Loading...
HomeMy WebLinkAbout08-7849 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 FIRE ALARM SYSTEM PI';RMIT 7849 Permit Number: 7849 Permit Type: FIRE ALARM SYSTEM Class of Work: FIRE ALARM SYSTEM Proposed Use: NOT APPLICABLE Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: Name: ZEPHYRHILLS TOURIST CLUB Address: 5216 7TH ST. HISTORIC ZEPHYRHILLS, FL. 33542 4,400.00 5/30/2008 200.00 200.00 5/30/2008 INSTALL FIRE ALARM Address: 5216 7TH H T RIC ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 11-26-21-0010-16700-0180 Phone: FIRE INSPECTION FEES 50.00 .,.--::- () c~~ J~ (~ Ina FIRE ELEVATOR RECALL Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." 1 CTOR SIGNA URE I PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOnCE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 The undersigned hereby gives notice that ~ wiD be made to certain real ~1 and in accordance with Chapter 713. Florida Statutes. the mUowing iIlfcnwation i; provided in this Notice of Commencement 1. legal desaiption of (InClude street addJ~. if available):b ~ r' , ~ -\ Co \ v... \s- ' h ., ,- .3 36 v Z '" ,,<j'i l. I.. d. Cr.oj .}I,. uQ. liJT:'1 Pf, 4;)lQ ~ 2. General ~ of ~ --'- "'." "" \ l /. P-e... A \"u':':: 'i:,'t:'k~ . 3. Owner inl'ormalion - name and adchss: :1(-<"" "" Clu \) ":>,1t.D '1i'hS\-. ~0"rhrl ~ _: H ~6 Interest il property: ,.. 10 00 Name and address of fee simple ti1IehoIder (If oIherthan Owner): __ Rcpl: 1183289 Rec: . DS: 0. 00 IT: 0. 00 - OS/29/08 Dpty Clerk Permit No. State of~ County of Cl SGLj Tax Folio No.. I 'I ~lO 'J-\ 0016 I (9.lC6 0 1~6 NOnCE OF COMMENCEMENT 1111I111111111I1111I1111111111111111111I1111I11111I11111111I 2008080071 R 4. Contractor - name and adcIr~ = Phone number, ~ ~A- 5~ 7 - 59914 5. Surety - name and address: SflEClAL TV ELECTRONIC '79~Y~:~~E~~, - DADE CITY, FLAit1humber ,-? 5~ . 5;)../ _ t, 0 ~ <' Phone number Fax number Amou1t of bond: $ 6. lender- name and add~ Phone number .. Fax number. 7. Persons wiIhln!he SIaI8 of Florida ~ by Owner.-. whom noIIces... olher documenIs may be served as provided by Section 713.13(i)(a)7., Aorida Statutes (name and address): Phone number Fax number 8. In addition to himself. Owner designates of to receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Sta1utes. Phone number Fax number 9. EocpiraUon dale of NoIIce of Commencement (lhe expiration dale is 1 year fian lhe dale of recadIng unless a different date is specified). ~~ Swan to and suhsaiJed bcfuremedDs.o:ld dday of /J 4ff- ~ 20{) ~ . .'" ) A /1 / (-/'(~ ')buc..<<~_~.C$t/ MyComm;ssion Expires: 4/.ai:? ao:; Notal)' Public / , . l~~<if.~:;:~.}> KATHLEEN SCHNEIDER i*: :*E MY COMMISSION # DO 408569 ~"......-$""~ EXPIRES: AprilS, 2009 ~p.r.,r.I." Bonded Thru Notary Public Underwriters ISle.. o UlI'T1 ;:u ,0 tD ~" .... ,'" ISI-t _ICXI:i --'~:D CD~_Z .I:;It~ " ~:D ~(/) (") o ,,~(") Cl 0 c: ~Z ~:J W--p CD~ .... Fire Chief Keith Williams ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 .Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: Og-6~ Bus~nessName: ~JSI $~~ Busmess Address: )(;. . cS Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES B Site Plan N/C Multi-Family/Commeroial .06 sf (Minimum Charge $25.00 o Plan Revisions DBL INSPECTION FEES N/C N/C $100 $250 $500 $100 Annual 1 st Re-inspection 2nd Re-inspection 3rd Re-inspection 4th Re-Inspection (Business closed until violations corrected) SPRINKLER SYSTEMS ~ Hydro Undergrounds $45 Hydrostatic Test $65 Acceptance Test $45 Hydrant Flow $75 per system Billing Phone No.: Billing Fax No.: Contact: PERMIT FEE $50 $50 $50 Fire Alarm LP Gas Natural Gas F~el Tanks- perlank Sparklers Fire Works Camp Fire Controlled Bum Hood/Duct Place of Assembly Fire Protection Flammable Application Waste Tire Storage Generator < t<JN Generator >30 t<JN Bio-Hazard Waste Fumigation Tenting Torch Pot/Applied Haz. Materials SPRINKLER SYSTEMS D 0 - 25 Heads $50 D 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 FIRE PUMP o Per Pump FIRE ALARM SYSTEM ~ _ 25 Devices $50 FIRE ALARM SYSTEM 26 plus Devices ~.P{s~~m Acceptance ~- PPRESSION SYS~II Acceptance $50 ~ Wet $50 OTHER Dry $50 ~ FireWalVSmokeWall $15 per wall C02 $50 LP Gas $25 perlank Other $50 Natural Gas $25 per system KITCHEN EXHAUST o HoodIDucts OTHER B LP Installation per tank Fuel Tank Installation (Per Tank) o Natural Gas Installation (Per System) o Spray Booth $50 ~ Tent 1 0'x1 O' or greater Fire Pump Fire Suppression System Acceptance B Exhaust HoodIDuct Re-inspection (other than annual) $50 0 Inspection scheduled DBL and cancelled less than 24 hours D Construction Insp. N/C D Emergency Vehicle Ao ~/ PLANS TOTAL~NSPECTION TOTAL~. Comments: per system $50 $50 $50 $50 $15 $45 $30 per tent B FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 ~. $50 $50 $50 $100 $500 $25 $100 $50 $50 Annual $25 $50 Annual $50 Annual $100 150 $100 Annual $50 $50 $100 Annual ./ PERMIT TOTAL~ 'Q~- ~ FALSE ALARM TOTAL I $30 DBL GRAND TOTAL Date: Insooctor: -~ 813-780-0020 Date Received Owner's Name Owner's Address City of Zephyrhills Fire Permit Application jf16fl Fax-813-780-0021 Phone Contact for Permit Owner's Phone Number II II I Titleholder Phone Number I II II 1~4'/L15r I <.5210 7fA I I C/~b .)fae:r: r Fee Simple Titleholder Name Fee Simple Titleholder Address Job Address I Lot# Sub Division ~2./~ -; I-A ,f-r,..c ~r Parcel # D D D D D D Contractor Signature Address I ELECTRICIANI Signature Address I Bio-Hazard Waste Storage - ANNUAL Comm Exhaust Kitchen Hood/Duct Controlled Bum Emergency Generator < 30 kw Emergency Generator> 30 kw Fire Protection Maintenance - ANNUAL ~~~~ Sprinkler D 0 0 0 L-J Doooc=J Doooc=J Do ooc=J Fire Alarm Hood Cleaning Hood Suppression Fire Pumps Fire Works Flammable Application- ANNUAL D D D D D D D D D D D D Fumigation Tent Hazardous Material (Tier II or RQ Facility) ANNUAL Hood Installation LP/Natural Gas-Installation LP/Natural Gas-ANNUAL Sale Places of Assembly-ANNUAL Recreational Bum Sparklers Sprinkler System Installations Standpipes (Sprinkler Sys) Torch RoofingfTar Kettle Waste Tire Storage ANNUAL Company Registered License # Company Registered License # 0' Fire Alarm Installation D B D Fuel Tanks D Other: I I /~f:kf I Z:' 7ft! tI "''' Valuation of Project PLUMBER Signature Address I MECHANICALI Signature . Address I OTHER Signature Address Directions: Company Registered License # Company Registered License # Company Registered License # I ?/f!"CI ~;. /1- Y Eki~' c :fv.,;h-..,S Y I N I Fee Current _:t...! N _ I EF ()O~ /C)cr'~ I Y I N I Fee Current Y I N I I Y/N Y/N Fee Current Y/N Y/N Fee Current Y/N Y/N Fee Current Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10-14 days for review after submittal date, Parcel # - obtained from Property Tax Notice (http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may.besubjectto'''deed'';restrictions'' which may be more restrictive than County regulations. The undersigned assumes responsibility for:compliancewith any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired :a-contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contra9tors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW (Chapter713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S.117.~} /J OWNER OR AGENT -?'t:- '~~ CONTRACTOR L ~ Subscribed and sworn to (or affirmed) re e this Subscribed and sworn to (or affirmed) before me this by by Who is/are personally known to me or haslhave produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 May 9, 2008 Plan Review Comments I have reviewed and approved the plans for a fire alarm system located at 5216 7th St. (Tourist Club) under the following conditions. My comments have been placed below. Please contact me if you have any questions with regards to my comments. 1. Alarm shall be compliant with NFP A 72, 2007 edition. 2. Provide a zone map located at the alarm panel. 3. When the alarm is silenced, strobes shall remain flashing. 4. Label detectors and pulls to coincide with the alarm panel. 5. Documentation shall be provided at acceptance test to show monitoring company is a listed central station. Inspections required: 1. Acceptance test. (includes pulls, detectors, audible/visual, ducts, fire/smoke doors, telco, battery, penetrations) !iPECIALTY ELECTRONIC !iYSTEMS..INc. L1C.