Loading...
HomeMy WebLinkAbout07-7221 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 7221 Permit Number" 7221 Permit'Type: COMMERCIAL Class of Work: ADD/AL T COMMERCIAL Proposed Use: COMMERCIAL Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: 52,106.00 11/29/2007 Address: 38445 5TH AVE ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 11-26-21-0010-15300-0080 Name: AS D, HAZEM G. Address: 38445 5TH AVE \3 ./ ZEPHYRHILLS, FL. 33542 / Phone: NEW STOREFRONT FASCADE 38445,38449 5TH AVE ~j\J ,()~ ~/3b RE- LINTEL SHEATHING FRAME INSULATION WALL BUILDING FINAL FOOTER REINSPEcnON FEES: Reinspection fees will comply with Florida Statute 553.80 (2)( c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." TRACTOR SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER " City of Zephyrbills BUILDING PLAN REVIEW COMMENTS ContractorlHomeowner: ~ldC.\.n~ C:.rn~u~~ Date Received: t\ -\ q -0., Site: o<i$44S 5+h ~e.. ~ ~~.\- ~r~r>llo Permit Type: Approved wino comments: 0 Approved withe below comments: f Denied withe below comments: D RruD1 tV (7 le, 0 JU. 010bL\ ~o'\,dc.. 6~~ (YYU....b-t- 'be.. ~+. (JSe &~ q. '\0 Yr\ ph t U 1(\("\ --z.orw h IVY) ,+ kept with the permit and/or plans. Date C:Jl &- Contractor and/or Homeowner (Required when comments are present) ~tJ /11) 813-780-0020 City of Zephyrhills Permit Application Building Department Fax-813-780-0021 Date Received It,. \ l1 -0'7 Owner'sName Haum G. A~d Owner's Addr,ess 13'?l{'iS ~ Ave(\vt!- Fee Simple Titleholder Namel Owner Phone Number Owner Phone Number I Owner Phone Number I JOB ADDRESS Fee Simple Titleholder Address I 13~l{45 I S.!J Aveflte. LOT # PROPOSED USE TYPE OF CONSTRUCTION NEW CONSTR INSTALL SFR BLOCK PARCELlD#1 \ \ -'?lD .1.\... (:j1)\O - 'S3c5/.) -- Ol)~ (OBTAINED FROM PROPERTY TAX NOTICE) SIGN D MOVE D I ~ ADD/ALT D ~ REPAIR D COMM D D FRAME D f\ew stor'- front ~cG\de BUILDING SIZE I I SQ FOOTAGE I I HEIGHT I 1111 , till 11111 11111 11111 III 11111 11111 11111 11111 11111 II , 11111 III III II III II III II I I III ' 111111111111 ' I11111 ' '11111 ' , 111111 1111 ' , 1111 , 1I11111 ' III tllIlI ~ BUILDING 1$ 5;),/()(P. ~ I VALUATIONOFTO~ONSTRUCTION o ELECTRICAL 1$ N/A I AMP ;:;~Co:J..~ 6"'~ PROGRESS ENERGY D PLUMBING 1$ 11't(Ji'''-C '(\~~~ ~ NDC- ' Nt A c ~ 0.-vY' 6QAN"I it" ~ ;.)\ Q; ~ D MECHANICAL 1$ N/A I ~VALUATION OF MECHANICAL INSTALLATION PU\}<s &-+0 ~<:Jl..Q.& . pc"-r ~ c-/Iq /67 D GAS D ROOFING D SPECIALTY D OTHER qm - 11119 {()7 ~ FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA DYES DNO tJcit- ~ SUBDIVISION DESCRIPTION OF WORK B D D I Build DEMOLISH WORK PROPOSED OTHER STEEL I D OTHER I D W.R.E.C, BUILDER I AU -I J / ( ~J.I/ /J I SIGNATURE ~ ..M/. ~ . Address I/Lf"{1 E.G~ry Rd. LAkdcUld,FI 3380l , ELECTRICIAN I I SIGNATURE . Address I PLUMBER I SIGNATURE I COMPANY REGISTERED Address MECHANICAL I SIGNATURE Address I I I I I I I License # I I ~~':.':."TURE I~ ~ ~~~':.': ~FE~; 1\~~/~t II'II~'~~~~~::~ t:~;~~~ 11~~~lllfill ~~~~II }IIIIIIIIIIIIIIIIIII ~:~;~~~ ~III,I"IIIIIIIIII'IIIIIIIIIIIIIIIIII,I' RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wI Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects Attach (3) sets of Building Plans; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wI Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance Attach (2) sets of Engineered Plans. ....PROPERTY SURVEY required for all NEW construction. License # IcaCO(,OlbS COMPANY REGISTERED Y/N FEE CURRENT Y/N License # COMPANY REGISTERED Y/N FEE CURRENT Y/N License # COMPANY REGISTERED YI N FEE CURRENT Y/N COMMERCIAL SIGN PERMIT Di~~~ii~~~.: I . I I . . I I I I I I I . . I I . . . . . . I I I . . I I I . I I I I I I I I I I I I I . I I I I I . I I I . I I I I I I . . I I I I . I I I I I I I I . . I I I I I I I . I I I I I I I . . I . I I I I I . . I I I I I I I I I I I I I I I I I . . I I I I I . . I . . I Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AlC upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (PloUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local re~ulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor ,violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to .a~verseIY affect adjacent properti~s, the. ow~er may be cited for violating the conditions of the building permit Issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. 1 understand ~hat a s,eparate perm~t. may ?e requir~d for elect~ica.1 work, plumbing, signs, wells, pools, air conditioning, gas, or other Installations not speCifically 1n?luded.ln the application. A permit issued shall be construed to be a license to proceed with the work a~d not as authont.y ~o vlol~t~, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the B~J1.dlng OffiCial from the~eaft~r requiring a correction of errors in plans, construction or violations of any codes. Eve~ ~ermlt Issued. shall become, invalid unless the work authorized by such permit is commenced within six months of permit Issu~nce, or If work authonzed . by the permit is suspended or abandoned for a period of six (6) months after the time th~ work IS commenced,. An extension may be requested, in writing, from the Building Official for a period not t~ exceed n1n~ty \90) da~s and Will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the\Job IS conSidered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORN BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.0 ' cONTRAcToR.6triddNlcl ~ruc+ion I Inc. . Subscribed and swo~ affi~~e me this Nw. 13 ;)oOi by . g ..( Who Is/~re personally known to me or has ave produced as identification. OWNER Subscribe or affirmed) before e this N(')0. JIb 2007 by f-ll,nM G Aben WWo is/MS personally known to me or has/have produced as identification. 'S.cx 1'..v-"~ ~O.l! Y <--- Notary Public Name of Notary typed, printed or stamped FlondaNolaryS' Commission No. Permit No: STATE OF Florida, COUNTY OF Pasco NOTICE OF COMMENCEMENT Tax Folio No. THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property: 38443 & 38445 51h Avenue, Zephyrhills Florida Parcel ID No. 11-26-21-0010-15300-0090 Legal Description: ZH PB 1 PG 54 LOTS 9 -10 BLK 153 OR 7154 PG 163 111111111111 1111I111/11111/ 111111111111111 1111I ""'11111'11 200719!5239 2. General description of improvement: Storefront Renovation 3. Owner information a. Name and address: Hazem G. Abed, 38443 51h Avenue, Zephyrhills, Florida c. Interest in property: Owner d. Name and address of fee simple titleholder (if other than owner): nla Rcpt: 1144992 DS: 0.00 11/29/07 Rec: 10.00 IT: 0.00 Dpty Clerk R 4. Contractor: a. Name and address: b. Phone number: c. Fax number: Strickland Construction Inc. 1441 E. Gary Rd. Lakeland, FI 33801 863-683-8048 863-683-8349 JED PITTnAN, PASCO COUNTY CLERK 11/29/07 11: 04am 1 A/ 1.. OR BK 7700 PG -36a 6. Lender a. Name and address: nla b. Phone number: c. Fax number: , J e/,; STATE OF FLORIDA .