Loading...
HomeMy WebLinkAbout08-8645 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8645 FIRE ALARM SYSTEM PERMIT Permit Number: 8645 Address: 7910 GALL BLVD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-00700-0000 Improv. Cost: 98,000.00 Date Issued: 12/17/2008 Name: PRIMERICA GROUP ONE Total Fees: 200.00 Address: 3629 MADACA LANE Amount Paid: 200.00 TAMPA FL 33618 Date Paid: 12/17/2008 Phone: (813)933-0629 Work Desc: INSTALLATION FOR FIRE ALARM-STAPLES STORE FIRE ALARM&SECURITY TECHNOLOGI FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 100.00 FIRE INSPECTION FEES 50.00 FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRACTOR SIGNAfUIE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 Zephyrhills Fire Rescue 6907 Dairy Road,Zephyrhills,FL 33542 Fire Marshal Bus(813)780-0041 Kerry Barn ett Fax (813)780-0044 E-mail: kbamett@fire.zephyrhills.fl.us Plan Review#: 08-166 Project: Staples Number of Pages: 1 plus details packet w/calcs Date: December 15,2008 I have received and reviewed the revised plan for the fire alarm located at 7910 Gall Blvd and will allow this project to move forward. Payment for permit contractor acknowledges agreeing with items below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Installation shall be in compliance with NFPA 72,2007 edition. 2. Breaker shall be locked off and marked. 3. Devices shall be addressable. Pulls,ducts, and smokes shall be addressed and labeled as such to correspond with panel(example: Bathroom area smoke detector of rear door pull). 4. Strobes shall remain on when system is silenced. 5. Zone map shall be located by alarm panel. 6. Phone jacks shall be marked. 7. Batteries shall be labeled. 8. Leave extra pull box key w/alarm panel. 9. Copy of certificate of UL Listed Central Monitoring Company shall be provided to Fire Marshal at acceptance test Inspections Required: 1. Acc T st KE T, FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a fuel approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. FIRE SERVICE USER FEES Occupancy No.: / Contractor: 7' i'!� s't Business Name: Billing Address: Business Address: 7 io Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE eSite Plan N/C Annual N/C Sprinkler $50 let Alarm WC Mufti-FamiWCommercial .06 sf let Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas 6th Alarm $200 0-2S Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 Per Riser $50 Hydrostatic Test $65 per system, Fire Works $500 FIRE PUMP Acceptance Test $45 per system Camp Fire $25 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 25 Devices FIRE ALARM SYSTEM Place of Assembly $50 Annual 26 plus Devices $100 iZJsysteni Acceptance Fire Protection $25 SUPPRESSION SYSTE Recall Acceptance Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wall/Smoke WaN $15 per wan Generator<KW $100 CO2 $50 LP Gas $25 pertank Generator>30 KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Tent 10x10 or greater $15 per tent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Annual LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 [J Natural Gas Installation $50 Re-Inspection DBL (Per System) (other than annual) Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours 8 Construction insp. N/C Emergency Vehicle A0 $50 ✓ FALSE ALARM PLANS TOTAL I/ ) INSPECTION TOTAL PERMIT TOTAL____ TOTAL L_____ GRAND TOTAL r SOD 1 Comments: Date: CJ� Inspctor: 4' ////f� /2 (.__- N0Y/20/2007/TUE 11 :54 AM ZEP 1LL5 BU DI � .No, 813-780-0021 P. 001/001 813-7,80-0020 ` '� of.ZephyrhlUS'r-lr Fex-813-780-0021 :IS - Permit ApplIcation Y i Phone Contactfor•Permit Date Received owners Neme M ro, C) rrl(- .Owners Phone Number .I1i i igI owners Address LcAs < ff)Jflf FL Lo(B pee Simple Titleholder Name t S [fir • O Y1 — ' Titleholder Phone Number Fee Simple Titleholder Address n 600 i 1 Vd Vll( J r Lot# Job Address . 3S-zS-21—pp►o—o-t —0'tDO� Sub Division 1 5A ' CITi ,.tt Parcel# Sic-Hazard Waste Storage-ANNUAL ' [jJ Fumigation Tent - Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier I1 or RQ Facility)ANNUAL �. Hood Installation _. M LD Controlled Bum �'1I t l/t( Emergency Generator- 30 kw LP/Nawral Gasanstalietion • Emergency Generator 30 kw LP/Natural Gas-ANNUAL Sale Tim• ' FIre.Protection Maintenance-ANNUAL Pieces of Assembly-ANNUAL S{ • � cm � ar • Sprinkler 0 ❑ 0 ' " a Recreational Bum wry) • Fire Alarm ❑ la ' ❑ T ] a Sparklers Hood Cleaning p [7 . O O 1111 1I1. Sprinkler System Installations Hood Suppression O :❑ • ❑ . •U Standplpee(Sprinkler Sys) Fire Alarm Installation a Torch Roolingtlar Kettle Fire Pumps Waste Tire Storage ANNUAL ' Fire Works ' Flammable Application-ANNUAL O j Valuation of Protect Fuel Tanks ' Other: Contractor Company ff1tY rvr Signature Registered N Fee Current ' N Address — U4QUcense#; ELECTRICIAN Company Signature Registered Y/NJ Fee Current I Y/!1 Address _j . License# PLUMBER Company . • Registered Y'/N Fee Current• LY I N Signature Address 'Llcenee . • O MECHANICAL Company Signature S , Registered Y/N • Fee Current Y'I N Address •License# ' • OTHER Company Signature . Registered I V/NJ Fee Current :Y/N ' Address License# . Directions:. ' Fill out application completely. Owner&Contractor sign.back of application;notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement Is requlred,(Mechanlcal work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10.14 days for review after submittal date, Parcel#-obtained from Property Tax Notice(http:/lappreiser.paacogov.com) . 1 Fire Alarm & Security Technologies State Fire Alarm License # EF 20000480 www.fastdetection.com Project Staples Zephyr Commons Kossik and US Highway 301 Zephyrhills, FL Equipment Supplier Fire Alarm& Security Technologies 27251 State Rd. 54 Suite B-14/331 Wesley Chapel, FL 33543 SUBMITTED PLAN(S)HAVE BEEN REVIEWED BY ZEPHYRHILSSHAL'S OFFICE Date: Reviewer: Contact Tim Sorvillo 813-690-4104 27251 State Road 54 Suite B-14/331 Wesley Chapel, FL. 33543 June 17,2003 DF-52293•Al-250 MS-9200OD • Fire•LITe®ALarms Intelligent Addressable FACP with Built-In 14.4K Baud Modem www.firelite.com Section:Addressable GENERAL California State Fire The Fire•Lite MS-9200U0 is a compact,cost-effective,intelli- U� Marshal gent addressable fire alarm control panel with a capacity of p 7165-0075:208 198 addressable Fire•Lite devices on one Signaling Line Cir- cuit(SLC)and a built-in 14.4K Baud modem for remote site LISTED uploadidownload or remote monitoring- S624 The Signaling Line Circuit (SLC) loop supports up to 99 addressable detectors including photoelectric,photoelectric with heat,ionization,photoelectric duct,fixed heat,fixed heat with rate-of-rise, and fixed high-heat detectors. It also sup- ports up to 99 addressable modules including monitor(two- wire detector, normally open devices), dual-monitor func- tions(two monitor circuits from one module,two addresses used),control(for Notification Appliance Circuits),and relay (two Form-C)modules.The panel uses surface-mount tech- nology and is designed for ease of installation,programming, and maintenance.It features the latest in advanced fire pro- tection technology, including maintenance alert and auto- matic detector test functions_ SPECIAL FEATURES: • Built-in 14.4K Baud modem. • Selectable strobe synchronization per NAC. • Remote site upload/download. • Four Class B or two Class A NAC circuits. FEATURES SLC Loop: • SLC can be configured for NFPA Style 4, 6, or 7 opera- tion. • SLC supports up to 198 addressable devices(99 detec- • Remote site upload/download capability. tors and 99 monitor, control,or relay modules), including • Two level user-programmable passwords. the new addressable dual-monitor module, heat detec- • Custom English labels (per point) may be manually en- tors, and duct detector. tered or selected from an internal library file. • SLC loop maximum length 10,000 ft.(3,048 m)@ 12 AWG • Two programmable Form-C relay outputs. (3.25 mm').Requires twisted,shielded wire(3,000 ft./914.4 • 99 software zones. m untwisted, unshielded wire). User Interface: Notification Appliance Circuits(NACs): • Built-in 14.4K Baud modem (DACT). • Four onboard NACs with additional NAC capability using • Remote Acknowledge,Silence,Reset and Drill via addres- output control modules(CMF-300 or CMF-300-6). sable monitor modules,ACS Series annunciators or LCD- • Silence Inhibit and Auto Silence timer options. 80F remote annunciator. • Continuous,March Time,Temporal or California code for • EIA-232 printer/PC interface(variable baud rate)on main main circuit board NACs with two-stage capability, circuit board. • Selectable strobe synchronization per NAC. • Integral 80-character LCD display with backlighting. • 6.0 amps total NAC power with XRM-24. Real-time clock/calendar with automatic daylight savings Advanced Fire Technology: adjustments. • Sensitivity testing with printable results, onsite or offsite. • History file with 1,000-event capacity. • Automatic drift compensation. • EIA-485 supporting up to 32 ACS Series annunciators. Programming and Software: • EIA-485 supporting up to 32 LCD-80F annunciators. • Autoprogram (learn mode)reduces installation time. • Maintenance alert warns when smoke detector dust ac- - Fully programmable from local keypad, local PS-2 key- cumulation is excessive. board or PC via PK-Plus Windows®utility. • Automatic device type-code verification. cont'd pg.3 This document is not intended to be used for installation purposes.We try to '�O 9001 f keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are sub- ject to change without notice. For more information, contact Fire Lite Alarms, ; One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, ENCINEEIINA II MANOFAC(IIING Made in theev uhs. Toll-Free FAX:(877)699-4105. DF-52293 06/17/03 — Page 1 of 4 EIA-485 INTERFACE 24 VDC (DIM-485)built into .. the motherboard "•' _ (four wires) SMOKE DETECTORS SD350,SD350T,CP350,- IILCD-80F SD355,SD355T,CP355 Up to 6,000 ft.(1825.8 m) Optional between each LCD-80F REVERSE in the EIA-485 loop,and POLARITY/ between each LCD-80F CITY BOX and the FACP HEAT OUTPUT DETECTORS (4XTMF) H350,H350R, H355,H355R t 124 VDC CIE= EIA-485 8 FORM-C,5-AMP RELAYS ■ . in ACS mode (optional,order ACM-8RF) ■ ■ (two wires) DUCT DETECTORS . ■ D350P,D350RP NACs(Notification Appliance Circuits) °iijij° ANNUNCIATORS BELLS,SIGNALS,STROBES B AFM-LED,LDM, EIA-232 G ACS/ACM INTERFACE p° °O (PIM-24)built into MONITOR the motherboard MMF-300,MDF-300, MMF-302,CMF-300, CRF-300,1300 PRINTER NOTE:System can use either MINI MONITOR the printer OR the LCD-80F MMF-301 They cannot be used simultaneously ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6; CMF-300-6, C:RF-300-6 WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit operation.It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG(0.75 mm2)and no larger than 12 AWG(3.25 mm2). The wire size depends on the length of the SLC circuit. Use the t • table below to determine the specific wiring requirements for the SLC_ PULL STATION BG-12LX Wire Distance Typical Wire Size 5'2932'wmI Requirements in Feet(m) 10,000 feet 12 AWG(3.25 mm2):Belden 9583,Genesis 4410, Twisted pair,shielded (3,048 m) Signal 98230,WPW D999. Twisted-pair,shielded 8,000 feet 14 AWG(2.00 mm2)'.Belden 9581,Genesis 4408, (2,438 m) Signal 98430,WPW D995. Twisted-pair,shielded 4,875 feet 16 AWG(1.30 mm2):Belden 9575,Genesis 4406 (1,486 m) and 4606,Signal 98630,WPW D991. Twisted-pair,shielded 3,225 feet 18 AWG(0.75 mm2):Belden 9574,Genesis 4402 (983 m) and 4602,Signal 98300,WPW 0975. Unwisted,unshielded 3(0,05 ffejt 12—18 AWG(3.25—0.75 mm2). " ---"- - ---- 5229311 N Page 2 of 4 — DF-52293•06/17/03 • One person audible or silent walk test with walk-test log NFPA STANDARDS and printout. The MS-92000D complies with the following NFPA 72 Fire • Point trouble identification. Alarm Systems requirements- • Local piezo sounder. • LOCAL(Automatic,Manual,Waterflow and Sprinkler Su- • Waterflow(nonsilenceable)selection per monitor point. pervisory)- System alarm verification selection per detector point. • AUXILIARY(Automatic,Manual and Waterflow)(requires • 4XTMF). PAS (Positive Alarm Sequence) and presignal delay per REMOTE STATION (Automatic, Manual and Waterflow) point(NFPA 72 compliant). re uires 4XTMF). city box transmitter). Optional 4XTMF module (conventional reverse polarity/ • PROPRIETARY (Automatic, Manual and Waterflow). • CENTRAL STATION(Automatic,Manual and Waterflow. CONTROLS AND INDICATORS and Sprinkler Supervised). LED INDICATORS SPECIFICATIONS 1 AC POWER (green) 2. FIRE ALARM(red) AC Power—TBI: 120 VAC, 60 Hz, 3.0 amps. Wire size: 3. SUPERVISORY(yellow) minimum 14 AWG (2.00 mm2)with 600 V insulation. 