HomeMy WebLinkAbout09-8730 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 8730
BUILDING PERMIT
Permit Number: 8730 Address: 39806 COGHILL LOOP LT 168
Permit Type: PARK MODEL SETUP ZEPHYRHILLS, FL.
Class of Work: PARK MODEL SET-UP Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: MAJESTIC OAKS
Est. Value: Parcel Number: 24-26-21-0030-00000-1460
Improv. Cost: 15,650.00
Date Issued: 1/21/2009 Name: MAJESTIC OAKS LLC
Total Fees: 175.00 Address: 6991 E. CAMELBACK RD
Amount Paid: 175.00 SCOTTSDALE AZ 85251
Date Paid: 1/21/2009 Phone: (813)783-3477
Work Desc: PARK MODEL SET UP 14 X 36
_ '. n
BUTTERFIELD MOBILE HOME SETUP MOBILE HOME SET-UP 60.00 MOBILE HOME x o €4 , �do°;..
ELECTRICAL 40.00
CRANDALL,RICHARD MOBILE HOME PLUMBING 40.00 MOBILE HOME MECHANICAL 35.00
BUTTERFIELD MOBILE HOME SETUP
BAHR'S PROPANE GAS&A/C, INC.
( TO ?
PARK MODEL MECHANICAL
PARK MODEL PLUMBING
PARK MODEL SET-UP
PARK MODEL ELECTRIC
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
CONTRACTOfr≤IGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
b IJ-IDU-UULU %-ALy UI £ I lyl I III10 I VI 11111„r'+ v„
Building Department £1.3o
Date Received r0 I Phone Contact for Permitting 0 13 I t5&, O
tiiillllllllllllttll
Owner's Name NC F L ! L L C j Owner Phone Number �)3 7�3 3`l 7
1
Owner's Address C9i9/ - ( ( melbO f 12" Owner Phone Number
Fee Simple Titleholder Name d / Z 1 Owner Phone Number
Fee Simple Titleholder Address / / /
JOB ADDRESS 3 C'�d)6(P Co / 7 I /1 L �' LOT# (_U
SUBDIVISION 1 a �t: PARCEL ID# 2 q-2 , /-OO C)-U 60(6 ( Yv O
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR e ADD/ALT El SIGN Q MOVE DEMOLISH
INSTALL REPAIR
PROPOSED USE jjj SFR COMM O OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL O OTHER /
DESCRIPTION OF WORK `'C ( � +
BUILDING SIZE / / X3 u SQ FOOTAGE HEIGHT
BUILDING $ j� C� 6 �� J VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ / r+ c, AMP SERVICE PROGRESS ENERGY W.R.E.C.
SO .
PLUMBING $ "s
MECHANICAL $ 2S U`; VALUATION OF MECHANICAL INSTALLATION
GAS ROOFING El SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA OYES QNO
BUILDER Jam/ COMPANY L
SIGNATURE REGISTERED Y/ N FEE CURRE T Y/N
Address E=!!
�SU License# jELECTRICIANCOMPANY � { (A. , L 1SIGNATUREREGISTERED Y/ N FEE CURRENT p Y/N
G S �fH S 'PC Ze �-1 )(
tii t 53rf'G LicenseAe# C R oo( Z �1 (Q
Address
PLUMBER COMPANY �Ufifer 1!f` '( ('elf—1
SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/N
Address /629 C6 f/ (3)V"C,(a z J h l ,F/33 /<9 License# Il yG( o 7 a
MECHANICAL COMPANY I o- v
SIGNATURE ZT . REGISTERED I Y/ N I FEE CUR ENT {� Y/N a
Address —I y �e✓t tF c� 2 i �) 3?Sy License# Ci\C O L 3 q� 6
OTHERL COMPANY
SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/N
Address I I License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3)sets of Building Plans;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
11111111 1111 IlIlIllIllIll
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000)
"* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be-due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health .Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem Wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to Inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
N YOUR
WARNING TO OWNER: YOUR FAILURE TO RECORPE Tlf T�F YOU INTE OF OMMENCEMENT END TO OBTAIN FIAY RESULT NANCING CIO CONSULT
PAYING TWICE FOR IMPROVEMENTS TO YOUR PRO
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S )
OWNER OR AGEN CONTRACTOR
Subscribe and swum to(or affirme efor meth'
Subscrib d and sworn to(or a rmed)b r m t is UU
� Who islare sonall to me or has/have produced
Who is/are to me or has/have produced as Identification.
as identification.
