08-8588
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8588 FIRE ALARM SYSTEM PERMIT Permit Number: 8588 Address: 7810 GALL BLVD Permit'4!�!pe: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-00700-0000 Improv. Cost: Date Issued: Name: PRIMERICA GROUP ONE Total Fees: 150.00 Address: 3629 MADACA LANE Amount Paid: 150.00 TAMPA FL 33618 Date Paid: 12/10/2008 Phone: (813)933-0629 Work Desc: INSTALLATION FIRE ALARM SYSTEM BLDGING F FIRE ALARM&SECURITY TECHNOLOGI FIRE ALARM 50.00 FIRE INSPECTION FEES 50.00 FIRE PLAN REVIEW FEES 50.00 3 � FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRACTOR SIGNATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 Zephyr hills Fire escue 6907 Dairy Road.. Zephyrhills, FL 33542 Fire Marshal Bus(813) 780-0041 Kerry Barnett Fax(8131)780-0044 E-mail: kbarnett@fire.zephvrhills.f.us Plan Review#: 08-153 Project:Zephyr Commons Bldg"F"Fire Alarm Number of Pages: 1 —plus details packet w/calcs Date:November 28,2008a I have reviewed the plans for the fire alarm installation located at. 83S Gall Blvd and this installation can move forward.Paying for permit acknowledges contractor agrees with the items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. System shall be installed in accordance to NFPA 72,2007 edition. 2. Add outside horn/strobe located in red on plan. 3. Devices shall be addressable.Pulls and ducts for each unit shall be addressed and labeled as such to correspond at alarm panel. 4. Adjust battery cals for additional device.Batteries shall be dated. 5. Phone jacks shall be marked. 6. Breaker shall be labeled and locked off. 7. Zone map shall be located at alarm panel. 8. Strobes shall remain on when system is silenced. 9. Leave extra pull box key with alarm panel. 10.A copy of certificate for UL Listed Central Monitoring Company Inspection Required: 1. Acceptance Test KERRY BARNETT,FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. lNv+iLu/LUU//iut 1i : 4 ;;M ZEPHYRHILLS BUILDING FAX No, O13-780-0021 P, 001/001 813-7,80-0020 City of.Zephyrhllls Firms / Fax-813-780-0021 Permit Application It Date Received 1f? Phone Contaet•for Permit s Owner's Name VLO 11pp��� � t�wrtets Phone Number �] Owner's Address 1 l�/. p C Fee Simple Titleholder Name -1.t Titleholder Phone Number r- - _i r 1 r I Fee Simple Titleholder Address U 0 Job Address 83 '1 'AV t (1 Lot# �"tl —ooIO— t>m—Cax7 gam, JFLp►�/t- 1' / _j Parcel# • -2 —z — 000— Ot' Blo-Hazard Waste Storage-ANNUAL ' [ ] Fumigation Tent • o. Comm Exhaust Kitchen Hood/Duct Q: Hazardous Material(Tier 11 or RQ Facility)ANNUAL ❑ Controlled Bum J. Hood Installation Emergency Generator<30 kW . . ,LP/Natural Ges-installation _ -Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale ' " 'S 'J'� -rZc T?C)A Cv,% Fire.Protection;Maintenance-ANNUAL Places of Aeaentbly-ANNUAL . - ❑I em er Sprinkler ❑ ❑ •-❑ ± a Recreational Bum Fire Alarm ❑ Q ❑ E I j Sparklers - Hood Cleaning ❑ O O O ❑ Sprinkler System Installations, Hood Suppression 0 :❑ • 17 ❑ Standplpee(Sprinkler Sys) • Fire Alarm Installation J Torch Rootinglrar Kettle • Fire Pumps a Waste Tire Storage ANNUAL Fire Works Flammable Application-ANNUAL. . . . [7 . j Valuation of Project • Fuel Tanks Other: • . . Contractor Company Signature ��gistered /N Fee Current . N Address t&r[se# u ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address license# PLUMBER Company . _ • • Signature Registered Y/N Pee Current. Y/ ! ' Address License#. . . MECHANICAL Company . Signature Registered Y/N Fee current [_Y-/N Address " ' 'License# OTHER Company T_ Signature . Registered _Y/Nj Fee Current :Y/Nom- Address : License# . Directions:. . Fill out application completely, Owner&Contractor sign.back of application;notarized(Or,copy of signed contract with owner) - If over$2500,a Notice of commencement is requlred,(Mechanlcal work over$5000) - Supply two(2)sets of drawings with applicable documentation . Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http//approiser paocwgov.com) . €3- t/ it3 ZSa_Fh Us, L. 33342 (C ..).CJ k) !0 1 t FIRE SERVICE USER FEES Occupand'y Nod, 4 Al Plan No.: u Contractor. fl`Yr.! � % , - Business Name: S Billing Address: Business Address: _ r✓ Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual WC Sprinkler $50 lot Alarm N/C .06 at 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-inspection $250 Hoods 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas 6th Alarm $200 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tams $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 per system Camp Fire $25 fl Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices FIRE ALARM SYSTEM Place of Assembly $50 Annum 26 plus Devices $ System Acceptance Fire Protection $25 SUPPRESSION SYSTEMS Recd Acceptance '$50 Flammable Ammon $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annum Dry $50 Fire Wall/Smoke Wag $15 per wall Generator<KW $100 CO2 $50 LP Gas $25 pertanic Generator>30KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 Annum KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Tent 105A0 or greater $15 per ern Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Annum LP installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) Spray Booth $50 ❑Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. WC jJ Emergency Vehicle Act"$50 r.— FALSE ALARM PLANS TOTAL t INSPECTION TOTAL — PERMIT TOTAL TOTAL GRAND TOTAL j Comments: Date: it/wAr Insgctor: Fire Alarm & Security Technologies State Fire Alarm License # EF 20000480 www.fastdetection.com Project Building F Zephyr Commons Kossik and US Highway 301 Zephyrhills, FL Equipment Supplier Fire Alarm & Security Technologies 27251 State Rd. 54 Suite B-14/331 Wesley Chapel, FL 33543 Contact Tim Sorvillo 813-690-4104 UBIVI=D PLANS) B REV 'Y ZEP4YRHILLS u S ICE ' �`, Reviewer: �'f �� 27251 State Road 54 Suite B-14/331 Wesley Chapel, FL. 33543 DF-52418:A•Al-60 MS-9050UD Ffr•UT '`At 'ms Fire Alarm Control Panel with DACT by Honeywell General The Fire•Lite MS-9050UD is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board.This compact, cost effective, intelligent addressable control panel supports up to 50 addres- sable devices of any type of detectors and modules. With an extensive list of powerful features, the MS-9050UD programs I Illlll just like Fire•Lite's larger products,yet fits into applications pre- viously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include remote annunciators and reverse polarity/city box transmitter. (4XTMF) Features • Listed to UL Standard 864,9th edition. • Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. • On-board DACT. • 20 software zones. • Two independently programmable Style Z (Class A) or Style Y(Class B)NAC circuits. NOTIFICATION APPLIANCE CIRCUITS(NACS): • Selectable strobe synchronization for System Sensor, • Two independently programmable output circuits. Circuits Wheelock,and Gentex devices, can be configured for the following outputs: • Remote Acknowledge,Silence,Reset and Drill via address- —Style Y(Class B) able monitor modules. —Style Z(Class A) • Two programmable relays and one fixed trouble relay. —Door Holder Service • Integral 80-character LCD display with backlighting. —Aux Power Source • Real-time clock/calendar with automatic daylight savings • Silence Inhibit and Autosilence timer options. control. • History file with 500 event capacity. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. • Detector sensitivity test capability(NFPA 72 compliant). • Selectable strobe synchronization per NAC. • Maintenance alert warns when smoke detector dust accu- • 2.5 A total power for NACs. mulation is excessive. NOTE:Maximum or total 24VDC system power shared between • One person audible or silent walk test with walk-test log and all NAC circuits and the ANN-BUS is 2.7 A. printout. • Point trouble identification. PROGRAMMING AND SOFTWARE: • Waterfiow(nonsilenceable)selection per monitor point. • Autoprogram(learn mode)reduces installation time. • System alarm verification selection per detector point. • Custom English labels(per point)may be manually entered • PAS (Positive Alarm Sequence) and Pre-signal per point or selected from an internal library file. (NFPA 72 compliant). • Two programmable Form-C relay outputs. • Up to eight ANN-BUS annunciators. • 20 software zones. SLC COMMUNICATION LOOP: • Continuous fire protection during online programming at the front panel. • Single addressable SLC loop which meets NFPA Style 4,6 • Program Check automatically catches common errors not and 7 requirements. linked to any zone or input point. • 50 addressable device capacity (any combination of addressable detectors and modules). • Compatible with Fire•Lite's addressable devices (refer to SLC Wiring Manual). qtr,..,-., 3,y;>. ✓fiY.K.uDfi'^:A� ,, ..._. ,v�"siYhww.;,^,3.„.:., .;€C.. ....9:�;hF3 ;r':.r_ DF-52418:A•04/05/07—Page 1 of 4 User interface BEAM355S: Intelligent beam smoke detector with integral sensitivity test. LED INDICATORS D350PL: Photoelectric low-flow duct smoke detector. • AC Power(green) D350RPL: Photoelectric low-flow duct smoke detector with • Fire Alarm(red) relay option. • Sppervisory(yellow) MMF-300: Addressable Monitor Module for one zone of nor- • Trouble(yellow) mally-open dry-contact initiating devices. Mounts in standard • Alarm Silenced signals(yellow) 4.0" (10.16 cm.)box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B KEYPAD (Class B)or Style D(Class A)IDC. • 16 key alpha-numeric pad. MDF-300: Dual Monitor Module.Same as MMF-300 except it • Acknowledge/Step provides two Style B(Class B)only IDCs. • Alarm Silenced MMF-301: Miniature version of MMF-300. Excludes LED and • Drill(Manual Evacuate) Style D option. Connects with wire pigtails. May mount in • Reset(lamp test) device backbox. MMF-302: Similar to MMF-300,but may monitor up to 20 con- Ordering Options ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. MS-9050UD: Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, CMF-300: Addressable Control Module for one Style Y/Z chassis with transformer, backbox with door, plastic bag con- (Class B/A) zone of supervised polarized Notification Appli- taining screws,cables,key,etc.,manual. ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC DP-51050: Optional dress panel for the MS-9050UD. to power notification appliances. TR-CE: Trim Ring for semi-flush mounting. CRF-300: Addressable relay module containing two isolated BB-26: Battery backbox, holds up to two 25 AH batteries and sets of Form-C contacts, which operate as a DPDT switch. CHG-75. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. BB-55F: Battery box,houses two 55 AH batteries BG-12LX: Addressable manual pull station with interface CHG-75: Battery charger for lead-acid batteries with a rating module mounted inside. of 25 to 75 AH. 1300: This module isolates the SLC loop from short circuit BAT Series: Batteries,see data sheet DF-52397. conditions(required for Style 6 or 7 operation). PRT/PK-CABLE: Cable printer/personal computer interface SMB500: Used to mount all modules except the MMF-301 cable. and M301. PRN-6F: UL listed compatible event printer. Uses tractor-fed MMF-300-10: Ten-input monitor module. Mount one or two paper. modules in a BB-2F cabinet(optional). Mount up to six mod- OPTIONAL MODULES ules on a CHS-6 chassis in a BB-6F cabinet. 4XTMF Reverse Polarity Transmitter Module: Provides a MMF-302-6: Six-zone interface module. Mount one or two supervised output for local energy municipal box transmitter, modules in a BB-2F cabinet(optional). Mount up to six mod- alarm and trouble. Includes a disable switch and disable trou- ules on a CHS-6 chassis in a BB-6F cabinet. ble LED. CMF-300-6: Six-circuit supervised control module.Mount one COMPATIBLE ANNUNCIATORS or two modules in a BB-2F cabinet(optional).Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. ANN-80: Remote LCD annunciator mimics the FACP display CRF-300-6: Six Form-C relay control module. Mount one or ANN-1/O: Input/Output Module for driving graphic annuncia- two modules in a BB-2F cabinet (optional). Mount up to six tors or relays modules on a CHS-6 chassis in a BB-6F cabinet. ANN-S/PG: Serial/Parallel Printer Interface module for con- NOTE: 1) For more information on Compatible Addressable necting printer to FACP Devices for use with the MS-9050UD, see the following data sheets (document numbers):AD355(DF-52386), BG-12LX(OF- ADDRESSABLE DEVICES 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ All feature a polling LED and rotary switches for addressing. CRF Series (DF-52130), CP355 (DF-52383), D350PUD350RPL CP355: Addressable low-profile ionization smoke detector. (DF-52398),H355 Series(DF-52385),1300(DF-52389),MMF-300 P SerieslMDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- SD355: Addressable low-profile photoelectric smoke detec- 302-6(DF-52356),SD355/SD355T(DF-52384). tor. 2) Legacy 300 Series detection devices such as the AD355, CP300/CP350, SD300(T)/SD350(T) and older modules such as SD355T: Addressable low-profile photoelectric smoke detec- the M300, M301,M302, C304,and BG-10LX are not compatible tor with thermal sensor. with LiteSpeed polling. If the SLC contains one of these devices, H355: Fast-response,low-profile heat detector polling must be set for standard CLIP protocol.Please consult fac- tory for further information on previous 300 Series devices. H355R: Fast-response, low-profile heat detector with rate-of- rise option. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). CLIP MODE ONLY BEAM355: Intelligent beam smoke detector. Page 2 of 4—DF-5241 8:A•04/05/07 ADDRESSABLE DEVICE ACCESSORIES Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. End-of-Litre Resistor Assembly(R-47K and R-3.9K): 47k ohm supervises the MMF-300, MDF-300, MMF-301, and N-ELR Mounting Plate: Single End-of-Line resistor plate CMF-300 module circuits. 3.9k ohm End-of-Line Resistor required for use in Canada. assembly supervises the MMF-302 module circuit. These resistors are included with each module. I Wiring Requirements While shielded wire is not required,it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference.Wire size should be no smaller than 18 AWG(0.78 mm2)and no larger than 12 AWG(3.1 mm2).The wire size depends on the length of the SLC circuit.Use the following table to determine the specific wiring requirements for the SLC.(Refer to the panel manual for complete details.) CIRCUIT CONNECTIONS WIRE REQUIREMENTS Recommended Circuit Wire Type and Circuit Type Function Limitations Max.Distance Wire Gauge and Compatible Brands Feet(meters) 12 AWG(3.25 mm2):Genesis 4410, Signal 98230,Belden 9583,WPW999 14 AWG(2.00 mm2):Genesis 4408&4608 Twisted,shielded pair Signal 98430,Belden 9581,WPW995 40 ohms maximum per 10,000(3,000 m) 16 AWG(1.30 mm2):Genesis 4406&4606 length of Style 6 and 7 8,000(2,400 m) Signal 98630,Belden 9575,WPW991 loops. 40 ohms per 4,875(1,450 m) Direct Burial Cable Isotec branch maximum for Style 3,225(980 m) NP713110VNQ-S 4 loops 18 AWG(0.75 mm2):Genesis 4402&4602 Signal 98300,Belden 9574,WPW975 SLC loop Connects to Direct Burial Cable Isotec (power-limited) Addressable NP714110VNQ-S Devices 12 AWG(3.25 mm2):Belden 5020UL& Twisted,unshielded pair 6020UL,Genesis WG-4315&WG-4515 40 ohms maximum per 10,000(3,000 m) 14 AWG(2.00 mm2):Belden 5120UL& length of Style 6 and 7 8,000(2,400 m) 6120UL,Genesis WG-4313&WG-4513 loops. 40 ohms per 4,875(1,450 m) 16 AWG(1.30 mm2):Belden 5220UL& branch maximum for Style 3,225(980 m) 6220UL,Genesis WG-4311&WG-4511 4 loops 18 AWG(0.75 mm2):Belden 5320UL& 6320UL,Genesis WG-4306&WG-4506 Untwisted,unshielded 3,000(900 m) 12-18 AWG(3.25-0.75 mm2)using listed paira wire ANN-BUS Connects to Twisted,shielded pair with (EIA-485) annunciator mod- a characteristic imped- 6,000(1,800 m) 18 AWG(0.75 mm2) (power-limited) ules ance of 120 ohms Connects to remote PC com- Twisted,shielded pair 50(15 m) 18 AWG(0.75 mm2)minimum (power-limited) puter Maximum loop wire resis- MMF-300 and Initiating Device tance is 40 ohms for the 2,500(760 MMF-301 Circuit MMF-300 and 20 ohms for m) 12-18 AWG(3.25-0.75 mm2) (power-limited) the MMF-301 No more than a 2.4 volt MMF-302 Initiating Device drop allowed at end of cir- 2,500(760 m) 12-18 AWG(3.25-0.75 mm2) (power-limited) Circuit cuit. Maximum loop wire resistance is 25 ohms Distance limitation In alarm,no more than a CMF-300 Notification Appli- 1 2 volt drop allowed at set by 1.2 volt 12-18 AWG(3.25-0.75 mm2) (power-limited) ance Circuit end of circuit maximum line drop a)When using untwisted,unshielded wire,full conduit is recommended for optimum EMI/RFI protection. DF-52418:A•04/05/07—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic • Intelligent Signalling Line Circuits.......................................1 components may be adversely affected by extreme tempera- • Addressable device capacity............................................50 ture ranges and humidity. Therefore, it is recommended that Programmable software zones.........................................20 this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60—80°F. • Annunciators......................................................................8 Electrical Specifications NFPA Standards The MS-9050U0 complies with the following NFPA 72 Fire AC Power: 120 VAC,60 Hz,0.3 A. Alarm Systems requirements: Battery: Two 12 V 18 AH lead-acid batteries.Battery Charger —LOCAL (Automatic, Manual, Waterflow and Sprinkler Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of Supervisory). two 18 AH batteries.) —AUXILIARY(Automatic, Manual and Waterflow)(requires Communication Loop: Supervised and power-limited. 4XTMF). Notification Appliance Circuits: Terminal Block provides —REMOTE STATION (Automatic, Manual and Waterflow) connections for two NACs,Style Y(Class B)or.Style Z(Class (Where a DACT is not accepted, the alarm, trouble and A). Special Application power. Power-limited, supervised cir- supervisory relays may be connected to UL 864 listed cuitry. Maximum signaling current per circuit: 2.5 A. End-of- transmitters. For reverse polarity signaling of alarm and Line Resistor:4.7 kohm,1/2 watt(PIN 71252 UL listed)for Style trouble,4XTMF is required.) Y (Class B) NAC. Refer to the Fire-Lite Device Compatibility —PROPRIETARY(Automatic,Manual and Waterfiow). Document for listed compatible devices. —CENTRAL STATION (Automatic, Manual and Waterfiow, Two Programmable Relays and One Fixed Trouble Relay: and Sprinkler Supervised). Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays,nonpower-limited,nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- 9050U0 control panel. In some cases, certain modules may Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x not be listed by certain approval agencies,or listing may be in 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x process.Consult factory for latest listing status. 16.65" (42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • UL:S624 • FM approved Shipping Specifications • CSFM:7165-0075:210 Weight:26.9 lbs.(12.20 kg.)Dimensions:20.00"(50.80 cm.) MEA:442-06-E high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH L1teSpeedTM is a trademark;and FireLite®Alarms®and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2007 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. IS0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. UUIDE]IIIII&MMIMCTilUft All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com :_:YID➢bdry a`z !'".s"s'5; -F ...:sb s"..x Ptnd ,w&e', 74222Wfld-Z. :: w . . wwn „-r;.• #,�.4,rv.. Page 4 of 4—DF-52418:A•04/05/07 January 26, 2005 DF-52185•B-150 LCD-80F Flre•LITe)ALarms 80-Character Liquid Crystal Display Remote Fire Annunciator www.firelite.com Section: Annunciators GENERAL California State Fire The LCD-80F is a compact, cost-effective, 80 character, L Marshal backlit LCD remote Fire Annunciator for use with the Fire-Lite MS-92000D and MS-9600 Fire Alarm Control Pan- els(FACPs).The LCD-80F displays complete system point LISTED CS635 status information and includes control switches for remote S2424 control of critical system functions. f M Up to 32 LCD-80Fs may be connected onto the EIA-485 M EA terminal port (TB7)of each FACP. The LCD-80F requires 72-01-E APPROVED no programming,which saves time during system commis- sioning. FEATURES • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. • System status LEDs for Power,Alarm,Trouble, I sE Supervisory and Alarm Silenced. • No programming necessary—LCD-80F con ""° nects to the terminal port(TB7)on the FACP. ° • Displays device type identifiers, individual point alarm,trouble or supervisory, zone and custom alpha labels. • Time-and-date display field. Aesthetically pleasing design. LCD-SOF • May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). The LCD-80F provides the FACP with up to 32 remote se- Up to 32 LCD-80F annunciators per FACP. rially connected annunciators-All field-wiring terminations • on the LCD-80F use removable, compression-type termi- • Plug-in terminal blocks for ease of installation and ser- nal blocks for ease of wiring and circuit testing. vice. Communication between the FACP and the annunciators • Can be remotely located up to 6,000 feet(1828.8 m)from is accomplished over an EIA-485 serial interface, which the FACP. greatly reduces wire and installation cost over traditional • Local piezo sounder with alarm and trouble resound. systems- Six wires total are required: four for the EIA-485 • Semi-flush mounts to 2.188"(5.556 cm)minimum deep, communications(two in and two return);and two for the 24 three-gang electrical box(Fire-Lite P/N 10103)or three- VDC regulated power. Dip switches control local functions gangable electrical switchbox. such as:piezo disable,control switches/key-switch disable, • Surface-mounts to Fire•Lite SBB-3 surface backbox transmit/receive mode. OPERATION INSTALLATION The LCD-80F annunciator provides the FACP with point The LCD-80F can be semi-flush mounted to a 2.188"(5.556 annunciation with full display text on an 80-character LCD cm)minimum deep,three-gang electrical box(Fire-Lite P/N display. The LCD-80F also provides an array of LEDs to 10103) or three-gangable electrical switchboxes- Alter- indicate system status, and includes control switches for nately, an SBB-3 surface backbox is available for surface- remote control of critical system functions. mount applications- This dc Ala is is a Honeywell tocompany '�O �oO� This document is not intended to be used for installation purposes.We try to keep �r�7 our product information up-to-date and accurate. We cannot cover all specific � T applications or anticipate all requirements. All specifications are subject to change without notice. EN61NEBUN6 8 MAI11111K 811NG For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, QUALITY SYSTEMS Made in the U 5 A. Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105 DF-52185-01/26/05 Page 1 of 2 PRODUCT LINE INFORMATION LCD-80F 80-character,backlit,LCD Fire Annunciator with 10103 Three-gang electrical box, minimum 2.188" control switches for remote control of system (5.556 cm)deep, for semi-flush mount applica- functions, and key-switch lock. tions. SBB-3 Three-gang surface backbox for surface-mount applications. LCD-80F TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft.