Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
08-8586
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8586 FIRE ALARM SYSTEM PERMIT Permit Number: 8586 Address: 7920 GALL BLVD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-00700-0000 Improv. Cost: Date Issued: 12/10/2008 Name: PRIMERICA GROUP ONE Total Fees: 200.00 Address: 3629 MADACA LANE Amount Paid: 200.00 TAMPA FL 33618 Date Paid: 12/10/2008 Phone: (813)933-0629 Work Desc: INSTALLATION OF FIRE ALARM-BLDING B FIRE ALARM&SECURITY TECHN LLOGI FIRE ALARM 50.00 FIRE PLAN REVIEW FEES V 100.00 FIRE INSPECTION FEES .v 50.00 FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRACTOR SIGNATURE PJlThC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 �vv/L',LUu*//i J 11 : 4 A ZEPHYRHILLS BUILDING FAX No, 81 7811-0021 cz P. 001/001 813-7,80 0020 City of.Zephyrhllls fir =••. j Fax-8 - 80-0021 Permit Application {1 I Date Received7YJ 'Phone Contactfor Permit Owners Name Cprv�nnrotn,5. 11(\C . Owner's Phone Number Z C� Owners Address � o-k'e a .1�LQQ_ o Fee Simple Titleholder Name I (A.) -'1 1'\•v— I Titleholder Phone Number Fee Simple Ttleholder Address v lr �� 11l Y�1 Job Address Lot# ll /� —2$--Z1 oaoto.,Oo'7�—mop SrW ob. v NIW0n / Parcel# gs—21 —O_ a Blo-Hazard Waste Storege-ANNUAL Fumigation Tent •. ' Comm Exhaust Kitchen hood/Duct Hazardous Material(Tier ll or RO Faculty)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw •LP/Natural Gas-Installation � R �` Emergency Generator>30 kw • LP/Netttral Gas-ANNUAL Sala q �(YK 7?CtiU Q ' Fire.Protection Maintenance-ANNUAL Places of Assembly-ANNUAL .. em ®n er Sprinkler ❑ ❑ S.D ' Recreational Bum Fire Alarm .❑ O ° ❑ E Sparklers - Hood Cleaning p ❑ , O ❑ Sprinkler System Installations, Hood Suppression a' 0 :❑ ❑ El Standpipes(Sprinkler Sys) S �� Fire Alarm Installation a Torch Roofingfrar Kettle /� Fire Pumps Writs Tire Storage ANNUAL _ Fire Works { Flammable Application-ANNUAL. Valuation of Project Fuel Tanks • ' Other: Contractor • Company ►rNt Signature ' Registerer jY7 N Fee Current - N •Address -• u4 vg JzSi ot tense# " ELECTRICIAN ' 1 Company Signature Registered Y/N f Fee Current L Y/NJ Address License# PLUMBER S S S Company - Signature - Registered J Y-/N J Fee Current• L Y/N ! Address 'Ucense#. ' MECHANICAL Company S ' Signature Registered Y/N I Fee current Y-/N Address License# OTHER Company Signature . (Registered L Y/N j Fee current t :Y/N 1 . • Address S S Ucense# . Directions:. F111 out application completely. Owner&Contractor slgn.back of application;notarized(Or,copy of signed contract with owner) • If over$2500,a Notice of Commencement is requlred,(Mechanlcal work over$5000) Supply two(2)Bete of drawings with applicable documentation ' Allow 10-14 days for review affa►submittal date. Parcel#-obtained from Property Tax Notice(httpJ/approiser,pascogov.com) . ' d Zephy-rh fs Fire Rescue 6907 Dairy Road,Zephyrhills, FL 33542 Fire Marshal Bus(813)780-0041 Kerry Barnett Fax(813) 780-0044 E-mail: kbarnett({zfire.zephyrhills.f.us Plan Review#: 08-154 Project:Zephyr Commons Bldg"B"Fire Alarm Number of Pages: 1 —plus details packet w/calcs Date:November 28,2008 I have reviewed the plans for the fire alarm installation located at 7920 Gall Blvd and this installation can move forward.Paying for permit acknowledges contractor agrees with the items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. System shall be installed in accordance to NFPA 72,2007 edition. 2. Add outside horn/strobe located in red on plan. 3. There are 10 pulls located on plan,riser schematic shows 9.Adjust accordingly. 4. Devices shall be addressable.Pulls and ducts for each unit shall be addressed and . labeled as such to correspond at alarm panel. 5. Adjust battery cals for additional device.Batteries shall be dated. 6. Phone jacks shall be marked. 7. Breaker shall be labeled and locked off. 8. Zone map shall be located at alarm panel. 9. Strobes shall remain on when system is silenced. 10.Leave extra pull box key with alarm panel. 11.A copy of certificate for UL Listed Central Monitoring Company Inspection Required: 1. Acce T st KERB ARNETT,FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. FIRE SERVICE USER FEES Occupancy No.: Plan No.: r.ContractoI_t� ' `1` /i�Cff Business Name: it� Billing Address: Business Address: a,, Business Phone No.: Billing Phone No.: lsfr-.� �_l Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 site Plan we Annual N/C Sprkrwer $50 1st Alarm we .06 of 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-Inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-Inspection $250 $50 4th Alarm $100 4th Re Inspection $500 Fire Alarm 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200 0-25 Heads $50 violations corrected) Natural Gas $50 worn COMPUANCE $150 26p Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Spadders $100 0 Per Riser $50 Hydrostatic Test $65 persyaam Fire Works $500 FIRE PUMP Acceptance Test $45 pK eysam Camp Fire $25 0 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices FIRE ALARM S Place of Amy $50 Annual 26 plus Devices System Acceptance I Fire Protection $25 SUPPRESSION SYSTE Recall Acceptance Fiammabe A ye, $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annum Dry $50 Fare Wamoke Wan $15 perwee Generator<KW $100 CO2 $50 LP Gas $25 pelts,* Generator>30 KW 150 Other $50 Natural Gas $25 pe►syaam BIo-Hazazd Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 0 HoodlDucts $50 Terd 10x10 or greater $15 per ant Torch Pot/Appled $50 OTHER Fire Pump $45 Haz.Materials $100 Annum LP ln$QtfrIfl per tank $50 Fke Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Ethauat Hood/Duct $30 Natural Gas installation $50 Re-loon DBL (Per System) (other than annual) ❑Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours 8 Construction Insp. N/C Emergency Vehicle Ac' _� FALSE ALARM PLANS TOTAL - INSPECTION TOTAL PERMIT TOTAL TOTAL GRAND OTAL Comments: Date: ri Ins�Gtor. Fire Alarm & Security Technologies State Fire Alarm License # EF 20000480 www.fastdetection.com Project Building B Zephyr Commons Kossik and US Highway 301 Zephyrhills, FL Equipment Supplier Fire Alarm& Security Technologies 27251 State Rd. 54 Suite B-14/331 Wesley Chapel, FL 33543 Contact Tim Sorvillo 813-690-4104 SUBMrrrF,U PLANS} AV SEEN REV 27251 State Road 54 Suite B-14/331 Wesley Chapel FL. 33543 DF-52418:A•Al-60 MS-9050UD Are LT ALarmS Fire Alarm Control Panel by Hone` rell with DACT General The Fire•Lite MS-9050UD is a Fire Alarm Control Panel (FACP) and Digital Alarm CommunicatorITransmitter (DACT) combined into one circuit board.This compact,cost effective, intelligent addressable control panel supports up to 50 addres- sable devices of any type of detectors and modules. With an extensive list of powerful features, the MS-9050UD programs just like Fire•Lite's larger products,yet fits into applications pre- viously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include remote annunciators and reverse polarity/city box transmitter. (4XTMF) Features • Listed to UL Standard 864,9th edition. • Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. • On-board DACT • 20 software zones. • Two independently programmable Style Z (Class A) or Style Y(Class B)NAC circuits. NOTIFICATION APPLIANCE CIRCUITS(NAGS): Selectable strobe synchronization for System Sensor, . Two independently programmable output circuits. Circuits Wheelock,and Gentex devices, can be configured for the following outputs: • Remote Acknowledge,Silence,Reset and Drill via address- —Style Y(Class 8) able monitor modules. —Style Z(Class A) • Two programmable relays and one fixed trouble relay. —Door Holder Service • Integral 80-character LCD display with backlighting. —Aux Power Source • Real-time clock/calendar with automatic daylight savings . Silence Inhibit and Autosilence timer options. control. • Continuous, March Time, Temporal or California code for • History file with 500 event capacity, main circuit board NACs with two-stage capability. Detector sensitivity test capability(NFPA 72 compliant). . Selectable strobe synchronization per NAC. • Maintenance alert warns when smoke detector dust accu- • 2.5 A total power for NACs. mulation is excessive. NOTE,. Maximum or total 24VDC system power shared between • One person audible or silent walk test with walk-test log and all NAC circuits and the ANN-BUS is 2.7 A. printout. • Point trouble identification. PROGRAMMING AND SOFTWARE: • Waterflow(nonsilenceable)selection per monitor point. - Autoprogram(learn mode)reduces installation time. • System alarm verification selection per detector point. • Custom English labels(per point)may be manually entered or selected from an internal library file. • 72 c PAS (Pioe Alarm Sequence) and Pre-signal per point • Two programmable Form-C relay outputs. (NFPA 72 compliant). • Up to eight ANN-BUS annunciators. • 20 software zones. • Continuous fire protection during online programming at the SLC COMMUNICATION LOOP, front panel. • Single addressable SLC loop which meets NFPA Style 4,6 . Program Check automatically catches common errors not and 7 requirements. linked to any zone or input point. • 50 addressable device capacity (any combination of addressable detectors and modules). • Compatible with Fire-Lite's addressable devices (refer to SLC Wiring Manual). DF-52418A•04!05!07—Page 1 of 4 User interface BEAM355S: Intelligent beam smoke detector with integral sensitivity test. LED INDICATORS D350PL: Photoelectric low-flow duct smoke detector. • AC Power(green) D350RPL: Photoelectric low-flow duct smoke detector with Fire Alarm(red) relay option. Supervisory(yellow) MMF-300: Addressable Monitor Module for one zone of nor- Trouble(yellow) mally-open dry-contact initiating devices. Mounts in standard • Alarm Silenced signals(yellow) 4.0"(10.16 cm.)box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B KEYPAD (Class B)or Style D(Class A)IDC. • 16 key alpha-numeric pad. MDF-300: Dual Monitor Module.Same as MMF-300 except it • Acknowledge/Step provides two Style B(Class B)only IDCs. • Alarm Silenced MMF-301: Miniature version of MMF-300.Excludes LED and • Drill(Manual Evacuate) Style D option. Connects with wire pigtails. May mount in device backbox. • Reset(lamp test) MMF-302: Similar to MMF-300,but may monitor up to 20 con- Ordering Options ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. MS-9050UO: Combination DACT/Fire Alarm Control Panel CMF-300: Addressable Control Module for one Style Y/Z with one SLC loop. Includes main circuit board with display, (Class BIA) zone of supervised polarized Notification Appli- chassis with transformer, taming screws,cables,key,etc.,etc.,manual.backbox with door, plastic bag con- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC DP-51050: Optional dress panel for the MS-9050UD. to power notification appliances. TR-CE: Trim Ring for semi-flush mounting. CRF-300: Addressable relay module containing two isolated BB-26: Battery backbox, holds up to two 25 AH batteries and sets of Form-C contacts, which operate as a DPDT switch. CHG-75. