Loading...
HomeMy WebLinkAbout08-7852 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 BUILDING PERMIT 7852 Permit Nu!"'ber: .7852 Permit Type: COMMERCIAL Class of Work: NEW CONST/COMM Proposed Use: NOT APPLICABLE Square Feet: Est. Value: Improv. Cost: Date Issued: Total Fees: Amount Paid: Date Paid: Work Desc: Address: 6901 GALL BLVD ZEPHYRHILLS, FL. Township: Range: Book: Lot(s): Block: Section: Subdivision: CITY OF ZEPHYRHILLS Parcel Number: 03-26-21-0010-01600-0021 749,814.00 5/14/2008 28,303.42 28,303.42 5/14/2008 Phone: NEW CONSTRUCTION OF NAPA AUTO sa FT 7800 Name: GENUINE PARTS COMPANY Address: 2999 CIRCLE 75 PKWY ATLANTA GA 30339 NN MARTIN ELECTRIC LEYVA PLUMBING SERVICES INC COMMERICAL AIR AND APPLIANCE AFFORDABLE ROOFING SYSTEMS INC PLUMBING FEE 327.00 RADON 78.00 IRRIGATION METER 320.00 POLICE IMPACT FEE 1,271.40 TRAFFIC IMPACT FEES 99% COM 16,362.92 SEWER CONNECTION COMMERC 2,822.04 IRRIGATION CONNECTION 266.00 BUILDING F"f;nllf tJ!>- ~oo q - 23-iJ6 FE MECHANICAL FEE WATER METER COMM 1" FIRE PLAN REVIEW FEES FIRE IMPACT FEE TRAFFIC IMPACT FEE 1% WATER CONNECTION COMMERC PUBLIC SAFETY 5% FIRE PLAN REVIEW FEES 228.90 320.00 468.00 1,365.00 165.28 899.96 131.82 468.00 H FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)( c) when extra inspection trips are necessary due to anyone of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." t?<N1 L~ CO>NTRACTOR SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Permit No. 78Sz". Date Permitted ~'IIf-D~ Builder Name/Owner Name (; e~_" '.1.e. U ~I # County Parcel No. 03 -26-2/- Dot 0" ()/ (;;(){)- 00 ~ I subDiv: ~ 90 I G~II 6/ KD If -......., ~p-t'c.A-L ClassificationfType of US!? L..t:I ~,. ........ , PASCO COUNTY, FLORIDA Address/Location TRANSPORTATION IMPACT FEE, Rate: Sq Ft Unit: Exempt 0 Yes 0 No How Determined Impact Fee Amount $ lfet 5]../) , 2/) Zone No. SCHOOL IMPACT FEE Account (056) Single-Family Detached House (057) Mobile Home (058) Other Residential J.:I23) Collection Fee Exempt U Yes 0 No. How Determined TAl: Amount $ 11 PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ t;r Exempt 0 Yes 0 No LIBRARY FEE Land Account How Determined Land Credit Land Total Exempt 0 Yes 0 No How Determined Facility Total Total Amount .Rf , Facility Account Facility Credit RESOURCE FEE TOTAL AMOUNT PreporedBy &,~ Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOl!NTS LISTED HAVE BE:EN pAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY ERU Acknowledgement below does not Imply acceptance of concurrence, but simply receipt of a copy of this form. placing the building permit owner on notice of this assessment and thll conditions of payment for same. RECEIVED BY DATE RECEIPT NO. DATE BY ~1\Jur\jc ~AKI~ CUM~ANY ~ONTACT: FRANK DEL CASALE )A STORE DEVELOPMENT GROU'P ~2 CHASTAIN MEADOWS COURT KENNESAW, GA 30114 (770) 956 2609 ENGINEER: GreenbergFarrow CONTACT: KEVIN PRUEMER FIRST AVENUE SOUTH, STE. 305 ;T. PETERSBURG , FL 33701 (727) 362 0280 TIlis instrument Prepared by and Return to: Mich~~l T. C~;.rp Kennedy Contractors, Inc. 1495 Forest Hill Blvd., Suite A West Palm Beach, FL 33406 1111111111111111111111111111111111111111111111111111111II111 2008071211 NOTICE OF COMMENCEMENT Rcpt: 1180052 Rec: 18.50 DS: 0.00 IT: 0.00 05/12/08 _Dpty Clerk Permit No. ' Tax Folio No: 113 --7~~- 2( - 0010 -O(foOo - 002..0 The undersigned hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 173, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of Property: (legal description of property, and street address if available) 6855 Gall Boulevard, Zephyrhills, Florida (see attached) 2. General Description of improvement: New Construction 3. Owner Information: Genuine Parts Company- Frank Del Casale a. Name and address: 2999 Circle 75 Pkwy., Atlanta, GA 30339, 770-859-2923 b. Interest in property: Fee Simple c. Name and address of fee simple titleholder (if other than Owner): JED PITTMAN, PASCO COUNTY CLERK 05/12/08 03: 14~m 1 if ~ OR BK 7834 PG 817 4. Contractor: Kennedy Contractors, Inc. a. Name and address: 1495 Forest Hill Blvd, Suite A, West Palm Beach, FL 33406 R' b. Phone Number: 561-434-1300 c. Fax Number (optional, if service by fax is acceptable): 5. Surety: N/A a. Name and address: b. Amount of Bond: $ c. Phone Number: d. Fax number (optional, if service by fax is acceptable): 6. Lender: N/ A a. Name and address: b. Phone Number: c. Fax Number (optional, ifservice by fax is acceptable): 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided in section 713.13(l)(a)7., Florida Statutes: a. Name and address: Al Graese 11716 N. Florida Ave., Tampa, FL33612 b. Phone number: 813-935-2742 c. Fax number (optional, ifservice by fax is acceptable): 813-935-8414 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713 .13(l )(b), Florida Statutes: a. Name and address: Sonny Supan 2999 Circle 75 Pkwy., Atlanta, GA 30339 b. Phone number: 770-956-2200 c. Fax number (optional, if service by fax is acceptable): 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified): 7/ Signature of Owner 0 Lt( ~t'6Vv~I"~;a-~. S~ to and subscribed before me by rn..... Ie:' npj G:t.s.q(.p_ who is personally known to me or produced as identification, and who didnc,:t take an Qath' this ,~-+h day of .....:~LL. , w ~ -""'S . ""anae "n;"l(uy ~~~ Printed 1'lame ofNotHry:.' '1" . Comt~'ission No.IEJCpiraticm: 3. / ( r; I...,. Seal: I / Owner's Name: Frank DelCasale for Genuine Parts Company Owner's Address: _2999 Circle 75 Parkway Atlanta, GA 30339 Rebeccn Lock Notary PL!bliC Fulton County, Ge'.Jrgla My Commission Expires f,;~C(l15, 2010 _,J> . .. \ - , 4 1340 . . . ( I . "- EXHIBIT" A" LEGAL 'DESCRIPTION A parcel of land being a portion of Tract 16, ZEPHYRHILLS COLONY COMPANY, as recorded in Plat Book 2, Page 6, Public Records of Pasco County, Florida, also being in a portion of the Northeast y.. of Section 3, Township 26 South, Range 21 East, Pasco County, Florida, being described as follows: ComII;lence at the southeast comer of the Northeast y.. of said Section 3; thence North 00013'18" West, along the east l~e of the Northeast y.. of said Section 3, a distance of 1987.85 feet to the easterly extension of the south line of said Tract 16; thence North 89056'37" West, along said easterly extension, 15.00 feet to the southeast comer of said Tract 16; thence continue North 89056'37" West along the south line of said Tract 16, a distance of63.82 feet to the west line ofa parcel of land described in Official Records Book 6146, Page 1202, public Records of Pasco County, Florida; thence North 00021 '27" East, aiong said west line, 28.00 feet to the Point of Beginning; thence continue North 00021 '27" East along said west line 21.02 feet to a non- tangent curve to the right having a radius 'of 35.00 feet, a central angle of 17" 04' 18", a chord bearing of North 22046'07" East and a chord distance of 10.39 feet; thence along the arc of said curve and said west line, 10.43 feet to the westerly right-of-way line ofD.S. Highway 301 (Gall Boulevard), as shown on Florida Department of Transportation section map 1405-202, Public Records of Pasco County, Florida; thence North 00020'26" East, along said westerly right-of- way line, 71.40 feet to the north line of the south 130.00 feet of said Tract 16; thence North 89056'37" West, along said north line, 351.44 feet; thence South 00003'13" West, 102.00 feet; thence South 89056'37" East, 346.96 feet to the Point of Beginning Containing 35,176 square feet, more or less. [13] User/Genuine Parts Company/1822.88/Deed Page 3 o ::u all ~ N---J Q) W ~oI::lt N " Cl .... Q) .... Q) Fire Chief Keith Williams ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Contractor. }{.il!!l.d 't ('t~ Billing AddreSs: .' Occupancy No.: Plan No.: cfI-(;)~ Business Name: 1J-- Business Address:' biD I b rQ- II Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES Site Plan SPRINKLER SYSTEMS B 0 - 25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 FIRE PUMP o Per Pump FIRE ALARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS B~~ :: Bother $50 KITCHEN EXHAUST o HoodIDucts OTHER 8 LP Installation per tank Fuel Tank Installation (Per Tank) o Natural Gas Installation (Per System) o Spray Booth INSPECTION FEES NlC N/C $100 $250 $500 $100 Annual 1 st Re-inspection 2nd Re-inspection 3rd Re-inspection 4th Re-Inspection (Business closed until violations corrected) SPRINKLER SYSTEMS ~ Hydro Unclergrounds $45 Hydrostatic Test $65 Acceptance Test $45 Hydrant Flow $75 per system per system Billing Phone No.: Billing Fax No.: Contact: PERMIT FEE $50 $50 $50 $50 $50 $50 $50 $50 $100 $500 $25 $100 $50 $50 $25 $50 $50 $100 150 per wall per lank per system Sprinkler standpipes Fire Pump Hoods Fire Alarm LP Gas Natural Gas F~I Tanks- perlank Sparklers Fire Works Camp Fire Controlled Bum HoodIDuct Place of Assembly Fire Protection Flammable Application WiSe Tire storage Generator < KW Generator >30 KW Bic-Hazard WiSe Fumigation Tenting Torch Pot/Applied Haz. Materials FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPLIANCE $150 Annual Annual Annual $100 Annual $50 $50 $100 Annual FALSE ALARM TOTALI $so ~ Tent 1 0'x1 0' or greater Fire Pump Fire Suppression System Acceptance B Exhaust HoodIDuct $30 Re-inspection DBL (other than annual) $50 0 Inspection scheduled DBL and cancelled less than 24 hours B Construction Insp. N/C Emergency Vehicle Ao $50 PLANS TOTAL~ INSPECTION TOTAL~ FIRE ALARM SYSTEM B System Acceptance $50 Recall Acceptance $50 OTHER ~ Fire WalllSmoke Wall LP Gas Natural Gas $15 $25 $25 $50 $50 $50 $50 $15 $45 $30 per lIlnt B PERMIT TOTALc=J ~s-- Comments: GRAND TOTAL S/5l1/d1f .Kerry ~~Alt!-ff -F~ Date: 'ns~ctor: City of Zephyrhi1ls BUILDING PLAN REVIEW COMMENTS Site: ;J A(J l+- S- -'If-oB ~9/)1 GAl! 6ft/V !.f.-UI5/tfY' 77> )I~/0L ContractorlHomeowner: Date Received: Permit Type: Approved wino commenlJ!.t Approved wIthe below conunents: 0 Denied wIthe below conunents: 0 ~.,i ~/]~:?2- fl.MVsn '?Jh ~Jfl ~ 6 f:;. cJ7) IOliht. ~~ -W) This comment sheet shall be kept with the permit and/or plans. f~)'~ll Date Contractor and/or Homeowner (Required when comments are present) Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 May 30, 2008 I have reviewed and approved the plans (mechanical) located at 6901 Gall. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Duct detectors shall be installed to shut down units. Reset switches shall be installed in an accessible location. 2. Ensure fire damper is fire caulked around damper prior to installing sleeve/cover plate. Inspections Required 1. Fire damper verification in electric room 2. Duct detector test. .'-" ~ ~TM ,....., , ' o ,..., ~ i n (i n r" ~ (i PERFORMANCE BUSINESS PRODUCTS. INC. 813-719-6008 FAX 813-719-7919 CITY OF ZEPHYRHILLS ZEPHVRHILLS, FLORIDA WATER ACCT. NO. DATE 5-1'1-0& SERVICE ADDRESS ~~~~':i J<.p fiMdr. &Ac[-~O: Z G MAIUNG /1~~~ t:i.6/VJJ S-rGI4 /;j~~ - Lm _ Y-l 3 3~~ 69/)1 GA-lllfll/j) ~ATER o / .,---...... I SHUT OFF SERVICE TURN ON SERVICE cv tY o SEWER INSTALL METER o GARBAGE ~- READ METER o ~ITY CHECK METER o o OUT CITY -L No. OF UNITS OTHER o .L i r rfj47M /lIte...<k..- I' pu;.,.,f- -#= 7862- - DEPOSIT AMOUNT - AMOUNT LAST BILL _DATE - MISC. CHARGE METER: full irrigation WORK COMPLETED BY & DATE COMPLETED ~ l~ Retain while form in office at all times. Send pink & yellow forms to Water Service Dept. Water Service Dept to sign yellow form & return to office. r r (j n (' n .f'\ (i (i (""l (i ~ INK T... PERFORMANCE BUSINESS PROOUCTS, INC. 813-719-8008 FAX 813-719-7919 CITY OF ZEPHYRHILLS ZEPHYRHILLS, FLORIDA WATER ACCT, NO. DATE ~/1-0 e OWNER! RENTER (Qui MAILING SERVICE ADDRESS SHUT OFF SERVICE o W a;v" c..-wATER TURN ON SERVICE o SEWER INSTALL METER o GARBAGE READ METER o o o tAJ(LJu /Yle-~ I' L/'-M- 7~5Z- pe-rt?? r ..,...-?'" ~N CITY CHECK METER o OUT CITY ~ No. OF UNITS OTHER I -- - DEPOSIT AMOUNT - AMOUNT LAST BILL _DATE - MISC. CHARGE METER: full irrigation WORK COMPLETED BY & DATE COMPLETED Retain white form in office at all times. Send pink & yellow forms to Water Service Dept. Water Service Dept. to sign yellow form & return to office. ORDER TAKEN BY ~ . KENNEDY CONTRACTORS, INC. ~1fl"1}'1f 165~ May J 4. 2008 City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 Gentlemen/Ladi es: Please accept this Jetter as your authorization to allow Ray Lannom to apply for. sign t\lr or pick up any permits. certif1cates of occupancy or certif1cates of completion on behalf of Kennedy Contractors. Inc. Thank you for your assistance. Sincerely ./' ./;.... -",'.'/ , .... ,,/ .-'/' ,,/ '---/ " . l...fIA.....,~-...A,~.....,~-:~ ThomaS'-F.' Ke~. ()ualifier /,' ,."~/,,," "FK'hY State of Florida County of Palm Beach Signed before me this 14th perscnally kno\vn to me. day of Mav. 2008. by Thomas F. Kennedy who is 1 i ,/ ,. ~/~ ,I i -..i/vv'../ i, I.' Ashley N Y\:omans. No/arv .' .: ,.... I ~...... ~jotaly Public.. ""'. """I ! ~"'1: A.Shiey N Yeomans ~ :"'~. My CommISSIOI1 DD492553 .... 0. .:.1' ExptfllS 1112012009 ,. ._.~.~c_,,,,,,-,c-,,,,,,,,,=~,,.=-_~, . (561) 434-1340 (561) 434-130~ FAX 1495 FOREST HILL BOULEVARD' SUiTE A WEST PALM BEACH, FLORIDA 33400 CGCA28023 813-780'{)02D A1B5V f:1' Fax-813-780'{)021 City of Zephyrhills Permit Application Building Department Date Received Owner's Name Owner Phone Number Owner Phone Number I Owner Phone Number I Owner's ~ddress Fee Simple Titleholder Address I N J A ~aJl J30~'t~_~:b~O _ b;~~O:'Il~: (OBTAINED FROM PROPERTY TAX NOTICE) ~ NEWCONSTR D ADD/AL T D SIGN D MOVE D D INSTALL D REPAIR PROPOSED USE D SFR ~ COMM D OTHER I TYPE OF CONSTRUCTION ~ BLOCK D FRAME ~ STEEL D DESCRIPTION OF WORK I New &NS~ li1P~~r+5 ~Ye.. BUILDING SIZE 5.f. sa FOOTAGE Ii. ~ ,Nt:'! HEIGHT llu "8" +0. /.1aSIlq. 1$~52 /lq2- I 1$ 61J lQz.. I 1$ 21, '004 I 1$ 82.. 'L6p I D GAS ~ ROOFING D FINISHED FLOOR ELEVATIONS I e'l. 4'5 I I JOB ADDRESS SUBDIVISION WORK PROPOSED DEMOLISH OTHER I ~ BUILOING VALUATION OF TOTAL CONSTRUCTION r:gj rgj c;gJ ELECTRICAL AMP SERVICE. D I J PROGRESS ENERGY D ~.EC. Ort:..:~ .Ptoa~j (".Q '/ l-r/O" RC~. 17 ..Qfl ~'PLJIJ(,.- \ ') liJ /Jj, N~ 5-12. J. M~ (1'el!!T' (on'Omco.7 .LJ/..f!-I'- . "~~ ..Ph_ ,_ VALUATION OF MECHANICAL INSTALLATION 'Izoo l~ 0 D ~ ~ Cc~/5~.- ~. fA~. SPECIALTY D OTHER - F{rYlI2..h/01 lUVU FLOOD ZONE AREA DYES DNO , _ L ~ \~.5) I ;::.. tQ e.j, s, (/'(\.b ....1kI1:1..J:: . . PLUMBING MECHANICAL BUILDER SIGNATURE Address II13r~J~~jcu'~pY1tt&1or~ 1JG License # k:~ -(~ (" A- 2.<60 Z 3 ~'1rfc;REf:j1fj;iI- ~~I License # I ~C./? 0 lJ /Jh I ')t/1tI 6/"'t~ IIV'} Y/N ELECTRICIAN SIGNATURE Address PLUMBER SIGNATURE Address ...-c.pc-; '125'&/14 I I I I License # ~~ ..~.~ ~ Address 11 OTHER ~ .1~ -(l.J SIGNATURE ~ Address 9~tJ.; MECHANICAL SIGNATURE COMPANY REGISTERED L..!.!..!!...J FEE CURRENT L2:..!.!!....J I ~D I license # COMPANY REGISTERED L..!.!..!!...J FEE CURRENT L2:..!.!!....J License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Sanitary Facilities & 1 dumpster Attach (3) sets of Building Plans; (1) set of Energy Forms. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Sanitary Facilities & 1 dumpster All commercial requirements must meet compliance. Attach (2) sets of Engineered Plans. '-'PROPERTY SURVEY required for all NEW construction. COMMERCIAL SIGN PERMIT Directions: Fill out application compieteiy. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AlC upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades AlC Fences (PloVSurvey/Footage) Driveways-Not over Counter ~ on public roadways..needs ROW NAPA - Gall Blvd - 6901-prmt#7852-Kennedy Contractor Inc SQ. FEET PRICE MAIN OR LIVING: 7,800 $ 96.13 OTHER AREA UNDER ROOF: - $ 96.13 OTHER: - $ - VALUATION $ 749.814.00 FEE SHEET $ 2.180.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 2.283.60 ELECTRICAL: $ 490.50 PLUMBING: $ 327.00 MECHANICAL: $ 228.90 SUB-TOTAL $ 3.330.00 RADON: $ 78.00 TOTAL $ 3,408.00 SEWER: $ 2.822.04 WATER: $ 899.96 IRRIGATION: $ 266.00 TOTAL: $ 3,988.00 WATER METER 1":1 $ IRRIGATION METER 1": $ 320.00 I 320.00 FIRE DEPARTMENT FEES PLANS TOTAL: $ 468.00 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 468.00 PUBLIC SAFETY IMPACT FEES POLICE $ 1.271.40 FIRE $ 1.365.00 5% $ 131.82 TOTAL: $ 2,768.22 Plus Rev Fees & SUB-TOTAL $ 11,272.22 ~IUS25%TIFtoPlckUP Penn It If not paying Total 75% due before @ Premeter Inspection PARK IMPACT FEESI $ l Not Applicable SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - Not Applicable Not Applicable TIF'S: $ 16,528.20 99% $ 16.362.92 1% $ 165.28 25% Total 99% 1% $4,132.05 75% Total $12,396.15 $4.090.73 99% $12.272.18 $41.32 1% $123.97 TOTAL: $ 27,800.42 Revision Fee-Blda $ 35.00 Revlson Fee-F!,e $ 468.00 Total $ 28,303.42 All TIFs must be paid in total before Premeter Inspection pd --k~ / (/1-/ 7 L~ cJL 4t-,. <J f!!{I~ ~- S:-I<f-~ Ma~ 14 08 08:54a Commercial Air 941-746-9812 p. 1 .~.._.._. - / '..... ! 'J ! '/ / ,I I ,. i I , ./ ,. / I :' I / i / _ _a........--.. .._o__..a... 11:J,.7~ ... City ofZephyrhllsPermit AppIicat~ 8U1dIna o.PIIrtMn1 .A:C 155'1/ ~ .. "_13-~1 -~... ",..... ~ct..rp__ OIIMI". AdclNM Owner 1'1I_ NumIIer '. ~",-~""""rl 'OWlI__N_I. 0WMl"11Mm1 ~..81"","lIl"""'dec"Mdrns rn I A : ~ I t;.J11JoW<w,~,"~ ~'5.~3~ ~ =. I- . NYI I . PA~~I ~...1. -2} - /)()/~ - tJ/lll){)' ~ 002.1 , IOlIr__ _l!In'tTAllIIGIlCEl ~ MEWCONSTR B ADDfALT 0 SIGN .0 MOVE D DEMOl/eH o INSTALL REf'A"" PllOII'O!lED use 0 SFR ~ COMM D Oll4l;~ I TYl"Il Of COHllTRUCT101'1 CBI BLOCK D FAAMI< ~ STeL D OTHER I llESCRll'llONOFWORK IN&J ej)N~ ~P.4 ~~t:, .' ........... I ~fj)O s.f. I .........11: 5."l ~ ';"n'~. I8l BUILDING ~ 5 Z , .c\q L I VALUATION OF TOTAL CONS'TRUCTIOll cgJ I!LECTRICAL r 51 lQZ. I _SERVIC& D Ll P~E66ENT D .pllR.!.C. ~ ; o~ ~~ce~')c..Q ~ rr/D", Ot..U __&2.-0tJ PL\JM8INQ I' 211 '5O'-t I MU6'f'~~ CDl"DmCM!':> .JJL/& ~~ d ~ .~._ ~ MECHANICAl I' si. '2.5~ I .VALUATlOH01'MECHANlCALINSTAUATlON \1'lDCl" 0 0 a~F"' D GAs 8 ROOFING 0 Sl'EClAL'rI'D orHER ' ~~;fit tu-,1n-1 "'~. FIN18HEO FLOOR ELWAllONS I AD . .J. II!. '1 FUlCO ZON!! MEA c::Jv&8 CJNo _ I ~ - L"I . I;H~.J . ~e~~l~ I.Ul-'1 ~ ' JDII ADDIl!!SS 81l8DMBION VIIOAK PAOPOlIl!!D Add... -rF.>D I ~i~t~P~~t; tJ,0. LIconM' ~~ L- h7Jl(J Z ~ ~~~dPm~d LicannN I G::I"lob/.J~1 -l<Jb!,Ip /I)tlM6J"'9IP} I Ci:I!tJ 'f&CUIlR!J'!T ""'L:::!IE:I L....U 1 .-.-c;.p(;ILJZ5'~KA 1.-L15.,~,y1/11(;)e/(7/ r1;;: I --t:1ft:f ...._MT E:ttE::J Lbrw. l(il1~7"3(v I UL!LJ f&~ ~ . 1 L_. C=--' I 8U1\.D~ S1GIIAlVRe '- ~I.ECTIllCIAN S1ONA~ . AddNos PLUMIER SlGHATURE ~e MECHaNllOAL B1CNATURI! ~ ~_U'l. ..,t~=TUru:' ~ AddJft8 I ~<g't.i RESlDEN'IIAL COMMIRClAL SIGN PllRNIT ......., (2) Plot "'_: (2) .... oIlluMnQ Plalle; [1 I ul 01 Energy Form. Mnmwn Ion 1101 ~ dI\YI- .......... d.... Roq.,nd -eo c....trucIlon rI8no. 8..,. F....1es & 1 llumllOl" AbCh 131 HlI'atBUIdInII PIonJ; (11.01 Etwft 1'_. . Mir/Ift.... tM(10)WllIIcIIO .,.alI.. subm... dIIe. Reqund -'Ie. C_\II6Ol\ PIIN, Slnury FacIlIIieo & 1 .UlIIpoIW Ad oommlnllol ~_ mull _comlllllne. . ......,..(:l)"..at~P....s. --PR,OPl!RTYSURVEVllqUtodrw01 NiW~1orI. PI.-II_: Fill "'" ._iMCllIIIpleIIly. Owner'~""_OI_-,- "ove, __0.. l'Io\loe of c...._,............... ia Nq11Irea. (AIC u...,.... _r "-I - As-n\ r.or- -ClOt).. 1'_ 01 A........., (!at lt1e 0Wtl4!I') WOUld De li.m.onowllll "~od .... flam - IIUlI1al1zin; -- . OI/IlR TfoIIi COUNn!Jt PEIWm..ca l/'lunl 01 AppI'cltion Ol'lly) . Re""". 8- seNlce Uparodoo Ale Fonoes (PIoVS16WYll'1lO1IllI1 DriWweyHfOl_~1I "" publD_ayLne_ ROWT 100/100 'd llOD-D8L-EIB 'ON XH ~NI01Ing S11IHHAHd32 ,1 NY Z9:90 gOllLODZ/gI/IVW ja~ 14 08 07: 58a Commercial Air 941-746-9812 p.2 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION .. ~1 CONSTRUCTION INDUSTRY LICENSING BOARD .~ ~. 1940 NORTH MONROE STREET fr:ijj...~~. TALLAHASSEE FL 32399-0783 (850) 487-1395 ALLRED, BRETT R COMMERCIAL AIR &: APPLIANCE SVC INC 2418 41ST STREET EAST BRADENTON FL 34208 .~; DE~=;:'~6'BtJsi~s~ tl:~ b 3 \,.~".~7 ,'PROFESSIONAL REGULATION CAC058586 09/13/07 "'0701407,66 CERTIP.~ED AIR CORD CONTR AULREii/" BRETT R :COMMERCIAL AIR & APPLIANCE SVC IN . ..- .' '. H l/ IS, CERTIFIED \lACIer tbe',proviaioo.. of ch.489 I'S. Exp..,.ti.~,,~.t~,AUG31,20.08. . L07Ull00455 DETACH HERE ACt! .~ I ..~ r\ ...", .-. ~ .;> ifL U t") !) .::' ST~TE Of FLORIQA , DEPARTMENT OF,~' BU'SOOS.S:. ANn PROFESSIONAL REGULATION'....' ,I".i.,~" ...:... :: .' CONSTRUCTION', INDUSTRY,LICENSINGB~ARD "SEC:l# :t'01.0 9'13'00:455; "'::':~'A/':'~ . '~""_" ._ ,-,_~, . ',' DATE 09 .13 2007 070140766 CAC058586 The CLASS B AIR CONDITIONING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2008 ALLRED, BRETT R COMMERCIAL AIR &: APPLIANCEL,:s-vc INC 2418 41ST STREET EAST" . , BRADENTON FL 34208 :",~,r.i'" ,'. ," .', - :- .'.. ,-' .- - ..--.. : /,>.~/,~'" DISPLAY AS REQUIRED BY LAW- . ;: ~~"-" ! ",:r':BotLi';:BENSON ., <S.ECRETA'RY .J,i., , , CHARLIE CRIST GOVERNOR t'-~j Ma~ 14 08 07:58a Comm@rcial Air 941-746-9812 p.3 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTR~ LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 (850) 487-1395 -\ COMMERCIAL AIR &: APPLIANCE SERVICE INC 2418 41ST STREET E BRADENTON FL 34208 . .D:i~~ON~~~~~::; F' QB0019207 08/17/070~ci096S17 QUALIFIED BUSINESS ORGANIZATION COMMERCIAL AIR &APPLLANCE SERVIC (NOT A LICENSE_TO PBRFORM WORK. ALLOWS COMPAHY'l"O DO BUSINESS IF IT HAS A LICENSED QUALIFIER.) IS QUALIFIED unur ~be provision. of ch.489 FS. _t...U_ date: AUG 31, 2009 L0701l701457 DETACH HERE Jl ? ':~ /~ Q ~-~ ~ () AC". .~.' ".I' : _..' "_~ ,\.: "".' STATE OF FLORIDA - DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION .. . .. ... _.. _ . CONSTRUCTION INDUSTRY LICENSING BOARD$EQ#L'07c0817014:57 : - LICENSE NBR 08 17 2007 070096517 B0019207 The BUSINESS ORGANIZATION Named. below. IS QUALIFIED . _ _ Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2009 (THIS IS NOT A LICENSE -TO PERFORM WORK. THIS ALLOWS COMPANY TO DO BUSINESS~.;~NL~ IF IT HAS A QUALIFIER.) COMMERCIAL AIR &: APPLIANCE,-SERVICE mc 2418 41ST STREET E ..:-; BRADENTON FL 34208 CHARLIE CRIST GOVERNOR DISPLAY AS REQUIRED BY LAW HOLLY BENSON SECRETARY Ma~ 14 08 07:58a Comm@rcial Air 941-746-9812 p. 1 ~~. D @DiJJ/b iJJDIld ~ 0 J llTK91it1f} M@ -........ '" 2418 41.t Street East Bradenton, Florida 34208 Ph 941-744-1272 Fax 941-746-9812 www.CommerciaIAirService.com Fax Cover Sheet ~-v }", tI To: ~--\~~~ Fax: 1/ '-7$C.-tJ(~/ ~ ".1. /\ J.' .. . ....;, I .~._. /1,: . From:' r.> "loT'! .' ~ ~&-j ELi Date: GJ.;-44y' Phone: Paces: Re: cc: _Urgent _For Review _Please Comment _Please Reply _Please Recycle Comments: .r-' /' '. .< ," ,/ /lV j .e- ,- q C/ /,.1i/1CI I /' ,/l/7 ., c..';tC-' //c.',f~f'I~~ ,f'i: 'J {(lj(C! (/ Iti/tj (YP//r/ tatf/' /;tf/;l~ Vt/;fe",,)C/L/ -It; ~1j tjF1 . . /- , / l I ~ /)~ '''--:'J L /{/ ?P/CVFt/10 c-J j/L.1 i/7// l C? t'~~); fi/'t1? /c..- ;", "1/ ! . , J 1 ' , J,' '.--:- . -1 ..""t! ./ /dA. D )"~ ,.j /:('4,) I r I t;.0 it- L-d From: Kit'"" Ferris At Greene-Haze' & ;>,sso:, FaxlD: Tc:::ty ofZe"hyrhiils Date: 412S12J08 01 :3J PM Page 2 of 2 ACORD~ CERTIFICATE OF LIABILITY INSURANCE DATE rMM'DDIWYYI OP ID KF KENNE-3 04/28/08 THiS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AMEND, EXTEND OR AL TER THE COVEMGE AFFORDED BY THE POLICIES BELOW, PR:'Dl,CER Greene-Hazel & Associates ,Inc. lO~39 Deerwood Park Blvd, #200 Ja~ksonvi~le FL 32256-2873 Phone: 904-398-1234 Fax:904-396-7432 INSURED I ! INSURERS AFFORDING COvERAGE ! NAIC '# ~-~-~~lF;' _. .~.:Ilt.ti.ld :nS1.l.rl,nc$ C~.pU'lY -------~-112.--- r~~'~~fr.:-;;--cNA_~n~~ran_~~compa_nies --=;-02I86~~-' Kennedy Contractors. Inc. At tn: f:I.r. Michael Carp' 1495 Forest Hills BlvQ ste A West Palm Beach FL 33406 ~~:::~~c---___n-'---_---------+------- , --------~-_____-J...-_____...~______ i II\J~J'EF E COVERAGES iH:: ~()L1Cit::::. ()F It j:~,U::A',(:E L: STELl b::LOv'.j r"jA',ic_ BEE ' '::;:;'::;1.;[:..[; TU TH= t' i:'Uf.:ED t'J.L",iJ1~LJ ,..l.,bl)',/t: F')~ I-c. P(_li.; "FlRI0L', ~~L'I_AT=D 1'4(":\1 111-:~:i,.u.f\JDi!'i'_~ Nb' RF.:)I_, REt,.1Ef'r TERM ','R:':::lr":',T!CN OF ;:)..J'!.... C:,,'JT::;A':7r ::IP ('i:HF:R COCUr'Il::;'JT ',,",1,-.., RESPECT T') VI/Hie:!; THI:3 ':EPT'FI,:::j;-'~ r,il._y 8E3:3UEC OR ~1A" PEP-'Ai!.,) THE ~JSUf'\,6N~::-E~.FFOR:'E[,' :;'( THE p")L C'ES :)ESCRIBED l-l=REil< '::"3JE,.'E:r':(.' ,A,L_ Tf-:E TfP",1S E/;CLUSiV<::i.l.f\:D ::::>~"~,;OITlutJ:~ ~:,l= SUCH PCLiCIES .c.',:'l:,R::(.:>C:-;-E. L!~,.1,TS ',:-:HC)-:"m ~J1A( L..l.,L,V'=: ::E.Ef'J h'ECI.i:'EO 8'1 i='t-" 0 l.::t,t;,lt,,:,~, A , ,..----.----.-------..,-----------.-----.- ", r;ps; OF 1'.S'.IR"'t-lCE i _ PO~ICV NUMBER , GEt.ERA~ ~IAB,LiTY 4:0"M=RC'AL "E"EI'".LL,~8UI' I I i '-:L /~ t'rl:; \l;Df: 'X ! -.{Yj j~ r--'''';---' '-....J 06/01/07 -------ro1JCr CffcC, ,VE ~TE (MM/l)Dr(Y) I Cl:1I11642516 I r -~ , , ~~~jL-;;:~E(.ATE Li~'.I;T ,~;~~E::' PE;~ ~~-l ~(J! 1'- l' ~X-" --I oJD?l' I' '.'Y..: :--..." 1 ,...<... , A : ;"UTDMOBlLE U:.BIlI1"\' l~ I X ' Moly PUTC, ~ '. ~.~ ~'~_' ,:"'l':'!'ED~1 n )::; 1 ':;l_H::DUL[:.D ,-,-1,:-1:1:""; ;-----1 , : HiREI- -"_ ~O= I ~ ~~;:v~[[~~~: Damage I CMl>11642516 I I -1- I QARAGE LICo8'LlTY : r---' 1 L----i ;l,J~y AUT(' , I 06/01/07 ! Cl:1I>11S42516 I , 06/01/07 I A A E"CESS;UM8REL~'" lIA81L1TY [~ r):CUR CJ !:L/-Jrv:~ M,.o.DE r=l 'l[[J'XTIE<LC X I REk',TI(N i 0 I - I Cl:1I>f1642516 I 06/01/07 WORKERS COlIIPENSATION AND EMP~OYERS' LIABILITY e A!\jY PRCPRIET:JRlp.c,RT\[RiE:-:.ECUT V[ eFr, :':E';'(.'ME~/,Bt+. Ei_LLJ]E:C', 2083385468 06/01/C7 f Y~'" d"",,::Tit'e ;J;'jer SPEOA_ PFKlVi~I::'f'i'3 091(1\,',' OTHER , I 06/01/07 i B Leased/~ented 12083385437 Scheduled I DESCRlPTIC,N OF OPERATIONS/LOCATIONS I VEHICLES / E(C~"'SIONS ADDED BY ENDORSEME',IT / SPECI;lJ. PRcvrSIOt.S City of Zephyrhills is named additional insured. CERTIFICATE HOLDER CANCELLATION SHOULD Al-N OF THE ABO',!; e'ESCRIBED POLICIES BE CAN'CE~lED BEF'JRE THE E)PIRATI::>I'J oMS wRITTE' : ZEPH~lUf I P&k'feY(~W;~".,,~~, i-- --------;:I~I~;- ~----~ ---- I I F",H ,)C,:UP'EiK,f ! ; 1,000,000 I H"Tr'~'TE[' I ____..._ I 06/01/08 l~PEI~lsEi,:.E.-';'U~el'O. _ [il_50,()00 : r-/,ErJ f__xP It~I-,1o (In", ppr~l" '1 i $ 10 , 000 ~W~'W'"n~ o[ / cU.:"! _~ i i, 0.0 0 _,O~O:' ~~ ~=fJERAl~:'OF'~,~=F_~~~~~__ : P~'ODU'::-TS - C(i~,tP/oP .:.o.,G,: : i .2 , 000 ! 000 1------ - - ---- -- - - !--- -- 'n_~._ , C )HEn~EC'r ,'~.."~ .II--IT OS/01/0a i '':'aaCc'lcent' ~--_. I! 1,000,000 --i-.--------. 06/01/08 i ~t~~!~~~~~ri:,,;'~1h?F $ i 1 .. L::::'T') '~J~~:'.A(C.I,)H~_____ I "" ;':c r I , ~._,----,- i').,l~I-~ I,{ ---r~~,., I-Fr,JC.~':': : 5 000-000" ~ -' '. .' J ____ I-< '"{ .. t: : -f, I 05/01/08 C~~?~E~~,~~_____'_~~-=-~~~ 0 9 LP~6~o'-- : I ; ~--~-_.~~~ Ji-'=-~: II ! X hj~-/U~Jfi I (lE~ i ~-----_.._~----------------.. 06/01/08 I E':.l'.~,~; '<CI~~_-l; 500~0..?____n_ rE [:oE~:SE - Et, flc,H':E I,; 500 ,000 '--------,------.- i E" C'oE"SE-P')LCY _'IVT I; 500,000 I I I : I i -r--- 06/01/0a I ! ~ent/Leas SchedUled 50,000 42,500 OATS; THEREOF THE 'sSU...,G N3URER WI~~ ENDE,<,VOR TO MA'~ 10 City o~ Zephyrhills Fax: 813 7800005 5335 8th Street Zephyrhills FL 33540-4312 r'!OTICE TO THE CERT1FIC,~TE HO~OER ~;AMED TO THE ~EFT, BUT FAI~URE T::> DC SO ShA,.L iMPOSE t,JC OBLIGATION OR lIAB'LITY OF ,vw Klf.m UPON TI-IE It~S\J'ReR. ITS AGa-.lTS e"R ACORD 25/2001/08) j,EJ;Wrl\'li ,/lPU- @ACORD CORPORATION 1988 From: Kif1"'i Fe-rris At: Greene-Hezel &P.SSCt':. Fa.xIO: ;G: ~)~/ of Ze::lhyrhi!ls C'ate: 412312008 01 :3': Pill Page 1 of 2 10739 Deerwooc Park Boulevard Sl:ite 200 ",:acksonv, I Ie , FL 32256 Tol! Free (866:1 398- ~ 234 P~lone (904) 398-1234 Fax (904) 396--7432 Fax . Kim Ferris To: Econ:t:.-_________u______,____________________________________ Pages: 2 ______________ COl'!:!~any~ City_~~Zephyrhill~___________ 0ate:___4!28.a008J~1 :29:58 PM Fax: (813) !80-0005 _______________ Sllbject;_Ken'!.edy Contractors ~~______________ __________ Message: /i----- /1 . 1I1a.~ I, CIty of Zephymihl Permit ~Iicat!on IlUlldnO D&p8flnIenl ~~5:::~~ Dille Receivlld QwlI.... N8Jl1Il o-w _lie Nala- , o'!""lf' p,,- lIoNnbor I Chlfntr Phon. "....bit' I .. Fee SI..ple liIIe~oldIr AcId.... I!J J A r~~L ~I ~~~~~-:'~'":'M~ RII'llIllElI_-"TM~ ~ NI!WCONSTR B AIlDlAlT D SIGN .0 MOVE 0 IlEM01.lSH L..J INSTALL ~AIR PRQPOSSO use D lII"ft S COMfo' 0 O~ I -. lYPEOFCOD11W01ION IS _OCt< CJ FRAME ~ STEEL t:l OTHeR c- 1 _.._~NlW~~~'. I 8Ul\D1NGSlZE I ~MO ,.f. I eaPOOl'AGEt1~ i~b::r-::KTII1b~"t.....j. 12$1 8Ul.DING I' 4'51, ~L l V~TlONOFTOTAl.CONSlRUCnON IXI IiLl:CTI\lCAL I' 01 l.q2.. I AMP SSlYIC& D . J PRf>GReSS EH~OV 0 ~e.c. . . - o~~~e~~c,Q_7'"",/ol(' 1t~ b ~ PlUMBING '__21. eD~ --1 MO!fr~ CQrlDtnCh'la>.AI/&. . ~~ "~_'A . C8I MGC~cAl IS. oil 'L6" I ,VALUAnO"OFM~IWlICAlINSTAUAl1ON ~I'Z./:: ~_a~ D GAS ~ ROOFING D speCiAllY D O'THEA - form ~ ~. 1'IN1SnE:D J'Lc)()R flEVA110N6 I 40..J "'" I ] FU:IOD ~NE AREA DVES 0110 &I) . _ L_ ~. . ~n. oJ 1.. ,,-.J\51CN\J) ~ . JOB ADIlAIII lIueolYl8lC1N WORK,,~m ._..e ~-'.] I ~d~VJ~e; 1:J6, u-w. I G-C., (... A-z.-;r0' z ~ _= I ~f!/\~::......Ef~<-~~J "H- ~_ I ~:1(JlJjJ8'31 ( -~~ #)tlJf./6'14'~'JVJ I ~ .~~ L!TI[J l.loMIee I" -.-c.P(,11.J25~(jj, r- " I ~ L..:!:L..t:I..J rte!CUIIIlEIIT ~ I -.. 5- ~ COMPANY I - -A-J;fvrcJ" .e ~h. llUlSTBlEO c::ill5 fEE CIIIIIIIIlT Y I,. I Ue.nsd L - I "/ 8lH1..DEI\ SlGNATURIi . IUldIUS !Ll!CTRIc::lAH IlGNATURE . .....,IIBER SIGNATURE :J. U&cIIANICA1. -rtz.:D 81Gt1ATURE I IV Ad*- I -- ,t=..::: ~D AdM.. :rr fU!81DermAl. .-..n I2lI'1c1 PI... (2) ... of 8lAd~ PllNt (1) HI <II I!netuv Fonn& Mini1Iutft 'eft (1 0) ~ dwi' .. tubmllllll cID. R.........llIISile, CGnslNClIon "'-. 8lI1II11Y ~Iti_ & 1 du1Ipster caMl\leRCW. A_(a)"'afll~ p~ (1)8lltdEnllVrForlM. MW1Imum l8lI (111) wClltdng __.......... dale. Requm 0IlI1Ie. CcnsWetllll'l filMs, ~ilo1y FeaIIIlet & 1 citMnp.ter AI~NQUlrem_llUtmeelc:lll1lpli_ ' StGN PERMIT Abdl (J) lclSof E~ Plene. ~0PER1Y ~VIOY ~ laraU NEWCO/lIlIIICIlIln 1llNe1""'" Fll out III'PIioa\ian CDllpll!lel)l. Own8r& eon-.. b8c:k of 8PPIaeliOll. ,.,.... It_S2&UO, e NDIIC. afCllmlll8l1C4lll1lll18'-',*,- (A/C upgrad....,e.C8IKJD) .. All,"' (fot\l1e C1D~ Ot Power of NIptfttt/f (/Dr lneowner) wwld be 'Omval1ll will> ~ Iet,ler'IlIIII_lIlIIlllll1mg.pnte . OVER THE COUNTER .....m1NG (Fronl (If IIppIIC8lICft Oruy) R_ a-- $_ upg"llloos NC Fence. (PIOVlurveyJFOClIt!Pl ~oL _ COIlnIIlM"'lll1 pub*: rOlldMlys.:r-dt ROW ZOO'd Z:0/Z:0 39'v'd tZOO-08L-EIB 'ON XVti 5 9NI~OO~ 3,H'v'~O~~'v' \~ ~ImIns SllIHaAHd:1Z WV 90: 0 I NOW/LOOZlt 111m 5LL9985E18 99:50 800Z:/EI/9B NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County . TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby. made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterlWastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative ServiceslEnvironmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use offill is not allowed in Flood Zone "v" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties. the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) . acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools. air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifia~le cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. I WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVE ENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER 0 TTORNEY BEFORE RECORDING YOUR NOTICE OF COMM ENT. FLORIDA JURA . 1 .--/' ! - : ~~ Notary Public ""'m' ." (1'4:, ~..""" no~ ~~'" ....~/ Expires December 12, 2010 Name of NOlaryQ~rintell"8\'"iiQ/Wilh'6 ,.,.;" 1"-,.,,,, 088 ali 1010 Pasco County Parcel: 03-26-21-0010-01600-0021 001 Page 1 of1 Search Again Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: ParcellD Classification Weekly Archive - Friday, December 07, 2007 03-26-21-0010-01600-0021 (Card: 001 of 001) 10 - Vacant Commercial Mailing Address GENUINE PARTS COMPANY 2999 CIRCLE 75 PKWY ATLANTA, GA 303393050 Physical Address Physical Address N/A Legal Description (First 4 Lines) ZEPHYRHILLS COLONY CO LANDS PB 2 PG 6 PORTION OF TR 16 DESC AS:COM AT SE COR OF NEl/4 OF SEC 3 TH NOODEG 13'18"W ALG Assessment (totals) Ag Land Land Building Extra Features $0 $203,105 $0 $0 Total Assessment Save Our Homes $203,105 $0 Taxable Value $203,105 Use 1000 1000 Land Detail (Card: 001 of 001) Description Zoning Units Type COMMERCIAL 00C2 12,000.00 I SF COMMERCIA 23,717.00 I SF Additional Land Information Tax Area I 30ZH I FEMA Code I Commerlcal Code Building Information (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Description I Year I Units No Extra Features Price Value $87,840 $115,265 $7.32 $4.86 M3012AP Line Value 2007 09 Sales History NYE WILLIAM F & ANDREA R Book/Page Amount 7643 / 1338 $380,000 Previous Owner Year Month Search Again Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Ouestions Other Agency Data: Tax Collector School Board Supervisor of Elections http://appraiser.pascogov .comlsearch/parce1.aspx?sec=03&twn=26&mg=21 &sbb=OOl 0&... 12/1 0/2007 Fire Chief Keith Williams ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: 07--1-3"2- Business Name: vA-f> F1 Business Address: "f5 <;;S (b.l9-1 / 8/ v..LJ Business Phone No.: Business Fax No.: Contact: PLAN REVIEW FEES (j) 0 Site Plan ~ l' ~UIli-FamiIy/Commercia~ (Minimum Charge $25.00 o Plan Revisions DBL SPRINKLER SYSTEMS B 0 - 25 Heads $50 26 plus Heads $100 STANDPIPE SYSTEM o Per Riser $50 FIRE PUMP o Per Pump FIRE ALARM SYSTEM B 0 - 25 Devices $50 26 plus Devices $100 SUPPRESSION SYSTEMS R~~ :: Bother $50 KITCHEN EXHAUST o HoodIDucts OTHER B LP InstaJlation per tank Fuel Tank Installation (Per Tank) o Natural Gas Installation (Per System) o Spray Booth $100 $50 $50 $50 $50 INSPECTION FEES NlC N/C $100 $250 $500 Annual 1 st Re-inspection 2nd Re-inspection 3rd Re-inspection 4th Re-Inspection (Business closed until violations corrected) SPRINKLER SYSTEMS ~ Hydro Undergrounds $45 Hydrostatic Test $65 Acceptance Test $45 Hydrant Flow $75 per system per system Contractor. h~ ~ ~~ , Billing Address: 0 . "'>4s.4- ~C-~ &+ I\\~ ~4:tAk... ~ Billing Phone No.: J4.I-l~ 305".EE( Billing Fax No.: Contact: PERMIT FEE $50 $50 $50 $50 $50 $50 $50 $50 $100 $500 $25 $100 $50 $50 $25 $50 $50 $100 150 Sprinkler Standpipes Fire Pump Hoods Fire Alarm LP Gas Natural Gas F~ Tanks- perlank Sparklers Fire Works Camp Fire Controlled Bum Hood/Duct Place of Assembly Fire Protection Flammable Application Waste Tire Storage Generator < KW Generator >30 KW BiD-Hazard Waste Fumigation Tenting Torch Pot/Applied Haz. Materials B PERMIT TOTALc:=J Comments: GRAND TOTAL J f ~ ~ )'1-fj;!i:~~~~}f~~ - -. - $50 ~ Tent 1 0'x1 0' or greater Fire Pump Fire Suppression System Acceptance B Exhaust Hood/Duct Re-inspection (other than annual) $50 0 Inspection scheduled DBL and cancelled less than 24 hours B Construction Insp. NlC rilInt Emergency Vehicle Ao $50 PLANS TOTALf(-lJi'!t!