Loading...
HomeMy WebLinkAbout08-8422 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8422 ANNUAL FIRE PROTECTION MAINTENANCE _> _ • ...E Permit Number: 8422 Address: 7809 GALL BLVD Permit Type: FIRE PROTECTION MAINTENANC E ZEPHYRHILLS, FL. Class of Work: FIRE-PROTECTION MAINTENANCE Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 34-25-21-0150-00000-0020 Improv. Cost: . Date Issued: 10/14/2008 Name: WHAT A BURGER Total Fees: 25.00 Address: 7809 GALL BLVD Amount Paid: 25.00 ZEPHYRHILLS, FL. 33542 Date Paid: 10/14/2008 Phone: Work Desc: FPM-SEMI SUPPRESSION- WHATABURGER# 876 DONE IN AUGUST a wte.rj rf aTc4QL1 FIRE PERMIT FEES 25.00 UU � FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMNT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." P IT OFFICER PERMIT EXPIRES IN 30 DAYS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 83-780-0020 City of Zephyrhills Fire ,l Fax-813-780-0021 • Permit Application Date Received f - Phone Contact for Permit J352 l 53.2 6 l Owner's Name VV /� t� Ele - &7 6 Owner's Phone Number 17/ 5 '023 Owner's Address Fee Simple Titleholder Name Titleholder Phone Number I Fee Simple Titleholder Address Job Address 7S0 9 e ' z .p cl R ILLS 3 3:S'71L1 Lot# Sub Division Parcel# 3" 62i*Gj5o c0000.Od.zO Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL yy emi ®n Other Sprinkler ❑ ❑ ❑ B Recreational Bum Fire Alarm O O ❑ I Sparklers Hood Cleaning � ❑ ❑ O II E Sprinkler System Installations Hood Suppression ❑ " ❑ J f Standpipes(Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle Fire Pumps Waste Tire Storage ANNUAL Fire Works Flammable Application-ANNUAL I Valuation of Project Fuel Tanks Other: Contractor Company E 1 C} ' I jy $WMrl•'y GO Signature Registered Y/N Fee Current Y/N Address 7 ;aj SCEaøj i 3$µ1Q License# 4V J15 I ELECTRICIAN Company Signature Registered Y/J'J Fee Current I Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current I Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Y/N Address I License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) -NOTICE OF:DEED RESTRICTIONS: The undersigned understands that this permit may subject',to-"deed'':restrictions which may be more restrictive than County regulations. The-undersigned assumes responsibility for:compliance-with any applicable deed restrictions. UNLICENSED 'CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired :a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations if the contractor is not licensed as required by law, both the owner and contractor may be cited-for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may:apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727-847- 8009. Furthermore, if the owner has hired:a contractor or contractors, he is advised to have -the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitledto permitting privileges in Pasco County. CONSTRUCTION.LIEN LAW(Chapter713, Florida Statutes,-as.amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may.be requested, in writing, from the Building Official, for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension: If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMM EMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEN T OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y URN E F COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTO Subscribed and sworn to(or affirmed)before me this b cribed nd swo t affirme ) efore.me this ` 1' CLC.tLL by by Who is/are personally known to me or has/have produced Who is personally no o me or as identification. Notary Public Notary Public Commission No. Commission No. L )h f5 1`1 Name of Notary typed,printed or stamped Name of Notary typeole� Notary Public,State of Florida My comm.exp. Oct. 22,2008 Comm. No. DO 521489 SPECIALTY ELECTRONIC SYSTEI I ,iNC_ EF0001046 3.5j!.567-59915 P.O. BOX 41 - DADE CITY, FLORIDA 33526 - FAX 352-521-6085 GAMEWELL FIRE ALARM SUBMITTAL FOR THE ALLIANCE CHURCH ZEPHYRHILLS, FLORIDA ACCESS CONTROL-BURGLAR ALARM-CCTV-FIRE