Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
08-8212
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8212 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL Permit#:8212 Issued: 9/05/2008 Address: 37549 DALIHA TERR LT 185 BLD19 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: TOWNHOMES Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 157,985.00 Total Fees: 8,236.73 Subdivision: EILAND PARK TOWNHOMES Amount Paid: 8,236.73 Date Paid: 9/05/2008 Parcel Number: 03-26-21-0230-00000-1850 Name: LENNAR HOMES INC Name: LENNAR HOMES INC. Addr: 600 N WESTSHORE BLVD. STE 900 Address: 600 N. WESTSHORE BLVD TAMPA,FL. 33609 TAMPA, FL 33609 Phone: Lic: Phone: (813)769-5277 Work Desc: NEW TOWNHOME - MARTINIQUE 1663 SQ FT LT 185 BLDG 19 BUILDING FEE 727.08 ELECTRICAL FEE 147.15 PLUMBING FEE 98.10 MECHANICAL FEE 68.67 RADON 16.63 SEWER CONNECTION RESIDENT 2,010.00 WATER CONNECTION RESIDENT 641.00 WATER METER RES 3/4" 220.00 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sfr/100% 1,740.00 SCHOOL IMPACT FEE-sfr/1% 17.40 TRAFFIC IMPACT FEE 99% 1,109.80 TRAFFIC IMPACT FEE 1% 11.21 FIRE PLAN REVIEW FEES 93.28 FIRE INSPECTION FEES 13.50 8 jfyV Cam- �D� :: FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your props If you intend to obtain financing,consult with your lender or an attorney before recording your notic f mmencement." CONTRACTORS SI TURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. f L/Z (' Date Permitted Builder Name/Owner Name [eAr- 3 -- YVt€. Control# County Parcel No, D3-2fo-2( 023y -000 -ISubDiv: Address/Location 3'7S4Q c It►'lam e 9 Ltr 1 05 Classification/Type of Use t Out/\ TRANSPORTATION IMPACT FEE Rate: 5 Sq Ft Unit: /6Q Exempt ❑ Yes ❑ No How Determined Impact Fee Amount $ /,l 2/. 0 1 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ /7� /� 7 7`D (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt b Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total� Zone TOTAL AMOUNT $ '7 ' /• 54 Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By r Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY • • • • • • • • • • • 60YINK.,, PERFORMANCE BUSINESS PRODUCTS,INC.813-719-8008 FAX 813-719-7919 CITY OF ZEPHYRHILLS ZEPHYRHILLS, FLORIDA WATER ACCT. NO. DATE -d OWNER/ RENTER vCu - MAILING I2O kj d S/ 962 SERVICE ADDRESS ! 5 TLkk I I kc JrY i( -- / s SHUT OFF SERVICE E ,dATER [� TURN ON SERVICE ❑ SEWER INSTALL METER ❑ GARBAGE READ METER ❑ �N CITY CHECK METER ❑ ❑ OUT CITY OTHER ❑ No.OF UNITS DEPOSIT AMOUNT I � AMOUNT LAST BILL S2-1 DATE � L MISC.CHARGE METER: full irrigation WORK COMPLETED BY ORDER TAKEN BY &DATE COMPLETED IBY Retain white form in office at all times. Send pink&yellow forms to Water Service Dept. Water Service Dept.to sign yellow form&return to office. 37549 DALIHA TERR LT#185 BLDG 19 MARTINIQUE LENNAR HOMES PRMT#8212 SQ.FEET PRICE MAIN OR LIVING: 1,663 $ 95.00 OTHER AREA UNDER ROOF: - $ 94.00 OTHER: - $ - VALUATION $ 157,985.00 FEE SHEET $ 654.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 727.08 ELECTRICAL: $ 147.15 PLUMBING: $ 98.10 MECHANICAL: $ 68.67 SUB-TOTAL $ 1,041.00 RADON: $ 16.63 TOTAL $ 1,057.63 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 220.00 3/4 meter IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 93.28 INSPECTION TOTAL: $ 13.50 PERMIT TOTAL TOTAL: $ 106.78 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,588.76 PARK IMPACT FEES $ 769.56 SIF'S: $ 1,740.00 100.0% $ 1,740.00 25%of tif is choose to pay$280.26 and pay 75%before pre-meter$3,367.71 1.0% $ 17.40 permit cost if paying 25%of tif$4,869.02****** TOTAL: $ 1,757.40 TIF'S:F'S: $ 1,121.01 Minus Credit-check on balance 99% $ 1,109.80 Minus Credit-check on balance 1% $ 11.21 Minus Credit-check on balance TOTAL: $ 8,236.73 FORM 600A-2004th cTirrtyyvztuyesa+•t.a.c FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: