Loading...
HomeMy WebLinkAbout08-8648 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8648 FIRE SPRINKLER SYSTEM PERMIT Permit Number: 8648 Address:433020TH ST Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: LIGHT INDUSTRY Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 13-26-21-0070-08900-0020 Improv. Cost: 5,000.00 Date Issued: 12/18/2008 Name: NESTLE WATERS NA, INC Total Fees: 210.00 Address: 4330 20TH ST Amount Paid: 210.00 ZEPHYRHILLS, FL. 33542 Date Paid: 12/18/2008 Phone: (813)783-1959 Work Desc: INSTALLATION ALTERATIONS TO SPRINKLER SYSTEM IN MEZZANINE & STORAGE AF BENEFICIAL FIRE PROTECTION,INC. FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 110.00 ( Q • ___ _ TT?Vt)_______ FIRE-PRESSURE TEST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRAd1ORft ATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Date Received l —C O : P 01! k ( 7 I0G — hone Contact for Permittin Owner's Nama Owner Phone Number tC Owner's Address 1 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number L Fee Simple Titleholder Address �, ,�,,4 '3JOB ADDRESS �'� �T. LOT# _________ SUBDIVISION PARCEL ID# 1 -7t,--7 $^ j0 CJ74C7p•-t -x, (U0-I AINCu FROM YRGYRR I7 I AA NO I0-:t) WORK PROPOSED El NEW CONSTR e ADD/ALT SIGN c MOVE O DEMOLISH INSTALL REPAIR PROPOSED USE EJ SFR COMM OTHER TYPE OF CONSTRUCTION O BLOCK FRAME STEEL OTHER DESCRIPTION OF WORK — BUILDING SIZE I I SQ FOOTAGE! I HEIGHT I mmmm mmnn BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY a W.R.E.C El PLUMBING Is ,d-\A/cy/: / Q MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING SPECIALTY O OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES =NO BUILDER COMPANY SIGNATURE REGISTERED LiLN FEE CURRENT Y!N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED LY/ N I FEE CURRENT j Y/N N Address I I License if PLUMBER COMPANY SIGNATURE REGISTERED Y! N FEE CURRENT YIN Address License# MECHANICAL COMPANY SIGNATURE I I REGISTERED L Y/ N FEE CURRENT Y/N Address 7 License# OTHER COMPANY SIGNATUR L mfr i c 9 REGISTERED Y/ N FEE CURRENT Y N Address 2722 (�� d /�, fLI/%� License# RESIDENTIAL Attach(2)Plot Plans;(2)sets Building Plans;( set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwvater Plans w!Silt Fence Installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans W/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Perrnit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""`PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) '" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- tsuui. I-urtnermore, IT the owner nas nlreo a contractor or contractors, ne is aavisea to nave the contractor(s) sign portions of the"contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due, will be identified at the time of IJcl l llllll ly. I l Ia IUI II ICI UI RJCI atuvii tl ldl 1 I dI ID�JvI ialiv,I I I I Ipdui Fa di id RCbuui ve Rm;vvCl y Fora I l luai ix Pdiu pl ivl iv receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to YIWl CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work wiii be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - nannrtrnont of rnuirnnmantal Drntartinn_eynrace Rovhoarte U/atlonrl Gracie and rn,irnnmantaii,Saneitn,n ...._..._..1 __.._...._ Lands,WaterNVastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Fraderal Aviation Authoritv-Runways I understand that the following restrictions apply to the use of fill: I eo of fill i not,II.—.s n Cln,.,,4 7n "'/",Unlmc a oI,, mitted '''._-..,.—.u.-'.---.,., r..r"„ - If the fill material isto be used in FloodZone 'A", it is understood that a drainage plan addressing a "compensating volume'will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or vioiations or any codes. Every permit issued snaii become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT ►al T n I VUR LCIV UCR GR AIV Mu 1 ORIYC i BEFORE RECORD;NG"i OUR NO 1;CE OF COMIIIIENCEIV EN . FLORIDA JURAT(F.S.117. OWNER OR AGE CONTRALTO ---- ,HSultted andbs to(or affi befo me this "r`^ Ilol eC rn to orj!6w�,f me h' Who is/are personal known to me or haaClayMfedllced ^4s/are personally(mown to me or healtie•e-preduQed ntiffcation. ~ as identfication. Notary Public Notary Public Commission iro. Commission ivo. °�ry' d Pdlded�t�teroi9+t0rida Name of Lary d,printed or stamped : r. ,glee,Pn P,y,ncacK o State of Florida �l _ a M� �:r:I s fir'DDL78759 Son DD678759 of�c L, 18/2pt a 2812011 Zephyrhills Fire Rescue 6907 Dairy Road,Zephyrhills, FL 33542 Fire Marshal Bus (813) 780-0041 Kerry Barnett Fax (813)780-0044 E-mail: kbamett(c).fire.zephyrhills.fl.us Plan Review#: 08-169 Project: Nestle/ZBW Number of Pages: 1 plus details packet Date: December 16,2008 I have received and reviewed plans for the sprinkler modification for the storage room and mezzanine located at 4330 Gall Blvd. and will allow this project to move forward. Payment for permit contractor acknowledges agreeing with items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. If system is down for more than 4 hours while replace/relocating sprinkler heads, Zephyrhills Fire Rescue shall be notified and fire watch shall be implemented by plant's safety officer. A log shall be kept in 30 minute increments of the area(s)in which the sprinkler system is down. This log shall be provided to Fire Marshal at final. Inspections Required: 1. Pressure test(20 or fewer heads system shall be pressure tested at normal working pressure for 2 hours) 2. Final. KERRY i ARNETT, FIRE MARSHAL * Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. FIRE SERVICE USER FEES Occupancy No.: Plan No.:No.: Contractor. � -� 1i4 f7/41 , / tr / Business Name: /) Billing Address: G 52R3/ /l Business Address: Business Phone No.: Billing Phone No.: .S S'rZ Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REAM FEES INSPECTION FEES PERMIT FALSE ALARM FEE oSSs N/C Annual N/C Sptklder let Alarm N/C am Pbh .06 of let RFkrapectiort N/C Slu lss tfi60 2nd Alum N/C (M r*man Chug.$25.00 2nd Rsinspsceon $100 Fke Punp $50 3rd Alarm N/C 0 Plan Rw4si ns OBL 3M Re#epeotion $250 Hoods $50 4th Alarm $100 48h Re•knspeotion $600 Fire Alarm $80 61h Alum $150 SPR#MCLER SYSTEMS (Bu i nss closed led LP On $50 6th Alarm $200 h -25 Heeds viol.Uats oarecIsd) Net"Gas $60 ooktPtwif $150 26ptusileads SPRISCLER SYSTEMS Fuel Tanks- per anic $50 STANDPWE SYSTEM Hydro Undergrounds $45 Spaddae $100 0 Per Riser $EiO Hydrostatic Teat ,,.to Firs Wake $500 FIB PUMP Acceptance Teat pet., n Camp Fire $25 ❑Par Pump $100 jJ Hydrant Flow Canlroped Bum $100 FIRE ALARM SYSTEM HoodiDuot $50 0-25 Devices $50 FINE ALARM SYSTEM Place of Assembly $50 Annuw 26 plus Devices $10D System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance $50 flammebie Applioanon $50 Aras.h Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fir.Wst moke WaS $15 per vwe Generator'KW $100 CO2 $50 LP Gas $25 per Wdc Generaicr'030 KW 150 Other $50 Natural Gas $25 per sp$em Bic-Hazard Waste $100 Annum KITCHEN EXHAUST FumiBatian Tenting $50 Hood/Ducts $50 HT0nt10)(la0r90dw $15 pertunt Torch Pot/Appiied $50 OTHER Fire Pump $45 Hat M $100 Annual LP khsieaedon per tank $50 Fire Suppression $30 Fuel Tank Inehiedon $50 System Acceptance (Per Tank) $50 Eanust HoodiDuct $30 Nadxal Gee kat.Nadon $50 Re.krspection DBL (Per System) (other than annual) Spray Booth $50 ❑Inspection scheduled DBL and c anceSed less then 24 hours 8 Construction Inep. N/C Emergency Vehicle Aa $50 -, FALSE ALARM PLANS TOTAL INSPECTION TOTAL PER MIT TOTAL TOTAL GRAND TOTAL I 2i '_ Comments: Date: 6 insp&ctor SUBMITTAL DATA: ZEPHYRHILLS BOTTLED WATER 4330 20th ST. ZEPHYRHILLS, FLORIDA DECEMBER 8,2008 BENEFICIAL FIRE PROTECTION, INC. 12522 US Highway 301 N. Suite 6 Thonotosassa, Florida 33592 Phone: (813) 986-5819 Fax: (813) 986-5837 State Certification: #45018800011989 SUBMITTED PLAN(S)HAVE BEEN REVIEWED BY ZEPHYRHU-LS HAL'S OFFICE Date: d Reviewer: INDEX SPRINKLER HEADS: Reliable 3/a" 286* Brass Upright R1027 -- 8.0 K-Factor PIPE: Black Schedule 10 Pipe Black Schedule 40 Pipe Galvanized Schedule 10 Pipe FITTINGS: Grooved Fittings Grooved Couplings Threaded Fittings MISC: Hanger Rings Hanger Fasteners No Text Bulletin 110 Rev.S Model GI'e ii co Automatic Sprinklers Spray Upright, Spray Pendent o And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from Upright Pendent copper based alloys for maximum corrosion protection. Lead plated,wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright - This deflector configuration is Small Orifice Upright Conventional normally used with exposed piping installations.Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is Application and Installation normally used where the space above the piping is Standard sprinklers are used in fixed fire protection limited or where a concealed piping installation is systems:Wet, Dry, Deluge or Preaction.Care must be employed. The discharge characteristics of the exercised that the orifice sizes, temperature ratings, standard pendent are virtually identical to the deflector styles and sprinkler spacings are in standard upright as described above, accordance with the latest published standards of the National Fire Protection Association or the approving Large and Small Orifice—By varying the orifice size, authority having jurisdiction. a large or small orifice sprinkler is created that will The sprinklers must be installed with the Reliable distribute as much as 40% more water or 65% less Model D Sprinkler Wrench. Any other type of wrench water than the normal 1/2" (15mm)orifice sprinkler. may damage the sprinkler. The approvals or listings of Reliable Automatic Conventional—This deflector configuration is used Sprinklers by major approving organizations are primarily in those countries where the LPC installation shown in the tabulated list provided on the back of this rules have precedence. The sprinkler is designed to bulletin. distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, =Patent No.4,440,234 ordinary and extra-high hazard installations. The Reliable Automatic Sprinkler Co.,Inc.,525 North MacQuesten Parkway,Mount Vernon,New York 10552 Technical Data "K"Factor Sprinkler Identification Sprinkler Number(SIN) Sprinkler Type US Metric Height Approvals SSU SSP Standard-Upright(SSU)and Pendent(SSP) Deflectors Marked to Indicate Position z"(1b mm)Standard Orifice with} NPT(Ry)Thread 5.62 81.0 1 2 " (73 mm) 1,2,3,4,5,6,7 R1025 R1015 % '(11 mm)Small Orifice with)"NPT(Ry)Thread 4.24 61.0 2 re" (73 mm) 1,3,7 R1023 R1013 "(10 mm)Small Orifice with y"NPT(R)2)Thread 2.82 40.6 2'/e" (73 mm) 1,2,3,7 81021 R1011 :."(8 mm)Small Orifice with)"NPT(Ry)Thread 1.98 28.5 2%" (73 mm) 1,3,7 R1022 R1012 (20 mm)Large Orifice with y"NPT(R v)Thread 7.96 114.7 2%" (73 mm) 1,2,3,7 R1026 R1016 %2"(20 mm)Large Orifice with%"NPT(R%)Thread 8.20 118.2 2's,e (75 mm) 1,2,3,7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 81027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4,5,6 81024 R1014 Conventional—Installed in U ri ht or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73 mm 5 R1074 15mm Standard Orifice with(A t,) Thread 5.62 81.0 73 mm 4,5,6 R1075 20mm XHH with(R%)Thread 8.20 118.2 75.4 mm 4,5 R1077 Temperature Ratin s Maintenance Maximum Model G Sprinklers should be inspected quarterly and the Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do Rating Temperature Frame tit not clean sprinklers with soap and water,ammonia or any other Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted Ordinary 135 57 100 38 Black (other than factory applied)or damaged in any way.A stock of Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace- Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation, High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or Use sprinkler rating as identified on operating parts. non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation.Any other type of wrench may damage the sprinkler. Finishes(1) Standard Finishes _ Approval Organizations Bronze All Temperature Ratings 1. Underwriters Laboratories, Inc. Chrome All Temperature Ratings 2. Factory Mutual Research Corporation White 12) —All Temperature Ratings 3. Underwriters' Laboratories of Canada Only Frame and Deflector are Painted 4. Loss Prevention Council Special Application Finishes 5. Pleniere Assemblee Bright Brass Plated —Only frame,deflector and cap are plated. 135°F(57°C),165°F 6. VdS SchBS&A No. 587-75-SA 8 -g (74°C).212°F(100°C)Temp.Rating. 7. N.Y.C. MEA 58- 3-E 75 SA or N.Y.C. MEA 258-93-E Black Plated —Only frame,deflector and cap are plated.All Temp.Ratings. Polyester Coated 12) —Only frame and deflector are coated. Lead Plated —165°F(74°C).212°F(100°C)and 286°F(141°C)Temp.Ratings. Ordering Information Wax-Coated 131 —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. Specify Wax-Coated Over 1. Model G Lead Plated 13) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. 