ALARM-GATE OPERATORS Features • Compatible with Gamewell's 600 Series analog addressable control panels. Addressable Manual Pull Station Alarm • Field programmable. • Durable construction. • Compact design,blends with surroundings. • Recessed pull lever prevents accidental Description operation. Gamewell's MS-95 is an easily a Surface or semi-flush installation. recognized • manual pull station • Double action option. with the distinctive bulls-eye • Key reset option. design compatible with Gamewell's addressable 600 • Meets ADA requirements. Series Fire Alarm Control Panels • Visible status LED. (FACPs). The MS-95 is approved • Terminal block model available(MS-95T). to UL Standard 38 for manual stations, meets architectural requirements in all building Listings interiors, and is readily noticed in Listings and approvals below apply to the a fire emergency. The addressable basic MS-95(T).In some cases,certain MS-95 manual pull station with a modules may not be listed by certain rugged toggle switch design offers approval agencies,or listing maybe in exceptional resistance to acciden- process.Consult factory for latest listing tal alarms caused by vibration status. and sudden shock. The MS-95 can • UL Listed:file S281 be used for surface and semi-flush installations. • CSFM approved:file 7150.1288:148 Operations- The manual pull station is activated by pulling forward on the readily identified bulls-eye alarm lever labeled "PULL" in distinctive white letters. Once pulled, this lever locks in the alarm position and remains there until manually reset. To reset the alarm lever, the front cover of the pull station is released by turning the screw on the top of the cover or turning the key (on certain models). This unlocks the front cover which is then lowered. Once the front cover is lowered the toggle switch is reset. An optional breakglass rod may be used with all stations. The self-clearing design prevents jamming of the station and there is no danger to the operator from broken particles of glass. Space is provided within the station housing for storage of an additional replacement glass rod. The MS-95 connects directly to the analog addressable circuit via two wires. The electronic circuitry has been designed to transmit data that can be interpreted as three output operations: normal standby operation, alarm operation and trouble operation. In its standby mode of operation, the pull station's circuit monitor the switch for alarm conditions. A trouble condition occurs when the pull station is addressed by the control panel and either reports back a trouble response or does not respond at all. With the standard priority interrupt feature, the MS-95 will report its condition virtually instantaneously to Gamewell's FACP. Gamewelf'_.`�dk'_ A ISO-Year Tradition MS-95(T) CS-2053 06129/04 Page 1 of 4 A Honeywell Company Specifications Programming Standby current Programming of the MS-95 manual station address is accomplished by setting a single DIP switch easily accessible on the device's printed circuit 0.0005 A. board. All other programming is accomplished at the FACP. Alarm current 0.0015 A. Engineer's SpecifictionS Operating temperature The analog addressable manual pull station shall contain the electronic interface circuitry required for individual device identification, alarm 0°C to 49°C(32°F to 120°F). reporting and trouble supervision. It shall communicate to the main control panel via the analog addressable circuit. The single-action station Relative humidity shall consist of a die-cast aluminum housing fitted with a pull out lever 85%,non-condensing. which, when operated, locks in position after activating an alarm initiating contact. Material Die-cast aluminum. Finish Fire alarm red,smooth gloss enamel.Raised cast letters are highlighted.Target background for pull lever is white glossed enamel. Dimensions MS-95 4.625"(11.75 cm)high x 3.25"(8.26 cm) wide x 2.0"(5.08 cm)deep(from the backplate). MS-95T 4.625"(11.75 