,88 6.30 0,94 3,50 4,53 8,75 6.6 80 88.9 16 9,928 200.2 160,0 23,9 88.9 115.1 222,3 M16 x 76 8 3.0 4" 3,690 9,00 7,09 0,94 4,50 5,53 9,90 7.0 100 114,3 16 16,413 228.6 180.1 23,9 114,3 140.5 251.5 M16 x 76 8 3.2 5" 5,512 9.84 8,27 1.00 5,50 6,53 10.69 9,2 125 139.7 16 24,517 249.9 210.1 25.4 139.7 165.9 271.5 M16 x 89 8 4.2 6" 7,698 11,25 9.45 1.00 6.50 7.53 12.12 10.0 150 165,1 16 34,241 285,8 240.0 25.4 165,1 191.3 307.8 M20 x 89 8 4.5 6" 7,997 11.00 9.49 1.00 6.62 7.78 11.88 10,0 150 168,3 16 35,571 279.4 241,1 25.4 168.1 197.6 301,8 M20 x 89 8 4.5 8" 13,555 13.38 11,61 1,13 8.62 9.94 14.31 16,6 200 219.1 16 60,293 339.9 294.9 28.7 218,9 252.5 363.5 M20 x 89 12 7.5 10 21,057 16.00 13.98 1.19 10,75 12,31 16,88 21.8 273.0 273,0 16 93,662 406.4 355.1 30,2 273.1 312.7 428.8 M22 x 102 12 9.9 12' 29,621 18,12 16,14 1.25 12.75 14.31 19.19 28.0 300 323.9 16 131,754 460.2 410.0 31.8 323.9 363,9 487.4 M24 x 102 12 12.7 t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness, Contact Tyco Fire Products for details, See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings, * Dimensions D and E represent minimum and maximum sealing surfaces, + Bolts and Nuts are not supplied, Bolt lengths are standard; it is the responsibility of the purchaser to verify correct length for the intended application, General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded, Always read and understand the installation instructions (IH-1 000), Never remove any piping component or correct or modify'any piping deficiencies without first depressurizing and draining the system, Material and gasket selection should be verified to be compatible for the specific application, TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Certified Company Printed U,SA . -tl/CO / Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Descriptio~,__ - /<../'-- ,( (VdS] '... " ~ tiii:' If'i.C\ See Fire Protection \:!.Y~~ Submittal Sheet for ~ Pressure Rating and Listing/Approval Information The Figure40-5 Strap isan economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time, The 40-5 Strap may be used in wet, dry pipe and deluge systems, WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction, Failure to do so may impair the performance 01 this device, The owner is responsible for maintaining their fire protection system and devices in proper operating condition, The installing contractor or sprinkler manufacturer should be contacted with any Questions, Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing / Approval information, Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: · Clear rust inhibitive coating . Zinc electroplated conforming to ASTM B-633, Type III Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) . Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the Quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S" Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e,g,. NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any Questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a Qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Rre Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Rre Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwith Tyco Rre Productsorfor products and components which have been SUbject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Rre Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Rre Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Rre Products shall not be responsible forsprinkJersystem designerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAlDAMAGES,INCLUDINGBUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCORREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN liEU OF ANY AND AU OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUlAR PURPOSE. TFP1720 Page 2 of 2 TFP1720 Figure 40-5 Strap c Pipe Nominal Dimensions Hole Net Size A B C D Size Wt. Run x Inches Inches Inches Inches Inches Lbs, Branch mm mm mm mm mm Kg. 1'/4" x '/2" 2.00 1,50 3,50 1,20 13/,6 0,84 50.8 38.1 88.9 30.5 30.2 0.4 11/4" x 3/4" 2,00 1,50 3.50 1,20 10/'6 0.88 50.8 38.1 88.9 30.5 30.2 0.4 1'/4" x 1" 2.31 1,68 3.50 1.20 13/,6 1.13 58.7 42.7 88.9 30.5 30.2 0.5 1'12" x '12" 2,12 1.62 3,50 1.32 10/16 0,84 53.8 41.1 88.9 33.5 30.2 0.4 1'12" x 3/4" 2,12 1.62 3,50 1,32 10/'6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1'12" x 1" 2.43 1,80 3.50 1.32 13,;'6 1,13 61.7 45.7 88.9 33.5 30.2 0.5 2"x'12" 2,36 1.86 3.74 1,55 10/,6 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2" x 3/4' 2,36 1.86 3.74 1.55 13/,6 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" x 1" 2.67 2,04 3.74 1.55 1 0/,6 1,16 67,8 51.8 95.0 39.4 30.2 0.5 2'12" x '12" 2.61 2.11 4,25 1.80 10/16 0,90 66.3 53.6 108.0 45.7 30.2 0.4 2'12" x 3/4" 2.61 2.11 4,25 1,80 10/,6 0,99 66.3 53.6 108.0 45.7 30.2 0.4 2'12" x 1" 2.92 2.29 4.25 1.80 13/,6 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Equivalent Length Size (1 inch pipe) 1'/4" x 1" 8 1'12" x 1" 6 2" x 1" 6 2'12" x 1" 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe, The 1 inch outlets can be used with a nipple leading directly to a sprinkler, These fittings should be used for hydraulically calculated systems only, Note: Outlet threads conforming to ISO 7-1 are available, contact Tyco Fire Products. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded, Always read and understand the installation instructions (IH-1000), Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Certified Company Printed U,SA C.I. THREADED ,FITTINGS ~@<@> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL. ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PERASTMA126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 816.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME 816.14. THREADS ARE NPT PER ANSI/ASME B1.20.1. /'".- 8 -"/ NOM INAL ITEM MAX. DIM ENSIONS WBGHT SIZE CODE WORI<ING EACH (INCH) 1# P.S,I, A B PIECE 1 CB90033 300 1.50 1.50 0,95 11/4 CB90044 300 1.75 1,75 1.34 1112 CB90055 300 1:94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 2112 CB900n 300 2.70 2.70 4,75, CAST IRON RED. COUPLING ~ NOM lNAL ITEM MAX. DIM B-ISION WBGHT SIZE CODE WORI<ING EACH (INCH) 1# P.S.I. A PIECE 1Xl/2 CRC031 300 1.70 0.62 1X3I4 CRC032 300 1.70 0,80 NOMINAL ITEM MAX. DIM ENSIONS WBGHT SIZE CODe WORI<ING EACH (INCH) , P,S.I. A B PIECE 1X1/2 CB90031 300 1.26 1.36 0,64 1X3J4 CB90032 300 1.37 1.45 0,87 1 1/4Xll2 CB90041 300 1.34 1.53 0.96 1 1/4X3I4 CB90042 300 1.45 1,62 1,13 1 1/4Xl CB90043 300 1.58 1,67 1.16 1 1l2Xl 112 CB9D051 300 1.41 1.66 1.17 1 112x3l4 CB90052 300 1.52 1.75 1.28 1 112Xl CB90053 300 1.65 1.80 1.51 1 l/2Xl 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3J4 CB90062 300 1,60 1.97 2.05 2Xl CB90063 300 1.73 2.02 2.10 2Xll/4 CB90064 300 1.90 2,10 2.30 2X1 1/2 CB90065 300 2.02 2,16 2.60 Page 38 CAST IRON STRAIGHT TEE ~ NOMINAL lTat MAX. DIM ENSIONS WBGHT SIZE CODe WORI<ING EACH (INCH) , P,S.J. A B PIECE 1 CT333 300 1,50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 1112 CT555 300 1,94 1,94 2.51 2 CT666 300 2,25 2.25 3.96 21/2 CT777 300 2.70 2.70 6.45 CAST IRON 45 DEGREE ELBOW ~ NOMINAL ITEM MAX. DIM ENSIONS WBGHT sIze CODE WORI<ING EACH (INCH) , P.S.t A B PIECE 1 CB45033 300 1,12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 CB45055 300 1,43 1,43 1,80 2 CB45066 300 1.68 1.68 2.79 ---r A ___1 CAST IRON PLUGS ~- NOMINAL ITEM MAX. DIM ENSION WBGHT SIZE CODe WORI<ING EACH (INCH) , P,S.I. A PIECE 1/2 CPLOOl 300 0,94 0.10 3/4 CPlO02 300 1.07 0.17 1 CPL003 300 1,25 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 t- p C.I. THREADED FITTINGS ~ @<8> LISTED LISTED APPROVED For fire protection seNices request submittal GRS 1,3 CAST IRON CROSS ~ -- - - - - NOM INAL ITEM MAX. DIM ENSIONS WBGtrr I SIZE CODE WORKING EACH (INCH) 1# P.S.L A B PIECE 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1,75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 .4.00 11/4X1 CX043 300 1,58 1.67 2,05 11/2X1 CX053 300 1.65 1,80 2.40 2X1 CX063 300 1,73 2.02 2.75 CAST IRON REDUCING TEE ~-- -~ r NOMINAL SIZE (INCH) 'lXIXl/2 1X1X314 Xll2X' 1~~4 1 1 12 n74 ~/2 1174 'iX 4 =fiB : 1 '4X1 4)11/2 1 '4Xl r41l 1/4 1 /4X1/4Xl lXl iX11r.l 1 1/4X' 1/4X2 1 lr.lX1A 1 4 1 11 1/4 1 12 1 1 1/4xll2 1 :1 1/4X3/4 1 1 Cn/4X1 1 1/2x11/4x1 1/4 1 1/2x1.1/4xl 1/2 1 l/2Xl 1/4X2 1 l/2Xl 1/2X1/2 1 1/2X1 1/2X3/4 1 l/2Xl l/2Xl 1 1/2X1112X11/4 1 1/2Xll/2X2 2X1X2 2Xl 1/4X2 2X1 1/2X1/2 2Xl 1/2X3I4 2X1 l/2Xl 2Xl1/2Xl1/4 2X1 l/2Xl 1/2 2Xll/2X2 2X2X1/2 2X2X3/4 2X2Xl 2X2X11/4 2X2X1 1/2 2x2x21/2 ITEM CODE # G r331 C r332 C' 3'13 C 323 ~. 334 G r335 G '431 C '432 l; '433 C 434 l; C G C G C' 4 6 l; I:>>; CT532 G '533 C 534 G 3 C 4 C' C CT54~ CT545 CT546 CT551 CT552 CT553 CT554 CT556 CT636 CT646 CT651 CT652 CT653 CT654 CT655 CT656 CT661 CT662 CT663 CT664 CT665 CT667 MAX. DIM elSlONS WORKING P.S,L A 300 1,26 300 1.3 300 1.5D 300 UO 300 1.6 -'300 "l.8 300 1,3 300 1. 300 l.5 300 1.7 300 1.8 300 1.34 300 1,45 300 1.58 30U 1.1111 300 2.10 300 .41 300 ,52 300 .6 300 .82 300.9, 300 .4 300 .5: 300 .6! 300 .82 300 1,94 300 2.16 300 1.41 300 1.52 300 1,65 300 1.82 300 2.16 300 2,25 300 2.25 300 1.49 300 1.60 300 1,73 300 1,90 300 1,49 300 2.25 300 1.49 300 1.60 300 1,73 300 1,90 300 2,02 ~on 2.60 B C 1.2 1.36 .3 1.45 .3 1.50 .4 1.50 ,& .58 .8 ,6 , .3 ,51 .5 .6 1.75 .8t 1.82 .34 1,53 .45' .6 .58 .6 .1111 Jl:r 2.10 .90 1.34 1.37 1.7 .5 1. 1,6 1,8 1. 1.9 1 ,66 1. ,75 1. 8 .80 1.75 .88 1.88 1.94 2.10 2.02 1.41 1.66 1,52 1.75 1.&5 1.80 1,82 1.88 2.16 2.02 2,02 2.25 2,10 2.25 1.41 1.88 1.52 1.97 1.65 2.02 1.82 2.10 1,41 1.88 2.16 2.25 1.49 1.88 1,60 1,97 1.73 2.02 1.90 2.10 2.02 2.16 260 2.39 I WBGHT EACH PIECE lJJilJ 1, O. ,18 . 8 .2 . 3 .7 , 8 . 7 1.8~ 2, 1, T. 1. 2.21 2-:55 1,41 1.65 ~ 2.00 2.30 1. 