HomeMy WebLinkAbout08-8204 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 8204
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
oohs
Permit#:8204 Issued: 9/05/2008 Address: 6261 TIMBERLY LN B23#223
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: TOWNHOMES Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 157,985.00 Total Fees: 6,542.41 Subdivision: EILAND PARK TOWNHOMES
Amount Paid: 6,542.41 Date Paid: 9/05/2008 Parcel Number: 03-26-21-0230-00000-2230 III Name: LENNAR HOMES INC Name: US HOMES CORP- LENNAR
Addr: 600 N WESTSHORE BLVD. STE 900 Address: 6261 TIMBERLY LN -B23#223
TAMPA,FL. 33609 ZEPHYRHILLS, FL. 33542
Phone: Lic: Phone:
Work Desc: NEW TOWNHOME- SIESTA KEY 1663 SQ FT) LT#223 BLDG 23
PLUMBING FEE 98.10 SEWER CONNECTION RESIDEN1 2,010.00 ELECTRICAL FEE 147.15
WATER CONNECTION RESIDENT 641.00 MECHANICAL FEE 68.67 TRAFFIC IMPACT FEE 1% 25.07
TRAFFIC IMPACT FEE 99% 2,481.93 BUILDING FEE 727.08 RADON 16.63
WATER METER RES 3/4" 220.00 FIRE PLAN REVIEW FEES 93.28 FIRE INSPECTION FEES 13.50
aiicuiis°' k ".. µ ?�, iireruii ..
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your p rty. If you intend to obtain financing,consult with your lender or an attorney
before recording your c of commencement."
CONTRAC IGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
• • • • • • • • • ® •
PERFORMANCE BUSINESS PRODUCTS,INC.813.719-8008 FAX 813-719.7919
CITY OF ZEPHYRHILLS
ZEPHYRHILLS, FLORIDA
WATER ACCT. NO. DATE
OWNER/
RENTER ,.
MAILING 7 n !`g` t//tL �E' 1/ ()
iLtIp4 33c
SERVICE ADDRESS 2 { ! Lt H'2z
SHUT OFF SERVICE ❑ WATER
TURN ON SERVICE ❑ SEWER
INSTALL METER ❑ GARBAGE
READ METER ❑ IN CITY
CHECK METER ❑ ❑ OUT CITY
OTHER ❑ -�----No.OF UNITS
pQ DEPOSIT AMOUNT
3/ _____AMOUNT LAST BILL
'O LM,4 * V 2L� DATE
P lJ_'
MISC.CHARGE
METER: full
irrigation
WORK COMPLETED BY ORDER TAKEN BY
&DATE COMPLETED
OR I B
Retain white form in office at all times.
Send pink&yellow forms to Water Service Dept.
Water Service Dept.to sign yellow form&return to office.
PASCO COUNTY, FLORIDA
Permit No. 26
Date Permitted
Builder Name/Owner Name L f ACL r /-h v E Control#
County Parcel No. y 3-21- -2-/-023 -COO O()'Z24ubDiv:
Address/Location / 24 I L71 Jasa. LH ZZ5
Classification/Type of Use k ,2 i't-r ct1 Q7ujckdY► 'z_
TRANSPORTATION IMPACT FEE Rate: C S Sq Ft Unit: /(Q(aJ'
Exempt ❑ Yes ❑ No How Determined
Impact Fee Amount $ 215o7. Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt a Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ - �
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
6261 TIMBERLY LANE LT#223 BLDG 23 SIESTA KEY MODEL-
LENNAR HOMES PRMT#8204
SQ.FEET PRICE
MAIN OR LIVING: 1,663 $ 95.00
OTHER AREA UNDER ROOF: - $ 94.00
OTHER: - $ -
VALUATION $ 157,985.00
FEE SHEET $ 654.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 727.08
ELECTRICAL: $ 147.15
PLUMBING: $ 98.10
MECHANICAL: $ 68.67
SUB-TOTAL $ 1,041.00
RADON: $ 16.63
TOTAL $ 1,057.63
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $
TOTAL: $ 2,651.00
WATER METER: $ 220.00 3/4 METER
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 93.28
INSPECTION TOTAL: $ 13.50
PERMIT TOTAL
TOTAL: $ 106.78
PUBLIC SAFETY IMPACT FEES
POLICE PREVIOUSLY PD
FIRE PREVIOUSLY PD
5% $ - PREVIOUSLY PD
TOTAL: $ - N/A
SUB-TOTAL $ 4,035.41
PARK IMPACT FEES I PREVIOUSLY PD
SIF'S: PREVIOUSLY PD