Notary Public
' )t Notary Public
Commission No.
Commission No.
ed Name of Noi t j.Print
* * MY e"1 ypg�
Name of d,grinCOMMISSIONDD 616391 MY COMMISSION#DD 616391
#
EXPIRES:November 20,2010 * * EXPIRES:November 20,2010
wrgT °P Bonded Thru Budget Notary Services �9'FOF F,��'°P Bonded Thru Budget Notary Services
FOF Fib
I 111111 11111 11111 11111 11111 11111 11111 11111 11111 11111 JIll Jill
NOTICE OF COMMENCEMENT 2009002859
State of Jôri'da County of 7CJt S CO
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with
Chapter 713,Florida Statutes,the following information iss provided in this Notice of Commencement:
1. Description of Property: Parcel No. _39?O l�J C C)3 H I I' L oc p Zeph y h;(1 j-
2`1-2(n- 2,-ooO- ooco- /%O Ma,ert•c. Cs haje ar p
Leal description of the property and street address it available) `1 ^�
PCB 5 PG5107 '/12 Co-tS I` •-f I(o l-rrt.t(7( 1,1(1 G /U
2. General Description of Improvement
Pcvk t cdd
3. Owner Information: Name JV H C F/ /15 L L. C
l099I L. (a.r►e/hacf- RS S 8- ?)O t -t--sdale A Z g52S)
Address City State
Interest in Property:
Rept.: 1220802 Ree: 10.00
Name of Fee Simple Titleholder: DS: 0.00 IT: 0.00
(It other than owner) 01/08/09 ----Dpty Clerk
Address , / C'y State
4. Contractor: Name ) (A4+€I�e/j
312tiZ A e�
/P n O e G.f F133 S2
Address city
5. Surety: Name
Address City State
Amount of Bond: :$ PRULR S. O'NEIL, PRSCO CLERK & COMPTROLLER
01/08/09
{ CM c—1 --IQ)
D 6. Lender: Name OR BK
tt11 Address City State
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served
0
m D O M as provided by Section 713.13(1)(a)(7);Florida Statutes:
=
r'O ZCjj Name
1fl Z C)C) 2— Address CRY
Xp O D C7 State
'7C 0-0"10
-n o-< -i C 8. In addition to himself,Owner designates
O of to receive a copy of the Lienor's
0 r - =O OC Notice as provided in Section 713.13(1)(b),Florida Statutes.
Z m .n
mCp N D=O 6m) -p 9. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date is
specified.
m v, -„rim - 0
Date Signature of Owner
STATE OF FLORIDA p
COUNTY OF
The foregoing instrument was acknowledged before me the _JQhl,tc>e 20ô 9 (date),by
7r 1' J4-'tom'✓'` DJ C/ (name of person acknowledging),who is a nally
known to or who has produced (type tification)a entificetio
Seal: �'1,( ' r
NOTARY
TONI SCHMIDT
dv1pc053048 * * MY COMMISSION#DD 616391
EXPIRES:November 20,2010
w��rFoF,oe`'°e Bonded Thru Budget Notary Services
1/ 6/2@9 17:12 813-783-3406 BEL AIRE
: ... .._......,..____.__.�,. ..._.,I..._. _—,_._-._. ...r «I., .r.wy., ._...,1.rwv.w - *
jv.v.
Ix : t :m :: : : : :
1y 4
I ,
: t
i I
' I
I f :
I i
r •
r.n iii ii
: ._ __.. _ ..... ............_. ......_..