LHi531M-MARTINIQUE-1531 S.F.LNING AREABuilder. LENNAR HOMES Address: Permitting Office: (jc1 o1 Z ,,W City, State: Permit Number: ( 2(1 Owner. Jurisdiction Number- ( Climate Zone: Central 1. Now construction or existing ---- Now 12. Cooling systems ~' — 2. Single family or multi-family Multi-f mlty — a. Central Unit Cap:28.2 kBtu/hr 3. Number of units,if multi-family I SEER: 14-00 4. Number of Bedrooms 2 — b.N/A 5. Is this a worst case?. Yes — 6. Conditioned floor area(ft=) 1531 Ii' — c. N/A 7. Glass type'and area:(Label rcgd.by 13-104.4.5 if not dothult) a. U-factor; Description Area 13. Heating systems (or Single or Double DEFAULT) 7a (SDgle Default) 127.0 ft2 a. Electric Hcat Pump Cap:28.2 kBtu/Itr b.SHGC; HSPF:2.20 (or Clear or Tint DEFAULT) 7b. (Clcsr) 127.0 ft ' b.N/A •8. floor types P. Slab-On-Grade Edge Insulation R0.0,36.0(p)ft c. N/A b.Raised Wood,Post or Pier R=11.0,112.0ft' — c. N/A 14. I•lot water systems — 't 9. Wall types a. Electric Resistance Cap;40.0 gallons a. Concrete,Int instil,Exterior R=4.1,389.0 it — EF.0-92 b.N/A b.N/A —" c.N/A — d.N/A — o. Conservation credits _ c. N/A (HR-Heat recovery,Solar 10. Ceiling types — DHP-Dedicatad heat pump) a. Under Attic R-30.0,866.0 ft= 15. HVAC credits — b.N/A (CF-Ceiling fan,CV-Cross ventilation, C.N/A HP-Whole house fhn, 11. Ducts - -- PT-Pro ntmable Thermostat, " a. Sup:One. Ret;Con, AH(Seeled):Interior Sup.R6.0,150.0 ft MZ-C-Multizono cooling, LIN/A — ML-H-Multizone beating) Glass/Floor Area: 0.08 Total as-built points: 14112 PASS Total base points 16493 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in comp) ce ' e Florida E y specifications covered by this p�'l13B8T,8t�0 Code, calculation indicates compliance PREPARED BY: �.. with the Florida Energy Code. DATI=: �'X X Before eonstt` etion is completed this building will be inspected•for t9 , I hereby earthy that this building,a si eHsi c !lance compliance with Section 553.908 with the Florida Energy Code. Florida Statutes. OWNER/AGENT: BUILDING OFFICIAL: DATE• DATE: 1 Predominant glass type.For actual glass p and areas,see Summer&Winter Glass output on pages 2&4. —� EnergyGauge®(Version:FLRCSB v4.5.2) FORM 600A-20048 ci JUI yy¼Tauy v.L FLORIDA ENERGY EFFICIENCY C'O.D€ FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: LH1531 M-MARTINIQUE-1531 S.F.LMNG AREASuilder: LENNAR HOMES Address: Permitting Office: City,State: Permit Number. Owner. Jurisdiction Number: Climate Zone: Central —._.__ �J' 1. New conatruotion or existing New jJ 12. Cooling systems 2. Single family or multi-family Multi-Family _ a, Central Unit Cap:28.2 kBtwbr 3. Number of units,if multi-family I _ SEER: 14.00 4, Number of Bedrooms 2 b.N/A 5. Is this a worst case? Yes — 6. Conditioned floor area(ft') 1531 ft' c.NIA 7. Glass type I and area:(label rogd.by 13-104.4.5 if not default) a. U-factor: Description Ares 13, Heating systems (or Single or Double DEFAULT) 'fa ft2 (Sngle Default)127.0 _ a. Electric Hcat Pvmp Cap:28.2 kBtalhr b.SHGC: HSPF:8.20 (or Clear or That DEFAULT) 7b. (Clear)127.0 it' b.N/A 8. floor types a. Slab-On-Grade Edge Insulation R"O,O,36,0(p)(1 c, N/A b.Raised Wood,Post or Pier R=11.0,112.0ft _ -' c. N/A _ 14. I•lot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons a. Concrete,Int Insul,Exterior R'4,1,389.0 It' _ EF:0.92 b.N/A — b.N/A _ c.N/A d.N/A _ o.Conservation credits _ c. N/A (HR-Heal recovery,Solar 10. Ceiling types — DHP-Dedicated heat pump) a Under Attic R=30.0,866.0 ft' 15. HVAC credits b.N/A (CF-Ceiling fan,CV-Cross ventilation, c.N/A _ I F-Whole house fan, ii. Ducts PT-Programmable Thermostat, a. Sup:Ono. Ret;Con, AH(Sealed):lnterior Sup.R=6.0,150.0 ft MZ-C-Multlzonc cooling, LIWA _ MZ-H-Multlzone heating) Giass/Floor Area: 0.08 Total a5-built points: 14112 PASS Total base points: 16493 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compli