Loading...
HomeMy WebLinkAbout08-8630 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8630 FIRE ALARM SYSTEM PERMIT Permit Number: 863) Address: 38634 CR 54 Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02-26-21-0000-01400-0000 Improv. Cost: 7,200.00 Date Issued: 12/22/2008 Name: FAITH BAPTIST CHURCH INC Total Fees: 200.00 Address: 38634 CR 54 Amount Paid: 200.00 ZEPHYRHILLS, FL. 33542 Date Paid: 12/22/2008 Phone: Work Desc: INSTALL FIRE ALARM SYSTEM STATE ALARM INC FIRE ALARM 50.00 FIRE INSPECTION FEES 50.00 FIRE PLAN REVIEW FEES 100.00 FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." ,4v C TRACTOR SIGNATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 111111111111 111111111111111111111111111111111111111111111111 2008178444 QT1c QF CQMM11 NcEM NT Am,ul?la. Rept: 1217714 Rec: 10.00 DS: 0.00 I T: 0.00 pto,xetyidcru16estintta0 - -" a-A�JO 12/16/08 - Dpty Clerk e � IRE UNMGLWN )Oaeby l y+naEoa that anprvrertaaYs wiU be olatla to seelaot real poprty ntd is aceardancn wi�J.Section 713.13 of t:Florida Slaadn,tha P owk Mforest(nn Is phwidod in this TOT7CB OF caMMF(Ql►tgrl 1.neaa tim,rprovexn{+fr�rr.�er lm max..+ 'r.' e t .o9 fa.> 6.39 30-E'r of AIf fr- 2.Goeeeal Um3$ Cc�ryh. Qs �v.1�4!? Zw.�L oaf 7f�C33� +�itoaof�mprrt4 r _______' ' 3.Owav LsRar�pse b e m.d of -FVI1.S 11rr r,j, p'F. rI:7/s 3i t o)1nxiipinij, e$ddtdtlQ(ifad>ec>hm tssro�} 1-CaNrvt)K tdats%dW a)Kmte eetd addi . .3 pp��..,,,,b1 Tetephaee Nn: 9f34 — AP/� t Fax Na( 1 1. �Bt ! f.Swey hftinamxi a)Ame and 1dQus' e)Ts3ephmeNa: F1tc lOvt) "- a}Natac ad address /C/1f 7.Identityofpern�nihitth SydeeocFriddat!taead Nsnae and adtllHs; by vdtorn no*ticar er Otto documms mg 6a sen ed b)Tdcpbme No.: (�) L h'sddvim ro hi pdG owm d the falltrsugg polo=to recei.e a copy otea Limon)@note as prwidod b•S cio r 713.I3(1)tb).Ptorrda Stsmues: s)Nstaa sad addleas' t me No.:b)Te1m F7ar No(Opt) 9.MTbaloa6do elfadw afcarnmaroamtett(the Asrc is one year f omm the doss at netord>td rodeos a diflE ettdetc is Specific WAR.'VI:Y[i TOOINNM ATPY PAY1sCY1S MADE RY TILE OW:ilk AY ER TM IMK AT[Ot US TUC A•OfCJS OF CtO;i1�T ARY CCIP1 UZZ11M PAYbtErm vjmz ER CItAPm 713,PART L 3XCTIOI5 713.17. A POT}CE OJr C B11 fr MVSI'BE RSL'ORDID AND iosr D ON TRZ J H Site 5EFc i ifz FIRST 1N 'LCTICN.IF YOU!N-M'kw TOOBT4JN I1P ANCIPDG,C(Y'QILT Y LLmER Ott A?I ATt O)UYEY HSFORE C0bQMW yc WORM OR RRCOPDNa YOCR 1t0'RCt A p�A ate, Co&wVFPLaJllll goexrYorrAsco __ ,ia4) s ar Iheitre3°i�giiaurmentwatahiuw befoie➢rathx dsyot ,20 ,by_____ for T ( of jt5ev (� pa Iitsdtnity Bnown_OR Fmduoed Idap5eafioo 10 Nu. SI mr V'—c - IPCQtldri1i5c Pt ,ill cc cr t i _____ I-•� 1/at:Reaion p2 a,ut 10 secaoe 92.525;FlaidaSUM&Under peralnec otP Y. Nrc I have m.d ate teee;otcs.ed for dw*ds owad id it am the to aw bast ofd Intorrl,*and bc3d JED PITTMAN, PASCO COUNTY CLERK Leigh J. Cant 12/16/08 03:24pm 1 f Commission#DD402182 OR BK 7984 PG f 22 ko Expires March 21,2009 OF F-�ionded Troy Fain-Insurance,Inc.800385.7019 STATE OF FLORIDA COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING ISA TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC CORD IN THIS OFFICE WITNESS MY HAND AN 0 F CIAL SEAL THIS__ _ DAY OF 2424 JED C AN,CLERK OF CIRCUIT COURT BY DEPUTY CLERK AUG/30/2007/THU 11 :07 AM ZEPHYRHILLS BUILDING FAX Xo, 313-720—'7021 P. 002/007 813-7a0-0020 City of Zephyrhlils'Fit : Fax-813.780.0021 aY Permit Application. t scion Date Received —( - :Phone Contact-for Permit 3 oZ c 93 9 Owner's Name i)i, ,tJ C' Owner's Phone Number L III] [ I _ Owner's Address C L/!! •5 v to S ft.. 3359' Fee Simple Titleholder Name A//A7 Titleholder Phone Number II II Fee Simple Titleholder Address Job Address - .s �y `- Lot Sub Division .11 /— pOQJiX Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier It or RQ Facility)ANNUAL EJControlled Bum Hood Installation Emergency Generator-30 kw LP/Natural Gas-installation Emergency Generator z-30 kw LP/Natural Gas-ANNUAL Sale El Fire Protection Maintenance-ANNUAL [ ] Places of Assembly-ANNUAL em �Jnr ❑ Sprinkler 0A ❑ �J Recreational Bum F1re/Nemr I liii] Sparklers Hood Cleaning [IJCI d ❑ lJ [ ] Sprinkler System installations /D" Standpipes S nkler S e -o8Hood Suppression ❑ Q ❑ T ( pr' Sy c) Fire Alarm Installation Torch Rooflrtgfrar Kettle A 1OQ, Fire Pumps El Waste Tire Storage ANNUAL V /v Fire Works Flammable Application-ANNUAL [ 72_OQ._001 Valuation of Project Fuel Tanks u Other. Contractor Company ill t Signature Registered Y I N Fee Current Y/N Address 7 v f' _ j5 > Ucense# - - 5LECTRICIAN Company Signature Registered Y/N Fee Current Y!N Address License# PLUMBER Company Signature Registered Y I_NI Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER r j Company Signature Registered Y/N Fee Current Y/NI Address Ucense# Directions: Fill out application completely- Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) if over$2500,a Notice of Commencement is required(Mechanical work over$6000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(httpJ/appealser.peacogov.com) AUG/30/2007/THU 11 ; 53 AM ZEPHYBHILLS BUILDING FAX No, 313-780-0021 P, 003/007 NOTICE OF''DEED RESTRICTIONS: The.undersigned understands that this permit may-be!subject!to-4'deed"Trestrictions ..which may be more restrictive than County-regulations. The,undersigned-assumes.responsibility:forrcompliancetwith any .. . .applicable deed restrictions. UNLICENSED CONTRACTORS .AND CONTRACTOR RESPONSIBILITIES: if the owner has`hired-ca-contractor-or- - contractors'to undertake work,they may be required to be licensed in accordance with state and local-regulations. If the contractor is not licensed as required by law, both the owner:and contractor may be cited-for a-misdemeanor violation under state law. If the owner or intended contractor are uncertain,as,to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired:a contractor or contractors, he is advised-to have the contractor(s) sign portions of the "contractor Block" of this application-for which'they will be responsible. If you, as the ownersign:as the contractor, that may be an indication that he is not properly licensed and is not entitled'to permitting privileges In Pasco County. CONSTRUCTION LIEN LAW(Chapter7.13,Florida Statutes,.as.amended): If valuation of work ls'$2,500.00 or more, I certify that 1, -the applicant, have been provided with a copy of'the "Florida Construction Lien Law—Homeowners Protection Guide".prepared by-the Florida Department of Agriculture and Consumer Affairs. if the applicant is someone other than the"owner", I certify that i have obtained a copy of the above described document and promise in good faith to deliver It to the"owner" prior to commencement. 'CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes,..zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. •If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior-to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(8)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official;for a period not to exceed ninety(90) days and will demonstrate Justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the Job is considered abandoned. 'WARNING TO OWNER: YOUR FAILURE TO RECORD A"NOTICE OF COMMENCEMENT MAY°RESULT INYOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT �V/� _ CONTRACTO SupsgdJed nd sw ( r a ed)b fore me this Subscribed and sworn to(or rmed)before meth by Who Islay on nown to a or ave produced Who Is/are personally known to me or has/have produced as identification, as identification. ( ) blic Notary Public ommi sion No. tot - ISSION a DD7608I8 Commission No. WI►)•N(ITARY 0► FI.Notan Discount Ascot.Co. 1• Name of Notary typed'.prints s m - Name of Notary typed,printed or stamped TRANSACTION REPORT P • 01 /01 DEC/02/2007/SUN 01 : 53 PM F ( T # ATE START T. RECEIVER COM.TIME PAGE TYPE/NOTE FILE 01 EC/02 01:53PM 269542 0:00:25 1 OK SG3 98 5 Zephyrhills Fire Rescue 6907 Dairy Road.Zephyrhi ls,FL 33542 Fire Marshal Bus 3)780-0041 Kerry Barnett Fax(81 80-0044 E-mail:kbarnett@fire.zephyrhi Plan Review#:08-149 Project:Faith Baptist Church Number of Pages: l plus specs and oaks Date:November 28,2008 I have reviewed the plans for the fire alarm installation located at 38634 CR54 E and will require additional information on the items listed below.There is no charge for review at this time.The charge will be assessed one plan is fully reviewed. