Loading...
HomeMy WebLinkAbout08-7916 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 FIRE STANDPIPES PERMIT 7916 Permit Number: 7916 Permit Type: FIRE HOOD SUPPRESSION SYS Class of Work: FIRE-HOOD SUPPRESSION SYS Proposed Use: COMMERCIAL Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: Address: 5963 GALL BLVD ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 10-26-21-0020-00000-0021 1,975.00 6/10/2008 130.00 130.00 6/10/2008 Phone: INSTALLATION OF FIRE SUPPRESSION SYSTEM FOR HOOD Name: ABC RESTAURANT Address: 5963 GALL BLVD ZEPHYRHILLS, FL. 33542 N FIRE INSPECTION FEES 30.00 ~'n& b ~,1-1r D ~{I.. Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO NG YO R NOTICE OF COMMENCEMENT." CONTRACTOR SI URE I PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 !.13-780-0020 Date Received Owner's Name Owner's Address City of Zephyrhills Fil'e Permit Application Fee Simple Titleholder Name Fee Simple Titleholder Address Job Address Sub Division G~// g/v ,\ ~1q{~ Fax-813-780-0021 Phone Contact for Permit Owner's Phone Number I Titleholder Phone Number I II II Parcel # /lo.u.z./ ~ Lrn' ~ {)()lLJ - DOOQ:) I I I I -a:JZII D Fire Alarm Installation D Fire Pumps D Fire Works D Flammable Application- ANNUAL I I 'J? S, cru l Valuation of Project D Fuel Tanks ~ "mwWJ,ga_1f$lm~~_~~tE~f?~~~41l~L~_~~,w___l Contractor I Company I Signature Registered Y I N Fee Current Y I N .1 Address I License # I ELECTRICIANI Company Signature . Registered Y I N Fee Current Y I N I Address I License # I PLUMBER Signature Address I MECHANICALI Signature . Address OTHER Signature Address w ~ Directions: D D D D D D Bio-Hazard Waste Storage - ANNUAL Comm Exhaust Kitchen Hood/Duct Controlled Bum Emergency Generator < 30 kw Emergency Generator> 30 kw Fire Protection Maintenance - ANNUAL ~~~~ Sprinkler D 0 0 0 L-I Do ooc=J Do ooc=J [XI 0 0 0 IM<<1 Fire Alarm Hood Cleaning Hood Suppression D D D D D D D D D D D D Fumigation Tent Hazardous Material (Tier II or RQ Facility) ANNUAL Hood Installation LP/Natural Gas-Installation LP/Natural Gas-ANNUAL Sale Places of Assembly-ANNUAL Recreational Bum Sparklers Sprinkler System Installations Standpipes (Sprinkler Sys) Torch RoofinglTar Kettle Waste Tire Storage ANNUAL Company Registered Y/N Fee Current Y/N License # Company Registered Y I N I I ~1/~~r:f4f @~ Il~ . .__~=-!!.!t~.;!l~-Lta,~_-1---t Y/N Fee Current License # Company Registered Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel # - obtained from Property Tax Notice (http://appraiser.pascogov.com ) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may.be subjectto-"deed":restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for:compliancewith any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner hashired:a-contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2'500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDE AN A ORNEY BEFORE RECORDING YOUR TICE 0 COMMENCEMENT. FLORIDA JURAT (F.S. OWNER OR AGENll ~ Subscribed and sworn to (or affirmed) before me this by Who is/ar~f ,"onally 11.'10""".