(1828.8 m)between EACH DEVICE in the EIA-485 loop LCD-80F LCD-80F Terminal Mode (2-wires) �� � �► I ��O C J F r--►i Lu l� O i' 24 VDC(2-wires) i LCD-80F Up to 6,000 ft.(1828.8 m) I � back from last device I 1 to end of EIA-485 loop pC;C , it j Terminal Mode EIA-485 return Addressable (2-wires) Fire Alarm Control Panel Notes: 1) EIA-485:Maximum of 6,000 feet(1828.8 m)cable length from 3) Between each LCD-80F annunciator are four wires:a twisted- FACP to LCD-80F annunciators,6.000 ft.cable length between shielded pair for data communications and a pair for 24 VDC each LCD-80F and 6,000 ft.from the last LCD-80F back to the power. The return circuit only requires two wires(twisted) FACP.Circuit is power-limited, for data communication supervision,wired from the last LCD- 2) Up to 32 LCD-80F annunciators may be used on the EIA-485 80F annunciator on the loop. circuit.When multiple LCD-80Fs are used,the FACP will re- quire additional power supplies(refer to panel documenta- tion). MOUNTING TO BACKBOX(ES) Mounting The LCD-80F annunciators can be semi-flush mounted in Holes(4) a three-gang electrical box with a minimum depth of 2.188" LCD-80F flange (5.556 cm) (Fire•Lite P/N 10103)- � — — - The LCD-80F annunciators can be mounted in three FIRE ALARM ANNUNCIATOR r gangable electrical switchboxes connected together. _� - } ' NOTE:Alternately LCD 80F annunciators can be mounted FIRE-LITE ALARMS, INC. to the SBB-3 surface backbox for surface-mount applica- y SYSTEMS ALL NORMAL Lions. + L1 1:06A 032001 Electrical Installer's Note: This annunciator may not fit SilAc �sl �yye, m ,r. easily into a standard 3-gang electrical box if locking clamps Ack51M (�.ai �._ '� are used to secure wiring entering the rear or side knock- I _ outs. Only use the TOP or BOTTOM knockouts to bring wiring into a standard 3-gang electrical box- 5.813"(14.764 cm) wide x 4.0"(10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (Fire•Lite P/N 10103, shown at right). Page 2 of 2 — DF-52185•01/26/05 July 8,2004 DF-52301 •D-025 FCPS-24FS6 FiFire-LIT(3rALarms 24 Volt, 6 Amp Remote Power Supply www.firelite.com Section: Power Supplies/Accessories California GENERAL Fop 1 ` State Fire �tYY�I i{ . ' Marshal The FCPS-24FS6 is a compact, cost-effective, 6-amp re 7315-0075:206 mote power supply with battery charger. The FCPS-24FS6 APPROVED """''j' may be connected to any 12-or 24-volt Fire Alarm Control LISTED M EA Panel (FACP) or may stand alone. Primary applications 32424 include Notification Appliance (bell) Circuit (NAC) expan- 219-02-E sion(to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B(Style Y)or Class A(Style A, with ZNAC-4 option module). Alternately,the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES • UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. • Operates as a sync follower or a sync generator(default). * See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander model or jumpered permanently on [stand- alone mode]). Optional mounting kit, PIN 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300)for alarm activation_ Four ClassB(StyleY)orfourClassA(StyleZ)(withZNAC- • AC trouble report selectable for immediate or 8 hour 4 Module) Notification Appliance Circuits. delay_ 6.0 A full load output(3.0 A maximum per circuit)in NAC • Works with virtually any UL 864 fire alarm control which expander mode (UL 864). utilizes an industry-standard reverse-polarity notifica- 4.0 A continuous output in stand-alone mode(UL 1481). tion circuit (including unfiltered and unregulated bell In stand-alone mode, output power circuits may be power). configured as resettable(reset line from FACP required) • Requires input trigger voltage of 9.0- 32 VDC. or non-resettable or a mix of two and two. • Self-contained in compact, lockable cabinet (15" [38.1 • Fully regulated and filtered power output (optimal for cm]H x 14.5"[36.8 cm]W x 2.75"[7.0 cm]D). powering four-wire smoke detectors, annunciators and • Includes integral battery charger capable of charging up other system peripherals requiring regulated/filtered to 18 AH batteries. Cabinet capable of housing 7.0 AH power). batteries. • Power-limiting technology meets UL power limiting re- • Battery charger may be disabled via dip switch for appli- quirements. cations requiring larger batteries. Form-C normally-closed trouble relay • Fixed, clamp-type terminal blocks accommodate up to • Fully supervised power supply. battery and Notification 12 AWG(3.1 mm2)wire. Appliance Circuits. • Selectable earth fault detection. Fire Lite® Alarms is a Honeywell company. !S! 9001 This document is not intended to be used for installation purposes. We try to kep ouncip ro a ll information up-to-date and accurate. We cannot cover all specific applications or a requirements. All specifications are subject to change without notice- NCIIEC8MIWYNICiH1IN6 For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. QUALITY SYSTEMS Phone. (800) 627-3473, Toll-Free FAX- (877) 699-4105- DF-52301 07108/04 — Page 1 of 2 STANDARDS and CODES Example 2 The FCPS-24FS6 complies with the following standards: Use the FCPS-24FS6 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and NFPA 72 National Fire Alarm Code. resettable power options are available. • UL 864 Standard for Control Units for Fire Alarm Sys Resettable outputs are created by connecting the resettable Sys- tems (NAC expander mode)UL 1481 Power Supplies for Fire Alarm Systems output from the FACP to one or both of the FCPS-24FS6 • inputs. (stand-alone mode). Example 3 SPECIFICATIONS Use addressable control modules to activate the FCPS- Primary(AC)Power 24FS6 versus the FACP Notification Appliance Circuits. This • FCPS-24FS6: 120 VAC 60 Hz, 3.2 A maximum typically allows for mounting the FCPS-24FS6 at greater Wire size: minimum 14 AWG(2.0 mm2)with 600V insu- away from he applications.CP while expanding system architecture in various lation. Control Input Circuit In this example, an addressable control module is used to • Trigger Input Voltage: 9.0 to 32 VDC. activate the FCPS-24FS6 and an addressable monitor Trigger Current: 2.0 mA(16-32 V). module is used to sense FCPS-24FS6 trouble conditions. Local auxiliary power output from the FCPS-24FS6 pro- per input) 1.0 mA(9 16 V). vides power to the addressable control module. Trouble Contact Rating • 5.0 A at 24 VDC. •Fire-Life's MS-9200, MS-9200OD, (198-point)or MS-9600 (636 Auxiliary Power Output point)addressable FACPs have the capability of locating control • Specific Application Power- 500 mA maximum. and monitor modules up to 10,000 feet(3048 m)away. Output Circuits +24 VDC filtered, regulated. Sync Follower/Generator Note: In some installations, it 3-0 A maximum for any one circuit. is necessary to synchronize the flash timing of all • 4.0 A maximum total continuous current for all outputs strobes in the system for ADA compliance. Strobes (Stand-alone mode). accomplish this by monitoring very short timing pulses 6.0 A maximum total short-term current for all outputs on the NAC power,which are created by a Fire Alarm (NAC Expander mode). Control Panel such as the Fire-Lite MS-9600. When Secondary Power(Battery)Charging Circuit installed at the end of a MS-9600 NAC wire run,this Supports lead-acid batteries only- power supply can track(i.e. "follow")the strobe synchro- Float Charge Voltage: 27.6VDC. nization timing pulses on the existing NAC wire run. This • Maximum Charge Current: 1.5 A. maintains the overall system flash timing of the addi- Maximum Battery Capacity: 18 AH- tional strobes attached to this power supply. When this power supply is configured (via DIP switch ORDERING INFORMATION settings) as a "sync follower," this supply's NAC outputs FCPS-24FS6 Remote charger power supply (120 track the strobe synchronization pulses present at this VAC). Includes main printed circuit supply's sync input terminal- The pulses are originated board, transformers, red enclosure, and from an upstream FACP or other power supply. installation instructions. When this power supply is configured (via DIP switch settings) as a "sync generator;" this supply's sync input FCPS-2456RB Replacement mother board. terminal are not used. Rather, this power supply is the PN 90286 FCPS-24F Module Mounting Kit originator of the strobe synchronization pulses on this power supply's NAC outputs. In"sync generator" mode, ZNAC-4 Class A(Style Z) NAC option module the sync type (System Sensor,Wheelock, or Gentex) is A77-716B 12/24 VDC end-of-line relay for selectable via DIP switch settings. monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt,7.0 AH(two required). APPLICATIONS Example 1 Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B(Style Y)outputs or 4 Class A (Style Z)outputs(using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 -- DF-52301 07108/04 May 3,2001 DF-52149 E-150 FiFire-LIT45ALarms SD350(A)/SD350T(A) Addressable Photoelectric Detectors www.firelite.com Section: Addressable Devices GENERAL The SD350 and SD350T Addressable, low-profile plug-in Photoelectric Detectors use a state-of-the-art photoelectric �` U� �pFC41rFo9 sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's MS-9200 sad and MS-9600 Addressable Fire Alarm Control Panels. The F<raE�ayr SD350T adds thermal sensors that will alarm at a fixed tem- perature of 135"F. Since this detector is addressable,it will help emergency personnel quickly locate a fire during its early 7272-0075.194 stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (Part No. RA400Z). FEATURES SLC Loop fit' • 2-wire loop connection. - Unit uses base for wiring- ' Addressing • Addressable by device. • Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) entry of address D 0 Architecture • Unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. SD350 • Sleek,low-profile design. Other System Features • Integral communications and built-in type identification. • Fully coated circuit boards and superior RE/transient pro- • Built-in tamper-resistant feature. tection. • Removable cover and insect-resistant screen for simple • 94-VU plastic flammability rating. field cleaning. • Low standby current. Operation Options - Withstands air velocities up to 1,500 feet-per-minute with- • Remote LED output connection(Part No. RA400Z). out triggering a false alarm. APPLICATIONS • Factory preset at 1.5%nominal sensitivity for panel alarm threshhold level. Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability,especially where • Visible LED"blinks"when the unit is addressed(communi- smoldering fires are anticipated.Ionization detectors are of- eating with the fire panel)and latches on in alarm- ten better than photoelectric detectors at sensing fast,flam- Mechanicals ing fires. • Sealed against back pressure CONSTRUCTION • Direct surface mounting or electrical box mounting. These detectors are constructed of LEXAN®in an off-white - Mounts to: single-gang box, 3.5" or 4" octagonal box, or color.The SD350(T)plug-in low-profile smoke detectors are 4"square electrical box(using a plaster ring-included), designed to commercial standards and offer an attractive ap- pearance- This document is not intended to be used for installation purposes. We try to keep our 1S0 �00� product information up-to-date and accurate. We cannot cover all specific applica Lions or anticipate all requirements. All specifications are subject to change without notice For more information,contact Fire•Lite Alarms,One Fire-Lite Place,Northtord, 1 Connecticut 06472- Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX1 61CIPEERIIS&MMHf&CM110 Made in the U_S.A. Back:888 388-3299. DF-52149 Page 1 of 2 INSTALLATION ' PRODUCT LINE INFORMATION The SD350(T) Plug-In Detectors use a detatchable mount- SO350(A) Addressable Photoelectric Detector(B350LP ing base to simplify installation, service and maintenance, base included). (A) model has ULC listing. Mount base on box which is at least 1.5 inches (3.81 cm) SD350T(A) Same as above with thermal element deep. Suitable boxes include: (B350LP base included).