08-8622
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8622 FIRE ALARM SYSTEM PERMIT Permit Number: 8622 Address: 38435 5TH AVE HISTORIC Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-15300-0120 lmprov. Cost: 4,975.00 Date Issued: 12/11/2008 Name: PRICE, MARCUS S & MJ Total Fees: 150.00 Address: 38435 5TH AVE -HISTORIC Amount Paid: 150.00 ZEPHYRHILLS, FL. 33542 Date Paid: 12/11/2008 Phone: Work Desc: INSTALL FIRE ALARM SYSTEM COMMERICAL FIRE&COMMUNICATION: FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 n ( [ �la ---11- o� s ( a.r FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE R RDING YOUR NOTICE OF COMMENCEMENT. CONT CTOR SIGNATURE I lC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION -8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 813-780-0020 City of Zephyrhills Permit Application Fax-813-780.0021 ^ BurfdmgQepartrneM jJ Date Received /E3 f PhoneContadforPemnitling 7Z� ,530 U's2( Owners Name �ICC CU& s Q A-kZ3 I Owner Phone Number Owners Address I 3 S -4 3 Owner Phone Number 1 Fee Simple Titleholder Name [A I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS I 38 4 3 S S Nm i $' ILOT# CJ � SUBDIVISION PARCEL ID# Lk-2Co--( -oO(O )53O-)-G i 2O (OBTAI)FD FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEWCONSTR B ADDIALT = SIGN [ J MOVE Q DEMOLISH INSTALL REPAIR PROPOSED USE ED SFR O COMM Q OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME [D STEEL OTHER DESCRIPTION Or WORK l k)STALL ,AJOL) tQ>✓ A1A M S1<STEl1+t BUILDING SIZE I I SO FOOTAGE HEIGHT r®slmoesnreamoplmMom Q BUILDING L_ VALUATION OF TOTAL CONSTRUCTION S AMP SERVICE O PROGRESS ENERGY El WR.E.C. Q PLUMBING MECHANICAL VALUATION OF NECHANICAL INSTALLATION GAS Q ROOFING O SPECIALTY[] OTHER FINISHED FLOOR ELEVATIONS r FLOOD ZONE AREA AYES QNO-- J BUILDER COMPANY -� SIGNATURE REGISTERED I Y/N I FEE CURRENT I Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I YIN FEE CURRENT I Y I N Address Lim# PLUMBER COMPANY L I SIGNATURE REGISTERED I YIN I FEECURRENT I YIN Address License# [ MECHANICAL COMPANY SIGNATURE REGISTERED I YIN I FEECURRENr I YIN Address License# OTHER PANY I°AIMNACrALiL * °�tlulL(U,li(C � SIGNATU REGISTERED Y/N I FEE CURRENT Y I N A (oS t l ?)3 I Tense# R.700o7$5 aunaR RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans:(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(1( working days after submittal date. Required onsite,Construction Plans,Stormwater Plans vd Sint Fence installed, Sanitary Facilities&1 dumpster,Site Wbrk Permit for subdivisionsllarge projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new cons ruction. Minimum ten(10)'working days after submittal date. Required onsde,Construction Plans,Stormwater Plans WI Silt Fence installed, Sanitary Fealties&1 dumpster.Site W ark Permit for at new projects.At commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: axaeosls mm Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required.(AIC upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences(PlarSurveyiFootage) Driveways-Not aver Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to'deed'restrictions' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division--Licensing Section at 727-847- 8009. Furthermore,if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the'contractor Block'of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTAUTIUTIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It Is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a'certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasco County WatertSewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): if valuation of work is$2,500.00 or more,I certify-**t-).-- applicant. have been provided 4. a_wily_.of the_"Florida Gonstrrtriion_LIertlaw--Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the'owner,I certify that I have obtained a copy of the above described document and promise in good faith to deliver It to the'owner'prior to commencement CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the Intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health& Rehabilitative ServiceslEnvironmental Health Unit-Walls,Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency Asbestos abatement - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fit is not allowed in Flood Zone'V unless expressly permitted. - If the fill material is to be used in Flood Zone 'A', it is understood that a drainage plan addressing a "compensating volume'will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone'A in connection with a permitted building using stem wall construction,I certify that fill will be used only to fig the area within the stem wall. - If fill material is to be used in any area. I certify that use of such fill wilt not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the bolding permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs,wells,pools,air conditioning,gas,or other installations not issued shall be construed to be a license tospecifically ��in the cancel,application. A permit proceed with the work and not as authority to violate,cancel,alter,or set aside an y provisions of the technical codes,nor shag issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invaid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and well demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LEND RANATTORNEY BEFORE RECORLI4 YOUR NOflCE OF COMMENCEMENT. ORIDA JJRAT .S 1 OWNER OR A VLLR iviir4 otvy /j/ bsatbed a ( meI1iS ub5afbed and to(a me this p3, Who isiare knave time h e produced who sIare'oe5lly kn a produced ,1 as ider�fication. �(1/ CI_ lf Notary Public `l�/0X1 L c LJ �b r� Ltd Notary Public Conmission No. D 2 mr D50 (8(, Coesson No. lT)IDSO a t 8 Name of Notary typed,prinfed or._stam,_pad Name of Notary typed,printed or stamped sp`*i rAl wiz-i t K-WILLIAMS MY�U!t'viISStON#DD502186 �iAf� '5 tllA aY C'GNi .'SIGN#DD502186 ��orF���� rXPIR;:5: Dec.27,2009 �" (407)398-0153 r'ionda Notary Servlce.com (407)398-0153 ''onda^notary Service corn Zephyrhills Fire Rescue 6907 Dairy Road,Zephyrhills,FL 33542 Fire Marshal Bus(813)780-0041 Kerry Barnett Fax(813)780-0044 E-mail: kbamett@fire.zephyrhills.fl.us Plan Review#: 08-161 Project: Mercantile Occupancy (Marcus Price) Number of Pages: 1 plus spec packet and calcs Date: December 4, 2008 I have reviewed the plans for the fire alarm install located at 38435 5th Avenue allowing this project to move forward. Payment for permit contractor acknowledges agreeing with items below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Installation shall be in compliance with NFPA 72,2007 edition. 2. Relocate smoke detector to hallway in front of bedroom. 3. Install outside strobe 5th Avenue side of building,lower level. 4. Lock off breaker for fire alarm and mark. 5. Label telephone jacks. 6. Date batteries in panel. 7. Change zone for Zone 4 to upstairs apt smoke detector 8. Provide zone map at panel. 9. Provide UL Certificate of monitoring station during acceptance test. 10. Knox box required. Ensure occupant has ordered one. If not application can be obtained from address above. (this will not hold up final approval) 11. Strobes to remain on when system is silenced. Inspections Required: 1. Acceptance Test KERB ARNETT, FIRE MARSHAL *"'Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. FIRE SERVICE USER FEES Occupancy N : Plan No.: Contractor. ( .fi Business Name: 1 Billing Address: a Sic /1) Business Address: 5 Business Phone No.: Billing Phone No.: -7_2 - ?b-- 6S21 S" Z Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE Site Plan N/C Annual N/C Spdnider $50 tat Alarm N/C MWN-FamllipCommeroial .08 of let Re-Inspection N/C Standpipes $50 2nd Alarm N/C (Minkmarr Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C 0 Plan Revisions DBL 3rd Re-inspection $250 Hoods 4th Alarm $100 4th Re-Inspection $500 Fire Alarm 5th Alarm $150 SPRINKLER SYSTEMS (Businnees closed until LP Gas 8th Alarm $200 8 0-25 Heeds $50 violations corrected) Natural Gas $50 nror`a co cumc:E $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 sparders $100 Per Riser $50 Hydrostatic Test $65 per syetam Fire Works $500 FIRE PUMP Acceptance Test $45 per system Camp Fire $25 0 Per Pump $100 Hydrant Flow $75 Conboued Bum $100 ALARM SYSTEM Hood/Duct $50 -25 Devices FIRE ALARM SYSTEM Place of Assembly $50 Annual Z6 plus Devices $100 System Acceptance 0) Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance x Flames A $50 Anna Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wall/Smoke Wall $15 per weU Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 per system Blo-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 0 Hood/Ducts $50 Tent 105c1o'or greeter $15 per tent Torch Pot/AppNed $50 OTHER U Fire Pump $45 Haz.Materials $100 Annual LP Uretallafion per tank $50 U Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) ❑spray Booth $50 9 Inspection scheduled DBL and cancelled less than 24 hours Construction Inep. N/C Emergency Vehicle Ace $50 ,.FALSE ALARM PLANS TOTAL[ :}- INSPECTION TOTAL1 PERMIT TOTAL____ L TOTAL_____ GRAND `TOTAL I_ Comments: Date: lns%ctor. COMMERCIAL FIRE &COMMUNICATIONS INC. P.O. Box 1350 LARGO, FL 33779 (727) 530-4521 FAX (727) 531-0596 License OEF0000785 DATE 2(a JOB NO. (U M ATTENTION WE ARE SENDING YOU ❑ Attached 0 Under separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples C] Specifications ❑ Copy of letter 0 Change order ❑ COPIES DATE NO. DESCRIPTION 3 £QTt E&oe P ' ' __ e7kokLt THESE ARE TRANSMITTED as checked below: For approval El Approved as submitted 0 Resubmit copies for approval 0 For your use ❑ Approved as noted ❑ Submit copies for distribution 0 As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ ❑ FOR BIDS DUE ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: if enclosures are not as noted,kindly notify us at once. Commercial FIRE ® w & Communications,lnc. 6510-B 125th Avenue N. P.O. Box 1350 Phone(727)530-4521 Largo, FL 33773 Largo, FL 33779-1350 Fax(727)531-0596 Goin' Postal 38435 5"' Ave Zephyrhills, FL. Fire Alarm Equipment Submittal Description Manufacturer Part# Control Panel Silent Knight 5208 Smoke Detector System Sensor 2W-B Pull Station FireLite BG-12 Horn-Strobe(Wall) Wheelock ZNS-MCW-FW Bell Wheelock MB-GG6-24-R Lock Box Knox 3200 Series Battery Caics —Voltage Drop SUBMITTED PLAN(S)/HAVE BEEN REVIEWED BY ZEPHYRHILL A 'S OFFICE #10321 Date: Reviewer: 11.26.08 CRM Full Service