ce a Florida E y specifications Covered by this04sOa Code. calpilation inditar<tes compliance PREPARED BY: �.. with the Florida Energy Code. DATE: �' Before construction is completed this building will be Inspected•for is ;a' , 1 hereby certify that this building, mpliance compliance with Section 553.9013 with the Florida Energy Code. Florida Statutes. �+ OWNER/AGENT: BUILDING OFFICIAL: _� DATE: 1 Predomin output ant gla4s type.For actual grass a and areas,see Summer&Winter Glass on pages 2&4. --- F_rtergyt3suge®(Version:FLRCSB v4.5.2) t"V.KNI oUUA-LUU4K �ticlyyvauyu,-r�u.:c SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , ,, P•ERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF=Pot'Poiirts :.: .16 1531.0 24.36 6710.0 1.Single,Clear W 1.3 6.0 32.0 57.68 0.94 1120 ` 2.Single,Clear W 6.0 4.0 7.0 ' 67.68 0.46 187-1. , .. 3.Single,Clear E 6.0 9.0 40.0 63.97 0.64 15420- 4.Single,Clear W 1,3 10.0 16,0 57.68 0.99 912,0 5,Single,Clear E 1,3 6.0 32.0 63.97 0,94 1917. As-Built Total: 127.0 636: . WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1,Concrete,int lnsul,Exterior 4.1 389.0 1.18 459.0 '' Exterior 389,0 1.90 739,1 Base Total: 389.0 739.1 A*-Built Total: 389.0 /° DOOR TYPES Area X BSPM = Points Type Area X SPM = Points '. Adjacent 0.0 0.00 0.0 1.Exterior Insulated 20.0 4.80 98y Exterior 20.0 4,80 96.0 ., Base Total: 20.0 96.0 As-Built Total: 20.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM= Points: ,• , Under Attic 866.0 2.13 1844.6 1.Under Attic 30.0 886.0 2.13 X 1.00 1844 ' - Base Total: 866.0 1644.6 As-Built Total: 866.0 16A4. FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Pois: Slab 36.0(p) -31.8 -1144.8 1.Slab-On-Grade Edge Insulation 0.0 36.0(p) -31.90 -1140:* , Raised 112.0 -3.43 -384,2 2.Raised Wood,Post or Pier 11.0 112.0 1.83 204'4 Base Total: -1829.0 As-Built Total: 148,0 .94*,Ø,♦ INFILTRATION Area X BSPM = Points , Area X SPM = Points,. 1531.0 14.31 21906.6 1531.0 14.31 21908,6,: EnergyGauge3l DCA Form SOOA-2004R EnergyGauge6vFIaRES'2004R FLRCSB v4.5.2 MAY-20-2008 10:38 FORM 600A-2004R EnergyvaugeV 4,5.1 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: ,,, PERMIT# BASE AS-BUILT Summer Base Points: 29769.3 Summer As-Built Points: 29749.2. Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Pointe (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 2o200btun,SF.ERIEFF(14.0)Ducts:Ufc(S).Con(R),Int(AH),RS.O(IN$) 29749 1.00 (1.08 x 1.150 x 0.85) 0.244 1.000 7687.5 29769.3 0.3250 9676.0 29749.2 1.00 1.061 0.244 1.000 7687.5 •• EnergyGougeTM DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRGSB v4.5.2 FORM 600A-2004R 1-nergyuaugew 4.5.1 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: ,,, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF=Poi 18 1531.0 9.11 2511.0 1,Single,Clear W 1.3 6D 32.0 13,25 1,01 427' 2.Single,Clear W 6.0 4.0 7.0 13.25 1.10 102!0 3.Sinele,Clear E 8.0 9.0 40.0 12.37 1.10 542:E> . 4,Single,Clear W 1,3 10.0 16.0 13.25 1.00 211,0 5-Single,Clear E 1.3 6.0 32.0 12.37 1.01 401.0 As-Built Total: 127.0 1 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Poi1fs, Adjacent 0.0 0.00 0.0 1.Concrete,Int Insul,Exterior 4.1 389,0 3.31 1286B 7` Exterior 389.0 2.00 770.0 _ Base Total: 389,0 778.0 As-Bunt Total: 389.0 1286,11. DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior insulated 20.0 5.10 102.6 Exterior 20.0 5,10 102.0 Base Total: 20.0 102.0 As-Built Total: 20.0 14 - CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM= Points:, Under Attic 886.0 0.64 554.2 1,Under Attic 30.0 866.0 0.84 X 1.00 554.2 Babe Total: 866.0 554.2 As-Built Total: 860.0 86U FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = PO1t>fis. Slab 360(p) -1.9 .68.4 1.Slab-On-Grade Edge Insulation 0.0 35.0(p) 2.50 90.0 . Raised 112.0 -0.20 -22.4 2.Raised Wood,Post or Pier 11.0 112.0 0.47 52,8 Base Total: -90.8 As-Built Total: 148.0 144.8' r. INFILTRATION Area X BWPM = Points Area X WPM = Points. 