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. BB-55F: Battery box,houses two 55 AH batteries BG-12LX: Addressable manual pull station with interface CHG-75: Battery charger for lead-acid batteries with a rating module mounted inside. of 25 to 75 AH. 1300: This module isolates the SLC loop from short circuit BAT Series: Batteries,see data sheet OF-52397. conditions(required for Style 6 or 7 operation). PRTIPK-CABLE: Cable printer/personal computer interface SMB500: Used to mount all modules except the MMF-301 cable. and M301. PRN-6F: UL listed compatible event printer. Uses tractor-fed MMF-300-10: Ten-input monitor module. Mount one or two paper. modules in a BB-2F cabinet(optional). Mount up to six mod- OPTIONAL MODULES ules on a CHS-6 chassis in a BB-6F cabinet_ 4XTMF Reverse Polarity Transmitter Module: Provides a MMF302-6: Six-zone interface module. Mount one or two supervised output for local energy municipal box transmitter, modules in a BB 2F cabinet(optional). Mount up to six mod- alarm and trouble. Includes a disable switch and disable trou- ules on a CHS-6 chassis in a BB-6F cabinet. ble LED. CMF-300-6: Six-circuit supervised control module.Mount one or two modules in a BB-2F cabinet(optional).Mount up to six COMPATIBLE ANNUNCIATORS modules on a CHS-6 chassis in a BB-6F cabinet. ANN-80: Remote LCD annunciator mimics the FACP display CRF-300-6: Six Form-C relay control module. Mount one or ANN-1/O: Input/Output Module for driving graphic annuncia- two modules in a BB-2F cabinet (optional). Mount up to six tors or relays modules on a CHS-6 chassis in a BB-6F cabinet. ANN-SIPG: Serial/Parallel Printer Interface module for con- NOTE_ 1) For more information on Compatible Addressable necting printer to FACP Devices for use with the MS-9050UD, see the following data sheets(document numbers):AD355(DF-52386), BG-12LX(OF- ADDRESSABLE DEVICES 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ All feature a polling LED and rotary switches for addressing. CRF Series (DF-52130), CP355 (DF-52383), D350PUO350RPL (DF-52398),H355 Series(DF-52385),1300(DF-52389),MMF-300 CP355: Addressable low-profile ionization smoke detector. Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- SD355: Addressable low-profile photoelectric smoke detec- 302-6(DF-52356),SD355/SD355T(DF-52384). tor. 2) Legacy 300 Series detection devices such as the AD355, CP300/CP350, SD300(T)ISD350(T) and older modules such as SD355T: Addressable low-profile photoelectric smoke detec- the M300, M301,M302, C304,and BG-10LX are not compatible tor with thermal sensor. with LiteSpeed polling. If the SLC contains one of these devices, H355; Fast response,low-profile heat detector. polling must be set for standard CLIP protocol.Please consult fac- tory for further information on previous 300 Series devices. H355R: Fast-response, low-profile heat detector with rate-of- rise option. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B35OLP base included).CLIP MODE ONLY BEAM355: Intelligent beam smoke detector. Page 2 of 4—DF-52418:A-04/05107 ADDRESSABLE DEVICE ACCESSORIES Power Supervision Relay: Supervises the power to 4-wire End-of-Line Resistor Assembly(R-47K and R-3.9K): 47k smoke detectors and notification appliances. ohm supervises the MMF-300, MDF-300, MMF-301, and N-ELR Mounting Plate: Single End-of-Line resistor plate CMF-300 module circuits. 3.9k ohm End-of-Line Resistor required for use in Canada. assembly supervises the MMF-302 module circuit. These resistors are included with each module. Wiring Requirements While shielded wire is not required,it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference.Wire size should be no smaller than 18 AWG(0.78 mm2)and no larger than 12 AWG(3.1 mm2).The wire size depends on the length of the SLC circuit.Use the following table to determine the specific wiring requirements for the SLC.(Refer to the panel manual for complete details.) CIRCUIT CONNECTIONS WIRE REQUIREMENTS Wire Type and Recommended Circuit Type Circuit Max.Distance Wire Gauge and Compatible Brands yp Function Limitations Feet(meters) 12 AWG(3.25 mm2):Genesis 4410, Signal 98230,Belden 9583,WPW999 14 AWG(2.00 mm2):Genesis 4408&4608 Twisted,shielded pair Signal 98430,Belden 9581,WPW995 40 ohms maximum per 10,000(3,000 m) 16 AWG(1.30 mm2):Genesis 4406&4606 length of Style 6 and 7 8,000(2,400 m) Signal 98630,Belden 9575,WPW991 loops. 40 ohms per 4,875(1,450 m) Direct Burial Cable Isotec branch maximum for Style 3,225(980 m) NP713110VNQ-S 4 loops 18 AWG(0.75 mm2):Genesis 4402&4602 Signal 98300,Belden 9574,WPW975 Connects to Direct Burial C le Isotec SLC loop Addressable NP714110VNQ-S (power-limited) Devices 12 AWG(3.25 mm2):Belden 5020UL& Twisted,unshielded pair 6020UL,Genesis WG-4315&WG-4515 40 ohms maximum per 10,000(3,000 m) 14 AWG(200 G(2,Genesis & 1G-4513 olden 51 U length of Style 6 and 7 8,000(2,400 m) 6 2 loops. 40 ohms per 4,875(1,450 m) 16 AWG(1.30 mm2):Belden 5220UL& branch maximum for Style 3,225(980 m) 6220UL,Genesis WG-4311 &WG-4511 4 loops 18 AWG(0.75 mm2):Belden 5320UL& 6320UL,Genesis WG-4306&WG-4506 Untwisted,unshielded 3,000(900 m) 12-18 AWG(3.25-0.75 mm2)using listed pair' wire N_ onnects to wisted,spiel ed pair with (EIA-485) annunciator mod- a characteristic imped 6,000(1,800 m) 18 AWG(0.75 mm2) (power-limited) ules ance of 120 ohms EIA-232 nnects to (power-limited) remote PC com- Twisted,shielded pair 50(15 m) 18 AWG(0.75 mm2)minimum puter aximum loop wire resis- MMF-300 and Initiating tance is 40 ohms for the MMF-301 Device MMF-300 and 20 ohms for 2.500(760 m) 12-18 AWG(325-0.75 mm2) Circuit (power-limited) the MMF-301 o more t an a 2.4 volt MMF-302 Initiating Device drop allowed at end of cir- 2,500(760 m) 12-18 AWG(3.25-0.75 mm2) (power-limited) Circuit cuit. s Maximum um loop ohms wire resistanceistance limitation In alarm,no more than a set by 1.2 volt 2 CMF-300 Notification Appli- maximum line 12-18 AWG 3.25-0.75 mm ) 1.2 volt drop allowed at (power-limited) ance Circuit end of circuit drop a)When using untwisted,unshielded wire,full conduit is recommended for optimum EMI/RFI protection. a.t...E.'.4F.3'vs... ;e..t%{..... ..... ,Y'.4s`P/IV, Y,S4'.'xYdiRn4:".,, 'aa•r.. > ;3Ec. - .—. DF-5241 B:A•04!05107—Page 3 of 4 SYSTEM SPECIFICATIONS (nonconden ±sing) at 32°C ± 2°C (90°F 3°F)- However, the System Capacity useful life of the system's standby batteries and the electronic Intelligent Signalling Line Circuits.......................................1.1 components may be adversely affected by extreme tempera- • Addressable device capacity 50 lure ranges and humidity. Therefore, it is recommended ecommen e that this system and its peripherals be installed in an environment• ....................20 y Programmable software zones.........................................20 with a normal room temperature of 15—27°C/60—80°F. Annunciators................................................................... 8 NFPA Standards The MS-9050UD complies with the following NFPA 72 Fire Electrical Specifications AC Power: 120 VAC,60 Hz,0.3 A. Alarm Systems requirements: Battery: Two 12 V 18 AH lead-acid batteries.Battery Charger —LOCAL (Automatic, Manual, Waterflow and Sprinkler Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of Supervisory). two 18 AH batteries.) —AUXILIARY(Automatic,Manual and Waterflow)(requires Communication Loop: Supervised and power-limited. 4XTMF). Notification Appliance Circuits: Terminal Block provides —REMOTE STATION (Automatic, Manual and Waterrouble ow) connections for two NACs,Style Y(Class B)or.Style Z(Class (Where aryAeT is not s may caccepted, the alarm, trouble ei and d A). Special Application power. Power-limited, supervised cir- supervisory For reverse ay be pconnected to g L 86rm and cuitry. Maximum signaling current per circuit: 2.5 A. End-of- trans 4XTMF is required.) Resistor:4.7 kohm,'/�watt(PIN 71252 UL listed)for Style trouble, Y (Class B) NAC. Refer to the Fire-Lite Device Compatibility —PROPRIETARY(Automatic,Manual and Waterflow). Document for listed compatible devices. —CENTRAL STATION (Automatic, Manual and Waterflow, Two Programmable Relays and One Fixed Trouble Relay: and Sprinkler Supervised)- Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive).Form-C relays,nonpower-limited,nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- 9050U0 control panel. In some cases, certain modules may Door: 19-26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x not be listed by certain approval agencies,or listing may be in 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x process.Consult factory for latest listing status. 16.65" (42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring UL:S624 (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. FM approved pp g p • CSFM:7165-0075:210 Shipping S ecifications MEA:442-06-E Weight:26.9 lbs.(12.20 kg.)Dimensions:20.00"(50.80 cm.) high x 22.5"(57.15 cm-)wide x 8.5"(21.59 cm.)deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH LiteSpeed"is a trademark;and FireLite®Alarms®and System Sensor® are registered trademarks of Honeywell International Inc.Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. 82007 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. We try to keep our product information up-to-date and accurate. This document is not intended to be used for installation ur ores. IS09001 We cannot cover all specific applications or anticipate all requirements. 30 i All specifications are subject to change without notice. t �l� Made in the U.S.A. QVAt1TY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)69911 105. www.firelite.com Page 4 of 4—DF-52418:A•04105/07 January 26, 2005 DF-52185 B-150 LCD-80� Fire LITE?�ALarms 8o-Character Liquid Crystal Display Remote Nre Annunciator www.firelite.com Section: Annunciators GENERAL l -J California State Fire The LCD-80F is a compact, cost-effective, 80-character, �� Marshal backlit LCD remote Fire Annunciator for use with the *4 7120-0075:190 Fire•Lite MS-9200UD and MS-9600 Fire Alarm Control Pan- els(FACPs).The LCD-80F displays complete system point LISTED CS635 status information and includes control switches for remote S2424 control of critical system functions. MC EA {Y� Up to 32 LCD-80Fs may be connected onto the EIA 485 terminal port (TB7)of each FACP. The LCD-80F requires 72-01-E APPROVED no programming,which saves time during system commis- sioning. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host . panel_ = Control switches for System Acknowledge, x . Signal Silence, Drill and Reset with enable v. System status LEDs for Power,Alarm,Trouble, Supervisory and Alarm Silenced. ke Ia No programming necessary LCD 80F con `°' nects to the terminal port(TB7)on the FACP_ Displays device type identifiers, individual point alarm,trouble or supervisory,zone and custom alpha labels. • Time-and-date display field. LCD-80F Aesthetically pleasing design. • May be powered by 24 VDC from the host FACP or by remote power supplies(requires 24 VDC). The LCD-80F provides the FACP with up to 32 remote se- Up to 32 LCD-80F annunciators per FACP. rially connected annunciators.All field-wiring terminations on the LCD-80F use removable, compression-type fermi- Plug-in terminal blocks for ease of installation and ser- nal blocks for ease of wiring and circuit testing. vice. Communication between the FACP and the annunciators Can be remotely located up to 6,000 feet(1828.8 m)from is accomplished over an EIA-485 serial interface, which the FACP. greatly reduces wire and installation cost over traditional Local piezo sounder with alarm and trouble resound. systems. Six wires total are required:four for the EIA-485 • Semi-flush mounts to 2.188"(5.556 cm)minimum deep, communications(two in and two return);and two for the 24 three-gang electrical box(Fire-Lite PIN 10103)or three- VDC regulated power. Dip switches control local functions gangable electrical switchbox. such as:piezo disable,control switches/key-switch disable, Surface-mounts to Fire•Lite SBB-3 surface backbox. transmitfreceive mode. OPERATION INSTALLATION The LCD-80F annunciator provides the FACP with point The LCD-80F can be semi-flush mounted to a 2.188"(5.556 annunciation with full display text on an 80-character LCD cm)minimum deep,three-gang electrical box(Fire•Lite PIN display. The LCD 80F also provides an array of LEDs to 10103) or three-gangable electrical switchboxes. Alter- indicate system status, and includes control switches for nately,an SBB-3 surface backbox is available for surface- remote control of critical system functions. mount applications. Lite®Alarms is a Honeywell company This document is not intended to be used for installation purposes We try to keep . our product information up-to-date and accurate. We cannot cover all specific R applications or anticipate all requirements. All specifications are subject to change without notice. Made,n theu.s A. For more information, contact Fire-Lite Alarms. One Fire-Lite Place. -4105ord, Q5Allii SYSTEMS Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-52185-01,26/05 - °age 1 of 2 PRODUCT LINE INFORMATION 5 556 aflg electrical box, minimum 2.188" LCD-80F 80-character,backlit,LCD Fire Annunciator with 10103 cm)deep, for semi-flush mount applica- control switches for remote control of system functions, and key-switch lock- lions. SBB-3 Three-gang surface backbox for surface-mount applications. LCD-80F TERMINAL MODE WIRING EXAMPLE Up to 6.000 ft.