8 1.2 1 15 2!2' 2.45 2.80 1.76 1.87 1.94 2.29 3,28 3.40 2.80 2,09 2.40 2.54 2.85 2.24 3.75 2.60 2.71 2,97 3.32 3.72 5:10 Page 39 OJ. THREADED FITTINGS ~ @<@> LISTED LISTED APPROVED For fire protection services request submillal GRS 1.3 DUCTILE IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 500 PSI SERVICE: DUCTILE IRON PER ASTM A 536 GRADE 65-45- 12, DIMENSIONS CONFORM TO ANSI B16.3 CLASS 150. THREADS ARE NPT PER ANSVASME B1.20.1 NonCE: DUCTILE IRON FmlNGS HAVE HIGHER TENSILE STRENGTH THEN THAT OF STEel PIPE. THEREFORE, OVER TIGHTENING CAN CAUSE DAMAGE TO PIPE THREADS WHICH MAY CAUSE LEAKAGE. DUCTILE IRON FmlNGS SHOULD BE TIGHTENED THREE TURNS BEYOND HAND TIGHT, BUT NO MORE THAN FOUR TURNS. NOMINAL ITEM MAX. D1Mes/ONS WBGHT SIZE CODE WORKING EACH (INCH) , P.S.I. A B PIECE 1 0845033 500 1.12 1.12 0,46 11/4 0845044 500 1.29 1.29 0.73 NOMINAL ITEM MAX. DlMeslONS WBGHT 11/2 0845055 500 1.43 1.43 0.92 2 0845066 500 1,68 1.68 1.50 SIZE CODE WORKING EACH (INCH) 1# P.S.J. A B PIECE lXl12 0890031 500 1.26 1.36 0,44 lX3f4 0890032 500 1.37 1,45 0.52 1 1/4Xl/2 0890041 500 1.34 1.53 0.64 1 1J4X3f4 0890042 500 1,45 1.62 0.72 11/4Xl 0890043 500 1.58 1.67 0,75 1 l/2Xl DB90053 500 1.65 1.80 0.92 1 l/2Xl 1/4 DB90054 500 1.82 1.88 1.08 NOMINAL ITEM MAX. DlMelS/ONS W8GHT 2Xl/2 DB90061 500 1,49 1.88 1.08 SIZE CODE WORKING EACH 2X3f4 DB90062 500 1,60 1.97 1.24 2Xl 0890063 500 1.73 2.02 1.40 (INCH) II P,S.I. A B PIECE 2Xl 1/4 0890064 500 1.90 2.10 1.52 1 DT333 500 1.50 1.50 0.85 2Xl 1/2 DB9OO65 500 2.02 2.16 1.65 11/4 DT 444 500 1.75 1,75 1.22 11/2 DT555 500 1.94 1,94 1,55 ~ 2 DT666 500 2.25 2,25 2,45 L_,., "','--"7 I . NOMINAL SIZE (INCH) 1 11/4 11/2 2 ITEM CODE 1# DB90033 0890044 DB90055 DB90066 MAX. WORKING P.S.I. 500 500 500 500 DIMENSIONS WBGHT EACH PIECE ,0.62. 0.90 1.20 1.85 A 1.5(J 1.75 1.94 2.25 B 1.50 1,75 1,94 2.25 f-- 8--l ! i DUCTILE IRON COUPLING -._~ NOMINAL lTed MAX. DIM ENSION WBGHT SIZE CODE WORKING EACH (INCH) II P.S.I. A PIECE 1 DCL033 500 1.67 0.40 11/4 DCL044 500 1.93 0.57 11/2 DCLOSS 500 2.15 0.75 2 DCL066 500 2,53 1.15 Page 40 DUCTILE IRON 45 DEG, ELBOW -~ NOMINAL ITEM MAX. W8GHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE lXl/2 DRC031 500 1.69 0,39 lX3I4 DRC032 500 1.69 0.53 ..-----r I I o ..J.. 1----"- c ,__..i I '1- 8 T J.. r--o----i .il.i~ ! 1 INSIDE HEAD ~l-'~~: . ., ~. ~ -1 :. '... ..;~;~~1 .. -- - . . _H OUTSIDE HEAD . NOMINAL ITEM DIMENSIONS SIZE CODE (INCH) I lxll2 DBUSH31 0.75 0.25 1.42 OUT 0,22 lx314 DBUSH32 0.75 0.25 1.42 OUT 0.17 11/4x1 DBUSH43 0.80 0.28 1.76 OUT 0.28 1 l/2xl DBUSH53 0.83 0.31 2.00 OUT 0.44 1 1/2xll/4 DBUSH54 0.83 0.31 2.00 OUT 0.30 2x1 DBUSH63 0.88 0.41 1.95 IN 0.66 2xl 1/4 DBUSH64 0.88 0.34 2.48 OUT 0.72 2xl 1/2 DBUSH65 0,88 0,34 2.48 OUT 0.61 A B wr. STYLE C EACH . 0.1. THREADED FITTINGS I} ~ @<8> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 DUCTILE IRON REDUCING TEE -- - -~---- - --- ----~-- -- - -- NOMINAL SIZE (INCH) 1 X1X1J 1X'tX3J -= (1 [1 1 '4 11,112 1 1 4 1114XfXl 11/41(1 11/4 1 II~ 1(1),11/2 ln 11:4XU2 1 1/4J .1 1 IX3I4 ~~n (1 nXl I II 1/4;(1112 H l11J4X2 = 1172X1Xl14 1 1 112Xl 1/4Xll2 112X1~ 1rDll1/4Xl 1rDl1 1/4-'" -:;~1I2X112 -1im17mJ4 1 112Xf1'i2X1 t1'172Xrli'2X1 U4 1T172X1172X2 2)(1)(2 ~2Xl1 4 (1 1i: 8lIi4 ~ 2X2Xl1/4 2J{;lJl'l , /2 2X2X2 172 ~ DUCTILE IRON CROSS ~------~----- - ---- NOMINAL ITEM MAX. DIMENSIONS WBGHT SIZE CODE WORKING EACH (INCH) # P,S.I A B PIECE 1 DX033 500 1.50 1,50 0,98 11/4 DX044 500 1.75 1.75 1.50 11/2 DX055 500 1,94 1.94 1.90 2 DX066 500 2.25 2.25 2.95 11/4Xl DX043 500 1.58 1.67 1.27 1 ll2Xl DX053 500 1.65 1.80 1.48 2Xl DX063 500 1.73 2,02 2,10 ITEM CODE :m- OT riD" 1'313 r323 i334 = "433 == f. rj r531 r532 r533 534 r53li 541 == OHi35 DT646 DT651 DT652 DT653 "M'654 I1I1l55 rr656 e DT665 DT667 DT762 MAX. WORKING P,S.I, 500 500 500 500 DDO 500 500 500 500 500 -500 500 500 500 ,500 500 500 500 500 500 500 500 500 -500 500 500 DOO 500 500 -500 500 500 500 500 500 500 lOO liDO SOD 500 500 500 500 500 500 1. 1. 1.75 1.88 1.34 1,45 1.58 1.18 2,0 Lll 1, 2 1, ,5 1.82 1.9 1.4 1.5 ,6 ,1 1.41 -:52 .65 .82 2:16 2.25 2.25 1.49 1.60 1,73 1,90 2'])2 2.25 1.49 1,60 "1.73 1.90 2.02 2.60 "1.74 DIMENSIONS A 1.2 1.3 .8 : 0 1. 1. 2 1.65 1.8 2':16 - 2.02, 2.10 lAt- 1.52 1.65 -1.82 1.94 2.16 1.49 1,60 1.73 1.90 2,02 2.60 1.60 B .2 ,3 ,3 ,4 .6 1.80 1.26 1.37 1.50 1,67 l,IIU 1.34 1.45 1.58 1, III 2. 0 C 1.36 1.45 1.50 1.50 1.58 1.65 1.53 1.62 U 1.7 1. 1, . .90 .f .7 .8 1.8 1.9 1.66 .75 1.80 !.02 .16 1.15 1.80 1.88 2Jr2 -2.25 2.25 1.88 1.97 2.02 2.10 2,11J 2.25 1.88 '1,97 2.02 2.10 2.16 2.39 2.32 ~... _ ~l-:m~ '~/.l""~"""-'~~ _ ~:; ~ -"< 'I ' > ',P,: !L., , " .";:,~ ~,r;~,,"_ -._ ~:~~"~J_~:-~f~ W8GtfT I EACH PIECE 0.64 0.73 0.71 0,76 0,18 1.16 0.112 O.! 0 1,00 1.08 1.42 0,86 0.92 0.95 1.45 1,75 0.95 1.14 1.17 1.34 1.45 1.05 1.15 1.25 1.90 1.15 1.24 1.30 1.48 1.98 2~15 2.30 1.50 1.62 1.64 1.80 2.00 2.35 1.60 1.68 1,85 2,04 2.18 3.61 2.28 I It. DUCTILE IRON CAl-' NOMlNAL- -1-- -lTed- -- SIZE CODE (INCH) # 1 DCP003 1 1/4 DCP004 1 1/2 DCP005 2 DCP006 - I MAX. WORKING P.S.I. 500 500 500 500 DIMENSION I W8GtfT I EACH A PIECE 1,16 0.32 1,28 0,43 1.33 0.60 1.45 0"91 ,_.._--_..,~---'".._,-~~~-"'"....._'_._.,-~._.....,."._..--.-".-,"" Page 41 MERIT MANUFACTURING CORPORATION 319 CIrcle of Progress' Pottstown, PennsylvanIa 19464-3811 Tel 610-327-4000 . Fax 610-970-9282 Fax Toll Free 800-543-7013 · www.meritmfg,com MERIl: SUBMITTAL SHEET Merit Weld-Mlser™ Tee-Lel~ Welding Outlel Finings Merit Weld-Mlsel'rM Tee.tet. Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifi- cally designed and manufactured to be Installed on schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe, Merit Tee-Lets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTMA 53, Grades A or B, Type E, Tee:-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing' a single pass with mini- mum bum-through and pipe distortion. Weld Miser Tee-lets are recommend- ed for use on proprietary thin wall, schedules 5, 10 and 40 pipe. Threads comply with ANSI 81,20.1 or 1807/1. They are UL Usted and FM Approved for use conforming to the requirements of 8ulletin 13 1999 of the National Fire ProtecUon Association, When used in fire sprinkler systems, Tee-lets are rated for 300 psi, When used in mechanical systems, maximum pressures are calculated using criteria developed for ASME 831 pIping code, Send for details If required. c@ usrm IFIl~UW IMIllDllllDllD $1foll.1/il1I APPROVED PRODUCT APPROVALS Tee-Let Welded Outlet Fitting (UL VIZU - EX3788, FM Approval Guide Chapter 1 - Pipe Fittings) Outlet Outlet PI~e Size Header P\f1e Size Rated Pressure Model (Jne ) (Ine ) (pslg) Tee-let Type A *~1 * - 8 (Sch. 10 40) 300 (F-Threaded End) 11/4 1* 2 2'h 3 4 * - 4 ISch. 5 DvnaFlow) 2 4 (El-FIow) 24 6 (El-Aow\ Tee-Let Type C 11/4 - 8 1114 - 8 (Sch. 10 40) 300 (Grooved End) 2*- 8 * .. 4 (Sch. 5 DvnaAow) Tee-Let Type C1R 1~ - 6 1 ~ - 8 (All Schedules) 300 (Roll Grooved End) 1) Size on size (ie 2 x 2) Tee-Lets are not FM Approved 2) FM rated working pressure when welded on 5ch. 5 or nonlhreadable lighlwell pipe is 175 psi. PROJECT: ARCHITECT J ENGINEER: CONTRACTOR: ADDRESS: APPROVAL: PHONE: NOTES: PAGE 1 OF 4 Merit Weld-Miser Tee-Let Welding Outlet Fittings Pilt Hqm~er '85PT, "l!p"~I, ' ',OuU" .Iii~' , 1002002 1/4 x - 6x 1005012 112 x - 13x 1005015 . 1005020 1005025 1007012 3f4 x - 19 x 1007015 1007020 1007025 1010012 1 x 1110012 25 x 1010015 1110015 1010020 1110020 1010025 1110025 1010030 1110030 1010050 1110050 1012012 1-1/4 x 1112012 32 x 1012015 1112015 1012020 1112020 1012025 1112025 1012030 1112030 1012050 1112050 1015015 1-1/2 x 1115015 40 x 1015020 1115020 1015025 2.1/2 1115025 1015030 1115030 1-1/4 - 8 6 - 200 1.-1/4 -1-112 32 - 40 1-112 - 2 40 - 50 2 - 2-112 50-65 2-1/2 - 8 65 - 200 1-1/4 - 1-1/2 32 . 40 1-1/2 - 2 40 . 50 2.2-1/2 50.65 2-1/2.8 65 - 200 1-1/4.1-1/2 32 - 40 1-1/2 - 2 40 - 50 2 - 2.1/2 50 - 65 2-1/2 - 3 65 - 80 3-4 80.100 5-8 125 - 200 1.1/4 -1.1/2 32 - 40 1-1/2 - 2 40 - 50 2 - 2-1/2 50 . 65 2-1/2 - 3 65.80 3.4 80.100 5-8 125.200 1-1/2 40 2 50 1.625 65 3-4 80 - 100 Type A Female Thread t c t ------- ---l--- I~D~I I _._._._._._._._._i_._._._._. B -.-.- __________j________t__ I "'JlI~11 QQ~lr ' ~. ORUti" IilJld,-, ",,~~'i,' vI.i.Ill" 'hrl,: ::'~/f..ilIi.il uiliil O'tiii"'iJ ' - 'In' !lIlIi!li,i ... . ;~il S~~ 'Sia~1t ',. '5Jl~.,~,;,'.~~,t,',~:. """.. .$P.T.llzd . 1~.l"'Il1, .' , . :' " , ' 'Il,!iiiii, Hiiller ' ~iii:j , 1.063 27.0 1.063 27.0 1.063 27.0 1.063 27.0 1.125 28.6 1,125 28,6 1.125 28.6 1.125 28.6 1.250 31,8 1.250 31.8 1.250 31.8 1.250 31,8 1.250 31.8 1.250 31,8 1.375 34.9 1,375 34.9 1.375 34.9 1.375 34.9 1.375 34.9 1.375 34.9 1.625 41.3 1.625 41.3 1.610 41.3 1.625 41,3 0,700 17.8 0,700 17.8 0.700 17.8 0.700 17.8 0.900 22.9 0,900 22.9 0.900 22.9 0.900 22.9 1.145 29,1 1.145 29,1 1.145 29,1 1.145 29,1 1,145 29.1 1.145 29.1 1.490 37.8 1.490 37.8 1.490 37.8 1,490 37,8 1.490 37.8 1.490 37.8 1.610 40,9 1.610 40.9 0.875 40.9 1.610 40.9 0.500 12.7 0.500 12.7 0.500 12.7 0.500 12.7 0.500 12.7 0,500 12.7 0.500 12.7 0.500 12.7 0,500 12.7 0,500 12.7 0.500 12.1 0,500 12.1 0.500 12.7 0.500 12.7 0.500 12.7 0.500 12.7 0.500 12,7 0,500 12,7 0,500 12.7 0.500 12,7 0.875 22.2 0,875 22.2 0.477 22.2 .022 0.875 0.477 22,2 ,022 0.080 0.04 0.171 0.08 0.171 0.08 0.171 0,08 0.169 0.08 0.260 0.12 0.260 0.12 0.260 0.12 0.256 0.12 0,331 0,15 0.331 0.15 0.320 0.15 0.314 0,14 0.309 0.14 0.291 0.13 0,432 .019 0.421 .019 0,421 .019 0,411 .019 0.389 .018 0.389 .018 0.477 .022 0.477 .022 1015040 1115040 1015050 1115050 1020020 1120020 1020025 1120025 1020030 1120030 1020040 1120040 1020050 1120050 1020060 1120060 1020080 1120080 1025025 1125025 1025030 1125030 1025040 1125040 1025050 1125050 1'025060 1125060 1025080 1125080 1025030 1025040 1025050 1025060 1025080 1040040 1040050 1040060 1040080 2- 1/2 x 2-1/2 x 65 x 3x 80 x 4x 4x 2x 50x 4 100 5-8 125.200 2 50 2-112 65 3 80 4 100 5 125 6 150 8 200 2-1/2 65 3 80 4 100 5 125 6 150 8 200 3 80 4 100 5 125 6 150 8 200 4 100 5 125 6 150 8 200 IiUiilt '.,'tWJ . I!l~ lib." DJ,...", tIP Sli.;~: JtzI 'JI Sliii~ ".:Ii.[mm 1.625 41.3 1.625 41.3 1,750 44.5 1.750 44.5 1,750 44.5 1.750 44,5 1,750 44.5 1.750 44.5 1.750 44.5 2.215 54.0 2.215 54.0 2.215 54.0 2.215 54.0 2,215 54,0 2,215 54.0 2.500 63.5 2,500 63.5 2,500 63.5 2.500 63.5 2.500 63.5 3.000 76.2 3.000 76.2 3.000 76,2 3.000 76,2 1,610 40.9 1.610 40.9 2.067 52.5 2,1167 52.5 2.067 52.5 2,067 52.5 2.067 52.5 2.061 52.5 2,067 52.5 2,469 62,7 2,469 62.7 2.469 62.7 2.469 62.7 2.469 62,7 2.469 62.7 3.068 71.9 3.068 71.9 3,068 77.9 3.068 77.9 .3.068 77.9 4.026 102.3 4.026 102.3 4.026 102.3 4.026 102.3 0.875 22.2 0.875 22.2 0.875 22.2 0,875 22.2 0.875 22.2 0.815 22.2 0.815 22.2 0,875 22.2 0.875 22.2 1.125 28.6 1.125 28.6 1.125 28.6 1.125 28.6 1.125 28.6 1.125 28.6 1.500 38,1 1.500 38,1 1.500 38.1 1,500 38.1 1,500 38.1 2,000 50.8 2.000 50.8 2.000 50.8 2.000 50.8 PAGE 2 OF 4 WIJtbt fie} ,--,jill' 0,477 ,022 0.477 .022 0.857 0.38 0.829 0,38 0,829 0.39 0.800 0.36 0,743 0.34 0.743 0.34 0.743 0.34 1.250 0.55 1.200 0,55 1.150 0.52 1.150 0.52 1.150 0,52 1.150 0.52 3.100 1.41 3.100 1,41 3.100 1.412 3.100 1.412 3.100 1.41 5.000 2.27 5,000 2.27 5.000 2.27 5.000 2.27 Merit Weld-Miser Tee-Let Welding Outlet Fittings , . PAGE 3 OF 4 Type B Male Thread Standard WeIght Type C Cut Groove Standard Weight 111( .j I~E-"I A A .f .. . " , ",/tvi " , ' ,.' .. ,', II!./mm .' ':f"': w~jjJiI " '7Jj'~; " ..i1l1l1 11.1(' .. ' tlIi/llfW' ~ftl~.,. , Cril.,. ,:~=;::" HBaur DuU.1 Insld. Oallld. A. ' flC/l. .' . ".. , ::, _i'"W.I. 