1531.0 -0.28 .428,7 1631.0 '.0.28 426.7. EnergYGauge®DCA Form 600A-20048 EnergyQauge®/FIaRE5'2004R FLRCSB v4.5.2 rvr ivi ovv'. -wu'+k nsrgy.,auge�ts►4.o.L WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: ,, , PERMIT#: BASE AS-BUILT Winter Base Points: 3425.8 Winter As-Built Points: 3339.'0. Total Winter X System Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Electric Heat Pump 28200 btuh,EFF(8.2)Ducts:Unc(S),Con(R),lnt(AH),R6.0 3338,0 1.000 (1.068 x 1.180 x 0.87)0,416 1.000 1504.8 3425.8 0.6540 1897.9 3339.0 1.00 1.083 0:416 1.000 1504.8. EnergypaugeTM DCA Form 600A-2004R EnergyGauge®1FIaRES'2004R FLRCSB v4.5.2 rVflIVI UVUN- UUrrc tnergy iuew't. . WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: ,,, PERMIT#: 1 BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.•0 As-Built Total: 4920;9•: •r.. CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water - Total Cooling + Heating + Hot Water Total Points Points Points Points Points Points Points - Points 9675 1898 4920 16493 7688 1505 4920 14112 . LPAss - 1 O48 • +�,oD hrs 1 EnergyGaugeTM DCA Form 600A-20048 EnergyGauge®IFlaRE$'2004R FLRCSB v4.5.2 • FORM 6OOA-1UU4R tnergyuauyeev q.3c Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: ,, , PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SEQTION -,-� REQUIREMENTS FOR EACH PRACTICE _-. CH1rCK Exterior Wirldow,s$Door .1.1 iV aximum:,3 cm/q,window area 5 cfm/sq.ft.door area. Exterior&Adjacent Walls 608.1.ASC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;Joints between exterior wall panels at comers;utility penetrations:between wall panels&top/bottom plates;between walls and floor. EXCEPTION;Frame walls where a continuous infiltration barrier Is Installed that extends ___.. ___„ from nd is sealed to, e foundation to the top plate. _ Floors 606.1 ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier Is Installed that Is sealed —_, to the perimeter,penetrations and seams. .- Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor,around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier,gaps In gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that i$Jealetl at the perimeter,at penehations and seams. ____ Recessed Lighting Fixtures l 606.1.A6C,1.2,4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,Installed Inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from _.. —_---•_ conditioned space,tested. Multisto ii_ouses t*,08ABC.1.2.5 Alr barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606,1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS - ____ Water Heaters 612.1 Comply with efficiency requirements in Table 612.1 ABC.3.2.Switch or clearly marked cir u ....breaker_ bleaker(electric)or cutoff(gas)must be provided.,External or built-In hest trap required. ^4? Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools .. must have a pump timer,Gas spa&pool heaters must have a minimum thermal _...? - n of76"A. Shower s 612,1 Water flow must be restricted to no more than 2,5 gallons peer minute at 00 PSIG. - Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and Installed'a1 accordance with the criteria of Section 610. in uncondftioned att1 _R-e min,inaulaflon. HVAC Controls __ 607.1 Se arrate re jy eca ible manual or autofAtic thermostat for each 5xetern. Insulation 604.1,602.1 CNMgs-Min.R-19.Common walls-Frarha R-11 or CBS R3 both sides. Common calling&floors R-1 1. EnergyGaugeTM DCA Form BODA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 • • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE*=88.5 The higher the score,the more efficient the home. 1. New construction or existing New •- 12. Cooling systems 2. Single family or multi-family Multi-family _ a. Central Unit Cop:28.2 kBtu/hr 3. Number of units,if multi-family I _ SEER:14.00 4. Number of Bedrooms 2 _ b.N/A —• ' 5. is this a worst case? _ " . 