(1828.8 m)between EACH DEVICE in the EIA-485 loop LCD 80F LCD 80F Terminal Mode EIA-485 _ - �uOciC_ L �l 24 VDC(2-wires) ) ._ LCD-80F Up to 6,000 ft.(1828.8 m) �— — back from last device o end of EIA 485 loop ©0C2 L_j - Terminal Mode EIA-485 return Addressable (2-wires) Fire Alarm Control Panel t'Iotes: 1) EIA-485:Maximum of 6,000 feet(1828.8 m)cable length from 3) Betweed pair for dta LCD-80F annunciator un cat one and a pair for 24 1sted- VDC each to LCD-80F annunciators,6.000 ft.cable length between each LCD-80F and 6,000 ft.from the last LCD 80F back to the power.The return circuit only requires two wires(twisted) for data communication supervision,wired from the last LCD- FACP.Circuit is power-limited. 80F annunciator on the loop. 2) Up to 32 LCD-80F annunciators may be used on the EIA-485 circuit.When multiple LCD-80Fs are used,the FACP will re- quire additional power supplies(refer to panel documenta- tion). _ MOUNTING TO BACKBOX(ES) Mounting Holes(4) 5zig5mnl+ t The LCD-80F annunciators can be semi-flush mounted oun e in a three-gang electrical box with a minimum depth of 2.188" l) LCD-80F flange li (5.556 cm)(Fire'Llte PIN 10103). "" FIRE ALARM ANNUNCIATOR The LCD-80F annunciators can be mounted in three gangable electrical switchboxes connected together. C NOTE:Alternately,LCD-80F annunciators can be mounted r FIRE-LITE ALARMS, INC. to the SBB-3 surface backbox for surface-mount applica- SYSTEMS/\LL NORMAL , t 11:O6A 032001 lions. -. --- — i Electrical Installer's Note: This annunciator may not fit I 5 �1 ra„ J easily into a standard 3-gang electrical box if locking clamps are used to secure wiring entering the rear or side knock _ --- i _ outs. Only use the TOP or BOTTOM knockouts to bring -- — — wiring into a standard 3-gang electrical box. _ __L l - ——t - 5.813"(14,764 cm) wide x 4.0"(10.16 cm) Ii high x minimum 2.188" (5.556 cm) deep, III three-gang electrical box (Fire-Lite PIN 10103,shown at right). I' Gl �I c� o'.n1l9F105 July 8,2004 DF-52301 -D 025 FCPS-24FS6 FI CE'lffee ALarmS 24 volt, 6 Amp Remote Power SuPPlY t,yww.firetife.com Section: Power SupplieslAccessories California GENERA , State Fire FM �is ��Marshal The FCPS-24FS6 is a compact, cost effective: 6-amp re- \` /7315-0075:206 mote power supply with battery charger. The FCPS-24FS6 APPROVED r_'"'_`I may be connected to any 12-or 24-volt Fire Alarm!C8 Control of LISTED M EA Panel (FACP) or may stand alone. Primary applications pp S2424 include Notification Appliance (bell) Circuit (NAC) expan- 219-02-E Sion(to support ADA requirements n NAn acces- sories- synchroniza- tion) or auxiliary power to support The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con I, '� l'it figured as either four Class B(Style Y)or Class A(Style A, with ZNAC-4 option module). Alternately,the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ng up to 18 Amp Hour batteries. FEATURES UL Listed NAG Synchronization using System Sensor, n Wheelock or Gentex (Commander Series) appliances- Cascadable up to 10 power supplies(four with Gentex) with strobe timing maintained. Operates as a sync follower or a sync generator(default). See note on reverse side_ Contains two, ₹ully-isolated input/control circuits (trig- gered from FACP Notification erpermanently on [stand- alone Circuit expander mode] or jumped mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300)for alarm activation. Four ClassB(StyleY)orfourClassA(StyleZ)(wiihZNAC - AC trouble report selectable for immediate or 8 hour 4 Module) Notification Appliance Circuits- delay- 6.0 A full load output(3.0 A maximum per circuit)in NAG - Works with virtually any UL 864 fire alarm control which expander mode (UL 864). utilizes an industry-standard reverse-polarity notifica- 4.0 A continuous output in stand-alone mode(UL 1481). tion circuit (including unfiltered and unregulated bell In stand-alone mode, output power circuits may be - Requires in ut tri er voila e of 9.0 32 VDC. p g9 g configured as resettable(reset line from FACP required) _ Self-contained in compact, lockable cabinet (15" [38.1 or non-resettable or a mix of two and two. 0 cm]D Fully regulated and filtered power output (optimal for cm]H x 14.5"[36.8 cm]W x 2.75"[7. ). powering four-wire smoke detectors, annunciators and . Includes integral battery charger capable of charging up other system peripherals requiring regulated/filtered to 18 AH batteries. Cabinet capable of housing 7.0 AH power). batteries_ power-limiting technology meets UL power-limiting re- • Battery charger may be disabled via dip switch for appli quirements. cations requiring larger batteries. Form-C normally-closed trouble relay- - Fixed, clamp-type terminal blocks accommodate up to Fully supervised power supply, battery and Notification 12 AWG(3.1 mm2)wire. Appliance Circuits. Selectable earth fault detection. Ernoe larms is a Honeywell company. to keep our product Is0 9001 ent is not intended to be used for installation purposes. Wns or anticipate all up-to-date and accurate. We cannot cover all specific appeicatio � g Lure ts. All specifications are subject to changecwithout notice.Northford, Connecticut 06472 Q p (j Y S Y S j E M S formation, contact Fire-Lite Alarms 9One 05re-Cite Place, e 1 of 2 0) 627-3473, Toll-Free FAX (8 77) DF-52301 07108/04 — Page STANDARDS and CODES Example 2 the FOPS-24FS6 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and The FOPS-24FS6 complies with the following standards power options are available. NFPA 72 National Fire Alarm Code. resettable UL 864 Standard for Control Units for Fire Alarm Sys Resettable outputs are created by connecting the resettable terns (NAC expander mode). output from the FACP to one or both of the FCPS-24FS6 UL 1481 Power Supplies for Fire Alarm Systems inputs. (stand-alone mode). Example 3 SPECIFICATIONS Use addressable control modules to activate the FCPS- 24FS6 versus the FACP Notification Appliance Circuits_ This Primary(AC)Power typically allows for mounting the FOPS-24FS6 at greater FCPS-24FS6: 120 VAC 60 Hz,• -2 A maximum 600V insu- distances* away from the FACP while expanding system Wire size:minimum 14 AWG(2.0 mm ) architecture in various applications. lation. In this example, an addressable control module is used to Control in tCir uit Trigger Input Voltage: 9.0 to 32 VDC. activate the FCPS-24FS6 and an addressable monitor Module is used to sense FCPS-24FS6 trouble conditions. Trigger Current: 2.0 mA(16-32 V). Local auxiliary power output from the FCPS-24FS6 pro- (per input) 1.0 mA(9-16 v). vides power to the addressable control module. Trouble Contact Rating 5.0 A at 24 VDC. •Fire-l-ite's MS-9200, MS-9200OD, (198 point)or MS 9600{636 Auxiliary Power Output point) addressable FACPs have the capability of locating control Specific Application Power- 500 mA maximum. and monitor modules up to 10,000 feet(3048 m)away. Output Circuits +24 VDC filtered, regulated. Sync Follower/Generator Note: In some installations, it 3.0 A maximum for any one circuit. is necessary to synchronize the flash timing of all in the system for ADA compliance. Strobes• 4.0 A maximum total continuous current for all outputs strobes monitoring very short timing pulses (Stand-alone mode). accomplish this by 6.0 A maximum total short-term current for all outputs on the NAC power,which are created by a Fire • Alarm (NAC Expander mode). Control Panel such as the Fire•Lite MS-9600. When Secondary Power(Battery)Charging Circuit installed at the end of a MS-9600 NAC wire run,this FloatC s lead-acid batteries only. power supply can track(i.e. "follow")the strobe synchro- - Float Charge Voltage: 27.6VDC. nization timing pulses on the existing NAC wire run. This Maximum Charge Current: 1.5 A. maintains the overall system flash timing of the addi- Maximum Battery Capacity: 18 AH. tional strobes attached to this power supply- When this power supply is configured (via DIP switch settings) as a "sync follower,"this supply's NAC outputs ORDERING INFORMATION present at this Iv (120 track the strobe synchronization pulsesare originated FCPS-24FS6 Remote charger power supply supply's sync input terminal. The pulses VAC). Includes main printed circuit board, transformers, red enclosure, and from an upstream FACP or other power supply. When this power supply is configured (via DIP switch installation instructions. settings) as a"sync generator," this supply's sync input FCPS-2456RB Replacement mother board. terminal are not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In"sync generator" mode, PM 90286 FCPS-24F Module Mounting Kit Sensor,Wheelock,or Gentex)is ZNAC-4 Class A(Style Z)NAC option module the sync type(System ay selectable via DIP switch settings. A77 7166 1m2onto/24 VDC end-of-line monitoring 4-wire smoke detector power- BAT-1270 Battery,12 volt,7-0 AH(two required). APPLICATIONS Example I Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B(Style Y)outputs or 4 Class A (Style Z)outputs(using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 — DF-52301 07108/04 DF-52149 E-150 May 3,2001 SD350�A�/SD350To� fire icr Alarm S Addressable Photoelectn Section: Addressable Devices www.firelife-corn GENERAL low-profile plug-in The SD350 and SD350T Addressable, °F°RL„e°9 Photoelectric Detectors use astate-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's MS-9200 E"vlriE�Pps and MS-9600 Addressable Fire Alarm Control Panels. The M SERvtc� SD350T adds thermal sensors that will alarm at a fixed tem- perature of 135°F. Since this detector is addressable,it will 7272 0075194 help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (Part No. RA400Z). FEATURES . SLC Loop 2-wire loop connection. Unit uses base for wiring. Addressingr jI • Addressable by device. - Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) entry of address Architecture Unique single source, dual chamber design to respond SD350 quickly and dependably to a broad range of fires. Other System Features Sleek,low-profile design. . Integral communications and built-in type identification. - Fullyocoated circuit boards and superior RF/transient pro-• tectn. Built-in tamper-resistant feature. . 94-VO plastic flammability rating. Removable cover and insect-resistant screen for simple - Low standby current. field cleaning Options Operation . Withstands air velocities up to 1,500 feet-per-minute with- • Remote LED output connection(Part No. RA400 ). APPLICATIONS out triggering a false alarm. Use photoelectric detectors in life-safety applications to pro * Factory preset at 1.5%nominal sensitivity for panel alarm threshhold level. vide a broad range of fire-sensing capability,especially where * Visible LED"blinks'when the unit is addressed(commune- smoldering fires are photoelectricdet Ioc i satatiose sing fasar e am- of- ten better than p caiing with the fire panel)and latches on in alarm. trig fires. Mechanicals • Sealed against back pressure CONSTRUCTION a in an off-white Direct surface mounting or electrical box mounting. These detectors are constructed smoke o detectors are Mounts to: single-gang box, 3.5" or 4" octagonal box, or color.The SD350(T)plug-in low-profile 4"square electrical box(using a plaster ring-included), designed to commercial standards and offer an attractive ap- pearance. This document is not intended to be used for installation purposes. Doves allVe try speci to keep aPPii— ��O 9001 product information up to-date and accurate- without �--- lions or anticipate all requirements. All specifications are subject to change r�----- notice. For more information,contact Fire•Lite Alarms,one Fire-Cite Place,N0rthfofd, Made in the U.S.A. Connecticut 06472. Phone: (800)627-3473, Toll Free FAX: (877)699-4105, FAX �I� '6Mf#C11� Back:888 388-3299. DF-52149— Page 1 012 INSTALLATION PRODUCT LINE INFORMATION The SD350(T) Plug-In Detectors use a detatchable mount- SO350(A) Addressable Photoelectric Detector(B350LP my base to simplify installation, service and maintenance. base included). (A) model has ULC listing. Mount base on box which is at least 1.5 inches (3.81 cm) SD350T(A) Same as above with thermal element (B350LP base included).