-5 me 0: has!hav~ produced . -- as Identification. CONTRACTOR Subscribed and sworn to (or affirmed) befOre me this by Who is/are pe nown fo ~e or has/have produced - as identification. ry Public Notary Public Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 May 30, 2008 I have reviewed and approved the plans for a commercial hood suppression system located at 5963 Gall Blvd. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. System shall be installed in accordance with all applicable NFP A codes, latest editions. 2. Exhaust fan shall stay on w/make up air shutting down on system activation. 3. All electric and gas under hood shall shut down on system activation. Inspections Required 1. Acceptance test. This would be done in coordinating with the alarm company. Fire Chief Keith Williams ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: ?-$~ Business Name: G- ~ Business Address: S~ A-tl Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES B Site Plan N/C Multi-Family/Commercial .06 sf (Minimum Charge $25.00 D Plan Revisions DBL SPRINKLER SYSTEMS B 0 - 25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM D Per Riser $50 FIRE PUMP D Per Pump FIRE AlARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS Wet $50 D~ $50 C02 ~ KITCHEN EXHAUST HoodIDucts OTHER B LP InstaJlation per tank Fuel Tank Installation (Per Tank) D Natural Gas Installation (Per System) D Spray Booth PLANS TOTALl3:&J Comments: $100 INSPECTION FEES Annual N/C 1st Re-inspection N/C 2nd Re-inspection $100 3rd Re-inspection $250 4th Re-Inspection $500 (Business closed until violations corrected) SPRINKLER SYSTEMS ~ Hydro Undergrounds $45 Hydrostatic Test $65 per system Acceptance Test $45 per system Hydrant Flow $75 Cornraaor. ~~ ~ Billing Address: ~ '/.$*'.4;; tAl!: 7~o~ n ~"'f\p.J<:i Billing Phone No.: ' I~- <;;s -3'3S-""7 Billing Fax No.: Contact: PERMIT FEE $50 $50 Sprinkler Standpipes Fire Pump \ Hoods S'1f ire Alarm LP Gas Natural Gas Fl;J8I Tanks- perlank Sparklers Fire Works Camp Fire Controlled Bum Hood/Duct Place of Assembly Fire Protection Flammable Application Waste Tire storage Generator < I<JN Generator >30 KW Bic-Hazard W~ Fumigation Tenting Torch Pot/Applied Haz. Materials B FALSE ALARM FEE 1st Alarm N/C 2nd Alarm N1C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 ~ $50 $50 $50 $50 $100 $500 $25 $100 $50 $50 Annual $25 $50 Annual $50 Annual $100 150 $100 Annual $50 $50 $100 Annual FALSE ALARM TOTAL I ~ PERMIT TOTAL Lit:J l?>o FIRE ALARM SYSTEM B System Acceptance $50 Recall Acceptance ~ OTHER ~ Fire WalllSmoke Wall $15 per wall LP Gas $25 per tank Natural Gas $25 per syam $50 ~ent 1 0'x1 0' or greater $. 