Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
08-8448
CITY OF ZEPHYRHILLS SCI^ 53(813)780-020 8448 FIRE SPRINKLER SYSTEM PERMIT Permit Number: 8448 Address: 38435 5TH AVE HISTORIC Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-15300-0120 Improv. Cost: 13,750.00 Date Issued: 10/27/2008 Name: PRICE, MARCUS S & MJ Total Fees: 210.00 Address: 38435 5TH AVE -HISTORIC Amount Paid: 210.00 ZEPHYRHILLS, FL. 33542 Date Paid: 10/27/2008 Phone: Work Desc: INSTALLATION OF FIRE SPRINKLER SYSTEM y.. COMMERICAL FIRE&COMMUNICATION: FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 110.00 FIRE SPRINKLER SYS 50.00 FIRE-PRESSURE TEST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRACTOR SIGNATURE I IC ER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 NOTICE OF COMMENCEMENT rlis Insshument Prepared By. 111111 VIII 1110 VIII VIII VIII VIII 11111 VIII VIII Il l 111 Name II ilhams 2008151511 Address 0510123t',A,ve N L MOLEJ,3377 ,' �Perunut No Rcpt: 1208806 1208806 Rec: 10.00 Tax Folio No 11/26 21fa0 flf 15310 2ty DS: 0.00 I T: 0.00 10/17/08 Dpty Clerk THE UNDERSIGNED hereby serer notice that tmproveuttents will be track to certain reel property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. I-Description of property(legal description): 11!2 121/ 101 5300/0 0 34355 'Ave. Zhwii11J . 33542 2-General description of improvements: - Install are 'tciclersystem 3.Owner Information ( a)Name and address: Price Marcus S&M 138544 3n°Ave. ephyrhills.FL33542 b)Name and address of fee simper titleholder(if other than owner) l,G c)Interest in property N/A N/A ntractor Information a)Name and address:. any McDonald of Conarnercial Fire& Co m o 65J0 125th Ave !•L0 I,.33773 b)Telephone No.; 727-530..452j Fax No.{Opt.} 7Z7 5.Surety Infbnnatioll -,— -53I-(13 . a)Name and address: JfA b)Amount of Bond: c)Telephone No.: Fax No. (Opt,) 6.Lendet a)Name and address. N/A 7- Identity of rson pe Phone No. within the State of Florida designated by owner upon whom notices or other docwnents maybe served: a)Name and address; Lariy MeDona1of Commercial ire&Cpmwicatipnsj 65]025th Ave N Ljo FL 3773 b)Telephone No.: 727-530-4521 Fax No. (Opt,) 727-53 1 596 8.1n addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: a)Name and address: Lan' McDonald of Commercial Fire&Commnjcaijo Inc 65 125s Aye NLargo FL 33773 b)Telephone No.:_ 727-530-4521 Fax No. (Opt,) 727-53 -0596 9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date 1$specified): WARNING TO OWNER:ANY PAYMENT'S MADE BY THE OWNER AFTER THE EXPIRATION OFTOE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 7 3PAtT I,SE ON 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR JMFOVEMEN1S TO YOUR]PROPERTY. 4 NOTICE OF COMMENCEMENT MUST BE RECORDED AND POS'T'ED O JOB SITE BEFO THE FIRST o m m (NST'ECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YO LENDER OR AN A RNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COM CEMEN NOTARY PUBLIC-J`[tJE L. r'LGRIDA m� 3TATEOFFLORIO4 James Hall :aul�rrY OH Pasco Commission#DD419502 O1€icer/lectar/hlanages (��? Expires: APR. 17, 2009 4 �� — � � F, Bonded Thru A:ia-r_'c Borth Co.,Inc. Print ame and Title ��•� (.0 flee fore tinsn ent was acknovrledg fore rile o e � N this 6 day of G C� h 20 y,by r as D^t r C e ✓ (type of authority,e.g,officer,trustee, i o attorney in fact)fur ' .._(name of oa b insttttment was executed). 'ersonally Knotvnn y OR Produced Identification Notary Signah p e� m ) Wy,Z rype of Identification Produced Name(print) M �+ CS r+C) r m ---ANTD-- derificatiou pursuant to Section 92.525,Florida Statutes.Under penalties of perjury,I declare that I have read the foregoing and that he facts stated in it are true to the best of my knowledge and.belief. oRMI9/NOCsvediao7 Siguattue Ot'Natursl Person Signing(In line#10.)Above 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 ''' �� Building Department t OateRecsivad PhonecontactforPennittlnU 727 530 4521 Owners Name PRICE MARCUS S&M:J Owner Phone Number Owners Address 38544 3rd AVENUE Owner Phone Number Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 38435 5th AVENUE LOTS SUBDMSION PARCELIDN 11-26-21-0010-15300-0120 (Ct'rAlrl®nealrrrlOrE11TY TAX NOTICE) WORK PROPOSED e NEW CONSTR a ADD/ALT SIGN O MOVE 0 DEMOLISH INSTALL REPAIR PROPOSED USE O SFR O COMM O OTHER TYPE OF CONSTRUCTION O BLOCK O FRAME O STEEL O OTHER DESCRIPTION OF WORK I PROVIDE/INSTALL NEW FIRE SPRINKLER SYSTEM BUILDING SIZE I SO FOOTAGE I HEIGHT BUILDING 1$ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL �($ AMP SERVICE Q PROGRESS ENERGY O W.R.E.C. El PLUMBING $ MECHANICAL Is 13,750 VALUATION OF MECHANICAL INSTALLATION FIRE SPRINKLER El GAS O ROOFING O SPECIALTY O OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA OYES ONO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N J FEE CURRENT I Y/N Address License# --� ELECTRICIAN COMPANY r- SIGNATURE I REGISTERED I Y) N J FEE CURRENT Y N Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y I N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N I FEE CURRENT I Y/N N Address License# OTHER COMPANY REGISTERED PCOMMERCIAL FCIAL E DICRE &T COMMUNICATIONS SIGNATURE Address 6510B 125th AVE N.,LARGO FL. 33773 15091100012004 Lcense# RESIDENTIAL Attach(2)Plot Plans:(2)sets of Building Plans:(1)set of Energy Forms:R-O-W Perms for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Storrrnvater Plans w/Sift Fence installed, Sanitary Facilities 51 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities 51 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. •"'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (ABC upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW • NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTiUTILIT1ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner,I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: i certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,WaterMfastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. • Department of Health & Rehabilitative Services/Environmental Health Unit-Weis, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone"A"in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for tots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs,wells,pools, al conditioning, gas,or other installations not specifically included in the application. A perm issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,after,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit Issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117. OWNER OR AGENT CONTRACTOR Subscribed and sworn ( met)before me this Subscribed and sworn affirmed)before me this SEPT.15thby SEAN GUTHRIE SEPT.15th by SEAN GDTENIE Who is/are personalty known to me or hastrave produced 'Afro is/are personalty known to me or has/have produced u / as identification. ® � as identification / /\. 11.sL�-Notary Public s 1�/ i ' ,I!2-f's a Notary Public Co �DD502186 DD502186 Commission Noo. of ed or stamped Name at Notary typed,printed or stamped ,g1N`r�°'F� KELLY K.WILLIAMS �d`r� v iCELl v tL WILL[AMS MY COMMISS►ON#DD502186 � MY COM)NrSSION#DD502186 �0fF�elQ LX PiRES: Dec.27,2009of�0lA EXPIRES: Dec.27,2009 (407)398-0153 Fionda Notary Service.com. (407)398-0153 ;=londa Notary Service Corn • ZEPHYR ILL FIRE DEPARThE `T 6907 Dairy Road, Zephyrhiiis, FL 33542 ;-ire Chief Keifi, Williams us (81'3)780-0041 F x (813)f8e0-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: Contractor: QG Business Name: Billing Address: ! ' ! /t/ Business Address: Lob ,L 337?'4 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan WC Annual WC Sprinkler 1st Alarm WC Muni-Family/Commercial .06 sf let Re-inspection WC Standpipes 2nd Alarm WC (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200 0-25 Heeds violations corrected) Natural Gas $50 NON COMPIJANCE $150 26 plus Heads SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Underground $45 Sparkle $100 Per Riser $50 J Hydrostatic Test aysoum File Works $500 FIRE PUMP Acceptance Test perays*sm Camp Fire $25 Per Pump $100 U Hydrant Flow Controlled Bum $100 IRE ALARM SYSTEM Hood/Duct $50 Devices $50 FIRE ALARM SYSTEM Place of Assembly $50 Annual 26 plus Devices $100 System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS JJ Recall Acceptance $50 Flammable Application $50 Annual LI Wet $50 OTHER Waste Tae Storage $50 Annual Dry $50 Fire WaUsmoke Wan $15 per well Generator<KW $100 CO2 $50 LP Gas $25 pertank Generator>30 KW 150 Other $50 Natural Gas $25 per system Bin-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 fl Hood/Ducts $50 Tent 10'x10'or greeter $15 pent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Anna LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) Spray Booth $50 ❑Inspection scheduled DBL and cancelled less than 24 hours construction lnsp_ N/C /' U Emergency Vehicle A0 $50 FALSE ALARM PLANS TOTAL f Of- INSPECTION TOTAL[ PERMIT TOTAL[ TOTAL GRAND TOTAL 2/b _ I Comments: Date: l>D 22 ng InsCtor. �-r/r/ 41 r Zephyrhills Fire Rescue 6401 Dairy I oad,Zephyrhills,FL 33542 Fire 14arshal Bus(813)780-0041 Kerry Barnett Fax(813)780-0044 E-mail: kbamett@fire.zephyrhills.fl us Plan Review#: 08-133 Project: Goin' Postal Number of Pages: 1 plus calcs and spec package Date: October 22, 2008 The plans have been reviewed for the sprinkler installation located at 38435 5th Avenue and is allowed to move forward at this time. Paying for plans acknowledges the contractor agrees to the items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. System shall be compliant with NFPA 13,2007 edition. 2. System shall have a fire alarm system attached and monitored. 