(A)model has ULC deep. Suitable boxes include: listing. 4"(10.16 cm)square box with plaster ring. RA40OZ Remote LED.Mounts to a single-gang box. 4"(10 16 cm)octagonal box- B350LP Plug-in detector base (included).Diameter. 6.1"(155mm).Mounting:4"(102mm)square 3.5"(8.89 cm)octagonal box. box with or without plastic ring, 4"octagon box,3 1/2"octagon box or single gang box. Single-gang box All mounting boxes have a minimum depth of NOTE:Because of the inherent supervision provided by the 1.5"(38 mm). SLC loop, end-of-line resistors are not required. Wiring"T- B224RB Plug-in System Sensor relay detector base taps"or branches are permitted for Style 4(Class B)wiring. Diameter:6.2"(157 mm). Mounting:4"(102 mm)square box with or without plastic ring, OPERATION 4" octagon box, 3 1/2" octagon box. All Each SD350(T) uses one of 99 possible addresses on the mounting boxes have a minimum depth of MS-9200 Signaling Line Circuit(SLC) or up to 318 (159 on 1.5"(38 mm). each loop)on the MS-9600 SLC.It responds to regular polls B501 911 Plug-in System Sensor sounder detector from the system and reports its type and status. base.Diameter:6.0"(153mm).Mounting:4' (102 mm)square box with or without plastic The SD350(T) Addressable Photoelectric SensrTM unique ring. Mounting box has a minimum depth of unipolar chamber responds quickly and uniformlyto a broad range of smoke conditions and can withstand wind gusts up 1.5"(38 mm). to 1,500 feet-per-minute without sending an alarm level sig- nal.Because of the unipolar chamber,the SD350(T) is ap- proximately two times more responsive than most photoelec- tric sensors.This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested(required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to an MS-9200 or MS- 9600 addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS 9200 and MS- 9600 for record keeping. SPECIFICATIONS voltage range: 15-32 VDC(peak). Standby current:300 pA @ 24 VDC. LED current:6.5 mA @ 24 VDC (latched"ON"). Air velocity: 1,500 ft./min. (7.6 m/sec.)maximum. Diameter:5.0 inches(12.7 cm),6.2 inches(155 mm)installed in B35OLP Base. Height: 1.7 inches(43 mm)installed in B35OLP Base. Weight:3.6 oz- (102 g). Operating Temperature Range:0°to 49°C (32°to 120°F) SD350. Operating Temperature Range:0"to 38° C (32°to 100°F) SD350T. Temperature:0°-49°C (32° - 120°F). Relative humidity; 10%-93%, non- condensing. 7 — nF-52149 June 25, 2001 DF-52167 E-700 H350/H350R LI-1�-�W /�LarmS Intelligent Addressable Thermal (Heat) �r �"* Detectors for use with MS-9600 Section: Addressable Devices wtvim iretite.com GENERAL (' j ULC 4Gs<<" ��,�-0t„�:I�5 The H350 and H350R model thermal detectors are address ;g "••,; able sensors that use a state-of-the-art thermistor sensing circuit for fast response-These sensors are designed to pro- ^•EMp SERVWE vide open area protection and are intended for use with the MS-9600 tire alarm control panel. Both the H350 and H350R sensors provide fixed tempera- ture alarm detection at 135°F. The H350R sensor responds to rate-of-rise conditions of greater than 15°F/minute. Two LED's on each sensor light to provide a local, visible sensor indication.Remote LED annunciator capability is avail- able as an optional accessory (Part No. RA400Z) FEATURES SLC Loop Two-wire SLC loop connection- Addressing - Addressable by device. of address. H350 - Direct Decade 01-159(MS 9600)entry Architecture Sleek,low-profile,stylish design-State-of-the-art thermistor technology for fast repsonse. • Integral communications and built-in device-type identifica- APPLICATIONS lion. Built-in tamper resistant feature. Use thermal detectors for protection of property. Built-in functional test switch activated by external magnet. CONSTRUCTION Operation These detectors are constructed of Bayblend©in an off-white • Factory preset at 135°F(58°C)- er minute. color. - Rate-of-Rise model(H350R), 15°F(8.3°C)p • 360°-field viewing angle of the visual alarm indicators(two The H350 and H350R plug-In intelligent thermal detectors 9 bicolor LEDs). LEDs blink green in Normal condition and are designed to commercial standards and offer an attrac turn on steady red in Alarm. tive appearance. • Visible LEDs"blink"every time the unit is addressed. INSTALLATION itAecaled against back pressure. SEMS screws for wiring of the separate base. use a detachable base to simplify installation, service and • Designed for direct-surface or electrical-box mounting. maintenance. Installation instructions are shipped with each • • Plugs into separate base for ease of installation and main- Mount base(all base types)on box that is at least 1 5"(38.1 tenance. • Separate base allows interchange of photoelectric,ioniza- mm)deep. Suitable boxes include: lion and thermal sensors. • 4"(101.6 mm)square box. Other System Features Remote test feature from the panel- • 3 1/2"(88.9 mm)or 4"(101.6 mm)octagonal box. • • walk test with address display. Single-gang box(except relay or isolator base). Low standby current. * 94-5V plastic flammability rating. NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required- wiring Options Remote LED output connection to optional RA400Z remote ty'or branches are permitted for Style 4(Class"B")wiring LED annunciator. only • Recessed(RMK400)or surface(SMK400)base mounting kits. Bayblend®is a registered trademark of Bayer Corporation. our IS0 9901 Edocumentent is not intended to be used for installation purposes. Wepry to keep I cannot cover rmation up-to-date and accurate. we all s ecific ica-icipate all requirements. All Specifications are subject to chap Northford,more information,contact Fire•Lite Alarms,One Fire-Lite Place,4105, FAX &MAIDMade in the U.S.A. t 06472. Phone- (800) 627-3473. Toll Free FAX: (877)699388-3299. pF-52167 — Page 1 of 2 OPERATION Each H350 or H350R uses one of 159 possible addresses (MS-9600)on a control panel SLC loop.It responds to regu- lar polls from the control panel and reports its type and the status- If it receives a test command from the panel (or a local magnet test),it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel.The H350 and H350R offer features and performance that represent the latest in ther- mal detector technology. SPECIFICATIONS Diameter: 6.1"(155 mm) installed in B350LP. Height: 2.0" (51 mm). Weight: 5 oz. (150 gm). installation temperature: -4°to 100° F(-20°to 38°C). Humidity range:10%to 93%relative humidity(non-condens- ing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B35OLP flanged base. Fixed Temperature setpoint: 135° F (57°C). Rate of Rise detection:Responds to greater than 15°F/mm . PRODUCT LINE INFORMATION H350 Intelligent thermal sensor(B35OLP base in- cluded). H350R Same as above with Rate-of-Rise feature. RA400Z Remote LED. Mounts to a single-gang box. B35OLP Plug-in detector base(included).Dimensions: 6.1"(155 mm. Mounting:4"(102 mm)square box with or without plastic ring,4"octagon box, 3 1/2" octagon box or single gang box. All mounting boxes have a minimum depth of 1.5" (38 mm). M02-04-00 Test magnet. B224RB Plug-in System Sensor relay detector base. Diameter:6.2"(157 mm). Mounting: 4"(102 mm)square box with or without plastic ring,4"octagon box,3 1/2"octagon box.All mounting boxes have a minimum depth of 1.5"(38 mm). BS01BH Plug-in System Sensor sounder detector base. Diameter:6.0"(153 mm)_ Mounting: 4"(102 mm)square box with or without plastic ring. Mounting box has a minimum depth of 1.5"(38 mm). Pace 2 of 2 - DF-52167 May 2,2001 DF-52176 E-600 D350P/D35ORP Fi re UTe®ALarms Intelligent Addressable Photoelectronic Duct Smoke Detector Section: Addressable Devices D www.firelite.corn (GENERAL TI The new D350P and D350RP addressable photoelectric duct ^�r.;o F M smoke detectors are used exclusively with the Fire•Lite MS L wf; 9200 and MS 9600 addressable fire alarm control panels. Since 'these duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early 3240-0075189 stages, potentially saving precious rescue time while also reducing property damage.The D350RP offers the same fea- =tures as the 0350P while adding a Form-C relay. An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct sys- tem is thus distributed to the entire building. Smoke deter �a f.6lil i: tors for use in air duct systems sense the presence of smoke in the duct. .' The D350P and D350RP air duct smoke detectors are ph - toelectric detectors,combining this detection technology with an efficient housing design that samples air passing through O350Pthe duct,allowing detection of a developing hazardous con- dition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector.With the D350RP,appropriate action can be taken to shut off fans and blowers and to change over air handling systems, etc. This can isolate toxic smoke and tire gases or prevent their distribution thoughout areas served by the duct system. control panel specifications for wiring requirements before wiring the detector loop.The D350P/D350RP detector is de- Two LED's on each detector light to provide a local,visible alarm indication. A remote alarm output is provided for use signed for ease of wiring; the housing provides a terminal with auxiliary devices.The D350P and D350RP have remote strip with clamping plates. test capability with the RTS451/RTS451KEY Remote Test Remote LED annunciator capability is available as an Station,as well as remote communication using the RA400Z op- tion.Each duct smoke detector can only be wired to one re- alarm LED. mote accessory. APPLICATIONS SPECIFICATIONS Duct smoke detectors have the following limitations:- D350P NOT a substitute for open area smoke detectors. Operating voltage range: 15 to 32 VDC. - NOT a substitute for early warning detection. NOT a replacement for a building's regular fire detection Scary 5 seconds with LED blink enable b 00 one communication system. Operating temperature range:32°to 131°F(0°to 55°C). Call your Fire•Lite distributor for a copy of System Sensor's Humidity range:10%to 93%(non-condensing). application guide, Proper Use of Smoke Detectors in Duct Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 Applications(A05-1004-00). meters/min.). INSTALLATION Dimensions- 14.375" (365.125 mm)wide x 5.500" (13.970 Wiring: For signal wiring (the wiring between detectors or mm)high x 2.750"(69.850 mm)deep. from detectors to auxiliary devices), it is recommended that single conductor wire be no smaller than 18 AWG(0.75 nri Options: RTS451, RTS451 KEY, RA400Z. Separate auxil- ry power not required The duct smoke detector terminals accomodate wire sizes up to 12AWG(3.25 mm2). Flexible conduit is recommended D35ORP for the last foot(30.48 cm)of conduit:solid conduit connec Opting voltage range: 15 to 32 ag)and 24 VACNDC or 120/240 VAC auxiliary power(sepa- C (Comm. line volt- tions may be used if desired Smoke detectors and alarm system control panels have sped- rate source). NOTE: The D350RP requires a separate aux- fications for Signaling Line Circuit(SLC)wiring. Consult the diary source. This document is not intended to be used for installation purposes. We try to]keepourproduct information up-to-date and accurate. We cannot cover all specifictions or anticipate all requirements. All specifications are subject to changnotice For more information,contact Fire-Lite Alarms,One Fire-Lite Place,Connecticut 06472. Phone: (800) 627-3473, Toil Free FAX: (877)699-4 FNcITI Back:888 388-3299. DF-52176— Page I of 2 Standby current: 300 pA @ 24 VDC (one communication PRODUCT LINE INFORMATION Addressable duct detector housing with every 5 seconds with LED blink enabled). hotolectric smoke detector. Auxiliary power current draw(@ 24 VDC):26 mA(standby), D350RP Addressable duct detector housing with 87 mA (alarm). photolectricsmokedetectorand DPDT relay. Operating temperature range:32°to 13i°F(0°to 55°C) duct widths 1'toD 2'(see Tumidity range:10%to 93%(non ST-1-5 Metal sampling t e d-condensing). table at left for metric lengths). Duct air velocity: 500 to 4,000 feetlmin. (152.4 to 1219ST-3 Metal sampling tupe,duct widths 2'to 4'. 