Alarm&Communications Contractor License#EFOOG0785 Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel • Clock source setting options for 50 • Event History Buffer(150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2- or Specifications 4-wire detectors Operating Voltage: 24 VDC • 8 selectable/programmable output patterns for notification appliance Primary AC: 120 Vrms © 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 24.75"(62.9 cm) • Programmable smoke verification, Width: 14.5"(36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16"(8.73 cm) enhanced verification mode features with 5/8"protruding SK-5208 that can help minimize false alarms Overall Dimensions: • Programmable from the built-in Height: 26-3/8" (67 cm) •control panel touchpad, remote Width: 17-3/16"(43.66 cm) SKSS Downloading Software annunciator, or Windows®SKSS Total Depth: 4" (10.16 cm) • Plex-2 Door Option downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0°to 49°C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) SILENT while providing single button • 7181 Fire Zone Converter KNIGHT operation of the reset and silence • 5220 Direct Connect Module functions • 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator ,► Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect For On-Site Programming 2 Class A(Style D) ,. P'' or Class B (Style B) � Initiation Circuits Programmable Form C Relays 8 Class B (Style B) Notification Initiation Circuits Appliance Circuits 5235 Remote rkh3yyr�,w x r. Y �y°�R gyp ' R�s4o Annunciators t o o SBUS Devices o 0 0 5280, 5217, & 5824 To AC + SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350318 Rev B, 11/05 subject to change without notice. For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone: (800)328-0103, Fax: (763)493-6475. SYSTEM SENSOR Photoelectric Smoke Detectors System Sensor's i3"series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation ease, intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire the bases included with the heads.The large wire entry port and in-line terminals •Large wire entry port provide ample room for neatly routing the wiring inside the base. •In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, •Mounts to octagonal and single-gang backboxes,4-square as well as direct mounting with drywall anchors.To complete the backboxes,or direct to ceiling installation,i3 heads plug in to the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base •Removable detector cover and chamber Intelligence.i3 detectors offer a number of intelligent features •Built-in remote maintenance signaling to simplify testing and maintenance.Drift compensation and smoothing algorithms are standard with the i3 line to minimize Drift compensation and smoothing algorithms nuisance alarms.Two-wire i3 detectors needing cleaning can •Simplified sensitivity measurement generate a remote maintenance signal,when connected to the -Wide angle,dual color LED indication 2W-MOD2 loop test/maintenance module,or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the •Loop testing via EZ Walk feature module and the panel.The SENS-RDR,a wireless device,displays the Built-in test switch sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on two-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings 0 MEA IMFM LISTED approved approved 5911 3011446 7272-1209:210 290-01-E 2093 (j;)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°Q.The detector shall include a mounting base for mounting to 3'k-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel,and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12V,23mA @ 24V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:05 A @ 30V AC/DC Dimensions(including base) 5.3 inches(127 rnm)diameter;2.0 inches(51 mm)height Weight 63 oz.(178 grams) Operating Temperature Range 2W-B and 4W-B:32°F-120°F(0°C-49°C);2WT-B and 4WT-B:32°F-100°F(0°C-37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft.nominal Input Terminals 14-22 AWG Mounting 3'h-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information .. 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12V,23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V,23mA @ 24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 in.(16.76cm)diameter SYSTEM X7006 System Senses. 3825 Ohio Avenue•St.Charles,IL 60174 Pruduc[s{w<ificatian wb�rt[o dungewitlau[nonce.VisR systemsenswcom fp �4 SENSOR Phone:800-SENSOR2•Fax:630-377-6495 A06-O31&006.7/06•/1676 June 10,2005 DF-52004• F-050 • Flre•LITeALarms BG-12 Series by Honeywell Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices GENERAL California The Fire•Lite Alarms BG-12 Series is a cost-effective,lea- Marshal State Fire Marshal ture-packed, non-coded series of manual fire alarm pull C o US 7150-0075:184 stations. It was designed to meet multiple applications with the installer and end-user in mind.The BG-12 Series LISTED features a variety of models including single- and dual- S711 action versions. I•M M EA The BG-12 Series provides Fire•Lite Fire Alarm Control Panels(FACPs), as well as other manufacturers'controls, 67-02-E APPROVED with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, F� -,-� �.--'r..