_JNSPECTION TOTALc=] FIRE AlARM SYSTEM B System Acceptance $50 Recall Acceptance $50 OTHER ~ Fire WalUSmoke Wall LP Gas Natural Gas $15 $25 $25 per wall per lank per system FALSE ALARM FEE 1 st Alarm NlC 2nd Alarm N/C 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 6th Alarm $200 NON COMPUANCE $150 Annual Annual Annual $100 Annual $50 $50 $100 Annual FALSE AlARM TOTAL I $15 $45 $30 perlenl .A7c::fo /L/~O.v $30 DBL Date: /~/2-? I&? Insij~ctor. /d'r/;/ ~A.r~ Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 December 26, 2007 I have reviewed and approved the revised plans for a construction of a mercantile building located at 6901 Gall. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Revised plans show an additional extinguisher located in aisle by electric room. Relocate extinguisher to opposite side centrally located. Front area extinguisher shall be located by either front doors or by hose bib area. 2. Dumpsters and containers with an individual capacity of 1.5 yd3 [40.5 ft3 (1. 15m3)] or more shall not be stored in buildings or placed within 10 ft (3 m) of combustible walls, openings, or combustible roof eave lines. Dumpster shall be a minimum 10' from rear door. (NFP AI) NOT CAUGHT ON FIRST REVIEW. Inspections Required 1. Building Final 2. Additional inspections will be associated with other permits that are required. NOTE: No need to re-submit. A narrative letter can be faxed to Fire Rescue, Attn: Fire Marshal (813) 780-0044. Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 F ire Marshal Kerry Barnett Bus (813) 780-0041 Fax (813) 780-0044 December 13, 2007 I have reviewed and approved the plans for a construction of a mercantile building located at 6901 Gall. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Building construction shall be in compliance with the Florida Fire Prevention Code. 2. Install knox box on front of building near entrance at a height of6'. Location can be determined once construction is near the end by contactor and Fire Marshal. An application has been provided. 3. Address on front units shall be 6" in height. 4. Separate plans are required to be submitted to obtain a permit for the sprinkler system. Plans shall be in accordance to the edition (2007) ofNFPA 13. Plans shall provide calculations, all details and specs. FDC for sprinkler system shall be a single 5" Stortz outlet with cap. 5. Plans are required to be submitted to obtain a permit for the alarm system for sprinkler monitoring. Plans shall be in accordance to the latest addition of NFP A 72. Plans shall provide battery calculations, all details and specs. Copy of certificate of monitoring company also will be required. 6. Plans are required to be submitted for any gas installation with all details and specs associated with the install. 7. Extinguishers shall be relocated in upper area to location at either end by stairs. Lower level extinguishers shall be located; 1 at rear door, 1 at front area, 1 by electrical and 1 centrally located across from electrical. Inspections Required 1. Building Final 2. Additional inspections will be associated with other permits that are required. " ~, :;:0(1)"'. ~ N .> :;; .. F if ~~ '" ;g nr~iI ~O~! o 5"S f'T1 = " ;;: . ; ~~ 0 ~ ~~ e tTI~i .. II ~ ~ II . 0", m .. . ~ .. a> 0 CO ~ ~ Ii: I"l .. ~ r'" .. !;; C "'.. .. .. '" ~~ iii .. O!:j C . -------- !!l .. .>: I: if ~ ~5 ... '1 .. ill !~{;) I: " .. ~----- ~ ~ '" ~ ! . J; ~!UII" c .. . .. ~ .: Ii ~ ~[ .. 0 ~ ;~ ;;oJ} ~ .. o :r- :;0 5i .. '" i~; ~~g . ..c l,I) a ~~~ '" z . n .. i~ ~ " ~ ~~ii '" .. ! i;i n .: 00 ~ ~ ~ "l s.~ a; ~ ~ ~ I'" ~ ~ d iJ ~ ~ 'I" ~. l.ol .q ::l 0 ~ ! " '" l/lPt/l :I: ~ w I~ ~~~~~ .. ~ -< I~ '" n~ . '" ~"~O>~ <> ... N '" IF =", ~ ~11~11~ ?< 11 o.qq q "'" :I" 0 . \~j ~ ~ ('<::. f1b 1 ili ~ 1 1 I' 1 I 1 1 I ,I .., I ,I " I ,I 1 I 1 \', 'I 1 ,.,~ " ~i I 1 I " --!-~ ~ r I '--;"~N~;\;;I -- - ',-" ) ~h~ ~in " III ~ 'D'I 1 1 ., I I 1 I I I I I 1 , I k 1 (,) I ... :::;co OJ V,'006 ~O~~ ,." I ,Vl S;:~1Il~ '1;:GJ~d ~N~~ ;:::J I z-< ~~fTl~ ~ --.j g ,~ ~~ ><$ o~ "'i: i~ ::j~ ~~ ~ " ., - ,- ---- ~ ~- - ~ ,- - "'"""--'-- -.--- n~1 ~II E~II :11 ;;-;!IN 1==; !II ;:E :z ~I i . 5 ... ~& ~ ... - i U~!';I~ill'l ; l!i~~iSliH !il! ~ . ,'11 pi III Ii' ..... ~ ~P!" E 8- if_ i mf . ~ 8 f H NAPA. Gall Blvd - 6901 (No Contractors) SQ. FEET PRICE MAIN OR LIVING: 7.800 $ 96.13 OTHER AREA UNDER ROOF: - $ 96.13 OTHER: - $ - VALUATION $ 749,814.00 FEE SHEET $ 2,180.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 2,283.60 ELECTRICAL: $ 490.50 PLUMBING: $ 327.00 MECHANICAL: $ 228.90 SUB-TOTAL $ 3,330.00 RADON: $ 78.00 TOTAL $ 3,408.00 SEWER: $ 2,822.04 WATER: $ 899.96 IRRIGATION: $ 266.00 TOTAL: $ 3,988.00 WATER METER 1":1 $ IRRIGATION METER 1": $ 320.00 I 320.00 FIRE DEPARTMENT FEES PLANS TOTAL: $ 468.00 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 468.00 PUBLIC SAFETY IMPACT FEES POLICE $ 1,271.40 FIRE $ 1.365.00 5% $ 131.82 TOTAL: $ 2,768.22 SUB-TOTAL $ 11,272.22 IplUS 25% T1F to pick up Permit If not paying Total 75% due before @ Premeter Inspection PARK IMPACT FEESI $ Not Applicable SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - Not Applicable Not Applicable T I F'S:I $ 99%1 $ 1%1 $ 16,528.20 I 16,362.92 1 165.28 I 25% Total 99% 1% TOTAL: $ 27,800.42/ All TIFs must be paid in total before Premeter Inspection $4,132.05 75% Total $12,396.15 $4,090.73 99% $12.272.18 $41.32 1% $123.97 NAPA - Gall Blvd. 6901 (No Contractors) SQ. FEET PRICE MAIN OR LIVING: 7,800 $ 96.13 OTHER AREA UNDER ROOF: - $ 96.13 OTHER: - $ - VALUATION $ 749,814.00 FEE SHEET $ 2,180.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 2,283.60 ELECTRICAL: $ 490.50 PLUMBING: $ 327.00 MECHANICAL: $ 228.90 SUB-TOTAL $ 3.330.00 RADON: $ 78.00 TOTAL $ 3,408.00 SEWER: $ 2.822.04 WATER: $ 899.96 IRRIGATION: $ 266.00 TOTAL: $ 3,988.00 WATER METER 1":1 $ IRRIGA liON METER 1": $ 320.00 I 320.00 FIRE DEPARTMENT FEES PLANS TOTAL: $ 468.00 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 468.00 PUBLIC SAFETY IMPACT FEES POLICE $ 1.271.40 FIRE $ 1.365.00 5% $ 131.82 TOTAL: $ 2,768.22 SUB-TOTAL $ 11,272.22 IplUS 25% TIF to pick up Permit if not paying Total 75% due before @ Premeter Inspection PARK IMPACT FEESI $ I Not Applicable SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - Not Applicable Not Applicable I TI F'S:I $ 16,528.20 I 99%1 $ 16.362.92 I 1%1 $ 165.28 25% Total $4,132.05 75% Total $12,396.15 99% $4.090.73 99% $12,272.18 1% $41.32 1% $123.97 TOTAL: $ 27,800.421 All TIFs must be paid in total before Premeter Inspection ~PrPA SQ. FEET PRICE MAIN OR LIVING: 7,800 $ 96.13 OTHER AREA UNDER ROOF: - $ 96.13 OTHER: - $ - VALUATION $ 749,814.00 -- -... FEE SHEET $ r2,178.00 ./ 2..V60' ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 2,281.56 ELECTRICAL: $ 490.05 PLUMBING: $ 326.70 MECHANICAL: $ 228.69 SUB-TOTAL $ 3,327.00 RADON: $ 78.00 TOTAL $ 3,405.00 SEWER: $ - WATER: $ W\I-\ -'ilv ') IRRIGATION: $ - TOTAL: $ 3,722.00 ---t";;R;'f-# " WATER METER: $ 320.00 /I IRRIGATION METER $ 320.00 FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 1 ,271.40 FIRE $ 1,365.00 5% $ 131.82 TOTAL: $ 2,768.22 SUB-TOTAL $ 10,535.22 I PARKIMPACTFEESI$ ~ SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - TI F'S: $ 16,528.20 99% $ 16,362.92 1% $ 165.28 TOTAL: $ 27,063.42 I Hz(!~ ~l() City of Zephyrhills Water and Sewer Impact Fee Calculation Land Use Type: Retail 7800 No. of Square Feet Water Distribution System Wastewater Collection System Wastewater Treatment Plant Ca acit TOTAL Impact Fees Withi $ $ $ $ Outside City Limits $ 1,124.96 $ 2,261.16 $ 1,266.39 $ 4,652.51 Napa Auto 6901 Gall Blvd. 1) Nothing is to be built or installed in R.O.W. without the R.O.W. use permit. 2) Building to be 8 inches above the crown of the road or to the specifications of an approved engineered site plan. 3) Compaction test will be required. 4) Batter-board survey will be required. 5) All block walls shall be inspected in lifts of at least 12 feet 6) All setbacks shall be met. 7) All welds shall be inspected by an independent inspection agency and the reports shall be turned into the Building Dept. 8) All A.D.A. (Chapter 110fthe F.B.C.) codes shall be met. 9) All signage shall be in accordance with ordinance # 870-04. City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: t-,j()'-PA ~'\D Site: \2-7-07 ,,~O\ WI bL'L\.\ 8/1Jd Date Received: Permit Type: &J"'('^.)"'OiJL.)~ I"lf]- N€A.-U Q-<2J~('. Approved wino comments: 0 Approved withe belDw comments: ~ Denied withe belDw comments: D 5f:-6 L ~ YhI41 OV( S-1I6bT This comment sheet shall be kept with the permit and/or plans. ),2//-1- Date Contractor and/or Homeowner (Required when comments are present) j IIi ill; ~~" ~ml!l. ~!illla a8' . i i~; :l!lm P!I iU! .. ~Ii Ii i ;~ ~ i H~ ! e;~ It =~'" I :;;p; ! net !I ~ i 03....... ;:g .~~ ~ o ; g ~ ~ ;.~ LI~ ~ '" I~ ~~ ~ llJ'\J 0 ~~~5 m~i . . .. = ~ II ~ . ~ I; "' .. "' . .. ~ .. . .. ~ ~ ~ ~ ~ ~ ~ ~ ~ <;! o c '" -..J:t0l ~ ~~~ ~ 000 "" "" "" -< .... .... ~ ~ ~ ~9~~~ ~ ~Rl:tlll~ "0 <;!i';<;!i';<;! 1< ~~ L 2g "'.. ~/' <;!5 ~ ... .. e ... n ... Z ... o .. Ii ~ o .. I ~____----- '" ~ iJ rO" }:> z' OJ!; m >< ~~ .l> I' '? ~ ',,-~ '"1 2''': m ~;:o, ~ ,~ r , '. ,(. c: I ~ I ~ ~ " ~ n;l; ~~ o ~ .. i'; '" '" qqq q . ~ c ~ I ... ::::;OJ 00 <.0005 ~o~~ ....., I nn S;:: ...j:>.. (J)"" =GJ~2;J :;":N~;:g ~ I z-< ~ ...j:>..rl~ ~ ---.J S2 ,W1 ~~ ><$ 0,., i~ :::j~ ~~ ~ 1 :1; !, :i! it:, I 1 " .,- . ~: I I . .,. I I I . I I 1 I I . I" II I · ,~: i . '"1 · ~! ~i I · I " -+-/I L.. ~ ''---____-1 I ....~ ,," J __~k\">;" I ---------., I () ~.) 58 "tTJ o. "'Tj -:;~~ N ;>. r --J ~~~ t::: r~"- i:...) ~h~ 11,......,~ ~~h ...14l ~ , ) '. ,__. ,< v ------ ---~ ......' - ~.:- - '-",--- ---.- nil E~il III "=;!!J;C NZ'J ~rPllll dId '1'''' "f"aD j: - co ... ;l;~ i ,hi:1. ~.~ i ~Ii & I~ j;~ ~= z. ='lllil -~. III ;I E I imli! ~d.f ~IE ... 31 z z . . I. i!C11i ;;j . Ii ;:: ;:: i I I i I :H~H ~ ~ ~f ~E F;; ... ! IP'" ~ f . .... .,. I i ;H!! I ~ Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs FLAlCOM 2004 v2.5 - Form 400A-2004 Method A: Whole Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: Napa Owner: Napa Auto Parts Addressl: ~ Gall Boulevard Address2: ~10\ Description: Zephyrhills Type: Retail Jurisdiction: ZEPHYRHILLS, PASCO COUNTY, FL (611600) Cond Area: 7800 SF Cond & UnCond Area: 7800 SF No of Storeys: I Area entered from Plans 7800 SF Permit No: 0 Max Tonnage 5 If different, write in: City: State: Zip: Class: Zephyrhills Florida 33541 New Finished building 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 Compliance Summary Component Design Criteria Result Gross Energy Use 11,118.2 12,070.1 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HV AC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS None Entered PIPING SYSTEMS None Entered Met all required compliance from Check List? Y es/N o/NA IMPORTANT NOTE: An input report of this design building must be submitted along with this Compliance Report. 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 2 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Y"......_ \, \ l. . t. _ 'tl ~/ ( t Prepared By: ~ Building Official: ~"'"-1: Date: \.r} S 1),007 Date: -l1. '-U -OJ I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: MITCHELL M. DEUTSCH Reg No: 93755 Electrical Designer: J. DOUGLAS RIDDLE II Reg No: 40423 Lighting Designer: J. DOUGLAS RIDDLE II Reg No: 40423 Mechanical Designer: JUSTIN R. HARDY Reg No: 67084 Plumbing Designer: JUSTIN R. HARDY Reg No: 67084 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 3 Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) Building End Uses Design Reference Total 92.12 100.00 $11,118 $12,070 ELECTRICITY(MBtu/k 92.12 100.00 Wh/$) 220163 239012 $11,118 $12,070 AREA LIGHTS 30.13 37.02 72027 88486 $3,637 $4,469 MISC EQUIPMT 21.00 21.00 50178 50178 $2,534 $2,534 PUMPS & MISC 0.01 0.01 26 26 $1 $1 SPACE COOL 29.25 28.78 69902 68788 $3,530 $3,474 VENT FANS 11.73 13.19 28030 31534 $1,416 $1,592 Credits & Penalties (if any): Modified Points: = 92.12 I PASSES I 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 4 Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) External Lighting Compliance Description Category Allowance Area or Length ELP A CLP (W/Unit) or No. of Units (W) (W) (Sqft or ft) Ext Light 1 Plaza Areas 0.20 7,800.0 1,560 170 Design: 1530 (W) I PASSES I Allowance: 1560 (W) Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- In (sq.ft) Tasks CP CP ance Napa ,001 Sales Area 7,800 I 7 4 PASSES I PASSES I Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) System Report Compliance AHU-l Split System Constant Volume Air Cooled No. of Units thru 4 Split System < 65000 Btu/hr 4 Component Category Capacity Design Eff Design IPLV Comp- Err Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 BtuIh 13.00 13.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply)- 0.80 0.90 PASSES System -Supply Constant Volume I PASSES I 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 5 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Err Err IPLV IPLV liance I None I Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance I None I Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-inlhr Thick [in] Thick [in] [F] .SF.F] I None I 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLNCOM 2004 v2.5 6 Project: Napa Title: Zephyrhills Type: Retail (w'EA File: Tampa.tmy) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met D System 407.1 HV AC Load sizing has been performed D Ventilation 409.1 Ventilation criteria have been met D ADS 410.1 Duct sizing and Design have been performed D T&B 410.1 Testing and Balancing will be performed D Motors 414.1 Motor efficiency criteria have been met D Lighting 415.1 Lighting criteria have been met D O&M 102.1 Operation/maintenance manual will be provided to owner D Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it D Report 101 Input Report Print-Out from EnergyGauge F1aCom attached? D 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 7 EnergyGauge Summit v3.10 INPUT DATA REPORT Proiect Information Project Name: Napa Orientation: East Project Title: Zephyrhills Address: 6855 Gall Boulevard Building Type: Retail Building Classification: New Finished building State: Florida Zip: 33541 No.of Storeys: GrossArea: 7800 SF Owner: Napa Auto Parts Zones No Acronym Description Type Area Multiplier Total Area [sf! [sf! I Napa Napa Auto Parts CONDITIONED 7800.0 I 7800.0 0 Zephyrhills Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft) [ft) plier [sf! [cf! In Zone: Napa I Napa Napa Auto Parts Sales Area 50.00 156.00 20.70 I 7800.0 161460.0 0 Zephyrhills Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [WI Ctrl pts In Zone: Napa In Space: Napa I Recessed Fluorescent- General Lighting 3 59 177 Programmable timer I 0 No vent without Daylighting 2 Recessed FI uorescent - General Lighting 2 59 118 Programmable timer I 0 No vent without Daylighting 3 Recessed Fluorescent- General Lighting 4 113 452 Programmable timer I 0 No vent without Daylighting 4 Recessed Fluorescent - Display/Accent 2 113 226 Programmable timer I 0 No vent Lighting without Daylighting 5 Recessed Fluorescent - Display/Accent 17 59 1003 Programmable timer I 0 No vent Lighting without Daylighting 6 Recessed Fluorescent - General Lighting 108 59 6372 Programmable timer I 0 No vent without Daylighting 7 Recessed Fluorescent - General Lighting I 162 162 Programmable timer I 0 No vent without Daylighting 8 Recessed Fluorescent - General Lighting 13 324 4212 Programmable timer I 0 No vent without Daylighting 9 Recessed Fluorescent - General Lighting 4 460 1840 Programmable timer I 0 No vent without Daylighting 12/5/2007 EnergyGauge Summit v3.10 Walls No D...cription Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/cf] [h.sf.FlBtu] [Btu/sf.F] In Zone: Napa I Front Store East 0.75 in. stucco, 50.00 20.70 I 1035.0 East 0.0838 11.224 50.24 11.9 0 2 "styro,8"CMU, I x2 x24"oc,airspace,0.5" gyp 0 2 Rear Store West 0.75 in. stucco, 50.00 20.70 I 1035.0 West 0.0838 11.224 50.24 11.9 2"styro,8"CMU,lx2 x24"oc,airspace,0.5" gyp 0 3 Side Store North 0.75 in. stucco, 156.00 20.70 I 3229.2 North 0.0838 11.224 50.24 11.9 2"styro,8"CMU,lx2 x24"oc,airspace,O.5" gyp 4 Side Store South 0.75 in. stucco, 156.00 20.70 I 3229.2 South 0.0838 11.224 50.24 11.9 0 2"styro,8"CMU,lx2 x24"oc,airspace,0.5" gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Mult Total Area [Btu/hr sf F] 1ft] 1ft) iplier [sf] In Zone: Napa In Wall: Front Store East I East Window User Defined No 1.2500 0.70 0.58 )2,00 14.00 I 168.0 0 In Wall: Side Store North I North Window User Defined No 1.2500 0.70 0.58 23.00 12.00 I 276.0 0 Doors No Description Type Shaded? Widtb H (Effec) Multi Area Condo Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Ib/cf] [Btu/sf. F] [b.sf.FlBtu] In Zone: Napa In Wall: Rear Store West I West Door Metal No 8.00 8.00 I 64.0 0.0957 16.80 0.76 10.45 0 siding!RIIBattlO.5 "Gyp 2 West Door 2 Metal No 7.00 3.00 I 21.0 0.0957 16.80 0.76 10.45 0 sidinglRIIBattlO.5 "Gyp Roofs No Description Type Widtb H (Effec) Multi Area Tilt Condo Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] (Btu/sf. F] [Ib/cf] [h.sf.FlBtu] In Zone: Napa I Roof Mtl Bldg RooflR-19 156.00 50.00 I 7800.0 0.00 0.0492 1.34 9.49 20.3 D Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] 1ft] 1ft) ISf] [Sf] In Zone: In Roof: D Floors No Description Type Width H (Effec) Multi Area Condo Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] (Btu/sf. F] [Ib/cf] [b.sf.FlBtu] In Zone: Napa 12/5/2007 EnergyGauge Summit v3.10 2 Floor 1 ft. soi I, concrete floor, carpet and rubber pad 156.00 50.00 7800.0 0.1745 54.00 108.00 5.73 o t Systems AHU-l thru 4 Split System Constant Volume Air Cooled Split No. Of Units 4 System < 65000 Btu/hr Component Catej!ory Canacity Effieiencv IPLV 1 Cooling System (Air Cooled < 65000 Btulh Cooling 60000.00 13.00 8.00 0 Capacity) 2 Air Handling System -Supply (Air Handler (Supply)- 1000.00 0.80 0 Constant Volume) Plant Equipment Category Size Inst.No Eff. IPLV D Water Heaters W-Heater Description Capacit]Cap.Unit lIP Rt. Efficienc} Loss 0 Ext-Lighting Description Category No. of Watts per ArealLen/No. of units Control Type Wattage Luminaires Luminaire (sf/ftlNo] (WI 1 Ext Light 1 Plaza Areas 9 170 7800.00 Astronomical Timer Co 1530.00 0 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F) [inl [in) 0 Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes (Btu/h.sf.F) ASHUL TntAllFr User Defined 1 1.2500 0.7000 0,5800 0 m Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHea Used [h.sf.F IBtu) [ft] (Btu/h.ft.F] [Ib/cf] t 187 Matll87 GYP ORPLAS No 0.4533 0.0417 0.0920 50.00 0.2000 0 BOARD,1/2IN 178 Matll78 CARPET WIRUBBER PAD Yes 1.2300 0 265 Matl265 Soil, I ft No 2.0000 1.0000 0.5000 100.00 0.2000 0 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 0 267 Matl267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 0 215 Matl215 POLYSTYRENE,EXP, No 8.3350 0.1667 0.0200 1.80 0.2900 0 2IN, 105 MatlI 05 CONC BLK HW, 8IN, No 1.1 002 0.6667 0.6060 69.00 0.2000 0 HOLLOW 256 Matl256 WOOD, SOFT, 1-1/2IN No 1.8939 0.1250 0.0660 32.00 0.3300 0 12/5/2007 EnergyGauge Summit v3.10 3 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 0 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 0 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 0 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 0 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct (Btu/h.sf.F] [Btu/sf.F] [Ib/ef] [h.sf.F /Btu] 1010 0.75 in. stucco, No No 0.08 11.22 50.24 11.9 0 2 "styro,8 "CMU, I x2x24 "oc,airspace,O. 5" gyp Layer Material Material Thickness Framing No. [ft] Factor I 267 0.75" stucco 0.0625 0.000 0 2 187 GYP OR PLAS BOARD, I 12IN 0.0417 0.000 0 3 215 POLYSTYRENE, EXP., 2IN, 0.1667 0.000 0 4 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.000 0 5 256 WOOD, SOFT, 1-1I2IN 0.1250 0.000 0 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] (Btu/sf.F] [Ib/cf! [h.sf.F/Btu] 1020 Metal siding/RIIBattlO.5"Gyp No No 0.10 0.76 16.80 10.5 0 Layer Material Material Thickness Framing No. [ft] Factor I 4 Steel siding 0.0050 0.000 0 2 12 3 in. Insulation 0.2500 0.000 0 3 187 GYP OR PLAS BOARD, I 12IN 0.0417 0.000 0 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] (Btu/sf.F] [Ib/cf! [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 0 Layer Material Material Thickness Framing No. [ft] Factor I 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 0 2 23 6 in. Insulation 0.5000 0.000 0 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct (Btu/h.sf.F] (Btu/sf.F] [Ib/cf! [h.sf.F /Btu] 1057 I ft. soil, concrete floor, carpet and rubber No No 0.17 54.00 108.00 5.7 0 pad Layer Material Material Thickness Framing No. [ft] Factor I 265 Soil, I ft 2.0000 0.000 0 2 48 6 in. Heavyweight concrete 0.5000 0.000 0 3 178 CARPET W/RUBBER PAD 0.000 0 12/5/2007 EnergyGauge Summit v3.10 4 ACORD. CERTIFICATE OF LIABILITY INSURANCE OP'D KF I DATE (MM/DDIYYYY) KENNE-3 04/28/08 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONL Y AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AMEND. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE I NAIC # , 24112 02186 westfi.ld Insurance COJllp..ny PRODUCER Greene-Hazel & Associates ,Inc. 10739 Deerwood Park Blvd, #200 Jacksonville FL 32256-2873 Phone: 904-398-1234 Fax:904-396-7432 INSURED i INSURER A ! INSURER E CNA Insurance Companies Kennedy Contractors, Inc. Attn: Hr. Michael Carp' 1495 Forest Hills Blv~ Ste A West Palm Beach FL 33406 i IUSURER C , i INSi IRER 0 ~ ! INSUREFi:' E COVERAGES THE POLICIES OF H'.lSURt:l!'.ICE LISTED BELeN'..' Ka.,VE BEH.J ISSUED TO THE InSUREC1I'-L,Q,MED,AECNE FOR lHE P()L!CY PERIOD Ir-.IOIC,c..TEO NOT'NIlH::iLt:lNDING p.NY REOUIREt,!\EHT. TERM OR COi'lDlTlON OF ,o"NY CON'TRJI,CT OR OTHER OOCUt..1Er.rr ',I'./[TH RESPECT TO \/'/HICH THIS CERTIFIC;:.TE r~1.o:i BE ISSUED OR Mil,,/" PERTAIN, THE H>JSURANCE AFFORDED 81 THE POLlC1ES DESCRIBED HEREIr>J fS SuBJECT TO P-.!...~ THE TERMS, !::)<:CLUSIONS AN[; COND~TION3 0F SUCH POLlCIE:.:: A,G(:;REGATE LlI\rIlTS SHOWN M~,Y HAVE BEEN REDUCED BY PAID CLAIMS LTR NSRd TYPE OF INSURAt,CE POLICY NUMBER I DATE {MM/DD/YYI i r DATE' (MM/DD/YYI LIMITS , i GENERAL LIABILITY EA:H (lCCURRENCE $1,000,000 A ~~'1ERCIP.L ca.JERAL ""-BIL'TY CMM1642516 06/01/07 06/01/08 I PR~MI:;ES (Ea occur~nce) $150,000 I -LAII1'- W-E !XJ--.-u- r-rlEO E},'P (.A.n\l 0rli3 person) $ 10,000 i l.',.:J ....u '---.------- l.)l_l~ t"< , I PERSON-A.L &. ADV INJURY ! 1,000,000 . , gJ'L AGGREGATE LIMIT APPLIES PER GEN:::RAL AGGREGATE $2,000,000 PRrJDUCTS COMPJOP AGG $2,000,000 n POLICY iXl :;~gT nLOC I I AUTOMOBILE LIABILITY ! I COMBINED SINGLE. LIMIT 1..1,000,000 A ~ AN! AUTO CMM1642516 I 06/01/07 06/01/08 i [Ea accident) H""MC^~" I , I $ 30DI~1- INJURY SCHEDULED AUTOS (Per Derson) ! I HIRED I>,UTOS 80DIL Y INJUR'{ 1$ ~ ;~;:~ED P:;: (Pe: rKC-!dent) I A Damage CMM1642516 I 06/01/07 06/01/08 I PROPERTY D.AM.A.GE T i I (Per accident) !$ I I GARAGE LIABILITY I I AUTO Or'~L Y - EA ACCJDE.NT $ I H #,.,. ,".UTe I I E.A,.A.CC ! $ I I DTHER TJOt\N , AUTO ONL Y ,LI.GG 1$ I I , , ~ESS/UMBRELLA LIABILITY EACH OCCURRENCE $5,000,000 A X I O::CUR 0 CLAlr,AS tvLADE CMM1642516 06/01/07 06/01/08 AGGREG..o.,TE $5,000,000 ~ [ECUCTI8LE $ $ jX I RETErJTIOt J $0 , $ WORKERS COMPENSATION AND X ITC;~\tl':;ii5 I IOJ~. , B EMPLOYERS' LIABILITY 2083385468 06/01/07 06/01/08 PJ,fT- PROPRJETClRJPARTNERJD<ECUTJVE t:._L... EACH .A.CClDENT i $ 500 ,000 OFFICEPJMEMBER EXCLUDED-' E.L DiSEASE - E.~ EMPLOYEE! $ 500 ,000 jlf ye~. describe under I SPECIAL PROVISIONS below EL D'SEA.SE - POLICY LIMiT $500,000 I OTHER ! I I I Leased/Rented , I B I 2083385437 I 06/01/07 06/01/08 , Rent/Leas 50,000 , Scheduled I I I ! Scheduled 42,500 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS City of Zephyrhills is named additional insured. CERTIFICATE HOLDER CANCELLATION ZEPHYRH SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAvOR TO MAIL 10 DAYS WRITTEN City of Zephyrhills Fax: 813 7800005 5335 8th Street Zephyrhills FL 33540-4312 NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUT ZE ACORD 25 (2001/OB) @ACORDCORPORATION19BB KENNEDY CONTRACTORS, INC. April 28, 2008 City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 Gentlemen/Ladies: Please accept this letter as your authorization to allow Daniel F. Kennedy to apply for, sign for or pick up any permits, certificates of occupancy or certificates of completion on behalf of Kennedy Contractors, Inc. Thank you for your assistance. Sincerely, TFK/ay State of Florida County of Palm Beach Signed before me this 28th day of ApriL 2008, by Thomas F. Kennedy who is known to me. -- . .".:'.'.~.'''--'' L~~:t\. \.. i;'.' D. !tJIIC. State of Florida !'~ ': .~i"ey N Yeomans ~~ J! r"y Commission D0492553 ~ 0, f\.d" Expires 11/20/2009 ". ....... .-- 1495 FOREST HILL BOULEVARD. SUITE A WEST PALM BEACH, FLORIDA 33406 CGCA28023 I AC# 27 8 2 8 4 5 I I I I I I I I I STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD SEQ#L06090600478 : . LICENSE NBR 09 06 2006 000000000 CGCA28023 The GENERAL CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter Expiration date: AUG 31, 2008 489 FS. KENNEDY, THOMAS FRANCIS KENNEDY CONTRACTORS INC 1497 FOREST HILL BLVD SUITE G WEST PALM BCH FL 33406 JEB BUSH GOVERNOR DISPLAY AS REQUIRED BY LAW SIMONE MARSTILLER SECRETARY "'"w uu~ PALM BEACH COiJNTY LOCAL BUSINESS TAX RECEIPT EXPIRES: SEPTEMBER - 30 - 2008 CLASSIFICATION KENNEDY.CONTRACTORS INC KENNEDY THOMAS FRANCIS ** LOCATED AT 1495 FOREST HILL BLVD #A WEST PALM BEACH FL 33406 C/WIDE $369.60 TOTAL $369.60 This receipt Is hereby valid for the above address for the period beginning on the first day of October and ending on the thirtieth day of September to engage In the business, profession or occupation ot: GENERAL CONTRACTOR CGCA28023 L THIS IS NOT A BILL - DO NOT PAY ~~D. PBC TAX COLLECTOR L_______$369.60 OCC 049 1507828 08-02-2007 ANNE M. GANNON TAX COLLECTOR, PALM BEACH COUNTY THIS DOCUMENT IS VALID ONLY WHEN RECEIPTED BY TAX COLLECTOR 2001-01631 STATE OF FLORIDA PALM BEACH COUNTY LOCAL BUSINESS TAX RECEIPT EXPIRES: SEPTEMBER - 30 - 2008 OC-032 CLASSIFICATION KENNEDY CONTRACTORS INC KENNEDY THOMAS FRANCIS ** LOCATED AT 1495 FOREST HILL BLVD #A WEST PALM BEACH FL 33406-6052 CNTY $27.50 TOTAL $27.50 I This receipt is hereby valid tor the above address tor the pe~iod beginning on the first day of October and ending on the thirtieth day of September to engage in the business, profession or occupation of: GENERAL CONTRACTOR THIS IS NOT A BILL - DO NOT PAY PAID. PBC TAX COLLECTOR $27.50 DCC 049 1507827 08-02-2007 CGCA28023 ~ ANNE M. GANNON TAX COLLECTOR, PALM BEACH COUNTY THIS DOCUMENT IS VALID ONLY WHEN RECEIPTED BY TAX COLLECTOR ~.~~'V.... I~"~~'II~~'~'~ 'rT~t... "~q~::~" " , I'. ;1. "i.. AC# J2 516 80 STATE-OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARDSEQ# LO? 0 6 0501388 : . LICENSE NBR . 06 05 2007 0607'61916 B000271S The BUSINESS ORGANIZATION Named below IS QUALIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2009 (THIS IS NOT A LICENSE TO PERFORM WORK.. THIS ALLOWS COMPANY TO DO BUSINESS ONLY IF IT HAS A QUALIFIER.) KENNEDY CONTRACTORSINC 1495 FOREST HILL BLVD STEA WEST PALM BEACH FL 33406 CHARLIE ,CRIST HOLLY BENSON GOVERNOR SECRETARY Dale: 5/1312008 03:30 PM Fax From: Pages: Date: Subject: Message: Sender's Fax IC3AvARO<' Oage ~ of 3 Phone: (727) 544-8841 Fax: (727) 828-0529 Angel!ca~~~_____u_______1"o:____ BUILDIN~ DE PARI-M EN!_____ 3 ________ Fax:__~81 ~LZ80-0005 ___________ 5/1312008 02:33:08 PM Phone: ( ) - CERTIFICATE OF INSURANCE Date: :1'312008 03:30 PM Sender's Fax !e: 3.IWAROt. "'age 2 of3 ACJJBO. CERTIFICATE OF LIABILITY INSURANCE OP 10 Al1 ca~-~ 05/13/08 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATIOt.l ONL Y AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AMEND, EXTEND OR AL TER THE COVERAGE AFFORDED BY THE POLICIES BELOW, DATE IMWOCNYYi) "ROOuCER Bay Area Insurance Inc. 9P67 Belcher Road Pinellas Park FL 33782 Phone:72i-S44-8841 Fax: 727-544-SS42 INSURERS AFFORDING COVERAGE , NAIC# 'NSURED ! Ir'~:SJ<fF;' Assoc:. tnc.ustries Ins:. S.xvicti ~ i--..------..-~-----.---------"--.------~---.__r---------'. :I'J$ _ h'~:h' E Commercial Air and Applicance Services Inc. 2418 41st Street E Bradenton FL 34208 t ~:."-=~~~----------._-----------L~_':~~--.__ I :~'JS_:-:EF, [i I I--~---_._------------------------,-----_..- : Ir'J5U-:t.f=,'t: ' COVERAGES TH::- =OLlCIES OF Ir~SiJPA\CE LlSlCD B:-L0\N f',AVE BEE\ is;;UE[J TO TH~ 1f~~URFc-; r-.i,.:l,M-~ ,o.,8()'JF F'JR T-~ DOLl::_',' :=>EPIOD ~JC<-,A;'::D NorvViT-STAi'lrJd\iC.; .4J\jv RE:',U REfdE~C. TFF'M OR C(INJITv:r'J OF ~NY C')t~T~.ACT ,:IR OTHER co,:urdEf-.jT "/'./i'-H RESPECT L-' ',.vf1iCH TH',3 CERflFIC,L-E r";A'( BE r38UED OR MAv P~P-AJh!, THF n::,up4JK:E ):,f::FOh':;EC =-y "':"HE' PO,,, (iF; :~E:::;CPI8ED H=RFi;-.j IS SUE=:,JE:-:T;() AL_ TI..iF TFRI\,1S E:~L:LUSIO("J3 llND I....ONC,1TI0r,J3 :,J:' SlJCH PCLICIES";;':GR=!~;,qE UMITS ~:;hOI!'/N MAy' H'::".=': 3EEN F'EC_')CED By PA, [i ':L'::';,:rd::~ L ~~ iifs~an TYPE OF Ir,SURANCE POLICY NUMBER ! (;ENERAL LIABILITY A : x~i C)I,M::R'.,N. :;EI.JER^cLl"8,,'TY ! LBA006134 I : I ':L". MS ~,I;>DE [_~ ')Xi_,,' I 1 P01.:JCYEFFECTiVE I DATE (MMIODr(YI LIMITS 02/08/0S EACH CCCI_R;EI'JCE --C',~!7?~r,,!~_} 02/0S/09 ~PEI,1ISES(Ea'>:uen.o.~_~ 50 ~~Q... i i'.1ED E."iF r An'~ ('N' ~,er~(1i1' i :!_~.i. 0 0 0 __.__ I PEV;:'rJ~~ ,C[ nu;. 1\ 1,000,000 ~~~;B:~,- A.:(;O~':'.~~_$~!~~~~OO-.- :_..F'R,:{1ucr"::"'~("'~(PA('G i ~ 1, O~O, 000_._ ---+- I u~u1-,900,_Q.00 '--~ ------------ x : AUKMOBlLE U;.BllIl"r c i -~ni ,--, ~_ _ -1 ~..L :I\V(~=D ;Cl,UTI):; R1 SCH=DULEDA'.'.)5 i HirED A_ TO;: I ! :'Jm+~~'\i\,1NEr::-, ..;UL:,;:. ': f--.---1------...--__ I I I i (lARAGE LIAa;LITY-~ 'I ."l'jV A'JrC' ~-- :::I\V_= _'h"i dCC,("', n I! 500,000 -<\IJTO 3383612 02/0S/08 I l( 02/0S/09 l_______ , , 13,:D ~ ',' :r'l.il)~~-- , IF'8!- aCI:-':i';.r-~.' ;, I I! ~ , L..____._.--I-.._____ : f="'Rl:iPEr:Ty :.:.c."HI:,';E i ! \PAr3C: Jl2rU ! f I "'~O,)..L" -'<cTf'P:Ji ~ I ~~f~)L';li- ..~~H:---=~=----. E)<CESSfUM8RELLA LlA81U'fY ()(,CUF' C '-:.L,~i!v:-:; M,.o.Dl:: B c---, ! GED' i'- f'BL~ ~-l RE~;:TI>:'I' - WORKERS COMPENSATION AND EMPLOYERS' LIABILITY .u.J...;"Y ;:'r<~':PR:ETI)R,PA.RT'ER/E)<ECUT :c OF,=! ::-:~RlM:::\,18F~ F~C:L U~iEc. '=, ~~E~::11~36~~~i'i~i~~;~s b9!Ov" OTHER i AWC1000855 i 03/0S/08 03/0S/09 E.C-,CJ-l')CCU.;:=EI'-J2E ___ ___ ;__$ , >U.iRb" TO, I ~ r-=.==-=-*--=-== [------.-----l-----__ ~ I ~ -. , ,1'...1 : :,Ri.l_II~ITd__ l:E-+____________ ~..:::~H ,"-~~~O 0 , Q.~2u___,. 1[" [iSEN3[ - iCe EtiPLO'E, I if 500 ,000 :;, C'SE"5E - ~,(~-, _;~LT-T$50a,000 I :, - I I I OESCRlPTIQr~ OF OF'ER.ATIONS I LOCATIONS f VEHICLES I E~CLWSIONS ,o.:D:O BY ENOORSEMENT I SPECIAL PR'JV',lm~s 2418 4~st street East Bradenton, FL 3420S CERTIFICATE HOLDER CANCELLATION SHOULO ANY OF THE ABO'!E OESC~18ED POLICIES eE CAtj':ELLED BEF'JR" THE E)<.PIR""ON DATE THEREOF THE ISSIJ~;(; IIJSURER WiLL E~;OEAVOR TO ~t~IL 30 DAYS ,\,I<I".E', CITY OF ZEPHRYHILLS BUILDING DEPAR~1ENT 5335 STH STREET ZEPHRYHILLS FL 33542 ",onCE TO T~E C"RTlFIC.~TE HOLDER ~AMEO TO THE LEFT, B"'T FAILURE T,J 0') 30 $~A"L :M~OSE N,:, OB.L1GA TIOt-J OR UA8:UT\' O~~"... KIN':; UPOf,J THE 1~,S'JReR. 