Loading...
HomeMy WebLinkAbout08-8362 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8362 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL Permit#:8362 Issued: 10/06/2008 Address: 36301 DELTA GOLD CT LT#5 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 219,126.29 Total Fees: 11,173.82 Subdivision: SILVERADO Amount Paid: 2,803.98 Date Paid: 10/06/200 Parcel Number: 04-26-21-0060-00100-0050 Name: WINDWARD HOMES Name: WINDWARD HOMES Addr: 5439 BEAUMONT CIRCLE BLVD#1050 Address: 5439 BEAUMONT CTR BLVD#1050 TAMPA FL 33634 TAMPA, FL 33634 Phone: (813)885-7744 Lic: Phone: (813)885-7744 Work Desc: NEW SINGLE FAMILY RESIDENCE (2263 SQ FT) BUILDING FEE 916.80 ELECTRICAL FEE 189.00 PLUMBING FEE 126.00 MECHANICAL FEE 88.20 RADON 22.63 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 48.28 SCHOOL IMPACT FEE-sfr/100% 4,828.00 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 dF •i �'��o" t$ cif ® 3r xF -k "" ii € n .9: .€'P..3: - Yag�� r 'h:. ..� f�.� �,�', E. ,i �''�..° . - -�°.��:�S a s °,,k...� r o��. ' A FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twke for improvements to your property. to obtain financing,consult with your lender or an attorney before recd ing your nticç6fcom encement." RACTOR GNATURE PERMIT OFFI PERMIT EXPIRES IN ONTHS ITHOUT APPROVED INSPECTIO CALL FOR INSPECTI - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF / / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION DAT illy�- ) l PERMIT f��VZ THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be mode before the job will be accepted. S I L ) It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL. cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation.OFFICE HOURS 7:30 AM-4:30 PM MON.-FRI. INSPECTOR CITY OF / / / / BUILDING ZEPHYRHILLS "l 01 I DEPARTMENT OF ADDITION OR CORRECTION ADDRESS DAT PERMIT f ~�� /z7iof THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be mode before the job will be accepted. : &Tfi u w\ -tic Tzc 7' C._C, f'Zfj'( '])Z -- rt A iL 7T C1 AP It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MA E ALL C. i cover or cause to be covered,any part of the work with flooring,lath,earth 7800020 OR R -INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR ,�; � �� ,. .. .. ,. .. rikv . �.- �� �. � ` w ,�::, To: 8137800021 From: Carole Bradley PG-TD-K. Hovnanian Homes Date: November 03, 200818:42:22 GMT Subj: 7XALF1 ZI56 Pages: 2 TO : 8137800021 FROM : Carole Bradley COMPANY : PG-TD-K. Hovnanian Homes SUBJECT: Silverado Ranch Lot 5 - Permit #8362 e-Builder PROJECT : Silverado Ranch Phases 1A & 1B DATE / TIME (GMT) : 11/3/2008 6:42:09 PM MESSAGE: Please see the attached Form Tie-In survey for Silverado Ranch Lot 5 Documents Included in this fax: zy002-006-0001-formsurvey.pdf arCr 1 Z aolC. � t NC��j I �r A yOOA IV o° i0 aqP�t -� in2�Z SR `. 0 i k a L. 5E ,OO'8tl M ,OO. .OO \ 1D N a } '. Yin R $ N o B I e i4� �Sr S: iA i N tH & 3iz33 _• ja 4 I o nl 'Q,j � �Q'��v ti I I '✓ I 2 GS > .............. a Z : I � f� p q. A C JO l I _r Z � v liii ��� b < $ i§ 0 c" �i J I $$ �p z �ppg��p .�r� �$�� k�cm r� r I 3 ^ z 29133 L R � � $ � wear Am rn fe g �� iQ NI�2v 'yp 2 3 .Ob94'AO u 7 �S NAC Z U `� S'�n inn,y V1 TRACT'R' fV =6- i, Prepared by and Return to: 111111111111110111111111111111111111111111111111111111!IIII Paul corace,V.P.of Land Development for ",Hc'nianian Windward Homes, LLC 2008145610 5439 Beaumont Center Boulevard, #1050 Tampa, Florida 33634 Rcpt: 1206978 Rec: 18.50 DS: 0.00 IT: 0.00 10/06/08 Dpty Clerk 10/06%08 A01:40pmD IC0UNTS CLERK OR BK 7g41 P� 241 NOTICE OF COMMENCEMENT Permit No. Tax Folio/Parcel ID: _ State: Florida County: Pasco 04-26-21-0060-00100-0050 The undersigned hereby gives notice that improvement will be made to certain real property and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of property: 36301 Delta Gold Court Street Address: Lot 5 Block I of SILVERAD0,PHASE 1A, according to the Plat thereof as recorded in Plat Book 61, Page(s) 71, of the Public Records of Pasco County, Florida. 2. General description of improvement: Construction of a Single Family Dwelling and Pool and Pool Enclosure. 3. Owner: a. Name and Address: K. Hovnanian Windward Homes, LLC, 5439 Beaumont Center Boulevard, Suite 1050, Tampa, Florida 33634 b. Interest in property: Fee Simple c. Name and address of fee simple title holder (if other than owner): n/a 4. Contractor: a. Name and Address: K. Hovnanian Windward Homes, LLC, 5439 Beaumont Center Boulevard, Suite 1050, Tampa, Florida 33634 b. Contractor Phone Number: 813-885-7744 ' 5. Surety: a. Name and Address: n/a n/a b. Phone Number: n/a c. Amount of bond: $ n/a 6. Lender: a. Name and Address: n/a b. Lender's Phone Number: n/a 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a) 7, Florida Statutes: a. K. Hovnanian Windward Homes, LLC, 5439 Beaumont Center Boulevard, Suite 1050 b. Phone numbers of designated persons: 813-885-7744 8. In addition to him/herself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes: a. n/a b. n/a 9. Notice of Commencement expiration date (one full year from the date of recording unless different date is specified): OR BK 7941 PC 242 2 of 2 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. a_ OG 13a lac Paul Corace, Vice President of Land Development Date State of Florida County of Hillsborough T foregoing instrument was acknowledged before me this ' 3t9Oby Paul Corace, ice P sident of Land Development for K. Hovnanian Windward Homes, LLC, a Florida Limited Liability Compay. ry Public ,, CAROLEM,BI Mr�taMMi5a1oN�t1D� My Commission Expires: ,ii fNwN�wttunax° Personally Known X -OR- Produced Identification Verification pursuant to Section 92.525, Florida Statutes: Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my kn wiedge an ef. (kAe Paul Corace, Vic President of Land Development K. Hovnanian Windward Homes, LLC STATE OF FLORIDA COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HA y,D OF ICIAL SEAL"HIS DAY OF JED CLE IRCUIT OURT B CLERK Fax-813-780-0021 s13 7so 002o City of Zephyrhills Permit Application Building Department JI' Date Received Phone Contact for Permitting Owner's Name Owner Phone Number Owner's Address I 5439 Beaumont Cntr Blvd. #1 050 Tampa, FL Owner Phone Number 33634 Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3(e3°\ -(` v/ v1d c^ LOT# II SUBDIVISION S i I VI(c-&d 0 PARCEL ID# 4-2-(/r a l _ VoLaD 0 y\Do -o0s (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR ADD/ALT 0 SIGN MOVE Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM 0 OTHER TYPE OF CONSTRUCTION �r n�BL<OCK A FRAME Q STEEL Q OTHER I -� DESCRIPTION OF WORK �,0� (,t G) i JG L fM4 I t- 1W ( '"Jv 4L '' BUILDING SIZE � X SQ FOOTAGE �� HEIGHT BUILDING l, dO • o D VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 1 1 D 5D�i AMP SERVICE Q PROGRESS ENERGY W.R.E.C. . o PLUMBING $ S ' . ai7 MECHANICAL $ 5 c O c.7 VALUATION OF MECHANICAL INSTALLATION 0 GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I q FLOOD ZONE AREA OYES �O BUILDER J COMPANY Windward Homes SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N Address 3634 License# 'C ('1 ELECTRICIAN I COMPANY S & S Electric CO. SIGNATURE GL 4 REGISTERED Y/ N I FEE CURRENT I Y/N ao393L Address 05 Douglas Rd. Oldsmar License# PLUMBER i COMPANY R.J. Kielty Plumbing SIGNATURE 4 C1 REGISTERED Y/ N FEE CURRENT Y/N Address V9s)07 SR 52 Hudson, FL 34 69 License# ��n _� MECHANICA NN COMPANY Simpson Mechanical SIGNATURE REGISTERED Y/ N FEE CURRENT I Y/N Address 1[ 2302 N. Nhrisk A7e Tampa FL 3312 License# CMC056976 OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT Y/N Address I License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Sanitary Facilities&1 dumpster COMMERCIAL Attach(3)sets of Building Plans;(1)set of Energy Forms. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Sanitary Facilities&I dumpster All commercial requirements must meet compliance. SIGN PERMIT Attach(2)sets of Engineered Plans. `"`PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has Hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER R AN ATTORNEY B ORE RECORDING YOUR OTICE OF O FLORIDA JURAT(F.S. 117 3) OWNER OR AGEN \ TRACTOR( &() cribe a s n r e bef this Su ribed d sworn to(or affirrr ed) r me tpien` y by-_-- I I Wh /ar personal own to me r has/have produced personally known to or has/have produced s identification. as identification. ____________ fl 'A Notary Public Notary Public Commi n No. Commission No. JP, � Ygy CAROLEM.BRADLEY ?Q •.N _ CAROLE M.BRADLEY ==4'' N#DD 486545 Name of Nota jt Name of Notary ty or gpEplRl�cfOctober 8,2009 tober 8,2009 Bonded Thru Notary Public Underwriters ;F f c Bonded Thru Notary Publis Undinvriters °t vcawf�s^na'+s�'® 36301 DELTA GOLD CT LT#5-2263 SQ FT-WINWARD HOMES PERMIT#8362 SQ. FEET PRICE MAIN OR LIVING: 2,263 $ 96.83 OTHER AREA UNDER ROOF: - $ 91.00 OTHER: - $ - VALUATION $ 219,126.29 FEE SHEET $ 840.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 916.80 ELECTRICAL: $ 189.00 PLUMBING: $ 126.00 MECHANICAL: $ 88.20 SUB-TOTAL $ 1,320.00 RADON: $ 22.63 TOTAL $ 1,342.63 SEWER: N/A WATER: N/A IRRIGATION: $ TOTAL: $ / WATER METER: N/A l 3 Q L ,/ IRRIGATION METER $ - ._. ............. FIRE DEPARTMENT FEES PLANS TOTAL: N/A [J )j2 ` TI INSPECTION TOTAL: N/A PERMIT TOTAL N/A (� TOTAL: $ - _ PUBLIC SAFETY IMPACT FEES -� C' y POLICE $ 254.00 ( a l FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 1,895.98 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 25% PAYING$2,803.98 —Qd. CbC 1 3XQ (� 99%_$ 3,595.68 75% DUE$8,369.84 DUE BEFORE PRE METER 1%_$ 36.32 TOTAL: $ 11,173.82 Plan review Comments 1&2 Family Dwelling 1. F.F.E. Shall be a minimum of 8" above the road elevation and a engineered site plan. 2. Lots shall be graded to comply with 401.3 of the F.B.C. 3. Drainage plan requirements shall be made before pre-slab inspection. Ordinance #974-07 section 6. 4. Compaction test required if 24" or more of fill dirt is brought in at any one place. 5. Tie in survey required before pouring concrete. 6. Driveways require a R.O.W. use permit. 7. All setbacks shall be met. 8. All property markers shall be uncovered and marked at time of first inspection. 9. All A.D.A. requirements shall be met. 10. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 11. Return air in all bedrooms. F.B.C. M1620.4 12. Smoke detectors are to be installed in accordance with 313.1 of the F.B.C. 13. All glazing requirements are to be in accordance with 308.4 of the F.B.C. 14. All means of egress are to be in accordance with 311 of the F.B.C. 15. Combination-type AFCI breakers are required at all locations requiring a AFCI type breaker 16. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 17. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code R.O.W.-Right Of Way A.D.A.-Americans with Disabilities Act PASCO COUNTY; .FLORIDA Permit No. U 3 2- Date Permitted Builder NamelDwner Name l n+cN�✓� 4-�yv�•e-5 Control# Zto 2E- oo( o"batao_a� subDiv: SL L b County Parcel No. U`4" 5. • Address/Location 3b 3a I _14 -o C'- ClassifloationTType of Us �2� dn.