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. Battery cabs appear not to be correct.Under the section for figuring power supply required for the born/strobes only I device is listed for each type when there are 7- 15 cd strobes,4-75 cd horn/strobes and 3—15 cd horn/strobes. 2. Kitchen ansul system shall be tied into the system. FIRE MARSHAL *S*Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the , submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local or4mances..In the event that Aut cr examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.Tho City assumes no responsibility lbr the contractor's ihilure i to be in compliance with all applicable NFPA codes and local ordinances. De< 1o_ 7. FL 33542 6907 :Jc:ei';1 i`.ue�C;, �..`?;�t??1i-131t5, . _ . _ Fire ";hies. ' l.l�. (. f...�_ (6l3)730-004 . �0 Fi"e 4.�.: , J ii.ic3�1,� +L3J i •� )l =�-� `�•: _.: (83730-0044 FIRE SERVICE USER FEES Occupancy No.: �rr'�.� _ Plan No.: - /99 Contractor. � `l ,9%/ -// ' -Business Name: Billing Address: i7 J�=. Business Address: I-t! Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Spwider $50 let Alarm WC 06 at let Re-inspection WC LI Standpipes $50 U 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C 0 Plan Revisions DBL 3rd Renapecllon $2250 $50 4th Alarm $100 4th ReNmpecton $500 Fire Alarm 5th Alarm $150 SPRMNf1.ER SYSTEMS (Business closed until LP Gas 6th Alarm $200 80-25 Heeds $50 violations corrected) Natural Gas $50 NON CONPLUNCE $150 26 plus Heeds $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 0 Per Ricer $50 J Hydrostatic Test $65 perviawm Fire Works $500 FIRE PUMP JJAcceptance Test $45 per widem Camp Fire $25 ❑Per Ptarp $100 U Hydrant Fkav $75 Controlled Burn $100 FIRE ALARM SYSTEM Hood/Duct $50 fl 0-25 Devices FIRE ALARM SYSTEM Place of Assembly $50 Annu i plus Devices $1 [/System Acceptance Fire Protection $25 SUPPRESSION UPPSSION SYS Recall Acceptance Flammable Application $50 Annum Wet $50 OTHER Waste Tire Storage $50 nnnwi Dry $50 Fire WeWSmole Well $15 perms Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 pereyrem Rio-Hazard Waste $100 Ann at KITCHEN EXHAUST Furnfon Tenting $50 Hood/Ducts $50 Tart 10'x10'or greater $15 portent Torch Pot/Applied $50 OTHER Fire Pump $45 Has.Ma $100 Amnrl LP trraton per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 E Hood/Duct $30 Natural Gas In ioloeon $60 Re•inspsdion DBL (Per System) (other then annual) 0 spray Booth $50 Inspection Scheduled DBL and cancelled less than 24 hours Construction insp. N/C___ H Emergency Vehicle Ac' $50 FALSE ALARM PLANS TOTAL/áv.._.- ���'�" - INSPECTION TOTAL PERMIT TOTAL TOTAL GRAND TOTAL Comments: Date: �,/2 /'E lns%ctor. /(r 4t2i — / — Zephyrhills Fire Rescue 6907 Dairy Road,Zephyrhills,FL 33542 Fire Marshal Bus(813)780-0041 Kerry Barnett Fax (813)780-0044 E-mail: kbamett@fire.zephyrhills.fl.us Plan Review#: 08-149 Project: Faith Baptist Church Number of Pages: I plus spec and calcs Date: December 10,2008. I have received and reviewed u ,letterxia fax and will allow this project to move forward based on your aclmowled`gement of correcting the issues previously noted on November 28, 2008 during the initial review. Payment for permit contractor acknowledges agreeing with items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. Installation shall be in compliance with all applicable NFPA codes. Inspections Required: 1. Acceptance Test KE ITT, FIRE MARSHAL *"*Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. State Alarm Inc. Corporate Office: 5956 Market St. • Youngstown,OH 44512 Serving NEW PORT RICHEY,CORAL SPRINGS,ORLANDO,and SARASOTA FLORIDA 813-926-9391 Fax 813-926-9542 FL CERT LICENSE#EC13003517 FIRE ALARM SYSTEM INSTALLATION FAITH BAPTIST CHURCH 38634 HIGHWAY 54 EAST ZEPHYRHILLS, FL. 33542 Please be advised this review of plans submitbd is a cursory review to assist the contractor in compllance a lh applicable fire safety codes. This review is not ceded to be a final approval of the submitted contractor's sole responsibility to ensure that the l is the ans are complete compliance with all applicable NFPA codes aid in local ordinances. In the event that site inspection reveals der examination or the contractor's a ,it shall be sole responsibility,at their sole expense b bring those areas in compliance. The City assumes no rosponsibfiity for the contractor's failure b be in compliarape with all applicable NFPA Codes and bcal O dine m& SUBjJ.ED PLANISI HAVE B B Y ZEPHyRHILL$ EEN REVIEWED Bees: SHAL'S O CE Reviewer: � tt t� ntit 1 3 'H - 'y r+ i �cs 4 veu, Battery >� Facility Information conbgency sRx gt 1 Enter Standby and Alarm Times Factor 3s Location: Faith Baptist Church a Battery Standby(hours): 24 Account# Alarm Duration(minutes) 4 % En meer: ai ` Date 11 �t1 �� ,• ' ._¢. ,„<, SELECTED PANEL MAXIMUM OUTPUT RATINGS Polling Standby Alarm Panel Pane/ Bell#1 Bell#2 Max Battery Auxiliary Auxiliary Standby Outer Output(N Maximum Panel Maximum Panel Select Panel from pulidownlist: Loop(mA) Power(mA) Power(mA) (mA) Alarm(mA) (mA) used;mA) Standby Output Alarm Output Supported by VEsta 128FBP V 128 1000 1700 300 470 1700 1700 1300 2800 34,4 9 44 0 55 150 ¢ 0. o s 0 55 15P 128.0 9454 1550.0 • 1700.0 17000 1245.4 26500 h ^ How many - ' Enter powered »`° KEYPADS Quantity externally? 0 o 0 0 0 hr 0 0 0 0 0 0 0 0 0 6139/6139R 0 0 40 100 0 0 0 49 0 0 0 0 0 0 0 0 0 04 ¢ 0 0 0 0 0 4 6160/6160CR 1 0 45 150 45 150 0 (' 6160RF 0 0 50 150 0 0 0 6160V 0 0 60 190 0 0 0 8132 S m hony) 0 0 350 400 0 0 0 Add'!Ke pd Enter#and Currants 0 0 0 p p 0 p t s How many _ 2 WIRE&4 WIRE SMOKE DETECTORS Enter . 4444powered (except Vplex Polling Loop detectors) Quantity externally? 2 wire smoke detector(zone powered) 0 Two-wire smoke detector current is built into the panel budgets. These fields are 2 wire smoke detector(zone powered) 0 included to help you create a complete equipment list. The line below indicates if 2 wire smoke detector(zone 1. powered) 0 number of detectors exceedspanel ca acity. 2 wire smoke detector(zone powered) 0 € r 12V 4-wire Smoke(Qnt'y&Currents) 8 0 1.2 0 9.6 0 p s r ; 12V 4-wire Smoke(Qnt y&Currents) 0 0 0 0 0 0 0 ' 12V 4-wire Smoke(Qnt y&Currents 0 0 0 0 12V 4 wire Smoke(Qnt' &Currents) 0 0 0 0 0 0 0a 44 d 44444 ..1 � . 7 fir ` a c ,r. xF 44 How many 9 9. Enter -:>-o MULTI-POWER DEVICES powered Quantity externally? . 4208U(powered b (pa by polling loop] 0 0 0 27.3 0 0 0 0 4208U[powered by panel aux power] 0 28 0 0.6 0 0 0 0 4208U(powered externally] 0 4208SN[powered by polling loop 0 0 0 33.6 0 0 0 0 4208SN(powered by panel aux power] 0 33 0 0.6 0 0 0 0 4208SN[powered externally] 0 33 0 0.6 0 0 0 0 I a 4208SNF[powered by polling loop] 0 0 0 33.6 0 0 0 0 4208SNF(powered by panel aux power] 0 40 0 0.6 0 0 0 0 4208SNF(powered externally) 0 40 0 0.6 0 0 0 0 � � M 4208SNF(Class B to A Zone Converter) 0 0 40 0 0 0 0 0 0 " 4209U Grouped Zone Mux.Module 0 0 110 0 15.5 0 0 0 0 4297 Polling Loop Extender 0 0 178 0 0 0 0 n, Add'!Device(enter quaff.&currents) 0 0 0 0 0 0 0 0 0Fe Add?Device(enter uant&currents) 0 0 0 0 ss 0 0 0 0 .1 E � M. I <�RTis t379 ? /1 2975 AYHEA[) RU. DADE Cs.1",: FL 3 523 ,x•, o--e rg' ` ,,. "k� A,_, s,'s",� .,k< ,..,,,, a :ro -v t'"^": ��a ' � 9 How many xy 12V NOTIFICATION DEVICES ON Enter powered Alarm BELL OUTPUT#1 Quantity externally? . Current(Aux) Enter device name,quant.,&current 0 0 0 0 0 Enter device name,quant.,&current 0 0 0 0 0 ir Enter device name,quant.,&current 0 0 o Enter device name,quant,&current 0 0 0 0 0 Enter device name,quant. &current 0 0 0 0 0 .. 