>.......' ( COUNTvOFPASCO '--~~~.. f,'~ '<J~\ THISISToceRTIFVTHATnfrFBREOOINGI!L~:' ", c. 1RUE AND CORRECT COpy OF THE onciJ~"T ONRLE" .-, ()R OF PUBLIC RECORD IN THIS pt=FICt WITNESS MY ~ : . HAND ~p OFFICIAL SEAL nu's~. ,'DAY QF~,; ---:", ~...h.J 2 tJ4' '. ' . ~') ~;O P/TTM~CUITD~tdL~~~' ::~; '. . 5. Surety a. Name and address: b. Amount of bond $ c. Phone number: d. Fax number: nla 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a) 7, Florida Statutes: a. Name and address: nla b. Phone number: c. Fax number: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes: a. Name and address: nla b. Phone number: c. Fax number: 9. Expiration date of notice of Signature of Own.!!: ~ ~/" Owner's Name -:::' ,z e is 1 year from the date of recording unless a different date is specified) Owner's Address 38443 5th Avenue, Zephvrhills. FL 33542 Sworn to and subscribed before me by /1(1 7 r tv] (.~ f:} h f> rf who is personally known to me or produced as identification, and who did take an oath, this ~ day of f...JtlVc hl At' (' ,20 D 7. :~::::::~~:::ta'Y\ R~;Zlyl1 }~~:: SEAL: ..~\lf.~r~ BEVERLY A JONES f*=:& :*~ Commission DO 621878 ;!!J.' .". . ;l,t...~$ Exoires December 22,2010 RIlII""- IondId TIIIu ~ ~ '-- 800-386-7019 Commission No. IExpiration ~'l RIf~., ,:<l...,., , I~". -. ".,~ ,,'~ ~~ ~,;~~ ~ ~ :;,,:.,... ..... .......- ..- " ) ... (, . ,," // 1'[ R\ W, CLIFF McDUFFIE Mayor CITY COUNCIL KENNETH V. COMPTON Council President CELIA M, GRAHAM Vice President CLYDE C, BRACKNELL DANIEL W. BURGESS. JR. LUIS M. LOPEZ STEVEN F. SPINA City Manager LINDA D. BOAN City Clerk JOSEPH A, POBLlCK City Attorney City of Zephyrhills ~ tJ./ Ptere 1Q~ 5335 Eighth Street . Zephyrhills, Florida 33542-431 2 [81 3) 780-0000 . FAX [81 3) 780-0005 NOTICE TO PROCEED TO: STRICKLAND CONSTRUCTION, INC. 1441 E. Gary Road Lakeland, Florida 33801 FROM: CITY OF ZEPHYRHILLS DATE: November 15, 2007 PROJECT: C.D.B.G. #05DB-2Q-08-61-02-C06 - Storefront Renovations Strickland Construction, Inc., herein called the Contractor, is authorized to begin work on Monday, November 26,2007 at Hazem G. Abed's Building, located at 38443 and 38445 Fifth Avenue. All work will be done as specified in Contract C.D.B.G. #05DB-2Q-08-61-02-C06. Work will proceed on this job within 10 days from the date of this notification as provided in Section 0010 of said Contract, unless otherwise specified. Work on this job is scheduled for completion no later than on February 26,2007. Prior to beginning construction, all permits and licenses required by Local, State, and Federal law shall be obtained by the Contractor, unless otherwise specified. The method of assessing liquidated damages for noncompiiance with the project of said Contract is contained in Section 0010 of said Contract. -#1#J7 f odd H. Vande Berg Director of Development /1-/5--C) '7 Date ' II/fir:; 7 . / / Date / Pasco County Parcel: 11-26-21-0010-15300-0080001 Page 1 of 1 Search Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Friday, November 16, 2007 ParcellD 11-26-21-0010-15300-0080 (Card: 001 of 001) Classification 17 - 1 Story Office Mailing Address Assessment (totals) HUDGINS DREW BEN Ag Land $0 38453 5TH AVE Land $18,935 ZEPHYRHILLS, FL 335424328 Building $236,766 Physical Address - See All 2 addresses (First Shown) Extra Features $0 38445 5TH AVE ZEPHYRHILLS, FL 33542-4329 Total Assessment $255,701 Legal Description (First 4 Lines) Save Our Homes $0 ZH PB 1 PG 54 LOT 8 BLK 153 Taxable Value $255,701 OR 1883 PG 1932 Land Detail (Card: 001 of 001) Line I