3. FDC shall be a 5"Storz turn down 4. FDC shall be marked and identifiable at night(reflective lettering on contrasting background-6"letters) 5. Provide no parking sign located by FDC. 6. Install sprinkler cabinet in accordance with the code. 7. Knox Box required. Application provided. Shall be mounted at front door at a height of 6'. Residential surface mount is sufficient. 2 Inspections to be completed: 1. Pressure Test 2. Acceptance Test(done in conjunction with fire alarm system) KERB BARNETT,FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. COMMERCIAL FIRE & COMMUNICATIONS INC. �� pO� P.O. Box 1350 LARGO, FL 33779 '(727) 530-4521 FAX (727) 531-0596 License #EF0000785 DATE 8 JOB NO.O ATTENTI ,p TOX1/1 f1 RE: eJ C� 54- \ WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items: ❑ Shop drawings 0 Prints 0 Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION SC&xp prit 3 ____ ± 9 pYscit brLtthJ. ' THESE ARE TRANSMITTED as checked below: 61"or approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ ❑ FOR BIDS DUE El PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: If enclosures are not as noted,kindly notify us at once. Q y S ..<„o Pr Yom. ��...I�:C+aS G FIRE 7''"i, } ^, 6907 Dairy Road, Zephyrhilis, FL 33i4 ire Chief Keil t Williams Th;s ( 'i 5''ai! ; 4 Vs (8i3)73 -0O FIRE SERVICE USER FEES Occupancy No.: Plan No.: Contractor. Business Name: Billing Address: ! ' f 4/ Business Address: �. __ Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 sm Plan N/C Ancal N/C SpirYder let Akan N/C 06 of let Re-inspection N/C Standpipes 2nd Alarm N/C (Minirnurn Charge$25.00 2nd Re•inapsciian $100 Fire Pump $50 3rd Alarm N/C 0 Ptan Re vision DEL 3rd Re.Inspedlon $250 Hoods $60 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $60 5th Alarm $150 SPRIMO.ER SYSTEMS (Suatoess closed until LP Gas $50 6th Alarm $200 0-25 Heads violations corrected) Nat"Gas $50 Noel oar .uwcs $150 26 plus Heads SPRINIQ,.ER SYSTEMS Fuel Ta die-per d* $50 STANDPIPE SYSTEM Hydro Undargra ds $45 Sparklers $100 ❑Per Riser $50iHydrantFlow Hydrostatic Test eyaem Fire Woks $600 FIRE PUMP Acceptance Teat persyeMm Canp Fire $25 ❑Per Pump $100 1j Controlled Bun $100 IRE ALARM SYSTEM HoodiDuct $50 25 Devices $50 FIRE ALARM SYSTEM Place o(As $50 26p&*Deices $100 0 System Acceptance $50 Fire Per, $25 SUPPRESSION SYSTEMS URood Ae $50 Hmurrsele Appaoalton $50 News Wet $50 OTHER aste The Storage $50 Newt Dry $50 Fire WeIRSmolas Wee $15 per wee Generator<KW $100 CO2 $50 LP Gas $25 pww* Generator>30 t4N 150 Other $60 Natural Gas $25 pereyriem Bto-Hwrd Waste $100 News MTCHE NEXHAUST' Funigalion Terrting $50 0 Hood/Duds $60 Tent 1(1x10 or greeter $15 petieru Torch Pot/Applied $50 OTHER Fire Pump $46 Haz.Makaids $100 Nmws LP babo(ion per to* $50 U Fire Suppression $30 Fuel Tank In taidion $50 System Acceptance (Per Tank) $50 8 Exhaust Hoodfbud $30 0 Nertsal Gas leahaeaan $50 Re*mpedian DEL (Per System) (other ihan annual) ❑Spray Booth $50 ❑iron acheduied DEL and canceled less then 24 hoes Corsarudlon leap. N/C Emergency Vehicle Acv $50 FALSE ALARM PLANS TOTAL- INSPECTION TOTAL[ � PERMIT TOTAL ^' TOTAL J1 GRAND TOTAL I J Comnwrsta: Date: / Commercial FIRE "" �"" Inc.� & Communications v ■r , 6510-8125'Avenue N. P.O. Box 1350 Phone(727)530-4521 Largo, FL 33773 Largo, FL 33779-1350 Fax(727)531-0596 Goin' Postal 38435 5' Avenue • Zephyrhills, Fl. 33542 Fire Protection System Description Manufacturer Part# Sidewall Sprinkler Tyco TY3331 Upright Sprinkler TY3131 Pendent Sprinkler TY3231 Check Valve Victaulic 717 Piping Allied Schedule 10 Schedule 40 Rigid Coupling Style 005 Hydraulic Calculations (Demand Only) ��ar�•Z�AQ�� key �`jJ Fu//Service Alarm&Communications Contractor License#EF0000785 • tqco Fire & Building Products Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Series TY-FRB — 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage ment provided by the Recessed Es- General cutcheon reduces the accuracy to which the fixed pipe nipples to the Description sprinklers must be cut. The Series TY-FRB, 5.6 K-Factor, Corrosion resistant coatings, where Horizontal and Vertical Sidewall Sprin- applicable, are utilized to extend the klers described in this data sheet are life of copper alloy sprinklers beyond quick response - standard coverage, that which would otherwise be ob- decorative 3 mm glass bulb type spray tamed when exposed to corrosive at- sprinklers designed for use in light and mospheres.Although corrosion resis- ordinary hazard,commercial occupan- taut coated sprinklers have passed the ties such as banks, hotels, shopping standard corrosion tests of the appli- malls, etc. They are designed for in- cable approval agencies,the testing is stallation along a wall or the side of a not representative of all possible cor- beam and just beneath a smooth cell- rosive atmospheres. Consequently, it ing.Sidewall sprinklers are commonly is recommended that the end user be used instead of pendent or upright consulted with respect to the suitability sprinklers due to aesthetics or building of these coatings for any given corro- _- construction considerations, where sive environment.The effects of ambi- piping across the ceiling is not desir- ent temperature, concentration of able. chemicals,and gaslchemical velocity, should be considered,as a minimum, The recessed version of the Series along with the corrosive nature of the TY-FRB Horizontal Sidewall Sprinkler chemical to which the sprinklers will be is intended for use in areas with a exposed. finished wall.It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch WARNINGS (12,7 mm) of recessed adjustment or The Series TY-FRB Sprinklers de- up to 314 inch(19,1 mm)of total adjust- scribed herein must be installed and ment from the flush sidewall position, maintained in compliance with this or a two-piece Style 20 Recessed Es- document,as well as with the applica- Technical cutcheon with 1/4 inch (6,4 mm) of ble standards of the National Fire Pro- recessed adjustment or up to 1/2 inch tection Association;in addition to the Data (12,7 mm)of total adjustment from the standards of any other authorities hay- flush sidewall position. The adjust- ing jurisdiction. Failure to do so may Approvals impair the performance of these be UL and C-UL Listed. • vices' FM,LPCB,and NYC Approved. The owner is responsible for maintain- (Refer to Table A for complete ap- ing their fire protection system and de- proval information including corrosion vices in proper operating condition, resistant status.) IMPORTANT The installing contractor or sprinkler Maximum Working Pressure Always refer to Technical Data manufacturer should be contacted Refer to Table B. Sheet TFP700 for the"INSTALLER with any questions. WARNING that provides cautions Discharge Coefficient with respect to handling and instal- / K=5.6 GPM/psil/2(80,6 LPM/bar1/2) lation of sprinkler systems and corn- Model/Sprinkler Temperature Ratings stallation can permanently damage Identification Refer to Table A. a sprinkler system or its compo- Finishes nents and cause the sprinkler to fail Numbers Sprinkler.Refer to Table A. to operate in a fire situation or cause Recessed Escutcheon:White Coated, it to operate prematurely. TY3331 - Horizontal Chrome Plated,or Brass Plated. TY3431 - Vertical Page 1 of 6 APRIL, 2006 • TFP176 Page 2 of 6 TFP176 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL CHROME WHITE"" LEAD LIQUID BRASS PLATED POLYESTER COATED 135"F/57°C Orange HORIZ. 155"F/68"C Red SIDEWALL 1,2,3,4,9,10 1,2,3,9 1,2,3.9 (TY3331) 175'F179"C Yellow 200"F/93"C Green 5.6 286"F/141"C Blue 1/2" NPT RECESSED 135"F/57°C Orange HORIZ. 155"F/68"C Red SIDEWALL 1,2,4,9,10 1,2,9 N/A (TY3331)° 175"F/79°C Yellow Figure 3 200"F/93"C Green RECESSED 135"F/57°C Orange SIDEWALL 155°Ff68'C Red 1,2.3,4,9 N/A (TY3331p+ 175"F/79°C Yellow Figure 4 200"F/93'C Green VERTICAL 135"F/57°C Orange SIDEWALL 155'F/68"C Red 5.6 (TY3431) 5,6,7,8,9 5,6 7,9 11Z- Installed 175Ft79 C Yellow NPT Pendent 200"F/93°C Green or Upright 286°F/141°C Blue NOTES: 1.Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 Inch(100 to 300 mm)top of deflector to ceiling distance. 2.Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 Inch(100 to 300 mm)top of deflector to ceiling distance. 4.Approved by the Loss Prevention Certification Board(LPCB Ref.No.007a/04)at a 4 to 6 Inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5.Listed by Underwriters Laboratories,Inc.as Quick Response Sprinklers for use In Light and Ordinary Hazard Occupancies. 6.Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use In Light Hazard Occupancies_ 8.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06&007a/04)as Quick Response Sprinklers. 9.Approved by the City of New York under MEA 354-01-E. 10.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11.Where Polyester Coated and Lead Coated Sprinklers are noted lobe UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon. Installed with Style 20(112"NPT)112'Total Adjustment Recessed Escutcheon. Frame and deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS l0 Physical Characteristics Operation E Frame . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper The glass Bulb contains a fluid which ~ Sealing Assembly . . . . . . . . . . 'i . Beryllium Nickel w/Teflont expands when exposed to heat.When Bulb . . . . . . . . . . . . . Glass the rated temperature is reached, the Compression Screw . . . . . Bronze fluid expands sufficiently to shatter the HSW Deflector . . . . . . . . Bronze glass Bulb, allowing the sprinkler to VSW Deflector . . . . . . . . Copper activate and water to flow. Patents U.S.A.5,810,263 . . . ._........._._.... • TFP176 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED HORIZONTAL SIDEWALL 250 PSI(17,2 BAR) (TY3331) OR 175 PSI(12,1 BAR) 175 PSI(12,1 BAR) 5.6 RECESSED HORIZ. 