2. Deflector •Upright il Other colors and finishes are available.Consult factory for details. •Pendent 12) UL listed and NYC MEA Approved only. •Conventional (3) 212°F(100°C)brown wax may be used on 286°F(141°C) 3. Nominal Orifice sprinklers when maximum ambient temperatures do not exceed 150°F 4. Inlet Thread (66°C).UL Listed,FM Approved,NYC MEA 258-93-E. 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Rellabld (800)431-1588 Sales Offices a°`t`u (800)848-6051 Sales Fax Paper (914)668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.PrMed inU.S.A. 11104 P/N 9999970005 Schedu1e=10@/Schedu1e=40@ Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-I0/Schedule-40 sprinkler pipe you get a UL listed and FM approved product.Although these products do not require separate approvals,Schedule-I0/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10(1'/a"—8")pipe and Sch-40(I"—2'/,")pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ Wt/Lift(21') WI/Lift(24') WI/Lift(25' Schedule-10/Schedule-40 product can be In;mm In;mm Lbs/Ft,Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg "hot-dip"galvanized to meet FM 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 requirements for dry systems in 25 26.6 2.5 3.05 70 1,120 1,280 1,334 accordance with the zinc coating specifications of ASTM A-123. 1W 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 436 4.36 51 1,103 1,260 1,313 • • • 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean,durable surface.It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 paint-ready for custom color applications 2,/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube&Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ Wt/Lift(21') Wt/Lift(24') Wt/Lift(25' mula,"ABF'.In scientific laboratory In;mm In:mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg test,ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 walls, thereby delaying or possibly pre- 1'/d 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion (MIC)when the 11/2^ 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 . . - 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets"Buy American"requirement 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA,Canada and Mexico. 3' 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule-10/Schedule-40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209 compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A-135,and NFPA 13.Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: •Welded Outlets •Hydrostatic Pressure Listed Approved Listed •Side Wall Rupture •Vibration Test tqCIDFlow Control 16100 S. Lathrop• Harvey, IL 60426 Customer Service: allied 11350 Norcom Rd. •Philadelphia, PA 19154 (800)882-5543 TUBE&CONDUIT 2525 N.27th Ave. • Phoenix,AZ 85009 Fax 708-339-1806 S5 - 3 ra SHURJOINT •- • •- •• WWW-snurjoint_com Approvals Products for Fire Protection Piping Systems COUPLINGS AND FITTINGS Listing Pipe Rated Working Pressure Pipe Notes(See Coupling and Shurjoint Pub. Approval Size Range Wall psi Fitting Notes on page Product Model No. Agency Inches Standard I Light 13-14) IPS Carbon Steel Grooved Couplings #7705 Flexible Coupling 1"-h" 300 300 UL 8"(770511) 450 450 1.2-1,14,15 10"-12" 175 175 C-01 0 1"-8" 300 300 FM 8"(770511) 450 450 2-2,18,19 10-12" 250 250 #7707 Flexible Coupling 3/4"-I 1'4" 500 500 2"- UL 500 450 1,3-1,14,17 l0--16" 300 - 18"-24" 250 - 0C-02 1 1/2"-]0" 500 500 FM 12" 300 300 3-2,18,19 14"-22" 175 175 24" 250 250 #7771 Rigid Coupling 2"-8" 300 300 UL 10-12" 175 175 1,5-1, 14"-20" --- 300 22"-24" --- 250 1 1/2" 500 500 C-05 2"-8" 300 500 FM 10" 200 200 5-2, 12" 300 300 14"-24" 175 175 #Z07 Angle Pad Coupling 1 1/4"-4" 500 500 UL 5"-8" 400 400 1,8-1 10" 350 350 12" - - C-06 I U4"-4" 500 500 FM 5"-8" 400 400 8-2, 10" 350 350 12" 350 350 #K9 Lightweight Rigid Coupling UL 1-1/4"-8" 300 300 1,4-1, 8"(K-9H) 350 300 0 G-01 FM 300 300 4-2, 8"(K-91) 300 300 I/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT • -• -- •• www.shurjoint-cwm #Z05 Angle Pad Rigid Coupling UL 11/4"-8" 350 350 1.7-I G-03 FM 1 1/4"-8" 350 350 7-2 #7706 Reducing Coupling UL 2 x1-12 300 300 1.10-1 O 8"x6" C-07 FM 2"x 1.12" 300 300 10-2 8•,x 6,. #R20 Rigid Coupling O UL 1-1/4"-6" 300 300 1,6-1 C-13 FM 1-1/4"-6" 300 300 6-2, IPS Carbon