cm)high x 3.25"(8.26 cm) wide x 1.625"(4.13 cm)deep(from the backplate). MS-95 with key reset option 6.25"(15.88 cm)high x 3.25"(8.26 cm) wide x 2.0"(5.08 cm)deep(from backplate)with Cat 60 Key. Surface Backbox PIN 28762 4.625"(11.75 cm)high x 3.25"(8.26 cm) wide x 2.375"(6.03 cm)deep tapped for 314"conduit. Surface Backbox 71961 6.25"(15.88 cm)high x 3.0"(7.6 cm)wide x 3.25"(8.26 cm)deep. Page 2 of 4 MS-95(77 CS-2053 06/29/04 X P95 P Features • Compatible with Gamewell's 600 Series analog addressable control panels. Photoelectric Smoke Sensor • Fits 4.0"(10.16 cm),6.0"(15.24 cm),or 6.0"(15.24 cm)low-profile,ultra•low- profile E-Z fit bases. Description • Audible alarm sounder base. • Four-wire relay base. Gamewell's XP95-P analog address- able photoelectric sensor operates • Address is stored in the sensor base. with Gamewell's analog addressable • Address is set by XPert addressing card. Fire Alarm Control Panels . Two color status LED. (FACPs). The photoelectric sensor digitally transmits its address and • Infrared smoke sensing design. the chamber's analog values to the • Continuous communications. FACP for analysis. The photoelec- tric sensor is distinguished by the • Optional remote LED. clear status LED, which flashes red ' briefly when the device is polled and turns on continuously when the device is in alarm. Listings Listings and approvals below apply to the basic XP95-P.In some cases,certain operation modules may not be listed by certain The XP95-P photoelectric sensor constantly monitors its sensing chamber approval agencies,or listing may be in and its internal electronics. The results are then reported along with the process.Consult factory for latest listing status. unit's address through the integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke • UL Listed:file S1 195 chamber and infrared smoke sensing design. The infrared emitter gener- • MEA approved:file 149.99-E ates a burst of light every second, or in response to direct interrogation. In clean air, the photo diode receives no light from the emitter because of the arrangement of the chamber. When smoke enters the chamber, it scatters FM light from the emitter onto the photo diode receptor in proportion to smoke characteristics and density; as the smoke content in the chamber in- APPROVED creases, the signal from the photo diode receptor increases. This informa- tion is processed and conditioned by an on-board, advanced-technology ASIC and digitally transmitted to the FACP. Trouble and Alarm conditions of the XP95 sensors are actually determined at the control panel. The status information of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature, the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed alarm response for the specific device in alarm. When a sensor is in alarm, the integral LED in the sensor's housing will light continuously. The XP95-P photoelectric device is connected to a two-wire SLC carrying both data and a 17 to 28 VDC supply voltage, and is insensitive to loop connection polarity. A remote LED indicator may be connected. The device is compatible with point-or group-addressable relay and sounder bases. Gamewell i A 150-Year Tradition XP95-P CS-2054 06/21/04 Page 1 of 2 A Ho neywell Company Engineer's Specifications Specifications The contractor shall furnish and install, where indicated on the plans, Standby current photoelectric smoke sensors with one of the several addressable mounting 340pA. base options available. The combination sensor head and twist-lock mount- ing base shall be UL Listed and UL Listed as compatible with the Alarm LED current Gamewell 600 Series analog addressable fire alarm control panels. The base 0.00434 A. shall permit free interchange of sensor heads without requiring any addi- tional wiring or additional programming of the head or base. The smoke Remote alarm output sensor shall contain an integral LED that shall latch in when the unit goes 0.004 A @ 5 VDC. into alarm. RF suppression techniques shall be employed to minimize false Temperature range alarms. The photoelectric smoke sensor shall be Gamewell model XP95-P. 32°F to 140°F(0°C to 60°C). Ordering Information Relative humidity (non-condensing) 0%to 95%. XP95-P Photoelectric sensor, analog addressable Recommended spacing (55000-650). Meets the 30 ft.