1/2" SIDEWALL(TY3331) (SEE NOTE 1) N/A NPT VERTICAL SIDEWALL (TY343i) 175 PSI(12,1 BAR) NOTES: 1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B,MAXIMUM WORKING PRESSURE Design * Temperature rating is DEFLECTOR Indicated on deflector or HAT 5 Criteria adjacent to orifice seat on frame. The Series TY-FRB Horizontal and **Pipe thread Vertical Sidewall Sprinklers are in- connections per ISO 7/1 tended for fire protection systems de- can be provided on signed in accordance with the stand- special request. and installation rules recognized by the 6* 4 2 3 1 applicable Listing or Approval agency (e.g., UL Listing is based on the re- 9/16" WRENCH 1/2"** quirements of NFPA 13, and FM Ap- (14,3 mm) FLATS NPT proval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon,as applicable,is to be used ® for recessed horizontal installations. 1-116" /16" (46,0 mm) (11,1 mm} CENTERLINE NOMINAL tI OF SPRINKLER MAKE-IN WATERWAY 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) 1- ramn 2-Butlon STYLE ESCUTCHEON 3-Sealing 10 or 20 — PLATE SEATING Assembly RECESSED SURFACE 4-Bulb ESCUTCHEON 5-Compression Screw 6-Deflector 2-7/8"DIA. (73,0 mm) FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL(7Y3331)SPRINKLERS Page 4 of 6 TFP176 Installation ARROW MUST POINTAWAY The Series TY-FRB Sprinklers must 7/16" FROMANDBE be installed in accordance with the fol- ESCUTCHEON (11,1 mm) PERPENDICULAR lowing instructions: PLATE SEATING ,,,, NOMINAL TO THE BACK SURFACE N T MAKE-IN WALL SURFACE NOTES Do not install any bulb type sprinkler if *6______ the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler 5 held horizontally, a small air bubble 2-3/16' 23/16" should be present.The diameter of the (55,6 mm) (55,6 mm) 4 air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 1.1/2^ WRENCH inch (2,4 mm) for the 286°F/141°C Iaim FLATS temperature ratings. 7 3 A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm).A maxi- SHOWN SHOWN CROSS mum of21 ft.lbs.(28,5 Nm)of torque PENDENT UPRIGHT SECTION may be used to install sprinklers with 1/2 NPT connections. Higherlevels of torque may distort the sprinkler and 1-Frame 3-Sealing 4-Bulb 6-Deflector cause leakage or impairment of the 2-Button Assembly 5-Compression 7-Ejection Spring Screw sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. plate by under-or over-tightening the **Pipe thread connections per iSO Ill can be provided on special request. sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 The Series TY-FRB Horizontal and 5.6 K-FACTOR.QUICK RESPONSE Vertical Sidewall Sprinklers must be SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS installed in accordance with the follow- ing instructions. Step 1.Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- Step B.After installing the Style 10 or Care and way perpendicular to the back wall and 20 Mounting Plate over the sprinkler parallel to the ceiling.The word"TOP" threads,hand tighten the sprinkler into Maintenance on the Deflector is to face towards the the sprinkler fitting. ceiling. Step C. Tighten the sprinkler into the The Series TY-BFR Sprinklers must Vertical sidewall sprinklers are to be sprinkler fitting using only the W-Type be maintained and serviced in accord- installed in the pendent or upright po- 7 Recessed Sprinkler Wrench (Ref. ance with the following instructions: sition with the arrow on the Deflector Figure 6).With reference to Figure 1, pointing away from the wall. the W-Type 7 Recessed Sprinkler NOTES Step 2.With pipe thread sealant ap- Wrench is to be applied to the sprinkler Before closing a tire protection system plied to the pipe threads,hand tighten wrench flats. main control valve for maintenance the sprinkler into the sprinkler fitting. Step D.After the ceiling has been in- work on the fire protection system that stalled or the finish coat has been ap- it controls, permission to shut down Step 3.Tighten the sprinkler into the plied,slide on the Style 10 or 20 do- the affected fire protection system sprinkler fitting using only the W-Type sure over the Series TY-FRB Sprinkler must be obtained from the proper 6 Sprinkler Wrench (Ref. Figure 5), and push the Closure over the Mount- authorities and all personnel who may With reference to Figure 1 or 2, the ing Plate until its flange comes in con- be affected by this action must be no- W-Type 6 Sprinkler Wrench is to be tact with the ceiling tiffed. applied to the wrench flats. The owner must assure that the spmn- The Series TY-FRB Recessed Hon- klers are not used for hanging of any zontal Sidewall Sprinklers must be objects; otherwise, non-operation in installed in accordance with the follow- the event of fire or inadvertent opera- ing instructions. tion may result. Step A. Recessed horizontal sidewall Absence of an escutcheon, which is sprinklers are to be installed in the used to cover a clearance hole, may horizontal position with their centerline delay the time to sprinkler operation in of waterway perpendicular to the back a fire situation. wall and parallel to the ceiling. The word'TOP'on the Deflector is to face Sprinklers that are found to be leaking towards the ceiling, or exhibiting visible signs of corrosion • TFP176 Page 5 of 6 5/881/4" (15,986,4 mm) FACE OF WRENCH RECESS MOUNTING SPRINKLER (END"A"USED FOR SURFACE FITTING 112"NPT MODELS) FIGURE 5 CLOSURE W-TYPE 6 SPRINKLER WRENCH 2-7/8"DIA SERIES (73,0 mm) WRENCH TV-FRB 2-1/4"DIA RECESS (57,2 mm) MOUNTING __________ PLATE 1/8" PUSH WRENCH (3,2 mm) IN TO ENSURE ENGAGEMENT 1-1/4"(31,8 mm) 3/4"(19,1 mm) WITH SPRINKLER 3/4"(19,1 mm) 114"(6,4 mm) WRENCHING AREA FIGURE 3 FIGURE 6 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER W-TYPE 7 RECESSED WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT SPRINKLER WRENCH STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" must be replaced. (12,7±3,2 mm) Automatic sprinklers must never be painted, plated, coated or otherwise FACE OF MOUNTING altered after leaving the factory.Modi- SURFACE SPRINKLERR-ITING fled sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion,but have not operated,should be replaced CLOSURE if they cannot be completely cleaned by wiping the sprinkler with a cloth or 2-7/8"DIA by brushing it with a.soft bristle brush. (73,0 mm) Care must be exercised to avoid dam- SERIESage to the sprinklers-before,during, TY-FRB 2-1/4"DIA- and after installation.Sprinklers dam- (57,2 mm) aged by dropping, striking, wrench twist/slippage,or the like,must be re- placed. Also, replace any sprinkler MOUNTING that has a cracked bulb or that has lost PLATE liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- 1/8" ommended to be initially performed for (3 2 mm) corrosion resistant coated sprinklers, after the installation has been corn- 1-1/4"(31,8 mm) 1/2"(12,7 mm) pleted,to verity the integrity of the cor- rosion resistant coating. Thereafter, 1"(25,4 mm) 114"(6,4 mm) annual inspections per NFPA 25 - should suffice;however,instead of in- FIGURE 4 specting from the floor level,a random SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER sampling of close-up visual inspec- WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT Lions should be made,so as to better STYLE 20 RECESSED ESCUTCHEON determine the exact sprinkler condi- tion and the long term integrity of the Page 6 of 6 TFP176 P/N 57 - XXX - X - XXX I I I SPRINKLER TEMPERATURE MODEUSIN RATING 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F/57'C 375 VERTICAL SIDEWALL TY3431 J 4 WHITE POLYESTER 155 155"F/68°C 3 WHITE RAL9010)' 175 175"F/19'C 9 CHROME PLATED 200 200'F/93°C 7 LEAD COATED 286 286'F/141°C TABLE C 'Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS corrosion resistant coating, as it may standards of any other Authorities Ordering be affected by the corrosive conditions Having Jurisdiction. Materials found present. by TFBP to be defective shall be either Procedure repaired or replaced, at TFBP's sole The owner is responsible for the in- option. TFBP neither assumes, nor spection,testing,and maintenance of authorizes any person to assume for it, When placing an order, indicate the their fire protection system and de- any other obligation in connection with full product name. Refer to the Price vices in compliance with this docu- the sale of products or parts of prod- List for complete listing of Part Num- ment, as well as with the applicable ucts.TFBP shall not be responsible for bere• standards of the National Fire Protec- sprinkler system design errors or inac- Contact your local distributor for avail- tion Association (e.g., NFPA 25), in curate or incomplete information sup- ability. addition to the standards of any other plied by Buyer or Buyer's repre- authorities having jurisdiction.The in- sentatives. Sprinkler Assemblies with NPT stalling contractor or sprinkler manu- In no event shall TFBP be liable, in Thread Connections: facturer should be contacted relative contract, tort, strict liability or under Specify: (Specify Model/$IN), Quick to any questions. any other legal theory, for incidental, Response,(specify K-factor),(specify It is recommended that automatic indirect,special or consequential dam- temperature rating), Series TY-FRB sprinkler systems be inspected, ages,including but not limited to labor (specify Horizontal