(A)model has ULC listing. • 4"(10.16 cm)square box with plaster ring. RA400Z Remote LED. Mounts to a single-gang box. • 4" (10 16 cm)octagonal box. B350LP Plug-in detector base (included).Diameter: 6.1"(155 mm).Mounting:4"(102 mm)square • 3.5" (8.89 cm)octagonal box. box with or without plastic ring, 4" octagon • Single-gang box. box,3 1/2"octagon box or single gang box. All mounting boxes have a minimum depth of NOTE:Because of the inherent supervision provided by the All (3 mm). SLC loop, end-of-line resistors are not required. Wiring "T- B224RB Plug-in 5 System Sensor relay detector base. taps"or branches are permitted for Style 4(Class B)wiring. Diameter:6.2"(157 mm). Mounting:4"(102 OPERATION mm)square box with or without plastic ring, 4" octagon box, 3 1/2" octagon box. All Each SD350(T) uses one of 99 possible addresses on the mounting boxes have a minimum depth of MS-9200 Signaling Line Circuit(SLC) or up to 318 (159 on 1.5"(38 mm). each loop)on the MS-9600 SLC.It responds to regular polls 8501 BH Plug-in System Sensor sounder detector from the system and reports its type and status. base.Diameter:6.0"(153 mm). Mounting:4" The SD350(T) Addressable Photoelectric SensorTM unique (102 mm)square box with or without plastic unipolar chamber responds quickly and uniformly to a broad ring. Mounting box has a minimum depth of range of smoke conditions and can withstand wind gusts up 1.5"(38 mm). to 1,500 feet-per-minute without sending an alarm level sig- nal. Because of the unipolar chamber,the SD350(T)is ap- proximately two times more responsive than most photoelec- tric sensors.This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested(required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to an MS-9200 or MS- 9600 addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 and MS- 9600 for record keeping. SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched"ON"). Air velocity: 1,500 ft./min- (7.6 m/sec.) maximum. Diameter:5.0 inches(12.7 cm),6.2 inches(155 mm)installed in B350LP Base. Height: 1.7 inches(43 mm) installed in B350LP Base. Weight: 3.6 oz. (102 g). Operating Temperature Range:0°to 49°C (32°to 120°F) SD350. Operating Temperature Range:0°to 38° C (32°to 100°F) SD350T. Temperature:0°-49°C(32° - 120°F). Relative humidity: 10%-93%, non-condensing. Page 2 of 2 — OF-52149 June 25, 2001 DF-52167 E-700 p H350/H350R FI re•LuTe®ALarmS Intelligent Addressable Thermal (Heat) Detectors for use with MS-9600 www.firetife.com Section: Addressable Devices GENERAL �S �N 7270-0075:195 The H350 and H350R model thermal detectors are address- able v o sensors that use a state-of-the-art thermistor sensing circuit for fast response-These sensors are designed to pro- vide open area protection and are intended for use with the SeavtoE MS-9600 fire alarm control panel. Both the H350 and H350R sensors provide fixed tempera- ture alarm detection at 135°F. The H350R sensor responds to rate-of-rise conditions of greater than 15°F/minute. Two LED's on each sensor light to provide a local, visible sensor indication.Remote LED annunciator capability is avail- .4 able as an optional accessory (Part No. RA400Z). FEATURES SLC Loop • Two-wire SLC loop connection. Addressing • Addressable by device. • Direct Decade 01-159(MS-9600)entry of address. H350 Architecture • Sleek,low-profile,stylish design. • State-of-the-art thermistor technology for fast repsonse. • Integral communications and built-in device-type identifica- APPLICATIONS tion. • Built-in tamper resistant feature. Use thermal detectors for protection of property. • Built-in functional test switch activated by external magnet. CONSTRUCTION Operation • Factory preset at 135°F(58°C). These detectors are constructed of Bayblend®in an off-white • Rate-of-Rise model(H350R), 15°F(8.3°C)per minute. color. • 360°-field viewing angle of the visual alarm indicators(two The H350 and H350R plug-in intelligent thermal detectors bicolor LEDs). LEDs blink green in Normal condition and are designed to commercial standards and offer an attrac- turn on steady red in Alarm. tive appearance. • Visible LEDs"blink"every time the unit is addressed. INSTALLATION Mechanicals • Sealed against back pressure. The H350 and H350R plug-in intelligent thermal detectors • SEMS screws for wiring of the separate base. use a detachable base to simplify installation, service and • Designed for direct-surface or electrical-box mounting. maintenance. Installation instructions are shipped with each • Plugs into separate base for ease of installation and main- detector. tenance. Mount base (all base types)on box that is at least 1.5"(38.1 • Separate base allows interchange of photoelectric,ioniza- mm) deep. Suitable boxes include: tion and thermal sensors. • 4"(101.6 mm)square box. Other System Features • Remote test feature from the panel. • 3 1/2"(88.9 mm)or 4"(101.6 mm)octagonal box. • Walk test with address display. • Single-gang box(except relay or isolator base). - Low standby current. • 94-5V plastic flammability rating NOTE:Because of the inherent supervision provided by the Options SLC loop, end-of-line resistors are not required. Wiring "T- • Remote LED output connection to optional RA400Z remote traps"or branches are permitted for Style 4(Class"B")wiring LED annunciator. • Recessed(RMK400)or surface(SMK400)base mounting kits. Baybtend®is a registered trademark of Bayer Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information,contact Fire•Lite Alarms,One Fire Cite Place,Northford, Connecticut 06472. Phone (800)627-3473, Toll Free FAX: (877)699-4105, FAX 9YCIPE911PR&MANNUTRRINR Made in the U.S.A. Back'888 388-3299. DF-52167 — Page 1 of 2 OPERATION Each H350 or H350R uses one of 159 possible addresses (MS-9600)on a control panel SLC loop. It responds to regu- lar polls from the control panel and reports its type and the .status. If (t receives a test command from the panel (or a local magnet test),it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel.The H350 and H350R offer features and performance that represent the latest in ther- mal detector technology. SPECIFICATIONS Diameter: 6.1" (155 mm) installed in B35OLP. Height: 2.0" (51 mm). Weight: 5 oz. (150 gm). Installation temperature: -4°to 100° F (-20°to 38°C). Humidity range:10%to 93%relative humidity(non-condens- ing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B35OLP flanged base. Fixed Temperature setpoint: 135° F (57°C). Rate of Rise detection: Responds to greater than 15°F/min- PRODUCT LINE INFORMATION H350 Intelligent thermal sensor(B35OLP base in- cluded). H350R Same as above with Rate-of-Rise feature. RA400Z Remote LED. Mounts to a single-gang box. B35OLP Plug-in detector base(included).Dimensions: 6,1"(155 mm. Mounting:4"(102 mm)square box with or without plastic ring,4"octagon box, 3 1/2" octagon box or single gang box. All mounting boxes have a minimum depth of 1.5" (38 mm). M02-04-00 Test magnet. B224RB Plug-in System Sensor relay detector base. Diameter:6.2" (157 mm). Mounting: 4"(102 mm)square box with or without plastic ring, 4"octagon box, 3 1/2"octagon box- All mounting boxes have a minimum depth of 1.5" (38 mm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0"(153 mm). Mounting: 4"(102 mm)square box with or without plastic ring. Mounting box has a minimum depth of 1.5"(38 mm). Page 2 o1 2 - DF-52167 May 2,2001 DF-52176 E-600 • D350P/D35ORP FI Ce-LITE�®ALc3r1�lS Photoelectronic Duct SmokeDetector www.firelite.com Section: Addressable Devices GENERAL 5r,„ The new D350P and D350RP addressable photoelectric duct r F M smoke detectors are used exclusively with the Fire•Lite MS- 9 ,•�f,; 9200 and MS-9600 addressable fire alarm control panels. Senv cE Since these duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early 3240 0075:159 stages, potentially saving precious rescue time while also reducing property damage.The D350RP otters the same tea- lures as the D350P while adding a Form-C relay. 4W An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct sys- fem is thus distributed to the entire building. Smoke deter ; tors for use in air duct systems sense the presence of smoke in the duct The D350P and D350RP air duct smoke detectors are pho- toelectric detectors,combining this detection technology with an efficient housing design that samples air passing through the duct,allowing detection of a developing hazardous con- D350P dition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector.With the D350RP,appropriate action can be taken to shut off fans and blowers and to change over air handling systems, etc. This can isolate toxic smoke and fire gases or prevent their distribution thoughout areas served by the duct system. control panel specifications for wiring requirements before Two LED's on each detector light to provide a local, visible wiring the detector loop.The D350P/D350RP detector is de- alarm indication. A remote alarm output is provided for use with auxiliary devices.The D350P and D350RP have remote signed for ease of wiring; the housing provides a terminal strip with clamping plates. test capability with the RTS451/RTS451 KEY Remote Test Remote LED annunciator capability is available as an op- Station,as well as remote communication using the RA400Z tion. Each duct smoke detector can only be wired to one re- alarm LED. mote accessory. APPLICATIONS SPECIFICATIONS Duct smoke detectors have the following limitations: • NOT a substitute for open area smoke detectors. D350POperating voltage range: 15 to 32 VDC. • NOT a substitute for early warning detection. • NOT a replacement for a building's regular fire detection Standby current: 300 pA @ 24 VDC (one communication system. every 5 seconds with LED blink enabled). Operating temperature range:32°to 131°F(0°to 55°C). Call your Fire•Lite distributor for a copy of System Sensor's Humidity range: 10%to 93%(non-condensing). application guide, Proper Use of Smoke Detectors in Duct Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 Applications(A05-1004-00). meters/min.). INSTALLATION Dimensions: 14-375" (365.125 mm)wide x 5.500"(13.970 Wiring: For signal wiring (the wiring between detectors or mm)high x 2.750"(69.850 mm)deep. from detectors to auxiliary devices), it is recommended that Options: RTS451, RTS451KEY, RA400Z. Separate auxil- single conductor wire be no smaller than 18 AWG(0.75 mm). iary power not required. The duct smoke detector terminals accomodate wire sizes up to 12AWG (3.25 mm').Flexible conduit is recommended D35ORP for the last toot(30.48 cm)of conduit:solid conduit connec- Operating voltage range: 15 to 32 VDC (comm. line volt bons may be used if desired age)and 24 VACNDC or 120/240 VAC auxiliary power(sepa- Smoke detectors and alarm system control panels have speci- rate source). NOTE: The D350RP requires a separate aux- fications for Signaling Line Circuit(SLC)wiring. Consult the iliary source. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without rr••��� notice. For more information,contact Fire•Lite Alarms,One Fire-Lite Place,Northford, Q� + Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX EN61EE61NG S MANIFIIC11611i Back:888 388-3299. DF-52176— Page 1 of 2 Standby current: 300 1A @ 24 VDC (one communication PRODUCT LINE INFORMATION D350P Addressable duct detector housing with every 5 seconds with LED blink enabled). Auxiliary power current draw(@ 24 VDC):26 mA(standby), photolectric smoke detector. 