3� � V. ��� r 4. r� V. How 12V NOTIFICATION DEVICES ON Enter powered Alarm % < V �€u t BELL OUTPUT#2(IF USED) Quantity externally? Current(Aux) ...r.. Enter device name,quant.,&current 0 0 0 0 0 Enter device name,quant.,&current 0 0 0 0 0 Enter device name,quant.,&current 0 0 0 0 0 Enter device name,quant.,&current 0 0 0 0 0 Enter device name,quant.,&current 0 0 0 .,_. 0 Vi <- a ,. 0 12V AUX POWER AND BELL CIRCUIT p 'WIRE RUN DATA a >'r a Panel Aux Power Wire Run(twin lead Feet V <Select Wire Gauge> 0.00 0 0.00 1200 0.00 Panel Bell 1 Wire Run twin lead) Feet V <Select Wire Gauge> 0.00 0 0.00 12.00 0.00 4.?'), Panel Bell 2 Wire Run twin lead) Feet V j<Select Wire Gauge> - 0.00 0 0 0 00 12 0 000 P.g r > Standb/Alarm Durations(from top) 1, V Battery hours Standby to � Y( 1: Alarm Duration(minutes): air 0 PS24 POWER SUPPLY MODULE,MAXIMUM CAPACITIES v - a } ,' Panel 12V Panel 12V Output A Output A Output a Output B PS24 PC Maximum Total Maximum Total Max.Battery f ,'C• ^r `" Standby(mA) Alarm(mA) Standby(mA) AlaAlarm(mA) Standby(mA) ( A) Board(mA) Standby Output Alarm Output capacity gal �yr4 i t A) s a 570 1700 570 1700 40 610 4180 34.4 0.0 00 0 2 0 0 40 40 4 '4' £' yg F Kea !. ' 3'. 354.6 6200 570.0 1698.4 570.0 1700.0 570.0 4138.4 34.4 24V NOTIFICATION APPLIANCES `= Enter Device Names&Specifications «' ty x ° System Sensor Horn Strobe 110cd 1 Output A 0 0.202 0 0.202 0 0 u-• System Sensor Horn Strobe 75cd 1 Output A 0 0.632 0 0.632 0 0 a " System Sensor Horn Strobe 30cd 1 outputA � 0 0.094 0 0.094 0 0 System Sensor Horn Strobe 15cd 1 Output A 0 0.198 0 0.198 0 0 System Sensor Strobe Light 15cd 1 output A V Y 9 0 0.462 0 0.462 0 0 a 24VNotification Appliance 0'Output A _ 0 0 0 0 0 0 24V Notification Appliance 0,output A 0 0 0 0 0 0 �„' 24V Notification Appliance 0 output A 0 0 0 0 0 0 Output A 24V Notification Appliance 0 0 0 0 0 0 , 24V Notification Appliance 0 output A 0 0 0 0 0 0 ay 24V Notification Appliance 0 output A 0 0 0 0 0 0 .. 24V Notification Appliance 0output A 0 0 0 0 0 0 24V Notification Appliance 09A A 0 0 0 0 0 0 24V Notification Appliance 0 Output A 0 0 0 0 0 0 Output A 24V Notification Appliance 0 0 0 0 0 0 0 24V Notification Ap Fiance 0 Output A V 0 0 0 0 0 0 � 4 24V BELL CIRCUIT WIRE RUN DATAE ' PS24 Out ut A Wire Run twin lead Feet V <Select Wire Gauge> V 0.00 0 0.00 24.00 000 PS24 Out ut B Wire Run twin lead Feet V <Select Wire Gauge> V 0•00 0 0.00 24.00 000 ...,� _HassF,�'° <a Fii• ` s,4m ., ,. '� ^a: *,w11 Honeywell VISTA-128FBPN128FBP-24 COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM 1.SIA CPO 000 cica pv'—be JISTA-12SSIA Designed to integrate seamlessly with CCTV, access control RE receivers and relays are supported by this extremely and Honeywell's full range of fire and burglary components, powerful control platform. The VISTA-128FBP has been the new VISTA-1 28FBP provides the ultimate protection of life designed to mount quickly and easily in an attack resistant and property.The UL listed Commercial Fire and Burglary cabinet, and is available in 12V and 24V models.A Control Platform controls up to eight partitions and supports revolutionary new feature called Panel Linking allows multiple up to 128 zones/points using hardwired, wireless and V-Plex partitions, panels—even buildings—to be armed, disarmed addressable technologies.A diverse line of Honeywell and have status checked all from one location. initiating devices, notification circuits, digital dialers, keypads, FEATURES •Eight hardwired zones standard, •Supports CCTV applications with •Supports Remote Control via expandable to 120 V-Plex the new VistaView-100 CCTV the Internet`* addressable points/zones or Switcher Module 128 wireless points/zones •Supports Internet Alarm Reporting" •Identifies the point or zone of a fire or •Can control eight separate areas alarm using the new FSA-8/FSA-24 Fire •Supports Graphical User independently(8 partitions) System Annunciator Interface Consoles •Supports Panel-Linking allows •Programmable to meet SIA false alarm •Supports up to 250 access card up to 8 systems or building to be prevention specifications and UL holders using VistaKey controlled from one central location approval for ANSI/SIA CP-01-2000 •(using VA8200) orderpart number VISTA-128SIA Supports p to eight AlphaNumeric Pager up to different numbers using •Supports Commercial UL Wireless Fire •Two on-board notification(bell)circuits the VA8201 and Burg delivering 2.3 amp @ 12V or 3.4 amp Connects to Northern Computers PassPoint •Stores up to 512 events and can ©24V Access Control Systems.Maximum 32 doors. accommodate 150 user codes •Automatic smoke detector sensitivity when used with AlarmNet-i. •Supports V-Plex addressable VistaKey maintenance testing access control(1 to 8 doors) •4-wire smoke reset using onboard •Supports up to 16 doors of J2 output trigger access control using VISTA •Supports Dynamic Signaling for Gateway Module(VGM)* LRR backup VISTA-128FBP/ V128FBP-24 COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM ADDITIONAL FEATURES •Notification Appliance Circuits(two): -Increased current draw capacity •Access Control integration -Programmable (128mA) -Full integration with PassPoint --Temporal code compliant -Supervised by panel Access Control System -Individually silenceable -Individually assignable to Complete Gateway interface of •Programmable on-board auxiliary relay partitions,notification circuit VISTA and access functions (bell)output or aux relay •SIA false alarm reduction features: -4,000 ft.capability without the •Up to 8 doors using VistaKey -Exit error logic use of shielded cable V-Flex Access Control Exit delay reset -Extender/Isolation bus module •Event reporting -Cross zoning -Two-wire smoke detector -Call waiting defeat zone/group expansion module •Local printer of access or VISTA related event -Recent close report adds two or four zones •Scheduled uploading of events to Eight zone—Class A and B •Supports commercial hardwired,addressable extender module central station V-Plex polling loop and wireless zones -Eight zone-Class B extender •Stored events for one call retrieval •Hardwired zones module •Communication -Provides eight style B hardwired zones -One zone supervised contact -EOLR supervised for Fire and monitor module -Phone mapping by zone response type UL burglary installations •UL Listed wireless expansion -Supports VIP interactive phone -Supports N.O.or N.C.sensors —Supports up to 128 wireless voice module -Individually assignable to any zones/points using 5881ENHC -Panel operation during eight partitions receiver download -Up to 32 two-wire smoke -Supervised by control for -Uploading equipment list to detectors each on zone one and check-in signals central station two(64 total) -Tamper protection for -Communication to PassPoint via VISTA - Up to 50 two-wire glass break detectors transmitters Gateway Module on zone eight --Individually assignable up to eight partitions •CCTV integration •Patented addressable V-Plex polling loop -Supports VistaView-100 ECP based technology Supports UL864/NFPA —Supports 120 two-wire zones points approved wireless smoke detectors CCTV switchers -Global polling technology for faster processing 42J8t1 d195N .... l92 Fir-znne I ` e 1.2 4 DnNF S,eke Exoans:on k1&e Moc lle S :oke E 3.t Z e o ctor J-?LFX oe.e,.ta Loop " rfo ule 7:a sssi Vtn W,re Zones Fece�F t 1'0CR H Aoa AL o Lc: lle •V t M1 c 10( Ac tol '.. pt licffi:er:Aool 9nGes 42(o4 NAC.(3elp R lay C .