Steel Grooved Flanges #7041 Flange-ANSI 125/150 UL 2"-8" 175 175 1,9-I O D-01 FM 2"-24" 175 175 9-2 #7043 Flange-ANSI 300 UL 2"-12" 300 300 1 D-03 FM 2"-12" 300 300 IPS Carbon Steel Hole Cut Products #7721 Mech.Tee,Threaded Outlet UL 2 x 1/2 300 300 1,13 D 8" x 4" F-01 FM 2"x 1/2"- 300 300 -- "x8"x4" #7722 Mech.Tee,Grooved Outlet UL 3"x 1 1/2"- 300 300 1,13 F-02 FM 3"x 1 1/2"- 300 300 2/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products a 1 800 746-GROOVED a Las Vegas,Nevada USA e www.shurjoint.com SHURJOINT ' -, -•• wow s1su nt corn #C-7T Outlet Couplings 1-1 1//2"x 2"- UL 300 300 I 6"x t-12' C-10 FM 1-1i2"x 1/2- 300 300 - 6"x #C-7G Outlet Couplings UL 2"x 1" 300 300 1. 6"x 2" C-10 FM 2' x 1' 300 300 - 6"x2" #723 Saddle Let UL 11/4"xl/2"- 300 300 1,12-1, 3"x 1" F-03 1 1/4"x 1/2"- FM 300 300 12-2 IPS Carbon Steel Grooved Fittings #901 Short Radius 90"Elbow UL 2"-8" 300 300 I, G-02 FM 2"-8" 300 300 -- #903 Short Radius Tee UL 2"-8" 300 300 1, G-02 FM 2"-8" 300 300 -- #7110 90"Elbow UL 1"-18" 300 300 1 20"-24" 250 250 1 -8" 500 500 E-02 10"-12" 300 300 FM 175 -- 14"-18",24" 175 20" 250 250 3/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com to SHURJOINT • -, .. •• www.shur$Pint.Cam', #71 1 l 45"Elbow 1-1/4"-I8" 300 300 UL 1, 20",24" 250 250 E-02 I-1/4"-8" 500 500 10"-12: 300 300 FM 175 14 -18 ,24" 175 20" 250 250 #71I 0DR Drain Elbow UL 2"-6" 300 300 1, G-05 FM 2"-6" 300 300 -- #71 I0LR 1.5D Elbows UL 2"—8" 300 300 1 E-04 FM 2"-8" 300 300 -- #7112 22-1/2'Elbow UL 1-1/4" 500 500 1 1-1/2"-8" 300 300 E-04 FM 2"-8" 300 300 -- #7113 11-1/4"Elbow UL 2"-8" 300 300 1 E-02 FM 2 -8" 300 300 -- #7120 Tee UL 1-1/4"—18" 300 300 1 20 -24" 250 250 E-05 1-1/4"-8" 500 500 FM 10"-14" 300 300 -- 16" 175 175 #7121 Reducing Tee UL 2"x 1-1/2"—12"x 300 300 1 0" E-06 FM 2 x 1 1/2" 300 300 -- 6"x4" 4/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com IFSHUIJOINT --• .. •• w shurjoim.Corn #899 End All Fitting UL 11/4 x 12" 300 300 1, 2-1/2"x I" G-06 FM I 1/4"x 1 r2"- 300 300 2-1/2"x I" IPS Carbon Steel Outlet Fittings #71 Female Threaded Outlet Outlet x Header Fitting Yz"x I"-8", 1"x l'''A"-8" 1,/„x2"_8„ UL 300 300 1, 2"x 2"-8" 2%"x2%"-8" 2%(76.1)"x2Ya"-8" 3"x 3"-8" H-01 4"x4"-8" /z".,/<,I„x 1 _8 I'/.",1Yax2"-8" FM 300 300 2'/z"x 3"-8 3"x4"-8" 4"x5"-8" #72C Cut Grooved Outlet 2"x2 -8" Fittings 2-1/2"x2-l/2"--8" UL 3"x 3"-8" 300 300 1, 6"x6"x8" 8x 8x10 8"x 10" H-02 2-1/2"x3"-8 3"x4"-8" FM 4"x 5"-8" 300 300 6"x 8" 8"x 10" #72R Roll Grooved Outlet 1-1/4"x 1-1/2"-8" Fittings 1-1/2"x 1-1/2"-8" UL 2"x2"-8" 300 300 1, 2-1/2"x2-l/2"--8 4"x 4"-8" H-03 1-1/4"x 1-1/2"-8" 1-1/2"x2"- 8" FM 2' s 2-1/2--B" 300 300 2-1/2"x3"-8 3"x4"-8" 4"x 5"-8" 7/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT • - . • - .. www,shurjo n1.com #74 Universal Threaded 1/2"x 1"-8" Outlet Fitting 3/4"x I"-8" UL I"x 1-1/4"—1-1/2" 300 300 1, SI"x 2" 2-1/2" H-04 1/2"x 1"-8" 3/4"x 1"-8" FM I"x 1-1'4"- 1-1/2" 300 300 -- 1"x2"-2-l/2" 1"x3"_8„ Ductile Iron Fittings #811 90"Elbow UL l'2'-2-12" 300 300 1 1-01 FM 1/2"-2-1'2" 300 300 -- #812 Reducing 90"Elbow 3/4"x 1/2"— UL 300 300 2-1/2"x 2" 1 1-01 3/4"x 1/2"- FM 300 300 -- 2-l/2"x2" 2" #813 45°Elbow UL 1/2"-2-1/2" 300 300 1 1-01 FM 1/2"-2-1/2" 300 300 -- #814 Straight Tee UL 1/2"-2-1/2" 300 300 1 1-01 FM 1/2"-2-1/2" 300 300 -- #815 Reducing Tee UL 3/4"-2-1/2" 300 300 1 1-01 3/4"x3/4"x1/2" FM - 300 300 -- 2-1/2"x2"x3/4" 8/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT® #816 Reducing Coupling 3/4"x1/2"- UL 300 300 1 2-1/2"x 2" 1-01 3/4 x 1/2"- FM 300 300 -- 2"x 1-12" #817 Cross UL 1--2" 300 300 1 I-01 I!2'-2" FM 300 300 -- 1-1/4"xl"-2"xl" #818 Straight Coupling UL I/2"-2-1/2" 300 300 I 1-01 FM 1/2"-2-1/2" 300 300 -- #819 Plug UL I/2"-2" 300 300 1 1-01 FM 1/2"-2" 300 300 -- #820 Caps UL 1/2"-2-1/2" 300 300 I, I-01 FM 1/2"-2-1/2" 300 300 -- #825 Extension Pieces 1/2"x 1-1/2"— UL "x 2" 300 300 1, 3/4 1-01 1/2"x 1-I/2"L- FM 300 300 -- 3/4"x 2"L 9/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com t, SHURJOINT® --• --•• Stainless Steel Grooved Couplings #SS-7 Rigid Coupling O UL I I!4"-8" 300 300 1.20 K-01 FM 11/4"-8" 300 300 -- #SS-8 Flexible Coupling UL 1 5" 300 300 1 K-03 6" 250 250 Stainless Steel Grooved Flange #SS-41 Flange UL 2"-6" 175 175 1, O K 08 FM 2"-6" 175 175 Stainless Steel