—,--•. and operate. FEATURES • Aesthetically pleasing, highly visible design/color. • Attractive contoured shape with light textured finish. • Meets ADA 5 lb. maximum pull-force. • Meets UL 38,Standard for Manually Actuated Signaling Boxes. • Easily operated (single-or dual-action),yet designed to prevent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. • The word"ACTIVATED"appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. — • Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. • Braille text included in finger-hold area of operation handle and across top of handle. • Multiple hex- and key-lock models available. • U.S. patent-pending hex-lock needs only a quarter-turn • Switch contacts are normally open. to lock/unlock. • Can be surface (with SB-I/O or SB-10) or semi-flush • Station can be opened for inspection and maintenance mounted. Semi-flush mount to a standard single-gang, without initiating an alarm, double-gang, or 4" (10.16 cm)square electrical box. • Product ID label viewable by simply opening the cover; • Backplate is large enough to overlap a single-gang label is made of a durable long-life material. backbox cutout by up to 1/2"(1.27 cm). • The words"NORMAL"and"ACTIVATED"are molded into • Optional trim ring (BG-TR). the plastic adjacent to the alarm switch (located inside). • Spanish version (FUEGO) available (BG-12LSP). • Four-position terminal strip molded into backplate. • Designed to replace the Fire•Lite legacy BG-10 Series. • Terminal strip includes Phillips combination-head cap- • Models packaged in attractive, clear plastic (PVC), tive 8/32 screws for easy connection to Initiating Device clamshell-style, point-of-purchase packages. Packag- Circuit (IDC). ing includes a cutaway dust/paint cover in shape of pull • Terminal screws backed-out at factory and shipped ready station. to accept field wiring(up to 12 AWG/3.1 mm2). Fire•Lite® Alarms, System Sensor®, and SpectrAlert®are • Terminal numbers are molded into the backplate, elimi- registered trademarks of Honeywell International Inc.LEXAN®is nating the need for labels, a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product ISO 9001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENCINEERINC 6 MANUFACTURING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52004•06/10/05 — Page 1 of 2 CONSTRUCTION PRODUCT LINE INFORMATION • Cover, backplate and operation handle are all molded BG-12S Single-action pull station with pigtail connec- of durable polycarbonate material. tions, hex lock. • Cover features white lettering and trim. BG-12SL Same as BG-12S with key lock. • Red color matches System Sensor's popular SpectrAlert® BG-1 2 Dual-action pull station with SPST N/O horn/strobe series. switch,screw terminal connections,hex lock. OPERATION BG-12L Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger- BG-12LSP Same as BG-12L with English/Spanish hold area that includes Braille text. In addition to PUSH IN (FIRE/FUEGO) labeling. and PULL DOWN text,there are arrows indicating how to BG-12LOB Same as BG-12L with "outdoor use" listing. operate the station, provided for non-English-speaking Includes outdoor listed backbox, and seal- persons. ing gasket. Pushing in and then pulling down on the handle activates the normally-open alarm switch.Once latched in the down BG-12LO Same as BG-12L with "outdoor use" listing. position, the word "ACTIVATED" appears at the top in Does not include backbox. bright yellow, with a portion of the handle protruding at BG-12LA Same as BG-12L with auxiliary contacts. the bottom as a visible flag.Resetting the station is simple: BG-12LPS Same as BG-12L with presignal feature. insert the key or hex (model dependent), twist one quar- ter-turn, then open the station's front cover, causing the BG-12LPSP Same as BG-12LPS with English/Spanish spring-loaded operation handle to return to its original (FIRE/FUEGO) labeling. position.The alarm switch can then be reset to its normal SB-I/O Indoor/outdoor backbox. (non-alarm) position manually(by hand)or by closing the station's front cover,which automatically resets the switch. SB-10 Indoor use backbox. 17003 Key lock. SPECIFICATIONS 17007 Hex lock. Physical Specifications: pull station SB-I/O SB-10 Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) (3.66 cm) (3.49 cm) 52004dim.ti Electrical Specifications: 1.390" Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. (33.531,531) ENGINEERS' & ARCHITECTS' SPECIFICATIONS Wire Length Strip Gauge Manual Fire Alarm Stations shall be non-code,with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or 1 1.000" hex. An operated station shall automatically condition it- (2.540) self so as to be visually detected as activated.Manual sta- tions shall be constructed of red colored LEXAN®(or poly- carbonate equivalent)with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters,1.00 inches(25.4 0.750" mm) or larger.