Sidewall or Vertical tested, and maintained by a qualified charges, regardless of whether TFBP Sidewall)Sprinkler with (specify type Inspection Service in accordance with was informed about the possibility of of finish or coating),PIN(specify from local requirements and/or national such damages, and in no event shall Table C). codes. TFBP's liability exceed an amount equal to the sales price. Recessed Escutcheon: sed Limited Specify: Style w (10 ao 20)finish,P/N The fore warren is made in lieu Escutcheon with(specify') P/N of any and all other warranties. ax- • Warranty r imr>fted_inf warranties (S�pty of merchantability and fitness fora par- •Refer to Technical Data Sheet TFP770. Products manufactured by Tyco Fire& titular purpose. Building Products (TFBP) are war- This limited warranty sets forth the ex- Sprinkler Wrench: ranted solely to the original Buyer for clusive remedy for claims based on Specify:W-Type 6 Sprinkler Wrench, ten(10)years against defects in mate- failure of or defect in products,mated- P/N 56-000-6-387. rial and workmanship when paid for als or components,whether the claim Specify:W-Type 7 Sprinkler Wrench, and properly installed and maintained is made in contract,tort, strict liability P/N 56-850-4-001. under normal use and service. This or any other legal theory. warranty will expire ten (10) years from date of shipment by TFBP. No This warranty will apply to the full ex- warranty is given for products or corn- tent permitted by law.The invalidity,in ponents manufactured by companies whole or part, of any portion of this not affiliated by ownership with TFBP warranty will not affect the remainder. or for products and components which have been subject to misuse,improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 tqcoI Fire &.Building roduc Technical Services:Tel:(800)381-93121 Fax:(800)791-5500 Series TY-FRB — 2.8, 4.2, 56, and 8,0 K-factor Upright, Pendent, and..-Recessed Pendent Sprinklers Quick Response, Standard Coverage General mospheres.Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli Description cable approval agencies,the testing is not representative of all possible cor- The Series TY FRB,2.8,4.2,5.6,and rosive atmospheres. Consequently, it 8.0 K-factor, Upright and Pendent is recommended that the end user be Sprinklers described in.this data sheet = consulted with respect to the suitability are quick response -standard cover- of these coatings for any given cono- age,decorative 3 mm glass bulb type sive environment.The effects of-ambi- spray sprinklers designed for use in. ent temperature, concentration of light or ordinary hazard, commercial chemicals, and gas/chemical velocity, occupancies such as banks, hotels, should be considered,as a minimum, shopping malls,etc:` along with the corrosive nature of the The recessed version of the Series chemical to which the sprinklers will be TY FRB Pendent Sprinkler,where ap- exposed. plicable, is intended for use in areas An intermediate.level versions of the with a finished ceiling.It uses either a Senes-TY--FR_B Pendent Spnnktersare two-piece Style.10 (1/2 inch NPT) or detailed in Technical.Data.Sheet Style 40(3/4 inch NPT)Recessed Es- TFP356,and Sprinkler Guards are do- cutcheon with 1/2 inch (12,7 mm) of tailed in Technical Data Sheet TFP780 recessed adjustment or:up to 3/4 inch - _ (19,1 mm)of total adjustment from the WARNINGS flush pendent position,or a two-piece The.Series.TY-FRB. Sprinklers do- Style 20(1/2 inch NPT)or Style 30(3/4 scribed herein must be installed and inch NPT)Recessed Escutcheon with maintained in compliance with this 1/4 inch (6,4 mm)of recessed adjust- document,as well as with the applica- ment or up to 1/2 inch (12,7 mm) of ble standards of the National Fire Pro-total adjustment from the flush pen- section Association, in addition to the TY3231- Pendent 5.6K,1/2"NPT dent position.The adjustment provided standards o€any otherauthoritioshav- TY4 TY4231 - Upright 8.O4"NPT by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may 31 - Pendent 8.OK,3/4°NPT the accuracy to which the fixed pipe impair the performance of these de-drops to the sprinkle must be cut. vices. ■T ethnical Corrosion resistant coatings, where The owner is responsible for maintain- Data applicable, are utilized to extend the ing their fire protection system and de- life-of copper alloy sprinklers beyond vices in operating condition. that which would otherwise be ob- The installing contractor or sprinkler Approvals tained when exposed to corrosive at- manufacturer should be contacted UL and C-UL Listed. with any questions. FM, LPCB,and-NYC Approved. (Referto Table Afar complete approval IMPORTANT information including corrosion.resis. Always refer.to Technical Data ■ odell37p rinkler tant status.) Sheet TFP700 for the INSTALLER !I/ Maximum Working WARNING' that provides cautions # Pressure with respect to handling.and instal identification . 175 psi(12,1.bar) lotion of sprinkler systems and corn- Discharge Coefficient ponents. improper handling and in- Numbers K=2.8 GPM/psit12(40,3 LPM/bar7J2) stallation can permanently damage K=4.2 GPM/psi;/2(60,5 LPMibar/2) a sprinkler system or its compo- TY1131- Upright 2.8K,1/2'NPT K=5.6 GPM/psii/2(80,6 LPM/barl/ ) nents and cause the sprinkler to fail TY1231 - Pendent 2.8K,1/2"NPT K=8.0 GPM/psil&(115,2 LPM/bar1/ to operate in a fire situation or cause TY2131 - Upright 4.2K,1/2"NPT Temperature Ratings it to operate prematurely. TY2231- Pendent 4.2K,1/2"NP Refer to Table A and B TY3131- Upright 5.6K,1/2'NPT T Page 1 of 8 JULY,'2004 TFP171 Page 2 of 8 TFP171 ESCUTCHEON 7/16'(11,1 mm) STYLE 10or20 PLATE SEATING NOMINAL RECESSED SURFACE /2 DEFLECTOR 1 MAKE-IN ESCUTCHEON ` ' U i L 6 7/16" 5 2-1/4" (11.1 mm) 11 , 4 (57,2 mm) NOMINAL MAKE-1N2 1-11/16' 2-3116' 3 (39,7 mm) WRENCH. {55,6 mm) FLATS : 7 SSP DEFLECTOR* 2-7/8'(73,0 mm)DIA. 1/2'NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION t-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2=Button Assembly 5-Compression 7-Bushing orifice Seat:on frame. Screw *Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1:. QUICK RESPONSE SERIES TY-FRB UPRIGHT(7Y1131)AND PENDENT(TY1231)_SPRINKLERS 2.8-K-FACTOR, 1,2 INCH NPT ESCUTCHEON 7/16'(11.1 mm) STYLE.10 or 20: PLATE SEATING , . NOMINAL RECESSED SURFACE 1/2 MAKE-IN ESCUTCHEON. SSU NPT DEFLECTOR _ 2-3M6` (11.1_mm) (55:6 mm) NOMINAL. 4 MAKE-IN 1 _ .6. . 2. (38,1 mm) VIIEtENCH (55 8 mm)_ ___ ______FLATS 3 ____ SSP DEFLECTOR* 2-718 (73,0 mm)DIA. 1/2'NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION t-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. $Cfew **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT a Finishes Bulb . . . . . . . . . . . . Glass E Sprinkler:Refer to Table A and B Compression Screw Operation. . . : ...Bronze � Recessed Escutcheon-White Coated, Deflector. . . . . . Copper/Bronze - . - Chrome Plated,or Brass Plated Bushing(K=2.8) . . . . . .Bronze The glass Bulb contains a fluid which e expands wJ enexposed to heat.When N the rated temperature is reached,the Physical Characteristics - fluid expands sufficiently to shatter the M Frame . . . . . . . . . . . . Bronze glass Bulb, allowing the sprinkler to E Button. . . . . . . . . Brass/Copper activate and water to flow. a_ Sealing Assembly . . . . . . . . . . a . . . . . Beryllium Nickel w/Teflont • TFPI 71 Page 3 of 8 ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING *„ NOMINAL RECESSED * SURFACE N' MAKE-IN ESCUTCHEON .SSU . DEFLECTOR 7116 5 (55,6 mm) (1.1'1 rrlA NOMINAL 4 1-1/2' ( MAKE-IN WRENCH (55.6 mm) FLATS 3 SSP DEFLECTOR'' 2-718"(73,0 mm)DIA. --, 1/2'NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION t-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. . . . . Screw '*Pipe thread bonnections per ISO 7/1 can be provided on special request: FIGURE 3 . . . QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1!2 INCH NPT ESCUTCHEON 1/2"(12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL, RECESSED 314" SSU SURFACE MAKE-IN ESCUTCHEON DEFLECTdti (58,Z mm) NOMINAL 4 i MAKE-IN (39.7 mm) WRE TCH (57,2 mm) 3 SSP DEFLECTOR* 2-718"(73,0 mm)DIA. 3/4"NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw "Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,314 INCH NPT Listing is based on the requirements of Design NFPA 13, and FM Approval is based nstallati I on on the requirements of FM's Loss Pre Criteria vention Data Sheets ).Only the Style The SeriesTY-FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow- The Series TY-FRB Pendent and-Up- eon, as applicable, is to be used for ing instructions: right Sprinklers are intended for fire recessed pendent installations. . protection systems designed in ac- NOTES cordance with the standard installation Do not install any bulb type sprinkler if rules recognized by the applicable the bulb is cracked orthere is a loss of Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler Page4of8 TFP171 SPRINKLER FINISH(See Note 7) inch NPT sprinkler joint should be ob- K TYPE TEMP: BULB NATURAL CHROME WHi1E tainted with a torque of;10 tv 20 fLlbs. UOUID BRASS PLATED POLYESTER 27,8 )o A me is to b used ed ft lbs.(40,7 Nm)of.torque is to be u to install sprinklers with 3/4 NPT con- 135°F157°C Orange nections. I ighertevels.oftorquemay PENDENT. 1s.