'Sc~.fD ' : slii8 ltli>>1h ' Dlimelu Olamelar , !.trrJe ~ .WL, ' , S~.~' $itt b Sliil, .~;' f . , . . " ". ~ . . ~..":. .,: .. .- ,m.w.,~ ", '. ..... '.:. 1310012 2010012 2210012 1x 1-1/4 -1.1/2 3 1,049 1.315 0,133 1.500 251 32 - 40 80 26.6 33.4 3.4 30 1310015 2010015 2210015 1-1/2 - 2 3 1.049 1.315 0,133 1,500 40 - 50, 80 26.6 33,4 3.4 30 1210020 2010020 2210020 2 - 2.1/2 3 1.049 1.315 0,133 1.500 50 - 65 80 26,6 33.4 3,4 30 1310025 2010025 2210025 2-1/2 - 4 3 1.049 1.315 0,133 1.500 65 - 100 80 26.6 33.4 3.4 30 1310050 2010050 2210050 5-8 3 1.049 1~315 0,133 1,500 125.. 200 80 26.6 33.4 3.4 30 1312012 2012012 2212012 1-1/4 x 1-1/4 3 1.368 1.660 0,140 1.500 32 x 32 80 34,7 42.2 3.6 30 1312015 2012015 2212015 1-1/2 3 1.368 1.660 0,140 1,500 40 80 34.7 42.2 3.6 30 1212020 2012020 2212020 2.2-1/2 3 1.368 1.660 0.140 1,500 50.. 65 80 34.7 42.2 3.6 30 1312025 2012025 2212025 3-4 3 1,368 1.660 0.140 1.500 80 . 100 80 34.7 42,2 3.6 30 1312050 2012050 2212050 5-8 3 1,368 1.660 0.140 1,500 125 - 200 80 34,7 42.2 3.6 30 1315015 201-5015 2215015 1-1/2 1 1-1/2 3 1.610 1,900 0,145 1.500 401 40 80 40.9 48.3 3.7 30 1215020 2015020 2215020 2 3 1.610 1.900 0.145 1.500 50 80 40.9 48.3 3.7 30 1315025 2015025 2215025 2.1/2 3 1.610 1,900 0.145 1.500 65 80 40.9 48.3 3,7 30 1315030 2015030 2215030 3-4 3 1,610 1.900 0.145 1.500 80 - 100 80 40.9 48.3 3.1 30 1315050 2015050 2215050 5-8 3 1,610 1,900 0.145 1.500 125 - 200 80 40.9 48.3 3.1 30 1320020 2020020 - 21 2 3 2,067 2.375 0.154 1.500 50 x 50 80 52.5 60.3 3,9 30 1320025 2020025 - 2.1/2 3 2.067 2,375 0.154 1.500 65 80 52.5 60.3 3.9 3D 1320030 2020030 - 3 3 2.067 2,375 0.154 1,500 80 80 52,5 60.3 3.9 30 1320035 2020040 - 4 3 2,067 2,375 0.154 1,500 100 80 52.5 60.3 3.9 30 1320050 2020050 - 5 3 2.067 2,375 0,154 1.500 . 125 80 52.5 60.3 3.9 30 1320060 2020060 - 6 3 2.067 2.375 0.154 1.500 150 80 52.5 60.3 3.9 30 1320080 2020080 - 8 3 2.067 2.375 0.154 1.500 200 80 52.5 60.3 3.9 30 Note: Tee-leIs are manufactured 10 fit size-on-size, that is the contoured shape on a given Tee-Let is made to lit perfectly on the first listed header size. rf InslaDed on the second header size marked on the fitting, a slight gap of approximately 1132" will appear along the longitudinal centerline of the head- er. For example, a 1" x 2 - 2-1/2" Tee-Let, is a 1. outlet fitting manufactured to lit perfectly on the 2' header size listed, while leaving a 1132. gap along the Iongiludinal cenlerline of the 2-112" size. If a perfect lit is required for a 2-1/2. header pipe, then a 1. x 2-1/2 - 3" Tee-let would be ordered. Size con- solidations are employed to reduce inventory and provide for greater flexibility. Merit Weld-Miser Tee-Let Welding Outlet Fittings I;'AGE 4 OF 4 Type B Male Thread Standard Weight Type C Cut Groove Standard Weight I~E~I A .1 '1 "::ifr~. ' In~ '1inlll .' Cui, 11'011 WIIAIiI , $fOo., BraDV' 'IOliiJIlJ' IIjai!ilat OUlllt 111..l.d; .lii$ldt F waii ibl~~f.' 'S";WI,' ','~:' I,II.1D t:i1 ,:'.'~~t' .~~~ ,,:=~ D1a~~1 fi~'" ....-;.- " ~if ,~. " ' , '~'?fE , Sl~.' .S~.;',1~: ui./kp .,.', 1325025 2025025 2225025 2-112 x 2-112 3 2,469 2.635 2.875 0.203 0.120 1.500 2125025 65 x 65 80 62.7 &7.0 7&.2 5.0 3.0 30 1325030 2025030 2225030 3 3 2.4&9 2.&35 2,875 0.203 0,120 1.500 2125030 80 80 62.7 67.0 76.2 5.0 3.0 30 1325035 2025040 2225035 4 3 2,469 2.635 2.875 0.203 0.120 1.500 2125040 100 80 62.7 67,0 7&.2 5,0 3,0 30 1325050 2025050 2225050 5 3 2.469 2.&35 2.875 0.203 0.120 1.500 2125050 125 80 62.7 67,0 76.2 5.0 3.0 30 1325060 2025060 2225060' 6 3 2.469 2.635 2.875 0.203 0,120 1,500 2125060 175 80 &2.7 67.0 76.2 5.0 3.0 30 1325080 2025080 2225080 8 3 2.4&9 2,635 2,875 0.203 0.120 1.500 2125080 200 80 62.7 67.0 76.2 5.0 3.0 30 1330025 2030025 2230025 3x 3 3 3,068 3,260 3.500 0.216 0.120 1.500 80 x 80 80 78,0 83,0 88,0 5.0 3.0 30 1330030 2030030 2230030 3-112 3 3.068 3.260 3.500 0.216- 0.120 1.500 85 80 78.0 83.0 88.0 5.0 3,0 30 1330035 2030035 2230035 4 3 3.068 3.260 3.500 0.216 0,120 1.500 100 80 78.0 83.0 88.0 5.0 3.0 30 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 1.500 125 80 78.0 83.0 88.0 5.0 3.0 30 , 1330060 2030060 2230060 6 3 3.068 3.2&0 3,500 0.216 0.120 1,500 150 80 78.0 83.0 88.0 5.0 3.0 30 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0,216 0.120 1.500 200 80 78.0 83.0 88.0 5.0 3,0 30 1340040 2040040 2240040 4x 4 4 4,026 4.260 4,500 0.237 0.120 1.500 100 x 100 100 102.0 108.0 114.0 U 3.0 30 1340050 2040050 2240050 5 4 4,026 4.2&0 4.500 0.237 0,120 1.500 125 100 102.0 108.0 114.0 &,0 3.0 30 1340060 2040060 2240060 6 4 4.026 4.260 4,500 0,237 0,120 1,500 150 100 102.0 108.0 114.0 6.0 3.0 30 1340080 2040080 2240080 8 4 4.026 4,260 4.500 0.237 0.120 1.50 200 100 102.0 108.0 114.0 6.0 3.0 30 2060060 2260060 6x & 4 6.065 &.357 6.625 0.280 0.134 1.500 150 x 150 100 155.0 161.5 168.3 7.1 3.0 30 2060080 2260080 8 4 6,065 6.357 6.625 0.280 0.134 1,50 200 100 155.0 161,5 . 