��4204 CF MUaule Elgnt Class C r`.artlare Zones Pa al el Printer `_ 416 5 m L:a k �S lcn r 4 fi.;le Or ticn Serial pole r 4100S. Pr tiler � ntt nl e naoo.,le rsas2 N ct _ror;An canoes- 2p5 Pir.ter Alpha Paging , Module P. L-1e: ...t, stator- , 7720U!F ieng ?g35GF Cellular Range Ratl:o Rzdio SPECIFICATIONS Applications •Aux. standby pwr: 12VDC, lAmax Environmental The VISTA-128FBP control is well •Total power: 2.3A at 12VDC,3.4A at •Storage temp: 14°F to 158°F suited for a variety of applications as 24VDC from all sources (-10°C to 70°C) an integrated fire and burglary control.A diverse line of ADEMCO initiating devices •Standby time: 24 hours with 1A standby •Operating temp: 32°F to 122°F supports this extremely powerful control. load using 34.4AH battery (0°C to 50°C) Some of the applications supported are: medical and professional buildings, •Fusing: Battery input.aux. and •Humidity: 85%RH churches or synagogues, office buildings, notification(bell)circuit outputs are • schools,strip malls, larger residences and protected using PTC circuit protectors. EM Meets or exceeds the following factory or warehouse environments. All outputs are power limited. requirements: —FCC Part 15,Class B Device Installation •Optional 24-volt power supply, PS 24 -FCC Part 68 The VISTA-128FBP alarm system has Supplies two 24 VFW, 1IA full wave —IEC EMC Directive been designed to mount both quickly rectified, unfiltered outputsMain Dialer: Agency Listings Burglary and easily. It meets all applicable •Line seize: Double Pole • UL609 Grade A Local Mercantile requirements for UL commercial fire Premises and Mercantile Safe and Vault and burglary installations. •Ringer equiv.:0.7B •Formats:ADEMCO Low S •UL611/1610 Grades A,AA, Speed,Specifications Electrical , Central Station •Primary power: 18VAC @ 72VA ADEMCO 4+2 Express, ADEMCO High Honeywell No. 1451 Speed,ADEMCO Contact ID, Sescoa •UL365 Grades A. AA Police Connect and Radionics Fire •Control panel quiescent current draw: 350mA •Dual phone line capability(using •UL864/NFPA72 Local,Central Station 5140DLM module) and Remote Station •Backup battery: -12VDC, 12AH min to 34.4AH max Cabinet dimensions •Factory Mutual -Lead acid battery(gel type) • 18"H X 14.5W X 4.3"D •California State Fire Marshal •Alarm power: 12VDC, 1.7A max for •MEA each notification(bell)circuit output Total 2.3amps @ 12V •UL985 Mat;l P.,II Sta!,ans 5140MP.c-I' 514^MPS-2' 100SN 19°"N 4-Flex Twa-lone al;nterfar_C Expood' 4293SN 4944SN :J�d°le -Plea Ad-ter ACCre;_axle Ter_.,r S.U,h' F'. - »ces -d Mcur,t f to tiwitcn• N r�lc,;,Rei.e.v.,r r°.tacl ECP auS (Max Tw• %u Terre Sod I' a23' 139! P r I'H.0 • Extent' \".ad°le R d- actor S tore n �{� R U Alpha -eteCtC a l4 ,;s FR e,ad 4209,J y Gr pZ n 1 120% FP ., ..y,.�—.—..._ S ModCle C Ga°/N.ntlow otoco c3 _ Moo at it f. toG t c 19.SN Tr» m °r 5 okeM1.,.l .' S,;pp°rs U To,5, " i, T 'Ho Dete,.tars on 2 ire T4,POZ000 _.._................. jI Pessiolrt ..-�. Et• \'-M(PT GM) •••,►. ?►-* `VISTA co�y�oc es Up T°E; Module ';a.:i nicnal z-w,r;> S ko o°:attars nel I'5,,ct Panel l.l,:kn,� ~!t,'RdUle Module VISTA-I 28FBPN1 28FBP-24 COMMERCIAL FIRE AND PARTITIONED BURGLARY ALARM PLATFORM SPECIFICATIONS Auxiliary Devices •4297 Isolation/Extender Module Commercial Wireless Devices •6160CR-Red Alpha Keypad V-Plex(addressable)Smoke •5808W3-Photoelectric •6139R-Red Alpha Detectors: Smoke/Heat Detector Keypad/Annunciator •5809-Wireless Heat Detector •FSA-8&FSA-24 annunciator modules •5192SD •4192SD •4192CP •5817CB-Wireless Commercial •4204-Relay Module,four form C •5192SDT •4192SDT •4192CPM Transmitter contacts •4192SDTM •5869—Hold-Up Transmitter •4204CF-Two supervised output V-Plex Passive Infrared Detectors •5881 ENHC-Commercial Fire/Burg circuits •998MX Receiver •5881 Series—RF receiver supporting •4275EX-SN 5800 wireless detectors •4278EX-SN Access Control •6220S-System printer used with •VistaKey V-flex(addressable) 4100SM serial module V-Plex(addressable) Contacts Access Control •4939SN-WH •VistaKey-SK Starter Kit Two-wire smoke detectors •VistaKey-EX Expansion Kit conventional •4944SN-WH Y •4959SN •VGM Vista Gateway Module to •2100 Series Photoelectric PassPoint Access Control(Northern •2400 Series Photoelectric V-Plex Glassbreak Detectors: Computers) • 1100 Series Ionization •9500SN CCTV Four-wire smoke detectors VISTA interactive phone module • VistaView-100 CCTV Switcher conventional •4286 Voice Module or Module •2112/24 Series Photoelectric • 1412 Series Ionization Optional 24V Power Supply Alarm Communications Horn/Strobes •PS24-24V power supply-3.4A •Graphical user interface with Long Range Radio: Internet capability •System Sensor Notification Appliances •Long Range Radio 7720ULF-XX, • Internet Remote Control-Networking Manual Pull Stations 7835C, 7835CF, 7845C Module •5140MPS-1 • Internet Alarm Communicator(7845i) •5140MPS-2 Upgraded software •7845GSM-Digital Cellular •Upgraded Compass Downloader • Communicator V-Plex(addressable)Devices Windows compatible •7845i-GSM Internet and Digital •4208U Loop Expansion Module Wireless Devices Cellular Communicator -eight zones •5804BDV-Bi-directional with voice Paging •4101SN Single Relay/Zone Module •5804BD—Bi-directional Key •4208SNF Class A/B Expander Module •5804Watch-Wireless Key&sports •VA8201 AlphaNumeric Pager •4209U Group Zoning Module watch combined —two/four zones •5816—Door/Window Transmitter •4190SN Remote Point Module •5804-Wireless key -two zones •5827BD- Bi-directional Keypad •4193SN Two Zone Serial Interface •5890-PIR Module •5849-Glassbreak Detector •4293SN One Zone Serial Interface •5819-Shock Sensor Module ORDERING VISTA-128FBP Commercial Fire and Partitioned Burglary Alarm Platform 12V Model V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Platform 24V Model Honeywell Security&Custom Electronics p Q Honeywell Honeywell 2 Corporate Drive Melville, NY 11747 Tel: 800.467.5875 VV128FBP,D March 2007 www.honeywell.com O 2.007 Honeywel nrernaronai Inc. Page 1 of2 • M i AL602ULADA NAC Power Extender Overview Model AL602ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery charger. It may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories. The unit delivers regulated and filtered 24 or 12 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.OA auxiliary output with reset for four(4)-wire smoke detectors is available. The 6.5 amp rated supply current can be divided between the four(4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input(input 1 or input 2). In addition, there are common trouble output terminals(NC, C,NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also features "Loop Output"trouble memory indication to help identify troublesome sporatic problems. Model is available in a larger enclosure AL602ULADAJ. Agency Listings • UL Listed Control Units and Accessories for Fire Alarm Systems (UL864), Power Supplies for Fire Protective Signaling Systems (UL 1481). : File# S5075. • CSFM - California State Fire Marshal Approved. File# 7315-1335:103. • MEA -NYC Department of Buildings Approved. • FM Approved. Rots Compliant Features/Specifications �r Power Supply/Charger: • 12VDC or 24VDC selectable output. tnstaHatior CAD Wphacf on Inuctrnns Dia%img Guic • 6.5 amp max total alarm current. • 115VAC 60Hz., 1.45 amp. • Short circuit and thermal overload protection. • Built-in charger for sealed lead acid or gel type battery backup. • Maximum charge current .7 amp. • Zero voltage drop upon transfer to battery backup. Page 2 of 2 • AC input and DC output LED indicators. • AC fail supervision(form "C" contact rated @ 1 amp 28VDC). • Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty. Logic Board: • Class 2 Rated power limited outputs. • Two (2) Class A or two (2) Class B FACP inputs. • Two (2) Class A or four(4) Class B Indicating Circuits. • Two (2) Class B outputs may be paralleled for more power on an indicating circuit. • One (1) Aux. Power Output @ 1 amp supply current(w/Battery Back Up). • Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs. • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. • Horn/Strobe sync protocols include: Gentex , System Sensor*, Faraday, Amseco. • Temporal Code 3 Mode. • Steady Mode. • Input to Output Follower Mode (maintains synchronization of notification appliance circuits). • March Time. • Compatible with 24VDC or 