100.0% PREVIOUSLY PD May pay 25%of tif and balance 75%due b4 pre-meter
1.0%_$ - PREVIOUSLY PD 25%-due$626.75- 75%due before pre-meter-$1,880.25
TOTAL:_$ -- N/A permit cost wl 25%tif$4,662.16"""'
T I F'S: $ 2,507.00 Minus Credit-from previously paid Tif-Tif increase
99%_$ 2,481.93 Minus Credit-from previously paid Tif-Tif increase
1%_$ 25.07 Minus Credit-from previously paid Tif-Tif increase
TOTAL: $ 6,542.41
IIIII 111111110 11111 111111111 IIII
2008129021
CIo_,, ry F t ' O Rcpt: 1201265 Rec: 10.00
t�I ;\ a ';,FY THAT THE FOREGOING IS A DS: 0.00 I T 0.00+n, d? r, ! L OPY OF 7HE D0CUME ON FILE 09/04/08 Dpty Clerk
r �I r<<,OPD IN THIS OFFICE W NESS M
D JE PI0TMAN PASCO COUNTY CLERK
�� 7 � FI IALSE
09/04/08 10:55am 1 of
OR BK 7918 PG 878
NOTICE OF COMMENCEMENT
Permit No.
Property Identification No. Q3-.21.-.Q/- O.30-c9O 0o O-223O
THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property,and in accordance with
Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT..
1.Description of property(legal description;) Lo T gro /Qv�c�G l' _ INoMES poi Gc� P+ 44-0
a)Street Address: 6.'1(./ T/mEF2 c.y LANE
2.General description of improvements: aiNo4,E FPMr�y e_tioewcr. /Poor. /seIer®J E.yeces ,a
3.Owner Information
a)Name and address: LewNAR #o,1{ ,ZN 4 O0 /V. a1Esr.Wo,E BL✓D ,7 56o'1
b)Name and address of fee simple titleholder(if other than owner)
• c)Interest in property
• 4.Contractor Information
a)Name and address: .STEVE,S'rr,ii/, — (.00 Al. LJe5TSNo2E L3wv.S rE 600 79Mfl41 4 33bo9
b)Telephone No.: .(813) 79—i2?? Fax No.(Opt.)
5.Surety Information
a)Name and address: N/A
b)Amount of Bond: W/4
c)Telephone No.: Fax No.(Opt.)
6.Lender
a)Name and address: i1f�A
Phone No.
7.Identity of person within the State of Florida designated by owner upon whom notices or other documents may bo served:
a)Name and address:.S>EVE.SMI rq (, N AIZ.ErJNo,2f &vo, .SrE boo, T.cMprV F4 33:bo9
b)Telephone No.: (813') 76 9—32?-7 Fax No. (Opt.)
• 8.In addition to.himself,owner designates the following person to receive a copy of the Lienor's Notice.as provided In Section
713.13(1)(b),Florida Statutes:
a)Name and address: N�q
b)Telephone No.: Fax No. (Opt,)
9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a.dI ferent date is
specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATIONOF TI%E NOT-ICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS.UNDER CHAPTER 713,PARS ,SIGN 713:13,
FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YO Q ERTY.
A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE RErQR W ITJRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN AT,Tth EY B+'P0RE.
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PASCO
Signature o . Owner's Authorize icer/Directar/ParinerfManager
ste. c-re, NS
Print Name
The foregoing instrument was acknowledged before me this Mfm day of ✓u -'1 ,20 09•,by__ _____,'. k•
S?FpRNS • as MANAGE/L (type of au ority,e.g of€icer,trustee,attorney
in fact)for LEwn/RR e o if_"oR4.7/a AJ (name of party on behalf of whom inifnent was executed).
Personally Known ✓ OR Produced Identification Notary Signature
Type of Identification Produced. Name(print) s /VNo 4.�Er9r•1'
Verification pursuant to Section 92.525,Florida Statutes.Under penalties of.perjury,I declare that I have read the foregoing and that
the facts stated in it are true to the best of my knowledge and belief.