1,5 per lent Fire Pump rEJ ire Suppression $30 System Acceptance B Exhaust HoodIDuct $30 Re-inspection DBL (other than annual) D Inspection scheduled DBL and cancelled less than 24 hours B Construction Insp. N/C Emergency Vehicle Ao $50 INSPECTION TOTAL~' $50 $50 $50 $50 $50 GRAND TOTAL Date: SL?D I () t{ InslJ!!Clor. '(i,- "'/ &r iUU/ -~ ~ . ~ '. . .'C .......;, . . . TECHNICAL MANUAL COMPONENTS DESIGN INSTALLATION MAINTENANCE 1-" p n,~rl;r.."h~", \,n,~, <'.lJyHV.J,t.'h' 1'rlJiT< <>" ,--ih. 0 ol~ Florida Ere ~ <.u<U- '-- t'.ffPA t: :?:>nhvrhills COMi\.JERCIALFIB..E , . EQU IPMENT CO. Exbngul~ . Exit & Emergency Lighting. Restaurant Hoods Llc.#385042000288 & Lic.#385042000188 BRUCE VARNADOE , ,_ ",' P.O t.{131 \l~4<,J:,! . . Box 2442' Brandon. R. 33509 E\.\ (liDi ()Sj,,'H,j, r IJ (I Li:I/ Specification Sheet TO FUSIBLE UNKS TO DISCHARGE PIPING I TO REMOn: MANUAL PULL STATION / rBl o 00 \ 28.125 OPTIONAL MINIATURE SWITCH CONNECTION ~ . c ~ B D +-A-4 lJ028.41PC Flow Mounting Model Point Bracket 004882 No. A B C D Capacity Weight Used I. 13.125 I. 10.625 ~I ~ PCl-160 7.00 19.62 25.37 17.31 5 33lbs. MB-15 ~ PCl -300 8.00 25.06 30.81 22.75 10 531bs. MB-15 r (FRONT) TO GAS (SIDE) PCl-460 10.00 25.06 30.81 22.75 15 83lbs. MB-15 SHUT-QFF PCl-SOO 10.00 35.81 41.56 33.50 20 1081bs. MB-1 OPTIONAL CYUNDER ENCLOSURE ALL DIMENSIONS IN INCHES ~ FEATURES . UL and ULC Approved . Complies with NFPA Standard 17 A and 96 . Meets the requirements of the Building Officials and Code Administrators (BOCA) . Approved by the City of New York Material and Equipment Acceptance Division (MEA) ~ GENERAL The KITCHEN KNIGHT~ 1/ Restaurant Kitchen Fire Suppression System is a pre-engineered solution to appliance and ventilating hood and duct grease fires. The system is designed to maximize hazard protection, reliability, and installation efficiency. Automatic or manual system activation releases a throttle discharge of potassium carbonate solution on the protected area in the form of fine droplets to suppress the fire and help prevent reignition after the discharge is complete. r SYSTEM OPERATION The KITCHEN KNIGHT II Restaurant Kitchen Rre Suppression System has been designed for protecting kitchen hood, plenum, exhaust duct, grease filters. and cooking appliances (such as fryers, griddles, rangetops, upright broilers, charbroilers and woks) from grease fires. The versatile state-of-thecart wet chemical distribution technique, combined with dual, independent activation capability _ automatic fusible link or manual release - provides efficient, reliable protection the moment a fire is detected. Once initiated, the pressurized wet chemical extinguishing agent cylinder discharges a potassium carbonate solution through a pre-engineered piping network and out the discharge nozzles. The wet chemical discharge pattern is maintained for a duration of time to ensure suppression and inhibit reignition. Expanded capability provides remote manual actuation, gas equipment shutdown, and electrical system shutdown. This optional equipment will enhance the basic system functions and be applicable when designing custom configurations to suit a particular customer's needs and/or comply with local codes. The operating temperature range of the Pyre-Chern KITCHEN KNIGHT 1/ System is 32"F to 120"F (O"C to 49 "C). 