°F/68°C Red distort the sprinkler inlet End cause (M.231) 1,2,3.5 leakage orimpairmentof the sprinkler. and. 175°FI?9°C Yellow UPRIGHT 200" "C Green Do not attempt to make-up for insuffi- 1t31 F/93 cient adjustment in the escutcheon 28 • ) 286°F/1.41°C Blue plate by under-or over-tightening the 112^ sprinkler. Readjust the position of the NPT 135°F/57°C Orange sprinkler fitting to suit. RECESSED 155°F/66°C Red PENDENT' The Series TY-FFtB Pendent and Up- (TY1231) t75°F/79'C Yellow right Sprinklers must be installed in accordFigure 5 '200°F/93"C Green 1.2.5 tionsroance with the ttowing tnstruc 135`F/57^C Orange Step 1. Pendent.sprinklers are to be RECESSED 155'F188'C Red installed in the pendent position,and PENDENT _ upright sprinklers are to.be installed in . (TY1231)"" i75'F179°C Yellow the upright position; Figure,6 2WFI93°C Green Step 2. With pipe thread:sealant ap- 135°F/57°G Orange plied to the pipe threads,hand tighten PENDENT .` p the sprinkler into the sprinkler fitting. 155 FJ68°C. Red • (T Y2231) Step 3.Tighten the sprinkler into the .and 175°F/79°C Yellow sprinkler.fitting using only the W-Type UPRIGHT.:..-200"FJ90°C Green 6 Sprinkler Wrench(Rat Figure 13) a.2 (TY2131). With reference to Figures 1.2,3;and 286°F/141'C . Blue . 2 ;4;the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler.wrench NPT. t.35-F/ -C. :,Orange flats. RECESSED _i55°F/68°C Red — PENDENT:.: g1p 175"F/79^C Yellow The Series TY-FRB Recessed Pen- Figure 7 2oo'F%93"G Green dent Sprinklers:rnust-be installed in accordance with the following instruc- 135°F/57°C. ..Orange tions. RECESSED 155'F/&8°C. Red Step A.After installing the Style 10. PENDENT • 20, 30,or40 Mot rig Plate,as apply- (n2231)- i7�t_79°C Yellow .cable, over the sprinkler threads and Figure 8 2o0"i/93°C Careen with pipe thread seaiarit applied to the pipe threads, hand tighten the sprin- NOTES• - kler into the sprinkler fitting. 1.Listed by Underwriters Laboratories..Inc.(UL)as Quick Response Sprinklers. Step B.Tighten the sprinkler into the 2.Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL)as Quids Response sprinkler fitting using only the W-Type Sprinklers. 7 Recessed Sprinkler Wrench (Ref. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprin- Figure 14).With reference to Figure 1, were• the W-Type Approved by the City of Now York.under MEA354-01-E. 2, 3, and 4, 7 Recessed 7.Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprin- Sprinkler Wrench is to be applied to klers are UL and C-UL Listed as Corrosion Resistant Sprinklers, the sprinkler wrench flats. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4'Total Adjustment Step C.After the ceiling has been in Recessed Escutcheon,as applicable, stalled or the finish coat has been ap- Installed with Style 20(1/2'NPT)or Style 30(3/4"NPT)1/2"Total Adjustment plied,slid e on th e Style 10,20, 30,or Recessed Escutcheon,as applicable. 40 Closure over the Series TY FRB Frame and Deflector only.Listings and approvals apply to color(Special Order). Sprinkler and push the Closure over N/A:Not Available the Mounting Plate until its flange TABLE A comes in contact with the ceiling. LABORATORY LISTINGS AND APPROVALS 28 AND 42K-FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPTsprinklerjoint should be present.The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ftlbs. (9;5 to 19,0 Nm).A maxi- (1,6 mm) for the 135"F157°C to 3/32 mum of 21 ft. lbs. (28,5 Nm)of torque inch (2,4 mm) for the 286°F/141°C may be used to install sprinklers with temperature ratings. 1/2 NPT connections. A leak tight 3/4 • TFP171 Page 5 of 8 SPRINKLER FINISH(See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE " LEAD LIQUID BRASS PLATED POLYESTER COATED 135"F157°C Orange PENDENT 155'F/68°C Red (TY3231) 1,2,3,4,5,6,7 1,2,3,5 and 175'F/79'C Yellow UPRIGHT 200'F/93"C Green 5.6 (TY3131) 286FI141-C. Blue 112" NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1.2.4.5 N A (TY3231)' 175°F/79°C: Yellow Figure 9 200°F/93°C Green 135"F/57'"C Orange RECESSED 155°FJea;C Bed PENDENT 1,2,3,4,5 1,2.4,5 N/A (Y3231p": :175°F/79°C Yellow . . . . . . Figure 10 200"F/93°C Green 135°F/57"C Orange PENDENT 155°F/68°C Red (TY4231) 1.2 5 and 1T5'F/79°C - Yellow t,2,34,5,6,7 3,4,5,6,7 UPRIGHT .200°F/93"C Greed :(T 8.0 Y4131) 286°F/141°C Bide 3/4" NPT 135'FI5rC. :Green RECESSED 155"F/68"C Orange PENDENT 2,4 5 (TYa231p.. 175"F179°C ` ..Red N/A figure 11 200'F/93°C Yellow 135°F/57°C Orange - RECESSED 155°F/68°C Red PENDENT 1,2;3 4,5 (TY4231)- 175"F/79"C Yellow N/A Figure 12 200"F/93/L _.C Green NOTES: 1.Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers. 2.Listed by Underwriters-Laboratories,Inc.for use in Canada(C-UL)as Quick Response Sprinklers. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers, 4.Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers;however,the LPCB does not rate the thermal sensitivity of recessed sprinklers. - 5.Approved by the City of New York under MEA 354-01-E. 6.VdS Approved(For details contact Tyco Fire&Building Products,Enschede,Netherlands.Tel.31-53-428-4444/Fax 31-53-428-3377). 7.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094x/06)as Quick Response Sprinklers. 8.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. Installed with Style 20(1/2"NPT)or Style 30(3(4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0K-FACTOR SPRINKLERS Page 6 of 8 TFP171 2-7/8'DIA. 2-7/8'DIA. 5/811/4• (73,0 mm) 3/4'(19,1 mm 11231/8' (73.0 mm) 1/2'(12,7mm) (15,916,4 mm) 2-1/4'DIA. 1/4'(6,4 mm) - (12,7±32 mm) 2-1/4'DIA 1/4'(6.4 mm) FACE OF (57,2—1 MOUNTING FACE OF (bT,2 mmj MOUNTING SPRINKLER PLATE SPRINKLER PLATE FTTTING FTTnNG MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5116'(33,3 mm SER IES SEES 1-5/16' 33,3 mm) TY-FRB 13/16'(20,6 mm) TV-IRS 1-1/16'(27,0 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 12 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 12 INCH NPT 2.8 K-FACTOR,1/2 INCH NPT 2-718'DIA. 2-7/B DIA. 5/8±1/4' (73.0 mm) 3/4' 19.1 mm) 1n ' (73,a 1/2'(12,7mm) (15,916,4 mm) 2-1/4'DIA. 1/4'(6,4 mm) L(12,7:32 mm) 24/4'DIA. 1/4'(6,4 mm) FACE OF (7.2 mm) MOUNTING FACE OF (572 mmj MOUNTING SPRINKLER PLATE SPRINKLER PLATE rw _L F \ I ' FITTING FITTING 'MOUNTING MOUNTIN SURFACE •,• ... j SURFACEG / • 7Y CLOSURE SERIES 1-1/4 31,8 mm CLOSURE SERIES 1-1/4'(31,8 mm) TY-FRB 3/4'(19,1 mm) TY-FRB 1'(25,4 mm) FIGURE 7 FIGURE 8 SERIES.TY-FRB RECESSED PENDENT - SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 12 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR,1/2 INCH NPT 4.2 K-FACTOR,12 INCH NPT used to cover a clearance hole, may and after-installation.Sprinklers dam- Care and delay the time to sprinkler operation in aced by dropping, striking, wrench a fire situation, twist/slippage,or the like,must be re- III atnfenance Sprinklers that are found to be leaking placed.Also, cr�k replace e any sprinkler that The Series TY-FRB Sprinklers must be or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation maintained and serviced in accord- must be replaced. Section). ance with the following instructions: Automatic sprinklers must never be Frequent visual inspections are rec- painted, plated, coated or otherwise eq p NOTES altered after leaving the factory.Mod ommendedto be initially performed for Before closing a fire protection system fled sprinklers must be replaced. corrosion resistant coated sprinklers, main control valve for maintenance Sprinklers that have been exposed to after the installation has been corn work on the fire protection system that corrosive products of combustion,but plated,to verify the integrity of the cor- it controls,permission to shut down the have not operated,should be replaced rosion resistant coating. Thereafter, affected fire protection system must be if they cannot be completely cleaned annual inspections per NFPA 25 obtained from the proper authorities by wiping the sprinkler with a cloth or should suffice;however,instead of in- and all personnel who maybe affected by brushing it with a soft bristle brush. specting from the floor level,a random by this action must be notified. sampling of close-up visual inspec- Care must be exercised to avoid dam- tions should be made,so as to better Absence of an escutcheon, which is age to the sprinklers -before,during, determine the exact sprinkler condi- • TFP171 Page 7 of 8 2-7/8'DIA. 2-7/8'DIA. (73,0 mm) 5/811/4' 3/4 (19,1 mm) 1l2t1/8• (73,0 mm) 112' 12 7 mm ) (15,916,4 mm) 2-1/4'DIA. • 114'(6,4 mm) J (127 mm) 2-1/d'DIA. 114' FACE OF (�" ) MOUNTING FACE OF ( nm) I I MOUNTING SPRINKLER PLATE LSPRINKLER PLATE FITI7WG �� 1/B' I 118' MOUNTING I �� SURFNACE SURFACE / CLOSURE SERIES 1-1/4'(31,8 mm} CLOSURE SERIES 1-1/4' 31,8 mm) TV-FRB i .,,0 1 .., FIGURE 9 FIGURE 10 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT i : 56 K-FACTOR,1/2 INCH NPT 2-7/8'DIA 2-7/8'DIA. 5/8±1/4' (73,0 mm) 3/4' 19,1 mm (73,0 mm) 1/2. 12,7 mm (15,9±6,4 mm) 1/4' 6,4 mm) 1/211/8' 2-1l4'DIA ( r(12733?mm) 2-1/4')J 1/4'(84 mm) (57,2 mm) (57,2 mm) L !.' .iL SPRINKLER I ��PLA�c 1 ACG Cr I ML.PTFIIR�_ _ _ _ PRINKLER p(y4TE FITTING Ire• ' I . MOL1NTiNG MOUNTING $LJRFArF SURFACE. _ CLOSURE SERIES_ 15/16 (33 3 mm) CLOSURE SERIES t-5/16. 33,3 mm TY-FRB 13/16'(20.6 mm) TY-FRB - 1-1/16•(27.0 mm)' FIGURE 1:f FIGURE 12 SERIES TY-FRB RECESSED PENDENT - SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TYPO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON B.