4. ALARM SILENCED(yellow) Battery(lead acid only)—TB2:Maximum charging circuit: 5. SYSTEM TROUBLE(yellow) Normal flat charge 27.6 VDC @.80 amp.Maximum battery 6. MAINTENANCE/PRESIGNAL(yellow) charger capacity: 18 AH. MS-9200OD cabinet holds maxi- 7. DISABLED(yellow) mum of two 18 AH batteries.For 25- 5—�120 20A and BB-55F r ,use 8- BATTERY FAULT(yellow) the CHG-120F or CHG-75 Battery 9 9. GROUND FAULT(yellow) Battery Box. MEMBRANE SWITCH CONTROLS NOTE:Jumper JP3, on the FRCP main circuit board, must 1 ACKNOWLEDGE/STEP be cut to disable the FRCP battery charger when using the 2. ALARM SILENCE CHG-120F. 3. DRILL Remote Synchronization Output - TB2: A 24 VDC, 40 4. SYSTEM RESET(lamp test) mA signal that mimics the sync signal of NAC 1 and can be 5—16. 12-key pad with full alphabet utilized by remote power supplies such as the FCPS-24FS6/ 17—20. 4 cursor keys 8.This allows NAC devices attached to the power supply to 21 ENTER synchronize with the devices connected to NAC 1 of the FIELD-PROGRAMMING FEATURES FACP. OFFLINE PROGRAMMING: Create the entire program in Communication Loop — (standard) TBB: 24 VDC nomi- your office using a Windows®-based software package(or- nal,27.6 VDC maximum.Maximum length. 10,000 ft.(3048 der programming kit PK-CD,containing PK-Plus,separately). m) total twisted, shielded pair length. Maximum loop cur- Upload/download system programming locally to the MS- rent: 400 mA (short circuit)or 100 mA(normal). Maximum loop resistance: 40 ohms- Supervised and power-limited. 92000D in less than one minute. AUTOPROGRAMM/NG Command the MS-92000D to pro- Notification Appliance Circuits—TB4: Power-limited cir- cuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal gram itself (takes less than 30 seconds). In the Auto-Pro- operating voltage:24 VDC.Current limit:fuseless,electronic, gram mode,the MS-92000D scans for all possible devices power-limited circuitry. Maximum signaling current per cir- at all addresses, stores the device types, and addresses cuit:2.50 amps. End-of-Line Resistor:4.7K ohm, 112 watt found,and then loads default values for all options(General (PIN 71252 UL listed)for NACs. Refer to Fire•Lite Device Alarm). It also checks for two or more devices set to the Compatibility Document for listed compatible devices. same address. Programmable and Trouble Output Relays—TB5, TB6, ONLINE EDIT:While still providing fire protection,the MS- T67: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 92000D may be programmed from the front panel. Simple amps @ 30 VAC (resistive). Form-C relays. menu trees displayed on the LCD allow the trained user to Four-Wire Resettable Smoke Detector Power (24 VDC perform all functions without referring back to the program- nominal)—TB1,Terminals 3(+)&4(—): Maximum ripple ming manual. voltage: 10 mVRMs. Up to 0.5 amps for powering four-wire ENGLISH LABEL LIBRARY: Quickly select labels from a smoke detectors. Power-limited circuit. Refer to Fire•Lite standard library of more than 50 adjectives/nouns, such as Device Compatibility Document for listed compatible devices. "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Nonresettable Power#1 (24 VDC Nominal)—TB1,Termi- Use recall function to repeat previously used label. nals 3(+)&4(—):Maximum ripple voltage.10 mVRMS.Up to PROGRAM CHECK: Automatically catch common errors, 0.5 amps total DC current available from each output.Power- such as control modules not linked to any zone or input point, limited circuit. TBI, as reset.TB Terminals4 V non-resettable via JP4 e config- ured MAINTENANCE ALERT NOTE:If using optional XRM-24,total NAC and auxiliary cur- The MS-9200OD continuously monitors each smoke detec- rent draw cannot exceed 6 amps. for and is capable of reporting maintenance conditions.This EIA-485(ACS)-TB6: ACS annunciator connector,Termi- reduces the risk of false alarms due to dust accumulation. nal 1 (+)and Terminal 2(—). Refer to the control panel installation manual for more infor- EIA-485 (TERM) — TB?: Terminal mode annunciator con- mation. nector, Terminal 1 (Out+), 2 (In +), 3 (Out—), 4 (In—). AUTOMATIC TEST OPERATION EIA-232 — TB8: PC/printer connector, Terminal 1 (Trans- mit), 2 (Receive), 3 (DTR), 4 (Ground). The MS-92000D performs an automatic test of each detec- tor every two hours.Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. DF-52293-06/17/03 — Page 3 of 4 CABINET SPECIFICATIONS directlytoa4.0"(10.16cm)electrical box.Notification Appliance Door: 18.67" (4743 cm) high x 15.78" (40.08 cm) wide x Circuit option requires external 24 VDC to power notification 1.08" (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x appliances. 15.50" (39.37 cm)wide x 4.37" (11.1 cm)deep. Trim Ring CRF-300: Addressable relay module containing two isolated (FC-TR): 21.62" (54.92 cm) high x 18.62" (47.3 cm)wide. sets of Form-C contacts, which operate as a DPDT switch. PRODUCT LINE INFORMATION Mounts directly to a 4.0"(10.16 cm)box,surface mount using the SMB500. MS-92000D:198-pointaddressable Fire Alarm Control Panel. BG-12LX: Addressable manual pull station with interface Includes 80-character LCD display,single printed circuit board, module mounted inside. and cabinet. 1300: This module isolates the SLC loop from short circuit ACM-8RF:Optional plug-in relay module provides 8 Form-C conditions(required for Style 7 operation). 5.0 amp relays. PK-CD: Contains PK-Plus programming software for SMB500: Used to mount all modules except the MMF-301 Windows®-based PC computer(cable not included). and M301. DP-9200UD: Dress panel for MS-9200OD. MMF-300-10:Ten-input monitor module. Mount one or two FC-TR:Trim Ring for semi-flush mounting. modules in a BB-2F cabinet(optional).Mount upto six modules on a CHS-6 chassis in a BB-6F. BB-55F: Battery box, required to house two PS-12250 batteries and one CHG-120F battery charger. For batteries MMF-302-6: Six-zone interface module. Mount one or two greater than 25 AH, consult factory for housing/mounting modules in a BB-2F cabinet(optional).Mount up to six modules arrangements. on a CHS-6 chassis in a BB-6F. BB-26:Battery backbox,holds up to two PS-12250 batteries. CMF-300-6:Six-circuit supervised control module.Mountone CHG-120F Remote battery charging system for lead-acid or two modules in a BB-2F cabinet(optional).Mount up to six batteries with a rating of 25 to 120 AH. CHG-120F or CHG- modules on a CHS-6 chassis in a BB-6F. 75 required for charging greater than 25 AH batteries. CRF-300-6:Six Form-C relay control module.Mount one or CHG-75:Battery charger for lead-acid batteries with a rating two modules in a BB-2F cabinet(optional). Mount up to six of 25 to 75 AH. CHG-120F or CHG-75 required for charging modules on a CHS-6 chassis in a BB-6F greater than 25 AH batteries. NOTES: 1) Compatible with legacy Fire•Lite 300 Series de- PS-12180: Battery, 12 volt, 18.0 AH, (two required). vices. Please consult factory for further information on all the PS-12250: Battery, 12 volt, 25 AH, (two required; requires 300 series devices: CP300, SD300, SD300T, M300, M301, M302, C304, and BG-I0LX. 2) "A"suffix should be included CHG-75). only when ordering ULC listed units(e.g.,SD350A,MMF-300A). PS-12550: Battery, 12 volt, 55 AH, (two required; requires 3)For more information on Compatible Addressable Devices CHG-75). for use with the MS-9200OD, see the following data sheets PRT/PK-CABLE:Cable printer/personal computer interface (document numbers): SD350ISD350T (DF-52149), CP350 cable. (DF-52158),MMF-300 Series/MDF-300(DF-52121),BG-12LX DF-52013 , MMF-300-10 (DF-52347), MMF-302-6 Windows®is a registered trademark of Microsoft Corporation_ ( ) (DF- 52356),CMF-300-6(DF-52365),and CRF-300-6(DF-52374). COMPATIBLE ADDRESSABLE DEVICES COMPATIBLE ANNUNCIATORS All feature a polling LED and rotary switches for addressing. EIA-485 interface: Built into the motherboard. CP350/CP355: Addressable low-profile ionization smoke detector. AFM-LED Zone Series:LED-type fire annunciators capable SD350/SD355:Addressable low-profile photoelectric smoke of providing up to 99 software zones of annunciation.Avail- able in increments of 16 or 32 with expandable(AFM-X Se- detector. ries) and non-expandable (AFM Series) configurations to SD350T/SD355T: Addressable low-profile photoelectric meet a variety of applications. smoke detector with thermal sensor. ACS/ACM Annunciator Series:Allows annunciation of loop H350/H355: Fast-response, low-profile heat detector. modules and detectors. H350RIH355R:Fast-response,low-profile heatdetectorwith LDM Graphic Series: Lamp Driver Module series for use rate-of-rise option with custom graphic annunciators. D350P: Photoelectric duct smoke detector. LCD-80F(Liquid Crystal Display)point annunciator:80- D350RP:Photoelectric duct smoke detector with relayoption. character,backlit LCD-type fire annunciators capable of dis- playing English-language text.Up to 32 LCD-80F annuncia- MMF-300:Add ressable Monitor Module for one zone of normally- tors may be connected to the EIA-485 terminal mode serial open dry-contact initiating devices.Mounts in standard 4.0"(10.16 interface on the MS-9200OD motherboard. cm)box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B(Class B)or Style NOTE: For more information on Compatible Annunciators for use with the MS-9200OO, see the following data sheets D(Class A)IDC. (document numbers)AFM/AFM-X Series(DF-51465), ACM- MDF-300: Dual Monitor Module. Same as MMF-300 except 8RF(DF-51555),ACS/ACM Series(DF-52378),LDM Series it provides two Style B(Class B)only IDCs. (DF-51384), LCD-B0F(DF-52185). MMF-301:Miniature version of MMF-300.Excludes LED and AGENCY LISTINGS AND APPROVALS Style D option. Connects with wire pigtails. May mount in device backbox. See the first page of this data sheet for listing agencies and MMF-302: Similar to MMF-300, but may monitor up to 20 file numbers. These listings and approvals apply to the ba conventional two-wire detectors.Requiresresettable24VDC sic MS9200UD control panel. In some cases, certain mod- power. Consult factory for compatible smoke detectors. ules may not be listed by certain approval agencies,or list- CMF-300:AddressableControlModuleforoneStyleY/Z(Class ing may be in process. Consult factory