* Stations shall be suitable for surface (1.905) mounting on matching backboxes SB-10 or SB-I/O; or 5.500" semi-flush mounting on a standard single-gang, double- (13.970) gang,01 4"(10.16 cm)square electrical box, and shall be installed within the limits defined by the Americans with (cm) Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. E *NOTE:The words FIRE/FUEGO"on the BG-12LSP shall appear on the front of the station in white letters,approximately 4"high. Page 2 of 2 — DF-52004•06/10/05 COOPER Wheelock Series ZRS Strobes, ZNS Horn Strobes and Series ZNH Horns SNAPI- LAMIJFps: Series ZNS Series ZNH Series ZRS Series ZRS Description: Features: The Wheelock Series Z notification appliances feature an easy snap Approvals include: UL Standard 1971,UL Standard 464, on base that is designed to simplify the installation and testing of New York City(MEA),California State Fire Marshal(CSFM), horns,strobes,and hom/strobes. The separate Series Z snap on Factory Mutual(FM)and Chicago(BFP)_ See approvals by base can be pre-wired so circuit wiring can be fully tested before model number in Specifications and Ordering Information the appliance is installed and before the walls are covered. Once ADA/NFPA/UFC/ANSI and OSHA29,Part 1910, 165 all surrounding work is complete, the appliance can be simply compliant installed::by snaping it on the base. Shorting contacts in the base, which provide continuity for circuit testing,are permanently opened EZ Mount SNAP design,with separate base plate,provides when the appliance is installed so any subsequent removal of the ability to pre-wire the base and test the circuit wiring before appliance will indicate a trouble condition on thatdreuitatthe control the walls are covered panel when circuit supervision is enabled.The same base is used • The base plate is protected by a disposable cover and the for all Series Z horns,strobes and hom/strobesto provide consistent appliances can quickly snap onto the base after the walls are installation and easy replacement of appliances if required.Alocking painted. screw is also included for the appliance to provide extra secure installation. • Patented EZ Mount Universal Mounting Plate(ZBASE) TheWheelock SeriesZ appliances incorporate the same dependable —uses single plate for ceiling and wail mount installations circuitry and high efficiency optics that are used in Wheelock RSS Wall Mount models feature field selectable candela settings strobes, NS hom/strobes and NH horns and have the same high of 15/30175111 0cd and 135/185cd performance ratings.The Series Z appliances are compatible with . Ceiling Mount models feature field selectable candela all UL listed"Regulated'panels and all panels that are compatibility settings of 15/30/75/95cd and 115/177cd listed with Wheetcrk RSS, NS and NH appliances. • Strobes can be synchronized using the Wheelock sync modules or power supplies with built-in sync protocol • 12 and 24 VDC models with UL"Regulated Voltage"using filtered DC or unfiltered VRMS input voltage • Strobes produce 1 flash per second over the"Regulated Voltage"range(ZNS,ZRS models) N �sx,.,_ - Selectable Continuous Horn or Temporal(Code-3)Tones with selectable 90 or 95 dBA setting(ZNH,ZNS models) • Selectable 12 or24VDC in 1 appliance(ZNH model) ZNS,ZNH and ZRS - appliances go onto the base plate in a SNAP. APPROVED NOTE:All CAUTIONS and WARNINGS are identified by the symbol.IL All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING.SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TD COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPERAPPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at I flash per second minimum over their"Regulated Voltage Range". - All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series ZNS Strobe products are listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32'F to 120°F(0•C to 49'C)and maximum humidity of 93%(±2%). • Series ZNH horns are listed under UL Standard 464 for audible signal appliances(Indoor use only). • Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1:Series ZNS Ratings Per UL Standard 1971 Table 2:Series ZNSIZNH Horn dBA Ratings Input Regulated Reverberant dBA Anechoic dBA V ModelVoltage Voltage a Strobe Candela Description Volume @ 12f 24 12 24 per UL464 ( 10 VDC (CD)VDC/FWR VDC VDC VDC VDC ZNS-MCW 24 16.0-33.0 15/30/75/110 Continuous High 83 87 89 95 ZNS-MCWH 24 16.0-33.0 135/185 Horn Low 76 81 .84 90 ZNS-MCC 24 16.0-33.0 15130175/95 Code 3 High 79 82 89 95 ZNS-MCCH 24 16.0-33.0 115/177 Horn Low 72 76 84 90 able 3: Series ZNS UL Max.Current' Audible Wall Mount Strobe Models Ceiling Mount Strobe Models Series ZNSIZNH ZNS-MCW ZNS-MCWH ZNS-MCC ZNS-MCCH 24 VDC ZNH-12124 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd Ligh('95))dBA 1633 0.044 0.074 0.107 0.184 0.244 0.350 0.477 0.082 0.124 0.209 0.275 0.3500 dBA VDC 0.018 0.066 0.101 0.177 0.232 0.306 0.429 0.071 0.114 .201 0.261 0.306 0.429 Audible Series ZNS/ZNH 12VDC ZNH-12124 igh(89)dBA 8_17.5 0.021 .ow(84)dBA VDC 0.012 Table 4: Series ZRS UL Max.Current* ZRS-Wall Mount ZRS-Ceiling Mount ZRS_24_V_DC MCW MCWH MCC MCCH Models 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 1633 vdc 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0705 0.189 0.249 0.300 0.420 UL max current rating is the maximum RMS current within the listed voltage range(16-33vfor 24v units). For strobes the UL max current is usually at the minimum fisted voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. • Mrin'g Diagrams* ZNS/ZNH