168.3 7.1 3.0 30 2080080 2280080 8x 8 4 7.981 8.329 8.625 0.322 0.148 1.50 200 x 200 100 203.0 212.0 213.0 8.0 3.0 30 Note: Tee-lets are manufactured to fit size-on-size, that Is the contoured shape on a given Tee-Let is made to fit perfecUy on the first listed header size. If Instal/edon the second header size marked on the fitting, a slight gap of approximately 1/32" will appear along the longitudinal centerline of the head- er. For example, a 1" x 2 _ 2-1/2" Tee-Let, is a 1" outlet fitting manufactured 10 fit perfectly on the 2" header size listed. while leaving a 1132" gap along the longitudinal centerOne of the 2-1/2" size. If a perfect fit Is required for a 2-1/2" header pipe, then a 1" x 2.112 - 3" Tee-let would be ordered. Size con- solidations are employed to reduce inventory and provide for greater flexibility. I~E~I A CLEVIS t'Y:>>~ 4N\I1L: ~ .~.., rUUM,nIOAAL. IU Fig, 260 Adjustable Clevis Hanger Size Range: 112'through 30' Material: Carbon steel Finish: 0 PlaIn or 0 Galvanized, also available 0 plastic or 0 epoxy coaled Service: Recommended for the suspension of stationary pipe Jines. MaxImum Temperature: Plain 650. F, Galvanized and Epoxy 450. F Approvals: Complies with Federal Specification A-A-1192A(Type 1), WW-H-171-E (Type 1) and MSS-SP-69 (Type 1). UL, ULC Listed and FM Approved (Sizes 3/.'through 8'). Installation: Hanger load nut above clevis must be tightened securely to assure proper hanger performance. When an oversized clevis is used, a pipe spacer should be placed over the clevis bolt as a spacer to assure that the lower U-strap will not move in on the bolt. For ductile iron pipe sizes, see Figure 590, Adjustment: VertIcal adjustment without removing pipe may be made from 3fs'through 5118', varying with the size of clevis. Tighten upper nut after adjustment. Features: · Design has yoke on outside of lower U-strap so yoke cannot slide toward center of boll, thus bending of bolt is minimized. · Sizes 5' and up have rod and, two nuts instead of bolt and nut; thread length on clevis rod is such that the thread Jocks the nuts in place, and threads are not in shear plane. Ordering: Specify pipe size, figure number, name and finish. Note: Punched forming holes may be present on certain sizes of this clevis hanger. These holes are solely for the purpose of manufacturing, and do not effect the structural integrity or load carrying capacities of these hangers. 112' through 3f4' Pipe l' through 30' Pipe Fig. 260: Loads (Ibs) · Weights (Ibs) · DimensIons (in) Pipe Max Span W . hi Rod B C Rod Take Adjust. G Size Load Ft, elg Size A Out E F ~ I I '~,34 2~6 1m! --1 610 ~- 1------ 21~6 I--------j 0/'1 i I 0.34 ,IL' _2 I 1~6-1 L-1'1'~ -=",~_'---II r rOO"4305 I ~I m i ~ '14 ,. % 2% I -314 r-,%! I -jih--j 730 /--9;- I 0.45 . 21~8 T-31~6 -I,'--2~----l, ---I,i--/ ----I t---._-L 2 i I 10" I 0.50 3~6 4t-i I 2~ Hi Ll~_j 1_~_!!.:..J__~,65 -1/ 4Yl~_+ 5~ J_~~6 ---.L~--I IL-3-~,r;-~i! 1,350 It.. 113~-"-I~---0,,',805 - t-i ~L 6~_L__~~-.1_1!..._ % n 5~6 7~. I 4~6 ! 11~. r 4 i I 14" ! 1.51! ' 5~& L71~6 I 4t-i I 11~. " rT-j,I,430 r16-;-L'.70 I * r~-;'I 8'~6 t----5th-----~--. % L 6 1940. 17 I 310 I 61~. I 10\4! 5~ ) 11~6 I --8-1- 2:oo0-i-1i-T 4:75.j i~-T12i~;T-- 7~6 -- ----2'1 ~ -~~-~H~~'I-~~;'- -1~.~~ I r 1i:6 -tl~~~~.t-- :~--~'-2~~~~~ __~~L_2~~_L_'2,50 ! ! 12~& I 19~6 I 101~6 21~& I ~ --~H'-~::~~'+'- ::__.L~:::}_/ ~~~~F24~~t~13~~6 - ~~~6 -r--- _.3.l!......L 4,800 L_~-1 40_33 J I 1m6 L2m6 L~~~___ 3~ I 24 i 4,800 I 32 4~ 1\4 191~6 I 311~.! 17~6 ! WI 30-- j- 6,000-- too -33--- --70.181 24~-;--r -3~6j-- 21 ~6---m-5i---1 .Span' represents the maximum recommended dis1ance between hangers on a continuous and straight run of horizontal standard weigh! steel pipe filled with water. In all cases, verify that chosen location of hangers does not subject hangers to a load greater than the maximum recommended load shown above. "Indicates that span represents the maximum span for water filled pipe as given In Table 1 of page PH-207. Pipe Hanger Submittal Sheet Project: I Architect I Engineer: Date: ____________..1 Phone: Contractor: Address: Notes 1: Notes 2: Approval Stamp: COPPER TUBING HANGERS (~)~..~ .__lI'_ Adjustable Tubing Ring Adjustable Tubing Ring (Plastic Coated) Fig. CT,"99 Fig, CT-99C FIg. CT-99: Adjustable Tubing Ring SIze Range: 1/2' through 4' Material: Carbon steel ring and malleable iron adjusting nut. Finish: 0 Copper plated Service: Recommended for suspension of non-Insulated stationary copper tube. Approvals: Complies with Federal Specification A-A-1192A (Type 9) WW-H-171-E, (Type 9) and MSS-SP-69 (Type 9). Installation: Full load carrying capacity is reached when the rod is screwed to the bottom of the opening in the nut. Features: . large sight hole provides means of assuring thread engagement. . Sized for copper tubing. . Greater vertical adjustability. . Nut may be attached to rod before pipe is picked up in band and snapped into position. . Competitively priced. Ordering: Specify nominal tube size, figure number, name. Fig, CT-99C: Coated Adjustable TUbing Ring Size Range: l/2'through 4' Material: Carbon steel ring and mal/eable iron adjusting nut. Finish: 0 Copper plated with the band plastic coated. Features: Eliminates possibility of galvanic action between hanger and copper tubing. Ordering: Specify nominal tube size, figure number, name. Fig. CT-99, Fig. CT.99C: Loads (Ibs) . Weight (Ibs) · Dimensions (in) Tube Max Rod ,. 