for latest listing sta- B/A)zone of supervised polarized Notification Appliances.Mounts tus. Page 4 of 4 — DF-52293-06/17/03 July 8,2004 DF-52301 •D-025 FCPS-24FS6 Fire•LITe® ALarmYls 24 Volt, 6 Amp Remote Power Supply www_firelite.com Section: Power Supplies/Accessories GENERAL , California State Fire iMarshal The FCPS-24FS6 is a compact, cost-effective, 6-amp re L =__ 7315-0075:206 mote power supply with battery charger. The FCPS-24FS6 APPROVED may be connected to any 12-or 24-volt Fire Alarm Control LISTED M EA Panel (FACP) or may stand alone. Primary applications 24 include Notification Appliance (bell) Circuit (NAC) expan- S24 219.02-E sion (to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B(Style Y)or Class A(Style A, with ZNAC-4 option module). Alternately,the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. • Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. • Operates as a sync follower or a sync generator(default). See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone mode]). • Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300)for alarm activation. • Four ClassB(StyleY)orfourClassA(StyleZ)(withZNAC- • AC trouble report selectable for immediate or 8 hour 4 Module) Notification Appliance Circuits. delay. • 6.0 A full load output(3.0 A maximum per circuit)in NAC - Works with virtually any UL 864 fire alarm control which expander mode (UL 864). utilizes an industry-standard reverse-polarity notifica- 4.0 A continuous output in stand-alone mode(UL 1481). tion circuit (including unfiltered and unregulated bell In stand-alone mode, output power circuits may be power). configured as resettable(reset line from FACP required) • Requires input trigger voltage of 9.0-32 VDC. or non-resettable or a mix of two and two. - Self-contained in compact, lockable cabinet (15" [38.1 • Fully regulated and filtered power output (optimal for cm]H x 14.5"[36.8 cm]W x 2.75"[7.0 cm]D). powering four-wire smoke detectors, annunciators and • Includes integral battery charger capable of charging up other system peripherals requiring regulated/filtered to 18 AH batteries. Cabinet capable of housing 7.0 AH power). batteries. Power-limiting technology meets UL power-limiting re- • Battery charger may be disabled via dip switch for appli- quirements. cations requiring larger batteries. Form-C normally-closed trouble relay. • Fixed, clamp-type terminal blocks accommodate up to Fully supervised power supply, battery and Notification 12 AWG (3.1 mm2)wire. Appliance Circuits. • Selectable earth fault detection. Fire Lite® Alarms is a Honeywell company. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENINEE{IIVC 61YIlWUNICf0�IIIC For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. QUALITY SYSTEMS Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. Dr-52301 07/08/04 . Page 1 of 2 STANDARDS and CODES Example 2 The FCPS-24FS6 complies with the following standards: Use the FCPS-24FS6 to expand auxiliary regulated 24 volt • NFPA 72 National Fire Alarm Code system power up to 4 amps. Both non-resettable and resettable power options are available. UL 864 Standard for Control Units for Fire Alarm Sys- tems (NAC expander mode). Resettable outputs are created by connecting the resettable • UL 1481 Power Supplies for Fire Alarm Systems output from the FACP to one or both of the FCPS-24FS6 inputs. (stand-atone mode) Example 3 SPECIFICATIONS Use addressable control modules to activate the FCPS- Primary(AC)Power 24FS6 versus the FACP Notification Appliance Circuits. This • FCPS-24FS6: 120 VAC 60 Hz, 3.2 A maximum typically allows for mounting the FCPS-24FS6 at greater Wire size: minimum 14 AWG(2.0 mm2)with 600V insu- distances* away from the FACP while expanding system Iation. architecture in various applications. Control Input Circuit In this example, an addressable control module is used to - Trigger Input Voltage: 9.0 to 32 VDC. activate the FCPS-24FS6 and an addressable monitor • Trigger Current: 2.0 mA(16-32 V). module is used to sense FCPS-24FS6 trouble conditions. (per input) 1.0 mA(9- 16 V). Local auxiliary power output from the FCPS-24FS6 pro- vides power to the addressable control module. Trouble Contact Rating • 5.0 A at 24 VDC - AuxiliaryPowerOutput Fire Lite's MS-9200, MS-9"20000, (198-point)or MS-9600 (636- point)addressable FACPs have the capability of locating control • Specific Application Power- 500 mA maximum. and monitor modules up to 10,000 feet(3048 m)away. Output Circuits • +24 VDC filtered, regulated. Sync Follower/Generator Note: In some installations, it 3 0 A maximum for any one circuit. is necessary to synchronize the flash timing of all 4.0 A maximum total continuous current for all outputs strobes in the system for ADA compliance. Strobes (Stand-alone mode). accomplish this by monitoring very short timing pulses 6.0 A maximum total short-term current for all outputs on the NAC power,which are created by a Fire Alarm (NAC Expander mode) Control Panel such as the Fire•Lite MS-9600 When Secondary Power(Battery)Charging Circuit installed at the end of a MS-9600 NAC wire run, this • Supports lead-acid batteries only, power supply can track (i.e. "follow")the strobe synchro- Float Charge Voltage 27.6VDC. nization timing pulses on the existing NAC wire run. This Maximum Charge Current: 1.5 A. maintains the overall system flash timing of the addi- Maximum Battery Capacity' 18 AH. tional strobes attached to this power supply. When this power supply is configured (via DIP switch ORDERING INFORMATION settings) as a "sync follower," this supply's NAC outputs FCPS-24FS6 Remote charger power supply (120 track the strobe synchronization pulses present at this VAC). Includes main printed circuit supply's sync input terminal. The pulses are originated board, transformers, red enclosure, and from an upstream FACP or other power supply. installation instructions. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input FCPS-2456RB Replacement mother board. terminal are not used. Rather, this power supply is the PN 90286 FCPS-24F Module Mounting Kit originator of the strobe synchronization pulses on this power supply's NAG outputs. In "sync:generator" mode, ZNAC-4 Class A (Style Z) NAC option module the sync type(System Sensor, Wheelock, or Gentex)is A77-716B 12/24 VDC end-of-line relay for selectable via DIP switch settings. monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt,7.0 AH(two required). APPLICATIONS Example I Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B(Style Y)outputs or 4 Class A (Style Z)outputs(using the ZNAC-4). In this example: the FACP notification appliance circuits will activate the FOPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FOPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 — DF-52301 07/08104 May 3,2001 DF-52149 150 F I re LITe Alarms SD350(A)/SD35OT(A) Addressable Photoelectric Detectors www.firelite.com Section: Addressable Devices GENERAL The SD350 and SD350T Addressable, low-profile plug-in Photoelectric Detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's MS-9200 and MS-9600 Addressable Fire Alarm Control Panels. The 9EFAE�PP5 SD350T adds thermal sensors that will alarm at a fixed tem- perature of 135°F. Since this detector is addressable,it will help emergency personnel quickly locate a tire during its early 7272 0075:194 stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (Part No. RA400Z). FEATURES SLC Loop • 2-wire loop connection. • Unit uses base for wiring. Addressing • Addressable by device. • Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) entry of address Architecture • Unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. SD350 • Sleek,low-profile design. Other System Features • Integral communications and built-in type identification. • Fully coated circuit boards and superior RF/transient pro- • Built-in tamper-resistant feature. tection. • Removable cover and insect-resistant screen for simple • 94-VO plastic flammability rating. field cleaning. • Low standby current. Operation Options • Withstands air velocities up to 1,500 feet-per-minute with- • Remote LED output connection(Part No. RA400Z). out triggering a false alarm. APPLICATIONS • Factory preset at 1.5°/nominal sensitivity for panel alarm threshhold level. Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability,especially where • Visible LED"blinks"when the unit is addressed(communi- smoldering fires are anticipated.Ionization detectors are of- cating with the fire panel)and latches on in alarm. ten better than photoelectric detectors at sensing fast,flam- Mechanicals ing fires. • Sealed against back pressure. CONSTRUCTION • Direct surface mounting or electrical box mounting- These detectors are constructed of LEXAN®in an off-white • Mounts to: single-gang box, 3.5" or 4" octagonal box, or color.The SD350(T)plug-in low-profile smoke detectors are 4"square electrical box(using a plaster ring-included), designed to commercial standards and offer an attractive ap- pearance. This document is not intended to be used for installation purposes. We try to keep our '�O �00� It product information up-to-date and accurate. We cannot cover all specific applica- ions or anticipate all requirements. All specifications are subject to change without notice For more information,contact Fire•Lite Alarms,One Fire-Life Place,Northford, ________________ Connecticut 06472 Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ENCIM91INC&MANUFAC111I1i Made in the U.S.A. Back:888 388-3299. DF-52149— Page 1 of 2 INSTALLATION , PRODUCT LINE INFORMATION The SD350(T) Plug-In Detectors use a detatchable mount- S0350(A) Addressable Photoelectric Detector(B350LP base included). A model has ULC listing. ing base to simplify installation, service and maintenance. ) ( ) Mount base on box which is at least 1.5 inches (3.81 cm) SD35OT(A) Same as above with thermal element deep. Suitable boxes include: (B350LP base included).