Grooved Fittings #SS-10 90°Elbow UL 1"-8" 300 300 1, K-06 FM l"-S" 300 300 -- #SS-I1 45'Elbow UL 1"-8" 300 1, K-06 FM 1"-8" 300 300 -- #SS-20 Tee UL 1 -8" 300 300 1, K-06 FM 1"-6" 300 300 -- 11/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT •-• •- •• wwwawiornt eon #SS-60 Cap UL 1"-8" 300 300 1, K-06 FM I"-8" 300 300 -- #SS-21 Reducing Tee UL 3"x2 1/2"- 300 300 1, 4"x2 1/2" K-07 FM 3"x2 1/2"- 300 300 -- 4"x2 1/2" /SS-2I F Reducing Tee UL 3"x2"- 300 300 1, 4"x2" K-07 FM 3x2" , 300 300 -- 4 #SS-50 Concentric Reducer UL 3"x2-1/2"— 300 300 1, 4"x2-1/2" K-07 2-1/2"x2-1/2" FM 3"x2-1/2" 175 175 -- 4"x2-1/2" #SS-50F Concentric 2-1/2 x 2„ Reducer UL 3"x 2" 300 300 1, 4"x2" K-07 2-1/2"x 2" FM 3"x 2" 175 175 -- 4"x2" #SS-80 Flange Adapter UL 2"-8" 300 300 1, K-09 FM 2"-8" 300 300 -- #SS-723 Mechanical Tee 1 1/4"xl/2"- UL 300 300 1, 2"xl" K-10 I 1/4"x 1/2"- FM 300 300 -- 2"x I' 12/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT •-• • -•• sIsugrnt coin Couplings and Fittings Notes 1. MEA Approved#322-06-E. 2. 2-1)t t,Listed at 300 psi on the following sizes&pipe. I-I/4"-4"on XL,XL-II pipe,Dyna-Flow,Super-Flo pipe manufactured by Allied Tube&Conduit Corp,1-1/4"-6"on BS 1387(M),British Standard Medium Steel pipe, 1-I/2"-3"on Eddy Flow pipe.,1-1/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co. I-114"-2"on Fire-Line Threadable pipe manufactured by Western International Forest Products Inc. UL Listed at 175 psi on the following sizes&pipes. I-1!2"-3"on Eddy Flow Pipe manufactured by Bull Moose Tube Co, 1-1/4"—4"on Fire-Line Flow pipe manufactured by Western International Forest Products Inc.. 1-1/4"-2"&3"on SPS pipe manufactured by Yieh Phui Enterprise Co.,Ltd. 1-1/4"--3"on Sch.5 pipe,10"on Sch.10(0.188 in)pipe,12"on Sch.30(0.330 in)pipe. 2-2)FM approved at 300 psi on the following sizes&pipes. on BS 1387M or heavier grade pipe. I"-4"on Dyna-Flow,Super-Flow(Allied)pipe I"-2"&3"on Super 40,Super-XL(Allied)pipe. I"-3"on XL-11(Allied)pipe I'—2"on BLT,Dyna Thread(American Tube),Fire-Thread,Eddylite(Bull Moose),TL(Central),LS pipe, 1-I!2"-4"on Eddy Flow(Bull Moose Tube)pipe 1-1/4"&1-1!2"on Fire-Flow pipe FM approved at 175 psi on the following sizes&pipes. 1"-2"on WST(Weatland),Ultra Eddy(Bull Moose)pipe. 3. 3-1)UL Listed on the following sizes&pipe. At 500 psi in 2-1/2",5"-6"on BS1387(M),British Standard Medium Steel pipe pipe, At 450 psi in 1-1/2"&4"on Dyna-Flow pipe manufactured by Allied Tube&Conduit Corp, At 300 psi in size 10"&12"on sch. 10(0.188 in)pipe,14"&16"on Sch.30(0.375 in)pipe, At 250 psi in 18 -24"on Sch.20(0.375 in)pipe. 3-2)FM approved on the following sizes&pipe. At 500 psi in 2-1/2",5"-6"on BSI 387 medium or heavy grade pipe 4. 4-1)UL Listed at 300 psi on the following sizes&pipe. I-1/4"-8",3.OOD,6.5OD on BS 1387(M),British Standard Medium Steel pipe pipe, 1-1/4"&2"on Eddylite pipe manufactured by Bull Moose Tube Co, 1-1/4"—2"on Fine-Line Threadable pipe manufactured by Western International Forest Products Inc., 2"on Eddythread 40 pipe manufactured by Bull Moose Tube Co. UL Listed at 175 psi on the following sizes&pipes. 2"—3"on XL-11,XL pipe manufactured by Allied Tube&Conduit Corp, 2"—4"on Dyna-Flow,Super-Flo pipe manufactured by Allied Tube&Conduit Corp, 1-1/4"-4"on ELF pipe manufactured by Western International Forest Products Inc., 1-1/4",2"-3"on SPS pipe manufactured by Yieh Phui Enterprise Co.,Ltd., 1-1/4",2"-3"on Sch.5 pipe. 4-2)FM approved at 300 psi on the following sizes&pipes. 2-1/2",5"-6"on BS 1387(M)medium or heavy grade pipe, 1-1/4",1-1/2"&4"on Fire-Flow(Allied)pipe, I-1/2"&2"on Fire-Thread pipe, I"---3"on Super40,Super-XL pipe, 1"-2"on TL(Central)&LS pipe. FM approved at 175 psi on the following sizes&pipes. 1-1/4"-3"on XL-11(Allied) pipe, 1-1/4"-2",3"-4"on BS1387 pipe, 1-1/4"-4"on Eddy-Flow,Super-Flo pipe, 1-1/4"-2"on BLT,Eddylite,WST(Wheatland),Gal-5(IDOD Systems)pipe, I"-2"on Ultra Eddy(Bull Moose)pipe, 1-1/2"—4"on Eddy-Flow pipe. 5. 5-1)UL Listed at 300 psi on the following sizes&pipes. 2"-6"on BSI387(M),British Standard Medium Steel pipe pipe, 14"&16"on Sch.30 pipe, 18"&20"on Sch.20 pipe. UL Listed at250 psi in size 22"&24"on Sch.20 pipe. 5-2)FM approved at 175 psi in size 22"&24"on Sch.20 pipe. 6. 