" sit EUSSA M.HOLLERAN Si ure o erson.Signing Above
FORMS! OC,rvad2oo7 F Commission DD 774023
• - Expires June 6,2012
BadadThuTroYF�nMwmuKeeoo-a7c�o
bid-��U-UUZU llILy UI LG)JIIYI1IIIIJI i oT'
Building Department
Q 9i8 - as39
Date Received Phone Contact for Permitting 8
��NNfIiQ ri�� S Owner Phone Number r!8/3)?69 'Sz7
Owner's Name ,'
Owner's Address (/ /V�DO • G,/ SfSfFOIZE 5Lfr Owner Phone Number
Owner Phone Number
Fee Simple Titleholder Name
Fee Simple Titleholder Address
(„gnif ZFI'Ny/RN�!-[S F - 3351/0 LOT# 2 '?S
JOB ADDRESS (oa�D I ��M 3 E v
re/ No �/T n .j�L II PARCEL ID# -2/-O23 0 0000 — o?13a
SUBDIVISION (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED n NEW CONSTR ADD/ALT O SIGN MOVE DEMOLISH
INSTALL e REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME /V STEEL OTHER
Al cw Ca1vST1e.UCT ON — -7`-oUJ jgL7 �S
DESCRIPTION OF WORK 2
BUILDING SIZE
SQFOOTAGE 153I HEIGHT a.STD�
BUILDING $ 3 i 6 S- J VALUATION OF TOTAL CONSTRUCTION
�1 AMP SERVICE PROGRESS ENERGY W.R.E.C.
ELECTRICAL $ � � 10
PLUMBING $ P
MECHANICAL VALUATION OF MECHANICAL INSTALLATION
GAS Q ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES =NO
jiiuhhht llllltitlllliillllll ,,lhlhhlhhuhuhihT 11l11i i,ilillIIlIII 111111 IlulIIIiiIlIIlliii Till! 1111111 11111 iii TTTTII,
BUILDER COMPANY LgN/VA�e /{O.✓� S
SIGNATURE REGISTERED Y/ Nj FEE CURRENT Y/N
Address N JEa 8.&v ' 7 A j - 3o9] License# C 13G/ a
ELECTRICIAN COMPANY /f01QGA/�/ G EG fie/L # , GLr!
SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N
Address ,f E• O OEYt Sr Li *t-,gKo /'L 3308/ I License# FC/3 ooa S(a
PLUMBER COMPANY =AWI-A�Q�J�K //GEn?9k0 fl /#V-
SIGNATURE REGISTERED Y/ N J FEE CURRENT Y/N
Address /y92 4' R/2S'J SAM i4 .CL 33 /3j License# CFG D'// 72
MECHANICAL COMPANY 8 erfr' .,8f G
SIGNATURE REGISTERED Y NN FEE CURRENT Y/N
Address . 'O. Bo)( 5Og & . oNfT?oiNr L ' '6?V1 CAC o5$ a 2
OTHER COMPANY C% 1TL/it1(,- /Q Fi,UG _Ty .
SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N
Address q U $//O4 L/uF&v, sP4,NfL,, 3IO7l License# 'CT 799 9 /
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms; R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed,
Sanitary Facilities& 1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms,R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans W/Silt Fence Installed,
Sanitary Facilities&1 dumpster,Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500, a Notice of Commencement Is required. (A/C upgrades over$5000)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state.law. If the owner or Intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done In compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and Installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I Understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions i must take to be in compliance. Such agencies Include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps ofEngineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan Is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. (,understand that a sparate permit may be required for electrical work;
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the applie work and not as authorIty to,violate1 cation. A
er, or
permit issued shall be const a echnical codes, nor shall Issuancd to be a license to proceed withe of a permit prevent the Building Official from thereafter
setset aside any provisions of h
in plans, construction or violations of any codes. Every permit Issuore dauthorized by
shall become
invalid
requiring a correction of errors d by such permit is commenced within six months of permit issuance,
the permit is suspended or abando the BuiIdPeriod of six Official for0)a period not to exceedtninetyr(90) days and will demonstrate
tension
may be requested, in writing, from 9
the�ob is considered abandoned
.
justifiable cause for the exension. If work ceases for ninety(90) consecutive days,
WARNIN G TO OWNER: YOU FAILURE TO RECORD A NOTICE OF COMM TNOC ENT F NANC NG C'ONSULT
PAYING TWICE FOR IMPROV TO YOUR PROPERTY. IF YOU INTEND NCE ENT.