#EF00010463Si!-S67_S996 P.o. BOX 41 - DADE CITY, FLORIDA 33Si!6 - FAX 3Si!-Si!1-60BS GAMEWELL FIRE ALARM SUBMITTAL FOR TOURIST CLUB ZEPHYRHILLS, FLORIDA APPRfJVED . ....". /)11 '~lre ~1"N'h,,1 r 'fZ 1. "I '" 'r 1V tel~. iQ.l u,. _enUy'Tnl],; , I I:' ., N't,' (;D~'r:le"t.' . .)vide,' Wj~l"fV) 5l9f CJ2 ACCES!i CONTROL - BURGLAR ALARM - ccrv - FIRE ALARM -GATE OPERATORS Gamewell .-:'":'1 FIRE COi'HROL I.Jl.:lJ INSTRUMENTS by Honeywell E3 Slrils™ Clntrll PIIII Description r' GAMEWELL-FCI ' I 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 Speci1kations are for information only. are not intended lor installation purposes. and are subject to change without notice. tto responsibility is asscmed by Gamewell-FCI lor Iheir use. '-- @200iby Honeyweil International In.;. M rights reserved. www.gamewell-fcl.com 9020-0637 Rev. G page 1 of 2 . -- -../ The E3 Series™ Expandable Emergency Evacuation Sys- tem by Gamewell-FCI is in the forefront of the latest gener- ation of fire alann control panels. Employing the new high- speed Velociti™ sensors, the E3 Series provides previ- ously unattainable polling speed and response together with the flexibility demanded by today's emergency evacu- ation systems. In addition to their high-speed polling rate, the Velociti™ series of sensors feature bi-polar LEOs that flash green for normal polling, and light red steadily to indi- cate an alann. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric: LCD display that allows 40 characters to be user-defined for customizing installations. Up to six (6), keyboard LCD displays may also be remotely located in addition to five of the familiar LCD-7100 remote displays, allowing for instant system status information to be avail- able in any desired area of an installation. A high-speed 32-bit processor easily tackles a wide array of applications from small office buildings to sophisticated high-rise installations. 54-node networking is made possible by 625K baud/ARC- NET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. The basic E3 Series is equipped with an ILI-MB-E3 Intelli- gent Loop Interface-Main Board, Intelligent Loop Interface Expansion Board, and ASM-16 Addressable Switch Mod- ule that featu res sixteen (16), software programmable switches, each accompanied by red, green and yellow LEOs that can be programmed to indicate operation of the switches. Additional ASM-16 mOdules may be added to expand the operation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 Series control panel with two (2), additional signaling line circuits. The layout is similar to the ILI-MB-E3 with the exception that a number of components are omit- ted. It OCCLJpil3s one node on the Broadband network. E3 Senes'" and Velociti'" are trademarlts af Honeywellnternationallnc. Expandable Emergency Evacuation System Features E3 Series · Usted under UL Standard 864, 9th Edition. · UL Usted for smoke control (dedicated and non-dedicated) when properly configured. · Styles 4, 6, or 7* signaling line circuits. · Two to 128 SLCs each supporting 159 sensors and 159 modules. · 625K baud ARCNET communications using wire, fiber, or mixed configurations for installation flexibility. High-speed 32 bit processor. . 4100 event history log. · Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming. · Supports up to sixteen (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI-MB-E3. · Two (2), Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit. · Integral city connection. · Flexible 115,200 baud high speed RS-232 interface. . 40 character user-defined text per device. . Supports up to five (5), LCD-7100 displays and six (6), LCO-E3 keyboard displays per ILI-MB-E3. 'Style 7 wiring requires the use of System Sensor MSOOX Isolator Modules. An ISO 9000-2000 Company SIGNAUNG @0MEA '. LISTED APPRO... Appro'ed S1869 3025415 231~6'E 71&$.0594:2" 71&5.0594:211 Cit,,'of Cbicago City of AppTo...ed Denver Cia.. 1 Approved Clau2 Hlib Ri.. Description (Continued) Features (Continued) Each ILI-MB-E3 can support as many as sixteen (16). ANU-48 LED Driver modules supporting hundreds of LEDs on a 3rd party graphic annunciator for remote annuncia- tion. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS- 485 serial interface. Cabinet B contains a space for the ILI-MB-E3, PM-9 mod- ules and batteries set inside the backbox. Additional mod- ule options mounted on the back:box include the DACT-E3, RPT-E3 and ILI-S-E3. The 2-bay inner door houses one (1), LCD-E3 module and one (1), ASM-16 module. Velocitl™ Intelligent Sensor Features: . Poll 318 devices in less than two (2) seconds. . Activate up to 159 outputs in less than five (5) seconds. · LED's blink the associated device address during walk test. . Fully digital, hi-precision protocol. · Up to 9 levels of senSitivity adjustment. . Pre-Alarm adjustable betwel3n 15 levels for both Alert and Action. . Day/night automatic sensing adjustment. . Sensitivity windows: - Ion 05 to 2% obscuration. - Photo 1 to 3% obscuration. - Laser .02 to 2% obscuration. - MCS Acclimate2F .5 to 4%, also self-adjustable options 1 to 2%, 2 to 3%, and 3 to 4%. - HARSH 1 to 3% obscuration. . Drift compensation. . Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor. · Optional programmable switches can be c;onfigured to enable, disable or group any combination of output devices. . Integrated point or Grouped Cross Zoning allows for numerous del/ices installed at any location to cooperate and determine alarm condition. . Automatic detector sensitivity testing. . DIRTY and VERY DIRTY detector maintenance alerts. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series expandable emergency evacuation system offers four (4), cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 193/8" (49 em) wide wall-mounted enclosure. Cabinet A includes the following four options: · Cabinet A 1 inner door mounted to the backbox. The backbox houses one NGA module. · Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. . Two or three-bay inner door mounted to the backbox. The backbox typically houses one (1) LCD-E3, or one (1) NGA. and one (1) or two (2), ASM-16 modules. Specifications Both Cabinets C and D include tile following: · Pre-assembled outer door that gives visibility to the fire fighter's phone handset and a microphone voice messaging system. · Two inner door panel selections that may contain optional modules to meet the facility operation requirements. Operating Voltage: 24 VDC Operating Temperature: Not to exceed the range of 320 to 1200 F (0 to 490 C) Relative Humidity: Not to exceed 93% non-condensing at 900 F (320 C) Ordering Information For instructions on installing any of the above E3 Series cabinets, refer to the E3 Series Expandable Emergency Evacuation Installation/Operating Manual Part Number: 9000-0574. Model Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board LCD-E3 LCD-E3, LCD Keypad Display RPT-E3-FO Network Repeater (fiber and twisted-pair) RPT-E3-UTP Network Repeater (twisted-pair only) DACT-E3 Digital Alarm Communicator Transmitter ANU-48 ANU-48 LED Driver Module ASM-16 Addressable Switch Module NGA LCD Network Graphic Annunciator PM-9 Power Supply Module LCD-7100 Remote LCD Display For additional information on the cabinets, refer to the E3 Series™ Cabinets data sheet (Part Number: 9020-0649). GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA' Tel: (203) 484-716'1' Fax: (203) 484-7118 " 9020-0637 Rev, G page 2 of 2 www.gamewell-fci.com I Elr~ INSTRUMENTS LCI-E3 by Honeywell Description LCD Keypad Display The LCD-E3 provides the main panel display of the E3 SeriesQ!) Expandable Emergency Evacuation System with indicating LEDs and operating switches. Up to six (6), LCD-E3 displays may be locally or remotely located from the panel via a local RS-485 bus of the ILI-MB-E3 sub- assembly. I' =~ f;.',.,J,:'''}',i~T7'':' :''; .' .. "',' The LCD-E3 includes an LCD display for the system status and the following switches and LED indicators: Switches . Alarm acknowledge . Trouble ;3cknowledge lCD-E3 . Signal silence . System reset/lamp test . Function buttons: - menu/back - back space/edit -OK . 