8 Adjustment Weight Size Load Size A I j E 1~-'-'-3'~42 --i" I.----~.~~ __.J I ~~ 13/4 ! IC:~~=-l 400 i=:it:=:j 'I. f:~~ ~~:t __W:_l ___ __ ___ ______1 . --- -- .---- n_ - , f-----.....--+---i 19/16 1'12: I 0,17: : 31/8 ! 23/8 , I [_-:~-- 2 1--------..1- :~=O'17 ~:.=.' L t- 35/;;r 29/1~-r--1ih---~~l L.___21f2 __-1 l..__~:.~___J--'-'[~?8.1 3 _=r--- 1~~ _~ L_,_~--J 650 L__~~__-' 1/2 ! 4'/4 I 33/8! j13/16 J ! 4 i i 0.41' ' 51f16 ! 43;1~ i .-n----zVa----.j Pipe Hanger Submittal Sheet Architect I Engineer: Approval Stamp: I Phone: Project: Date: Contractor: Address: Notes 1: Notes 2: ~ (Y)~l~ HANGER RODS Fig. 146 Continuous Threaded Rod Size Range: 114' through H~' Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Garbon steel; rod threaded complete length, Finish: 0 Plain or 0 Galvanized. Maximum Temperature: 650. F. Ordering: Specify rod diameter and length, figure number, name and finish. / t ,I h., ' I,'j': I~: 1,' J\ I : II 11l ! {: J::"',;' 'J" t'; :J'; ! 11~.' /' ,lenglh '/ A Fig. 146: Loads (Ibs) · WeIghts (Ibs) DImensIons (In) Rod Threads Max Load WeIght SIze A per Inch 650. F per Ft. 1/4 , 20 i 240 i 0.12 ' -----'3h-.-'.--->---16--,-------ffir----1.------o.aT------ f-----,/2--t------r3---+ 1 ,350 1---'--0.53 -------- ~'--.-.-.5;a---.--~L' ----11.---+--.-2:-160---r-----0. 84'-.------ ---- 3/4-----,-'--11)-----'1-3;230 -'-,---'-1:'2--0---'--' ---=:1fa=r--- 9 -=~I- 4.480~-----t-=~=_ 1.-~~~~-.==-_ ---'-.1 ~4 ---I-----,+----+---;;~~--..--+-----.~ :~~--. --.--., -,.... -------+--.,---.-,-,-,1----._.______..___4__.___.,_______...._.,_ 1lJ2 i 6 i 13.800 I 5.10 Note: Other rod sizes available upon request. Class 2 1it is available upon request. Pipe Hanger Submittal Sheet Architect I Engineer: Phone: Project: Date: Contractor: Address: Notes 1: Notes 2: Approval Stamp: COPPER TUBING HANGERS (,rj~NYA~~ Fig. CT-65 , Light Weight Adjustable Clevis Size Range: w through 4' Material: 0 Carbon steel FInish: Copper plated. also available in yellow dichromate and plastic coated. Service: Recommended for suspension of non-Insulated, slallonary copper tube. Approvals: Complies with Federal SpecificationWW-H-171-E (Type 12), Installation: (1) Adjustment may be made either before or after tubing is in place without temporary support of pipe. (2) Hanger rod and nuts may be locked into position after adjustment by use of the upper nut. Features: Provides for adjustment up to 1%". Ordering: Specify nominal tube size, figure number, name and finish Project: Date: Contractor: Address: Notes 1: Notes 2: Fig. CT-65: Loads (Ibs) -Weight (Ibs) - Dimensions (In) ~:: l~~~ WeIght ROdASIZ~ B ~JRg~~~~e-e~~nt 1/2 150 0.09/ L 1'/2 I 127/32 J~~1___,~~~_____L____5~~~____ 3/4 010 I I 1"/16 I 23/32 ) 19/16 I 11/4 I 7/16 ~- ---1 t-..----r--..--~'_,_'---...-...-,.-.--..r.'--.--'-..-.--.,..---..-' ",.__~___. I,__.~~_~..._I 1.,.__~~a__I--~~~-I-...1-~.--j-..-..~,~~~~-.-......,-i...__"..,.._.".1~2..... _.__. .~~4._.1 250 L.~:_1~._.J i__~~~:2.,J__~~.3~~.J___~~~4___L.._.~.~1~~_6.._ L. 5fa H~I I-:+~i '!. H;~+ ,~:~;r~~-{~;- ---;~;; ["2 '/2 ---....-.m'I'''(J.4S- i /-'3-27/;;--':-'59/;;-'r-23;;+--31/; -- " ,- , 15/16 _......____'.., 350 ,.__..___,....1 1._,...___.____.../-.__._.......;__...-.,......- ..-.1.. ...m'...._.._..."...'. ,. . m..'...._..' i 3 I 0,55 ! L.~~~..t..6~~__.r..~_..I_ 371& i Wa "-'--4"'-'--400'-1' 0.60) I 431/32 I 631/32 I 31J4 1 43/8 ~__~/~ - Pipe Hanger Submittal Sheet Architect / Engineer: I Phone: I._____,_..__.__._,_______._ Approval Stamp: ~~'a_._.__.______------- PIPE RINGS 1:Yj~ 4NV1L: ~\ "I' ,."..."..... '"' Fig. 108 Split Pipe Ring Size RanDe: 3/8' through 8' Malerial: Malleable Iron Finish: 0 Plain Service: Recommended for suspension of non-insulated stationary pipe lines or conduit. May be used with rod socket Fig, 110R or turnbuckle adjuster Fig. 114. Maximum Temperature: 450' F Approvals: Complies with Federal Specification A-A-1192A (Type 11) WW-H-ll1-E (TYpe 11) and MSS-SP-69 (Type 11). Features: · Permits installation before or after pipe is in place, · Provides economlcallnsta/Jatfoil. · Permits use of universally adaptable parts. Orderi~g: Specify pipe size, figure number, name. Figure 108: Loads (Ibs) · Weight (Ibs) · DimensIons (In) Pipe Size Max Load Bolt Size 3/8 1f2 I --t-.------ 3/4 I i-_~~__ 11/8 --i 1/4 x 1 ~~~~~-J L~~_L 11/4___/ 1% 1 300 1 0.18 I 19116 I ----.--.--.-.-..~ ~._----~___._l.__~_____._._._.__.__ ___~_11z __..../ ~~-J-~~J . I 03 il' F=~2.!~=~j---------------1:~4:--:~L ~~~=.I1f4 x 11/4 3 ! 450 ! 0.63 I 23/4 ! ,------------i ~----+--._j 1'----'~~~=---..f..,-,-..-.-.--------1--~~:; ---+--~r~--f-------- --.....,------..1 520 ,--,---1-------4 3fax 2 I-.-----~____._I_"".., ... -.---------.I---~:-~-..L ..~_1~~_ ,..1.. _, ..___._._ I 6 I 1,300 ,2.60 I 51/16 i r--...------"j--- ,- ----------- 'J----.-------t-..----j 1/2 X 2 I 8 I 1,800 5,20! 6318 I 200 i #10x1fa !-.------- 15/16 Project: Dale: Conlraclor: Address: Notes 1: ------.