APPLIANCE ZNS AND ZNH APPLIANCES SYNCHRONIZED WITH SM MOD- ULE SINGLE CLASS"B"NAC CIRCUIT WITH AUDIBLE SILENCE + TO NEXT FEATURE SM FROM APPLIANCE F + STROBE PRECEDING CR ECLR A Stroee STROBE APPLIANCE,SWbV_- It. NAC P r 24-8MC Ott Fi�CP Circu t NS NH } +Audble p EOLR SIGNAL Audible Audb� NAC Circuit ZNS AND ZNH APPLIANCES SYNCHRONIZED WITH DSM MODULE NOTE:ZNS/ZNH must be set on Code-3 horn tone DUAL CLASS"A"NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE to achieve synchronized temporal(Code3)tone. Refer to installation instruction(P83983,P83600 DUAL SYNC MODULE respectively). OsYNc+ 'For detail using SM or DSM Sync Module refer OSYNC- to Data Sheet S3000 or Installation Instructions +ouTI P83123 for SM and P83177 for DSM. For 0 +IN' wiring information on the power supplies refer to MINV51 Installation Instructions P84662 for PS-24-8MC. r +AUDIBLE A GNAL C I I -AUDIBLE P +0UT2 + - + +IN2 APPLIANCE APPLLNCE MINUS SIGNAL CIRCUIT RETURN SPECIFICATION&ORDERING INFORMATION Order Strobe Sync w/SM, 24 12 Mounting Agency Approvals Model Number DSM or Code Candela PS-24-8MC VDC VDC Options# UL MEA CSFM FM BFP ZNS-MCW-FR 0304 15/301751110 X X - B,D,E,F X • X ZNS-MCWFW 0305 15/30/75/110 X X - B,D,E,F X X ' ZNS-MCWH-FR 0306 135/185 X X - B,D,E,F X ZNS-MCWH-FW 0307 135/185 X X - B,D,E,F X X ZNH-R 0300 - X X X B,D,E,F X X ZNH-W 0301 - X X X B,D,E,F X ' ' ' ZNS-MCC-FR 0310 15/30/75/95 X X - B,D,E,F X X ' ZNS-MCC-RN O311 15/30/75/95 X X - B,D,E,F X ' X ZNS-MCCH-FR 0312 1151177 X X - B,O,E,F X X ' ZNS-MCCH-FW 0313 115/177 X X - B,D,E,F X ' X ' ZRS-MCW-FR 4085 15/30/75/110 X X - B,D,E,F X X ZRS-MCWFW 0302 15/30/75/110 X X - B,D,E,F X ' X ' ZRS-MCWH-FR 5242 135/185 X X - B,D,E,F X ' X ' ' ZRS-MCWH-FW 0303 135/185 X X - EB,D,E FF X ' XZRS-MCC-FW 0309 15130/75/95 X X - E,F X ' X ' ' ZRS-MCC-FR 0308 15/30/75/95 X X - B,D,E,F X ' X ZRS-MCCH-FR 5240 115/177 X X - B,D,E,F X ' X ZRS-MCCH-FW. 0314 115/177 X X - B,D,E,F X X ' ' ZBASE 5268 Accessory-Includes base,dust cover,mounting screws and installation sheet ZBB-R 6036 Backbox for indoor suface mounting of all SNAP models ZBB-W 6045 Backbox for indoor suface mounting of all SNAP models 'Pending #The ZRS,ZNS and ZNH will mount to single-gang,double-gang,4 octal,4"square and 3-1/2"octal back boxes. NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General AudibleMsual notification appliances shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. These appliances shall be listed under UL Standard 1971, (Standard for Safety Signaling Devices for Hearing Impaired)and UL Standard 464 (Fire Protective Signaling)_ The appliances shall use a Patented Universal EZMount backplate that shall allow mounting to a single- jang,double-gang,4-inch square,4"octal,or a 3-112"octal backbox. Two wire appliance wiring shall be capable of directly connecting to the mounting back plate. Continuity checking of the entire NAC circuit prior to attaching any audible/visual notification appliances shalt be allowed. A dust cover shall fit and protect the mounting plate. The dust cover shall be easily removed when the appliance is installed over the backplate. Removal of an appliance shall result in an alarm condition by the Fire Alarm Control Panel(FACP). Strobes Strobe appliances shall produce a minimum flash rate of 60 flashes per minute(1 flash per second)over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The strobes shall be available with two or four field selectable settings in one unit and shall be rated,per UL 1971,for up to 185 cd for wall mounting and 177 cd for ceiling mounting.The strobes shall operate over an extended temperature range of 32°F to 120°F(0°C to 49°C)and be listed for maximum humidity of 95%RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP). Audibles and Audible/Strobe Combinations Horns and horn/strobes shall be listed for Indoor use under UL Standard 464.The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized.The horns shall have at least 2 sound level settings of 90 and 95 dBA. Synchronization Modules When synchronization of strobes or temporal Code-3 audibles is required,the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. Audibles and strobes shall be able to be synchronized on a 2-wire circuit with the capability to silence the audible if required. If the sync module or power supply fails to operate(i.e.,contacts remain closed),the strobes shall revert to a non-synchronized flashrate 00 COOPER Wheelock 273 BranchportAvenue Long Branch,NJ 07740 Phone: (600)631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION -ix: (732)222-2588 3 YEAR WARRANTY rvw.cooperwheelock.com Made in USA Z1000 ZNSIZNH ZRS 04107 uu heelock INC. Helping People Take Actions"' • • Description: Wheelock Series MB Motor Bells provide a better engineering motor bell for fire and life safety alarm systems. Features: • Available in 6"and 10" sizes in 12 or 24 VDC models. • For combined audible(bell) and visual signaling, Series MB convenient retrofit assemblies(Series RSSP)are available with multi-candela or 1575 cd strobes • Built-in trimplate make semi-flush mounting simpler and less expensive Specification and Ordering Information * RMS current ratings arc Model Order