12 button keypad Features . Listed under UL Standard 864, 9th Edition LED Indicators . AC Power On . Alarm . Supervisory . System Trouble (green) (red) (yellow) (yellow) . Power Fault (yellow) . Ground Fault (yellow) . System Silenced (yellow) . Provides an 80-character display of system events together with indicating LEOs and control switches Installation . The ILI-MB-E3 can support up to six (6), LCO-E3 displays, any or all of which may be remotely located via the RS-485 serial interface The LCD..E3 is adaptable for installation in any of the following E3 SeriesQ!) System cabinets: . "A" size cabinet, inner door (E3ID2-A) . "A2" size cabinet, inner door (E3ID-A2) . "8" size cabinet, inner door (E3ID2-8) . "COO size cabinet, inner door (E3ID2-G) . "D" size cabinet, inner door (E3ID2-D) . Easy to read backlit LED display, low power consumption Ordering Information Specifications Model LCD-E3 Description LCD keypad display Operating Voltage: 24 VDC FWR (from PM-9 power supply) Operating Current: 0.024 amp. Alann Cum~nt: 0028 amp. Operating Temperature: 32. to 120. F (0. to 49. C) Relative Humidity: 0 to 93%, non-condensing at 90. F (32. C) E3 Senesill and NetSOLoill are registered trademarks of Honeyo.>e" Intemationallnc. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 Specifications are for infoonalion oniy, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by GIlI11e'MlII-FCI for their use. @2oo7byHonej"Nelllntemalionallre, All righl5 reserved. www.gamewell-fci.com 9020-0606 Rev. e1 page 1 of 1 An ISO 9000-2000 Company ~G~B.t~ CI,>.f \Z!::I ~MEA ,;:':;..e., Cblcqo City.f LISTED .......ItOVID Appn:wed (... .~~. Approved. Denver 51868 3025415 2Z1-Ge-e 71u.0&9":211 =~ ApproVed 1165-0694:261 HilIl R_ .-::rI FIRE CONTROL ~ INSTRUMENTS' by Honeywell .... Description ASM-16 Addressable Switch Module The ASM-16 is a configurable switch input sub-assembly with sixteen (16), switches and forty-eight (48), status LEDs and may. be remotely located via the RS-485 serial interfacE!. Each ASM-16 addressable switch module has sixteen (16), push-button switches that can be programmed to serve any function the application demands. ~ :?i'l ~ ~ ~1 The ASM-16 Addressable Switch Module is a component of NetSOLOTM and E3 Series™ fire alarm and voice evacuation systems. It serves as the point of interface between an operator and the system's audio evacuation, fire fighter intercom, and building control circuits. Front View Rear View Features An ASM-16 switch can be programmed as a speaker circuit switch, fire fighter phone switch, an auxiliary control switch using a bank of three (3), switches (one switch each for on-off-auto functions), or switches with custom defined functions (e.g. system reset, system silence, system acknowledge, all-call, phone patch, lamp test, alarm tone on, manual select, etc.). Each ASM-16 switch also has three (:I), fully programmable LEOs in red, yellow, and green. These LEOs can be programmed to work in concert with their associated push-button switch or they can be made to work independently as status indicators (e.g. on, off, normal, etc.). . Each INI-VGC supports up to sixtE!en (16), ASM-16 switch modules for a total of 256 switches. · Each ILI-MB-E3 supports up to sixteen (16), ASM-16 switch modules for a total of 256 switches. · Each ASM-16 switch has three (3), fully programmable status, indicatin!) LEOS: red, yellow, and green. · All switch functions are fully software programmable. · Slip-in label inserts allow easily modified switch designations. · Listed under UL Standard 864, 9th Edition. An INI-VGC assembly or ILI-MB-E:3 can accommodate up to sixteen (16), ASM-16 modules for a total of 256 switches and 768 LEDs. Ordering Information Specifications Model ASM-16 Description Programmable switch module Operating Voltage: Operating Current: Operating Temperature: Relative Humidity: 24 VDC (nominal) (from PM-9 power supply) 0.011 amp (with no LEDs lit) 32" to 120" F (0. to 490 C) o to 93% (non-condensing) at 900 F (320 C) E3 SeriesThl and NelSOLOTM are trademarks of Fire Conlrollnslrumenls. An ISO 9001-2000 Company SIGNALING @0 liSTED APPROVEO 81865 3017416 Cil) or Chi('a~o MEA Approv"d Appr::l...ed - Class 1 217.03-E 06911.0694257 . Class 2 . High FUse City of DENVER Approved /- ._----_._---_._-~------~--_._--~-~ --'I I I 'I I GAMEWELL-FCI 12 Clintonville Road. Northford. CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only. are not intended for installation purp,)ses. and are subject to change without notice. No responsibility is assumed by Gamewell.Fel for their use "'2006 Gemewell-Fe!. All rights reserved. www.gamewell..fcLcom 9020-0554 Rev. H page 1 of 1 \.. Gamewell r:':n FIRE CONTROL - I.i..:U li\JSTRUMENTS Ill-MB-E3 by Honeyvvell Series Description 11I-MB-E3 The Intelligent Loop Interface-Main Board (/L1-MB-E3) is the main interface for the E3 Series™ product line. With its state-of-the-art 32 bit RISC processor, this compact "panel on a board" provides a powerful addition to Gamewell- FCl's single pair conductor solutions. This intuitive design provides two (2), signalin';J line circuits, two (2), notification application circuits, local energy city box output, auxiliary relay functions, and auxiliary power output. These features, combined with built-in nE,twork and serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to fire alarm panel design. Intelligent Loop Interface-Main Board Il'~]J~~~~~~ff~'i"'~<~'~~~=:'1 :""it. 7~ ':~:-F;"'~;x."'" ;~-fi1.::',-.! _< _. _.~r ..".- ,.,oil!';'.!". ~'.~i-;'\ 1:;;,..'-6;-'-'..!..,.'.. :~1 . ., .;or-' -.. ".,. . I ~ ~ "~"J 1 . "'-./. I . _I ..i-.!:\- ....1. ., '>"j '.0- "__ . 1:;:~'~j;I~:j,i ill' i-li t}i't~ :;1 ~~:~:pli;.'.,'~;.J:: . ~,; '.llt.:... ~ '.: . . . ~i.~. .!;~~tl-~ _: ~:::.) -',.-3ij I ""',. .....:."'t....'-~ ~-. -,~~ 0>'"00' J ;.......;--;, "'1' ;""'" ~. _.~. .....",... I~. .l I'....... . .. " '4 - . I~ " !..~';!!~t.-;~,. 1_~:.:..::.:...'"_. ~_':- ILI-MB-E3 Features The ILI-MB..E3 is network ready and occupies one of 64 nodes, operating at 625K baud. When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When transmitting to remote locations, the optional RPT-E3 pro- vides the ILI-MB-E3 with valuable signal boosting and tran- sient protection, as well as connectivity using both wire and fiber-optic cables. IL.I-MB-E3 and 11I-S-E3: . Listed under UL Standard 864, 9th Edition. . Network ready integral 625K baud ARCNET. . 115.2K baud RS-232. . Signaling line circuits with: - Two (2), Class A, Style 6, 7* or Class 8, Style 4 circuits. - 40 Character user-defined text per device. - Capacity of 159 sensors and 159 addressable. modules per circuit. . 4'100 event history log. *Style 7 wiring requires the use of System Sensor M500X Isolator Modules. ILI-ftIIB-E3 Only: . Two (2), notification appliance circuits, Class "A", Style Z or Class 8, Style Y rated at 2.0 amps. per circuit. . RS-485 supporting sixteen (16), ASM-16 switch mod- ules and/or ANU-48 LED driver modules. . Aiarm, trouble, and supervisory dry contacts Form "C", rated at 2 amp. @ 30 VDC (resistive). . S:Jpports six (6), locallremote LCD-E3 annunciators and five (5), LCD-7100 annunciators. The ILI-MB-E3 provides two (2), signaling line circuits and terminals for the connections to up to 159 detectors and 159 modules per SLC in Velociti. In clip mode, each SLC supports tl9 detectors and 98 modules. The RS-485 inter- face can support up to a total of sixteen (16), ASM-16 and/ or sixteen (16), ANU-48 remote LED driver modules. The ILI-MI3-E3 relay outputs include system alarm, super- visory, and system trouble contacts. The ILI-MB-E3 pro- vides output I'or a local energy city master box or remote location which is non power-limited. All other wiring is power-limited. An ISO 9000-2000 Company . ~~~I 1 I 12 Clintonville Road Northford CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 Speeiflcallons are for information only, are not intended for ir,stallatlon purposes. and a;e subject to c~ange without nollee. No responsibility is assumed by Gamewel~FCI for Iheir use. ,.,1 l @2006 Hone)'YIelllmematlonallnc. All rights reserv~j. www.gamewell-fCI.com 9020-0605 Rev. E page 1 of 2 . --~--~------------~----~---~- SIGNAUNG @<S>MEA LISTED APPi;lOVED P.pPfOVell Appro...ed Denver S1869 30250415 231-oH 7165-0694:268 ~:::j Approved ;165-0694:269 High Rl... City of Cbica.o City of E3 Series'" ana NetSOLO'" are trademarks of Honeywelllnlemalionallnc. ''', ~ . I. :.