- �, � TRANSPORTATION IMPACT FEE Rate: • �3 Sq Ft Unit; Z- 2A3 Exempt ❑ Yes [] No How Deierrnined Impact Fee Amount $ 3 �11�:1 2 , Zone-No.. ______---TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 't Z •(057) Mobile Horne • (058). •Other Residential . d 23) Collection Fee Exempt Yes Q No How Pateimined FARKB AND RECREATION FEE Land Total Land Account Land Credit . • Recreation Account Bcr cation Credit ' Recreation Total_ R Zone - TOTAL•AMOUNT'• $ �9 S Exempt D Yes ❑ No How.Determined LIBRARY FEE Land Total Land Account•' Land Credit Facility Account ___T____ Facility Credit Facility Total Exempt' ❑Yes . ❑ No How Dete ned Total Amount • RESOURCE FEE ERU TOTAL AMOUNT .. . Prepared By Checked By • NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED I.lNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A GENTRAJ-PERMITTING OFFICE.OF PASCO COUNTY Acknoyviedgement below does not Imply ac cepta�ce of concurrenoe,-but'simply receipt of a copy of this form,placing . the building permit owner an notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PLOT PLAN SKETCH ONLY SEC. 04 , TWP. 26 S, RNG. 21E. LOT 5, BLOCK 1 NOT A BOUNDARY SURVEY BEARING BASIS: SILVERADO - PHASE 1A PASCO COUNTY, FLORIDA. NORTHERLY LOT LINE OF LOT 5. BLOCK 1 BEING N 89'44'00" E THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRA VYING• MAY BE DISCLOSED BY A FULL AND ACCURATE THIS PLAN IS FOR PERMITTING PURPOSES 1A T TITLE SEARCH. ALSO SUBJECT TO SETBACKS, EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. p UNDERGROUND FOOTER. STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: a SHOWN. �--� = PROPOSED DRAINAGE FLOW DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00)- = PROPOSED GRADE NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE NOTES: DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN LOT GRADING TYPE = A PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = 98.90' CHANGE AND/OR REVISION. FRONT SETBACK = 20' SIDE SETBACK = 5' CERTAIN DATA SHOWN HEREON BASED ON REAR SETBACK = 15' ENGINEERING PLANS PROVIDED BY CLIENT. TRACT 107 STRUCTURE TIES SHOWN HEREON DENOTES ZHCCL, P.0.1, PAGE 55 MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. * = 10' UTILITY EASEMENT **MF� = 10' LANDSCAPE BUFFER/WALL EASEMENT so� N 89'44'00" E 163.93' _ PLAT ** BOUNDARY - - - - - - - - - - - - - - - - - - `991a� - - - - - - -�0� DNo� �Qv 0 cna.10 ? �Z 'N �O �W Vi U rTl w Oz 37.55' ZZ O qN BLOCK 1 O ( O o 5 LOT 6 BLOCK 1 CV . X60 0 . rye. t19 a 96.90) CP(P) .c� TOTAL LOT AREA = 15113.83_SQ. FT. DELTA G 0 LD TOTAL SOD AREA = 54 -SQ. FT. TOTAL CONC AREA _ 766 -__SQ. FT. COURT NQ ay �� gb HOUSE = 372 __SQ. FT, (O.R.7289, PG.1224) LOT OCCUPIED =-- -----�° SETTLERS COURT(PLAT) m. NOTE: (R/W VARIES) CONC AREA NOT UNDER ROOF PCP(P)J pI OONT PROPOSED I CURVE I RADIUS I ARC I DELTA ANGLE I CHORD I BEARING I LOWEST FLOOR ELEVATIONS: I C19 I 52.00' I 44.66' I 49'12'46" 43.30' I N 6539'37" W I LIVING AREA: 99.20' GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO LOT 5, BLOCK 1, MAP OR PLAT ENTITLED "SILVERADO - PHASE NATIONAL GEODETIC VERTICAL 1A", AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75, DATUM OF 1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0298 D EFFECTIVE DATE: 9/30/92 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA. (P)= PLAT DATA, {= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING. CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED IPE, LFE= LOWEST FLOOR ELEVATION. MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, P8= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, P= UTILITY PO W F= WOOD F R = RADIAL t KHOV JOHN R.BEACH&ASSOCIATES,INC. Drawn 0Y SMS Square Feet: 15113.83 t SURVEYORS AND MAPPERS Checked By 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY Scale: (813) 854-1276 FAX (813) 855-8370 1"=30' NOT VALID WITHOUT THE SIGNATURE AND :°PL4TvI5Y•AN 9/9/08 JBS � �1 THE ORIGINAL RAISED SEAL OF A FLORIDA I H R. BEACH DATE LICENSED SURVEYOR AND MAPPER FLORI REG. LAND SURVEYOR No. 2984 LB#4493 Revisions: • & 72 /c76 PERMIT APPLICATION DRIVEWAY PERMIT APPLICATION CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY All information must be filled-in completely City of Zephyrhills 5335 8"'Street, Zephyrhills, FL 33542 Telephone 813.780.0000 Fax 813.780.0005 PROJECT JOB SITE: PROPERTY OWNER Address: D Name: Windward Homes Unit#: ,S Address: i Parcel Identification Number: City, State, Zip 4-26-21—0060- OOIUO - OCU Phone: Fax: 813-425-8706 CONTRACTOR: Company: WI nr3warr3 Nnmas Name: Paul M. Gregory Contractor's License #: CRC5O241 E-Mail: c ra ey@khov.com — Phone:813-885-7744 Cell: Fax: 813-425-8706 ARCHITECT/ENGINEER: Name:Pearman/Berger/Carotti Firm Name: Whetstone jai nr�ari nTR Testing Address: 2004 rr3 Ay East Ci y:Brar3entrn State: Zip: State License#: 44099/64003/64764 PhoneA41 7 7 11.3£I Cell: Fax: Description of Project a5'6" TYPE OF DRIVEWAY LENGTH OF DRIVEWAY CULVERTS NEEDED RESIDENTIAL DRIVEWAY tiWIDTH OF DRIVEWAY ( )REINFORCED CONCRETE COMMERCIAL DRIVEWAY R.O.W. EXCAVATION ( )CORRUGATED MATERIAL PUBLIC ACCESS DRIVEWAY -DEPTH LINEAR FEET ( )BOX CULVERT ( )OTHER(EXPLAIN) CONSTRUCTION MATERIAL CURB CUT REQUIRED ASPHALT YES NO _CONCRETE HEADWALL EOUIRED? YES NO NOTICE TO APPLICANT: If actual work exceeds scope of this description,additional permits or drawings' will be required. UTILITY LOCATIONS EO R D: CALL BEFORE YOU DIG: 1.800.432.4770 Page lot 3 PERMIT APPLICATION OFFICE USE ONLY 1Irll Concrete (min. 6") Y N �ct,(u, we-,&i Qt(, T-0F_ Asphalt Base (min. 6") Y N Asphalt(min. 1½") Y N Length (min. 19') Y N c Width (10'min—20'max) N Existing sidewalk. Y New sidewalk. y N M4PL1 ADA compliant. Y N Expansion material required. Y N Contiguous parking pad. Y N Triangular flare (3'W x 7'L) Y N Visibility triangle o.k.? N Side set back(3'min. R.O.W.) N Plan Review Fee Permit application approved by. Date: 2—� Page 3 of 3 r� PLOT PLAN SEC. 04 , TWP. 26 S, RNG. 21E. LOT 5, BLOCK i SKETCH ONLY NOT A BOUNDARY SURVEY IB1ING BASIS: SILVERADO - PHASE 1A NORTHERLY LOT LINE OF LOT 5.BLOCK 1 BEING N 89'44'00"E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: INI TITLE SEARCH. ALSO SUBJECT TO SETBACKS. THIS PLAN IS FOR PERMITTING PURPOIES EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. p UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND'UTILITIES ARE NOT LOCATED OR LEGEND: a SHOWN. PROPOSED DRAINAGE FLOW V DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00)— = PROPOSED GRADE w� NOTES TAKE PREFERENCE. E-00.00 EXISTING GRADE .0 DESCRIPTION FLAT NOTES: - PAGE INDICATESCONTHAT PLAT BOOKAND IS IN LOT GRADING TYPE - A PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION 98.90' CHANGE AND/OR REVISION. FRONT SETBACK — 20' SIDE SETBACK 5' CERTAIN DATA SHOWN HEREON BASED ON REAR SETBACK= 15' ENGINEERING PLANS PROVIDED BY CIJENT. TRACT 107 STRUCTURE TIES SHOWN HEREON DENOTES ZHCCL,P.B.I.PACE 55 MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. = 10'UTILITY EASEMENT 10 LANDSCAPE BUFFER/WALL EASEMENT 4,�E°Bs N 89'44'00" E 163.93' _G. l PLAT a 0 t 0 BOUNDARY ______ ________________ Np CE,.. 