8/112005 PC2oo1192(2) The file &uppf! . Jill sysIem should be of1be sIlnd ~ wet cheMlcBlpI8...:1~""naz:zI8~~by ~Ac:adxlndialddeUIIIIli~I8~In~.. wiIh I8IIIy Sp- III ...... .....-c-eo1G" end 4Ih!I!I be 1-.t _the .. pIBIIIIIIIIc .11 11I~ d8IIice tar....... 1'h8~ .... bean . .,... _ 01 the c:anIRII.... r... 1'h8'" cr..w...... ... ayInder.... be a DAT.-nd8d....._ lIIamd..... of 225 pII(g. end a..-........... be........ an" 0JIndIr "... for....II~..oQ. 1be.,...... be........ of......-c and___-~~~.,.....,.......pIDlIIdBdby- ....D{JoI..lUJ1berol...... ......."'. ..-*iidlIn..... an a ... 11' , ........1nput.. to.. ccnIUI '-L...... -~ shaI be provided byllllnQl a..... an the pdaIIIiy........by ~ -'" .. ~ 1. CYUNDER COHJ'ROL HEAD-1nIBgnJI d8sign I8qUi8S no sepe.* ........... c:yIncIes:. ~..... CIbIa...... lines far -*'... fu8IbIe InIc8 end apIianII naoI8 puI aIIIIIDn pnMde _Idled me&8IA of""" An....,..~ -......... .... .......... ~ moplan for...........fuIIbIe b anc:I. ~.. an Iac8I ClIDCIIe. CI8Il be.... In... of 8 ..... nwnueI pu118IBIIan. ~ faaIpn:d IBl:hnIque tDr echIlM1g nee 1 n I _y Input.. CIbIe IiInIIIDn. 2. PIPING-UabIII8IWledPl*vDllitWrllk...... - ~"'~-tdelfgn end. - - .... ......110 ....._ ___ toGDllDBllt...... ... .........10 ~..... tIII8III ~.......... SdI8duIa40 bIedc IRJn, ~ or... I I...... prpe -.a be ... .. 3. CYl.NlEFIS-~ Pym.a.n ~l '.., CWbu...... c:M...... ..... .... 81225 pIIg. 1nl:IudIs...... JI8UII8 far ... a.......... c:hecIra. 1.6. s.o. ..... end 8.D-g11aa.... JIRIIllIde 5. 10. 15. end 2D aa. ... ClJlI8AIUI!IMI*'-_ ...... 8.... renge of ...6JaIb...-. 4. JI(l77I~ - CluJ be IxIId or lied will a..... ...... tIIIwIing Ihe IIQZ2Ie to be toIaIIId BfIPlklud.t>A.~ .. ta 81 cfnIaIaoa.. -- -r--"- ---1':",- ,.- ---..- ....._... _ _____ __.___ __... _~_. &ne to 1he canInII head. 1bB 8JIIIIlm .... haVB ~ 1BsIBd 10 Ihe Ul SIandan:J for Fire ~ ~- for Ph....... of ResI8unmt Coddno.Area. UI.3DO. and I.III8d by lJwlde.w4IaoLabot..... Inc. It 8haII be inIIIIIIlId In ~1Ce will.......... File PI.... ~~aIIon Sl8uda.d No. 17A Wet CIBnIc8I ect.",wS)*.:n... end No. 96 - . ___ for.. 1n.1" - - -. of EIMJnB1tb'the Removal at SIiDce ... __.......".. flam eamo...... CaoIdng EquIpment, end caqIIy...... ~ 8IdJr8lllle aodIIs and ....... ReIer 10 ~ J01 De EN IQIBiTI R8IIIIuImt FII8 8uppr;elslOlI SJ*m ....... Pert No. 551274. far dBI8IIed ~ and - ~''''''''JC6 iJIIn.JcIans, /'" ./ 5. REMOTE MANUAL PUU.SDmON'n~ apelaliug fnBIIucIIans lIlIIh dcII.tie acIIan release 8Vdds caI1IIess system dIlId~ MDimum i. - r ... d 150.. cable run wJIh 1116 in.. CllI1Ie end 40 comer....,. appIJ. A......,.., .. cable iq)ut "'10 1ba QJInder canInlI.... pIUlIIdBs a 1nJe beck up in the eII8nt.. fa8IbIe InII8 818 fouled. B.. AJSIBLE l.N( Ul::11:\i11Ulll EQUIPMENT -ADco,....~ both .... end tIImIn8I pIIIDeI_1l to mWI.b IIWenby 1R18ImpIfy ......... M .. r n I<.