~; - ~ .- . :~j~,,-- ~*~~f . < ~'~';:'C"" '~"~~-'/ I . r.:-:er ~;: ',~;:.-; . ~i; Specifications i!i~l:<' - :6. : ~..,. II , , , '::~:;':~i: _it-:r:\~~:~f~iJ ~--~;~:j~~~.~~.~",: Operating Voltage: 24 VDC FWR (from PM-9 Power Supply) Operating Current: 0.081 amp. Alanm Current: 0.1 ~iO amp. max. Operating Temperature: 320 to 1200 F (00 to 490 C) Relative Humidity: 0 to 93%, non-condensing at 900 F (320 C) SLC 40 Ohms maximum line impedance.- 0.5 uf maximum line capacitance. ILi-S-E 3 ILI-S-E3 The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 Series 1M control panel with two (2), addi- tional signaling line circuits. The layout is similar to the ILI- MB-E3 excepta number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The ILI-S-E3 provides two (2), signaling line circuits and terminals for the connections to up to 159 detectors and 159 modules per SLC in Velociti mode. In clip mode, each SLC supports 99 detectors and 98 modules. Ordering Information Model Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 Series 1M cabinets: . Cabinet Band 0, backbox. . Cabinet C, INX-E3 sub-assembly plate. . Cabinet C, INCC-E3 sub-assembly plate. For instructions on installing the ILI-MB-E3 or ILI-S-E3, refer to the E3 Series 1M Expandable Emergency Evacua- tion Installation/Operating Manual, Part Number: 9000- 0574, the ILI-MB-E3 Installation Instructions, Part Number: 9000-0579, or the ILI-S-E3 Installation Instructions, Part Number: 9000-0569. ( 13AMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 \ 9000-0605 Rev. E page 2 of 2 VI/WW.gamewell-fci.com Gamewell ..-::'71 FIRE CONTROL ~ INSTRUMENTS DACT-E3 by Honeywell Description The Digital Alarm Communicator Transmitter (DACT-E3) is an optional component of the E3 Series 1M Expandable Emergency Evacuation System. The DACT-E3 sends digi- tal signals over the telephone network to a central station. This module can be located in the main cabinet or remotely located via a local RS-48S serial interface. Digital Alarm Communicator Transmitter . 3+1 2300 Hz . 4+21400 Hz . 4+2 2300 Hz ,..U'~"' ~,~ ~ ~~- - -. ~;:::::: ;,:~~~.. -~~~Il:~l ....'~'"' - . _ "'l(!I._"'" - . -~ -~ ...... if'~ 1~ ....__ ' i- .~~:t The DACT-E:~ is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: . SIA DC8 . SIA DCS20 Ademco Contact ID 3+1 1400 Hz '- In addition to the DACT-E3 being compatible with digital signaling formats, the DACT-E3 features numerous for- mats for communication to a central station. As a digital communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Equivalence. , "!il DACT-E3 Features Installation Instructions . Listed under UL Standard 864, 9th Edition. . Communicates with the E3 ILI-MB-E3 sub-assembly via RS-485. . Communicates in a variety of formats. . T:-ansmits and verifies data to the central station. . Offers pre-programmed dialing to the central station pllone number. . Performs on and off-hook status to the phone lines.' . T-aces proper central station "ACK" and "Kiss-off" tone. . Activates hang-up and release phone lines. The DACT-E3 is adaptable for installation in standard E3 Series 1M system cabinets.. Typically, the DACT-E3 module mounts on standoffs on top of the left side of the ILI-MB-E3 module. Either unit can be easily connected to the backbox or sub-assembly plate depending on the cabinet module. Note: For instructions on in:5talling the DACT-E3, refer to the E3 Series 1M Expandable Emergency Evacuation Instal- lation/Operating Manual, Part Number: 9020-0574 or the DACT-E3 Installation Instructions Part Number:9000- 0580.. Specif:ications Ordering Information Operating Voltage: 24 VDC (from PM-9 power supply) Operating Current: 0.018 amp Alarm Current: 0.018 amp Operating Temperature: 320 to 1200 F (0 to 490 C) Relative I-Iumidity: 0 to 93%, non-condensing at 900 F (320 C) E3 Series"" and NetSOLO"" are trademarks of Honeywell Intemationallnc. Model DACT-E3 Description Digital alarm communicator transmitter An ISO 9000-2000 Company I ~~~~I ] 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 I Speclflcaoons are for information only, are not intended for Installation pUrposes, ~d are subJl!ct to change without notice. No responsibility is assumed by Gamewel~FCI for their use. "', (" @2006 Honelwelllnlemationallnc. All rights reserved. www.gamewell-fci.com 9020-0610 Rev. E page 1 of 1 SIGNALING @ <3>MEA:.,' ~ Ckyof LISTED ......OVI!D Approved " Appro."" Ottnvor 51869 3025415 231..o6-E 7165-06,..:261 g::: ~ Approved 7165-0694:269 HIgh RIae I . _ Gamewell EI.-:'"':7I ARE CONTROL . L&.:U INSTRUMENTS PIN- by Honeywell Description PM-9 Power Supply The PM-9 is a switching power supply that provides 9 amperes of filtered and regulated 24 VDC (nominal). It has an intemal battery charging circuit capable of maintaining up to fifty-five (55), A1H batteries. This module is designed for use with the Gamewell-FCI distributed audio networks. The PM-9 Power Supply is a component of NetSOLO@ and E3 Seriesl!!l fire alarm and voice evacuation systems. It . provides power to the INX Transponder assembly and all E3 Series components. Installation Typically, the PM-9 Module can be mounted in the follow- ing E3 Series cabinets: . Cabinet Band D, backbox. . Cabinet C, INX-E3 sub-assembly plate. . Cabinet C, INCC-E3 sub-assembly plate. PM-9 Features For instructions on installing the PM-9, refer to the E3 Series@ Expandable Emergency Evacuation Installation! Operating Manual, Part Number: 9020-0574 or the PM-9 Installation Instructions, Part Number: 9000-0548. Listed under UL Standard 864, 9th Edition 9 ampere, filtered, regulated power supply Specifications Energy and space saving switching technology Input Voltage: 120 VAC 60 Hz @ 3.5 A. max. Output Voltage: 24 VDC (nominal) FWR Output Current: 9 amperes Alann Current: 0.050 amp. Operating Temperature: 320 to 1200 F (00 to 490 C) Relative Humidity: 0 to 93% (non-condensing) at 900 F (320 C) Dimensions: 101/2" W x 5" H x 2" D (27 x 13 x 5 em) Integral battery charger capable of recharging Lip to fifty-five (55), AH batteries (Batteries not furnished) Ordering Information. Model PM-9 Description Power supply An ISO 9000-2000 Company E3 Seriesl!!l and NetSOLOI!!l are registered trademar1ls ofHoneywelllntematiJnailnc, SlGNAI.JNG aty of (0-'\ ~ Chk.ogn :Y ~ .."..,.... Cityof USlBJ APPRC'AD Oass 1 DElWBt 51.. 301U18 n:~ Class 2 ApJ:m\l~d ..... RIse (' .. --'-~---~'-'---.l GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161. Fax: (203) 484-7118 Specifications are for information only, am not intended for installation purposes, and are subject to change without notice. No I~ponsibility is assumed by Gamewel~GI for their use, @2007 by Honeywell Intematlonallnc. 1\1I rtghts reselVed. www.gamewell-fci.com 9020-0555 Rev. g page 1 of 1 ~Gamewell r::n ARE CONTROL ~ INSTRUMENTS by Honeywell 1100 Series lCD-1100 Description Remote Serial LCD Display The LCD-7.t 00 remote serial display provides superior flex- ibility to the 7100 or E3 Series@ installations. It features an 80-charact€,r display which duplicates all the information on the main display with the exception of menus. LCD-71 00 The LCD-71 00 contains the following function keys: . Alarm Acknowledge . System Reset/Lamp Test . TroubleAcknowledge . System Drill Test . Signal Silence A keylock must be placed in the "ON" position to enable the function keys with the exception of the "Trouble Acknowl- edge" key which is used to silence the trouble sounder on the LCD-710Q, FC!cltures LEDs on the LCD-7100 am: . Alarm . Supervisory . System Trouble . Power Fault . Listed under UL Standard 864, 9th Edition . System Silenced . NAC #1 Silenced . NAC #2 Silenced . 80-character alphanumeric LCD display . Full complement of function keys and LEDs Installation . Remote location up to 3,000 feet (914.4 m) away from the control panel The LCD-7100 can be surface or flush-mounted on a stan- dard four-gang electrical box and installed up to 3,000 feet (914.4 m) away from the main control. The 7100 or E3 Series@ control panels can accommodate up to five (5), remote LCD-71 00 annunciators. . 