87 mA (alarm). D350RP Addressable duct detector housing with Operating'temperature range:32°to 131°F(0°to 55°C). photolectric smoke detector and DPDT relay. Humidity range: 10%to 93%(non-condensing). ST-1.5 Metal sampling tupe,duct widths 1'to 2'(see table at left for metric lengths). Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 ST-3 Metal sampling tupe,duct widths 2'to 4'. meters/min.). ST-5 Metal sampling tupe,duct widths 4'to 8'. Dimensions: 14.375" (365.125 mm)wide x 5.500"(13.970 ST-10 Metal sampling tupe,duct widths 8'to 12'. mm)high x 2.750"(69.850 mm)deep. Options: RTS451, RTS451 KEY, RA400Z. APA451. RA400Z Remote annunciator alarm LED- RTS451 Remote test station. Mounts in single-gang Relay contact ratings:2 Form-C, DPDT, 10 A @ 250 VAC, box. Includes red alarm LED and magnet 10 A @ 30 VDC (resistive). Minimum switching current of test switch. 100 mA @ 5 VDC. RTS451 KEY Key-activated remote test station. INLET TUBE SELECTION F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. Outside Duct Width Inlet Tube* P48-55-00 Replacement end cap for plastic sampling tube. Up to 2 feet(0.6096 m) ST-1.5 P48-21-00 Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. 2 to 4 feet(0.6096 to 1.2192 m) ST-3 A5067 Replacement power board(without relay). A5060 Replacement power board(with relay). 4 to 8 feet(1.2192 to 2.4384 m) ST-5 8 to 12 feet(2.4384 to 3.6576 m) ST 10 *NOTE: Inlet tube is required and must be purchased separately.Order one inlet tube for each duct smoke detec- tor ordered. Page 2 of 2 — DF-52176 July 14,2004 DF-52004 F-050 T BG-12 Series Fire•LI 1 e®ALarms Manual Fire Alarm Pull Stations www.firelife.com Section: Conventional Initiating Devices State Fire GENERAL , CaliforniaFie ; The Fire•Lite Alarms BG-12 Series is a cost-effective,tea- I I l Marshal ture-packed, non-coded series of manual fire alarm pull `` W, us _F �f; S7150-0075:184 stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series LISTED features a variety of models including single- and dual- action versions. The BG-12 Series provides Fire Lite Fire Alarm Control Panels(FACPs), as well as other manufacturers'controls, 67-02-E with a manual alarm initiating input signal Its innovative APPROVED design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. • Attractive contoured shape with light textured finish. • Meets ADA 5 lb. maximum pull-force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single-or dual-action),yet designed to • prevent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. The word"ACTIVATED"appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. • Operation handle features white arrows showing basic operation direction, for non-English-speaking persons • Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. • Terminal numbers are molded into the backplate, elimi- nating the need for labels. • Station can be opened for inspection and maintenance Switch contacts are normally open. without initiating an alarm. • Product ID label viewable by simply opening the cover; • Can be surface (with SB-I/0 or SB-10) or semi-flush label is made of a durable long-life material. mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. The words "NORMAL" and "ACTIVATED" are molded •into the plastic adjacent to the alarm switch (located in- Back late is large enough to overlap a single-gang backbox cutout by up to 11/2" (12.7 mm). side). • Four-position terminal strip molded into backplate. • Optional trim ring (BG-TR). • Terminal strip includes Phillips combination-head cap • Spanish version (FUEGO) available (BG-12LSP). tive 8/32 screws for easy connection to Initiating Device Designed to replace the Fire•Lite Legacy BG-10 Series. Circuit (IDC). • Models packaged in attractive, clear plastic (PVC), • Terminal screws backed-out at factory and shipped ready clamshell-style, Point-of-Purchase packages. Packag- to accept field wiring (up to 12 AWG/3.25 mm7). ing includes a cutaway dust/paint cover in shape of pull station. Tire d is Alarms is a Honeywell company. ISO 9001 This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate. We cannot cover all specific �a applications or anticipate all requirements. All specifications are subject to '��, change without notice. ENCINEutlr &MANIIFACTIIRIIIC For more information, contact Fire-Lite Alarms, One Fire-Cite Place, Northford, QUALITY SYSTEMS Connecticut 06472. Phone: (800) 627-3473. Toll-Free FAX: (877) 699-4105 DF-52004-07/14/04 — Page 1 of 2 CONSTRUCTION; ties Act(ADA)or per national/local requirements. Manual Cover, backplate and operation handle are all molded Stations shall be Underwriters Laboratories listed. of durable polycarbonate material. *NOTE: The words"FIRE/FUEGO"on the BG-12LSP shall ap- Cover features white lettering and trim, pear on the front of the station in white letters.approximately 3/ 4"hi h. Red color matches System Sensor's popular 9 SpectrAlert'T horn/strobe series. PRODUCT LINE INFORMATION OPERATION Model Description The BG-12 manual pull stations provide a textured finger- BG-12S Single-action pull station with pigtail connec- hold area that includes Braille text. In addition to PUSH tions, hex lock. IN and PULL DOWN text,there are arrows indicating how BG-12SL Same as BG-12S with key lock. to operate the station, provided for non-English-speaking persons. BG-12 Dual-action pull station with SPST N/O Pushing in and then pulling down on the handle activates switch,screw terminal connections,hex lock. the normally-open alarm switch. Once latched in the down BG-12L Same as BG-12 with key lock. position, the word "ACTIVATED" appears at the top in BG-12LSP Same as BG-12L with English/Spanish bright yellow, with a portion of the handle protruding at (FIREIFUEGO) labeling. the bottom as a visible flag. Resetting the station is simple insert the key or hex (model dependent), twist one quar- BG-12LOB Same as BG-12L with Includes outdoor listed backbox, and "outdoor seal- ter-turn then open the station's front cover, causing the spring-loaded operation handle to return to its original in g gasket. position. The alarm switch can then be reset to its normal BG-121O Same as BG-12L with "outdoor use" listing. (non-alarm) position manually(by hand)or by closing the Does not include backbox. station's front cover,which automatically resets the switch. BG-12LA Same as BG-12L with auxiliary contacts. SPECIFICATIONS BG-12LPS Same as BG-12L with presignal feature. Physical Specifications: BG-12LPSP Same as BG-12LPS with English/Spanish (FIRE/FUEGO) labeling. on®0m000 00-O0 00-10 000 000 SB-1/0 Indoor/outdoor backbox. SB-10 Indoor use backbox. 0 am0e X00 LIJ o I®0 s.��mmn 1,.0 p AID 4.21,�n00 , EL) (X14.23 EL 13.91 LAG) (15.24 00) ?9 001 WP-10 Outdoor use backbox. u mm: 1mW00 4.222®ain 4.n)ROnE 4.690 '1.2s®0m0 WBB Outdoor use backbox. o.4r001 (io.izm) ci0.4 001 n°.Q:m1 rU790]) 17003 Key lock- , ®00 4_,3®0100 :_i�5 min 2.0®m00 1 ;5®om0 17007 Hex lock. n00m_ 1 _,i0o> 1 .66m� 12.n_,00� rosCol 14.44500 s2oghl 1 bi 1.390" Electrical Specifications: (35.306) Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. Wire Length ENGINEERS' & ARCHITECTS' Strip Gauge SPECIFICATIONS Manual Fire Alarm Stations shall be non-code,with akey- or hex-operated reset lock in order that they may be tested, I 1.000' (25.40) and so designed that after actual Emergency Operation, be restored to normal except by use of a key or }_ they cannot hex. An operated station shall automatically condition it- I self so as to be visually detected as activated. Manual C J stations shall be constructed of red colored LEXAN® (or 0.750" polycarbonate equivalent)with clearly visible operating in- (19.05) structions provided on the cover. The word FIRE shall ap- I 5.500" pear on the front of the stations in white letters, 1.00 inches (139.70) (254 mm) or larger.* Stations shall be suitable for sur- 9 face mounting on matching backbox SB-10; or semi-flush (mm) mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- E Page 2 of 2 — DF-52004•07!14/04 July 14,2004 DF-52121 • E-325 Fire•LITe°ALarms MMF-300(A) Series/MDF-300 Addressable Monitor Modules www.firelite.coin Section: Addressable Devices GENERAL California Four different monitor modules are available for Fire-Lite ;� t , State Fire Alarm's MS-9200, MS-9200UD and MS-9600 intelligent fire Marshal alarm control panels to suit a variety of applications. Moni- 7300-0075:185 U ;, FM *.or modules are used to supervise a circuit of dry-contact - — input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke A I ' detectors (MMF-302). LISTED UDC APPRQVEQ MMF-300 (Replaces M300) —The MMF-300 Mani- tor Module is a standard-sized module(typically mounts to a CSXXXX 4" [101.6 mm]square box)that supervises either a Class A (Style D)or Class B (Style B) circuit of dry-contact input de- uUAC-M's vices- <._ MMF-301 (Replaces M301)—The MMF-301 is a Min- iature Monitor Module (a mere 1 3" (33.02 mm) H x 2 75" (69 85 mm) W x 0.5" (12.70 mm) D) used to supervise a O Class B (Style B) circuit. Its compact design allows the MMF-301 to be mounted in a single-gang box behind the iS device it is monitoring. MMF-302 (Replaces M302) — The MMF-302 Inter- face Module is a standard-sized module used to monitor and supervise compatible two wire 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 (New) —The MDF-300 Dual Monitor Module is a standard-sized module (typically mounts to a 4" [101.6 mm] square box) that supervises two Class B (Style B) cir- cuits of dry-contact input devices. MMF-300 MONITOR MODULE MDF-300 Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Device Circuit. A 47K ohm End-of-Line Resistor (provided) Powered directly by two-wire SLC loop. No additional terminates the Style B circuit. No resistor is required for power required. supervision of the Style D circuit. Maximum IDC resistance • High noise (EMF/RFI) immunity is 1,500 ohms. SEMS screws with clamping plates for ease of wiring. MMF-300 Operation — Each MMF-300 uses one of Direct Decade 01 — 99 (MS-9200 and MS-9200OD) and 99 (MS-9200 and MS-92000D) or 159 (MS-9600) avail- 01-159 (MS-9600) entry o₹ address, able module addresses on an SLC loop. It responds to LFD flashes red during normal operation and latches regular polls from the control panel and reports its type on steady to indicate alarm and the status (open/normal/short) of its Initiating Device The MMF-300 Monitor Module is intended for use in intel- Circuit (IDC). A flashing LED indicates that the module is ligent, two-wire systems, where the individual address of in communication with the control panel The LED latches each module is selected using the built-in rotary switches, steady on alarm (subject to current limitations on the loop). It provides either a two-wire or four-wire Class A or Class MMF-300 Specifications B fault-tolerant Initiating Device Circuit (IDC) for normally- Nominal operating voltage: 15 to 32 VDC. open-contact fire alarm and supervisory devices. The MMF- 300 can be used to replace M300 modules in existing sys Maximum current draw: 5.1 mA (LED on). terns. Average operating current: 400 pA (LED flashing). MMF-300 Applications — Use to monitor a zone of EOL resistance: 47K ohms. four-wire smoke detectors, manual fire alarm pull stations, Temperature range: 32"F to 120°F (0°C to 49°C). waterflow devices, or other normally-open dry-contact alarm Humidity range: 10% to 93% noncondensing. activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm)wide x tion at the control panel. Monitored circuit may be wired as 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square an NFPA Style B (Class B) or Style D (Class D) Initiating x 2.125" (53.975 mm) deep box. Fire-Lite® nrms io a Honeywell company- '�O 9r0�0 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all �T requirements. All specifications arc subject to change without notice. I I=41 ENhINIfIGM:BMMUfNCN�IPC For more information, contact Fire•Lite Alarms. One Fire-Lite Place, Northford, Connecticut 06472. QUA 11 T Y SYSTEMS Phone: (800) 627-3473, Toli-Free FAX. (877) 699-4105_ DF-52121 -07/14/04 — Page 1 of 3 MMF-301 ,MINI MONITOR MODULE MMF-302 INTERFACE MODULE Built-in type identification automatically identifies this Supports compatible two-wire smoke detectors. device as a monitor module to the MS-9200. MS- Supervises IDC wiring and connection of external power 9200OD or MS-9600. source (resettable). •.Powered directly by two-wire SLC Loop. No additional High noise (EMF/RFI) immunity. power required. • SEMS screws with clamping plates for ease of wiring. • High noise (EMF/RFI) immunity. • Direct-dial entry of address (01-99 for MS-92001MS- • nned stripped leads for ease of wiring. 