12VDC fire panels. • Common Trouble inputs and outputs. • Ground fault detection. • Lifetime Warranty. Enclosure • Accommodates up to two (2) 12VDC/12AH batteries. • Dimensions: 15.5"H x 12"W x 4.5"D. • 1/2" and 3/4" combination knockouts. Similar Altronix Products AL602UL2ADA 12VDC or 24VDC @ 6.5A max. AL602ULADAJ 12VDC or 24VDC @ 6.5A max. Larger Enclosure. AL802ULADA 12VDC or 24VDC @ 8A max. AL 1002ULADA 24VDC @ l OA max. I I 6160CR COMMERCIAL FIRE ALPHA KEYPAD The 6160CR is an addressable remote keypad intended only when a key is depressed*, or when the system is in for use in commercial fire applications with Honeywell's alarm or trouble condition. control platforms.The keys are continuously backlit for *Note:On some platforms,the LCD may be procrammed to remain on at all convenience and easy visibility. The LCD display is backlit times(see panel instructions for retails). FEATURES • Four programmable • Four LEDs • Large easy-to-read display function keys —Armed —Ready • Red removable door • Built-in sounder —Trouble • Physical —Supervisory 5.250W x7.437"x 7.437" H x 1.312" D SPECIFICATIONS Display Sounder Compatibility •Alphanumeric, 32-character • High-quality speaker •Supports Control Platforms (2 lines x 16 characters) Electrical -VISTA-32FB Rev. 3 and higher LCD back light LEDs: —VISTA-128FB Rev. 4 and higher Armed (red) • 45mA standby 150mA in alarm —VISTA-1 28FBP Ready (green) (sounder, back light and LED on) —VISTA-250FBP `Trouble (yellow) Wiring Table{All keypads) -V1 28FBP-24 *Supervisory (yellow) -V250FBP-24 • See control panel's instructions for DI 'Data IN"to control panel from keypad ULOUL Listed for Residential and Commercial Fire specific applications regarding — Ground(-aux.Power) and Burg installations.To be employed with manufacturer's listed control units as indicated in Trouble and Supervisory LEDs. + +t 2voc(+aux.Power) the installation instructions. ........._.....:_..____._..... ...._._.._.........._._._.____.. DO "Data OUT"from control pane!to keypad ORDERING 6160CR Commercial Fire Alpha Keypad Honeywell Security&Custom Electronics Honeywell Honeywell International Inc. PO Box 9035 Syosset, NY 11791 LueieocR.'o January 2007 www.hone ell.com � 5'2007 H Honeoneywell in ernat:onal inc C > ( $ 5 G)O \ § : Oa, E � / Ev � � O # o \• ' O $ _ } � / \ E / / S � \ aE � e ° 8 \ = t V) § } U f 2 / Ek \ O ) = a ■ _ \ oE / E \ k § § c k \ � 2 3 = E E / E ] mE _ c N Ott $ 5 � _ 0 0 0 § o2 / � 2k kN j / 0 § • 0 \ k 2f ■ \ ul _ » ° 6 0 z 2 0 § E } j ' - Q m e � 0 � 0 � \ \ m 2 .05) / \ % ■ ( f § E 7 § E ■ 6 _ / X § 0 O § / : E § a 2 E 0 c o a Vo = E � 3 o per « ® \ _ � ° EU, \ a/ \ N _ \ Z Cc m Z KEv) = \ /n ) .0c kk E 2 / / \ o au ■ mt § co t 0 \ ■ # 2m � § a4 ' E § E 2 / � Z 7 \ 77 $ / ^ / § ® / 'I ± @ § ° •• 95 • f � e2C ( \ d k00 e = � I O w • 5140MPS-1 Manual Pull Station Ademco 5140MPS-1 Manual Pull Station Features • Aluminum die cast • Key reset and test • Screw terminals • Gold contact SPST • ADA compliant • UL, CSFM, MEA listed and approved II II tl I II PULL Honeywell 5192SD/SDT Addressable Photoelectric Smoke Detector SPECIFICATIONS Diameter(including mounting bracket): 5.5 inches(140 mm) Height(including mounting bracket): 1.7 inches(43 mm) Weight: 5.3 ounces(150 grams) Installation Temperature Range: 32°F to 100°F(0°C to 38°C) Installation Humidity Range: 10%to 93%relative humidity,non-condensing Air Velocity: 4000 ft./min.maximum Heat Sensor(5192SDT only): 135' F fixed temperature electronic thermistor System Voltage Range: 7—14 V Standby Current(maximum @ 12 V): LED off: 1.2 mA LED on: 2.8 mA Before installing detectors, please thoroughly read the supporting Ademco control panel installation instructions, which provide de- tailed information on detector spacing,placement,zones,and special applications.Copies of the installation instructions are available from Ademco. NFPA 72 and NEMA guidelines should also be observed. GENERAL DESCRIPTION The Model 5192SD/SDT photoelectric smoke detector uses a state-of-the-art optical sensing chamber.This detector is designed to provide open area protection and to be used with compatible UL-listed Ademco control panels.An LED on each detector flashes every 10 seconds. If the sensing chamber is unable to detect smoke,the LED will cease to blink.When a unit reports an alarm condition to the control panel,the panel will send a code command to steadily light that unit's LED. If the same loop has multiple detectors report- ing alarm,only the first detector that reported alarm would have its LED turned on steadily. However,the panel will latch the address of all the remaining detectors that reported alarm. The 5192SD/SDT detector is intended for use in an Ademco 2-wire polling loop system. It is addressed by either dip switch or internal serial number and has high and low manintenance that is enabled with dip switch position 8. (NOTE: Maintenance is shipped factory default OFF-dip switch 8 is set to"ON"position).A two-screw,removable terminal block is used to connect to the system. Both detector power and communication between detector and control panel are ac- complished over the same two wires. MOUNTING INSTRUCTIONS Each 5192SD/SDT detector is supplied with a mounting bracket that permits the detector to be mounted: 1.To a single gang box. 2. Directly to a 31,'2 inch or 4 inch octagonal box. 3.To a 4 inch square electrical box by using a plaster ring. TAMPER RESISTANCE This detector includes a tamper-resistant feature that prevents its removal from the base without the use of a tool.To enable this fea- ture, remove the smaller tab by breaking it at the scribed line on the tamper resistant tab on the detector mounting bracket(see Figure 2),then install the detector.To remove a detector from the bracket once it has been made tamper resistant,use a small screwdriver to depress the tamper-resistant tab located in the slot on the mounting bracket,and turn the detector counterclockwise. Figure 1.Surface mounting 5192SD on 31/2 inch Figure 2.5192SD/SDT detector mounting bracket: and 4 inch octagon box: TAMPER RESISTANT TAB TAMPER SLOT (GUT OFF SMALL TAB TO GDEPRESS TAB TO ACTIVATE TAMPER-RESIST /- REMOVE DETECTOR; FEATURE) \, t� �] ARROWStiT S0193-00 S0242-00 AD400-19-00 1 156-1002-011 R Honeywell International Inc.,165 Eileen Way,Syosset,NY 11791 WIRING INSTALLATION GUIDELINES All wiring must be installed in compliance with the National Electrical Code,local codes,and any special requirements of the authority having jurisdiction. Proper wire gauges should be used.The conductors used to connect the smoke detectors to the control panel and accessory devices should le color-coded to reduce the likelihood of wiring errors. Improper connections can prevent a system from responding properly in the event of a fire. The screw terminal block accepts 14 to 22 gauge wire. For best system performance, all wiring should be installed in separate grounded conduit. Do not mix fire system wiring in the same conduit as any other electrical wiring.Twisted pair or shielded cable may be used to provide additional protection against electrical interference. If shielded cable is used,the shield connection to and from the detector must be continuous by using wire nuts,crimping,or soldering as appropriate for a reliable connection. Smoke detectors and alarm system control panels have specifications for allowable loop resistance. Consult the control panel speci- fications for the total loop resistance allowed for the control panel being used before wiring the detector loops.Wire connections are made by stripping about'/4' of insulation from the end of the feed wire, inserting the wire into the appropriate terminal,and tightening the screw to secure the wire in place. NOTE: Using twisted,shielded wire will result in decreased overall cable run as specified in the control installation instructions. INSTALLATION Remove power from the control unit or initiating device circuits before installing detectors. 