I I �
fir, 4llG 4 �JrWJv.to wV
, .. ._..�.�,�.�,... � EL
�:�[..� alt __�3_1�.�_
._ -- JAL
I-
i^ _ _._ E N-0 CODES.i ' , asUJ
CO ATIQINA O Ir i � H, � „� r.r. fni ,
111111 $ UU* NUI■ *R
111111 iiaii wii
mUUU !! !I ! II : : --
IIIIII
• muuu
. i1IIiIIIiI1I z,
IUU
mililil
iluIH =
rInnI •
#a■#■aa#ia■a■
■■■ a■■##ia ■■
■ ® ■■ -' ■ ■ ■ iIRIRII$iiiI
• - I . k - - ■ 1 ■ I ■■■ilia ai/aa
s � aaiiiaiaiiaa■
■■■a■iiiia■#■
■■■■■■■#■■■#■
■ t ■If II ■ ! a■■a#aiiii■#a
#a■■■E■ ##■U■
#a■#■aaa##a■■
■■#i#aiiaa#i
■ I ■■ ■ It /A ■ ■■■#■■■ aa■■■
##■■■I•aaia■■#
- a■■i■aiaaa■a#
■■ail##■##■■■
• ■ fi ■fa IL II ■##iuia#ia■■a
iaia■ita##■la
• ■■■ai#aa■a■■
■■##■■■##■■■#
UI ■■ UI II ■■#a■##ai#■■■
' ■■■■ia#a#■■■■
• #a■iiia#a#■■■
aaia■a■a■a■a■
r u ■■ ■ i ■ I a■■■■i#a#aia
` �► ' tI
i■ia■alma■■■
'; i ■■ ii a ■ ■■■#■a####■a■
• - • I
#aia■aaiaa■a■
a##il#1#Uain
— ■fill#alai■■#
• ■ i ■■ - ■ u ■ ■ a##al##aa ■m*
ijili I
— ; j1
1ff j hI - a
U d II1 - - . U ii
iii
U '_ ti w
1111 i ill
1111 III I
d • 14
1<
o
i • I . I Ii iII 1'jig ii
IlIb
I fl Ø
______ 'C
• hi i• I I
E0
s I Q
f I
0 a!"!. CHEST BAY
�
4°
L g f
N � ;I L1 L— ! _`yam
h P
a M +aw�T.ni
C.s r fir`1 taro �i
nt
`ww Mi a= cl
wig cr b
/2 / n 15:+11'� des?6:t3fl t+ �r+yy rn`
State of Florida
DEPAWI M ' OF
HIGHWAY SAFETY AND MOTOR, VEHICLES
3A[.�AA,9f38Lr, FtrOA 3�
FKED 0 DZ 1?VSON,Itr
e.:ucucift DhecL*r
Msmh 20,2002
Mr.Bert A.•Moore,Fin uaiaL Mat agar
ufactwed Monaimg Fouudstion Systems
Oliver Tec ma1ogies,Iaoa~.
Post Office Box 4(467 SWSIL Avennc)
Hohenwald,Temcssee 38462
Deat Mx, Moore:
We wish to acknowledge receipt of your speeffledtiou and tea t rests yfmg that
your LongAtud5nel Stabilizing end Late aL Bt 1ng Sys ,1101 V. Used below complies with
the s i£tcartion and t1at ona set by the Depaztrne alt of Eshwatiy h ty and Motor Vehicles,
Rules 15C-1.0105, 15C-l.0107 and 1SC-1.0108,FbnWa n '$sra1ve Code.
InAullation instruoons must be available at the instails on site.
1101 V Longitudbal Stabilizing and Lat 1 Thing System
ZTO2"�• This systmn is for replacement of lofgitaxdi nal . This system can only be
rrsed-with sidswall anchor:pattr1ytg of s'4" Marlmron start angle 45 .
If you bave any questions,please advise at(407)623-1340.
Sincerely,
Phi B+errgelt,Proon Manager
Bm+esn of Mobile Home and
l eerrstional Vebinle Conntrucxj n
PRi :srb Dllvxsfan*fMotor Vth olcs
DcvtmQNS i EO1DA MGUW4x rns' L • DRtvsac LLCs •Mara*vE LOL •w,1D a
wail IOrkus i,BulldITflØjp.m.star du 3s399.O$OU
OUVER TECHNOLOGIES,INC. r'+'isivn C/tl',
FLORIDA INSTALLATION INSTRUCTIONS FOR THE
MODEL 11 1-V"aERIEIs AILSTSEL POLNb!TIA:'IYSISU
MODEL 11D1"V"(STEPS 1-15)
LONC1TWINAL ONLY:FOLLOW ST&$ 1-9
FOR ADD1NG LATERAL ARM:Follow$fcps 10-10
FOR CONCRSTI APP(JCA77ON5:Follow$raps 16-19
e,aweeRs srauo �_ 2.iou:IFas arAMP
1.SPECIAL CIRCUMSTANCES: If the following conditions occur-STOP! Contact Oliver Tbehnologr'es at 1-800-284.7437:
a)Pier height exceeds 48, b) Length of home exceeds 76'c)Root eaves exceed 1S"d)Sidewall height exceed 95"
9)Location is within 1500 feet of coast
INSTpJ..LATION OF GROUND PAN
2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan(C).