9200OD 01-159 for MS-9600). • Direct dial entry of address (01-99 for MS-9200/MS- • LED flashes during normal operation. 92000D, 01-159 for MS-9600). - LED latches steady to indicate alarm on command from The MMF-301 Mini Monitor Module can he installed in a control panel. single-gang junction directly behind the monitored unit. Its The MMF-302 Interface Module is intended for use in intel- small size and light weight allow it to be installed without ligent, addressable systems, where the individual address rigid mounting. The MMF-301 is intended for use in intelli- of each module is selected using built-in rotary switches. gent, two-wire systems where the individual address of This module allows intelligent panels to interface and moni- each module is selected using rotary switches It provides tor two-wire conventional smoke detectors. It transmits the a two-wire initiating device circuit for normally-open-con- status (normal, open, or alarm) of one full zone of conven- tact fire alarm and security devices. The MMF-301 can be tional detectors back to the control panel. All two-wire de- used to replace M301 module in existing systems tectors being monitored must be UL compatible with the module. 1415 Pi i ADDRESS o 1 MMF-302 Applications—Use the MMF-302 to moni- 13 2 L - 2 for a zone of two-wire smoke detectors. The monitored cir- i2 ���� ,g, ',; 4 cult may be wired as an NFPA Style B (Class B) or Style D 1 - �4', LOOP (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line 10 5 Resistor (provided) terminates the end of the Style B or D 9 8 6 J 9 8 � 6 (class B or A) circuit (maximum IDC loop resistance is 25 TENS ONES r � ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 Operation — Each MMF-302 uses one of 159 available module addresses on a MS-9600 SLC loop. It uses one of 99 on a MS-9200 or MS-9200OD_ It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC) A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). L MMF-302 Specifications Nominal operating voltage: 15 to 32 VDC. MMF-301 Applications — Use to monitor a single Maximum current draw: 5.1 mA (LED on). device or a zone of four-wire smoke detectors, manual fire Average operating current: 270 pA (LED flashing). alarm pull stations,waterflow devices,or other normally-open EOL resistance: 3.9K ohms. dry-contact devices May also be used to monitor normally- open supervisory devices with special supervisory indica- External supply voltage (between Terminals T3 and T4): tion at the control panel. Monitored circuit/device is wired DC voltage: 18 to 28 volts power limited. Ripple voltage: as an NFPA Style B(Class B)Initiating Device Circuit.A 47K 0.1 VRMs maximum. Current:90 mA per module maximum. ohm End-of-Line Resistor (provided)terminates the circuit. Requires regulated, resettable 24 VDC power. MMF-301 Operation — Each MMF-301 uses one of Temperature range: 32°F to 120°F (0"C to 49°C). 159 available module addresses on an SLC loop MS- Humidity range: 10% to 93% noncondensing. 9600. It uses one of 99 on a MS-9200 or MS-920000. It responds Dimensions: 4.5" e1 .3 mm) high x 4" (101-6 mm)wide x to regular polls from the control panel and re- 1.25" (31.75 mm) deep. Mounts to a 4° (101 6 mm) square ports its type and the status (open/normal/short) of its Ini- x 2.125" (53.975 mm) deep box. t!ating Device Circuit (IDC). MMF-301 Specifications MDF-300 DUAL MONITOR MODULE Nominal operating voltage: 15 to 32 VDC. - Built-in type identification automatically identifies this de- Average operating current: 375 pA maximum vice as two monitor modules to the control panel. EOL resistance: 47K ohms. Powered directly by the two-wire SLC loop. No addi- tional power required. Temperature range: 32°F to 120°F (0°C to 49°C). • High noise (EMF/RFI) immunity. Humidity range: 10% to 93% noncondensing. SEMS screws with clamping plates for ease of wiring. Dimensions: 1.3"(33.02 mm)high x2.75"(69.85 mm)wide • Direct-dial entry of address (01 — 159 on the MS-9600.. x 0.5" (12 70 mm) deep. 01-99 for MS-9200/MS-9200OD). Wire length: 6" (152.4 mm) minimum. • LED flashes red during normal operation and latches on steady red to indicate alarm. Page 2 of 3 — DF-52121 •37/14/04 The MDF-300 Dual Monitor Module is intended for use in ordinances and regulations. intelligent, fwd-wire systems; where the individual adotsy ARCHITECTS'/ENGINEERS' of each module is selected using the built-inotary switches. It provides two independant two-wire fault-toler- SPECIFICATIONS ant Initiating Device Circuits (lDCs) at two separate, con- Specifications of these and all Fire•Lite Alarms products secutivt addresses. It is capable of monitoring normally are available from Fire-Lite Alarms. open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- PRODUCT LINE INFORMATION plications. MMF-300 Monitor Module. MDF-3OO Applications - Use to monitor a zone of MMF-300(A) Monitor Module (Canada). four-wire smoke detectors, manual fire alarm pull sta- tions waterflow devices, or other normally-open dry-con- MMF-301 Mini Monitor Module. tact alarm activation devices. May also be used to monitor MMF-301(A) Mini Monitor Module (Canada). normally-open supervisory devices with special supervi- MMF-302 Two-Wire Detector Monitor Module. sory indication at the control panel. Monitored circuit may MMF-302 A Two-Wire Detector Monitor Module(Canada). be wired as an NFPA Style B (Class B) Initiating Device ( ) Circuit- The 47K ohm End-of-Line Resistors (provided) MDF-300 Dual Monitor Module. terminate the Style B circuit. Maximum IDC resistance is SMB500 Optional Surface-Mount Backbox. 1.500 ohms. MOF-300 Operation - Each MDF-300 uses two of 99 MOUNTING DIAGRAM (MS-9200 or MS-9200UO) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular for standard-sized modules polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in com- munication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MDF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA(LED on). Average operating current: 750 µA (LED flashing). i EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 Ohms. A i ` �; Temperature range: 32°F to 120°F (0'C to 49"C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5'(114.3 mm) high x 4"(101.6 mm)wide x r 1.25'(31.75 mm)deep. Mounts to a 4" (101.6 mm)square x 2.125" (53.975 mm) deep box Cl Accessories: SMB500 electrical box. f �' INSTALLATION t � � MMF-300, MMF-302 and MDF-300 modules mount di- � 1 rectly to a standard 4" (101.6 mm) square, 2.125" (53.975 15 mm) deep electrical box They may also be mounted to � ' the SMBS00 surface-mount box_ Mounting hardware and , ' � installation instructions are provided with each module. All wiring must conform to applicable local codes, ordi- nances, and regulations. These modules are intended for power-limited wiring only. .; The MMF-301 module is intended to be wired and i mounted without rigid connections inside a standard elec 7 l - �) trical box_All wiring must conform to applicable local codes, � ����� ,� �; �c irlf?� I DF-52121 -07114/04 — Page 3 of 3 September 28,2001 DF-52130 E-350 CMF and CRF Series • Ff re-LITe5 AL,arms Addressable Control and Relay Modules www.firelite.com Section: Addressable Devices GENERAL CMF-300 Control Module (Replaces C304) The CMF-300 Addressable Control Module provides Fire•Lite Alarm's MS-9200 and MS-9600 intelligent control Approved panels a supervised Class B (Style Y) or Class A (Style Z) F,„,Via' circuit for Notification Appliances (horns, strobes, etc.). Sfevice 7300-0075185 Addressability allows the CMF to be activated, either manu- ally or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 configured as a relay) CON IROL The CRF-300 Addressable Relay Module provides the MS-9200 and MS-9600 systems with two isolated sets of Form-C dry-contact outputs for activating a variety of auxil- iary devices, such as fans, dampers, door holders, con- trol equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel program- _ ' ming, on a select basis. �� xs�r FEATURES - Built-in type identification automatically identifies these � r ' devices to the control panel. ' - Internal circuitry and relay powered directly by two-wire SLC loop. The CMF module requires power (for horns, . '. b b — F LL strobes,etc.). " � O • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. CMF-300 and CRF-300 Module - High noise immunity (EMF/RFI). • The CMF may be used to switch 24-volt NAC power. OPERATION - Wide viewing angle of LED. Each CMF or CRF uses one of 99(MS-9200) or 159 (MS- - SEMS screws with clamping plates for wiring ease. 9600) possible module addresses on a SLC loop. It re- - Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) sponds to regular polls from the control panel and reports entry of address. its type and status, including the open/normal/short sta- APPLICATIONS tus of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates The CMF is used to switch 24 VDC audible/visual power. its internal relay. The CMF supervises Class B (Style Y)or The CRF [nay be programmed to operate dry contacts for Class A (Style Z) notification or control circuits. door holders, Air Handling Unit shutdown, etc. Upon code command from the panel, the CMF will discon- CONSTRUCTION nect the supervision and connect the external power sup- • The face plate is made of off-white Noryl®. ply in the proper polarity across the load device The dis- connection of the supervision provides a positive indica- • Controls include two rotary switches for direct-dial entry tion to the panel that the control relay actually turned ON. of address (01-99 on the MS-9200 and 01-159 on the The external power supply is always relay isolated from MS-9600) the communication loop so that a trouble condition on the • The CMF is configured for a single Class B (Style Y) or external power supply will never interfere with the rest of Class A (Style Z) Notification Appliance Circuit. the system. • The CRF provides two Form-C dry contacts that switch Rotary switches set a unique address for each module. together. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module Noryl@ is a registered trademark of GE Plastics, a subsidiary of to the control panel, so as to differentiate between a mod- General Electric Company. ule and a sensor address. ' I This document is not intended to be used for installation purposes. We try to keep '�O �0�� This document Is [lot intended to be used for installation purposes. We try to keep Our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements_ All specifications are subject to change without notice. For more information, contact f=ire-Lice Alarms, One Fire-Lite Place, Northford. Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699- ENGINEERING&MANUFACTIBIN6 Made in the URS.A. 4105. FAX Back:(888) 388-3299. DF-52130— Page 1 of 2 SPECIFICATIONS FOR CMF RELAY CONTACT RATINGS Normal operating voltage: 15 to 32 VDC. for both CMF and CRF models Maximum current draw: 5.1 mA (LED on). Load Description Application Maximum Current Average operating current: 390 pA (LED flashing). Voltage Rating External supply voltage (between Terminals 13 and T4): Resistive Non-Coded 30 VDC 3.0 A maximum 80 volts (RMS or DC). Resistive Coded 30 VDC 2.0 A Drain on external supply: 2 mA maximum (using internal Resistive Non-Coded 110 VDC 0.9 A EOL relay). Resistive Non Coded 125 VAC 0.9 A EOL resistance: 47K ohms. Inductive(L/R=5 ms) Coded 30 VDC 0.5 A Temperature range: 32°F to 120°F (0°C to 49°C). Inductive(LJR=2 ms) Coded 30 VDC 1-0 A Humidity range: 10%to 93% non-condensing. kxluctive(PF=0.35) Non-Coded Ii.25 VAC 0.5 A Dimensions: 4.5" (114.3 mm)high x 4" (101.6 mm)wide x c, .1e1b 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53-975 mm) deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25"(31.75 mm)deep. Mounts to a 4" (101.6 mm)square x 2.125" (53.975 mm)deep box. PRODUCT LINE INFORMATION CMF-300 Intelligent Addressable Control Module. CRF-300 Intelligent Addressable Relay Module. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier — required by UL for separating power-limited and non-power lim- ited wiring in the same junction box as . _ �,�j CMF-300. e MOUNTING DIAGRAMS Note O8500 Module Barrier, which creates isolated quadrant. CB500 ISOLATED _ z. QUADRANT 4"(101.6 mm)square x 2.125"(53.975 mm)deep box Page 2 of 2 — DF-52130 t • • • R 1A � � - II _ Modeis Available — — — SC241575W PC2475W., ' -, SC2415W SC2415 SC241575W SC241575 SC2430W 502430 «* SC2475W SC2475 SC2495W SC2495 "'` ' SC24115W 3024115 .• SC24177W 5024177 PC2415VV PC2415 PC241575W PC241575 PC2430W PC2430 ' PC2475W PC2475 l?'x PC2495W PC2495 PC24115W PC24115 PC24177W PC24177 : :' t � BBSCW BBSC Product Overview fib, Like the original SpectrAlert, the SpectrAlert ceding mount series offer sa;.;nificant current draw reductions over other ceiling mount strobes and horn/strobes. SpectrAlert's compact design also offers installation savings. The strobe and horn/strobe models mount to a 4"x4'x1;'"back box, and take up little room in the hack box, making connections easier. And with SpcetrAlert's round shape, it is not necessary to align the back box with the room's walls. SpectrAlert always lines up. SpcctrAlcrt ceiling mount strobes and horn/strobes arc available in - seven different candelas, including 177 candela for sleeping areas. The horn/ strobe's tones are field-selectable through the use of a three position switch located on the hack of the unit- Selections include electromechanical and 3 KT lz tones, temporal and non-temporal patterns, and high and low volume. SpectrAlert ceiling strobes and horn/strobes offer a design that is sensi- tive to the aesthetic demands of ceiling mount applications.The round shape main- tains a ', si profile appearance, similar to that of a smoke detector and provides (�� Fne �MEA clear ly visible "FTR1." identification from all angles. 3Ui16SeP I qa 50.5 _{.v 70, Engineering Specifications --- Srrohe shall he a System Sensor SpectrAlert Model listed to UL 1971 and he approved for fire protective ser- vies where ceiling mount strobes are permitted. The strobe shall be wired as a primary signaling notification appliance and sh ll (lash ;r IT Ta over the strobe's entire operating range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. i-ion a/strol e shall he a System Sensor SpcctrAlcrt Model listed to UL 1971 and UL 464 and be approved for brc protect ve service where ceiling mount horn/strobes arc permitted- The horn/strobe shall be wired as a pr-imarv' n ahng irotification .ippliancc and shall flash ;at 1 Hz over its entire operating range. The strobe light shall consist of a tenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options, and the option to switch between a temporal and a non-temporal continuous pattern. These options shall be selected by a iidti-position switch. Strobes shall he powered independently of the sounder with the removal of factory installed jump- Cr wires. The horn on horn/strobe models shall operate on a coded or non-coded power supply. , otc: l he strobes must be powered continuously for the horn to operate. General Specifications 6.3" diameter 32°to 120° F (0°to 49°C) 5.3 oz. (150 grams) 4'x 4"x 1'/-" back box or 4"x 4x 28'" back box (with skirt) SpectrAlert Mounting Diagrams• 4x4x2'/." BBSCW Strobe or Horn/Strobe with Mounting Plate Strobe or Horn/Strobe with Accessory Back Box Skirt Electrical Specifications --- 24 VDC and FWR unfiltered 16-33 V 6.049,446 — 6,057.778 —.— D424,465 12 to 18 AWb 17-33 V ,ill\tiati ha:l il'yd It WR) voltage is a non-regulated,limo-varying power source that is used on some power supply and panel outputs. the MDL causes a one volt voltage drop in the notification appliance circuit. Table 1-A: SpectrAlert Strobe UL Max. Current Draw(mA RMS) Table 1-B: Horn UL Max.Current Draw Measurements(mA RMS) t Low Electromechanical 23 73 — _ Volume 3000 fir Interrupted 33 23 High 17ecuomechanical I 53 4' 15/75 j 77 78 volume 3000 1-lz Interrupted 57 t 40 30 107 113 __.. _ _-- - Iow Fleet romechanieal 37 29 ----- _. 7 197 I 205 > Volume 3000 Hz Interrupted 32 33 95 239 274 _—. — High Electromechanical — 49 49 115 298 325 volume 3000 Hz Interrupted 56 I s.s -. - 177 399 Table 1-C: 24V DC Horn/Strobe UL Max. Current Draw Measurements(mA RMS) iEIii 76 7R 75 13 75 89 89 91 92 89 90 96 I 1.26 125 1 128 128 t5hll 134 0 22 222 I 222 222 219 219 221_ --- 9, 272 270 271 271 266 265 269 270 1.1 1. 297 291 296 296. 291 290 293--- 1-r7 512 504 i 501 496 491 493 496 Explanation of Published Voltage, Current, and SPL Specifications In May 2004 Underwriters Laboratories changed standard During May 2004, UL also changed the way they list the M. 1971 to require that operating current measuremments voltage range of a device. All 12V products will be listed are made using RMS (root mean square) instead of peak between 8 - 17.5V and all 24V products will he listed it average values. RMS measurements more accurately between 16 — 33V. Those devices are considered "regulat- predict the power consumption of a device since they take ed". Any product that does not operate within these ranges into account the entire current draw profile including surge, will be listed as a "special application" with its operating repetitive surge, and peak values. 1'he published RMS cur- voltage specified on the device. rent is tthe maximum operating current of that device within its operating voltage range. This current maximum may or Notes may not occur at the endpoints of the voltage range. 1. Current draw for strobe-only products is shown in Table 1 A Similarly, ut. tests the audibility of devices in accordance 2- 24VDC 2-wire horn/strobe current draw is shown in Table with tJL 464 by measuring them across the operating volt 1-C. Jge range to determine the minimum sound pressure level 3- Current draw for other horn/strobe power supplies can be produced at any particular selling_ calculated by adding the strobe current in Table 1-A to the horn current in Table 1-B from the chosen settings. Horn Sound Measurements (dBA) SpectrAlert Dimensions 27 — + Lo'Volume Electromechanical 75 3000 Hz interrupted 15 • L 00 W Interrupted �— 81 Hi,ij VOkiRIC Electromechanu-il I�w Volume I L,ectromechanwal 79 _— 13000 Hr interrupted �_. Liwi)Volume Electromechanical - 84 3000 Ha Interrupted 86 SpectrAlert Ceiling Mount Strobe 22— I 8'fl_ I -- SpectrAlert Ceiling Mount Horn/Strobe Ordering Information PC241575W Ceiling-mount horn/strobe. 24 volt, 15/75 candela. — — white SC2115 Ceiling-mount strobe. 24 volt. 15 candela, red - - -- -- — PC2430 Ceiling-mount horn/strobe, 24 volt, 30 candela. red SC2415W Ceiling mount strobe. 24 volt. 15 candela white ---�-- -- -- PC2430W Ceiling-mount horn/strobe: 24 volt. 30 candela, white aSC2 i`rr'5 Ceiling mount strobe, 24 volt, 15/75 candela. red — — — — — PC2475 Ceiling mount horn/strobe, 24 volt, 75 candela. red SC241575W Ceiling mount strobe. 24 volt. 15/75 candela,white -- j—_. --- -- — PC2475W Ceiling-mount horn/strobe,24 volt, 75 candela,white 5C2430 Ceiling-mount strobe. 24 volt. 30 candela, red PC2495 Ceiling-mount horn/strobe, 24 volt, 95 candela. red SC2430W Ceiling mount strobe, 24 volt, 30 candela,white — — — 1— --- — — PC2495W Ceiling mount horn/strobe, 24 volt, 95 candela.white 502475 Ceiling mount strobe, 24 volt. 75 candela, red — — — PC24115 Ceiling-mount horn/strobe, 24 volt, 115 candela, red SC1475W Ceiling-mount strobe, 24 volt. 75 candela,white — - - - + -- -- --- —-- — -- PC24115W Ceiling mount horn/strobe, 24 volt, 115 candela. SC2495 Ceiling mount strobe. 24 volt,95 candela, red white SC2495W' ; Ceding mount strobe, 24 volt, 95 candela white PC24177 Ceiling-mount horn/strobe, 24 volt, 177 candela. red SC24 15 J Ceiling-mount strobe, 24 volt. 115 candela. red PC24177W Ceiling mount horn/strobe, 24 volt, 177 candela. SC24115W I Ceiling-mount strobe. 24 volt, 115 candela.white white $62.177 Gelling mount strobe, 24 volt, 3.77 candela. red ' — SC24177W I Ceiling mount strobe, 24 volt. 177 candela.white MDL _ Syne-Circuit " Module, red 062415 Ceiling rrount horn/strobe, 24 volt, 15 candela, red MDLW Sync•Circud1' Module,white PC2415W Ceiling-mount horn/Strobe, 24 volt. 15 candela. white BBSC Surface mount back box skirt red �— BBSCW Surface-mount back box skirt,white 06241575 Ceiling-mount horn/strobe.24 volt,15/75 candela,red System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor-Far East System Sensor-India 3825 Ohio Avenue Ph 905.8120767 Ph-86.29.8832.0119 Pb.85.22.191.9003 Ph:91.124 231 3770 x.2700 St.Charles. 'i 603.74 lx:905.812.0771 Fx-86.29.8832.5119 Fx:85.22.736.6580 Fx:91-124.237.3118 Ph: 800/SENSOR.' System Sensor Europe System Sensor in Singapore System Sensor—Australia System Sensor-Russia Gs:53 ' 5//6495 Ph-44.1403.276500 Ph:65.6273.2230 Ph:613.54.281.142 Ph:70.95.9377982 wwwsysiem,en.or.cO,t Fx: 44.1403.276501 Fx:6h.6273.2610 Ex:613.54 283.172 Fx 70.95.93/ 7983 mPany A05-1025-008.9/05•N1,10 rr�_ ;-�,r Sc,.Th te«rvcti tier To Ch�1 , rrodVct�I�rr.(r,anon;�v hoot notici- I • 1 1 II - Models Available no �i '"""^+• P1224MC Horn/Strobe Red White r, S1.224MC S1224MCW 3 S1224MCP S1224MCPW S1224MCK S1224MCSP Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK � P1224MCSP Red White H12/24 H12/24W H12/24K Product Overview t§. t a l iu ;ut eerca, fJ'Cc - ccs x :.gam tt Jt..zc,•>t ✓ ..tte.)0f�, �,it ia, l . i'es, i. .,.. T .. ,.� tic:.�..e: ,_.`_ tl...,..). ,9_... 