'TS ':"CF.l'f;S ':'R ACORD 25 (2001/08) @ACORDCORPORATION 1988 Date: 5/1312C'08 03:3:: P~! Sender's Fax 10: SAY AROc "age 3 of 3 ,- IMPORTANT If the certificate helder is an ADDITI:::)t'JAL II'JSURED, the pollcy(ies) IT'ust be endorsee, A statement on this certificate does not confer ri;)hts to the certificate hOlcer in lieu of such endorsement(s) If SUBRCGATiOr,j IS W/:..jVED, 3ubject to the terms and conditions of the POliCY, certain policies n13f requh:: 8'i endorsement .A statement on chiS certificate does not c:)nrer rights to the certificate holder In lieu of such end'o;ser-,entis; DISCLAIMER The Celtific:ate of Insu:'an:::f:: on the 16ve'se side JT this form does I'ot constitute a oon'::a:t betweer the issuing Insurer:s; authOrized re:xesentative or prooucer, and the ce'tlficate holder, nor does it affrrmative:yor negatlvel'y' amend, extend or alter the cO'/erage afforded by the policies listed thereon ACORD 25 (2001/08) 5/13/2008 4:27 PM FROM: Fax Commercial Air TO: 9-1-813-780-0021 PAGE: 001 OF 001 ~ . ~ 2418 441.t Street East, Bradenton, Florida 34208 Ph 941-744-1272 Fax 941-746-9812 www.CommerciaIAirService.com D @D!lJrb IJJDffd ~&[Jl@]~ D[Jt]@a May 13, 2008 City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 Ph 813-780-0020 x3513 Fax 813-780-0021 Dear Jackie, Please accept this letter in lieu of an occupational license. Manatee County does not issue this license for state certified contractors. Thank You, Brett Allred CAC058586 Date: 5/1312008 04:12 PM Sender's Fax 10: BAYAR04 Page 2 of 3 ACORD. CERTIFICATE OF LIABILITY INSURANCE OP 10 AM I OA TE (MM/ODIYYYY) COMME-1 05/13/08 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Bay ~ea ~n~urance ~nc. HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 9067 Belcher Road ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Pinellas Park FL 33782 Phone: 727-544-8841 Fax: 727-544-8842 INSURERS AFFORDING COVERAGE NAlC # INSURED INSURER A Assoc" Xndustries Ins _ Service INSURER B Commercial Air and Applicance INSURER C 10105 Services ~nc. 2418 41st Street E INSURER 0 . Bradenton FL 34208 INSURER E COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITl1STANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCWENT WITl1 RESPECT TO WHICH Tl1IS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY Tl1E POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS LTR NSR[ TYPE OF INSURANCE POLICY NUMBER DATE (MMIDDNY) DATE (MM/ODNY) LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 I-- A ~ COMMERCIAL GENERAL LIABILITY LBA006134 02/08/08 02/08/09 PREMISES (E~~~~~~~ence) $ 50,000 f-- o CLAIMS MADE ~ OCCUR MED EXP (Anyone person) $ 5,000 PERSONAL & mv INJURY $ 1,000,000 I-- GENERAL AGGREGATE $ 2,000,000 I-- GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS - COMP'OP AGG $ 1,000,000 !xl n PRO- nLOC X POLICY JECT AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT I-- $ 500,000 ANY AUTO (Ea aCCident) I-- ALL OWNED AUTOS BODIL Y INJURY I-- $ C ~ SCHEDULED AUTOS 3383612 02/08/08 02/08/09 (Per person) HIRED AUTOS BODIL Y INJURY I-- (Per accident) $ NON-OWNED AUTOS I-- I-- PROPERTY DAMAGE $ (Per accidenl) GARAGE LIABILITY AUTO ONL Y - EA ACCIDENT $ R ANY AUTO OTHER THAN EA ACC $ AUTO ONL Y AGG $ EXCESSIUMBRELLA LIABILITY EACH OCCURRENCE $ tJ OCCUR D CLAIMS MADE AGGREGATE $ $ R DEDUCTIBLE $ RETENTION $ $ WORKERS COMPENSATION AND X !TC;R\t:MITS I IVER B EMPLOYERS' LIABILITY AWC1000855 03/08/08 03/08/09 $ 500,000 ANY PROPRIETORIPARTNERlEXECUTIVE E.L EACH ACCIDENT OFFICERlMEMBER EXCLUDED? E.L DISEASE - EA EMPLOYEE $ 500,000 If yes, describe under E.L DISEASE - POLICY LIMIT $ 500,000 SPECIAL PROVISIONS below OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PROVISIONS 2418 41st Street East Bradenton, FL 34208 CERTIFICATE HOLDER CANCELLATION SHOULD PJolY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN CITY OF ZEPHRYHILLS BUILDING DEPARTMENT 5335 8TH STREET ZEPHRYHILLS FL 33542 NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR ACORD 25 (2001/08) @)ACORDCORPORATION1988 P.Ol/Ol TRANSACTION REPORT MAY/14/2007/MON 02:48 PM RECEIVER 819413590709 TYPE/NOTE OK ...................... ..................... ............... .. .................. . .. -..... ... .... ':Ci1y ,ofZep~yi~lls: . Building Department Phone: (813)~780-0020 Fax: (813)-780-0021 :(,:;.1'~i~.;:JJii\i:~Pi~S;l::~i.:;;!i~~;;f!:!:I~;:.~:',~;;'i :~~'i;;:;'~". '\~(i;'~~f'~' '~~:~:~\ ,,~,\ ,,"' \~1'" .~~. ~.~ ~;, ---~-----------~-----------------------_._------------------~----, TO: CommericalAir FROM: Jackie : I FAX#: : I . I I , I I I I I I , I I I J I I I I I I I I I I ., I I . I I I I I J I I I I I I I I . I I I I . I I , I 1______-----------------------------------------------______~_____~ FAX#:941-359-0709 . I>i\TE: 5-13-08 # OF PAGES. including cover sheet: 2 MESSi\GE: , Attached with this cover sheet is the requirement to get your company registered ~ith us in the City of Zephyrhills; Youmay faxa1l this information back to our office no fee is involved beCause your company is state certified. After I have your company registered I will then fax over the permit application for the I Napa project and have your company to sign on the permit. Please fax everything back. Thanks Jackie SG3 I DIVISION 15 HVAC INC - · ~ I L. '-'r r &..u~..... 9413590709 >> 813 780 0021 P 2/2 DEPARTMENT OF B SINESS AND PROFESSIONAL REGULATION lCONSTRUCfIOH I USIRY LICENSI~ BOARD (850) .87-1395 ~",;.~. iXt~~EMONR B STR~fT32399_0783 COMMBRC~L AZR . 2419 41ST STRBET E BRADENTON LIANe!: SERVICK :IRC FL 34208 . STATE OF FI.ORlDA AC# 33 Lj 5 [J.5 9 , ~BPARTMBlrr OF Bt1SIITB'SS AND" . PROPESSIONAL RBGULATIOlll . QB0019207 08/17/07 '010D96517 QUALIFIBD BUSIN2SS ORGAHIZATION CONM8~CIAL AIR . APPLIANCE SERVIC (ROT A LICENSE TO PIRFORH WORK. ALLOWS COMPANY TO DO BUSINESS IF IT HAS A LICBRSED QOALIFIBR.) IS QVAL:IFll:D _d.~ tb. Pl:'OII":i..io". oj! c:b."89 r.I. kpl~"'loa ..,., AUG 31. 200' L1I10n 7D1U7 DETACH HERE ACI3348059 STATE OF FLORIDA BOSINESS AND PROFBSSIONAL REGULATION CT.ION J:NDOSTRY LICPlNSING BOARD SEQ#L070817014S7 NBR 08 17 2007 070096517 80019 The BUSINESS ORGANIZATXON Named below IS gUALIFIED Under the provisions of Cb Expiration date: AUG 31, 2 (THIS IS NOT A L:tCENSE TO COMPANY TO DO BUSINE$S'ONL .." COMMERCIAL AIR &. APPLIANC2 2418 41ST St'RJU:T E,:, BRADENTONYL 34 ter 499 FS. 9 REORM WORK. THIS ALLOWS XF IT HAS A QUALIFIER.) ERVJ:CE me 8 CHARLIE CRIST r:ynv...~W"'D 2008-05-13 14:37 727 896 3654 BOLLY BENSON C"'a"'~ 1 City of Zephyrhills: Building Department Phone: (813)-780-0020 Fax: (813)-780-0021 -----------------------------------------------------------------, : TO: Commerica1 Air FROM: Jackie : ! I : FAX #:941-359-0709 FAX #: : 1 I : DATE: 5-13-08 # OF PAGES including cover sheet: 2 : I I I I ! ! I I : MESSAGE: : I I : Attached with this cover sheet is the requirement to get your company registered with us in : I I : the City of Zephyrhills. : I I : You may fax all this information back to our office no fee is involved because your : 1 1 : company is state certified. : 1 I : After I have your company registered I will then fax over the permit application for the : I I : Napa project and have your company to sign on the permit. Please fax everything back. : I I I I I I I I I Thanks Jackie I I I I I : I I I I I I I 1 I 1 I I I I I I ! I I 1 I 1 I I I I I I I I I I I 1 I '______-----------------------------------------------------------~ Date: 5/13/2008 04:12 PM Fax From: Pages: Date: Subject: Sender's Fax ID: BAYAR04 Angelica Metz 3 5/131200803:15:43 PM CERTIFICATE OF INSURANCE To: Fax: Phone: Page 1 of3 Phone: (727) 544-8841 Fax: (727) 828-0529 (813) 780-0021 ( ) - Message: 2008-05-13 14:50 DIVISION 15 HVAC INC 9413590709 >> 813780 0021 ~...... P 1/2 ~ A-t\- ~ -:s-~. l-c/ r-\<,,-'1 [.-S \Ju 'l \\ \Qt:/ cAo\ 0'-:' '-"d \-\ d\V ~. \<~ e . C\*- ~ vJ~ N~ppc~ S -\u\'L/ I \ (/&..'-S 'C/ \=' Co/ lfV\v ~I o>r f'<=i)\lrLY\;~v\''t.~ ~ \\~~~ IOV~ ~~'^^-- q 4 f- 7 <f~-/& z ~11e 40 (r-ste b 5126 8 (MIpt .___-~-... .... ..__......_.r..__. RDORNS SYSTEMS. 121113 North u.s. 30t TIM"'''' PL338a 813-916-H83 FAx 113-_6-8719 . Fax ~ -BagoI IJIaQ 813-78().O(Yl1 ....... 813-78OOO'lO J1t; l8Y8 st~ ,.... ~ In~ ti.l.tf,pt; L' e~,,- ..... __,~~ .S::-/3-d:; .., . cc: . " C U...... 0 For .._~ . C ....... c::......a.__: CJ.... .....,. C .....lIIIqde ..~ pr..- register. us and, pt.... send me "the sign on InlionnaIiuI'I for'lhe.'N11P8 Jab bY KennedY . eontraotors. Thankii You ~ 9",:",~. "OW,.~ ~'''6.,dvu.... La~ ~&r.l -13 . Sf3- 7 80 - ()~J ~ ~V\~$ \S ~\<? ~ --tv do as -&vr . ~~QfV'J'-\~ ~ 7? (lLL ~S tu.e ~e/'t9 :3e'1d s ~r,;jo~ ~ lGOO-08L-EI8 'ON XVi s 9NI~OO~ 3l8~a~o~~~ 6LL99B6EtB 6e:L~ ai9t/Et/9a rOO'd 2:0/10 39~d "~IalIna Sl11HaAHd3Z NY 90:01 NONILOOZ/v111VN 6LL9986E18 99:60 800Z:/E1/90 Affordable Roofing Systems, Inc. May 13, 2008 To whom it May Concern: IJames Richard Mellette PresidentlQualifie! of Affordable Roofing Systems CCC1326772, authorize Stacy Mellette to be a signer for all Permitting purposes. Her Driver's License Number is M430785639670. Thank You, James Richard Mellette OwnerlPresident The foregoing instrument was acknowledge.d b~ ore me this J 3 day o~ 2008 by Y)UJ ho is personally known to me. ~\\\\\''''IIII11'"" ~,~ ~ MOItQ.~-_" ~ ~~\"".\~'~"~ ~ .~--~, I ..,.~~ !1', .!'(}-"~'. 0:. ~ . ~ ~. .. i*: .... :*~ ::.\ ..:: ~ ~.. #O03735221::!l:":: ;,; ~ . ,#,:... S) ~ % ~.'~~l/g/,tSl~.'~-f ~ r~ ~ ...... ~,,- ~ "-''''J: 19l1C ..,.~~ \J' ...,,~ '/11 . ~, ", 1/'''"''''11''\' 1-888-391-ROOF * (813) 9866683 * Fax (813) 986 6779 License No. cee 1326722 t'13/G13 39'itd S 9NI~OO~ 318'ita~O~~'it 5LL99B5E!8 5E:L13 B1313G/E!/SB Ma~ 12 2008 2:08PM HP LASERJET FA)( 8138651198 p.2 ACORD CERTIFICATE OF LIABILITY INSURANCE I.M1&~ JJ// 0511212008 ~ THIS CERTIFICATE IS 1SSUI!D AS A MATTliR OF INFOlUlAnoN Ptofeeslon.. Insurance SlMVleeslnc ONLY AND COJFeRl NO RIGHTS UPON TtE ceRTIFICATE HOLDER. THIS C;EImFICATe DOES l'O1' AlIENO, IiXTEND OR 383t W. Hutnphrey sa. AL TEA THE COVERAGE AflFOR'DED BY THE POLIQES BELOW. Tarn~ FL 33814 INSURlRa AFPORDltG COVERAGE MAlC" IIIllUIIBD Alfordable Roofing Services. Inc. I..."".RA: NORrH POINTIii INSURANCE 12573 N. us HIghway 301 1......._., IIlIRST NATIONAL INSURANCE I INIIUl'I!R c: MICHIGAN CONSTAucnON Thonoto..... FL 33612 INSUi1I!It D: lNS:lJfl.... e: COVERAGES 'niE POl.IOlES OF INSUAANCE USTSl BELOW HAlJE iIeH IS6\'n:D TO THE INSUIU!D NAMED ABOVE FOR 'THE POUCY PROO INDICATSD. NQTWITt4$TAHDlNG fIM'( RIQUIREMENT, 1'!FtM OR CONDITION OF MY CON'TMCi ()Ii. OTHP DOCUMENT WITH RESPeCT TO WHIC" THIS cemFlCATE MAV ae ISSUED OR Ml\Y l"ERT...... THe IHsuFWtCE AFFORDED eN 114E POLICIES DESCRlBEC rtEREIIl IS SUBJeOT TO /lU. THe: TERMS. SCCLUSION8 AfoIO CONOI11OHS OF SUCH f'ClL,JC1E8- AGQR!Go\TE UMITS SHOWN MAY HAVli BEeN REOUcED IIY PAlO CLA_. 11_ ..-..nv t ODO 000 A CIAl. GIIiHElW.~B1urt %0841188&2 0110812OO7 0810112001 tOO 000 CLAIMaMADE X OCCUlt c50DO . '.000 000 000 000 2 000.000 01CH78787'10 0411712_ COUIIlNB> lllHGLE UNIT" . '00.000 B 04/1712C1n (Ii. Mddaftl) 8OO......INJUR't" J, t"- ,...., ".lUiC AUTOS IlCOIL Y I NJU..... (Pet -eeldonIl $ NONoOWIII;Il AUT05 . __R8IlO....TlONAIlD C ~u.uTt AN'( PIlOP"liTOIWAATIIEREl(E~ Ol'l'lCERlNEMIIEA lllCCLUO&O? If d.,.. U1dW cmlE WC100-0012101-2G01A D8IOlll2OO7 08lDll2G08 ~NIUT't DCCUIIl U CtA" WIDE IlIDUCTllILI! DI!SCIlIJ'1IOlIII? OfIIIIlATlO.' LDCATlDIII' vliltlCLM, El(GI.UIIOlI8Ml1lED IYMDORO-llT' IPC~ ~ fa~ to~ 813-88"779 C1ty of Z8phyl'hlll. 53351th Stnlet CANCELlATION IHDUUl/lll'fOP,..,.owaaIlQllMED ,~_CAIICILLEO.1JIGllIl1Hl1JIIIIRA11OII a,.~ .,....0fI. .... ..... __ wu. IitlDIAVUll to MAIL .J.JL. IIA'" VIlIUTT1II 1l0l1Cll '"' TIE CWJmPIGA.,.ttol.DI!!R~1VTIleU", 8UT~1Q DO aa.w.L Iwoae IlCI a8UQAllQa 0lIl .........., Of" /tH'I K..a UPOIIlIIE ...,.... ITS ,..." OR ..,."'\'IVa ~__A'IIft cIIF> OAcoRD CORPORATION 1_ CERTlFIGATE HOLDER zephyrillll.. FL 3361Z ACORO 21 (2001/08) Pel/Eel 39'i1d S 9NI~OO~ 318'i1a~~~'i1 6LL9986E!8 6E:L0 8elell/E!/9el ~c# 2 G 2 t: ;J. ) ;~) STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY .LICENSING BOARD SEQ#X.06061.600601 DATE .~ .06/16/2006 ~~=::7:R :~ ...=- The ROOFING CONTRACTOR Named belo~ IS CERTIFIED under' the provis~ong of Chapter 489 ~S_ Expiration date: AUG 31, 2008 MEL:LETTE, JAMES RIc:EIARD JR AFFORDABLE ROOFING SYSTEMS INC 12573 N US 30l THONOTOSASSA FL 33592 JE:B :BUSH GOVERNOR DISPLAY AS REQUIRED BY LAW SIMONE MARS TILLER SECRETARY 1:10/1:10 39\i'd S 9NI~OO~ 318\i'a~~~\i' 6LL9986E18 6E:L0 800~/El/S0 FROM HCTC 2506 N. FALKENBURG RD. (MON)OCT 15 2007 20:521ST. 20:52/No. 6828812298 P HIU-SBOROUGH ~N1"Y BUSINESS TAX RENEWAL INSTRucnoNS cnapt.r 205.0535 (5) FlOrid8 ~ requi.... one of tne following: FEDERAl EMPLOYER IDENTIFICATION NUMBER OR SOCIAL SECURITY NUMBER 1. SIGN and return .nII.. farm In eneloeed envelo.... yOuf'v.ld..... ...._. TIIX NCeipt will ... retumecl10 you. 2. Busin." Tax rec*pts eJCPire midnight. September 30th. Faa",r. tQ displey II valid Business Tax receipt after September 30th is a violation of Hlhborough County Ordinana! ~. u amended by 02-5. ~~~~ MAKE CHECK PA YAILE TO: DOUG BELDEN, TAX COLLECTOR POBOx 112120 TAMPA. FL 33872...20 2007.2008 HllLSBOROUGH C NTY BUSINESS TAX RECEIPT EXPIRES 9~30..2008 ,OUC) NO. rACI.mEIICR~ jIl--' ....--. .. ol"trATS 011--.0- 1J I 169790 Ii. ~.,e TAA SUR~QE 40.00 18.00 ace. ODE 090,000 - MAlUNG ~S& 12G7-3 N301 HW'fC' _' c '~,~_. \'...... . T;H~~~.~3592" ,,:. \ ~~ t 'S .,:2 ai.eu:eT.re J,...es a:uciwtD'JR . -,.f! \... l~: :' ..~ ~FFOA0A'8LE ROOFlNG $YmMS'1NC '.' --.. 12573 N 301 HWV THONOTQSASSA FL 33592 BUSINesS LOCATION BUSINESS TAX - DOUG BELDBI. TAX cou.eCTOR 81....... '''III!SCGIIES A TAX llI'CEPf WHl!It VALlMTED. __U"PAID~_"'...xro_ IHlIU$_,,~.QROCQUPA"ll"8I'EGfl!D- *** PAID *** 2007.2008 HILLSBOROUGH COUNTY BUSINESS TAX NOTICE l'AC&JT&llll-- 011- 011-18 01 r--- 111 H. M8TE TIoll $URCttAAGe 40.00 18.00 MAKE CHECK PAYABLE TO: OOUC Bll.DI!N, TAX CDLLEC1'OIt 1'0'" 17J11O TAlI"" PL uen.-zo AUG 1-8EPT so ~1_T.Qt 58.001 DEuNQUliNT0CT31 2007" _0__' 83.!01 D~LINQUEttTNOV . ZG01....I-lY- _.701 DeuNQUENT DEe 31 2IDT ..1....",*MI'f ouol DEUNQUENT JAM 31 2001 "'1-""MIIlIf'I n.5Ol PAY AMOUNT IN ....Eft Bbx 8USlNU(l ~0CA"r1CIllI ..: ", 12i1,3 N.3011"IW~\ . . .; 1.J'IO,!OT~S~2 .... ......., ,. ..:~_. ~JAMEs RIOHAAD JA ~ . - ., AFPORI:lA8LE ROOFING SYSTEMS INe 12673 N 30. HWY . THONOTOSASSA FL 33592 SICN X ~ MIlIUNG AIJOAI5$$ III __"FOR"J1E_~ *** PAID *-* 10/10 39'\1d S 9NI~OO~ 318'\1a~O~~'\1 6LL9986E18 1E:60 800G/E1/~0 ROOFINS SYSTEMS 12573 North U.S. 301 Thonotosassa, FL 33592 813-98~6683 FAX 813-986-6719 Fax ~ ;ref. Jackie Boges Fax: 813-780-0021 Phon8: 813-780-0020 70 j!I!oftr' Leya Blison Pager. ..t/ {'It!. (utiJ1;5' e~". Date: May 13, 2006~ s:- /3-cJf5 .. cc: D UrglHlt 0 For IIeVitM 0 ....... Comment 0 PI.... Reply CJ ...... R8cycle . Comment.: Please register us and please send me the sign on infonnation for the Napa job by Kennedy Contractors. Thanks You ~: (1'- (YV-R- ~~ -:JA. \{' & ck '--10 -0 ~ S'1r~~-Ul/~__ La ~W ' 8'3- 7 80 - OO-Z} ~ P0/Hl 39'ii'd S 9NI~OO~ 3l8'ii'a~O~~'ii' 6LL9986E!8 6E:L0 800l/E!/90 From:Sandy petrunger FaxID:561-694-6521 Page 1 of3 Date:412212008 12:12 PM Page:1 of3 CELEDINAS INSURANCE GROUP Established 1959 FACSIMILE TRANSMITTAL SHEET To: City of Zephyrhills Company: Fax: (813) 780-0021 Phone: (813) 780-0000 Subject: Certificate -City of Zephyrhills From: Sandy Petrunger Date: 4/22/2008 11 :01 :51 AM Pages: 3 Phone: (561) 514-5660 Fax: (561) 721-0540 spetrunger@celedinas.com Message: Confidential Infonnation in ~is facsimile is confidential and intended for use by the individual or entity named above. If you received this telecopy in error, please immediately telephone us and return the original via US Postal Service From:Sandy Petrunger FaxID:561-694-6521 Page 2 of 3 Date:412212008 12: 12 PM Page:2 of 3 ACORD. CERTIFICATE OF LIABILITY INSURANCE OP 10 SP I DATE (MMlDDNYYY) . LEYVA-l 04/22/08 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Celedinas Insurance Group -PSG HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 4283 Northlake Blvd. ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. pa1m Beach Gardens FL 33410 Phone: 561-622-2550 Fax: 561-721-0540 INSURERS AFFORDING COVERAGE NAIC# INSURED INSURER A Nationwide Mutual Ins Co 23787 INSURER B Bridgefield. hployeEs Ins. eo 10701 Leyva Plumbing Services, Inc. INSURER C Abner L~a 484 SW oltair Terrace INSURER 0 Port st. Lucie FL 34984 INSURER E COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOlWlTHSTANDING ANY REQUIREMEIIfT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMEIIfT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS LTR NSR[ TYPE OF INSURANCE POLICY NUMBER DATe (MM/ODNY) DATE (MM/ODNYI LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 - A X COMMERCIAL GENERAL LIABILITY 77AC8180393001 06/16/07 06/16/08 PREMISES (Ea occurence) $ 100,000 - ~ CLAIMS MADE ~ OCCUR - MED EXP (Anyone person) $ 5,000 PERSONAL & KJV INJURY $ 1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS - COMP/OP AGG $1,000,000 I n PRO- nLOC POLICY JECT AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT - $ ANY AUTO (Ea aCCIdent) - ALL OWNED AUTOS BODILY INJURY - $ SCHEDULED AUTOS (Per person) - HIRED AUTOS BODILY INJURY - $ NON-OWNED AUTOS (Per accident) - PROPERTY DAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY - EA ACCIDEIIfT $ ==1 ANY AUTO OTHER THAN EA ACC $ AUTO ONLY AGG $ EXCESSIUMBRELLA LIABILITY EACH OCCURRENCE $ ~ OCCUR D CLAIMS MADE AGGREGATE $ $ ==1IDEDUCTIBLE $ RETEIlfTION $ $ WORKERS COMPENSATION AND X I TORY LIMITS I IVER B EMPLOYERS' LIABILITY 19605453 03/30/08 03/30/09 ANY PROPRIETORlPAATNERlEXECUTIVE EL. EACH ACCIDENT $ 100,000 OFF ICERlMEMBER EXCLUOED? EL DISEASE - EA EMPLOYEE $ 100,000 If yes, describe under $ 500,000 SPECIAL PROVISIONS below EL DISEASE - POLICY LIMIT OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES J EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PROVISIONS CERTIFICATE HOLDER CANCELLATION ZEPHYRI SHOULD !>JoN OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL XX DAYS WRITTEN - NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT. BUT FAILURE TO DO SO SHALL City of zephyrhills IMPOSE NO OBLIGATION OR LIABILITY OF !>JoN KIND UPON THE INSURER, ITS AGENTS OR 5335 8th st REPRESENTATIVES. Zephyrhills FL 33542 AUT ESENTATIVE .A/UI - . '" <.AT- ACORD 25 (2001/08) @ACORDCORPORATION1988 From:Sandy Petrunger FaxID:561-694-6521 Page 3 of 3 Date:412212008 12:12 PM Page:3 of3 IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER The Certificate of Insurance on the reverse side of this form does not constitute a contract between the issuing insurer{s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. ACORD 25 (2001/08) 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALLAS NEW JERSEY ST. PETERSBURG Letter of Transmittal December 6, 2007 To Ms. Karen Miller City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 813.780.0020 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 From Karla J. Sherrell We are sending you the following enclosures via Air Express - Standard for your use: Building Permit Review Copies/Sets Date Description 3 8-1/2x11 Site Plan Original Copy of Letter of Authorization for Agent Message The above referenced site plan is being submitted per your request. The referenced original letter is being submitted for your record. If there is any additional information that you may need or if there are any questions or comments that you may have, please feel free to contact me at your convenience. Thanks! If enclosures are not as noted, please contact sender Copies 01 Transmittal 02.06,06 P:12007\200702080\999 General Correspondence\200702080 Transmittal from Karla J. Sherrell to Karen Miller at the City of Zephyrhills 2007-12-07A.doc Florida Building Code Online Page I of3 .. Product Approval USER: Public User Product Approval Menu> Product or Application Search> Application List> Application Detail FL # Application Type Code Version Application Status Comments Archived FL5485 New 2004 Approved Product Manufacturer Address/Phone/Email YKK AP America 332 Firetower Road Dublin, GA 31021 (478) 277-2549 chrismoody@ykk-api.com Authorized Signature Chris Moody chrismoody@ykk-api,com Technical Representative Address/Phone/Email Jose I Archila 332 Firetower Road Dublin, GA 31021 josearch ila@ykk-api,com Quality Assurance Representative Address/Phone/Email Category Subcategory Panel Walls Curtain Walls Compliance Method Test Report Testing Lab Quality Assurance Entity Costruction Research Laboratory Architectural Testing, Inc, http://www.floridabuilding.org/pr/pr_app _ dt1.aspx?param=wGEVXQwtDqsqFh V2n%2fq3... 12/4/2007 Florida Building Code Online Page 2 of3 Validated By Architectural Testing, Inc Certificate of Independence Referenced Standard and Year (of Standard) Standard AAMA 501 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B Date Submitted Date Validated Date Pending FBC Approval Date Approved 09/23/2005 12/01/2005 12/02/2005 12/07/2005 Summary of Products FL # Model, Number or Nam 15485.1 IYCW 750 Limits of Use (See Other) Approved for use in HVHZ: Approved for use outside HVHZ: Impact Resistant: Design Pressure: +/- Other: Design Pressure= +/- 55 psf. Not for use in HVHZ. P.E, must provide calculations on anchors. cription Aluminum Curtain Wall Installation Instruction PTID 5485 I ycw7500g Verified By: Test Reports PTID 5485 T CRL Indep PTID 5485 T YCW7500f PTID 5485 T YCW750QI Back I I Next DCA Mministratioo Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 @ 2000-2005 The State of Florida. All rights reserved. CODvriaht and Disci. Product Approval Accepts: ~r..;iIiiil~. ~~~ http://www.floridabuilding.org/pr/pr_app _ dt1.aspx?param=wGEVXQwtDqsqFh V2n%2fq3... 12/4/2007 9 YKK a~ YCW 750 OG Outside Glazed Curtain Wall System / Installation Manual @2004 YKK AP America Inc. is a subsidiary of G YKK Corporation of America. YCW 750 OS Curtain Wall System YKK aR TABLE OF CONTENTS Installation Notes ........................................ Page ii PARTS DESCRIPTION YCW 750 OG Framing Members . . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 1 & 2 YCW 750 OG Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . " Page 3 to 5 FRAME FABRICATION Anchoring MethodslFraming Types .......................... Fabricate Vertical Mullions .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using Alternate Reinforcing ................................ Attach Shear Blocks/Clips for Horizontals ..................... Attach "J" Anchors ....................................... Fabricate Horizontal Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fabricate Pressure Plates ................................. Fabricate Face Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FRAME INSTALLATION Typical Vertical Splice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Continuous Perimeter Anchor ......................... JambNertical Installation With Perimeter Anchors . . . . . . . . . . . . . . . JambNertical Installation With Mullion End Anchors .... . . . . . . . . . Install Wind Load 1 Dead Load Anchors . . . . . . . . . . . . . . . . . . . . . . . Attach Horizontal Members ................................ Apply Perimeter Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Joint Plugs ........................................ GLAZING Install Glazing Adaptors ................................... Install Interior Glazing Gaskets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Setting & Side Blocks ............................... Install Exterior Glazing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Glass ............................................ Pressure Plate Layout and Assembly. . . . . . . . . . . . . . . . . . . . . . . . . Install Exterior Face Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6 & 7 Page 8 & 9 Page 10 Page 11 Page 12 Page 13 to 15 Page 16 Page 17 Page 18 & 19 Page 20 Page 21 Page 22 Page 23 & 24 Page 25 to 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 33 Page 34 Page 35 Effective Date: July 15, 2004 Page-i YKK a~ YCW 750 OG Curtain Wall System Installation Notes 1. Do not drop, roll or drag boxes of aluminum framing. Move and stack boxes with proper support to prevent distortion. If fork lifts are used be especially careful about striking the boxes when lifting or moving. 2. Store in a dry, out of the way area. If rain exposure, condensation or any water contact is likely, then all packaging material should be removed. Wet packaging materials will discolor and may stain aluminum finishes and paints. 3. All materials should be checked for quality and quantity upon receipt, YKK must be notified immediately of any discrepancies in shipment. Check to make sure that you have the required shims, sealants, supplies and tools necessary for the installation. 4. Carefully check the openings and surrounding conditions that will receive your material. Remember, if the construction is not per the construction documents, it is your responsibility to notify the general contractor in writing. Any discrepancies must be brought to the general contractor's attention before you proceed with the installation. 5. Gather your shop drawings, materials, packing list, and this installation manual. Carefully review parts location, the sequence it goes therein, when you glaze it and how you seal it. Installation instructions are of a general nature and may not cover every condition you will encounter. The shOp drawings and/or installation manuals were prepared specifically for the product. 6. Any material substitutions must be of equal or greater quality. 7. Make certain that material samples have been sent for compatibility testing for all manufacturer's sealants involved. Make certain sealants have been installed in strict accordance with the manufacturer's recommendations and specifications. 8. Remember to isolate, in an approved manner, all aluminum from uncured masonry or other incompatible materials. 9. System-to-structure fasteners are not supplied by YKK. Fasteners called out on shop drawings are to indicate minimum sizes for design loading. 10. If any questions arise concerning YKK products or their installation, contact YKK AP for clarification before proceeding. 11. YKK storefront and/or curtain wall framing is typically completed before drywall, flooring and other products which may still be in process. Take the extra time to wrap and protect the work that you have proudly produced, because no one else will. 12. Cutting tolerances are plus zero, minus one thirty second unless otherwise noted. 13. Check our website, www.ykkap.com. for the latest installation manual update prior to commencing work. Effective Date: July 15, 2004 Page-ii YCW 750 OS Curtain Wall System YKK a~ FRAMING MEMBERS ~~ JI Vertical! Horizontal Horizontal Cover E9-1256 2-1/2" x 5-1/4" E9-1246 t , For 5-1/4" Back Horizontals For 1/4" Glazing 0 Vertical! Horizontal Horizontal Cover E9-1038 2-1/2" x 3-3/4" E9-1250 t \ For 3-3/4" Back Horizontals For 1/4" Glazing ~ ~ Horizontal Pressure Plate Two Piece E9-1258 ~ E9-1216 with PVC Isolator AS-1216 2-1/2" x 5-1/4" Punched 9" O.C. For 1/4" Glazing Horizontal Perimeter Pressure Plate R Two Piece E9-1259 ~ For 1/4" Glazing AS-3572 2-1/2" x 3-3/4" E9-3572 with PVC Isolator For 1/4" Glazing Punched 9" a.c. Perimeter Pressure Plate ~ II Vertical! Horizontal k For 1" Glazing AS-3569 2-1/2" x 5-1/4" E9-1215 E9-3569 with PVC Isolator For 1" Glazing Punched 9" a.c. Pressure Plate ~ jl Vertical! Horizontal r, For Deep Covers AS-3574 2-1/2" x 5-1/4" E9-1225 E9-3574 with PVC Isolator For 1" Glazing Punched 9" a.c. Perimeter Pressure Plate ~~I Vertical I Horizontal ~ For Deep Covers, 1" Glazing AS-3576 2-1/2" x 3-3/4" E9-1235 E9-3576 with PVC Isolator For 1" Glazing Punched 9" a.c. ~~I Vertical I Horizontal ~ 1 Face Cover E9-1206 2-1/2" x 3-3/4" E9-3537 2-1/2 x 3/4" For 1" Glazing ~ II Vertical! U Horizontal Face Cover E9-1229 2-1/2" x 6-3/4" E9-1242 2-1/2 x 1-3/4" For 1" Glazing af 'J Horizontal D Face Cover apen Back E9-1219 2-1/2" x 5-1/4" E9-1255 2-1/2" x 2-3/8" For 1" Glazing ~ II Horizontal [ Horizontal Face Cover apen Back E9-1257 E9-1207 "J 2-1/2" x 3-3/4" 11/16" x 2-1/2" For 1" Glazing . Splay mullions and other face covers are available, contact YKK AP. Effective Date: July 15, 2004 Page-1 YKK SR YCW 750 OG Curtain Wall System FRAMING MEMBERS 0 Bull Nose Face Cover L 900 Outside Corner 2-1/2" x 2" E9-1293 Face Cover E9-1228 For 1" Glazing =:J Glazing Adaptor L 900 Outside Corner For 1/4" glazing E9-1220 Face Cover E9-1238 For 1/4" Glazing ~ Glazing Adaptor E9-1232 ~ Interior Cover Base E9-1280 For 1/2" Glazing Use with E9-1281 l Flush Pocket Filler M Interior Cover For 1" glazing E9-1253 For 90' Outside Corner E9-1281 Use with E9-1280 Perimeter Anchor c:;:J Single Acting ~ E9-1248 Transom Bar For 1/4" Glazing Elastomer Weathering AS-0402 E2-0051 Included ~ Perimeter Anchor 5 Standard Door Jamb For 1" Glazing E9-1223 For 1/4" Glazing E9-1224 Use with AS-0417 U Perimeter Channel 5 Standard Door Jamb For 1" Glazing E9-1231 For 1" Glazing E9-3513 Use with AS-0417 ~ 900 Outside Corner 5 Adaptor E9-1236 Heavy Duty Door Jamb E9-3531 For 1/4" Glazing Use with AS-0441 y 900 Outside Corner -r Heavy Duty Door Stop Adaptor E9-1226 Elastomer Weathering AS-0441 For 1" Glazing E2-0051 Included Use with E9-3531 ~ 900 Outside Corner Snap-In Door Stop Pressure Plate AS-1237 ~ Elastomer Weathering with PVC Isolator, punched E2-0051 Included AS-0417 9" O.C., For 1/4" Glazing Use with E9-1224 ~ 900 Outside Corner Pressure Plate AS-1227 with PVC Isolator, punched 9" O.C., For 1" Glazing Effective Date: July 15, 2004 Page-2 YCW 750 OG Curtain Wall System YKK a~ ACCESSORIES ~ Standard Shear Block Shear Block for 900 For E9-1235, E9-1250, E1-3503 n ~n4n "- Outside Corner E1-3503A .... & E9-3537, 3.125" Long , For E9-1235, E9-1250, & E9-3537, 5.794" Long ~ Standard Shear Block Shear Block for 900 For E9-1215, E9-1225, E1-3504 n ~- __+n__ " Outside Corner E1-3504A , E9-1246, 4.375" Long , For E9-1215, E9-1225, E9-1246, 7.562" Long ~ Standard Shear Block Shear Block for 900 E1-3506 n ~, mn : nn_ " Outside Corner For E9-1242, 6.000" Long , For E9-1242 E1-3506A 9.860" Long ~ "J" Anchor ~ Shear Clip for 900 For E9-1235, E9-1250, E1-3501 Outside Corner E1-1213A & E9-3537, 3.125" Long For E9-1255 & E9-1258 E1-1213B 7.135" Long ~ "J" Anchor Shear Clip for 900 For E9-1215, E9-1225, E1-3502 ~ Outside Corner E1-1214A E9-1246, 4.375" Long For E9-1257 & E9-1259 E1-1214B 5.369" Long ~ "J" Anchor r ~ "J" Anchor for 900 For E9-1242, 6.000" Long E1-3505 Outside Corner (RH) E1-3501A For E9-1235, E9-1250, & E9-3537, 5.669" Long ~ Shear Block (For E-Slot) ~1 "J" Anchor for 900 For E9-1235, E9-1250, E1-1206 Outside Corner (LH) E1-3501B & E9-3537, 3.125" Long For E9-1235, E9-1250, & E9-3537, 5.669" Long ~ Shear Block (For E-Slot) r 'Z_m_'--m"" "J" Anchor for 900 For E9-1215, E9-1225, E1-1200 " , " Outside Corner (RH) E1-3502A E9-1246, 4.375" Long " " For E9-1215, E9-1225, E9-1246, 7.437" Long ~ "J" Anchor for 900 ~ Shear Block (For E-Slot) E1-1236 , / _m<__ _,~ 1 Outside Corner (LH) E1-3502B For E9-1242, 6.000" Long / / ~ / / For E9-1215, E9-1225, E9-1246, 7.437" Long Shear Clip r -+_m____4 --- "J" Anchor for 900 ~ For E9-1257 & E9-1259 E1-1214 '" - -"" Outside Cor. (RH) E1-3505A 2.736" Long " " For E9-1242 9.735" Long ~ Shear Clip rm-- >_m___+ 1 "J" Anchor for 900 For E9-1255 & E9-1258 E1-1213 / / Outside Cor. (LH) E1-3505B 3.986" Long / / For E9-1242 9.735" Long 0 Mullion Splice Sleeve For E9-1235, E9-1250 E1-1212 & E9-3537 Effective Date: July 15, 2004 Page-3 YKK a~ YCW 750 OG Curtain 'Nail System ACCESSORIES 11 I) Mullion Splice Sleeve ~ Mullion End Cap for For E9-1215, E9-1225 E1-1201 900 Outside Corner E1-3519 & E9-1246 For 1/4" Glazing (( (( Mullion Splice Sleeve ~ ~ Mullion End Cap for For E9-1242 E1-1299 900 Outside Corner E1-3520 For 1" Glazing L Mullion "1" Anchor r:J Face Cover For E9-1235, E9-1250, E1-1207 Splice Sleeve E1-1202 & E9-3537, 3.462" Long For E9-1206 L Mullion "1" Anchor :r: Face Cover For E9-1215 E1-1208 Splice Sleeve E1-1203 4.866" Long For E9-1219 L Mullion "1" Anchor [[] Wind Load Anchor E1-1204* For E9-1225 & E9-1246 E1-1209 Steel with Zinc Oxide Paint Project Refer to Shop Drawings 4.960" Long for Anchor Dimensions Specific ~ Mullion "1" Anchor [fIJ Dead Load Anchor E1-1205* For E9-1242 E1-1238 Steel with Zinc Oxide Paint Project Refer to Shop Drawings 6.453" Long for Anchor Dimensions Specific U Mullion "F" Anchor 0 Reinforcing Steel For E9-1235, E9-1250 E1-1232 2" x 4" x 1/4" E1-0162 For 5-1/4" Sack Verticals & E9-3537, 3.462" Long Steel with Zinc Oxide Paint U Mullion "F" Anchor 0 Steel Reinforcement For E9-1215 E1-1233 2" x 4-112" x 1/4" E1-0154 For 5-1/4" Back Verticals 4.866" Long Steel with Zinc Oxide Paint U Mullion "F" Anchor ~ Setting Block For E9-1225 & E9-1246 E1-1231 For 1/4" Glazing E2-0112 4.960" Long EPDM with Pressure Sensitive Adhesive U Mullion "F" Anchor Side Block For E9-1242 E1-1240 ~ For 1/4" Glazing E2-0113 6.453" Long EPDM with Pressure Sensitive Adhesive ~ Temporary Glass ~ Setting Block Retainer E1-1294 For 1" Glazing E2-0104 2" Long EPDM with Pressure Sensitive Adhesive Mullion End Cap ~ Side Block <> For Insulated Glazing E1-1286 For 1" Glazing E2-0105 2.500" x 2.313" x 0.050" EPDM with Pressure Sensitive Adhesive Effective Date: July 15, 2004 Page-4 YCW 750 OG Curtain Wall System ACCESSORIES YKK a~ #12 x 3/4" FHSMS l5J End Dam Plug E2-0505 ~ Type AB, Exposed Fasteners FC-1212 Use with E9-1223 & For Attachment of E9-1231 Horizontal to Shear Block #12 x 1-1/4" FHSMS Standard Joint Plug E2-0125 ~\\\\\\\\\\\\\\\ Type AB, Concealed Fasten. FC-1220 @J For 1/4" Glazing For Attachment of EPDM Sponge Horizontal to Shear Block #14 x 5/8" FHSMS ~ Standard Joint Plug E2-0102 ~ Type AB FC-1410 For 1" Glazing For Attachment of Mullion EPDM Sponge End Cap E1-1286 Joint Plug 1/4" - 20 x 5/8" HWHS G!r For slide in mullion E2-0129 ijIEa Type F HF-2510 at end bays, 1/4" glazing For Attachment of Use with E2-0123 Shear Block to Vertical Joint Plug 1/4" - 20 x 1" HWHS G:O For slide in mullion E2-0124 @ Type F, For Attachment of HF-2516 Shear Block to Vertical at end bays, 1" glazing with Steel Reinforcing Use with E2-0123 t 1/4" - 20 x 1" HWHMS E-Slot Plug E2-0123 ~ For Attachment of HM-2516 For slide in mullion Pressure Plate to Mullion at end bays & "J" Anchor at Jamb Isolator Tape ~.. 1/4"-20 x 3-1/2" HWHMS HM-2556 II 1/8" x 7/16" E2-0239 For Attachment of "J" Anchor Use with Perimeter at Intermediate Vertical Pressure Plate 0 1/4"-20 Nut HHMS Anchor Slip Pad E3-0103 ~ For Attachment of" J" Anchor HM-2500 For Dead Load at Intermediate Vertical & Wind Load Anchors & Jamb 1/4" Flat Washer ~ Interior/Exterior E2-0120 @ For Attachment of "J" Anchor WW-2500 Glazing Gasket at Intermediate Vertical & Jamb #8 x 3/8" PHSMS 1/4" Lock Washer (Q) For Attachment of" J" Anchor WS-2500 ~ For Attachment of PC-0806 at Intermediate Vertical Glazing Adaptors & Jamb #8 x 1/2" FHSMS ~ Type AB, Undercut FC-0808 For Attachment of Face Cover Splice Sleeve Effective Date: July 15, 2004 . Page-5 YKK aR YCW 750 OG Curtain Wall System FRAME FABRICATION FRAME TYPES I ANCHORING METHODS The following is a guideline for common types of frames. Refer to shop drawings for exact layout of frames. SINGLE SPAN MULTI-SPAN . . .'. .. :,':': i':-:,. ::. : Vertical End* Attachment Vertical End* Attachment .". ." .... Wind Load Anchor Vertical End* Attachment . '. ..., . ". ] [ 1 r 1 '" TWIN SPAN . :.. :.: : Vertical End* Attachment Vertical End* Attachment ':.::'''' :~.'.