WITH YOUR LENDER 0 O Y BEFORE RECORDING YOUR NO iCE.
FLORIDA JURAT(F:S. 117.
CONTRACTOR
OWNER OR AGENT e this T✓may Subscribed and sworn to r formed) me this T✓ty
Subscribed and sworn to( rme 8 TH by !
r _by ,To Ety
1Nho are personally known to as/have produce
d
who ss are personally known to me or as/have produced as identification.
as Identification.
Notary Public
Notary Public
D-7•-74 p2 Commission No.
1 L O 23
Commission No.
Na f No ary typed, printed or st
Nam o ary typed, „ A M.H0LLERAN '! ELISSA M.H0LLERAN
DD 774023 :"; Commission 00 774023
Commission _
Commiss i~_
Expires June 6,2012 �`= Expires June 6,2012
r iN
Bonded Thru Tray Fein Msuranca 900 a�'•f019 .Qs�! Bonded T,u Troy Fain h uranua BQQ4BFM1
City.of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received:Site: 22 (O I ( - I y
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kal ' Switzer ans Examiner ate Contractor and/or Homeowner
(Required when comments are present)
FORM 600A-2004R EnergyGaugeV 4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION'
Florida.Department of Community Affairs
Residential Whole Building Performance Method A
rProjectName: LHI531SK-SIESTA KEY 1531 S.F.LIVING AREABuilder - LENNAR HOMES fit.��-
Address: Permitting Office: C. D•} Ze 1" r
City,state: Permit Number: g z"-,
Owner. Jurisdiction Number: , U Cii
Climate Zone: Central -
1. Now construction or existing New —T12. Cooling systems
2. Single family or multi-family Multi-family — a.Central Unit Cap:28.2 kBtw'hr
3. Number of units,if multi-family I — SEER:14.00
4. Number of Bedrooms 2 — b.N/A
5. Is this a worst case? Yes —
6. Conditionerl floor area(ft=) 1531 ft= — c.N/A —
7. Glass type!and aura:(Label mqd.by 13.104.43 if not default) —
i a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(3ngle Default)153.0111 _ a. Electric Heat Pump - Cap:28.2 kBtwbr _
b.SHGC: HSPF:8.20 —
(or Clear or Tint DEFAULT) 7b. (Clear)153.0 ft' b.N/A —
8. Floortypes —
a. Slab-On-Grade Edge Insulation R-0.0,36.0(p)ft c.N/A 7
b.Raised Wood,Post or Pier R=i 1.0,124.Oft2 — -
c. N/A — 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons —
a.Concrete.Int insul,Exterior R=4.1.390.0 ft= _ EF:0.92
b.N/A _ b.N/A
c.N/A
d,N/A — c.Conservation credits
c.N/A _ (UR Heat recovery,Solar
10. Ceiling types — DHP-Dedicated heat pump)
a. Under Attic R-'30.0,87&O ft2 15. HVAC credits
b.N/A (CF-Ceiling fan,CV-Cross ventilation,
c. N/A HF-Whole house fan,
11. Ducts — PT-Programmable Tbetmostet,
a. Sup:Unc. Ref:Con. AH(Scalcd):intcrior Sup.R'6.0,150.0 ft MZ-C-Multizone cooling,
b.N/A -, )A7,-H-MultIzone heating)
Total as-built points: 14498
t31af3s/FloorArea: 0.10 Total base points: 16492 PA
I hereby certify that the plans and specifications covered by I Review of the plans and
this calculation are in co lance with the Florida Ene specifications covered by this
Code. calculation Indicates compliance
PREPARED BY; Florida Energy Code.
DATE: ''l-a� ?�GfD ��ae constnktion is completed this building will be inspected for >
II hereby certify that this building sign d,i in compliance compliance with Section 553.906
with the Florida Energy Code. Florida Statutes. cob wo
OWNER/AGENT: BUILDING OFFICIAL:
DATE' - — DATE• .. -- —
1 Predominant glass type.For s type and areas,see Summer&Winter Glass output on pages 2&4.
EnergyGauge®(Version:FLRCSB v4.5.2)
FORM 600A-2004R EnergyGaugeV 4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION'
Florida.Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: LH1531SK.SIESTA KY-1531 S.F.LIVING ARE.Builder: LENNAR HOMES
Address: Permitting Office:
City,State: , Permit Number:
Owner: Jurisdiction Number.
