HomeMy WebLinkAbout08-7336
1IIIItI]
01 WOMEN€;
r HANDICAP
3' 4"
&' 0"
3' 10"
~
-~
.'." []
18' 11"
Q
't
o
M
o
M
OFFICE
EXl6TING RE6TROOM FLOOR PLAN
1/4" = I' 011
DIMENSIONS> ARE APPROXIMATE AND MUST
BE FIELD VERIFIED B,,( CONTRACTOR
GENERAL NOTE5,
(I) RELOCATED EXI5TING WATER I-iEATER ABOVE
EXI5TING DROP CEILING.
(2) REMOVE 5TORAGE CL05ET AND FILL DOOR
OPENING (C).
(3) REMOVE EXI5TING DOOR (A) AND (B) AND ENLARGE
OPENING5 TO ACCOMADATE 3'0" DOOR5
(4) REMOVE EXi5TING DOOR (D) AND REPLACE WITI-i NEW
3' 0" DOOR A5 51-i0WN. MOVE WALL IN THi5 AREA TO
ENLARGE RE5TROOM TO MEET ADA REQUIRMENT5.
(5) REMOVE EXI5TING DOOR (E) AND CL05E OPENING5.
(~) REMOVE EXleTING DOOR (F) AND REPLACE WITH NEW
3'0" DOOR Ae 5HOWN,
(1) REMOVE EXI5TING DOOR (G) AND MAKE CL05ET
eMALLER TO ACCOMADATE NEW DOOR (F), INeTALL
NEW 3'0" BIFOLD DOOR A5 5HOWN ON CL05ET,
(6) EXI5TING RE5TROOM5 I-iA DROP CEILING.
(~) NEW WALLe WILL BE CONeTRUCTED FROM FLOOR
TO ABOVE DROP CEILING.
(10) DROP CEiLING GRID 5"(5TEM AND L1GI-iTING l1ILL
BE RELOCATED TO ACCOMMODATE RENOVATION5,
(II) ADD NEW EMERGENCY LIGHTING A5 5HOWN IN
RE5TROOM AREAe,
M) NO ADDITIONAL LOAD TO EXI5TING MECHANICAL
5'r5TEM. MECHANICAL CONTRACTOR TO AD)J5T
DUCTe AND VENTe TO ACCOMADATE RENOVATION5.
WOMEN€;
(E)
3' 8"
4' 8"
3' 10"
(B)
11' 8"
WOMENO. - - _
HANC>(CAP
I
Q
"'t
,
,
"
,
,
,
\
\
I
I
,
I
I
I
I
I
./
I
I
I
I
,
\
\
,
,
g
....---....
~
OFFICE
RENovATED RE6TROOM FLOOR PLAN
1/4" = 11 0"
DIMENSIONS> ARE APPROXIMATE AND MUS>T
BE FIELD VERIFIED B"( CONTRACTOR
V//////////////////J
EXI5TING INTERIOR WALL
NEW INTERIOR WALL
o
::t
1~' 8"
: :,
I I
I I
~-----~
EXieTINQ AC. VENT
TO 6E i<ELOCA TED
EX[€;TING
CONFERENCE ROOM
EXI51lNG 5TORE FRONT GLA55
EXI5TING OFFICE FLOOR PLAN 1/4" = I' 0"
DIMENSIONS> ARE APPROXIMATE AND MUST
BE FIELD VERIFIED B"( CONTRAcrOR
GENERAL NOTEe,
(I) EXI5TING OFFICE AREA I-iA5 DROP CEILING.
(2) NEW WALL WILL BE CONeTRUCTED FROM FLoeR
TO ABOVE DROP CEILING.
(3) DROP CEILING GRID 5"(eTEM AND LIGHTING ll,ILL
BE RELOCATED TO ACCOMMODATE RENOVAlION5.