(9.1 m)spacing guidelines XP95-B6EZ 6.0" (15.24 cm) ultra-low-profile EZ-Fit mounting in NFPA 72 Chapter 2;however,this base with XPert card (45681-250). spacing is based on ideal conditions and to be used as a layout guide only.Appropriate XP95-B4 4.0"( 10.16 cm) mounting base with XPert address installation-specific engineering is required. ing card (45681-2101). XP95-B6 6.0" (15.24 cm) mounting base with XPert address ing Card (45681-225). XP95-B6LOW 6.0"(15.24 cm) low-profile mounting base with XPert addressing card (45681-234). XP95-B6R4 6.0" (15.24 cm) relay base (four-wire) with XPert addressing card. XP95-B6SNDR 6.0" (15.24 cm) mounting base with XPert address ing card and audible alarm sounder in the base. 71112 Additional blank XPert addressing cards. 30203 Remote LED (24 V) on single gang plate. Gamewe1 "1__..1d0"h�_A 150-Year Tradition A Honeywell Company The Gamewell Company 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 Specifications and wiring information are provided for information only and are www.gam ewell.com believed to be accurate. Gamewell assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring A Honeywell Company instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell. © 2004 Gamewell Page 2 of 2 XP95-P CS-2054 06/21/04 Ser"ies 95 BasesFeatures ddr Analog np c • Compatible with all Gamewell's 600 Series foranalog Addressable Sensors Baseo bones able clude:detectors. • Base options include: 4.0"(10.16 cm),6.0"(15.24 cm),or 6.0"(15.24 cm)low-profile&ultra-low- profile bases feature"one-way"fit with Description low insertion force. Gamewell's XP-95 Series bases 4.0"(10.16 cm)wire relay base with dry provide superior flexibility for the or independently powered contacts. installation of the XP95 family of Audible alarm sounder addressable detectors. Whether the bases controlled individually or by group. project requires a 4.0"( 10.16 cm), 6.0" (15.24 cm), low-profile, relay, or • Device address is stored in the sensor sounder base, the XP95 family has base. • a base to meet building aesthetics, • Address is set h y patented XPert constraints, retrofit limitations or addressing card. functional needs. The device ad- a Compatible with all Gamewell XP95 dress is held in the base, ensuring. protocol detection devices. that the device address will not be changed no matter how often a detector is replaced, and verifying a consis- ,tent match between device type and device address. Each XP95 analog 'addressable head is compatible with a wide variety of XP-95 bases, ranging from one-piece low-profile units to four-wire relay and sounder bases that ,can be controlled individually or as a group. The XP95 Series of detector 'bases has been designed to enable sensors to be plugged in with minimum Listlnns force and to have a"one-way-only"fit. Relay and sounder bases can be addressed and controlled individually or by group in response to sensor Listings and approvals below apply to the alarms. basic Series 95 Analog Addressable Sensor Bases.In some cases,certain modules may PLO g ramming not be listed by certain approval agencies, or listing may be in process.Consult factory The only programming required at the Series 95 sensors is address setting, for latest listing status. via the patented XPert addressing card. The card is inserted into the • UL Listed:file S1195. sensor base. When the sensor head is inserted into the base,the address is automatically relayed to the sensor. Changing the sensor does not require additional programming since the address remains on the XPert Card ,located in the base.All other sensor-specific programming is accomplished