6. Conditioned floor area(R') 1531 fl' c.N/A 7. Gifts ty,el and area(Label read.by 13.104,4.5 if not default) , a, U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sagie Default)127,0 ft' a. Electric Heat Pump Cap:282 kBtu/hr ' b.SHOO: HSPF:8.20 (or Cicar or Tint DEFAULT) 7b. (Clear)127.0 ft2 _ b.N/A • 8. Floor types a. Slab-On-Grade Edge Insulation RR0.0,36.0(p)ft — c. N/A b.Raised Wood.Post or Pier R=11.0,112.0ft' c•N/A 14. Hot water systems S. 9. Walt types a. Electric Resistance Cap:40.0 gallons a. Concrete,int lnsul,Exterior R=4,I,389.0 ft2 _ EF.0.92 _ b.N/A b.N/A c.N/A _ d.N/A _ c. Conservation credits e. N/A ^, (HR heat rccovcry,Solar - 10. Coiling types DHP-Dedicated heat pump) ..< a. Under Attic R=30.0,866.0 ft' _ 15. 11VAC credits _ b.N/A __ (CF-Ceiling fan,CV-Cress ventilation, c.N/A HF-Whole house fan, !!. Duets PT-Programmable Thermostat, a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft _ ML-C-Multlzonc cooling, b.N/A M7,-H-Multlzone heatiag) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above ener sa features which will be installed(or exceeded) oB in this home before final inspe e,a new EPL Display Card will be completed based on installed Code 11 ., Builder Signature: Date: r ♦' Address of New Yiome: City/F[,Zip: %o, .Ø# ws *NOTE: The home's estimated energy performance score is only available through the FLA/RES'computer program, hts is nor a Building Energy Rating.{f your score is 80 or greater(or 86for a US EPA/DOE Energ&StarTdesignation), your home may qualify for energy efficiency mortgage(REM)incentives#'you obtain a Florida Energy Gauge hating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web sire at www;facauedufor information and a list of certified Racers. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487.1824. I Predominant glass type.For actual glass type and areas,see Sumner&W' ter Qless outtp�u�t ages 2&4. Energyt3augetBl(Version:FLRGSB v4.5.2) Load Short Form Job: MARTINIQUE-15315.... write Dom: 11/1712007 Entire House By: TR" SIMPSON MECHANICAL For. LENNAR HOMES • Htg Cig Infiltration Outside db(°F) 40 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TO(°F) 30 17 Fireplaces 0 Dally range - L Inside humidity(%) 50 50 Moisture difference(gr/lb) 25 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade 14HPX Series Trade 14HPX Series Model 14HPX-030-230/* Cond 14HPX-030-230/' Coil CBX26UH-030* Efficiency 8.2 HSPF Efficiency 14 EER Heating Input Sensible cooling 22278 Btuh Heating output 28200 Btuh Q 47°F Latent cooling 5922 Btuh Temperature rise 26 °F Total cooling 28200. Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.84 ROOM NAME Area Htg load Cig load Htg AVF Cig AVF (ft') (Btuh) (Btuh) (cfm) (cfm) FOYER 68 2777 1980 122 98 KITCHEN-NOOK 100 1834 1811 81 90 DINING 160 1622 384 71 19 POWDER-STAIRS 131 1269 301 56 15 LIVING 297 7432 5376 328 266 STAIRS-HALL 102 446 382 20 19 MASTER B.R. 239 3206 4484 141 222 MASTER BATH 58 195 176 9 9 FLEX.ROOM 146 686 581 30 29 HALL BATH 68 195 176 9 9 B.R.#2 2 174 3025 4534 133 225 BOW4btge Values hive been menualry ovenfdden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghrsoft RiwsSWte Resldenthd&.0.107 RSR29019 2005a.Aay-20093428 ,�`A z:lrommy WACLN1531MJB.t►p Cate'MJB oderaa0on-W Page I Entire House 1531 22686 20186 1000 1000 Other equip loads 1059 614 Equip. 