(A)model has ULC listing. • 4" (10 16 cm)square box with plaster ring. RA400Z Remote LED.Mounts to a single-gang box. • 4"(10.16 cm)octagonal box. B350LP Plug-in detector base (included).Diameter: 6.1"(155mm).Mounting:4"(102mm)square • 3 5"(8.89 cm)octagonal box. box with or without plastic ring, 4" octagon • Single-gang box box,3 1/2"octagon box or single gang box. All mounting boxes have a minimum depth of NOTE:Because of the inherent supervision provided by the 1.5"(38 mm)- SLC loop, end-of-line resistors are not required. Wiring "T- B224RB Plug-in System Sensor relay detector base. taps"or branches are permitted for Style 4(Class B)wiring. Diameter:6.2"(157 mm). Mounting 4"(102 OPERATION mm)square box with or without plastic ring, 4" octagon box, 3 1/2" octagon box. All Each SD350(T) uses one of 99 possible addresses on the mounting boxes have a minimum depth of MS-9200 Signaling Line Circuit(SLC) or up to 318 (159 on 1.5'(38 mm). each loop)on the MS-9600 SLC.It responds to regular polls B501 BH Plug-in System Sensor sounder detector from the system and reports its type and status. base.Diameter:6.0"(153 mm). Mounting:4" The SD350(T) Addressable Photoelectric SensorTM unique (102 mm)square box with or without plastic unipolar chamber responds quickly and uniformly to a broad ring. Mounting box has a minimum depth of range of smoke conditions and can withstand wind gusts up 1.5"(38 mm). to 1,500 feet-per-minute without sending an alarm level sig- nal. Because of the unipolar chamber,the SD350(T) is ap- proximately two times more responsive than most photoelec- tric sensors.This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested(required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to an MS-9200 or MS- 9600 addressable fire alarm control panel- The results of the sensitivity test can be printed off the MS-9200 and MS- 9600 for record keeping. SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched"ON"). Air velocity: 1,500 ft/min. (7.6 m/sec.) maximum. Diameter:5.0 inches(12.7 cm),6.2 inches(155 mm)installed in B350LP Base. Height: 1.7 inches(43 mm) installed in B35OLP Base. Weight: 3.6 oz. (102 g). Operating Temperature Range:0°to 49°C (32°to 120°F) SD350. Operating Temperature Range:0°to 38° C (32"to 100°F) SD350T. Temperature:0° -49°C (32°- 120°F). Relative humidity: 10%-93%, non-condensing. Page 2 of 2 — DF-52149 June 25, 2001 DF-52167 E-700 H350/H350R FIre-LITe® ALarrrls Intelligent Addressable Thermal (Heat) Detectors for use with MS-9600 www.firelite.com Section: Addressable Devices GENERAL U��+ 11 ` ' 7270-0075:195 The H350 and H350R model thermal detectors are address- able ., �N sensors that use a state-of-the-art thermistor sensing "' 'p }P• 1 circuit for fast response.These sensors are designed to pro- vide open area protection and are intended for use with the Seav;c { MS-9600 fire alarm control panel. F M Both the H350 and H350R sensors provide fixed tempera- ture alarm detection at 135°F. The H350R sensor responds to rate-of-rise conditions of greater than 15°F/minute. Two LED's on each sensor light to provide a local, visible sensor indication-Remote LED annunciator capability is avail able as an optional accessory (Part No. RA400Z). #A FEATURES SLC Loop • Two-wire SLC loop connection. Addressing • Addressable by device. • Direct Decade 01-159(MS-9600)entry of address. H350 Architecture • Sleek,low-profile,stylish design. • State-of-the-art thermistor technology for fast repsonse. • Integral communications and built-in device-type identifica APPLICATIONS tion. • Built-in tamper resistant feature. Use thermal detectors for protection of property. • Built-in functional test switch activated by external magnet. CONSTRUCTION Operation • Factory preset at 135°F(58°C) These detectors are constructed of Bayblend®in an off-white • Rate-of-Rise model(H350R), 15°F(8.3°C)per minute. color. • 360°-field viewing angle of the visual alarm indicators(two The H350 and H350R plug-in intelligent thermal detectors bicolor LEDs). LEDs blink green in Normal condition and are designed to commercial standards and offer an attrac- turn on steady red in Alarm. tive appearance. • Visible LEDs"blink"every time the unit is addressed. INSTALLATION Mechanicals • Sealed against back pressure. The H350 and H350R plug-in intelligent thermal detectors • SEMS screws for wiring of the separate base. use a detachable base to simplify installation, service and • Designed for direct-surface or electrical-box mounting. maintenance. Installation instructions are shipped with each • Plugs into separate base for ease of installation and main- detector. tenance. Mount base(all base types)on box that is at least 1.5"(38.1 • Separate base allows interchange of photoelectric,ioniza- mm) deep. Suitable boxes include: tion and thermal sensors. 4"(101.6 mm)square box. Other System Features • Remote test feature from the panel. • 3 1/2"(88.9 mm)or 4"(101.6 mm)octagonal box. • Walk test with address display. • Single-gang box(except relay or isolator base). • Low standby current. • 94-5V plastic flammability rating. NOTE:Because of the inherent supervision provided by the Options SLC loop, end-of-line resistors are not required. Wiring "T- • Remote LED output connection to optional RA400Z remote taps"or branches are permitted for Style 4(Class"B")wiring LED annunciator. only. • Recessed(RMK400)or surface(SMK400)base mounting kits. Bayblend®is a registered trademark of Bayer Corporation. This document is not intended to be used for installation purposes. We try to keep our 1S0 9001 product information up-to-date and accurate We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information,contact Fire•Lite Alarms,One Fire-Lite Place,Northford, Connecticut 06472. Phone: (800)627-3473, Toil Free FAX: (877)699-4105, FAX ENOlF E INC 8 MAN9FIICIJRIN6 Made in the U.S.A. Back:888 388-3299. DF-52167 — Page 1 n.2 OPERATION Each H350 or H350R uses one of 159 possible addresses (MS-9600)on a control panel SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status. It it receives a test command from the panel (or a local magnet test),it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel .The H350 and H350R otter features and performance that represent the latest in ther- mal detector technology. SPECIFICATIONS Diameter: 6.1" (155 mm) installed in B35OLP. Height: 2.0" (51 mm). Weight: 5 oz. (150 gm). Installation temperature: -4°to 100° F (-20°to 38°C). Humidity range:10%to 93%relative humidity(non-condens- ing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B35OLP flanged base. Fixed Temperature setpoint: 135° F (57°C). Rate of Rise detection:Responds to greater than 15°F/min. PRODUCT LINE INFORMATION H350 Intelligent thermal sensor(B35OLP base in- cluded). H350R Same as above with Rate-of-Rise feature. RA400Z Remote LED. Mounts to a single-gang box. B35OLP Plug-in detector base(included).Dimensions: 6-1"(155 mm. Mounting:4"(102 mm)square box with or without plastic ring,4"octagon box, 3 1/2" octagon box or single gang box. All mounting boxes have a minimum depth of 1.5" (38 mm). M02-04-00 Test magnet. B224RB Plug-in System Sensor relay detector base. Diameter: 6.2"(157 mm). Mounting: 4" (102 mm)square box with or without plastic ring, 4"octagon box, 3 1/2"octagon box. All mounting boxes have a minimum depth of 1.5" (38 mm). B501BH Plug-in System Sensor sounder detector base. Diameter:6.0"(153 mm). Mounting: 4"(102 mm) square box with or without plastic ring. Mounting box has a minimum depth of 1.5"(38 mm). Page 2 of 2 — DF-52167 May 2,2001 DF-52176 E-600 D350P/D350RP Fl re-LITe®AL, arms Intelligent Addressable Photoelectronic Duct Smoke Detector www.firelite-com Section: Addressable Devices GENERAL The new D350P and D350RP addressable photoelectric duct �� F M smoke detectors are used exclusively with the Fire-Lite MS- a and MS-9600 addressable tire alarm control panels. 9200 Since these duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early 3240 0075:189 stages, potentially saving precious rescue time while also reducing property damage.The D350RP offers the same fea- tures as the D350P while adding a Form-C relay. rr An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct sys- tem is'thus distributed to the entire building. Smoke detec- tors for use in air duct systems sense the presence of smoke in the duct. The D350P and D350RP air duct smoke detectors are pho toelectric detectors,combining this detection technology with an efficient housing design that samples air passing through of a developing hazardous con- D350P the duct. al lowing detectionP 9 dition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector.With the D350RP,appropriate action can be taken to shut off fans and blowers and to change over air handling systems, etc. This can isolate toxic smoke and fire gases or prevent their distribution thoughout areas served by the duct system. control panel specifications for wiring requirements before Iwo LED's on each detector light to provide a local, visible wiring the detector loop.The D350P/D350RP detector is de- alarm indication. A remote alarm output is provided for use signed for ease of wiring; the housing provides a terminal with auxiliary devices.The D350P and D350RP have remote strip with clamping plates. test capability with the RTS451/RTS451KEY Remote Test Remote LED annunciator capability is available as an op- Station,as well as remote communication using the RA400Z alarm LED. tion Each duct smoke detector can only be wired to one re- mote accessory APPLICATIONS SPECIFICATIONS Duct smoke detectors have the following limitations: • NOT a substitute for open area smoke detectors. D350P • NOT a substitute for early warning detection Operating voltage range: 15 to 32 VDC• . NOT a replacement for a building's regular fire detection Standby current- 300 pA @ 24 VDC (one communication system. every 5 seconds with LED blink enabled). Operating temperature range:32°to 131°F(0°to 55°C). Call your Fire-Cite distributor for a copy of System Sensor's Humidity range: 10%to 93%(non condensing). application guide, Proper Use of Smoke Detectors in Duct Applications(A05-1004-00). Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 meters/min.). INSTALLATION Dimensions: 14.375" (365.125 mm)wide x 5.500"(13.970 Wiring: For signal wiring (the wiring between detectors or mm)high x 2.750"(69.850 mm)deep. from detectors to auxiliary devices), it is recommended that Options: RTS451, RTS451 KEY, RA400Z. Separate auxil- single conductor wire be no smaller than 18 AWG(0.75 mm°). iary power not required. The duct smoke detector terminals accomodate wire sizes up to 12AWG (3.25 mm°). Flexible conduit is recommended D350RP for the last foot(30.48 cm)of conduit: solid conduit connec- Operating voltage range: 15 to 32 VDC (comm. fine volt- lions may be used if desired age)and 24 VACNDC or 120/240 VAC auxiliary power(sepa- Smoke detectors and alarm system control panels have speci- rate source). NOTE: The D350RP requires a separate aux- fications for Signaling Line Circuit(SLC)wiring. Consult the iliary source. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information,contact Fire•Lite Alarms,One Fire-Lite Place,Northford, b dl Connecticut 06472 Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ENCINEE&INC&MANNACTURINC Back:888 388-3299. DF-52176— Page 1 of 2 Standby current: 300 pA @ 24 VDC (one communication PRODUCT LINE INFORMATION D350P Addressable duct detector housing with every 5 seconds With LED blink enabled) Auxiliary power current draw(@ 24 VDC):26 mA(standby), photolectric smoke detector. 87 mA (alarm) D350RP Addressable duct detector housing with Operating temperature range: 32°to 131°F(0°to 55°C). photolectricsmokedetectorand DPDT relay. Humidity range: 10%to 93%(non-condensing). ST-1.5 Metal sampling tupe,duct widths 1'to 2'(see table at left for metric lengths). Duct air velocity: 500 to 4,000 teet/min. (152.4 to 1219.2 ST-3 Metal sampling tupe,duct widths 2'to 4' meters/min.). ST-5 Metal sampling tupe,duct widths 4'to 8'. Dimensions: 14.375" (365.125 mm) wide x 5.500" (13.970 ST-10 Metal sampling tupe,duct widths 8'to 12'. mm)high x 2.750"(69.850 mm)deep. RA400Z Remote annunciator alarr LED. Options: RTS451, RTS451 KEY, RA400Z APA451. n RTS451 Remote test station. Mounts in single-gang Relay contact ratings:2 Form-C,DPDT. 10 A @ 250 VAC. box. Includes red alarm LED and magnet 10 A @ 30 VDC (resistive). Minimum switching current of test switch. 100 mA @ 5 VDC. RTS451KEY Key-activated remote test station. INLET TUBE SELECTION F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. Outside Duct Width Inlet Tube* P48-55-00 Replacement end cap for plastic sampling tube. Up to 2 feet(0.6096 m) ST-1.5 P48-21-00 Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. 