1. Wire the plug-in screw terminal block(see Figure 3)and plug the terminal block into the detector. 2. Align the arrows on the detector with the arrows on the mounting bracket. 3. Turn the detector clockwise in the mounting bracket until it clicks into place. 4. After all the detectors have been installed,apply power to the control unit or initiating device circuits. 5. Test the detector as described in TESTING. 6. Reset the detector at the system control panel. 7. Notify the proper authorities that the system is in operation. Figure 3.Wiring diagram for 5192SDISDT smoke detector: OPTIONAL CABLE SHIELD 1 1 r I r l r l r l w GND J m J 1<Z Ma wZ 0o Q + + o� H =1 U SWITCH REMOVABLE TERMINAL BLOCK S0215-00 ACAUTION Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. DETECTOR ID NO. IMPORTANT:The 5192 smoke detector provides for both DIP switch and serial number addressing. DIP switch positions 1-7 are used for setting the zone number with older controls which only support DIP switch addressing.The permissible DIP switch addresses are from 10 to 63 as shown in Table 1. If the 5192 smoke detector is to be used with newer controls that support serial number ad- dressing,you MUST configure the detector as a serial number device during the zone programming procedure for those controls.DIP switch addressing of the 5192 with controls that support serial number addressing may result in polling loop trouble conditions. TESTING THE 5192SD/SDT SENSITIVITY NOTE: Before testing,notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service.Disable the zone or system undergoing maintenance to prevent unwanted alarms.Notify the proper authorities that the system is back in operation when finished testing. Detectors must be tested after installation and following periodic maintenance. Both smoke and heat detection testing are recom- mended for verifying system protection capability.Test the 5192SD/SDT as follows: AD400-19-00 2 156-1002-011 R Table 1. Permissible Dip Switch Addresses: DIP SWITCH POSITION DIP SWITCH POSITION DIP SWITCH POSITION Zone Zone one Number 1 2 3 4 5 6 7, 82 Number 1 2 3 4 5 6 7i 82 Number 1 2 3 4 5 6 7, 82 31 ON ON 4 ON O ON ON ON 11 ON N N ON 32 ON ON ON ON ON ON 49 ON ON ON ON 12 ON ON ON ON ON 33 ON ON ON ON ON 5o ON ON ON ON 13 ON ON ON ON 34 ON ON ON ON ON 51 ON ON ON 35 ON ON N ON 52 ON ON ON ON 15 ON ON ON 36 ON ON ON ON ON 53 ON ON ON 16 ON ON ON ON ON ON 37 ON ON ON ON 54 ON ON ON 17 ON ON ON ON ON 38 ON ON ON ON 55 ON ON 18 ON ON ON ON ON 39 ON ON ON 56 ON ON ON ON 19 N ON ON ON 40 ON ON ON ON ON 57 ON ON ON N N 41 ON ON ON ON 58 ON ON ON 21 ON ON ON ON 42 ON ON ON ON 59 - ON ON 22 ON ON N 43 ON ON ON 60 ON ON ON 23 ON ON ON 44 ON ON ON ON 61 ON ON 24 Qj4 Qy ON N ON 45 ON ON ON 62 ON ON 25 ON ON ON ON 46 ON ON ON 63 ON 26 ON ON N ON 47 ON ON SM3 27 ON ON ON NOTES:Blank position=OFF 28 ON ON ON ON 1.DIP Switch position 7 must always be set ON. 29 ON ON ON 2.DIP Switch position 8 disables maintenance signals if ON;enables maintenance signals if OFF. 30 ON ON ON It must be set to ON for all applications except for panels that can support maintenance signals. Failure to do so may result in False Check conditions on the system. 3.Serial Number addressing occurs when DIP switch positions 1-7 are OFF. A. Test Switch 1. Press and hold the recessed test switch, located on the detector housing(see Figure 4),for 5 seconds with a 0.18 inch maximum diameter tool such as an Allen wrench or small screwdriver. 2. An alarm should be annunciated at the system's control or console within 5 seconds. Some systems also cause the detec tor's LED to latch on during the alarm.Otherwise,the LED continues to blink every 10 seconds. B. Test Module(Model No.MOD400R) The MOD400R test module can be used with a DMM or analog voltmeter to check the detector sensitivity as described in the test module's manual. C. Auto-maintenance Feature Test sensitivity from the control panel if applicable(refer to control panel test procedure). D. Smoke Entry Test The recommended field test tool is the GEMINI model 501 aerosol generator set to represent 4%/ft.to 5%/ft.obscuration as de- scribed in the Gemini manual. Using the bowl-shaped applicator,apply aerosol until detector alarms. E. Direct Heat Method(5192SDT only) Direct the heat from a 1000 to 1500 watt hair dryer toward either of the thermistors. Hold the heat source about 12 inches from the detector in order to avoid damage to the plastic.Heat detectors that go into alarm reset only after they have cooled sufficiently.Check the control panel to determine whether the Reset switch,or other auxiliary device or control momentarily interrupts loop power. Detectors that fail to alarm during any of the above tests should first be cleaned as outlined in MAINTENANCE.If the detector still fails to activate, return it for repair. Figure 4.Top and side views showing test switch location LED \\ TEST MODULE 1 / PUSH RECESSED SOCKET SWITCH WITH A RECESSED TEST 0.18"MAX.DIAMETER TOOL' �._ SWITCH S0155-00 S0206-00 ACAUTION Dust covers are an effective way to limit the entry of dust into smoke sensing chambers. However,they may not completely prevent airborne dust particles from entering the detector.Therefore,Ademco recommends removal of detectors before beginning construc- tion or other dust producing activities. Be sure to remove dust covers from any detectors left in place during construction as part of returning the system to service. AD400-19-00 3 156-1002-011 R AUTO-MAINTENANCE FEATURE Figure 5.Removal of cover and screen for cleaning: This detector can transmit a LOW SENSITIVITY or HIGH SEN- SITIVITY signal in addition to the basic normal and alarm levels. These HIGH and LOW SENSITIVITY signals are communicated to the control panel and indicate that the detector may not be able REMOVABLE to detect smoke or may false alarm.Supporting control panels use HOUSING these maintenance signals to effect prompt cleaning or replace- ment of the malfunctioning detector,which is uniquely identified at the control panel by the detector's polling address.The auto-main- REMOVABLE tenance feature may be enabled by placing dip switch position#8 t SCREEN to the"off"position.This may be necessary to be compatible with some panels. Refer to Ademco control panel installation instruc- tions to determine if maintenance features are supported. SENSING CHAMBER MAINTENANCE Li Li H Ii U U LI COVER NOTE: Before removing the detector, notify the proper authori- ties that the smoke detector system is undergoing maintenance SENSING and will temporarily be out of service.Disable the zone or system I IfIjII --- CHAMBER undergoing maintenance to prevent unwanted alarms. NOTE: (Model 5192SDT only) Before removing the detector _ E BASE cover, note the position of the thermistors. Make sure the therm- S0156-00 istors are not bent over when the housing is replaced. 1. Remove the detector housing by gently prying the four hous- 5. Replace the chamber by orienting it so that the arrow on the ing tabs on the bottom of the base with a small-bladed screw- top aligns with the arrow on the printed circuit board. Care- driver and pull the housing from the base. Use caution to fully press the screen on to the sensing chamber, making avoid damaging the thermistors(5192SDT only). sure it fits tightly. 2. Vacuum the screen carefully without removing it. 6. Replace the housing by aligning the three triangular slots on 3. Remove the screen assembly by pulling it straight out (see the base with their counterparts on the housing.Gently press Figure 5). Remove chamber cover, the housing until it locks in place. Check to make sure the 4. Clean the sensing chamber by vacuuming or blowing out thermistors are in the upright position(5192SDT only). dust and particles. 7. Reinstall the detector. 