1g010 :�, (310)O m C `I O f1 •N U IY 37.55' A/ N Z \ A I O� o SAN BLOCK 1 0 4p 0,9 TI ^ 16b o � oR� kph .. C 3.12' LOT 6 l ( BLOCK 1 o gC ri n: 7600, TOTAL LOT - 15113.83 sO. FT. TOTAL SOD AREA - 12484 50. FT. DELTA GOLD + H CONC AREA = 766 SO. FT. COURT , - _2372 S0. FT. (0.R.7289,PG.1224) $ _ q LOT OCCUPIED SETTLERS COURT(PLAT) m NOTE: CONC AREA NOT UNDER ROOF !/n1(R/W�RIES) PCP((P)) RADIUS C PROPOSED LOWEST FLOOR ELEVATIONS: I CURVE RADIUS ARC DELTA ANGLE CHORD BEARING -LIVING AREA: 99.20' I C19 52.00' 44.66' 49'1246 43.30 N 6539'37'W GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO LOT 5, BLOCK 1, MAP OR PLAT ENTITLED "SILVERADO - PHASE NATIONAL GEODETIC VERTICAL IIA', AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75, DATUM OF 1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0298 D EFFECTIVE DATE: 9/30/92 EGEND: (C)— CALCULATED DATA. (D)= DEED DATA, (M)= MEASURED DATA, (P)— PLAT DATA. E- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB. C/S= CONCRETE SLAB. CH— CHORD, CHB— CHORD BEARING,CLF— CHAIN LINK FENCE. CONC- CONCRETE, COV.- COVERED.E/P- EDGE OF PAVEMENT. ESM'T— EASEMENT, /C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP- FOUND IRON PIPE, FIR= FOUND IRON ROD. FN&D= FOUND NAIL&DISK, FPP. FOUND PINCHED IPE. LFE= LOWEST FLOOR ELEVATION, HAS.- MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT EFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2'IRON ROD&CAP No. 4493, SN&D= SET NAIL&DISK, TBM- TEMPORARY BENCHMARK. I/P.. UT1UTY POLE. WJF— _ RADIAL JOHN R.BEACH&ASSOCIATES,INC. fOW,, y SMS Square Feet: 15117 03 t KHOV SURVEYORS AND MAPPERS Checked By. 911 WEST ST. PETERSBURG DRIVE AB ONE OLDSMAR, FLORIDA 34577 WAY Sc5le: (813)854-1276 FAX(813) 855-8370 1"-30' cp t o NOT VALID WITHOUT THE SIGNATURE AND :obLSfT"PYAN 9/9/OR JBS ` THE ORIGINAL RAISED SEAL OF A FLORIDA H R. BEACH DATE LICENSED SURVEYOR AND MAPPER FLORI REG. LAND SURVEYOR No. 2584 LB 4493 Rviions: PERMIT APPLICATION UTILITIES LOCATE CONFIRMATION NUMBER: PROVIDE SKETCH IN THIS AREA, IF ADDITIONAL SPACE IS REQUIRED, ATTACH TO THIS APPLICATION. ky" of AFFIDAVIT: Application is hereby made to obtain a permit to do work and installations as indicated. I certify that all foregoing information is accurate and that all work will comply with all applicable codes. I understand these codes shall take precedence over all approved construction documents,and issuance of this permit is verification that I will notify the property owner of Florida Lien Law req.,F.S.713. The issuance of this permit does not ensure compliance with deed restrictions and I understand that additional deed restrictions may apply to this property. All work shall comply with the current Florida Building Code,Public Works Design Manual and FDOT Design Standards(if applicable). (Public Works Design Manual online link: www.ci.zephyrhills.fl.us/public_works.asp) APPLICATION IS VOID UNLESS SIGNED WITH PROPER IDENTIFICATION AND WITNESSED BY A PERMIT TECHNICIAN OR NOTARY PUBLIC. NOTE: The City of Zephyrhilis is not responsible for maintenance or repairs of driveways. Driveways shall not alter/ interfere with existing stormwater treatment and/or conveyance. PROPERTY OW�IFS: By signing this applic on. I certify that I have read and understand the owner/builder disclosure n ent. (-a (please initial) CDV0-) . Applicant Print Name pp scant Signature Date Permit Technician Signature (or)Notary Signature Date Applicant is( ) personally known to me or produced as identification. (type of identification) Page 2 of 3 FEE SHEET COMM RES Square Feet: 0 Rate Computed At: _ Valuation: c I ]c f d1I (Use System Calc for Fees) Radon: a a Connection Fees: Sewer: Water: Water Meter: Size Current 6/11/07 3/" 180.00 220.00 All Residentials 1" 250.00 320.00 1 .5" 650.00 725.00 2" 875.00 990.00 3" & 4" Contact Louie for Quote Irrigation Connection: 175.00 266.00 Plus Meter Charge Above Based on size Impact Fees: School: _ Transportation. Park: e Public Safety: Z.7-) o ) City of Zephyrhills, Florida Page 1 of 2 Welcome to �.�.. ti Residential Permitting Checklist ADMINISTRATION CITY COUNCIL RESIDENTIAL POLICE DEPT CHECKLIST FOR NEW CONSTRUCTION PERMITTING FIRE DEPT City of Zephyrhills Building Department LIBRARY 5335 8th Street Zephyrhills , FL 33542 AIRPORT UT-I ITIES Application completed in its ENTIRETY. )I PUBLIC WORKS Notice of Commencement certified copy BUUILBING DEPT Check if contractors and subs are currently registered. DEVELOPMENT SEBOPME �-ficL��orm Florida Ener completed J PARKS a RECREATION Plot Plan. PURCHASING Property Survey. DEPOT MUSEUM VISITORTWO SETS of Engineered Building Prints with electrical, plumbing INFORMATION & mechanical diagrams Homeowner, check for proper "Homeowner's Affidavit" form. //Subdivision Design Review Compliance Letter ✓/ R-O-W Use Permit Give Elevation Certificate, if applicable. Verify Water & Sewer Service. Annual Solid Waste Assessment Fee must be paid to Pasco County Building Department prior to issuance of Certificate of Occupancy. STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 1940 NORTH MONROE STREET •a'o•..