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT lion and the long term integrity of the corrosion resistant coating, as it.may WRENCH be affected by the corrosive conditions RECESS present. WRENCH RECESS The owner is responsible for the in- (END A`USED FOR spection,testing,and maintenance of 1/2'NF MODELS) their fire protection system and de- - vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- WRENCH RECESS tion Association (e.g., NFPA 25), in (END'13'USED FOR PUSH ENSUR H addition to the standards of.any other 3/4•NPT MODELS) 1N TO ENSURE ENGAGEMENT authorities having jurisdiction he in- SPRINKLER stalling contractor or sprinkler.martu- FIGURE 13 WRENCHING AREA facturer should be contacted relative to W-TYPE 6 SPRINKLER any questions. WRENCH It is recommended-that automatic • FIGURE 14 - sprinkler systems be inspected, local requirements and/or national W-TYPE? RECESSED tested, and maintained by a qualified codes. SPRINKLER WRENCH Inspection Service in accordance with Page 8 of 8 TFP171 P/N 57 - XXX X.- XXX PERATURE MODEL/SIN I RATING SPRINKLER 330 2.8K UPRIGHT(1/2'NPT) TY1131 135 135'F/57°C 331 2.8K PENDENT(1/2'NPT) TY1231 1 NATURAL BRASS 155 155°F/68°C 340 4.2K UPRIGHT(1/2'NPT) TY2131 4 WHITE POLYESTER 175 175°F179°C 341 4.2K PENDENT(1/2'NPT) TY2231 3 WHITE(RAL9010) 200 200°F/93°C 370 5.6K UPRIGHT(l/2'NPT) TY3131 9 CHROME PLATED 286 286°F/141°C 371 5.6K PENDENT(1/2"NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT(3/4'NPT) TY4131 391 8.0K PENDENT(3/4'NPT) TY4231 *Eastern Hemisphere sales only. . . . .TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS LORY, FOR .INCIDENTAL, INDIRECT, Recessed Escutcheon: ►mited SPECIAL-OR.CONSEQUENTIAL Specify:Style.(specify)Recessed Es- DAMAGES; INCLUDING BUT NOT cutcheon with (specify finish), P/N Warranty UM(FED TO LABOR CHARGES RE- (specify). GAFIDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED *12' (15mne) Products are warranted solely to the ABOI T.THT E POSS.IBlUTY-OF S Jl,L Style 10 original Buyer for ten (10) years DAMAGES, AND IN NO. EVENT Chrome Plated _... .... P/N56-701-9-010 against defects in material and work- SHALL-TYCO FIRE PRODUCTS' U- While Coated • .... .... P/N 56.701-4-010 manship when id for and.properly ABILITY EXCEED AN -AMOUNT Pa _ installed and maintained under normal EQUAL TO THE SALES PRICE., use and service.This warranty will ex- 1/2' (15 mm) pire ten (10) years.from date of ship- THE FOREGOING WARRANTY IS Style 20 MADE IN LIEU OF ANY AND ALL ment by Tyco Fire Products.No war- Chrome Pleteo.............P/N 56-1o5-s-o10 rant" is givetr for. .products .or while Coated..............P/N 56-705-4.010 corn entS manufactured corn WARRANTIESwhite„RAt9010' .... ... P/N 56-705.3-010 Hies not affiliated by owrier�shtp with OF:'MERCHANTABILITY AND FlT- Brass Plated............... P/N 56-705-2.010 Tyco Fire Products orforproducts and NES$ FDR A PARTICULAR''PUR- 3/4 (20mm) components which have been subject POSE. Style 30 to misuse:improper installation,corro- Chrome Plated............ P/N 56-705-9-011 Sion,or which have not been installed, White Coated............. P/N 56-705-4-011 maintained.modlfi6d Or repaired IR aC- ' White RAL9ottr.....-..... P/N 56=7053011 cordance with applicable Standards of Ordering Brass Plated.............. PM 56 7orr2-011 the National Fire Protection Associa- Procedure 3/4' (20mm) tion,and/or the standards of any other Style 40 Authorities Having Jurisdiction.Mate- telditttiushbcal distributor for avail- Chrome Plated............ P/N 56-700-9-010 rials found by Tyco Fire Products to be abifiWindicate the White Coaled............. P/N 56-700-4-010 defective shall be either repaired or "'" White RAL9010'........... P/N 56-700-3-010 replaced, at Tyco Fire Products'sole name.Refer to Brass Plated.............. P/N 56-700.2-010 option.Tyco ca Fire Products comnplete fisting neither as- plee u 'Eastern Hemisphere sales only. sumes, nor authorizes arty person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify:W--Type 6 Sprinkler Wrench, parts of products.Tyco Fire Products Thread Connections: P/N 56-000-6-387. shall not be responsible for sprinkler Specify: (Specify Model/SIN), Quick system design errors or inaccurate or Response,(specify K-factor),(specify Sp c fy:W-W-T S ype p Huller Wrench, 7 7 S incomplete information supplied by temperature rating), Series TY--FRB Buyer or Buyer's representatives. (specify Pendent or Upright)Sprinkler it3 NO EVENT .SHALL TYCO FIRE with(specify type of finish or coating), - PRODUCTS BE LIABLE, IN CON- PIN(specifyfrom Table C). TRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 - ® • s-6 NCia1Lic`Ism ISO 8)31 ctRr;RE0C(V,V6 . Series 717 A reL.ock® Check Valves PRODUCT DESCRIPTION Series 717 FireLock check valve is a CAD-developed design that is hydrodynamically efficient.A totally rubber encapsulated disc on 4-12'(100-300 mm)sizes provides superior corrosion resistance.This single disc design incorporates a spring assisted feature for non-slamming operation.For systems requiring a Riser Check option refer to section 10.09. The 4'(100 mm)and larger sizes are provided with upstream and downstream drains and a welded-it nickel seat design.All sizes of Series 717 can be installed in the vertical or horizontal position to provide leak-free sealing under conditions as low as five feet of head.Each valve is factory tested to 500 psi seev,Uauric (3440 kPa).The 2117 and 3 (65 and 80 mm)sizes are UUULC Listed and 4'(100 mm)sizes and larger are pLAMallon ions UUULC Listed and FM Approved for services up to 250 psi(1725 kPa).Sizes 4-8'1100-200 mm(except Sizes 2½-3 foroetaes. 165.1 mm size)are VdS approved. Grooved ends allow fast,easy installation with just Victaulic couplings or the valve may be mounted to Flanged(ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flange f or Style 744 FireLock flange adapters on either end. ©����ULC \% seaVictaulic publication 10.01 for details. Sizes 4-12' DIMENSIONS .s—A & ValveSfep _____ _____ t>mlalsions 1rleheshniuimeters Actual p Nmei ia to C WWgttrs�. Diameter Diameter EtoE tlrJmm tnJmm A B C D E J' 8 P It kg Typical -3' 211 2.875 3.88 4:26 357 - - - - - - 3.6 YP65 73.0 99 108 91 - - - - - - 1.6 76,1 mm 3.000 3.88 426 357 - - - - - - 3.6 75.1 99 108 91 - - - - - - 1k 3 3.500 4.25 5.06 4.17 - - 4.5 -►I R h" 80 88.9 108 129 106 - - - - - 2.5 c-• 4 1 4.500 9.63 6.00 3.88 2.75 3.50 2.00 430 3.50 3.3S 20.0 P C 100 114.3 245 152 99 70 89 51 T'.4 69 35 9.? f •_.__ 4 51 5.563 10.50 6.20 4.50 4.17 2.15 598 4.08 3.98 27L D E 125 141.33 267 173 114 - 106 55 149 1C4 101 123 I� Ii 5.500 10.50 6.80 450 - 4.17 2.15 5.88 4.08 3.08 27D {h—Kf l 135,7 mm t 139.7 267 173 114 - 106 55 149 10,4 101 12.3 .- B 0 yw.1�T fin Drain 61 6.625 11.50 8.00 5.00 - 4.50 2.38 6.67 4.733 3.89 38.0 � NPT DaNsaag,n Dmtr 150 168.3 292 20"3 127 - 114 61 1L4 120 W 17 r NPT rte'�°°°0 165.1 mm 6.500 11.50 8.00 5.00 - 450 2.3a 6.57 4.73 3.89 380 165.1 292 203 127 - 114 61 169 120 99 171 Typical 4-B. 81 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.9 10 10.750 17.00 12.00 7.09 5.96 6.69 215 10.92 6-73 - - 1008 i 250 2738 432 305 183 151 ,70 55 277 171 45.4 P c 12 17.750 19.50 MOD 3.06 6.91 7-64 231 17.81 7.73 _ 140.0 ��_ {. 300 323.9 495 356 2C5 176 194 N 925 19b D E I VdS Approved 6µS 1 � 1 lit— 'll'rY NPT U9eraem Drain %'NPT Doansveem Drain Typical 10-12' 2 NEB3IS1EREDTRN)DA ICo-VrCTALUC-CCCPrR ff2m4VICTAriiC-PRINTED INU-SA-SKUCYCAS-aevpxc uAIE\r Vtctaulic compsrry of Amsica- Phone 1-800-PICK-Vac(1- X)-142-5812)- Fax 610-250-8917' e-mail:pc@tictsjtic.com Vklawrir(Uvn perry of Cegwle- PYne 905.864-74U- vex 5.884.9774- e-mtil: irrarwr4e eiatJtclnca Vfaaure Europe- Phone i2-9 381-1500- Fax 32-9-380.4438- a o*it vicar &be Viaeulic Ameb Letma- Pitons 610-558-33(1)- Fax 610-559-3608- e-mail sical@vIUata.com rs 'rte E ry6 ViclaurlcAsia Paci k- Phone 86-21-58805151- Fax 86-21-58851298- e-ma*virapwviaau5c.com �.s 4Cr[i�.i i.r FLOW CHARACTERISTICS NOTE:Placement of c heckvalvestoo (ES 717 close to sources of unstable flow will fi.0 shorten the rife of the valve and potentially may damacje the system. 5Y R W OFWA1E( To extend valve rlfe valves should be (t16rF(t6°C) installed a reasonable distance 1)QialGKYALVE downstream from pumps,elbows expanders.reducers or other similar ,.. devices-Sound ping practices dictate a minimum or leas(5)times the pipe diameter for general use. O Distances between three(3)and rive _ ry 3 •4 o 1'% (5)diameters are allowable provided gj the flow velocity is less than eglht i8) fl feet per second(2.4 mps).Distances less than three(3)diameters are not ) t.0 recommended and will violate the 0.9 Victautic product warranty. 0 (t$ O EEtE ' EE _1 ' W Ob tr t2n � a I I ! ii 82 __ T i I _ i . _ ± . - 9t It 20 30 40 f E 60100 200 ?3.4 401) 609 1,000 2,089 4,000 6,600 10,00 20,60(1 W ;W .$elect fLflt�f RATE—G.P.M. MATERIAL SPECIFICATIONS Body.Ductile iron conforming to ASTM A-536.grade 65-45-12.Ductile iron conforming to ASTM A-395, grade 65-45-15.is available upon special request.2h1z-3 (65-BO mm)sizes PPS coated.4-1Z(100- 300 mm)sizes painted black enamel. Body Seat:2'/z-3'(65-80 mm)sizes PPS coated.4-12'(100-300 mm)integrally welded on nickel alloy. Disc Seal or Coating: • Grade E"EPDM EPDM(Green color code).Temperature range-30•F to+230'F(-34'C to+110'C).Recommended for cold and hot water service within the specified temperature range plus a variety of dltte acids.oil-free air and many chemical services.UL classified in accordance with ANSI/NSF 61 for cold+86'F(+30'C) and hot+180'F(+82`C)potable water service.NOT RECOMMENDED FOR PETROLEUM SERVICES. 