2 to 4 feet(0.6096 to 1.2192 m) ST-3 A5067 Replacement power board(without relay). A5060 Replacement power board(with relay)- 4 to 8 feet(1.2192 to 2.4384 m) ST-5 8 to 12 feet(2.4384 to 3.6576 m) ST-10 *NOTE: Inlet tube is required and must be purchased separately.Order one inlet tube for each duct smoke detec- tor ordered. Page 2 of 2 -- DF-52176 July 14,2004 DF-52004 F-050 BG-12 Series FO re•LIT45 ALarms Manual Fire Alarm Pull Stations www.firelite.com Section: Conventional Initiating Devices GENERAL L:_ ;; California State Fire The Fire•Lite Alarms BG-12 Series is a cost-effective,tea- I'' i '\' Marshal Lure-packed, non-coded series of manual fire alarm pull `' f_: 7150-0075:184 stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series LISTED features a variety of models including single- and dual- action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels(FACPs), as well as other manufacturers' controls, 67-02-E with a manual alarm initiating input signal. Its innovative APPROVED design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated (single-or dual-action), yet designed to II prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. • The word"ACTIVATED"appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction. for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. • Terminal numbers are molded into the backplate, clime nating the need for labels. Station can be opened for inspection and maintenance • Switch contacts are normally open. without initiating an alarm. Product ID label viewable by simply opening the cover; Can be surface (with SB I10 or SB 10) or semi flush label is made of a durable long-life material. mounted. Semi-flush mount to a standard single-gang, ^ The words "NORMAL" and "ACTIVATED" are molded double-gang, or 4" (10 16 cm) square electrical box. into the plastic adjacent to the alarm switch (located in- • Backplate is large enough to overlap a single-gang side). backbox cutout by up to 112" (127 mm). Four-position terminal strip molded into hackplate. • Optional trim ring (BG-TR). Terminal strip includes Phillips combination-head cap- • Spanish version (FUEGO) available (BG-12LSP) tive 8/32 screws for easy connection to initiating Device Designed to replace the Fire•Lite Legacy BG-10 Series. Circuit (IDC). • Models packaged in attractive, clear plastic (PVC), Terminal screws backed-out at factory and shipped ready clamshell-style, Point-of-Purchase packages. Packag- to accept field wiring (up to 12 AWG/3.25 mmz)- ing includes a cutaway dust/paint cover in shape of pull station. Ere^ Ala msis is a Honeywell company. IS0 9 01 This document is not intended to be used for installation purposes.We try to keep «- ou- product information up-to-date and accurate- We cannot cover all specific applications or anticipate all requirements. All specifications arc subject to change without notice ENCINEERINCiMANBNICTUBING For more information, contact Fire•I_de Alarms. One Fire-Lite Place. Northford, QUALITY SYSTEMS Connecticut 06472. Phone: (8001 627-3473.. Toll-Free FAX: (877) 699-4105. DF-52004•07114/04 Page i of 2 CONSTRUCTION ties Act(ADA)or per national/local requirements- Manual • Cover, backplate and operation handle are all molded Stations shall be Underwriters Laboratories listed. at durable polycarbonate material. *NOTE: The words"FIRE/FUEGO"on the BG-12LSP shall ap- Cover features white lettering and trim pear on the front of the station in white letters.approximately 3/ Red color matches System Sensor's popular 4"high SpectrAlertTM horn/strobe series. PRODUCT LINE INFORMATION OPERATION Model Description The BG-12 manual pull stations provide a textured finger- BG-12S Single-action pull station with pigtail connec- hold area that includes Braille text. In addition to PUSH tions., hex lock. iN and PULL DOWN text,there are arrows indicating how BG-12SL Same as BG-12S with key lock. to operate the station, provided for non English-speaking persons BG-12 Dual-action pull station with SPST N/O Pushing in and then pulling down on the handle activates switch,screw terminal connections-hex lock. the normally-open alarm switch Once latched in the down BG-12L Same as BG-12 with key lock. position, the word "ACTIVATED" appears at the top in BG-12LSP Same as BG-12L with English/Spanish bright yellow, with a portion of the handle protruding at (FIRE/FUEGO) labeling. the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent). twist one quar- BG-12LOB Same as BG-12L Includes outdoor listed with backbox, and "outdoor seal- spring-loaded'then open the station's front cover, causing the spring-loaded operation handle to return to its original ing gasket. position. The alarm switch can then be reset to its normal BG-12LO Same as BG-12L with "outdoor use" listing. (non-alarm) position manually (by hand)or by closing the Does not include backbox. station's from cover,which automatically resets the switch. BG-12LA Same as BG-12L with auxiliary contacts. SPECIFICATIONS BG-12LPS Same as BG-12L with presignal feature. Physical Specifications-, BG-12LPSP Same as BG-12LPS with English/Spanish (FIRE/FUEGO) labeling. SB-I/O Indoor/outdoor backbox. 00®l0m®0 00-O0 00 10 00`0 Don SB-10 Indoor use backbox. WQU0 risc WCma mi ii: h.0[rilmn0 a,'',IOAC 00 0omur � - na.z uii 97on sc24W r U-/"W WP-10 Outdoor use backbox. mm= sc;;®unn 4.I-,1®0000 a.h �.�soanno WBB Outdoor use backbox. io.aroal u��ioai IoaIU5 �io.��Too� 17003 Keylock. o nom L ®m°5 ��'�®o rciu ,�,�'� ��1°°� s mmo 17007 Hex lock_ 1.390. E (33 06) Specifications. �� _ Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC- Wire Length ENGINEERS' & ARCHITECTS' Strip Gauge SPECIFICATIONS Manual Fire Alarm Stations shall be non-code,with a key or hex-operated reset lock in order that they may be tested, i 1 000" and so designed that after actual Emergency Operation, (25.40) ,hey cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it self so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXANCF) (or 0.750" polycarbonate equivalent)with clearly visible operating in (19.05) structions provided on the cover. The word FIRE shall ap 5.500" pear on the front of the stations in white letters, 1.00 inches (139.70) (254 mm) or larger.' Stations shall be suitable for sur- face mounting on matching backbox SB 10; or semi-flush (mm) mounting on a standard single-gang, double-gang, or 4" (10.15 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- Page 2 of 2 -- DE-52004 07/14/04 July 14, 2004 DF-52121 -E-325 E'• T �Alarms MMF-300(A) Series/MDF-300 F I r L� Addressable Monitor Modules www.firelite.coin Section: Addressable Devices GENERAL y: California �s.'kF- Four different monitor modules are available for Fire Lite / State Fire Ala ma MS 9200. MS 9200UD and MS 9600intelligent fire i` f)) Marshal alarm control panels to suit a variety of applications. Moni- ';F5. -1, 7300 0075:185 tor modules are used to supervise a circuit of dry-contact �� - input devices, such as conventional heat detectors and pull FM stations, or monitor and power a circuit of two-wire smoke ! APPROVED detectors (MMF-302). LISTED L MMF-300 (Replaces M300) —The MMF-300 Moni- tor Module is a standard-sized module(typically mounts to a CSXXXX 4" [101.6 mm]square box)that supervises either a Class A (Style D) or Class B(Style B) circuit of dry-contact input de- CFl-Mi;N vines MMF-301 (Replaces M301)—The MMF-30 i is a Min- iature Monitor Module (a mere 1 3" (33.02 mm) H x 2.75" (69.15 mm) V' x 0.5" (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to be mounted in a single-gang box behind the device it is monitoring. MMF-302 (Replaces M302) —The MMF-302 Inter- arc Module is a standard-sized module used to monitor and supervise compatible two-wire. 24 volt smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 (New)—The MDF-300 Dual Monitor Module is a standard-sized module (typically mounts to a 4" [101.6 m) square box)that supervises two Class B (Style B) cir- cuits of dry-contact input devices. MMF-300 MONITOR MODULE MDF-300 Built-!n type identification automatically identifies this de- vice as a monitor module to the control panel Device Circuit. A 47K ohm End-of-Line Resistor (provided) Powered directly by two-wire SLC loop. No additional terminates the Style B circuit. No resistor is required for power required supervision of the Style D circuit. Maximum IDC resistance • High noise (F_MF/RFI) immunity. is 1,500 ohms. SEMS screws with clamping plates for ease of wiring. MMF-300 Operation — Each MMF-300 uses one of Direct Decade 01 — 99 (MS-9200 and MS-9200OD) and 99 (MS-9200 and MS-9200OD) or 159 (MS-9600) avail- 01-159 (MS-9600) entry of address able module addresses on an SLC loop. It responds to LED flashes red during normal operation and latches regular polls from the control panel and reports its type on steady to indicate alarm and the status (open/normal/short) of its Initiating Device The MMF-300 Monitor Module is intended for use in Intel- Circuit (IDC). A flashing LED indicates that the module is Iigent, two-wire systems, where the individual address of in communication with the control panel. The LED latches each module is selected using the built-in rotary switches. steady on alarm (subject to current('imitations on the loop). it provides either a two-wire or four-wire Class A or Class MMF-300 Specifications B fault-tolerant Initiating Device Circuit (IDC) for normally- Nominal operating voltage: 15 to 32 VDC. open-contact fire alarm and supervisory devices The MMF- Maximum current draw: 5.1 mA (LED on). 300 can be used to replace M300 modules in existing sys- ferns Average operating current: 400 pA (LED flashing) MMF-300 Applications — Use to monitor a zone of EOL resistance: 47K ohms. four-wire smoke detectors manual fire alarm pull stations, Temperature range: 32"F to 120F (0'C to 49`C). waterflow devices or other normally-open dry contact alarm Humidity range: 10% to 93% noncondensing- activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- Dimensions: 4 5" (114.3 mm) high x 4" (101.6 mm)wide x lion at the control panel Monitored crrcuit may be wired as 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square an NFPA Style B (Class B) or Style D (Class D) Initiating x 2.125" (53.975 mm) deep box. Fire-Lite®cu Alarms is a Honeywell company- This document is not intended to be used for installation purposes_ We try to keep our product information up-to-date and accurate We cannot cover all specific applications or anticipate all requirements- All specifications are subject to change without notice. tN611iERINCtMIWUFCTURIIYC For more information. contact Fire-Lite Alarms. One Fire-Lite Place. Northford, Connecticut 06472. QUALITY SYSTEMS Phone. (800) 627-3473, Toll-Free FAX. (877) 699-4105. OF-52121 -07/14/04 — Page 1 of 3 MMF-301 MINI MONITOR MODULE ' MMF-302 INTERFACE MODULE Built-in type identification automatically identifies this Supports compatible two-wire smoke detectors. device as a monitor module to the MS-9200. MS- Supervises IDC wiring and connection of external power 9200UD or MS-9600. source (resettable). Powered directly by two-wire SLC Loop. No additional High noise (EMF/RFI) immunity. power required i SEMS screws with clamping plates for ease of wiring High noise (EMFlRFI) immunity. Direct-dial entry of address (01-99 for MS-92001MS- inned stripped leads for ease of wiring. 