0.97 RSM 20259 Latent cooling 3824 TOTALS 1531 23745 24083 1000 1000 Bold/Italic values eava bean manually o✓etftdden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft Ri ht-Butte ResmanUal 6.0.107 R5R2997a 2008-May-200934 a Z%Tommy HVACLL H1531 MJR." Colo-MJS Odsnlaaon r W pogo 2 • 1f . TOTAL P.11 City.of Zephyrhills BUILDING PLAN REVIEW COM1v1EENTS. Contractor/Home owner: �i1lA-✓ `�l Date Received: �� v Site: t Cl 1� Permit Type: w/the below comments: Denied w/the below comments: Approved w/no comments:❑ Approved . This comment sheetshall be kept with the.permit and/or plans. Kalvin Switzer— ans Examiner ate Contractor.and/or Homeowner (Required when comments are present) 813-78U-UUZU Ity UI LCpi Iyi 11111O rc1II IIt r_ i,JIJ I II cuVI T i Building Department ` &, �l v Date Received 8 9/8 -- X)539 HOSES Phone Contact for Permitting / Owner's Name ri Ae1VA1A< OSES Owner Phone Number (813) 76 9 `S2 77 Owner's Address InOO N• a0SrfMot,E f31-v0 '4A FL33(,0q Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3754c1 PAS.///A TER. ZE, '//yRN/LL,S i FL LOT# IS SUBDIVISION /4NL i' 94- PARCEL ID#1 0 3-2 ,-2/"023 0- 00000- / 50 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® NEW CONSTR ADD/ALT SIGN O MOVE DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL OTHER DESCRIPTION OF WORK I /Y66WJ �N,S-rX t1Cr,o -- 7.10 fj,Jn/',<, o/✓f�S BUILDING SIZE I I SQ FOOTAGE 15 31 HEIGHT I BUILDING 31, 6 co I VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY 0 W.R.E.C, fl PLUMBING $ MECHANICAL $ 4/• VALUATION OF MECHANICAL INSTALLATION GAS ROOFING O SPECIALTY OTHER FINISHED FLOOR ELEVATIONS y� s FLOOD ZONE AREA DYES =NO IIIJIIIIIIIIIIIIIIIIlIiIIIIiI BUILDER COMPANY ZSN/t//4A—" !7 D: ,5S SIGNATURE REGISTERED Y/ N FEE CURRENT LY/N Address Ooh/ Gc/ ci 8i , A 33O License# CSC/ . .5si≤I I ELECTRICIAN COMPANY I d A/ EGEC?Se/L �l/koHN , Z LB SIGNATURE IREGISTERED Y/ N FEE CURRENT Y/N Address �/ E. Oc 'V'0, Si- Lp c 'i /'L 3308/ I License# C/3 00 ,S (v (o PLUMBER COMPANY Alfrvt/R .�c//LEM�9�/ t utrre�n/ SIGNATURE REGISTERED Li] N I FEE CURRENT Y/N Address iqq29 44c 33(.,/3jLicense# CFO y/ 72 / MECHANICAL COMPANY 84yo1✓ETguMQ ,�/G ,: Ef/Ti•V�,Af{G' SIGNATURE REGISTERED I Y/ N FEE CURRENT Y/N Address I I . 8o S3 c34 oNFr'/NT 3W,?Vl 3W,? License# �fti C OsS ©(0 2 OTHER COMPANY C. JTE/ L/ J ''1 v AdO T . Svc. SIGNATURE REGISTERED Y/ N I FEE CURRENT Y/N Address .S//OAL L/w 8t..vp c.$P2i/V6///�L ,CL3Y6o 7 License# j _CO 5199 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities& 1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite, Construction Plans,Stormwater Plans wl Slit Fence Installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500, a Notice of Commencement is required, (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter If on public roadways,.needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands lthat assumes responsibility permiay be bj ct oc a'deed" re with restrictions" i any which may be more restrictive than County regulations. The undersigned nde g applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRAcTOR ePON IBILITIESin iffe with o owner te and local has hir egulcontr ctorth or contractors to undertake work,.they may be require to bbe licensed e contractor Is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. if the owner or Intended contractor are uncertain as to what licensing requirements may apply or intended work, they are advised to contact ea contractor sco County orBuilding tractorsPehei�s n adv sed toicensing Section at have the contractors)s4gn 7- 8009. Furthermore, if the owner has hired portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITiESIMP Recovery RESOURCE SOes RCE RECOV to ERcY'FEES: Thstruction e undersigned new debgn d understands d f that Transportation Impact Fees and Recourse 7 and use in existing buildings, or expansion of existing understands, that that such fees,.as may be due i Pasco t'ill Ordinance be identified at the'ttiime of 90-07, as amended. The undersigned also dersta Tranon t and ce Recovery Fee.s be aid prior permitting. It is further understood that finals power tl elease cIf these project doesrnot involve a certificate tof occupancy pancy or o receiving a "certificate of