Use IDescrlptl.nl~nlts I Type II Price IICond~i.nl~ 1 I 1700 111STORY OFFI 3,500.00 I SF II $5.41 II 1.00 I $18 I Additional Land Information I Acres II 0.08 II Tax Area II 30ZH II FEMA Code [~]Commerical Codell M5AV2CB I Building Information - Use 17 - Offices (One Story) (Card: 001 of 001) Year Built 1916 Stories 2.0 Exterior Wan 1 Concrete Block Stucco Exterior Wan 2 None Roof Structure Flat Roof Cover BUilt-Up Tar and Gravel Interior Wan 1 Drywall Interior Wan 2 None Flooring 1 Carpet Flooring 2 None Fuel Electric Heat Forced Air - Ducted A/C Central Baths 2.0 I Line I Description Sq. Feet Repl. Cost New 1 AOF 1,536 $164,659 2 I CAN I 144 $4,610 3 I UST I 240 $10,291 4 I FUS II 1,776 II $190,387 I I Extra Features (Card: 001 of 001) I Line II Description II Year II Units II Value I I No Extra Features I Sales History Previous Owner II WALLER CHARLES D & Year I Month II Book/Page II Type I Amount 1990 I 02 II 1883 / 1932 II WD I $40,000 1983 09 If 1284 / 1494 I I $58,000 I I 1982 I 09 II 1209 / 1776 I I $31,700 I Search Aqain Show Map Generalized Buildinq Schematic Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections http://appraiser.pascogov.com/searchlparce1.aspx?sec=ll&twn=26&mg=21 &sbb=OO 10&... 11/1912007 Pasco County Property Appraiser - Physical Address List for: 11-26-21-0010-15300-0080 Page 1 of 1 Welcome : Records Search : Parcel Details : Physical Addresses Physical Address List for Parcel: 11-26-21-0010-15300-0080 , Displaying 2 record(s) View in groups of: 10 25 50 100 500 Street Number 38445 38449 Street Name + 5TH AVE 5TH AVE Unit Pasco County Property Appraiser Page Layout Modified: 10/9/20079:52:48 AM The Local Time Is: 11/19/20072:22:21 PM http://appraiser.pascogov.comlsearchlphysadd.aspx?parcel=212611 001 0153000080 11/19/2007 Pasco County Parcel: 11-26-21-0010-15300-0090001 Page 1 of 1 Search Again Show Map Generalized Buildina Schematic Estimate Taxes Frequently Asked Questions Other Parcel Cards: 1 I 2. Other Agency Data: Tax Collector School Board Suoervisor of Elections Data Current as Of: Weekly Archive - Friday, November 16, 2007 ParcellD 11-26-21-0010-15300-0090 (Card: 001 of 002) Classification 11 - Retail Stores, One Story, All Types Mailing Address Assessment (totals) ABED HAZEM G Ag Land $0 38445 5TH AVE Land $37,870 ZEPHYRHILLS, FL 335424328 Building $300,223 Physical Address Extra Features $0 38443 5TH AVE ZEPHYRHILLS, FL 33542-4328 Total Assessment $338,093 Le9al DescriDtion (First 4 Lines) Save Our Homes $0 ZH PB 1 PG 54 LOTS 9 - 10 Taxable Value $338,093 BLK 153 OR 7154 PG 163 Land Detail (Card: 001 of 002) I in.. Use Description Zoning Units Type Price Condition Value 1 1100 STORE 1FLR 00C2 7,000.00 SF $5.41 1.00 $37,870 Additional Land Information Acres II 0.16 II Tax Area II 30ZH II FEMA Code II X IICommerical Codell M5AV2AB _fJuilding Information - Use 11 - Retail Stores (One Story) (Card: 001 of 002) Year Built 1922 Stories 2.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 None Roof Structure Flat Roof Cover Built-Up Tar and Gravel Interior Wall 1 Plywood Panel Interior Wall 2 Drywall Flooring 1 Cork or Vinyl Tile Flooring 2 Pine or Soft Wood Fuel Electric Heat Forced Air - Ducted A/C Central Baths 4.0 Line Description Sq. Feet Repl. Cost New 1 .s..D8 4,000 $513,400 2 CAN 430 $16,557 3 EST 920 $59,041 4 UUS 4,000 $256,700 Extra Features (Card: 001 of 002) Line II Description II Year II Units II Value No Extra Features Sales History Previous Owner UNVILLE DANNY R Year Month Book/Page Type Amount 2006 08 7154 / 0163 WD $400,000 2002 07 5017/1841 ~ $0 1992 09 3064 / 0147 cr $0 Search Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Parcel Cards: 1 I 2. Other Agency Data: Tax Collector School Board Suoervisor of Elections http://appraiser.pascogov.comlsearchlparce1.aspx?sec=11&twn=26&mg=21&sbb=0010&. .. 