3. Place ground pan(C)directly below chassis I-beam . Press or drive pan firmly into soil until flush with or below soil.
SPECIAL NOTE:The longitudinal"V"brace system serves as a pier under the home end should be loaded as any
other pier. It Is recommended that after leveling piers,and one-third inch (1/3")before home is lowered completely on
to piers, complete steps 4 through 9 below then remove jacks,
INSTALLATION OF LONGIT IiMI AL"V"BRACE SYSTEM
NOTE: WHEN INSTALLING THE LONGITUDINAL SYaT1MQML A MINIMUM OF 2 SYSTEMS PIER FLOOR SECTION II REOUIRED.SOIL TEST
PROSE SHOULD BE USED TO DETERMINE CORRECT TYPE OF ANCHOR PER SOiL CLASSIFICATION.IF PROSE TEST READINGS ARE BETWEEN
173 3 275 A 3 FOOT ANCHOR RUSTIC USED,iF PROBE TEST READINGS ARE BETWEEN 2761350 A 4 FOOT ANCHOR MAY BE USED.USE
GROUND ANCHORS WiTH DIAGONAL TIES AND STABILIZER PLATES AVERY S'4".VERTICAL 711$ARE ALSO REQUIRED ON HOMES SUPPLIED
WITH VERTICAL TIE CONNECTION POINTS(PER FLORIDA RE( ).
4.Select the correct square tube brace(E)length for set•up(pier)height at support location, (The 18"tube Is always
used as the bottom part of the longitudinal arm). Note: tither tube can be used by itself,out anc drilled to length as long as a
40 to 45 degree angle is maintained.
PIER HEIGHT 1.25"ADJUSTABLE 1.50"ADJUSTABLE
(Approx.45 degrees Max.) Tubs Length Tube Length
7 314"to 25" 22" t3"
24 314"to 32 1/4' 32" 1$"
33'to 41
4t1"to a " g
5. Install (2)of the 1.50"square tubes(E (1a"tube,})into the"U"bracket(J),Insert carriage bolt and leave nut loose for flnai
adjustment.
6. Place I-beam connector(F)loosely on the bottom flange of the I-beam.
7 Slide the selected 1.25'tube(E)Into a 1,50"tube(E)and attach to i-beam connectors(F)and fasten loosely witsr bolt and nut.
8. Repeat steps 6 through 7 to create the"V"pattern cf the square tubes loosely In place.The angle Is not to exceed 45
degree and not below 40 degrees.
a.After all bolts are tightened,secure 1.25"and 1,50"tubes using four(4)114-14 x 3/4"self-tapping screws in pre drilled holes.
INSTALLATION Off_LATERAL TELESOfl4G,TRANSVERsE ARi1 SYSTEM
'ri&MODEL 1101 "V"(LONGITUDINAL&LATERAL.PROTECTION1 ELIMINATES THE NEED FOR MOST STABILIZER PLATES a FRAME TIES.
NQTCt THE USE OF TN 15 SYSTEM REQUIRES VERTICAL FOUR FOOT(4')GROUND ANCHOR MAY 51 USED EXCTIES
EXCEPT WHIRR THE HOME MANLIFACTURER SPECIFIES DIFFERENT,
10. Instal; remaining vertioal lie-down straps and 4'ground anchors per home manufacturer's Instructions.NOTE:Centerline
anchors to be sized according to soil torque condition.Any manufacturer's specifications for sidewall anchor loads in excess of
4,000 lbs. require_a 5'anchor per Florida Code.
11.NO'rE:Each system is required to have a frame tie and stabilizer attached at each lateral arm stabilizing location.This frame tie$
stabilizer plate needs to be located within 18"from of center ground pan.
12. Select the correct square tube brace(H)length for set-up lateral transverse at support location. The lengths come in either 60"
or 72"lengths. (With the '1.SL1"tube as the bottom tube,and the 1,25"tube as the inserted tube.)
13. install the 1.50 transverse brace(H)to the ground pan connector(O)with bait and nut.