<:, -:~'" ~:;. Smaller units may be assembled on the ground and tipped in place. Larger units require being stick assembled in place. Note: If YKK does not prepare the shop drawings for the project, a qualified engineer must approve all anchors, their arrangement, and mullion selection. All anchors must be attached to structurally sound material that will accommodate the anchor reactions. * Vertical end attachment will be continuous perimeter anchor, "J" anchor, or mullion end anchor. Fabrication of yeW 750 OG varies depending on the type of vertical end attachment required for a given project: Perimeter Anchors are for low load anchoring conditions (maximum 5001b. end load reaction): E9-1248, E9-1223, & E9-1231 "J" Anchors are for medium to high load conditions: E1-3501, E1-3502, & E1-3505. Mullion End Anchors "F" & "T" are for high load conditions: E1-1207, E1-1208, E1-1209, E1-1231, E1-1232, E1-1233, E1-1238, & E1-1240 Page-6 Effective Date: July 15, 2004 YCW 750 OG Curtain Wall System YKK a~ FRAME FABRICATION FRAME TYPES I ANCHORING METHODS Using Perimeter Anchors: -Vertical mullions must be notched as shown in Detail 1 on Page-8. Using Mullion End Anchors: YCW 750 OG has three possible end anchoring conditions: "J", "T", and "F". -"J" anchors are used with jambs and intermediate verticals at the sill only. -'T' anchors are used with intermediate verticals at the head and sill. -"F" anchors are used with jamb mullions at the head and sill. -Anchor usage depends on end reaction, stress, and attachment. Mullions should be pre-assembled with shear blocks/clips, end anchors, and steel or aluminum reinforcing if necessary. Framing Members for Stick Build: -Head and sill members must be notched as shown Detail 9 on Page-14 to clear the mullion end anchors. -Closed horizontal members are used at all intermediate locations except at end bays. -Open back intermediate horizontals are used at end bays to clear the shear clips. Note: When using stick build construction, check overall frame width every fifth mullion as the wall is installed to prevent the buildup of cumulative tolerance errors. ~ . . . 4 . . 4 . 4 . . . . . 4 Head Receives Notch in Last Bay ~ . . ".. ... . ~ . . . STICK BUILD . . Sill Receives Notch in Last Bay . . : . Effective Date: July 15, 2004 Page-7 YKK a~ YCW 750 OG Curtain Wall System FRAME FABRICATION FABRICATE VERTICAL MULLIONS TOP END Notch Top and Bottom of Vertical & Jamb Mullions 7/S" Detai/1 7/8+== Step 1 -Cut all vertical and jamb mullions to dimensions as shown on shop drawings. Allow for 1/2" caulk joint around the frame & 1/2" joint at vertical splices. Step 2 -If you are using continuous perimeter anchors, E9-1223 or E9-1248, the top and bottom of vertical and jamb mullions must be notched as shown in Detail 1. Note: Do not notch verticals when using mullion end anchors: "J". liT". or "F". Effective Date: July 15, 2004 Page-8 YCW 750 OS Curtain Wall System YKK a~ FRAME FABRICATION STEP 3 FABRICATE VERTICAL MULLIONS -Mullion hole locations for shear blocks, shear clips, and "J" anchors are shown below. -Drill 0.213" dia. (#3 drill bit) holes for shear block/clip attachment at the locations indicated. Drill 0.281" dia. (#9/32 drill bit) holes for "J" anchor attachment at the sill. See Detail 2. Note: Hole locations for shear clips, E1-1213 & E1-1214, are not the same as for shear blocks and "J" anchors. "A" ~ Jamb II Dim "A" Dim"B" 6-3/4" 4-3/8" I ~ 5-1/4" 2-3/4" I I ...... Intermediate I 3-3/4" 1-1/2" ...... Vertical Head IlA" 0.213" Dia. Typical "B" (Shear Blocks) 1-1/8" : ~~ "B" N Ill'- ;=: U ~ 1-1/8" r r r L... ~=~=======--=== I I I I , I I I I 1=1=========r i I .---. : ~=~=========~==J I I I I I I I I I I 1=1=========1===: .---. : ~ : L... .J r L... 1: OJ "ij) :::c c g "S ::E Q; E III U: Top of Horizontal 0.213" Dia. (Shear Clips) Top of Horizontal ~ ...... I ...... (0 ...... M ...... I ...... 0.281" Dia. ("J" Anchors) r L... Sill Sill ~ L... ~ =3~ ...... III 0 U..., Shear Blocks ~ ...... I ...... Shear Clips I "J" Anchor , ::t ...... I ...... Detail 2 Effective Date: July 15, 2004 Page-9 YCW 750 OG Curtain Wall System YKK aR FRAME FABRICATION STEP 4 USING ALTERNATE REINFORCING If your engineering calculations require the vertical mullions to be reinforced with either steel or aluminum, secure the reinforcing to the vertical using the appropriate fasteners. -Start 3" from both ends of the mullion and install a fastener on both sides of the mullion tongue. -Stagger the fasteners on either side of the tongue going up the vertical. -Seal all screw heads with sealant. Top of Mullion Note: Exact size of reinforcing, size and location of fasteners to be determined by a qualified engineer. Optional reinforcing is also attached on the sides of the mullion with the attachment of shear blocks. -Drill 0.281" dia. (9/32 bit) clear holes in the mullion only. -Match drill 0.213 dia. (#3 bit) tap holes in the reinforcing only. -Attach the shear blocks with HF-2516 fasteners. See Detail 3. Steel Reinforcing Flat Head r Fastener HF-2516 Fasteners 0.281" Dia. (Through Mullion Only) 0.213" Dia. (Through Steel Only) ~ , i~~ , _l~~-"'''''''''''' Detail 3 , , ...) $ $ x '---' - I1l ::;E ~ - $ x I1l ::;E $ '----, - x ~ - I1l ::;E $ $ '" Co ..- Co ..- Co ..- '" Bottom of Mullion Page-10 Effective Date: July 15, 2004 YCW 750 OG Curtain Wall System YKK a~ FRAME FABRICATION STEP 5 ATTACH SHEAR BLOCKS/CLIPS FOR HORIZONTALS Shear blocks are used to attach one piece horizontal members to the jamb and vertical mullions: E 1-3503 for 3-3/4" back members. E 1-3504 for 5-1/4" back members. E1-3506 for 6-314" back members. Shear clips are used to attach two piece intermediate horizontal members to the jamb and vertical mullions: E1-1213 for 5-1/4" back members. E1-1214 for 3-3/4" back members. -Attach the shear blockslclips to jambs and verticals with two HF-2510 fasteners per block. See Detail 4. Note: See Step 4 on the previous page when using alternate reinforcing. Head Head E1-3504 Shear Block E 1-3504 Shear Block Inter. Horizontal Inter. ~ Horizontal ;.--- ~ HF-2510 E1-1213 Shear Clip -, HF-2510 Sill E1-3504 Shear Block Sill E 1-3504 Shear Block Detai/4 Effective Date: July 15, 2004 Page-11 YCW 750 OG Curtain Wall System YKK SF! FRAME FABRICATION STEP 6 ATTACH "J" ANCHORS In addition to anchoring the curtain wall frame to the structure, "J" anchors are used to attach sill members to jamb and vertical mullions: E1-3501 for 3-3/4" back members. E 1-3502 for 5-1/4" back members. E 1-3505 for 6-3/4" back members. Note: "J" anchors are used at the sill only. Attach "J" anchors at jambs: -Align the "J" anchor with the mullion and insert the HM-2516 bolts through the inside of the mullion and out the "J" anchor. -Install 1/4" flat and lock washers between the anchor and HM-2500 hex nuts. Attach "J" anchors at intermediate verticals: -Align the "J" anchors and insert the HM-2556 bolts through both anchors and the mullion. -Install 1/4" flat and lock washers between the anchor and HM-2500 hex nuts. See Detail 5. JAMB INTERMEDIATE VERTICAL , I HM-2516 ~ HM-2500 E1-3502 Detail 5 "J" Anchor HM-2500 E 1-3502 "J" Anchor Page-12 Effective Date: July 15, 2004 YCW 750 OS Curtain Wall System FRAME FABRICATION YKK a~ STEP 7 FABRICATE HORIZONTAL MEMBERS -Cut all horizontal members to the daylight opening as shown in shop drawings. -Horizontal members must be fabricated as shown below to attach to shear blocks or clips. Horizontals with Exposed Fasteners: -Layout hole locations on the top of the horizontal at both ends as shown below. -Drill 0.236" diameter (#B bit) holes and countersink for #12 flat head fasteners. See Detail 6. .. ~ ...... -- ~ Dim "A" Dim "8" 6-3/4" 4-3/8" 5-1/4" 2-3/4" 3-3/4" 1-1/2" -+- ~ I g. c} N "0 o 0 =' - ![ 0.236" Oia. C'Sink for #12 Flat Head -+- Detai/6 I. Daylight Opening (OLO.) .1 Horizontals with Concealed Fasteners: -Layout hole locations on the face of the horizontal at both ends as shown below. -Drill 0.236" diameter (#B bit) holes and countersink for #12 flat head fasteners. See Detail 7. 11/16" 0.236" Oia. C'Sink for #12 Flat Head Detail 7 II ->~~~~~- --- - ------- -- Co ~ -- ~ ~ I~ Daylight Opening (D.L.O.) ~I Effective Date: July 15, 2004 Page-13 YKK a~ YCW 750 OG Curtain Wall System FRAME FABRICATION STEP 7 (Continued) FABRICATE HORIZONTAL MEMBERS Two Piece Horizontals: -Layout hole locations on the bottom of the horizontal along the "V"-grooves at both ends. -Drill 0.213" diameter (#3 bit) holes at each location. Be careful not to penetrate the outer wall of the mullion. See Detail 8. Detail 8 0.213" Dia. Holes ~V-Groove,l+-- r--------~-+-- \4 Daylight Opening (D.L.O.) .[ If Mullion End Anchors Are Used Head and Sill Members Require Additional Fabrication: -Head and sill members must be notched out at each end to clear mullion end anchors and anchor bolts. -See Detail 9 below for notch dimensions. ~,u """""11 14 .1 "A" Dim "A" Dim"B" 6-3/4" 6-1/4" 5-1/4" 4-3/4" 3-3/4" 3-1/4" Detail 9 Notch Horizontal Ends to Clear End Anchors & Anchor Bolts Effective Date: July 15, 2004 Page-14 YCW 750 OG Curtain Wall System FRAME FABRICATION STEP 7 (Continued) FABRICATE HORIZONTAL MEMBERS One Piece Horizontals at End Bays (E-SLOT): When using one piece horizontals at end bays, horizontals must slide in from the interior. In order to clear the shear blocks on the verticals: -Notch the face and tongue of the horizontal at both ends as shown below. See Detail 10. 7/16" <<> .... in 27/32" E-SLOT 9/16" 27/32" 5132" . se 1-13/16" .... Detai/10 YKK a~ Effective Date: July 15, 2004 Page-15 YKK aR YCW 750 OG Curtain Wall System FRAME FABRICATION STEP 8 FABRICATE PRESSURE PLATES Horizontal Pressure Plates: -Cut horizontal pressure plates to the daylight opening between verticals minus(-) 1/8". -Pressure plate stock lengths have 0.281" dia. holes factory punched every 9". After cutting, drill additional holes if required to ensure that end holes are within 1-1/2" of each end. -Drill two 0.313" (5/16") diameter weep holes 3" from each end and one at the centerline of the pressure plate. See Detail 11. 0.313" Dia. Weep HOle',\ ~ Daylight Opening 3" & Pressure Plate 3" c I. wi I I- -I ~ g I eeL '3 CD ::2: a r r -----0 lii ~ 'f}-- '1 l J ~ u t 1 1/ T ;:l. ~ '\ o' - "- eL 0 A s:: Q) =- Cl 0.281" Dia.~ i "C o' W :::l Holes 1-1/2" g"O.C. g"O.C. 1-1/2" Max. Maximum Maximum Max. Pressure Plate Length = D.L.O. - 1/8" - I-- Daylight Opening (D.L.O.) "V" Grooves 1/16" 1/16" Detai/11 Vertical Pressure Plates: -Cut vertical and jamb pressure plates to the same length as the vertical mullions unless verticals are spliced. -If vertical mullions are spliced, cut pressure plates to accommodate for 1/2" expansion joint as shown in Step 10 on Pages 18 & 19. -Drill additional attachment holes if required to ensure that end holes are within 1-1/2" of each end. Effective Date: July 15, 2004 Page-16 YCW 750 OG Curtain Wall System YKK aR FRAME FABRICATION STEP 9 FABRICATE FACE COVERS Horizontal Face Covers: -Cut horizontal face covers to the daylight opening between verticals minus(-) 1/16". -Drill two 0.313" diameter weep holes at 1/3 points of cover as shown below. See Detail 12. 1/32" c c g g "5 "5 ~ ~ ro ro () () t t ~ ~ - ~ ~ - 0 0 Q) I I Q) Cl Cl "0 "0 W I I w 1/3 Points of I I 1/3 Points of Cover Length l Cover Length Cover Length = Daylight Opening (D.L.O.) - 1/16" Daylight Opening (OLD.) E9-1206 Face Cover 0.313" Dia. Weep Hole 1/32" Detai/12 Vertical Face Covers: -Cut vertical face covers to the same length as the vertical mullions unless the verticals are spliced. -If vertical mullions are spliced, cut vertical covers to accommodate for the 1/2" expansion joint as shown in Step 10 on Pages 18 & 19. Effective Date: July 15, 2004 Page-17 YKK aR YCW 750 OG Curtain 'Nail System STEP 10 TYPICAL VERTICAL SPLICE FRAME INSTAllATION Stagger Mullion, Pressure Plate, and Cover Splice Joints as Shown Below. Mullion Splice Sleeve E1-1201 (5-1/4") E1-1212 (3-3/4") E1-1299 (6-3/4") Detai/13 Cover Splice Sleeve E1-1202 Vertical Mullion Splice <t Pressure Plate Splice <t I I II I I I I I I II LJ ___________J..J rl-------------~ 11 II I, II II II II II II 11 II II II 11 'I II Cover Splice " " " " " " 'I II II ~L_____________~ E1-1202 Cover Splice ~~ ~ ! r n,___ n~-~I~i~~ ~p- ~:~ - n -- ~ II ~ II : : Sleeve :: I j II I I II I I II I I It I I II I I II I I II I I II I I II I I II I I II ~ C") I N N ~ C") I N (0 ~ ...... I II I II I II I II kit $i! I II I II I II I : 3/4" 3/4" :: I I II I I II I I II L~____~_______~________________u M ~ ...... I ...... <t ~ ...... Page-18 Effective Date: July 15,2004 YCW 750 OG Curtain Wall System YKK a~ FRAME INSTAllATION STEP 10 (Continued) TYPICAL VERTICAL SPLICE -Clean all surfaces as recommended by sealant manufacturer. -Apply bond breaker tape to the face of the splice sleeve at its midpoint (3" from top or bottom). -Lower the splice sleeve into top of lower mullion 2-3/4" and attach with two FC-1212 fasteners on both sides of the mullion. Screws should be installed 3/4" from the front and back of mullion and 1" down from the top. -When using 1" glazing mullions, stuff a small piece of backer rod 1/2" down the cavity behind mullion tongue and pump in sealant to fill the cavity. -Apply sealant to the face of splice sleeve on the upper half and carefully slide the upper mullion down onto the splice sleeve. Place a 1/2" temporary shim between the mullions to locate them. -Secure the upper mullion to the mid anchors and remove the temporary shims. -Apply and tool sealant to the face and sides of the splice sleeve to... create a water tight joint. -Leave a 1/2" expansion joint between vertical pressure plate splices and fill the joint with sealant. -Locate pressure plate fasteners 1-112" from each end of pressure plate splice as shown. Vertical Cover -Apply bond breaker tape to the face 24' Maximum of the cover splice sleeve and attach it to the lower face cover with a FC-0808 fastener on each side. -Prior to snapping on the upper portion of the face cover, apply sealant to the face of the splice. -Leave a 1/2" expansion joint between face cover splices. See Details 13 & 14. Note: Face covers, pressure plates, and mullions are staggered at splice locations. 1/2" ~ 1/2" Bond Breaker Tape Detai/14 Pressure Plate -u Splice Sleeve 6" Long g"o.c. Max. g" O.C. Max. 3/4" Vertical Mullion Effective Date: July 15, 2004 Page-19 YKK aR YCW 750 OG Curtain Wall System FRAME INSTALLATION STEP 11 INSTALL CONTINUOUS PERIMETER ANCHOR Seal Watertight with Sealant Perimeter Fasteners As Required By Calculations (Not By YKK) Continuous Perimeter Sealant Butt Perimeter Anchors Together Continuous Perimeter Anchor Detai/15 0.313" Dia. n n Weep Holes ~ 3" On Each Side of Vertical Centerline -Cut perimeter anchors to size: Head and sill anchors stop 1/8" short of the structure. Vertical jamb anchors butt in between head and sill anchors. -Prepare structure for anchor attachment. -Install perimeter anchors with appropriate perimeter fasteners. Refer to shop drawings or engineering calculations for type and spacing of fasteners. Shim as required to install anchors level. -When splicing head and sill pieces together, leave 3/8" joint for expansion and install end plug, E2-0505, that has been buttered with sealant on the front, back, and bottom at the joint. -Run continuous sealant along the perimeter between the anchors and the substrate. -Seal corners of butted perimeter anchors watertight with sealant. -Butter E2-0505 end plug with butyl on all sides that touch the anchors. Then push end plug into place and tool excess sealant that comes through the cracks. -Field drill 0.313" diameter weep holes in perimeter anchor (exterior face only) at sill 3" from center line of vertical on each side. See Detail 15. Effective Date: July 15, 2004 Page-20 YCW 750 OG Curtain Wall System YKK aR FRAME INSTAllATION STEP 12 JAMBNERTICAL INSTALLATION WITH PERIMETER ANCHORS -The notched ends of vertical mullions for 1" glazing leaves the interior of the mullion exposed and must be plugged prior to installation. -Install a small piece of backer rod into the notched out space directly behind the tongue at the top and bottom of the vertical mullions. -Push the backer rod into the opening at the face of the mullion. -Apply and tool sealant to seal off the opening made by the notch. -Install interior gasket, E2-0100, to jamb mullion Uamb side only) the full length of the mullion. -Position jamb into opening as shown in Detail 16. -Seal the gap between the perimeter anchor and vertical glazing pocket(s) with sealant (one side for jambs - both sides for intermediate verticals). -Install temporary retainer clip, E1-1294, at the top and bottom of the mullion. -Repeat this step for all jamb and vertical mullions. See Detail 16. It-- Spacing Per , I I Shop D<awlng' <J ... ... <J E1-1294 I I i _ -V Backer Rod I I I I I I I \~ ~ 1/2" Nom. <J "J ... Sealant E9-1223 Perimeter Anchor "J <J <J <;J " ~ Jamb <l Apply & Tool Sealant Between Perimeter Anchor & Mullion ~ " E9-1223 Perimeter Anchor Shims As Required Sill Detai/16 Effective Date: July 15, 2004 Page-21 YKK SF! YCW 750 OG Curtain Wall System FRAME INSTAllATION STEP 13 JAMBNERTICAL INSTALLATION WITH MULLION END ANCHORS -Clean all contact surfaces as recommended by sealant manufacturer. -Apply sealant into the screw raceway and along the front edge of the mullion at each end. -Prior to erecting verticals, install mullion end caps, E1-1286, at the top and bottom of the mullions with FC-1410 fasteners. -Seal all screw heads with sealant. See Detail 17. FC-1410 Seal All Screw Heads Apply & Tool Sealant E1-1286 Detai/17 -Insert mullion "T" and "F" anchors into the top and bottom of the mullions before erecting them into the opening. -Erect and locate the jamb and vertical mullions and temporarily attach them to the structure. All mullions must be installed plumb and true. -Field drill holes in "T", "F", and "J" anchors for the appropriate anchor fasteners according to shop drawings or engineering calculations. Consult YKK if load requirements are in question. See Detail 18. Field Drill Typical 'T Anchor "J" Anchor Detai/18 "T" Anchor Shim As Required Field Drill Typical Field Drill Typical Effective Date: July 15, 2004 page-22 YCW 750 OS Curtain Wall System YKK af:.! FRAME INSTAllATION STEP 14 INSTALL WIND LOAD I DEAD LOAD ANCHORS -Install steel wind load and dead load anchor clips. Anchor clips are normally template or line set before mullions are hung. Outstanding leg of clip must be set at 900 to offset line. The back of the vertical mullion should set 1" from the anchoring substrate. See Detail 19. @ <I ~ 0) <I ~ <I .~ ~ c::=J @ <I 0) <I <I ... ... <l <l Wind Load ~ Dead Load ~ Anchor Detail 19 Anchor -Install, plumb, and align vertical mullions. Drill and install appropriate diameter anchor bolts. If shop drawings are not prepared by YKK AP, all anchors and bolts must be checked by a qualified engineer. -Nylon slip pads, E3-0103, must be installed between mullion and anchor. See Detail 20. E L E 0 0 Z Jtl ~ . Z <I . ~ . ..- '" E1-1204 WIL E1-1205 OIL Detail 20 E3-0103 Nylon Slip Pad Anchor Bolts See Shop Drawings Not By YKK For Weld Type & Sizes Effective Date: July 15, 2004 Page-23 YKK aR YCW 750 OG Curtain Wall System FRAME INSTAllATION TYPICAL WIND LOAD ANCHOR Vertical Mullion E3-0 1 03 Nylon Slip Pad Note: Drill holes in mullion centered along the slots to permit the frame to contract and expand. ~ Flat Washer See Shop Drawings or Engineering Calculations For Correct Bolt Size (Not By YKK) ~ ~ Lock Washer Detail 21 TYPICAL DEAD LOAD ANCHOR See Shop Drawings or Engineering Calculations For Correct Bolt Size (Not By YKK) Vertical Mullion E3-0103 Nylon Slip Pad E1-1205 Dead Load Anchor ~ Note: Fasteners are shown for reference only; horizontals are typically attached before anchor fasteners are installed. Effective Date: July 15, 2004 Page-24 "If YCW 750 OG Curtain Wall System YKK a~ FRAME INSTALLATION STEP 15 ATTACH HORIZONTAL MEMBERS -Just prior to attaching the horizontal members to the vertical, apply sealant to the front of the shear block as shown below. Note: Before applying any sealant, clean aluminum surfaces using cleaner and method approved by sealant manufacturer. For Concealed Fasteners: -Slide the horizontal members towards the vertical and attach them to the shear blocks at each end with two FC-1220 fasteners. - Tool and wipe away any excess sealant at the vertical to horizontal joints. See Detail 22. For Exposed Fasteners: -Slide the horizontal members towards the vertical and transfer the hole locations on top of the horizontal to the shear block. -Remove the horizontal and drill a 0.189" dia. (#12 bit) hole at each hole location. -Slide the horizontal back against the vertical and attach it to the shear block with two FC-1212 fasteners at each end. -Tool and wipe away any excess sealant at the vertical to horizontal joints. See Detail 23. CONCEALED FASTENERS Detail 22 EXPOSED FASTENERS Detail 23 Effective Date: July 15, 2004 Page-25 YKK a~ YCW 750 OG Curtain Wall System FRAME INSTALLATION STEP 15 (Continued) ATTACH HORIZONTAL MEMBERS For Two Piece Horizontals: -Lower the horizontal down onto the shear clip. Make sure the horizontal and vertical glazing pockets are flush. -Attach the horizontal to the shear clip from the underside of the horizontal using two HF-2510 fasteners at each end. -Snap on the horizontal cover. See Detail 24. Detail 24 At Head and Sills: TWO PIECE HORIZONTAL Horizontal Cover -Mullion end anchors must be installed before head and sill members are attached. -Provide anchor fasteners as per job requirements. See approved shop drawings or engineering calculations for appropriate anchor fasteners. -Install the anchor fasteners as recommended by fastener manufacturer. -Attach head and sill members according to the procedures previously outlined with the notched out portion facing the anchors. See Detail 25. Caution: There must always be a shim under the mullion to transfer glazing dead loads to the foundation. Detail 25 Anchor Fasteners Not By YKK Page-26 Effective Date: July 15, 2004 YCW 750 OG Curtain Wall System YKK a~ FRAME INSTALLATION STEP 15 (Continued) ATTACH HORIZONTAL MEMBERS For One Piece Horizontals at End Bays: -Slide the horizontal into place from the interior; the shear blocks should easily pass through the E-Slots at the ends of the horizontal. Make sure that the glazing pockets are flush. -Attach the horizontal to the shear block at each end with FC-1212 fasteners as previously instructed for exposed fastener attachment. See Detail 26. Apply Sealant To All Contact Sides of Plug -Apply sealant to all contact sides of the E-Slot plug, E2-0123. -Insert the E-Slot plugs into place and press them firmly against the shear blocks. -Cover the entire slot with sealant and tool the sealant to ensure a watertight seal. See Detail 27. Detail 26 Apply & Tool Sealant Horizontal Detail 27 Effective Date: July 15, 2004 Page-27 YKK a~ YCW 750 OG Curtain Wall System FRAME INSTALLATION STEP 16 APPLY PERIMETER SEALANT -Clean the area around the perimeter of the frame with cleaner and method approved by sealant manufacturer. -Push in backer rod between the perimeter of the frame and the substrate about 1/4". -Apply a quality sealant to the perimeter of the frame. -Tool the sealant making sure that sealant does not get into the gasket reg lets. See Detail 28. c - '0 0.1-' --~ ...... - ::l ('tl U Ol C 'c a> 0- o ~ c o III ('tl ~ - c '0 . -, ~~ ...... - ::l ('tl U :E Ol 'CD I a> E ('tl .... u.. c ('tl (ij a> U) cl:S "C o c:x:: .... a> ~ u ('tl co 1/2" Caulk Joint Frame Width Masonry Opening Detail 28 Page-28 Effective Date: July 15, 2004 YCW 750 OS Curtain Wall System YKK a~ FRAME INSTALLATION STEP 17 INSTALL JOINT PLUGS Long Leg Against the Vertical Tongue Detail 29 The tongue of each horizontal must be sealed to the tongue of the vertical mullions. The space between the two tongues is closed by using joint plugs, E2-0102 for 1" glazing or E2-0125 for 1/4" glazing. -Clean the area around the tongue intersection with an approved cleaner. -Apply and tool sealant to the intersection of the horizontal and vertical. -Apply sealant to the three contact sides of the joint plug and at the intersection of the vertical and horizontal glazing pocket. -Install joint plug as shown with the long leg of plug against the vertical tongue. -Press joint plugs firmly against face of mullion. -Tool the sealant to ensure a watertight seal. -Seal all exposed screw heads on the face of the mullion. See Detail 29. Effective Date: July 15, 2004 Page-29 YKK a~ YCW 750 OG Curtain Wall System GLAZING STEP 18 INSTALL GLAZING ADAPTORS (When Required) I'" Daylight Opening .1 Jamb Mullion Interm. Vertical Apply sealant into reglet before installing adaptors ) IA. .1 1 Horizontal Adaptor Cut Length PC-0806 Daylight Opening - 1/32" Note: 1/4" glazing adaptor, E9-1220 shown 1/2" glazing adaptor, E9-1232 similar. .r:. - . OlCO m r::: - + "5 Ol U c (; 'c - Q) 0. 0. {g 0 <( :E (ij .2> u >- t ('tl ~ 0 i PC-0806 Detail 30 (J- -Cut glazing adaptors to size: Vertical Cut Length = Daylight Opening plus(+) 7/8". Horizontal Cut Length = Daylight Opening minus(-) 1/32". HORIZONTAL Seal intersection of adaptors Ol C 'c Q) 0. o Apply sealant into reglet before installing adaptors - .r:. .2> >- ('tl o HORIZONTAL -Predrill each adaptor with 0.189" dia. (#12) holes 2" from each end. -Dry fit adaptors and match drill 0.141" diameter (#28) holes on mullion to receive PC-0806 screws. -Clean the area around the mullion glazing reg let and the glazing adaptor with a cleaner approved by the sealant manufacturer. -Apply sealant into the glazing reg let of the mullion and the ends of the horizontal adaptors. -Install the adaptors with PC-0806 screws 2" from each end and at the center of the adaptor. Install the vertical adaptors first and make sure they are centered along the day light opening. -Tool sealant at all adaptor intersections and seal all screw heads. See Detail 30. E9-1220 Glazing Adaptor Page-30 Effective Date: July 15, 2004 YCW 750 OG Curtain Wall System YKK a~ GLAZING STEP 19 INSTALL INTERIOR GLAZING GASKETS -Cut interior glazing gaskets to size: Vertical Gasket = Daylight Opening + 1-1/4". Horizontal Gasket = Daylight Opening + 1/8" per each foot of opening width. -Install vertical gaskets first, centered along the daylight opening. -Install horizontal glazing spacers next. -Insert the glazing spacer into the reglet at each end first. -Snap the rest of the glazing spacer into the reg let starting at the center and work towards each end. Apply Sealant Along Reglet & End of Gasket Detail 31 Apply and Tool Sealant at Gasket Intersection -Pull the last 3" of each gasket away from the reg let. -With gasket end held out of the way, run a 2-3" bead of sealant into the reglet at the ends. -Apply sealant at the ends of the horizontal gaskets. -Reinsert the ends of the gaskets pressing them firmly against the face of the mullions. -Apply and tool sealant at the intersection of the vertical and horizontal gaskets. See Detail 31. Effective Date: July 15, 2004 Page-31 YKK a~ YCW 750 OG Curtain Wall System GLAZING STEP 20 INSTALL SETTING & SIDE BLOCKS (.0) ( IT (0\ i------------~--~------ --------------- Glazing v"- Vertical Honzontal : Side / IY Block I I I " - f- ~ Daylight Opening / I I I I I I I I I I 1/2" 6" Minimum 4" Setting . I Setting r _~r~~ _E~=~ ~f_~~S~ _ ~r _ ~~~~ ~~~h_ _\_~ ~~o~~ _ _ _ _ _ __ II (0) ( @ Detail 32 1/2" ~ -Install setting blocks, E2-0104 for 1" glazing or E2-0112 for 1/4" glazing, at 1/4 points of D.L.O. or minimum of 6" from edge of glass, whichever is greater. Consult YKK AP for setting block requirements on units that exceed 60" x 90" or 40 sq. ft. -Install side blocks, E2-0105 for 1" glazing or E2-0113 for 1/4" glazing, centered along the daylight opening on both sides of glazing material. See Detail 32. Effective Date: July 15, 2004 Page-32 YCW 750 OG Curtain Wall System YKK a~ GLAZING STEP 21 INSTALL EXTERIOR GLAZING GASKETS -Cut exterior vertical glazing gaskets to the same length as the vertical pressure plates. -Cut exterior horizontal glazing gaskets to daylight opening plus 1/8" per foot of opening width. -Install vertical glazing gaskets onto the vertical pressure plates. -Install horizontal gaskets by pushing each end into the reglet of the pressure plate. Next press center of gasket into reg let; then push gasket into reg let working from center towards the ends. Caution: Do not stretch the gaskets. Daylight Opening ,- -, ~ ~ Cl r::: ';:: Q) c- O :E .!2l >- co Cl ~ + Cl r::: ';:: Q) c- O :E .!2l >- co Cl I. .1 Daylight Opening + 1" STEP 22 INSTALL GLASS Detail 33 -As each lite is installed, attach a temporary retaining clip, E1-1294, in the middle of each horizontal and 4" from glass edge at each end using HM-2516 fasteners. -Reuse the temporary retaining clips. -Apply sealant to the face of the joint plugs just prior to installing vertical pressure plates. Do not allow sealant to skim over prior to installing pressure plates. Note: Sealant must form a complete seal between the exterior gasket, pressure plate, thermal isolator, and the joint plug. See Detail 33. Apply Sealant To Face of Joint Plug E1-1294 Temporary Retainer Clip Glass and Spandrel Size = Daylight Opening + 1" horizontally and vertically. Effective Date: July 15, 2004 Page-33 YKK a~ YCW 750 OG Curtain Wall System GLAZING STEP 23 PRESSURE PLATE LAYOUT AND ASSEMBLY r E2-0239 ~ *Pressure plate layout shown for 1" glazing, 1/4" glazing similar but use perimeter pressure plate, AS-3572. ~ AS-3569* AS-1216 liY Jamb liY Vem~1 Weep Hole ~ Daylight Opening Intermediate ! Horizontal I 3" 3" e x ('tl ~ U o en + ~ AS-1216 1-1/2" 9" O.C. Max. 9" O.C. Max. Max. x ~ Daylight Opening ('tl ~ I ~ 3" Sill , 0 I en + ~x 1/16" .....ro ~~ 1-112" 9" O.C. Max. 9" O.C. Max. Max. 1-1/2" Max. en iJ 1/16" AS-3569* 1-1/2" Max. Detail 34 -Pressure plate stock lengths are factory punched with 0.281" diameter holes at 9" o.c. maximum. After cutting, additional holes may be required to have bolts within 1-1/2" of each end. -Install isolator tape, E2-0239, onto the back leg of the perimeter pressure plates. -Install vertical pressure plates using HM-2516 bolts. Initially torque bolts to 30 inch pounds with a speed wrench or torque limiting screw gun. Work from the bottom up. -Center and install horizontal pressure plates in opening, leaving a 1/16" gap at the ends. -Starting at the center of each pressure plate, tighten each retainer bolt to 50 inch pounds. -Apply and tool sealant to completely seal gaps at the pressure plate ends. -Torque all vertical pressure plate bolts to 50 inch pounds. See Detail 34. Note: Pressure plate AS-1216 must be used instead of AS-3569 on the perimeter when using perimeter anchors. Mullion end cap, E1-1286, must be installed when using mullion end anchors: "F", "T", or "J". Effective Date: July 15, 2004 Page-34 YCW 750 OG Curtain Wall System YKK a~ GLAZING STEP 24 INSTALL EXTERIOR FACE COVERS -Snap on exterior covers using a mallet and a clean scrap piece of lumber. Start at one end and work block and mallet down the vertical and across the horizontal. See Detail 35. / Detail 35 e e Effective Date: July 15, 2004 Page-35 _<>AlE. BUILDING CODE COMPLlANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Carlisle SynTec, Inc. 1285 Ritner Highway Carlisle, PA 17013 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami-Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AlU). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (~ Miami Dade County) and/or the AIU (in areas other than Miami Dade County) reserve the right to, have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may iinmediately revoke, modify, .or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. I This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIYfION: Carlisle Single Ply EPDM Roof Systems over Steel Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and sh~ll be available for inspection at the job site at the request of the Building Official. j This NOA renews hnd revises NOA 04-0322.04 and consists of pages 1 through 15. The ,ubOOtted d7entation was reviewed eJ:- 0k 9 NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 1 of 15 ROOFING SYSTEM ApPROVAL Category: Sub-Category: Material: Deck Type: Maximum Design Pressure Fire Classification: Roofing Single Ply EPDM Steel -90 psf See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY ApPLICANT: TABLE 1 Product Name Sure-Seal EPDM Sure-Seal FR EPDM Sure Seal FR-Plus EPDM Sure-Seal Reinforced EPDM Sure-Seal Sure-Tough Sure-Seal Reinforced FR EPDM Sure-Seal Fleece BACK Sure Seal Fleece BACK AFX Sure Seal Fleece BACK AFX-Plus Sure-White EPDM Sure-White Fleece BACK EPDM RUSS CCW 702 Primer CCW 702L T Primer CCW 714 Primer CCW 725 Vapor Barrier FAST 100 Adhesive FAST I OO-L V Adhesive FAST 100-P Adhesive FAST 102 Adhesive OlyBond 500 BA Sure-White Lap Sealant Sure-Seal Lap Sealant Sure-White Splicing Cement Sure Seal EP-95 Splicing Cement SecurTape 8 Test Dimensions Specifications Product Description various ASTM D 4637 Non-reinforced EPDM membrane. various ASTM D 4637 Non-reinforced, fire retardant EPDM membrane. vanous ASTM D 4637 Reinforced EPDM membrane. various ASTM D 4637 Reinforced, fire retardant EPDM membrane. vanous ASTM D 4637 EPDM membrane with fleece backing. . vanous ASTM D 4637 Non-reinforced white on black EPDM membrane. . Various ASTM D4637 Non-reinforced white on black fleece backed EPDM membrane. various ASTM D 4637 Reinforced securement strip. vanous T AS 11 0 Solvent-Based Primer vanous T AS 110 Low-Temperature Solvent- Based Primer vanous TASllO Water-Based Primer vanous T AS 11 0 Vapor Barrier vanous T AS 11 0 Spray Polyurethane Adhesive TAS 110 Lap Sealant for Sure- White/Sure-Seal membranes. Splicing Adhesive for EPDM membranes. Tape Adhesive for EPDM membranes. TAS 110 T AS 110 NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 2 of 15 Product Name Sure-Seal 90-8-30A Bonding Adhesive Sure-Seal B-500 Bonding Adhesive Sure-Seal Metal Fastening Bars, ST Fastening Bars Aqua Base 120 Bonding Adhesive Cold Applied Adhesive ApPROVED INSULATIONS: Product Name ACFoam Composite ACFoam II, m Dimensions Test Specifications T AS 11 0 TAS 110 1" wide T AS 114 T AS 11 0 T AS llO TABLE 2 Product Description Isocyanurate Insulation with perlite facer Isocyanurate Insulation Polyisocyanurate lIP, lIP-N, HP-H, Polyisocyanurate roof insulation. lIP-W Sure-Seal lIP Recovery Board EPStFiberboard EPS Insulation Hytherm, Hytherm AP Styrofoam ISO 95+ GL, 95+ GW Dens Deck, Dens Deck Prime Sturdi-Top High Density Woad Fiberboard Perlite Insulation Board Type X Gypsum, Gypsum EPS or XPS Insulation Ultra/M - II H-Shield ENRGY 2, ENERGY 3, PSI-25 Foamular, Thermapink, Durapink ~ U High Density Wood Fiberboard. High Density Wood Fiberboard bonded to EPS. Expanded Polystyrene. Isocyanurate Insulation Extruded Polystyrene. Polyisocyanurate foam insulation Silicon treated gypsum Wood fiber insulation board. High Density Wood Fiber insulation board. Perlite Insulation Gypsum Wallboard Expanded or Extruded Polystyrene. Isocyanurate Insulation Isocyanurate Insulation Isocyanurate Insulation Extruded Polystyrene. Product Description Solvent-based bonding adhesive. Water-based bonding adhesive. Metal bars used for membrane securment. Water-based Bonding adhesive. Asphalt-modified polyether adhesive. Manufacturer (With Current NOA) Atlas Roofing Corp. Atlas Roofing Corp. Carlisle SynTec, Inc. Carlisle SynTec, Inc. Carlisle SynTec, Inc. Carlisle SynTec, Inc. Dow Chemical Dow Chemical Firestone G-P Products G-P Products Generic Generic Generic Generic Homasote Co. Homasote Co. Johns Manville Owens Corning NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 3 of 15 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Owens Coming Pactiv Strata guard Green Guard Gypsum Wallboard Extruded Polystyrene insulation Multi-Max, FA Polyisoeyanurate foam insulation Rmax, Inc. Fiber Base Asphalt coated wood fiber insulation Temple Inland Forest Products Corp. Wood Fiber Industries Structodeck High Density Wood Fiber insulation board. APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Sure-Seal lIP, lIP-X, Insulation and membrane Various Carlisle SynTee, Inc. lIP-Xtra, Sure-Tite fastener Fasteners 2. Sure-Seal Seam Metal plates used for 2" dia Carlisle SynTec, Inc. Fastening Plates membrane securement. 3. Sure-Seal Polymer Plastic plates used for 2" dia Carlisle SynTee, Inc. Seam Plates membrane securement. 4. Sure-Seal Insulation Plates used for insulation various Carlisle SynTec, Inc. Plates, Sure-FAST, securement. ASAP 5. Dekfast Fasteners # 12, Insulation and membrane Various SFS Intee, Inc. #14,#15 fastener 6. Dekfast Hex Plate Insulation and membrane Various SFS Intee, Inc. fastener 7. #12 & #14 Roofgrip Insulation and membrane Various lTW Buildex fastener 8. Metal Plate Gal valume AZ50 stress plate 3" square ITW Buildex 9. Plastic Plate Polyethylene stress plate 3.2" round ITW Buildex 10. Olympic Fasteners #12, Insulation and membrane Various Olympic Mfg. Group #14 fastener 11. Olympic Stainless Stainless steel insulation and Various Olympic Mfg. Group Fasteners #12, #14 membrane fastener 12. Olympic Standard Galvalume AZ55 stress plate 3" round Olympic Mfg. Group 13. Olympic Plastic, ASAP Plastic plates for fasteners. 3" round Olympic Mfg. Group 8 NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 4 of 15 ApPROVED FASTENERS: Fastener Product Number Name 14. Rawl Fasteners #12, #14 15. Rawl Insulation Plate 16. Insul-Fixx Fastener 17. Isofast Fasteners 18. Insul-Fixx S 19. Insul-Fixx P 20. Isofast Plate 21. Tru-Fast Fasteners 22. Tru-Fast Ultra Stainless Fasteners 23. Tru-Fast MP-3 24. Tru-Fast Plastic Plate EVIDENCE SUBMITTEn: Test Aeency Architectural Testing Inc. Factory Mutual Research Corp. 9 TABLE 3 Product Manufacturer Description Dimensions (With Current NOA) Fastener for steel and wood Various Powers Fasteners Inc. decks Galvalume AZ55 stress plate 3" round Powers Fasteners Inc. Fastener for steel and wood Various SFS Intec, Inc. decks Fastener for steel and wood Various SFS Intec, Inc. decks Galvalume AZ55 stress plate 3" round SFS Intec, Inc. Polyethylene stress plate 3" round SFS Intec, Inc. Square or oblong Galvalume SFS Intec, Inc. steel plates for use with Isofast fasteners Insulation and membrane Various The Tru-Fast Corp. fastener Stainless steel insulation and Various The Tru-Fast Corp. membrane fastener Galvalume AZ50 steel plate 3.23" round The Tru-Fast Corp. Polyethylene stress plate 3" round The Tru-Fast Corp. Test Identifier ATI-17601-02 ATI-18535 01-37183.02 J.I.1B7A5.AM 1998 Approval Guide Building Materials J.I. 2Z3A9.AM J.I.4B2Al.AM J.I.3B8Q4.AM J.I. OB4A7.AM J.I. 2B2Al.AM J.I. 2Z2A8.AM J.1. 3B5Al.AM J.I. 4D9A6.AM 1.1. 2D6A6.AM Letter Description Wind Uplift Classification Wind Uplift Classification UL 580 Date 07/30/96 10/14/96 06/29/00 Wind Uplift and Fire Classification Wind Uplift and Fire Classifications Wind Uplift and Fire Classification Wind Uplift Classification Wind Uplift Classification Wind Uplift Classification Wind Uplift Classification Seam Test Wind Uplift and Fire Classification Approval Report 08/03/98 Wind Uplift Classification 10/07/98 Wind Uplift Classification 09/15/98 NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 5 of 15 02/23/98 01/01/98 07/30/97 06/11/97 06/04/97 OS/29/97 OS/29/97 05/16/97 04/28/97 Test A2ency Test Identifier Description Date Factory Mutual Research Corp. 3003326 Class 4470 04/12/99 3000348 Class 4470 04/19/99 3012458 Class 4470 02/23/02 3020353 Class 4470 03/25/04 3009502 Class 4470 12/21/00 3024994 Class 4450 02/28/06 3013584 Class 4470 06/27/03 3019897 Class 4470 10/07/05 3022187 Class 4470 09/15/05 3022181 Class 4470 09/01/05 3014692 Class 4470 08/05/03 Underwriters Laboratories, Inc. 96NK21757 Fire Classification 09/06/96 96NKI0924 Fire Classification 10/31/96 96NK2887I Fire Classification 11/06/96 96NK33323 Fire Classification 10/24/97 1998 Roofmg R8103 Fire Classification 01/01/98 Materials & Systems Directory Letter Fire Classification 08/06/98 Letter Fire Classification 09/09/98 02NK46936 UL 790 12/15/03 ~ U NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 6 of 15 ApPROVED ASSEMBLIES Membrane Type: Single Ply, Thermoset, EPDM, Reinforced, Nonreinforced, Fleece Backed Deck Type 21: Steel, Insulated Deck Description: 18-22 ga. steel System Type A: All layers of insulation adhered to deck, membrane fully adhered. All General and System Limitations apply. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe Extruded or Expanded Polystyrene, Energy-Lok, ACFoam-II, ACFoam-III, Multi-Max FA, lIytherm AP, H-Shield, Ultra/M-n Iso/glas, ENRGY-2, ENRGY-3, PSI-25, AC Foam II, Polyisocyanurate HP, HP-W, UP-H, HP-N, ISO 95+GL, HF, Rhotlex GL, HF Minimum 1" thick N/A ACFoam Composite, Rhotlex Composite, Fesco Foam Minimum 1.5" thick Dens Deck, Dens Deck Prime Strataguard Minimum W' thick I N/A N/A N/A N/A N/A Structodeck, Fiber Base. High Density Fiberboard, Perlite, HP Recovery Board, Wood Fiber Minimum Yz" thick N/ A N/ A Note: All insulation shall be fully adhered to the deck with FAST Adhesive at a rate of 1 gal./sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Vapor Retarder: None. Barrier: Membrane: Surfacing: Maximum Design Pressure: 8 None. Sure-Seal or Sure-White FleeceBACK 100 or liS mil membrane fully adhered to the insulation using FAST 100 Adhesive applied to the substrate at a rate of I galllOOfF or Aqua Base 120 Bonding Adhesive applied to the substrate at a rate of 1 gal/l20 m. Or Sure-Seal or Sure-White 45 to 90 mil membrane fully adhered to the insulation using 90-8-30A applied to the substrate at a rate of 1 ga1l60 ft.2, or B-500 applied to the substrate at 1 gal./sq. Or i Sure-Seal FleeceBACK AFX or AFX Plus membrane adhered to the I insulation in a full tnopping of approved asphalt applied within the EVT range and at a rate pf20-25lbs.lsq or Cold Applied Adhesive applied to the substrate at a rate of 1 gal/67 fF. (Optional) A two-part surfacing consisting ofEM-8 Hypalon applied at the rate of 1 gal.l150 ft2 and silica sand applied into the wet coating at a rate of35 Ibs.lsq. or two coats of Sure-Seal Acrylic Coating at a rate 1.5 gal/sq. per coat. -90 psf. (See General Limitation #9) NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 7 of 15 Membrane Type: Single Ply, Thermoset, EPDM, Reinforced, Nonreinforced, Fleece Backed Deck Type 21: Steel, Insulated Deck Description: 18-22 ga. steel System Type C(1): All layers of insulation simultaneously attached; membrane fully adhered. All General and System Limitations apply. Insulation Layer Insnlation Fasteners (Table 3) ACFoam-II, H-Shield, ENRGY-3, PSI-25, Polyisocyanurate HP, HP-W, BP-H, BP-N, Minimum 2" thick 1 Fastener Density/ft2 1:1.6 ft2 Note: All layers of insulation shall be simultaneously fastened. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Vapor Retarder: None. Barrier: None. Membrane: Sure-Seal or Sure-White FleeceBACK 100 or 115 mil membrane fully adhered to the insulation using FAST 100 Adhesive applied to the substrate at a rate of I galllOOfF. Or Sure-Seal or Sure-White 45 to 90 mil membrane fully adhered to the insulation using 90-8-30A applied to the substrate at a rate of I gall60 ft.2, or B-500 applied to the substrate at 1 gaL/sq. (Optional) A two-part surfacing consisting ofEM-8 Hypalon applied at the rate of 1 gal.l150 fP and silica sand applied into the wet coating at a rate of35 lbs.lsq. or two coats of Sure-Seal Acrylic Coating at a rate 1.5 gal/sq. per coat. Surfacing: Maximum Design Pressure: -75 psf. (See General Limitation #9) ~ U NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 8 of 15 Membrane Type: Single Ply, Thermoset, EPDM, Reinforced, Nonreinforced, Fleece Backed Deck Type 21: Steel, Insulated Deck Description: 18-22 ga. steel System Type C(2): All layers of insulation simultaneously attached; membrane fully adhered. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 One of the following covered with the boards listed in Top Layer or Base or Top Layer. Extruded or Expanded Polystyrene Minimum I" thick N/A N/A Perlite Minimum W' thick N/A N/A Note: All layers shall be simultaneously fastened; see top or base layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Single and multiple layers of insulation can be adhered with OlyBond 500 BA or FAST Adhesive at minimum rate 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base or Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Multi-Max FA, Hythenn AP, UltraIM-1I Iso/glas Minimum 1.2" thick 1,5,7, 10, 11, 14, 16,21 or 22 1:2 ftl ENRGY-2, ENRGY-3, PSI-25, AC Foam II, AC Foam m, H-Shield, Polyisocyanurate HP" HP-H HP-N,HP-W Minimum 1.5" thick Minimum 2" thick 1,10,11,14 or 17 1,7,10,11,14,16,21 or 22 1:2 ftl 1:4 ftl ACFoam Composite, Rhoflex Composite, Fesco Foam Minimum 1.5" thick 1,5, 7, 16, 10, 11,14,21 or 22 1:3 ftl High Density Fiberboard Minimum %" thick 1,5,7,10,11,14,21 or 22 1 :2.67 ftl ISO 95+GL, HF, Rhoflex GL, HF Minimum 1.2" thick Minimum 1.4" thick 5,7 or 16 7,10,11,14,16,21 or 22 1:2 ftl 1:3 ftl Structodeck, Fiber Base, HP Recovery, Wood Fiber Minimum W' thick Dens Deck, Dens Deck Prime, Strata guard Minimum ~"tbick 5,10,11 or 14 1:2 ftl 1,5,7,10,11,14,21 or 22 1:2 ftl Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fr Required over tbe insulations listed in Base Layer or optional over any of the insulations listed as Base or Top Layer: L\ U NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 9 of 15 HP Recovery (for use over all insulation. types) Fiber Base (for use over polyisocyanurate, gypsum or perlite) Minimum W' thick 1 1:2 ftz Vapor Retarder: Barrier: Membrane #1: Membrane #2: Membrane #3 Surfacing: Maximum Design Pressure: 8 (Optional) Any UL or FM approved vapor retarder applied to the roof deck or over a base layer of insulation. None. Sure-Seal or Sure-White 45 to 90 mil membrane fully adhered to the insulation using 90-8-30A applied to the substrate at a rate of 1 gal/60 ft.2, or B-500 applied to the substrate at 1 gal.lsq. Maximum Design Pressure -45 psi (See General Limitation #9) Sure-Seal or Sure-White FleeceBACK 100 or 115 mil membrane fully adhered to the insulation using FAST Adhesive applied to the substrate at a rate of 1 gal/sq or Aqua Base 120 Bonding Adhesive applied to the substrate at a rate of 1 gal/120 ft2. Maximum Design Pressure -60 psf. (See General Limitation #7) Sure-Seal FleeceBack AFX or AFX Plus membrane adhered to the insulation in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 25 lbs./sq or Cold Applied Adhesive applied to the substrate at a rate of 1 ga1l67 ft2. Maximum Design Pressure - 60 psf. (See General Limitation #7). (Optional) A two-part surfacing consisting ofEM-8 Hypalon applied at the rate of I gaL/I 50 fF and silica sand applied into the wet coating at a rate of35 lbs./sq. or two coats of Sure-Seal Acrylic Coating at a rate 1.5 gal/sq. per coat. See Membrane Options Above NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29106 Page 10 of 15 Membrane Type: Single Ply, Thermoset, EPDM, Reinforced Deck Type 21: Steel, Insulated Deck Description: 18-22 ga. Steel. (See Deck Types noted below) System Type D(I): Membrane mechanically attached over preliminarily fastened insulation. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe One of the following covered with the boards listed in Top Layer or Base or Top Layer. Extruded or Expanded Polystyrene Minimum 1" thick N/A N/A Perlite Minimum W' thick N/A N/A Base or Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ENRGY-2, ENRGY-3, PSI-25, H-Shield, AC Foam II, AC Foam Ill, Polyisocyanurate HP, HP-W, HP-H, Polyisocyanurate HP-N, Multi-Max FA, Hytherm AP, Ultra/M-ll Iso/glas, ISO 95+ HF, Rhoflex UF, ISO 95+GL, GW, Rhoflex GL, GW, UltraGard Gold, Isolite E, ACFoam Composite, Rhoflex Composite, Fesco Foam Minimum 1" thick N/A N/A HP Recovery, Structodeck, Fiber Base, :high Density Fiberboard Minimum W'thick N/A N/A Dens Deck, Dens Deck Prime, Strata guard Minimum W' thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe Required over the insulations listed in Base Layer or optional over any of the insulations listed as Base or Top Layer: HP Recovery (for use over all insulation. types) Fiber Base (for use over polyisocyanurate, gypsum or perlite) Minimum Yz" thick N/A N/A Note: All layers of insulation and base sheet shall be simultaneously attached. See base sheet below for fasteners and density. Refer to Roof"mg Application Standard RAS 117 for insnlation attachment requirements. Insulation shall have preliminary attachment, prior to the installation of the roofing membrane. At an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Single and multiple layers of insulation can be attached to the deck with FAST Adhesive or OlyBond 500 BA. Vapor Retarder. (Optional) Any UL or FM approved vapor retarder applied to the roof deck or over a base layer of insulation. None. Barrier: 9 NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 11 of 15 Membrane: Deck: Fastening #1: Fastening #2: Fastening #3: Fastening #4: Surfacing: Maximum Design Pressure: 9 Sure-Seal Reinforced, FR Reinforced or Sure-Tough secured through the preliminarily attached insulation as specified below. Minimum 22 gage ASTM A653 Grade C Steel deck fastened to steel support at a maximum span of 6 feet o.c. Steel deck shall be fastened with minimum ITW BuiIdex Traxx/5 at a maximum spacing of 6 inches o.c. Side laps shall be fastened with Traxx/I at a maximum spacing of 24 inches o.c. Sure-Seal Metal Fastening Bars with Sure-Seal HP.X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 12" o.c. installed through the lap or through a RUSS strip in rows spaced maximum 6'-6" O.c. Maximum Design Pressure -45 psi (See General Limitation #7) Sure-Seal Metal Fastening Bars with Sure-Seal HP.X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 6" o.c. installed through the lap or through a RUSS strip in rows spaced maximum 9'-6" o.c. Maximum Design Pressure -52.5 psf (See General Limitation #7) Sure-Seal Metal Fastening Bars with Sure-Seal HP.X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 6" o.c. installed through the lap or through a RUSS strip in rows spaced maximum 6'-6" o.c. Maximum Design Pressure -67.5 psi (See General Limitation #7) Sure-Seal HP Fasteners with 2" Polymer Plates spaced 6" O.c. through the Sure- Tough Membrane in the lap in rows spaced maximum 9'_6" o.c. Maximum Design Pressure -52.5 psj. (See General Limitation #7) (Optional) A two-part surfacing consisting ofEM-8 Hypalon applied at the rate of I gal./I 50 ft2 and silica sand applied into the wet coating at a rate of 35 lbs.lsq. or two coats of Sure-Seal Acrylic Coating at a rate 1.5 gaVsq. per coat. See Fastening Options Above NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 12 of 15 Membrane Type: Single Ply, Thermoset, EPDM, Reinforced Deck Type 21: Steel, Insulated Deck Description: 18-22 ga. Steel. (See Deck Type noted below) System Type D(2): Membrane mechanically attached over preliminarily fastened insulation. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (fable 3) Density/fe One of the following covered with the boards listed in Top Layer or Base or Top Layer. Extruded or Expanded Polystyrene Minimum I" thick N/A N/A Perlite Minimum W' thick N/A N/A Base or Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ENRGY-2, ENRGY-3, PSI-25, H-Shield, AC Foam D, AC Foam III, Polyisocyanurate HP, IIP-W, IIP-H, Polyisocyanurate IIP-N, Multi-Max FA, Hytherm AP, UltraIM-D Iso/glas, ISO 95+ HF, RhoOex HF, ISO 95+GL, GW, RhoOex GL, GW, UltraGard Gold, Isolite E, ACFoam Composite, RhoOex Composite, Fesco Foam Minimum 1" thick N/A N/A lIP Recovery, Structodeck, Fiber Base, High Density Fiberboard Minimum ~"thick N/A N/A Dens Deck, Dens Deck Prime, Strataguard Minimum W'thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe Required over the insulations listed in Base Layer or optional over any of the insulations listed as Base or Top Layer: lIP Recovery (for use over all insulation. types) Fiber Base (for use over polyisocyanurate, gypsum or perlite) Minimum W' thick N/A N/A Note: All layers of insulation and base sheet shall be simultaneously attached. See base sheet below for fasteners and density. Refer to Roofing Application Standard RAS 117 for insulation attachment requirements. Insulation shall have preliminary attachment, prior to the installation of the roofing membrane. At an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Single and multiple layers of insulation can be attached to the deck with FAST Adhesive or OlyBond 500 BA. Vapor Retarder: (Optional) Any UL or FM approved vapor retarder applied to the roof deck or over a base layer of insulation. None. Barrier: 8 c> . ~~ NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 13 of 15 Membrane: Deck: Fastening #1: Fastening #2: Fastening #3: Fastening #4: Fastening #5: Surfacing: Maximum Design Pressure: 9 Sure-Seal Reinforced, FR Reinforced or Sure-Tough secured through the preliminarily attached insulation as specified below. Minimum 22 gage ASTM A653 Grade E Steel deck fastened to steel support at a maximum span of 6 feet o.c. Steel deck shall be fastened with minimum ITW Buildex Traxx/5 at a maximum spacing of 6 inches o.c. Side laps shall be fastened with Traxx/l at a maximum spacing of 30 inches o.c. Sure-Seal Metal Fastening Bars with Sure-Seal HP.X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 12" o.c. installed through the reinforced membrane in the lap or through a RUSS strip in rows spaced maximum 9'-6" o.c. Maximum Design Pressure -45 psi (See General Limitation #7) Sure-Seal Metal Fastening Bars with Sure-Seal HP-X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 6" o.c. installed through the reinforced membrane in the lap or through a RUSS strip in rows spaced maximum 9'-6" o.c. Maximum Design Pressure -60 psi (See General Limitation #7) Sure-Seal Metal Fastening Bars with Sure-Seal HP-X Fasteners or ST Fastening Bar With Sure-Tite Fasteners spaced 6" o.c. installed through the reinforced membrane in the lap or through a RUSS strip in rows spaced maximum 6'-6" o.c. Maximum Design Pressure-75 psi (See General Limitation #7) Sure-Seal HP fasteners Polymer Plates 6" o.c. installed through the reinforced membrane in the lap or through a RUSS strip in rows spaced maximum 9'-6" o.c.. Maximum Design Pressure -52.5 psj. (See General Limitation #7) Sure-Seal HP Fasteners and 2" Polymer Plates spaced 6" o.C. through Sure-Tough Membrane in the lap in rows spaced maximum 9' -6" o.c. Maximum Design Pressure -60 psi (See General Limitation #7) (Optional) A two-part surfacing consisting ofEM-8 Hypalon applied at the rate of 1 gal./150 ft2 and silica sand applied into the wet coating at a rate of351bs.lsq. or two coats of Sure-Seal Acrylic Coating at a rate 1.5 gaVsq. per coat. See Fastening Options Above NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 14 of 15 STEEL DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 137, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage attached with 5/8" puddle welds with weld washers at every flute with maximum deck spans of 5 ft. O.c. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs.lsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of ]2 Ibs.lsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 IbE insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofmg Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS III and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE &) NOA No.: 06-0403.05 Expiration Date: 06/28/11 Approval Date: 06/29/06 Page 15 of 15 Florida Building Code Online Product Approval USER: Public User Page 1 of3 I Publications Product Approval Menu> Product or Application Search> Application List> Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer AddressjPhonejEmail Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative AddressjPhone/Email Category Subcategory Compliance Method Certification Agency FL5851 New 2004 Approved YKK AP America 332 Firetower Road Dublin, GA 31021 (478) 277-2549 chrismoody@ykk-api.com Chris Moody chrismoody@ykk-api.com Jose I Archila 332 Firetower Road Dublin, GA 31021 josea rchila@ykk-api.com Exterior Doors Swinging Exterior Door Assemblies Certification Mark or Listing Miami-Dade BCCO - CER http://www .floridabuilding.orglpr/pr _ app _ dt1.aspx?param=wGEVX QwtDqt%2bOlhBh 1 Pj... 12/4/2007 Florida Building Code Online Page 2 of3 Referenced Standard and Year (of Standard) Standard TAS 202 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted Date Validated Date Pending FBC Approval Date Approved 11/18/2005 11/18/2005 11/28/2005 12/06/2005 Summary of Products FL# Model, Number or Na~ription 5851.1 1200 IIAluminum Entrance Door Limits of Use (See Other) Certification Agency Ce Approved for use in HVHZ: Installation Instruction Approved for use outside HVHZ: PTID 5851 I 20d,35d.51 Impact Resistant: Verified By: Design Pressure: +/- Other: Approved for use in HVHZ under NOA# 03-0801.05 and 03-0801.06. Design Pressures listed in NOA shall be divided by 1.33 to comply with 2004 FBC or be varified by a Florida PE. 5851.2 35DH Aluminum Entrance Door Limits of Use (See Other) Certification Agency Ce Approved for use in HVHZ: Installation Instruction Approved for use outside HVHZ: Verified By: Impact Resistant: Design Pressure: +/- Other: Approved for use in HVHZ under NOA# 03-0916.03. Design Pressures listed in NOA shall be divided by 1.33 to comply with 2004 FBC or be varified by a Florida PE. Back I I Next DCA Administration Department of Community Affairs http://www.floridabuilding.org/pr/pr_app _ dtl.aspx?param=wGEVXQwtDqt%2bOlhBh 1 Pj... 12/4/2007 Florida Building Code Online Page 3 of3 Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 @ 2000-2005 The State of Florida. All rights reserved. CODvriQht and Disci. Product Approval Accepts: =1iI~. http://www.f1oridabuilding.org/pr/pr _ app _ dtl.aspx?param=wGEVXQwtDqt%2bOlhBhl Pj... 12/4/2007 YKK a~ 200, 350 & 500 ENTRANCES ~ \ Installation Manual \ / / I I @2004 YKK AP America Inc. is a subsidiary of G YKK Corporation of America. 200, 350, 500 Entrances YKK a~ TABLE OF CONTENTS Installation Notes ....................................... Page ji Cut Down Transom Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 1 Fabricate Frame For Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 1 Offset Pivot Frame Installation ............................ Page 2 Butt Hinge Frame Installation ............................. Page 3 Center Pivot Frame Installation. . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 4 Calculate Transom Glass Size. . . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 5 Install Overhead Concealed Closer ........................ Page 6 In Offset Pivot and Butt Hinge Frames Install Optional Panic Strike .............................. Page 6 Install Optional Bottom Offset Pivot. . . . . . . . . . . . . . . . . . . . . . .. Page 6 Glaze The Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. Page 7 Install Smart Series Push/Pull Hardware . . . . . . . . . . . . . . . . . . .. Page 7 Install Offset Pivot Door Into Frame . . . . . . . . . . . . . . . . . . . . . . .. Page 8 Install Butt Hinge Door Into Frame . . . . . . . . . . . . . . . . . . . . . . . .. Page 8 Install Center Pivot Door Into Frame ....................... Page 9 Adjust Weather Astragal For Pair of Doors . . . . . . . . . . . . . . . . .. Page 9 Install Door Sweeps ..................................... Page 10 Effective Date: July 15, 2004 Page-i YKK a~ 200, 350, 500 Entrances Installation Notes 1. Do not drop, roll or drag boxes of aluminum framing. Move and stack boxes with proper support to prevent distortion. If fork lifts are used be especially careful about striking the boxes when lifting or moving. 2. Store in a dry, out of the way area. If rain exposure, condensation or any water contact is likely, then all packaging material should be removed. Wet packaging materials will discolor and may stain aluminum finishes and paints. 3. All materials should be checked for quantity and quality upon receipt, YKK AP must be notified immediately of any discrepancies in shipment. Check to make sure that you have the required shims, sealants, supplies and tools necessary for the installation. 4. Carefully check the openings and surrounding conditions that will receive your material. Remember, if the construction is not per the construction documents, it is your responsibility to notify the general contractor in writing. Any discrepancies must be brought to the general contractor's attention before you proceed with the installation. 5. Gather your shop drawings, materials, packing list and this installation manual. Carefully review parts location, the sequence it goes therein when you glaze it and how you seal it. Installation instructions are of a general nature and may not cover every condition you encounter. The shop drawings and/or installation manuals were prepared specifically for the product. 6. Any material substitutions must be of equal or greater quality. 7. Make certain that material samples have been sent for compatibility testing for all manufacturer's sealants involved. Make certain that sealants have been installed in strict accordance with the manufacturer's recommendations and specifications. 8. Remember to isolate, in an approved manner, all aluminum from uncured masonary or other incompatible materials. 9. System-to-structure fasteners are not supplied by YKK. Fasteners called out on shop drawings are to indicate minimum sizes for design loading. 10. Entrances are to be installed plumb, square, level and true. 11. If any questions arise concerning YKK products or their installation, contact YKK AP for clarification before proceeding. 12. YKK store front and/or curtain wall framing is typically completed before drywall, flooring and other products that may still be in process. Take the extra time to wrap and protect work that you have proudly produced, because no one else will. 13. Cutting tolerances are plus zero, minus one thirty second unless otherwise noted. 14. Check our website, www.ykkap.com. for the latest installation manual update prior to commencing work. Page-ii Effective Date: July 15, 2004 200, 350, 500 Entrances YKK a~ STEP 1 CUT DOWN TRANSOM FRAME (For non-transom frames, proceed directly to Step 3) Measure the height of each masonry opening that is to receive a door frame. If there are several different frame heights, it will be necessary to label each frame. -Deduct 3/8" from the height of the masonry opening to determine the frame size. -Slide the transom glazing pocket up so that it is flush with the end of the frame. -Mark the frame height on the frame jambs by measuring up from the bottom of the frame. See Detail 1. -Cut the frame and the transom glazing pocket. -Slide the transom glazing pocket back down into position. See Detail 2. Transom Glazing Pocket DETAIL 2 DETAIL 1 Mark Frame Height STEP 2 FABRICATE FRAME FOR HEADER FACE 6~8 II I I II II I I II II I I II -Measure down from the top of the frame dimension "A", see the table below. -Mark the spot on each "V-Groove" for the holes required to attach header. -Drill a 0.236" diameter hole (#8 drill bit) through both the web and the front of the jamb, at each location marked. See Detail 3. -Drill 1/2" diameter access holes in web only, centered on the first holes drilled, to permit the head of the fasteners to pass through the web. <( o 0.236" (Web & Face) o 0.500" (Web Only) Member Dimension A 1-3/4" Header 1-9/16" 2" Header 1-13/16" DETAIL 3 I I I I I I ~ I V-Groove I I I Effective Date: July 15, 2004 Page-1 YKK a~ 200, 350, 500 Entrances STEP 3 OFFSET PIVOT FRAME INSTALLATION -Remove from the door carton, through the cut-out provided, the offset pivot frame portion packages. Top Pivot Package: Accessories: (1) top pivot frame portion E1-0303. Screws: (3) FM-1206 finish to match frame. Bottom Pivot Package: Accessories: (1) bottom pivot frame portion: E1-0300(RH), E1-0301(LH). (1) Plastic anchor plug. Screws: (2) FM-1206 finish to match frame. (2) FM-1206 mill finish. -Remove from the frame carton the frame accessory package: Singles and pairs: Accessories: (3) plastic anchor plugs, (2) setting blocks for transom lite: E2-0019 for 1/4" glass or E2-0020 for 1" glass. Screws: (3) FC-1228, (4 or 8) PC-1216 (8 for transom). Single door frames only: Accessories: (1) threshold clip E1-0307. Screws: (2) FM-1206 to match frame, (2) FM-1206 mill finish. -Attach bottom pivot and threshold clips to frame. -Attach top pivot frame portion to the transom bar. -Assemble frame as shown. See Detail 4. PC-1216 ~- Install the frame into the opening: -Anchor bottom pivot to the opening. -Shim if required. -Attach the threshold to the frame set in bed of sealant. -Shim and anchor frame so that it is plumb, square, level, and true. -Caulk the perimeter of the frame with a quality sealant. '- Jamb ~ad T~ Glazing Pocket Transom Glass Stop Glaze the transom lite: (See Page 5 to calculate Transom Glass Sizes) -Snap into place the interior transom glass stop. -Install interior glazing gasket in the transom. -Install setting blocks at quarter points. -Carefully install the transom lite. -Snap into place the exterior transom glass stop. -Install exterior gasket. DETAIL 4 E1-0307 Page-2 Effective Date: July 15, 2004 200, 350, 500 Entrances YKK a~ STEP 3 BUTT HINGE FRAME INSTALLATION -Remove from the door carton, through the cut-out provided, the accessory package. Accessories: (2) threshold clips E1-0307, (3) plastic anchor plugs, (2) setting blocks for transom lites: E2-0019 for 1/4" glass or E2-0020 for 1" glass. Fasteners: (3) FC-1228 FHSMS, (8) FM-1206 (4 to match frame & 4 mill finish, and (4) or (8) PC-1216 fasteners (8 for transom frames). -Attach the threshold clips to the frame. -Assemble frame as shown. See Detail 5. Install the frame into the opening: -Attach the threshold to the frame set in bed of sealant. -Shim and anchor frame so that it is plumb, square, level, and true. -Caulk the perimeter of the frame with a quality sealant. '- Glaze the transom lite: (See Page 5 to calculate Transom Glass Sizes) -Snap into place the interior transom glass stop. -Install interior glazing gasket in the transom. -Install setting blocks at quarter points. -Carefully install the transom lite. -Snap into place the exterior transom glass stop. -Install exterior gasket. Jamb Transom Glass Stop Backup Plate (Factory Installed) DETAIL 5 E1-0307 Effective Date: July 15, 2004 Page-3 YKK a~ 200, 350, 500 Entrances STEP 3 CENTER PIVOT FRAME INSTALLATION -Remove from the frame carton the accessory package: Accessories: (2) Threshold clips, (3) plastic anchor plugs, (1) transom bar/closer shear block (2 for pair of doors), (1) transom bar shear block: E1-0317 for 41/2" frames or E1-0326 for 4" frames for single doors, (1) closer anchor clip, (1) bottom pivot assembly, (2) setting blocks for transom lites: E2-0019 for 1/4" glass or E2-0020 for 1" glass. Fasteners (8) FM-1206 and (3) FC-1228 to attach threshold clips and threshold, For Frame: (4) PC-1216 to attach headers (transom frames only), (2) PC-1228 to attach the E1-0326 or E1-0317 and (2) FC-1008 to attach the T-Bar (single door frames only). Fasteners (2) 1/4-20 x 1/2" HHMS bolts with lock washers, (3) 1/4-20 x 1/2" PHMS bolts, For Closer: (2) 1/4-20 x 1-1/4" FHMS, and (6) FM-1006. Note: Last five items doubled for frames for pairs of doors. -Assemble the threshold clips to the frame. -Asemble the bottom pivot(s) to the threshold. -Assemble frame as shown. See Detail 6. DETAIL 6 Install the frame into the opening: -Attach the threshold to the frame set in bed of sealant. -Shim and anchor frame so that it is plumb, square, level, and true. -Caulk the perimeter of the frame with a quality sealant. -Install the overhead door closer(s). See Detail 7 and the instructions in the closer box. -Attach cover plate(s). Glaze the transom lite: (See Page 5 to calculate Transom Glass Sizes) -Snap into place the interior transom glass stop. -Install interior glazing gasket in the transom. -Install setting blocks at quarter points. -Carefully install the transom lite. -Snap into place the exterior transom glass stop. -Install exterior gasket. DETAIL 7 E1-0317 PC-1228 FC-1008 .