Climate Zone_ Central _^- _... . __�
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-fancily Multi-family — a. Central Unit Cap:28.2 kBtu/hr _
3. Number of units,if multi-family I — SEER:14.00
4. Number of Bedrooms 2 — b.N/A
5. Is this a worst case? Yes —
6. Conditioned floor area(ft=) 1531 ft — L.N/A —
7. Glass type]and arcs:(label regd.by 13-104.4.5 if not default) —
i a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default)153,0 R' — a. 1:leasic Heat Pump Cap:28.2 kBtv/tu _,
b.SfiliC:
HSPF:8.20
(or Clear or Tint DEFAULT) 7b. (Clear)153.0 1t' b.N/A
8. Floor types —
a. Slab-On-Grads Edge Insulation R'^0.0,36.0(p)ft _ C.N/A
b.Raised Wood,PoSt or Pier R=11.0,124.oft' —
c. N/A — 14. Hot water systems
a. Electric Resistance Cap:40.0 gallons
9. Wall types —
a. Concrete,Int insul,Exterior R=4.1.390.0 ft= — EF:0.92 _
b.N/A — b.N/A —
c.N/A
d.N/A — e.Conservation credits
o.N/A — (HR-Heat tray,Solar
10. Ceiling types — DHP-Dedicated beat pump)
a. Under Attic R=30.0,878.0 ft' 15. HVAC credits —
b.N/A (CF-Ceiling fan,CV-Cross ventilation,
c. N/A HP-Whole house fan,
11. Ducts _ PT-Programmable Theonostet.
a. Sup:Una Ret:Con. AH(Scalcd):1ninior Sup.R=6.0,150.0 Ft MZ-C-Multizone cooling,
b.N/A M7,-H-Multizone heating)
I_.. __ - . •-�-.—Total as-built points: 14498 - _�.• •. '
Glass/Floor Area: 0.10 Total base points: 16492 PAS S
cI hereby certify that the plans and specfications covered by Review of the plans and
is calculation are in co lance with the Florida Eno specifications covered by this o� s
Code. calculation Indicates compliance
PREPARED BY: Z", a Florida Energy Code.
�.�� �� Before construction is completed
DATE: this building will be inspected for
l I hereby certify that this building,as designed,is in compliance eompriance with Section 553.908
with the Florida Energy Code. Florida Statutes. �coD W►%
___
OWNERIAGENT: BUILDING OFFICIAL:_
DATE: DATE:
1 Predominant glass type.For actual glass type and areas,sea Summer&Winter Glass output on pages 2&4.
Energyeauge®(Version:FLRCSB v4.5.2)
FORM 600A-2Q04R EnergyGauge®4.5.2
SUMMER CALCULATIONS '
Residential Whole Building Performance Method A - Details
ADDRESS:,,, PERMIT#:
BASE AS-BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC pmt Len Hgt Area X SPM X SOF=Points. ;
.16 1531.0 24,35 6710.0 1,Single,Clear W 1.3 6.0 32.0 57.68 0.94 17E7:
2.Single,Clear E 5.0 6.0 32.0 63.97 0.57 1170.
3.Single,Clear E 2.0 6.0 16.0 63.97 0.86 877.
4,$ingle,Clear W 6.0 4.0 7.0 57.68 0.46 187.0 t ,
5.Single,Clear W 8.0 6.0 34.0 57.68 0.62 1206.0
6,Single,Clear E 1.3 6.0 16.0 63.97 0.94 958.0 ':
7.Single.Clear E 1.3 10.5 16.0 63.97 0.99 10.10.0
1 '
As-Bullt Total: 153.0 7141 .:,'.,
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Point*:
Adjacent 0.0 0.00 0.0 1.Concrete,lnt Insul,Exterior 4.1 390.0 1.18 460.2
Exterior 390.0 1.90 741.0
Have Total: 390.0 741.0 As-Built Total: 390.0
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points'.. ;
Apjacent 0.0 0.00 0.0 1,Exterior Insulated 20.0 4.80 96.0
Exterior 20.0 4.80 96.0 ,
Base Total: 20.0 V 96.0 As-Built Total: 20,0
CEILING TYPES Area X BSPM = Points, Type R Value Area X SPM X SCM
Under Attie 878.0 2.13 1870.1 1.Under Attic 30.0 978.0 2.13X 1.00 1870,]
Base Total: 878.0. 1670.1- As-Buit Total: . .576A 1670A s '
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = PoiMs;�
Stab 36.0(p) -31.8 -1144.8 1.Slab-On-Grade Edge Insulation 0.0 36.0(p) -31.90 V X1146.4
Raised 124.0 -3,43 -425.3 2.Raised Wood,Post or Pier 11.0 124.0 1.63 22B.3 ,
Base Total: -1570.1 As-Built Total: •160.0 -9
INFILTRATION Area X BSPM = Points Area X SPM = Point '
1531.0 14.31 21908.6 1531.0 14.31 21908.6
EnergyGauge®DGA Form 600A-2004R EnergyOaugs�IFlaRES'2004R FLRCSB v4.5.2
FORM 600A-20048 tnsrgyvawgew w.o
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details :a
#:
ADDRESS: ,, , PERMIT •
BASE AS-BUILT
Summer Base Points: 29755.6 Summer As-Built Points; 30559.9 '
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling • .
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AHU)
(sys I•central Unit 2a200DIuh,SEER/EFF(44.0)DuCts.Unc(S},COn(R),Int(AH),R6.0(INS)
30660 1.00 (1.08 x 1.150 x 0.85) 0.244 1.000 7897.0
29755.6 0.3250 9670.6 30559.9 1.00 1.061 0.244 1.000 7891.0 -
r j
EnergyGauga DCA Form 600A-20048 EnergyGaugea/FIaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4,5.2
WINTER CALCULATIONS '
Residential Whole Building Performance Method A - Details
[ADDRESS: ,,, PERMIT#:
BASE AS-BUILT ; ,. S. ;
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF=Po!
18 1531.0 9.11 2511.0 1.Single,Clear W 1.3 6.0 32.0 13.25 1.01 427b ;,.
2.Single,Clear E 5.0 5.0 32.0 12.37 1.13 447:0
3.Single,Clear E 2.0 6.0 16.0 12.37 1.03 203.0
4.Single,Clear W 8.0 4.0 7.0 13.25 1.10 102.0.
5,Single,Clear W 6.0 8.0 34.0 13.25 1.07 481.0
6,Single,Clear E 1.3 6.0 16.0 12.37 1.01 200.0.
7.Single,Clear E 1.3 10.5 16.0 12.37 1.00 198,0`
As-Built Total: 163.0 2052.0 ,�
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = PoIr ts;...%
Adjacent 0.0 0.00 0,0 1,Concrete,Int Insul,Exterior 4.1 390.0 3.31 12288:0 ..
Exterior 390.0 2.00 790.0
Base Total: 390.0 780.0 As-Built Total: 390.0 136
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points'-z, •'
Adjacent 0,0 0.00 0.0 1.Exterior Insulated 20.0 5.10 102,
Exterior 20.0 5.10 102.0
Base Total: 20.0 102.0 As-Built Total: 20.0 702.0 r
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM= Points•, •'
Under Attic 876.0 0.64 561.9 1.Under Attic 30.0 879.0 0.64 X 1.00 581.6
Base Total• 876.0 561,9 As-Built Total:. • 879.0 561.9
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points:. •
Slab 36.0(p) -1.9 -68.4 1.Slab-On-Grade Edge Insulation 0.0 36.0(p) 2.50 90.0
Raised 124.0 •0.20 -24.8 2.Raised.Wood,Post or Pier 11.0 124.0 0.47 58.$
Base Total: -93.2 As-BulltTotal: 160.0 14Lt
INFILTRATION Area X BWPM = Points Area X WPM = Points
1531.0 -028 -428.7 1531.0 • -O.zB -428.7
F_nergyGaugea OCA Form 600A-2004R EnergyGeuge8WFIaREB'2004R FLRCSB v4.5.2
FORM 60OA-2004R cnergy�augew 4.a.�
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , ,
PERMIT#:
BASE AS-BUILT
Winter Base Points; 3433.0 Winter As-Built Points; 3730.6
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AMU)
(sys 1:Electric Heat Pump 28200 btuh,EFF(B2)Duot6:U+rc(S),Con(R),tnt(AH),R6.0
3730.6 1.000 (1.066 x 1.160 x 0.87)0.416 1.000 1681.3
3433.0 0.5540 1901.9 3730.6 1.00 1.083 0.416 1.000 1681.3
EneryyGaugen DCA Form 600A-2004R EnergyG8Uge®/F1aRES'2004R FLRCSB V4.5.2
FORM 600A-?004R tnergyuauge 4.O.•c
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
PERMIT#:
DDRESS: , , ,
BASE AS-BUILT . .•
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 49200 -
As-BugtTotal: 492O:0.