+ ' TALLAHASSEE FL 32399-0783 GREGORY, PAUL MICHAEL WINDWARD HOMES 8803 RIVERLACHEN WAY RIVERVIEW FL 33578-4966 STATE OF FLORIDA Congratulations! With this license you become one of the nearly one million DEPAR jr Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers,from boxers to barbeque restaurants,and they keep Florida's economy strong. >� } � Every day we work to improve the way we do business in order to serve you better. � �;; ;' , ;. , ,: � „ .r� log y For information about our services,please onto www.myflorldalicense.com. _ There you can find more information about our divisions and the regulations thatk - r� impact you,subscribe to department newsletters and learn more about the iWINDWARD Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly.We constantly strive to serve you better so that you can serve your customers. CERTI, , l Thank you for doing business in Florida,and congratulations on your new license! = dS, AUG 3 , Loe82zo3.445 DETACH HERE AC# 3938101 8O822445 08/22/2008 The RESIDENTIAL CONTRACTOR Named below IS CERTIFIED Under the proviians otC Expiration dates AUG GREGORY, PAUL _ `r MICHAEL WINDWARD a CENTER" BLVD SUITE 50 TAMPA FL 3364 CHARLIE CtIT CH W. DRAGO ARLES GOVERNOR D BY LAW .A -- •�v.. ..�1 J 11'IL. t_tjJJJJJJV� �Q 1 ; °94258778 P.i Notice of Preventative Treatments for Subterranean Termites (As required by Florida Building Code(FBC)104.2.6) TRI-S Pest Control Service 802 W.Waters Avenue Florida 33604-2946 3 LD 3 of 1p Address of treatment or Lo'Block of Treatment Date BORA-C.A_RE Termitjcjde(Wood Treatrnent) Product Used Disodium Octaborate Tetrahydrate 23%Active Ingredient Chemical used(active ingredient) Percent Concentration Aoolication will be oer[ormed onto structural wood at dried in era ge of cons1nIcLj Stage of treatment(Hon2ontal,Vertical,Adjoining Slab,retreat of disturbed area) BORA-CARE terrniticide applicatjon shall be applied accordin to EPA registered label directions as stated in the Florida Building Code Section 1816.1.8. (INFORMATION TO BE PROVIDED TO LOCAL BUILDING CODE OFFICES PRIOR TO CONCRETE FOUNDATION INSTALLATION _ _, L71 Sy 5557h4 TO:94258778 P.2 Notice of Intent For Preventative Treatme (as required by Florida Building Code nts for Termites ., 8 (FBC)100.2.67 Tri-S Pest Control Service 802 W.Waters Avenue Tampa,Florida)33604-2946 Phone:(813)936-S8S0 (Address of Treatment or Lot/Block of Treatment) th Qi Date BORA- w u mit1cide (WooT d ..e,... t Product'Wea - ••`nt Diso—di——Tn-pcta�+mte Tetrahvdrat. �3%Active 7n redi nt Chemical used(active Ingredient) Percent Cdneentratton ilcation will erformed on o stru oral' nod a dri -in stn e of construction Stage of treatment(Horizontal,Vertical,Adjoining f g Slab,retreat of disturbed area) toted I %gh Terrnitici e,a iicatio shall b:e lied accordin to EPA re istered Label di c as fated iri`the Florida Buildin Code Section 1816.1x3.(1NFO 77ON.TO$E PROVIDED TO LOCAL BL]L])MG CODE OFIq CONCRETE FOUNDATION INSTALLATION) _ CES PRIOR TO PERMIT APPLICATION DRIVEWAY PERMIT APPLICATION CONSTRUCTION WITHIN PUBLIC RIGHT-OF-WAY All information must be filled-in completely City of Zephyrhills 5335 8"Street, Zephyrhills, FL 33542 Telephone 813.780.0000 Fax 813.780.0005 m'-I ydufldfng[epatWents s e Faux � � flCdpy to Public Works PROJECT JOB SITE: PROPERTY OWNER Address: D Name: Windward Homes Unit#: ,5" Address: i Parcel Identification Number: City, State, Zip 4-26-21—0060- cblno - oocb Phone: Fax: 813-425-8706 CONTRACTOR: Company: WI ndward I-Irampa Name: Paul M. Gregory Contractor's License #: CRC5O241 E-Mail: cbradley@khov.com Phone:813-885-7744 Cell: Fax: 813-425-8706 ARCHITECT/ENGINEER: Name:Pearman/Berger/Carotti Firm Name: Address: 2004 rrl Aycniic Fact City• .adenton State: r6 Zip: 347n� State License#: 44099/64003/64764 Phone941 7 7 11 fi Cell: Fax: Description of Project a5-6•a TYPE OF DRIVEWAY LENGTH OF DRIVEWAY CULVERTS NEEDED _X RESIDENTIAL DRIVEWAY tWIDTH OF DRIVEWAY ( )REINFORCED CONCRETE COMMERCIAL DRIVEWAY R.O.W. EXCAVATION ( )CORRUGATED MATERIAL PUBLIC ACCESS DRIVEWAY ti�-DEPTH LINEAR FEET ( )BOX CULVERT ( )OTHER(EXPLAIN) CONSTRUCTION MATERIAL CURB CUTREQUIRED ASPHALT YES NO _. CONCRETE HEADWALL R EA IR D? YES NO NOTICE TO APPLICANT: If actual work exceeds scope of this description,additional permits or drawings will be required. UTILITY LOCATIONS REQUIRED: CALL BEFORE YOU DIG: 1.800.432.4770 Page 1 of 3 PERMIT APPLICATION UTILITIES LOCATE CONFIRMATION NUMBER: PROVIDE SKETCH IN THIS AREA, IF ADDITIONAL SPACE IS REQUIRED, ATTACH TO THIS APPLICATION. oJ AFFIDAVIT: Application is hereby made to obtain a permit to do work and installations as indicated. I certify that all foregoing information is accurate and that all work will comply with all applicable codes. I understand these codes shall take precedence over all approved construction documents,and issuance of this permit is verification that I will notify the property owner of Florida Lien Law req.,F.S.713. The issuance of this permit does not ensure compliance with deed restrictions and I understand that additional deed restrictions may apply to this property. All work shall comply with the current Florida Building Code, Public Works Design Manual and FDOT Design Standards(if applicable). (Public Works Design Manual online link: www.d.zephyrhills.fl.us/public_works.asp) APPLICATION IS VOID UNLESS SIGNED WITH PROPER IDENTIFICATION AND WITNESSED BY A PERMIT TECHNICIAN OR NOTARY PUBLIC. NOTE: The City of Zephyrhilis is not responsible for maintenance or repairs of driveways. Driveways shall not alter/ interfere with existing stormwater treatment and/or conveyance. PROPERTY OW) : By signing this appli on. I certify that I have read and understand the owner/builder disclosure tement. (i11((—" (please initial) Applicant Print Name pp scant Signature Date Permit Technician Signature (or)Notary Signature Date Applicant is( ) personally known to me or produced as identification. (type of identification) Page 2 of 3 PERMIT APPLICATION OFFICE USE ONLY Concrete (mm . 