at.the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given loca- tions after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting bases will accept any of the Series 95 sensors. The bases have a wide interior diameter for ease of access to wires and terminals. The design of the base is such that the sensor will fit in one way only and that a simple clockwise motion (without force) is required to plug in the sensor. The mounting base will have provisions for the insertion of the XPert addressing card as a means for programming and maintaining the sensor's address. The XP95-B4 base (4.0" [10.16 cm]) will mount directly to a 3.5" (8.89 cm) octagonal box (Raco 110 or equal)or a 4" (10.16 cm) octagonal box(Raco 125 or equal) with a round cover/plaster ring (Raco 727 or equal).The other Series 95 bases (6.0" [15.24 cm]) will mount directly to a 3.5" (8.89 cm) octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) octagonal box(Raco 125 or equal); or to a 4.0"(10.16 cm) square backbox (Raco 190 or equal). Gamewell - A 1S0-Year Tradition Series 95 Bases CS-2048 07/15/04 Page 1 of 2 A Honeywell Company Engineer's Specifications Specifications The contractor shall furnish and install, as indicated on the plans, either 4" Standard dual-chamber ionization (Gamewell model XP95-I) or photoelectric Model:B4. (Gamewell model XP95-P) smoke sensors, analog addressable multisensor Alarm current:NIA. (XP95-M) or electronic thermal sensor (Gamewell model XP95-T) with one Standby current:NIA. of the several addressable mounting base options available. The combina- Relay rating:NIA. tion sensor head and twist-lock mounting base shall be UL Listed and UL Listed as compatible with the Gamewell 600 Series analog addressable fire Sounder level:NIA. alarm control panels. The base shall permit free interchange of sensor Captive terminals:Yes. heads without requiring any additional wiring or additional programming 6" Standard of the head or base. Model:66,B6EZ,B6Low. Wiring Diagram Alarm current:N!A. Standby current:NIA. Relay rating:NIA. • +a V tR ( i5\/' Captive terminals:Yes. Uamt U �x V ,� �, Relay 0 0 Model:B6RA. t Alarm current:0.0036 A. Standby current:2pA. Wiring schematic for XP95-64,XP95-B6,XP95-B6-EZ shown. Relay rating:0.04 A @ 125 VAC resistive Ordering Information loading. Sounder level:N1A. XP95=B4 4.0" (10.16 cm) mounting base with XPert addressing Captive terminals:Yes. card. Sounder XP95=36 6.0" (15.24cm) mounting base with XPert addressing Model:BBSNDR. card. Alarm current:0.030 A. XP95-B6LOW 6.0" (15.24 cm) low-profile mounting base with XPert. Standby current:2pA. addressing card. Relay rating-N 1A Sounder level:85 dB @10 ft.(3.048 m). XP95-B6R4 6.0" (15.24 cm) relay base (four-wire)with XPert address- Captive terminals:Yes. ing card. XP95-B6EZ 6.0"(15.24 cm) ultra-low-profile EZ-fit mounting base with XPert addressing card. XP95-B6SNDR 6.0"( 15.24 cm) mounting base with XPert addressing card and audible alarm sounder in the base (MB-SDR- XP95). 30203 Remote LED(24 VDC). Gamewel'i 71112 Additional Bbank XPert Q addressing cards. A ISO Year Tradition A Honeywell Company The Gamewell Company 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Phone: 203 48-7718 Specifications and wiring information are provided for information only and are Fax: 03-484-7 7118om believed to be accurate. Gamewell assumes no responsibility.for their use. Data and design are subject to change without notice. Installation and wiring A Honeywell instructions shipped with the product shall always be used for actual installation. Company For more information, contact Gamewell. ®2004 Gamewell Page 2 of 2 Series 95 Bases CS-2048 07/15/04 XP95-PDRDRA 95-IDI-.IDR p � Features Analog Addressable • Compatible withGamewell's600Series m analog addressable control panels. Duct Smoke Detectors • Interchangeable"Plug-in"Photoelectric or ionization heads. • Address is stored in the sensor base. De cription • Address is set by XPert addressing card. Gami well's