7100 and E3 Series@ will accommodate up to five (5), annunciators . Surface or flush-mount on a standard four-gang, elt~ctrical box Specifications . Compact, attractive appearance Operating Voltage: Supervisory Current: Alarm Current: Absolute Maximum Operating Temperature: 32' to 1200 F (00 to 490 C) Relative Humidity: 0 to 93% max., non-condensing at 900 F (320 C) 81/4" Lx 4 1/2" H x 1 7/8" 0 (21 x 11 x 4.5 em) 24 VDC (nominal) .012 amp. ,023 amp, Ordering Information Meldl!1 LCD-7100 Description Remote Serial LCD Display Dimensiorus: AnISO~2000~y E3 Sanes@ is a registered trademark of Honeywell international Inc. :;jGNALJNG ~y <8> LISTED """"""-'ED S1 B69 3OO6S7B MEA -.... 25S-ll2-E 7300{JE&4:231 Oty of Chi<llgO Aj:1pnwed Class 1 ClllliS2 High Rise ctv of DENVER Appo\ied [' GAMEWELL-FCI \ 12 Clinlonville Road, Northford, CT 06472-1610 USA' Tel: (203) 484-7161 . Fax: (203) 484-71181 I Specfficalions are for informalion only, are not intended for Installalion purposes, and are subject to c~ange wi/haul nolice. No responsibility is assumed by Gamewell-FCI for tIleir use. @2007 by Hon"'{Nell International Inc. All rights reserved. www.gamewell-fcl.com 9020-0486 Rev. h 1 page 1 of 1 ,) IRI 8 FIRE CONTROL INSTRUMENTS by Honeywell MS-lIF, MS-l lId MS-11 Description The FCI MS-7 Style manual fire alarm stations are available in a wide variety of configurations. They meet the requirement of the Americans with Disabili- ties Act (ADA) of a 5-lb. maximum pull force to acti- vate, Operating instructions are molded into the handle along with Braill,e text. All stations have a key lock/reset which is keyed alike with FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addrl~ssable Station The MS-7AF Velociti™ Series addressable station is a double action station designed for installation in the signaling line circuit of FCI analog addressable control pcmels. Activation of the station causes its assigned address to r,egister at the control panel. The door contains an LED which flashes green in normal condition and lights steadily red when the station has been activated: The station features screw terminals. The Velociti™ Series stations use a communication protocol that substantially increases the speed of communication between the sensors and certain FCI analog addressable tire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times gn:ater than earlier designs. MS-7A Addressable Station The MS-7A Addressable Station is a double action station designed for installation in the signaling line circuit of any FCI analog addressable control panel. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes red in nor- mal condition and lights steadily when the station has been activated. Thl3 station features screw ter- minals. Velociti'" is a Irademark of Fire Control Instruments. Non-Coded, Manual Fire Alarm Stations /~'-' ",; '-.'. ~*fu~~~~~~-::~.~~_~.~ ,pO" MS-? Features · Addressable stations compatible with all FCI analog addressable fire alarm controls. · Conventional stations suitable for use with any UL Listed control panel. · Both single and double action stations available. · Tumbler lock for test and reset keyed alike with FGI controls. · Surface or semi-flush mounting. · Shock and vibration resistant · Stations (MS-7LOB) Listed for outdoor applications. · Meets ADA pull force requirements. Only the red LED ~ operative in panels that do not operate in VelocitiT mode. An ISO 9001-2000 Company SIGNALING @<3> MEA LISTED APPROVEO Approved 52465 3023594 67-02.E Vol.VIII 07150-0694:261 GAMEWELl-FCI 12 Clintonville Road, Northford, CT 064i'2 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change v~thout notice, No responsibility is assumed by Gamewel~FCI tor their use. @2006Gamewell-f:Ci. All rtghts reserveo. www.gamewell-fci.c:om 9020-0616 Rev. B page 1 of 2 \, / MS-7 Double Action Station The MS-? double action station is' used with COrl- ventional fire alarm control panels. It features a set of single pole contacts and screw terminals for con- nection to an initiating circuit. Ordering Information Model MS-? MS-7S Single Action Station The MS-?S single action station is used with con- ventional fire alarm control panels. It features a set of single pole contacts and wire leads for connec- tion to an initiating circuit. Description Double action station. MS-7AF** Velociti™ addressable double action station. Single action station, wire leads. Double action station, English and Spanish instllJctfons. MS-?LOB Double action station, outdoor use. (Must use S8-1I0 - Indoor/outdoor use backbox). S8-1/0 Indoor/outdoor use backbackbox. S8-10 Surface backbox. 8G-TR Trim ring for semi-flush mount. **For use with FC! analog addressable control panels only. MS-7S MS-?SP MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-? station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-?L08 station must be mounted on a Model S8-1I0 backbox, In retrofit applications, tile station is UL Listed for use with the WP-10 back- box. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-? interior stations may be surface mounted (use backbox S8-1I0) or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (8G-TR) may also be used for semi-flush mounting. Specifications Dimensions: Lexan~ 0.25 amp @ 30 VACNDC (resistive) 55/8"Hx41/4"Wx11/4"D (14 x 10.1 x 3.2 em) Material: Contact Ratings: Operating Temperature (MS-7AF): Relative Humidity (MS-7AF): Alarm Current: 32" to 120" F (0" to 49" C) 10 to 93% (non-condensin~l) .0030 amp. 0,007 for LED Supervisory Current (MS-7AF): 300 IJA LEXANlil is a registered trademark of GE Plastics, a subsidiary of General Electric Company. -----'_._----~------_._--~-~---_._~ --'-~~----~--_.~ GAMEWELL-FCI 12 Clintonville Road, Northford, CT 013472 - Tel: (203) 484-7'161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0616 Rev. E: page 2 of 2 ~---~-~-_._-~--~---_._-~~---~._-----~_._----~_._._~..-------.-.~--_._._------------.- Gamewell ..-:'":.'I FIRE CONTROL ILL.:lJ INSTRUMENTS by Honeywell VelociUTM Series ISI-PL2F Ind ISI-PTL2F Description The Gamewell-FCI Velc>citi™ Series, analog addres- sable plug-in smoke sensors with integral communi- cation provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selectiv,e maintenance when the cham- ber contamination n3aches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by .a wide range of combustion sources. Dual electronic thermistors add 1350F (570C) fixed-tem- perature thermal sensing on the ASD-PTl2F model. The Velociti™ Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in thl3 group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to f'ive times greater than earlier designs. Ordering Information Model Descrlptilon ASD-PL2F Analog, addressable photoelectronic smoke sensclr ASD-PTL2F Analog, addressable photoelectronic smoke sensor with tlnermal sensing Analog, Addressable Photoelectronic Smoke Sensor ASD-Pl2F ASD-PTL2F Features · Sleek, low-profile design. · Visual rotary, decimel switch addressing (01-159). · SLilt-in functional test switch activated by an extemal magnet. · Sic:olor LEDs flash green wheneverthe sensor is addressed, and light steady red on alann*. . Optional relay, isolator, or sounder bases. · Low standby current. · Analog addressable communication. · Stmle communication technique with noise immunity. . Optional remote, single-gang LED Indicator (RA400Z). · Suitable for installation in ducts. · CClmpatible with Gam-ewell-FCI analog addressable panels. Nole: *Only the red LED is operative in panels that do not operate in Velociti™ mode. An ISO 9001-2000 Company S1GNALltG @<e>MEA lISTED ......OVED ~owd .... 81913 30m94 2l9-Q2.EVo/.VI 07272-0694:263 GAMEWELL-FCI ] '12 Glintonville Road. Northford, CT 06472-1653 USA. Tel: (203)484-7161' Fax: (203) 484-7118 Specifications are for information only. are not Intended for installaoon purposes. and are slD;ectto change without notice. No responsibilily is assumed by Gamewel~FCI for their use. , @2006 Honeywell Internalional Inc. ,;11 rights reserved. www.gamewell-fcl.cl)m 9020-0617 Rev. E page 1 of 2 Installation Specifications ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenancl3. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. 2.1" (5.1 em) high )[ 4.1" (10.4 em) diameter installed in 8501 base. 6.1" (15.5 em) diameter installed in ADB-FL base. Shipping weight: 5.2 oz. (147 g) Operating temperature: Size: Mount the base on a box which is at least 1.5. (3.8 en) deep. Suitable mounting base boxes include: . 4.0. (10.2 em) square box. · 3.5" (8.9 em) or 4.0. (10.2 em) octagonal box. . Single-gang box (except relay or isolator bases). . With B501 BH or B501 BHT base, use a 4.0. (10,2 em) square box. · With B224RB or B224BI base, use a 3.5" (8.9 em) OGta9- onal box, or a 4.0. (10.2 em) octagonal or square box. UL-Llsted velocity range: ASD-PL2F: :320 F to 1 ~~Oo F (00 C to 490 C) ASD-PTL2F: :320 F to 1000 F (00 C to 380 C) 0-4000 ft./min. (1,219.2 mlmin.), suitable for installation in ducts. Relative humidity: 10-93% (non-condensing) Thermal ratings: Fixed-temperature setpoint 1350 F (570 C) Electrical Specifications NOTE: Because of the inherent supervision providE!d by the SLC. end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Voltage range: Standby current: 15 - 32 volts DC peak (max. avg.): 300 IJA @ 24 VDC (one communication every 5 seconds with LED enabled) Maximum alarm current: 6.5 mA @ 24 VDC (LED) lit). Sensor Spacing Gamewell-FCI recommends spacing sensors in ,:;om- pliance with NFPA 72. In low airflow applications with smooth ceilings, space sensors 30 feet (9.1 m) For specific information regarding sensor spacing, place- ment and special applications, refer to NFPA 72. Bases and Options ADB-FL: B501: B501 BH or B501 BHT: B224RB Relay Base: RA400Z BCK-200 6.1" (15.5 em) diameter 4.1" (10.4 em) diameter Sounder base assembly (B501BHT produces a temporal pattern). Includes B501 base. Screw terminals: .) Up to 14 AWG (2.0 mm-) Relay tYPE!: Foml-C Rating: 2.0A @ 30 VDC resistive; 0.3 A @ 1'10 \/DC inductiVE!; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" x 1.2" (15.7 x 3.0 em) Maximum: 25 devices between isolator bases. Remote a1am1 indicator, LED. Black detectN covers (box of 10). GAMEWEl.L-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA' Tel: (203) 484-7161' Fax: (203) 484-~'118 , 9020-0617 Rev, E page 2 of 2 www.gamewell-fcl.com ----~--~~~-.... \ \ , t _ Gamewell ElI"':'r.'I RRE CONTROL II..i.:U INSTRUM8\ITS lelochi™ Series by Honeywell ITI-l2F,ITI-Rl2F Ind ITD-Hl2F Description Addressable Thermal Sensor The Gamewell-FCI Ve:lociti™ Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point 10 capabil- ity allows Elach sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATO thermal sensors use an innovative thermistor sensing circuit to produce 1350F/570C fixed- temperature (ATO-L2F). The ATO-RL2F provides a combi- nation 15"/minute rate-of-rise with 1350 fixed thermal detection that is included in a low-profile package. The ATO-HL2F provides fixed high-temperature detection at 1900F/880C. These thermal sensors provide cost-effec- tive, addressable property protection in a variety of appli- cations. ATD-l2F The VelocitjTM Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The Velociti™ Series uses a communication pro- tocol that substantially increases the speed of communica- tion between the sensors and Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change. the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. Fecltures Model ATD-L2F ATO-RL2F Description Addressable thermal sensor, fixed, 135" F Addressable thermal sensor, combination fixed,1350 F and 15"/minute rate-of-rise. Addressable thermal sensor, fixed, 190" F · Sh~ek, low-profile design . Visual rotary switch addressing . Built-in functional test switch activated by an external magnet . BiGolor LEOs flash green whenever the sensor is addressed, and light steadily red on alarm* . Optional relay, isolator, or sounder bases . Low standby current · Addressable communication . Stable communication technique with noise immunity · Optional remote, single-gang LED accessory (RA-400Z) · Suitable for installation in ducts Note: 'Only the red LED is operative in panels that do not operate in VelocitjTN mode. Ordering Information ATO-HL2F An ISO 9000-2000 Company SlGNAl.JNG ,- __") @0 MEA .1;; LISTED __ Approved ',_" S2332 30235114 21H2-1! VoI.VI 07270-11iN:2SC Velociti'" is a lrajemark and E3 Series@is a registered traJemar1< at HoneyoM!lI International Inc. UL@ is a registered tralemark of Ul1denNriters Laboratories Inc. GAMEWELL-FCI 12 Glintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 Specifications are for InformaUon only, are not intended for inslallalion purposes, and are subject 1D choo\1Il wilhoUl notice. No responsibility is assumed by G_I~FCI for 1heir use. @2Q07 by Honeywell International Irx:, AU rights reserved. www.gamewell-fci.com 9020-0620 Rev. G2 page 1 of 2 " Installation Electrical Specifications ATD plug-in sensors use a separate base to simplify instal- lation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Voltage Range: Standby Current: max. avg.) Mount the base on a box which is at least 1.5" (3.8 em) deep. Suitable mounting base boxes include: . 4.0" (10.2 em) square box. . 3.5" (8.9 em) or 4.0" (10,2 em) octagonal box. . Single-gang box (except relay or isolator base). . With 85018H or 8501 8HT base, use a 4.0" (10.2 em) square box. . With 8224RB or 822481 base, use a 3.5" (8.9 em) octagonal box, or a 4.0. (10.2 em) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-Iine resistors are not required. Wiring "T- taps" or branches are permitted for Style 4 (Class "B") wir- ing. Specifications Size: Shipping Weight: Operating Temperature: ATD-L2F or ATD-RL2F ATD-HL2 Sensor Spacing: Relative Humidity: ATD-L2F ATD-RL2F ATD-HL2F LED Current (max.) Voltage Range 15 32 volts DC peak 200 mA @ 24 'lDC (without communication); 300 mA @ ,24 'lDC (one communication every 5 seconds with LED enabh~d) 6.5 mA @ ::'4 'loe (LED lit) 1 5 -32 volts DC peak Bases and Options ADB-FLF 6.1" (15.5 em) diameter standard base B501 4.1" (10.4 em) diameter flange less base B501 BH or B501BHT Sounder base assembly (B501BHT produces a Temporal Pattern). Includes B501 base. B224RB Relay Base 2.1" (5.3 em) high x 4.1" (10.4 an) diameter installed in 8501 base, 6.1" (15.5 em) diameter installeld in AD8-FLF base 4.8 oz. (137 g) B224RB Relay Base Dimensions: 8224BI Isolator Base Dimensions: Up to 14 AWG (2.0 mm2) Relay type: Form-e Rating: 2.0A @ :30 VDe resistive; 0.3 A @ 110 VDe inductive; 1.0 A @ 30 'IDe inductive. 6.2": (15.7 eml x 1.2" (3.0 em) 6.2" (15.7 em) x 1.2" (3.0 em) Maximum 25 devices between isolator bases Remote alarm indicator. LED Black detector covers (box of 10) / l 'GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA. Tel: (203) 484-7161 . Fax: (203) 484-7118 I ~020-0620 Rev. C1 page 2 of 2 IIVW1N.gamewell-fci.com -40 F to 1000 F (-200 e to 380C) -40 F to 1500F (-20 C to 660C) UL approved for 50 fl. (15.2 m) center to center FM approved for 25 x 25 fl. (7.6 x7.6 m) spacing 10 - 93% (non-condensing) Fixed-temperature setpoint 1350F (570C) Combination 1350 F fixed temperature and 150 (8.30c) per minute rate-of-riseo Fixed-temperature setpoint 1900F (880C) RA-400Z BCK-200 -~----~~._---~-_.__._-~----..... '1 ! I 8 I!I~~ IiiiI ~ INSTRUMENTS by Honeywell SpectrAlert@ Advance Description ( GAMEWELL-FCI ------I I 12 Clintonville Road, Northford, CT 06472-1653 USA. Tel. (203) 484-7161 . Fax: (203) 484-7118 i Specifications are for informabon I)nly, are not intended for installation purposes, md are subject to c~all!le whllout notice. No responsibility is assumed by Gamewel~FCI for their use. ~ @2006 Honeywell Intemabonallnc. :\11 rights reserved. . WWW.gamewell-fcl.com CS-2539 Rev. A page 1 of 4 ./ SpectrAlert@ Advance selectable-output horns, strobes and horn/strobes are rich with features guaranteed to decrease installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installation of individual devices, and eleven (11), field- selectable candela settings for wall, ceiling strobes and horn/strobes. More specifically, whem installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon, or double-gang junction box. The two- wire mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the producfs tabs in the mount- ing plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's termi- nals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAI'ert Advance products offer the following options: . 