6") Y N Asphalt Base (min. 6") Y N Asphalt(min. 11/2") Y N Length (min. 19') Y N Width (10'min— 20'max) Y N Existing sidewalk. Y N New sidewalk. Y N ADA compliant. Y N Expansion material required. Y N Contiguous parking pad. Y N Triangular flare (3W x 7'L) Y N Visibility triangle o.k.? Y N Side set back(3'min. R.O.W.) Y N Plan Review Fee Permit application approved by: Date: Page 3 of 3 LOT PLOT PLAN SEC. 04 , TWP. 26 S, RNG. 21E. 5, BLOCK 1 SKETCH ONLY SIL 5, O - PHASE 1A NOT A BOUNDARY SURVEY BEARING BASIS: PASCO COUNTY, FLORIDA. NORTHERLY LOT LINE OF LOT 5, BLOCK 1 BEING N 8944'00" E THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRAWING: MAY BE DISCLOSED BY A FULL AND ACCURATE THIS PLAN IS FOR PERMITTING PURPOSES 1T TITLE SEARCH. ALSO SUBJECT TO SETBACKS, EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. b UNDERGROUND FOOTER, STEM WALL, AND UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: a SHOWN. _i--+ = PROPOSED DRAINAGE FLOW (00.00)— = PROPOSED GRADE DO NOT SCALE THIS PRINT. DIMENSIONS AND w NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE a NOTES: N_ DESCRIPTION NOT CONTAINING PLAT BOOK AND LOT GRADING TYPE = A PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = 98.90 CHANGE AND/OR REVISION. FRONT SETBACK = 20' SIDE SETBACK = 5' CERTAIN DATA SHOWN HEREON BASED ON REAR SETBACK = 15' ENGINEERING PLANS PROVIDED BY CLIENT. TRACT 107 STRUCTURE TIES SHOWN HEREON DENOTES ZHCCI., P.8.1, PACE 55 MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. * = 10' UTILITY EASEMENT •• = 10' LANDSCAPE BUFFER/WALL EASEMENT �'rFBSO) N 8944'00" E 163.93' PLAT . ** �E� BOUNDARY - - - - - - - - - - - - - - - - - - - - - - - - - IVO �98Qpryp1 �p1 co CC O < cn _a�u5 N rrI aw N VIZ 37.55' +p8 a z 0 (qNq w '^I • o a BLOCK 1 O 4 ; 0 o9 0 Q Q ,# Co 13.12' LOT 6 BLOCK 1 n 0 .(� / ti- t'79a° (96.90) CP(P) �— TOTAL LOT AREA = 15113.83_SQ. FT. DE LTA GO LD \ TOTAL SOD AREA _J..li4..._SQ. FT. SQ. FT. COURT TOTAL CONC AREA `�61� HOUSE =_ 372 __SQ. FT. (O.(0.11.7289,7289, PG.1224) o�' e�q. LOT OCCUPIED =-- --r° o S `� — SETTLERS COURT(Pu1T)I ,_ NOTE: (R/W VARIES) CONC AREA NOT UNDER ROOF (Q ) PCP(P)J RADIUS POINT PROPOSED I CURVE I RADIUS ARC DELTA ANGLE I CHORD I BEARING LOWEST FLOOR ELEVATIONS: C19 52.00' 44.66' I 49'12'46 I 43.30' I N 653937" W LIVING AREA: 99.20' GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO LOT 5, BLOCK 1, MAP OR PLAT ENTITLED "SILVERADO - PHASE NATIONAL GEODETIC VERTICAL 1A", AS RECORDED IN PLAT BOOK 61, PAGES 71 THROUGH 75, DATUM OF 1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0298 D EFFECTIVE DATE: 9/30/92 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA. (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE. A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED IPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, P= UTILITY POLE. W/F= WOOD FENCE. (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By SMS Square Feet: 15113.83 f KHOV SURVEYORS AND MAPPERS Checked By. 1 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"-30' NOT VALID WITHOUT THE SIGNATURE AND :oI5L JTv AN 9/9/08 JBS THE ORIGINAL RAISED SEAL OF A FLORIDA H R. BEACH DATE LICENSED SURVEYOR AND MAPPER I FLORI REG. LAND SURVEYOR Nc,. 2984 LB#4493 Revisions: APR-21-2008 10:24 SIMPSON MECHANICAL 813 558 8578 P.03 FORM 60OA-20048 -tiuiyyvcaUtj%. Y FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: WW1697PIll-PALM ISLAND 11-1697 S.F. LIVING Builder: WINDWARD HOMES T ' Address: 3("3i`� 1 1I-t 6 td C,ao_€t— Permitting Office: Ct'1tf o Z—///s City, State: �Y�{(hti7 � 'k— 335—'.Er< Permit Number: 5j Z I Owner. ENERGY SMART HOME Jurisdiction Number: (p t I too O Climate Zone: Central r1. New construction or existing New _ 12- Cooling systems 2. Single family or multi-family Single family a. Central Unit Cap:36.0 kBtu/hr 3. Number of units,if rnuiti-family I SEER: 15.00 _,,, 4. Number of Bedrooms 4 b. N/A — 5. Is this a worst case'? Yes _ — 6. Conditioned floor area(flu) 1697 ft2 — c. N/A — 7. G1ass type'and area:(Label regd.by 13-104.4.5 if not default) — a, U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default)239.0 ft2 — a, Electric Heat Pump Cap;34.6 k8tu/hr — b. SHGC: ITSPF:9.00 (or Clear or Tint DEFAULT) 7b. ('tint)239.0 R3 _ b.N/A S. Floor types — a. Slab-On�Grade Edge Insulation R=0.0, 178.0(p)ft — e, N/A b,NIA e, N/A 14. Hot wager systems 9. Wall types a. Electric Resistance Cap:40.0 gallons a. Concrete.lot Insul,Exterior R=4.1, 1122.0 ft2 — EF:0,92 b. Fram€,Wood,Adjacent R=1 1,0,247.0 ft2 _ b. N/A _ c- N/A d, N/A c, Conservation credits e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types — DTIP-Dedicated heat pump) a. Under Attic R38.0, 1697.0 ft= 15. HVAC credits PT, — b. N/A _ (CF-Ceiling fan,CV-Cross ventilation, c, N/A H1^-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Llna. Ret:Unc, A14:Garage Sup,R=6.0, 150.0 ft M7_-C-Multiaone cooling, b• N/A MZ-H-Multixone heating) Glass/Floor Area: 0.14 Total as-built points: 22310 PASS Total base points: 23553 I hereby certify that the plans and specifications covered by Review of the plans and cø' sty, this calculation are in corn wi a Florida Ener specifications covered by this ø 6a Code. calculation indicates compliance I PREPARED BY: with the Florida Energy Code. a„� DATE:. -ar9 before construction is completed /� this building will be inspected for I hereby certify that wilding, as is in compliance compliance with Section 553.909 with the Florida En rgy de. Florida Statutes, f o0 ' OWNERIAGE T: UILDING OFF GIRL: DATE: q \l tz y6 DATE: �' 1 Predominant glass type, For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) APR-21-2008 10:24 SIMPSON MECHANICAL 813 558 8578 P.04 I-OHM bUUA-LUU4K � •...�,..