analog addressable duct • Remote alarm LED option. amok detectors provide early • Two-wire supply-polarity insensitive detec ion of smoke and products of . comb stion present in air moving • Very low standby current. _______ throw h an HVAC duct. Fans, • LED alarm indication on sensor head. _________ blow sand complete systems may be sh t down or activated in fire •• Rugged steel backbox with clear plastic __________ alarm mode by the Fire Alarm cover. Contrpl Panel (FACP) in the event • Large terminal connection screws. of smoke detection. • No additional screens or filters to clean or ______ - replace. The Gamewell analog addressable duct smoke detectors may utilize either • Relay version available with optional remote interchangeable photoelectric or ionization sensor heads. The external test unit. alarm indication is a light-emitting diode (LED), easily visible through the • Three standard tube lengths available 2.5. housing.A manual reset switch is provided on the front of the sensor. or 5 or 1 Oft(0.762, 1.524,or 3.048 m). Duct smoke Detectors are also available wit auxiliary relay contacts. The relay requires two additional wires for power and will activate when the sensor reaches alarm levels.All wiring must comply with local codes and regulations. • XP95 Duct Smoke Detectors digitally trans. it their address and the Listings chamber's analog value to.the FACP for ana ysis. Listings and approvals below apply to the Air sampling is accomplished by two tubeswhich protrude into the duct. basic XP95-PDI-PDR,XP95-IDI-IDR.In An exhaust tube of one standard length (7.5" [19.05 cm]) is provided with some cases,certain modules may not be the sensor housing. Intake sampling tubes, hich must be ordered sepa- fisted by certain approval agencies,or listing rately, are supplied in three standard length : 2.5 5 or 10 feet (0.762, may be in process.Consult factory for 1.624, or 3.048 m), latest listing status. Installation Duct mounting is accomplished by the use of a template and four sheet FM metal screws, provided. The duct detectors a e compatible with the analog APPROVED loops on Gamewell's 600 Series Analog Addre sable Control Panels. Programming The only programming required for the XP9 Duct Smoke Sensors is address setting. This is accomplished throug the use of the XPert ad- dressing card which is inserted into the sens r base. When the sensor head is inserted into the base,the address is auto atically relayed to the sensor. Changing the sensor does not require additio al programming since the address remains on the XPert card located in the base.All other sensor- specific programming is accomplished at the ?ACP. Gamewelf A 15•-Year Tradition XP95-PD CS-2049 06/29/04 Page 1 of 2 A Honeywell Company Engineer's Specifications Specifications The contractor shall furnish and install, where indicated on the plan Ambient temperature analog addressable air duct smoke detectors. The sensors shall be lis ed by 32°F to 120°F(0°C to 49°C). Underwriters Laboratories per UL 268A and UL-Listed as compatibl with the Fire Alarm Control Panel(FACP). The sensors shall operate at air Humidity velocities from 300 to 4,000 feet (91.44 to 1219.20 m) per minute. Th 10%to 85%R.H. smoke sensor shall contain an integral LED that shall latch in when the Material unit goes into alarm, mounted at a 30° slant to provide a wide views g angle. 18 gauge steel backbox,clear plastic cover A manual reset/test switch shall be located on the front of the device The Dimensions housing shall contain a sensor base which will accept photoelectric of 10"H X 8.25"W X 2.25D(25.4cm H X ionization heads. All wiring must comply with local codes and regulal�tions. 21 cm W X5.7cm 0). The duct sensor housing shall have a metal chassis with a clear plastic Maximum net weight cover and complete mechanical installation may be performed witho t 4.0 lbs.