(4) ADD (2) RECEPT ACLE5 IN NEW WALL AT EAOI elDE
AND RELOCATE EXI5TING LIGI-iT FIXTUREe IN DROP
CEILING Ae NEEDED. ADD ADDITIONAL 5WITCI~ FOR
LIGI-iT FIXTURE IN OFFICE .2, ADD EMERGENCY LIGI-iT
FIXTUREe iN EACl-1 OFFICE,
(5) NO ADDITIONAL LOAD TO EXleTING MECl-1ANICAL
5Y5TEM, MECI-iANICAL CONTRACTOR TO ADJ.I5T
DUCT 51ZE TO ACCOMMODATE EXleTING OFFICE
BEING DIVIDED IN TO TWO 5EPARATE OFFICE5
F ADDITIONAL
. _ _ _ _, A.C. VENT . _
I I I
I I I
I I I
I I 1
I I I
~_____.1 L;'"
~' 10"
I OFFICE 12 I
EXleTING 5TORE FRONT GLAee
EXI5TINGr WALLe
EX[€;TING ENTRANCE
LOBBY AREA
(l
8
a
~
~
z
~
~
EXleTING 5TORE FRONT CrLAe5
EXleTING 5TORE FRONT GLAe5
EXI6TING ENTRANCE t\REA FLOOR PLAN 1/4" = I' 0"
DIMENSIONS> ARE AFPROXIMATE AND t-1U~T
BE FIELD VERIFIED B,,( CONTRACTOR
j-, ._----,
EXleTINQ A.C. '.~r
TO 6E RELOCAEO ~' ro"
F RELOCATE
A.C. VENT
r-----..
I I
I I
I , =
I I ()
I I
I OF:=ICE II
EXleTING 5TORE FRONT GLA5e
~1
-~
~
:t
!\PPH.C}VED
, "11
11" ':~ire lvlilr~',hal of Zepnyrm. S
Ni~r enfVi~~\~lW(Sl
:@
OFFICE RENOVATION FLOOR PLAN 1/4" = I' 0"
V////////////////////////J
EXleTING INTERIOR WALL
NEW INTERIOR WALL
=
54" MIN TOILEr
PAPER
HOLDER
42" MIN
I: _%
<<,. :~
,
LAV:
I
I I
'" - - - --,
I
I
I
,
I
I
I
I
~
.~
~
.
G1
CLEAR FLOOR
eFACE
I-lANDICAF TOILEr DETAIL
-------------------~
60" MIN
GRA6 6ARe
A CoRAe BAR Si-lALL BE FRovIDE. LOCATED ~~' INCi-lES>
FROM AND PARALLEL TO TI4E FIN/e~ED FLOOR. MEAWRED
VERTICALL"( TO TI4E TOP OF TI4E RAIL WITi-l VARIATION OF
NOT MORE THAN 112 INCH AND,
I. eHALL HAVE AN OUTe,IDE DIAMeTER OF I 1/2 INCHE5
2. e,HALL FROvlDE 1 1/2 INC14E5 OF CLEARANCE BETWEEN
THE RAIL AND THE WALL.
~, e,HAlL BE 50 DEe/CoNED AND &UFPORTED AS> TO WITH5TAND
A LOAD 01" NOT LEe5 TI4AN 2SO L65 AFPLIED AT AN'r POINT.
DOWNWARD OR HORIZONTALL"(,
4. e,HALL BE CONTINUOUe,L"( CoRAePABLE ALONCo THE ENTIRE
lENQTI4.
eFEC/AL NOTE, CoRAe BAR MEeTlNCo TI4E AFPLICABLE ANe,1 eT ANDARDS>
ARE DEEMED TO BE IN COMPLIANCE WITI4 TI4E INTENT OF
TI4E LAW WHETI4ER CENTER &UFPORTe, EXleT OR NOT,
S. eHALL BE AT lEAS>T 42 INCHEe lONCo AND e,HALL BE CENTERED
AT TI4E LEADINCo EDCoE OF TI4E WATER CLOe,ET.
N
3: 0)
,... 0
0:: 0 C?
I ,...
, " 0
EXleTINQ >- 0
WALLe ~ :E
al I
0
Z ~ "
3: ' " 0
W Z
~ I- en
~ 0
C C ..,
(l
0
0
a
~
~
~
Z
i=
tS)
~
DIMENSIONS> ARE A:~PROXIMATE AND MUS>T
BE FIELD vERIFIED B,,( CONTRACTOR
GENERAL NOTEe,
(1) EXi5TING ENTRANCE ",REA I-iAe DROP CEILING.
(2) NEW WALL WILL BE CCN5TRUCTED FROM FLOOR
TO ABOVE DROP CELlNCr.
(3) DROP CEILING GRID 5Y5TEM AND LlGI-iTING WILL
BE RELOCATED TO ACCOMMODATE RENOVATIONe.
(4) ADD NEW RECEPTACLEe A5 el-iOWN AND RELOCATE
EXI5TING LIGHT FIXTURE5 IN DROP CEILING A5 NEEDED,
ADD 5UJITCH FOR LIGI-4T FIXTUREe. ADD EMERGENCY
LIGI-iT FIXTURE IN ROOM.