'Services listed are General Service Recommendations only.It should be noted thatthere are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs:2h/z-3"(65-80 mm)Aluminum bronze conforming to ASTM B-1 48 with Grade'E"Seal. 4-12'(100-300 mm)ductile iron conforming to ASTM A-536.grade 65-45-12,fully encapsulated in Grade"E'elastomer. Shaft:2'! -3'(65-80 mm)Type 416 stainless steel.4-12'(100-300 mm)Type 316 stainless steel. Spring:All sizes lype 3021304 stainless steel. Shaft Plug:2'!z-3'(65-80 mm)only;SAE Hex Socket Type conforming to ASTM A-576.cadmium plated to military specifications QQ-P-416A,class 3 type 2.4-12'(100-300 mm)only:carbon steel zinc plated to ASTM B-633. Pipe Plug:4-12'(100-300 mm)only:carbon steel zinc plated to ASTM B-633. This product shall be marxlactured by Victauliic Company.All products shall be iretailed in accordance w`h aerent Victaufe insalIariruassembly inswctiors. vcyaurc reserves the right to change product specricators.designs and standard equipment without notice and without inwning obligations. 2 Series 717 FireLock-Check Valves • Schedu L4O®/Séhé u Ie40® Fully Listed and FM Approved .Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product.Although these products do not require separate approvals,Schedule-1O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-l0(i'/4'—8")pipe and Sch-40(1"—2 ")pipe have passed the same thorough lab testing as our other listed pipe products,and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.. NPS Nominal 1.0. WI Wt N Fi 20 Ile Pc R 2t 4 WW WN.Ift 2 I rt25' � ww ( � l7 ! Schedule-10/Schedule-40 product can be Irr,mm In;mm Ibsift;Kg/m L Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg "hot-dip galvanized to meet FM 1• 1.049 1.680 205 70 2,470 2,822 2,940 requirements for dry systems in accordance with the zinc coating 25 26.6 25 3.05 70 1,120 1,280 1,334 specifications ofASTMA-123. 1'/; 1.380 2270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4-36 51 1,103 1,260 1,313 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean,durable surface.It is also 50 525 5.4 7.63 30 1,043 1,192 1,242 paint-ready for custom color applications 2'h' 2.469 5.790 7.86 19 750 without special preparation_ 2,048310 2,197640 1,247 65 627 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied 'Ibbe&Conduit Fire Sprinkler pipe F1Ik- + products up to 4.5000"in diameter is coated with our new Antibacterial For- NPS Nominal I.D. WL WI.(1120 FlDed) Pc Wi1ll$(2i') WNlrt(24') W"(25' mina,ABF".In scientific laboratory in;mm In mm Lbs Kym Lbs/Fi Kg/m Lift Lbs;Kg Lbsr Kg Lbs;Kg test,ABS proved to have superior resis- 1' 1.097 1.400 1.81 91 - 2,675 3,053 3,185 tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 walls,thereby delaying or possibly pre- 1'/; 1.442 1.810 2.52 81 760 venting the onset of Miesobiol 2,0 2 1, 8 1,252 y 32 36.6 2T 3.75 61 1,052 1,208 1,252 Influenced corrosion(MC)when the 1'k' 1.682 2.080 3.04 61 2,684 3,045 3,172 First Sprinkler System is first installed 40 427 3.1 4-52 61 1,208 1,381 1,439 . - 2 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 628 37 930 1,063 1,108 Meets"Buy American"requirement 2W 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 669 5.3 8.77 30 1,809 1,153 1,201 the USA,Canada and Mexico. 3' 3.260 4.330 7.94 19 1,728 1,975 2,057 80 828 6.4 11.82 19 784 896 933 4' 4.260 5.610 11.78 19 2,238 2,558. 2,665 Schedule-10/Schedule-40 pipe are in 90 1082 8.3 1753 19 1,015 1,160 1,209 compliance with the following: 5' 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A-135,and NFPA 13.Both pipe 6' 6.357 9.290 23.03 10 1,951 22230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: -Welded Outlets FN1 c: -Hydrostatic Pressure Listed Approved Listed •Side Wall Rupture •Vibration Test *jlCO/flow Control dhed 16100 S.Lathrop'Harvey,IL 60426 Customer Service: 11350 Norcorn Rd.-Philadelphia,PA 19154 (800)882-5543 TUBE&coNourr 2525 N.27 th Ave.•Phoenix,AZ 85009 Fax 708-339-1806 S5-3 I- • ?1:I:is.Ll1:1416:11J�a cem s)1:iN' 63 teT7Tla3�. ® i�' a SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 005 - - -- - WITH VIC-PLUST'"GASKET SYSTEM (NORTH AMERICA ONLY) FireLocke'Style 005 rigid coupling has a unique, patentee angle-pad design which allows the housings to offset while clamping the grooves.By permitting the housings to slice on the anglec bolt pads,rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems.Angle-pad design permits assembly by removing one nutlbolt and swinging the housing over the gasket.This PAtENtrn reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire ViCPIuT protection systems. ceri•c Jy-.-- Vic-PtusTM Gasket System- In North America,Viclaulic°offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested.The Vic-Plus''System(patentee)is dry,clean,and non-toxic_It reduces assembly time substantially and eliminates Inc mess and chance of over- lubrication.Please refer to the latest copy of the Victaulic Field Installation Handbook(1-100)for supplemental lubrication requirements and dry pipe fire protection system notes. E+ggaaIedf cry LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication.Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. : 1l —3E 175 175 '- 175 :::$:;:114—?i 300 WA : WA ::tyt3:;=114-2 300 WA WA Rt lis-2; 300 Nm N/A :_cTE:• 144—d= N/A N//L 300 —2 11,5 WA WA 300 5-8 1300 300 300 :EZ:: 4-5€ 3tkK WA 300 :m ......... _ _ELT:x.11.—2 i 300 300 WA - PF:=::716-4 N/A fdiA 300 ::fF:c: a i lYa—d' 303, 300 30C GAL=T;11:—? tilt WA WA :1,1,75:1?-2` 300 300 WA 311 144_2T30D 300 PYA .M1T:: 145=2; 300 NsA : N/A ":Y$ :Its—a; 3iA' i00 300 f:i'1Y-4" I75sp FliA 1T. :::A ::i;11n—d` 300 k:A-f 300' 'FM approved for service En 1 yc—4'pipe. i UL listed for service up To pipe onlq. UL listed for service up to 3 only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By _ Spec Sect Para Location Date Approved Date www,victautic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02006 VICTAULIC COMPANY.ALL F ERME FIGHTS FESD.PRINTED IN THE US& 1,C tint! . FtEV-i t0021 IPS CARBON STEEL PIPE-FIRE PRf� JN PRODUCTS I' 10.0- FireLock 011 Rigid Coupling STYLE 005 WITH VIC-PLUS1h GASKET SYSTEM(NORTH AMERICA ONLY) DIMENSIONS kIIR. I hAul :]Ze:::E:F 1.660 350 755 0.05 •-..,i` 275 4.50 1.88 12 42.4 2413 3370 12 70 114 148 OS x:::1:5:::: 1.900 350 990 0.05 T 3.00 435 1.88 12 EIc :iFi•` 483 2.113 -14 1.. o3x`Ys` 76 121 148 ; 05 Rated far wet and dry sprinkler s STems at 3:::::::'::::: '; 2375 350 1550 0.07 350 + 525 186 lb 350psi.2413kPafor115-4/32-100mm :F:SO:::i:iEl 603 2413 6901 1_r I 89 ` 133 148 0.7 sues znd 300 psi/2068kPa(or 414-8%108 F:::;: :::::1 2515 350 2220 OAT 4.00 535 -1B8 19 -200 mmgrooved or ' :::::' T30 2413 10110 17 hr- 146 138 .09 5......_ _ Schedule 40 cut or roll grooved steel pipe. . ........i 3.000 350 2475 Ole 413 535 1.88 12 Style 005 is rigid and does not accommodate :%`�l+? :: 2413 --- `Y al ._.-:..::: 76.1 11010 1J IC5 146 148 0.9 expansion,contraction or angular deflection. -- _; [;:: 3.5W 53 3365 0.07 4.63 0.13 0.88 21 80:::a-:€ 88.9 2413 14985 13 ` ' 118 156 048 lxt ::::::: 4500 350 5565 0.16 , ...,, 535 7?5 213 3.1 ::itTO:::::: 1143 2413 24770 4.1 4.1 ' 146 184 54 1.4 10833an f::I 4250 300 455 0.16 , s-4i?.. 5.63 7?5 2.13 3.1 108.0 2058 18940 4.1 ld3 184 54 1.d - 0.16 6.88 9.00 =:::5.:::?:C 5.563 300 P9L1 2.13 45 : 1413 -'068 32445 4-1 2-to x 3 175 229 54 2.0 :::...:............c----............-. ..._....---......_.......... ........... ..... ...... .. .__. ........ 5.250 300 649` 0.16 ' :...053 9.30 2.13 4.5 33tTrjs;:s , --}`-x253; 229 133.0 € ,06b 28�t0 _ at � 76854 20 55000 300 7125 0.16 i 2-13x23:1 6.88 9.0t) 213 = 4.8 #' :: 1397 i 2068 31715 4.1 i l in 229 54 22 6.625 300 10340 016 I Y 8110 10.00 ..13 : 5.0 I. 0EiiH- 168.3 2068 46020 4.1 t 2 L 3 PT 254 53 '_3 6?St7 300 9200 0.16 ,_iR 12 .` 7663 10.00 2.13 53 - ;1 159.0 2068 40955 4-1 194 254 54 25 6500 300 9955 016 5 3 8.15 10.00 2.13 5.5 x -- 165.1 206.6 44295 4.1 205 254 54 23 _......_...._...t............. ...................................._....... :: 825 300 175'-5 ,01a. t 1050 13.14 2.63 11.3 '-r-2 2191 {-:20611 + 58000 SE tt t i 2E 334 67 51 Working Pressure.and End load are total.from all internal and a vernal toads,based on standard weight.000511 steel pipe,standard roll or cut grooved In aaordance with VICT21 is spedfica1kns Contact Victadicfor perfor- mance on orherpipe. WARNNG:FOR ONE 17ME FRO TE.5TONLY,the Maximum Joint Workirsq Pressure may be increased to 1 112 limes the floures shown. t The allowable pipe separation dimension shown is for system layout purposes only.Style 005 couplings are con- sidered rigid connections and will rot accommodate e ppansilrr:or contraction of:he piping system. @ Number of bolts required equals number of hausina segments.Metric thread si a bolts ere available(color coded gold)for all couplira sizes upon request Contact 18ctautic for details. S Style 005 couplings are Vd5 and LPC Approved to 128ad175psL www.victaulic.com a Z__ ctauIicr VICTAUUC IS A REGISTEFED TRADEMARK OF VICTALILIC CCYAPAFEI'.0 2606 VICTAULIC COMFANY.ALL RIGHTS RESERVED.PRINTED IN THE LISA. VV �ILt' IFS CARBON STEEL PIPE-FIRE PRoTECrPRQE3UCTS - I U.UZ • �'�'� �'_-L�lF :.,�:S E_.t`, F c Ftyy Y:az i 4�T•e1-- _- STYLE 0O5 WITH VIC-PLUS'TM GASKET SYSTEM(NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12:Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating:Orange enamel(North America);red enamel(Europe) • Optional:Hot dipped galvanized Gasket: • Grade"E"EPDM—Type A Vic-Plus'Gasket System A • (Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E°Type A Vic-Plus"Gasket System,requiring no field lubrication for most installation conditions. • Grade"L"Silicone Recommended for dry heat,air without hydrocarbons to+350°F and certain chemical services. For dry services,Victaulic continues to recommend the use of Grade E Type A FlushSeate Gasket. Contact Victaulic for details. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to-40°F/-40°C.Based on `typical'pipe surface conditions,supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water.Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams.Victaulic continues to recommend the use of FlushSeal gaskets for dry services_ www.yictaulic.com ..y VICLAULIC IS A REGISTERED TRADEMARK OF VICTAuliC COMPANT-O 2ra)6vICTAULIC COMPANY.ALL RIGHT$RESERVED.r'srNnEO IN iNE LISA. _____ (' F EV_t r[�� FF E�F {{ £ '.L. oc t'�� Rigid STYLE 005 WITH VIC-PLUS'T GASKET SYSTEM(NORTH AMERICA ONLY) GENERAL NOTES WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Viclaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Viclaulic or to Victaulic specifications.All prooucts to be installed in accordance with current Victaulic inslallation/assembly instructions.Viclaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing Handbooks are included with each shipment of Viclautic products for complete installation and assembly data,and are available in PDF format on our website at www.victauhc.com. II 11111IINIIIII 1IIl WCAS-697KR4 For complete contact information,visit www.victaulic.ccm 10.02 1538 REV I UPDATED 9/2006 Aic--tauhc� VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2006 VICTAUUG COMPANY ALL RIGHTS RESERVED.PRIMED IN THE USA. I0.O2 COMMERCIAL FIRE & COMMUNICATIONS, INC. HYDRAULIC DESIGN INFORMATION SHEET Name: GOIN' POSTAL Date: September 24,2008 Location: 4941 4th ST. System No.: 10261 ZEPHYRHILLS, FL. 33542 Contract No.: 10261 Building: Drawing No.: FP-1.0 Contractor: COMMERCIAL FIRE&COMMUNICATIONS Calculated by: JEB File Name: GOIN POSTAL.the Construction: © Combustible ❑ Noncombustible Ceiling Height: 11'-4" ft • Occupancy: MERCANTILE AHJ: CITY OF ZEPHYRHILLS SYSTEM DESIGN ❑u NFPA 13: ❑ Light Hazard ❑x Ordinary Hazard Group: 2 ❑ Extra Hazard Group: Figure: 11.2.3.1.1 Curve: ❑ Other(Specify): ❑ Specific Rulling: Made By: Date: Area of Sprinkler Operation: 1106 sqft System Type: 0 Wet ❑ Dry ❑ Deluge ❑ Pre-Action Density: .2 gpm/sqft Area per Sprinkler: 100 sqft SPRINKLER or NOZZLE Hose Allowance Inside: gpm Make: TYCO Model: TY3331 Hose Allowance Outside: 250 gpm Size: 1/2" in K-factor: 5.6 Rack Sprinkler Allowance: gpm Temperature Rating: 155 °F CALCULATION SUMMARY Flow Required: 452.74 gpm Pressure Required: 30.55 psi At: "C" Factor Used: Overhead: 120 Underground: N/A WATER SUPPLY WATER FLOW TEST PUMP DATA TANK OR RESERVOIR Date: SEE Rated Capacity: gpm Capacity: gals Time: BELOW At: psi Elevation: ft Static: psi Elevation: ft Residual: psi WELL Flowing: gpm Proof Flow: gpm Elevation: ft Location: CALCULATION FOR DEMAND ONLY Source of Information: COMMODITY STORAGE Commodity: Class: Location: Storage Height: Area: Aisle Width: Storage Method: Solid Pile: % Palletized: % Rack: % RACK STORAGE ❑ Single Row ❑ Conventional Pallet ❑ Automatic Storage 0 Encapsulated ❑ Double Row ❑ Slave Pallet ❑ Solid Shelving ❑ Nonencapsulated ❑ Multiple Row ❑ Open FLUE SPACING CLEARANCE FROM TOP OF STORAGE TO CEILING Longitudinal: in Transverse: in ft in Horizontal Barriers Provided: File: GOIN POSTAL.the Page 1 of I Hydraulic Summary WATER SUPPLY INFORMATION: Static (psi): 0.00 Residual (psi): 0.00 @ (gpm): 0.00 Hose (gpm): 250.00 System req. (gpm): 452.74 (psi): 30.55 Supply available: 0.00 psi Safety margin: -30.55 psi WATER SUPPLY IS INADEQUATE! Maximum velocity in the system is: 12.75 ft/sec in the pipe between Nodes: 14 and 15 Continuity at all nodes satisfied to: 0.01 gpm Pipe Type Legend Fitting Type Legend 10 = Schedule 10 GV = Gate valve 40 = Schedule 40 E =90 degree standard elbow T =Tee(flow turned 90 degrees Cr =Cross (flow turned 90 degre NOTES: Calculation is for demand only. 09/26/08 "THE"Sprinkler Program 2001 File: GOIN POSTAL.the Page 1 of 1 Node Pressure Flow Hose Elevation K-factor Area Density psi gpm gpm feet gpm/(psi)Y: sqft gpm/sqft 1 30.55 452.74 1.000 Source 2 29.64 0.00 3.000 3 29.16 0.00 4.000 4 26.59 0.00 9.500 5 25.07 0.00 9.500 6 23.34 0.00 9.500 7 21.38 0.00 9.500 8 16.11 0.00 9.500 9 15.31 0.00 9.500 10 15.86 22.30 7.500 5.60 11 14.58 0.00 9.500 12 15.15 21.79 7.500 5.60 13 15.35 0.00 9.500 14 13.56 0.00 10.830 15 10.88 0.00 10.830 16 9.91 17.63 10.830 5.60 17 8.69 16.51 10.830 5.60 18 7.99 15.83 10.830 5.60 19 7.67 15.50 10.830 5.60 20 7.58 15.41 10.830 5.60 21 10.07 0.00 10.830 22 9.17 16.96 10.830 5.60 23 8.04 15.87 10.830 5.60 24 7.39 15.22 10.830 5.60 25 7.08 14.90 10.830 5.60 26 7.00 14.82 10.830 5.60 09/26/08 "THE" Sprinkler Program 2001 File: GOIN POSTAL.the Page 1 of 1 Begin End Flow Diameter Type Fittings C-Value Length Eqv Length Ttl Length Fric Loss Ttl FL Elev Loss Velocity Node Node gpm inches feet feet feet psi/ft psi psi ft/s 1 > 2 202.74 4.260 10 GV 120 2.000 2.633 4.630 0.010 0.05 0.87 4.56 2 > 3 202.74 4.260 10 GV 120 1.000 2.633 3.630 0.010 0.04 0.43 4.56 3 > 4 202.74 4.260 10 E 120 5.500 13.167 18.670 0.010 0.19 2.38 4.56 4 > 5 202.74 2.635 10 E 120 6.000 8.237 14.240 0.106 1.52 0.00 11.93 5 > 6 202.74 2.635 10 E 120 8.000 8.237 16.240 0.106 1.73 0.00 11.93 6 > 7 202.74 2.635 10 T 120 2.000 16.474 18.470 0.106 1.97 0.00 11.93 7 > 8 202.74 2.635 10 Cr 120 33.000 16.474 49.470 0.106 5.27 0.00 11.93 8 > 9 22.30 1.049 40 E 120 3.000 2.000 5.000 0.159 0.80 0.00 8.28 9 > 10 22.30 1.049 40 120 2.000 0.000 2.000 0.159 0.32 -0.87 8.28 8 > 11 21.79 1.049 40 E 120 8.000 2.000 10.000 0.152 1.52 0.00 8.09 11 > 12 21.79 1.049 40 120 2.000 0.000 2.000 0.152 0.30 -0.87 8.09 8 > 13 158.65 2.635 10 E 120 3.000 8.237 11.240 0.068 0.76 0.00 9.33 13 > 14 158.65 2.635 10 T 120 1.500 16.474 17.970 0.068 1.22 0.58 9.33 14 > 15 80.88 1.610 40 E 120 8.500 4.000 12.500 0.214 2.68 0.00 12.75 15 > 16 80.88 1.610 40 120 4.500 0.000 4.500 0.214 0.96 0.00 12.75 16 > 17 63.25 1.610 40 120 9.000 0.000 9.000 0.136 1.22 0.00 9.97 17 > 18 46.75 1.610 40 120 9.000 0.000 9.000 0.078 0.70 0.00 7.37 18 > 19 30.92 1.610 40 120 9.000 0.000 9.000 0.036 0.33 0.00 4.87 19 > 20 15.41 1.610 40 120 9.000 0.000 9.000 0.010 0.09 0.00 2.43 14 > 21 77.77 1.610 40 E 120 13.500 4.000 17.500 0.199 3.49 0.00 12.26 21 > 22 77.77 1.610 40 120 4.500 0.000 4.500 0.199 0.90 0.00 12.26 22 > 23 60.81 1.610 40 120 9.000 0.000 9.000 0.126 1.14 0.00 9.58 23 > 24 44.94 1.610 40 120 9.000 0.000 9.000 0.072 0.65 0.00 7.08 24 > 25 29.72 1.610 40 120 9.000 0.000 9.000 0.034 0.30 0.00 4.68 25 > 26 14.82 1.610 40 120 9.000 0.000 9.000 .0.009 0.08 0.00 2.33 09/26/08 "THE"Sprinkler Program 2001 File: GOIN POSTAL.the Page 1 of 3 Nozzle Flow Pipe Fittings Pipe Friction Type & in Size & Eqiv. Loss Req. Reference Location gpm inches Devices Length psi/ft psi Notes 2 q 0.00 4.260 Igth 2.000 Pt 29.64 to Q 202.74 120 GV ftg 2.633 0.010 Pf 0.05 1 Source tot 4.630 Pe 0.87 3 q 0.00 4.260 Igth 1.000 Pt 29.16 to Q 202.74 120 GV ftg 2.633 0.010 Pf 0.04 2 tot 3.630 Pe 0.43 4 q 0.00 4.260 Igth 5.500 Pt 26.59 to Q 202.74 120 E ftg 13.167 0.010 Pf 0.19 3 tot 18.670 Pe 2.38 5 q 0.00 2.635 lgth 6.000 Pt 25.07 to Q 202.74 120 E ftg 8.237 0.106 Pf 1.52 4 tot 14.240 Pe 0.00 6 q 0.00 2.635 Igth 8.000 Pt 23.34 to Q 202.74 120 E ftg 8.237 0.106 Pf 1.73 5 tot 16.240 Pe 0.00 7 q 0.00 2.635 Igth 2.000 Pt 21.38 to Q 202.74 120 T ftg 16.474 0.106 Pf 1.97 6 tot 18.470 Pe 0.00 8 q 0.00 2.635 Igth 33.000 Pt 16.11 to Q 202.74 120 Cr ftg 16.474 0.106 Pf 5.27 7 tot 49.470 Pe 0.00 9 q 0.00 1.049 Igth 3.000 Pt 15.31 to Q 22.30 120 E ftg 2.000 0.159 Pf 0.80 8 tot 5.000 Pe 0.00 10 5.60 q 22.30 1.049 Igth 2.000 Pt 15.86 to Q 22.30 120 ftg 0.000 0.159 Pf 0.32 9 tot 2.000 Pe -0.87 11 q 0.00 1.049 Igth 8.000 Pt 14.58 to Q 21.79 120 E ftg 2.000 0.152 Pf 1.52 8 tot 10.000 Pe 0.00 12 5.60 q 21.79 1.049 lgth 2.000 Pt 15.15 to Q 21.79 120 ftg 0.000 0.152 Pf 0.30 11 tot 2.000 Pe -0.87 13 q 0.00 2.635 Igth 3.000 Pt 15.35 to Q 158.65 120 E ftg 8.237 0.068 Pf 0.76 8 tot 11.240 Pe 0.00 09/26/08 "THE"Sprinkler Program 2001 File: GOIN POSTAL.the Page 2 of 3 Nozzle Flow Pipe Fittings Pipe Friction Type & in Size & Eqiv. Loss Req. Reference Location gpm inches Devices Length psi/ft psi Notes 14 q 0.00 2.635 Igth 1.500 Pt 13.56 to Q 158.65 120 T ftg 16.474 0.068 Pf 1.22 13 tot 17.970 Pe 0.58 15 q 0.00 1.610 Igth 8.500 Pt 10.88 to Q 80.88 120 E ftg 4.000 0.214 Pf 2.68 14 tot 12.500 Pe 0.00 16 5.60 q 17.63 1.610 Igth 4.500 Pt 9.91 to Q 80.88 120 ftg 0.000 0.214 Pf 0.96 15 tot 4.500 Pe 0.00 17 5.60 q 16.51 1.610 Igth 9.000 Pt 8.69 to Q 63.25 120 ftg 0.000 0.136 Pf 1.22 16 tot 9.000 Pe 0.00 18 5.60 q 15.83 1.610 Igth 9.000 Pt 7.99 to Q 46.75 120 ftg 0.000 0.078 Pf 0.70 17 tot 9.000 Pe 0.00 19 5.60 q 15.50 1.610 Igth 9.000 Pt 7.67 to Q 30.92 120 ftg 0.000 0.036 Pf 0.33 18 tot 9.000 Pe 0.00 20 5.60 q 15.41 1.610 Igth 9.000 Pt 7.58 to Q 15.41 120 ftg 0.000 0.010 Pf 0.09 19 tot 9.000 Pe 0.00 21 q 0.00 1.610 Igth 13.500 Pt 10.07 to Q 77.77 120 E ftg 4.000 0.199 Pf 3.49 14 tot 17.500 Pe 0.00 22 5.60 q 16.96 1.610 Igth 4.500 Pt 9.17 to Q 77.77 120 ftg 0.000 0.199 Pf 0.90 21 tot 4.500 Pe 0.00 23 5.60 q 15.87 1.610 Igth 9.000 Pt 8.04 to Q 60.81 120 ftg 0.000 0.126 Pf 1.14 22 tot 9.000 Pe 0.00 24 5.60 q 15.22 1.610 Igth 9.000 Pt 7.39 to Q 44.94 120 ftg 0.000 0.072 Pf 0.65 23 tot 9.000 Pe 0.00 25 5.60 q 14.90 1.610 Igth 9.000 Pt 7.08 to Q 29.72 120 ftg 0.000 0.034 Pf 0.30 24 tot 9.000 Pe 0.00 09/26/08 "THE" Sprinkler Program 2001 File: GOIN POSTAL.the Page 3 of 3 Nozzle Flow Pipe Fittings Pipe Friction Type& in Size & Eqiv. Loss Req. Reference Location gpm inches Devices Length psi/ft psi Notes 26 5.60 q 14.82 1.610 Igth 9.000 Pt 7.00 to Q 14.82 120 ftg 0.000 0.009 Pf 0.08 25 tot 9.000 Pe 0.00 Qt 452.74 Pt 30.55 09/26/08 "THE"Sprinkler Program 2001 as�o 0 d s a cn u. a� m a pp pp pp o p pp pp po o p pp pp N tp to M N Q S 61 a0 fO lf) e M N O (isd)ainssald