(1.814 kg). removal of the cover. The duct smoke detector shall be Gamewell Mo lel XP95-ID(R) or XP95-PD(R) analog addressable duct smoke detector. Mounting Template and necessary hardware supplied. Ordering Information Radioactive element For Ionization versions only:Americium 241 XP95-ID Two-wire air duct, ionization smoke detector 24 VDC (RW- (0.9 micro-curies). AAN). Sensitivity XP95-PD Two-wire air duct, photoelectric smoke detector 24 C Factory set(ion):adjustable via the IF600 (RW-AAP). control panel(photoelectric). 30203-01 Remote LED alarm indicator (two VDC) used with P95- Air velocity PD and XP95-ID. 300 to 4,000 feet per minute. XP95-IDR Four-wire air duct, ionization smoke detector 24 VDO with Pressure differential relay (RW-ARN). 0.01 to 1.2 inches(1.524 to 20.320 XP95-PDR Four-wire air duct, photoelectric smoke detector 24 C meters per second)of water. with relay (RW-ARP). Standby current 30203 Remote LED alarm indicator (24 VDC) - used with re ay Photoelectric:340 p A;Ionization:280p versions A. 30007-02 Remote test station with alarm LED used with relay Alarm LED current versions. Photoelectric:4 mA;Ionization:2 mA. 70896-02 Sampling tube - 2.5 feet.(0.762 m). ! Remote alarm output range 70896-05 Sampling tube - 5 feet(1.524 m). 20 mA maximum;diode gated. 70896-10 Sampling tube - 10 feet(3.048 m). Relay Versions Only: XP95-1 Ionization sensor head (replacement). Relay contacts XP95-P Photoelectric sensor head (replacement). Two dry Form-C contacts. 72247 Duct detector enclosure (WP-1)(see data sheet CS-230 ). Relay contact ratings10 A @ 24 VDC resistive max. �� Operating voltage Gamewell" p 24VDC. A 1S0-Year Tradition Standby Current A Woneywau company 0.010 A @ 24 VDC. The Gamewell Company Alarm Current 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Specifications and wiring information are provided for information only and are Fax: 203-484-7118 believed to be accurate: Gam well assumes no responsibility for their use. www.gamewell.com Data and design g gn are subject to1 change without notice. Installation and wiring instructions shipped with the p duct shall always be used for actual installation. A Honeywell Company For more information, contact Gamewell. O 2004 Gamewell Page 2 of 2 XP95-PD CS-2049 06/29/04 • •ice'. • :i!•}8r•��•ili�i is! a•'Ps+ �s iii ai••a• •pit=}����i•Lit'��• Indoor Selectable #.:: �•�:• *� Output Speaker Strobes and Dual Voltage Evacuation Speakers jr: 1 The new SpectrAlert*Advance selectable output speaker strobes and dual evacuation speakers can reduce ground faults and allow faster installation. SPECTRAjert Features The SpectrAlert Advance Series of speakers and speaker strobes •Plug-in design is designed to reduce ground faults.The plug-in design allows the Installer to pre-wire mounting plates and dress the wires before •Protective cover isolates speaker components,reduces ground plugging in the speakers.The plastic cover prevents nicked wires by faults covering exposed speaker components. •Electrical compatibility with existing SpectrAlert products •Field selectable candela settings on wall and ceiling units: This design also allows faster installations with instant feedback to Standard:15,15/75,30,75,95,1.10,115 ensure that wiring is properly connected,rotary switches to select High:135,150,177,185 voltage and power settings,and 11 field selectable candela settings for wall and ceiling speaker strobes. •Shorting spring on mounting plate tests continuity before installation The low total harmonic distortion of the SP speaker offers high •Rotary switch simplifies field selection of speaker voltage(25 and fidelity sound output while the SPV speaker offers high volume 70.7 Vrms)and power settings(Y4,½,t and 2 watts) sound output for use in high ambient noise applications. •Universal mounting plate for wall-and ceiling-mount units SpectrAlert Advance makes installation easy Compatible with System Sensor synchronization protocol •Attach a universal mounting plate to a 4 x 4 x 21/s inch back box. •SP speakers offer high fidelity sound output Flush mount applications are achievable