14. Slide 1.25"transverse brace Into the 1.60"brace and attach to adjacent I-beam connector(I )with bolt and nu:.
Secure 1.S0"tr rtgyerss arm to 1.25"transverse arm usirc fc�f4)1/4"-14 x 3/4"seiI taaoine aorews in one-drilled holes,
OLIVER TECHNOLOGIES,INC. Telephone:931 79r,4655
1-ti00-284-7437 Fax:931.798-38i'
wwrvaoE�arttcshnologlc;.ayr-
1NffALLATlOlJ USING t" NCREiE RUMNER FOOTER an c
18. A cormrete runner.,footer or slab may be used in place of tna steel ground pan. n: n MY
a) The concrste chat)be minimum 2500 psi mix
h1 A concrete runner may be+Tither longitudinal or t•ansverse,and must be a min,mum of 8"deep with a rnintrrium width of 18 Ines
longitudinally or i ti inches transverse to allow proper distance between the concrete bc>�t and the edge of the concrete(see below)_
c) Footers must have ntinlmtrn surface area of 441 3q,In.(I.e.21"square),gid mutt he a minimum or S"deep.
d) if a full slab Is used,the depth must be a 4"minimum.
el Inspection of the system bracks:Installation is not reouir 1.. Doctors must a1i,3w for at IEeot 4 from teed corcrats exalt to the edge
of ine concrete.
NOTE:The bolitom of all footing a,pads,stabs God runners must be per loran juc1adtctron.
LONGITUDINAL,(Model 1101 LC"V")
17. W1usinç Parti1I.`101-W-S GA( simplyinstal the bracket in runnm' ter OR uVl"en tnsfelli►i Mc op
r� parr
_1(1-D :F A Cdr e1..The 1.101 (d►yset)CA bracket is attacnea to the concrete using(2)518x3"concrete wedge bolts(Simpson part 4
S162300H 5rr X 3"or Powers;equivalent).Pace the CA bracket in casired bcgtion. Mark bolt hole iocstbns,then us;ng a 518"dlemeto'
masonry oil,drill a hole to 3 minirn;rrtr depth of 3. Make out;all dust and c onotate;s t4d yn out of the holes.Paco Wedge bolts into drilled
holes,them pI ee 1101 (dry set)CA itracket onto wedge tart:=_and alert wedge bolt nUts. Takes hemmer and lightly drive the wedge bone
down by hitting the nut(making sure not to hit the i of threads on s bolt). me a!eeve'M cor►aet doe needA
of cot te t;nmplate by tightening nut`. to be a;or'+olovv iha ti�S2
LATERA.t:(Model 1101 TC"V")
'IS. For wet set(part* I101-N•TACA)insteitation simply install±1 a anchor boll into rusre/fo ter,For dry eel lnsta!latior,(part#1)91-D-TACA)
mark bolt hole locations,₹.*ten using a 5'8"disr_n-masonry bit,drill a hole to a rnirinrrun depth of 3'. Make sure al dust and concrete is
blown out of the hole.Piave wedge bolts(limpson part#81829004 518"X 3"or PPwers equivalent)into(D)concrete dry transverse
connector and into drilled hole.If needed,talus a hammer and lightly drive the+sedge bolts down by hitting the nut(making sure not to hit
toe top of threads on bcit),then remove the nut.The eve of concrete werioa molt n s to ere at qr helory tic+no e1.enr,exaf�
19.When using part#1101 CON(wetset)or 1101 t 1JD(dryad},utsreil per steps 17& 18.
Notes:
1. LENGTH OF HOUSE IS ''•HE ACTUAL BOX SIZE
2. + L2ERRATDAMEr'ATON (rwdsb
be)cxltin 18 artcr,fg�urld pan rra-r e)
3. K IJ- ATk"�N OF LCNv"'fl"t, : NALE3RAC ING ONLY
4, -r "VMSE&tfN GTU ►J _LOflONS
�fJiR MBER AND �,C CA tDN O1F' MODEL 19 t)1"W��. c
_____ -UP TO A 1 ROOF PlTCW
!" ALL WIDTHS;AND LENGTHS UP TO 52'
. 111.
lt •
LLiJI* __
ALL WIDTHS;AND LENGTHS OVER 52'TO 80'
- 1
140MES WITH 5112 ROOF PITCH REQUIRE,, PER FLORIDA REGULATIONS
6 systems -for home lengths up to 52' and 8 systems for homes ever 52'and up 30'. One stabilizer
plate and frame tie required at each ateraf bracing system.