- --�_- _ _ SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:! , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type1SC Ornt Len Hgt Area X SPM X SOF= Points. .18 1697.0 24.35 7438.0 1,Single,Tint W 1.0 6.0 48.0 47.90 0.97 2226.0' 2.Single,Tint N 8,0 0.0 8,0 24.46 0.72 141.0 3.Single,Tint S 9.5 9.0 72.0 39.84 0.56 1598.0 4.Single,Tint E 14.0 9.0 18.0 53.27 0.44 417.0 5.Single,Tint N 1.0 6,0 16.0 24.46 0.97 381.0, 6.Single,Tint N 0.5 12.0 32.0 24,46 1.00 780.0 7.Single,Tint E 1.0 5.0 13.0 53.27 0.95 858.0 8.Single,Tint E 1.0 6.0 16.0 53.27 0.97 825.0 9.Single,Tint S 1.0 6.0 16.0 39.84 0.94 601.0 Ae-Hullt Total 239-0 78270 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 247.0 0.70 172.9 1-Concrete,Int Insul, Exterior 4.1 1122-0 1.18 1324,0 Exterior 1122.0 1,90 2131.8 2. Frame,Wood,Adjacent 11.0 247.0 0.70 172.9 Base Total; 1369.0 2304.7 As-Built Total: 1369.0 1491:8 " \ DOOR TYPES Area X BSPM = Points Type Area X SPM = Points; Adjacent 18,0 1.60 28.8 1-Exterior Insulated 20.0 4.80 96-0 Exterior 20.0 4.80 96.0 2.Adjacent Wood 18.0 2.40 43.2, Base Total: 39.0 124.8 As-Built Total: 38.D 139.2 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1697.0 2.13 3614.6 1.Under Attic 38.0 1697.0 1,84 X 1.00 3122:5. Base Total: 1697.0 3614.6 As-Built Total: 1697.0 3122,5 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Paints. Slab 178.0(p) -31.8 -5660.4 1, Slab-On-Grade Edge Insulation 0.0 178.0(p -31.90 -587' .2 Raised 0.0 0.00 0.0 Base Total: -5660.4 As-Built Total: 178.0 -tiB79.1- INFILTRATION Area X BSPM = Points Area X SPM Points . ' 1697.0 14.31 24284,1 1697.0 14.31 24294,1 I:nergyGauge®DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5,2 APR-21-2008 19:24 SIMPSON MECHANICAL 813 558 8578 P.05 FORM 600A-2004R r-tiCtyYvdUgU%o+-r.�:c SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT# BASE AS-BUILT Summer Base Points: 32105.8 Summer As-Built Points: 30991.4 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 36000btu0,SEER/EFF(15.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 30991 1.00 (1.09 x 1.150 x 1.00) 0.227 0,950 8366.7 32105.8 0.3250 10434.4 30991.4 1.00 1.250 0.227 0.950 8366.7 ' , EnergyGauge'^"DCA Form 600A-20048 EnergyGauge®IFlaRES'2004R FLRCSB v4.5.2 APR-21-2008 10:24 SIMPSON MECHANICAL 813 558 8578 P.06 FORM 600A-20048 -r.v.� WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point . .18 1697.0 9.11 2783.0 1,Single,Tint W 1.0 6.0 48.0 13.80 1.00 663.0 2.Single,Tint N 8.0 8.0 8.0 15.38 0.99 121;d' 3.Single,Tint S 9.5 9.0 72.0 10.88 1.89 1478.11 4.Single,Tint E 14.0 9.0 16.0 13,04 1.24 291.0 5,Single,Tint N 1.0 6.0 16.0 15.38 1.00 245.0 6.Single,Tint N 0.5 12.0 32.0 15.38 1.00 491.0 7.Single,Tint E 1.0 5.0 13.0 13.04 1.01 171.0 S.Single,Tint E 1.0 6.0 16.0 13.04 1.01 210.0 '< 9.Single,Tint S 1.0 6.0 16.0 10.86 1.01 175.0 A5-Built Total- 239.0 3M!0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 247.0 1,80 444.6 1.Concrete, Int Insul, Exterior 4,1 1122.0 3.31 3708.2 Exterior 1122.0 2,00 2244.0 2. Frame,Wood,Adjacent 11.0 247.0 1.80 444.6 Base Total: 1369.0 2688.6 As-Built Total: 1369.0 41628 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 16.0 4.00 72.0 I. tenor Insulated 20.0 5.10 102.0 Exterior 20.0 5.10 102.0 2.Adjacent Wood 18,0 5,90 106.2 Base Total: 38.0 174.0 As-Built Total: 38.0 2062 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1697.0 0,64 1086.1 1.Under Attic 38,0 1697.0 0.55 X 1.00 933.4 Base Total: 1697.0 1086.1 As-Built Total: 1697.0 Q33 . FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points,' „ Slab 178.0(p) -1.9 -338.2 1.Slab-On-Grade Edge Insulation 0.0 176,0(p 2.50 445.0 Raised 0,0 0.00 0-0 Bass Total: -330.2 As-Built Total: 17810 446,0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1697.0 -0.28 -475.2 1697.0 -0.26 -475.2 EnergyGauge®DCA Form 600A-2004R EnergyGauget/FtaRES'2004R FLRCSS v4.5.2 APR-21-2008 18:24 SIMPSON MECHANICAL 813 558 8578 P.07 I-UKM UlJUK-1UU4K Ll1[11 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , ,, PERMIT#: BASE AS-BUILT Winter Base Points: 5918.3 Winter As-Built Points: 9109.2, Total Winter X System = Heating Total X Dap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x D$M x AHU) (sys 1:Electric Heat Pump 34600 btuh,EFF(9,0)Ducts:Unc(S),Une(R),Gar(AH),R6.0 9109,2 1,000 (1.078 x 1.160 x 1.00)0.379 0.950 4103.7 5918.3 0.5540 3278.7 9109.2 1.00 1.250 0.379 0.950 4103.7 . Ener9yGautTM DCA Form 600A-2004R EnergyGauge(/FtaRES'2004R FLRCSB X4.5.2 APR-21-2088 10:25 SIMPSON MECHANICAL 813 558 8578 P.08 FORM BOOR-2UU41� L1 II r -.,..,— WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2460.00 9840.0 40.0 0.92 4 1,00 2460,00 1.00 9840:0 As-Built Total: 9840.-,' CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total* Points Points Points Points Points Points Points Points 10434 3279 9840 23553 8367 4104 9840 22310 PASS y b EnergyGaugeT""DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 APR-21-2008 10:25 SIMPSON MECHANICAL 813 558 8578 P-09 FORM 600A-20048 Code Compliance Checklist . Residential Whole Building Performance Method A - Details PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST -_ __ - COMPONENTS SECTION_—_-_ REQUIREMENTS FOR EACH PRACTICE __.. CFt� C Exterior Windows&Doors 606.1.ABC.t-1— Maximum:.3 cfm/sq•A.window area;-5 cfm/sq•fk.door area. ..,.—_. ._ •--- Exterior&Adjacent Walls 606.1.ABC.1.2,1 Caulk.gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall: foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility penetrations; between wall panels&top/bottom plates:between walls and floor. EXCEPTION,Frame walls where a continuous infiltration barrier Is installed that extends from,and is sealed to,the foundationto the top plate:_____.._ .