9200OD 01-159 for MS 9600). Direct-dial entry of address (01-99 for MS-9200/MS- LED flashes during normal operation_ 9200OD 01-159 for MS-9600). • LED latches steady to indicate alarm on command from The MMF-301 Mini Monitor Module can be installed in a control panel. single-gang junction directly behind the monitored unit. Its The MMF-302 Interface Module is intended for use in intel- small size and light weight allow it to be installed without , ligent, addressable systems, where the individual address rigid mounting. The MMF-301 is intended for use in intelli- I of each module is selected using built-in rotary switches. gent, two-wire systems where the individual address of This module allows intelligent panels to interface and moni- each module is selected using rotary switches. It provides for two-wire conventional smoke detectors. It transmits the a two-wire initiating device circuit for normally-open-con- status (normal, open, or alarm) of one fu'I zone of conven- tact fire alarm and security devices. The MMF-301 can be tional detectors back to the control panel. All two-wire de- used to replace M301 module in existing systems tectors being monitored must be UL compatible with the module. 1415 0 1 1. ADDRESS 1 I MMF-302 Applications—Use the MMF-302 to moni- 13 2 2 tor a zone of two wire smoke detectors_ the monitored ar- 12 LOOP 's cuit may be wired as an NFPA Style B (Class B) or Style D �� a 1 5 (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line 10 8 6 ,6 Resistor (provided) terminates the end of the Style B or D 7 TENS ONES (class B or A) circuit (maximum IDC loop resistance is 25 _ ohms). Install ELR across terminals 8 and 9 for Style D t 1'f application. IIMMF-302 Operation — Each MMF-302 uses one of 159 available module addresses on a MS-9600 SLC loop. It uses one o₹ 99 on a MS-9200 or MS 9200OD. It responds to regular polls from the control panel and reports its type and the status (openlnormal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302 Specifications Nominal operating voltage_ 15 to 32 VDC. MMF-301 Applications — Use to monitor a single Maximum current draw: 5.1 mA (LED on)_ device or a zone of four-wire smoke detectors, manual fire Average operating current: 270 pA (LED flashing). alarm pull stations,waterflow devices,or other normally-open EOL resistance: 3.9K ohms. dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- External supply voltage (between Terminals 73 and T4) lion at the control panel. Monitored circuit/device is wired DC voltage: 18 to 28 volts power limited_ Ripple voltage: as an NFPA Style B (Class B)Initiating Device Circuit.A 47K 0.1 VRMS maximum. Current:90 mA per module maximum. ohm End-of-Line Resistor (provided)terminates the circuit. Requires regulated, resettable 24 VDC power. MMF-301 Operation — Each MMF-301 uses one of Temperature range: 32°F to 120°F (0"C to 49°C) 159 available module addresses on an SLC loop MS- Humidity range: 10% to 93% noncondensing. 9600. It uses one of 99 on a MS-9200 or MS-9200OD. It responds to regular polls from the control panel and re- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm)wide x 1.25" (31 75 mm) deep_ Mounts to a 4" 101.6 mm) square ports its type and the status (open/normal/short) of its Ini x 2.125' (53.975 mm) deep box. hating Device Circuit (IDC). MMF-3O1 Specifications MDF-300 DUAL MONITOR MODULE Nominal operating voltage: 15 to 32 VDC - Built-in type identification automatically identifies this de- Average operating current: 375 pA maximum vice as two monitor modules to the control panel. EOL resistance: 47K ohms. Powered directly by the two-wire SLC loop. No addi- tional power required. Temperature range: 32°F to 120°F (0°C to 49"C). High noise (EMF/RFI) immunity. Humidity range: 10% to 93% noncondensing. - SEMS screws with clamping plates for ease of wiring. Dimensions: 1.3"(33.02 mm)high x 2.75"(69.85 mm)wide Direct-dial entry of address (01 — 159 on the MS-9600. x 0 5" (12.70 mm) deep_ 01-99 for MS-9200IMS-9200OD). Wire length: 6" (152.4 mml minimum. • LED flashes red during normal operation and latches on steady red to indicate alarm. Pogo 2 of 3 — DF-52121 -07114,04 The MDF-300 Dual Monitor Module is intended for use in ordinances and regulations. intelligent. two-wire systems. where the individual address ARCHITECTS'/ENGINEERS' of each module is selected using the built-in rotary switches- It provides two independent two-wire fault-toler- SPECIFICATIONS ant Initiating Device Circuits (IDCs) at two separate, con- Specifications of these and all Fire-I.ite Alarms products secutive addresses It is capable of monitoring normally are available from Fire-Lite Alarms. open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-tire ap- PRODUCT LINE INFORMATION piications. MMF-300 Monitor Module. MDF-3OO Applications - Use to monitor a zone of MMF-300(A) Monitor Module (Canada) four-wire smoke detectors, manual fire alarm pull sta- tions waterflow devices, or other normally-open dry-con- MMF-301 Mini Monitor Module. tactalarm activation devices. May also be used to monitor MMF-301(A) Mini Monitor Module (Canada). normally-open supervisory devices with special supervi- MMF-302 Two-Wire Detector Monitor Module sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device MMF-302(A) Two-Wire Detector Monitor Module (Canada). Circuit The 47K ohm End-of-Line Resistors (provided) MDF-300 Dual Monitor Module. terminate the Style B circuit. Maximum IDC resistance is SMB500 Optional Surface-Mount Backbox. 1.500 ohms. MDF-3OO Operation - Each MDF-300 uses two of 99 MOUNTING DIAGRAM (MS-9200 or MS-9200UD) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular for standard-sized modules polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in com- munication with the control panel. The LED latches steady -i on alarm (subject to current limitations on the loop). MDF-300 Specifications Nominal operating voltage: 15 to 32'2DC- Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). _ EOL resistance: 47K ohms. Maximum IDC wire resistance: 1.500 Ohms. ✓� Temperature range: 32°F to 120°F (0 C to 49°C). Humidity range: 10% to 93°/ noncondensing. Dimensions: 4-5" (114.3 mm) high x 4" (101.6 mm)wide x I 1.25' (31.75 mm)deep. Mounts to a 4'" (101,6 mm)square x 2 125" (53.975 mm) deep box j Accessories: SMB500 electrical box. INSTALLATION MMF-300, MMF-302 and MDF-300 modules mount di- rectly to a standard 4" (101 6 mm) square, 2.125" (53.975 mm) deep. electrical box They may also be mounted to ,he SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes. ordi- nances and regulations- These modules are intended for power-limiter wiring only. The MMF-301 module is intended to be wired and I mounted without rigid connections inside a standard elec- trical box All wiring must conform to applicable local codes ) / of-52121 -07/14/04 — Page 3 of 3 September 28,2001 DF 52130 [-350 CMF and CRF Series Flre-uTe� ALarms Addressable Control and Relay Modules www.firelite.com Section: Addressable Devices GENERAL CMF-300 Control Module (Replaces C304) T!" F M The CMF-300 Addressable Control Module provides qy Approved .R) Fire•Lite Alarm's MS-9200 and MS-9600 intelligent control � panels a supervised Class B (Style Y) or Class A (Style Z) AF > SERVICE circuit for Notification Appliances (horns, strobes, etc.). 7aoo-oo7s.1es Addressability allows the CMF to be activated, either manu- ally or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 configured as a relay) CONIf;OL The CRF-300 Addressable Relay Module provides the MS-9200 and MS-9600 systems with two isolated sets of Form-C dry-contact outputs for activating a variety of auxil- F � tary devices, such as tans, dampers, door holders, con- -i trol equipment. etc. Addressability allows the dry contact to be activated, either manually or through panel program- � 3--- ming, on a select basis. j . a FEATURES T. Built-in type identification automatically identities these . devices to the control panel. - internal circuitry and relay powered directly by two wire Sl-C loop. The CMF module requires power (tor horns, t � strobes.etc.). S_ • Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. CMF-300 and CRF 300 Module - Nigh noise immunity (EMF/RFI). - The CMF may he used to switch 24-volt NAC power. OPERATION • Wide viewing angle of LED. Each CMF or CRF uses one of 99 (MS-9200) or 159 (MS- SEMS screws with clamping plates for wiring ease. 9600) possible module addresses on a SLC loop. It re- • Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) sponds to regular polls from the control panel and reports entry of address its type and status, including the open/normal/short sta- API9LiCATIONS tus of its Notification Appliance Circuit (NAC). The LED blinks with each poll received On command, it activates The CMF is used to switch 24 VDC audible/visual power. its internal relay. The CMF supervises Class B (Style Y)or The CRF may be programmed to operate dry contacts for Class A (Style Z) notification or control circuits. door holders, Air Handling Unit shutdown. etc. Upon code command from the panel, the CMF will discon- CONSTRUCTION nect the supervision and connect the external power sup- ply in the proper polarity across the load device. The dis- The face plate is made of off-white Noryl®. connection of the supervision provides a positive indica- Controls include two rotary switches for direct-dial entry tion to the panel that the control relay actually turned ON. of address (01-99 on the MS-9200 and 01-159 on the The external power supply is always relay isolated from MS-9600). the communication loop so that a trouble condition on the The CMF is configured for a single Class B (Style Y) or external power supply will never interfere with the rest o₹ Class A (Style Z) Notification Appliance Circuit the system. The CRF provides two Form-C dry contacts that switch Rotary switches set a unique address for each module together. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module Noryi®is a registered trademark of GE Plastics. a subsidiary of to the control panel, so as to differentiate between a mod- General Electric Company. ule and a sensor address. i h document is not intended to be used for installation purposes. We try to keep '�O �Q01 0,11 product information up-lo-date and accurate. We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice- For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Norihloid, Connecticut 06472. Phone. (800) 621 3473, Toll Free FAX: (877) 699- ENMIFIERING&MANUFACTRRIAR Made in the U.S.A. 4105, FAX Back:(888) 388-3299. DF-52130— Page 1 of 2 SPECIFICATIONS FOR CMF RELAY CONTACT RATINGS Normal operating voltage: 15 to 32 VDC. for both CMF and CRF models Maximum current draw: 5.1 mA (LED on). Load Description Application Maximum Current Average operating current: 390 pA (LED flashing). Voltage Rating External supply voltage (between Terminals 13 and T4): Resistive Non-Coded 30 VDC 3.0 A maximum 80 volts (RMS or DC). Resistive Coded 30 VDC 2.0 A Drain on external supply: 2 mA maximum (using internal Resistive Non-Coded 110 VDC 0.9 A EOL relay). Resistive Non-Coded 125 VAC 0.9 A EOL resistance: 47K ohms. Inductive(UR=5 ms) Coded 30 VDC 0.5 A Temperature range: 32"F to 120'F (0°C to 49°C). Inductive(L/R=2 ms) Coded 30 VDC 1.0 A Humidity range: 10%to 93% non-condensing. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A Dimensions: 4.5" (114.3 mm ) high x 4" (101.6 rnm)wide x 1.25" (31 75 mm)deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 µA (LED flashing). EOL resistance: not used. Temperature range: 32"F to 120"F (0"C to 49"C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25"(31-75 mm)deep. Mounts to a 4"(101-6 mm)square x 2 125" (53.975 mm)deep box. PRODUCT LINE INFORMATION CMF-300 Intelligent Addressable Control Module. - CRF-300 Intelligent Addressable Relay Module. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier — required by UL for separating power-limited and non power lim- ited wiring in the same junction box as CMF-300. j' f1 MOUNTING I DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant I CB500---i p1 I} rig II - llIj >, ISOLATED QUADRANT mc n- - 4"(101 6 mm)square x 2.125"(53.975 mm)deep box Page 2 of 2 DF-52130 as • e 1 1 / 1 1 . 5 * Models Available SC241575W PC2475W- � 5W C S 4 SC2415 � 2 1 SC241575W $C241575 ,� C�" SC243OW SC2430 SC2475W' SC2475 } 7t SC2495 { SC24115W SC24115 772 77' SC24177 PC2415W PC2415 c � PC241575W PC241575 �_• r � PC2430W PC2430 PC2475W P72475 s�r PC2495'vV PC2495 �' aW 0724115W PC24115 �bv PC24177W PC24177 BBSCW BBSC Product Overview — -- Like the original Specti,Alert, the SpectrAlert ceilint; mount series rifler siinificaut current draw reductions over other ceiling mount strobes and ho;n/siroks SpectrAlert's compact design also offers Installation sayings. The strobe ,and horn/strobe models mount to a 4'x4'x I;" back box, arid take up little room in the hack box, making connections easier. And with Spectr Alert's r�.mud shape it is not necessary to align the hack bow with the room's walls. Spectr Ale;t always lines up. SpectrAlert ceiling mount strobes and horn/strobes arc available in seven different candelas, including 177 candela for sleeping; areas. The horn/ strobe's otics are field-selectable through the use of a three position switch located on the back of the unit- Selections include electromechanical and 3 K11/ tones, temporal and non-temporal patterns, and high and low volume- SpectrAlcrt ceiling strobes and horn/strobes offer a design that is scnsi- tisc to the aesthetic demands of ceiling mount applications.The round shape main- .,J �p twins a iuw profile appearance, similar to that of a smoke detector and provides �� Fm Ar1E� clearly visible "I'TRV," identification from all angles- approved j. ^COFSi fiLnO 1. qa m: za>>u�,ze�. Engineering Specifications gttbe shall he a System Sensor SpectrAlert \lodcl listed to Ul. 1971 and he approved for fire protective ser- icc •Here ceiling momit strobes are permitted the strobe shall he wired as a prtniary signaling a �eitotemation(lish tube and hance ad shall flash at II lx over the strobes entire riperaun range. The strobe light shall consist o associated lens/reflector sVStem. I loin/strobe shall he a Ssstetn Sensor SpectrAlert Model _ listed to UL 1971 and UI, 464 and he approved fit, hrc hrvrct, c service whet ceiling mount horn/strobes are permitted- '1 he horn/strobe shall he wired as :a ptimar� si<�n�ilin, notihcation appliance and shall flash at 1T it reel tts entire operating tame_ the strobe light shall consist of a on flash tube and associated lens/reflector s stem. 1 he hors shall have two mine options, two audibility opaons, and the option to switch burs cen a temporal and a non-temporal continuous pattern. these options shall be selected by a multi m siiton switch. Strobes shall he powered independently of the sounder with the removal of factory installed jump eye il—e . I e horn on horn/strobe models shall operatc on a coded or non-coded power supply. Note- the strobes must he powered continuously for the horn to operate_ General Specifications — — 5 diameter 32° to 120° F (0°to 49°C) 5.3 oz. (150 grams) x /t 1'/" back box or 4'x 4 2,/.- back box (with skirt) SpectrAlert Mounting Diagrams 4x4x2'/'" U1 d BBSCW Strobe or Horn/Strobe with mounting Plate Strobe or Horn/Strobe with Accessory Back Box Skirt Electrical Specifications 24 VDC and FWR' uniiltered 16-33 V 6.049,446 — — 6,057.778 D424,465 5. 2 to 18AWG 17 33 V 5 u `Navr ;t FWRj voltage ;s a non-regulated, rnre puw(<r source that is used on some power supply and panel outputs- ?. I e,n1l)t cou'es a a it '�oit voltage drop in the n;t'icat;nn appliance circuit. Table 1-A:SpectrAlert Strobe UL Max. Current Draw (mA RMS) Table 1-B: Horn UL Max.Current Draw Measurements(mA RMS) .. Low [lectromerhanical - — -13 — L_ Volumrt3000 3000 H,Inlet upini 33 75 15 68f4 - — — High LIcctrome hanira1 I 53 44 13/79 77 78 I Volumr Ht Interrupted I / 4 113 30 j 90l owfEl(,,(;lromechanical ;7 29 197 205 Volu00 H7 Interrupted 32 91 239 274 Hi hectromechanicalVolu298 325 � 000 H7 Internipted 56 l _ S 1 7 7 399 489 — Table 1-C: 24V DC Horn/Strobe UL Max. Current Draw Measurements(mA RMS) 1, 73 73 76 73 75 75 81 6 1 I 126 125 123 25 j i25 13 2 ≥25 222 22? j222 _—----219 — — — ---� 219 227 ... -__. 222 2 _.__... 'err---�- /, — /1- ! _266 265 269 21 97 2ra7 296 I 296 291 290 292 3 1r; 512 504 D01 496 ] 491 [493 491 496 Explanation of Published Voltage, Current, and SPL Specifications In Mae 2004 Underwriters Laboratories changed standard During May 20011, UL also changed the way they list the UT, 1971 to require that operating current measu rem tuents voltage range of a device- All 12V products well he listed it'" made usin;; EMS (root mean square] instead of peak between 8 - 17.5V and all 24V products will be listed ,5 2vera≤;e values_ RM`, measurements more accurately between 16 - 33V Those devices are consideieri 'ieguli- rlredict the power consumption of a device since they take ed". Any product that fines not operate within these ranges into account the entire current draw profile including surge, will be listed as a ""special application" with its open)tinl repel ills surge. and peak values. The published EMS cur voltage specified on the device- rent is the maximtun operating current of that device within In operating voltage range. phis current maximum may or Notes may trot occur at the endpoints of the voltage range. 1. Current draw for strobe-only products is shown in Table 1-A_ 1 2. 24VDC 2 wire horn/strobe current draw is shown in Table i,u arty, Ut, tests rile audibilit} of devices in accordance with Lie 484 by measuring them across the operating volt- 1c. age° range to determine the minimum sound pressure level 3- Current draw for other horn/strobe power supplies can be ducec at any r tiCttlar setting calculated by adding the strobe current in Table 1 A to the pro pat" I horn current in Table 1 B from the chosen settings Horn Sound Measurements (dBA) SpectrAlert Dimensions __ 2.2- Lnw v��lamx' Elec Irons ehansr it j _ 3001 Hz s tixruptr_d ' Hi- Jolulru; 11^ctromcrhanu il_ — Y.0 -- ._ . 3r(J JO Hx nterrupted � HI �/ I, 1 I�w alume I \ 1 .3000 Hx lcrniptrr', 7`) Hips Jolun;e Elec nom°chanw,Iil ---- H000 Hz Intern m ed SpectrAlert Ceiling Mount Strobe ;2 - SpectrAlert Ceiling Mount Horn/Strobe ordering Information PC241575W Ceiling mount horn/strobe. 24 volt. 15,a r5 candela. _ -- while SC2,1 1`x Ceiling mmint strobe 4 volt. 15 candela, red — — ---- PC2430 Ceiling mount horn/strobe, 2.4 volt, 30 candela ed— SC241*ti Costing Fount strobe. 24 volt. 15 candela.white PC2430W Ceiling mount horn/strobe, 24 volt. 30 candela. white — --- SC2a15x Ceiling mount strobo 24 volt, 15/x candela ter. — - --- PC2475 I Ceiling mount horn/strobe, 24 volt, 75 candela red 502 425 _"' Ceiling mount Stroh^. 24 volt. 15/15 candela white — — -- — PC2475W Ceiling mount horn/strobe, 24 volt, candela. white SC24;0 Ceiling-mount strobe. 24 vole, 30 candela, red C2495 Ceiling-mount horn/strobe,24 volt 95 c andela. Ted SC74oC4N 1 Ceilinr ouril erobe. 24 volt, 30 candela while a — _— PC249SW Ceiling mount horn/strobe.24 volt. 95 candela. white 5(:74 S Ceiling mount strobe. 24 volt. 75 candela.dela, re. — PC24115 Ceiling mount horn/strobe, 24 volt. 715 candela, red 5o2?r5W Ceiling-mount strobe. 24 volt. 75 candela white — PC24115W Ceiling mount horn/strobe. 24 volt, 115 r andela, 0C2495 C'fling mount stiohc. 29 volt, 95 .andela red whsle — — --557495W Ce/Lng mount strobe, 24 volt. 95 candela white 0024177 Ceiling-mount horn/strobe. 24 volt, 177 candela. red 5574315 Ceiling mount strobe. 24 volt. 1^5 candela. red PC24177W Ceiling mount horn/strobe. 24 volt, 177 candela. — — while Sr 115 1 elling mount strobe. 21 volt 115 candela white _ — -- -- - S57417/ , Ceiling mount st obe. 24 volt "l7r c andela T<d _ -- M d le red --- - — MDL Sync•Circui['"' M0 de SG24;77111 Cellint rt ount strobe, 24 volt, 17/ candela while — — — - -- MDLW Sync-Circuit'"' Module,white PC2n15 Getting mount ho n/Strobe.24 volt 15 candela. red — — p5/4 nBBSC Surface mount back box ski I- red 1-N Ceiling mount hom strobe 24 volt, 5 car white _ + " — — - 13BSCW Surface-mount back box skirt. white ('274157', Ceiling-mount horn/d-obe-24 volt 15/75 c indcio,red System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor-Far East System Sensor-India nh:86 29.8'3,7.01.19 Ph' 8',-22 191.9003 Ph:91.12!1 231 1770 p.2''ii) u25 Ohio r1�c'rut Ph_9U5 5121)7 r 17 �c Fx:8522-736.6580 Fx-91.124.2'l(.3118 St ( h rtes_ L 6 Yi.'4 rx:905.8120771 Fx.SiS 229 8832 5119 Pr /ctrl SE S'JR' System Sensor Europe System Sensor in Singapore System Sensor-Australia System Sensor-Russia 37'1,4 orr-44 140 11500 "Ii:65 6273 2230 Ph.513.54-781_-142 Ph: 7095-d37.7982 nrIMP Fx:613-54.281.112 Fe'70.95.937-7983 Fx. �l r,_14U�.2 x6501 Fx:65 617?_7610 nor,lo?r oosi•Dor,-vlssn ()^.7 S,[r. 5 r,,fir Tie L 1 any E 4_. 'r.,cc rhi i, f.iii,', ',,i,(m,rci Frhr;ii lone wit ho Ul[rotic, e r r SPECTM. P4 4k S i Models Available P1224MC Horn/Strobe Red White sit S1224MC S1224MCW S1224MCP S1224MCPW 51224MCK 51224MC5P �s Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK . � �I i s P1224MCSP '"" + Red White H12/24 H12/24W 4y (C s °Ue H12/24K s ,. Product Overview — - — r r rr <;, E,$ ... SpecrrAlert selectable output wall-mount horns,strobes,and horn/strobes offer key performance features long associated with the SpecrrAlert name The select able candela strobes and horn/strobes offer average current draws that are not oniv lower than conventional fixed-candela SpcctrAlcrr products, hilt also lower than similar selectable candela products. By consuming less current, the ability to connect even more device,per loop is possible,resulting in a lower installed cost. SpectrAlert selectable output horns,strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpcctrAlcrr name,such as the option of 2-and 4 wire operation;the ability to use standard site back boxes with no encroachment into the box;and universal mounting incorporating the lahor-saving All strobe and horn/strobe models incorporate a QuickC;lick"' feantce. Such labor-savings features make wire connections simple and fast, new patent pending voltage booster design that has a more consistent flash bulb voltage over further reducing installed cost. SpcctrAlcrr selectable output strobes and horn strobes offer the broadest the range of candela selections. The benefit to the customer is a high quality strobe device. range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either I 2V or 24V,with no setting required;the device rcroginifes mud self adjusts to the correct current automatically.Temporal 3 or<:onttnuous tone upturns ontmne to be available, in either an Fleetromechanical or 3kH'r.pattern_ LISTED rr ,NK, SpecrrAlert selectable output horns,strobes and horn/strobes incorporate du same stylish, lose profile design of the conventional