8. Notify the proper authorities that the system is back in operation. Please refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Honeywell International Inc.,acting through its Security&Custom Electronics business("Seller")165 Eileen Way,Syosset,New York 11791,warrants its product(s)to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s)or,for product(s)not having a manufacturer's date stamp,for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period,in which case the shorter period shall apply.Seller's obligation shall be limited to repairing or replacing,at its option,free of charge for materials or labor,any product(s)which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service.Seller shall have no obligation under this Limited Warranty or otherwise if the product(s)is altered or improperly repaired or serviced by anyone other than Honeywell factory service.Connection of any device(s)to a communicating bus of a Honeywell security system(e.g.,keypad bus,polling loop)other than those manufactured or approved by Honeywell shall void this warranty. For warranty service,return product(s)transportation prepaid,to Honeywell Factory Service, 165 Eileen Way, Syosset,New York 11791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHER- WISE,WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY,EXPRESS OR IMPLIED,OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER,EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s)it sells may not be compromised or circumvented;that the product(s)will prevent any personal injury or property loss by burglary, robbery,fire or otherwise;or that the product(s)will in all cases provide adequate warning or protection.Customer under- stands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery,fire,or other events occurring without providing an alarm,but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S)FAILED TO GIVE WARNING.HOWEVER,IF SELLER IS HELD LIABLE,WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE,REGARDLESS OF CAUSE OR ORIGIN,SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S),WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. AD400-19-00 4 156-1002-011 R ©2005 Honeywell International Inc. SYSTEM SENSOR 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire,and for non-life-safety installations where smoke detectors are inappropriate. , � m Features Multiple configurations.The 5600 series offers a full-I ne o' •Multiple configurations for insta iat ons: configurations to accommodate a broad range of applications Both Singe and dual crcuit models sngle and dual-circuit models are available for bow-and high- Fixed temp and comb.nation fixed-temp/rate-c'-.rise temperature ratings with either fixed tem;cererute or tomb ra icr 135F or 190'F ratincas. fixed temperature/rate-of-rise(FOR)actuation The ROR element of me fixed/ROR model is rerrorable to accommodate field t stilq. •Plain housing for residential installations(Mode!5601 P) •Easy-to-use terminal screws Installation flexibility. o satisfy a variety of installation needs, •A broad range of back box mounting options: tie 5600 series easily mounts to single-gang and-octagonal back —Single gang boxes,And these models accommodate four-square back boxes; —3.5""and ?""Octagonal when used with a square to round plaster ring.Tne reversible —4 square with square*o ro,ird plaster ring mounting bracket pe,mits both t°ush-and sur`ace-mount back box installations. •Reversible•nount:ng bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric c'r,sarac-:ers identify the activation rnetood,as well as the temperature rating,in Fahrenheit and(lelsus degrees. Fixed temperatue models are dentified FX,while combination fixed/rate-off-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.Woe's the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings c≥ ≤≥ PPOVd Specifications Mechanical heat detector shall be a System Sensor 5600 series mode number_ ,listed to UndEl w iters'_aberato ies UL 521 for Heat Dee'ors:o Fire Protective Signaling Systems.The detector steal be either a single circuit or a dual circuit type,normally open:.The detector shall be rated for activation at either (57 r)or 1 a4 F 140°C),and,hall activate by means ofa 5xed ternperat.ne thermal sensor,or a combination fixed temperarure/ran o rise ihemal sensor. The rate-of-rise element shall be activated by a'apid risen in temperature,apprcx mately 1:°F(8.3°C)per mirute.The detector shall include a reversib!e mounting bracket for mounting to 3% non and 4-inch octagons'',single gang,and 4-inch square back boxes with a square to round piaster rirc.Wr inn connections shall be made by means of 14145 screws that shall accommodate 14-22AWO vine,The detector shall contain alphanumeric markings on the exterior of the"sousing to identify its temp_ratu'°tt ng and:x ti v,-ncr in_thr.c--The ate o!-rise element of con,bin u lion fixes temperature/rate t-rise model shall be re�to-able,to allow Ia cclx tesurig, he detectors shall include an external collector that shall droo upon activation to identify t le unit in alarm. Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°[(38°C) -- -- 5602,56(k1,5622,and 5624:150°F(65.6°C) Operating Humidity Range 5 to 95%Rb non-condensing Dimensions with mounting bracket Diameter:4.57nches(1(.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P.5603,562',and 5623:135°F(57`C) 5602,5604,562.2,and 5624:194°F)90°C) Weight 60z.((70 grams) Rate-of-Rise Threshold 15°F(8.3°C) is per minute(models 5601 F?5602,5621,and 5622 only) Mounting 3Yrin_n octagonal back box — -- 4-iinxi)nrtaconal back box Single gang back box 4-i;ich square back box with a sr uare to round plaster ring Operating Voltage/Contact Ratings 6-1 25./AC/34 6 28VDC/':A 125VDC/03A 250\/DC'0 1 A inputTerminals 14-22 A'4rG QQQ Ccx 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information 5601 P Single None 135°F(57°C) Fixed Temperature!Rate-of-Rise 50 feet x 50 feet((5.24m x 15.2m) 5602 Single etcerina 9=°F(90'41 fised Temperature/Rate ofRise 50 feet x 50 feet t 15.24w x-5.2m) 5603 Single etterin g 1351-(5714) Fixed 7ernper,t.;re 25 feet x 25 feet(7.62n x%r 2m' 5604 Single Lettering 194`F(90°C) nixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dua, -tittering 115°f)57°C)"C) xed tempera!;re/Rase of-Rise 50 feet x 50 fcerr(5.24m x(5.7n a 5622 Dua' Lettering 194°F(90°C) Fixed Temperature;Rate-of-Rise 50 feet x 50 feet)'5.24m x i3.2rn) 5623 Dual Lettering 135°F((57°C) Fixed Temperature 25 feet x 25 feet)/.62m,e7 62m 5ii24 Dear etiering 194°) 00°C) `ixej Temperature 25 feet x25 feet('52rn x 7.62m; NOTL:Refer to NF0A72 cuide-in es'or;pacing red ctions when ceiling he grits.exceed"0 feet. SYSTEM 3d'S 4)'110 Avenue P51.Charles n 74 .•,oaf: f = $ SENSORnr F'1 r e:8J0 SEN�JR2 Fax:634 3,/u4S5 r', � SYSTEM $ SENSORR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRIert Features The SpectrAlert Advance series of notification appliances is Electrically compatible with existing SpectrAlert products designed to simplify installations,with features such as plug in •Automatic selection of 12-or 24-volt operation at 15 and 15/75 designs,instant feedback messages to ensure correct installation of candela individual devices,and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. •Plug-in design •Field selectable candela settings on wall and ceiling units:15,15/75, When installing Advance products,first attach a universal mounting 30,75,95,110,115,135,150,177,185 plate to a four-inch square,four-inch octagon or double-gang •Same mounting plate for wall-and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang •Shorting spring on mounting plate for continuity check before junction box. installation Next,connect the notification appliance circuit wiring to the SEMS •Tamper resistant construction terminals on the mounting plate. •Outdoor wall and ceiling products rated from—40°F to 151'F •Design allows minimal intrusion into the back box Finally,attach the horn,strobe