Shell Input Average UL dBA@ Mounting Agency Approvals per UL average RM: Number Code Size Voltage RMS Max* 10ft method. UL max curren . Options# (VDC) CurrentUL MEA CSFM FM BFP rating is the maximum RM: MB-G6-12-R 3942 6" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S X X X x x current within the lister voltage range (16-33v fo MB-G6-12-S 4221 6" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S X X X X X 24v units). For strobes the MB-G6-24-R 3941 6" 24 0.030 0.040 92 D,E,J,K,N,O,P,R,S X X x x x UL max current is usually a the minimum listed voltage MB-G6-24-S 4222 6" 24 0.030 0.040 92 D,E,J,K,N,O,P,R,S X X x x x (16v for 24v units). Fo MB-G10-12-R 3944 10" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S X X x X x audibles the max current is MB-G10-12S 4223 10" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S X X X X X usually at the maximun listed voltage (33v for 24N MB-G10-24-R 3943 10" 24 0.030 0.040 92 D,E,J,K,N,O,P,R,S X X X X X units). For unfiltered FWF MB-G10-24S 4224 10" 24 0.030 0.040 92 D,E,J,K,N,O,P,R,S X x X X X ratings, see installatior instructions. #See mounting options pull out guide in the last section of this binder. X=Approved Description: Wheelock Series 43T AC Vibrating Bells provide durable operation and dependable performance for indoor and outdoor installations. Features: • Available in 6" and 10" sizes • 115 or 24 VAC operation Specification and Ordering Information Series 43T Order Shell Input Input dBA @ Mounting Agency Approvals Model Number Code Size Voltage Current 10 Ft Options# uL MEA CSFM FM BFP 43T-G6-24-R 1627 6" 24 VAC 0.410 86 D,E,J,K,N,O,P,R,S X X X X X 43T-G6-24S 1626 6" 24 VAC 0.410 86 D,E,J,K,N,O,P,R,S X X X X X 43T-G6-115-R 1631 6" 115 VAC 0.085 86 D,E,J,K,N,O,P,R,S X X X X X 43T-G6-115-S 1630 6" 115 VAC 0.085 86 D,E,J,K,N,O,P,R,S X X X X X 43T-G10-24-R 1647 10" 24 VAC 0.410 88 D,E,J,K,N,O,P,R,S X X X X X 43T-G10-24-S 3800 10" 24 VAC 0.410 88 D,E,J,K,N,O,P,R,S X X X X X 43T-G10-115-R 1651 10" 115 VAC 0.085 88 D,E,J,K,N,O,P,R,S X X X X X 43T-G10-115-S 3693 10" 115 VAC 0.085 88 D,E,J,K,N,O,P,R,S X X X X X #See mounting options pull out guide in the last section of this binder. X=Approved 06/05 1K) KNOX" KnoxaBox® 3200 Series Sn"•,m<°�'", ^ 1875 HINGED DOOR MODEL Recessed Mount High Security IndustrialIGovernment Key Box with Face Flange Front View SurMce Mown CE {— e' U . Heavy 1/6"Thick I Stainless 5talnless Steel steel lock cover Door Hinge „ Hole fortamper seal ±LJ1 '1/2"solid plate steel door The number one high-security KNOX-BOX®is used for most with gasket L114.Solkr steel housing 100%welded commercial applications Including businesses, schools, 3200 Surface Mount government and public buildings,community associations and apartment complexes. The 3200 Series KNOX-BOX holds keys, access cards and other small items necessary for emergency access. Front View Side View . ..- T WIDE 3':DEEP The hinged-door 3200 Series KNOX-BOX Is more convenient than the lift-off door version because it allows single-handed 1/4"steel case, operation and opened.or closed,it's ail one unit.. 100%welded Features and'Benefitaa • Holds up to 10 keys or 1 access card in interior T' compartment HIGH • Ensures high security.Box and lock are UL®Listed • Includes a Knox-Coat®proprietary finishing process that protects Knox products,up to four times better Fang` (recessed T'x T'flange than standard powder coat model ony) (recessed model only) • Resists moist conditions with a weather resistant door 3200 Recened Mount gasket • Hinged door allows single-handed operation • Colors: Black,Dark Bronze or Aluminum Ordering Specifications Weight: Surface mount-8 lbs. Tolasurerlueuremeetanddeli Recessed mount-9 lbs. P very of the 3200SerlesKNOX-80X,nlssuggested that the following specification paragraph be used: KNOX-BOX surlace/recessed mount with hinged door,with/without UL Listed tamper switches. 1/4'plate steel housing,1/2'thick steel door with interior gasket seal and stainless steel door Options hinge.Box and lock UL Listed. Lock has 1/8'thick stainless steel dust cover with tamper • Alarm tamper switches(UL Listed) seal mounting capability. Exterior Dimensions: Surface mount body-4'H x 5'W x 31/4'D • Additional rust and corrosion protection(Aluminization) Recessed mount flange-7'H x7'W Recessed Mounting Kit(RMK)for recessed models only Lock: UL Listed. Double-action rotating tumblers and hardened steel • pins accessed by a biased cut key. • Inside switch for use on electrical doors, gates and other Finish: Knox-Coat°proprietary finishing process electrical equipment Colors: Black,Dark Bronze or Aluminum P/N: 3200 Series KNOX-BOX(mars cat.ID) Mfr's Name: KNOX COMPANY KNOX COMPANY•1601 W.Deer Valley Road,Phoenix,AZ 85027•(800)552-5669•(623)687-2300•Fax(623)687-2299•Web:www.knoxbox.com•E-mail:info®knoxbox.com K] KNOW Knox-Box® 3200.. Series Servhg Flre o"nymna Sfmt 1975 HINGED DOOR MODEL - MOUNTING DtAGPAM Recessed Mounting IGt Suggested minbnurt mounting height The 3200 Recessed Mounting Kit(RMK)Is used 8 feet above ground for recessed models only. It contains a shell Large housing and mounting hardware to be cast-in- Optional Thick g rt x RearTamper Steel place In new concrete or masonry construction. 