11/20/2007 JAN~25-2008 03:50P FROM:5TATEWIDE ROOFING 8636885889 - TO: 18137800021 P.2 - -",-",- -.-",- ...:" ~.-"., CC C049375 P.O. Box 2781 . Lakeland. FL 33806' (863) 686-1451 . Fax: (863) 688-5889 January 25, 2008 I, Curtiss Dell James, do hereby-authorized Julia Faulk to represent Statewide Roofing & Sheetmetal Inc" in registering, pulling permits. signing off on permits and notice of commencement. Respectfully, Curtiss Dell James 1- 2--~- tP ~ ~ [J~ \ ~ /.f'1't\ Notllr IUI DICI(!RSON 1 WI My co~:U:;~;r:~~e ot Flor/cla ,-' Comm, No. DO 3CSI.S'S4, 2008 ,~- 42 JAN-25-2008 03:50P FROM:STATEWIDE ROOFING 8636885889 TO:l8l3780002l P.l FAX COVER SHEET I I I . .' Statewide Roofing and SheetmelBl, Inc, P.O. Box 2781 LBkeland, FL 33806 Phone (863) 686.1451 Fax (863) 688.5889 Send to: Attention: o ulgent o Reply ASAP o Please comment o Please tevlew o FOI your In(omlation TolDl page~, including ~ver. ?--- Commerru: ,.; II , . . ~iIL4IL~~~ iL;4~ :n.l'f.:l::JOOLO::J IYI..LLLc..r""'lI"i..LUITI JTlc.. I HL...-'=' rHO!:.. (JLfrJL Mtn '. (,.or d&h....- 5V CRIMP & MILLE"NNIUM-V INSTALLATION GUIDE ~...._~__~~-........,.._ __ _ _.....--.-" .;fJl~~. __11._ ~. I A .lb.... ----.;:j7 ""_ "'~ .._~_.. - BATTEN ATTACHMENT --- -'- > . f Uj 116" c: < w -. OJ ~ eAVE AREA FASTENER SECTION --#8 SCREW "2" OC #9 NAIL 8" OC DETAIL A SIDE LAP DETAIL MANUFACTURER FASTENING RECOMMENDATIONS --~". <Ilf--- PREVAILING WIND 1.;-;.>-' ----.....----..-... ,I ! .. , 'i/ " I'r 0,// .' / f///~,/ .' ..' fl' / t'. . . ' /.~. \..:.:_...~., ~OETAIL C ---,.......~v~ FIELD ATTACHMENr \~\,<!,~ 16 " ON CENTER ,}~",\ \~\\ DETAIL 0 \ \\ (F1IDGE. EAVES \\~~ 80 ENDLAPS) \';\\'. I \, \\ '\ "~'~' " \ .... ~ \ 'li, \.0, .. ..,..,Hw__.".___..,.._~i :>l\, STARTER "" FASTENER ED~G~ ..1 ......"A, . "..-'--- -- '- '~AI\IT~.SIPHON CHANNEL -------- ~ ,-- L L-.. DETAIL IB ,. ~ETAIL C & III ;ltEU;L1.; Make sure the deck is level and square, Batten strips are optional in new construction and reroofing over shingles. Roof deekfng integri1y should be clwcked to insure adequa1e pull out in any reroofing application. Shingles can nor be battened over i1 morEl than two layers of shingles are present. Apply batten strips according to Detail A. Banens are to be i x 3 yellow pine according to ASCE 793 Standard, Millennium recommends 30# felt to blil applied as a condensation barrier. Attachment of felt shaH be in compliance with building codes for area. An additionF.lllayer of #15 felt must be used as separation sheet if attachment at telt paper is to be done with 1/n tab. g,e~ Install Eave Drips and valley according fo details. Trim should be fastened 12" OC or 8" on center depending on zone location. Remember to use inside closure strips between Eave and Panel to eliminate water In'flltration. st~p_a; Panel placement should begin on the gable end opposite of the prevailing wind. Starter edge of the panel will be the lap edge, (Opposite of ami-siphon edge). After I.aying first panel check for squsreness. Panel 2 should be lapped over anti-siphon groove of Panel 1. (See Detail B). A minimum of 1" overhang is