~~( / E1-0307 / Center Pivot 1/4"-20 x 1-1/4" FHMS 1 Page-4 Effective Date: July 15, 2004 200, 350, 500 Entrances YKK a~ Calculate Transom Glass Sizes: o ..J e- O) c 'c Ql a. o :E .21 >. III a DETAIL 8 1/4" Glazing Shown 1" Glazing Similar Daylight Opening (D.L.O.) II ** 1/4" Glazing Pocket = 1/8" 1" Glazing Pocket = 1/2" * Single Glazing (Offset Pivot) = 13/16" Single Glazing (OHCC) = 15/16" Insulated Glazing = 1" Transom Glass Size Formulas TYPE YES 40 FS/FI YES 45 FS/FI Width for Single Glass D.L.O. +(plus) 5/8" D.L.O. +(plus) 5/8" Height for Single Glass D.L.O. +(plus) 5/8" D.L.O. +(plus) 5/8" Width for Insulated Glass D.L.O. +(plus) 7/8" D.L.O. +(plus) 7/8" Height for Insulated Glass D.L.O. +(plus) 7/8" D.L.O. +(plus) 7/8" Note: Above transom glass sizes are for YES 40 and YES 45 frames only; for other frames refer to shop drawings or contact YKK AP. Effective Date: July 15, 2004 Page-5 YKK a~ 200, 350, 500 Entrances STEP 4 (OPTIONAL) INSTALL OVERHEAD CONCEALED CLOSER IN OFFSET PIVOT & BUTT HINGE FRAMES -Assemble the frame by first attaching the transom bar/closer shear block to the pivot jamb of the frame. -Complete the assembly and installation of the frame following the standard installation instructions. -Install the overhead concealed closer into the frame. -Attach the cover plate and the offset arm. -The top door rail has been routed out to clear the offset arm of the closer. -Locate the arm cover package that is in the frame box and attach it to the bottom of the transom bar with #10-32 x 2" fasteners provided (three for singles and four for pairs). See Detail 9. DETAIL 10 STEP 6 (OPTIONAL) INSTALL BOTTOM OFFSET PIVOT, E1-0341 Offset pivot door frames that do not have a threhold will require bottom offset pivot, E1-0341, which may also be used as a replacement bottom pivot. -Locate the bottom pivot package taped to the door. -Anchor the pivot to the concrete using (3) FC-1228 fasteners and plastic plugs. -Shim as required. See Detail 11. Shear Block For OHCC Transom Bar For OHCC DETAIL 9 #10-32 x 2" PHMS STEP 5 (OPTIONAL) INSTALL STRIKE FOR STANDARD EXIT DEVICE -Locate the strike package taped to the door. -The package will contain: (1) Strike. (3) Shims. (4) Screws. -Install the strike according to Detail 10. -Install shims as required. FC-1228 #12 x 1-3/4" n , DETAIL 11 E1-0341 Bottom Pivot Page-6 Effective Date: July 15, 2004 200, 350, 590 Entrances YKK a~ STEP 7 GLAZE THE DOOR Heel CD Install interior glass stops. -Trim glazing gasket leaving 1/8" excess at each end. -Install the vertical glass stop first by engaging the heel <D first then snapping in the toe @. See Detail 12. -Center the horizontal glass stops and install. -Carefully install the door lite onto the factory installed corner blocks. -Install the exterior glass stops repeating the instructions listed above. DETAIL 12 STEP 8 INSTALL SMART SERIES PUSH/PULL HARDWARE Attach pull handle: -Remove from the door carton the push/pull hardware and accessory package. -Fasten the pull handle to the lock stile with the 2-1/2" shoulder bolt at the top and with the 2-3/4" oval head machine screw at the bottom. Make sure the washer is properly seated under the screw head. Attach push bar: -Attach the end cap to the pivot stile with the FM-2512 3/4" machine screw. -Insert the straight end of the push bar into the end cap and swing the curved end onto the shoulder bolt head. Tighten the set screws at each end of the push bar using a 1/8" Allen wrench. See Detail 13. Note: For center pivot doors, push bars are installed on both sides of the doors; attach shoulder bolts on both stiles and follow the instructions above to attach push bars. Repeat steps for the other side. End Cap Set Screw Lock Stile Pull Handle ........ 1/4"-20 x 2-1/4" _~ Shoulder Bolt Set Screw '"",, cs:::: FM-2512 ~ 1/4"-20 x 3/4" Flat Head MS 1/4"-20 x 2-3/4" Oval Phillips MS with Washer Pivot Stile DETAIL 13 Viewed from Interior Effective Date: July 15, 2004 Page-7 YKK a~ 200, 350, 500 Entrances STEP 9 INSTALL OFFSET PIVOT DOOR INTO FRAME -Set the door down onto the bottom pivot of the frame. -Compress the retractable pivot pin in the top pivot and set the door up into position so the pivot pin engages the frame pivot. -Check the alignment of the door. -Align the stile opposite the pivot stile by turning the screw located in the top rail: Clockwise to raise the corner. Counter-clockwise to lower the corner. See Detail 14. -Align the pivot stile by adjusting the screw in the bottom pivot. -Unscrew the cap on top of the pivot and adjust the screw inside the pivot with a 3/16" Allen wrench: Clockwise to raise the corner. Counter-clockwise to lower the corner. -Replace the cap on top of the pivot. See Detail 15. @ Pivot Stile Pivot Stile 4- 4- n 4- ~ 4- DETAIL 14 STEP 9 INSTALL BUTT HINGE DOOR INTO FRAME -Remove from the door carton the package of eight fasteners that will attach the butt hinges to the backup plates in the frame. -Carefully align the holes in the butt hinge with the holes in the back up plates and fasten the door to the frame. Completely support the door during this step. -Check the alignment of the door with the frame. -Adjust the alignment of the door by turning the screw located in the top rail: Clockwise to raise the corner. Counter-clockwise to lower the corner. See Detail 14. DETAIL 15 Page-8 Effective Date: July 15,2004 200, 35'0, 500 Entrances YKK a~ STEP 9 INSTALL CENTER PIVOT DOOR INTO FRAME -Remove from the package taped to the door the end cap and bolts for the top arm assembly. -Remove from the pivot stile the two endcaps. -Check the alignment of the top arm: The arm must be centered in the top rail. See Detail 16. -For non-hold open closers; slow the closer speed. -Carefully rotate the pivot of the closer 900 to the exterior of the frame to install the door. -Set the door down onto the bottom pivot and slide the top arm around the top pivot of the closer. -Install the end of the top arm and the end caps of the door. -Check the bottom corner of the door with the frame. -Adjust the bottom corner of the door by turning the screw located in the top rail of the door: Clockwise to raise the corner. Counter-clockwise to lower the corner. See Detail 14. h Arm End Cap / Top Arm -0'8 @ '- ~~ ~ 1" ~Olt ""- Stile End Cap Top Rail DETAIL 16 -Adjust the closing and latch speed of the closer. STEP 10 ADJUST WEATHER ASTRAGAL FOR PAIR OF DOORS -Adjust the weather astragal by turning the adjustment screws located along the meeting stile cover of the active leaf: Clockwise to increase the distance between leafs. Counter clockwise to reduce the clearance between leafs. See Detail 17. E9-0332 Meeting Stile Cover E9-0329 Active Leaf DETAIL 17 Effective Date: July 15, 2004 Page-9 YKK a~ 200, 350, 500 Entrances STEP 11 (OPTIONAL) INSTALL DOOR SWEEP -Door sweeps help the weathering performance of the door and are designed to be attached to the interior face of the bottom rail. -Transfer the location of each slot in the door sweep base, E9-0347, to the interior surface of the bottom rail: -Center the door sweep base on the bottom rail of the door. -Align the bottom edge of the door sweep base with the bottom edge of the bottom rail. -Mark the center of each slot on the bottom rail. -Drill a 0.141" diameter hole (#28 drill bit) at each location marked. -Attach the door sweep base to the bottom rail with four PC-0808 fasteners; do not completely tighten the fasteners. Check the contact of the door sweep gasket, E2-0067, with the threshold. The door sweep gasket must make full contact with the threshold to obtain the full benefit of the door sweep. -Tighten all of the door sweep fasteners. -Use a wood block and mallet to snap the door sweep cover, E9-0348, onto the base. See Detail 18. E9-0347 PC-080a E9-0348 E9-0347 DETAIL 18 Viewed from Interior E2-0067 Page-10 Effective Date: July 15, 2004 G YKK AP America Inc. 7680 The Bluffs Suite 100 Austell, Georgia 30168 www.ykkap.com Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs FLA/COM 2004 v2.5 -- Form 400A-2004 Method A: Whole Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: Napa Owner: Napa Auto Parts Address1: ~ Gall Boulevard Address2: Description: Zephyrhills Type: Retail Jurisdiction: ZEPHYRHILLS, PASCO COUNTY, FL (611600) Cond Area: 7800 SF Cond & UnCond Area: 7800 SF No of Storeys: 1 Area entered from Plans 7800 SF Permit No: 0 Max Tonnage 5 If different, write in: City: State: Zip: Class: Zephyrhills Florida 33541 New Finished building 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 Compliance Summary Component Design Criteria Result Gross Energy Use 11,118.2 12,070.1 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS None Entered PIPING SYSTEMS None Entered Met all required compliance from Check List? Y esIN oINA IMPORTANT NOTE: An input report of this design building must be submitted along with this Compliance Report. 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 2 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: :),I~~lq ~O- ~ Building Official: -iJ' l~~ Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: MITCHELL M. DEUTSCH Reg No: 93755 Electrical Designer: 1. DOUGLAS RIDDLE II Reg No: 40423 Lighting Designer: J. DOUGLAS RIDDLE II Reg No: 40423 Mechanical Designer: JUSTIN R. HARDY Reg No: 67084 Plumbing Designer: JUSTIN R. HARDY Reg No: 67084 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signedlsealed plans. ^ J')J:: f \ . }H - ')- J.C-l.") / j v 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 3 Project: Napa' Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) Building End Uses Design Reference Total 92.12 100.00 $11,118 $12,070 ELECTRICITY (Mptu/k 92.~~ 100.00 Wh/$) 220163"'~" 239012 $11,118 $12,070 AREA LIGHTS 30.13 37.02 72027 88486 $3,637 $4,469 MISC EQUIPMT 21.00 21.00 50178 50178 $2,534 $2,534 PUMPS & MISC 0.01 0.01 26 26 $1 $1 SPACE COOL 29.25 28.78 69902 68788 $3,530 $3,474 VENT FANS 11.73 13.19 28030 31534 $1,416 $1,592 Credits & Penalties (if any): Modified Points: = 92.12 I PASSES I 12/5/2007 EnergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 4 Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) External Lighting Compliance Description Category Allowance Area or Length ELP A CLP (WlUnit) or No. of Units (W) (W) (Sqft or ft) Ext Light 1 Plaza Areas 0.20 7,800.0 1,560 170 Design: 1530 (W) I PASSES I Allowance: 1560 (W) Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- In (sq.ft) Tasks CP CP ance Napa ,001 Sales Area 7,800 1 7 4 PASSES I PASSES I Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) System Report Compliance AHU-l Split System Constant Volume Air Cooled No. of Units thru 4 Split System < 65000 Btulhr 4 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria Iiance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume I PASSES I 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 5 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance I None I Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance I None I Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] I None I 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 6 Project: Napa Title: Zephyrhills Type: Retail (WEA File: Tampa.tmy) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met D System 407.1 HV AC Load sizing has been performed D Ventilation 409.1 Ventilation criteria have been met D ADS 410.1 Duct sizing and Design have been performed D T&B 410.1 Testing and Balancing will be performed D Motors 414.1 Motor efficiency criteria have been met D Lighting 415.1 Lighting criteria have been met D O&M 102.1 Operation/maintenance manual will be provided to owner D RooVCeil 404.1 R-19 for Roof Deck with supply plenums beneath it D Report 101 Input Report Print-Out from EnergyGauge FlaCom attached? D 12/5/2007 EnergyGauge Summit v3.1 0 incorporating Florida Energy Code Version - FLAlCOM 2004 v2.5 7 EnergyGauge Summit v3.10 INPUT DATA REPORT Proiect Information Project Name: Napa Orientation: East Project Title: Zephyrhills Address: 6855 Gall Boulevard Building Type: Retail Building Classification: New Finished building State: Florida Zip: 33541 No.of Storeys: GrossArea: 7800 SF Owner: Napa Auto Parts Zones No Acronym Description Type Area Multiplier Total Area [sf! [sf! I Napa Napa Auto Parts CONDITIONED 7800.0 I 7800.0 D Zephyrhills Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf! [cf! In Zone: Napa I Napa Napa Auto Parts Sales Area 50.00 156.00 20.70 I 7800.0 161460.0 D Zephyrhills Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [WI Ctrl pts In Zone: Napa In Space: Napa I Recessed Fluorescent - General Lighting 3 59 177 Programmable timer I 0 No vent without Daylighting 2 Recessed FI uorescent - General Lighting 2 59 118 Programmable timer I 0 No vent without Daylighting 3 Recessed Fluorescent - General Lighting 4 113 452 Programmable timer I 0 No vent without Daylighting 4 Recessed Fluorescent- Displayl Accent 2 113 226 Programmable timer I 0 No vent Lighting without Daylighting 5 Recessed Fluorescent - Displayl Accent 17 59 1003 Programmable timer I 0 No vent Lighting without Daylighting 6 Recessed Fluorescent - General Lighting 108 59 6372 Programmable timer I 0 No vent without Daylighting 7 Recessed Fluorescent - General Lighting I 162 162 Programmable timer I 0 No vent without Daylighting 8 Recessed Fluorescent - General Lighting 13 324 4212 Programmable timer I 0 No vent without Daylighting 9 Recessed Fluorescent - General Lighting 4 460 1840 Programmable timer I 0 No vent without Daylighting 12/5/2007 EnergyGauge Summit v3.10 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] (Btulbr. sf. F) Capacity [Ib/cf] [h.sf.FlBtu] [Btu/sf.F] In Zone: Napa I Front Store East 0.75 in. stucco, 50.00 20.70 I 1035.0 East 0.0838 11.224 50.24 11.9 D 2"styro,8"CMU,lx2 x24"oc,airspace,0.5" gyp 2 Rear Store West 0.75 in. stucco, 50.00 20.70 I 1035.0 West 0.0838 11.224 50.24 11.9 D 2"styro,8"CMU,lx2 x24"oc,airspace)O.5" gyp 3 Side Store North 0.75 in. stucco, 156.00 20.70 I 3229.2 North 0.0838 11.224 50.24 11.9 D 2"styro,8"CMU,lx2 x24"oc,airspace,0.5" gyp 4 Side Store South 0.75 in. stucco, 156.00 20.70 I 3229.2 South 0.0838 11.224 50.24 11.9 D 2 "styro,8"CMU, I x2 x24"oc,airspace,0.5" gyp Windows No Description Type Shaded U SHGC Vis.Tn W H (Effec) Mult Total Area [Btulbr sf F) 1ft] [ft) iplier [sf] In Zone: Napa In Wall: Front Store East I East Window User Defined No 1.2500 0.70 0.58 12.00 14.00 I 168.0 D In Wall: Side Store North I North Window User Defined No 1.2500 0.70 0.58 23.00 12.00 I 276.0 D Doors No Description Type Shaded? Width H (Effec) Multi Area Condo Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btulbr. sf. F) [Ib/cf] [Btu/sf. F] [h.sf.FlBtu] In Zone: Napa In Wall: Rear Store West I West Door Metal No 8.00 8.00 I 64.0 0.0957 16.80 0.76 10.45 D siding/RIIBattlO.5 "Gyp 2 West Door 2 Metal No 7.00 3.00 I 21.0 0.0957 16.80 0.76 10.45 D siding/RIIBattlO.5 "Gyp Roofs No Description Type Width H (Effec) Multi Area Tilt Condo Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btulbr. Sf. F) (Btulsf. F) [Ib/cf] [h.sf.FlBtu] In Zone: Napa I Roof Mtl Bldg RooflR-19 156.00 50.00 1 7800.0 0.00 0.0492 1.34 9.49 20.3 D Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btulbr sf F) [ft] [ft) [Sf] [Sf] In Zone: In Roof: D Floors No Description Type Width H (Effec) Multi Area Condo Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btulbr. sf. F) (Btu/sf. F) [Ib/cf] [h.sf.FlBtu] In Zone: Napa 12/5/2007 EnergyGauge Summit v3.10 2 Floor I ft. soil, concrete floor, carpet and rubber pad 156.00 50.00 7800.0 0.1745 54.00 108.00 5.73 D Systems ABU-t tbru 4 Split System Constant Volume Air Cooled Split No. Of Units 4 System < 65000 Btu/br Component Cateeorv Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btulh Cooling 60000.00 13.00 8.00 D Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1000.00 0.80 D Constant Volume) Plant Equipment Category Size Inst.No Eff. IPLV U Water Heaters W-Heater Description Capacit~ap.Unit I/PRt. EfficienC} Loss 0 Ext-Lighting Description Category No. of Watts per ArealLen/No. of units Control Type Wattage Luminaires Luminaire [sf/ftlNo) [WI I Ext Light I Plaza Areas 9 170 7800.00 Astronomical Timer Co 1530.00 0 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F) [ Btu-inlh.sf.F) [in) [in) D Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btulh.sf.F) ASHULTntAllFr User Defined I 1.2500 0.7000 0.5800 D m Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHea Used [h.sf.F IBtu) [ft] [Btulh.ft.F) [Ih/cf] t 187 Matll87 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 D BOARD,l/2IN 178 Matll78 CARPET W/RUBBER PAD Yes 1.2300 D 265 Matl265 Soil, I ft No 2.0000 1.0000 0.5000 100.00 0.2000 D 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 D 267 Matl267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 D 215 Matl215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 D 2IN, 105 Matll05 CONC BLK HW, 8IN, No 1.1 002 0.6667 0.6060 69.00 0.2000 D HOLLOW 256 Matl256 WOOD, SOFT, 1-1I2IN No 1.8939 0.1250 0.0660 32.00 0.3300 D 12/5/2007 EnergyGauge Summit v3.10 3 12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 0 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 0 4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 0 94 Matl94 BUlL T-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 0 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F) [Btu/sf.F) Ilb/cll (h.sf.FlBtu) 1010 0.75 in. stucco, No No 0.08 11.22 50.24 11.9 0 2 "styro,8"CMU, I x2x24"oc,airspace,0. 5"gyp Layer Material Material Thickness Framing No. 1ft) Factor I 267 0.75" stucco 0.0625 0.000 0 2 187 GYP OR PLAS BOARD,l/2IN 0.0417 0.000 0 3 215 POLYSTYRENE, EXP., 2IN, 0.1667 0.000 0 4 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.000 0 5 256 WOOD, SOFT, 1-1/2IN 0.1250 0.000 D No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F) Ilb/cll Ih.sf.F IBtu) 1020 Metal siding/RIIBattlO.5"Gyp No No 0.10 0.76 16.80 10.5 D Layer Material Material Thickness Framing No. (ft] Factor I 4 Steel siding 0.0050 0.000 D 2 12 3 in. Insulation 0.2500 0.000 D 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 D No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F) [Btu/sf.F) Ilb/cll (h.sf.FlBtu) 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 0 Layer Material Material Thickness Framing No. 1ft) Factor I 94 BUlL T -UP ROOFING, 3/8IN 0.0313 0.000 D 2 23 6 in. Insulation 0.5000 0.000 D No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct (Btu/h.sf.F) [Btu/sf.F) Ilb/cll Ih.sf.FlBtu) 1057 I ft. soil, concrete floor, carpet and rubber No No 0.17 54.00 108.00 5.7 D pad Layer Material Material Thickness Framing No. 1ft) Factor I 265 Soil, I ft 2.0000 0.000 D 2 48 6 in. Heavyweight concrete 0.5000 0.000 D 3 178 CARPET W/RUBBER PAD 0.000 D 12/S/2007 EnergyGauge Summit v3.10 4 G-"e~-s ~ f~t e:+'a...ri~ ~~""-- 7'& 7~ 3G:.'2- D'2~Cj PH - 7'&7- 3C,p"z. - D.~%-a ~ A \ e -h-'o-", S @.. ~~'()ber~ro...rrcw (C~ AGENDA ~OARD OF ADJUSTMENT . SEPTEMBER~l, .2007 - 4 P.M. ry :BALL COUNCIL CHAMBERS 5335- 8TH STREET ROLL CALL PLEDGE OF ALLEGIANCE APPROVAL/CORRECTION OF MINUTES - Apr1l 10, 2007 1. Kevin Pruemer, eng1neer/representative of GreenbergFarrow for the NAPA project. Property 1S vacant parcel located between Golden Corral and Amer1wash. Var1ancerequest for the southeast corner of the proposed bU1lding to encroach a max~um of 2.5 feet and encompass plus/mi.nus 11 square feet of encroachment. BOARD 'OF ADJUSTMENT The Board of Adjustment meeting was held on Tuesday, September 11, 2007, at 4:00 p.m. in the Robert H. Johnson Council Chambers of City Hall. Roll call was taken. Present were members Wallace Reeves, Pat Besinger, Gary Hatrick, and William Poe, Sr. Staff present: City Attorney Joe Poblick, City Building Official Bill Burgess, and Senior Code Support Specialist Bobbie Swetland. The Pledge of Allegiance followed. Motion was made by Gary Hatrick to approve minutes of meeting of April 10, 2007. Seconded by Pat Besinger and passed unanimously. 1. Kevin Pruemer, engineer/representative of GreenbergFarrow for the NAPA Auto parts project. Property is vacant parcel located between Golden Corral and Ameriwash. Daniel W. Sharpe, Regional Manager/Senior Associate of GreebergFarrow was present as a representative for the NAPA Auto parts project and addressed the board regarding the variance request. Bill Burgess, Building Official stated the following highlights for the board's information. The project is required to have a 30 foot front setback & they had that for the majority of the building, but that the property line towards the south corner jogged the setback for a small area of 12 square foot of the building. He stated this amount is not a lot but it needed to be brought before the board to follow the formal process since the setback was not in total compliance. The hardship would be that if they slide the building back to meet compliance that several of the large oak trees and possibly some parking area would be lost. Also Burgess stated that this was an unusual situation with the jog in the property line. City Attorney Joe Poblick stated he concurred with staff's information and corrunents. After brief discussion, motion was made by Pat Besinger to approve the variance as requested. Seconded by Gary Hatrick and passed unanimously. Meeting adjourned at 4:10p.m. 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404601 4000 f: 404601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALLAS NEW JERSEY ST. PETERSBURG Letter of Transmittal December 6, 2007 To City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 813.780.0020 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 From Karla J. Sherrell We are sending you the following enclosures via Air Express - Standard for your use: Building Permit Review Copies/Sets Date Description Signed and sealed Construction Documents to include Civil, (for reference), Architectural, .mm......__~J~l:!~!Y-~~!LEI!l.!!'~J..r:!gL~~.~.h~r.:!~c::.~!,~!~c::.!ri~J,.~r.:!~..E.i~~..p.rQ!~c::.!iQI.:1.........mmm......_..___..________.._..___._.____ Signed and sealed Specification Manuals 3 3 3 Florida Product Approval Documentation for Overhead Doors, Hollow Metal Doors, EPDM !3gQL~.Y.l'>.!~!!'.!...G..~!::t.~.i.r.:!...yy~!!.~yl'>.!~.'!1~,__.~_~~~igr.P.Qg~.f.Qr..G..~!::t.~.i.r.:!.yy~~_~.Y.l'>.!~!!'~_____.___._.m___ Signed and Sealed Energy Calculations Letter of Authorization for Agent Completed Building Permit Application Message The above items are being submitted for your use in a Building Plan review for the above referenced project. If there is any additional information that you may need or if there are any questions or comments that you may have, please feel free to contact me at your convenience. Thanks in advance for all of your help & have a great weekend! If enclosures are not as noted, please contact sender Copies 01 Transmittal 02.06.06 P:\2007\200702080\999 General Correspondence\200702080 Transmittal from Karla J. Sherrell to City of Zephyrhills 2007-12-06A.doc @ @ u.s. AUTOMOTIVE PARTS GROUP A DIVISION OF GENUINE PARTS COMPANY 222 CHASTAIN MEADOWS CT., #100 KENNESAW, GEORGIA 30144-5806 4 GPC ~ 4NAPA~ City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 Date: December 5, 2007 Subject Notification of Agent for Owner Proposed NAPA Auto Parts Store 6855 Gall Blvd. Zephyrhills Florida To Whom It May Concern: This letter is to confirm that Greenberg Farrow, Inc. is authorized to act as an agent for Genuine Parts Company as it pertains only to the building plan reviews, approvals and permitting of our proposed NAPA Auto Parts Store located at 6855 Gall Blvd., Zephyrhills Florida Should there be any questions or concerns, please feel free to contact us. ~e'6~ Sonny Supan Manager of Store Design and Constructions Store Development Group Genuine Parts Company Telephone #: 770-541-4420 Email Address:SonnLSupan@genpt.com STATE OF GEORGIA COUNTY OF COBB Before me, the undersigned authority, a Notary Public in and for the State of Georgia, County of rDhb , on this ~~ day of ~.A'-1?~Q.A ,2007, personally appeared ~ H ~ ~ of> n ~lIo'\. ' known to me to be the person whose name is subscribed to the foregoing strument, and acknowledged to me that he executed the same as authorized by Genuine Parts Company, a Georgia corporation. ve~~...... / ~j.. N~tary Ublid(State of Georgia, ~:;;,"'" Print Name: e,~g(' c _Lo My commission expires ~ -I S -I ~ County (Notary Seal) Rebeccn Lock Noii:r~ PubHc Furlan County, Georgia My Commis:;ion Explre-a i,;.::;ch 15, 2010 . . U.S. AUTOMOTIVE PARTS GROUP A DIVISION OF GENUINE PARTS COMPANY 222 CHASTAIN MEADOWS CT., #100 KENNESAW, GEORGIA 30144-5806 4 ope ~ 4 NAPA~ City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 Date: December 5, 2007 Subject: Notification of Agent for Owner Proposed NAPA Auto Parts Store 6855 Gall Blvd. Zephyrhills Florida To Whom It May Concern: This letter is to confirm that Greenberg Farrow, Inc. is authorized to act as an agent for Genuine Parts Company as it pertains only to the building plan reviews, approvals and permitting of our proposed NAPA Auto Parts Store located at 6855 Gall Blvd., Zephyrhills Florida Should there be any questions or concerns, please feel free to contact us. ~I~ Sonny Supan Manager of Store Design and Constructions Store Development Group Genuine Parts Company Telephone #: 770-541-4420 Email Address:Sonny-Supan@genpt.com STATE OF GEORGIA COUNTY OF COBB Before me, the undersigned authority, a Notary Public in and for the State of Georgia, County of rD.b~ , on this ~~ day of ().o....l!P~QA , 2007, personally appeared ~ "'~ .c:;:.,.'f'o,,,,- ' known to me to be the person whose name is subscribed to the foregoing strument, and acknowledged to me that he executed the same as authorized by Genuine Parts Company, a Georgia corporation. ve~~~~ / ~~ N~tary ubli;J(State of Georgia, ~~hJ:, Print Name: e hg(' (' .. .L c My commission expires ~ -I S - I..., County (Notary Seal) Rebecca lock Notmv PubHc Ft~!on County, Goorgla My Commission Expires Milich 15, 2010 _t~ BUILDING CODE COMPLIANCE OFFICE (BCCO) . PRODUCT CONTROL DMSION MIAMI-DADE COUNlY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Cornell Iron Works, Inc. 100 Elmwood Avenue Mountaintop, PA 18707 Scope. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami-Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 14'_ 4" wide Roll-Up Door. ApPROVAL DOCUMENT: Drawing No. 96-399, dated 12/13/96, with last revision on 09/23/97, titled "Roll- Up Door", sheets 1 through 2 of2, prepared by Knezevich & Associates, Inc. signed and sealed by V. J. Knezevich, PE, bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been :filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NO A. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 00-0508.01 and, consists of this page, evidence page as well as approval document mentioned above. . The submitted documentation was reviewed by Can . 8 NOA No 03-0925.07 Expiration Date: October 23, 2008 Approval Date: November 13, 2003 Page 1 Cornell Iron Works. Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE A DRAWING: 1. Drawing No. %-399, titled "Roll-Up Door", sheet 1 and 2 of2, prepared by Knezevich & Associates, Inc., dated 12/13/96, with latest revision on 09123/97, signed and sealed by V. 1. Knezevich, PE. B TEST: 1. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test and Uniform Static Air Pressure on "T150 Steel Rolling Garage Door", prepared by Architectural Testing, Inc., report # 01-31475.01, dated 11/24/98, signed and sealed by A. N. Reeves, PE. 2. Test report on Large Missile Impact Test, Cyclic Wind Pressure Test and Uniform Static Air Pressure Test on "T150 Steel Rolling Garage Door", prepared by Architectural Testing Inc., report No. ATI-15775, dated 10/16/96, signed and sealed by A. N. Reeves, PE. C CALCULATIONS: 1. Calculations for roll-up Door, prepared by Knezevich & Associates, Inc., dated 07/07/97, sheets 1 to 10, signed and sealed by V. J. Knezevich, PE. on 07/18/97. 2. Calculations for Cornell Iron works, prepared by Knezevich & Associates, Inc., dated 12/18/96, sheets 1 to 7, signed and sealed by V. 1. Knezevich, PE on 12/18/96. D STATEMENTS: 1. Code Compliance letter issued by Knezevich & Associates, Inc. on 01/15/97, signed by V. 1. Knezevich, PE. 2. Test compliance letter Issued by Architectural. Inc. on 11/30/98, signed by A. N. Reeves, PE. 3. No financial interest letter issued by Knezevich & Associates, Inc. on 01/15/97, signed and sealed byV. J. Knezevich, PE. 4. No change letter issued by Cornell Iron Works, on 04/25/00 and signed by J. Walsh. 5. No change letter issued by Cornell Iron Works on 09/19/03 and signed by L. Greiner. E. MATERIAL CERTIFICATION: 1. Architectural Testing, Inc., Test Report No. 15775-10ftest per ASTM E8, of Galvanized Steel, dated 10/09/96, signed by A. N. Reeves, PE. "CO ~~~~ ~ C did F. FontPE Senior Product Control Examiner NOA No 03-0925.07 Expiration Date: October 23, 2008 Approval Date: November 13, 2003 E -1 GI!NERAl NOTll'!:5, 1, THIS ROLL-UP DOOR SYSTEM IS DESIGNED IN ACCORDANCE WITH' THE SOUTH FLORID.... BUlLC)(NG CODE, 1994 EDITION AS A I.ARGE MISSILE IMPACT RESISTANT SYSTEH. 2. POSITIVE ....ND NEGATIVE DESIGN PRESSURE CAI.(JJL.... TlDNS SHALL BE PERFORMED "OR SPECIf'IC JOBS IN ACCORDANCE WITH ASCf: 7-11I "MINIMUM DESIGN LOADS 'OR BUILDINGS AND OTHER STRUCTURES". WJND LOADS DETtRMINEO FOR OP!NINGS SHALl. BE LESS THAN OR EQUAL TO DOOR DESIGN PRESSURES NOTED BELOW. 3. PROOUCT MARKINGS SH....LL SE WITHIN 12" OF ONE END 01" THE DOOR WiTH.... MIN or ONE MARkiNG PER DOOR AND SHALL BE LABELED AS FOLLOWS: CORNELl. MOUNTAINTOP. P!NNSYLVANI.... DADE COUNTY PRODUCT CONTROL ....PPROVeD 4. ALL BOLTS AND WASHERS SHALL BE GALVANIZED OR STAINLESS STEEL WITH A MIoIIMUH Fy . 60 KSt TENSILE STRENGTH. 5. THE on AILS AND SP!Ctl"!CA TIONS SHOWN HEREtN REPRESENT THE PRODUCTS TEsno ,"OR IMPACT, CYCLIC ....ND UNfFORM STATIC AIR PRESSURE IN CONf'ORMANCE WITH DADE COUNTY PROTOCOLS PA 2Q1.202. AND 203. POSITIVE DESIGN l.OAD. 60 P.S.f. NEGA TlVE DESIGN LOAD. 60 P.S.F. 6. D!:SIGN BASED ON ARCHlTECTUR....l TESTING, INC. (YORK PENNSYLVANIA) TEST REPORT NO. ATI_15775. 1. SUPERIMPOSED LOADS ON THE JAMBS FADM THIS DOOR ARE DESIGNA TED AS ~~G~E~~V~~~~IN.D~~uT:lYCb~R8SU~~~~ ~:.rJc;~~~~~ ~~~I~iE:cr~~~~~~:~ONAL LOAD Vll, Vy AND eRACKfT LOADS SHOWN ON SHEET 2 Of 2. I. All WELDING SHALL ar PERfORMED BY QUALlf'IED WElOERS IN ACCOROANCE WITH A.W.$. SPECIFICATIONS, LATEST EDITION. ALL WELDING ELECTRODES SHALL CONfORM TO A.W.S. A5o1 GRADE (.10. 9. ANCHOR NOTES, A. EHBEDMENT l.ENGTH OOfS NOT INCLIAlE S Tucca PINISH. 8. ~~f~~~~~~~l~ B! INSTALLED IN ACCORDANCE WI MANUFACtURERS 10. DOOR HAY BE INSTALLED ON THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL. I ~jppmvm AS COMPLYING wntt. ~E ANCHOR CAPACITY FOR THIS ROLL-UP ODOR IS BASED ON 4000 PSI SCIUllI RORIM IIU!LDIIlQ CODE CONCRETE. PROVIDE 4~ MINIMUM EMBEDMENT FOR ALL ANCHORS. . :"(),.~,,m_ PRlIlUCT COfITROL DIVlSIOfl BUilDING COOECOIlPl.WtCE OffiCE (1"1' ~~ 'I' ,-l .21O-H R .250" (TYP J RU3I- tQ .37S~ CJ. @ WIND LOCK SCALE, HALF SIZE CAST MAllUBLE IRON GAl.VANIZED IN ACCORDANCE WITH ASTH A525 G90 .969" CD FLAT SLAT SCAI.!, HAlII SIZE 22 GAGE ASTM AIo.46 GRADE C MIN. 40 KSI STEEL DAlV.1N ACCORDANC! WITH A5TH A525 Ci90 7 ~..* MID-HOOD SUPPORT SPRING ADJUSTER COMPo CHAIN OPERATOR ,-. '" x~ J(O~EL~~:: :~OE EL~AL SCALE: 1\". ".0. SCALE: ~.. . 1'_0. 'V",""'.:/ .~~~~~~ -i.~7 ...... PRODUCT llliNEWill) ACC>1'T!J;CEN. ()O~ orof'~qu'- ~I :l'n~UJ>J UUlr~~11i}(:;~~Ir. J"l.~\.),' .,~i~':: .':"! 14'-4" MAX. OPENING WIDTH 14'-S" MAX. DIS T ANCE BETWEEN GUIDES PLAN VIEW SCALE, 1 1I..H. 1'~OM 09 3 97 13,29 ~ ~ . .. , 1.25" . Jl.E 275- f 1 i .1 r-----$------------l : -~:;ECT;;N-;;;------ . SUEL STRUCTURE )- I( 2" x 3/16" ST!!\. ANaL! ..HOLE 2.2S" r 17S" . 1\ J DIRECTION flOR I CONCRETE STRUCTURIE 311.16 x 1 ~~ HEX HEAD A)2' eOL T AND NUT _ 12" D.C. 4" x 3~" x 'K," STEEL ANGLE ~ 1 @)WIND LOCK GUIDE SCALE: HALF SIZE ASTM AU STEEL 4.00" II' J d ~.J E !:Ie. ~ ~~'I ~;ii 5 !iJ.,l . .. ~I!I ~ >lI1 i~!~ ; ". i~i~ : Yo. !l Jl ~i 1:1. z "" '" __.I! o -.U g 1Il:~I~ g; .~i~5 j I:hi ~ u:;i "< ~~ !II t. . Iii ~ Ii; Ii; i iH ". ,~ .........- 96-399 -1"".4 DISTANCE BETWEEN JAMBS POURED CONCRETE ~"-~~d ~'5 .012' ~.~~ NUT THREE ]115". GAL'IIANIZfC FTT.;I.~ RIVETS '.", I I @ll'f'1.~~O~M~~~~.) I '.'5" L tW i (DSlA. T --14' _ 5' 3.50. DISTANCE BETWEEN GUIDES 'A:' GUIDE ASSEMBL Y14000 P.51. CONCRETE) \OJ SCALE, '''. "-0" EXSITING STRUCTURE (STEEL OR CONCRETE) 24 GA STEEL lIFR'mliVi'FED If!\'HR9'llL FO~'H SCAEW~lV"yW G Vy ;l...;--,C'j'~>1J;;1E'iV111t "!-..',.,^"litr.t>>lI1DrIlIII 'Ill( . . 1114 POUNOS/FT. ~07 . .... f- . ~.. ...... @ ~~r~~Jr:1~OSED LOAD DIAGRAM Vy. '" 445 POUNDS/FT. ~~c~l:~~Ci~R~~~J,.HEO::~ AOTEJI~~gNT~E:EO:':~~~i' I!:CCENTRICITY IN~CA.TED. EXISTING STRUCTURE SHAL.L IS! CAPAI!5LIE 0" RESISTINQ THE FORCn SHOWN AND THf CORRESPONDING REACTIONS AND MOMENT AT THE STEEL OR CONCRETE STRUCTURE. 