1219.2 Metal sampling tupe,duct widths 4'to 8'. meters/min.). ST-5 ST-10 Metal sampling tupe,duct widths 8'to 12' Dimensions= 14.375"0"(69(365.1250mm) wide x 5.500"(13.970 Remote annunciator alarm LED. mm)high x 2.750"(69.850 mm)deep. RA400Z RTS451 Remote test station. Mounts in single-gang Options: RTS451,RTS451KEY, RA400Z_APA451. box. Includes red alarm LED and magnet Relay contact ratings:2 Form-C,DPDT,10 A @ 250 VAC, test switch. 10 A © 30 VDC (resistive). Minimum switching current of activated remote test station. 100 mA @ 5 VDC. RTS451KEY Key F36-09-00 Replacement filters. INLET TUBE SELECTION M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. *(2-4384 e Duct Width Inlet Tube` P48-55-00 Replacement end cap for plastic sampling tube_ P48-21-00 Replacement end cap for metal sampling .6096 m) ST-1.5 tube. A5053FS Replacement photoelectric sensor board. 6096 to 1.2192 m) ST-3 A5067 Replacement power board(without relay)- A5060 Replacement power board(with relay). .2192 To 2 4384 m) ST-5 2.4384 to 3.6576 m) ST- 00 __j "NOTE: Inlet tube is required and must be purchased separately.Order one inlet tube for each duct smoke detec- tor ordered. — nF-52176 July 14,2004 DF-52004 F-050 rm�* gG_12 Series FireLuTC® ALa 1 A Manual Fire Alarm Pull stations www,firelite.com Section: Conventional Initiating Devices C,. California GENERA. -" State Fire ll' `: 1, The Fire-Lite Alarms BG-12 Series is a cost-effective,tea- At Marshal :``-';' 7150 0075:184 �.�. US Lure-packed, non-coded series of manual fire alarm stations. It was designed to meet multiple applications LISTED with the installer and end-user in mind. The BG-12 Series features a variety of models including single- and dual- action versions. f 1V1 The BG-12 Series provides Fire-Lite Fire Alarm Control 67-02-E Panels(FACPs),as well as other manufacturers'controls, with a manual alarm initiating input signal. Its innovative AQPRQV� design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38,Standard for Manually Actuated Signaling Boxes. Easily operated(single-or dual-action),yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. - The word"ACTIVATED"appears on the top of the handle in bright yellow, further indicating operation of the sta- tion_ Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. �? Braille text included in finger-hold area of operation handle and across top of handle Multiple hex- and key-lock models available. U_S patent-pending hex-lock needs only a quarter-turn Terminal numbers are molded into the backplate,elimi- to lock/unlock. nating the need for labels_ Station can be opened for inspection and maintenance Switch contacts are normally open without initiating an alarm. Can be surface (with SB-1/0 or SB-10) or semi-flush Product ID label viewable by simply opening the cover', label is made of a durable long-life material. mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm)square electrical box. The words "NORMAL" and "ACTIVATED" are molded Backplate is large enough to overlap a single-gang into the plastic adjacent to the alarm switch (located in- backbox cutout by up to 1/2" (12.7 mm). side). optional trim ring (BG-TR). Four position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- Spanish version (FUEGO) available (BG 12LSP).the Fire-Lite tive 8/32 screws for easy connection to Initiating Device Desiged to Models pa k gereplad in attractive,Lclearyplasticc (PVC), BG-10 Series Circuit (IDC). I Point of-Purchase packages. Packag- Terminal screws backed-out at factory and shipped ready clamshell-stye, to accept field wiring (up to 12 AWG/3.25 mm2). ing includes a cutaway dustipaint cover in shape of pull station. Fire^rite© Alarms is a Honeywell company. ' � ��0� This document is not intended to be used for installation purposes.we fry to keep our product information up-to-date and accurate. we cannoi cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Northford, Q Y l Il T T SYSTEMS For more information, contact Fire-Lite Alarms, One Fire-Cite Place, Connecticut 06472. Phone: (800) 627-3473. Toll-Free FAX: (877) 69911105. pF-52004 07114!04 Page 1 of 2 CONSTRUCTION ties Act(ADA)or per nationalllocal requirements. Manual Cover, backplate and operation handle are all molded Stations shall be Underwriters Laboratories listed. of durable polycarbonate material. *NOTE: The words"FIRE/FUEGO"on the 13G-12LSP shall ap- pear on the front of the station in white letters.approximately 3/ Cover features white lettering and trim. 4"high. Red color matches System Sensor's popular PRODUCT LINE INFORMATION SpectrAlert'"" horn/strobe series Model Description OPERATION The BG-12 manual pull stations provide a textured finger- BG-12S Single-action pull station with pigtail connec- hold area that includes Braille text. In addition to PUSH tions,hex lock. IN and PULL DOWN text,there are arrows indicating how BG-12SL Same as BC-12S with key lock. to operate the station, provided for non-English-speaking BG 12 Dual-action pull station with SPST N/O persons switch,screw terminal connections,hex lock. Pushing in and then pulling down on the handle activates the normally-open alarm switch_ Once latched in the down BG-12L Same as BG 12 with key lock. position, the word "ACTIVATED" appears at the top in B0,_12LSP Same as BG-12L with English/Spanish bright yellow, with a portion of the handle protruding at (FIRE/FUEGO) labeling. the bottom as a visible flag. Resetting the station is simple_ inser t the key or hex (model dependent), twist one quar- BG-12LOB Same as BG-12L with "outdoor use listing. Includes outdoor listed backbox, and seal- ter-turn: then open the station's front cover, causing the trig gasket. spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal BG-12LO Same as BG-12L with "outdoor use" listing. (non-alarm) position manually(by hand)or by closing the Does not include backbox. station's front cover,which automatically resets the switch. BG 12LA Same as BG-12L with auxiliary contacts. SPECIFICATIONS BG-12LPS Same as BG-12L with presignal feature. physical Specifications- BG-12LPSP Same me as B O) la PS g. with English/Spanish(FISB-U0 Indoor/outdoor backbox. 00100050110 00-00 00-40 0 0-+0 0 00 SB-10 Indoor use backbox. i.zs m�07u pampa �� n4 mama mnlm X WP-10 Outdoor use backbox. 4.23m) 0 a 9 m) 5.24( 5 24 00 1 0,9 00 1 Outdoor use backbox. 4 . l 4M00 4.222 CM111 4.171 WO 4.69 mama 4.)5 ota000 0066 0mm: 0 ,00) (!0.7200) (io4._700) (i'1Q)00) no79m) 17003 Key lock. i a;,gUlno ;.;,5 m0m0 2.0 m0m0 .75 m0m0 17007 Hex lock. 000(D: x,300) ('.66aJ) (3.4900) 15.08,00) 1'1.445051 ,20fl' Ibi 1.390" (35.306) Elect(rical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 3O VAC or VDC. 1 ' T Wire Length Strip Gauge ENGINEERS' & ARCHITECTS" SPECIFICATIONS I Manual Fire Alarm Stations shall be non-code,with a key- 1 000" or hex-operated reset lock in order that they may be tested, , (25.40) and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually defected as activated. Manual stations shall be constructed of red colored LE (or 0.750" polycarbonate equivalent)with clearly visible operating in- (19.05) 5,00" structions provided on the cover. The word FIRE shall ap- (139.70) pear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.' Stations shall be suitable for sur-mounting on a standard single-gang, double-gang, or 4" (mm) face mounting on matching backbox SB-10; or semi-flush (10-16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- Pane 7 of 2 — OF-52004•07/14/04 July 14,2004 DF-52121 -E-325 MMF-300(4) Series/MDF-300 Fire-LITe Aiarrr� Addressable Monitor Modules www.firelife.corn Section. Addressable Devices GENERAL ;Q; California s.-f \ Four different monitor modules are available for Fire Lite State Fire Marshal 7300-0075:185 Alarm's MS 9200, MS 9200OD and MS 9600 intelligent fire ((- )t alarm control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry contact input devices, such as conventional heat detectors and pull q. APPROVED stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). LISTED MMF-300 (Replaces M300)—The MMF-300 Moni-for Module is a standard-sized module(typically mounts to a CSXXXX 4" (101.6 mm]square box)that supervises either a Class A (Style D) or Class B(Style B)circuit of dry-contact input de- DUAL nm u vices. MMF-3O1 (Replaces M301)—The MMF 301 is a Min- iature Monitor Module (a mere 1.3" (33.02 mm) H x 2.75" (69.85 mm) W x 0.5" (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to be mounted in a single-gang box behind the device it is monitoring. - � x MMF-302 (Replaces M302) —The MMF-302 Inter- face Module is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A(Style D) or Class B (Style B) circuit. MDF-300 (New)—The MDF-300 Dual Monitor Module t,r is a standard-sized module (typically mounts to a 4" [101.6 mm] square box)that supervises two Class 8 (Style B) cir- cuits a1; of dry-contact input devices. MMF-300 MONITOR MODULE MDF-300 Built-in type identification automatically identifies this de- Device Circuit. A 47K ohm End-of-Line Resistor (provided) vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional terminates the Style B circuit. No resistor is required for power required supervision of the Style D circuit. Maximum IDC resistance High noise (EMF/RFI)immunity- is 1,500 ohms. SEMS screws with clamping plates for ease of wiring. MMF-300 Operation — Each MMF-300 uses one at Direct Decade 01 — 99 (MS-9200 and MS-9200OD) and 99 (MS-9200 and module addresses o s 0n an e 0UD SLC loop Mil S-e6 0)navail- fo 01-159 (MS-9600) entry of address. ts LED flashes red during normal operation and latches regular the Status from (open the contrllshort)eof i ands itDevis on steady to indicate alarm. and- Circuit (IDC). A flashing LED indicates that the module is The MMF-300 Monitor Module is intended for use in intel in communication with the control panel The LED latches ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches steady on alarm (subject to current limitations on the loop). . MMF-300 SpeeilFicatians it. provides either a two wire or four-wire Class A or Class Nominal operating voltage: 1.5 to 32 VDC. B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. The MMF- Maximum current draw= 5.1 mA (LED on). 