required at eave, Alternative method 0'1 panel placement may begin in the center of the roof. This method involves centering tha center point of the panel and working out 10 the gable or lllxterior f:'ioges. Often this method is used when 'Ihe area covered Is not divisible by 2' 01' tradiiional placement allows for a pipe flashing to occur in a side lap. Endlaps must bea minimum of 12" and t""o strips of Butyl Sealant i$ recommended 8" on uphill side of lap to keep watertight. Step 4; Fasten panel accordin~ to DetaIl C or D depending on the area of application, Nore that ASCE-798 requires additional screws in the flal area of the pan at all Ridge. Eaves and Endlap areas. Millennium Metals recommel1ds a #9 x 1.1/2 Wood Fastener. (Ultimata or Zacs are recommended on all warranteed jobs or Goastal applications). Field atta.chment should be 16" 011 center, Trim Fastening should be increased 10 6" on center In high wind areas, NOTE: Fastening in the 'flat of the panel is recognized as an alternative method of attachment and is acceptable in all areas which do not require PA-125 better known as Dade County testing. i=!.te-p' 5: Any treld cutting must be done with metal nibblers, melal snips., or blades designed for metal cutting. No cutting Should be done on roof, as It will cause iron shavings to be spread and adhere to roof panels. Proper cutting should bEl dOn$E1lCposed panel side down and field swept to remove Iron debrIS. ~aj, Install remaining accessories suCh as pipe boots. S-V profile vent, ridge caps, and gable flashing. Butyl sealant and caulking are necessary to maintaIn watertight se!als. Also inspect screw fasteners to insure that they are installed properly (See Detail G). Step 7: Field clean the roof surfaoe with a broom to be sure any iron shavings are removed. PI1"CH STRUCTURAL ALERTI 5V REQUIRES 3112 PITCH TO MAINTAIN WATER DRAINAGE. TlilS PANEL MUST BE INSTAllED OVER SOLID DECKING AS IT IS NON STRUCTURAL. APPROVED DECK SUBSTRATES INCLUDE 518" PLYWOOD OR OS8 BOARD. FJRE BARRIERS SUCH AS DENSDECK AND ROCKTEC MAY ALSO BE REQUIRED FOR CERTAIN PROJECTS. ATTENTION INSTALLER!! WHEN USING FASTENERS TO PENETRATE STEEL SHEETS T1-lE IRON PARTICLES TEND TO GO AIRBORNE AND SE"ITLE ON THE SHEET, IT IS NECESSARY TO REMOVE THESE PARTICLES TO Pt=lEVENT r::MSEDMENT AND FlUS'-- MARKS, -..- ......-. FASTENERS #9 X 1-t/~ WOOD TYPE ~.. ..- CORRECT TOO LOOSE TOO TiGHT ....... _0_- rrll ,fOt (~ .~ ~.," _.1 ~~ ~ E[lf'M MATF.A1AL EOI"M NOT AT E'l1PII4/S VISIElLE AT \lIS1~U: JOINT ?^N~IED AND IS IN"$I-IHI. NOT ENOLIG~l I"R01'1'1t)I)ING F^STCNEfl 15 COPJIi"RESSION Br.VOND EDGE 1'1I01'i:FlTY TO MAJ<i=, ^ S~^L.. OF F~Tr::NE'~, INSTALL!:C1, ~. '.- .. DfE"1l'Ama. G I ~ - . ,,-,---- ......-...-.- HIGH WIND CONSIDERATION Millennium Metals has achieved PA i 25 testing better known as Dade County on 5V Crimp. This 1est inclUdes UL 580 Class 90 testing. The testing installation was done on 5/8" plywood with a fire barrier. The plywood was attached by a #9 nail 16" on center and 4" on perimeter area. 26 gauge 5V Crimp panelS were attached 12" on center with a # 9" )( 1-1/2 Fastener anr 6" on the perimeter. Please request a copy of PA 125 tnstalla1ion instructiOnj if required for your area. -'"L."_..___________~.._...-.- _ ........ MrLLENNIUM ME1'ALS INC. 10200 EASTPORT RD. JACKSONVILLE, FL 32218 U~/L~ILUUO ~L;~O ~O~~~OOLO~ l""I.l.LLc..I~H""'.l.UITJ ITIt:.. I HL.o r~\:lc. tJ~ltJL ~\Cb C-BU'CK: .E:ngineering FL #: FL 5211.1 Date: 8/U/OS Report No.: 05-226-$Y-24--S5W Page 5of5 Specialty Structural Engineering Certificate of Authorization # 8064 Installation Method (Continued) Millennium Metals, Ine. "5V Crimp" & "MiUenmnm- V" Attached to Wood Deck Fasteners ~ #9 Hex-Head Screws With EPDM Bonded steel Washers Spaced 120 o.c.A1ong The Length of Panel Deck ~ Minimum 191:3.2" Wood Assembly Isometric View (Both Panels) ,. Re'\j~eR . elCH . PAR~S ARCtu11TECTS April 23, 2008 Mr. Mike Strickland Strickland Construction, Inc. 1441 East Gay Road Lakeland, Florida 33801 Re: 38445 5th Avenue, Zephyrhills, FL Dear Mr. Strickland: The attached sketch has a detail for the anchoring of the balcony floor framing at the above captioned address. Please install two more anchors as shown in addition ot the five existing. Attach the deck to the seven anchor supports as shown. Sincerely, Renker Eich Parks Architects U4Uz Aot- ~(Pcor7 AFtUL '2?/ ~ John Parks, AIA Archi tect G:\2007\0705 Zephyrhills SF II\Construction\manolodecksupportlet.doc ....,... 1609 Dr. M.L. King Jr. Street North, St. Petersburg, Florida 33704-4203 Telephone (727) 821-2986 FAX (727) 896-4911 Lie MC001447 HANDRAIL BEYOND WALL " ~ . I . . '- ". 1 :' ., '.... ". '.,.. ..'. .... :', " .' . . :.' ~. '. .:' "'. ';' '.A .: : . . '0 , . .. -" . : pO . : "~,,"'I "6~ ',..: ::.: :' pO ., . . EXIS11NG MASONRY WALL . . , . ,'. ,'. '.6 '. ..'... -' . .' . , , . , :.'~. ,'..'. '~ .....,.: :~."." NEW 2X6 W /BEVEL o TOP WITAPCON FASTENER : ~ ", . ~ . . EXISllNG S1EEL BEAM 1-1/2- X 4- Sll CHANNEL 5 EXISllNG 0 5'-0- O.C. INSTALL (2) NEW 1'-6- LONG SUPPORT ~RACKETS 0 EA. END 6-X 1/4- Sll PL.A1E NEW (2)2X12 PT LEDGER Vi/5/i.t BOLTS " ---- SlUCCO BACKERBOARD FRAMING CONSTRUCllON ADHESIVE NEW flOORING PARTIAL DECK SECTION DETAIL SCALE: N. T.S RENKER EICH P ARKS ARCHITECTS 11108 Ill. IiDc (9th) street Rartb, SL Petmburg. Florida, 33704 (727) 821-2911II aJ8G S1lRFRu'fT RENOVAlICWS DATE: .xl: UANClO 04-18- 2008 31445 511 ABE 2EPIIWII.L& FUID SCALE: NTS SHEET NO.: SK-6 It .. RE'JKER . EtCH. PARKS ARCHITECTS . April 2, 2008 Mr. Mike Strickland Strickland Construction, Inc. 1441 East Gay Road Lakeland, Florida 33801 Re: 38445 5th Avenue, Zephyrhills, FL Dear Mr. Strickland: Regarding the matter of installing a 3" PVC water line and a 1 Y2" PVC electrical line through the proposed column footings at the address noted above, this work has been reviewed and approved by this office. Please proceed with the work. Sincerely, Renker Eich Parks Architects ~~ John Parks, AIA Architect L.\~ ~ AC -;~ 6;, { " Cft 1 04.f)2.0f; 0:\2007\0705 Zephyrhills SF II\Construction\pipelet.doc 1609 Dr. M.L. King Jr. Street North, St. Petersburg, Florida 33704-4203 Telephone (727) 821-2986 FAX (727) 896-4911 Lie AAC001447 It . ~ RE'lI\ER . EICH . PARI\S ARCHITECTS April 2, 2008 Mr. Mike Strickland Strickland Construction, Inc. 1441 East Gay Road Lakeland, Florida 33801 Re: 38445 5th Avenue, Zephyrhills, FL Dear Mr. Strickland: Regarding the matter of installing a 3" PVC water line and a 1 Y2" PVC electrical line through the proposed column footings at the address noted above, this work has been reviewed and approved by this office. Please proceed with the work. Sincerely, Rcra2~t~ts John Parks, AlA Architect ~~ lM-~ Ac 30'-''''7 6"4 .o-z,'Df> G:\2007\0705 Zephyrhills SF II\Construction\pipelet.doc 1609 Dr. M.L. King Jr. Street North, S1. Petersburg, Florida 33704-4203 Telephone (727) 821-2986 FAX (727) 896-4911 Lie MC001447