SpecrrAlert products, foi awn MEAsistent and aesthetically pleasing appearance across the entire product line. approved „p .00awF� .'"4J., 14141 S 4 1)602-F Engineering Specifications — —— — —— — — -- — - fire protective service-Horn/strobe shall he wired as a primary ShectrAlcrt horns,strobes and horn/strobes shall he capable of signaling notification appliance and comply with the Americans ononong to a standard 4" x 4" x 1'/z" hack box or a single gang with Disabilities Act requirements for visible signaling Appliances, x 4 x 'I '• ha._k box 115104 the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage tange- includcd with each SpectrAlcr t product Also, SpcctrAlert prod The strobe light shall consist of a xenon flash tube and associated nets, when used in conjunction with the accessory Sync-Circuit lens/reflector system- The horn shall have,two tone options, two Modtdc, shall he powered born a non-coded power supply audibility options (at 24 volts) and the option to switch between and shahl operate on 12 or 24 volts 1 2 volt rated devices shall a temporal 3 pattern and a non-temporal continuous pattern. have an operatm4 voltage range of 9-17-S volts_ 24-volt rated Strobes shall be powered independently of the sounder with the desires shall lAave an operating voltage range or 17 33 volts- removal of factory installed jumper wires.the horn on horn! SpretrAlcrt products shall have an onerating temperature of strobe models shall operate on a coded or non coded power sup- 32" to 12(1°T and operate from a regulated D(. or full wave ply (the strobe must be powered coutuAuously)- rectitied, unfiltered power supply. Module shall he a System Sensor Sync (,ircuit—listed Strobe shall be a Sestctn Sensor SpcctrAlert Model — to U1,464 and shall he approved for fire protective service-The listed to 01. 1971 and be approved for fire protective service.The module shall synchronize SpcctrAlert strobes at 1Hz and horns sirohc shall be wired as:h primary signaling notification appliance at temporal 3. Also, the module shall silence the horns on horn/ and comply with the Americans with Disabilities Act require- strobe models, while operating the strobes, over a single pair of meats for visible signaling appliances,flashing at f IH,over the wires. f he module shall be capable of mounting to a 411/ ,, strobes court operating voltage range-The strobe light shall con- 4"/its" x 2'/x" back box and shall control two Style Y (class K) or of a xenon flash tube and associated lens/reflector system_ one Style Z(class A) circr it. Module.shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The tnodule Horn/Strobe shall he a System Sensor SpcctrAlert Model shall not operate on a coded power supply. listed to tfl,197 1 and LJI.464 and shall be approved for Specifications -- — — — — — SpecirAk:,rt horn/strobe and horn only 8.8 oz. 12v: 8—?7.5v; 2nv: 16-33v work on "walk tests" with time Jura Lions of 4 seconds or greater 4„ x 4" x 1l/-" or 2" x 4" x 1 /8" standard 12V: 9-175V; 24V: 17-33V — - standard boxes 121n 18 AWG *Note for Strobes: Do not exceed: 1) — — 16-33 or 8-17.5 voltage range limit: 32°F to 120°F (0°C to 49°C) 2) maximum number of 70 strobe lights Strobe and horn/strobe with universal — — when connecting the MDL Sync module plate 95% as tested per UL464 with a maximum line impedance of 4 `>" x 5�'/X" x 2'`'/n,' — — — — ohms per loop ard; 3) maximum line Strobe and horn/strobe with small impedance as required by the fire alarm Weatherproof(horn and horn/strobes) control manufacturer footprint plate 3j E s/ri x 25/is" 32°F to 150°F (0°C to 66°C) — /,,," x (outdoor strobe only) 5' n with universal mounting plate 40°F to 158°F (_40°C to 70°C) 5,593,569 5" x 55/7" x 1 /i " 5,914,665 ULC Canadian Models 6,049,446 Horn without mounting plate —40°C to 66°C 7. 12 or 24VDC and FWR unfiltered 2 oz. SpectrAlert Current Draw ------- ---— e v,G 112 64 127 59 S1224MC Strobes g x/75 135 74 127 .3 —_ __— --- 110 20 209 5 1 127 59 45-t 57.5 44. 74 57 01274M0 lb 112 6� - - 45 51.5 44-4 5 7 r 5 Horn/Strobes 1575 I 135 74 12 69 — 57 l5 --- 7 5 7.5 75 208 57 �5 — — . — 209 51.5 57 I — — —— 45.7 57-5 44.4 57 5 1-1112/24 Horns SpectrAlert Mounting and Operation — —Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the - - o -.0 Low Volume Electromechanical rear oi the product while watching the viewing window on the — _ 3000 Hz Interrupted Side of the reflector. High Volurne Flectromechanical —Permissible Candela Settings 3000 Hz Interrupted _ t Low Volume L1 Iectromechanical 3000 1Iz Interrupted 16 OK UK High Volume Flectromechanical 15/750R OK 3000 Hz Interrupted 75 OK DIP Switch Operation -- -- Factory DIP Switch 10 OK OFF ON Default Viewing Window _ AOI31 03 Low �TO High Temporal I�.d Non-Temporal n° IIL Electromech. 1 IL� 3000Hz ° ° Base(rear; anvu oa Typical weatherproof mounting with universal plate Plate #8-36 x 112"Flat Head r WBB Screw(4 total) C9 ®F- O l Gasket Conduit Entrance Slol `—Paper t finer Locking Rib For Plate Gasket SpectrAlert Ordering Information l — -- -- 111 ,_24 Horn92/24 volt. r ed ---�---- 01 224M LSeleciable Output Horn/Strobe 12/24 volt. red_ / _ H12/24W Horn. 12/24 volt, white P1224MCVv Selectable Output Horn/Strobe, 12124 volt.white ---- 1112/248 Horn, 12/24 volt, red, weatherproof '1224MCP Selct table Output Horn/Strobe., 12/24 volt.red, -- plain housing — — P1224MCPW Selecthle Output Horn/Strobe, 12/24 volt. MDL Sync•Circuit Module, red white, plain housing — -- — -- — - MDLW Sync.Circuit Module,white P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, --__ —MDLA Sync•Circuit Module, red, Canadian model jwcatherproof P1224MCSP Selectable Output Horn/Stroke, 12/24 volt, red, MDLWA Sync•Circuit Module,white, Canadian model "FUEGO" housing — S MP Small Footprint Mounting Plate. red, for single- - gang back box SI224MC Selectable Output Strobe, 12/24 volt, red — -- -- - - Small Footprint Mounting Plate, white, for stn e S1224MCW lover table Output Strobe. 12/24 volt, white S-MPW B S an back box 51224MCP Selectahle, Output Strobe. 12/24 volt, red. plain — — Surface Mount Lack Box Skirt. red Jhousing S1224MCPW Selectable Output Strobe, 12/24 volt,white, BBSW - Surface Mount Back Box Skirt,white plain hous!np; p_MO Universal Mounting Plate ( epfacernent). red — -- S1224MCK Selectable Output Strobe, 12/24 volt. red, D-MPW Universal Mounting Plate (replacement), white Iweatherproof_ — _ ---- — — — WBB Weatherproof Back Box SI224MCSP Selectable Output Strobe, 12/24 volt, red. "FUEGO housing Notes cn 1 Storm -Indoor mndcls U1,,U (,I'M.CSPM,Ml S.Wcathcrprouf models UL,(,SFM (strobe only), MF.A 1')C. all of these 5prctr,4lrn produeis are desigucd for wall mount only.All weatherproof inodcls must use weatherproof back bos model Wlie.1nsi,ill air on nl Its(hail iS candela srrolres niay be pernnssihlc under the egaivalriit faciliuuirnt Clause of the AI)AA( (Sec. 2.2).However,it is the responsibility uI Ili' person or cotta"designing the fire alarm systeni to dctcrruine the icccptability of less than 75 candela strobes. All I 5/75 candela strobes ur hunt/ 't robes,ire iccornmendcd for 20' x 20'rooms or less. SystemSensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor-Far East System Sensor-India Ph:86.29.574.625; Ph' 85 72.191 Ph:91..124237.1770 x.2100 825 Oh o venue Ph:905-8120767c Fx:85-22.736.6`[80 Fx: 91.124-7:2,7-3118 St.Cnadr.",h 601-4 x: 905 8120777 x:86.29574-ti25) ,,_ ur,n,;SF NSOP2 System Sensor Europe System Sensor in Singapore System Sensor-Australia System Sensor-Russia 630/377.6495Ph: 65.£,77327";0 Ph'. 013.54.281.142 iii 70.95.937.7987 G Ph_44.1401 .891920Fx. 70-95.937.7983 17neum^.sits-nn pernard Ix 44.140..7-891921 by:656273 7010 1, 613-54-281.172 300/731 7877 ww W.SV St('tri SFn50 r.1 ill Abe"i2 -00 5!09°#t700 �)7^04 Sc 1O1 tensor Lhrr company reserves the right to cha^ge product spa Iiicauone wrth vii'Duel' rFIre LIT e°ALarms MS-9200OD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Regulated Load in Standby • Main Circuit Board 1 x 0.255000 = 0.255000 ACM-8RF 0 x 0.030000 = ACM-16ATF 0 x 0.040000 = ACM-32AF 0 x 0.040000 = AEM-16ATF 0 x 0.002000 = AEM-32AF 0 x 0.002000 = AFM-16ATF 0 x 0.040000 = AFM-32AF 0 x 0.040000 = AFM-16AF 0 x 0.025000 = UDACT-F 0 x 0.040000 = LDM-32F 0 x 0.040000 = LDM-E32F 0 x 0.002000 = LCD-80F 1 x 0.025000 = 0.025000 4XTMF 0 x 0.005000 = 4-Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.025000 = Addressable Devices BEAM355 and BEAM355S 0 x 0.002000 = BEAM 1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 7 x 0.000300 = 0.002100 SD355T 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = D350P 6 x 0.000300 = 0.001800 D350RP 0 x 0.000300 = MMF-300 2 x 0.000400 = 0.000800 MMF-300-10 0 x 0.003500 = MDF-300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 4 x 0.000230 = 0.000920 CMF-300 0 x 0.000390 = CMF-300-6 0 x 0.002250 = CRF-300 0 x 0.000270 = CRF-300-6 0 x 0.001450 = 1300 0 x 0.000400 = B501 BH & B501 BHT(see note 3) 0 x 0.001000 = B224RB Relay Base 0 x 0.000500 = B224B1 Isolator Base 0 x 0.000450 = Current Draw from TB3(nonalarm) 0.000000 Total Standby Load 0.285620 Page 1 of 4 Notes: 1) Refer to the Device Compatibility Document for standby current 2) Must use compatible listed Power Supervision Relay 3) Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. 4) Current limitations of TB3 and TB4 circuits is 2.5 amps per NAC output and 0.5 amps per aux. power output 5) Total current draw listed cannot exceed 6.0 amps Page 2 of 4 ®Flre-LITeALarrns MS-9200OD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Regulated Load in ALARM Main Circuit Board 1 x 0.325000 = 0.325000 ACM-8RF 0 x 0.158000 = ACM-16ATF 0 x 0.056000 = ACM-32AF 0 x 0.056000 = AEM-16ATF 0 x 0.018000 = AEM-32AF 0 x 0.018000 = AFM-16ATF 0 x 0.056000 = AFM-32AF 0 x 0.056000 = AFM-16AF 0 x 0.065000 = UDACT-F 0 x 0.075000 = LDM-32F 0 x 0.056000 = LDM-E32F 0 x 0.018000 = LCD-80F 1 x 0.064000 = 0.064000 4XTMF 0 x 0.011000 = 4-Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.000000 = ALL Addressable Devices-Maximum draw 1 x 0.400000 = 0.400000 NAC#1 9 x 0.158000 = 1.422000 NAC#2 4 x 0.158000 = 0.632000 NAC#3 1 x 0.208000 = 0.208000 NAC#4 0 x 0.000000 = Current Draw from TB3(nonalarm) 0.000000 = Total Alarm Load 3.051000 Notes: 1) Current limitations for NAC circuits TB3 & TB 4 is 2.5 amps per circuit 2)ACM 8RF current based on a single module 3)Annuciator current based on all LED's lit 4) LDM-32F current with all LED's on 5) MMF 302 current limited to 90mA in alarm 6) Total alarm current cannot exceed 6.0 amps Page 3 of 4 F,re-ure A1arrYis MS-92OOUD Battery Calculation Note 1 You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Calculation in Total Sheet Use the total standby and alarm load currents calculated in tables A-2A and A-2B for the following battery calculations (24 01 60 Hrs.) Standby Load Current(Amps) 0.285620 x 24 = 6.855 AH (5 minutes = 0.084) Alarm Load Current(Amps) 3.051000 I x 0.084 = 0.256 AH Total Current Load 7.111 AH Multiply by the Derating Factorl 1.2 I = x 1.20 Total Ampere Hours Required 8.533 AH The MS 9200UD can charge this size battery The batteries can be stored in the cabinet iiitiIi1'rWl'4T NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS 9200UD without XRM-24 transformer **THE XRM-24 IS NEEDED TO SUPPLY THE REQUIRED OUTPUT CURRENT MS 9200UD with XRM-24 transformer The required output current is within the panel's limitations Page 4 of 4