09 3' '3: 1 3/8-16 l( 1 'too HEX HEAD A325 BOLT AND NUT 11'12' D.C. @~+~~O~t).~~'~~.1 EXISTING STEE STRUCTURE MIN 1/1!l" THICK STEiL ~'~t~Ad ~25 3.0\:,1 ~.~D NUT m.5-f'.T" . I i , STEEL JAHB ~HANNe:L OR OTHER S TRU TURAL STEEL HEHBER MIN. lIS" THI K ST!EL ;t1r a~-,yJ;;.~LOT G)SLAT ---14' _ 5' 3.50" DISTANCE BETWEEN GUIDES @ 'O'f~~~O~~A f~f~~.l SLATeD --14' _ 5" 3.50" OlSTANCE BETWEEN GUIDES \..:.~~i6~O:SRfE~g~~ @ GUIDE ASSEMBLY ISTEEL STRUCTURE) SCALE' r. "-0" @ GUIDE ASSEMBLY CSTm STRUCTURE) SCALE, r. 1'-0" BRACKET WIDTH PLUS 1o!t~ '>I" I ,- I CONCRETE OR GROUTED CONCRETE I!lLDCK T..,O 3/11". THUNDERSTUD WEDGf .t.HCHORS WI 4" HIt EHlED. IN COHe. OR TWO ,,"'-. AAWL STUO ANCHORS WI 4" "'W. EHaED. IN GROUnD COHe. BLOCK PlACE" 3 Jl. ~ D.C. / TYPICAL WA~ AJtCHOA~E. ..AJI7........... o"! i.- SEE DETAil (6) (,!). OR(.g~ 1)Y' 'E" APPROVEII AS CDMPl VINe WITH THE \SI ~~~.,~~~P..sUPPORT DETAILl'RODUCT REN.EW:JP. BRACKET DETAIL SOUIII n"",.. BUlLDlNC coo, AC..'C1'-~,t.N~NP. tt1-orol.o 5CAL~, 1 ~ ., -0 ~rr~J?~ 1m. ~{~/_2~ NOOlJCT COOlROl DIVOI"" ~. , . IIUILDIJIG COOE COMPlIANCE OFFIC[ PJto L\f~,'_~"~;::;--::-:' ACCfrTNtC(HO.C/t,. 1220 01 BUW)L"IO C\;J, ,:" g u ~J e tle i ;s. ;~" ~I 1:1: ~ ~: a~ii i ~I ~~i~ i i51 :Jll~ i ~I i z > >< ~ a: .II.!! g "':~b .. I;j~~ ~ .aO~Ci -J O.lt; ~ u:ii uz E= 111 J>->- H ~ .11" ~iH ~ I.... 96-399 ..D BUILDING CODE COMPLIANCE OFFICE (DCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUN'IY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) CECO Door Products 9159 Telecom Drive Milan, TN 38358 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami-Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AID). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Imperial Flush Outswing Commercial Steel Door APPROVAL DOCUMENT: Drawing No "RD0849", titled "Series 8070 Elevation Drawing Flush & Glazed Imperial Doors", sheets 1 through 16 of 16 prepared by Tilteco Inc., dated 10/06/03, signed and sealed by Walter A. Tillit Jr., P. E., bearing the Miami-Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence page E-I, as well as approval document mentioned above. The submitted documentation was reviewed by Herminio F. Gonzalez, P.E. ~.~\~\ u ~ ~\c\ NOA No 04-0611.04 Expiration Date: August OS, 2009 Approval Date: August OS, 2004 'Page 1 CECO Door Products NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's parts and sections drawings. 2. Drawing No. "RD0849", titled "Series 8070 Elevation Drawing Flush & Glazed Imperial Doors", sheets 1 through 16 of 16 prepared by Tilteco Inc., dated 10/06/03, signed and sealed by Walter A. Tillit Jr., P. E. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, T AS 202~94 3) Large Missile Impact Test per FBC, TAS 201-94 4) Cyclic Wind Pressure Loading per FBC, TAS 203-94 5) Forced Entry Test, per FBC 2411.3.2.1 (b) and T AS 202-94 along with marked-up drawings and installation diagram of outswing steel door, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0345-0203-04 (specimen # 1, 2, 3, & 5), dated 02/11-21/04, signed and sealed by Vinu J. Abraham, P.E. C. CALCULATIONS: 1. Anchor Calculations, ASTM-E1300, and structural analysis, prepared by Tilteco Inc., dated 05/10/04, signed and sealed by Walter Tillit Jr., P. E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MA TERIAL CERTIFICATIONS 1. Notice of Acceptance No. 03-0916.02, issued to Nebula Glass International, Inc. for "Glasslam Safety Plus Laminated Glass", approved on 1 0/23/04 and expiring on 09/09/08. F. STATEMENTS 1. Statement letter of conformance and no financial interest, dated May 12,2004, issued by Tilteco Inc., signed and sealed by Walter A. Tillit, P.E. G. OTHER 1. Letter from consultant stating that the product is in compliance with the Florida Building Code (FBC). U1vWJ~ ~ () · Herminio F. Gonzalez, P.E. r v 1-' Director, Product Control Division NOA No 04-0611.04 Expiration Date: August 05, 2009 Approval Date: August 05, 2004 E-} CQulk FraIM p..imetlr L .) 33 . -.f" 1/2 .. =Jw" --1 J/8 Undercut @or<!)or ,,,I i .f" 1/2 .. ~J' WO, --J I 40 L 3/8 Undlrcut IILIECO,.... MIAMI-DADE COUNTY J WALTER A. T1LLIT Jr., P. E. P.E. SEAL/SIGNATURE/DATE _~ ~M1 ~,[=WllIl =~ _, ;'&:1-1..,., ..I.tNI D-ODllI71. *,,-TDIIA. llurr.....1". E. Fl.JlIIlDI. U.. "'87 L ./J -33f.3 1/2 Wo, ~IJ L- J/a Undercut ~ ~o. eo:: ~se- ~~ ~::~mer:: ::-2:;or ~~ :- ~= ~=lngand~d. IhowII all 1ft Prvdact ~al Oocumwrt CPAD.) Door IN)' be IrMtWW at. ~h lhiladty ~ Z_. 0MItn wind loade .,aM be 'et.mlHd u per MCItfon , I' It t1f the abOYl mln1fOflM OOIIe. III ont.. 'ID -try ttlot CIIIChon an VIII PAD.. al tMted. .e~ lIot G'l'~d. a "",. r__ In allGWCIbll ... lor wllld load' "I" l-.cIllI tMlr I"al)'ele. TNI Doar'I oa.qucy for I~ oncl qocIIc ,..... h_ bHn YlrtllMI In ac:conIallotl wIttt -uon 110'.1.4 fIf thl 0"- m~"" 11II4I 01 j:Mr TA$-201, TAS-202. TAS-2OJ. _ pel'" HTl lab ,.,ort f034S-02~04 and _ per IllbmItteit ftruetlral caleulctlclr-. perfGmllCI GI per MCtIon '111 of tIw F'lorfdGBYtIdI"..eo.. 2. Dwlgll Pr.eur.: +70 FMf. -70 pet J. Wlfllmum Fra_ C.,th: 5 3/4- 4. s.. Shell 7. Il. . III: 14 far Component Hamlnclatu,. 5. S.. 5tt.t 5 ,.. Anchor OWlI and ~all .. All 0I",,",1on. are III Inoh.. 7. ~. Daar IXlES NOT ,,*,"lre -Hurrlc;Cl", Proteatran Sywt.m a. ThI1 Door !S NOT ~ for WoW IntIItrotlon e~ I. (e) ThlfI PAD. pNJlOrwI by till, IngllI..r I, 81ft.,-!o alld don not prG'ffdl lnfomlotIall for a lite epedf!e praJeet LL .m.r. thl ,nl candltl-. dr./let. from nIl PAD. (b) Cantractar ta be rwponllbll far tM IIIeatIan, l)UIl:haM and w.taIlatfan hclulllnt I.,. 1ll1'-';Y d ItHe procIuct. baIIcl on VIII PAD.. pnNIdld 111/__ dole not dwrotl from the oandltlon. dltolld 011 thll dGC\/mlllt. ConItruct/an _<<r at IIt8 II III. contn::Iclar', ~pOfllIb1\llJ. (e) 1IU PAD. wll be corteIcI,~ ll'lVGld If altered bJ 0", mear& (d) 1hI, PAO. tholl b1ctr the date and orfglnaI .-II and llGncrt.ure at the protwelanal -01"- af ~ tIIet preporId Il 10. Door'. monufacturv label Ihatl be pllICed 0I'l lite ..poeed. 1\1I'1001 d $ or @ ~~~1cI fa' _ryClpl"I"I.labll.naM ~d n folio.,: 1iI15li1 TIlIoom DrM WIlall.T_ Wlomi-DocII Cariy !IrocIuc:t Cantral Apprawd. MATERIAL SPECIFICATIONS: 8070 Flush Series Elevation Drawing & Glazed Imperial Doors II!!! CECO DOOR PRODUCTS _ MIl~n. Tennessee 38358 Finish: Rust Inhibitive Primer, One Coat ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 DRAWING NUMBER: RD0849 Sheet 1 Of 16 Out.wlno Door (Interior View) Rim F'xlt Device 3/8 Undercut MATERIAl.. SPECIFICATIONS: Outswlna Door f1nhlMor View) Rim Exit Device .... ~ Generol Notu' 1. Single 4070 Senes Imperial Outswing Commercial Steel Door w/8enes "SF'" frame jamb and head, ahown on thIs Product Approval Document (PAD.) has be.n verified for compliance in accordance with the 2001 edition of the Florida Building Code. Door may be installed at High VelocIty Hurrleone Zones. De81gn wind loads shall be determined 08 per sectIon 1619 of the above mentioned code. In order to verify that anchors on this PAD., as tested, were not overetr8l!lsed, 0 33X: increase in allowable &trees for wind loads WOI lIlI ussd In their analysis. Thi. Door's adequocy for impact and cyclic r~i.tonce has been verifled In accordonee with section 1806.1.4 of the above mentioned code oa per TAS-20t I TAS-202, TAS-203, os per HTL lab report 10345-0203-04 and as per submitted structural calculationa, performed Cl8 per section. 1611 of the Florida Building Code. 2, Desion Pressure: +70 pst, -70 psf 3. Minimum Frame Depth: 5 3/4- .... See Sheet 7, a, 9 a: 1+ for Component Nomenclature 5. See Sheet SA for Anchor Detail and Lacation 6. All Dimenaiona are in rnchea 7. This Door DOES NOT require Hurricane Protection System 8. This Door IS NOT Approved for Water InflltnJtlon 9. (0) Thia PAD. prepared by this engineer ia generic and doea not provide information for a alte apecific project; i.e. where the site condltiona deviate from the PAD. (b) Contractor to be reaponalble for the .election, purchase and inltallatron includIng IIf. aofety of thi, product, ba.ed on this P.A.D.. provided he/she doee not deviate from the conditione detailed on thl. documenl Construction safety at aite is the contractor's responsibility, (c) Thia PAD. will be conaidered Invalid if altered by ony means. (d) Thi. P.A.D. sholl beerr the date and original 'eat and signature of the prafeuional engineer of record that prepared it. 10. Door'8 manufacturer label sholl be placed on the e)Cpoaed aurloce af $ or ~ One label sholl be placed for every opening. Lobel ahall read 08 follows: CECIl IXIlR PRIlIIl.CTS 9159 Telecom Drive Ullan, Tenne.aIM Ulaml-Dade County Product Control ApprCNed. ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 ~_~ / \ Finish: Rust Inhibitive ~':> IILIECO INC. Primer, One Coot JUN 0 3 2004 .:.~ ~N. ~ -:""... =~ WALTER A. TILLrT Jr., P. E. -,w:.":::':7,,'=HU' P.E. SEAL/S1GNATURE/DATE: ...~ ~ -:":7 E. 4070 Series Elevation Drawing Flushed & Glazed Imperial Doors DRAWING NUMBER: RD0849 Sheet 2 Of 16 M:AMI-DAOE COUNlY == CECO DOOR PRODUCTS - Milan, Tennessee 38358 See Sheet 6 F.or Threshold Details 1/4" Shim Max. Typ. Existing Structure 1/4" Shim Max, Typ. Exist;ng Structure Caulk Perimeter, Typ. (Exterior & Interior) lrt Head l.Iust bII FTI~ wI c;:~r::'..ONLY . Structural m..-nblr ~ / nem. wlo ancnonl. ( -..-, jam":' o~ ~~-,::. ~_J.coil: E-E C1nm~~:ld"lgnod to carry OOl'T'~l'Iclln9.t ctural member at head eel by IIuflding OffIcfal ~OI~/~ c::; lm~O"d and mud be rwf.. 8 4 Sheet 7. 8 &: 9 for ~~pon.nt Nomenclature 8 See For Slab Req'd. See Sheet 5 For Soacing Bit~ ~ t Slab Req'd. .. ""'--- Con ere e B-B Typ. MATERIAL SPECIFICATIONS: ALT~U~ Mrf1!Pr4. P. Ec ~E. SEAL/SIGNAnJRE/DATo JlLIE CO,... TUT"" .. INGlMnfllM' =~ - '.~""~.:1IIII-'.' --~~~1:'E. Sections For 8070 & Vertical Cross . I Doors 4070 Series Impena - CECO DOOR PRODUCTS II!! Milani Tennessee 38358 ISSUE DRAWN BY: REVISIONS DATE: 10 6 03 MWolI DADE COUNTY DRAWING NUMBER: RD0849 Sheet 3 Of 16 e Section C-C ------------~~...._'" --- I' ~) \ I 1'-- , "-_ --i 1.050 I-- // ...............--------...--",;; ~ MIAMI-DADE COUNTY JUN '?OIU WALTER A. TILLrT Jr.. P. E. P.E. SEAL/SIGNATURE/CATE /IILIECO,..\ ~~'" -.,04=""_ =-:r. _ t Y,-lLl. .. '-':"_1., D-OlIOI71. 'MLTDt 411WT J'~ P. t. I'lOMllll We. ....1.7 Typ. 8 Section E-E * Jamb @ may also be attached by pouring concrete into it os per section A-A, on sheet 5. MATERLO.l SPECI~CATIONS, 1/4" Shim Mox, Typ. Section F -F .~ Horizontal Cross Sections Far 8070 & 4070 Series Imperial Doors ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 _ CECO DOOR PRODUCTS - Milani Tennessee 38358 DRAWING NUlIABER: RD0849 Sheet 4 Of 16 4 ~.. t t t t t U 10' ~3.378 INTERIOR f>nAMI: ..w.uI ~MMI!"'" W.IlI () P1Y.IIlr J~ .~;" MIIr.W'rW' H.&I.I . stl'\lcturul memb.... t1(j) at Head t.lu.t be Filled wI concrtlta ONLY wh." jamn ore all n1ed wI concm. ./0 anel'lorw. (F'or ca.. correepondlng to Iectlon. A-A . E-E) In thlti eGU, atruc:tuI'Q1 mlmber at hecd mult b. dalgned to corry 20lb/ft, load ImpoMd and muet b. revlaw'" by Building Officicl 1f~' Shlmif- 10Q- ttlox. Rou;h Ol:la"ln\l PIIAIllI:"-.&T~~M eftMr.B1T . nelr WJ.U.. a-o . 7-11 ~ lIB 3/S- x 5- r.H. LOK/BOLT Anchor W/ 1 1/2- Min. Embedment and 3- Min. Edl;e Dfetance, Exiaiing Opening Arlenor INTERIOR INTERIOR IIIIOIIIILl::[ @ FUMr ~ AT I"II!nWfII ~rn... (2)2x6 min. Wood Stud. Raquired EXTERIOR INTERIOR ol.tlng Op.nl~ Anchor ~ ~erv:: ::.. !IIIlne o a_ ~T-=:- WALL EXTERIOR ~0 ....TERIAl SPECIFlCATIONS: 8~:Jt"-':"=5n Frome Anchor Installation Details For 8070 Series Imperial Door ISSUE REVISIONS DRAWN BY: JE: 10-6-03 MIAMHlADE COUNTY WALTER A. TlLUT Jr.. P. E. P.E. SEAL/SIGNATURE/DATE ~~=-"". ~1!~I"'" :~ _, Wii-,.. ,. ,-",-1U' ~71' ....'TtR A. TlWT ~r.. p, Eo ~Uc. 44117 IILIECO IlIe. ._ CECO DOOR PRODUCTS - Milan, T..nn..ss.... 38358 DRAWING NUMBER: RD0849 Sheet 5 Of 1 6 SI. ShMtl 7, a . II 10r Componanta Nom.clot",,.. 52- Mal. Ro~gh Opening :f.~. Shlm,f- I J J 8- F'DMr .I..~ ..aT ..1M'Ito ~ 08 ~.IfteItw..a.t.1 .."-tJ- . r-w- ~ 'aX :ve" X S" F.H. LOK/Bcx..r Anchor WI 1 1/2- Min. Embedment and 3- Min. Ed~e D1stanc:e. ExIsting OolInlng Anchor INTERIOR @ ...- tif!rI=I.........1I'lI' W..IJl.. (2)2x6 min. Wood Stud. R~ur~ 33l!1- D AHCH~R SPACING J J l!I- ~.I.IIl5oNIII!I.Twtalsn..m!!II ~'-W- . r-tt- ~ -.n EXTElOOR INTERIOR ~.&~mll~ MATERIAL SPECIFICATIONS: MIAMI-DADE COUNTY WAL~A~ *JI!Otr.. P. E. P.E. SEAL/SIGNATURE/DATE / IILIECO '''c. \ ~~~ ~,IMGl.ulHG CCItIl":' -, y,.,..~ I;III.=- . D-~' 'IN,;IO....lLUT;..P.E. 1'I.CfIDlILk. 441~ ~ .Ii tli ~ 0,.,...1 .......~ _1e'Ur EXTERIOR @ -~'El'lI4t~ ~ Frome Anchor Installation Detoil! For 4070 Series Imperial Door s. stIMb 7, l!I .tr: II for Componenb Nomedatul'll ISSUE RE'>1SIONS DRAWN BY: CATE: 10-6-03 _ CECO DOOR PRODUCTS - Milo.n Tennessee 38358 ORAWING NUh,tBER: RD0849 Sheet l5A Of 16 Existing Structure Shim Max, Typ. 8 (2) 3/8"-16 x 3/4" Socket Head Cap SCiews (2) 3/8"-16 Drop-In Anchor w/ 1 1/2" Min. Embedment. Concrete Slab Req'd. Typ. See Sheet 5 For Spacing Sectioll 0-0 · Structurel member @ at Head Must be Filled wi concrete ONLY when jambs ore 011 filled wi concrete w/o anchors. (For case corresponding to sections A-A & E-E on sheet 5) In this cose, structural member at head must be designed to corry 20Ib/ft. loed imposed and must be reviewed by Building Official ~~;.rlOCking m>>"'.' fold Over Tab Interlocking O\l8r Tob Frame Comer Detail l!i~ IILIEC 0 INC. MATERIAL SPECIFICATiONS: ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 ~~ MlAt.AI-DADE COUNTY WALTER A. TILLIT Jr., P. E. P.E. SEAL/SIGNATURE/DATE TIU.lT TISTINlI oil DlGllMDIING ~ANY -~~~li.~,""~.- EI-<IOW>" 1fIlM.1'DIo.'I1..lJfJr..,",[. F\DllI>>.Uo. 441117 Cross Section View Of Mullion Attachment And Frame Comer Condition For B070 Imperial Door -= CEeO DOOR PRODUCTS -= MllCln T..nn..ss.... 38358 DRAWING NUMBER: RD0849 Sheet 8 Of 16 r s.m KATt'UAL SPEClnCATIDNS, 16 G~ (,053) ~20.000~ L636 @ CLOSER REINFORCEMENT ~TERIAL SPE:CIF1CATIl:Jt$l 14 CiA C,067) 1--.rt7 110I. l.1,. I PART NO, DIM 'A' rn STAMP 6100645 ,094 H 6100646 ,060 646 6100662 ,115 NONE @ AT FRAME JAIlAB @ AT DOOR STILE 4 1 /2 DOOR/FRAl.IE HEAVY HINGE REINFORCEIlAENT ~TDUAL $P[CrrICATIt:NS, 7 GIll. <.17',(+.003,-,00:", .~~ ~ ~ lHm~gLO' NATI A 8135N ~o~m r-C.306 O.O~l .a'1 ~ .f5e @ PEIlAKO WEATHERSTRIP ffiQFILE No 303 AS HI! TERlIi. SPECJf1tfl TIONS. NI1..l.. nNISk ALlM. AE1"~NER (6063-111 ALLOY) 'tIISD...lCCNE: SEAL MATERIAL SPECIFICATIONS, ALUMINUM 6063 ~ @ MULLION FITTING STEEL AS'1'\l Cl010 I W I ~~g. IS~O~~~r4ri'2 o fD'1 Lrm~ jrl....~ ~~~ I tW'~ ~ MTER~2 ~C~CAT1DNSI r-2~16---j I r-2JJt6 ---1 I @VISION LIGHT KIT PERIIlAETER CHANNEL N1tJ i i [----r SEE: sHErrs 'i .. 16 (BILL OF : : 1750 :i"~~~.;~ WT~I~'i:i:~TS ...-_...... IS"'U!O :,1, -I': f"2>01 COMPONENTS ~.,~ @"U~;~'" STEEl A1SI !Ilea OR 4140 Yal. Securft;v Inc.. Dwd 80-2000-1114 '-nt:]D a TOP OF DOOR ~ BOTTOM OF DOOR ~TERIAL SPECrICATlDNSI II GI. (,093" 1'IIn) CS Type . CAS: I 3OAn_ I L L~~~~~~-::::.__Hnm___________mn:" J=L """ J 12 G.. CR' Q3 HORIZONTAL STIFFENER DO 01 0'"rr]--i;J"1 0,'88 '-2' r :5.250 J ~'" ~12,OOD~ I-L6J6......l aM @ DOOR LOCK REINFORCEMENT ~ATtRIAI... SPECInCATIDNS, 1e CiA em::!) LC::lr~ D.~ 631 HAGER 891S wE..:tl!gg~-fBIP PROFILE ALIJoIIHUM 6G63 T::I ~TERIAl SPECIFICATIONS; ~ / IILIECO,.c,\ >> 3 ~ ~.. ~7,=U:"HG =:'" WALTE~~T1lLli99.~ P. E. _'~~;;".~.'1Il P.E. SEAl/SIGNATURE/DATE 'lIML& l:;" J..1:7 t. ~IAMI-OAOE COUN1Y l-.o~ 000 ~J1' @ DOOR EDGE REINFORCEIlAENT MATERIAL SPECIf'IC.tlTItJrtS. 12 Cia. ern: S--~:::J (TtPt]"' ;:LI~ J""s ----I 3.llQQ OJ07 TIP o YALE HARDWARE MULLION Ml00 en KRIIA ASnt A-'.'!illl, GRAil: I ~:'~-~:l 8070, 4070 &: 3070 Series Imperiol Doors _ CECO DOOR PRODUCTS .. Mllo.n, Tennessee 38358 OJ" (Jg BRACKET MOUNTING O'TOP OF MULLION FITTING STEL ASTN Cl010 Yale SltCloIr!ty Inc. Owg I 50-7000-1418 'SSUE RE:>'ISIONS DRAW~ BY: DATE: 10-6-03 DRAWING NUMBER: RD0849 Sheet 7 Of 16 r-2~"'--tl -j r-'''' ~ In ~~ m. I L343 ILO ".1--- @ MULLION SPACER BLOCK MATERIAL. SPE:C1F1CATIQIIS' C.. IL~'ml "'0001 TI =-====-==::::- ::---:. ,:'..'f.,-"I- @ FRAME HEAD BRACKET REINFORCEMENT (AT MULLION) r-EEt}' " " I II II " II " " L6llS -11'---1_-_- L" " " II R II II R II f---- - ~ l S.ctlon 88 B- r-'~__ E'rr ~.,~-s ~.'''' .D+D.-:foo ___ __ -1 .- - ---- .1.000 @ CYLINDRICAL LOCK REINFORCEMENT WlTtRtAL SPECIF'ICATItNSI 12 CiA (.1l"J3) CS TYPE B ~'"'' II II jI , II.. II II m II " , ". ~TYP @ CYLINDRICAL LOCK GUARD ~ NATtIUM. SPEC1f'1CATIDNS< 18 CiA. CR c.aq) I Olin"'" I Olin"&" I 3.000 .187 ~~- 1--200---1 ~5J2:i~ Q.87~ c>.",F~ ,elll'.12' /~1. L'dJ S.ctlon -A-A- D F:"\Il:'2~ ~ (2 plo,cn) 1I.lIl. @ FRAME STRIKE REINFORCEMENT (LSRA) HA TEltIAL $P[Cl"ICA TIONS, 12 GA. .093 NlN EXISTING OPENING ANCHORS 1"Io.".!"tG1 SpI'c1Flco;tlo"1S1 18 go. ga.lv, ~ = LA~H REIN C T " " RING NATEI!,ilL SPtCIf"ICATIO'6I .015 1l,9~ COIC CWOV, CR$ ~ SEE: SHErrS , L 16 <lULL or MATERIALS) F'CR CCflPONENTS NOT ~C'WN IN THIS SHEET COMPONENTS MATERiAl SPECIFICATIONS: MIAMI-DADE COUNTY ~~ / hLIECOII'c.\ JON 0 a 2004 ~ ~ ~ 1:""'"_ ==- WALTER A. TlWi Jr" P. E. _''''~~.''''_1'' P.E. SEAL/SIGNATURE/DATE M.~ ~ ~l:;[. 8070, 4070 c!c .3070 Series Imperial Doors ISSUE REVISIONS DRAWN BY: DA : 10-6-03 == CECO DOOR PRODUCTS - MIle.n Tennessee 38358 DRAWING NUMBER: RD0849 Sheet 8 Of 16 ]rTEIA Q1Y DESCRIPTION MATERIAL SIZE I (J) 2 Per ~::.nr::I'ISk.rJ ~~;3u~. AmI A65J Qal\fo""'eol,d CQ at Frueh 6: Commercial Q\.IolR)' GahoonrlH*I SleeI (Minimum 'I'IIiId sv.n,th of JI,OOCl pII) lei Gouge (0.053- Nln. ThIck) (2) . H .r 981111li1 Hr"e. Eo. Attached IlIlth EI tit 12 24 II 1 . F.H. 11I.5. 5tH, 4-1 2- II 4-112- )l 0.180. Thick ~ 2 o.tlll H10 SIrieI ExIt DIYice s.s. J04. Of' 318 Pallid.,. W.wl fw Latc:tl Bat cry .. 47 1mI). 13 Ga. CRS SUrface Strfk, Attachecl to Door with (2) 1/"--20 iIl.S. (!) 2 o.tt. H40 541". Exit o...lce WI Hard,... f!I Rb 10-10 fIN' Hou.lnlJ (Fy .. M 1eI1). S.s. J02 ~ent Surface Strike Attacl'led to Door IrItt1 (2) 1/4--20 "'S. Colt for StrIke (I')' .. ;)Cl 118I) and So!. 17-4 Ptt iIIn Latch ItoIt fF'1 .. 145 <!l 2 0etI. HV40 Seri_ Exit [)eyrel 1*). AI th-. componentli ar. Ylllel fvr 0.-. H10, H-44I ill; HV4Q Surface StrIk. At1ached to Door ",Ith (2) 1/4--20 ...S. ~ - ~i:.a~;m= ~IU~.ll~H=~ Q;: ;{T~ Y~~,~~II;.~;;:J W1aml-CocM County Impact R../atant laminated Glo.. 3J 1/8- . 31 1/'- nt.tayw . pr NCll\ , OJ-022a.1Q wI Edge PET FIlm PM He>>. , 03-0818.02 crI , Yol, Hardwar. !>Aullian, hil100 (F) KRIiI ASTM A-500 GRADE: B.. WI f'y(mrn) -o4Oksl At: Fu(JTdn)_~ (1.5- II J,O. II 0.187") R.d OIddl Palnbtd Or Equal. 2 Ib/tt' Olnsit)', wI the fotlowlng f1n Burning charactorfetlCII ~ Rell'd Umhen. Cor. JloIym.-lc: 1.101 Foam Sy.t." I, a two JlOrt liquid, ..If odh..l~ to T... _ _ _, (E1ari~ore P1B29JR Ruin Compcn"ntjElalrtoporft P1001U Ilocyanate) okln when cUAd ,f,fJV E .... F1ctme IpNad 20.... (FSI) U.L IUI8I2/DlnlcJH3J ..... E .. ......- 331.1 (SOl) U.L Retl2/01nIc3H:5J ASI'M D-112111 ... ...- .....- 7el.F S.W.R.L 01.100u.01.1127 Spontaneoul tnltSon ...., S.W.R.I. 01.1OCUOU17 $ 2 =- SIl;~' ~':~~~~ =" ~o~=~~;{ ~80 Coatln~ ~:.n~~~I~'"G~~ICI"d steel fUJnllTllolm YIeld Sl:renath of 31.500 ....Tl 2 ~Va- Fa", !5-3j4- Depth IMn. @ 2 StIff.. "sr, Fram. Head, Double RablMt Proflll w/ A-80 CoatIng i e Ga. (O.0e3 "In.) stMI 2 5/a- FOCI, 5-3/4-- Dlpth Min. Fael Sheet CanformIng to AS'TU ASS3 GdYannlaled CO Commerdal Quollty (;olvanl'llClled 51.. (Wlnirnllm YIlIId str.ngth of 31,500 F*) 0 RII:I'd G...ral Elec:tl'le CcIulk (GE All P'l.Irpoee Silicone) For W~ Screw.. From. Sllcon. Silicone Rubber General Houuhold Pwimeter, From. STH Co",.... and Un_ Sill l} 2 Formld stl.l Chonn.l w/ A.-eo Coating Conformln'll to ~ ~".5J GolYClnnealed Commercial Qullllty ClIlvonnlClfed st_ (lr,linlmum VWd 5t.rw1vth of 31.500 pill) 3/+" II 1.MI"" II J/4" 11 12 ~ (0.093 ~n.) Cent. CQ on Th Top ot Both DoorI. Spat Welded Bot/'I Ski", . 3 1/2" O.C. @ 2 ~~~tio~:T':~~"'ooor:'n.fo~:IIASTM ~1008 end A5'I'lr,l ASlI at Each CIa'; st.. by C.eo Door Producta. Ole , 4-841 5 3/s" High . 1.SJe" . 14- GA (O.OSl Win,) Channel 43 2 HofIzorrtCIl Stlfftl'lW Confarmlnt to AS1lI A10Cle end ASTU AS68 w.ided to roc. Sheet Commercial Duality Cold Ra~tcl StHl (Minimum Y'M1ld 5trenljlth of 31,500 p.i) 5/16" . 2 1/2" . 15/16" . 12 Got.. (O.0I3 Win.) Channel @ 2 ~<<;': =. C;~n~~ A~ =ng ~O~1o;!"~~t to ASN A~ on The Top Cammerdal Quality GlIM1nnollled St.1 (W1nll1'1.lm Y1e1cl 5trwIgtl'l of 31,500 ..l 3/4- II 1.656" lC 3/4~ lC 12 ~ (0.083 Win.) Cont. 0 2 Notional Guard Thr..hold 1813eN on a Back Bed of Caulk 13 Extrvded Aluminum (1S05J-~ Alloy). with 1/4-.3/8- Sllcone WlCltheretrlp 48- Lanljl Eo. (1/2" HJgh . :5 3/4" WId. . 0.013"/0.115" thick) l} , I ~~n~~~2~1i:, X!WoI(~o~~tt5/8' l>CkIt Confomllng to ASJ\I AS53 CclrnrMrT;1a1 Quelll:y GlIl'1annlo!.d still (Wlnlmum YIeld streng1tl of 31.5DO 1Mi> 18 CcI. (.042 Min.) . HIngt; lWrlfondng PI" Spot ""'did to rrome Jamb at Each Hlngo Location stHl IN Ceco Door Product., Ole 1 4-7J2 1 1/+" . Q- II 7 ~ . HInge ReInforcIng ?lat.. Spot Wolded to Door EOgi at Eacll Hinge Locatlon St..1 "" Ceca Door Products. 01. .. 4-732 1 1/4" x III" x 7 GA. . Door l.ack Relntorclm4lnt Conf'onnin'll to ASTN A'OO8 o~ ASTW ASea Still by CKO Coot' Products. Ole 1 4-041 5 1/4" II 1.531" x 12" . 12 Ca. (0.013" tolln.) 2 Ptimko WNtherMrtp, Profile Number 303 AS 1,411I Flnieh Aluminum Rretainer (6063- TS Alloy) with Silicone s.G1 1/a".1/4-~II'Il.) + 1/4"x5/W (Slicone) AttacMd 0/ Io.S/a- s.c.S. . ~ O.c. 1 Sot Hoger W~P. P","!. NlJll'lber IllS. All Around Frome Jamb .. He. tolin FlnTlh AlumInum ""-alner (e08J-~ Allay) with S11leon. Seal 3/4"1l1/4~um.) + 1/4".'/4" (SliCOM) IttacIltd -/16x3/4- 5.0,s, . 9- O.C. 0 2 g: ~:: :!in~~=t Confonnin9 to ~ A100s ond ASI'W AS88. W.lded t Camrr.-clol QuotIty Cold Roiled stili (Mlnlrrun YIeld Strenglh of Jl,~ pII) 1 1/M" . 1 !iI/.32" )I 1 1/54-" . 12 Co (0.093 Min.) @ .. ..... !~,!'!P!'~.. ~'1_~~met-: Ch~nne.. Co'l",prml"i_~_ ASTIll Al008 and AS'TlA M6S, Comm.rdal 0u0I1ty Cold Rolled steel (1fti1Tlum YIekl Stnngth of 31.SOO pel) I" . 1.666- II ,. Jl 12 (;0. (o.08J Min.) ~~ , "ulnon Spacer Bloclk at Top Yale Sec:u1ty, Inc. Orawn Steel Aluminum PGintlcl 0."2~- x 1.250" x 2.375- @ 1 F~Jr1,.....~..!I,tadcet RelnflrCllmlnt at Mullion COl1formln'll to ASi"N A1C1Oe Commercial Quality Cold Rolled StNI (M"lfIimum Yield strength of 31,500 pei) 1.1525- . 3.4M- . 14" . 12 Gel. (0.0113 "In.) ~eq'd' Exletlno Opening Anchor w/ 3/11-' . 5" F.H. Lok Bolt, b)' Pow.r Faate"el'l !ne. Qalvanizlld steel by Ceca Door Product:e, Ole , 4-&22 18 gage thIck Rell'd Ellletlno OpanlnO Anchor with 3/8'" lC 8- Waod la'll Setew GoIv1:lnlzecl St..1 0)' Ceca Ooar Pnxlucts. 011 , 4-1522 18 Ollge Thldl: . Ro~'d Tapeon.. by Elell Toxtran or rrw Bulldell . 10. a.c. and J 3/8" from End. st... 3/18"' II 1 3/4" F.H. , Top Mullion Fitting 8820 StnI 011 pIN' Yell. Security, Inc. Slri.. 7000 DWG# 1SO-7ooo-1412 3.J8".3.12.Jl2.2~" WI (4) 1/4--20.1 1/4" 1.4.5. , MuWIofI Foot Brack.' srtEI. NSI a1~0 OR 4140 AS PER YALE SECURITY INC. 0WGf 15O-2000-t1fl 3.!S" . 1 17/32". 1.15- . 0.205- ThIel(. ..... OIozl"'II Stop at I/Ieio" LIgtrt: 5.,lont Daw ComIn; 980 StI1Je1ural SIIlc:ane , helm t.Iountll'l\i lit Top of WWI:1l1'I Flttln9 A.ST\t Cl010 al per YIII. Security, Inc. S.r1.. 7000 ewe, GO-70c0-l.111 1/2~ . 3.38" x 2.25- . 0.188" ThIck. BILL OF MATERIALS MIAMI-DADE COUNTY l.tATER~ SPECIfICATIONS, o....~!.. hLIECO,..\ ~...-~-~.i JUN 0 200... llUJT TUnN. . OtGINIEPlI... eowNft' . WALTER A. TlLLIT 'Jr., P. E. -"...::';~~~I''''~'''' P.E. SEAL/SIGNATURE/DATE ~ ll..~ ~t:,E. 8070 Bill & 4070 Series Of Materials ISSUE REVISIONS o WN DATE' 10-6-03 . CECO DOOR PRODUCTS - MllQn Tennessee 38358 DRAWING NUMBER: RD0849 Sheet 9 Of 16 86" Max I 11 Caulk Under Threshold Out.winD Door (Exterior VIew) ~~ MIAMI-DADE COUNTY WALTE1IUll MrfO.J14. P. E. P.E. SEAL/SIGNATURE/DATE 83 1/2" Door 8S" Max Max I ! / IILIECO ,.... \ TlUJT BSTING & II:NIilIfllDIIHO CO....ANY - Il&"=; "'1~~~~ ,..,,~ >>,.. "'-"""'" ~~~~~1:7E. 11 Coulk Un er Threshold Ouhwina Door (Exterior VIew) ~ MATERIAL SPECIFICAT10NS: -- 1. Single 3070 Serle. Im~riQI Out.wing Commercial steel Door w/.,rI.. "SF"' frome Jamb and n,ad, .hawn on thr. Product Approval Document (PAD.) MGI been vtlrlfied for compliance in Q~ordor'IC' with tn. 2001 edition of the Florida Building Cod., Door may be installed at Hill" Velocity Hurricane Zonl.. o..lgn wind loode aholl be determined o. per aeet/on 1619 of the above mentioned cod.. In order to verffy that oncMors on thl, PAD.. 01 to.ted. Win not overltreSHd, 0 331 inctllC.. In aHawobl. atrHII for wind load, WOI !!lI uHd In their 0"01)'1I11. Thi, Door', odllquoC)' for lmpoct and cyclic reli.toncl hClI been verified In occordanc. rik HCtIon 1606.1.4 of the abov. m.nUoned cod. oe p.r TAS-20l. TAS-202. TAS-20J. QII per KTL lab report 10345-0203-04 and aa per aubmitt.d .tructurol calculatlona. p.rformed aa pllf' aection 1151 1 of the F1or!da Building Code. 2. Design Prsslure: +70 psf, -70 pat J. MinImum Fn::Im. C.pth: 5 3/4- 4. See Sh_t 7. 6 &: 16 for Compon.nt NomenclatUAI 5. 5.. Shlet , 3 for Anchor Detail and location a. All Dim.naio... are In inch'lI 7. Thitl Door DOES NOT require Hurrit;:ane Protection System 8. Thl. Door IS NOT Approved for Water Inflltratlon g. (a) Thia PAD. prllpoAld by thl. IlI'lgin..r I. generic and does not provide Information for Q alte lIpeciflc project; I.e. who,.. the .ite conditions deviate from the PAD. (b) Contractor to b, ,"pan.lble for tn, .,I,ctlon, pun;:hale and Installation Including Ilf, aaf,ty of thl, product, baud on this PA.D.. pr~1ded he/.he doee not deviate from the conditions detailed on this document. Construction aofety ct IIlte Is the contractor's reaponllblirty. (c) This PAD. will be considered invalid if olterecl by any means. (d) Thi. PAD. .hall bear the dote and arfginol seel and signature of the prof_ionol '"!illnllr of record that preparlld it. ~~rl:.or~~ ,:i)o~rU~l.l,..r 10b.1 shall be ploclld on the expolled One label shall be placed for every opening. Lobet IIholl reod all foUowa: CEaI IIIDI PlIIlIIUCTS 9159 relecom Driv. Milan. T.nn..... ~lnm._llntill CnlJ"tv PmdlJ~t Cllntrnl AI"lDrnv_d ISSUE REViSIONS DRAWN BY: DATE: 10-6-03 Finish: Rust Inhibitive Primer, One Coot 3070 Series Elevation Drawing Flush &: Embossed Imperial Doors DRAWING NUt.4BER: RD0849 Sheet 10 Of 16 .. CECO DOOR PRODUCTS - Mllcln, Tennessee 38358 Existing Sj:ructure Caulk Perimeter. Typ. (Exterior & Interior) Concrete Slab Req'd. Typ. (See Sheet 13 for Spacings) Section A-A ~IAMI-DADE COU'fTY JUN 0 WALTER A. TIu.rr Jr.. P. E. P.E. SEAl/SIGNATURE/DATE / IILIECO,... \ .:.wr ~... ~ ~aNN. ==- ~'~lL:.,,",~_,Ul _no l'W.1tJI 4 nun Jr., II, E ~u..44'17 1 3/4" thick Embossed Skins Optional MATERIAL SPEC\F1CATlONS: See Sheets 7. 8 & 16 for Components Nomenclature ~ Vertical Cross Section 3070 Imperial Door == CECO DOOR PRODUCTS - Milcln Tennessee 38358 ISSUE RE'IISlONS DRAWN BY, DATE, 10-6-03 DRAWING NUMBER: RD0849 Sheet 11 Of 16 1.750" Section B-B (See Sheet 13 1/4" Shim Max, Typ. ... . ..41 . .~ .... ~. '.:. 4"4' Sheet 13 for Spacings) ------- / / / , , , , \ \ \ \ \ I I I 1 ~6 '. .... .,' ....,' "-"" . ~.:..' .;. .. . ., See Sheets 7, 8 & 16 for Components Nomenclature I I I 1 1 I I I \ \ \ \ \ """ -J,.o5o.L 1 I I I / / / / Embossed Skins Optional . ------- ~ ~ATERIAl SPECIFICATIONS: Horizontal Cross Section 3070 Imperial Door = CECO DOOR PRODUCTS - MILQn Tennessee 38358 ISSUE REVISIONS DRAWN :fE: 10-6-03 MIAMI-DADE CCUNTY IILIECO ,". T1l.UT TDTlMII . DHlIMDRl... CO/rif'AHY _.....:'i...'!\~~'_,'.... -. lMLTP AollJJT Jr., P. L ~Uc. 44107 DRAWING NUMBER: RD0849 Sheet 1 2 Of 16 1/4" Mox 1/4" Mox 86' Rough Opening Poured Concrete or Concrete Block Well W/Greuted Cells Required (2)2X6 min. Weod Studs Required 86' Rough Opening I C .....-J Slob ~~~~~~~~ ANCHORS AT CONCRETE BLOCK WALL 3-0 X 7-0 DOOR SIZE Soo Shoots 7, 8 &< 18 for Componente Nomenclature II 10 C.J- ANCHORS AT WOOD STUDS 3-0 X 7-0 DOOR SIZE Concrete Slob Required ~~ 1/4" Shim Mex ~ 3/8" x S" F.H. Lek/Belt W/1 1/2" Min. Embedment And 3" Min. Edge Distonce ~ .375 Undercut Poured Concrete or Concrete Block Well W/Greuted Cells Requireh ~ ANCHOR >listing Opening Anchor 11 CI~terlV ~lLA=A BOLT .AT t.iASONRY WALL Existing Opening ~ Mchor ~11 SECTION B-B @ ANCHOR BOLT AT WOOD STUDS 8 !\ x 1 i F.H. apecn Anchor W/1 1/4 min. SECTlO~-C embedment ~ ANCHORS AT tt9 THRESHOLD (NATIONAL GUARD 8135N) MATERIAL SPECIFIC,ATlONS: MIAMI-DADE COUN1Y ~ /IILIECOII'c.\ TlUJT~NGI"EHGIINnIUHClI~Nl'f W,4l.:ral""OrI.t26QI." p, E. -....~....~5~~.'. P.E. SEAL/SIGNATURE/DATE 'IIlL~ ~ ~1:'E. Frome Anchor Instollotion Detoils, 3070 Imperlol Doonl ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 .. CECO DOOR PRODUCTS - Mil'>n Tennessee 38358 DRAWING NUl.l8ER: RD0849 Sheet 13 Of 16 VISION LIGHT CORNER WELD DETAIL 1/4"xO.045" thick 3M Series 4085 Double Coated Urethane l Foam Tape each side of PET GLAZING DETAIL .475" Overall thO k '/8" / laminated glass IC ness , x1 2" close f' T' composed cell foam tape o. wa lites of .188" thO Pe NOA # tempered I Ick r tho k 9 ass with a 100" 03-0812.07 IC glasslam safet . S interlayer W/1 5" Y plus II 010" . edge INTERIOR . thick PET fI . Glasslam NGI,' INC. I m by 1l6x 1 1/4' S,D,S, ~ 9 3/4' O,C, MAX, 37 Dow Corning 995 structural silicone sealant (1/8" thick) 45' Typ 18 GAGE ev 1 VISION 2,000 Typ ISOMETRIC MATERIAL SF'ECIFICATlONS: 8070 & 4070 5e' Vision Light K"trleDs D.oors I etads == ~~~OTe~~OsR PRODUCTS see 38358 ISSUE REVISIONS RAWN BV, DATEo 10-6-03 DRAWING NUMBER: RD0849 Sheet 14 Of 16 MIAMI-DADE COUNlY JUN ~ / hLIECO \ WA TlWT INC. LTER A. TlLLrr Jr P E -.... ~ ~,INGlHIIlIH. CCIlIlI'AHV P.E. SEAL/S1GNATIJR"E/DATE -:w.TfJt~Y/'tIf.,~- ~Uc..J"'1:;'[. ISOMETRIC i E:LEVATION CYLINDRICAL LOCK DETAILS MIAMI-DADE COUNTY WAL,f~tt OTMp~.. P. E. P.E. SEAl/SIGNATURE/DATE Interlocking fold over tab (folded) Interlocking fold over tab o Frome Head 5.754,,-J Corner miter seam fully welded @ frame Jamb FRAME CORNER CONDITION MATERIAL SPECIFICATIONS: / hLIECO",c. \ T1un TDTlNO . IJrlIIMGlllN. COW~ANT ~..~..~,...,:'- EI-OOOlI71. 'MlTtR Ii.. TlLLI1'Jr.. 1". L 1'L.ClltCI.Uc. 441.' I!iu\ Cylindrical Lock Details And Frame Corner Condition For 3070 Imperial Door == CECO DOOR PRODUCTS - Milan Tennessee 38358 DRAWING NUMBER: ISSUE RE>1SIONS DRAWN BY: DATE: 10-6-03 RD0849 Sheet 15 Of 16 BILL OF MATERIALS I fTEt.l Q1Y DESCRIPTION t.lATERIAL SIZE J) 2 Pr ~l}c)...::~etCo~l~t;.rmlnQ to ~ "653 Golvo"nealed CO at Flu.... Imperial Doorll Commenial Quality liolvcnneoled St..1 (I.llnlm\lm YIeld Strength of 3ll,OOO p~) 16 Gauge (.053- l.fIn. thick) ~ J HClQ.r BBf19S1, St... Hinge EClCh Attach.! with EIght "2-24 11 1/2- F'.H. M.S. ..... 4 '/2- x 4 1/2- x 0.1ao- thIck. 2 Ib/tt Deneity, wi the followin; Flrt Buml"1I cnaract.n.uca Urethone ConI T'" - - -, Illi Req'd ASTU E .. Rom. ..- ~;~~~ U.l R5012/0'nkJH3J (E1o.topore P16293R Resin ComponentjElostopore Pl001U IlIocycnate) Polymeric MDI, Foom System '9 a tWQ part liquid. seff ASTU , .. SmoM D.v.IopecI U.L RSet2/D1nkJHJJ adhesIve to skin when cured. AST\l 0-1929 Self I,nllon: F10ah ignition 781'F S.W.R.I. 01.10oas.OU27 Spont,oneolle Ignition 12B"F S.W.R.I. 01.10015.01.127 II> 2 Serle. "SF"', Frome Jamb. Doubl. RI3bbet. PrcfII. wi A-60 Coating. 16 GG. (0.053 hUn.) St..] 2. S/B- Face. 5-3/4- Depth hlln. Foce Shut Conforming 10 ASTW All~ Gatvannealed CQ Camm.rcial Quaiit)' Galvannealed st.., (MInImum ytllld Strwngth of 31,500 pili) @ 1 S.rle. "sf", From. Head, Oau~. Rabbet Prom. w/ A-SO Coating. 1 e Ga. (0.053 Win.) steel 2 S/S- FClC., 5-3/4- Depth Min. Foc. Sh.et Conforming to ASTN A~ Gol'lanneollld CQ CemtrHlrcial QUClllty GClMlnnllot.d St.1 (l,4inimum YIeld strength. of 31,500 pei Gj) Req'd General Electrlo Coulk (GE All Purpon SIlicon.) fot Weatherwtrlp Screw.. Frome Silicone Silicone Rubber General Household Perimet.r, From. SI' Com... ond Under SlII @ 1 ~~:,d T~"~ ~~e~c:c.~s: c;.o;:: =a~~: :: 3~2t-6~. Gal'lann.eled CQ Cemmerciol Quality GalYanneol.d Steel (l,4lnlmum YIeld Strent;1tl'l 01' 31,.500 pei) 3/4- If l.W- x 3/4- . 12 GA. CoM. (0.0113 Win.) Cant. 0 1 ~~-:~III~=~~~'e: ~~~;ndpa~ IoeS8, St..1 by Ceca Door Praduc:ta, Di. , 4-941 5 3/8- HIQ" . 1.&36- x 1. GA. (0.067 hilin.) Channel @ 1 Formed St.l Channel w/ A-6D Coating Conte""Ing to ASn.t Ae!5J GaI'lOnneoled CQ Camm.rdal Quality GOM2nnRIed st..l (Minimum YIeld Strength of 31,500 pel) 3jJ,- x l.65S- x 3/4- x 12 GA. (0.093 Illln.) Cont. on tne TQP of Both DoOl'll, Spat Welded Both S6c1nl 0 3 1/2- O.C. @ , National Guard ThrwMald 18135N on CI Beck Bed at Caulk @ Extruded Aluminum (eoeJ-~ AlICI)'), wlttl 1/4-X3/S- Silicone Weattlentrlp 48- lllng Eo, (1/2- H"91 x 3 3/4- 'Mde If OJlSJ-/0.'1S" thick) @ J HlnQII ReinforcIng Plate, Spot Weld..:! to Frome Jamb at Each Hinge Loeatlan St.el by Ceca Door Pnxtuctl, Die , 4-732 1 1/4- x iii- II 7 G,\. ~ J I-I'nge R.!nforclng Plate, Soot w.lded to Door EGg. at Each Hinge Locotlan 5tH! by Ceca Door Productl, Die , 4-732 1 1/4" x S- If 7 GA. ~ 1 Sot Hoger Weathl!lnrtrlp, Profile Number 8915, All Around From. Jamb + Head hillll F1nleh ~um'num Retall'1l1f' (SOa3-ns ~IO)') with SIlicone Seal 3/4"1l1/4"(AJum.) + 1/4-111/4- (Silicone) Attached wI f6xJ/4- S.O.S, . e- D.C. ~ Req'd ExIsting Opening Anchor w/ 3/S-' . 