___--_. ___—_.. Floors 606.1.ABC.1.2,2 Penetratlonslopenings}116"sealed unless backed by truss or joint members, EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed --- -- to the perimeter,penetrations and seams. _ Ceilings 606,1,ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits. chimneys.cabinets sealed to continuous air barrier;gaps in gyp board&top plate: attic access. EXCEPTION:Frame ceilings where a continuous Infiltration barrier is installedthat is sealed at the perimeter, at penetrations•and seams. _•—_ Recessed Lighting Fixtures 606.1.ABC,1.2.4 Type 1C rated with no penetrations,sealed;or Type IC or non-IC rated, installed inside a sealed box with 112"clearance&3"from Insulation; or Type IC rated with<2.0 cfm from .. conditioned space tested. --__—.., -- --._..... .... Molt{story Hauser 60fi_1.ABC,1.2.5 Air Gsrrier on perimeter of floor cavity between floors __- Additional Infiltration regts 606.1,ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS„ ___—_., GICK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1,ABC:3.2. Switch or clearly marked clr 0 reaker(electric Or cutoff(ga must be provided.,Extomal or built-In heat trap required.,,...._-_- Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer.Gas spa S.pool heaters must have a minimum thermal efficiency of 180b- -- -- —. . Shower heads -_ _ 612.1 _ .._.__.Water flow must be restricted to no more than 2_5 etallons_per minute at 80 Psi G. - — Air Distribution Systems 610.1 !All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed, insulated,and Installed in accordance with the criterla of Section 610. Ducts in unconditioned attics: R-6 min_insulation. —_—.. ---HVAC Controls — 607.1_-_--_ Separate ready ccessible manual or automatic thermostat for each system - _.___, Insulation 604.1,602.1 Ceilings-Min. R-1 9, Common walls-Frame R-1 1 or CBS R-3 both sides. Common ceiling &floors R-11. EnergyGaugeT" DCA Form S00A-2004R EnergyGauge(P/FIaRES'2004R FLRCSB v4,5.2 APR-21-2888 10:25 SIMPSON MECHANICAL 813 558 8578 P.10 ENERGY PERFORMANCE LEVEL (EPL) � DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* 87.0 The higher the score,the more efficient the home, ENERGY SMART HOME, I. New construction or existing New — (2. Cooling systems 2. Single family or multi-family Single family — a. Cuttiral Unit Cap:36.0 k13tu/hr — 3. Number of units,if multi-family I — SEER: 15.00 4. Number of Bedrooms 4 — b.N/A — 5. Is this a worst case? Yes — 6. Conditioned floor area(ft') 1697 fl= — c. N/A 7. Glass typel and area:(Label regd.by 13-104.4,5 if not default) — a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Snglc Default)239.0 ft' — a. Electric Heat Pump Cap:34.6 kBtu/ltr — b, Sl-;GC: HSPF:9,00 (or Clear or Tint DEFAULT) 7b. (Tint)239.0 ft2 — b,N/A 8. Floor types , a. Slab-On-Grade Edge Insulation R=0.0, 178.0(p)ft — c. N/A b.N/A c. N/A — 14. Hot water systems 9 Wall types a. Electric Resistance Cap:40.0 gallons a. Concrete,Int Insul,Exterior R=4.1, 1122.0 tt2 EF:0.92 b. Frame,Wood,Adjacent R=11.0,247.0 ft' — b. N/A c. N/A — -- d. N/A — c. Conservation credits _ e. N/A — (HR-Heat recovery,Solar 10. Ceiling types DIP-Dedicated heat pump) a. Under Attic R=38.0, 1697.0 ft= _ 15. HVAC credits PT, b.N/A — (CC-Ceiling fan,CV-Cross ventilation. c N/A — IIF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup;Unc. Ret: Une, AH;Garage Sup.R''6.0, 150.0 fl — MZ-C-Multizone cooling, b. N/A MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building -1KE sTA � Construction thro h the above energy saving features which will be installed(or exceeded) o in this home ore 1 inspect' . ise, a new EPL Display Card will be completed based on instal ed Co a compliant fea F. " ' Builder Signatu a C1 Date:__ ° Address of New 1 Tome: Lt3O 1. ok l City/FL Gip: h *1L S GOp,t *NOTE' The home's estimated energy performance is only available through the FLARES computer program, This is not a Building Energy Rating. Ifyou r score is 80 or greater(or 86 for a US EPA/DOE EnergvStar7mdesignation), your home may qualify for energy efficiency mortgage(EEM) incentives iif you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Horline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucf edufor information and a list of cerr f ed.haters. For information about Florida's Energy Efficiency Code For Building Construction, c:onroct the Department of Cornrnurrity 4fjairs at 8ti0/487-1824. I Predominant glass type,For actual glass type and areas,see Summer&Winter Glass output on ages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) APR-21-2008 10:25 SIMPSON MECHANICAL 813 558 8578 P.11 Job: FALM,ISLAND II-1697... Load Short orm pate: 1011112007 wr� Entire House e,►:tr, TRH SIMPSON MECHANICAL For: WINDWARD HOMES • • Htg CIg Infiltration 40 92 Method Simplified Outside db(°F) Avera e Inside db(°F) 70 75 Construction quality 90 Design TD(°F) 30 17 Fireplaces Daily range o - L Inside humidity(1°) 50 50 Moisture difference(gr/lb) 26 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade Goodman Trade Goodman Model SSZ140361 Cond SSZ140361 Coil A5PF303616 -5 KW. Efficiency 9 HSPF Efficiency 15 EER Heating input Sensible cooling 25920 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10080 Btuh Temperature rise 26 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0,040 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.84 ROOM NAME Area Htg load d Gig load `tg AVF Clg AVF FOYER B1 2586 1339 104 62 DINING 160 3876 3105 155 143 KITCHEN 180 1931 2798 77 129 LIVING 278 6969 8916 279 411 POOL BATH 74 2698 1300 1O8 60 B.R. #2 137 1818 1670 73 77 B.R.#3 160 3360 2108 135 97 BR.#4 4 162 2180 1507 87 69 MASTER B,R. 201 4271 2899 171 134 MASTER CLOSET 64 57 97 2 4 MASTER BATH 143 127 218 5 10 HALLWAY 59 52 89 2 4 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ti vr-1gh'CSC]ft Rlght-Suite ResI entisi 6.0.107 RSR2991d 2008-Apr- 1 1001:57 Page 7 Z:1Tommy HVAC\WW1697PI ILJe.rcp talc-MJ8 Qrientatlon.5W APR-21-2008 10:25 t I IrJui r 813 558 8578 P. 12 1697 29923 26O47 1200 1200 Entire House 1559 9Q4 Other equip loads 26250 Equip. (M 0.97 RSM 5309 Latent cooling .• S S TOTALS 1687 31481 31559 1200 1200 Printout certified by ACCA to meet all requirements of Manual J 8th End. 2008-ApP21 10:0157 wrti htsOft RigM-Suite ResldenUal 6 0,107 RSR29818 P01C 2 P:1Tommy HVAC\WW1697PIIIJexrp Calc=MJ9 prlenwdon-SW TOTAL P. 12