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water Total ~�
Points Points Points Points Points Points Points Points
9671 1902 4920 16492 7897 1681 4920 14498•'
PASS
* d
Cab wo
EnergyGauga DCA Form 600A-2004R EnergyGauge�VFiaRES'2004R FLRCSB v4.5.2
I-VKM (tUUA-1UU4K hnergyGsuge�)4.5.2 .
Code Compliance Checklist
Residential Whole Building Performance Method A - 'Details
[ADDRESS:,,, PERMIT#:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST ,•
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE _—_•T •_ —_—__ CHECK
Exterior Windows&Doors 608.1.ASC.1.1 Maxlmu3�fm/sg.R w{{199V area;.5¢fn1/9Ct. poor area, — —_
Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk.gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall;
foundation&wan sole or sill plate;joints between exterior wall panels at corners;utility
penetrations;between wall panels&top/bottom plates;between walls and floor.
{ EXCEPTION:Frame walls where a continuous Infiltration barrier is installed that extends
from,and is sealed to the foundation to the top plate_.._.,_
Floors 606.1.ABC.1.2.2 Penetratlons/openings>1/8"sealed unless backed by truss or joint members.
EXCEPTION;Frame floors where a continuous infiltration barrier Is installed that is sealed
• to theyerimeter1 penetrations,and seams; • . ......
Ceilings 606.1.ABC,1.2.3 Between walls&ceilings:penetrations of calling plane of top floor,around shafts,chases,
soffits.chimneys,cabinets sealed to continuous air barrier,gaps in gyp board&top plate;
attic access.EXCEPTION:Frame ceilings where a continuous Infiltration barrier Is
installed that is sealed at the perimeter,at penetratjons Bna seams,
Recessed Lighting Fixtures 606,1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,Installed Inside a
sealed box with 1 r2-clearance&3"from insulation:or Type IC rated with<2-0 cfm from
conditioned s ace tested. __-- --._.... . ..
Mukl std Houses.. 508.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.•
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion alt.
6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.)
MPONENTS __ ._. _ .SECTION__ .._. .. R�FQU_It?,EMETNT$
Water Heaters 612.1 [Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked air
_ — _ _ _ breaker_(glegtrio)or cutoff(gas)must be prgvidg�.External or built M heat trac re fired.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
— efficiency 01 78%. - ----_-_..— _ ...... ... . ....
Shower heads 612.1 Water flow must bejçJcted to qo more than 2.6 ciallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and Installed in accordance with the criteria of Section 610.
Ducts in unconditioned allies:R-6 min.Insulation..
HVAQ Controls 607.1 or automatic thermostat for each system
insulation (604.1,602.1 Callings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling&floors R-11.
EnergyGaugem DCA Form 60OA-2004R EnorgyGauge4 'FtaRES'2004R FLRCSB v4.52
•h
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CA.RI)
ESTIMATED ENERGY PERFORMANCE SCORE*=88.2
The higher the score,the more efficient the home.
1. New construction or existing New — 12. Cooling systems
Z Single family or multi-family Multi-family — a. Central Unit Cap:28.2 kBnt/hr
3. Number of units,if multi-family I — SEER:14.00
4. Number of Bedrooms 2 b.N/A _
S. Is this a worst case? Yes _ _
6. Conditioned floor area(ft2) 1531 ft2 _ c.N/A _
7. Glass type1 and area:(Label rcqd.by 13-104.4.5 if not default)
a, U-factor: Description Area 13. Heating syeteme
(or Single or Double i)LFAULT) 7a(Snglc Default)153.0 f _ a.Electric Heat Pump Cap:282 kBtu/hr —
b.SHGC: HSPF:8.20 —
(or Clear or Tint DEFAULT) 7b. (Clear)153.0 R° _ b.N/A —
8. Floor types
a_ Slab-On-Grade Edge Insulation R 0.0,36.0(p)ft _ c.NIA _.