300 can be used to replace M300 modules in existing sys Average operating current 400 pA (LED flashing). terns. MMF-300 Applications— Use to monitor a zone of E0L resistance: 47K o ms. four-wire smoke detectors, manual fire alarm pull stations, Temperature range: 32'F to 120'F (0'C to 49°C). waterflow devices, or other normally-open dry-contact alarm Humidity range: 10% to 93% noncondensing. activation devices. May also be used to monitor normally- 114.3 mm) high x 4" (101.6 mm)wide x open supervisory devices with special supervisory indica- Dlmens1 75 mm) deep. Mounts to a 4" (101.6 mm)square tion at the control panel. Monitored circuit may be wired as 125" an NFPA Style B (Class B) or Style D (Class D) Initiating x 2.125" (53.975 mm) deep box. Fire Lite® Alarms is a Honeywell company. to keep our product Isom 001 This document is not intended to be used for installation purposes. W applications or anticipate rnformation up-to-date and accurate. We cannot cover all specific app H�IIiFEIOII�iM I� requirements. All specifications arc subject So change without notice. Q A A L I T X SYSTEMS For more information, contact Fire-Lite Alarms. One Fire-Cite Place, Northford, Connecticut 06472. Phone: (800) 627-3413, Toll-Free FAX. (877) 699-4105- DF-52121 07/14!04 — Pa9e 1 o`3 MME-302 INTERFACE MODULE MMF-301 MINI MONITOR MODULE M compatible two-wire smoke detectors. Built-in type identification automatically identifies this - Supports device as a monitor module to the MS-9200, MS- - Supervises Dtt being and connection of external power 92000D or MS-9600. Powered directly by two-wire SLC Loop. No additional - High noise (EMFIRFI) immunity. power required. - SEMS screws with clamping plates for ease of wiring High noise (EMFlRFI) immunity. Direct-dial entry of address (01-99 for MS-9200(MS- - Tinned stripped leads for ease of wiring. 9200OD. 01-159 for MS-9600). Direct-dial entry of address (01-99 for MS 9200/MS LED flashes during normal operation LED latches steady to indicate alarm on command from 9200U0, 01-159 for MS-9600). The MMF-301 Mini Monitor Module can be installed in a control panel. single-gang junction directly behind the monitored unit. Its The MMF 302 Interface Module is intended for use in intel- small size and light weight allow it to be installed without ligent, addressable systems, where the individual address rigid mounting. The MMF-301 is intended for use in intelli- of each module is selected using built-in rotary switches. gent, two-wire systems where the individual address of This module allows intelligent panels to interface and moni- each module is selected using rotary switches it provides tor two-wire conventional smoke detectors. It transmits the a wo wire initiating device circuit for normally-open-con- status(normal, open, or alarm) of one full zone of conven- tact fire alarm and security devices. The MMF-301 can be tional detectors back to the control panel All two wire de- used to replace M301 module in existing systems. tectors being monitored must be UL compatible with the ? module. 115 0 ; I ADDRESS.._ Q 1 MMF-302 Applications—Use the MMF-302 to moni- ;3 \2 II for a zone of two-wire smoke detectors. The monitored cir- ? 3 ,"'` '3 cuit may be wired as an NFPA Style B (Class B) or Style D 1 , LOOP 1,%, )i;4 (Class A) Initiating Device Circuit.A 3.9 K ohm End-of-Line 10 5 �. I 9 g 5 Resistor (provided) terminates the end of the Style B or D 9 5 J 8 (class B or A) circuit (maximum IDC loop resistance is 25 I TENS ONES I -_ ohms). Install ELR across terminals 8 and 9 for Style C i'____ application. I-I MMF-302 Operation Each MMF-302 uses one of 159 available module addresses on a MS-9600 SLC loop It uses one of 99 on a MS-9200 or MS-9200OD. It responds H ; to regular polls from the control panel and reports its type i 1 and the status (open/normal/Short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is ! in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302 Specifications Nominal operating voltage: 15 to 32 VDC. MMF-301 Applications — Use to monitor a single Maximum current draw: 5.1 mA (LED on). device or a zone of four-wire smoke detectors, manual fire Average operating current: 270 pA (LED flashing). alarm pull stations,waterflow devices,or other normally-open EOL resistance: 3.9K ohms. dry-contact devices. May also be used to monitor normally- I voltage (between Terminals T3 and T4) open supervisory devices with special supervisory indica- External supply tion at the control panel. Monitored circuit/device is wired DC voltage: 18 to 28 volts power limited. Ripple voltage: as an NFPA Style B(Class B)Initiating Device Circuit.A 47K 0.1 VRMS maximum. Current:90 mA per module maximum. ohm End-of-Line Resistor (provided)terminates the circuit. Requires regulated, resettable 24 VDC power. MMF-301 Operation — Each MMF-301 uses one of Temperature range: 32°F to 120°F (0°C to 49°C) 159 available module addresses on an SLC loop MS- Humidity range: 10% to 93% noncondensing. 9600. It uses one of 99 on a MS-9200 or MS-9200OD. It Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm)wide x p 1.25" (31 75 mm) deep. Mounts to a 4" (101.6 mm)square responds to regular polls from the control panel and re- ports its type and the status (open/normal/short) of its Ini- x 2.125" (53.975 mm) deep box. taring Device Circuit (IDC). MMF-301 Specifications MDF-300 DUAL MONITOR MODULE Nominal operating voltage: 15 to 32 VDC. Built-in type identification automatically identifies this de- Average operating current, 375 pA maximum. vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No a i- EOL resistance- 47K ohms. tional power required. -temperature range: 32°F to 120°F (0°C to 49°C). - High noise (EMFIRFI) immunity. Humidity range: 10% to 93% noncondensing. - SEMS screws with clamping plates for ease of wiring. Dimensions: 1.3"(33.02 mm)high x 2.75"(69.85 mm)wide - Direct-dial entry of address (01 — 159 on the MS-9600, x 0 5" (12.70 mm) deep. 01-99 for MS-9200/MS-9200OD). Wire length: 6" (152.4 mm) minimum. - LED flashes red during normal operation and latches on steady red to indicate alarm. Page 2 of 3 — OF-52121 -07/14/04 The MDF-300 Dual Monitor Module is intended for use in ordinances and regulations. nteiligeni, two-wire systems, where the individual address ARCHITECTS /ENGINEERS' of each module is selected using the built-in rotary SPECIFICATIONS switches. it provides two independant two-wire fault-toter- -Lite Alarms products ant Initiating Device Circuits (IDCs) at two separate, con Specifications of these and all Fire Lite addresses. It is capable of monitoring normally are available from Fire-Lite Alarms. open-Contact fire alarm and supervisory devices, or either PRODUCT LINE INFORMATION normally open or normally closed devices for non-tire ap plicall ns. MMF-300 Monitor Module. MDF-300 Applications - Use to monitor a zone of MMF-300(A) Monitor Module (Canada). four-wire smoke detectors, manual fire alarm pull sta- MMF-301 Mini Monitor Module_ dons, waterflow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor MMF-301(A) Mini Monitor Module (Canada). MMF-302 Two Wire Detector Monitor Module normally-open supervisory devices with special supervi- sory indication at the control panel- Monitored circuit may MMF-302(A) Two-Wire Detector Monitor Module (Canada). be wired as an NFPA Style B (Class B) Initiating Device MDF-300 Dual Monitor Module. Circuit. The 47K ohm End-of-Line Resistors (provided) SMB500 Optional Surface-Mount Backbox. terminate the Style B circuii. Maximum IDC resistance is 1.500 ohms. MIDF-300 operation -Each MDF-300 uses two of 99 MOUNTING DIAGRAM (UTS-9200 or MS-92o0UD) or 159 (MS-9600) available �d modules module addresses on an SLC loop, it responds to regular for Shlfldalird-siz polls from the control panel and reports its type and the status (openlnormallshort) of its Initiating Device Circuit (IDC)- A flashing LED indicates that the module is in com- munication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). G_ MDF-300 Specifications I Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA(LED on). II I Average operating current: 750 pA(LED flashing). EOL resistance: 47K ohms. 7J Maximum IDC wire resistance: 1.500 Ohms- Temperature range: 32°F to 120°F (0"C to 49°C). ��. // Humidity range: 10%to 93% noncondensing. Dimensions: 4.5"(114.3 mm)high x 4"(101.6 mm)wide x 1 25' (31.75 mm)deep. Mounts to a 4"(101.6 mm)square ' i ry__ x 2-125" (53.975 mm) deep box. 71 Accessories: SMB500 electrical box. INSTALLATION ` C PJtF-300 MMF-302 and MDF 300 modules mount di- rectly t0 a standard 4" (101 6 mm) square, 2.125" (53.975 - mm) deep. electrical box They may also be mounted to the SMB500 surface mount box. Mounting hardware and I installation instructions are provided with each module. All wiring must conform to applicable local codes, ordi- nances, and regulations. These modules are intended for / The MMF-301 module is intended to be wired and ' " power-limited wiring only. / �� �.j �� mounted without rigid connections inside a standard elec �� % y, trical box.All wiring must conform to applicable local codes, ( i OF-52121-07/14/04 — Page 31 3 September 28,2001 DF-52'30 E-350 CMF and CRF Series ���, .L�-�, 0 Alarms Addressable Control and Relay Modules www.ffrelite.COm Section: Addressable Devices GENERAL TI F M CMFr300 Control Module (Replaces C304) u� �5 Approved The CMF-300 Addressable Control Module provides ;'•V MS 9200 and MS-9600 intelligent control ::p,= , ir. Lite Alarm's .a. panels a supervised Class B (Style Y) or Class A (Style Z) SEavic� circuit for Notification Appliances (horns, strobes, etc). z30a0075185 Addressabiiity allows the CMF to be activated,either manu- aliy or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 CON 1 ROL configured as a relay) The CRF-300 Addressable Relay Module provides the MS-9200 and MS-9600 systems with two isolated sets of Form-C dry-contact outputs for activating a variety of auxil- iary devices, such as tans. dampers, door holders, con- a� trot equipment, etc. Addressabiiity allows the dry contact to be activated, either manually or through panel program ruing, on a select basis. FEATURES 'k . Built-in type identification automatically identifies these devices to the control panel- Internal circuitry and relay powered directly by two wire SLC loop. The CMF module requires power (for horns, LL strobes,etc.). , Integral LED "blinks" green each 'time a communication . is received from the control panel and turns on in steady CMF-300 and CRF-300 Module red when activated. High noise immunity (EMF/RFI). The CMF may be used to switch 24-volt NAC power. OPERATION Wide viewing angle of LED. Each CMF or CRF uses one of 99(MS-9200)or 159 1 Me_ SEMS screws with clamping plates for wiring ease. 9600) possible module addresses on a SLC loop. Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) sponds to regular polls from the control panel and reports entry of address. its type and status, including the open/normal/short sta- tus of its Notification Appliance Circuit (NAC). The LED APPLICATIONS blinks with each poll received. On command, it activates The CMF is used to switch 24 VDC audible/visual power. its internal relay. The CMF supervises Class B(Style Y)or The CRF may be programmed to operate dry contacts for Class A (Style Z) notification or control circuits. door holders, Air Handling Unit shutdown, etc. Upon code command from the panel, the CMF will discon- CONSTRUCTION nect the supervision and connect the external power sup- ply in the proper polarity across the load device The dis- - The face plate is made of off-white Mart/I®. connection of the supervision provides a positive indica- Controls include two rotary switches for direct-dial entry tion to the panel that the control relay actually turned ON. of address (01-99 on the MS 9200 and 01-159 on the The external power supply is always relay isolated from MS 9600). the communication loop so that a trouble condition on the The CMF is configured for a single Class B (Style Y) or external power supply will never interfere with the rest of Class A (Style Z) Notification Appliance Circuit. the system. The CRF provides two Form-C dry contacts that switch Rotary switches set a unique address for each module. together. The address may be set before or after mounting. The built-in TYPE CODE (not seeable) will identify the module Noryl(a)is a registered trademark of GE Plastics,a subsidiary of to the con nt ofse panel. r so as address differentiate between a mod-andGeneral Electric Company. This document is not intended to be used for installation purposes. We try s keep our product information up-to-date and accurate. We cannot cover all sped is , subject to change applications or anticipate all requirements AI. specifications are - without noiIcEi- For more intorrnation; contact Fire^Cite Alarms, One Fire-Lite Place, xar*c, :,� ,, , �a Toll Free FAX: (877)699- pM611�11VG$ARAN����� Made in the U.S.A. Northford, Connecticut 06472. Phone: (800)627 .73, 4105. FAX t3ack:888 388-3299. OF-52130-- Page 1 d 2 SPECIFICATIONS FOR CMF RELAY CONTACT RATINGSfor both CMF and CRF models Normal operating voltage: 15 to 32 VDC. Load Description Application Maximum Current maximum current draw: 5.1 mA (LED on). Voltage Rating Average operating current: 390 pA (LED flashing). Nor}Coded 30 VDG 3.0 A External supply voltage (between Terminals T3 and T4): Resistive Coded 30 VDC 2.0 A Resistive 0.9 A maximum 80 volts (RMS or DC). Non-Coded 110 VDC Drain on external supply_ 2 mA maximum (using internal Resistive Nor-Coded 125 VAC 0.9 A EOL relay). Resistive 30 VDC 0.5 A EOL resistance: 47K ohms. inductive(�=5 ) Coded 1.0 A Temperature range: 32°F to 120'F (0°C to 49"C). ���( L/R=2 ms) Coded 30 VDC Humidity range: 10%to 93%non-condensing (PF=0.35) Non-Coded 125 VAC 0.5 A Dimensions: 4.5" (114.3 mm)high x 4" (101.6 mm) wide,x G7741.'V c 1.25" (31 75 mm)deep. Mounts to a 4" (101.6 mm)square x 2.125" (53-975 mm)deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120"F (0°C to 49"C). Humidity range: 10% to 93% non- condensing. Dimensions: 4.5" ( .3h 1( 01.6 ' ) wide x 1.25"( 1.75 mm)deep. Mounts to a 4"( 01.6 mm)square x 2.125" (53.975 mm)deep box. PRODUCT LINE INFORMATION /� CMF-app Intelligent Addressable Control Module. / CRF-300 Intelligent Addressable Relay Module. SMB500 Optional Surface-Mount Backbox. i \ CB500 Control Module Barrier — required by UL for ` . . /, separating power-limited and non-power lim- ited wiring in the same junction box as \.\. CMF-300. MOUNTING DIAGRAMS Note O8500 Module Barrier, ,. which creates isolated quadrant. r I O I ul ' iE�\ ) ti � i illy I "/ \� I�(` m7 __ It� , y ( ISOLATED \©� - i /- QUADPNT T; A lA\ �oar �(_�� \,J ' it - - 4"(101.6 mm)square x 2.125"(53.975 mm)deep box v��o 2 0i 2 - DF-52130 S f I SPECTR-A-18 U I 1 • Models Available PC2475W SC241575W 302a 5W SC2415 SC241575VV SC241575 SC2430'M 502430 SC2475W 502415 .e' " . ._. SC2495W SC2495 F " SC2411.5 SC24115W SC 77W SC24177 • - 2'1 PC2415W PC2415 PC241575t PC241575 te.,, PC2430W PC2430 PC2475W PC2475 PC2495W PC2495 PC241151 PC24115W u, r PC24177 ` F„24177JV rd B3SCW BBSC Y'e Product Overview cesa. 7vs I ike the original SpectrAlert the SpcctrA{ert ceiling moon, series offer sig++ificant current draw reductions over other ceiling inocuflt strobes arid { r, horn/strobes. SpectrAlrrt's compact design also offers installation savings. The strobe and hone/strobe models mount to a 4'x4'x l;0' hack box, and take up little room jr the making t<n align the l,i k l,ox crwith And the with ron nli s lti c 's,t s round )ha],c, it s not necessary SpectrAlert always lines up. SpcctrAlcrt ceiling mount strobes and horn/strobes arc mailable in . seven different candelas, including 177 candela for sleeping areas-The horn/ strobe's tones are field selectable through the use of a three pusitiern switch located on the back of the unit- Selections include electromechanical and 3 K!I, tones,temporal and non-temporal patterns,and high and low volume. SpectrAlert ceiling strobes and horn/strobes offer a design th , is scnsi_ five to the aesthetic demands of ceiling mount applications.The round shape Taira tans a low profile appearance,similar to that of a smoke detector and provides �n�t approved clearil visible "1�R1 " identification from all angle,. (51 - u :if Nl(itifiF Iaa li�C 1.)f19'.2n1 Engineering Specifications Strobe hail he a System Sensor SpectrAleo Model listed to UL 1971 and he approved for fire protective e'r- c .where ceiling mount strobes are perznrttcd. The strobe 1sha1The strobhe wiree 1 ght�shallconsist of aas a riary signaling noficxenonaflash tap etion 'and ar;d shall (lash at 1T Iz over the strobe's entire operating range- associated lees/reflector system. )-lot.z/strobe shall be a System Sensor $pcctrAlert Model _ listed to U L 19%1 and lli,464 and be approved fu; ire proicct.e service where ceiling mount horn/strobes are permitted.The horn/strobe shall be wired as a primary lli,7 ,icitikinuon appliance and shall flash at 1117 over its entire operating ran wo tone: opt onstrtwo e audibility opuonscOnSISt iand cne n flash lobe and associated lens/reflector stistem. The horn shall shall havethe option to switch her 'ebe a hall h ralczsand powered independentlyof the so pattern. it These the removal sof factory instal edyiuznmp- ;nuiti-position switch. Strobes shat 1 c p P c; y+fires. The horn on horn/strobe models shall operate on a coded or non coded power suppiy- Sotc=-1-he strobes must be powered continuously for the horn to operate_ General specifications - ki diameter 32°to 9-20° F (0°to 49°C) 5.3 oz. (150 grams) 4,x 4'x 1'/" hack box or u'x 4""x 2,' " back box (with skirt) SpectrAiert Mounting Diagrams — — — -.-- 4x4x2'/:" Cif O O BBSCW Strobe or Horn/Strobe with Mounting Plate \' 4 Strobe or Horn/Strobe with Accessory Back Box Skirt Electrical Specifications 16-33 V 6.049,446 24 VDC and FWR' unfiltered - 6,057.778 D424,465 12 io 18 AWG 17-33 V tali`.tias-^?NI ihi lrWRi voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. . the h9CI causes a one-volt voltage drop in the❑otifiC0tlon appliance circuit. Table 1-A: SpectrAlert Strobe UL Max.Current Draw(mA RMS) Table 1-B:Horn UL Max.Current Draw Measurements(mA RMS) Low Electrommhanical — �_—_ ,- : Volume 3000 tV Interrupted 33 73 15 68 _ 64 High Electromechanical I b3 77 78 volume 3000 lit Interrupted 57 40 15/15 i �— i — — iiii - 107 �__ 113 ow Electromechanical 37 >� Volume 197 205 32 33 — 7 197 3000 Hz Interrupted High Electromechanical ay L_ 49 298 325 volume 3000 Hz Interrupted I — —.—.399 489 — Table 1-C: 24V DC Horn/Strobe UL Max.Current Draw Measurements(mA RMS) 15;75 89 9v 1 92 41 128 125 131_- 13a ti0 �222 — ---1— 222J 222 219 >? �_— --- —I,265 269_..__. 266 2r 277 270 27l2 �— — 1.—.— — — —i— 291 290 79� "> 3 296 _ �.__ _— . -- - n96 n91 as3 491 nab 1.77 512 50q 501 — —_—__ Explanation of Published Voltage, Current, and SPL Specifications 17, May 20()4 Underwriters Laboratories changed standard During May 2004, UL also changed the way they list the Ui, 1971 to rccluire that operating current measuremments voltage range of a device- All 12V products will be listed ate made using RMS (root mean square) instead of peak between 8 17.5V and all 24V products will he ii ted ;r average values. RMS measurements more accurately between 16 — 33V_ Those devices are considered "regnlat redid the power consumption of a device since they take ed"- Any product that does not operate within these ranges into account the entire current draw profile including surge, will be listed as a "special application' with its operating repetitive surge, and peak values. the published RMS cur- voltage specified oil the device. rent is the maximum operating current of that device within its operating voltage range- This current lnaximurn may or Notes -- mac- ,tot occur at the endpoints of the voltage range. 1. Current draw for strobe-only products is shown in Table 1 A. 2. 24VDC 2-wire horn/strobe current draw is shown in Table Sit;iilarl;. Oh tests the audibility of devices in accordance 1-C withDL 464 by measuring them across the operating volt ape i,inge to determine the minimum sound pressure level 3- Current draw for other horn/strobe power supplies can be calculated by adding the strobe current in Table 1-A to the produced at any particular setting' horn current in Table 1-B from the chosen settings- F SpectrAlert Dimensions lom Sound Measurements{dBA) �! Lo volt m Electromechanical_ 3000 Nz Interrupted 75 I FiiE,h vplurnct r_I;tctromechaniral _ I I I II t, �z Interrupted 81 j �riw vplpme lectrpfne(:hAni(:0i 79 3000 Hz Internaptcd 7`� ... I l- Ni^,I'`V01 Urr1E Electromechanical --- sn , __- 000 Hzlnternipted G0 I - -"- SpectrAlert Ceiling Mount Strobe fi.fl" f SpectrAlert Ceiling Mount Horn/Strobe Ordering information PC241575W I Ceiling-mount horn/strobe. 24 volt. 15/75 candela. white —_-- cC2n15 Ceiling-mount strobe.24 volt. 15 candela, red PC2430 Ceiling-mount horn/strobe.24 volt: 30 candela- red_ SC2a,5WN . ceiling-mount strobe, 24 volt, 15 candela white PC2430W Ceiling mount horn/strobe, 24 volt. 30 candela-white PC7475 Ceiling mount horn/strobe,24 volt. 75 candela. red SC241, ? Ceiling mount stroke,24 volt, 15/75 candela red 062475/ow Ceiling-mount strobe.24 volt. 15/75 candela,white PC2475W Ceiling-mount horn/strobe,24 volt, 75 candela,white SC2430 Coiling-mount. strobe. 24 volt.. 30 candela,red PC2495 Ccrling-mount hom/stroke: 24 volt. 95 candela. red a v Ceiling mount strobe, 24 volt, 30 candela,white SC2 30 -- — — PC2495W Ceiling mount horn/strobe.24 volt,95 candela white SC2475 Ceiling-mount strobe,24 volt: 75 candela, red _ PC24115 Ceiling-mount horn/strobe,24 volt. 115 candela, red S;,2475Lti Ceiling-mount strobe,24 volt. 75 candela.white — PC24715W Ceiling-mount horn/strobe, 24 volt, 115 candela. white SC2?9`. Ceiling mount strobe, 24 volt,95 candela. red _— —.. SC24a5W J Ceiling-mount strobe, 24 volt,95 candela,white PC24177 Ceiling-mount horn/strobe, 24 volt, 177 candela. red — — . SC241 i5 I Ceiling-mount strobe,24 volt. 115 candela. red PC24177W Ceiling mount horn/strobe.24 volt, 177 candela -- white SC24u15w Ceiling-mount strobe. 24 volt. 115 candela.white _ -- SC241l7 `Ceiling mount strobe,24 volt, 177 candela, red •Circuitr"' Module. 5C7G177Vv Ceiling-mount strobe, 24 volt. 177 candela;white MDL Sync MDLW Sync•Circuitrr Module.white CC2a,5j Ceiling-mount horn/strobe.24 volt, 15 candela, red — - Surface mount back box skirl, red BBSC PC241wv Ceiling-mount horn/strobe, 24 volt. 15 candela,white I Surfac e mount back hoe skirt:white 15/75 Candela,red BBSCW PC24i-X75 Ceiling-mount horn/strobe.24 volt: System Sensor Sales and Service — — system sensor-India System Sensor in China System Sensor—Far East 7 System Sensor Headquarters System Sensor Canada Y Ph:91.124.23/.1770 n-2'00 Ph:86.29.88.'.2,0119 Ph:85.22.191.9003 Fx:91.124237.;118 5325 t?c Avenue Ph:9058120767 Fe:85-22.736.6580 Fx:86-29.8832.5119 St_Chales.'�i 507}',1 r=x.905.81.20771 system Sensor—Russia 3,: 800.S NSOR2 System Sensor Europe System Sensor in Singapore System Sensor-Australia Ph: em Se937,7982 Ph:65.6273.2230 Ph:613.54.281.1.42 Fe. 70.95.937.7983 ..eys 1 .6.95 Ph:44.1403.276500 Fe:613,54.281.172 w+syscn,sen;prG Fx:44.1403.276501 Fe:65.6277.2610 o5tozs.00s-sins t`'n rc5e; %;the riKhr ro cr,argi,crndtrct SDr-riti r alne;,v ithoiri notict- f i F • 1 1 1 1 1 1 1 1$f�r�a��S 4 Models Available L r� P1224MC Hom/Strobe w -x Red White ayr S1224MC S1.224MCW S1224MCP S1224MCPW 51224MCK S122A MCSP Red White . P1224MC P1224MCWP1224MCP P1224MCPW P1224MCK ' 1 "1E P1224MCSP r ' _ Red White TS H12/24 H12/24W . H12/24K Product OverviewV 34v ro �s c7 a t c .� le _ r,E0 Output snrr ro {f r/ t r,hrtle'he `;1(e:,�t ! s;�i-`.fir •_:a11E.IEl-F 'ifs y zs zild si₹ �r �r E.', '§ rt ":.(r,. v .:rYl..1..s.e, r'f d pr f4 5 - -'e itiO and of t,r{„.. ..3€a-.;."