12 or 24 volts. . At 24 volts, 15, 15/75,30,75,95,110, 115, 135, 150, 177, or 185 candela bll way of rear-mounted slide switch and front viewing window. . Horn tones and volume by way of rotary switch. The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- wire and four-wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor out- door products are rated between -40oF and 151 OF (-40oC and 660C) in wet or dry applications. Sync. Circuit'" is a trademark, and SpectrAI8/t@and System Sensor@areregistered trade- marks of Honeywell Inlemational Inc. @:W06 by ADT. All rights reserved. Unauthorized use of this documenl is strictly prohibited. Selectable Output Notification Appliances 7087ph02.jpg 7087ph03.jpg Fecltures . Plug-in design. . S~lme mounting plate for wall- and ceiling-mount units. . Shorting spring on mounting plate for continuity check before installation. . Captive mounting screw. . Tamper-resistance capability. . Fil~ld-selectable candela settings on wall or ceiling units: 15,15/75,30,75,95,110,115,135,150,177,185. . Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela. . Outdoor wall and ceiling products. . Outdoor products rated from -40oF and 1510F (-400C and 660C). . Minimal intrusion into the backbox. . Horn rated at 88+ dbA at 16 volts. . Rotary switch for tone selection. . Three horn volume settings. . Eh~ctrically compatible with SpectrAlert@ products. An ISO 9000-2000 Company iij:\G . \!!:J MEA LISTED Approved 54011 452-45-E 7125-1653:1&& Models available: Indoor wall-mount: horn, strobe, 2-wire hornJstrobl~, 4-wire horn/strobe. Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. ities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-TE,mporal (continuous) pat- tern. These options are set by a multiple position switch. On four-wire products, the strobB shall be powered inde- pendently of the sounder. The horn on horn/strobe models shall operate on a coded or non..coded power supply. Engineering Specifications Outdoor Products SpectrAlert Advance outdoor horns, &trobes and horn! strobes shall be listed for outdoor use by UL and shall operate between -40oF and '1510F (-40oC and 660C). The products shall be listed for use with a System Sensor out- door/weatherproof backbox with half-inci1 and three- fourths-inch conduit entries. SpectrAlert Advance hOrnS, strobes, and horn/strobel; shall mount on a standard 4.0" x4.0" x 1.5" (10.16 x 10.16 x 3,81 em) backbox, 4.0" (10.16 em) octagonal backbox, or a double- gang backbox. Two-wire products shall also mount on a single-gang 2.0" x 4.0" x 1.875" (5.08 x 10,16 x 4.763 em) back- box. A universal mounting plate shall be used for mO'Jnting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate, Also, SpectrAlert Advance products, when used with the Sync.Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volls; 24- volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance prod- ucts shall operate between 320F and 1200F (OOC and 490C) from a regulated DC, or full-wave-rectified, unfiltered power supply. Strobes and horn/strobes shall have field-s,e1ed- able candela settings including 15, 15175,30,75,95, 110, 115,135,150,177,185. Synchronization Module The module shall be a System Sensor S:fnc.Circuit Listed to UL STD 464 and shall be approved for fire protective service. The modul,e shall synchronize Spec- trAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 em) backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) cir- cuit. The module shall synchronize multiple zones. Daisy- chaining two or more synchronization modules together will synchronize all the zones the modull~S control. The module shall not operate on a coded power supply. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model Listed to UL STD 1971 and shall he approved for fire protective service. The strobe shall he wired as a primary-signaling notification appliancEl and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 H;~ over the strobe's entire operating voltage range. The Strobi3 light shall consist of a xenon flash tube and associated lens! reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAIElrt Advance Model Listed to UL Standards 1971 and 464 and shall be approved for fire protective serviCE'. The horn/strobe shall be wired as a primary-signaling notifica- tion appliance and comply with the Americans with Disabil- /- ( ------ I GAMEWELL-FCI 12 Clinlonville Road, Northford, CT 06472-1653 USA' Tel: (203) 484-7161 . Fax: (203) 484-;'118 CS-2539 Rev. A page 2 of4 \'IfWVIr.gamewell-fci.com , '-, Operating Specifications Standard operating temperature: 32. F to 120. F (0. C to 49. C) K Series operating temperature: -40. F and 1510 F (.40' C and 660 C) Humidity range: 10% to 93% non-condensing (indoor products). Strobe flash rate: 1 flash per second. Nominal voltage: regulated 12 VDC/FWR or regu- lated 24 VDC.FWR. Note: Full Wave Recitified (FWR) voltage is a non-regulated, time- varying power source that is used on some power supply and panel outputs. B V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). ~~ote: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15/75 cd. Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm2). Ceiling-mount dimensions (including lens): Operating voltage range: Wall-mount dimensions (including lens): Horn dimensions: HClm Current Draw, Ul. Maximum (mA RMS) SClund 8-17.5V 16 - 33 V Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 - :!!,:~pl)ral Medium 44 49 58 69 Temporal Low 38 44 44 48 ~. Non-t.amporal High 57 56 69 75 ~. Non-t,emporal Medium 42 50 60 69 ~. Non-temporal Low 41 44 50 50 ~- 75 Coded High 57 55 69 ~. Coded Medium 44 51 56 69 ~. Code:! Low 40 46 52 50 H()m and Horn/Strobe Rotary Switch Setting) Se 6.8" diameter x 2.5" deep (17J diameter x 6.4 deep em) ~tti ng Repetition Rate dB Level 1 Temporal Hem High 2 Temporal horn Medium 3 Temporal horn Low 4 Nonnal horn Low 5 Nonnal horn Medium 6 Nonnal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low 1:: Settings 7, 8 and 9 are not available on 2-wire /strobe *1'101 horn S.6" H x 4.7" W x 2.5" D (14.2 H x 11.9 W x 6.4 D em) 5.6" H x 4.7" W x 1.3" D (14.2 H x 11.9 W x 3.3 D em) Horn and Horn/Strobe Output (dBA) Swit P'lsi 1 2 3 4 ch Sound 8 - 17.5 V 16 - 33 V tion Pattern dB DC FWR DC FWR Temporal High 78 78 84 84 Temporal Medium 74 74 80 80 Temporal Low 71 73 76 76 Non-temporal High 82 82 88 88 , Non-temporal Medium 78 78 85 85 Non-temporal Low 75 75 81 81 . Coded High 82 82 88 88 . Coded Medium 78 78 85 85 . Coded Low 75 75 81 81 TE: Settings 7,8, and 9 are not available on 2-wire 'strobe. Strobe Current Draw, UL Maximum (mA I~MS) 8 - 17.5 V 16 - 33 V Candela DC FWR DC FWR - 1-- 15 123 128 66 71 15/75 142 148 77 81 Standard 30 NA NA 94 96 Candela 75 NA NA 158 153 Range 95 NA NA 181 176 110 NA NA 202 195 1-- _. NA 115 NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 ~ -- 185 NA NA 286 258 - ~. r------ '----------, 5 E 7 8 9 *NO ht)m GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA' Tel (203) 484-7161' Fax: (203) 484-7118 www.gamewell-fci.cclm CS-2539 Rev. A page 3 of4 Two-Wire Horn/Strobe, STANDARD Candela UL Maximum Current Draw (mA RMS) 8 -17. Input, Sound Pattern, dB Level 15 DC Input, Temporal High 137 DC Input, Temporal, Medium 132 DC Input, Temporal, Low 132 DC Input, Non-temporal, High 141 FWR Input, Non-temporal Medium 133 DC Input, Non-temporal, Low 131 FWR Input, Temporal, High 136 FWR Input, Temporal, Medium 129 FWR Input, Temporal, Low 129 FWR Input, Non-temporal, High 142 FWR Input, Non-temporal, Medium 134 FWR Input, Non-temporal, Low 132 Ra nge (15 ., '115 cd), .:--- 16 - 33 V /75 15 15/75 30 75 H5 11101 115 7 7'9 90 107 176 ~~ 212 218 44 69 80 97 157 182__ 201 210 - --.,g8 ~3 66 77 93 154 179 207 --- ;~ 91 100 116 176 201 221 229 -- -- \5 75 85 102 163 187__ 207 216 .~- 68 79 96 156 182 201 210 ~;5 88 97 112 168 190 210 218 ~;2 78 88 103 160 184 202 206 ~;1 76 86 101 160 184 194 201 €i1 103 112 126 181 20~_ 221 229 1i5 ~? 