or horn/strobe to the mounting plate •Horn rated at 88+dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Rotary switch for horn tone and three volume selections mounting plate's terminals.The device will temporarily hold in place Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) with a catch until it is secured with a captured mounting screw. outdoor requirements •Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification Compatible with MDL sync module appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. swraws MEA 0043$-1653 187(indoors[mob F M 73653187 fond/(oudoo,4rabs5) :®� 71)$-1653:188(horn/probes. approved chime/strobes) LISTED APPROVED 7135-1653189 ihoms,chime,) 5401 3023572 M[8632-05-E 55512 53353 SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box or double-gang back hox.Two-wire products shall also mount to a single-gang 2 x 4 x 17/a-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 01 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115135,10,1 15,135,150,1 7/,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair or wires.the module shall mount to a 411,6 x 411/,6 x 21/s-inch back box.The module shall also control two Style S'(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°U K Series Operating Temperature —40°F to 151"F(-40`C to 66"C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 120C/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8 diameter x 2.5 high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5"D(142 mm Lx 119 mm W x 64 mm D) Horn dimensions 5.61x4.7Wx1.3"D(142mmLx119mmWx33mmD) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0W x 2.2D(151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1-diameter x 2.25 high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1 W x 2.0D(145 mm Lx 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Wall-mount trim ring dimensions(TR-HS,TRW-HS) 5.7"L x 4.812 W x 0.35"D(146 mm Lx 122 W mm x 9 D mm) Ceiling-mount trim ring dimensions(TRC-HS,TRCW-HS) 6.9"diameter x 0.35 high(176 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. ACS-0As-NS UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DCtnput 15 15/75 15 15/75 30 75 95 110 115 temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 2'6 Non-temporal low 132 154 80 90 105 161 184 202 211 III 16-33 Volts 16-33 Volts DCtnput 135 150 177 185 FWR Input 135 150 177 185 temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela ratings must be reduced in accordance with this table. S, � I, ■ 8-17.5 16-33 24 Volt Nominal Listed Candela Candela rating at-40°F Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 /0 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 7r Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 /8 85 85 90 90 97 98 150 150 9 Coded Low 75 75 81 81 38 85 % 92 177 177 'Settings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 Aa5-0395w5 SpectrAlert Advance Dimensions 4.7' 2.5" 6.8' 5.6" Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1' 12.25'1 A. Die. r— °5"---t 5�-.1 x«2.231 ( 9p 0 0 U 1ci o o d I.--5.1'-./ Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn/Strobes Ceiling Hom/Strobes(cont'd.) P2R*t 2-wire Horn/Strobe,Standard cdt,Red PC4W 4-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P2RK*' 2-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P2WH* 2-wire Horn/Strobe,High cd,White SCRK' Strobe,Standard cd,Red,Outdoor P4R* 4-wire Hom/Strobe,Standard cd,Red SCR'HK' Strobe,High cd,Red,Outdoor P4RH* 4-wire Horn/Strobe,High cd,Red SCW*t Strobe,Standard cd,White P4RK" 4-wire Horn/Strobe,Standard cd,Red,Outdoor SCWH*t Strobe,High cd,White P4RHK' 4-wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Horn/Strobe,Standard cd,White HR Horn,Red P4WH* 4-wire Horn/Strobe,High cd,White HRK° Horn,Red,Outdoor Wall Strobes HW Horn,White SR*- Strobe,Standard cd,Red Accessories SRH*` Strobe,High cd,Red BBS-2 Back Box Skirt,Wall,Red SRI' Strobe,Standard cd,Red,Outdoor BBSW-2 Back Box Skirt,Wall,White SRHK Strobe,High cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red SW* Strobe,Standard cd,White BBSCW-2 Back Box Skirt,Ceiling,White SWH* Strobe,High cd,White TR-HS Trim Ring,Wall,Red Ceiling Horn/Strobes TRW-HS Trim Ring,Wall White PC2R* 2-wire Horn/Strobe,Standard cd,Red TRC-HS Trim Ring,Ceiling,Red PC2RH* 2-wire Horn/Strobe,High cd,Red TRCW-HS Trim Ring,Ceiling,White PC2RK' 2-wire Horn/Strobe,Standard cd,Red,Outdoor Notes: PC2RHK' 2-wire Horn/Strobe,High cd,Red,Outdoor *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g., PC2W*t 2-wire Horn/Strobe,Standard cd,White P2R-P PC2WH*t 2-wire Horn/Strobe,High cd,White t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. #"Standard cd,"refers to strobes that include 15,15/75,30,75,95,110,and 115 PC4R 4-wire Horn/Strobe,Standard cd,Red candela settings."High cd,"refers to strobes that include 135,150,177,and 185 PC4RH 4-wire Horn/Strobe,High cd,Red candela settings. PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor All outdoor units ending in"K"include a weatherproof back box. PC4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor D Add"-R"to model number for weatherproof replacement device(no back box included). t\,$ JI.71 l r/ e2008SysI*ms.no, �`� e D 3825 Ohio Avenue•St.Charles,IL 60174 a°a Rsve"4 o ss blen oaa°9e °.°«!°ev,"tsystrrnse°sorromr°, t\, 5 NSOA Phone:800-5ENSOR2•Fax:630-377-6495 ��^*^�P'od°a'^ro aro, a°a°9meiacesr"�,o rm"eaaaeec A05-0395-005.5,09--2018 DTK-MRJ31XSCPWP Alarm Dialer Surge Protection General Product Specifications DITEK's MRJ31XSCPWP protects fire and security system dialer circuits. This point of use surge protector can be easily installed in-line. DTK-MRJ31 XSCPWP Product Features • Protects dialer circuit • RJ31X connection with external grounding screw DTK-MRJ31XSCPWP • Multi-stage, hybrid design provides the best possible protection •Automatic reset to protect against repeated surges Specifications Performance Data Agency Approvals:UL497A Service Connection Method: RJ31X In/Out, 8 pins Voltage MCOV Max Continuous Current: 150 milliamps DTK- <105V AC 130V AC Peak Surge Current:: 9,000 Amps MRJ31XSCPWP Protection Modes: Pin 4—Ground, Pin 5—Ground Operating Temperature: -40°F - 158°F (-40°C - 70°C) Maximum Humidity: 95% non-condensing Dimensions: 1.7" x 3.0" x 1.2" (43mm x 76mm x 30mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty 1iio1 (1;) 9001-2000 QED One DITEK Center 1-800-753-2345 Direct: 727-812-5000 Doc. Number: SPS-100065-001 Rev 2 6-08 1720 Starkey Road Technical Support: 1-888-472-6100 ©2008 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change DTK-HW Series Equipment Pane//Dedicated Circuit Surge Protector Genera/Product Specifications DITEK's HW series of surge protection are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit . loads. DTK-120HW DTK-120/240HW +m DTK-240HW Product Features UL • Diagnostic LED indicates ground presence, system Model 1449, power and SPD function Selection: System 2n°Ed. •Small footprint enables installation in a variety of DTK- Voltage MCOV S.V.R. locations 120HW 120VAC 130V 400V •Available for popular 120V, 120/240V and 240V single-phase systems 120/240HW 120/240VAC 130V/250V n/a •Ten Year Limited Warranty 240HW 240VAC 250V n/a Specifications Agency Approvals: UL 1449,2nd Edition 2007, cUL (DTK-120HW) IEEE Location Categories: Cat.A&Cat. B 1 .X 1" Suppressor Type: Parallel configuration, external mount Peak Surge Current: 22,500A(DTK-120HW) - 27,000A(DTK-120/240HW) 13,500A(DTK-240HW) h Z( LO Protection Modes: L-G, L-N, N-G Temperature Range: -40C to+85C Operating Frequency: 0Hz-400Hz reH Dimensions: 2.9"x 1.6"x 2.1" (73.7mm x 40.6mm x 53.3mm) Weight: .51b. (227g) j Housing: NEMA 4 ABS iso P \ l 9441-2004 ! C UL uS One DITEK Center 1-800-753-2345 Document:SPS-1 00057-00 1 Rev 3 08/08 1720 Starkey Road Technical Support:1-888-472-6100 ©2008 DITEK Corp. Largo,FL 33771 www.ditekeorp.com Specification Subject to Change