6-1)UL Listed at 300 psi on the following sizes&pipe. 1-1/4-6"on BS 1387 pipe,1-1/4"--3"on Super 40,Super-XL pipe,1-1/4"—4"on Dyna-Flow,Super-Flo pipe,1-1/4 -1-1/2"on Fire-Line Flow pipe,1-1/4"—2"on Fire-Thread pipe&Eddlylite pipe. UL Listed at 175 psi in size 1-1/4"-2"on Sch.5 pipe. 6-2)FM approved at 300 psi on the following sizes&pipes. I-1/4"-6"on BS1387 pipe, 1-1/4"—3"on Super 40,Super-XL(Allied)pipe, I"-.4"on Dyna-Flow,Super-Flo(Allied)pipe, 1"-2"on Ultra Eddy(Bull Moose)pipe, 13/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products . 1 800 746-GROOVED e Las Vegas,Nevada USA a www.shurjoint.com T SHURJOINT ` WMRv.$hUrlplrFt CAin 1-112"-2"on Fire-Thread pipe, 1-1/4"-2"on Eddylite(Bull Moose),WST(Wheatland)pipe. 7. 7-1)UL Listed at 350 psi on the following sizes&pipe. on BSI387(M)British Standard Medium Steel pipe pipe 2"-4"on Dyna-Flow.Super-Flo pipe manufactured by Allied Tube&Conduit Corp, UL Listed at 300 psi on the following sizes&pipe. I-1/4"-2"on XL,BLT,WLT pipemanufactured by Allied Tube&Conduit Corp, 1-1'4"-2"on WLS manufactured by Wheatland Tube Co i-1!4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co. I-1!4"-2"on Fire-Line Threadable pipe manufactured by Western International Forest Products Inc.1-1/4"-1-1 i2"on Dyna-Flow. Super-Flo pipe manufactured by Allied Tube&Conduit Corp, 1-1!4"-4"on Mega-Flow pipe manufactured by Wheatland Tube Co. I-1 4"on Eddy Flow pipe manufactured by Bull Mosose Tube Co. 3"&4"on EZ-Flow pipe manufactured by Northwest Pipe Co., 1-I!4"&2"on MT pipe manufactured by Wheatland Tube Co. UL Listed at 175 psi on the following sizes&pipes. 1-1/2"-3"on Eddy Flow pipe manufactured by Bull Mosose Tube Co., I-1/4"-2"on Sch.5 pipe, 6"on EZ-Flow pipe manufactured by Northwest Pipe Co.,. 7-2)FM approved at 350 psi in size 1-1/4"on XL pipe. FM approved at 300 psi on the following sizes&pipes. 2"-4"on Dyna-Flow,Super-Flo pipe, l-1/4"--4"on Mega-Flow pipe. FM approved at 175 psi on the following sizes&pipes. 2"-4"on Dyna-Flow.Super-Flo pipe, 1-1/4"-4"on Mega-Flow pipe. 1-112"-3"on Eddy Flow,Fire-Thread pipe. 8. 8-1)UL listed at 300 psi on the following sizes&pipe. I-I/4"--4"on Dyna-Flow manufactured by Allied Tube&Conduit Corp.,and EF pipe manufactured by Bull Moose Tube Co.,and Mega.Flow pipe manufactured by Wheatland Tube Co. 3"-4"on EZ-Flow pipe manufactured by Northwest Pipe co 1-I/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co.,and MLT,WLS pipe manufactured by Wheatland Tube Co. UL Listed at 175 psi on the following sizes&pipe. 1-1/4"-4"on Eddy Flow pipe manufactured by Bull Moose Tube Co. I-1/4"-2"on Sch.5 pipe, 6"on EZ-Flow pipe manufactured by Northwest Pipe Co. 8-2)FM approved at 350 psi in size 1-1/4"-2"on XL pipe. FM approved at 300 psi in size 1-1/4"--4"on Mega-Flow pipe. FM approved at 175 psi in size 1-1/2"-3"on Fire-Thread,Eddy Flow pipe. 9. 9-1)EL listed at 175 psi on the following pipe. 3"OD,4"-5"on BS 1387(M)British Standard Medium Steel pipe pipe, 12"on Sch.30(0.330 in)pipe.. 10"on Sch.10(0.188 in)pipe. 9-2) FM approved at 175 psi on the following pipe. 2-1/2.4 in.British Standard BS 1387 medium or heavy pipe. 2"-12",14",16"24"Min schedule cut groove pipe to be joined:8 in.or smaller Schedule 40. 2"—12",14",16"24"Min schedule rolled groove pipe to be joined:8 in.or smaller Schedule 10. 10. 10-1)UL listed at 300 psi in size 3"x2"-2-1/2",4"x2-1/2"-3",6"x4"on BS1387 and 10-2)FM approved at 300 psi on BSI 387(M)or heavy grade pipe. 11. UL listed at 175 psi in size 1-1/4"--2"on BS1387 pipe. 12. 12-I)UL listed at 300 psi in size 1-1/4"-2-1/2"on XL,Super-Flo pipe,175 psi in size 1-1/4"-2-1/2"on Dyna-Flow,XL-l1,BS1387 pipe. 12-2)FM approved at 300 psi in size 1-1/4"-2-1/2"on Dyna-Flow,XL,Super-Flo(Allied)pipe,1-1/4"—2"on BLT(Allied)pipe,TL (Central),Eddylite(Bull Moose),WLS,LS (Wheatland)pipe. 13. 13-1)UL listed at 300 psi in size 2"x 2%"-8"x 4"on BS1387 pipe 13-2)UL listed at 300 psi in size 3"x I',4"-8"x 4"on BS1387 pipe 14,light wall pipe shall be of the minimum wall thickness 0.188 in.Sch.10. 