'rr'. ..I :z t'r: ..7 - .".: 3:. `321; p�e.ar,. .,r _=a .;, 1�,�, ,n�,� '.c ,- or _zap. ef..r 1],t a, kv € Si.,.... "t SpectrAlert selectable output wall-mount horns,strobes, and horn/strobes tt offer key performance features long associated with the SpectrAlert name_The select able candela strobes and horn/strobes offer average current draws that arc not only lower than conventional fixed-candela SpectrAlert products,but also lower than similar selectable candela products. By consuming less current,the ability to connect even more devices per loop is possible, resulting in a lower installed cost. SpectrAlert selectable output horns,strobes,and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name,such as the option of 2-and 4-wire operation; the ability to use standard sire backboxcs with no encroachment into the box; and universal mounting incorporating the labor-saving All strobe and horn/strobe models incorporate a (�tuc (.lie< k I T" feature. Such labor-savings features make wire connections simple and fast, new patent-pending voltage booster design that has a more consistent flash bulb voltage over further reducing installed cost. -- �<< SpectrAlcrt selectable output strobes and horn/strobes offer the broadest the range of candela selections. The benefit to the customer is a high quality strobe device. range of candela options_In addition,the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options UL ��� continue to be available, in either an Electromechanical or 3kHz pattern_ LISTED 5'.4'Iy002NK1/504 SpectrAlert selectable output horns,strobes,and horn/strobes incorporate .4 ]0JNKl i]':1 4m1 the same stylish, low profile design of the conventional SpectrAlert products, for a con- FM MEA sistcnt and aesthetically pleasing appearance across the entire product line_ approved 11:'.1)04 222 .vvaweo 122-021. 7775-7)04:) 0J7-1!:)) 17&07-F Engineering Specifications — — fire protective service.Horn/strobe shall be wired as a primary SpectrAlert horns,strobes and horn/strobes shall he capable of signaling notification appliance and comply with the Americans nuwnting to a standard 4" x 4" x 1 /z" back box or a single gang with Disabilities Act requirements for visible signaling appliances, 2' x 4" I'/x" hark box using the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage range. included with each SpectrAlert product. Also, SpcctrAlert prod- The strobe light shall consist of a xenon flash tube and associated us:s, when used in conjunction with the accessory Syne`Circuit lens/reflector system- The hoop shall have two tone options, two Module, shall be powered from a non-coded power supply audibility options (at 24 volts) and the option to switch between and shall operate on 12 or 24 volts. 12 volt rated devices shall a temporal 3 pattern and a non-temporal continuous pattern. havean operating voltage range of 9-17-S volts. 24-volt rated Strobes shall be powered independently of the sounder with the devices shall have an operating voltage range or 17-33 volts, removal of factory installed jumper wires.The horn on horn/ SpectrAlert products shall have an operating temperature of strobe models shall operate on a coded or non-coded power sup- 32° to 120°F and operate from a regulated DC or full wave ply (the strobe must be powered continuously). rectified, unfiltered power supple- -., = s .,nEJ{B r.;2 ,e, r tea Module shall he a System Sensor Sync•Circuit listed Strobe shall he a Svstem Sensor SpcctrAlert Model to UL 464 and shall he approved for fire protective service The listed to tit. 1971 and be approved for fire protective service.The module shall synchronize SpcctrAlert strobes at I Hz and horns strobe shall be wired as a primary signaling notification appliance at temporal 3. Also, the module shall silence the horns on horn/ and comply with the Americans with Disabilities Act require- strobe models, while operating the strobes,over a single parr of meats for visible signaling appliances,flashing at 11Iz over the wires. The module shall be capable of mounting to a 4''/i�" x srrobc's entire operating voltage range-The strobe light shall con- 4'1/,F" x 2'/x" back box and shall control two Style Y (class 8) or sisr of a xenon flash tube and associated lens/reflector system- one Style Z (class A) circuit- Module shall be capable of multiple zone synchronization by daisy chaining rnulciplc modules together and re_synehronizing each other along the chain.The module I torn/Strobe shall be a System Sensor SpcctrAlert Model shall not operate on a coded power supply. listed to UL 1971 and UI.464 and shall he approved for Specifications SpectrAlert horn/strobe and horn only 8.8 oz. 12V: 8-17.5V; 24V: 16-33V work on "walk tests" with time Jura -- Lions of 4 seconds or greater 4" x4 x11// or 2" x 4" x17/8 — — — standard boxes 12V: 9--17.5V; 24V '[7-33V 12 to 18 AWC — *Note for Strobes: Do not exceed: 1) 32°F to 120°F (0°C to 49°C) 16-33 or 8-17.5 voltage range limit; 2) maximum number of 70 strobe lights Strobe and horn strobe with universal when connecling the MDL Sync module plate 95% as tested per UL464 with a maximum line impedance of 4 5" x 5'/a" x 21'/ir -- — ohms per loop and; 3) maximum line Strobe and horn/strobe with small impedance as required by the fire alarm footprint plate Weatherproof(horn and horn/strobes) 32°F to 150°F (0°C to 66°C) control manufacturer 33/x„ x 5-/a" x 2`'/16 _ - Nora with universal mounting plate (outdoor strobe only) 40°I=to 158°F (-40°C to 70°C) 5,593,569 5' x 5'/s" x 1`'/?s" 5,914,665 Horn wnhout mounting plate ULC Canadian Models 40°C to 66°C 6,049,446 215/15" x 5s/1F" 15/1e„ --- 7.2 07 12 or 24VDC and FWR unfiltered SpectrAlert Current Draw —_ ,r S122iMC 15 112 64 727 59 Si robes 1 5/75 135 74 127 69 30 93 90 75 158 160 110 208 45.7 57.5 44.4 57 75 P1224MC 15 112 64 127 59 7� Horn/Strobes lb/75 135 74 1.27 69 45-7 57.5 44.4 57 90 57.5 57 75 30 93 - - 57 75 75 158 160 57.5 _ — 110 57.5 57 75 208 209 — — I 75 H12/24 Horns �� 45.7 57.5 44-4 57 SpectrAlert Mounting and Operation — _- --— — Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the t ;,>e;- t Low Volume j Electromechanical rear of the product while watching the viewing window on the 3000 Hz Interrupted side of the reflector. High Volume Electromechanical — Permissible Candela Settings 3000 Hz Interrupted O- ,ai, Low Volume Electromechanical 3000 Hz Interrupted _ 15 OK OK High Volume Electromechanical l5/7508 OK 3000 Hz Interrupted ?1) OK 75 OK DIP Switch Operation — 5K Factory DIP Switch 11.0 Viewing Window OFF ON Default A0133 00 Low L111 High Temporal / Non Temporal 0 : Electromech- 3000Hz o o Base(rear) AU I'C-00 Typical weatherproof mounting with universal plate Plate WBB #8-36 x 1/2"Flat Head Screw(4 total) 0 Gasket Conduit Entrance —Slot Paper Liner Locking Rib For Plate Gasket SpectrAlert Ordering Information < 6t __L H12/24 Horn, 12/24 volt, red P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt.white H12/24W Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red,weatherproof P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red. --. plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt. MDL Sync•Circuit Module, red white, plain housing MDLW Sync•Circuit Module,white- - - P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red. MDLA Sync•Circuit Module, red, Canadian model weatherproof - P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, MDLWA Sync•Circuit Module,white, Canadian model "FUEGO" housing _ S-MP Small Footprint Mounting Plate, red, for single S1224MC Selectable Output Strobe, 12/24 volt, red gang back box — —_ S1224MCW Selectable Output Strobe, 12/24 volt, white S MPW Small Footprint Mounting Plate,white,for single gang back box 51224MCP Selectable Output Strobe, 12/24 volt, red, plain BBS Surface Mount Back Box Skirt, red h sing --- - Surface Mount Back Box Skirt.white S1224MCPW (Selectable Output Strobe. 12/24 volt,white. BBSW -- -- plain housing D_MP Universal Mounting Plate (replacement), red S1224MCK Selectable Output Strobe, 12/24 volt, red, p_MPW Universal Mounting Plate (replacement). white — weatherproof - -— WBR Weatherproof Back Box S1224MCSP Selectable Output Strobe, 12/24 volt, red, "FUEGO" housing Notes — —. —— Agcncy Listings-Indoor models:Ul.,ULC,FM,CSI-M,Ml'.A Weatherproof models:UL,CSFM (strobe only),MFA,ULC- -ti of these SpcctrAlert products arc designed for wall mount only.All weatherproof models must use weatherproof back box model WI3B-Installation of less tha, 5 candela sirobcs may be pernussihic under the equivalent facilitation clause of the ADAAG (Sec.2 However,it is the responsibility of the person or entity designing the fire alarm sysrem to determine the acceptability of less than 75 candela strobes All 15/75 candela strobes or horn/ strobes arc recommcuded for 20'x 20'rooms or less. System Sensor Sales and ServiceSystem Sensor Headquarters System Sensor Canada System Sensor in China System Sensor-Far East System Sensor-India Ph:86-29.524.62`,3 Ph 85.22.191.9003 Ph:91.124.237.1770 x.2700 3826 Oho Avenue Ph 905.8120767 x: 91.124.237 3118 SL C`tarles.IL 60174 Fr:905.8120711 ix:86-29-524.6269 Fx:85.22-736-6580 Ph.800/St NS0P2 System Sensor Europe System Sensor in Singapore System Sensor—Australia System Sensor—Russia 6.'30'777-6496 Ph:65.6273.22'',0 Ph:613.54.281.142 Ph:70.95.9;7.7982 Ph:44.1403.891920 Fx� 70.95.937.7983 ocumen rn ts- , errand tx: 44.1403.891921 ix: 6.`,_627;.2670 Ix�613 54.281.172 800/7315 7672 x8 www systernsensn,.com 005-032`r003-5!04•N1200 J 9004 System Sensor.The company reserves the right to change product speuocations without notice. ®FIre-LITerALarrns MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Regulated Load in Standby Main Circuit Board 1 x 0.120000 = 0.120000 4XTMF 0 x 0.005000 = 4-Wire Smoke Detectors 1 0 x 0.000000 = Power Supervision Relays 0 x 0.025000 = ANN-80 0 x 0.015000 = ANN-I/O 0 x 0.035000 = ANN-I/O LEDs 0 x 0.000000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.015000 = Addressable Devices BEAM355 and BEAM355S 0 x 0.002000 = BEAM 1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 1 x 0.000300 = 0.000300 SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 6 x 0.000300 = 0.001800 D350RP 0 x 0.000300 = MMF-300 2 x 0.000400 = 0.000800 MMF-300-10 0 x 0.003500 = MDF-300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 5 x 0.000230 = 0.001150 CMF-300 0 x 0.000390 = CMF-300-6 0 x 0.002250 = CRF-300 6 x 0.000270 = 0.001620 CRF-300-6 0 x 0.001450 = 1300 0 x 0.000400 = B501 BH&8501 BHT 0 x 0.001000 = B224RB Relay Base 0 x 0.000500 = B224B1 Isolator Base 0 x 0.000450 = Current Draw from TB3-EIA-485 0.000000 a Total Standby Load 0.125670 Page 1 of 4 Flre•LITeALarms MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only.need tomake entries in the yellow cells Regulated Load in ALARM IIAIjiI ':j!1J;1'1r pii(:iii1jJj ___________ Main Circuit Board 1 x 0.200000 = 0.200000 4XTM F 0 x 0.011000 = 4-Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.000000 = ANN-80 0 x 0.040000 = ANN-I/O 0 x 0.200000 = ANN-I/O LEDs 0 x 0.010000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.075000 ALL Addressable Devices-Maximum draw 1 x 0.400000 = 0.400000 NAC#1 6 x 0.150000 = 0.900000 NAC#2 0 x 0.000000 = Current Draw from TB3-EIA-485 0.000000 = 3Total Alarm Load 1.500000 Notes: 1) If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 2) Current limitations for NAC circuits TB1 is 2.5 amps per circuit 3)Total alarm current cannot exceed 2.7 amps Page 3 of 4 ®FIre-uTe'ALarms MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only geed to•make entries in the yellow cells Calculation in Total Sheet Use the total standby and alarm load currents calculated in tables A-2A and A-2B for the following battery calculations (24 or 60 Hrs. Standby Load Current(Amps) 0.125670 x 24 = 3.016 AH • ii IliilinI:.1uf (5 minutes= 0.084) Alarm Load Current(Amps) 1.500000 I x 0.084 I = 0.126 AH Total Current Load 3.142 AH Multiply by the Derating Factorl 1.2 I = x 1.20 Total Ampere Hours Required 3.770 AH The MS-9050UD can charge this size battery The batteries can be stored in the cabinet NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. MS-9050UD current draw: The required output current is within the panel's limitations Page 4 of 4