}o .COmPaIBIIB _Included tDr eIIcienl ! .... ... . . - r -.. FulIIbIe iniss RIIIIId for maximum ...... .._..... must be 0IdInd 1IIIp8I8IeIy. M8Icimum .....- of 2D fcJIIbIB inial an 8 150" cable run will 40 c:omsr ....,. pnM:ie ~......... CCMMB(!or 7. AU'RJIMI1C GASstIJT.OFFVAlllE-~wIIl .....-_.. .........10.. 8hut 011 of fueI_ .....Ib.d by JlFM 17A. C8n "18lIIIl8l canImI.... .... RIgUIar .........n: u 1lII... CII-* lor CCIRwfilo.tc& to .mea 1lIc:triciao.. .......... A, - - .... 01100 ft. CIIIlIe JUI1 wIIb SO IXlITIIIr pulleys pnJllIde ---,..,.., 8. CORM:R PUU..EYSAND ACCESSORIe&- De8Ig..-j 10 ensure 18111b18....... funcIan a1Bstlld by lIndeIWiI..... I..aboIaIooIes. /. Pyro-Chem Kitchen Knight II PCL-300/460/600 Nozzle, Coverage Summary Sheet KITCHEN ~.~~ KNIGHl: II Jj- e Width Length Min. Max. Nozzle Flow (In) (In) Height Height Appliance Type Points Max. Side Area Sq. In (in) (in) Deep Fat FJyer - Vat 2H 24 48 2 19 1/2 19 In. Deep Fat Flyer (Low PraldmiIy) - Vat 2L 13 24 Deep Fat F/)'8r - Drip Pan (Vat 18" x 18" max.) 2H 24 48 2 Zl314 500 Sq. In. Deep Fat F/)'8I" (Low ProxImity) ~ Drip Pan (Vat 18" x 18" max.) 2L 13 24 Deep Fat F/)'8r - Drip Pan (Vat 19 1/2 x 19" max.) 2H 24 48 2 25 3/8 495 Sq. In. Deep Fat Fryer (low Proximity) - Drip Pan (Vat 19 112" x 19" max.) 2L 13 24 Two Burner Range 1H 40 50 1 12 28 In. Two Burner Range (Low Proximity) 1L 13 24 Four Burner Range 2L 2 28 28 In. 34 48 Small Wok 1H 24 48 1 24" dia. 6" deplh Small Wok (Low ProximIty) 1L 13 24 Large Wok 2H 24 48 2 30" elia. S" deplh Large Wok (low Proximity) 2L 13 24 Small Griddle 1H 24 48 1 36 1080 Sq. 'n. Small Griddle (low Proximity) 1L 10 24 Large Griddle 2H 24 48 2 48 1440 Sq. In. Large Griddle (Low Proximity) 2L 10 48 Gas Radiant Char-Broiler 1H 24 48 1 26 624 Sq. In. Gas RadIant Char-Broiler (Low Proximity) 1L 13 24 Large Gas Radiant Char-BmiIer 2H 36 48 2 36 864 Sq. In. Large Gas Radiant Char-Broiler (low PraldmiIy) 2L 13 36 Lava Rock Char-Broiler 2L 2 26 624 Sq. In. 15 35 Natural Chan:oal Char-Broiler(max. fuel depth 6") 1H 24 35 1 24 480 Sq. In. Natural Charooal Char-Broier (Low ProximIty) 1L 15 24 Mesquite Char-Broiler (max. fuel depth 6j 1H 24 35 1 24 480 Sq. In. Mesquite Char-Broiler (low ProximIty) 1L 15 24 UprightISaJamander Broiler 1L 1 36W 280 Front edge; above !he grate Chain Broiler (Inlemal Chambeq 1L 1 ZlW 380 Front edge; 1-3" above !he chain TIt SIdIIetJB/aisin Pan Covetage limilaIions are based on fiyer sizes includlng'!he drip boards. Exception: Tilt SkiIIeIs and Bral&ing Pans may exceed maximum of 6 sq. ft. - ,- ,- *"~~~~~. Nozzle Flow Width Length Nozzle Placement (See Plenum Type Points (It) (ft) manual for more detail) SIngle BankJV Bank 1H 1 4 10 (J' - 6" from end of plenum -- .. .' lfi " - " Nozzle Flow Max. Side Perimeter Diameter Length Duct Type Points (in) (in) (in) (in) ReclangIelCiraJIar 2D 2 34 100 31 718 UnJinited RectanglelCiraJlar (2) 2D 4 51 150 47 1/2 Unlinited PC2001189(2)