15.Rolled and Cut grooved basked on Sch.30(0330")pipe. 16.Rolled and Cut grooved based on Sch.20(0.375 wall thickness pipe) 17.Rolled and Cut grooved based on Sch.30(0.375 wall thickness pipe) 18.Minimum schedule cut groove pipe to be joined:6"in or smaller-Sch.40;8"in or larger—Sch.30 19.Minimum schedule roll grooved pipe to be joined:6"or smaller—Sch.10,8 and 10"-0.188 in wall;12"-0.250 in wall. 20.UL listed at 300 psi in size 76.1 mm,139.7mm,165.1 mm on Sch.10S,40S pipe. 21.a)Provides a rigid transition between flanged components and a grooved system. b)Min schedule cut groove pipe to be joined:8 inches or smaller-Sch.40 c)Min schedule rolled groove pipe to be joined:8 inches or smaller—Sch.10. 14/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com t — FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The knurled insert nut that allows a vertical adjustment after installation,is tapped to NFPA reduced rod size standards. Fig.141F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.141 ,"to 8"sizes only.Complies with Federal Specification A-A-1192A(Type 10),Manufacturers'Standardization Society SP-69(Type 10)and NFPA Fig. 141 PRE-GALVANIZED standards for reduced rod sizes. Fig. 141F PRE-GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING Pipe S e Adj- Max.Rec.Wt Each %_—A Size A B C D E Load/lbs. (in lbs.) i' 3/e 1'/8 1'/,E 2'/4 3`/,6 300 10' , .c 1'"i,t 1'/ 2'/2 31/,6 300 .10 I 1 15/5 1 2/2 33/,6 300 .10 1 I I C 1'/4 '/a 1,5/,e 1'/e 2.'/,= 3`/,6 300 .11 ' B y ` 1'I /8 2118 1'/.E 3'/e 3'/a 300 .11 ' ` 2 '/5 2'/, 1'/e 3l, 43/s 300 .14 ,/ D / 2'/:_ '/8 2'/4 1'/4 3"/1 5 525 .19 E 3 31, 2'/8 1'/6 33/4 5`/,6 525 .23 31!2 3/8 378 1'/E 45/,6 65/,6 525 .25 4 '7 3'/8 11/2 4'/2 7 650 .30 5 1/2 45/5 1'7 5'/e 8'/6. 1000 .50 6 1/2 55/8 21/4 62 9j3/16 1000 .58 8 1/2 613/,5 2'/,E 715/,; 121/4 1000 .90 FM L Note: bordering Fig. 141F felt lined hangers for pipe sizes 01 3/2"or under,order the next largest size to allow for the thickness of the felt lining. MATERIAL: Low carbon steel FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The rig , knurled insert nut,allows for vertical adjustment after installation 4& Fig. 151F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.151 21/2' to 8"sizes only.Complies with Federal Specification A-A-1192A (Type 10),and Manufacturers'Standardization Society SP-69(Type 10). Fig. 151 PRE-GALVANIZED ORDERING: Specify pipe size and figure number. Fig. 151F PRE-GALVANIZED WITH FELT LINING pe Rod Max:Re i~c.W Each A Size SAe B Cl� D E LoadtlbL; ftn Ibs.j f:•� 2'/2 1/2 2'/4 11/4 311/,6 51/8 600 .33 3 1/2 3'/6 11'8 4 57/e 600 .35 3/ /2 35/8 1,7 45/, 65/8 600 .37 ♦'r 4 5/6 3'/6 11/4 415/,5 7'/8 1000 .48 u B 5 5/6 4'/e 17 55/e 81/2 1000 .57 6 # '.5 3/4 55/,6 2 _611/16101/8 1250 1.06 = 8 ' 3/4 6'5/,6 25/8 85/,6 12/8 1250 1.32 s Note: If ordering Fig.131F felt lined hangers for pipe sizes of 3'/2"or under,order the next ` largest size to allow for the thickness of the felt lining. .FM UL MATERIAL: f.nw carbon stP�1 PHD Manufacturing, Inc. •44018 Columbiana-Waterford Road•Columbiana, OH 44408 Toll Free(800)321-2736•Phone:(330)482-9256•Fax: (330)482-2763•www.phd-mfg.com __ A asmms Hg..35O. FUNCTION: Designed for attaching hanger rod to the top flange of a beam or bar joist,where the flange thickness does not exceed 3/4 inch.The U 2LIVL `' `.LV.L open U design permits rod adjustment.The universal design of the 3/ri Fig.350 allows it to be used in an inverted position on the bottom flange of a beam as well. APPROVALS: Underwriters'Laboratories listed.Factory Mutual approved / " and '/2' sizes only. Complies with Federal Specification A-A-1192A (Type 19)and Manufacturers'Standardization Society SP-69(Type 19).When used in an inverted position on the bottom of a beam flange the 3/ti Fig.350 also complies with Federal Specification A-A- 1192A(Type 23)and Manufacturers'Standardization Society SP-69 (Type 23) MATERIAL: Ductile iron with hardened steel cup point set screw FINISH: Plain or electro-galvanized a%4•/ / ORDERING: Specify rod size,finish and figure number. A F_=a Rod Max. Size Pipe Max_Rec._ Wt.;Each E r A B C D E Size ©adllbs. (in'.lbs) Bam' 03/8 1 11/2 15/8 1/2 4 400 .33 1/2 1 1'/2 1 /,6 '/2 8 500 .34 5/8 1'/,6 11/2 17/8 5/8 8 600 .39 © FM 3/4 15/16 13/4 23/8 5/8 8 800 .63 '/8 15/,6 13/4 23/8 5/8 8 1200 .60 Note: See MSS SP-69 specs for proper set screw torque values. d Reversible design approved for bottom beam use. PHD Manufacturing,Inc. •44018 Columbiana-Waterford Road • Columbiana, OH 44408 Toll Free(800)321-2736•Phone: (330)482-9256•Fax: (330)482-2763•www.phdanfg.coni