5Mtch Washer After construction is completed,the KNOX-BOX mounts inside the RMK.The RMK may only be used in new concrete or masonry construction. I Installation In Cast Concrete Door To building alarm system To optbnal budding The optional Recessed Mounting Kit is for use Hinge poor Tamper a arlarra Filth F z system in new concrete or masonry construction only. Door— The kit includes a shell housing and mounting 3/8"Grade 5 or hardware to be cast-in-place-The KNOX-BOX is Grade 8 Fastener h mounted into the shell housing after construction Solid concrete wall k Fla a Solid concrete is completed. wall 3200 Series singed Door 3200 Series Zinged Door Dimensions Surface Mount Re Mount Rough-in Dimensions:6-1/2"H x 6-1/2'W x 5'D Inside View IMPORTANT: Care should be taken to insure that -- 718" 3-114" 7/F - the front of the RMK shell housing,including the — 314 _ 3/4 cover plate and Screw heads,is fhtsh,with the. Rear Tamper 8" Switch Hole x® x® 7/Hook Holes finish wall.The RMK must be plumbed to Insure vertical alignment of the vault. 0 $ 2516" -- .o X® t 4" . 1-1 " Reeewd Meuatitg Iising KMK shell is 2-,n6" x o x(3 4 Recefied Mounting Kit[RMI0 mourltcd1n wall during new KNOX-BOX® construction All mounting Alarm Wire Holes marked' 'are mounts inside holes are 7/16' licit Opening KMK shell after Knockouts used for mounting with for alarm diameter.For Rear Tamper at least 3/8"Grade 5 or completion of wire conduit mounting use twitch Grade 8 fasteners construction at least 3/8" Mounting Holes Trim rebar Grade 5 or Grade 8 ' for tie-in fasteners /to wall if ® necessary Attention:KNOX-BOX'S is a very strong device that MUST be mounted properly to -� ensure maximum security and resist physical attack. Knox®Rapid Entry System The Knox Company manufacturers a complete line of high security products Including Kecessed K Knox-Box key boxes,key vaufts,cabinets,key switches,padlocks,locking FDC caps, Flange plugs and electronic master key security systems. For more Information or technical Mounting studs assistance,please call Customer Service at 1-809-552-5669. provided inside KMK shell Concrete or to accommodate masonry wall KNOX-50X9 construction KNOX COMPANY•1601 W.Deer Valley Road,Phoenix,AZ 85027-(800)552-5669•(623)687-2300•Fax(623)687-2299•Web:www.knoxbox.com•E-mail:info@knoxbox.com e Copyright 2006.Knox Company® tscr-rEcmi9-e Global Project`'Vakies Project GOIN'POSTAL Standby 24 1 P e tlD 10321 1 May Prepare r M db I De rating Factor:Factor:I 1.2 Date 11 26 08 Volt # p Wing Threshold 10 • MAIN PANEL Model 5208`FireMcm i Control Panel Max NAC Current 3.0 Amps • STOCK ROOM 1st FLOOR I Volts. 24 VDC. Max el Current 6.0 Amps t$� Current Draw r x e A Ohms Per. L ) Acluat %Dr �' 1 Circuit Nara Qty� Stand Alarm aT 1000 Ft. 1tlf Ohms 'EOLw ,: ': r,Of • SK-5208 Main Control 1 0.140 0.160 SK-5208 P m'd NAC's 2, 0.000 0.060 ,r kLM-R V SK-5208 P m Alm R 0.000 0.000 • ;.� 217 SK-5217 Zone Ex r 0.000 0000 3 SK-5235 LCD Remote 0.000 0000 • 280 SK-5280 Display Mod 0.000 0.000 SK-5220 Dir Con Mod . 0.000 0000 K-7181 Zn Cnvtr0.000r . S 0.000 F Q Serial/Parallel Cnvtr 0.000 0.000 Initiatin Device Ckt 1 0.0000 0.000 Initiati Device Ckt 2 0.0000 0.000 Initiati Device Ckt 3 0.0001 0.095 • Initlati Device Ckt 4 0.0001 0095 'w a r fi • Initiati Device Ckt 5 0.0000 0.000 "�.r�' 'ec'�'"#�rs Initial' Device Ckt 6 0.0000 0.000 • kb Initiati Device Ckt 7 0.0000 0.000 • na • . s r � t Initiating Device Ckt 8 0.0000 0.000 �' ^ : . • • . • • indiati Device Ckt 9 0.0000 0.000 ` 'f Initiating Device Ckt 10 0.0000 0.000 , ••• § F� � • d € * Notification A Ckt 1 0.000 0.184 #14 Solid Notification A Ckt 2 0.000 0.184 #14 Solid JAW;. ;tea :"AI CITT 's 0.000 #14 Solid SEE VOLTAGE DROP CALCS ATTACHED 1pt ;A#dItT 0.000 #14 Solid Aux Power Out 0.000 0.040 #14 Solid 0.140 0.836 C tJ : t� yy � ` ` F3 -_... `e' �... ...: ' , rmAC?? uired •• Command Shortcuts s 2� B The b: Factor 1.20 • ' ' rs`R uired 4.12 $ Configure Circuits Print Page Commercial Fire and Communications r----------------------------------� VOLTAGE DROP CALCULATIONS JOB# 10321 JOB NAME: GOIN' POSTAL DATE: 11/26/08 CIRCUIT# I H = HORN/STROBE WP=WEATHERPROOF DEVICE CANDELA CURRENT WIRE WIRE STARTING NUMBER RATING Cd DRAW LENGTH GAUGE VOLTAGE 14 24 C1-01 76H 0.184 92 23.89 C1-02 0.000 23.89 C1-03 0.000 23.89 C1-04 0.000 23.89 C1-05 0.000 23.89 CI-06 0.000 23.89 C1-07 0.000 23.89 C1-08 0.000 23.89 CI-09 0.000 23.89 C1-10 0.000 23.89 C1-11 0.000 23.89 C1-12 0.000 23.89 CI-13 0.000 23.89 C1-14 0.000 23.89 CI-15 0.000 23.89 TOTAL VOLTAGE CURRENT 0.184 AT 23.89 DRAW LAST DEVICE Commercial Fire and Communications r----------------------------------� I VOLTAGE DROP CALCULATIONS JOB# 10321 JOB NAME: GOIN'POSTAL DATE: 11/26/08 CIRCUIT# 2 H = HORN/STROBE WP=WEATHERPROOF DEVICE CANDELA CURRENT WIRE WIRE STARTING NUMBER RATING Cd DRAW LENGTH GAUGE VOLTAGE 14 24 C2-01 75H 0.184 41 23.95 C2-02 0.000 23.95 C2-03 0.000 23.95 C2-04 0.000 23.95 C2-05 0.000 23.95 C2-06 0.000 23.95 C2-07 0.000 23.95 C2-08 0.000 23.95 C2-09 0.000 23.95 C2-10 0.000 23.95 C2-11 0.000 23.95 C2-12 0.000 23.95 C2-13 0.000 23.95 C2-14 0.000 23.95 C2-15 0.000 23.95 TOTAL VOLTAGE CURRENT 0.184 AT 23.95 DRAW LAST DEVICE