... LYt+h tO spi rt SpcctrAlezt selectable output wall-mount horns,strobes,and"horn/strobes offer key performance features long associated with the SpectrAlcrt name The select able candela strobes and horn/strobes offer average current draws that arc not only lower than conventional fixed-candela SpectrAlcrt products,but also lower than similar , . "n selectable candela products.By consuming less current,the ability to connect even more devices per loop is possible,resulting in a lower installed cost. ; : SpectrAlcrt selectable output horns,strobes,and horn/strobes offer the same installation-friendly features synonymous with the SpcctrAlcrt name,such as the option of 2-and 4-wire operation;the ability to use standard site backbones with no encroachment into the box;and universal mounting incorporating the laborsaving Aft strobe and horn/strobe models incorporate a Quick(I k" feature.Such labor-savi new patent-pending voltage booster design that ngs features make wire connections simple and fast, further reducing installed cost- has a more consistent flash bulb voltage over SpectrAlcrt scicctablc output strobes and horn/strobes offer the broadest the range of candela Selections. The benefit to the customer is a high quality strobe device. range of candela options. In addition,the selectable output strobes and horn/strobes ern operate on either 12V or 24V,with ao setting required;the device rceognrzes and self-adusts to the correct current automatically.Temporal 3 or COtrtlnUOus ton"options uL UC continue to be available,in either an Electromechanical or 3kHz pattern LISTED weozNKiros SpectrAlcrt selectable output horns,strobes,and horn/strobes incorp, u rcn- tc e c 1 S: .;v1f1JNn137•.,a the same stylish, low profile design of the conventional SpectrAlcrt products,for M MEA sistcnt and aesthetically pleasing appearance across the entire product line. coil- FM approved 1777 vwweo .77-0Z I. 17Fo?-F Engineering Specifications lire protective service.Horn/strobe shall be wired as a primary , S}cct- lrr;horns,strobes and horn/sirohcs shall he capable of signaling notification appliance and comply with the Americans cooling to a standard 4" x 4" x 1 /z° hack box or a single gang with Disabilities Act requirements for visible signaling 111 n Ces Z' x ?" x I 7J ' hack box using the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage range.ht consist a xenonincluded with cacti SpecirAlcrt product. Also,Specs AkCirrt lcu t Tens/refle- The bc ctorsy5thm�IThe hornfshall have ltwo tone oh tube rd ptions,ttwtod uc[s_when used in conjunction with the accessory y switch between Module,shall he powered from a non-coded power supply audibility options(at 24 volts) and the option to. and shall operate on 12 or 24 volts. 12 volt rated devices shall a temporal 3 pattern and a non-temporal continuous pattern_e powered have an operamig voltage range of 9-17.5 volts. 24-volt 4 33 lt rated Sirobs removal shall o facto ry installed jumper )'he by nitly of the oon horner with /hc devices shall have an operating voltage range or 17 �pcetrAlert products shall have an operating temperature of strobe models shall operate on a coded or non coded power sup- 32° to 120°F and operate from a regulated DC or full wave ply(the strobe must be powered continuously)_ rectified, unfiltered power supply. S.,-, ^nizatit;> ^ ,tltt:e Module shall be.a System Sensor Sync"Cirenit listed riche,hall be a Svstcm Sensor SpeetrAlert Model Co liL 464 and shall he approved for fire protective service The listed to tit, 1971 and be approved for fire protective service-The module shall synchroniic SpcetrAlert strobes at 1 Hi and horns stri he shall he wircd as a primary signaling notification appliance at temporal 3. Also,the module shall silence the horns on horn/ and comply with the Americans with Disabilities Act require- strobe models,while operating the strobes,over a single pair of merits for visible signaling appliances,flashing at 1lic over the wires- the module shall be capable of mounting to a 4i / " x as or srrohe's entire operating voltage range.The strobe light shall con- 4u1/ " u1i 2 /a" xs A) circuit back and shall control ule halltwo be capable Oflmulti)Plc mist Sty Z (cla r of a xenon flash tube and associated Icirs/reflcetor system. one zone synchronization by daisy chaining multiple modules together and re-.synchronizing each other along the chain-The module l torn/Strobe shall be a System Sensor SpcetrAlcrt Model shall not operate on a coded power supply. listed to UL 1971 and ill,464 and shall he approved for Specifications 12V: 8-17.5V; 24V: 16-33V SpeclrAlerl horn/strobe and horn only 8.8 oz. _ —' — work on 'walk tests'" with time (Jura lions of 4 seconds or greater 4" x 4" x 11/2" or 2" x 4" x 1'/8" standard boxes 12V: 9-17.5V; 24V 17-33V _ *Note for Strobes: Do not exceed: 1) 121018 AWG _ 16 33 or 8-17.5 voltage range limit: — 32°F to 120°F (0°C to 49"C) 2) maximum number of 70 strobe lights Strobe and horn/strobe with universal when connecting the MDL Sync module plate 95% as tested per UL464 with a maximum line impedance of 4 5 x 57a x 2'"'/oe' —_._ -- ohms per loop and; 3) maximum line Strobe and horn/strobe with small impedance as required by the fire alai m , Weatherproof(horn and horn/strobes) control manufacturer footprint plate — —.— �2_°F to 150°F (0°C to 66°C) (outdoor strobe only) Horn with universal mounting plate 5,593,569 —40°F to 158°F (-40°C to 70°C) 5 x 5s/-," x 1''/re" 5,914,665 ULC Canadian Models 6,049,446 Horn without mounting plate --40°C to 66°C 12 or 24VDC and FWR unfiltered 7.2ox. spectrAlert Current Draw — r ..:... ne dF s er. un .: "t t r:�; ' - rioo - (' r E 7i ADS '— —_ tTsP.2ht� rn ''!Mt '' S172nMC 15 1.12 127 69 7 1.35 74 Strobes 1.5/7 90 ' 93 75 158 209 � 1.10 208 44.4 57 75 — 127 59 P122_aMC 15 11.2 64 1. 44.4 57 —. o 69 45.7 Horn/StrObe5 1S/75 135 74 127 57-5 y7 75 93 590 57.5 5� 75 30 160 57.5 75 75 158 57.5 57 -. 709 208 57 5 44.4 I 75 I�110 .15-7 57 I H12/24 Horns spectrAiert Mounting and Operation Selectable Horn Tones Candela Selections r Low volume Electromechanical For strobe candela selection, adjust slide switch located on the T.= pera 3000 Hz Interrupted rear of the product while watching the viewing window on the Electromechanical High Volume - Side of the reflector- 3000 Hz Interrupted permissible Candela Settings — _ f:tat Low Volume Electromechanical to 3000 Hz Interrupted- 15 High Volume Electromechanical 75 OK OK 3000 Hz Interrupted 30 0K 75 1 oK DIP Switch Operation Factory DIP Switch 11.0 0K OFF ON Default Viewing window - no,aa oo W High Low Temporal FM— Non- Temporal Electromech- F00—L--] 3000H7 o Base(rear) oc r'f,00 Typical weatherproof mounting with universal plate Plate w88 iv8-36 x t/2"Fiat Head / Screw(4 total) Gasket Conduit _Slot Entrance Locking Rib Paper Liner For Plate Gasket SpectrAlert ordering Information H12/24 Horn, 12/24 volt, red 24 volt, red of224MC Selectable Output Hom/Strobe_12/ H12 24W Horn, 12/24 volt, white ?4MCW (Selectable Output Horn/Strobe, 12/24 volt_whte / 12, L� H12/24K Horn, 12/24 volt, red,weatherproof — —— 24 volt, red. °9.224MCF' Selectable Output Horn/Strobe, 92/ LIlain housing ,__ -.,--- P n oW Selectable Output Horn/Strobe, 17/24 volt. MDL Sync•Circuit Module, red t«.MC. — whiie, plain housing MULW Sync•Circuit Module,white_ MDLA Sync-Circuit Module,red,Canadian model P1224MCK ISelectable Output Horn/Strobe, 12/24 volt, red. Iweatherproot — —.— gync•Cir le.white, Canadian model _ LLL 12 24 volt,red, MDLW_ A . --t red, for si g eI P1224MCSP Selectable Output Horn/Strobe, / Small Footprint Mounting Plate, "FUEGO" housing — 5 MP — gang back box single- 51724 MG Output Strobe, 12/24 volt, red white,for single- 5177_.MC _-- -- -- S MPW Small Footprint Mounting Plate. S1224MCW Selectable Output Strobe: 12/24 volt,white gang back box BBS Surface Mount Back Box Skirt. red 5122 N1Cp Selectable Output Strobe, 12/24 volt, red, plain — —— a __ -- W Surface Mount Back Box Skirt,white S1224MCPW—ISelectabie Output Strobe. 12/24 volt,white. B-M Universal Mounting Plate(replacement). red plain housing D MP white 74 volt, red, D-MPW Universal Mounting Plate (replacement). S7224MCK Selectable Output Strobe, 12/-Selectable Output _ WBB (Weatherproof Back Box S7224MCSP Selectable Output Strobe, 12/24 volt, red, "FUEGO" housing Notes — -- -- MEA,ULC Agency I. ones !;,door models:t.0,ULC,FM,CSFM,M .,1 Urc,uhcrprooE models UL,CSFM (strobe only), weatherroof back box model WP,B.lnstallannn ll of these 5f,ccirAlcrt products arc designed for wall mount only.All weatherproof models m., use p of Icss than 75 r,u dela strobes Wray be permissible andcr the equivalent facilitation clause of the ADAAG(Sec.Z.2).However,it is the responsibility of ,e- erson or entity desirnint;the Bee alarm system to determine the acceprahility of less th:u,75 candela strobes. All 15/75 candela strobes or burn/ I F strobes arc rcc0mnlctidcd for 20'x Z0'rooms or less System Sensor Sales and Service _-.— — — System Sensor-India -- System Sensor in China System Sensor—Far East Ph:85.22-191.9003 Rh-.91.17.4.237-1770 x.7700 System Sensor Headquarters System Sensor Canada Ph.86-79-524-67`.,3 Ex:85 22 791.9000 rz:91 124 237 3118 38"2',phCn Avnnue: Ph:905-817 77/1 x:86.29.574.62`•,9 System Sensor-Russia Si_Cn7)/1.it,li01.74 Fx:905.812.0711 System Sensor-Australia p;,; Op/S!NSOR7 System Sensor in Singapore Ph:70.95-937-7987 System Sensor Europe 3 Ph: 61 3.54.281.147 Ph:65.67 73.27.,0 Fx: 70.95-937 J983 x:6?p/377-649b Oh: 4.1403.89192 Ix: 613-54281.177_ ii0cument�-nn!)gmarul Fx:44.1403.�89197.1 t x:6`.,-627:',.267 0 8U0/73ii 7672 x3 o,w w.5y 5i^msen so"C Or AOS03Z.`r0035/04^y 17U!1 the company reserves me right to change protlVct spec,t'e atiom;withv"t noUr.e. F,CeLITeALarms MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Regulated Load in Standby Main Circuit Board 1 x 0.120000 = 0.120000 4XTMF 0 x 0.005000 = 4-Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.025000 = ANN-80 0 x 0.015000 = ANN-I/O 0 x 0.035000 = ANN-I/O LEDs 0 x 0.000000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.015000 = Addressable Devices BEAM355 and BEAM355S 0 x 0.002000 = BEAM 1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 1 x 0.000300 = 0.000300 SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 11 x 0.000300 = 0.003300 D350RP 0 x 0.000300 = MMF-300 2 x 0.000400 = 0.000800 MMF-300-10 0 x 0.003500 = MDF-300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 9 x 0.000230 = 0.002070 CMF-300 0 x 0.000390 = CMF-300-6 0 x 0.002250 = CRF-300 11 x 0.000270 = 0.002970 CRF-300-6 0 x 0.001450 = 1300 0 x 0.000400 = 8501 BH &B501 BHT 0 x 0.001000 = B224RB Relay Base 0 x 0.000500 = B224B1 Isolator Base 0 x 0.000450 = Current Draw from TB3-EIA-485 0.000000 4 Total Standby Load 0.129440 Page 1 of 4 ®Fire-1Ire°ALarms MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Regulated Load in ALARM iiiflhIu Iul(:1lILujJI1 LIIJJ!J Main Circuit Board 1 x 0.200000 = 0.200000 4XTMF1 0 x 0.011000 = 4-Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.000000 = ANN-80 0 x 0.040000 = ANN-I/O 0 x 0.200000 = ANN-I/O LEDs 0 x 0.010000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.075000 ALL Addressable Devices-Maximum draw 1 x 0.400000 = 0.400000 NAC#1 9 x 0.150000 = 1.350000 NAC#2 0 x 0.000000 = Current Draw from TB3-EIA-485 0.000000 = 3Total Alarm Load 1.950000 Notes: 1) If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 2) Current limitations for NAC circuits TB1 is 2.5 amps per circuit 3) Total alarm current cannot exceed 2.7 amps Page 3 of 4 (&FICe-LITe"ALarmS MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Calculation in Total Sheet Use the total standby and alarm load currents calculated in tables A-2A and A-2B for the following battery calculations (24 or 60 Hrs.) Standby Load Current(Amps) 0.129440 I x 24 = 3.107 AH (5 minutes = 0.084) Alarm Load Current(Amps) I 1.950000 I x 0.084 = 0.164 AH Total Current Load 3.270 AH Multiply by the Derating Factorj 1.2 I = x 1.20 Total Ampere Hours Required 3.924 AH The MS-9050UD can charge this size battery The batteries can be stored in the cabinet NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. MS-9050UD current draw: The required output current is within the panel's limitations Page 4 of 4