5- r.H, Laic Bolt, by Power FOMen.,. Inc. GalYon!ud StnJI by Ceco Door Produc:ta, 011I , 4-622 1 II Gage thIck <m Ft.q'd Exlstlnlll Opening Anchor wi 3/8-' I( 6- WO(lI:j Lag Ser.." GclIYCInlud stMI by CeCQ Door PtDducta, Ole I 4-1122 18 Gage Thicle ~ "eq'd Topconl , by Elce Textron or nw !:II.lildu 0 10- o.c. and 3 3/8- from Endl steel 3/1S--'1 3/4- F.H. 13 1 Bat 93K70150-S3-S26 CyI1ndrlC<ll Lock ... per a..t ~. S~eme CWO f G4-QOO-OO21b @ , CylIndrical Lock Quord GoNaniDd Stell la 90ge CR (0.042) If 10.75 Ceil, bij Clce Ollar Pradub, Dill f 4-741 1.805. x 3.280. II '8 Ga. (0.042 Min.) @ , CylIndrical Lock Reinfcwclment steel, by Ceca Deor Produt., Ole I RDOS2S 1 1/4" x 4 1/4- x 12 go. (0.0113 min.) ~ , Door Latch Relnforcem.nt, 5te.1 -C- RIng w/ Goh..anneal ~80 Cootlng, ~:e', (~~~~~ ~~a~I:~d7i,R~mper NY). by Ceco Door Produt., .015" 1Nck If 1.J'3" IIlIIidI DIarrIIt. I O.lI]S- Lang @ 1 Ff'lllnl Strike IWnfan:llTlIIIrI. SpoIwllOld To IAc:k Jamb at Strike lAc:otlon StHI, by Ceco Door Produta, ex. , LKREF'-11. Part No LSRA 1.750- II 7.000- If 12 /l1CI. (0.093 m!I'1.) @ 2 Per ~ac~~etC~lr;.r:.rmlng to ASilol A653 Golvanneoled CQ at Emboned lmperfol OOOnl eommerclCll Quo!lty Gal'lOnl'\lll.d st..1 (!.llnlmum YIeld Strength of 31,500 pal) 111 Gouge (0.053- 11I11'1. ThIele) ~ MATERIAl SPECIFICATIONS: 3070 Bill Of Series Materials ISSUE REVISIONS DRAWN BY: DATE: 10-6-03 MIAMI-DADE COUNlY S) ;-:;~ Ll!,~I.~.~~~.~.~ WALTER A. T1LUT Jr.. P. E, "~"'~~e'''''''' P.E. SEAL/SIGNATURE/DATE 'MI.~ n,.urr "::i.l:=' r. II CECO DOOR PRODUCTS - MllQn, Tennessee 38358 DRAWING NUMBER: RD0849 Sheet 16 Of 16 Karen Miller ' From: Sent: To: Subject: Karen Miller Wednesday, December 19, 2007 1 :59 PM 'Karla Sherrell' RE: NAPA Project-Zephyrhills Karla: Correct...these are the only comments you should receive. If you submit revised drawings there may be a revision fee and additional comments concerning these revisions. A total of three (sets) of any revisions should be submitted. You do not need to send Full sets. Still awaiting on approval from Planning to proceed. Have you Contacted them? (813-780-0006) If your contractor/subcontractors can not come into our office you can have them contact me referring to the NAPA project and I can go over our requirements in getting them into our system and signing on the permit via faxing. Will need a notice of commencement at time of permit pickup. We will be closed for the holiday on the 24th and 25th of December and then on Jan. 1. Have a great Christmas!! Karen Miller City of Zephyrhills - Building Dept 813-780-0020 ext. 3513 813-780-0021 Fax kmiller@ci.zephyrhills.f1.us -----Original Message----- From: Karla Sherrell [mailto:ksherrell@greenbergfarrow.com] Sent: Wednesday, December 19,2007 1 :44 PM To: Karen Miller Subject: RE: Hi Karen! 1 Hope all is gqing ~ell this week! I just wanted to confirm with you that the comments that you sent were the only ones that we will receive, (Le. that all departments have reviewed and made their comments?) Also, we are planning to address these comments and return the revised drawings to you all. Will we need to send full sets of revised drawings or just send to you the revised sheets; and how many sets will you require on the resubmission? Any information that you can provide would be great! Thanks! Karla J. Sherrell Greenberg Farrow 404 601 4000 -----Original Message----- From: Karen Miller [mailto:kmiller@cLzephyrhills.fl.us] Sent: Thursday, December 13, 2007 2:57 PM To: Karla Sherrell Subject: <<IMAGE (2).TIF>> <<IMAGE (5).TIF>> <<IMAGE (6).TIF>> Karla: Attached is the Fee Sheet and comment sheets from both the building dept and the fire marshal. If you have any questions concerning the attached, please give me a call. Some of the outstanding issues are: Contacting the Planning dept (813-780-0006) and resolve the 4 outstanding issues. I am awaiting approval from the Planning dept in order to proceed with permitting. Notice of Commencement (can be supplied at time of permit pickup) Register your contractor and subcontractors. Please 2 note we will need their signatures on the' permit application. Please contact me tor options. Thank you. Karen Miller Building Dept City ot Zephyrhills 5335 8th Street Zephyrhills, FL 33542 813-780-0020 ext. 3513 813-780-0021 tax kmiller@ci.zephyrhills.f1.us 3 Karen Miller . From: Sent: To: Subject: Andrea G. Morrow [amorrow@pascocountyfl.net] Tuesday, December 11,200710:50 AM Karen Miller RE: Address Needed Karen, This address is 6901 Gall Blvd Thanks, my Thanksgiving was DEE-LlCH-US!!! Hope yours was too... Gail Morrow Pasco County Survey/Addressing Dept. 727 -84 7 -8140 Ext. 8370 Fax: 727-815-7000 -----Original Message----- From: Karen Miller [mailto:kmiller@cLzephyrhills.f1.us] Sent: Monday, December 10,2007 11 :12 AM To: Andrea G. Morrow Subject: Address Needed <<IMAGE (4).TIF>> Gail....Good Morning. Haven't spoken to you in a long time. Hope your Thanksgiving was delicious! I need an address for new commercial construction. ParcellD: Type: Bldg Facing: 03-26-21-0010-01600-0021 Commercial - Napa Auto Parts - 1 Story 301/Gall Blvd (Main Entrance faces parking) Their permit application showed an address of 6855 Gall Blvd but that belongs to the business south of this project which is the Golden Corral Rest. Any problems or questions, you know where to find me......Thank you. Karen Miller 1 City of Zephyrhills - Building Dept. 5335 8th Street ' Zephyrhills, FL 33542 2 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t:404 601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DAlLAS NEW JERSEY ST. PETERSBURG Letter of Transmittal December 21 , 2007 To City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 . 813.780.0020 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 From Karla J. Sherrell We are sending you the following enclosures via Air Express - Standard for your use: Building Pennit Review Copies/Sets Date Description Signed and sealed revised sheets to include A2.0, A2.2, A3.0, E1.0, E1.1, E2.0, E2.1, E3.0, and M1.0 3 Building Department Narrative Letter 1 Fire Rescue Narrative Letter Message The above items are being submitted in response to the review comments that we received. If there is any additional information .that you may need or if there are any questions or comments that you may have, please feel free to contact me at your convenience. Thanks in advance for all of your help & have a great holiday season! If enclosures are not as noted, please contact sender Copies 01 Transmittal 02.06.06 P:I2007\200702080\999 General Correspondencel200702080 Transmittal from Karla J. Sherrell 10 City of Zephyrhills 2007-12-21Adoc ~ 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404 601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALlAS NEW JERSEY ST. PETERSBURG December 21, 2007 To City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 813.780.0020 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 Re NAPA Auto Parts - Building Permit Comment Responses To Whom It May Concern: Below are outlined our responses to comments we received on December 13, 2007: Comment #1 - Nothing is to be built or installed in R.OW. with out the R.OW. use permit. Response - We shall comply and adhere to this requirement Comment #2 - Building to be 8 inches above the crown of the road or to the specifications of an approved engineered site plan. Response - We will be building the site based on the civil plans approved by the City of Zephyrhills Comment #3 - Compaction test required Response #3 - A compaction test will be performed as required by the City of Zephryhills Comment #4 - Batter-board survey will be required Response #4 - A batter-board survey will be performed as required by the City of Zephyrhills. Comment #5 - All block wall shall be inspected in lifts of at least 12 feet. Response #5 - A block wall inspection shall be performed as required by the City of Zephyrhills. Comment #8 - All setbacks shall be met. Response #8 - All set backs shall be adhered to and will be in accordance to with civil plans approved by the City of Zephyrhills . Comment #7 - All welds shall be inspected by an independent inspection agency and the reports shall be turned in to the Building Department. Response #7 - An independent agency shall provide all required weld inspections. The results of these inspections shall be forwarded to the City of Zephyrhills Building Department as required. Comment #8 - All A.DA (Chapter 11 of the F.B.C.) codes shall be met. Response #8 - We shall comply with the requirements of the aforementioned code. Comment #9 - All signage shall be in accordance with ordinance #870-04. Response #9 - All signage shall meet the requirements of City of Zephryhills Ordinance. 01 Project Letter 07.01.05 P:\2007\200702080\999 General Correspondence\200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21A.doc Also, we have made some additional change to the drawings based on our internal reviews. These changes are outlined below: A2.2 - Updated the floor finishes in the Electrical room (106), the restrooms (108 and 109), and office (105), from sealed concrete to burnished concrete. A2.2 - Added additional notation to provide plywood backing to the walls in the Electrical Room. E1.0 - Modification has been made to Electrical Panel Schedule due to a modification to the site lighting. E1.1 - Modification has been made Electrical Site plan with regard to the number of heads mounted on the site light poles. E2.0 - Modification has been made to the Electrical Symbol Legend with regard to the site lighting fixture. E2.1 - A detail has been added showing the method for mounting lighting fixture on the interior of the building E3.0 - The circuitry at the rear door has been modified from A-38 to A-7. M1.0 - A note has been added requiring the mounting of the air handling unit to be mounted at 15'-4". Thank you so much for all of your help with this review. If there are any questions or additional comments that you may have please feel free to contact us. 01 Project Letter 07.01.05 P:I2007\2007020B0\999 General Correspondencel200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21A.doc 14:30 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t:404 6014000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK . CHICAGO LOS ANGELES BOSTON DAlLAS NEW JERSEY ST. pmRSBURG December 21,2007 To City of Zephyrhills Buildin~ Department 5335 8 Street Zephyrhills, Florida 33542 813.780.0020 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 Re NAPA Auto Parts - Building Permit Comment Responses To Whom It May Concern: Below are outlined our responses to comments we received on December 13, 2007: Comment #1 _ Nothing is to be built or installed in R.O.W. with out the R.O.W. use permit. Response - We shall comply and adhere to this requirement Comment #2 _ Building to be 8 inches above the crown of the road or to the specifications of an approved engineered site plan. . Response - We will be building the site based on the civil plans approved by the City of Zephyrhills Comment #3 - Compaction test required Response #3 - A compaction test will be performed as required by the City of Zephryhills Comment #4 - Batter-board survey will be required Response #4 - A batter-board survey will be performed as required by the City of Zephyrhills. Comment #5 - All block wall shall be inspected in lifts of at least 12 feet. Response #5 - A block wall inspection shall'be performed as required by the City of Zephyrhills. Comment #6 - All setbacks shall be met. Response #6 _ All set backs shall be adhered to and will be in accordance to with civil plans approved by the City of Zephyrhills . Comment #7 _ All welds shall be inspected by an independent inspection agency and the reports shall be tumed in to the Building Department. Response #7 _ An independent agency shall provide all required weld inspections. The results of these inspections shall be forwarded to the City of Zephyrhills Building Department as required. Comment #8 - All ADA (Chapter 11 of the F.B.C.) codes shall be met. Response #8 - We shall comply with the requirements of the aforementioned code. Comment #9 - All signage shall be in accordance with ordinance #870-04. Response #9 - All signage shall meet the requirements of City of Zephryhills Ordinance. 01 Project Letter 07.01.05 P:I2007\200702080\999 General CorrespondenceI2OO702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21A.doc Also, we have made some additional change to the drawings based on our intemal reviews. These changes are outlined below: A2.2- Updated the floor finishes in the Electrical room (106), the restrooms (108 and 109), and office (105), from sealed concrete to burnished concrete. A2.2 _ Added additional notation to provide plywood backing to the walls in the Electrical Room. E1.0 _ Modification has been made to Electrical Panel Schedule due to a modification to the site lighting. E1.1 _ Modification has been made Electrical Site plan with regard to the number of heads mounted on the site light poles. E2.0 _ Modification has been made to the Electrical Symbol Legend with regard to the site lighting fixture. E2.1 _ A detail has been added showing the method for mounting lighting fixture on the interior of the building E3.0 _ The circuitry at the rear door has been modified from A-38 to A-7. M1.0 _ A note has been added requiring the mounting ofthe air handling unit to be mounted at 15'-4". Thank you so much for all of your help with this review. If there are any questions or additional comments that you may have please feel free to contact us. 01 Project Letter 07.01.05 P:I2007\2007020801999 General Correspondencel2007020BO Project Letter from Kaila J. Sherrell to City of Zephyrhills 2Q07-12-21A.doc 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404 601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALlAS NEW JERSEY ST. PETERSBURG December 21, 2007 To City of Zephyrhills Fire Rescue 6907 Dairy Road Zephyrhills, Florida 33542 813.780.0041 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 Re NAPA Auto Parts - Fire Rescue Comment Responses To Whom It May Concem: Below are outlined our responses to comments we received on December 13, 2007: Comment #1 - Building construction shall be in compliance with the Florida Fire Prevention Code Response - We shall comply and adhere to this requirement. Comment #2 - Install knox box on front of building near entrance at a height of 6'. Location can be determined once construction is near the end by contractor and Fire Marshal. An application has been provided. Response - We have updated the A3.0 sheet to show a proposed location of the knox box, and provided a note directing the General Contractor to coordinate the location with the Fire Marshal. Comment #3 - Address on front units shall be 6" in height Response #3 - A note has been placed on the A3.0 sheet referencing this requirement. Comment #4 - Separate plans are required to be submitted to obtain a permit for the sprinkler system. Plans shall be in accordance to the edition (2007) of NFPA 13. Plans shall provide calculations, all details and specs. FDC or sprinkler system shall be a single 5" Stortz outlet with cap. Response #4 - Separate plans shall be submitted in order to comply with this requirement. Comment #5 - Plans are required to be submitted to obtain a permit for the alarm system for sprinkler monitoring. Plans shall be in accordance to the latest addition of NFPA 72. Plans shall provide battery calculations, all details and specs. Copy of certificate of monitoring company also will be required. Response #5 - Separate plans shall be submitted in order to comply with this requirement. Comment #6 - Plans are required to be submitted for any gas installation with all details and specs associated with the install. Response #6 - There is not any gas being provided to this site. Comment #7 - Extinguishers shall be relocated in upper area to location at either end by stairs. Lower level extinguishers shall be located: 1 at rear door, 1 at front area, 1 by electrical and 1 centrally located across from electrical. Response #7 - The extinguishers have been relocated per the aforementioned locations. Please see revised A2.0. 01 Project Letter 07.01.05 P:I2007l200702080\999 General Correspondencel200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21A_Fire Department Comments.doc Thank you so muc~ for all of your help with this review. If there are any questions or additional comments that you may have please feel free to contact us. 01 Project Letter 07.01.05 P:I2007\200702080\999 General Correspondence\200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21AJire Department Comments.doc 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404 601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALLAS NEW JERSEY ST. PETERSBURG December 21, 2007 To City of Zephyrhills Fire Rescue 6907 Dairy Road Zephyrhills, Florida 33542 813.780.0041 Project NAPA Zephryhills/Gall Blvd, FL Project # 20070208.0 Re NAPA Auto Parts - Fire Rescue Comment Responses To Whom It May Concern: Below are outlined our responses to comments we received on December 13, 2007: Comment #1 - Building construction shall be in compliance with the Florida Fire Prevention Code Response - We shall comply and adhere to this requirement. Comment #2 - Install knox box on front of building near entrance at a height of 6'. Location can be determined once construction is near the end by contractor and Fire Marshal. An application has been provided. Response - We have updated the A3.0 sheet to show a proposed location of the knox box, and provided a note directing the General Contractor to coordinate the location with the Fire Marshal. Comment #3 - Address on front units shall be 6" in height Response #3 - A note has been placed on the A3.0 sheet referencing this requirement. Comment #4 - Separate plans are required to be submitted to obtain a permit for the sprinkler system. Plans shall be in accordance to the edition (2007) of NFPA 13. Plans shall provide calculations, all details and specs. FDC or sprinkler system shall be a single 5" Stortz outlet with cap. Response #4 - Separate plans shall be submitted in order to comply with this requirement. Comment #5 - Plans are required to be submitted to obtain a permit for the alarm system for sprinkler monitoring. Plans shall be in accordance to the latest addition of NFPA 72. Plans shall provide battery calculations, all details and specs. Copy of certificate of monitoring company also will be required. Response #5 - Separate plans shall be submitted in order to comply with this requirement. Comment #6 - Plans are required to be submitted for any gas installation with all details and specs associated with the install. Response #6 - There is not any gas being provided to this site. Comment #7 - Extinguishers shall be relocated in upper area to location at either end by stairs. Lower level extinguishers shall be located: 1 at rear door, 1 at front area, 1 by electrical and 1 centrally located across from electrical. Response #7 - The extinguishers have been relocated per the aforementioned locations. Please see revised A2.0. 01 Project Letter 07.01.05 P:\2007\200702080\999 General Correspondence\200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21AJire Department Comments.doc Thank you so much for all of your help with this review. If there are any questions or additional comments that you may have please feel'free to tontact us. 01 Project Letter 07.01.05 P:\2007\200702080\999 General Correspondence\200702080 Project Letter from Karla J. Sherrell to City of Zephyrhills 2007-12-21AJire Department Comments.doc PERMIT APPLICATION DRIVEWAY PERMIT APPLICATION CONSTRUCTION WITHIN PUBLIC RIGHT-Of-WAY All information must be filled-in completely City of Zephyrhills 5335 8th Street, Zephyrhills, FL 33542 Telephone 813.780.0000 Fax 813.780.0005 CONTRACTOR: 70 (Be, 0efeYrYlUiec/ Company: Name: Contractor's Ucense #: Phone: Cell: E-Mail: Fax: ARCHITECT I ENGINEER: Name: Address: () State License #: - e TYPE OF DRIVEWAY RESIDENTIAL DRIVEWAY X COMMERCIAL DRIVEWAY _PUBLIC ACCESS DRIVEWAY DescriDtion of Proiect IT LENGTH OF DRIVEWAY ~WIDTH OF DRIVEWAY ~.W. jf/AgXCAVATION DEPTH ""j'-LINEAR FEET CURB CUT REOUIRED _YES --A..-NO CULVERTS NEEDED ( ) REINFORCED CONCRETE ( ) CORRUGATED MATERIAL ( ) BOX CULVERT ( ) OTHER (EXPLAIN) ~srRUcrION MATERIAL ASPHALT _CONCRETE HEADWALL REOUIRED? _YES LNO NOTICE TO APPLICANT: If actual work exceeds scope of this description, additional permits or drawings will be required. UTILITY LOCATIONS REOUIRED: CALL BEFORE YOU DIG: 1.800.432.4770 Page 1 of 3 PERMIT APPLICATION UTILmES LOCATE CONFIRMATION NUMBER: 7f3JJ PROVIDE SKETCH IN THIS AREA, IF ADDITIONAL SPACE IS REQUIRED, ATTACH TO THIS APPLICATION. ?I~6L <Jef ttt/ached C. /. / and uvrvJ ~ C(J menk-/; ~ rV . AFFIDAVIT: Application is hereby made to obtain a permit to do work and installations as indicated. I certify that all foregoing information is accurate and that all work will comply with all applicable codes. I understand these codes shall take precedence over all approved construction documents, and issuance of this permit is verification that I will notify the property owner of Florida Lien Law req., F.S. 713. The issuance of this permit does not ensure compliance with deed restrictions and I understand that additional deed restrictions may apply to this property. All work shall comply with the current Florida Building Code, Public Works Design Manual and FDOT Design Standards (if applicable). (Public Works Design Manual online link: www.ci.zephyrhills.f1.usjpublic_works.asp) APPLICATION IS VOID UNLESS SIGNED WITH PROPER IDENTIFICATION AND WITNESSED BY A PERMIT TECHNICIAN OR NOTARY PUBLIC. NOTE: The City of Zephyrhills is not responsible for maintenance or repairs of driveways. Driveways shall not alter I interfere with existing stormw er treatment and I or conveyance. PROPERlY O~: By signing this application: Ice' that I have read and understand the owner/builder disclosure statement.~(Please initial) / 13 /O~ Applicant Print Name Dati! I /k/(7O- Date" as identification. (type of identification) Page 2 of 3 NollIry PubIlc. Cobb Countr. GeorgIa My Comml&slOn Expires Jurre 20. 2010 PERMIT APPLICATION OFFICE USE ONLY PUBUC WORKS USE ONLY Concrete (min. 6") y N --.............. " Asphalt Base (min. 6'') y N '\ \ Asphalt (min. 1 V2'') y N Length (min. 19') Y N I / Width (10' min - 20' max) y N / I Existing sidewalk. Y N l New sidewalk. Y N \. . " kJ /.. ADA compliant. Y N ~ /fI. / Expansion material required. y N { \ Contiguous parking pad. y N \. \ Triangular flare (3'W x 7'L) y N \ \ Visibility triangle o.k.? y N J / Side set back (3' min. R.O.W.) Y N /' /' Plan Review Fee Permit application approved by: Date: Page 3 of 3 1430 West Peachtree Street, NW Suite 200 Atlanta, GA 30309 t: 404601 4000 f: 404 601 3970 GreenbergFarrow ATLANTA NEW YORK CHICAGO LOS ANGELES BOSTON DALLAS NEW JERSEY ST. PETERSBURG January 2, 2008 Mr. Shane LeBlanc City of Zephryhills 53358th Street Zephyrhills, Florida 33542 Re Driveway Permit Application - NAPA Auto Parts - 6901 Gall Boulevard Dear Mr. LeBlanc: Enclosed with this letter is our application for a Driveway Permit and its supporting documentation. Upon your review of the enclosed documents, you will see that we intend to utilize the existing driveway at this site and accordingly do not anticipate doing any work in the Right of Way. Thank you in advance for you help with this review and, if you should have any questions or need any additional information please do not hesitate to contact me at your leisure. Happy New Year! ( 01 Formal Letter 07.01.05 P:\2007l200702080\999 General Correspondence\200702080 Formal Letter from Karla J. Sherrell to Mr. Shane LeBlanc 2007-12-27 A.doc '-. :....~ _' 1 ., ,',' . ~ ,'- --:':-" ~. ,.~ ' , :.:- \' =- .....,.- -"~' - - ~" ~. ,,-.,. ~""'" e .- i .-t I 1,1 , ,- I . , . L.L..J P. o ---.... 0 '.'~' 'LI- a u) '-'--.. (:;C):' ._--._-.. - ._- . -.-.-../> T''" J- ~._--;-~~_.- ,U "(' "\ ," "-J ~ ,-::-/~...._- - ._---~:_q_. -,-~- -~._- --. - -",. ~ . ,-' ...-- _/~- - <.':~ RIP RAP' AtbUTFALL . SEE DETAIL SHEET C':"6.1 .' ~ - -:- ----r - - __ r.:: - 1- - ,... 87.00 - - -- .... I 10' DRAINAGE d. 85.00 ___-86.0(}- - -------- , EASEMENT --t..:..:----;=.=~------- --.-:;..-..::.. - - - - --: -.-: --=-.- I ----~-- - . .- ~. ----..:-=~---- -~ - ~ .. 1 _' ----. -- - ~~.Q(')'- a~.Q(');.:;/" ___ [] ------- - ',' 0__--- _9----.- '* 87.57 f------------ - ,86.85 TC 87.07 88 3 C. w' ' 86.35 G 87. G ~ ~ '8 .' . , (', :r, 2.66% , f.i; N 1 (85.00 86,72 TC ~- o 0 86.22 G b ~ 1 o "'85.80 TC- :z 85.30 G . DWCl g , ,^, : TOP= ,85,53 g ~l - 10' -DRAINAGE Os: : EOP ElEV: 85,03 .-: 2.06% . INV ELEV.- 81.80, ~- EASEMENT :,~~--------=-=:7~-f--~ti5,03 86~13 G : '" ".- - - - - -. 45-. -. -LF- -1':'8~ -~-C.-p'-.,..:.~::...,l, - ~~ 1 ~i /. c" 86.40 Te 86 60Te " . ~. 87. 7~~'~~J~:~8 r: ~~:~~ r: 88.03 sw 88.39 sw _ ", .1 ~~ U.-S, \~5.90 G 8610 G N....8.~6Q.G- - - )}8., ,SW _ ~~,8.1.SW .....' ~7.71 SW. . _, '8~-- ' ; @4%_: ,,~., .--.'1 .-: ,I, .... : ~ ~ - 0 [] 02 ~ \ c9~oo 88.0 87.71 sw.- . H-.ll.93 SW 88.2 85 94 TC 86.12 .TC . . \:" ..I:.~. 87.10 G .11 G 87.43 G 87.1 I 85:44 G 85,62 G' \0 - /\~ 8.> a ~' . ~~.45~:s:i:5.53F:lt~nt .... ,. '. - - - B6.7~~ ~-- HANDICAP N89"5?' 4 ?"W RAMP AT CURB 346.97 RETURN. SEE DETAILS IN THIS SHEET. .. -- -- / ~ ,/ ~,-....-- - ~- \~ " ~ .~ >,," -.~. __ J r~~_ -< , I -- -- -_.~-~ ~ - -- -' ......',., ""-, ~ -- - ........ -- ------ --- , . ~,,-~ ....-'<... ' --- c.o. 8- PVC WYLCONNECTION WITH CLEANOUT 8- PVC @D ..' / INY ELEV.-86.00'" 0) O'l g ~ o. o 3% ~. #- .87.7 FG 3% ~.. . e~. ..,.,.. "'.'>< .'<. j" ':~:~;- \ ''\.... C") :--', r--'\ -- . .. _ 1< . :.. .. ., - ___'_~tt-" -::y, j A , ~ .... GENERAL GRADING/DRAINAGE NOTES: 1. ALL GRADING AND SITE PREPARATION SHALL CONFORM WITH SPECIFICATIONS CONTAINED IN THE GEOTECHNICAL REPORT. 2. ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE TO THE CllY lATEST CONSTRUCTION SPECIFICATIONS AND DETAILS. 3. PRIOR TO ANY EXCAVATION OF THE PROJECT SITE, THE CONTRACTOR SHALL NOTIFY THE CllY 48 HOURS PRIOR TO THE START OF CONSTRUCTION. 4. THE CONTRACTOR SHALL CAREFULLY PRESERVE BENCHMARKS, REFERENCE POINTS AND STAKES. 5. ALL INDICATED ELEVATIONS ARE FINISHED ELEVATIONS. 6. FIELD VERIFY LOCATIONS, SIZES AND IF APPLICABLE INVERTS OF EXISTING UTIUTIES FOR PROPOSED CONNECTIONS PRIOR TO CONSTRUCTION. 7. LOCATE AND PROTECT ALL UTIUTIES ASSOCIATED WITH THE PROJECT PRIOR TO CONSTRUCTION. 8. INSTALL SILT CONTROL MEASURES BEFORE BEGINNING SITE WORK. THESE MEASURES SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION. 9. MAINTAIN PROPER SITE DRAINAGE AT ALL TIMES DURING CONSTRUCTION. PREVENT STORM WATER FROM RUNNING INTO OR STANDING IN EXCAVATED AREAS. 10. INSTALL ALL APPROPRIATE TREE PROTECTION MEASURES PRIOR TO GRADING. 11. CUT AND FILL SLOPES SHALL HAVE A MAXIMUM SLOPE OF 2:1. 12. ALL EXCAVATION SHALL INCLUDE CLEARING, STRIPPING AND STOCKPILING TOPSOIL, REMOVING UNSUITABLE MATERIALS, THE CONSTRUCTION OF EMBANKMENTS, CONSTRUCTION FILLS, AND THE FINAL SHAPING AND TRIMMING TO THE THE LINES AND GRADES SHOWN ON THE PlANS. 13. ALL TREES, BRUSH, AND ORGANIC TOPSOIL AND OTHER OBJECTIONABLE MATERIAL SHALL BE REMOVED, UNLESS OTHERWISE SPECIFIED, AND DISPOSED OF AT AN Off-SITE LOCATION, WITH THE EXCEPTION THAT ENOUGH TOPSOIL SHALL BE RETAINED FOR RESPREAD AND GENERAL lANDSCAPING. AREAS WHICH ARE TO BE FILLED SHALL BE COMPACTED TO A MAXIMUM DENSIlY OF 95% AS DETERMINED BY THE MODIFIED MSHTO COMPACTION TEST IN THE PAVED AREAS AND 85% IN THE OTHER AREAS. 14. STRIP AND STOCKPILE TOPSOIL SPREAD FOUR (4) INCHES MINIMUM OF TOPSOIL ON lANDSCAPE AREAS AND REMOVE EXCESS TOPSOIL FROM SITE. PREPARE SUB-GRADE FOR PAVEMENT AND CURBS AND BACKFILL CURBS AFTER CURB CONSTRUCTION. 15. PROVIDE SUPPLY OF TOPSOIL FOR lANDSCAPE CONTRACTOR FOR INSTALlATION IN ALL lANDSCAPE ISlANDS. 16. PROVlDE AND INSTALL TOPSOIL IN DISTURBED AREAS TO BE GRASSED, TO INCLUDE PAVEMENT SHOULDERS AND DffiNllON AREAS. 17. ALL EARTHWORK AND BASE COURSE FOR THE PARKING AREA SHALL BE COMPACTED TO A MINIMUM OF 95% MODIFIED lABORATORY DENSllY. CERTIFICATION SAID COMPACTION SHALL BE SUBMmED BY THE CONTRACTOR TO THE ENGINEER, OR HIS/HER REPRESENTATIVE, PRIOR TO THE PlACEMENT OF THE BASE COURSE MATERIAL BOTH PROOF ROLLING AND COMPACTION TESTING MUST BE APPROVED AND WITNESSED BY THE ENGINEER OR OWNER REPRESENTATIVE. 18. THE PAVEMENT SUBGRADE AND BASE COURSE MATERIAL SHALL BE INSPECTED AND APPROVED BY THE ENGINEER OR OWNER REPRESENTATIVE PRIOR TO CONSTRUCTING THE BASE AND SURFACE COURSES THEREON. 19. CONTRACTOR SHALL PROVlDE POSITIVE DRAINAGE TO ALL INLETS AND CATCH BASINS. AREAS OF SURFACE PONDING SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER. 20. IF AREAS ARE DISTURBED BEYOND PROPOSED GRADES BY NEGLIGENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR NN REGRADING OR REPAIR TO MATCH ORIGINAL EXISTING CONDITIONS. 21. SHORING SHALL BE DONE AS NECESSARY FOR THE PROTECTION OF THE WORK AND FOR THE SAR1Y OF PERSONNEL. SHORING SHALL BE IN ACCORDANCE WITH ALL O.S.H.A AND LOCAL REGUlATIONS. 22. STRUCTURES FOR STORM SEWERS SHALL BE IN ACCORDANCE WITH THESE IMPROVEMENT PlANS AND THE APPLICABLE STANDARD SPECIFICATIONS. WHERE GRANUlAR TRENCH BACKFILL IS REQUIRED AROUND THESE STRUCTURES, THE COST SHALL BE CONSIDERED AS INCIDENTAL AND SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE FOR THE STRUCTURE. 23. CONFlRM INVERTS OF ALL EXISTING STORM INLETS AND SANITARY SEWER MANHOLES BEFORE COMMENCING CONSTRUCTION. 24. ALL STORM SEWER LINES 18--54- DIAMETER ARE TO BE REINFORCED CONCRETE PIPE ACCORDING TO ASTM C-76 lYPE III, UNLESS OTl1ERWISE SPECIFIED ON PlANS. 25. A GEOTEXllLE MATTlNG (lANDLOCK TRM 450 OR EQUIVALENT) SHALL BE USED FOR EROSION CONTROL AN ALL SLOPES GREATER THAN 3H:1V. 26. DRAINAGE STRUCTURES AND DETENTION POND SHALL BE MAINTAINED BY PROPERlY OWNERS. 27. CONTRACTOR SHALL ADHERE TO PROPOSED GRADES ALONG CREEKS, ESPECIALLY IN THE AREA OF THE PROPOSED DETENTION POND. IF AREAS ARE DISTURBED BEYOND PROPOSED GRADES BY NEGLIGENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY PENALTIES INCURRED. 28. ALL PROPOSED SPOT ELEVATIONS SHOWN INDICATE FINISHED GRADED ELEVATIONS AT EDGE OF PAVEMENT AND/OR GRADE BREAKS, UNLESS OTHERWISE NOTED. 28. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION. :-: XXXX EX :-: XXXX FG :-: XXXX TC :-: XXXX TW :-: XXXX SN :-: XXXX G PVC 0 0.75% 8-,PVC WYE CONNECTION WIll1 CLEANOUT 8- PVC WYE CONNECTION WITH CLEANOUT 8- PVC INY ELEV.= 87.04 . WYE CONNECTION WITH CLEANOUT \ COORDINATE ROOF' DRAIN CONNECTION LOCATIONS WITH ARCH. PlANS lYP 95 SW 89.45 SW <1" , ,'.ok 'lIN. !lLClPI COHaIE1E aRI- ~ ,. lit! SlJIlf"1llZ at ~ SHALL HA'" A _ IRXlIlEIl SlJIlf" ACE lD<1URE IIOU<HII lHAIC 1lC lIUllRQUKlIHO 9I)[WAU(, Z. lit! IlOTTOll at lit! RAW SHALL HA'" A MAXU.IIl at A 1/4' lJ'. 3. CQlS1RUCT Pel AJJ.A. STAHllMllS. SEE NOlI: , NOnS: CD .. ~ II ~ . ,A A r PAVF1H/'U...J , , , , . . . I."'" .. - , . .' ~ .' GRADING/DRAINAGE KEY NOTES: . ' !I.lPI: 1O FIT "'========- G7 DOUBLE WING CURB INLET (DWCI). FDOT DESIGN STDS INDEX 1210 -INLET TOP lYPE 4 WITH lYPE P BOTTOM. SEE CML DETAILS. c.o. o ':'2 MAX. AT CURlI ~aR1 PLAN 1\lP at ftNI11 --1 L4'_ USE IIROOIII fHSH ON LOPIlO POR11ON at IWoP -.EN l.OCA lED IN lit! OCNTER r:JI CURB RE1\JRN PVC CLEANOUT. SEE DETAIL SHEET C-6,O ---- XXX)( ---- ~ SECTION A-A WHEEL~HAIR RAMP IN SI~EWALK AT CURB RETURN N.T.S. PROPERlY LINE PROPOSED CURB & GUTTER PROPOSED CONTOUR PROPOSED STORM SEWER PIPE 24 HR EMERGENCY CONTACT: FRANK DEL CASALE: 770.956.2609 DRAINAGE SLOPE AND DIRECTION EXISTING SPOT ELEVATION FINISHED GRADE TOP OF CURB TOP OF WALL TOP OF SIDEWALK GUTTER GRADE BREAK / SHALE 48 HOURS BEFORE YOU DIG CALL SUNSHINE 1-800-432 -477 IT's THE LAW IN FLORIDA ',:J;" - --.- -- --.- - . - - -- l __, ; :'1 .:I ~>., ' ~ '<r. - ,<"- :~~, , . .u _ ~ .__ __._. ..'-~ ~',~-::..:~~.'''"-''-' --.--..-." _ _~ _ .~ ......:.._t..-_ -.......... -.. --- , ~.- ~ -- --- ~ 'f-,,, f"''''''' '".",,,1 (~ '4f ",-' ;> . V) 1--. . h:) ",i <), \~:?:~: ! -..--.--- "'.~_. . '-. ~ <' >( 1"-" '> / ,-i:) f' A",,--); / / ('\.' l r....:." ;', .?~ 'r='&~'~::<~i'<:~'1.::~:'\~";"~~\ . ,,~ ~ ..-"'1' ~ ",.'\ - ~ ~O;\ ~ -~ r I . \ - , ; , 1- ~ -~~..... ------ 'I 1 '._. 1_"."'. C'-, - -~-- t--,'" ,~;.,~ '~t~:: rr- ~: <t ~~ > f~~.~ c,,~) },~~'0'~~ hI~" ~."..,.. --------- Vj W ~ ;:;::--- C,.) 0:::::: ----.~ ;:r< " ~ , ~:NfEA I~ ~) ~I =~ t NOnS: ~-~-+-~-r::=l-'-+-'--1 " =~~ rSl:EWJUf. Ill.t.DIHO RAW Elf'_JaNTIlA~ ~~ ~ AIlolAOO<T 1O 1lIAllI<<i(TiP.) \ z. lit! IlOTTOll at lit! RAW SHALL HA~ A llAXUJIl 1. at A '/4' lJ'. 3. CQlS1RUCT Pel A.lI.A. STAHllMllS. -, WHEELCHAIR RAMP IN SIDEWALK N.T.S. Ci\~ of l~phyrbJ1.~ Slto: Plan R",;,,;,... Ap\:f,)ya! " l,;.:~ i').,t:!1-; :/1bO-'Ili 0 7 AppfuLl 'I"~ cI J .'. ~'. . 13y._;dll/~L ,._. ~..--, ( Di~'~..,.\ ,,' ), '_" . ~/ \ . !r....-" ;. SiteP1d.nR;;\,;, r~(lJ)'~ }}.'\r~__.. ,__._ ,'p" :Jl~. _..__. ./ ~ 10 1 [OJ G11 MITERED END SECTION. FOOT DESIGN STDS INDEX #272 FOR SINGLE ROUND CONCRETE PIP'E. SEE CIVIL DETAILS. G14 MATCH EXISTING ELEVATION PROPOSED LEGEND: GRAPHIC SCALE 20 l 40 b. ( IN FEET ) 1 inch = 20 fl O~.- 7Ss~a "", ..:; c~. )>"~C~ ~< ~ ~ u ~ 80 ~ Greenbergfarrow 1430 W. Peachtree St. Ste. 200 Atlanta, GA 30309 t: 404 601 4000 f: 404 601 3990 PROJECT TEAM ;:~ OJ COPYRIGHT NOTICE This draw'ng is :he property of the oboye referenced Professional and is not to be used for a'iY purpose other than the specific project and site na'1'1ed hereir, ard carrot be reprodl~ced ;n ony monner without :re express w:itten permiss;on from the Profess;onal ISSUE/REVISION RECORD DATE DESCRIPllON 07/27/07 SUBMITTAL TO CITY AND S~D 08/20/07 2ND SUBMITTAL TO CITY 08/29/07 2ND SUBMITTAL TO S~D 10/12/07 3rd SUBMITTAL TO S~D 11/21/07 3RD SUBMITTAL TO CITY ....v_ " -~;~ . ")~'J07 CERTIFlCATION OF AUTHORIZATION , NUMBER: EB0007559 JOHN NOURZAD PROFESSIONAL ENGINEER LICENSE NO. 53398 ,', .",,;to,' r:~ PROFESSIONAL IN CHARGE JOHN NOURZAD PROJECT MANAGER KE.V1N PRUEMER QUALITY CONTROL ROD ABN EY DRAWN BY JOSH YOO PROJECT NAME NAPA ZEPHYRHILLS 1 .. " ZEPHYRHILLS FLORIDA 6855 GALL BOULEVARD (A.K.A. U.S. HWY_ 301) PROJECT NUMBER 20070208.8 SHEET TITLE GRADING PLAN SHEET NUMBER C-3.0