----- Notes 2: Pipe Hanger Submittal Sheet Architect / Engineer: f Phone: Approval Stamp: ~ ,:. _J_--~;-- FIB I -j 13/32 ~-! ROD ATTACHMENTS Fig. 114 Size Range: 1f4' through 3f4' Malerlal: Malleable iron Finish: 0 Plain Installation: Normally used with split pipe ring, Fig. 108. see page PH-22 Ap pravals: Complies with Federal Specification A-A-1192A (Type 15) WW-H-I71-E (Type 15) and MSS-SP-69 (Type 15), Maximum Tempera,ure: 450. F Features: . An economical and simple means of Obtaining vertical adjustment and flexibility at the pipe connection. . Permits adjustment after pipe is in place, Ordering: Specify rod size. figure number and name. Ag.114: Loads {Ibs} -WeIghts (Ibs) - DImensions (In) Rod Size A If. 3/B 1/2 5/B 3/4 47/8 415/16 B Max Load Weight 0.09 0.28 0.31 0.72 0.70 25/16 230 2lf2 313/16 730 F I ~ 860 (~jJ.\Mf.l~ Turnbuckle Adjuster 1/2 9/16 ---------------- - Project: Date: Contractor: Address: Notes 1: Notes 2: p'ipe Hanger Submittal Sheet Architect / Engineer: Phone: Approval Stamp: _ ~"'",.c'_..~",.,._.____.__".."~._"^'.",._""_.6___._"""..____'""~,~._.,.,.,.;'-. ~ BEAM CLAMPS ~ Fig. 94 Size Range: Sfa' and 3f4' Material: Mal/eable/Ductile iron body, hardened stee/cup point set screw and locknut. finish: 0 Plain or 0 Galvanized Service: Recommended for use under roof installations with bar joist type construction, or for attachment to the top flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joists or flange does not exceed 15/16'. Approvals: Complies with Federal Specification A-A-1192A (Type 19) WW-H-111-E (Type 19) and MSS-SP-69 (Type 19). UL Listed and FM Approved. How to size: Size of clamp ;s determined by size of rod to be used. Installation: Follow maximum recommended set screw torque values per MSS-SP-69. (See tables on see page PH-212) Features: · Provides clamping to bar joists which are directly under roof installations. · Provides for vertical hanger rod installed offset from the edge of the beam flange. · Malleable iron body assures full thread engagement of rod. Ordering: Specify rod size, figure number, name of clamp and finish. .. ,,- i: ! i I~ jF, ff[~l Fig, 94: Load (Ibs) . Weight (Ibs) . Dimensions (In) Rod SIze A Max L~~dS/a Weight 8 ----.----~!.-_.._____._..L____~_, 2 o_~_ 3/4 I 1,600 ,- Maximum temperature of 450. F I 0.66 .....-...---.-1-- .--.--....-....-.----__ i 0.83 . -]-~~__.___L ___2_~~____J 1% I 2% I fO _:}\\ ANVil $ ,1( J~ I'" ... ~)'\ ~ "'U..Ula."L.IHt Wide Throat Top Beam C-Clamp ", " '<....". " . '. "'.. '''. / D F ._--------_..__._--~-_.._-----------------_._--_..~------ 3f4 i__~X~_ I 1% ! ...._. ..L___._____._~.________ i 13/16 -------.-------------------------------------------- Pipe Hanger Submittal Sheet --------rArchitect / Engineer: -------- -----------~~~~_:~------_._--------_. Projecl: Date: Contractor: Address: Notes 1: Notes 2: -.--------------------------.--.---.---------------------- -------------------------------------..- ------------- Approval Stamp: Dyna-Flow@ High Strength Steel Pipe The original hlgh-strength Ilghtwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-lO pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system, With an inside diarneter of up to 11 % larger than Schedule-40 and up to 7% larger than Schedule-lO, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Dyna-FloW products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating, This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and u.v. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation, The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed, , NPS Nominal 1.0. Wt. WI. (H20 Filled) Pes! Wt,lllft (21') Wt,lllft (24') Wt,Illft (25') In;mm In;mm LbsIFt; Kg/m LbslFt; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg l' 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1V4' 1,536 1,059 1,87 61 1,356 1,550 1,615 32 39.0 1,6 2.78 61 615 703 733 1W 1,728 1,667 2.71 61 2,135 2,440 2.542 40 43.9 2.5 4.03 61 968 1107 1153 2' 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2W 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7,59 30 733 837 872 3' 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4' 4.310 4.473 10.86 19 1.784 2,039 2,124 90 109,5 6.7 16,16 19 809 925 963 Specifications & Approvals Additional Benefits . Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. . Provides stability needed to comply with standard hanger spacing (15 ft a.c.) per NFPA. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14, All sizes of Dyna Flow/Super FIo are UL Listed, FM Approved and ULC Listed. . Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. . Fast cutting and welding, as well as easy roll grooving and end preparation. . Available in Factory roll grooved form for quicker shop turnaround. . Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. @<S>~ Listed Approved Listed Dyna-Flow/Super Flo is ULJULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information, Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses, 1:L/CD / Flow Control (T) allied TUBE & CONDUIT 16100 S, Lathrop. Harvey. IL 60426 11350 Norcom Rd, ' Philadelphia. PA 19154 2525 N, 27 th Ave. . Phoenix, AI. 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 52 - 3