95 110 166 189 208 216 1i4 80 90 105 161 184 202 211 -- '-- 5" 15 14 1 1.1 if 1.1 1.1 1 1 1 1 1 1 Two-Wire Horn/Strobe, HIGH Candela Rang~! (135 . '185 cd), UL Maximum Current Draw (mA RMS - 16 - 33 V DC Input 135 150 177 185 FWR Input 135 DC, Temporal High 245 259 290 297 FWR, Temporal, High 215 DC, Temporal Medium 235 253 288 297 FWR, Temporal, Medium -~ . DC, Temporal Low 232 251 282 292 FWR, Temporal, Low 207 . DC, Non-temporal, High 255 270 303 309 FWR, Non-temporal, High 233 DC, Non-temporal, Medium 242 259 293 299 FWR, Non-temporal, Medium 219 DC, Non-temporal, Low 238 254 291 295 FWR, Non-temporal, Low 214 16 - 33 ,,--- 150 177 185 231 258 265 ~24 250 258 ~21 248 256 248 275 281 232 262 267 229 256 262 ._----~----.... '1 J ( GAMEWELL-FCI \ 12 Clintonville Road, Northford, C" 06472-1653 USA. Tel: (203) 484.7161 . Fax: (203) 484-'7118 CS-2539 Rev. A page 4 of 4 \'Iwvv.gamewell-fci.com Ft. Summary of Selected Devices FCI E3 Series Fire Alarm Control Panel with Broadband _~~~TIf~-'~'iI-S:r,;~_ ~Il ~ .~L,;~~;:, 1f ~i~~ Part Number Qty Standby Primary Alarm Comments Intel. Loa Interface Main Board ILI-MB-E3 1 x 0.08100 = 0.08100 x 0.15000 = 0.15000 LeO Oisotav & Switch Control LCO-E3 1 x 0.02400 - 0.02400 x 0.02800 = 0.02800 Oillital Communicator IDACT-E3 1 x 0.01800 - 0.01800 x 0.01800 - 0.01800 Auxilierv Switch Sub-Assemblv (ASM-16 1 x 0.01100 - 0.01100 x 0.01100 - 0.01100 INX Power Sunnlv Sub-Assemblv (PM-g) 1 x 0.05000 - 0.05000 x 0.05000 = 0.05000 Smoke Detector 9 x 0.00270 = 0.00030 x 0.05850 = 0.00650 Heat Detector 4 x 0.00120 = 0.00030 x 0.02600 - 0.00650 Pull Station 8 x 0.00240 = 0.00030 x 0.00480 = 0.00060 Horn/Strobe 1 x 0,0??oo = 0.0??oo x 2.11200 -2.11200 .. ... . ,. \\ ..;, Total (Amperesl: 0.1903 A 2.4583 A . 120 VAC 0220/240 VAC . . . . . . . . . . ... . ... . .. .. . ,,:,i:,), '" Tmal Current .....t\~::i ".,., Standby 0.190 A , , '" "'..'.....,p:., ;'i",i} Alarm 2.458 A "i,Gi;;!i;,;."i.L 'f.'", '''''''ye<''; 'PiC},;:?," '{:V Device Qty Draw Standby Qty Draw Alarm 1. System Device Intel. l.ooD Interface. Main Board (ILI-Me.E3) 1 x 0.08100 0.08100 1 x 0.15000 0.15000 Intel. loop Interlace SuoolementBoard (IL1-5-E3) 0 x 0.08100 0 x 0.15000 7100 Panel, 2 SlC 0 x 0.06500 0 x 0.08500 7100 Panel 2 SLCwith DACT 0 x 0.08500 0 x 0.10500 2. 103 optIOnal ModUleS lCD Disolay & Switch Control (LCD-E3) 1 x 0,02400 0.02400 1 x 0.02800 0.02800 ARCNET Reoeater (RPT-E3) 0 x 0.01300 0 x 0.01300 Digital Communicator (DACT-E3) 1 x 0.01800 0.01800 1 x 0.01800 0.01800 Optional Remote Serial Annunicator (LCD-71 00) 0 x 0.05000 0 x 0.07500 Network lCD Annunicator (NGA) 0 x 0.2??oo 0 x 0.2??oo Auxiliary Switch Sub-Assembly (ASM-16) 1 x 0.01100 0.01100 1 x 0.01100 0.01100 Kemote LED unver MOdUle 0 x 0.01100 0 x 0.01100 3. 7100 Optional Modules Printer Transient Module (PTRMl 0 x 0.02000 0 x 0.02000 Remote lED Driver Module (lDM-71ool 0 x 0.03500 0 x 0.2??oo Class A Option Module (CAOMl 0 x 0.00100 0 x 0.00100 IMunlClpall.lrcuil DDtlon MOdule tMl..VMJ u x 0.00100 0 X 0.00100 14. INI-VGC Command Center Intel. Network Command Center (INI-VGC) 0 x 0.15000 0 x 0.15000 Addressable Switch Sub-assembly (ASM-16) 0 x 0.01100 0 x 0.01100 Voice Paging Microphone (Microphone) 0 x 0.00100 0 x 0.00100 Firefiahter's Teleohone (Handsetl 0 x 0.02000 0 x 0.02000 I_TFI \ U " ooo?oo n " 0008..',0 5. INI-VGX Voice Gatewav Intel. Network Voice Gatewav (INI-VGXl 0 x 0.15000 0 x 0.15000 INX Power Suoolv Sub-Assemblv (PM-9) 1 x 0.05000 0.05000 1 x 0.05000 0.05000 Amplifier Sub-assemblv. 50 watt (AM-50) 0 x 0.08600 0 x 2.20600 Addressable Outout Module-Sianal (AOM-2SFl 0 x 0.00200 0 x 0.00650 Addressable Outout Module-Telephone (AOM-TEL) 0 x 0.00200 0 x 0.00650 Addressable Outout Module-Audio (AOM-MUXl 0 x 0.00200 0 x 0.00650 6. INI-VGE Command Center Voice Gatewav Intel. Network Command Voice Gateway (INI-VGE) 0 x 0.15000 0 x 0.15000 Addressable Switch Sub-assembly (ASM-16) 0 x 0.01100 0 x 0.01100 Voice Pagina Microphone (Microohone) 0 x 0.00100 0 x 0.00100 Firefighter's Telephone (Handset) 0 x 0.02000 0 x 0.02000 Addressable Outout Module-Sianal (AOM-2SF) 0 x 0.00200 0 x 0.00650 Addressable Output Module-Telephone (AOM-TEL) 0 x 0.00200 0 x 0.00650 Addressable Outout Module-Audio (AOM-MUX) 0 x 0.00200 0 x 0.00650 7. Smoke OetectorslModules Smoke Detector 9 x 0.00030 0.00270 9 x 0.00650 0.05850 Heat Detector 4 x 0.00030 0.00120 4 x 0.00650 0.02600 Pull Station 8 x 0.00030 0.00240 8 x 0.00060 0.0048 Smoke Detector/Module 4 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 5 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 6 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 7 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 8 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 9 0 x 0.0??oo 0 x 0.0??oo Smoke Detector/Module 10 0 x 0.0??oo 0 x 0.0??oo 8. Signal Load Hom/Strobe 1 x 0.0??oo 0.00000 1 x 2.11200 2.11200 Bell. homo or strobe 2 0 x 0.0??oo 0 x 0.0??oo Bell. horn. or strobe 3 0 x 0.0??oo 0 x 0.0??oo Bell. horn. or strobe 4 o x 0.0??oo o x di ' ,',; '... ) ,,/{/.;'. . " ,', ',' "l~'~~i1~~""'" "I 2.458 ,:..;,,",.<',>>/, .",.' ',' .; >,{},..." I.,.,..,.,;,'., Ft. ' '-'V',II'" fl J'\' . r;, If" ~ i 1 J . 1 , 4.00 I Amps @ 120 VAC Check AC Branch Current Requirements Current required by source to power the fire alarm system. Secondary Load Requirements I 8.43 I Amp Hours Total Secondary Load from the calculation table below. Check I . Secondary Standby Load x Reauired StandbY Time 0.190 A 24 hours I 4.57 Secondary Alarm Load Reauired Alarm Time (hours) 2.458 A x 1.000 hours 2.46 Total Secondarv Load 7.03 Derating factor x 1.20 Secondary Load Requirements 8A3 AH 17.00 I Amp Hours Check Battery Selection Select batteries from the list below. 117 AH Battery (12 volt) Battery Distribution Chart Shows amp-hour distribution of your selections. i I1J Spare Battery Capacity [J secondary Standby Load . Secondary Alarm Load Spare Battery Capacity I~F~~I::~ Seconda~l~oad .2.95 ---~-:- ATTIC 1-011 1-012 1-013 @ Down To 1 st Floor <( 0 CD i= ~ W cr::: :::) w 0 ~ 0:::: ....-J U ~ lL. (f) W". r ~ (f) ~ (f) -+=- ~ ~ = ~ Or::: I :J l.O >= CL 0 ~ N :r: r L{) Cl.. w N STORAGE UP To AITIC OFFICE 1-010 TORAGE OFFICE ELECTRIC ROOM STAGE KITCHEN 1-005 --@--- 1-008 z o f= 0... 0::: () (j) W o I- () W -, o 0::: 0... FIRE ALARM WIRE LEGEND FIRE ALARM SYMBOLS A = 16/2 FPLP NON-SHIELDED (SLC LOOP BLUE) 8 16/2 FPLP NON-SHIELDED (AUX POWER RED) C = 12/2 FPLP NON-SHIELDED (NAC CKT YELLOW) \FACP!- IANN 1- IEXP 1- ISCE ]- []] m [@ IT] IT]wp H8 @ @)M- @) @)1 GAMEWELL-FCI E3 MAIN CONTROL PANEL GAMEWELL-FCI 7100 REMOTE ANNUNICATOR DINING HALL GAMEWELL-FCI FIRE FORCE 8 CIRCUIT EXPANDER co o "- <J) "- U'l GAMEWELL-FCI AOM-2SF SIGNAL CONTROL MODULE 2 w r- (f) >- (f) GAMEWELL-FCI SR MULTI cd STROBE ONLY DANCE HALL 1 A-004 cmJ 75cd ~ 1-006 - GAMEWELL-FCI MS-7AF ADDRESSABLE MANUAL STATION GAMEWELL-FCI ADPF DUCT DETECTOR GAMEWELL-FCI P2R HORN/STROBE MULTI cd 2 0::: <! ~ <{ GAMEWELL-FCI P2RK WEATHERPROOF HORN/STROBE MULTI cd GAMEWELL-FCI MHR MINI HORN z o f= 0... 0::: () (j) W o o z ~ 0::: o GAMEWELL-FCI ATD-L2F HEAT DETECTOR GAMEWELL-FCI MCS-ACCLlMATE2F PHOTO SMOKE/HEAT DETECTOR W/6" STANDARD BASE GAMEWELL-FCI ASD-PL2F PHOTO ELECTRIC SMOKE DETECTOR W/6" STANDARD BASE GAMEWELL-FCI ASD-PL2F PHOTO ELECTRIC SMOKE DETECTOR W/6" B501BHT SOUNDER BASE END OF liNE RESISTOR W 0::: ~ lL. WOMEN'S RESTROOM MEN'S RESTROOM j\PPl~ ()V E1J (1\ Fire ~t~r~'hal of Zephirhills ,~i7ia;y [B] AIR PRODUCTS CONTROL MR 101 C RELAY [0 GAMEWELL-FCI AMM-2F MONITOR MODULE !QB MAGNETIC DOOR HOLDER ~ GAMEWELL-FCI AOM-2RF ADDRESSABLE CONTROL RELAY @ TAMPER SWITCH BY OTHERS ~ FLOW SWITCH BY OTHERS ...J ~ ~ ~~ ~ ~ ~~ ~ ~~Kl" Z 1.1 ~ ~ .. \ ~ ~ ~ ~~ ~~~M~ ~ ~'" ~ .. ~ y Uw.l ~ 161 ~ D. ~ ~ ~ I- :z: o u Vl Vl oU'l L.U N N U'l e OU'lCO <J) r-- <C n:: t<) 0 -t .- t<) <J) 00 \.. I ;;8 ~C;:N o-t -O.U'l O:::l III ~ I LL.. ....J J:_N W"#:: Ol()~ "l!o<( ... W I o ~~~ c;: t<) Cl u..: 0.. U 4: u.. NOTES: All Visual Signal Device Condello Ratings (cd) indicated next to Device, Verify with contract drawings for exact device location and mounting height. CARD ROOM E o u o o L: o >. @ III E \.. o '0 III (l) III 1-003 '6 ::E I w ~ '"'0