B.Raised Wood,Post or Pier R='11.01 124,0ft2 —
c. N/A ,_, 14. Hot water systems
9. Wall types a.Ploetrie Re3istance Cap:40.0 gallons
a. Concrete,Int Insul,Exterior R4.I,390.0 ft _ EF:0.92
b.N/A — b.N/A
c.N/A
d.N/A _ c. Conservation credits _
e.N/A _ (HR-Heat recovery,Solar
10. Ceiling typos DHP-Dodicetcd heat pump)
a. Under Attic R=30.0,878.0 ft2 15. HVAC credits
b.N/A _ (CF-Ceiling fan,CV-Cross ventilation,
c. N/A _ I•IF-Whole house fan,
11, Ducts ('T-Programmable Thermostat,
a. Sup:Une. Rat:Con. AH(Sealed):Interior Sup.R"6.0,150.0 ft _ M7-C-Multi one cooling,
b.N/A _ MZ.H-Muldzone heating)
I certify that this home has complied ith the Florida Energy Efficiency Code For Building
Construction through the above en sa " which will be installed(or exceeded) � p
in this home before final inspecti a EPL Display Card will be completed
based on installed Code co
Builder Signature: Date: ,
*
Address of New Home: City/FL Zip: b y,�
"'NOTE: The home's estimated energy performance score is only available through the FLA/R.ES computer program
This Is not a Building Energy Rating,1/your score is 80 or greater(or 86 for a US EPA/DOE EnergyStarr"designation),
your home may qualms for energy efficiency mortgage(EEM)incentives((you obtain a Florida Energy Gauge Rating,
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsea.ucfedu for
informarion and a list of certified Raters.For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Afairs at 850/487-1824.
1 Predominant glass type.For actual glass type and areas,sso Summer&Winter Qlass output on pages 2&4.
EnergyGauge®(Version:FIJRCSB v4.5.2)
Job: SIESTA KEY-1631 S.F....
4wrightsott" Load Short Form Date: 11112/2007
vtcu Entire House a y: TRH
SIMPSON MECHANICAL
For: LENNAR HOMES
De • • : ',
Htg Cig Infiltration
Outside db(°F) 40 92 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD(°F) 30 17 Fireplaces 0
Daily range - L
inside humidity(%) 50 50
Moisture difference(grAb) 26 52
HEATING EQUIPMENT COOLING EQUIPMENT
Make Lennox Make Lennox
Trade I4HPX Series Trade 14HPX Series
Model 14HPX-030-230` Cond 14HPX-030.230'
Coil CBX26UH-030'
Efficiency 8.2 HSPF Efficiency 14 EER
Heating input Sensible cooling 22276 Btuh
Heating output 28200 Btuh t 47°F Latent cooling 5922 Btuh
Temperature rise 26 °F Total cooling 28200_ Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfrn
Air flow factor 0.051 cfm/Btuh Air flow factor 0.055 cfmBtuh
Static pressure 0.00 in H2O Static pressure 0.00 in H2O
Space thermostat 2 STAGE HEA Load sensible heat ratio 0.82
ROOM NAME Area Htg load Cig load Ht AVF CI AVF
(ft') (Btuh) (Btuh) (cfm)• (cfm)
LIVING 290 6473 5341 .327 292
• STAIRS/POWDER 109 798 109 40 6
DINING 196 1315 0 66 0
• KITCHEN-NOOK 145 4356 3412 220 187
HALL 67 75 99 4 5
MASTER BATH so 90 119 5 7
MASTER B.R. 203 2913 4580 147 250
• BATH#2 123 139 184 7 10
DEN 152 171 466 ' 9 25
B.R.#2 167 3469 3981 175 218
9ohtft is Values haye been mMWJIY OVetridden
Printout certified by ACCA to meet all requirements of Manual J 6th Ed.
i..
. vv,,ght c ft RI bsuge Realdenllal 6.0.107 RSR2901e 20O6-M20 Q9'.3011
ZATamniy HVACW115518KJ8.rrp C&a-MJ6 OAentatien-W Page 1
Entire House 1531 19797 18291 1000 1000
Other equip loads 1293 750
Equip.Gp, 0.97 RSM 18546
Latent cooling 4243
TOTALS 1531 21090 22789 1000 1000
Bold/mile vilUM Mve been manuefy OYOMaMen
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
WYIghtsc RVyM 9uhe Re kl,nliel6.0.10?R8R29019 20D8.MbY-20093011
l'Tommy HVA01W183iSKJe.np Cale-MJ8 Olwwbttan s W Pay 2