(5) NO ADDITIONAL LOAD TO EXleTING MECI-iANICAL e'reTEM,
MECl-1ANICAL CONTRACTOR TO RELOCATED VENTe Ae
NEEDED TO ACCOMMODATE NEW CONFERENCE ROOM.
(~) FRAME OUT EXleTING WALL AND COVER EXI5TING GLA5e
DOOR.
EXI5TING 5TORE FRONT CrLAee
ADDITIONAL
'-F--' AC. VENT
I I
I I
I I
I ,
I I
,,-----...
ADDED 2X4 U:ALL TO
COVER EXleTINQ DOOR
WITH INOULATION
NEW 2><4 WALL
"'t:
-~ i
-!
NEW
CONFERENCE ROOM
20' 0"
:@
EXle.TING 5TORE FRONT GLA53
EXle.TING 5TORE FRONT GLAee
CONFERENCE ROOM ADDI.r10N FLOOR PLAN 1/4" = l' 0"
DIMENSIONS> ARE AFPROXIMATE AND MUS>T
BE FIELD VERIFIEl' B,,( CONTRACTOR
NEW INTERIOR WALL
-i
~
~
~
I:
~
11" MAX LAv DEPTH
~" MIN KNEE CLEARANCE
~ANDICAP SINK DETAIL.
SINK
I. e,INK e,HALL BE MOUNTED WITI4 THE COUNTER OR RIM
NO HICoHER THAN ;4" FROM THE FINlel4 FLOOR, EACI4
e,/NK eHALL eE MINIMUM OF eo 112" DEEP,
2. CLEAR FLOOR ePACE REeTRooMe el-lALL i-lAvE AN
UNOBeTRUCTED ePACE 01" AT LEAeT ~' IN DIAMeTER
OR S2' B"( 12" F/NleH INelDE DIMENelON5 ADJACENT TO
TI4E LAvATOR"( AREA. &UCI4 CLEAR FLOOR e,PACE e,HALI.
AD.JOIN OR OVERLAP AN ACCEeS>IBLE ROUTE AND e,l-lALL
EXTEND A MAXIMUM OF 1~" UNDERNEATi-l TI4E LAvATOR"(
OR e,INK
EX/&TINQ Rool"
\-(EVj
.:;!'.r(
.lS.
l \ ;,. ~
o
112" 2' X 4' DROP IN CElllNCr TILE
AND MET AI. QRID &,,(&TEM.
o
~ S/~' 2S CoA. METAL e,ruDe, WITI4 112' Co,,(P&UM WALL
BOARD EACH e,IDE. eECURE e,ruD WALL AT BOTTOM
THROUCoi-l MEEL TRACK WITI4 MAS>ONR"( ANCi-lORS>
TI4AT FENETRATE CONCReTE MINIMUM l' SPACED
24' OC AND AT TOP WITI4 ZIP FEAI. e,TRIP 6CREUJED
TO METAL CEIL/NQ TILE CoRID e,"(eTEM
o
o
TYPICAL. INTERIOR MeTAL STUD WALL. DeTAIL.
NO SCALe
,.j.'. .:I.il
1\' II:.
~i~
I '
0
f"- (/)
0 z
" N CJ
I
(.) f"- -
Z (/) I/) <D ffi
-(/)N I/) 0
I
"" ~ Lt) N
(/) 0. M Lt) ..J
~ >- M M ~
- co ~ ~ -
(.)
ffi (1,) 0 ~
ocna: L&J
Z ~o :E
...... :E
~ :z: rt f"- 0 SJ
!;;:cn~ 0 (.)
~ ,"--;
~ ::i C3 M ~ {'j'\
N ..J t---
>- t"t L&J Lt) ~
o NO I
N -
I- \
Z (1,) ~ Lt) Z
~ Me M L&J \~
O:::t"t L&J 0
(.) -
- (/) (:J
L&. L&J
La. 0:::
0
w
~
c
z
o
<i5
>
W
0:::
<(
c
><0:=
WO
(/)-1-1
ZD..u.
O:E "'
-O(/)
1-0-1
<((!):::!
>z:I:
o_~
Zl->
WWJ:
~~a.
~~W
O<(N
-:Eci
~I->
wZ-I
~Wal
-0-1
0-1
<(<(
(!)
PG
1 OF 1