occupancy" final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes,ooysof amended): aF"Florida Couation of Work nstruction n Liens L aw—Homeowner's 2,500.00 or more, I certify that I, the applicant, have been prove Protection Guide" prepared by the I have obtained, a copy of the above described document Florida lr it docum and prominsumer sers. If the faith to is someone other than the "owner", I certify t deliver it to the "owner" prior to commencement. ) that l rmation n this ccurate CONTRACTOR'SIOWNER'S AFFIDAVIT:applicable laws regulating regulating construction,uction,i zoning application Id laind development.to Application is d that all work will be done in compliance with all pprtify hereby made to obtain a permit to do work and installation will benperformedi toemeettstandards of all laws installation rreg regulating commenced prior to issuance of a permit and that all o construction, County and City codes, zoning regulations,overnmenland t agenevelopment cies es may apply regulations in the intended work, aind thatit is certify that I understand that the regulations ofmust othtake g my responsibility to identify what actions I m rotectibn-. be in Cypressmpliance.Bayheads, Wetland Areas and Environmentally ytSensitive - Department of Environmental P Lands, Water/Wastewater Treatment.- Ba heads, Wetland Areas, Altering Southwest Florida Water Management District-Wells, Cypress Y Watercourses. i - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks.- I US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. Ian addressing a If the fill material is to bll be submitted at time of that a permitting which is prepared agprofessional engineer "compensating volume" wi licensed by the State of Florida. If the fill mat*ial is to be used in Flood Zone "A" in aconnection rea within twith. a wall. building using stem wall construction, I is certify that fill will i be used only to rtl the use of such be cited for adjacent i jace t _ If fill material is to be used in any area, I Ce f that properties, thewill not mayrsely affect adjace1 t g properties. If use of fill is found to adversely affect adjacent the conditions of the building permit issued under the attached permit application, for lots less than one ) acre which are elevated by fill, an engineered drainage plan Is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in s not specifically included in the application. A to commencing construction. I understand, that Ia lat oparate permit may be required for electrical work, this affidavit prior as, or other installations plumbing, signs, wells, pools, air conditioning, g issuance of a permit prevent the Building Official fro Invalid issued shall be construed to be a license to proceed with the work and note authority to.in violate, c rom e alter, permit permit issued shall become er set aside any provisions of the techical codes, nor shall' codes. Every requiring a correction of errors in plans, construction or violations of any authorized by such permit is commenced within six months f e�the time p permit issuance,ork commenced. An extension by unless the work eriod of six (6) monthsdays and will demonstrate the permit is suspended or abandoned for a p be requested, es for alni for (90)' consecutive days, the job is considered abandoned. a in writing, from the Building Official for a period not to exceed ninety (90) Y. may justifiable cause for the extension. If work TeaMAY FAILURE TO RECORD A NOTICE OF COEN T OMEN N F NANC NG,TCONSOULT WARNING TO OWNER: YOUR O YOUR PROPERTY• IF YOU INT CO CEMENT. PAYING TWICE FOR IMPRO O E BEFORE RECORDING YOUR NO I WITH YOUR LENDER FLORIDA JURAT(F.S. 117 CONTRACTOR his Subscribed and sworn (or affil efo OWNER OR AGENT me this $TW, by `7" Subscribed and sworn to �E` o me r haslhave produced �a duce Who islare personaiiv Icact _. as Identification. Who Isla°Wally known to mas Identificatioas/ n. Notary Public Notary Public �0 Commission No. commission No. ed, rinted or st Name of ary tYP p ,,,, n•^y� Commission DD 77 O 3 Name o LI /� OLLERAN ,,; :k: Commission DD 774023 Expires June 6,2012 Expires June 6,2012 p••• * Bonded TAru Troy Fain Insurance 800.3857019 ' Q�`, Bonded Thru Tray FainInsurance800-385-7019 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII!I 2008129033 VIII VIII Ii!!IIII STATE OF FLORIDA COUNTY OF PASCO Rcpt: 1201266 THIS IS TO CERTIFY THAT THE FOREGOING IS A 0S: 0.00 RIT: . 00 TRUE AND CORRECT COPY OF THE DOCUM NT ON FILE 09/04/08 IT: 0 00 OF PUBLIC RECORD IN THIS OFFIC DPty Clerk HAN ND OFFICIALS AL THIS TNESS MY DAY OF ITT 2 JED N PaCO COUNTY CLERK CLE K OF IRCUIT URT 09/044/08/08 lfd:59amS CLERK OR BK 7918 PG 8g@ NOTICE OF COMMENCEMENT Permit No. Property Identification No,'03-2 .- /- ro 0 /2SO THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property, Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT accordance with 1.Description of property(legal description;) Lor /5..( , tLNNA 4JC /wo, rs P$(d4 P / er a)Street Address: 37 54'9 2.General description of improvements: j/ pe,4E feA,w,.,, _ jprc /floc L 3.Owner Information a)Name and address: WNAie -Ho,1E4 ,ZNC�.� �,oo 41 a6sr.r 0 Lv wpy � 31 0 b)Name and address of fee simple titleholder(if other than owner) c)Interest in property 4 tractor Information ■ a)Name and address: .Yrzye,S'r,,irN-- (000 Al Wesrs,,io2E l3LVD.T TE 600 Tq, a ctT 34oq b)Telephone No.: (g I3) 7(.q SZ?7 Fax No. (Opt.) 5.Surety Information a)Name and address: /,//,g. b)Amount of Bond: N/,q c)Telephone No.: Fax No, (Opt.) 6.Lender ( p •) a)Name and address: Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a)Name and address: (a 4/. 4f . rl,VoRf 'Lvo, .SrE doo , T,ony eA F[ 3.3se9 b)Telephone No.: ($ ►3) 7`9 S2 77 Fax No. (Opt.) 8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided.in Section 713.13(1)(b),Florida Statutes: a)Name and address: N�.f b)Telephone No.: .Fax No.(Opt.) 9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is. specified); WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS.UNDER CHAPTER 713,PART I,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR.RROPERTy. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE ;RST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY'BEFORE. COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PASCO _ Signs re o wner's Authorized Officer/Director/Par4ier,?iariager cyy5c J ,4/S Print Name The foregoing instrument was acknowledged before me this 28'H day of '-'1 ZOO 4 ,by H e N,f Et k. .5'7E4, M5 as A'l4N4< E2 in fact)for LENNA� orePoRAT/o Al name of (hope of thority,e.g.officer,trustee,attorney ( party on behalf of whom • eat was Executed), Personally Known ✓ OR Produced Identification Notary Signature . Type of Identification Produced Name(print) L.! S S'q /y ih'- . io Verification pursuant to Section 92.525,Florida Statutes.Under penalties of.perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief " ELISSA M.HOLLERAN Signal nm of rai rson.Si Above FORMSINOC,rvad200T �c' '= Commission DD 774023 a s Expires June 6,2012 %�, ,,,.• Ba+dedThiuTroYFrnlinauKe80D.3B6.7�tY CE !!Tr;AL_ FEFMCTTING, nf: :: „ : . ..,..,.. P!Tf i l i i ( rt 1::. �:.xx L': :'.L I'lf1f�41:::r L..fadi�l jl;; .T.r�MI'�'t ::O:Ct1:C :Sa:i::)f l RECEIPT i.u..�i�ii. I:i i.a. 1)1)I ,00 ii I.AJl:::2a.T..yi>l Ill ii:l..VD `::SI) I:T I..: Yfri{) t.....:.xx . .. ... ...:: F•t:iRN :I. T)fll...:l:i•If;f##:I.{ .f 1...•T•##:I. CI..IE:(::h:: # :1. 8 :l: T'•'r' :r•.f.l••l1:1...1...:::; F;;i:: (:)i iI::i":I::. 229999 T(:rr I... AMOI.JNT'a 4.,42 (::N I (: ' MI'Y 1',(:;(:;(:JI•,14 T• (:;I..:(•'1 I AMOI.IN I )I ' It:I:l'.T..:I ON;'I::i:::E;;M J.:14 8.450 2 4 x #:.''. SOL...II WASTE FEE . F:I:::CE.1:VED) C:+Y