without the need for an •SPV speakers offer high volume sound output extension ring. •Connect the notification appliance circuit or speaker wiring to the •Automatic selection of 12 or 24 volt operation at 15 and 15/75 terminals on the mounting plate. candela •Attach the speaker or speaker strobe to the mounting plate by •No extension ring required inserting the product tabs into the mounting plate grooves.Rotate 'Ceiling and wall mount application the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a •Optional tamper resistantTorx head screw included catch until it is secured with a captured mounting screw. Agency Listings usun approved 54048 7320.1483701 10.08-! SpectrAlert Advance Speaker and Speaker Strobe Specifications SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4x 2'/8-inch back box A universal mounting plate shall be used for mounting ceiling and wall products The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance speaker strobes, when used with the Sync-Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120124 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Speaker strobes shall have field-selectable candela settings Including 15,15/75,30,75,95, 110,115,135,150,177,185. The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service The speaker shall have a frequency range of 400 to 4000 Hz and shall have an operating temperature between 32°F and 120°F.Speaker shall have power taps and voltage that are selected by rotary switches. The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power taps which are selected by rotary switch.The strobe shall comply with the NFPA72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service The module shall synchronize SpectrAlert strobes at 1 Hz The module shall mount to a 4n/%x 411/6 x 2'/s-Inch back boxThe module shall also control two StyleY(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. 32°F to 120°F(0°C to 49°C) 10 to 93%non-condensing 6.0 In Lx 5.0 in W x 4.7 In D(Including lens and speaker) 6.0 In Lx 5.0 In W x 4.9 In D(Including lens and speaker) 6.0 In Lx 5.0InWx2.8inD 6.0 In Lx 5.0inWx2.9InD 6.8 in Dia.x 4.7 in D(Including lens and speaker) 6.8 In Dia.x 4.8 in D(Including lens and speaker) 6.8 In Dia.x 2.8 In D 6.8 In Dia x2.9InD 25 Volts or 70.7 Volts(nominal) S0VDC 1 flash per second Regulated 12 VDC/FWR or regulated 24 DC/FWR 8 to 17.5 V(12 V nominal)or 16 to 33V(24V nominal) 9 to 17-S V(12 V nominal)or 17 to 33V(24V nominal) 400 to 4000 Hz /4,> ,1,2 watts AOS-0424-002 UL Current Draw Data 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 86 83 80 77 90 87 84 81 86 83 80 77 90 87 84 81 85 82 79 76 89 86 83 80 85 82 79 76 89 86 83 80 Dimensions 6.81' .971.96" 6.81" 97" 184" 2b3" 5.00" 60" 5.98" 5. 7 O5u424- 2 Surface Mounting 0 ® 0 0 0 0 0 0 0 Ordering Information for SpectrAlert'Advance Speakers and Speaker Strobes SPW SPA Speaker only SPWV SPRV Speaker only,High dB SPSW* SPSR* Speaker Strobe,Selectable Candela(15,15/75,30,75,95,110,115) SPSWH* SPSRH* Speaker Strobe,Selectable Candela,High cd(135,150,177,185) SPSWV* SPSRV* Speaker Strobe,Selectable Candela(15,15/75,30,75,95.110,115),High dB SPCW SPCR Speaker only SPCWV SPCRV Speaker only,High dB SPSCW* SPSCR Speaker Strobe,Selectable Candela(15,15/75,30,50,75,95,110,115) SPSCWH* SPSCRH Speaker Strobe,Selectable Candela,High cd(135,150,177,185) SPSCWV* SPSCRV Speaker Strobe,Selectable Candela(15,15/75,30,75,95,110,115),High dB SPSCWVH* SPSCRVH Speaker Strobe,Selectable Candela,High dB,High cd(135,150,177,185) RFPW REP 7 in x 95 in Retrofit Plate SPBBSCW SPBBSC Ceiling Mount Back Box Skirt SPBBSW SPBBS Wall Mount Back Box Skirt TRW TR Wall Mount Irim Ring TRCW TRC Ceiling Mount trim Ring *Add-P to model number for plain housing(no'FIRE'marking on the cover)e.g.SPSW-P O20°e "s`"�°` 3825 Ohio Avenue•SL Charles,IL 60174 Pm a, peclM1caWls shJearodwlge wYAwt nakeNYtrynmsmsamm br Phone:800-SENSOR2•Fax 630-377-6495 N°e"yam"�T'n"'"9w^."d ln+he *am6mIDsr . A05-O424-002.5/08•#1986