n'or• a�taA'oved 4;soma ��` '
E1l4.hMS;11Av'.,9 fiU i -- ' I rrvi:.k,r.l:'l.•
!mmkona mopt w�0ri.! _! Sidi •r—�..
horre ridnuCWerm%padi- � P � •• 1 +w"S.••:k:RbY..a
fivi4h,t fo,sdewiU Stra A � -' \. '
are fr.As;els of 444 OIL "A T►mvom yen+,-nesn� I ;t'��''t• st;i*.�':l
T w."tocanons require a 5' ? conrao''r
a,�nor.Per Ronda Corte. .. • 2 H-Tenste is arm <
7' • • T p(1225')
� tc0.torr(1. C=OROUWND PAN
''• D=GROUND PAN CONNECTOR
( r,; id � ! �� f .ct F.. r• . U BR CKETS TR"WERS5
r'f D/a0B tN`Qarr
f '� bro�irse' � corr,soon E=TELESCOPING V SPACE
i I TUBE ASSETaLY WtW/1,5 ROT
, ran+q ,pra 1.prutx,i Ern `? TOM TUBE AND2.5 1. TUBE
✓' 7,,"
-✓ ' % v 9 s+:.a; INSERT
. r .r ! F='b' SPACE LBEAM CCNNEC• I
�, -" � ( TORS ASSEMBLY
l \-1 'rt / E V'9rsce 1 1� }�j i=T LESG =ft3 TRANSVERSE
{" �r T:p11..5') / f
4e.4am ar ,r /' a ARM ASSEMBLY
.. ` I=TRANS/ERE ARM)-BEAM
''==r ,_ F �� -ciroura Fay =NUECTC7R
( J-V PAN BRACKET
Model# 1101 "V"
J
LCnr�nude Ak4a11s:a rude for (i)a«As air am
iJ ry .Af/L+W('_r!�rlAhl Flat"ncreie bracket Hart# t1fl1 b-Cr�CA
4 .t�
Wet bracket part# ),
101 V!-CPCAnot Model 1101 CVO
9tipWn / cNriapr 6aa a Nut
REAM CONNEC1r)t4 BRA-^.KET Model 1101 (MW
not shown
stadde aoarvrx!r srourc ' _ [C=CONCRETE FOOTER/RUNNER
iancttn a mxy o!: !i l aI! r" .f' tr 1 1J CONCRETE U RRACKET TRANSVERSE
irBCaGorit sx�P!vrtl@dh)3ro'rta r'r ;•' '11 L:- T"--"
C t'AA�TIFCTOft GOnriBGts with a 5.1/x"x 2
t ramdactuv!s apaetM�aor» i' � i:r ..•.. � �d
Ifor* e'$$treae we In 'r % , ` 1/ "r*ftlape bet&nit)
x• t f : T3ni`ttrteatm?Eetsn i t; YT ' ?
t ncottdns raga.e e 5 ar,dirs, '' cornectrr t : ). l� E=T LESCOPINQ i BRACE
PnrR:[rdefads. r :; n`-Tam-mmeam �. ;UaE1,�^SI:+�18'_Y+NI1.5BOl-
' _ .-: .1 TOM TUBE AND 1.25 TUBE
rrr >c uOtkM{1.5' �.(yr
j �',;',%' `.. ( I==`+�" 9RAL`Ir)•BEAki GC)NNEC1\)R ASSEMBLY !
.�' •CQne .- �' 'C.Crsseci Mth de 5- 1f2'x 4' r1.age bait
r-:•V•nraar hoeam • L
- -,,u nrwAst i Connactor3 &nut)
j'" / `d;aas.aae /. /. !�.. 3 Y:=TELESCOP±NCB T SE :;
. xrrnocrors ' FtA.NSVER.+y A ih_
d•ccrcrsta i ASSEMBLY
v+ts a tot i'tZl,N VEPSEARM I-BEAM CONNECTOR
''``��•, i; , � � jommerds with grade 5.1/7 x 21f2" Can93ge t'd'.t
! �E- ^grace T i r J-'CONCRETE"V" BRACKET fcrmnwts• ith
}• �P tts�) / grade 6-1.1 x 4"cari age aok&tut)
Bann (1.5'! '+
.+ I o,•Et r rtynnrr
Model;Model # 1101 C "`J"
t)LtVER TECHNOLOGIES, INC. T•stephune: 7 •4555
1-B00.284.7437 Fax:931.7E 6.881.1
wwW,oUven rxlfei:on+